Weatherproof Products
|
|
- Amos Garrison
- 5 years ago
- Views:
Transcription
1 Technical Specifications pplications : Junction for branch conduits in hazardous locations ccessible wiring chamber provides a convenient location to maintain or change a system, pull conductors and make splices Internal hub design ideal for installation where space is limited Features/enefits : opper-free (less than copper content) aluminum provides increased corrosion resistance Precision cast and machined surfaces permit safer wire pulling Precision NPT threaded hubs allow trouble-free field installation for rigid or IM conduit Die cast construction and industrial design combine to produce a rugged protective enclosure for devices on industrial and OEM applications lear UL, S and cubic content markings speed approval by inspectors Standard Materials : Die cast aluminum alloy 360 (less than copper content) Standard Finish : luminum lacquer finish ompliances : ompliances as noted on each page of the catalogue include: S ertified UL Listed Suitable for hazardous locations lass I, Groups, D NEM 7D lass II, Groups E, F, G 9EFG lass III, Divisions 1 and 2 12 opper-free aluminum (less than copper content) Internal hub design Smooth conduit stops Precision machined threads Internal ground boss and screw 36
2 Internal Hubs with installed Green Ground Screw EXUN-1 Hub Size Description 5 Hole Outlet oxes (ast luminum) EXUN-1 1/2 5 outlets with 3 close-up plugs 3-31/ / EXUN-2 3/4 5 outlets with 3 close-up plugs 3-31/ / EXUN outlets with 3 close-up plugs 3-31/ / Hole Outlet oxes (ast luminum) EXUN-11 1/2 4 outlets with 2 close-up plugs 3-31/ / EXUN-22 3/4 4 outlets with 2 close-up plugs 3-31/ / E F u. 37
3 Technical Specifications pplications : Junction for branch conduits in hazardous locations ccessible wiring chamber provides a convenient location to maintain or change a system, pull conductors and make splices Unique mounting pads and external hub design ideal for installations of OEM devices or instruments Features/enefits : opper-free (less than copper content) aluminum provides increased corrosion resistance Precision cast and machined surfaces permit safer wire pulling Precision NPT threaded hubs allow trouble-free field installation for rigid or IM conduit Die cast construction and industrial design combine to produce a rugged protective enclosure for devices on industrial and OEM applications lear UL, S and cubic content markings speed approval by inspectors Standard Materials : Die cast aluminum alloy 360 (less than copper content) Standard Finish : luminum lacquer finish ompliances : ompliances as noted on each page of the catalogue include: S ertified UL Listed lass I, Div. 1 and 2, Groups, D Explosion proof lass II,Div. 1, Groups E, F, G Dust-Ignition proof lass III, Div. 1 and 2 Raintight NEM 3, 4, 7 D, 9 EFG Wet Locations opper-free aluminum (less than copper content) Unique mounting pads External hub design Internal ground boss and screw Smooth conduit stops Precision machined threads 38
4 Internal Hubs with installed Green Ground Screw G GL GT Hub Size over Opening Through Feed with Surface (ast luminum) G-1 1/2 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ G-2 3/4 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ L Style with Surface over (ast luminum) GL-1 1/2 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GL-2 3/4 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GL / /4 2-15/16 1-3/8 2-7/32 5-1/2 5-9/ GL-4 1-1/4 3-29/32 4-5/ /16 2-1/16 7/8 5-11/ GL-6* 2 5-3/16 5-3/4 4-1/4 5-1/16 2-7/8 7/8 6-5/ T Style with Surface over (ast luminum) GT-1 1/2 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GT-2 3/4 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GT / /4 2-15/16 1-3/8 2-7/32 5-1/2 5-9/ GT-4 1-1/4 3-29/32 4-5/ /16 2-1/16 7/8 5-11/ L Style with Surface over (ast luminum) GL-1 1/2 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GL-2 3/4 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GL-3* / /4 2-15/16 1-3/8 2-7/32 5-1/2 5-9/ X Style with Surface over (ast luminum) GX-1 1/2 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GX-2 3/4 3-11/ /4 2-15/16 1-3/8 1-1/16 5-3/16 5-9/ GX-3* / /4 2-15/16 1-3/8 2-7/32 5-1/2 5-9/ D Suffix-OR: O-ring available for NEM 4 rating * Made to order items. onsult your Regional Sales Office for lead time and minimum quantities F G H u. GL GX 39
5 Internal Hubs with Green Ground Screw, overs and Plugs Hub Size over Opening X Style with Flange and Surface over (ast luminum) GFX-1 1/2 3-11/ /4 2-15/16 5-9/16 4-1/2 1/4 1-3/8 3-5/ GFX-2 3/4 3-11/ /4 2-15/16 5-9/16 4-1/2 1/4 1-3/8 3-5/ GFX-3-OR* / /4 2-15/16 5-9/16 4-3/4 5/16 1-3/8 5-1/ D F G H M u. GFX Hub Size U Style with anopy over (ast luminum) GJU-2* 3/ / /16 1-1/2 31/32 5-3/16 GJU / /16 1-1/2 31/32 5-3/16 GJU /4 6-7/16 6-5/8 1-7/16 2-1/16 1-1/2 6-5/8 D * Made to order items. onsult your Regional Sales Office for lead time and minimum quantities. E F G GJU 40
6 Internal Hubs with installed Green Ground Screw over Opening Fits oxes Dome Style over Inside Height 2-5/8 in. (lass I, Group D only) (ast luminum) GD GD-123* 3-11/16 1/2, 3/4, 1 anopy Style over (ast luminum) GJ-123* 3-11/16 1/2, 3/4, 1 GJ-4* 3-29/32 1-1/4 GJ-56* 5-3/16 1-1/2, 2 Surface Style over (ast luminum) GS-123* 3-11/16 1/2, 3/4, 1 GS-4* 3-29/32 1-1/4 GS-56* 5-3/16 1-1/2, 2 * Made to order items. onsult your Regional Sales Office for lead time and minimum quantities GJ GS Hub Size lose-up Plugs for (ast luminum) XPLG-1 1/2 XPLG-2 3/4 XPLG-3 1 XPLG-4 1-1/4 XPLG-5 1-1/2 XPLG-6 2 XPLG-1 XPLG-4 41
7 Technical Specifications pplications : Junction for branch conduits in hazardous locations ccessible wiring chamber provides a convenient location to maintain or change a system, pull conductors and make splices. Features/enefits : opper-free (less than copper content) aluminum alloy provides increased corrosion resistance Extra wide 3-3/4 in. opening provides more hand space for easy access to the wiring chamber Precision cast and machined surfaces permit safer wire pulling Large capacity 31 cu. in. chamber provides more wiring space Precision NPT threaded hubs allow trouble-free field installation for rigid or IM conduit Sand cast construction and industrial design combine to produce a rugged protective enclosure for devices on industrial and OEM applications lear UL, S and cubic content markings speed approval by inspectors Hub spacing allows use of EXFU and EXMU unions Standard Materials : ox: Sand ast aluminum alloy T6 over: Die ast aluminum alloy 360 (less than copper content) Standard Finish : luminum lacquer finish ompliances : ompliances as noted on each page of the catalogue include : ertifiées S S ertified UL Listed NE Suitable for hazardous locations lass I, Groups, D NEM 7D lass II, Groups E, F, G 9EFG lass III, Divisions 1 and 2 12 lean cover edges Heavy wall construction Internal ground boss and screw Precision machined threads opper-free aluminum (less than copper content) 42
8 Internal Hubs with Green Ground Screw, overs and Plugs Hub Size over Opening Outlet oxes with Surface over (ast luminum) D E G H GSS-1 1/ /8 2-3/8 3-3/8 2-3/16 1-3/16 3/ GSS-2 3/ /8 2-3/8 3-3/8 2-3/16 1-3/16 3/ GSS /8 2-3/8 3-3/8 2-3/16 1-3/16 3/ u. GSS Dimensions of all styles when GSS cover is used 43
Rigid/Aluminum Conduit Bodies, Gaskets and Covers
Rigid/luminum Conduit odies, Gaskets and Covers Conduit odies, Covers and Gaskets Weatherproof oxes and Covers pplications Junction for branch conduits Series bodies for Rigid and IMC conduit maintain
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationForm 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.
For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationForm 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationFM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More informationFM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More informationFM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationJunction Boxes Hazardous and Non-Hazardous
Junction Boxes Hazardous and Non-Hazardous Description Page No. Application/Selection 112 Boxes Flush EGJ Series 19 WJBF Recessed Sidewalk Cover Series 116 Service Station EGJ Series 19 GUA Series 17 GUP
More informationLB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationSpec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch
More informationEXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable
More informationGround Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB
lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2
More informationALUMINUM OUTLET BODIES
KILLARK GEB SERIES ALUMINUM OUTLET BODIES * Class I, one I, Groups IIC, IIB, IIA Type 4X Applications GEB series conduit boxes are installed in conduit systems within hazardous areas to: Protect conductors
More informationProduct Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33
SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9
More information24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A
24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion
More informationJ-1. Explosion-Proof Junction Unilets. Features: Junction Boxes Outlet Boxes
Explosion-Proof Junction Unilets J-1 Features: Junction Boxes Outlet Boxes Compliance Data:, Groups B, C, D; Class I Zone 1 and 2, IIB + H 2 T6, Class III, Enclosure 3, weatherproof EEMAC Type 3R, 7BCD,
More informationAluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades. Allows connection of straight conduit runs, branch
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More informationW94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection
Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2
More informationConduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.
-2 Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; UNILETS for use with Threaded Metal Conduit. Applications Meet a wide range of classified area requirements. Corrosion-resistant ideal indoors
More informationAKRON ELECTRIC, INC. CONDUIT PRODUCTS GR SERIES... EYS SERIES... TU SERIES... XBD-50 SERIES...
CONDUIT PRODUCTS F GR SERIES... EYS SERIES... TU SERIES... XBD-50 SERIES... 1025 Eagon St. Barberton, Ohio 44203 Ph:(330) 745-8891 Fax:(330) 745-2504 Toll Free:(800)-275-2535 06/09/03 NEW PRODUCT IN STOCK
More informationPEERLESS BLOWERS DIRECT DRIVE BLOWERS
PEERLESS BLOWERS DIRECT DRIVE BLOWERS PEERLESS BLOWERS DIRECT DRIVE BLOWERS APPLICATION: Used extensively for general ventilation of small areas where duct systems are required. Used for washrooms, restaurants
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationNon-Metallic Weatherproof Boxes, Covers and Lampholders
Non-Metallic Weatherproof oxes, s and Lampholders pplications Marine rated boxes and covers are ideal for use in highly corrosive areas, beaches, docks, pools, or other wet location areas. Use in branch
More informationSwitches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures
S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments
More informationENR Value Series Dead Front Interlocked Circuit Breaking Receptacles
ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationT38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationSurface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L
Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L Part #: EPL-48-2L-T12VHO Made in the USA The Larson Electronics EPL-48-2L-T12VHO Explosion Proof Fluorescent
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More informationCondulet Conduit Bodies and Outlet Boxes Hazardous
Condulet Conduit Bodies and Outlet Boxes Hazardous 4F Description Page No. Application/Selection 48, 49 Lubricants HTL 59 STL 59 Conduit Bodies & Outlet Boxes Cylindrical EKC 57 90 Elbow LBH 58 LBY 58
More informationJM - Junction Enclosure Modules for Communication Networks
Pub #110014revB, Part 1-12/2002 JM - Junction Enclosure Modules for Communication Networks Installation & Adjusting Instructions for JMT, JMP, JMS, JMD, JMB series The JM provides a watertight / explosion
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationArktite Plugs and Receptacles Industrial Heavy Duty Hazardous
Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection 1000, 1001 Arktite Delayed Action Circuit Breaking Technical Data 1002, 1003 20 & 30A CPS Receptacle
More informationEnclosures. Section E
Enclosures Section E Enclosures and junction boxes built and configured to meet the requirements of the most demanding hazardous areas and industrial environmental applications across the globe. E Enclosures
More informationGLASS INDUSTRIAL THERMOMETERS
TEL-TRU MANUFACTURING COMPANY GLASS INDUSTRIAL THERMOMETERS World -Class Thermometers Since 1916 www.teltru.com Glass Industrial Thermometers Tel-Tru Glass Industrial Thermometers are used on pipelines
More informationEDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.
EDS Factory Sealed Tumbler Switches UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D NEMA 7 B CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationApplications. Standard Materials
Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division
More informationCable & Wire Management
able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationTwist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly
Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Part #: EPO-25A The Larson Electronics EPO-25A explosion proof power outlet provides a durable and secure weatherproof power connection
More informationFM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationEDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.
UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect
More informationExplosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst
Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst Part #: EXP-EMG-EXT-12W-1LX Page: 1 Made in the USA The EXP-EMG-EXT-12W-1LX Explosion Proof Emergency
More informationCode Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.
Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationApplications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.
Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationCondulet Cast Device Boxes and Covers Application and Selection
F Condulet Cast and Covers Application and Selection Application: Cast device boxes are installed in conduit and cable systems to: Accommodate wiring devices Act as pull boxes for conductors in a conduit
More informationControl Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments
leverless limit switches Proximity Sensors for Harsh Environments and Tough Applications Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments Certified for use in all
More informationW-Series Junction Boxes
W-Series Junction Boxes Application and Selection Junction boxes, designed for hazardous and non-hazardous locations, are used in a variety of industries to perform the following functions: As a pull box
More informationEngineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)
4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices
More informationCEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2
Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers
More informationExplosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC
9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB
More informationCondulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit
Condulet Single Gang Cast Accessories Pages to 44 F Application: Cast device boxes are installed to: accommodate wiring devices act as pull boxes for conductors in a conduit system provide openings to
More informationEY, EYD, & ENY Series
EY, EYD, & ENY Series SELING For Harsh & Hazardous Environments Z H LO C EY SERIES SELING ENY ENY with Nipple (For Vertical or Horizontal Conduit) EY EY with Nipple (For Vertical Conduit) ENY-2 (Fixture
More informationApplications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings
Selection Guide Severe Duty Mill and Foundry Switches pplications Mill Mill Mill Mill Design 9007T Convertible sequence L0 Fixed sequence L14 Single Cable Pulls Fixed sequence L525 elt Conveyor Fixed sequence
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationPressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction
K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller
More informationMultiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous
Proximity Limit Switch The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous metals. All components are sealed and protected within the rugged brass housing eliminating
More informationArktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed
Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,
More informationThree Phase Transformers
Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series
More informationLiquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat
Liquid Tight Connectors Reusable Fittings Industrial specification grade, screw machined steel, zinc plated UL Rated Liquid Tight Includes sealing washer Bonds conduit to box or enclosure Corrosion resistant
More informationITT. CentriPro Fiberglass Basins, Covers, Hatches, Access Doors and Accessories. CentriPro. Engineered for life BCBASIN R4. Wastewater.
CASIN R4 ITT CentriPro Fiberglass asins, Covers, Hatches, Access oors and Accessories CentriPro is a brand of ITT Corporation. www.centripro.com CentriPro Features Fiberglass asins - heavy duty construction,
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2288626 Master Contract: 184585 Issued to: CMP Products Ltd Glasshouse St. St. Peters Newcastle Upon Tyne, NE6 1BS United Kingdom Attention: Dave Willcock The products
More informationUser s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition
User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement
More information8146 Series F16 CONTROLS CONTROL STATION IN POLYESTER RESIN. Features: Components:
8146 Series ONTROLS ONTROL STTION IN POLYESTER RESIN LSSIFITIONS NE- lass I, Zones 1 & 2 Ex e II T6 lass I, ivision 2, Groups,,, lass II, ivision 2, Groups F,G lass III NEM 3,4 & 4X; IP66 LISTE - FILE
More information1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB57SA 1-1/2 Al LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category
More informationMaterial, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T37 1 T FM7 CND BD Appleton/Oz Gedney Catalog Number T37 Manufacturer Appleton/Oz Gedney Description FM7 Unilets Type
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationLighting: Explosionproof Area HID. Applications. Standard Materials
Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division
More information8146 Series Terminal Boxes
8146 Series Terminal oxes TERMINTION Ready-Term 8146 Terminal oxes Features: Pre-onfigured with terminals mounted Made of Fiberglass Reinforced Polyester (FRP) 8 enclosure sizes with different depths For
More informationExplosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm
Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm Part #: EPL-DL-70LED-24 Page: 1 Made in the USA The EPL-DL-70LED-24 Explosion Proof Dock Light is U.L. approved
More informationHID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as
More informationElectronic Temperature Control & Bulb Well Assembly (AC)
Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed
More informationValve Position Monitors
Valve Position Monitors EX Series for Hazardous Locations APL Series NEMA 4, 4X 1 LIMIT SWITCHES Triac APL Series Limit Switches The Triac APL Series Limit Switches feature high quality, easy to use multiple
More informationTHE RIGHT SOLUTION FOR EVERY APPLICATION
VFD ABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLIATION Products Added VFD Lean TR VFD Dual TR Servo VFD ombo DS VFD XLPE TR VFD XLPE 2KV TR Also Included! FLEXIBLE ONTROL ONTINUOUS FLEX SILIONE
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control
DATUM Series 8 Noflote Conductivity Level System Reliable on/off liquid level control for alarms or pump control Suitable for most conductive liquids including water, sewage, dilute acids and beer Durable
More informationOptional Features and Accessories
Optional Features and ccessories Million Cycle Valves Vacuum Research Valves have been designed to eliminate sliding friction to extend operating life and reduce particle generation. For example, all of
More information4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors
.2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationHDE SERIES CONNECTOR TABLE OF CONTENTS
HDE SERIES COECTOR TLE OF COTETS Product pplications Code Logic 5 Code Logic Continued / Examples 6 HDE Features Product Options 8 Component ensions 9 Receptacle ensions 0 Grommets - Insert rrangements
More informationDiaphragm Switch BM65
Diaphragm Switch BM65 BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com 1 BM65 R, RH, RHT Explosion Proof Diaphragm BM65
More informationELECTRICAL INSTALLATION
ENCLOSURE DIMENSIONS NOTES (3) 3/4" NPT WALL MOUNT BRACKET, (2) 5/16" DIA. THRU - HARDWARE IS CUSTOMER SUPPLIED 1¼" NPT AUTO-TEST OPTION 6.312" 160.3 mm 4.85" 123 mm 3.90" 99 mm 4.95" 126 mm 4.85" 123
More informationArktite Plugs and Receptacles Industrial Heavy Duty Hazardous
Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection see pages 1260 1261 Arktite Delayed Action Circuit Breaking Technical Data see pages 1262 126 20
More informationForm 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationEFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect
More informationJunction Boxes & Enclosures JBES Series: Pre-drilled 316L Stainless Steel Junction Boxes Increased Safety
Je10 Without Terminals ompliance ata: TEX - IE: TEX IE E Ex e II; Ex ia II; Ex ib II T6 to T5 Ex t 21 T80 to T95 Operating Temperatures: -50 to +70 199 TX Product atalog pplications: Terminal junction
More informationContender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.
Contender Series Factory Sealed Control Stations and Pilot Lights Furnished with Internal Ground Screw. Applications Push buttons and selector switches are used in conjunction with contactors or magnetic
More informationACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationW Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications
W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications This table shows the optional items available on the different types of enclosures shown in this
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More information