CEILING CONCEALED SPLIT SYSTEM C SERIES
|
|
- Catherine Elliott
- 6 years ago
- Views:
Transcription
1 CEILING CONCEALED SPLIT SYSTEM C SERIES
2 Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user. In addition, its control algorithms can provide protection to components of the air conditioning unit against any faults. Auto Random Restart During occasion of power failure, the unit will automatically restart according to the last setting condition when power resumed. Option is provided to cancel this feature. Double Protection Drainage System The primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan built in to the standard unit offers extra protection against possible water leaking problems. Primary Drain Pan Polysterene (Ps) ith Height Impact Polystyrene (Hips) Cover Secondary Drain Pan ith Insulation FEATURES Flexibility In System Design The unit offers fan motor that can operate up to 4 speeds (Models A5CC 28C & above only), thus provide choices of external static pressure for designing ducting system. In addition, a range of ACCC model with optional specification of low external static pressure is also provided to cater for short duct application. Please refer to the technical specification of ACC model. Self Diagnosis Features The microprocessor provides the possibility to detect and to diagnose any faults that occur in the system. Faults are displayed as error code in the wired controller. This will ease the troubleshooting process. Duct Accessories (Optional) A set duct accessories specifically designed to fit and to suit the ACCC model is being created. Thus offers a one stop solution to installing the unit. * Available for ACC 1025 C/CR only Flexible Round Duct (field supply) Discharge Adaptor Square Grille Assembly c/w Adaptor Secondary Drain Pan with Insulation Ceiling Concealed Unit Square Return Grille Assembly c/w Adaptor & Filter Primary Drain Pan ACC Return Assembly Bracket c/w Adaptor Flexible Round Duct (field supply)
3 NIM Able The ACC range of product is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a system of multiple indoor units in a building. Choices Of ired And ireless Controller SLM 3 AC5300 ireless Controller (Optional) Netare III Controller (Optional) Standard units come with a simple and user friendly SLM 3. An optional specification of ACCC series is also available that comes with Netware III, which offers wide range of control features that includes 7 days and 24 hours timer settings, self diagnosis error code display and more. In addition, an innovative and compact wireless controller (credit card size), AC5300, provides wireless command to the SLM 3 & NETARE III. R410A Refrigerant In line with Montreal Protocol A5CC series utilise the new R410A refrigerant. 50%R32 50%R125 Better Air Distribution The conditioned air can be effectively distributed to the room through the ducting and this ensures a pleasant environment for comfortable living. Multiple rooms can be cooled together at the same time by using just one unit of fan coil.
4 CEILING CONCEALED ACCC SERIES R22 HEAT PUMP MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY ACC 10CR ACC 15CR ACC 20CR ACC 25CR ALC 10CR ALC 15CR ALC 18CR ALC 20CR ALC 25CR NOMINAL TOTAL INPUT POER COOLING (STANDARD) HEATING NOMINAL TOTAL INPUT POER COOLING (LO STATIC) HEATING EER (STANDARD) / COP (STANDARD) / EER (LO STATIC) / COP (LO STATIC) / NOMINAL CAPACITY ACC 10C ACC 15C ACC 20C ACC 25C ALC 10C ALC 15C ALC 18C ALC 20C ALC 25C NOMINAL TOTAL INPUT POER (STANDARD) NOMINAL TOTAL INPUT POER (LO STATIC) EER (STANDARD) / EER (LO STATIC) / POER SOURCE V/Ph/Hz / 1 / / 1 / / 1 / / 1 / 50 HIGH 142 / / / / 810 AIR FLO MEDIUM 123 / / / / 760 LO 104 / / / / 610 HIGH 142 / / / / / 770 AIR FLO MEDIUM 118 / / / / / 720 (LO STATIC) LO 99 / / / / / 580 EXTERNAL STATIC PRESSURE (H/M/L) 49 / 39 / / 39 / / 65 / / 31 / 18 (0.20 / 0.16 / 0.12) (0.20 / 0.16 / 0.08) (0.28 / 0.26 / 0.17) (0.16 / 0.12 / 0.07) EXTERNAL STATIC PRESSURE (LO STATIC, H/M/L) 20 / 9.8 / 4.9 (0.08 / 0.04 / 0.02) 29 / 20 / 9.8 (0.12 / 0.08 / 0.04) 25 / 15 / 5 (0.10 / 0.06 / 0.02) SOUND PRESSURE LEVEL (H/M/L) dba 33 / 30 / / 34 / / 36 / / 36 / / 39 / 36 HEIGHT 261 / / / / IDTH 765 / / / / / / / / EIGHT kg/lb 17 / / / / / 55.1 SOUND PRESSURE LEVEL dba HEIGHT 540 / / / 29.8 IDTH 700 / / / / / / 12.9 UNIT EIGHT kg/lb 32 / / / / LIQUID 6.35 / 1/ / 1/ / 1/ / 1/ / 3/8 GAS 9.52 / 3/ / 1/ / 5/ / 5/8 HEAT PUMP MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 60HZ NOMINAL TOTAL INPUT POER (STANDARD) 1Ø <3Ø> NOMINAL TOTAL INPUT POER (LO STATIC) 1Ø <3Ø> EER (STANDARD) 1Ø <3Ø> COP (STANDARD) 1Ø <3Ø> EER (LO STATIC) 1Ø <3Ø> COP (LO STATIC) 1Ø <3Ø> NOMINAL TOTAL INPUT POER 1Ø <3Ø> EER 1Ø <3Ø> COP 1Ø <3Ø> NOMINAL CAPACITY 60HZ NOMINAL TOTAL INPUT POER (STANDARD) 1Ø <3Ø> NOMINAL TOTAL INPUT POER (LO STATIC) 1Ø <3Ø> EER (STANDARD) 1Ø <3Ø> EER (LO STATIC) 1Ø <3Ø> NOMINAL TOTAL INPUT POER 1Ø <3Ø> EER 1Ø <3Ø> POER SOURCE 1Ø <3Ø> AIR FLO AIR FLO (LO STATIC) ACC 28CR ACC 30CR ALC 28CR ALC 30CR ALC 28CR ALC 30CR COOLING <3070> <3125> HEATING <3040> <3095> COOLING <3096> HEATING <3066> / <2.86> <3.02> / <2.99> <3.06> / <2.89> / <2.92> COOLING HEATING / / ACC 28C ACC 30C ALC 28C ALC 30C ALC 28C ALC 30C <2981> < 2855 > <2826> / <2.85> < 3.22 > / <3.06> / V/Ph/Hz / 1 / 50 < / 3 / 50> SUPER HIGH 401 / / 900 HIGH 382 / / 830 MEDIUM 363 / / 760 LO 335 / / 710 SUPER HIGH 444 / 940 HIGH 415 / 880 MEDIUM 373 / 790 LO 349 / 740 EXTERNAL STATIC PRESSURE (H/M/L) 98 / 78 / 68 / 59 (0.39 / 0.31 / 0.28 / 0.24) 206 / 167 / 127 / 88 (0.83 / 0.67 / 0.51 / 0.35) EXTERNAL STATIC PRESSURE (LO STATIC, H/M/L) 49 / 39 / 29 / 20 (0.20 / 0.16 / 0.12 / 0.08) SOUND PRESSURE LEVEL (H/M/L) dba 44 / 41 / 38 / / 46 / 42 / 38 HEIGHT 285 / IDTH 1007 / / / / EIGHT kg/lb 38 / / 86.0 SOUND PRESSURE LEVEL dba HEIGHT 756 / / 29.8 IDTH 855 / / / / / / UNIT EIGHT kg/lb 65 / / / / LIQUID GAS 9.52 / 3/ / 3/ / 5/ / 5/8 ACC 38CR ALC 35CR ALC 40CR <3736> <3436> <3.21> <3.55> ACC 38C ALC 35C ALC 40C < 3656 > < 3.03 > / / / / / 118 / 108 / 88 (0.55 / 0.47 / 0.43 / 0.35) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO ) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/COP CALCULATION IS BASED ON EFFECTIVE POER INPUT AS PER ISO / 51 / 48 / / / / / / / / / 3/ / 3/4
5 CEILING CONCEALED ACCC SERIES R22 HEAT PUMP MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY ACC 40CR ACC 50CR ACC 60CR ALC 35CR ALC 40CR ALC 50CR ALC 61CR NOMINAL TOTAL INPUT POER COOLING <3698> <5047> <6010> (STANDARD) 1Ø <3Ø> HEATING <3408> <4447> <4980> NOMINAL TOTAL INPUT POER COOLING <3643> (LO STATIC) 1Ø <3Ø> HEATING <3153> EER (STANDARD) 1Ø <3Ø> / <3.44> <3.11> <2.91> COP (STANDARD) 1Ø <3Ø> / <3.76> <3.78> <3.57> EER (LO STATIC) 1Ø <3Ø> / <3.28> COP (LO STATIC) 1Ø <3Ø> / <3.57> NOMINAL TOTAL INPUT POER COOLING Ø <3Ø> HEATING EER 1Ø <3Ø> / COP 1Ø <3Ø> / NOMINAL CAPACITY ACC 40C ACC 50C ACC 60C ALC 35C ALC 40C ALC 50C ALC 61C NOMINAL TOTAL INPUT POER (STANDARD) 1Ø <3Ø> < 3505 > < 4974 > < 6006 > NOMINAL TOTAL INPUT POER (LO STATIC) 1Ø <3Ø> <3450> EER (STANDARD) 1Ø <3Ø> / < 3.51 > < 2.97 > <2.92> EER (LO STATIC) 1Ø <3Ø> / <3.33> < 2.9 > < 2.85 > NOMINAL TOTAL INPUT POER 1Ø <3Ø> EER 1Ø <3Ø> / POER SOURCE 1Ø <3Ø> SUPER HIGH V/Ph/Hz 519 / / 1 / 50 < / 3 / 50> 750 / / 1650 AIR FLO HIGH 500 / / / 1530 MEDIUM 467 / / / 1430 AIR FLO (LO STATIC) LO SUPER HIGH HIGH MEDIUM LO 425 / / / / / / / / / / / / / / / HZ 60 HZ EXTERNAL STATIC PRESSURE (H/M/L) EXTERNAL STATIC PRESSURE (LO STATIC, H/M/L) 206 / 176 / 127 / 93 (0.83 / 0.71 / 0.51 / 0.37) 49 / 39 / 29 / 20 (0.20 / 0.16 / 0.12 / 0.08) SOUND PRESSURE LEVEL (H/M/L) dba 51 / 49 / 45 / / 52 / 50 / / 53 / 50 / 47 EIGHT HEIGHT IDTH kg/lb 1045 / / / / / / / / / SOUND PRESSURE LEVEL dba HEIGHT IDTH 400 / / / 18.1 UNIT EIGHT kg/lb 95 / / / / LIQUID 9.52 / 3/ / 3/ / 1/2 GAS / 3/ / 3/ / 3/4 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO ) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. 176 / 157 / 137 / 108 (0.71 / 0.63 / 0.55 / 0.43) 78 / 59 / 39 / 20 (0.31 / 0.24 / 0.16 / 0.08) 176 / 157 / 137 / 98 (0.71 / 0.63 / 0.55 / 0.39) 69 / 49 / 29 / 20 (0.28 / 0.20 / 0.12 / 0.08)
6 CEILING CONCEALED A5CCC SERIES R410A HEATPUMP MODEL NOMINAL COOLING CAPACITY 1Ø <3Ø> NOMINAL HEATING CAPACITY 1Ø <3Ø> A5CC 10CR A5CC 15CR A5CC 20CR <18000> <18500> A5CC 25CR <22860> <23200> A5LC 10CR A5LC 15CR A5LC 20CR 5280 <5280> 5420 <5420> A5LC 25CR 6155 <6700> 6450 <6800> NOMINAL TOTAL INPUT POER COOLING <1791> 2003 <2274> 1Ø <3Ø> HEATING <1561> 1953 <2167> EER 1Ø <3Ø> / <3.07> 3.15 <3.02> COP 1Ø <3Ø> / <3.64> 3.39 <3.22> A5CC 25C A5LC 25C NOMINAL CAPACITY 1Ø <3Ø> A5CC 10C A5CC 15C A5CC 20C A5LC 10C A5LC 15C A5LC 20C <18000> <5280> <1791> / <3.07> <22860> 6155 <6700> NOMINAL TOTAL INPUT POER 1Ø <3Ø> 2003 <2274> EER 1Ø <3Ø> 3.15 <3.02> POER SOURCE 1Ø <3Ø> V/Ph/Hz / 1 / /1/50 <380415/3/50> HIGH 142 / / / / 730 AIR FLO MEDIUM 123 / / / / 720 LO 104 / / / / 580 EXTERNAL STATIC PRESSURE (H/M/L) 49 / 39 / 29 (0.20 / 0.16 / 0.12) 49 / 39 / 20 (0.20 / 0.16 / 0.08) 64 / 58 / 34 (0.30 / 0.20 / 0.10) 55 / 39 / 29 (0.20 / 0.20 / 0.10) SOUND PRESSURE LEVEL (H/M/L) dba 33 / 30 / / 34 / / 36 / / 39 / 36 HEIGHT 261 / / / / IDTH 765 / / / / / / / / EIGHT kg/lb 17 / / / / 55.1 SOUND PRESSURE LEVEL dba HEIGHT 540 / / / 29.8 IDTH 700 / / / / / / 12.9 UNIT EIGHT kg/lb 32 / / / LIQUID 6.35 / 1/ / 1/ / 1/ / 1/4 GAS 9.52 / 3/ / 1/ / 1/ / 5/8 HEATPUMP MODEL NOMINAL COOLING CAPACITY 1Ø <3Ø> NOMINAL HEATING CAPACITY 1Ø <3Ø> A5CC 28CR <27000> <28000> A5CC 38CR <33000> <36000> <39000> <42000> A5CC 50CR <48000> <49000> A5CC 60CR <54500> <57000> A5LC 28CR 7620 <7910> 7620 <8210> A5LC 35CR 9380 <9670> 9960 <10550> A5LC 40CR <11430> <12310> A5LC 50CR <14070> <14360> A5LC 61CR <15970> <16710> NOMINAL TOTAL INPUT POER COOLING 2892 <2876> 3287 <3427> <4173> <5115> <5765> 1Ø <3Ø> HEATING 2429 <2528> 2987 <3137> <4203> <4535> <5685> EER 1Ø <3Ø> / 2.73 <2.85> 3.07 <3.03> <2.88> <2.94> <2.98> COP 1Ø <3Ø> / 3.27 <3.38> 3.62 <3.64> <3.08> <3.42> <3.16> NOMINAL CAPACITY 1Ø <3Ø> A5CC 28C A5CC 38C A5CC 50C A5CC 60C A5LC 28C A5LC 35C A5LC 40C A5LC 50C A5LC 61C <27000> <33000> <39000> <48000> <54500> 7620 <7910> 9380 <9670> <11430> <14070> <15970> NOMINAL TOTAL INPUT POER 1Ø <3Ø> 2892 <2876> 3287 <3427> <4173> <5115> <5765> EER 1Ø <3Ø> / 2.73 <2.85> 3.07 <3.03> <2.88> <2.94> <2.98> POER SOURCE 1Ø <3Ø> V/Ph/Hz /1/50 <380415/3/50> SUPER HIGH 401 / / / / 1720 AIR FLO HIGH 382 / / / / 1550 MEDIUM 363 / / / / 1340 LO 335 / / / / 1170 EXTERNAL STATIC PRESSURE (SH/H/M/L) 98 / 78 / 68 / 59 (0.39 / 0.31 / 0.28 / 0.24) 118 / 96 / 78 / 61 (0.47 / 0.39 / 0.31 / 0.24) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO ) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/COP CALCULATION IS BASED ON EFFECTIVE POER INPUT AS PER ISO / 126 / 109 / / 120 / 90 / 69 (0.59 / 0.50 / 0.44 / 0.37) (0.59 / 0.48 / 0.36 / 0.28) SOUND PRESSURE LEVEL (SH/H/M/L) dba 44 / 41 / 38 / / 49 / 48 / / 53 / 52 / / 52 / 50 / 46 HEIGHT 285 / / / / 14.9 IDTH 1007 / / / / / / / / 21.3 EIGHT kg/lb 38 / / / / 137 SOUND PRESSURE LEVEL dba HEIGHT 756 / 29.8 IDTH 855 / / / / / 18.1 UNIT EIGHT kg/lb 68 / / / / / LIQUID 9.52 / 3/ / 3/ / 3/ / 3/8 GAS / 5/ / 5/ / 5/ / 3/ Acson International APACCC09
Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential)
MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular
More informationAll Product Catalogue
All Product Catalogue AP-MIY-12 Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information,
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP
VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationAll Product Catalogue
All Product Catalogue AP-MIY-10 Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information,
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationmodular multi intelligent, environmental and versatile
modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor
More informationModels: 12 and 18. Models: 24 to 60
SPLIT CASSETTE TYPE MUCSR-H8 Series SCOP 4.0 Models: 12 and 18 RG57B2/BGE Included (CL 94 982) Models: 24 to 60 Design 360 Thanks to the 360 panel design, the air is more evenly distributed. Drainage pump
More informationDriving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan
Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse
More informationOthers ( 50Hz areas ) ADVANCED SUBJECT DATE: Sep 12 PRODUCT NEWS Launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series.
PRODUCT S Launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series. PAGE 1/7 Suary This Advanced Products News introduces the launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series driven
More informationDUCTED INDOOR UNIT ENGINEERING MANUAL
EM_MultiV_Ducted_IndoorUnits_4_16 DUCTED INDOOR UNIT ENGINEERING MANUAL High Static Ducted 7,500 to 95,900 Btu/h Low Static Ducted 7,500 to 24,000 Btu/h Low Static Built In Ducted 7,500 to 24,200 Btu/h
More informationAesthetically Attractive Indoor unit. Enhanced with various Indoor Air Quality Features. Negative Ion Generator (Standard)
MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular
More informationCompact Four-way Cassette Type
1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...
More informationIt is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.
Concealed Ceiling It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Inner groove copper ashable filter Quiet function Multi fan speed
More informationHitachi Multizone Heat Pump Air Conditioning
Cooling 1.5 13.2 Heating 1.5 14.4 Hitachi Heat Pump Air Conditioning Giving you complete control Zone control that s fast, efficient and clean Imagine being able to rapidly adjust the comfort levels in
More informationM1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT
VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility
More informationFour-Way Ceiling Cassette
Benefits of Multi F Systems Individual zone control Operating ranges of 14 F to 118 F in cooling and 0 F to 64 F in heating Quiet and comfortable environment Safer and easier installation with Cost efficient
More informationStylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a
Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationLow Static Pressure Duct (V shape evaporator)
MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...
More informationRooftop Packaged Air Conditioners
Catalog Rooftop Packaged Air Conditioners Models: MRT 055 A/AR MRT 060 A/AR MRT 080 A/AR MRT 100 A/AR MRT 120 A/AR MRT 150 A/AR MRT 200 A/AR MRT 250 A/AR MRT 300 A/AR MRT 360 A/AR MRT 420 A/AR M4RT M4RT
More informationPREMIUM INVERTER DUCTED AIR CONDITIONING
PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic
More informationHigh Static Pressure Duct Fan Coil Unit
MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4
More informationLandmark Rooftop Packaged Units
Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS...................... 1 DIMENSIONS..........................
More informationVMDA Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the
More informationModel RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2
2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit
More informationDigital Inverter 4 series
TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationIndoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.
Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationInverter Series [ INVERTER ] All Product Brochure
Inverter Series [ INVERTER ] All Product Brochure About Acson International ith products available in more than 55 countries spread across 7 continents around the world, Acson is truly international. Backed
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationSTELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES
(1295) STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES - 12.00 SEER S E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION These high efficiency EFH Series heat pump units are the outdoor
More informationSINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)
SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s
More informationAmendment Sheet. Code : ADB-FR Date : Superceded : nil REFRIGERANT CIRCUIT DIAGRAM
mendment Sheet Code : DB-FR-007-0001 Date : 18-0-008 Superceded : nil REFRIGERNT CIRCUIT DIGRM GENERL DT HETPUMP (R) NOMINL COOLING CPCITY NOMINL HETING CPCITY NOMINL TOTL INPUT POER (COOLING) NOMINL TOTL
More informationGuide Specifications. General. Casing. Coil/Drain pan. Fan/Motor
Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series
More informationHELV NEUE BD CN 90% 51pts
HELV NEUE BD CN 90% 51pts CONTURA FG HIGH-WALL Mini-split Air Conditioners High-Wall Series 9,000-28,000 Btu/h (New) MCW and MWW Series 50/60Hz R22/R410A CONTURA FG HIGH-WALL New Look, New Experience TRANE
More informationRCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.
RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationService manual MIV V4+ Indoor units
Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationFULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationEngineering Data Book
40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationAHN 064 to 304 EHN/CHN 064 to 304
u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description
More informationLG Multi Split Air Conditioners
AUS-MUF111 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 266 PH : 02-8805-4000 FAX : 02-8805- Queensland 23 Terrace Place MURARRIE QLD 4 PH : 0-8-000 FAX : 0--41 Victoria 3 John Deere
More informationSPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................
More informationVRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***
VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature
More informationFour steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology
Slim Ducted Systems Two choices of selection for the air inlet flow Natural drain discharge port and drain pump (up to 850 mm) Cleanable pre-filter included Slim Ducted Systems Digital Inverter Four steps
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationDC INVERTER VRF SYSTEMS C-VRF
DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More information13 SEER Light Commercial 3 Phase
13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationRPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.
RPGE13 Product Specifications 13 SEER Gas / Electric Residential Packaged Unit Form No. RPGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin
More informationRPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.
RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit
More informationFan Coil Unit Product Catalogue
AP-FCU-1 Chilled ater PRODUCT SYSTM all Mounted Cassette Ducted Fan Coil Unit Product Catalogue Products manufactured in an ISO certified facility. This document contains the most current product information
More informationVRF. Technical Data Book. Duct S for Europe (R410, 50Hz)
VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data
More informationAIR CONDITIONING Managing condensate
www.sauermann.co.uk AIR CONDITIONING Managing condensate Pump selection chart Equipement Location Wall mounted Cassette Multi cassette Conditioning cabinet ALTEZZA DI MANDATA (m) Floor standing Ducted
More informationMultizone Multi Split systems
19 Multizone Multi Split systems Features and Benefits 2 Room 3 Room 4 Room 5 Room 6 Room RAM-36NP2A RAM-53NP2A RAM-53NP3A RAM-68NP3A RAM-70NP4A RAM-90NP5A RAM-130NP6A Nominal Cooling Capacity (kw) 3.6
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application September 2014 Ductless Split s Right Product for the Right Application Single-Zone s Multi-Zone s (up to five rooms) High Wall High Wall, Cassette,
More informationPRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER
PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge
More information40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw
LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs
More informationFour-way Cassette Type
Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...
More informationSplit-Sky Air FDYP-B7 Concealed Ceiling Unit
TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the
More information13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.
13 SEER Light Commercial 3 Phase Packaged Heat Pump RHP13 Features and Benefits Form No. AC-RHP13-100 (05/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationPHCD-Series. Catalog
PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,
More informationPCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A
PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A An industry first, the VRV air handling unit has been designed and engineered
More informationContents. Carrier China
42CE Fan Coil Unit Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration solutions, with operations
More information(Thin) (Ultrathin) Suspended Air-handling Unit
(Thin) (Ultrathin) Suspended Air-handling Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 High Wall High Wall, Cassette, Underceiling 2:1 to 5:1 High Wall Up to 23.0
More informationV33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has
More informationPRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES
PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports
More informationFrom domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.
PRODUCT RANGE PRODUCT Contents RANGE Wall Hung Split Systems Variable Capacity Pages 4- Split Ducted Standard Cycling Pages 6-11 The ActronAir range of air conditioners provides a solution for most applications.
More informationindoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS
indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS HRE-TOP EC Non-residential ventilator unit ith dual flo and high
More informationChilled Water Vertical Fan Coils
PRODUCT MANUAL Chilled Water Vertical Fan Coils Models: FWMW-C FWMW-H FWCW-C FWCW-H INDEX Vertical Fan Coil page 2 General Characteristics page 3 Technical data page 7 Sound Level page 9 Operating Limits
More informationCOMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS
2010 COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS COMMERCIAL WELCOME TO COMMERCIAL RANGE Welcome to Commercial range. Welcome to healthier air. A range which confi rms its commitment
More informationGQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY
TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged
More informationProduct Brochure 2018
Product Brochure 2018 2018 Brand Story - 2 - HEALTH Air Filter COMFORT Auto mode heating or cooling. and other materials. Wi-Fi Control Compatible to the Internet Evaporator self-cleaning ENERGY DRED Soft
More informationProduct Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES
Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a
More informationMODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si
MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si Part 1 General Information.. 1 Part 2 Indoor Units. Part 3 Outdoor Units. Part 5 Control... Part 6 Control
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationPRAC14 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service
More information2010 Duct-Free Splits Line Card
2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette,
More informationDuctless Systems. Right product for the right application. Fall 2015 Edition
Ductless Systems Right product for the right application Fall 2015 Edition Right Product for the Right Application Single Zone - Residential Single Zone - Light Commercial Multi-Zone RAV-**KRT System High
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationHigh Wall Type ( 2 Series )
Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle
More information