Level Switches. Level Float Switch. Visual/Electrical Low Level. LEN Series RL Series. LV/E1 Series. S e c t i o n
|
|
- Liliana Hoover
- 6 years ago
- Views:
Transcription
1 Level Switches Level Float Switch LEN Series RL Series Visual/Electrical Low Level LV/E1 Series S e c t i o n 5
2 Level Float Switch - LEN Series The electromagnetic level indicator activates an electric signal when the fluid inside the tank reaches a stated level. LEN series is available with three hole flanges or with a 1" BSP threaded connection, with 1 or floats, in a standard range of lengths. 5-1 The float traveling up and down the tube contains a magnet: when the float reaches the reed switch enclosed in the tube, the magnet causes the contact to close (or open). Technical Data Materials: Connector: Plastic Flange: luminum Tube: Brass Float: Plastic Electrical Data: N.C. to N.O. Conversion: Working Pressure: Working Temperature: Warning: Power communicable to DC: 60W Power communicable to C: 80V DC current intensity: 1.3 C current intensity: Communicable voltage: 50V Frequency: 50 Hz/60 Hz Capacitance of open contacts: 4pF Insulation resistance 10 ohms Connector protection: IP 65 To convert an "LEN" from N.C. to N.O. or vice versa, remove the bottom "C" clip on the rod, turn the float upside down and replace both the float and "C" clip. 40 PSI For higher pressure, please consult Technical Dept. From -0ºC to +100ºC These indicators are designed for vertical installation. The float must be at least 35 mm away from any ferrous surface.
3 Installation Data LEN Series Dimensions 1 Float Size H(mm) Electrical Diagrams MINIMUM THRED LENGTH IN THE TNK 1 mm 5- SINGLE FLOT Dimensions Floats Size H(mm) H1(mm) Electrical Diagrams 3 T DOUBLE FLOT
4 Ordering Information LEN Series LEN F S SERIES CONNECTOR 5-3 LEN Complete Indicator S DIN TUBE MTERIL Brass MOUNTING SIZE F G Flange 1 BSP 150 SELS 50 Nitrile (Buna-N) SWITCHING CONTCTS 1 1 contact FLOTS 1 1 float (up to size 350) float (from size ) FLOT MTERIL Plastic
5 Level Float Switch - RL Series Rapid Level Float Switch. Revolutionary new series of electro-magnetic level gauges. Packed in "Kit" form. Only a few seconds are required to obtain the desired length: just cut the control rod to length. There are no electrical components submersed in the fluid. Can be used in heavily contaminated fluids and refrigerating oils. Tolerates the presence of metallic particles. Multiple switching options are available to customize your system. Models suitable for high temperatures and corrosive liquids are available. 5-4 Technical Data Wiring Schematics: (absence of fluid) S1 1 S 3 S3 ELECTRICL CONNECTOR LOCTION SEL PCKING OR GSKET POSITION SWITCH (S) S3=S1+S1 Switch Specifications: Exchange Contact Switch: Open or closed contacts switch Standard: 3. 60W. 60 V.. 50V On request: V. 50V 1 30W. 60 V.. 0V 1 POSITION SWITCH (S1) MGNET Mounting Pattern F3: COMPRESSION JOINT CONTROL ROD (WITH FLOT ND MGNET SSEMBLED) Ø34.6 LR - F3 QUICK MOUNTING ROD/FLOT CONNECTOR FLOT (IN PLSTIC) Each level is supplied outfitted with screws and oiltight gasket
6 How To Cut The Rapid Level Rod L/L1 B L/L1 B L = = B = Liquid Level in mm Minimum Rod Level in mm Maximum Rod Level in mm H = H = H1 = H1 = 60 (L = 10:500 mm) 90 (L = 501:1000 mm) 70 (L = 10:1000 mm) 33 (L = 85 mm) When measuring length of rod for cutting, Don't forget to keep the rod extended!
7 RL/G1 Series - Single Float Packed in a kit form which includes the head/ connector assembly, control rod and float. CONNECTOR REED- CRRYING HED (NYLON GLSS) 8mm 15mm Switches are in the head assembly thus there are no wires to position inside the control rod. The control rod is stainless steel and can be cut to length easily. The float is fixed to the control rod and does not contain any magnets. This eliminates the collection of ferrous material present in some fluids. The control rod and float move as one piece into the head assembly to actuate the switches. Standard model is supplied with control rod closing the switch with falling oil level. If you need open contacts add "" to the standard code. ie: RLG1-F3-S3 "" L Level CONTROL ROD (STINLESS STEEL) FLOT (PLSTIC) 1-1/4" NPT 55mm For lengths over 500 mm or in systems with turbulence in the tank, specify type "R" reinforced rods. Mounting connection: T3: 1-1/4" NPT thread F3: Flange 3 mounting holes 5-6 RL/G Series - Double Float 8mm 15mm The RL/G's head accepts two control rods. Each control rod activates a separate switch. Each switch can be wired with S1, S, S3, configuration. This option allows a wide variety of signal options. For lengths over 500mm or in systems with turbulence in the tank, specify the "R" reinforced rod. L L1 The standard model is supplied with control rod 1 closing the switch contacts with falling oil level and control rod closing the switch contacts with rising oil level. For open switch contacts add "" to the standard code. Mounting Connection: T3 = 1-1/4" NPT thread F3 = Flange, 3 mounting holes. CONTROL ROD IN STINLESS STEEL UPPER LEVEL CONTROL ROD IN STINLESS STEEL LOWER LEVEL
8 RL/L Series - Side Mount Rapid Level lateral electro-magnetic levels packed in "Kit" form. 5-7 This model mounted on the side of the tank, has the same basic design as the tank top version. Unlike the tank top models, the distance between the first and second signal is not fixed. s the length of the control rod increases the distance between the two signals increases (see graph). Example using graph: The hydraulic pump is allowed to operate through the cross hatched range. When the oil level reaches line 1 a low oil level warning signal is generated. When the oil level drops to line 3 the system is automatically shut down.
9 Ordering Information RL Series Single Float RL-G1 - F3 S1 500 SERIES CONTROL ROD (LOWER) RL-G1 One Float Type 500 Standard Rod 500mm RL-L Single Float Side Mounting 1000 Standard Rod 1000mm - R F3 T3 ROD TYPE Double Float Standard Rod Reinforced rod FSTENING TYPE 3 Hole flange 1-1/4" NPT WIRING SCHEME Condition in the absence of liquid Normally Closed S1 N/ for RL-L S S3 Normally Open S1 N/ for RL-L S S3 Consult MP Filtri for high temperature and corrosive liquid options 5-8 RL-G R F3 S1 S B900 SERIES CONTROL ROD (UPPER) RL-G Double Float Type B400 Standard Rod 400mm B900 Standard Rod 900mm WIRING SCHEME RL-G LOWER FLOT Condition in the absence of liquid WIRING SCHEME RL-G UPPER FLOT Condition in the presence of liquid Normally Closed Normally Open Normally Closed Normally Open S1 S1 S1 S1 S S S S S3 S3 S3 S3
10 Visual Indicator and Electrical Level Switch - LV/E1 Series 5-9 One part provides two functions, visual level indicator and electrical low level switch which reduces costs. ll electrical components are mounted outside of the tank, totally isolated from the liquid. U shaped shield protects sight gauge Graduated scale for locating level of liquid. vailable in 5" and 10" lengths. vailable as "Normally Open" (NO) or Exchange Contacts (NO) or (NC) in the presence of liquid. Single Pole Single Throw (SPST) contact. Switch specifications: 1, 0W, V. Externally mounted, magnetically operated reed switch. Optional probe thermometer. Dimensions B Size B C D C LV/E mm 6.03" 35 mm 1.379" 13 mm 0.51" 17 mm 5.00" LV/E mm 11.0" 35 mm 1.379" 13 mm 0.51" 54 mm 10.00" D Ordering Information * 5" Visual/Electrical Gauge 10" Visual/Electrical Gauge Normally Open Contacts (NO) Exchange Contacts Normally Open Contacts (NO) with temperature probe Exchange Contacts with temperature probe * Condition in the presence of liquid LV/E M1 - NO LV/E M1 - Change LV/E M1 - NO - T LV/E M1 - Change - T LV/E M1 - NO LV/E M1 - Change LV/E M1 - NO - T LV/E M1 - Change - T
ELECTROMAGNETIC LEVELS
ELECTROMGNETIC LEVELS Precision and functionality, control points single or multiple, different materials to meet the various requirements of application. 8 IEG-TC1 1/2 IEG-TC2 1/2 ELECTROMGNETIC LEVEL
More informationLevel Gauges and Breather Plug
Level Gauges and Breather Plug 1. External mounting and embedded level gauges are available 2. Multi-points electrical control and temperature display or temperature control 3. Good sealing performance,
More informationHousing: black plastic Measuring element: copper spring. Protection rate: IP31 Threaded: axial type. Setting: 0 10 bar (0 150 psi)
DESCRIPTION The wide range of FI FILTRI indicators, covers all industrial applications. They are directly installed on the filter, and allow a complete control of the clogging level of the element. This
More informationLEVEL SWITCH WITH 1 FLOAT
RIL210 LEVEL SWITCH WITH 1 FLOAT LEVEL Immersion level controller with 1 or 2 control points It can be used for dirty liquids, water, petroleum, cutting oils, and tolerates the presence of metal and ferrous
More informationThe range of products is completed by a number of accessories, including:
ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not
More informationThe Discussion of this exercise covers the following points:
Exercise 2 Float Switch EXERCISE OBJECTIVE Learn the working principle of float switches and how to use the float switch, Model 46935. DISCUSSION OUTLINE The Discussion of this exercise covers the following
More informationSP/SF Series Flow Switches
ISO-9001:2000 certified SP/SF Series Flow Switches More than just another level measurement company. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION SP SERIES OPERATING PRINCIPLE SP SERIES The SP Series
More informationFluid Cooling Industrial COLW Series
Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned
More informationATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor
ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300
More informationCTR* /103 ED HYDRAULIC POWER PACKS TANK CAPACITY PUMP FLOW RATE SERIES 30. from 8 lt to 150 lt. from 1,6 lt to 77 lt ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈
96 000/103 ED CTR HYDRAULIC POWER PACKS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 77 lt DESCRIPTION STANDARD COMPONENTS The CTR power packs, are realised with a soaked gear pump and
More informationMultiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous
Proximity Limit Switch The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous metals. All components are sealed and protected within the rugged brass housing eliminating
More informationPlastic tube variable area flowmeter for liquids and gases
Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)
More informationM-100 Adjustable flow switch with right-angle flow
M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification
More informationD e s c r i p t i o n
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationMODEL FR20 & OLV-20 MAGNETIC FLOAT LEVEL SENSOR
MODEL FR20 & OL-20 MGNETI FLOT LEEL ENOR Operational Description These level sensors contain hermetically sealed reed switches in the stem and a permanent magnet in the float. s a float rises or falls
More informationDimensions / Technical Data / Order Codes
Fluid Level / Temperature Indicators / / rder odes Level Gauge SN D Design of Scale Plates Thermometer ptions apillary Tube Thermometer with a dual elsius / Fahrenheit scale up to +80 / +80 F L3 YUR LG
More informationPF6 Stainless Steel Piston Actuated On/ Off Valves
Page of TI-P7- CH Issue Cert. No. LRQ 9 ISO 9 PF Stainless Steel Piston Actuated On/ Off Valves Description A -port pneumatically actuated on / off stainless steel valve for use on steam, water, air, oil
More informationAGILENT VACUUM VALVEs
GILENT VCUUM valves 2-3 gilent Vacuum Valve Solutions 4-17 gilent High Performance Valves 18-21 Stainless Steel Tube Valves 22-23 Electromagnetic Block Valves 24 Variable Leak Valves gilent Vacuum Valve
More informationAGILENT VACUUM VALVES
GILENT VCUUM VLVES 2-3 gilent Vacuum Valve Solutions 4-23 gilent High Performance Valves 24-27 Stainless Steel Tube Valves 28-29 Electromagnetic Block Valves 30 Variable Leak Valves GILENT VCUUM VLVE SOLUTIONS
More informationData sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472
Data sheet 2-way solenoid valves with Clip-on coils for neutral liquids and gases January 200 DKACV.PD.200.K.22 520B472 2 DKACV.PD.200.K.22 Danfoss A/S 0-200 Contents 2-way solenoid valves with Clip-on
More informationPF6 Stainless Steel Piston Actuated On/Off Valves
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information8020 Series Snap-acting Momentary Pushbutton Switches
Snap-acting Momentary Switches Features/Benefits Positive tactile feel Multi-positions available Wide variety of termination options Epoxy terminal seal compatible with bottom wash cleaning RoHS compliant
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail
More informationAV 23 Balancing valves SETTER Inline
AV Balancing valves SETTER Inline Application Direct reading and balancing valve with visual flow indication. Correct balancing of circuits ensure optimum efficiency of the system and can therefore help
More informationD e s c r i p t i o n
e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into
More informationCTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL
96 000/117 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41 lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted
More informationTABLE OF CONTENTS PRESSURE SPA... 4 SWA... 6 SMA... 8 SDCA...10 SKBA...12 SKDA...14 SPAL...16 SLF...18 SPAH...20 DIFFERENTIAL DSPA...22 VACUUM SVA...24 SPVL...26 TEMPERATURE S1TAF...28 S2TAF...30 TRANSDUCER
More informationGUARDIAN VERTICAL MOUNTING
GUARDIAN VERTICAL MOUNTING L120 GUARDIAN INDUSTRIAL & ATEX Exi VERTICAL REED LEVEL SWITCH This rnge of mgnet operted reed switches re equipped with hermeticlly seled reed contcts. The flot is fitted with
More informationLevel switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description
edit. II 2015/ page 1 Level switches (two-term level controllers) ERH-xx-04,-06,-07,6,6.1 Description The limit level signalling or two-term liquid level control in the open or closed pressure tanks. The
More informationMiniature Liquid Level Sensors
C US File No. 1636 (L90200-27) Applications Typical applications include automatic vending machines, photocopiers, small collection tanks, miniature pumping stations, pilot plants and similar small system
More informationSERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm
SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows
More informationC&K 8020 Series Snap-acting Momentary Pushbutton Switches
Features/Benefits Positive tactile feel Multi-positions available Wide variety of termination options Epoxy terminal seal compatible with bottom wash cleaning RoHS complient models available Typical pplications
More information2-Way Zone Valves, Brass Threaded, Sweat, Flare, Inverted Flare (1/2 to 1-1/4 in.) with Electric Actuators
1 Part Numbering System Two Position, ctuator Zone Valve V X X X X X X X X X XX X 2 y s, s ade t,, Body Type & Temperature T = On/Off (General) S = On/Off (Steam) High temperature actuator must be used.
More information3-Way Zone Valves, Brass Threaded (1/2 to 1 in.), Sweat (1/2 to 1-1/4 in.) with Electric Actuators
1 Part Numbering System Two Position, ctuator Zone Valve 3-way zone valves V X 3 X X X X 1 X X XX X 2 Body Type & Temperature T = On/Off (General) S = On/Off (Steam) High temperature actuator must be used.
More informationACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]
ACME SCREW LINEAR ACTUATOR ATL 02 Stroke Actuator with DC motor La =Lc + Stroke Lc T OVERALL DIMENSIONS Rear bracket SP Pin Actuator with or 3-phase motor Capacitor Stroke end reed switches FCM Motor cable
More informationQBV SERIES Butterfly Valves
QV SERIES utterfly Valves KEY HIGH VUUM PROUTS, IN.'s QV Series butterfly valves are designed and manufactured to offer reliable performance, be versatile and offer an economic benefit. These valves have
More informationSPIN-ON FILTER - LOW PRESSURE LINE
SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises
More informationCORROSION RESISTANT IN LINE FLOW SWITCHES
ULTRASWITCH P20 SERIES CORROSION RESISTANT IN LINE FLOW SWITCHES Magnetically sprung piston provides exceptional reliability FEATURES SUITS TUBES & PIPES 6 TO 20 MM ( 1 /4 TO /4 ) DIA. NO METAL PARTS IN
More informationENVIROMUX Series E-LLS-SF-10/25CM. Stainless Steel Vertical Liquid Level Float Switch. Installation Instruction. Description.
ENVIROMUX Series E-LLS-SF-10/25CM Stainless Steel Vertical Liquid Level Float Switch Installation Instruction Description The action of the E-LLS-SF-xxCM Float Switch is straight forward and simple. Mount
More informationGTV Series High Pressure Control Valves
For primary and secondary shut off of fuel control lines Keeping the World Flowing Contents Section Page Technical Specification 3 ¾" & " 2-Way Poppet Valve 4 ¾" & " 3-Way Poppet Valve 5 /2", 2" & 3" 2-Way
More informationFlowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.
Flowmeters with Float Series 6001/ 6002 Flow Measurement of Gases & Clear Liquids with Float Series 6001 & 6002. Measurement Principle Variable area obtained by the displacement of a float in a conical,
More informationFS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology
Level Measurement and Monitoring FS10 Vertically-Mounted Magnetic Float Level Sensor reliable and robust, heavy-duty technology mounting thread, tank fitting or flange installation at top or bottom of
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationTECHNICAL CATALOGUE BUILD-IN VALVES AND SUPPLY STOPS
TECHNICL CTLOGUE BUILD-IN VLVES ND SUPPLY STOPS TEC ITP Sp, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds
More informationC&K 7000 Series Miniature Toggle Switches
Miniature Switches Models vailable Features/Benefits Multi-pole and multi-position Wide variety of actuator and termination options Epoxy sealed terminals prevent contamination during soldering Typical
More informationInstallation Instruction
CIVCON MNIFOLD INSTLLTION MNUL REVISION 5/9/05 PETROLEUM MNIFOLD for TNK TRUCKS Installation Instruction Unit of Knappco, Inc. Phone: 86-74-6600 Fax: 86-74-06 CIVCON MNIFOLD INSTLLTION MNUL REVISION 5/9/05
More informationACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor
ACME SCREW LINEAR ACTUATOR ATL 10 AC motor Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore 80 BA depth 17 Stroke end reed switches FCM
More informationGA 24 Heavy-duty variable area flowmeter
KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationBooster Pump Control Valve
MODEL 60-7 660-7 ooster Pump Control Valve Simple Hydraulic Operation Low Head Loss Horizontal or Vertical Mounting uilt-in Check Valve Proven Reliable Design The Cla-Val Model 60-7/660-7 ooster Pump Control
More informationXL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL
XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline,
More information8500 Series Subminiature Pushbutton Switches
8500 Series Features/Benefits Pre-travel or over-travel models available Ratings up to 3 MPS Reliable contact design RoHS compliant Typical pplications Detection Telecommunications and networking equipment
More informationCHOOSING YOUR MANIFOLD & LOCATION
CHOOSING YOUR MANIFOLD & LOCATION THOUGHTS ON ZONING The function of a manifold is to distribute the correct flow to each loop to meet its specific heating load. This is achieved by balancing each loop
More information2/2 Pressure operated valves
Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54
More informationNIVOMAG MAGNETIC LEVEL SWITCHES GENERAL DESCRIPTION MODEL SELECTION SUPPLEMENTARY DATA. Temperature diagram: Temperature specification for Ex versions
NIVOMAG MAGNETIC LEVEL SWITCHES FEATURES Magnetic coupling between the switch and the float Operation w/o external power supply Side or top mounted versions Underwater housing Fixed or variable hysteresis
More informationDistinctive Characteristics
Distinctive Characteristics ntirotation design, standard on noncylindrical levers, mates toggle and bushing; bottom of toggles has two flatted sides which fit into a complementary opening inside bushing.
More informationReed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA
> Series CST-CSV-CSH proximity switches Series CST - CSV and CSH magnetic proximity switches Reed, Electronic» Designed to fit into the grooves provided in the profile barrel of the cylinder» The three
More informationCTR* /108 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41lt
96 000/108 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted
More informationEP Series Sealed Tiny Pushbutton Switches
Sealed Tiny Switches Features/Benefits Sealed against solder & cleaning processes Thru-hole and surface mount models Snap-fitting actuator accepts standard caps Tape & reel packaging available RoHS compliant
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More informationA complete line of pressure differential visual and electrical indicators are available with this series of filters.
D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the
More informationBACKFLOW PREVENTERS DUAL-CHECK BACKFLOW PREVENTER WITH ATMOSPHERIC VENT T/S-459 Certified to ASSE Standard 1012
CKFLOW PREVENTERS DUL-CHECK CKFLOW PREVENTER WITH TMOSPHERIC VENT T/S-459 Certified to SSE Standard 1012 Certified to CS Standard 64.3 Forged brass construction Threaded or sweat true union end connections
More information7000 Series Miniature Toggle Switches
Models vailable Features/Benefits Multi-pole and multi-position Wide variety of actuator and termination options Epoxy sealed terminals prevent contamination during soldering Typical pplications Telecommunications
More informationCheck Valves. E Check Valves E-1. Quick Coupling Division 8145 Lewis Road Minneapolis, MN
Check Valves E-1 Check Valves Introduction Multiple Hydraulic System pplications Parker Check Valves are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage
More informationFA/FB Series Cable Float Level Switch
ISO-9001:000 certified FA/FB Series Cable Float Level Switch More than just another level measurement company. Aplus Finetek Sensor, Inc. INTRODUCTI DESCRIPTI The FA/FB series are cable float type level
More informationCooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION
Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationPROCESS & AUTOMATED VALVES
Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline
More informationElectrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)
Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =
More informationContact Dial Thermometer
Data sheet 608523 Page 1/8 Contact Dial Thermometer Special features Class 1.5 Display range -40 C to +600 C Temperature controller with actual value display as built-in or add-on device in the stainless
More informationPISTON STYLE GAUGE. Mid-West Instrument
PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential
More informationSOLENOID VALVES AND PNEUMATIC VALVES
A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly
More informationSALIENT FEATURES: Model Model 2000S
DK's magnetic flow switch is the product of two decades knowledge in thermal power station, fertilizer & chemical industries. Flow switch is the target type unit that works on the magnetic principle of
More informationBERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features
Booster Pump Control Valve Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More information2-Way & 3-Way Non Spring Return Characterized Ball Valves
VCB30 Series Revision Date June 6, 2014 2-Way & 3-Way Non Spring Return Characterized Ball Valves General The VCB30 Series electric rotary-motion actuatordriven characterized ball valves are designed specifically
More informationANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)
ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) BRASS OR STAINLESS STEEL BODY POLYMER OR METAL ACTUATOR HERION USA Inc. Valve Technology and Systems Brochure N-285 Multi-Accessory Polymer Head versions Increased
More information2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm
/ or 3/-way Solenoid Valve, with pivoted armature and isolating diaphragm Type 0330 can be combined with Lockable manual override as standard For liquid, gaseous and aggressive media Long service life,
More informationMSRT 150. Oil Temperature Indicator for Power Transformer type :
Oil Temperature Indicator for Power Transformer type : MSRT 150 Introduction Description and general specifications Options Operating instructions and maintenance Finished product quality control tests
More informationAnodized Aluminum Manifolds
nodized luminum Manifolds These manifolds can t rust, they resist corrosion and cost less! Made from heavy-wall aluminum extrusions, tested to 120 psi. Standard manifolds have 1" or 1¹ ₂" process water
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0
More informationGACHOT TYPE V16 BALL VALVES CARBON STEEL / FULL BORE / DN 8 TO DN 150
CRBON STEEL / FULL BORE / DN 8 TO DN 150 Carbon steel, forged body full bore ball valve designed to international and European standards FETURES PPLICTIONS Saturated steam. mmonia, natural gas, propane
More informationL312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Multi-Point, Vertically-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the Multi-
More informationSERIES V. High Performance Segmented Ball Valve
SERIES V High Performance Segmented Ball Valve Publication SV000-101 Issue 02/17 Rev. D General Information High Rangeability: 300:1 Turn down ratio Flow Characteristic: Equal Percentage Low Pressure Recovery
More information2 1 /2" Glycerin-Filled Dual Scale Vacuum Gauges
BAC-25 Brass Case Dial Size: 2 1 /2" Glycerin Filled Pressure Ranges: 30" HG to 15,000 PSI/Bar (Dual Scale) Accuracy: Within 1.5% of Maximum Graduation Case: Forged Brass With Polished Brass ABS Bourdon
More informationC&K ET Series Sealed Subminiature Toggle Switches
Models vailable Features/Benefits Sealed against solder and cleaning process contaminants ESD protection available Thru-hole and surface mount models Compact sizeand small footprint save PCB space Typical
More informationLiquid level switch Type AKS 38
Data sheet Liquid level switch Type AKS 38 AKS 38 is an electro-mechanical liquid level switch designed to provide a reliable, electromechanical response to liquid level changes. The simple and basic design
More informationField IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage
Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use
More informationBALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE
BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS BSA 10 AC motor Stroke La =Lc + Stroke Lc Capacitor T Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth 17 Stroke end reed switches FCM
More informationLevel instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.
Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate
More informationGVI Series Industrial Globe Valves for Flow Control
Series Industrial Globe Valves for Flow Control 2-way Flow Control Globe Valves ssured utomations Series Industrial Globe Valves are contructed with rugged carbon steel or stainless steel bodies. They
More informationMB SERIES SMB SERIES MINIATURE TANK BREATHERS MINIATURE TANK BREATHERS ACCCESSORIES. Phone (608) Fax (608)
G1 MB SERIES MINIATURE TANK BREATHERS 10 Micron Filtration (Nominal) Shatter Resistant Plastic Construction Temperatures Up to +225 F Model A B Number Thread Size Overall Height MB-02-10 1/4 NPT 1.8 MB-03-10
More informationMERCURY CONTACTORS & RELAYS
MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND
More informationD-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features
D26.SWG.CAT.ENG0 D-26 Wastewater Combination Air Valve for Wastewater Description The D-26 Combination Air Valve combines an air & vacuum component and an air release component in a single body. The valve
More informationBehringer Ball Valve Ordering Code
Ball Valve Catalog Behringer Ball Valve Ordering Code 1 Behringer 2-Way Ball Valves Block Body Valves with Threaded Connections Size Range: 1/4-1 Steel Material Delrin Ball Seats (Others available on request)
More informationNOW UL LISTED. Patented
NOW UL LISTED Patented Ø1.730 Ø 1.765 Ø.922 4.15 8.71 TOP VIEW 1.50 2" NPS THRDS. BOTTOM VIEW 2.13 2.14 SIDE VIEW 2.000 CLAY & BAILEY MFG. CO. 2" FILL SHUT OFF VALVE DATE:10/25/05 01228-03-2200 2" X 4"
More information12AT/50AT Series Spin-On Filters
1 Applications for Mobile Equipment Hydrostatic Drives Industrial Power Units Reservoir Breathers Often, economic conditions dictate what type of filter is used on a piece of equipment. When costs are
More informationAPG. LF - Miniature Liquid Level Sensors
LF - Miniature Liquid Level Sensors The LF Miniature Liquid Level sensors are designed for reliable operation in small tanks and containers. Their rugged design and multiple configurations make them the
More informationStainless Steel Trim Standard. ir and Vacuum Sewer Valves permit a large volume of air to
ir and Vacuum Sewer Valves Valve Functio n Exhausts air as a pipeline fills, and allows air in as pipeline drains Features Include Standard and short body series available vailable in sizes thru 10 ll
More informationQSS: Quick Set System. Product Catalog Compression Sleeve Valves and Fittings to 15,000 psi (1034 bar)
QSS: Quick Set System Product Catalog Compression Sleeve Valves and Fittings to psi (1034 bar) Section Page Introduction.............................. 2 QS Needle Valves........................... 4 QS
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More information9012G Pressure and 9016G Vacuum Switches
Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:
More information