3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

Size: px
Start display at page:

Download "3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses"

Transcription

1 .5 Limiting Fuses (N)CLPT Fuses Contents escription Selection Product Selection etails Page V14-T-4 V14-T-4 V14-T-48 Product escription aton CLPT (indicating) and NCLPT (non-indicating) fuses are applied wherever it is necessary to limit the shortcircuit currents on control transformer and potential transformer circuits in high capacity systems in industrial installations and commercial buildings. ratings from 1/2 to 10 are available at 2.4 kv to 4.5 kv. Features CLPT and NCLPT type current limiting fuses offer a number of desirable advantages. Consider the following during the selection process: Quiet Safe Operation: These fuses are designed for silent operation and elimination of flame discharges when the fuse operates Identification of Blown Fuse: These fuses are available in indicating and non-indicating versions. Indicators protrude from indicating type fuses providing a visual indication of a blown fuse Space conomy: Because the fuse is designed to eliminate flame and gas discharges, no exhaust control devices, flame boxes, vents or reinforcing are required Complete Protection Provided: limiting fuses provide positive interruption even on low fault currents. The fuse limits the magnitude of electromechanical stresses in the apparatus to be protected s: isconnect and non-disconnect mountings are available for most types of fuses from 5 kv through 15 kv. Live parts are available for 2 kv and 4.5 kv fuses imensions: Various fuse sizes are available for a wide range of applications Construction CLPT type current limiting fuses are basically constructed in a similar fashion to other aton current limiting fuses. s and Selection When a decision has been made to use current limiting fuses, the minimum amount of information required to make the proper selection is: Voltage rating rating Interrupting rating method Non-disconnect mounting isconnect mounting Live parts only No required mounting Refer to tables on Pages V14-T-4 to V14-T-49 for assistance in selecting the correct fuse catalog number. These types of fuses are used in conjunction with potential and control power transformers. There are specific rules governing the selection of the required fuse continuous rating. The current limiting fuse application notes earlier in this publication offer additional information about this type of application. When selecting the appropriate fuse for a new installation, keep in mind that one fuse unit and one compatible mounting may be required for each phase. V14-T-42

2 Limiting Fuses.5 Selection CLPT Fuse Units CLPT Product Selection CLPT Type Maximum kv 2 = 2.75 kv 5 = 5.5 kv 8 = 8. kv 15 = 15.5 kv 25 = 25.8 kv 8 = 8 kv Maximum kv 2 = 2.75 kv 5 = 5.5 kv 8 = 8. kv 15 = 15.5 kv 25 = 25.8 kv 8 = 8 kv Type CLPT Type CLPT NCLPT 15 CLPT A Insulator G = Glass polyester P = Porcelain Ampere CLPT - P NM - A imensions A = Shorter length B = Longer length Hardware F = isconnect end fittings L = isconnect live parts M = isconnect mounting NL = Non-disconnect live parts NM = Non-disconnect mounting CLPT Type Limiting Fuses kv Maximum (2.4 kv Nominal) Performance Curves Interrupting iameter Center Length Approximate (Amperes) rms (ka Sym.) Approximate imensions in Inches (mm) Shipping Weight Lbs (kg) Minimum Melting Time Total Clearing Time imensions A = Shorter length B = Longer length Peak Let- Through (20.6) 4.50 (114.) 0.25 (0.11) TC TC TC NCLPT (20.6) 4.50 (114.) 0.25 (0.11) TC TC TC NCLPT (20.6) 4.50 (114.) 0.25 (0.11) TC TC TC NCLPT (20.6) 4.50 (114.) 0.25 (0.11) TC TC TC NCLPT (20.6) 4.50 (114.) 0.25 (0.11) TC TC TC NCLPT-5 V14-T-4

3 .5 Limiting Fuses Non- CLPT Type Limiting Fuses 5.5 kv Maximum (4.8 kv Nominal) Performance Curves Interrupting iameter Center Length Approximate Shipping Minimum (Amperes) rms (ka Sym.) Approximate imensions in Inches (mm) Weight Lbs (kg) Melting Time CLPT Type s and Hardware 5.5 kv Maximum (4.8 kv Nominal) Notes Refers only to 5CLPT and 5NCLPT-A fuses only. See Page V14-T-8 for diagram of typical mounting. nd fittings supplied only when required. Total Clearing Time Peak Let- Through Non (20.6) 5.6 (14.0) 0.25 (0.11) TC TC TC NCLPT (20.6) 5.6 (14.0) 0.25 (0.11) TC TC TC NCLPT (20.6) 5.6 (14.0) 0.25 (0.11) TC TC TC NCLPT (20.6) 5.6 (14.0) 0.25 (0.11) TC TC TC NCLPT (20.6) 5.6 (14.0) 0.25 (0.11) TC TC TC NCLPT (20.6) 5.6 (14.0) 0.25 (0.11) TC TC TC NCLPT (25.4) 5.6 (14.0) 0.25 (0.11) TC TC TC B487H (25.4) 5.6 (14.0) 0.25 (0.11) TC TC TC B487H (25.4) 5.6 (14.0) 0.25 (0.11) TC TC TC B487H (25.4) 5.6 (14.0) 0.25 (0.11) TC TC TC B487H (25.4) 5.6 (14.0) 0.25 (0.11) TC TC TC B487H (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC TC NCLPT-.5-A (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC TC NCLPT-1-A (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC TC NCLPT-2-A (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC TC NCLPT--A (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC TC NCLPT-5-A (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC TC NCLPT-10-A (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.2 (0.54) TC TC56506 TC CLPT-10 Ampere Fuse Type Voltage BIL (kv) (Including, nd Fittings) Porcelain Insulator Glass-Polyester Insulator (Including nd Fittings) nd Fittings (isconnect Only) Non-disconnect 60 5CLPT-PNM-A 5CLPT-GNM-A CLPT-NL isconnect 60 5CLPT-PM-A 5CLPT-GM-A CLPT-L CLPT-F 10 Non-disconnect 60 5CLPT-PNM-B 5CLPT-GNM-B CLPT-NL isconnect 60 5CLPT-PM-B 5CLPT-GM-B CLPT-L CLPT-F V14-T-44

4 Limiting Fuses.5 Non- CLPT Type Limiting Fuses 8. kv Maximum (7.2 kv Nominal) Performance Curves Interrupting iameter Center Length Approximate Shipping Minimum (Amperes) rms (ka Sym.) Approximate imensions in Inches (mm) Weight Lbs (kg) Melting Time CLPT Type s and Hardware 8. kv Maximum (7.2 kv Nominal) Notes Refers only to 8CLPT and 8NCLPT-A or -B fuses only. See Page V14-T-8 for diagram of typical mounting. nd fittings supplied only when required. Total Clearing Time Peak Let- Through Non (20.6) 8.00 (20.2) 0.25 (0.11) TC TC TC NCLPT (20.6) 8.00 (20.2) 0.25 (0.11) TC TC TC NCLPT (27.9) 5.00 (127.0) 0.5 (0.2) TC TC TC NCLPT (27.9) 5.00 (127.0) 0.5 (0.2) TC TC TC NCLPT (27.9) 5.00 (127.0) 0.5 (0.2) TC TC TC NCLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.5 (0.70) TC TC TC NCLPT-.5-A (40.6) 8.10 (205.7) 9.50 (241.) 1.5 (0.70) TC TC TC NCLPT-1-A (40.6) 8.10 (205.7) 9.50 (241.) 1.5 (0.70) TC TC TC NCLPT-2-A (40.6) 8.10 (205.7) 9.50 (241.) 1.5 (0.70) TC TC TC NCLPT--B (40.6) (292.1) (27.7) 1.6 (0.7) TC TC TC NCLPT-5-B (40.6) (292.1) (27.7) 1.6 (0.7) TC TC TC NCLPT-10-B (40.6) 8.10 (205.7) 9.50 (241.) 1.5 (0.70) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.6 (0.7) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.6 (0.7) TC TC56506 TC CLPT (40.6) 8.10 (205.7) 9.50 (241.) 1.6 (0.7) TC TC56506 TC CLPT-10 Ampere Fuse Type Voltage BIL (kv) (Including, nd Fittings) Porcelain Insulator Glass-Polyester Insulator (Including nd Fittings) nd Fittings (isconnect Only) Non-disconnect 75 8CLPT-PNM-A 8CLPT-GNM-A CLPT-NL isconnect 75 8CLPT-PM-A 8CLPT-GM-A CLPT-L CLPT-F 10 Non-disconnect 75 8CLPT-PNM-B 8CLPT-GNM-B CLPT-NL isconnect 75 8CLPT-PM-B 8CLPT-GM-B CLPT-L CLPT-F V14-T-45

5 .5 Limiting Fuses Non- CLPT Type Limiting Fuses 15.5 kv Maximum (7.2 kv Nominal) Performance Curves Interrupting iameter Center Length Approximate Shipping Minimum (Amperes) rms (ka Sym.) Approximate imensions in Inches (mm) Weight Lbs (kg) Melting Time CLPT Type s and Hardware 15.5 kv Maximum (14.4 kv Nominal) Notes See Page V14-T-8 for diagram of typical mounting. nd fittings supplied only when required. Total Clearing Time Peak Let- Through Non (40.6) (292.1) (27.7) 1.6 (0.7) TC TC TC NCLPT (40.6) (292.1) (27.7) 1.6 (0.7) TC TC TC NCLPT (40.6) (292.1) (27.7) 1.6 (0.7) TC TC TC NCLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC TC NCLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC TC NCLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC TC NCLPT (40.6) (292.1) (27.7) 1.6 (0.7) TC TC56506 TC CLPT (40.6) (292.1) (27.7) 1.6 (0.7) TC TC56506 TC CLPT (40.6) (292.1) (27.7) 1.6 (0.7) TC TC56506 TC CLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC56506 TC CLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC56506 TC CLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC56506 TC CLPT-10 Ampere Fuse Type Voltage BIL (kv) (Including, nd Fittings) Porcelain Insulator Glass-Polyester Insulator (Including nd Fittings) nd Fittings (isconnect Only) Non-disconnect 95 15CLPT-PNM-A 15CLPT-GNM-A CLPT-NL isconnect 95 15CLPT-PM-A 15CLPT-GM-A CLPT-L CLPT-F 10 Non-disconnect 95 15CLPT-PNM-B 15CLPT-GNM-B CLPT-NL CLPT-F isconnect 95 15CLPT-PM-B 15CLPT-GM-B CLPT-L V14-T-46

6 Limiting Fuses.5 CLPT Type Limiting Fuses 25.5 kv Maximum (2.0 kv Nominal) Interrupting Approximate Performance Curves iameter Center Length Shipping Minimum Total (Amperes) rms (ka Sym.) Approximate imensions in Inches (mm) Weight Lbs (kg) Melting Time Clearing Time CLPT Type s and Hardware 25.5 kv Maximum (2.0 kv Nominal) nd Fittings (Including, nd Fittings) (Including nd Fittings) (isconnect Only) Ampere Fuse Voltage Porcelain Insulator Glass-Polyester Insulator Type BIL (kv) CLPT Type s and Hardware 8.0 kv Maximum (4.5 kv Nominal) nd Fittings (Including, nd Fittings) (Including nd Fittings) (isconnect Only) Ampere Fuse Voltage Porcelain Insulator Glass-Polyester Insulator Type BIL (kv) Notes See Page V14-T-8 for diagram of typical mounting. nd fittings supplied only when required. Peak Let-Through (40.6) (408.9) (447.0) 2 (0.91) TC TC56508 TC CLPT (40.6) (408.9) (447.0) 2 (0.91) TC TC56508 TC CLPT Non-disconnect CLPT-PNM-A 25CLPT-NL isconnect CLPT-PM-A 25CLPT-L CLPT-F CLPT Type Limiting Fuses 8.0 kv Maximum (4.5 kv Nominal) Interrupting Approximate Performance Curves iameter Center Length Shipping Minimum Total (Amperes) rms (ka Sym.) Approximate imensions in Inches (mm) Weight Lbs (kg) Melting Time Clearing Time Peak Let-Through (40.6) (44.) (472.4) 2 (0.91) TC TC56508 TC CLPT isconnect Not applicable Not applicable 25CLPT-NL CLPT-F Non-disconnect Not applicable Not applicable 25CLPT-L V14-T-47

7 .5 Limiting Fuses etails Approximate imensions in Inches (mm) CLPT and NCLPT Type isconnect s A B A C B Overall Length C Hole Inset Contact Height F Overall Height G 5CLPT-GM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 4.50 (114.) 9.56 (242.8) 60 5CLPT-PM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 4.50 (114.) 9.56 (242.8) 60 8CLPT-GM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 75 8CLPT-GM-B 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 75 8CLPT-PM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 75 8CLPT-PM-B (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 75 15CLPT-GM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 95 15CLPT-PM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 95 15CLPT-GM-B (44.5) 6.00 (152.4) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 95 15CLPT-PM-B (44.5) 6.00 (152.4) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) (06.) 95 15CLPY-HPM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 8.50 (215.9) 1.56 (44.4) CLPT-HPM-B (44.5) 6.00 (152.4) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) 8.50 (215.9) 1.56 (44.4) CLPT-PNM-A (485.6) 7.00 (177.8) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) (04.8) (4.) 150 G F BIL V14-T-48

8 Limiting Fuses.5 Approximate imensions in Inches (mm) CLPT and NCLPT Type Non-isconnect s A B A C B Overall Length C Hole Inset Contact Height F Overall Height G 5CLPT-GNM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 4.50 (114.) 6.94 (176.2) 60 5CLPT-PNM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 4.50 (114.) 6.94 (176.2) 60 8CLPT-GNM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 75 8CLPT-PNM-A 9.7 (28.0) 6.00 (152.4) 18.6 (47.2) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 75 8CLPT-GNM-B (2.8) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 75 8CLPT-PNM-B (2.8) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 75 15CLPT-GNM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 95 15CLPT-PNM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 95 15CLPT-HPNM-A (2.6) 6.00 (152.4) (558.8) 0.75 (19.0) 1.75 (44.4) 8.50 (215.9) (277.9) CLPT-GNM-B (44.5) 6.00 (152.4) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 95 15CLPT-PNM-B (44.5) 6.00 (152.4) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) 7.00 (177.8) 9.44 (29.8) 95 15CLPT-HPNM-B (44.5) 6.00 (152.4) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) 8.50 (215.9) (277.9) CLPT-PNM-A (485.6) 7.00 (177.8) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) (04.8) 14.4 (67.0) 150 8CLPT-PNM-A (485.6) 7.00 (177.8) 26.6 (676.4) 0.75 (19.0) 1.75 (44.4) (04.8) 14.4 (67.0) 150 G F BIL V14-T-49

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses .6 Limiting Fuses Motor Start Fuses Product Description Eaton s CLS current limiting fuses are used in conjunction with medium voltage motor starters to provide shortcircuit protection for individual motor

More information

PT Medium voltage fuses for potential and small power transformers

PT Medium voltage fuses for potential and small power transformers Technical Data 6002 BUSSMANN Supersedes December 2017 SERIES PT Medium voltage fuses for potential and Description: Bussmann series Indicating and nonindicating E-Rated, current-limiting, medium voltage

More information

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352 8.3kV E-Rated Description: E-Rated, current-limiting, medium voltage fuses for feeder circuit, switchgear and transformer protection. Supersedes pril 2015 USSMNN SERIES Medium voltage fuses for feeder

More information

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection Technical ata 6001 Supersedes September 2017 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses

More information

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection Technical ata 6001 Supersedes ecember 2015 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SRIS -RATD / MDIUM VOLTAG FUSS 5kV AND 15kV CLIP-LOCK MOUNTD FUSS Amp-trap -rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as well as

More information

E-RATED/MEDIUM VOLTAGE FUSES

E-RATED/MEDIUM VOLTAGE FUSES SRIS -RATD/MDIUM VOLTAG FUSS 5kV, 8kV and 15.5kV Ferrule mounted fuses Amp-trap -rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced clips.

More information

RBA Catalog Numbers and Information

RBA Catalog Numbers and Information 50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.

More information

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses) .7 Expulsion Fuses RBA Fuses Product Description BA Fuses Westinghouse Electric Company introduced the BA range of DE-ION boric acid refillable fuses in the 1930s, and BA refill units have been in continuous

More information

K-Limiter high ampere Companion II fuse

K-Limiter high ampere Companion II fuse Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently

More information

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc. DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw

More information

FX Full-Range Current-Limiting Fuse

FX Full-Range Current-Limiting Fuse Hi-Tech FX Full-Range Current-Limiting Fuses Trans-Guard FX Full-Range Current-Limiting Fuse Patented damage sensor significantly reduces the risk of fuse failure should the fuse be subjected to an element-damaging

More information

Mica Element Support. Compacted Quartz Sand. Length B

Mica Element Support. Compacted Quartz Sand. Length B Construction A Tin-Plated Brass Caps Dimensional Information for Trans-Guard s NOMINAL 5.5 Resin-Rich Filament Wound Glass/Epoxy Body 3 75 80 200 3 50 5 80 5 125 3 50 5 5 100 23.0 50 Low Current Interruption

More information

Medium Voltage Fuses

Medium Voltage Fuses 2,400-38,000 VAC General Information Current-limiting E and rated fuses are equipped with a mechanical indicator or striker pin that protrudes through the fuse cap upon operation of the fuse. This provides

More information

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION Fusing Equipment Tandem ELF Current-Limiting Dropout Fuse Electrical pparatus 240-67 GENERL The Cooper Power Systems Tandem ELF current-limiting fuse is designed for transformer protection. The Tandem

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED A240R/A480R/A072F/A072B MED. VOTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of

More information

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses) .7 Expulsion Fuses RBA Fuses Product Description BA Fuses Westinghouse Electric Company introduced the BA range of DE-ION boric acid refillable fuses in the 1930s, and BA refill units have been in continuous

More information

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA 5670-100 Technical Guide 15 kv, 23 kv, & 35 kv General Description The Protective link is an oil immersed, expulsion type, fuse

More information

PROTECTION AND CONTROL

PROTECTION AND CONTROL B C Table 1 DIMENSIONAL Information for Trans-Guard OS Fuses Fuse Voltage Rating (kv) 1/4-20 threaded hole 1/2 deep (both ends) Current Rating (Amps) Fuse Catalog Number 35 HTDS232035 Overall Diameter

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED A240R/A480R/A072F/A072B MED. VOTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com DE-ION CURRENT-LIMITING POWER FUSE-TYPE BAL prevents short circuit s from reaching their maximum value and thereby provides greater protective capacity for both the connected apparatus and the feeder system.

More information

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products Hi-Tech SX Full-Range Current-Limiting Fuses Provides both overload and fault current protection for distribution equipment in a single fuse body. Trans-Guard SX Full-Range Current-Limiting Fuse As a full-range

More information

Product Selection Guide

Product Selection Guide Oil-Submersible Backup Fuses Full-Range CL Fuses External Backup Fuses Molded Fuse Products Product Selection Guide Introduction Electric distribution systems demand high levels of reliability, and flexibility

More information

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

OVERALL LENGTH (B)  ( mm)  ( mm)  ( mm)  ( mm) 1 4-20 threaded hole 1 2" deep (both ends) Dimensional Information NOMINAL CURRENT CAT. NO. 40 HTSS232040 50 HTSS232050 65 HTSS232065 80 HTSS232080 100 HTSS232100 125 HTSS232125 150 HTSS232150 165 HTSS232165

More information

X-Limiter full-range current-limiting fuse

X-Limiter full-range current-limiting fuse Fusing Equipment Catalog Data CA132050EN Supersedes 240-56 June 2012 COOPER POWER SERIES X-Limiter full-range current-limiting fuse General Eaton's Cooper Power series X-Limiter full-range current-limiting

More information

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories ,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

WLI Medium Voltage Switchgear Renewal Parts

WLI Medium Voltage Switchgear Renewal Parts Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

Medium voltage fuses Medium voltage fuses

Medium voltage fuses Medium voltage fuses European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A

More information

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A

More information

NX indoor current-limiting fuses

NX indoor current-limiting fuses Fusing Equipment Catalog Data CA132049EN Supersedes 240-60 September 2009 COOPER POWER SERIES NX indoor current-limiting fuses General Eaton provides overload protection for all indoor and underground

More information

Elastimold & Hi-Tech Fuse Products

Elastimold & Hi-Tech Fuse Products In this section... Elastimold & Hi-Tech Fuse Products Elastimold & Hi-Tech Fuse Products Overview...H-62 Elastimold Fused Loadbreak Elbows (FLE)... H-63 H-67 Elastimold Molded Current-Limiting Fuses (MCLF)...

More information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

Low Voltage Fuses AFaC and BaC types

Low Voltage Fuses AFaC and BaC types Fa and a types Fa and a type currentlimiting fuses 600V /, 3 400 mps escription The Fa and a type have an excellent current-limiting performance with an interrupting capacity as high as 100k at 600V /.

More information

SIEMENS. Current-Limiting Fuses. DESCRIPTION ceo '1 I. 2.4 and 4.8 Kv for Motor Starting Application. Type FM. Page 1 EFFECTIVE FEB..

SIEMENS. Current-Limiting Fuses. DESCRIPTION ceo '1 I. 2.4 and 4.8 Kv for Motor Starting Application. Type FM. Page 1 EFFECTIVE FEB.. j SEMENS DESCRPTON CurrentLimiting Fuses 2.4 and 4.8 Kv for Motor Starting Application The fuse (Fig. ) is a totallyenclosed currentlimiting fuse, designed for motorstarting applications. t is available

More information

Limitor -G General Purpose Fuses

Limitor -G General Purpose Fuses Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear

More information

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

Molded Current-Limiting Fuse

Molded Current-Limiting Fuse Molded Current-Limiting provide fullrange fault current protection using specially designed fuse elements, rated through 23kV line to ground and 50kA interrupting current. Construction is modular with

More information

Edison modular fuse, vault application products

Edison modular fuse, vault application products Fusing Equipment Catalog Data CA132025EN Supersedes 240-92 October 2008 Edison modular fuse, vault application products COOPER POWER SERIES Description Eaton s Cooper Power series Edison modular fuses

More information

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) S&C Fault Tamer Fuse Limiter Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

T HREE-SHOT TYPE MZR F USE CUTOUT

T HREE-SHOT TYPE MZR F USE CUTOUT T HREE-SHOT TYPE MZR F USE CUTOUT Page 1 of 7 D ESCRIPTION It is known that about 90% of the defects that occur in an air distribution system, are of a transient origin, i.e., are transient faults which

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Fuse/Var Technical Data

Fuse/Var Technical Data Fuse/Var Technical Data 38-852 CAPACITOR FUSES Selection Guide Interrupting Type ABB Voltage Rated Capability Discharge (Combination) Application See Type Rating Current Iind Icap Capability (Current Limiting)

More information

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy. Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings

More information

EE 741 Over-voltage and Overcurrent. Spring 2014

EE 741 Over-voltage and Overcurrent. Spring 2014 EE 741 Over-voltage and Overcurrent Protection Spring 2014 Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with

More information

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C Page:1 of 9 CERTIFIED TEST REPORT Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C37.41-2008 REV. 00 August 11, 2014 Original Report Date: August 11, 2014 Eaton s Cooper Power Systems

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

T YPE MZ DISTRIBUTION S TANDARD CUTOUT T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal

More information

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up

More information

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION Fusing Equipment ELSG Full Range Current-Limiting Fuse Electrical pparatus 240-82 Contents General......................1 Installation...................1 Production Tests..............1 Electrical Characteristics.......3

More information

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34. S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast). FUSE CATALOG 2 Table 1.-Elemsa code and characteristics of Type K fuse links (Fast). TYPE DESCRIPTION CAT PAGE 15K-1 UNIVERSAL TYPE FUSE LINK 2066A1 38K-1 UNIVERSAL TYPE FUSE LINK 2070A1 15K-2 UNIVERSAL

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

Protistor size 70 gr 690VAC (IEC)

Protistor size 70 gr 690VAC (IEC) Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses CP No.: CP9716 Rev. 02 Page: 1 of 9 CERTIFIED TEST REPORT Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses Rev. 02 DATE: June 3, 2010 ORIGINAL REPORT DATE: June 13, 1997 Cooper Power Systems,

More information

S&C Recloser Bypass Disconnects

S&C Recloser Bypass Disconnects S&C Recloser Bypass Disconnects Outdoor Distribution (14.4 kv through 34.5 kv) Application S&C Recloser Bypass Disconnects are station-type devices used to bypass and isolate automatic circuit reclosers

More information

Electrical Protection

Electrical Protection Electrical Protection Excessive current in any electrical circuit is hazardous and not desired, and these maybe caused by the following; 1. Overloads, and 2. Short-circuits. Overload Currents: These are

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size. S&C Mini-Rupter es Indoor Distribution (4.16 kv through 25 kv) Selecting Standard Mounting Arrangements for Manually Operated Styles Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter

More information

S&C Manual PME Pad-Mounted Gear

S&C Manual PME Pad-Mounted Gear S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,

More information

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX File: PCUP-09-002_EX Outdoor Use Indoor Use The Trans-Guard EX full-range current-limiting capacitor fuse provides both low and high current fault protection in a single, compact fuse body. As a full-range

More information

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT Fusing Equipment Kearney Fuse Links Electrical Apparatus K-SEC 030 GENERAL Kearney fuse links can be applied to a variety of applications requiring overcurrent protection of distribution systems and equipment.

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break Part 1-GENERAL 1.1 DESCRIPTION Guide Specification Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break The switchgear shall consist of magnetically actuated solid dielectric insulated

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv) Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

IEC Standard Back-Up Fuse-Links

IEC Standard Back-Up Fuse-Links 3 / 7.2 kv 6 / 12 kv 10 / 17.5 kv 10 / 24 kv 20 / 36 kv Ferrule German DIN Standard Beyond our line of ANSI / IEEE current-limiting fuses, Mersen offers a full line of medium voltage fuse links according

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25

More information

ELF -LR current-limiting fuse

ELF -LR current-limiting fuse Fusing Equipment Catalog Data C132044EN Supersedes 240-71 ugust 2006 COOPER POWER SERIES ELF -LR current-limiting fuse General Eaton's Cooper Power series ELF -LR currentlimiting fuse is a full range current-limiting

More information

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A DISTRIBUTION SOLUTIONS Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A Continuous protection and reliable operation Proven design and compliance with newest fuses standards Compatibility with other ABB

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

LG HRC Power Fuses ISO 9001 ISO 14001

LG HRC Power Fuses ISO 9001 ISO 14001 LG HRC Power Fuses ISO 900 ISO Current without Power Fuse (ka ms) Ipeak Let through Below 0.5 Cycle voltage(kv) Initiation of 3. 7. 5.5 3 arcing(degree) Ipeak(kA) Power Factor 5 5 90 5 70 9 0 7 7 7 5 5

More information