LOW & MEDIUM PRESSURE FILTERS

Size: px
Start display at page:

Download "LOW & MEDIUM PRESSURE FILTERS"

Transcription

1 LOW & MEDIUM PRESSURE FILTERS

2

3 A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests of a market still to be fully explored, with the study, design, development, production and marketing of a vast range of fi lters for hydraulic equipment, capable of satisfying the needs of manufacturers in all sectors. The quality of our products, our extreme competitiveness compared with major international producers and our constant activities of research, design and development has made us a worldwide leader in the fi eld of hydraulic circuit fi ltering. Present for 50 years in the market, we have played a truly decisive role in defi ning our sector, and by now we are a group capable of controlling our entire chain of production, monitoring all manufacturing processes to guarantee superior quality standards and to provide concrete solutions for the rapidly evolving needs of customers and the market.

4 MARKET LEADER Our work is based on a skillful interaction between advanced technology and fine workmanship, customizing products according to specific market requests, focusing strongly on innovation and quality, and following every step in the manufacturing of both standard and special products, fully respecting customer expectations. Our customer-oriented philosophy, which enables us to satisfy all customer requests rapidly and with personalized products, makes us a dynamic and flexible enterprise. The possibility of constantly controlling and monitoring the entire production process is essential to allow us to guarantee the quality of our products. Introduction

5 WORLDWIDE PRESENCE Our foreign Branches enable us to offer a diversified range of products that allow us to successfully face the aggressive challenge of international competition, and also to maintain a stable presence at a local level. The Group boasts 8 business branches USA CANADA UNITED KINGDOM FRANCE GERMANY ITALY RUSSIA P.R. CHINA INDIA Introduction

6 TECHNOLOGY Our constant quest for excellence in quality and technological innovation allows us to offer only the best solutions and services for applications in many fields, including general industry, test rigs, lubrication, heavy engineering, renewable energies, naval engineering, offshore engineering, aviation systems, emerging technologies and mobile plant (i.e. tractors, excavators, concrete pumps, platforms). Introduction

7 AND PRODUCTION Our high level of technological expertise means we can rely entirely on our own resources, without resorting to external providers. This in turn enables us to satisfy a growing number of customer requests, also exploiting our constantly updated range of machines and equipment, featuring fully-automated workstations capable of -hour production. 5 Introduction

8 SUCTION FILTERS RETURN FILTERS RETURN / SUCTION FILTERS SPIN-ON FILTERS LOW & MEDIUM PRESSURE FILTERS HIGH PRESSURE FILTERS Flow rates up to 875 l/min Flow rates up to 000 l/min Flow rates up to 00 l/min Flow rates up to 65 l/min Flow rates up to 000 l/min Flow rates up to 750 l/min Mounting: - Tank immersed - In-Line - In tank with shut off valve - In tank with fl ooded suction Pressure up to 0 bar Mounting: - In-Line - Tank top - In single and duplex designs Pressure up to 80 bar Mounting: - In-Line - Tank top Pressure up to 5 bar Mounting: - In-Line - Tank top Pressure up to 80 bar Mounting: - In-Line - Parallel manifold version - In single and duplex designs Pressure from 0 bar up to 560 bar Mounting: - In-Line - Manifold - In single and duplex designs Introduction 6

9 PRODUCT RANGE MP Filtri can offer a vast and articulated range of products for the global market, suitable for all industrial sectors using hydraulic equipment. This includes filters (suction, in-line, pressure, stainless steel, spin-on and return) and structural components (motor/pump bell housings, transmission couplings, flexible inserts, damper rings, support feet, aluminium tanks, inspection hatches). We can provide all the skills and solutions required by the modern hydraulics industry to monitor contamination levels and other fl uid conditions. Mobile fi ltration units and a full range of accessories allow us to supply everything necessary for complete hydraulic circuits. STAINLESS STEEL HIGH PRESSURE FILTERS CONTAMINATION MONITORING PRODUCTS MOBILE FILTRATION UNITS POWER TRANSMISSION PRODUCTS ACCESSORIES Flow rates up to 5 l/min Pressure from 0 bar up to 000 bar Mounting: - In-Line - Manifold - In single and duplex designs - Calibrated on test rigs manufactured and certifi ed to ISO 9 based on methods from ISO 7 - Off-line and In-line particles counting up to 00 bar - Bottle samplers - RS - RS 85 digital bus interfaces Flow rates from 5 l/min up to 00 l/min - Aluminium bell-housings for motors from 0. kw to 00 kw - Couplings in Aluminium Cast Iron - Steel - Damping rings - Foot bracket - Aluminium tanks - Cleaning covers - Oil fi ller and air breather plugs - Optical and electrical level gauges - Pressure gauge valve selectors - Pipe fi xing brackets - Pressure gauges 7 Introduction

10 HYDRAULIC FILTRATION PRODUCTS page INTRODUCTION COMPANY PRODUCT RANGE CONTAMINATION MANAGEMENT FILTER SIZING CORRECTIVE FACTOR page STR - MPA - MPM SF SF 500 CLOGGING INDICATORS SUCTION FILTERS Submerged suction filter, with bypass or magnetic column Semi-submerged positive head suction filter Semi-submerged positive head suction filter up to Q max l/min gpm page MPFX MPTX MFBX MPF MPT MFB MPH - MPI FRI RF CLOGGING INDICATORS ACCESSORIES RETURN FILTERS Tank top semi-immersed filter, standard filter element disassembly Tank top semi-immersed filter, easy filter element disassembly Bowl assembly fully immersed filter Tank top semi-immersed filter, standard filter element disassembly Tank top semi-immersed filter, easy filter element disassembly Bowl assembly fully immersed filter Tank top semi-immersed filter with internal / external oil flow Tank top semi-immersed filter, easy filter element disassembly, it can be used also as in-line filter Semi-immersed under-head filter, easy filter element disassembly up to P max bar psi up to Q max l/min gpm page MRSX LMP MULTIPORT CLOGGING INDICATORS RETURN / SUCTION FILTERS Unique TANK TOP filter for mobile machinery, with combined filtration on return and suction to the inlet at the hydrostatic transmissions in closed circuit. Unique IN-LINE filter for mobile machinery, with combined filtration on return and suction to the inlet at the hydrostatic transmissions in closed circuit. up to P max bar psi up to Q max l/min gpm page MPS MSH MST CLOGGING INDICATORS SPIN-ON FILTERS Low pressure filter, available with single cartdridge for in-line or flange mounting or with two cartdridge on the same axis on the opposite sides In-line low and medium pressure filter available with single cartdridge Low pressure tank mounted filter up to P max bar psi up to Q max l/min gpm Introduction 8

11 INDEX 0 page LMP MULTIPORT LMP 0 - LMP LMP LMP LMP LMP LMD LMD LMD 95 LDP - LDD CLOGGING INDICATORS LOW & MEDIUM PRESSURE FILTERS In-line filter with Multiport design for multiple choice connection In-line low & medium pressure filter In-line low & medium pressure filter In-line low pressure filter, filter elements designed according to DIN 550 In-line filter specifically designed to be mounted in series, filter elements designed according to DIN 550 In-line modular filter, available with and up to 6 different heads In-line low pressure filter specifically designed to be mounted in series In-line duplex medium pressure filter In-line duplex low pressure filter In-line duplex modular filter, available with up to 6 different heads In-line and duplex medium pressure filter, filter elements designed according to DIN 550 up to P max bar psi up to Q max l/min gpm page FMP 09 FMP FHP FMM 050 FHA 05 FHM FHB FHF 5 FHD CLOGGING INDICATORS HIGH PRESSURE FILTERS Versatile filter for high pressure - low flow rate applications Versatile filter for high pressure - high flow rate applications Typical high pressure filter for mobile applications FMM 050: Typical high pressure filter for mobile applications FHA 05: Filter optimized for use in high pressure operating systems High pressure filter with intermediate plate construction High pressure for block mounting In-line manifold top mounting In-line duplex high pressure filter up to P max bar psi up to Q max l/min gpm page FZP FZH FZX FZB FZM FZD CLOGGING INDICATORS STAINLESS STEEL HIGH PRESSURE FILTERS In-line pressure filter with threaded mount In-line pressure filter with threaded mount for higher pressure In-line pressure filter with threaded mount up to 000 bar Manifold side mounting Manifold top mounting Duplex pressure filter for continuous operation requirements up to P max bar psi up to Q max l/min gpm page 585 QUICK REFERENCE GUIDE CLOGGING INDICATORS 9 Introduction

12 Introduction 0

13 Introduction Contamination management INDEX HYDRAULIC FLUIDS FLUIDS CONTAMINATION EFFECTS OF CONTAMINATION ON HYDRAULIC COMPONENTS MEASURING THE SOLID CONTAMINATION LEVEL FILTRATION TECHNOLOGIES RECOMMENDED CONTAMINATION CLASSES & FILTER TYPES FILTER SIZING PARAMETERS APPLICABLE STANDARDS FOR FILTER DEVELOPMENT Page Introduction

14 CONTAMINATION MANAGEMENT HYDRAULIC FLUIDS The fl uid is the vector that transmits power, energy within an oleodynamic circuit. In addition to transmitting energy through the circuit, it also performs additional functions such as lubrication, protection and cooling of the surfaces. The classifi cation of fl uids used in hydraulic systems is coded in many regulatory references, different Standards. The most popular classifi cation criterion divides them into the following families: - MINERAL OILS Commonly used oil deriving fl uids. - FIRE RESISTANT FLUIDS Fluids with intrinsic characteristics of incombustibility or high fl ash point. - SYNTHETIC FLUIDS Modifi ed chemical products to obtain specifi c optimized features. - ECOLOGICAL FLUIDS Synthetic or vegetable origin fl uids with high biodegradability characteristics. The choice of fl uid for an hydraulic system must take into account several parameters. These parameters can adversely affect the performance of an hydraulic system, causing delay in the controls, pump cavitation, excessive absorption, excessive temperature rise, effi ciency reduction, increased drainage, wear, jam/block or air intake in the plant. The main properties that characterize hydraulic fl uids and affect their choice are: - DYNAMIC VISCOSITY It identifi es the fl uid s resistance to sliding due to the impact of the particles forming it. - CINEMATIC VISCOSITY It is a widespread formal dimension in the hydraulic fi eld. It is calculated with the ratio between the dynamic viscosity and the fluid density. Cinematic viscosity varies with temperature and pressure variations. - VISCOSITY INDEX This value expresses the ability of a fluid to maintain viscosity when the temperature changes. A high viscosity index indicates the fluid s ability to limit viscosity variations by varying the temperature. - FILTERABILITY INDEX It is the value that indicates the ability of a fluid to cross the filter materials. A low fi lterability index could cause premature clogging of the fi lter material. - WORKING TEMPERATURE Working temperature affects the fundamental characteristics of the fluid. As already seen, some fl uid characteristics, such as cinematic viscosity, vary with the temperature variation. When choosing a hydraulic oil, must therefore be taken into account of the environmental conditions in which the machine will operate. - COMPRESSIBILITY MODULE Every fl uid subjected to a pressure contracts, increasing its density. The compressibility module identifies the increase in pressure required to cause a corresponding increase in density. - HYDROLYTIC STABILITY It is the characteristic that prevents galvanic pairs that can cause wear in the plant/system. - ANTIOXIDANT STABILITY AND WEAR PROTECTION These features translate into the capacity of a hydraulic oil to avoid corrosion of metal elements inside the system. - HEAT TRANSFER CAPACITY It is the characteristic that indicates the capacity of hydraulic oil to exchange heat with the surfaces and then cool them. FLUID CONTAMINATION Whatever the nature and properties of fluids, they are inevitably subject to contamination. Fluid contamination can have two origins: - INITIAL CONTAMINATION Caused by the introduction of contaminated fl uid into the circuit, or by incorrect storage, transport or transfer operations. - PROGRESSIVE CONTAMINATION Caused by factors related to the operation of the system, such as metal surface wear, sealing wear, oxidation or degradation of the fluid, the introduction of contaminants during maintenance, corrosion due to chemical or electrochemical action between fluid and components, cavitation. The contamination of hydraulic systems can be of different nature: - SOLID CONTAMINATION For example rust, slag, metal particles, fi bers, rubber particles, paint particles - or additives - LIQUID CONTAMINATION For example, the presence of water due to condensation or external infi ltration or acids - GASEOUS CONTAMINATION For example, the presence of air due to inadequate oil level in the tank, drainage in suction ducts, incorrect sizing of tubes or tanks. EFFECTS OF CONTAMINATION ON HYDRAULIC COMPONENTS Solid contamination is recognized as the main cause of malfunction, failure and early degradation in hydraulic systems. It is impossible to delete it completely, but it can be effectively controlled by appropriate devices. CONTAMINATION IN PRESENCE OF LARGE TOLERANCES CONTAMINATION IN PRESENCE OF NARROW TOLERANCES Solid contamination mainly causes surface damage and component wear. - ABRASION OF SURFACES Cause of leakage through mechanical seals, reduction of system performance, failures. Introduction

15 CONTAMINATION MANAGEMENT - SURFACE EROSION Cause of leakage through mechanical seals, reduction of system performance, variation in adjustment of control components, failures. - ADHESION OF MOVING PARTS Cause of failure due to lack of lubrication. - DAMAGES DUE TO FATIGUE Cause of breakdowns and components breakdown.stem performance, failures. - SURFACE EROSION Cause of leakage through mechanical seals, reduction of system performance, variation in adjustment of control components, failures. - ADHESION OF MOVING PARTS Cause of failure due to lack of lubrication. - DAMAGES DUE TO FATIGUE Cause of breakdowns and components breakdown. Gaseous contamination mainly results in decay of system performance. - CUSHION SUSPENSION Cause of increased noise and cavitation. - FLUID OXIDATION Cause of corrosion acceleration of metal parts. - MODIFICATION OF FLUID PROPERTIES (COMPRESSIBILITY MODULE, DENSITY, VISCOSITY) Cause of system s reduction of efficiency and of controllability. It is easy to understand how a system without proper contamination management is subject to higher costs than a system that is provided. - MAINTENANCE Maintenance activities, spare parts, machine stop costs - ENERGY AND EFFICIENCY Efficiency and perfomance reduction due to friction, drainage, cavitation. ABRASION EROSION MEASURING THE SOLID CONTAMINATION LEVEL ADHESION FATIGUE The level of contamination of a system identifi es the amount of contaminant contained in a fl uid. This parameter refers to a unit volume of fl uid. The level of contamination may be different at different points in the system. From the information in the previous paragraphs it is also apparent that the level of contamination is heavily infl uenced by the working conditions of the system, by its working years and by the environmental conditions. What is the size of the contaminating particles that we must handle in our hydraulic circuit? Liquid contamination mainly results in decay of lubrication performance and protection of fl uid surfaces. HUMAN HAIR (75 µm) DISSOLVED WATER - INCREASING FLUID ACIDITY Cause of surface corrosion and premature fl uid oxidation - GALVANIC COUPLE AT HIGH TEMPERATURES Cause of corrosion MINIMUM DIMENSION VISIBLE HUMAN EYES (0 µm) FREE WATER - ADDITIONAL EFFECTS - DECAY OF LUBRICANT PERFORMANCE Cause of rust and sludge formation, metal corrosion and increased solid contamination - BATTERY COLONY CREATION Cause of worsening in the fi lterability feature - ICE CREATION AT LOW TEMPERATURES Cause damage to the surface - ADDITIVE DEPLETION Free water retains polar additives TYPICAL CONTAMINANT DIMENSION IN A HYDRAULIC CIRCUIT ( µm) Contamination level analysis is signifi cant only if performed with a uniform and repeatable method, conducted with standard test methods and suitably calibrated equipment. To this end, ISO has issued a set of standards that allowa to conduct tests and express the measured values in the following ways. Introduction

16 CONTAMINATION MANAGEMENT - GRAVIMETRIC LEVEL - ISO 05 The level of contamination is defined by checking the weight of particles collected by a laboratory membrane. The membrane must be cleaned, dried and desiccated, with fluid and conditions defined by the Standard. The volume of fluid is filtered through the membrane by using a suitable suction system. The weight of the contaminant is determined by checking the weight of the membrane before and after the fluid filtration. ISO 06:999 Cleanliness Code System Microscope counting examines the particles differently to APCs and the code is given with two scale numbers only. These are at 5 µm and 5 µm equivalent to the 6 µm (c) and µm (c) of APCs Cleanliness Code Chart with 00 ml sample volume /9/ Example Code /9/ - CUMULATIVE DISTRIBUTION OF THE PARTICLES SIZE - ISO The level of contamination is defined by counting the number of particles of certain dimensions per unit of volume of fluid. Measurement is performed by Automatic Particle Counters (APC). Following the count, the contamination classes are determined, corresponding to the number of particles detected in the unit of fluid. The most common classification methods follow ISO 06 and SAE AS 059 (Aerospace Sector) regulations. NAS 68 is still used although obsolete Classification example according to ISO 06 The code refers to the number of particles of the same size or greater than, 6 or µm in a ml fluid Class > µm (c) = 50 particles > 6 µm (c) = 00 particles > µm (c) = 5 particles 6 / / Number of particles per ml Over Up to Number of particles per 00ml larger than indicated size New ISO 06 standard µm (c) Old standard ISO Code numbers Introduction

17 CONTAMINATION MANAGEMENT - CUMULATIVE DISTRIBUTION OF THE PARTICLES SIZE - SAE AS 059- and SAE AS 059- Classification example according to SAE AS 059- and SAE AS 059- The code, prepared for the aerospace industry, is based on the size, quantity, and particle spacing in a 00 ml fluid sample. The contamination classes are defined by numeric codes, the size of the contaminant is identified by letters (A-F). It can be made a differential measurement (Table ) or a cumulative measurement (Table ) Class Dimension of contaminant 6 µm (c) µm (c) 8 µm (c) 8 70 µm (c) >70 µm (c) µm (c) = particles µm (c) = 00 particles 8 µm (c) = 00 particles 8 70 µm (c) = 5 particles > 70 µm (c) = particles Class 6 Class > µm (c) A >6 µm (c) B > µm (c) = particles > 6 µm (c) = particles > µm (c) = 500 particles > µm (c) = 50 particles > 8 µm (c) = 5 particles > 70 µm (c) = particle Class from F to E Table - Class for differential measurement Table - Class for cumulative measurement Dimension of contaminant > µm (c) C > µm (c) D >8 µm (c) E >70 µm (c) F CLASSES OF CONTAMINATION ACCORDING TO NAS 68 (January 96) The NAS system was originally developed in 96 to define contamination classes for the contamination contained within aircraft components. The application of this standard was extended to industrial hydraulic systems simply because nothing else existed at the time. The coding system defines the maximum numbers permitted of 00ml volume at various size intervals (differential counts) rather than using cumulative counts as in ISO 06:999. Although there is no guidance given in the standard on how to quote the levels, most industrial users quote a single code which is the highest recorded in all sizes and this convention is used on MP Filtri APC s. The contamination classes are defined by a number (from 00 to ) which indicates the maximum number of particles per 00 ml, counted on a differential basis, in a given size bracket. Size Range Classes (in microns) Class Maximum Contamination Limits per 00 ml > µm (c) = 000 particles 5 5 µm (c) = 00 particles 5 50 µm (c) = 50 particles µm (c) = 8 particles > 00 µm (c) = particles Class NAS CUMULATIVE DISTRIBUTION OF THE PARTICLES SIZE - ISO The level of contamination is defined by counting the number of particles collected by a laboratory membrane per unit of fluid volume. The measurement is done by a microscope. The membrane must be cleaned, dried and desiccated, with fluid and conditions defined by the Standard. The fluid volume is filtered through the membrane, using a suitable suction system. The level of contamination is identified by dividing the membrane into a predefined number of areas and by counting the contaminant particles using a suitable laboratory microscope. MICROSCOPE CONTROL AND MEASUREMENT COMPARISON PHOTOGRAPH S graduation = 0µm ISO 06:999 SAE AS059E Table NAS 68 SAE AS059E Table Class 6// Class 5 Class 5 Class 6A/5B/5C Class /0/7 Class Class Class A/B/C 5 Introduction

18 CONTAMINATION MANAGEMENT - CLEANLINESS CODE COMPARISON Although ISO 06:999 standard is being used extensively within the hydraulics industry other standards are occasionally required and a comparison may be requested. The table below gives a very general comparison but often no direct comparison is possible due to the different classes and sizes involved. External protective wire mesh Pre-fi ltration layer Filtration layer Inner support layer Inner protective wire mesh ISO 06:999 / / 8 SAE AS059 Table > µm (c) µm (c) µm (c) 6 µm (c) > µm (c) 6 µm (c) A / B / C SAE AS059 Table >70 NAS >00 MICROFIBER FILTRATION Support S pipe / 0 / 7 / 9 / 6 0 / 8 / 5 9 / 7 / 8 / 6 / 7 / 5 / A / B / C A / 0B / 0C 0A / 9B / 9B 9A / 8B / 8C 8A / 7B / 7C 7A / 6B / 6C The fi ltration effi ciency of metallic mesh fi ltrations is defi ned as the maximum particle size that can pass through the meshes of the fi ltering grid. The effi ciency of microfi bre and paper fi ltration (ß x(c) ) is defi ned through a lab test called Multipass Test. The effi ciency value (ß x(c) ) is defi ned as the ratio between the number of particles of certain dimensions detected upstream and downstream of the fi lter. 6 / / 6A / 5B / 5C / / 0 / / 09 5A / B / C A / B / C Upstream particles number > X µm (c) = ß x(c) Downstream particles number > X µm (c) 5 FILTRATION TECHNOLOGIES Various mechanisms such as mechanical stoppage, magnetism, gravimetric deposit, or centrifugal separation can be used to reduce the level of contamination. The mechanical stoppage method is most effective and can take place in two ways: - SURFACE FILTRATION It is by direct interception. The fi lter prevents particles larger than the pores from continuing in the plant / system. Surface filters are generally manufactured with metal canvases or meshes. Value (ß x(c) ) Efficiency 50% 0 90% % 00 99% % % - DEPTH FILTERING Filters are constructed by fiber interlacing. Such wraps form pathways of different shapes and sizes in which the particles remain trapped when they fi nd smaller apertures than their diameter. Depth fi lters are generally produced with papers impregnated with phenolic resins, metal fi bers or inorganic fi bers. In inorganic fi ber fi ltration, commonly called microfi bre, the fi ltering layers are often overlapped in order to increase the ability to retain the contaminant. Test conditions, such as type of fl uid to be used (MIL-H-5606), type of contaminant to be used (ISO MTD), fl uid viscosity, test temperature, are determined by ISO In addition to the fi ltration effi ciency value during the Multipass test, other important features, such as fi ltration stability (ß stability) and dirt holding capacity (DHC), are also tested. Poor fi ltration stability is the cause of the fi ltering quality worsening as the fi lter life rises. Low dirt holding capacity causes a reduction in the life of the fi lter. WIRE MESH FILTRATION PAPER FILTRATION MP Filtri Filter media code A0 A06 A0 A6 A5 Filtration ISO Standard Comparison ß x(c) > 000 ISO µm (c) 7 µm (c) 0 µm (c) 5 µm (c) µm (c) Introduction 6

19 CONTAMINATION MANAGEMENT 6 RECOMMENDED CONTAMINATION CLASSES Any are the nature and the properties of fl uids, they are inevitably subject to contamination. The level of contamination can be managed by using special components called fi lters. Hydraulic components builders, knowing the problem of contamination, recommend the fi ltration level appropriate to the use of their products. Example of recommended contamination levels Piston pumps with fi xed fl ow rate Piston pumps with variable fl ow rate Vane pumps with fi xed fl ow rate Vane pumps with variable fl ow Engines Hydraulic cylinders Actuators Test benches Check valve Directional valves Flow regulating valves Proportional valves Servo-valves Flat bearings Ball bearings ISO 06 CODE Recommended fi ltration ßx(c).000 The common classifi cation of fi lters is determined by their position in the plant. Types of filters: 0/8/5 ß 0(c) >000 9/7/ ß 5(c) >000 8/6/ 7/5/ ß 0(c) ß 7(c) >000 >000 Suction filters They are positioned before the pump and are responsible for protecting the pump from dirty contaminants. It also provides additional fl ow guidance to the pump suction line. Being subject to negligible working pressures are manufactured with simple and lightweight construction. They are mainly produced with gross grade surface fi ltrations, mainly 60 5 µm. They can be equipped with a magnetic fi lter for retaining ferrous particles. They are generally placed under the fl uid head to take advantage of the piezometric thrust of the fl uid and reduce the risk of cavitation. There are two types of suction fi lters: - IMMERSION FILTERS Simple fi lter element screwed on the suction pipe 6// ß 7(c) >000 - FILTERS WITH CONTAINER Container fi lters that are more bulky, but provide easier maintenance of the tank 5//0 ß 5(c) >000 Delivery (or Pressure) filters They are positioned between the pump and most sensitive regulating and controlling components, such as servo valves or proportional valves, and are designed to ensure the class of contamination required by the components used in the circuit. Being subjected to high working pressures are manufactured with more robust and articulated construction. In particular situations of corrosive environments or aggressive fl uids can be made of stainless steel. They are mainly produced with fi ltering depths of 5 µm. They can be manufactured with in-line connections, with plate or fl ange connections or directly integrated into the circuit control blocks / manifolds. They can also be manufactured in duplex confi guration to allow the contaminated section to be maintained even when the plant / system is in operation without interruption of the working cycle. Return filters They are positioned on the return line to the tank and perform the task of fi ltering the fl uid from particles entering the system from the outside or generated by the wear of the components. They are generally fi xed to the reservoir (for this reason also called top tank mounted), positioned semi-immersed or completely immersed. They are mainly produced with fi ltration depths of 0 5 µm. The positioning of the return fi lters must guarantee in all operating conditions that the fl uid drainage takes place in immersed condition; this is to avoid creating foams in the tank that can cause malfunctions or cavitation in the pumps. For the sizing of the return fi lters, account must be taken of the presence of accumulators or cylinders that can make the return fl ow considerably greater than the pump suction fl ow rate. Being subject to contained working pressures are manufactured with simple and lightweight construction. Normally it is possible to extract the fi lter element without disconnecting the fi lter from the rest of the system. Combined filters They are designed to be applied to systems with two or more circuits. They are commonly used in hydrostatic transmission machines where they have a dual fi ltration function of the return line and suction line of the hydrostatic transmission pump. The fi lter is equipped with a valve that keeps the 0.5 bar pressure inside the fi lter. A portion of the fl uid that returns to the tank is fi ltered by the return fi lter element, generally produced with absolute fi ltration, and returns to the transmission booster pump. Only excess fl uid returns to the tank through the valve. The internal pressure of the fi lter and the absolute fi ltration help to avoid the cavitation phenomenon inside the pump. Off-line filters They are generally used in very large systems / plants, placed in a closed circuit independent from the main circuit. They remain in operation regardless of the operation of the main circuit and are crossed by a constant fl ow rate. They can also be manufactured in duplex confi guration to allow the contaminated section to be maintained even when the unit is in operation without interruption of the work cycle. Venting filters During the operation of the plants, the fl uid level present in the reservoir changes continuously. The result of this continuous fl uctuation is an exchange of air with the outside environment. The venting fi lter function, positioned on the tank, is to fi lter the air that enters the tank to compensate for fl uid level variations. 7 Introduction

20 CONTAMINATION MANAGEMENT FILTER CHOICE PARAMETERS 7 8 APPLICABLE STANDARDS FOR FILTER DEVELOPMENT The choice of the fi lter system for an hydraulic system is infl uenced by several factors. It is necessary to consider the characteristics of the various components present in the plant and their sensitivity to contamination. It is also necessary to consider all the tasks that the fi lter will have to do within the plant: - FLUID PROTECTION FROM CONTAMINATION - PROTECTION OF OLEODYNAMIC COMPONENTS SENSITIVE TO CONTAMINATION - PROTECTION OF OLEODINAMIC PLANTS FROM ENVIRONMENTAL WASTE - PROTECTION OF OLEODINAMIC PLANTS FROM CONTAMINATION CAUSED BY COMPONENTS FAILURES The advantages of proper positioning and sizing of the fi lters are - MORE RELIABILITY OF THE SYSTEM - LONGER LIFE OF THE FLUID COMPONENTS - REDUCTION OF STOP TIME - REDUCTION OF FAILURE CASUALITIES Each hydraulic fi lter is described by general features that identify the possibility of use in different applications. MAXIMUM WORKING PRESSURE (Pmax) The maximum working pressure of the filter must be greater than or equal to the pressure of the circuit section in which it will be installed. PRESSURE DROP (ΔP) The pressure drop depends on a number of factors, such as the working circuit temperature, the fl uid viscosity, the fi lter element cleaning condition. WORKING TEMPERATURE (T) The working temperature deeply affect the choice of materials. Excessively high or low temperatures may adversely affect the strength of the materials or the characteristics of the seals. FILTRATION EFFICIENCY (%) / FILTRATION RATIO (ß x(c) ) Filtration efficiency is the most important parameter to consider when selecting a fi lter. When choosing the filtration performances, the needs of the most sensitive components in the system must be considered. FLUID TYPE The type of fl uid infl uences the choice of fi lters in terms of compatibility and viscosity. It is always mandatory to check the fi lterability. PLACEMENT IN THE PLANT The position of the filter in the system conditions the efficiency of all filter performances. In order to obtain unique criteria for development and verification of the fi lters performance, specifi c regulations for the fi lters and fi lter elements testing have been issued by ISO. These norms describe the target, the methodology, the conditions and the presentation methods for the test results. ISO 9 Hydraulic fl uid power -- Filter elements -- Verifi cation of collapse/burst pressure rating This Standard describes the method for testing the collapse / burst resistance of the fi lter elements. The test is performed by crossing the contaminated fl uid fi lter element at a predefi ned fl ow rate. The progressive clogging of the fi lter element, determined by contamination, causes an increase in differential pressure. ISO 9 Hydraulic fl uid power -- Filter elements -- Verifi cation of fabrication integrity and determination of the fi rst bubble point This Standard describes the method to verify the integrity of the assembled fi lter elements. It can be used to verify the quality of the production process or the quality of the materials by verifying the pressure value of the fi rst bubble point. ISO 9 Hydraulic fl uid power -- Filter elements -- Verifi cation of material compatibility with fl uids This Standard describes the method to verify the compatibility of materials with certain hydraulic fl uids. The test is carried out by keeping the element (the material sample) immersed in the fl uid under high or low temperature conditions for a given period of time and verifying the retention of the characteristics. ISO 7 Hydraulic fl uid power -- Filter elements -- Method for end load test This Standard describes the method for verifying the axial load resistance of the fi lter elements. After performing the procedure described in ISO 9, the designed axial load is applied to the fi lter element. To verify the test results, then the test described in ISO 9 is performed. ISO 968 Hydraulic fl uid power -- Filters -- Evaluation of differential pressure versus fl ow characteristics This Standard describes the method for checking the pressure drop across the fi lter. The test is carried out by crossing the fi lter from a given fl uid and by detecting upstream and downstream pressures. Some of the parameters defi ned by the Standard are the fl uid, the test temperature, the size of the tubes, the position of the pressure detection points. ISO 6889 Hydraulic fl uid power -- Filters -- Multi-pass method for evaluating fi ltration performance of a fi lter element This Standard describes the method to check the fi ltration characteristics of the fi lter elements. The test is performed by constant introduction of contaminant (ISO MTD). The characteristics observed during the test are the fi ltration effi ciency and the dirty holding capacity related to the differential pressure. Introduction 8

21 CONTAMINATION MANAGEMENT ISO 8 Hydraulic fluid power -- Filter elements -- Determination of resistance to flow fatigue using high viscosity fluid This Standard describes the method for testing the fatigue resistance of the filter elements. The test is carried out by subjecting the filter to continuous flow variations, thus differential pressure, using a high viscosity fluid. ISO 70 Hydraulic fluid power -- Sequence of tests for verifying performance characteristics of filter elements The Standard describes the method for testing the performance of filter elements. The protocol described by the regulations provides the sequence of all the tests described above in order to verify all the working characteristics (mechanical, hydraulic and filtration). ISO 077- Hydraulic fluid power -- Fatigue pressure testing of metal pressure-containing envelopes -- Test method This Standard describes the method to check the resistance of the hydraulic components with pulsing pressure. It can be applied to all metal components (excluding tubes) subject to cyclic pressure used in the hydraulic field. 9 Introduction

22 FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range bar. The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the housing is proportional to the fluid density (kg/dm ); all the graphs in the catalogue are referred to mineral oil with density of 0.86 kg/dm. The filter element pressure drop is proportional to its viscosity (mm /s), the corrective factor Y is related to an oil viscosity different than 0 mm /s. Sizing data for single cartridge, head at top pc = Filter housing pressure drop [bar] pe = Filter element pressure drop [bar] Y = Multiplication factor Y (see correspondent table), depending on the filter element size, on the filter element lenght and on the filter media Q = flow rate (l/min) V reference viscosity = 0 mm /s (cst) V = operating viscosity in mm /s (cst) pe = Y : 000 x Q x (V/V) p Tot. = pc + pe Calculation examples with HLP Mineral oil Variation in viscosity Application data: Top tank return filter Filter with in-line connections Pressure Pmax = 0 bar Flow rate Q = 0 l/min Viscosity V = 6 mm /s (cst) Oil viscosity = 0.86 kg/dm Required filtration efficiency = 5 μm with absolute filtration With bypass valve and / inlet connection From the working pressure and the flow rate we understand it should be possible using the following top tank return filter series: MPT, MPH and FRI. Let s proceed with MPT series. The size 0 doesn t achieve the required flow rate, therefore we have to consider the size 00. The final version of size 00 (0, 0, 0, 0 and ) will be then defined in function of the mounting characteristics. pc = 0.0 bar ( see graphic below, considering size 00 with the max available lenght * to get the lowest pressure drop) pe = (.0 : 000) x 0 x (6/0) = 0.7 bar p Tot. = = 0. bar The selection is correct because the total pressure drop value is inside the admissible range for top tank return filters. It is of course possible trying to find a different solution, according to the mounting position or to other commercial need, repeating the previous steps while using a different series or lenght. Δp bar MPT 0 - Length * G / Flow rate l/min Filter housings p pressure drop. The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s Return filters Filter element Type MF 00 MF 00 MFX 00 MF 00 MFX 00 MF 80 MFX 80 MF 90 MFX 90 MF 00 MFX 00 MF 750 MFX 750 CU 05 CU 00 CU 00 CU 50 CU 60 CU 850 MR 00 MR 50 MR 60 MR A Absolute filtration Nominal filtration H Series N Series A06 A0 A6 A5 P0 P5 M5 M60 M Introduction 0

23 Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s Suction filters Filter element Type SF 50 Nominal filtration N Series P0 P5 65 Low & Medium pressure filters Filter element Type CU 0 A FILTER SIZING Absolute filtration Nominal filtration N-W Series N Series A06 A0 A6 A5 P0 P5 M Return / Suction filters Filter element Type RSX 6 A0 5.. Absolute filtration A6..87 A5.85. CU 0 DN RSX CU CU CU MR Introduction

24 FILTER SIZING Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s High pressure filters Filter element Type HP 0 A Absolute filtration N - R Series A06 A0 A A Nominal filtration N Series M Stainless steel high pressure filters Filter element Type HP 0 A Absolute filtration N Series A06 A0 A A HP HP HP HP HP HP HP 5 HP Filter element Type HP 0 A Absolute filtration H - U Series A06 A0 A A HP HP Filter element Type A0 Absolute filtration N Series A06 A0 A6 A5 Nominal filtration N Series M5 HP HF HP Introduction

25 Selection Software FILTER SIZING Step Select FILTERS Step Choose fi lter group (Return Filter, Pressure Filter, etc.) Step Choose fi lter type (MPF, MPT, etc.) in function of the max working pressure and the max fl ow rate Step Push PROCEED Step 5 Insert all application data to calculate the fi lter size following the sequence: - working pressure - working fl ow rate - working pressure drop - working temperature - fl uid material and fl uid type - fi ltration media - connection type Step 6 Push CALCULATE to have result; in case of any mistake, the system will advice which parameter is out of range to allow to modify/adjust the selection Step 7 Download PDF Datasheet Report.aspx pushing the button Drawing Introduction

26 LMP - low and medium pressure filters are used as process filters to protect pumps, pressure reducers and hydraulic circuits from damage due to oil contamination as per ISO 06. LMP series is available in 5 different sizes: 00, 00, 00, 900 and 950 and a wide range of versions. LMP filters are available with several working pressures suitable for all hydraulic circuits as: - return filters in external tank mounting construction for medium and high flow rates in single and duplex versions - in-line filters for low and medium pressures for off-line applications - in-line process filters for medium pressures, for example, for forced lubrication applications, in single or duplex versions - in-line filters for medium pressures for filtering hydraulic boost circuits - in-line filters as high holding capacity filters on test beds LMP filters are thus specifically designed to be suitable for a wide range of application: from steel plants to mobile equipments, from test benches to naval application, providing the right solution for filtering requirements in all sectors. LMP filters are available in single, manifold and duplex versions. FILTER SIZING For the proper corrective factor Y see chapter at page Low & Medium Pressure filters 0

27 Low & Medium Pressure filters LMP 0-0 MULTIPORT LMP 0 - LMP LMP LMP LMP LMP page 05 LMD LMD LMD 95 page LDP - LDD page 09 Filter element according to DIN INDICATORS page 8 0 Low & Medium Pressure filters

28 Low & Medium Pressure filters 0

29 Low & Medium Pressure fi lters LMP 0-0 series MULTIPORT Maximum pressure up to 80 bar - Flow rate up to 00 l/min 05 Low & Medium Pressure filters

30 LMP 0-0 MULTIPORT GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 80 bar - Flow rate up to 00 l/min Filter housing materials - Head: Aluminium - Housing: Cataphoresis - Painted Steel - Bypass valve: Brass - Aluminium Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 8 MPa (80 bar) - Test pressure: MPa (0 bar) - Burst pressure: LMP 0: 9 MPa (90 bar) LMP 0/0: 8 MPa (80 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to 8 MPa (80 bar) Temperature From -5 C to +0 C Note LMP MULTIPORT filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: 0 bar - Wire mesh filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMP 0 LMP 0 LMP Length Weights [kg] Length Volumes [dm ] Low & Medium Pressure filters 06

31 GENERAL INFORMATION LMP 0-0 MULTIPORT Multiport LMP 0 LMP 0 In-Line fi lter Port IN-OUT on the same side LMP Double IN port LMP Lateral OUT port high fl ow LMP 6 Double OUT port Type LMP Bypass valve for heat exchanger high fl ow C B A LMP 8 Bypass lateral. Always cleaning fl uid in OUT port Type C B A LMP 9 Safety valve 6 bar for heat exchanger 07 Low & Medium Pressure filters

32 LMP 0 LMP / LMP / / 0.9 / LMP MULTIPORT LMP LMP 8 - Setting.5 bar The curves are plotted using mineral oil 8 Pressure drop / / with density of 0.86 kg/dm in compliance with ISO p varies proportionally with density Flow rate l/min Flow rate l/min Flow rate l/min Δp bar Δp bar LMP LMP / Flow rate OUT / l/min OUT / LMP LMP Setting.5 bar / Δp Δp bar bar Δp bar Δp bar Δp bar Δp bar Δp bar Flow Flow rate rate l/min l/min Flow rate l/min LMP IN LMP Setting.5 bar 0.99 LMP / A>C A>B Flow rate l/min Flow Flow rate rate l/min l/min Δp bar Δp bar Δp bar Δp bar Δp Δp bar bar A>C A>B GENERAL INFORMATION 0.6 Filter housings Valves Valves p pressure drop 0 LMP Bypass valve pressure drop Bypass valve pressure drop OUT OUT Flow LMP rate 0 / l/min Setting.5 bar LMP - Filter housing wit 0.6 LMP Setting.5 bar Flow rate l/min Flow rate l/min Flow rate l/min 0.9 LMP LMP LMP 0 - Setting 6 bar / / IN / Δp bar Δp bar Δp bar Flow Flow rate rate l/min l/min Flow rate l/min Δp bar LMP Δp Δp bar bar Flow rate Flow Flow rate LMP 0 - Setting 6 bar 8 LMP - Filter housing wi 8 Δp Δp bar bar Flow Flow rate rat Valves Bypass valve LMP 0 0.9pressure drop / LMP Setting.5 bar 0.6 Δp bar Δp bar Flow rate l/min Flow rate l/min Δp bar Δp bar LMP 0.9 A>C LMP - Filter housing with bar check valve A>B A>C A>B Flow rate l/min es Flow rate l/min LMP LMP Setting Filter housing 6 bar with bar check valve 8 A>C 8 Δp bar Δp bar 6 A>B Δp bar 8 LMP - Filter housing with bar check valve A>C A>B Flow Flow rate rate l/min Flow rate l/min Δp bar 8 LMP - Filter housing with bar check valve A>C A>B Flow rate l/min Low & Medium Pressure filters 08

33 GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP 0-0 MULTIPORT Pressure drop LMP Setting.5 bar 8 LMP 8 - Setting.5 bar Bypass valve pressure drop Δp bar 8 Δp bar Flow rate l/min Flow rate l/min Flow rate l/min 9 LMP Setting.5 bar Δp bar Flow rate l/min 09 Low & Medium Pressure filters

34 LMP MULTIPORT Designation & Ordering code LMP0 - LMP - LMP6 Series and size LMP0 LMP LMP6 Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D A0 N P0 Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN Aux (only LMP - 6) G/ G/ / NPT / NPT SAE - /6 - UN SAE - /6 - UN Connection for differential indicator Without With standard connection With connection on the opposite side 6 With two connections on both sides Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Additional features page T Plug ACCESSORIES Execution P0 MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Low & Medium Pressure filters 0

35 LMP0 - LMP - LMP6 LMP MULTIPORT Dimensions LMP0 - LMP LMP6 Filter length H [mm] Recommended clearance space for maintenance Low & Medium Pressure filters

36 LMP MULTIPORT Designation & Ordering code LMP8 - LMP9 Series and size LMP8 LMP9 Length Bypass valve B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP8 B A D A0 N P0 Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN Aux OUT G/ G/ / NPT / NPT SAE - /6 - UN SAE - /6 - UN Connection for differential indicator Without With standard connection Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

37 LMP8 - LMP9 LMP MULTIPORT Dimensions LMP8 - LMP9 Filter length H [mm] Recommended clearance space for maintenance Low & Medium Pressure filters

38 LMP MULTIPORT Designation & Ordering code LMP0 - LMP Series and size LMP0 LMP Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D A0 N P0 Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN LMP0 LMP Connection for differential indicator Without With standard connection Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

39 LMP0 - LMP Filter length LMP MULTIPORT LMP0 Dimensions H [mm] Connections A - B C - D - E - F R M0 /8 UNC Recommended clearance space Recommended for maintenance clearance space for maintenance Filter length LMP H [mm] Connections B D - F R M0 /8 UNC Recommended clearance space for maintenance 5 Low & Medium Pressure filters

40 LMP MULTIPORT LMP Designation & Ordering code Series and size LMP Length COMPLETE FILTER Configuration example: LMP R A F A0 N P0 Valves C D G H M N Q R Bypass OUT to cooler Check valve without front bar bar side bar bar.5 bar front bar bar side bar bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections B F G SAE 6-5/6 - UN Connection for differential indicator Without With standard connection Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Additional features page T Plug ACCESSORIES Execution P0 MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Low & Medium Pressure filters 6

41 LMP Filter length LMP MULTIPORT LMP Dimensions H [mm] Connections B F R M0 /8 UNC Recommended clearance space for maintenance 7 Low & Medium Pressure filters

42 LMP 0-0 MULTIPORT Order number for spare parts SPARE PARTS LMP LMP 0 LMP - c d d c d c a a a b b b Item: Filter series LMP LMP 0 LMP - Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table TH TV Low & Medium Pressure filters 8

43 LMP 0-0 MULTIPORT 9 Low & Medium Pressure filters

44 Low & Medium Pressure filters 0

45 Low & Medium Pressure fi lters LMP 0- Maximum pressure up to 60 bar - Flow rate up to 0 l/min Low & Medium Pressure filters

46 LMP0- GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 60 bar - Flow rate up to 0 l/min Filter housing materials - Head: Aluminium - Bowl: Cataphoretic Painted Steel - Bypass valve: AISI 0 - Nylon Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to 6 MPa (60 bar) Temperature From -5 C to +0 C Connections Inlet/Outlet In-Line Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LMP 0 - filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] Weights [kg] Volumes [dm ] Length Length LMP Hydraulic symbols LMP execution S LMP execution B Low & Medium Pressure filters

47 GENERAL INFORMATION LMP0- The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop LMP 0 Δp Housing / / LMP Δp Housing / / Filter housings p pressure drop Δp bar 0. Δp bar Flow rate l/min Flow rate l/min 9 LMP 0/ Bypass valve pressure drop Δp bar Flow rate l/min Low & Medium Pressure filters

48 LMP0 Designation & Ordering code COMPLETE FILTER Series and size LMP0 Configuration example: LMP0 B A F A0 N P0 Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections F SAE 000 psi/m F / SAE 000 psi/m F / SAE 000 psi/m F SAE 000 psi/unc F5 / SAE 000 psi/unc F6 / SAE 000 psi/unc Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

49 LMP0 Filter length LMP0 Dimensions H [mm] Connections F - F - F F - F5 - F6 R M8 5/6 UNC Drain plug only length Recommended clearance space for maintenance 5 Low & Medium Pressure filters

50 LMP Designation & Ordering code Series and size LMP Length Bypass valve S Without bypass Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Connections A G B G / C G / D NPT E / NPT F / NPT G SAE 6-5/6 - UN H SAE 0-5/8 - UN I SAE - 7/8 - UN Connection for differential indicator 6 With plugged connection B.5 bar COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D 6 A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 6

51 LMP Filter length LMP Dimensions H [mm] Connections A-B-C D-E-F-G-H-I R M8 5/6 UNC Drain plug only length Recommended clearance space for maintenance 7 Low & Medium Pressure filters

52 LMP0- Order number for spare parts SPARE PARTS LMP 0 LMP c c d d a a b b Item: Filter series LMP 0 - Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table TH TV Low & Medium Pressure filters 8

53 LMP0-9 Low & Medium Pressure filters

54 Low & Medium Pressure filters 0

55 Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters

56 LMP00-0& 0- GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 60 bar - Flow rate up to 70 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Bypass valve: Steel Seals - Standard NBR series A - Optional FPM series V Pressure LMP 00 length Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to 6 MPa (60 bar) Pressure LMP 00 length Working pressure: 5 MPa (50 bar) - Test pressure: 7.5 MPa (75 bar) - Burst pressure: 5 MPa (50 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to 5 MPa (50 bar) Temperature From -5 C to +0 C Connections LMP 00-0: In-line Inlet/Outlet LMP 0 - : 90 Inlet/Outlet Note LMP 00 filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMP Length Weights [kg] Volumes [dm ] Length Hydraulic symbols LMP execution S LMP execution B Low & Medium Pressure filters

57 GENERAL INFORMATION LMP00-0& 0- The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.9 LMP Filter housings p pressure drop Δp bar G G - F F Flow rate l/min 9 LMP Bypass valve pressure drop Δp bar Flow rate l/min EXECUTION P Execution P0 Internal tube for reduced flow rate is recommended for flow rate values below 00/50 I/min. The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates Low & Medium Pressure filters

58 LMP00-0 Designation & Ordering code COMPLETE FILTER Series and size LMP00 LMP0 Configuration example: LMP0 B A G A0 N P0 Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections G G/ G G G / NPT G NPT G5 SAE - 7/8 - UN G6 SAE - / - UN F F F F SAE 000 psi/m / SAE 000 psi/m SAE 000 psi/unc / SAE 000 psi/unc Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 Maintenance from the bottom of the housing Pxx Customized Filter length 5 6 Element series and size CU00 FILTER ELEMENT Configuration example: CU00 A0 A N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

59 LMP00-0 LMP00 Dimensions Length - - Filter H length [mm] Connections G-G G-G-G5-G6 F-F F-F Recommended clearance space for maintenance Recommended clearance space for maintenance R M / UNC M / UNC Filter length 5 6 LMP00 Length 5-6 H [mm] H Execution [mm] P0 P Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC H - Recommended clearance space for maintenance 5 Low & Medium Pressure filters

60 LMP00-0 Dimensions LMP0 Length - - Filter H length [mm] Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC Recommended clearance space for maintenance Recommended clearance space for maintenance Filter length 5 6 LMP0 Length 5-6 H [mm] H Execution [mm] P0 P Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC H - Recommended clearance space for maintenance Low & Medium Pressure filters 6

61 LMP Low & Medium Pressure filters

62 LMP0- Designation & Ordering code COMPLETE FILTER Series and size LMP0 LMP Configuration example: LMP 5 B A G A0 N P0 Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections G G / G G G / NPT G NPT G5 SAE - 7/8 - UN G6 SAE - / - UN F F F F SAE 000 psi/m / SAE 000 psi/m SAE 000 psi/unc / SAE 000 psi/unc Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 With internal reduced flow rate tube Pxx Customized Element series and size CU00 FILTER ELEMENT Configuration example: CU00 5 A0 A N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 8

63 LMP0- H - Recommended clearance space for maintenance H - Recommended clearance space for maintenance Filter length 5 6 LMP0 H [mm] Connections G-G G-G-G5-G6 F-F F-F Dimensions H [mm] R M / UNC M / UNC Filter length 5 6 LMP H [mm] H [mm] H - Recommended clearance space for maintenance Connections G-G G-G-G5-G6 F-F F-F R M / UNC M / UNC 9 Low & Medium Pressure filters

64 LMP00-0& 0- Order number for spare parts SPARE PARTS LMP 00-0 length - - c d e d f c a LMP 00-0 b LMP 0 - length 5-6 length 5-6 c d f e f d c b 5 a g a b a a b 6 5 c b d g g c d Item: Filter series LMP 00-0 length - - LMP 00-0 length 5-6 LMP 0 - lenght 5-6 Q.ty: pc. Q.ty: pc. Q.ty: pcs. Q.ty: pcs. Q.ty: pc. (a g) 5 6 Filter Seal Kit code number Indicator connection plug Housing spigot Tube element NBR FPM NBR FPM no bypass with bypass assembly See order TH TV 0008 table Length 5: 0050 Length 6: 0050 Low & Medium Pressure filters 0

65 LMP00-0& 0- Low & Medium Pressure filters

66 Low & Medium Pressure filters

67 Low & Medium Pressure fi lters LMP series Filter element according to DIN 550 Maximum pressure up to 0 bar - Flow rate up to 000 l/min Low & Medium Pressure filters

68 LMP GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 0 bar - Flow rate up to 000 l/min Filter element according to DIN 550 Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Anodized Aluminium - Bypass valve: Steel Pressure - Working pressure: MPa (0 bar) - Test pressure:.5 MPa (5 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to MPa (0 bar) Number of filter elements LMP 900-: filter element CU900 LMP 900-: filter elements CU900 Filter elements Filter element in according to with DIN 550 Size: 000 p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Seals - Standard NBR series A - Optional FPM series V Temperature From -5 C to +0 C Note LMP filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Connections LMP 900: In-line Inlet/Outlet LMP 90: 90 Inlet/Outlet Weights [kg] and volumes [dm ] LMP Length Weights [kg] Length Volumes [dm ] 6 Hydraulic symbols LMP execution S LMP execution B Low & Medium Pressure filters

69 GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP Pressure drop 0.6 LMP 900/90 - F LMP 900/90 - F - Filter housings p pressure drop Δp bar LMP 900 F - LMP 90 F - Δp bar LMP 900 F - LMP 90 F Flow rate l/min Flow rate l/min 9 LMP Bypass valve pressure drop Δp bar Flow rate l/min P EXECUTION LMP filters are equipped with two 000 size cartridges in compliance with DIN 550 standard, connected by means of a removable coupling spigot. Coupling spigot 5 Low & Medium Pressure filters

70 LMP Designation & Ordering code COMPLETE FILTER Series and size LMP900 LMP90 Configuration example: LMP90 B A F A0 N P0 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM Connections F SAE 000 psi/m F SAE 000 psi/unc F SAE 000 psi/m F SAE 000 psi/unc B.5 bar Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 Maintenance from the bottom of the housing Pxx Customized Filter length Element series and size CU900 FILTER ELEMENT Configuration example: CU900 A0 A N P0 Length Nr. filter element Nr. filter elements Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A NBR V FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 6

71 LMP Connections F - F F - F LMP900 Length Dimensions R M6 5/8 UNC Recommended clearance space Recommended for maintenance clearance space for maintenance LMP900 Length H Execution [mm] P0 0 P0 800 Connections F - F F - F R M6 5/8 UNC H - Recommended clearance space for maintenance 7 Low & Medium Pressure filters

72 LMP Dimensions Connections F - F F - F LMP90 Length R M6 5/8 UNC 6 6 Recommended clearance space Recommended for maintenance clearance space for maintenance LMP90 Length H Execution [mm] P0 0 P0 800 Connections F - F F - F R M6 5/8 UNC 05 H - Recommended clearance space for maintenance Low & Medium Pressure filters 8

73 SPARE PARTS LMP Order number for spare parts LMP LMP length length c d c d d d e c e c a a b b a 6 a 5 g a 5 b g Item: (a g) 5 6 Filter Filter element Seal Kit code number Indicator connection plug Housing spigot Coupling spigot series Q.ty Q.ty NBR FPM Q.ty NBR FPM Q.ty Q.ty LMP length pc. See pc pcs. pc. - order TH TV LMP length pcs. table pc pcs. pc. pc. 9 Low & Medium Pressure filters

74 Low & Medium Pressure filters 50

75 Low & Medium Pressure fi lters LMP series Filter element according to DIN 550 Maximum pressure up to 0 bar - Flow rate up to 000 l/min 5 Low & Medium Pressure filters

76 LMP90-90 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 0 bar - Flow rate up to 000 l/min Filter element according to DIN 550 Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Welded - Phosphated Steel - Bypass valve: Steel - Size 000 filter elements complying with DIN 550 standard Number of filter elements LMP 90: filter elements CU900 LMP 90: 6 filter elements CU900 Filter elements Filter element in according to with DIN 550 Size: 000 Seals - Standard NBR series A - Optional FPM series V Temperature From -5 C to +0 C Pressure - Working pressure:.5 MPa (5 bar) - Test pressure:.5 MPa (5 bar) p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Note LMP filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Connections LMP 90-90: In-line Inlet/Outlet Weights [kg] and volumes [dm ] LMP 90 LMP 90 Weights [kg] Length Volumes [dm ] Length Hydraulic symbols LMP LMP LMP 95 Manifolds Position of manifolds IN - OUT connections FA FB FC FD Low & Medium Pressure filters 5

77 GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP90-90 Pressure drop 0.6 LMP Filter housings p pressure drop Δp bar LMP 90 LMP Flow rate l/min 9 LMP Bypass valve pressure drop Δp bar Flow rate l/min Focus on: Indicator port Plug T - A/F 0 Bypass valve A/F 7 Oil drain plug G/ - A/F 0 5 Low & Medium Pressure filters

78 LMP90-90 Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMP90 B A FA A0 N P0 LMP90 LMP90 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM B.5 bar Connections IN FA FB SAE 000 psi SAE 000 psi left left FC FD SAE 000 psi SAE 000 psi right right OUT left right left right Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU900 FILTER ELEMENT Configuration example: CU900 A0 A N P0 Filter series and size LMP90 Nr. filter elements LMP90 Nr. 6 filter elements Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A NBR V FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 5

79 LMP90-90 LMP90 Dimensions 55 Low & Medium Pressure filters

80 LMP90-90 Dimensions LMP90 Low & Medium Pressure filters 56

81 SPARE PARTS LMP90-90 Order number for spare parts LMP d 6b 6c 6c 6 6b 6a 5 5a 5b 7 Item 7: for complete fi lter code and spare parts, see LMP series chapter Quantity: - fi lter spare parts: LMP 90 - pcs. LMP 90 - pcs. - fi lter seal kit: LMP 90 - pcs. LMP 90 - pcs. Item: 5 (5a-5b) 6 (6a 6d) 7 Filter Manifold SAE 000 psi plugged flange Manifolds seal kit Threaded fasteners kit Filter series Q.ty IN OUT Q.ty Q.ty NBR FPM Q.ty Q.ty LMP 90 pc pcs. pc pc pcs. 000 LMP90xxFxxxNP0 LMP 90 pc pcs. pc pc pcs. 57 Low & Medium Pressure filters

82 Low & Medium Pressure filters 58

83 Low & Medium Pressure fi lters LMP series Maximum pressure up to 0 bar - Flow rate up to 00 l/min 59 Low & Medium Pressure filters

84 LMP GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 0 bar - Flow rate up to 00 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Bypass valve: Anodized Aluminium Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: MPa (0 bar) - Test pressure:,5 MPa (5 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to MPa (0 bar) Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Temperature From -5 C to +0 C Connections LMP 950: In-line Inlet/Outlet LMP 95: 90 Inlet/Outlet Note LMP filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] Weights [kg] Volumes [dm ] Length Length LMP Hydraulic symbols LMP execution S LMP execution B Low & Medium Pressure filters 60

85 GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP Pressure drop 0.6 LMP 950/95 - F LMP 950/95 - F - Filter housings p pressure drop Δp bar LMP 950 F - LMP 95 F - Δp bar LMP 950 F - LMP 95 F Flow rate l/min Flow rate l/min 6 LMP Bypass valve pressure drop Δp bar Flow rate l/min P EXECUTION Execution P0 Internal tube for reduced flow rate recommended for flow rate values below 00/50 I/min. The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates 6 Low & Medium Pressure filters

86 LMP Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMP95 B A F A0 N P0 LMP950 LMP95 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM Connections F SAE 000 psi/m F SAE 000 psi/unc F SAE 000 psi/m F SAE 000 psi/unc B.5 bar Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar P0 P0 Pxx Execution MP Filtri standard With internal reduced flow rate tube Customized Element series and size CU950 FILTER ELEMENT Configuration example: CU950 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A V NBR FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 6

87 LMP H - Recommended clearance space for maintenance H - Recommended clearance space for maintenance Filter length Connections F - F F - F LMP950 H [mm] Dimensions H [mm] R M6 5/8 UNC Filter length LMP95 H [mm] H [mm] H - Recommended clearance space for maintenance Connections F - F F - F R M6 5/8 UNC 6 Low & Medium Pressure filters

88 LMP SPARE PARTS Order number for spare parts LMP g b 5 a a 6 a 7 b a c d f c d Item: Filter series LMP length - Q.ty: pcs. Q.ty: pc. Q.ty: pcs. Q.ty: pc. Q.ty: pc. Q.ty: pc. (a g) Filter Seal Kit code number Indicator connection plug Housing spigot Coupling Tube assembly element NBR FPM NBR FPM no bypass with bypass spigot length length See order table TH TV Low & Medium Pressure filters 6

89 LMP Low & Medium Pressure filters

90 Low & Medium Pressure filters 66

91 Low & Medium Pressure fi lters LMP series Maximum pressure up to 5 bar - Flow rate up to 000 l/min 67 Low & Medium Pressure filters

92 LMP GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 5 bar - Flow rate up to 000 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Welded - Phosphated Steel - Bypass valve: Anodized Aluminium Number of filter elements - LMP 95: filter elements CU LMP 95: filter elements CU LMP 95: filter elements CU950- Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure:.5 MPa (5 bar) - Test pressure:.5 MPa (5 bar) Temperature From -5 C to +0 C Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Connections LMP : In-line Inlet/Outlet p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Note LMP filters are provided for vertical mounting Weights [kg] and volumes [dm ] LMP 95 LMP 95 LMP 95 Weights [kg] Length Volumes [dm ] Length Hydraulic symbols LMP LMP LMP 95 Manifolds FA Position of manifolds IN - OUT connections Low & Medium Pressure filters 68

93 GENERAL INFORMATION The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP Pressure drop 0.6 LMP LMP 95 Filter housings p pressure drop Δp bar 0. Δp bar Flow rate l/min Flow rate l/min 0.6 LMP Δp bar Flow rate l/min Δp bar LMP 95 A0 A06 A0 A6 A5 M5 Δp bar LMP 95 A0 A06 A0 A6 A5 M5 Pressure drop of filter complete with cartridge, oil viscosity 0 mm /s (cst) Flow rate l/min Flow rate l/min Δp bar LMP 95 A0 A06 A0 A6 A5 M Flow rate l/min 6 LMP Bypass valve pressure drop Δp bar Low & Medium Pressure filters

94 LMP GENERAL INFORMATION Options P EXECUTION Execution P0 Internal tube for reduced flow rate is recommended for flow rate values below: LMP l/min LMP l/min LMP l/min The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates CMV & CUV FLANGE OPTION Flange with oil drain plug for rapid discharge Oil drain plug Code Thread Materials CMV CUV G / SAE 0 - SAE flange - O-R 7 (FPM) for flange - Plug G -/ - O-R 68 for plug (FPM) 5 - No. Hex bolt screws UNI-EN 07 M6 x No. Spring washers UNI 75-B No. Nuts UNI M6 - SAE flange - O-R 7 (FPM) for flange - Plug SAE 0 5/8 - UN - 7 O-R for plug (FPM) 5 - No. Hex bolt screws 5/8 UNC x / 6 - No. Spring washers UNI 75-B No. Nuts 5/8 UNC Low & Medium Pressure filters 70

95 GENERAL INFORMATION LMP Focus on: Breather plug G/ - A/F 0 Oil drain plug G/ - A/F 0 Indicator port Plug T - A/F 0 Indicator port - Plug T - A/F 0 Oil drain plug - G/ - A/F 0 7 Low & Medium Pressure filters

96 LMP Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMP95 B A FA A0 N P0 LMP95 LMP95 LMP95 Length Bypass valve S Without bypass Seals and treatments A NBR V FPM Connections FA SAE 000 psi B.5 bar Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Element p N 0 bar P0 P0 Pxx Execution MP Filtri standard With internal reduced flow rate tube Customized Element series and size CU950 FILTER ELEMENT Configuration example: CU950 A0 A N P0 Element length Filter series and size LMP95 Nr. filter elements LMP95 Nr. filter elements LMP95 Nr. filter elements Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm Seals A V NBR FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 7

97 LMP LMP95 Dimensions 7 Low & Medium Pressure filters

98 LMP Dimensions LMP95 Low & Medium Pressure filters 7

99 LMP LMP95 Dimensions 75 Low & Medium Pressure filters

100 LMP SPARE PARTS Order number for spare parts LMP b 5a 6d 6 6b 6c 6c 6b 6a Item 7: for complete fi lter code and spare parts, see LMP series chapter Quantity: - fi lter spare parts: LMP 95 - pcs. LMP 95 - pcs. LMP 95 - pcs. - fi lter seal kit: LMP 95 - pcs. LMP 95 - pcs. LMP 95 - pcs. Item: 5 (5a-5b) 6 (6a 6d) 7 Filter Manifold SAE 000 psi plugged flange Manifolds seal kit Threaded fasteners kit Filter series Q.ty IN OUT Q.ty Q.ty NBR FPM Q.ty Q.ty LMP 95 pc pcs. pc pc pcs. LMP 95 pc pcs. 000 pc pc pcs. LMP95xxFxxxNP0x LMP 95 pcs pcs. pc pc pcs. Low & Medium Pressure filters 76

101 LMP Low & Medium Pressure filters

102 Low & Medium Pressure filters 78

103 Low & Medium Pressure fi lters LMD series Maximum pressure up to 60 bar - Flow rate up to 0 l/min 79 Low & Medium Pressure filters

104 LMD GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 60 bar - Flow rate up to 0 l/min Filter housing materials - Head: Aluminium - Bowl: Cataphoretic Painted Steel - Bypass valve: AISI 0 - Nylon Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to 6 MPa (60 bar) Temperature From -5 C to +0 C Connections Inlet/Outlet In-Line Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LMD 0 - filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] Weights [kg] Volumes [dm ] Length Length LMD Hydraulic symbols Style S Style B Low & Medium Pressure filters 80

105 GENERAL INFORMATION LMD The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.9 LMD Δp Housing Filter housings p pressure drop Δp bar Flow rate l/min 9 LMD Bypass valve pressure drop Δp bar Flow rate l/min 8 Low & Medium Pressure filters

106 LMD Designation & Ordering code Series and size LMD Length Bypass valve S Without bypass Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC B.5 bar Connections C G / F / NPT I SAE - 7/8 - UN L / SAE 000 psi/m + G / M / SAE 000 psi/unc + / NPT N / SAE 000 psi/unc + SAE 0-5/8 UN Connection for differential indicator 6 With plugged connection COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMD B A C 6 A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size CU0 FILTER ELEMENT Configuration example: CU0 A0 A N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 8

107 LMD Filter length LMD Dimensions H [mm] Connections C F - I L M - N R M0 /8 UNC M0 /8 UNC Recommended clearance space for maintenance 8 Low & Medium Pressure filters

108 LMD Order number for spare parts SPARE PARTS LMD c d e f g h a b Item: Filter series LDD Q.ty: pc. Q.ty: pc. Q.ty: pcs. (a h) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table TH TV Low & Medium Pressure filters 8

109 LMD 85 Low & Medium Pressure filters

110 Low & Medium Pressure filters 86

111 Low & Medium Pressure fi lters LMD 00-0 & series Maximum pressure up to 6 bar - Flow rate up to 590 l/min 87 Low & Medium Pressure filters

112 LMD00-0 & Technical data GENERAL INFORMATION Low & Medium Pressure filters Maximum pressure up to 6 bar - Flow rate up to 590 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Steel - Painted black - Bypass valve: Steel - -way ball valve: Steel housings - Stainless Steel ball - Valve: Phosphated Steel - Stainless Steel Pressure - Working pressure:.6 MPa (6 bar) - Test pressure:.5 MPa (5 bar) Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: 0 bar - Fluid flow through the filter element from OUT to IN. Seals FPM series V Temperature From -5 C to +0 C Connections - LMD 00-0: In-line Inlet/Outlet - LMD 0: Same side - LMD 00-0-: In-Line Note LMP filters are provided for vertical mounting Weights [kg] and volumes [dm ] LMD 00-0 LMD Length 60 - Weights [kg] Length 0 - Volumes [dm ] Hydraulic symbols LMD P EXECUTION Execution P0 Internal tube for reduced flow rate is recommended for flow rate values below 50 I/min. The use of option P0 makes it easier to fill the housing with the operating fluid. Internal tube for reduced flow rates Low & Medium Pressure filters 88

113 GENERAL INFORMATION LMD00-0 & The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop 0.6 LMD Filter housings p pressure drop Δp bar Flow rate l/min 9 LMD Bypass valve pressure drop Δp bar Flow rate l/min Focus on A Breather plug G/8 - A/F 8 B Indicator port Plug T - A/F 0 C Compensation valve D Oil drain plug G/8 - A/F 8 LMP Fit one differential indicator for individual filter assembly. A B A B D C A C B B D D 89 Low & Medium Pressure filters

114 LMD00-0 Designation & Ordering code Series and size LMD00 LMD0 Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments V FPM Z FPM compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: LMD0 Filtration rating Axx Mxx Pxx B V F A0 N P0 Connections F / SAE 000 psi/m F / SAE 000 psi/unc F / SAE 000 psi/m, In-line connections F / SAE 000 psi/unc, In-line connections LMD00 LMD0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 Maintenance from the bottom of the housing Pxx Customized Filter length 5 6 Element series and size CU00 FILTER ELEMENT Configuration example: CU00 A0 V N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals V Z FPM FPM compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 90

115 LMD00-0 Dimensions LMD00 Length Connections F F F F R M / UNC M / UNC Recommended clearance space for maintenance 9 Low & Medium Pressure filters

116 LMD00-0 Dimensions LMD00 Length 5-6 H [mm] Filter H Execution length [mm] P0 P Connections F F F F R M / UNC M / UNC H - Recommended clearance space for maintenance Low & Medium Pressure filters 9

117 LMD00-0 Dimensions LMD0 Length Connections F F F F R M / UNC M / UNC Recommended clearance space for maintenance 9 Low & Medium Pressure filters

118 LMD00-0 Dimensions LMD0 Length 5-6 H [mm] Filter H Execution length [mm] P0 P Connections F F F F R M / UNC M / UNC H - Recommended clearance space for maintenance Low & Medium Pressure filters 9

119 LMD Low & Medium Pressure filters

120 LMD Designation & Ordering code Series and size LMD Length 5 6 Bypass valve S Without bypass B.5 bar Seals and treatments V Z FPM FPM compatible with fluids HFA-HFB-HFC Connections F / SAE 000 psi/m F / SAE 000 psi/unc F / SAE 000 psi/m, In-line connections F / SAE 000 psi/unc, In-line connections COMPLETE FILTER Configuration example: LMD Filtration rating Axx Mxx Pxx 5 B V F A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard P0 With internal reduced flow rate tube Pxx Customized Element series and size CU00 FILTER ELEMENT Configuration example: CU00 5 A0 V N P0 Element length 5 6 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals V Z FPM FPM compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 96

121 LMD Filter length 5 6 LMD H [mm] 6 9 Dimensions H [mm] Low & Medium Pressure filters

122 LMD00-0 & Order number for spare parts SPARE PARTS LMD 00 5c 5d a 7 b 5b 5a 6 LMD 0 LMD b 5b 5a a 6 a 7 5d 5c 6 7 b 5c 5d 5b 5a Item: Filter series LMD Q.ty: pc. Q.ty: pcs. Q.ty: pc. Q.ty: pc. Q.ty: pc. Q.ty: pcs. (a b) 5 (5a 5d) 6 7 -way ball valve PN 6 One-way valve Seal Kit Threaded Kit ball valve Filter / SAE 000 psi/m / SAE 000 psi/unc fasteners kit with hose fitting See order table LMP00xF... Low & Medium Pressure filters 98

123 LMD00-0 & 99 Low & Medium Pressure filters

124 Low & Medium Pressure filters 00

125 Low & Medium Pressure fi lters LMD 95 series Maximum pressure up to 6 bar - Flow rate up to 00 l/min 0 Low & Medium Pressure filters

126 LMD95 GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 6-5 bar - Flow rate up to 00 l/min Filter housing materials - Head: Anodized Aluminium - Housing: Anodized Aluminium - Manifolds: Welded - Painted black - Bypass valve: Steel - -way ball valve: Steel body - Stainless Steel ball - Check valve: Cast Iron body - AISI 0 leaf Pressure - SAE + DIN Flange - Working pressure:.6 MPa (6 bar) - Test pressure:.5 MPa (5 bar) Seals FPM series V Temperature From -5 C to +0 C Connections - LMD 95: In-line Inlet/Outlet - Same side Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LMD 95 filters are provided for vertical mounting Number of filter elements LMD 95: filter elements CU950- p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMD 95 Weights [kg] DN 80 DN Volumes [dm ] DN 80 DN Hydraulic symbols LMD Low & Medium Pressure filters 0

127 GENERAL INFORMATION LMD95 The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Pressure drop. LMD 95 Filter housings p pressure drop Δp bar DN 80 DN Flow rate l/min 6 LMD 95 Bypass valve pressure drop Δp bar Flow rate l/min Focus on P EXECUTION Execution P0 Internal tube for reduced flow rate is recommended for flow rates lower than 50 I/min. C The use of option P0 makes it easier to fill the housing with the operating fluid. D B B Internal tube for reduced flow rates LMD 95 Fit one differential indicator for individual filter assembly. A B C D Breather plug G/ - A/F 0 Indicator port Plug T - A/F 0 Compensation valve Oil drain plug G/ - A/F 0 0 Low & Medium Pressure filters

128 LMD95 Designation & Ordering code COMPLETE FILTER Series and size Configuration example: LMD95 B V F A0 N P0 LMD95 Length Bypass valve S Without bypass Seals and treatments V FPM B.5 bar Connections F SAE 000 psi/m F SAE 000 psi/unc F SAE 000 psi/m F SAE 000 psi/unc F5 SAE 000 psi/m, In-line connections F6 SAE 000 psi/unc, In-line connections F7 SAE 000 psi/m, In-line connections F8 SAE 000 psi/unc, In-line connections Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Element p N 0 bar P0 P0 Pxx Execution MP Filtri standard With internal reduced flow rate tube Customized Element series and size CU950 FILTER ELEMENT Configuration example: CU950 A0 V N P0 Element length Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Seals V FPM Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters 0

129 LMD95 Dimensions Recommended clearance space for maintenance LMD95 Connections F F F F F5 F6 F7 F8 H [mm] L [mm] L [mm] M [mm] Low & Medium Pressure filters

130 LMD95 Order number for spare parts SPARE PARTS LMD e 5f a b 5b 5a 5c 5f 5d a a Item: Filter series LMD 95 F - F - F5 - F6 / D - D ( SAE / DIN PN6 DN 80) F - F - F7 - F8 / D - D ( SAE / DIN PN6 DN 00) Q.ty: pc. Q.ty: pc. Q.ty: pcs Q.ty: pcs. One-way valve -way ball valve PN 6 SAE 000 psi/m SAE 000 psi/m SAE 000 psi/unc SAE 000 psi/unc Q.ty: pc. Q.ty: pc. (5a 5f) Seal Kit Threaded fasteners kit G / Ball Valve Kit with straight fittings 0050 Item 7: for complete fi lter code and spare parts, see LMP series chapter Quantity: - fi lter spare parts: pcs. - fi lter seal kit: pcs. Filter LMP95xVFxxxNP0 LMP95xVFxxxNP0 Low & Medium Pressure filters 06

131 LMD95 07 Low & Medium Pressure filters

132 Low & Medium Pressure filters 08

133 Low & Medium Pressure filters LDP & LDD series Maximum pressure up to 60 bar - Flow rate up to 0 l/min DIN 550 Filter element according to DIN Low & Medium Pressure filters

134 LDP & LDD GENERAL INFORMATION Filter element according to DIN 550 Technical data Low & Medium Pressure filters Filter housing materials - Head: Aluminium - Bowl: Cataphoretic Painted Steel - Bypass valve: AISI 0 - Nylon Maximum pressure up to 60 bar - Flow rate up to 0 l/min Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 6 MPa (60 bar) - Test pressure: 9 MPa (90 bar) - Burst pressure: MPa (0 bar) - Pulse pressure fatigue test: cycles with pressure from 0 to 6 MPa (60 bar) Temperature From -5 C to +0 C Connections Inlet/Outlet In-Line Bypass valve - Opening pressure.5 bar ±0% - Other opening pressures on request. Note LDP - LDD filters are provided for vertical mounting p element type - Microfibre filter elements - series N: 0 bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LDP - LDD 06 LDP - LDD 05 LDP - LDD 00 Weights [kg] Length Volumes [dm ] Length.6..8 Hydraulic symbols LDP execution S LDP execution B LDD execution S LDD execution B Low & Medium Pressure filters 0

135 GENERAL INFORMATION LDP & LDD Filter element according to DIN 550 The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. 0.9 LDP - Δp Housing 0.9 LDD - Δp Housing Pressure drop Filter housings p pressure drop 0.6 / / 0.6 Δp bar 0. Δp bar Flow rate l/min Flow rate l/min 9 LDD - LDP Bypass valve pressure drop Δp bar Flow rate l/min Low & Medium Pressure filters

136 LDP Designation & Ordering code Filter element according to DIN 550 Series and size LDP Size 06 Element according to DIN T DN60 05 Element according to DIN T DN50 00 Element according to DIN T DN00 Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LDP 05 B A D 6 A0 N P0 Connections A G B G / C G / D NPT E / NPT Connection for differential indicator 6 With plugged connection F G H I / NPT SAE 6-5/6 - UN SAE 0-5/8 - UN SAE - 7/8 - UN Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size DN FILTER ELEMENT Configuration example: DN 05 A0 A N P0 Element size 06 Element according to DIN T DN60 05 Element according to DIN T DN50 00 Element according to DIN T DN00 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

137 Filter element according to DIN 550 Filter size LDP LDP Dimensions H [mm] Connections A-B-C D-E-F-G-H-I R M8 5/6 UNC Drain plug only length Recommended clearance space for maintenance Low & Medium Pressure filters

138 LDD Designation & Ordering code Filter element according to DIN 550 Series and size LDD Size 06 Element according to DIN T DN60 05 Element according to DIN T DN50 00 Element according to DIN T DN00 Bypass valve S Without bypass Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC B.5 bar Connections C G / F / NPT I SAE - 7/8 - UN L / SAE 000 psi/m + G / M / SAE 000 psi/unc + / NPT N / SAE 000 psi/unc + SAE 0-5/8 UN Connection for differential indicator 6 With plugged connection COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LDD 05 B A C 6 A0 N P0 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N 0 bar Execution P0 MP Filtri standard Pxx Customized Element series and size DN FILTER ELEMENT Configuration example: DN 05 A0 A N P0 Element size 06 Element according to DIN T DN60 05 Element according to DIN T DN50 00 Element according to DIN T DN00 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A6 Inorganic microfiber 6 µm P0 Resin impregnated paper 0 µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N 0 bar ACCESSORIES Execution P0 MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9-0 DVA Visual differential indicator DLA Electrical / visual differential indicator 0- DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

139 Filter element according to DIN 550 Filter size LDD LDD Dimensions H [mm] Connections C F - I L M - N R M0 /8 UNC M0 /8 UNC Recommended clearance space for maintenance 5 Low & Medium Pressure filters

140 LDP & LDD Filter element according to DIN 550 SPARE PARTS Order number for spare parts LDP c d a b Item: Filter series LDP Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table TH TV Low & Medium Pressure filters 6

141 SPARE PARTS LDP & LDD Filter element according to DIN 550 LDD Order number for spare parts c d e f g h a b Item: Filter series LDD Q.ty: pc. Q.ty: pc. Q.ty: pc. (a h) Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table TH TV 7 Low & Medium Pressure filters

142 Low & Medium pressure filters Clogging indicators Differential indicators Introduction Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. This is achieved by using filter housings equipped with clogging indicators. These devices trip when the clogging of the filter element causes an increase in pressure drop across the filter element. The indicator is set to alarm before the element becomes fully clogged. MP Filtri can supply differential pressure indicators with a visual, electrical or both signals. Suitable indicator types DIFFERENTIAL INDICATORS Differential indicators are used on the Pressure line to check the efficency of the filter element. They measure the pressure upstream and downstream of the filter element (differential pressure). Standard items are produced with special connection G / size. Also available in Stainless Steel models. OUT OUT OUT OUT IN IN IN IN Quick reference guide Filter series Visual indicator Electrical indicator Electrical / Visual indicator Electronic indicator With bypass valve LMP LMP LMP LDP LMP LMP LMD LDD DVA0xP0 DVM0xP0 DEA0xA50P0 DEM0xAxxP0 DLA0xA5P0 DLA0xA5P0 DLA0xA7P0 DLE0xA50P0 DLE0xF50P0 DTA0xF70P0 Without bypass valve LMP LMP LMP LDP LMP LMP LMD LDD DVA50xP0 DVM50xP0 DEA50xA50P0 DEM50xAxxP0 DLA50xA5P0 DLA50xA5P0 DLA50xA7P0 DLE50xA50P0 DLE50xF50P0 DTA50xF70P0 Low & Medium Pressure filters 8

143 Electrical Differential Indicator Settings bar ±0% 5 bar ±0% 5 DEA*50 Ordering code DE A 0 x A 50 P0 DE A 50 x A 50 P0 A/F 0 Max tightening torque: 65 N m Hydraulic symbol Electrical symbol 5 DIFFERENTIAL INDICATORS Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Dimensions Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 IP69K according to ISO Electrical data - Electrical connection: EN Resistive load: 0. A / 5 Vdc Electrical Differential Indicator Settings bar ±0% 5 bar ±0% DEM*0 A/F 8 Max tightening torque: 65 N m Ordering code DE M 0 x x 0 P0 DE M 50 x x 0 P0 flexible cable: 90 to A 60 Hydraulic symbol Electrical symbol GREEN LAMP RED LAMP Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C 5 Thermal lockout Thermal lockout Thermal GREEN LAMP - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 Electrical data - Electrical connection: AMP Superseal series.5 - Resistive load: 0. A / 5 Vdc - Switching type: Normally open contacts (NC on request) - Thermal lockout: Normally open up to 0 C (option F ) 75 RED LAMP Electrical Differential Indicator Settings bar ±0% 5 bar ±0% 60 DEM*0 Ordering code DE M 0 x x 0 P0 DE M 50 x x 0 P0 75 Hydraulic symbol Electrical symbol Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar C - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids A HFA, HFB, HFC according to ISO 9B - Degree protection: IP66 according to EN 6059 Thermal lockout Thermal lockout Thermal lockout Thermal lockout A/F 8 Max tightening torque: 65 N m Electrical data - Electrical connection: AMP Time junior - Resistive load: 0. A / 5 Vdc - Switching type: Normally open contacts (NC on request) - Thermal lockout: Normally open up to 0 C (option F ) C Thermal lockout 9 Low & Medium Pressure filters

144 DIFFERENTIAL INDICATORS Dimensions 60 Electrical Differential Indicator Settings bar ±0% 5 bar ±0% 75 DEM*0 Thermal lockout Ordering code DE M 0 x x 0 P0 DE M 50 x x 0 P0 A/F 8 Max tightening torque: 65 N m 75 Hydraulic symbol Electrical symbol Thermal lockout Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: C From -5 C to +0 C - Compatibility Thermal with fluids: lockoutmineral oil, Synthetic fluids A HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 B Electrical data - Electrical connection: Deutsch DT-0--P - Resistive load: 0. A / 5 Vdc - Switching type: Normally open contacts (NC on request) - Thermal lockout: Normally open up to 0 C (option F ) 5 75 Electrical Differential Indicator Settings bar ±0% 5 bar ±0% A/F 8 Max tightening torque: 65 N m DEM*5 Thermal lockout Ordering code DE M 0 x x 5 P0 DE M 50 x x 5 P0 flexible cable: 0 to A 5 Hydraulic symbol Electrical symbol C Thermal lockout A B Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 Electrical data - Electrical connection: Deutsch DT-0--P - Resistive load: 0. A / 5 Vdc - Switching type: SPDT contact - Thermal lockout: Normally open up to 0 C (option F ) 50 Electrical/Visual Differential Indicator Settings bar ±0% 5 bar ±0% 5 DLA*5 - DLA*5 Ordering code DL A 0 x A x x P0 DL A 50 x A x x P0 A/F 0 Max tightening torque: 65 N m Hydraulic symbol Electrical symbol GREEN LAMP RED LAMP Materials - Body: Brass - Base: Transparent Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From GREEN-5 C to RED +0 C LAMP LAMP - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP66 according to EN 6059 IP69K according to ISO Electrical data - Electrical connection: EN Type Lamps Vdc 0 Vdc - Resistive load: 0.8 A / Vdc 0. A / 0 Vdc Low & Medium Pressure filters 0

145 Electrical/Visual Differential Indicator 50 Settings bar ±0% 5 bar ±0% DLA*7 Ordering code DL A 0 x A 7 P0 DL A 50 x A 7 P0 A/F 0 Max tightening torque: 65 N m Hydraulic symbol Electrical symbol 5 GREEN LAMP RED LAMP DIFFERENTIAL INDICATORS Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Dimensions Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 IP69K according to ISO 065 Electrical data - Electrical connection: IEC D (M) - Lamps Vdc - Resistive load: 0. A / Vdc Electrical/Visual Differential Indicator 58 Settings bar ±0% 5 bar ±0% 5 GREEN LAMP DLE*A50 RED LAMP Ordering code DL E 0 x A 50 P0 DL E 50 x A 50 P0 59 Hydraulic symbol Electrical symbol 58 Materials - Body: Brass - Base: Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 A/F Max tightening torque: 95 N m Electrical data - Electrical connections: EN Resistive load: 5 A / 50 Vac - Available the connector with lamps 58 Electrical/Visual Differential Indicator Settings bar ±0% 5bar ±0% DLE*F50 Ordering code DL E 0 x F 50 P0 DL E 50 x F 50 P0 58 Hydraulic symbol Electrical symbol Materials - Body: Brass - Thermal Base: lockout Black Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 A/F Max tightening torque: 95 N m Thermal lockout Electrical data - Electrical connections: EN Resistive load: 5 A / 50 Vac - Thermal lockout setting: +0 C Low & Medium Pressure filters

146 DIFFERENTIAL INDICATORS Dimensions Electronic Differential Indicator Settings bar ±0% 5 bar ±0% 7 DTA*70 Ordering code DT A 0 x x 70 P0 DT A 50 x x 70 P0 A/F 0 Max tightening torque: 50 N m 5 Hydraulic symbol 5 Electrical symbol + Vdc 0 ma 75% - N.O. Digital output 00% - N.O. Digital output 0 Vdc Materials - Body: Brass - Internal parts: Brass - Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP67 according to EN 6059 Electrical data - Electrical connection: IEC D (M) - Power supply: Vdc - Analogue output: From to 0 ma - Thermal lockout: 0 C (all output signals stalled up to 0 C) Visual Differential Indicator Settings bar ±0% 5 bar ±0% 9 DVA Ordering code DV A 0 x P0 DV A 50 x P0 Green / Red clogging indicator A/F 8 Max tightening torque: 65 N m Hydraulic symbol Materials - Body: Brass - Internal parts: Brass - Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Reset: Automatic reset - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 Visual Differential Indicator Settings bar ±0% 5 bar ±0% DVM Ordering code DV M 0 x P0 DV M 50 x P0 Red clogging indicator Hydraulic symbol Materials - Body: Brass - Internal parts: Brass - Nylon - Contacts: Silver - Seal: HNBR - FPM Technical data - Reset: Manual reset - Max working pressure: 0 bar - Proof pressure: 60 bar - Burst pressure: 60 bar - Working temperature: From -5 C to +0 C - Compatibility with fluids: Mineral oil, Synthetic fluids HFA, HFB, HFC according to ISO 9 - Degree protection: IP65 according to EN 6059 A/F 0 Max tightening torque: 65 N m Low & Medium Pressure filters

147 Seal HNBR FPM T Indicator plug Ordering code T H T V DIFFERENTIAL INDICATORS Materials - Body: Phosphatized steel - Seal: HNBR / FPM Dimensions A/F 0 Max tightening torque: 50 N m DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATORS Series Configuration example : DE M 0 H F 50 P0 DE Electrical differential indicator Configuration example : DL E 50 V A 7 P0 DL Electrical/Visual differential indicator Configuration example : DT A 0 H F 70 P0 DT Electronic differential indicator DV Visual differential indicator Configuration example : DV M 50 V P0 Type A Standard type M With wired electrical connection E For high power supply DE DL DT A M DV With automatic reset With manual reset Pressure setting 0 bar 50 5 bar Seals H HNBR V FPM Thermostat A F Without With thermostat DEA DEM DLA DLE DT DV Electrical connections 0 Connection AMP Superseal series.5 0 Connection AMP Timer Junior 0 Connection Deutsch DT-0--P 5 Connection Deutsch DT-0--P 50 Connection EN Connection EN , transparent base with lamps Vdc 5 Connection EN , transparent base with lamps 0 Vdc 70 Connection IEC D (M) 7 Connection IEC D (M), black base with lamps Vdc DEA DEM DLA DLE DT DV Option P0 MP Filtri standard Pxx Customized Series T Indicator plug DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATOR PLUG Configuration example T H Seals H HNBR V FPM Low & Medium Pressure filters

148 Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. This is achieved by using filter housings equipped with clogging indicators. These devices trip when the clogging of the filter element causes an increase in pressure drop across the filter element. The indicator is set to alarm before the element becomes fully clogged. MP Filtri can supply indicators of the following designs: - Vacuum switches and gauges - Pressure switches and gauges - Differential pressure indicators These type of devices can be provided with a visual, electrical or both signals. Clogging Indicators 580

149 Clogging Indicators 58 Clogging Indicators

150 Clogging Indicators 58

151 Clogging indicators Clogging indicators 58 Clogging Indicators

STAINLESS STEEL HIGH PRESSURE FILTERS

STAINLESS STEEL HIGH PRESSURE FILTERS STAINLESS STEEL HIGH PRESSURE FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests

More information

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SPIN-ON FILTERS C M Y CM MY CY CMY K

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SPIN-ON FILTERS C M Y CM MY CY CMY K SPIN-ON FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests of a market still to

More information

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing

More information

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada M Y (Not LMP900-901/902-903/950-951/952-953-954) Positioned on the return line to the tank, return filters perform the task of filtering fluid and preventing particles entering the system - externally

More information

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters Return / Suction fi lters Inline LMP series Maximum pressure up to 8 bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min Low & Medium Pressure filters & series Maximum pressure up to 60 bar Flow rate up to 0 l/min DIN 550 09 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE

More information

LMP series

LMP series Low & Medium Pressure fi lters LMP 95-95-95 series Maximum working pressure up to.5 MPa (5 bar) - Flow rate up to 000 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE

More information

HYDRAULIC FILTRATION PRODUCTS

HYDRAULIC FILTRATION PRODUCTS HYDRAULIC FILTRATION PRODUCTS HIGH PRESSURE FILTERS PASSION TO PERFORM A WORLDWIDE LEADER THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt

More information

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

RETURN / SUCTION FILTERS

RETURN / SUCTION FILTERS RETURN / SUCTION FILTERS A WORLDWIDE LEADER THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 9, when Bruno Pasotto decided to attempt to cater for the requests of a market still

More information

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters igh Pressure fi lters FP series Maximum pressure up to bar Flow rate up to 7 l/min igh Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters Return / Suction fi lters mounted MRSX series Maximum pressure up to bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZG The correct filter sizing have to be based on the variable pressure

More information

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min NEW High Pressure filters FMM 50 series Maximum pressure up to 0 bar - Flow rate up to 50 l/min PASSION TO PERFORM FILTER SIZING THE CORRECT FILTER SIZING HAVE TO BE BASED ON THE TOTAL PRESSURE DROP DEPENDING

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold

More information

Series RFLD Duplex In-Line Filter

Series RFLD Duplex In-Line Filter APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.

More information

[You may download this article at: https://fluidsys.org/downloads/ ]

[You may download this article at: https://fluidsys.org/downloads/ ] Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition:

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition: Filter elements for installation in Pall filter housings Type 16. filter elements RE 51464 Edition: 2014-04 Frame sizes: 6200 to 9801 Collapse pressure rating: 10 to 210 bar [145 to 3045 psi] Temperature

More information

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Suction Filters ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream

More information

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic

More information

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition: Spin-on elements Type 80, 81 and 82 RE 51478 Edition: 2015-06 Sizes according to according to Bosch Rexroth standard: 30 to 130 Pressure differential resistance up to 5 bar [72.5 psi] Filter rating: 1

More information

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Suction Filters ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp.

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

Filter elements, two-stage for installation in wind turbines with Hydac filter housings. Type 65. Filter elements. Contents.

Filter elements, two-stage for installation in wind turbines with Hydac filter housings. Type 65. Filter elements. Contents. Filter elements, two-stage for installation in wind turbines with Hydac filter housings Type 65. Filter elements RE 51461 Edition: 2017-02 Replaces: 11.13 Exchangeable with filter element 1300 R... BN...HC/-B4-KE50

More information

Filter elements for microfiltration. Type 46. CELLUDISC filter elements. Features. Contents. RE Edition:

Filter elements for microfiltration. Type 46. CELLUDISC filter elements. Features. Contents. RE Edition: Filter elements for microfiltration Type 46. CELLUDISC filter elements RE 51470 Edition: 2014-08 Size: 10" Maximum pressure differential: 5 bar [73 psi] Filter rating: 2 and 10 μm Operating temperature:

More information

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min High Pressure Filters Worldline HD 79 HD 99 In-line mounting Operating pressure up to bar Nominal flow rate up to. l/min Description Application In the high pressure circuits of hydraulic systems. Performance

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RC MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2002) Max working:

More information

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to bar / 97 psi Nominal flow rate up to. l/min / 4. gpm Description Application In the high pressure circuits of hydraulic

More information

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Filtering elements differential collapsing pressure tested in compliance with ISO 2941: DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost in its mind,

More information

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min INLIN FILTR Maximum working pressure 0 bar Flow rate to 00 l/min R.F. Filter Symbol without bypass Filter Symbol with Reverse Flow R.F. Filter Symbol with bypass Filter Symbol with bypass & Reverse Flow

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RB MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2) Max working: 0 kpa

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Series RFL In-Line Filter

Series RFL In-Line Filter APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction

More information

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min Suction Filters ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min Description pplication To be installed in the suction line of the pumps of hydraulic systems resp. upstream

More information

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for

More information

D e s c r i p t i o n

D e s c r i p t i o n e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into

More information

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm Off-line Filter Unit FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm Description Application In the by-pass flow of hydraulic and lubrication systems. Performance

More information

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements We produce fluid power solutions Fluid Management Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements Products with these icons are specially made for: Industrial

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min Pressure Filters D 1 D 3 D 33 In-line mounting Operating pressure up to 3 bar Nominal flow rate up to 3 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e Return-Suction Filters E 68 E 88 In-line mounting Connection up to G¾ Nominal flow rate up to l/min.8-e Description Application For operation in units with hydrostatic drives, when the return flow is under

More information

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C COMPONENTS MATERIALS Head: Aluminium alloy Spinon cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile (FKM on request fluoroelastomer) Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters series Maximum pressure up to bar - Flow rate up to 15 l/min 193 Return fi lters GENERAL INFORMATION Technical data Return filter Maximum pressure up to bar - Flow rate up to 15 l/min Filter

More information

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min Return-Suction Filters E 68 E 88 In-line mounting Connection up to G¾ Nominal flow rate up to l/min Description Application For operation in units with hydrostatic drives, when the return flow is under

More information

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm Off-line Filters FN 6 FN In-line mounting Operating pressure up to bar / 74 psi Nominal flow rate up to 65 l/min / 7 gpm Description Application Return-flow filter or off-line filter in hydraulic and lubrication

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction................................... 1-3 HF65 Series................................. 1-9 HF66 Series................................ 1-15 HF67 Series................................

More information

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e High Pressure Filters HD HD Flangeable Operating pressure up to bar Nominal flow rate up to l/min.3-e Description Application In the high pressure circuits of hydraulic systems. Performance features Protection

More information

In line high pressure filters. HF 725 series

In line high pressure filters. HF 725 series In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40. High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to 97 psi Nominal flow rate up to 64. gpm 4.9-us Description Application In the high pressure circuits of hydraulic

More information

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e Off-line Filters FNS 060 With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min 80.20-2e Description Application In the high pressure circuits of hydraulic and lubricating

More information

In line high pressure filters. HF 735 series

In line high pressure filters. HF 735 series In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us Return-Suction Filters E 58 E 98 E 48 Tank top mounting Connection up to - SAE Nominal flow rate up to gpm.9-7us Description Application For operation in units with hydrostatic drives, when the return

More information

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm Off-line Filter Units FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm Description Application In the by-pass flow of hydraulic and lubrication systems.

More information

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS 1 OIL FILTER DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction.... 1- HF65 Series.... 1-9 HF66 Series.... 1-15 HF67 Series.... 1-21 HF68 Series.... 1-1 Dual Spin-On Assembly.... 1-5 Introduction Hydraulic Filtration Systems Cummins

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to

More information

MPF filters within this range are suitable for flow rates up to 750 l/min.

MPF filters within this range are suitable for flow rates up to 750 l/min. D e s c r i p t i o n MPF series filters are designed for return lines, and are installed semi-immersed in a reservoir. Continued Research & Development on both the filter bodies and the filter elements

More information

Ultipleat SRT Filters

Ultipleat SRT Filters Lenntech info@lenntech.com www.lenntech.com Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 Ultipleat SRT Filters Stress Resistant Technology The Ultimate in Filter Design Ultipleat SRT Filters Pall s Ultipleat

More information

Components and Systems for the Automotive Industry

Components and Systems for the Automotive Industry Components and Systems for the Automotive Industry E 10.136.0/03.12 HYDAC Germany HYDAC USA HYDAC China HYDAC Korea The Professional Partner for the Automotive Industry With over 6,000 staff worldwide,

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block

More information

Line filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550 Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the

More information

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the

More information

Off-line Oil Filter Module Pi 8400

Off-line Oil Filter Module Pi 8400 Off-line Oil Filter Module Pi 8400 Volume flow l/min 1. Features Compact, ready-to connect oil filter module for modern hydraulic and lubrication systems Low noise internal gear pump Minimum loss of performance

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition: Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D RE 51476 Edition: 2015-06 Nominal sizes: 30 to 80D Connection up to G1; SAE 10 56558_d Features Spin-on filters are used in hydraulic

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:

More information

FNK 050 FNK 100 Operating pressure up to 10 bar Nominal flow rate up to 125 l/min Cooling capacity up to 45 kw

FNK 050 FNK 100 Operating pressure up to 10 bar Nominal flow rate up to 125 l/min Cooling capacity up to 45 kw Filter Cooling Units FNK 050 FNK 100 Operating pressure up to 10 bar Nominal flow rate up to 125 l/min Cooling capacity up to 45 kw Description Application Return-flow or off-line filter in hydraulic systems

More information

SRX R. Remediation Pumps. Simply Reliable

SRX R. Remediation Pumps. Simply Reliable SRX R Remediation Pumps Simply Reliable The SRX pump is based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

Automatic Back-Flushing Filter AutoFilt RF9.

Automatic Back-Flushing Filter AutoFilt RF9. Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization

More information

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,

More information

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart Models 5MFP & 10MFP with Modufl ow and Intelli-Cart 174 Applications Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid

More information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style

More information

Flow rates to 500 l/min

Flow rates to 500 l/min FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:

More information

Introduction to Hydraulic Filtration

Introduction to Hydraulic Filtration sales@nationalfiltersinc.com * www.nationalfilters.com 360 Industrial Parkway * Harbor Beach, MI USA * 48441 TF: 1-888-797-3275 * Tel: 989-479-3273 * Fax: 989-479-3251 1 What is Fluid Power? Fluid power

More information

Block mounting filter, for vertical flange-mounting

Block mounting filter, for vertical flange-mounting Block mounting filter, for vertical flange-mounting RE 51417/12.1 Replaces: 7.1 1/18 Type 45PBFN4 to 1; 45PBF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 45 bar [653

More information

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi) HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:

More information

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM. MATERIALS Head: Aluminium alloy Bowl: Steel Bypass valve: Steel Seals: NBR Nitrile (FKM - on request fluoroelastomer) Indicator housing: Brass PRESSURE Max working: 5 MPa ( bar) Collapse, differential

More information

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar / Series Max 26 l/min - 21 bar A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

Number Title Year Organization Page

Number Title Year Organization Page Id Number Title Year Organization Page 365528 B93.1 Dimension Identification Code for Fluid Power Cylinders; Appendices I and II (NFP(A) T3.6.2-1964) R(1994) 365529 B93.2 Fluid Power Systems and Products

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01. Spin-on filter according to Bosch Rexroth standard Type 7 SL 30 260; 7 SLS 90 260 RE 51426 Edition: 2015-03 Replaces: 01.10 Nominal sizes: 7 SL 30 260; 7 SLS 90 260 Nominal pressure 7 bar [101 psi] Connection

More information

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting Block mounting filter, for lateral flange-mounting RE 51418/12.1 Replaces: 1.1 1/18 Type 245PSFN4 to 4; 245PSF13, 15 Size according to DIN 2455: 4 to 4 Additional sizes: 13, 15 Nominal pressure 25 bar

More information

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550 Inline filter with filter element according to DIN 24550 RE 51422/07.11 Replaces: 12.10 1/18 Type 350LEN0040 to 1000; 350LE0130, 0150 Size according to DIN 24550: 0040 to 1000 Additional sizes: 0130, 0150

More information

FILTER ELEMENTS. Overview of Elements PN# / / FIL

FILTER ELEMENTS. Overview of Elements PN# / / FIL Overview of Elements C1 Overview of Elements Optimicron Elements ON - code designation Glass fiber, multi-layered with support Collapse rating - 29 psid (2 bar) 1, 3, 5, 1, 15, 2 micron Filtration Rating

More information

Filter elements for the installation into Hydac filter housings. Type 9. and 10. filter elements. Features. Contents

Filter elements for the installation into Hydac filter housings. Type 9. and 10. filter elements. Features. Contents Filter elements for the installation into Hydac filter housings Type 9. and 10. filter elements RE 51457 Edition: 2017-02 Replaces: 06.15 Installation in return flow filters (R) Installation in inline

More information

FILTER MEDIA. Mainly used filter material: INTERPOR FLEECE VG GLASS FIBRE PAPER MATTING P STAINLESS STEEL MESH G

FILTER MEDIA. Mainly used filter material: INTERPOR FLEECE VG GLASS FIBRE PAPER MATTING P STAINLESS STEEL MESH G The name INTERNORMEN stands for competence and more than four decades of experience in developing products in the field of filter technology, including modern software, measuring equipment and analysis

More information

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550 Inline filter with filter element according to DIN 24550 RE 51421/07.11 Replaces: 12.10 1/16 Type 245LEN0040 to 400; 245LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130, 0150

More information

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting Block mounting filter, for lateral flange-mounting RE 51419/2.1 1/18 Type 35PSFN4 to 1; 35PSF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 35 bar [579 psi] Port up

More information

HYDAC LowViscosity Housings: Highest diesel quality on the whole transport route

HYDAC LowViscosity Housings: Highest diesel quality on the whole transport route LowViscosity Housings: Highest diesel quality on the whole transport route Diesel LowVisco: a bundle of Play safe with diesel: any time, any place Stricter emissions directives and increased power output

More information

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04 Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01. Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4

More information