Level Switches. Level Float Switch. Visual/Electrical Low Level. LEN Series RL Series. LV/E1 Series. S e c t i o n

Size: px
Start display at page:

Download "Level Switches. Level Float Switch. Visual/Electrical Low Level. LEN Series RL Series. LV/E1 Series. S e c t i o n"

Transcription

1 Level Switches Level Float Switch LEN Series RL Series Visual/Electrical Low Level LV/E1 Series S e c t i o n 5

2 Level Float Switch - LEN Series The electromagnetic level indicator activates an electric signal when the fluid inside the tank reaches a stated level. LEN series is available with three hole flanges or with a 1" BSP threaded connection, with 1 or floats, in a standard range of lengths. 5-1 The float traveling up and down the tube contains a magnet: when the float reaches the reed switch enclosed in the tube, the magnet causes the contact to close (or open). Technical Data Materials: Connector: Plastic Flange: luminum Tube: Brass Float: Plastic Electrical Data: N.C. to N.O. Conversion: Working Pressure: Working Temperature: Warning: Power communicable to DC: 60W Power communicable to C: 80V DC current intensity: 1.3 C current intensity: Communicable voltage: 50V Frequency: 50 Hz/60 Hz Capacitance of open contacts: 4pF Insulation resistance 10 ohms Connector protection: IP 65 To convert an "LEN" from N.C. to N.O. or vice versa, remove the bottom "C" clip on the rod, turn the float upside down and replace both the float and "C" clip. 40 PSI For higher pressure, please consult Technical Dept. From -0ºC to +100ºC These indicators are designed for vertical installation. The float must be at least 35 mm away from any ferrous surface.

3 Installation Data LEN Series Dimensions 1 Float Size H(mm) Electrical Diagrams MINIMUM THRED LENGTH IN THE TNK 1 mm 5- SINGLE FLOT Dimensions Floats Size H(mm) H1(mm) Electrical Diagrams 3 T DOUBLE FLOT

4 Ordering Information LEN Series LEN F S SERIES CONNECTOR 5-3 LEN Complete Indicator S DIN TUBE MTERIL Brass MOUNTING SIZE F G Flange 1 BSP 150 SELS 50 Nitrile (Buna-N) SWITCHING CONTCTS 1 1 contact FLOTS 1 1 float (up to size 350) float (from size ) FLOT MTERIL Plastic

5 Level Float Switch - RL Series Rapid Level Float Switch. Revolutionary new series of electro-magnetic level gauges. Packed in "Kit" form. Only a few seconds are required to obtain the desired length: just cut the control rod to length. There are no electrical components submersed in the fluid. Can be used in heavily contaminated fluids and refrigerating oils. Tolerates the presence of metallic particles. Multiple switching options are available to customize your system. Models suitable for high temperatures and corrosive liquids are available. 5-4 Technical Data Wiring Schematics: (absence of fluid) S1 1 S 3 S3 ELECTRICL CONNECTOR LOCTION SEL PCKING OR GSKET POSITION SWITCH (S) S3=S1+S1 Switch Specifications: Exchange Contact Switch: Open or closed contacts switch Standard: 3. 60W. 60 V.. 50V On request: V. 50V 1 30W. 60 V.. 0V 1 POSITION SWITCH (S1) MGNET Mounting Pattern F3: COMPRESSION JOINT CONTROL ROD (WITH FLOT ND MGNET SSEMBLED) Ø34.6 LR - F3 QUICK MOUNTING ROD/FLOT CONNECTOR FLOT (IN PLSTIC) Each level is supplied outfitted with screws and oiltight gasket

6 How To Cut The Rapid Level Rod L/L1 B L/L1 B L = = B = Liquid Level in mm Minimum Rod Level in mm Maximum Rod Level in mm H = H = H1 = H1 = 60 (L = 10:500 mm) 90 (L = 501:1000 mm) 70 (L = 10:1000 mm) 33 (L = 85 mm) When measuring length of rod for cutting, Don't forget to keep the rod extended!

7 RL/G1 Series - Single Float Packed in a kit form which includes the head/ connector assembly, control rod and float. CONNECTOR REED- CRRYING HED (NYLON GLSS) 8mm 15mm Switches are in the head assembly thus there are no wires to position inside the control rod. The control rod is stainless steel and can be cut to length easily. The float is fixed to the control rod and does not contain any magnets. This eliminates the collection of ferrous material present in some fluids. The control rod and float move as one piece into the head assembly to actuate the switches. Standard model is supplied with control rod closing the switch with falling oil level. If you need open contacts add "" to the standard code. ie: RLG1-F3-S3 "" L Level CONTROL ROD (STINLESS STEEL) FLOT (PLSTIC) 1-1/4" NPT 55mm For lengths over 500 mm or in systems with turbulence in the tank, specify type "R" reinforced rods. Mounting connection: T3: 1-1/4" NPT thread F3: Flange 3 mounting holes 5-6 RL/G Series - Double Float 8mm 15mm The RL/G's head accepts two control rods. Each control rod activates a separate switch. Each switch can be wired with S1, S, S3, configuration. This option allows a wide variety of signal options. For lengths over 500mm or in systems with turbulence in the tank, specify the "R" reinforced rod. L L1 The standard model is supplied with control rod 1 closing the switch contacts with falling oil level and control rod closing the switch contacts with rising oil level. For open switch contacts add "" to the standard code. Mounting Connection: T3 = 1-1/4" NPT thread F3 = Flange, 3 mounting holes. CONTROL ROD IN STINLESS STEEL UPPER LEVEL CONTROL ROD IN STINLESS STEEL LOWER LEVEL

8 RL/L Series - Side Mount Rapid Level lateral electro-magnetic levels packed in "Kit" form. 5-7 This model mounted on the side of the tank, has the same basic design as the tank top version. Unlike the tank top models, the distance between the first and second signal is not fixed. s the length of the control rod increases the distance between the two signals increases (see graph). Example using graph: The hydraulic pump is allowed to operate through the cross hatched range. When the oil level reaches line 1 a low oil level warning signal is generated. When the oil level drops to line 3 the system is automatically shut down.

9 Ordering Information RL Series Single Float RL-G1 - F3 S1 500 SERIES CONTROL ROD (LOWER) RL-G1 One Float Type 500 Standard Rod 500mm RL-L Single Float Side Mounting 1000 Standard Rod 1000mm - R F3 T3 ROD TYPE Double Float Standard Rod Reinforced rod FSTENING TYPE 3 Hole flange 1-1/4" NPT WIRING SCHEME Condition in the absence of liquid Normally Closed S1 N/ for RL-L S S3 Normally Open S1 N/ for RL-L S S3 Consult MP Filtri for high temperature and corrosive liquid options 5-8 RL-G R F3 S1 S B900 SERIES CONTROL ROD (UPPER) RL-G Double Float Type B400 Standard Rod 400mm B900 Standard Rod 900mm WIRING SCHEME RL-G LOWER FLOT Condition in the absence of liquid WIRING SCHEME RL-G UPPER FLOT Condition in the presence of liquid Normally Closed Normally Open Normally Closed Normally Open S1 S1 S1 S1 S S S S S3 S3 S3 S3

10 Visual Indicator and Electrical Level Switch - LV/E1 Series 5-9 One part provides two functions, visual level indicator and electrical low level switch which reduces costs. ll electrical components are mounted outside of the tank, totally isolated from the liquid. U shaped shield protects sight gauge Graduated scale for locating level of liquid. vailable in 5" and 10" lengths. vailable as "Normally Open" (NO) or Exchange Contacts (NO) or (NC) in the presence of liquid. Single Pole Single Throw (SPST) contact. Switch specifications: 1, 0W, V. Externally mounted, magnetically operated reed switch. Optional probe thermometer. Dimensions B Size B C D C LV/E mm 6.03" 35 mm 1.379" 13 mm 0.51" 17 mm 5.00" LV/E mm 11.0" 35 mm 1.379" 13 mm 0.51" 54 mm 10.00" D Ordering Information * 5" Visual/Electrical Gauge 10" Visual/Electrical Gauge Normally Open Contacts (NO) Exchange Contacts Normally Open Contacts (NO) with temperature probe Exchange Contacts with temperature probe * Condition in the presence of liquid LV/E M1 - NO LV/E M1 - Change LV/E M1 - NO - T LV/E M1 - Change - T LV/E M1 - NO LV/E M1 - Change LV/E M1 - NO - T LV/E M1 - Change - T

ELECTROMAGNETIC LEVELS

ELECTROMAGNETIC LEVELS ELECTROMGNETIC LEVELS Precision and functionality, control points single or multiple, different materials to meet the various requirements of application. 8 IEG-TC1 1/2 IEG-TC2 1/2 ELECTROMGNETIC LEVEL

More information

Level Gauges and Breather Plug

Level Gauges and Breather Plug Level Gauges and Breather Plug 1. External mounting and embedded level gauges are available 2. Multi-points electrical control and temperature display or temperature control 3. Good sealing performance,

More information

Housing: black plastic Measuring element: copper spring. Protection rate: IP31 Threaded: axial type. Setting: 0 10 bar (0 150 psi)

Housing: black plastic Measuring element: copper spring. Protection rate: IP31 Threaded: axial type. Setting: 0 10 bar (0 150 psi) DESCRIPTION The wide range of FI FILTRI indicators, covers all industrial applications. They are directly installed on the filter, and allow a complete control of the clogging level of the element. This

More information

LEVEL SWITCH WITH 1 FLOAT

LEVEL SWITCH WITH 1 FLOAT RIL210 LEVEL SWITCH WITH 1 FLOAT LEVEL Immersion level controller with 1 or 2 control points It can be used for dirty liquids, water, petroleum, cutting oils, and tolerates the presence of metal and ferrous

More information

The range of products is completed by a number of accessories, including:

The range of products is completed by a number of accessories, including: ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 2 Float Switch EXERCISE OBJECTIVE Learn the working principle of float switches and how to use the float switch, Model 46935. DISCUSSION OUTLINE The Discussion of this exercise covers the following

More information

SP/SF Series Flow Switches

SP/SF Series Flow Switches ISO-9001:2000 certified SP/SF Series Flow Switches More than just another level measurement company. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION SP SERIES OPERATING PRINCIPLE SP SERIES The SP Series

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300

More information

CTR* /103 ED HYDRAULIC POWER PACKS TANK CAPACITY PUMP FLOW RATE SERIES 30. from 8 lt to 150 lt. from 1,6 lt to 77 lt ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈

CTR* /103 ED HYDRAULIC POWER PACKS TANK CAPACITY PUMP FLOW RATE SERIES 30. from 8 lt to 150 lt. from 1,6 lt to 77 lt ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ 96 000/103 ED CTR HYDRAULIC POWER PACKS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 77 lt DESCRIPTION STANDARD COMPONENTS The CTR power packs, are realised with a soaked gear pump and

More information

Multiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous

Multiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous Proximity Limit Switch The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous metals. All components are sealed and protected within the rugged brass housing eliminating

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

D e s c r i p t i o n

D e s c r i p t i o n D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

MODEL FR20 & OLV-20 MAGNETIC FLOAT LEVEL SENSOR

MODEL FR20 & OLV-20 MAGNETIC FLOAT LEVEL SENSOR MODEL FR20 & OL-20 MGNETI FLOT LEEL ENOR Operational Description These level sensors contain hermetically sealed reed switches in the stem and a permanent magnet in the float. s a float rises or falls

More information

Dimensions / Technical Data / Order Codes

Dimensions / Technical Data / Order Codes Fluid Level / Temperature Indicators / / rder odes Level Gauge SN D Design of Scale Plates Thermometer ptions apillary Tube Thermometer with a dual elsius / Fahrenheit scale up to +80 / +80 F L3 YUR LG

More information

PF6 Stainless Steel Piston Actuated On/ Off Valves

PF6 Stainless Steel Piston Actuated On/ Off Valves Page of TI-P7- CH Issue Cert. No. LRQ 9 ISO 9 PF Stainless Steel Piston Actuated On/ Off Valves Description A -port pneumatically actuated on / off stainless steel valve for use on steam, water, air, oil

More information

AGILENT VACUUM VALVEs

AGILENT VACUUM VALVEs GILENT VCUUM valves 2-3 gilent Vacuum Valve Solutions 4-17 gilent High Performance Valves 18-21 Stainless Steel Tube Valves 22-23 Electromagnetic Block Valves 24 Variable Leak Valves gilent Vacuum Valve

More information

AGILENT VACUUM VALVES

AGILENT VACUUM VALVES GILENT VCUUM VLVES 2-3 gilent Vacuum Valve Solutions 4-23 gilent High Performance Valves 24-27 Stainless Steel Tube Valves 28-29 Electromagnetic Block Valves 30 Variable Leak Valves GILENT VCUUM VLVE SOLUTIONS

More information

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472 Data sheet 2-way solenoid valves with Clip-on coils for neutral liquids and gases January 200 DKACV.PD.200.K.22 520B472 2 DKACV.PD.200.K.22 Danfoss A/S 0-200 Contents 2-way solenoid valves with Clip-on

More information

PF6 Stainless Steel Piston Actuated On/Off Valves

PF6 Stainless Steel Piston Actuated On/Off Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

8020 Series Snap-acting Momentary Pushbutton Switches

8020 Series Snap-acting Momentary Pushbutton Switches Snap-acting Momentary Switches Features/Benefits Positive tactile feel Multi-positions available Wide variety of termination options Epoxy terminal seal compatible with bottom wash cleaning RoHS compliant

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

AV 23 Balancing valves SETTER Inline

AV 23 Balancing valves SETTER Inline AV Balancing valves SETTER Inline Application Direct reading and balancing valve with visual flow indication. Correct balancing of circuits ensure optimum efficiency of the system and can therefore help

More information

D e s c r i p t i o n

D e s c r i p t i o n e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into

More information

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL 96 000/117 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41 lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted

More information

TABLE OF CONTENTS PRESSURE SPA... 4 SWA... 6 SMA... 8 SDCA...10 SKBA...12 SKDA...14 SPAL...16 SLF...18 SPAH...20 DIFFERENTIAL DSPA...22 VACUUM SVA...24 SPVL...26 TEMPERATURE S1TAF...28 S2TAF...30 TRANSDUCER

More information

GUARDIAN VERTICAL MOUNTING

GUARDIAN VERTICAL MOUNTING GUARDIAN VERTICAL MOUNTING L120 GUARDIAN INDUSTRIAL & ATEX Exi VERTICAL REED LEVEL SWITCH This rnge of mgnet operted reed switches re equipped with hermeticlly seled reed contcts. The flot is fitted with

More information

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description edit. II 2015/ page 1 Level switches (two-term level controllers) ERH-xx-04,-06,-07,6,6.1 Description The limit level signalling or two-term liquid level control in the open or closed pressure tanks. The

More information

Miniature Liquid Level Sensors

Miniature Liquid Level Sensors C US File No. 1636 (L90200-27) Applications Typical applications include automatic vending machines, photocopiers, small collection tanks, miniature pumping stations, pilot plants and similar small system

More information

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows

More information

C&K 8020 Series Snap-acting Momentary Pushbutton Switches

C&K 8020 Series Snap-acting Momentary Pushbutton Switches Features/Benefits Positive tactile feel Multi-positions available Wide variety of termination options Epoxy terminal seal compatible with bottom wash cleaning RoHS complient models available Typical pplications

More information

2-Way Zone Valves, Brass Threaded, Sweat, Flare, Inverted Flare (1/2 to 1-1/4 in.) with Electric Actuators

2-Way Zone Valves, Brass Threaded, Sweat, Flare, Inverted Flare (1/2 to 1-1/4 in.) with Electric Actuators 1 Part Numbering System Two Position, ctuator Zone Valve V X X X X X X X X X XX X 2 y s, s ade t,, Body Type & Temperature T = On/Off (General) S = On/Off (Steam) High temperature actuator must be used.

More information

3-Way Zone Valves, Brass Threaded (1/2 to 1 in.), Sweat (1/2 to 1-1/4 in.) with Electric Actuators

3-Way Zone Valves, Brass Threaded (1/2 to 1 in.), Sweat (1/2 to 1-1/4 in.) with Electric Actuators 1 Part Numbering System Two Position, ctuator Zone Valve 3-way zone valves V X 3 X X X X 1 X X XX X 2 Body Type & Temperature T = On/Off (General) S = On/Off (Steam) High temperature actuator must be used.

More information

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm] ACME SCREW LINEAR ACTUATOR ATL 02 Stroke Actuator with DC motor La =Lc + Stroke Lc T OVERALL DIMENSIONS Rear bracket SP Pin Actuator with or 3-phase motor Capacitor Stroke end reed switches FCM Motor cable

More information

QBV SERIES Butterfly Valves

QBV SERIES Butterfly Valves QV SERIES utterfly Valves KEY HIGH VUUM PROUTS, IN.'s QV Series butterfly valves are designed and manufactured to offer reliable performance, be versatile and offer an economic benefit. These valves have

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

CORROSION RESISTANT IN LINE FLOW SWITCHES

CORROSION RESISTANT IN LINE FLOW SWITCHES ULTRASWITCH P20 SERIES CORROSION RESISTANT IN LINE FLOW SWITCHES Magnetically sprung piston provides exceptional reliability FEATURES SUITS TUBES & PIPES 6 TO 20 MM ( 1 /4 TO /4 ) DIA. NO METAL PARTS IN

More information

ENVIROMUX Series E-LLS-SF-10/25CM. Stainless Steel Vertical Liquid Level Float Switch. Installation Instruction. Description.

ENVIROMUX Series E-LLS-SF-10/25CM. Stainless Steel Vertical Liquid Level Float Switch. Installation Instruction. Description. ENVIROMUX Series E-LLS-SF-10/25CM Stainless Steel Vertical Liquid Level Float Switch Installation Instruction Description The action of the E-LLS-SF-xxCM Float Switch is straight forward and simple. Mount

More information

GTV Series High Pressure Control Valves

GTV Series High Pressure Control Valves For primary and secondary shut off of fuel control lines Keeping the World Flowing Contents Section Page Technical Specification 3 ¾" & " 2-Way Poppet Valve 4 ¾" & " 3-Way Poppet Valve 5 /2", 2" & 3" 2-Way

More information

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle. Flowmeters with Float Series 6001/ 6002 Flow Measurement of Gases & Clear Liquids with Float Series 6001 & 6002. Measurement Principle Variable area obtained by the displacement of a float in a conical,

More information

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology Level Measurement and Monitoring FS10 Vertically-Mounted Magnetic Float Level Sensor reliable and robust, heavy-duty technology mounting thread, tank fitting or flange installation at top or bottom of

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

TECHNICAL CATALOGUE BUILD-IN VALVES AND SUPPLY STOPS

TECHNICAL CATALOGUE BUILD-IN VALVES AND SUPPLY STOPS TECHNICL CTLOGUE BUILD-IN VLVES ND SUPPLY STOPS TEC ITP Sp, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds

More information

C&K 7000 Series Miniature Toggle Switches

C&K 7000 Series Miniature Toggle Switches Miniature Switches Models vailable Features/Benefits Multi-pole and multi-position Wide variety of actuator and termination options Epoxy sealed terminals prevent contamination during soldering Typical

More information

Installation Instruction

Installation Instruction CIVCON MNIFOLD INSTLLTION MNUL REVISION 5/9/05 PETROLEUM MNIFOLD for TNK TRUCKS Installation Instruction Unit of Knappco, Inc. Phone: 86-74-6600 Fax: 86-74-06 CIVCON MNIFOLD INSTLLTION MNUL REVISION 5/9/05

More information

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor ACME SCREW LINEAR ACTUATOR ATL 10 AC motor Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore 80 BA depth 17 Stroke end reed switches FCM

More information

GA 24 Heavy-duty variable area flowmeter

GA 24 Heavy-duty variable area flowmeter KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

Booster Pump Control Valve

Booster Pump Control Valve MODEL 60-7 660-7 ooster Pump Control Valve Simple Hydraulic Operation Low Head Loss Horizontal or Vertical Mounting uilt-in Check Valve Proven Reliable Design The Cla-Val Model 60-7/660-7 ooster Pump Control

More information

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline,

More information

8500 Series Subminiature Pushbutton Switches

8500 Series Subminiature Pushbutton Switches 8500 Series Features/Benefits Pre-travel or over-travel models available Ratings up to 3 MPS Reliable contact design RoHS compliant Typical pplications Detection Telecommunications and networking equipment

More information

CHOOSING YOUR MANIFOLD & LOCATION

CHOOSING YOUR MANIFOLD & LOCATION CHOOSING YOUR MANIFOLD & LOCATION THOUGHTS ON ZONING The function of a manifold is to distribute the correct flow to each loop to meet its specific heating load. This is achieved by balancing each loop

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

NIVOMAG MAGNETIC LEVEL SWITCHES GENERAL DESCRIPTION MODEL SELECTION SUPPLEMENTARY DATA. Temperature diagram: Temperature specification for Ex versions

NIVOMAG MAGNETIC LEVEL SWITCHES GENERAL DESCRIPTION MODEL SELECTION SUPPLEMENTARY DATA. Temperature diagram: Temperature specification for Ex versions NIVOMAG MAGNETIC LEVEL SWITCHES FEATURES Magnetic coupling between the switch and the float Operation w/o external power supply Side or top mounted versions Underwater housing Fixed or variable hysteresis

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics ntirotation design, standard on noncylindrical levers, mates toggle and bushing; bottom of toggles has two flatted sides which fit into a complementary opening inside bushing.

More information

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA > Series CST-CSV-CSH proximity switches Series CST - CSV and CSH magnetic proximity switches Reed, Electronic» Designed to fit into the grooves provided in the profile barrel of the cylinder» The three

More information

CTR* /108 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41lt

CTR* /108 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41lt 96 000/108 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted

More information

EP Series Sealed Tiny Pushbutton Switches

EP Series Sealed Tiny Pushbutton Switches Sealed Tiny Switches Features/Benefits Sealed against solder & cleaning processes Thru-hole and surface mount models Snap-fitting actuator accepts standard caps Tape & reel packaging available RoHS compliant

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the

More information

BACKFLOW PREVENTERS DUAL-CHECK BACKFLOW PREVENTER WITH ATMOSPHERIC VENT T/S-459 Certified to ASSE Standard 1012

BACKFLOW PREVENTERS DUAL-CHECK BACKFLOW PREVENTER WITH ATMOSPHERIC VENT T/S-459 Certified to ASSE Standard 1012 CKFLOW PREVENTERS DUL-CHECK CKFLOW PREVENTER WITH TMOSPHERIC VENT T/S-459 Certified to SSE Standard 1012 Certified to CS Standard 64.3 Forged brass construction Threaded or sweat true union end connections

More information

7000 Series Miniature Toggle Switches

7000 Series Miniature Toggle Switches Models vailable Features/Benefits Multi-pole and multi-position Wide variety of actuator and termination options Epoxy sealed terminals prevent contamination during soldering Typical pplications Telecommunications

More information

Check Valves. E Check Valves E-1. Quick Coupling Division 8145 Lewis Road Minneapolis, MN

Check Valves. E Check Valves E-1. Quick Coupling Division 8145 Lewis Road Minneapolis, MN Check Valves E-1 Check Valves Introduction Multiple Hydraulic System pplications Parker Check Valves are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage

More information

FA/FB Series Cable Float Level Switch

FA/FB Series Cable Float Level Switch ISO-9001:000 certified FA/FB Series Cable Float Level Switch More than just another level measurement company. Aplus Finetek Sensor, Inc. INTRODUCTI DESCRIPTI The FA/FB series are cable float type level

More information

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

PROCESS & AUTOMATED VALVES

PROCESS & AUTOMATED VALVES Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline

More information

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =

More information

Contact Dial Thermometer

Contact Dial Thermometer Data sheet 608523 Page 1/8 Contact Dial Thermometer Special features Class 1.5 Display range -40 C to +600 C Temperature controller with actual value display as built-in or add-on device in the stainless

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

SALIENT FEATURES: Model Model 2000S

SALIENT FEATURES: Model Model 2000S DK's magnetic flow switch is the product of two decades knowledge in thermal power station, fertilizer & chemical industries. Flow switch is the target type unit that works on the magnetic principle of

More information

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features Booster Pump Control Valve Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

2-Way & 3-Way Non Spring Return Characterized Ball Valves

2-Way & 3-Way Non Spring Return Characterized Ball Valves VCB30 Series Revision Date June 6, 2014 2-Way & 3-Way Non Spring Return Characterized Ball Valves General The VCB30 Series electric rotary-motion actuatordriven characterized ball valves are designed specifically

More information

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) BRASS OR STAINLESS STEEL BODY POLYMER OR METAL ACTUATOR HERION USA Inc. Valve Technology and Systems Brochure N-285 Multi-Accessory Polymer Head versions Increased

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm / or 3/-way Solenoid Valve, with pivoted armature and isolating diaphragm Type 0330 can be combined with Lockable manual override as standard For liquid, gaseous and aggressive media Long service life,

More information

MSRT 150. Oil Temperature Indicator for Power Transformer type :

MSRT 150. Oil Temperature Indicator for Power Transformer type : Oil Temperature Indicator for Power Transformer type : MSRT 150 Introduction Description and general specifications Options Operating instructions and maintenance Finished product quality control tests

More information

Anodized Aluminum Manifolds

Anodized Aluminum Manifolds nodized luminum Manifolds These manifolds can t rust, they resist corrosion and cost less! Made from heavy-wall aluminum extrusions, tested to 120 psi. Standard manifolds have 1" or 1¹ ₂" process water

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0

More information

GACHOT TYPE V16 BALL VALVES CARBON STEEL / FULL BORE / DN 8 TO DN 150

GACHOT TYPE V16 BALL VALVES CARBON STEEL / FULL BORE / DN 8 TO DN 150 CRBON STEEL / FULL BORE / DN 8 TO DN 150 Carbon steel, forged body full bore ball valve designed to international and European standards FETURES PPLICTIONS Saturated steam. mmonia, natural gas, propane

More information

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Multi-Point, Vertically-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the Multi-

More information

SERIES V. High Performance Segmented Ball Valve

SERIES V. High Performance Segmented Ball Valve SERIES V High Performance Segmented Ball Valve Publication SV000-101 Issue 02/17 Rev. D General Information High Rangeability: 300:1 Turn down ratio Flow Characteristic: Equal Percentage Low Pressure Recovery

More information

2 1 /2" Glycerin-Filled Dual Scale Vacuum Gauges

2 1 /2 Glycerin-Filled Dual Scale Vacuum Gauges BAC-25 Brass Case Dial Size: 2 1 /2" Glycerin Filled Pressure Ranges: 30" HG to 15,000 PSI/Bar (Dual Scale) Accuracy: Within 1.5% of Maximum Graduation Case: Forged Brass With Polished Brass ABS Bourdon

More information

C&K ET Series Sealed Subminiature Toggle Switches

C&K ET Series Sealed Subminiature Toggle Switches Models vailable Features/Benefits Sealed against solder and cleaning process contaminants ESD protection available Thru-hole and surface mount models Compact sizeand small footprint save PCB space Typical

More information

Liquid level switch Type AKS 38

Liquid level switch Type AKS 38 Data sheet Liquid level switch Type AKS 38 AKS 38 is an electro-mechanical liquid level switch designed to provide a reliable, electromechanical response to liquid level changes. The simple and basic design

More information

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS BSA 10 AC motor Stroke La =Lc + Stroke Lc Capacitor T Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth 17 Stroke end reed switches FCM

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

GVI Series Industrial Globe Valves for Flow Control

GVI Series Industrial Globe Valves for Flow Control Series Industrial Globe Valves for Flow Control 2-way Flow Control Globe Valves ssured utomations Series Industrial Globe Valves are contructed with rugged carbon steel or stainless steel bodies. They

More information

MB SERIES SMB SERIES MINIATURE TANK BREATHERS MINIATURE TANK BREATHERS ACCCESSORIES. Phone (608) Fax (608)

MB SERIES SMB SERIES MINIATURE TANK BREATHERS MINIATURE TANK BREATHERS ACCCESSORIES. Phone (608) Fax (608) G1 MB SERIES MINIATURE TANK BREATHERS 10 Micron Filtration (Nominal) Shatter Resistant Plastic Construction Temperatures Up to +225 F Model A B Number Thread Size Overall Height MB-02-10 1/4 NPT 1.8 MB-03-10

More information

MERCURY CONTACTORS & RELAYS

MERCURY CONTACTORS & RELAYS MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND

More information

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features D26.SWG.CAT.ENG0 D-26 Wastewater Combination Air Valve for Wastewater Description The D-26 Combination Air Valve combines an air & vacuum component and an air release component in a single body. The valve

More information

Behringer Ball Valve Ordering Code

Behringer Ball Valve Ordering Code Ball Valve Catalog Behringer Ball Valve Ordering Code 1 Behringer 2-Way Ball Valves Block Body Valves with Threaded Connections Size Range: 1/4-1 Steel Material Delrin Ball Seats (Others available on request)

More information

NOW UL LISTED. Patented

NOW UL LISTED. Patented NOW UL LISTED Patented Ø1.730 Ø 1.765 Ø.922 4.15 8.71 TOP VIEW 1.50 2" NPS THRDS. BOTTOM VIEW 2.13 2.14 SIDE VIEW 2.000 CLAY & BAILEY MFG. CO. 2" FILL SHUT OFF VALVE DATE:10/25/05 01228-03-2200 2" X 4"

More information

12AT/50AT Series Spin-On Filters

12AT/50AT Series Spin-On Filters 1 Applications for Mobile Equipment Hydrostatic Drives Industrial Power Units Reservoir Breathers Often, economic conditions dictate what type of filter is used on a piece of equipment. When costs are

More information

APG. LF - Miniature Liquid Level Sensors

APG. LF - Miniature Liquid Level Sensors LF - Miniature Liquid Level Sensors The LF Miniature Liquid Level sensors are designed for reliable operation in small tanks and containers. Their rugged design and multiple configurations make them the

More information

Stainless Steel Trim Standard. ir and Vacuum Sewer Valves permit a large volume of air to

Stainless Steel Trim Standard. ir and Vacuum Sewer Valves permit a large volume of air to ir and Vacuum Sewer Valves Valve Functio n Exhausts air as a pipeline fills, and allows air in as pipeline drains Features Include Standard and short body series available vailable in sizes thru 10 ll

More information

QSS: Quick Set System. Product Catalog Compression Sleeve Valves and Fittings to 15,000 psi (1034 bar)

QSS: Quick Set System. Product Catalog Compression Sleeve Valves and Fittings to 15,000 psi (1034 bar) QSS: Quick Set System Product Catalog Compression Sleeve Valves and Fittings to psi (1034 bar) Section Page Introduction.............................. 2 QS Needle Valves........................... 4 QS

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

9012G Pressure and 9016G Vacuum Switches

9012G Pressure and 9016G Vacuum Switches Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:

More information