Special Purpose Fuses

Size: px
Start display at page:

Download "Special Purpose Fuses"

Transcription

1 Multimeter and metering fuses DC fuses, fuse bases and disconnectors Mining fuses Safe Work Fuses Power Capacitor Fuses Fuses for TVSS products protection Fuses for railway applications Battery Protection Fuses Fuel Cell Protection Fuses PROTECTION OF SPECIAL APPLICATIONS POWER NEEDS CONTROL

2 Contents MULTIMETER Fuse Links CH gr SE (SPECIAL EDITION) Fuse Link gg NV/NH 00V a.c. metering Fuse Link gtr NV/NH 00V a.c. metering DC Fuses: NH DC 80 V - Telecom fuse NH DC 50 V NH DC 0 V NH DC 00 V ar NV Telecom fuse disconnectors Fuse base PK00 00V a.c. M8-M8 Fuse base PK1 and PK3 DC Fuse base U1-1 00V Fuse base PK XL Fuse disconnector TL1-1/9/00V Mining Fuses: Fuse-link am NV/NH 00V a.c. Fuse-link gb NV/NH 00 00V a.c. Fuse-link gg NV/NH 0 V a.c. Safe work Fuses Power capacitor fuse Fuses for TVSS products protection: CH SRF class II CH SRF 5kA class I CH SRF class II - DC Fuses for railway applications: NH1S/39/DC 000V ar-fuse link NH S/39/ DC 000V ar - fuse link NH1/350/DC 000V ar-fuse link NH1/130/DC 00V gr - fuse link Fuses for high-voltage switchgear Battery Protection Fuses: CH x38 BATTERY Fuse link 550V d.c. CH x38 BATTERY Fuse link 800V d.c. CH 1x51 BATTERY Fuse link 800V d.c. NH BATTERY fuse link 80V d.c. Fuses for protection of forklift batteries TRB NH BATTERY fuse link 550V d.c. NH BATTERY fuse link 700V d.c. NH BATTERY fuse link 800V d.c. Fuel Cell Fuses

3 MULTIMETER Fuse Links 00V a.c./d.c. Breaking capacity 30kA a.c./d.c. Characteristics gr Standards IEC 09-, UL 8-1,UL 8-13 UL certificate Nr. E33 Multimeter fused CH MULTI Size x38 Code No. standard indicator Power [W] , , , ,8 0050, , , ,15 Packaging [g] /500 FUSED 5

4 CH gr SE (SPECIAL EDITION) 90V a.c. Breaking capacity 0kA AC Characteristic gr, according to IEC 09- Fuses are fast acting, full range. Used in protection of the inverters, variable speed drives. Excellent cycling load capability ( current cycling test). CH x38gr SE 90V Size x38 Code Number standard contacts Code Number type SU contacts Pre-arcing Joule integral [A s] L/R=ms Operating Joule integral [A s] L/R=ms Power [0,8 x ] P d [W] Power [1x ] P d [W] Packaging ,,8 / ,7,9 SU:/380 [g] /1 Simulating current of motor start current cycle test at T amb = 70 0 C IN =,5A Max. permissible motor rated current Standard Contacts Type SU Contacts

5 Fuse Link gg NV/NH 00V a.c. metering 00V a.c. Breaking capacity 50kA a.c. Standards IEC EN 09-1 Characteristic gg As metering fuse with strip fuse switch disconnector and fuse switch disconnetor NV/NH 00V a.c. Size 1 3 a standard indicator Power [W] , , , , , , Packaging [g] 1/ 500 1/1 00 1/

6 Fuse Link gtr NV/NH 00V a.c. metering 00V a.c. Breaking capacity 5kA a.c. Standards IEC EN 09-1 Characteristic gtr As metering fuse with strip fuse switch disconnector and fuse switch Aplication disconnector NV/NH 00V a.c. Size 1 3 a Nominal transformer power [kva] standard indicator Power [W] Packaging [g] 1/ 500 1/1 00 1/ Size dimensions [mm] a1 b1 c1 e1 G H a a a

7 Telecom Fuses FUSES FOR DC (Direct Current) APPLICATIONS - ETI solution for TELECOM Power Supply Circuits ETI d.d. developed specially designed fuse-iinks for short circuit protection of d.c. telecom power supplies. They are typically installed into rectifier outputs, battery feeders or d.c.power distribution for protection of the load circuits. All their characteristics are optimized to correspond to the operating conditions of telecom power supply equipment. Power s and switching voltage provide optimal function and protection of telecom power supplies. The ETI TELECOM NH00 fuse-iink is a high breaking capacity current Iimiting fuse-iink with pure silver, age-resistant melting element. NH DC 80 V - Telecom fuse 80 V d.c. (L/R = 0 ms) Breaking capacity 5 ka d.c. Standards IEC 09-1 Fuse-link for battery and UPS protection. NH DC 80 V - Telecom fuse Size 00 standard indicator Code No. striker indicator Power [W] , , , , , ,5 Time-current characteristics Packaging [g] 3/ Pre-arcing time [s] t v /s 3 50 A 00 A A 30 A 800 A 8, ,8-3 Prospective current I p /A 5 9

8 NH DC 50 V 50 V d.c. (L/R = 0 ms) Breaking capacity 5 ka d.c. Standards IEC 09- Fuse-link for DC application. NH DC 50 V Size 00 standard indicator Code No. striker indicator Power [W] , , , , , ,0 Packaging [g] , ,

9 NH DC 0 V 0 V d.c. (L/R = 0 ms) Breaking capacity 50 ka d.c. Standards IEC 09- Fuse-link for DC application. NH DC 0 V Code No. 00 C 00 1 C 1 Size Max. power [W] Packaging [g] C 7, 3/ ,1 3/ C 1,9 3/ ,3 3/ C B A Time-current characteristics D E H 9,8 K F G type dimensions [mm] A B C D E F G H K 00 C , C Pre-arcing time [s] t v /s 3 5 A 0 A 3 A 80 A 0 A 3 A 50 A 0 A 15 A 00 A 50 A A Prospective current I p /A 11

10 NH DC 00 V ar 00V d.c. (L/R=1ms) Breaking capacity 30 ka d.c. Standards IEC 09- Fuse-link for DC application. NH DC 00 V ar Size 3L Type with center trip indicator for microswitch MK Power [W] Pre-arcing Joule integral (I t) L/R=1ms Operating Joule integral (I t) L/R=1ms Packaging [g] Time-current characteristics M Pre-arcing time (s) tv/s 3 800A 150A 00A Prospective current (A) Ip/A 1

11 NV Telecom fuse disconnectors NV Telecom fuse disconnectors type Code No. HVL 00 Telecom 1P M1-M1, front connection, for striker HVL 00 Telecom 1P M1-M1, rear connection, for striker HVL 00 Telecom 1P M1-M1, front connection 0019 HVL 00 Telecom 1P M1-M1, rear connection Technical data for NV Telecom fuse disconnectors Technical Specifications HVL 00 Electrical Characteristics Rated conditional short-circuit current - ka eff 50 Utilization category I e A DC 0-B/800 A Rated impulse withstand voltage U imp kv 8 Operating cycles with current Total power loss at I th (without TM) O v W Fuse links Size to DIN Max. rated current (gg) A 800 Mechanical characteristics Operating cycles without current kg 0,75 Cable connection Flat terminal Bolt diameter - - s. drawings Cable lug (DIN 30) - mm 0 Flat bar - mm 30x Tightening torque M a Nm Type of protection Front side Operational state - - IP 0 Device fitted Front cover open - - IP Operating conditions Ambient temperature T u O C -5 to +55 Rated operating mode - - Continuous operation Actuation - - dependent manual operation Mounting position - - vertical, horizontal Altitude - m up to 000 Pollution degree Overvoltage category - III 13

12 Ø7 xø7 0 8 M1x M1x5 Fuse base PK00 00V a.c. M8-M8 00V a.c. Rated current A Insulation class C-VDE 01 Standards EN 09, IEC 09, DIN VDE 03, DIN 30, DIN 33 Fuse base PK00 00V M8-M8 Type Code No. [g] Packaging PK00 00Va.c. M8-M / Dimensions [mm] Type A B C D E F H I J K M O PK00 00V M8-M ,5 M8 7,5 30 5, ,5 1

13 Fuse base PK1, PK and PK3 DC 00V d.c. Rated current 50A, 00A Insulation class C-VDE 01 Standards EN 09, IEC 09, DIN VDE 03, DIN 30, DIN 33 Fuse base PK Type Code No. [g] Packaging PK1 DC / PK DC /30 PK3 DC / PK1, 3 DC PK DC Dimensions [mm] Type A B C D E F G H I J K M PK1 DC M Ø, PK3 DC 80 1 M1 Ø,

14 Fuse base U1-1 00V Rated current Conv. free air thermal current with fuse-links Conv. free air thermal current with solid links Max. permis. power per fuse-link Cable terminal - Flat terminal Screw Cable lug (DIN 35) Flat termination Rated torque 00V d.c. A A 35A 31W M mm 30x mmx-mm Nm Fuse base U1-1 00V Type Code No. Max. Connection (mm ) [g] Packaging U1-1 00V

15 Fuse base PK XL 0V a.c./d.c. Rated current 50A, 00A, 30A Insulation class C-VDE 01 Standards EN 09, IEC09, DIN VDE 03, DIN 30, DIN 33 Fuse base PK XL Type Code No. PK1 XL PK XL PK3 L NEW! Fuse base PKI XL - insulated contact Type Code No. PKI1 XL PKI XL PKI3 L Used only in combination with ETI fuse links! 5,5 30 1,5,5 Dimensions [mm] Size A B C D E H J K L M PK1XL M PKXL 0 M PK3L 70 M

16 Fuse disconnector TL1-1/9/00V Number of poles 1 00V d.c. Rated current A Conv. free air thermal current with fuse-links A Utilization category DC-0B Fuse-links Size to DIN 30 1 Max. rated current (gl/gg) A Max. permis. power loss per fuse-link 5W Cable terminal - Flat terminal Screw M Cable lug (DIN 35) 5-0 mm Flat termination 30x mm Rated torque Nm Type of protection - front side, device fitted IP0, IP Operating conditions Ambient temperature* -5 to +55 Rated operating mode Cont. operation Actuation Dependent manual actuation Mounting position Vertical, horizontal Altitude up to 000 m Pollution degree 3 Overvoltage category III *35 0 C normal temperature, 55 0 C with reduced operating current Fuse disconnector TL1-1/9/00V Type Code No. Max. Connection (mm ) Terminal [g] Packaging TL1-1/9/00V M , Ø.,5 Ø.,

17 Fuse-link am NV/NH 00V a.c. 00V a.c. Breaking capacity 5kA a.c. Standards VDE Characteristic am For equipment protection in mining industry. For relays, contactors and motors protection in case of short-circuit. 00V a.c. am Size 00 Standard indicator Pre-arcing Joule integral [A s] Operating Joule integral [A s] at 35V Operating Joule integral [A s] at 10V Power [W] , C 9,8 [g] Packaging 350 3/5 H E D G B A K F Dimensions [mm] Size A B C D E F G H K

18 Time-current characteristics Pre-arcing time (s) tv/s I0/A -1 - Cut-off characteristics 5 3 Prospective current (A) Ip/A A 15A 0A 80A 3A 50A 0A/35A 3A 5A Prospective fault current Ip/A 0

19 Fuse-link am NV/NH 00V a.c. 00V a.c. Breaking capacity 5kA a.c. Standards VDE Characteristic am For equipment protection in mining industry. For relays, contactors and motors protection in case of short-circuit. 00V a.c. am Size 1 3 Standard indicator Pre-arcing Joule integral [A s] Operating Joule integral [A s] at 35V Operating Joule integral [A s] at 10V Power [W] C 9,8 [g] Packaging 530 1/8 00 1/8 H E D G B A K F Dimensions [mm] Size A B C D E F G H K

20 Time-current characteristics Pre-arcing time (s) tv/s 3 3A 50A 0A 80A 50A 00A A 15A 00A 315A 500A I0/A Cut-off characteristics 5 3 Prospective current (A) Ip/A Ik Ik 500A 00A 315A 50A 00A 15A 0A 80A 3A 50A A Prospective fault current Ip/A

21 Fuse-link gb NV/NH 00 00V a.c. 00V a.c. Breaking capacity 5kA a.c. Standards VDE Characteristic gb For equipment protection in mining industry. NV/NH gb 00V a.c. Size 00 Standard indicator Pre-arcing Joule integral [A s] Operating Joule integral [A s] at 35V Operating Joule integral [A s] at 10V Power [W] C 9,8 [g] Packaging 350 3/5 H E D G B A K F Dimensions [mm] Size A B C D E F G H K

22 Time-current characteristics Pre-arcing time (s) tv/s A 0A 35A 3A 5A 3A 80A 0A 15A I0/A Prospective current (A) Ip/A C ut-off characteristics Ik Ik 15A 0A 80A 3A 50A 35/0A 3A 5A Prospective fault current Ip/A

23 Fuse-link gg NV/NH 0 V a.c. 0V a.c. Breaking capacity 50 ka a.c. Standards IEC 09 Characteristic gg 0V a.c. gg Size 1XL XL 3L Standard indicator (pic.1) Striker indicator - K (pic.) Power [W] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0 [g] Packaging

24 P Picture 1 Picture 7,5 1 R B C G 19 A E Dimensions [mm] Size A B C E G P R M O 1XL ,5 0,5 13, XL ,3 1, L , 17, NV 0V a.c. gg I/t characteristics

25 Safe work fuses Fuse links SWF ETI offer fuse links type SWF for protection against arc. Characteristics of SWF fuse links: - current limiting - short operating time - available in size 000,1,,3 acc. standard DIN 30 - marking like "SWF fuse link" - standard with top indicator By replacing NH fuse link with a characteristic gg acc. to VDE 03-1 with faster fuse link type SWF acc. to VDE 03-3, we can safeguard persons against electrical arc. Because of higher power, we can use SWF fuse link only between maintaince under voltage. After that, we must replace it with a gg fuse link. Damaged SWF fuse links must necessarily be replaced with new SWF fuse links. Arc energy E T I RMS x t E T (protection with SWF fuse link) 1 30 E T (protection with gg fuse link) Selection nominal current of SWF fuse link: (SWF) = (gg) SWF fuse links Size I Type Code Nr. Packaging [g] 3 M00C/SWF/3A/500V M00C/SWF/35A/500V M00C/SWF/0A/500V M00C/SWF/50A/500V C 3 M00C/SWF/3A/500V M00C/SWF/80A/500V M00C/SWF/0A/500V M00C/SWF/15A/500V M00C/SWF/A/500V M1/SWF/3A/500V M1/SWF/80A/500V M1/SWF/0A/500V M1/SWF/15A/500V M1/SWF/A/500V M1/SWF/00A/500V M1/SWF/A/500V M1/SWF/50A/500V M/SWF/15A/500V M/SWF/A/500V M/SWF/00A/500V M/SWF/A/500V M/SWF/50A/500V M/SWF/315A/500V M/SWF/350A/500V M/SWF/00A/500V M3/SWF/50A/500V M3/SWF/315A/500V M3/SWF/350A/500V M3/SWF/00A/500V M3/SWF/5A/500V M3/SWF/500A/500V

26 NH Power capacitor fuse fuse link 90V a.c. System voltage 00V a.c. Breaking capacity 0/kA Standards IEC 09 Description Special designed fuse according to rated power of 3 phase capacitor at nominal voltage 00V a.c. 50Hz. Current protection in low voltage reactive power compensation systems with 3 phase capacitor steps. Size Rated Power [kvar] At 00V Standard indicator Power ,8 1, ,8, , , , , , , , ,1 Packaging Pd(W) (g) (pcs) 15 3/ 173 3/90 Automatic Power Factor Correction Banks 8

27 Dimensions C 9,8 type dimensions [mm] A B C D E F G H K , Pre-arcing time (s) tv/s 3 1/1,5 kvar,5 kvar 3/ kvar 5 kvar kvar 1,5/15 kvar 0 kvar 5 kvar 30 kvar 0 kvar 50 kvar H E D G B A K F I-t characteristcs Capacitor rated power at 00V a.c. 50Hz Prospective current (A) Ip/A 9

28 Fuses for TVSS products protection SRF Series Surge Fuse Through the past few years, the transient voltage surge suppresion (TVSS) industry has grown to one of the fastestgrowing segments among power protection products. Newness from ETI is series of fuses named SRF (Surge Rated Fuses), intended for the protection of TVSS products. The SRF Series has been designed to survive 8/0 μs or /350 μs lighting surge pulses without operating, allowing the TVSS system to react to the surge. Surge fuses have either 8/0 μs or /350 μs ratings, not a continuous current rating. These fuses are intended to be installed in series with the TVSS devices and do not normally carry current, except for the periodic random surges caused by TVSS breakdown during normal operation. Under AC short circuit conditions these SRF surge suppression fuses have extremely high capability for current limitation. Features / Benefits 00V a.c. (8/0 μs) or 00V a.c. (/350 μs) Breaking capacity 00 ka (8/0 μs) or 50kA (/350 μs) Available in Surge Ratings from ka to 0 ka (8/0 μs) and 5 ka (/350 μs) Designed to meet UL19 Second Edition requirements, Comply with the applicable requirements in UL 8-1 Low Voltage Fuses Part 1, General Requirements. Approvals Recognized under the components program of Underwriters Laboratories for, File number UL E377 (SRF ). CH SRF class II Designed for Breaking capacity Standards 8/0 lighting surge pulses 00V a.c. 00kA a.c. Comply with the applicable requirements in UL 8-1 Low Voltage Fuses- Part1, General Requirements. These fuses are intended for installation in series with TVSS devices and do not normally carry current, except for the periodic random surges caused by TVSS breakdown during normal operation. CH SRF 8/0 μs Size Type Code No. 8x0 μsec Surge rating 1x51 Melting I t [A s] Total I t [A s] I PEAK at 130 ka CH1 SRF-II CH1 SRF0-II CH1 SRF30-II Packaging [g] /500 18, CH1 SRF0-II x58 CH SRF0-II /

29 CH SRF 5kA class I Designed for /350 lighting surge pulses 00V a.c. Breaking capacity 50kA a.c. Standard These fuses are intended for installation in series with TVSS devices and do not normally carry current, except for the periodic random surges caused by TVSS breakdown during normal operation. CH x58 SRF 5kA /350 μs Size Type Code Number /350 μsec Surge rating Pre-arcing Joule integral [A s] Operating Joule integral [A s] Packaging x58 CH SRF5 -I /0 55 [g] CH SRF class II - DC Designed for 8/0μsec lighting surge pulses 00V d.c. Breaking capacity 00A d.c. Fuses withstand not only a single shot of surge current, but a sequence of min.15 shots of surge current. Use in typical DC applilcation: PV Photovoltaic, battery supply, rectifier These fuses are intended for installation in series with TVSS devices and do not normally carry current, except for the periodic random surges caused by TVSS breakdown during normal operation. CH x58srf DC 8/0 μs Size x58 Type Code Number 8/0 μsec Surge rating Pre-arcing Joule integral [A s] Operating Joule integral [A s] CH SRF3-II-DC CH SRF8-II-DC CH SRF1-II-DC Packaging [g] /

30 Fuses for railway applications Advantages ETI s Railway Fuses successfully combine two usually conflicting fuse requirements: aa low operating joule integral, necessary for the protection of semiconductors, aa alow power, allowing for lower energy losses and thus lower operating costs, following the latest ecological trends. These unique technical characteristics are achieved by a completely new design of the ceramic body, a special construction developed on the basis of long standing expert knowledge, which allows for significantly better cooling of the fuse. The operation of fuses is especially adapted for railway applications, as they have improved resistance to current cyclic loading, a phenomenon that causes unnecessary fuse operating in these applications. This way, ETI s Railway Fuses help decrease downtime significantly, leading to further cost savings and improved efficiency. The melting element inside Railway Fuses is made of silver, which makes them highly insensitive to ageing processes. ETI Railway fuse-links ensure short circuit protection from minimum breaking capacity (5 x In) up to maximum breaking capacity 30kA d.c. at time constant 15ms. Protection of DC link and semiconductor devices (diodes, thyristors, GTO) in railway inverters. Standards ETI Railway Fuses comply with the IEC 09- and IEC standards. Fuse-link for auxiliary inverter Fuse-link for main inverter 3

31 NH1S/39/DC 000V ar-fuse link 000V d.c. (L/R=15ms), rated test voltage 00V d.c. Breaking capacity 30kA d.c. Characteristic ar Standards IEC 09-, IEC Heating system in railway vagon RAILWAY fuse link Code No. Type with centre Code No. Type without Power Pre-arcing Joule integral Operating Joule integral trip indicator for centre trip [W] [A s] [A s] microswitch MK indicator for (L/R=15ms) microswitch MK Note: microswitch MK and adapter AMK1 must be ordered separately Pack. [g] /1 33

32 3

33 NH S/39/ DC 000V ar - fuse link 000V d.c. (L/R=15ms), rated test voltage 00V d.c. Breaking capacity 30kA d.c. Characteristic ar Standards IEC 09-, IEC Fuse link for DC link protection of railway inverter. RAILWAY fuse link Code No. Type with centre Code No. Type without Power Pre-arcing Joule integral Operating Joule integral trip indicator for centre trip [W] [A s] [A s] microswitch MK indicator for (L/R=15ms) microswitch MK Note: microswitch MK and adapter AMK must be ordered separately Pack. [g] /1 35

34 3

35 NH1/350/DC 000V ar-fuse link 000V d.c. (L/R=15ms) Breaking capacity 30kA d.c. Characteristics ar Standard IEC 09-, IEC Heating system in railway vagon RAILWAY fuse link Code No. Power Pre-arcing Joule integral Operating Joule integral [W] [A s] [A s] (L/R=15ms) Pack. [g] /1 37

36 38

37 NH1/130/DC 00V gr - fuse link 00V d.c. (L/R=ms) Breaking capacity 30kA d.c. Characteristic gr Standards IEC 09- Railway inverter protection RAILWAY fuse link Code No. Code No. Type with centre trip indicator for microswitch MK+AMK Power (0,7 x ) [W] Power [W] Pre-arcing Joule integral Operating Joule integral [A s] [A s] (L/R=15ms) ,3 3, ,5, , Pack. [g] 900 1/ M

38 0

39 Fuses for high-voltage switchgear Fuses for high-voltage switchgear DB, S 38 Series For the protection of hight-voltage switchgear ETI offers a complete range of high-voltage fuses. The seriesconnected fuses provide failsafe surge protection for the downstream equipment in every situation. This is true for short circuits and also for overcurrents exceeding five times the value of the nominal current (5x ) Ø 0 DB, S 38 series fuses are main fuses designed for nominal currents of 7,5 A to 15 A. DB, S 38 series fuses are available for the following voltage ratings: 1 kv AC and 1 kv DC 1,5 kv AC and 1,5 kv DC 3 kv AC and 3 kv DC 5 kv DC This range of fuses covers all existing train line voltages of the European railway systems. Features Compact design different sizes Fuses designed for 5 kv DC Standards: UIC 550, EN 5013 and IEC s Main fuses for power supplies of rail vehicles, e.g. electric equipment and heating system Distribution fuses for branch circuits 1

40 Size U n [V] DB 1 00 Code No. 7, Packaging [g] 70 U n Code No. Packaging Size [V] [g] DB Size DB 3 U n [V] Code No , Packaging [g] 90 U n Code No. Packaging Size [V] [g] DB Size DB 5 U n [V] Code No Packaging [g] 99 Size U n [V] Code No. Packaging [g] DB

41 U n Code No. Packaging Size [V] [g] DB Size U n [V] S Code No Packaging [g] Size 1,, 3 and 5: Main fuses DB 1//3/5 Size 8: Main fuses S 38 B +0.3 B +0.3 A Ø3 Size, and 7: Main fuses DB //7 0 0 A Ø A 00 size dimensions [mm] A B DB 1 1 1,0 DB 1 1,0 DB 3 170,0 DB 170 7,5 DB 5 0,0 DB 300 7,5 DB ,5 S 38 38,0 B ( Ø ) 3

42 Dimensions according to IEC 09-, see also ETI general catalogue Max. Mejni value of prepustni current tok IO 5 3 Karakteristika mejnega prepustnega toka Cut-off characteristics SWF fuse links-size 00C,1,,3 SWF talilnega vložka-velikosti 00C, 1,,3 I I K 500A 00/5A 350A 315A 50A 00/A A 15A 0A 80A 3A 50A 35A 3A 0A I N /A Pre-arcing time Talilni čas t v [s] Time/current characteristics of fuse link type SWF-size 00C Time/current characteristics of fuse link type SWF-size 1,,3 Izklopne I/t karakteristike SWF talilnega vložka-velikosti 00C Izklopne I/t karakteristike SWF talilnega vložka-velikosti 1,, A 35A 0A 50A 3A 80A 0A 15A A 1 3 Prospective Pričakovani fault tok current kratkega stika I P Prospective Pričakovani fault tok current kratkega stika I P Pre-arcing time Talilni čas t v [s] A 80A 0A 15A A 00A 50A350A 5A A 315A00A500A 3 Prospective Pričakovani fault tok current kratkega stika I P

43 DB series 1.0 kv DB series 1.5 kv Time-current characteristics 1,0 kv Time-current characteristics 1,5 kv Pre-arcing time [s] t v /s 3 0 A 15 A A 7,5 A 30 A 5 A 70 A 0 A 50 A 0 A 35 A 0 A 15 A Pre-arcing time [s] t v /s 3 50 A 0 A 0 A 7,5 A 0 A A A Prospective current I p /A DB series 3.0 kv Pre-arcing time [s] t v /s 3 Time-current characteristics 3 kv - 3 Prospective current I p /A S 38 series 5 kv Pre-arcing time [s] t v /s 3 Time-current characteristics 5 kv 0 A 0 A 0 A 30 A 50 A 70 A 0 A 50 A 70 A 0 A 0 A A 0 A 15 A 30 A 0 A Prospective current I p /A - 3 Prospective current I p /A 5

44 Battery Protection Fuses in battery storage systems in UPS systems Short circuit current Short circuit current depending on battery model, type and capacity, low compared to operating current Short circuit current has to be interrupted in <5 seconds Required steep characteristics: protection with Battery fuse link required! Operating current Operating current depends on battery storage specification Battery operation: voltage of DC link circuit decreases to the final discharge votage Consider maximum current at final discharge voltage for fuse link selection Time/s te 0 operation 1 0,1 short-circuit 0,01 0,1 IB IK Current I/In 0 Short circuit point (I K ) Short circuit current depending on battery model and type Manufacturer datasheets to include short circuit current according to IEC89 Operating point has to be in adequate distance below the curve Short-circuit point has to be above the range of tolerance of the curve Operating point (t E /I B ) maximum operating curent I B has to be calculated from battery storage true power and final discharge voltage U E : I B = P W /U E t E is the back-up time of battery storage system When choosing fuse switch disconnector consider fuse link power! P d (I B ) < P y Power of fuse link at maximal operating current (I B ): P d (I B )=(I B / ) x P d ( ) I B - maximal operating current P d (I B ) - power of fuse link at maximal operating current P d ( ) - power of fuse link at nominal current P y - maximal permissible fuse link power mounted in fuse switch disconnector

45 CH x38 BATTERY Fuse link 550V d.c. 550V d.c. (L/R=ms) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection CH BATTERY fuse link Size Code No. Code No. Pre-arcing Operating Power Power Pack. standard contacts 550V DC type SU contacts 550V DC Joule integral L/R=ms Joule integral L/R=ms [0,7 x ] P d [1x ] P d 30kA 30kA [A s] [A s] [W] [W] [g] ,1 1,8 0,7 1,1 x ,0 7,8 0,5 1, ,1 7,3 0,73 1, ,1 53, 0,8 1, ,0 18,8 0,97, ,5 1,5 0,8 1, ,1, ,3 3, ,5,1 /1 /500 SU: /380 Note: CH Battery fuse links are used in combination with fuse disconnector EFH DC I/t characteristics for CH x38 Battery fuses 7

46 CH x38 BATTERY Fuse link 800V d.c. 800V d.c. (L/R=ms) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection CH BATTERY fuse link Size Code No. Code No. Pre-arcing Operating Power Power Pack. standard contacts 800V DC type SU contacts 800V DC Joule integral L/R=ms Joule integral L/R=ms [0,7 x ] P d [1x ] P d 30kA 30kA [A s] [A s] [W] [W] [g] , 1, 0,7 1,1 x , 8,9 0,5 1, ,5 7, 0,73 1, ,3 5,8 0,8 1, ,, 0,97, , 5, 0,8 1, , 9,3 1,1, /1 /500 SU: /380 Note: CH Battery fuse links are used in combination with fuse disconnector EFH DC Dimensions CH x38 Battery fuses 8

47 CH 1x51 BATTERY Fuse link 800V d.c. 800V d.c. (L/R=ms) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection CH BATTERY fuse link Size Code No. Code No. Pre-arcing Operating Power Power Pack. standard contacts 800V DC type SU contacts 800V DC Joule integral L/R=ms Joule integral L/R=ms [0,7 x ] P d [1x ] P d 30kA 30kA [A s] [A s] [W] [W] [g] , 3,1 1x ,5 3, ,1 5, ,3 5, 19/1 /00 SU: /0 Note: CH Battery fuse links are used in combination with fuse disconnector EFH 1 DC. Dimensions CH 1x51 Battery fuses 9

48 I/t characteristics for CH 1x51 Battery fuses NH BATTERY fuse link 80V d.c. Low power and fast characteristic in time range of 5s! 5A 0A 3A 0A A 0A 3A 50A 80A 15A 5s Pre-arcing time (s) tv/s Ik 5s -1-3 Prospective current (A) Ip/A Time-current characteristics NH00C and NH00 Discharge Charge Storage Max. Discharge Current 77 o F(5 o C) -0~0 o C -~0 o C -0~0 o C 00A(5s) Short Circuit Current 3300A Charge Methods: Constant Voltage Charge 77 o F(5 o C) Cycle use V Maximum charging current 0A Temperature compensation -30mV/ o C 50

49 Better protection of battery cells on overheating in case of short circuit comparable to standard gg characteristic te Pre-arcing time (s) tv/s 3 Time-current characteristics gg fuse 15 s + 1 5s 0-1 IB Battery fuse 80V d.c./a gg A/00Va.c. 3 Prospective current (A) Ip/A Ik Battery fuse 0, s + 80V d.c., L/R=ms Breaking capacity 50kA d.c.. Standard IEC 09 Battery protection 51

50 Pre-arcing time (s) tv/s 3 NH BATTERY fuse link 80V d.c. Size Standard indicator 00C 00 1C 1 Power Pack. Pic. 1 [W] [g] , , , 15 3/ , , , , , / , , , , , , ,8 33 3/ , , , , / I/t characteristics for NH Battery fuses 80V d.c. 5A 0A 3A 0A A 0A 3A 50A 80A 15A Pre-arcing time (s) tv/s 3 5A 0A 3A 0A 3A 50A 80A 0A A 50A 15A 00A Prospective current (A) Ip/A Time-current characteristics NH00C and NH Prospective current (A) Ip/A Time-current characteristics NH1C and NH1 5

51 Dimensions NH Battery fuses 80 V d.c. pic. 1 C 9,8 H E D G B A K F Size A B C D E F G H K , C Fuses for protection of forklift batteries TRB 80V d.c. Standards DIN 350/1 TRB fuse-links are used to protect the forklift battery TRB fuse link Type Code Nr. 35 TRB 35A/80V TRB 50A/80V TRB 3A/80V TRB 80A/80V TRB 0A/80V TRB 15A/80V 0035 TRB A/80V TRB 00A/80V TRB 50A/80V TRB 300A/80V TRB 355A/80V TRB 5A/80V [g] Packaging 0 53

52 Dimensions TRB fuses NH BATTERY fuse link 0V d.c. 0V d.c., L/R=ms (NH1C), L/R=5ms (NH00) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection NH BATTERY fuse link Size Standard indicator 00 1C Power Pack. [W] [g] , , , , / , , , , , , ,8 33 3/ , , , 5

53 Dimensions C 9,8 Pre-arcing time (s) tv/s E D G B A H K F type dimensions [mm] A B C D E F G H K C I/t characteristics 5A 0A 3A 0A A 0A 3A 3A 50A 0A 80A 0A 3A 50A 80A 15A 3 Pre-arcing time (s) tv/s Time-current characteristics NH1C 3 Prospective current (A) Ip/A Prospective current (A) Ip/A Time-current characteristics NH00 55

54 NH BATTERY fuse link 550V d.c. 550V d.c. (L/R=ms) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection NH BATTERY fuse link Size Standard indicator 1 3 Striker indicator Standard indicator S1mm Power Pack. pic. 1 pic. 1 pic. [W] [g] / / /

55 NH BATTERY fuse link 700V d.c. 700V d.c. (L/R=ms) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection NH BATTERY fuse link Size Standard indicator 1 3 Striker indicator Standard indicator S1mm Power Pack. pic. 1 pic. 1 pic. [W] [g] / / /

56 NH BATTERY fuse link 800V d.c. 800V d.c. (L/R=ms) Breaking capacity 30kA d.c. Standard IEC 09 Battery protection NH BATTERY fuse link Size Standard indicator 1 Striker indicator Standard indicator S1mm Power Pack. pic. 1 pic. 1 pic. [W] [g] / / Dimensions NH Battery fuses pic. 1 Size A B C E G S L N P R T ,5 13,7 7, ,3 1, 7, , 17 7,5 58

57 pic. 11 G B 11 A C E D Size A B C D E G I/t characteristics for NH Battery fuses t v /s 3 35A 0A 50A 3A 80A 0A 15A A00A A 50A 00A 350A 315A 5A 500A 30A I /A p 59

58 Fuel Cell Fuses The characteristics of fuel cell fuses FCF are developed according to standard ISO to meet the needs of fuel cell protection. Fuse links are used in fuel cell applications up to the nominal voltage 50V d.c. and maximum breaking capacity 000A at time constant up to ms. Minimum breaking capacity is x at nominal voltage. Without the protection of the specially designed FCF, the high DC voltage could experience severe arcing, thermal incidents or other hazards in the event of the overload or short circuit on fuel cells. v The decign of FCF is based on DC fuses. It has been redesigned to fit the needs the fuel cell protection acc. to Standard ISO Fuel cell fuse-fcf is a reverse current protection device for a fuel cell of a power circuit and it protects the fuel cell from damage caused by reverse current into the fuel cell. : 50V d.c. (L/R=ms) Breaking capacity: ka d.c. Standard: ISO : For protection of fuel cells F C FUSE CH x38 FUEL CELL FUSE DC Size Code No. type SU contacts 50V d.c. t /s x38 Pre-arcing Joule integral [A s] L/R=ms Operating Joule integral [A s] L/R=ms Power [0,7 x ] P d [W] Power [1x ] P d [W] ,3 0, , 0, , 1, , 1, , 1, ,8 1, ,0, A A 8A A 1A 1A 0A [g] Packaging 1 / ,0-0,8 9,-51,0-0 1 I p/a 3 0

59 1 June 015 ETI d.d. withholds the right to make changes and additions to any information contained herein.

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Multimeter fuses Metering Fuses Telecom fuses NH 80V Fuses for DC voltage applications NH am 00V a.c. NH gg 0V a.c. Safe work fuses SWF Fuses for protection of forklift batteries

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL GREEN PROTECT DC - distribution and protection components Cylindrical fuse-links Fuse holders for cylindrical fuse-links Accessories for cylindrical fuses NH fuse -links NH fuse bases NH fuse disconnectors

More information

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:

More information

Low voltage NH knife-blade fuse-links

Low voltage NH knife-blade fuse-links Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS

More information

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4 URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Ultra Rapid Fuses. For Semiconductor Protection

Ultra Rapid Fuses. For Semiconductor Protection UR Ultra Rapid Fuses For Semiconductor Protection Over many decades SIBA has developed a very comprehensive product line of Ultra Rapid fuses that has achieved worldwide acceptance. SIBA's worldwide distribution

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25

More information

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A DISTRIBUTION SOLUTIONS Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A Continuous protection and reliable operation Proven design and compliance with newest fuses standards Compatibility with other ABB

More information

Limitor -G General Purpose Fuses

Limitor -G General Purpose Fuses Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 200A 1. General information P&C Medium Voltage fuse-links named PCEF are designed

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

Protistor size 70 gr 690VAC (IEC)

Protistor size 70 gr 690VAC (IEC) Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017 HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH

More information

1500V. Now Available

1500V. Now Available 1500V Now Available Since 198, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

High voltage high-breaking capacity VV fuse-links

High voltage high-breaking capacity VV fuse-links High fuse-links High fuse-links High high-breaking capacity VV fuse-links VV General information ET fuse-links named VV THERMO are designed to protect devices in switch-gears and other equipment (distribution

More information

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design

More information

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction. HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main

More information

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

Mini DC - Isolators for Photovoltaic

Mini DC - Isolators for Photovoltaic Mini DC - Isolators for Photovoltaic acc. to IEC 60364-7-712 Quality made in D1024E171 Technical catalogues and news under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL GREEN PROTECT DC distribution and protection components Cylindrical fuselinks Fuse holders for cylindrical fuselinks Accessories for cylindrical fuses NH fuse links NH fuse bases NH fuse disconnectors

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Utilisation category gl/gg 500VAC with combi indicator

Utilisation category gl/gg 500VAC with combi indicator DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 0A 1. General information P&C Medium Voltage fuse-links named PCEF are designed to

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Medium voltage products. Fuses

Medium voltage products. Fuses Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

High Reliable Components for Power Factor Correction and Power Quality

High Reliable Components for Power Factor Correction and Power Quality High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Contents Power Factor Correction Capacitors Page 3 Basic Harmonic Filter Reactors Page 11 Standard

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Thermal Overload Relays - WEG RW Series, 2 Pole

Thermal Overload Relays - WEG RW Series, 2 Pole International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20. Connect - Contact - Control Contactors CT5/0, CT0/0 CT5/0, CT0/0 CT5/0, CT0/0, and pole power contactors for AC and DC Catalogue C0.en Power contactors for AC and DC, Series CT Owing to a new blowout technology,

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links imum cold resistance power dissipation pre-arcing I t value total I t value [kv] (mm) I n [A] (ka) [mω] [W] [A s] [A s] 1 580,1 57 A 0 370 9 17,3 1 A 5 00 10 3 30 10 A 55 7 11

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Short-circuit current limiter S800-SCL-SR

Short-circuit current limiter S800-SCL-SR Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Control switch/load disconnect switch Series 8008

Control switch/load disconnect switch Series 8008 > s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

Medium voltage products. Fuses

Medium voltage products. Fuses Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Low Voltage Fuses. Safety in Focus. ZVEI.ppt / / 1

Low Voltage Fuses. Safety in Focus. ZVEI.ppt / / 1 Low Voltage Fuses Safety in Focus ZVE.ppt / 05.01 / 1 Applications, Product Advantages Fuses protect Human life Electrical circuits Electrical products Electronics Cables and conductors Product advantages

More information

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

High voltage current limiting Fuse links type CEF

High voltage current limiting Fuse links type CEF High voltage current limiting Fuse links type CEF Index 1. General........................................... 9 2. Overvoltages...................................... 9 3. Pre-arcing times and cut-off characteristics..............

More information

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS 1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Filters and Fans Fuse Switch Disconnectors XNH Thermostats Terminals Catalogue 2017 Electrical Cabinet Heating Fuse

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system Premium PFC Capacitors General capacitors in cylindrical aluminum cases have been designed for power factor correction in low-voltage plant. Loads like motors and transformers consume active power as well

More information

High Reliable Components for Power Factor Correction and Power Quality

High Reliable Components for Power Factor Correction and Power Quality High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Power Factor Correction Capacitors Type LKT Features that matter: Overcurrent up to 2.2 times rated

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information