L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
|
|
- Dylan Shaw
- 5 years ago
- Views:
Transcription
1 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Multi-Point, Vertically-Mounted Liquid Level Float Switch
2 READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the Multi- Point Liquid Level Float Switch. It is important that all instructions are read carefully and followed sequentially. Detailed instructions are included in the Complete Installation section of this manual. Conventions Used in this Manual Certain conventions are used in this manual to convey specific types of information. General technical material, support data and safety information are presented in narrative form. The following styles are used for notes, cautions and warnings: Notes Notes contain information that augments or clarifies an operating step. Notes do not normally contain actions and often follow the procedural steps to which they refer. Cautions Cautions alert the technician to special conditions that could injure personnel, damage equipment, or reduce a component s mechanical integrity. Cautions are also used to alert the technician of unsafe practices, the need for special protective equipment, or specific materials. In this manual, a caution indicates a potentially hazardous situation which, if not avoided, may result in minor to moderate injury. Notice of Copyright and Limitations Copyright 2015 Solutions With Innovation, LLC; All rights reserved. Solutions With Innovation reserves the right to make changes to the product described in this manual at any time without notice. Solutions With Innovation makes no warranty with respect to the accuracy of the information in this manual. Warranty All Solutions With Innovation Mechanical Level and Flow Controls are warranted free of defects in materials and workmanship for one full year from the date of the original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Solutions With Innovation will repair or replace the product at no cost to the purchaser (or owner) other than transportation. Solutions With Innovation shall not be liable for misapplication, labor claims, direct or consequential damage, or expenses arising from the installation or use of the equipment. There are no other warranties expressed or implied, except special written warranties covering specific Solutions With Innovation products. Quality Assurance The Quality Assurance System in place at Solutions With Innovation guarantees the highest level of quality throughout the company. Solutions With Innovation is committed to providing full customer satisfaction; both in quality products and in quality service. Contacts Phone: Mon-Fri, 9 AM - 5 PM EST Fax: for General Inquiries sales@innovativesensing.com 2 MULTI-POINT LIQUID LEVEL FLOAT SWITCH
3 TABLE OF CONTENTS LIQUID LEVEL FLOAT SWITCH Multi-Point, Vertically-Mounted 1.0 Installation 1.1 Unpacking Before You Begin Site Preparation Equipment and Tools Mounting Threaded Mounting Wiring Preventative Maintenance 2.1 What To Do Inspect Entire Unit Periodically Inspect Connections Monthly Keep Unit Clean What To Avoid Reference Information 3.1 Description Theory of Operation Troubleshooting External Causes Unit Causes Agency Approvals Specifications Physical Specifications Electrical Specifications Switch Wiring Codes Dimensional Specifications Model Configurator Notes...11 MULTI-POINT LIQUID LEVEL FLOAT SWITCH 3
4 1.0 COMPLETE INSTALLATION This section provides detailed procedures on properly installing the Multi-Point Liquid Level Float Switch. CAUTION! IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. CAUTION! THIS UNIT CONTAINS REED SWITCHES THAT MAY BE PERMANENTLY DAMAGED BY MECHANICAL SHOCK OR VIBRATION. AVOID DROPPING OR HITTING THE DEVICE AGAINST HARD SURFACES. 1.1 UNPACKING Unpack the instrument, carefully. Make sure that all components have been removed from the packing material. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours of receiving. Compare the contents with the packing slip and report any discrepancies to the factory immediately. Record the sales order number and/or serial number for future reference when ordering parts. Before Proceeding to Installation, Complete the Following: Inspect all components for damage. Report any damage to the carrier within 24 hours of receiving. Record the model and serial numbers for future reference when ordering parts. Model Number Serial Number 1.2 BEFORE YOU BEGIN CAUTION! DURING THE INSTALLATION OF THE MULTI-POINT LIQUID LEVEL SWITCH, THE FLOAT AREA MUST BE KEPT FREE OF METALLIC PARTICLES THAT MIGHT BE ATTRACTED TO THE FLOAT S INTERNAL MAGNET Site Preparation 1 Ensure that the length and the inside diameter of the mounting is sized correctly to accommodate the Multi-Point Liquid Level Float Switch Equipment and Tools No special equipment or tools are required to install the Multi-Point Liquid Level Float Switch. The Following Are Recommended: Wrenches, thread sealant, gaskets and/or bolting as required for the process connection. 4 MULTI-POINT LIQUID LEVEL FLOAT SWITCH
5 1.3 MOUNTING The Multi-Point Liquid Level Float Switch is available in a variety of threaded and flanged mountings. These devices are meant to be installed on the top or bottom of a process tank. They should be mounted in an area free of turbulence or direct streams. Contact the manufacturer for flanged mounting options Threaded Mounting How to Install an Multi-Point Liquid Level Float Switch: 1 Apply either Teflon tape or an appropriate thread sealant to the mounting threads to prevent galling. 2 Engage the thread by hand to avoid unnecessary damage. 3 Using a wrench, rotate the unit clockwise until the threads are tight within the mounting. 4 Ensure that the float(s) and stem are in a vertical orientation. Adjustable 1.4 WIRING CAUTION! OBSERVE ALL APPLICABLE ELECTRICAL CODES AND PROPER WIRING PROCEDURES. SPST Reed Switch: 1 Connect the wiring to the switch leads or terminals, as illustrated below. SPDT Reed Switch: 1 Connect the wiring to the proper switch leads or terminals, as illustrated below. NORMALLY-OPEN Dry Condition NORMALLY-CLOSED Dry Condition COMMON NORMALLY-OPEN NORMALLY-CLOSED Dry Condition COMMON ONE COMMON WIRE 1 to 5 Switch Points INDEPENDENT CIRCUITS 1 to 3 Switch Points ONE COMMON WIRE 1 or 2 Switch Points COMMON Contact Protection: In order to maintain the life and reliability of the internal reed switch, it is essential to provide protection when switching inductive loads. When the current breaks, the energy stored in the load generates a high frequency voltage across the switch contacts. If the voltage is large enough, it can initiate arcing and cause the contacts to weld together. Damage can ultimately be prevented by suppressing the voltage. Through the use of a diode for DC circuits and a resistor-capacitor network for AC circuits, contact protection will ensure reliable performance from the reed switch. MULTI-POINT LIQUID LEVEL FLOAT SWITCH 5
6 2.0 PREVENTATIVE MAINTENANCE Periodic inspections are necessary to maintain the proper functionality of the Multi-Point Liquid Level Switch. The switch is a safety device that protects the equipment it serves. A systematic program of preventative maintenance should be implemented at the time of installation. If the following instructions are completed routinely, the switch will provide continuous, reliable protection. 2.1 MAINTENANCE PROCEDURES Inspect Unit Periodically Verify that there are no cracks or chipped surfaces on the unit. Should the float or stem assembly become damaged, obtain a replacement immediately Inspect Connections Monthly Multi-Point Liquid Level Switches may be vulnerable to excessive heat and moisture. Under these conditions, the electrical wire insulation can periodically break or peel away. As a result, the bare wires may become exposed to the elements and incur damages. Inspect all wiring, carefully and replace any wires exhibiting signs of brittle insulation. Inspect all electrical connections to ensure tightness. Repair or replace any wiring, if necessary Keep Unit Clean Periodic cleanings of the float and stem assembly will ensure the continual, uninterrupted movement of the mechanism. Always keep the open area between the components clean and free of any potential interferences. Objects and debris may cause systematic interruptions and a loss in equipment functionality. 2.2 WHAT TO AVOID NEVER LEAVE THE SWITCH WIRING EXPOSED TO THE ELEMENTS. NEVER PLACE A JUMPER WIRE ACROSS THE TERMINALS TO CUT-OUT THE CONTROL. If a jumper is necessary for testing purposes, ensure that it is removed prior to placing the control into service. NEVER USE IN SYSTEMS CONTAINING IRON PARTICLES. The magnet within the float assembly can attract the particles and become jammed. 6 MULTI-POINT LIQUID LEVEL FLOAT SWITCH
7 3.0 REFERENCE INFORMATION This section illustrates an overview of the Multi-Point Liquid Level Switch, as well as information on troubleshooting common problems, agency approval listings, and detailed physical, functional and performance specifications. 3.1 DESCRIPTION The vertically-mounted Multi-Point Liquid Level Switch is designed to monitor up to five levels on a single device. With only one single entry, the can track changing levels within a small tank, as well as monitor liquid interfaces of dissimilar liquids for oil/water separations, chemical emulsions and condensation levels. Probe lengths are available up to 4 with over 360 possible combinations of floats, mounts and material options to suit every application. Additional options include a variety of enclosures as well as integrations with thermostatic switches to provide level and temperature sensing capabilities within one control. 3.2 THEORY OF OPERATION The switching action is achieved through the use of an internal magnet within the float assembly and its interaction with the switch mechanism. As the liquid level fluctuates inside the tank, the float moves. Its magnetic field actuates each reed switch inside the stem and completes an electrical circuit. Brass Stainless Steel Adjustable 3.3 TROUBLESHOOTING The Multi-Point Liquid Level Switch is designed and engineered for trouble-free operation over a wide range of operating conditions. Common problems are discussed in terms of their symptoms and recommended corrective actions External Causes An initial indication of improper operation is the failure of the controlled equipment to function (pumps will not start or stop, signal lamps fail to light, etc). If these symptoms occur, whether at the time of installation or during routine service thereafter, check for potential external causes first: Blown Fuses Tripped Reset Button(s) Open Power Switch Faulty Equipment Controlled By the Level Switch Defective Wiring to the Level Switch MULTI-POINT LIQUID LEVEL FLOAT SWITCH 7
8 3.3.2 Unit Causes If a thorough inspection of any external causes fails to locate the problem, proceed to an inspection of the unit, itself. DISCONNECT POWER TO THE LEVEL SWITCH BEFORE PROCEEDING. SYMPTOM PROBLEM SOLUTION THE UNIT IS UNRESPONSIVE. ELECTRICAL FAILURE. USE AN ELECTRICAL CONTINUITY CHECKER TO DETERMINE IF THE SWITCH IS FUNCTIONAL. IF THE SWITCH DOES NOT OPERATE PROPERLY WHEN ACTIVATED, THE ENTIRE LEVEL SWITCH MUST BE REPLACED. THE UNIT DOES NOT ACTIVATE WHEN THE FLOAT CHANGES POSITION. THE UNIT IS JAMMED. REMOVE THE LEVEL SWITCH FROM SERVICE. CHECK THE FLOAT ASSEMBLY FOR OBSTRUCTIONS OR ACCUMULATION OF PARTICLES WHICH MAY CAUSE BINDING. IF BINDING IS PRESENT IN THE FLOAT ASSEMBLY AND CANNOT BE CLEARED BY NORMAL CLEANING PROCEDURES, THE ENTIRE CONTROL MUST BE REPLACED. THE UNIT ONLY FUNCTIONS WHEN IT IS NOT IN SERVICE. LIQUID IS NOT ENTERING THE VESSEL. CHECK TO ENSURE THAT LIQUID IS ENTERING THE TANK OR VESSEL. A CLOSED VALVE OR CLOGGED PIPELINE MAY PREVENT MOVEMENT OF THE LIQUID IN THE VESSEL. THE UNIT ONLY FUNCTIONS WHEN IT IS NOT IN SERVICE. THE TANK LEVEL IS NOT HIGH ENOUGH TO HAVE THE FLOAT FUNCTION. CHECK THE FLOAT TO MAKE SURE IT IS BUOYANT IN THE LIQUID. THE TANK OR VESSEL MUST HAVE AN ADEQUATE LIQUID LEVEL. THE FLOAT IS NOT BUOYANT. THE FLOAT IS COLLAPSED AND/OR FILLED WITH LIQUID. CHECK THE FLOAT FOR RUPTURES, DEFORMATION, AND ANY LIQUID TRAPPED INSIDE THE ASSEMBLY. IF THE FLOAT IS FILLED WITH LIQUID OR HAS COLLAPSED, THE ENTIRE LEVEL SWITCH MUST BE REPLACED. DO NOT ATTEMPT TO REPAIR THE FLOAT. ALL COMPONENTS WITHIN THE LEVEL SWITCH ARE IN WORKING ORDER, BUT THE UNIT STILL DOES NOT FUNCTION. AN EXTERNAL PROBLEM. REPEAT AN INSPECTION OF THE EXTERNAL CONDITIONS AS DESCRIBED IN SECTION If you are still in doubt about the condition or performance of your control, consult the factory for further instructions. 8 MULTI-POINT LIQUID LEVEL FLOAT SWITCH
9 3.4 AGENCY APPROVALS AGENCY APPROVED MODEL(S) FILE NUMBER AREA CLASSIFICATION UL E RECOGNIZED UNDER UL508 MOTOR CONTROLLERS & NJ0T8 MOTOR CONTROLLERS 3.5 SPECIFICATIONS Physical Specifications FLOAT MATERIAL DIMENSIONS TEMPERATURE PRESSURE MIN. SPECIFIC GRAVITY Polypropylene (Hollow) 1 x 1-40 to +150 F 50 PSIG 0.66 Polypropylene (Solid) 1 x 1-40 to +150 F 150 PSIG 0.87 PVC 1 x 1-40 to +140 F 50 PSIG Stainless Steel 1 x 1-40 to +300 F 300 PSIG Stainless Steel 1.50 x 1-40 to +300 F 100 PSIG Stainless Steel 1 Ball -40 to +300 F 375 PSIG Stainless Steel 0.90 x to +300 F 200 PSIG 0.96 Teflon (PFA) 1 x 1-40 to +300 F 1000 PSIG 0.60 Teflon (Hollow) x to +212 F 25 PSIG 0.94 Buna-N 1 x 1-40 to +180 F 150 PSIG 0.63 Polysulfone (Hollow) 1 x 1-40 to +250 F 50 PSIG 0.94 Nylon 1 x 1-40 to +212 F 50 PSIG Electrical Specifications SIGNAL OUTPUT TYPE OF CONTACTS TYPE OF SWITCHES SWITCH RATING Switch Closure SPST, SPDT Hermetically-Sealed Reed Switch 20 VA, 240 VAC/VDC Max. SPST 50 VA, 240 VAC/VDC Max. SPST 100 VA, 240 VAC/VDC Max. SPST 3 VA, 30 VAC/VDC Max. SPDT Switch Wiring Codes WIRING OPTIONS GROUP 1 SPST GROUP 2 SPST GROUP 3 SPDT Common Wire Black None Black (Levels) N.O. or N.C. N.O. or N.C. N.O. & N.C. L1 Red Red/Red Red/White-Red L2 Yellow Yellow/Yellow Yellow/White-Yellow L3 Blue Blue/Blue L4 L5 Brown Orange 1 All SPST switches are set to normally-open operation in their dry, no level condition unless specified otherwise. White-Red and White-Yellow denote single white wire with red or yellow stripes. 2 Each switching point requires one float. For special applications, a single float can be used to activate two switch points, though these points must have a minimum separation of 1/8 (3 mm). The maximum number of actuation levels depends on the wiring type selected. 3 Standard Lead Wires are 24 long, 22 AWG, ULapproved wire. MULTI-POINT LIQUID LEVEL FLOAT SWITCH 9
10 3.5.4 Dimensional Specifications Actuation Level Dimensions L4 FLOAT TYPE A B C D 1 x ¾ 1 ⅛ 1.5 x ¾ 1 ⅛ 1 Ball 1 1 ¾ 1 ⅛ 0.9 x ½ 1 ½ ⅛ L3 L2 L1 L0 A B L4 L3 L2 L1 A Area Definitions DEFINITION A B C Minimum Distance from Actuation Point to Inside Surface of Tank or Mounting Pad Minimum Distance Between Actuation Levels Minimum Distance from End of Unit to Lowest Actuation Level L0 B D Minimum Distance Between Points When A Single Float is Used to Activate 2 Switches* D D Notes 1 A, B and C dimensions are based on a specific gravity of 1.0. Ø 5 16 C Ø 5 16 C 2 When using one float for two actuation points, contact the factory for the available switch ratings. 3 Actuation levels are calibrated on descending fluid levels with water as the fluid, unless otherwise specified. Adjustable 4 Standard tolerance on actuation levels is ± ⅛ (3 mm). 3.6 MODEL CONFIGURATOR TECHNOLOGY MODEL CONFIG. MOUNT STEM FLOAT ELECTRICAL ENCLOSURE L Liquid Level Sensor 312 5/16 Stem - Standard 00 No Mount 01 Brass 02 Polypropylene (H) VA SPST 0 No Enclosure A Adjustable 01 ⅛ NPT 02 Polypropylene 03 Polypropylene (S) VA SPST 1 Polypropylene NEMA 4 C Custom 02 ¼ NPT 05 PVC 05 PVC (Hollow) 06 3 VA SPDT 2 Aluminum NEMA 4/7/9 03 ⅜ NPT S.S S.S VA SPST 3 Cast Iron NEMA 4/7/9 04 ½ NPT 15 Teflon (PFA) 15 Teflon (PFA) 05 ¾ NPT 22 Polysulfone 16 Teflon PTFE (H) 06 1 NPT 18 Nylon 07 1 ¼ NPT 20 Buna-N 08 1 ½ NPT 22 Polysulfone (H) 09 2 NPT L MULTI-POINT LIQUID LEVEL FLOAT SWITCH
11 3.7 NOTES MULTI-POINT LIQUID LEVEL FLOAT SWITCH 11
12 ASSURED QUALITY & SERVICE COST LESS Service Policy Owners of Solutions With Innovation products may request a return of the product, or any part of the product for complete rebuilding or replacement. Units will be rebuilt or replaced promptly. Products returned under the SWI Service Policy must be returned by prepaid transportation. Solutions With Innovation will repair or replace the product at no cost to the purchaser (or owner) other than transportation if: 1 Returned within the warranty period; and 2 Factory Inspection finds the cause of the claim to be covered under the warranty. If the problem is due to circumstances beyond Solutions With Innovation s liability, or is NOT covered by the warranty, there will be charges for labor in addition to the parts required to rebuild or replace the equipment. In rare cases, it may be expedient to ship replacement parts; or in extreme cases, an entire product before the damaged product is returned. If a quick replacement service is necessary, notify the manufacturer of the damaged product s model and serial number. In such cases, credit for the returned materials will be determined on the applicability of the warranty. Return Material Procedure In order to efficiently process any returned materials, it is essential that a Return Material Authorization (RMA) number be obtained from the manufacturer prior to an item s return. RMA s can be issued through local representatives, or by contacting the factory directly. Please supply the following information: 1 The Company s Name 2 Description of the Material 3 Product Serial Number 4 Reason for Return 5 Product s Application Used units must be properly cleaned in accordance with OSHA standards before it is returned to the manufacturer. A Material Safety Data Sheet (MSDS) must accompany units or materials that were used in any type of media. All return shipments to the factory must be by done via prepaid transportation. All product replacements will be shipped F.O.B. manufacturer. No claims for misapplication, labor, direct or consequential damage will be allowed. BULLETIN: IS EFFECTIVE: 1/15
L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
L007 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Side-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L007 Side- Mounted
More informationL-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
L-Series: L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 AND L195 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single-Point, Vertically-Mounted Liquid Level Float Switch L001
More informationS003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
S003 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information
More informationL500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL
L500 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information
More informationFor Hazardous Locations
L500E LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch For Hazardous Locations READ THIS MANUAL PRIOR TO INSTALLATION This
More informationLIQUID LEVEL FLOAT SWITCH. F7 Series INSTALLATION AND OPERATIONS MANUAL. Single-Point, Vertically-Mounted Liquid Level Float Switch
F7 Series LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single-Point, Vertically-Mounted Liquid Level Float Switch F7 Series LIQUID LEVEL FLOAT SWITCH Single-Point, Vertical Mount 1.0 Installation
More informationL070 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL. For Industrial Use
L070 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Side-Mounted Liquid Level Float Switch For Industrial Use READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the
More informationFor CRN Installations
L072 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Side-Mounted Liquid Level Float Switch With Manual Reset For CRN Installations READ THIS MANUAL PRIOR TO INSTALLATION This manual provides
More informationU00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004
U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual
More informationU00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004
U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual
More informationTuffy Liquid Level Controls with Pneumatic Switch
Tuffy Liquid Level Controls with Pneumatic Switch Installation and Operating Manual Side Mounted Float Level Switch Read this Manual Before Installing This manual provides information on the Tuffy Liquid
More informationInstallation and Operating Manual
Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing
More informationSeries K Pneumatic Switch Mechanism
Series K Pneumatic Switch Mechanism Installation and Operating Manual Non-Bleed Switch For Liquid Level Switches Read this Manual Before Installing This manual provides information on the Series K Pneumatic
More informationJ52 Refrigerant Level Switches
J2 Refrigerant Level Switches Instruction Manual and Parts List OPERATING PRINCIPLE Figures 1 and 2 illustrate the simple and foolproof Magnetrol operating principle. Switching action is obtained through
More informationTuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual
Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual Side Mounted Float Level Switch Read this Manual Before Installing This manual provides information on the Tuffy
More informationAV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual
Switch-Tek Horizontal, Vertical & Float-Point Float Switches AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA
More informationSwitch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A
Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015
More informationM-100 Adjustable flow switch with right-angle flow
M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification
More informationElectric Actuator Installation, Operation & Maintenance Manual
ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:
More informationLevalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016
Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Levalarm Gold STORAGE AND HANDLING The Reliance Levalarm Gold meets or exceeds all applicable specifications when shipped from
More informationInstructions for Installing and Operating Clark Reliance EA100 Series Levalarm
Section: R500.532F Bulletin: 532F Date: 7/1/2015 Supersedes: 532E Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm This manual covers the following model numbers: EA100D,
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI)Full Body Swing Check Valves. To ensure efficient and safe
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation
More informationNEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH
NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev
More informationSeries K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual
Series K Installation and Operating Manual Pneumatic switch mechanism and housings UNPACKING Unpack the instrument carefully. Make sure all components have been removed from the foam protection. Inspect
More informationKOBOLD SV FLOWMETER/SWITCH. User Instructions
KOBOLD SV FLOWMETER/SWITCH User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com R2_4-13 SV Table Of Contents
More informationINSTALLATION / INSTRUCTION MANUAL
SOLITEL Vibrating rod level switches for solids INSTALLATION / INSTRUCTION MANUAL DESCRIPTION The Solitel vibrating rods are used for high or low level detection on powders and granulars with a minimum
More informationCOMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL Model Number: Service: Serial Number: Installation Date: Installation Location / Application: PLEASE RECORD THE FOLLOWING DATA (Information is
More informationNor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves
Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your DeZURIK Actuator. All safety messages in the instructions
More informationKOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04
KOBOLD VKA FLOWMETER/SWITCH User Instructions Manual-VKA_03-04 VKA Table of Contents 1.0 General............................................. 1 Specifications..........................................
More informationTuffy Liquid Level Switches
Tuffy Liquid Level es Tuffy liquid level switches are designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. Models are equipped with a single electric or pneumatic
More informationMcCANNA Actuation Systems B
17710-B Ramcon Series 8/25 C/CR, 50/100 B/BR, 250/500 B/BR Electric Actuators Installation, Operation and Maintenance Instructions Contents Storage...........................................................................................................
More informationGeneral Installation Instructions for Valves and Gates
General Installation Instructions for Valves and Gates Thank you for your purchase of a Lorenz valve. We appreciate your business! Please read this installation manual and follow recommended safety precautions.
More informationSwitch Pro w/ Compact Junction Box A_1_ Series Owner s Manual
Warranty, Service & Repair To register your product with the manufacturer, go to the Flowline website for on-line registration. The website address is as follows: www.flowline.com On-line Warranty Registration
More informationA1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction
A186-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED Introduction The MAXIGARD A1500
More informationCOOKSON OWNER'S MANUAL
COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8
More informationModel B73 & Series 75
Model B73 & Series 75 Installation and Operating Manual Sealed External Cage Liquid Level Switches Read this Manual Before Installing This manual provides information on the B73 and Series 75 Liquid Level
More informationKOBOLD DF-WM Flow Monitor. User Instructions
KOBOLD DF-WM Flow Monitor User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-DF-WM_12-13 DF-WM Table
More informationDisplacer Type. Installation and Operating Manual. Liquid Level and Proof-er Switches
isplacer Type Installation and Operating Manual Liquid Level and Proof-er es Read this Manual Before Installing This manual provides information on the xternal Cage isplacer Liquid Level. It is important
More informationMA-5200 Series MA-5300 Series
MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require
More informationINTRODUCTION INSTALLATION
INTRODUCTION INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS This instruction manual includes installation, operation and maintenance information for the figure G73 gear operator. The figure G73 is
More informationAdjustable Purge Valve
U S E R G U I D E UGC031-0508 www.conairgroup.com Adjustable Purge Valve Single and Dual APV Models Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l Parts and Service:
More informationVP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY
Issue 5 24/48 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-4124 and VP-4124-E, 24/48 Volt Power Supplies.
More informationInstallation, Operation, and Maintenance Manual
Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2
More information100 Series Flow Switches Technical Reference Manual
Proteus Industries Inc. 100 Series Flow Switches Technical Reference Manual Can we Improve? Tell our President! Can we improve our product, our support or this manual? We are committed to continuous improvement
More informationModel FM1000 Series Operating Instructions. Drum Pump Flow Meter
Model FM1000 Series Operating Instructions Drum Pump Flow Meter Table of Contents Safety... 1 Introduction... 1 Specificatons... 1 Features... 1 Section 1 - Installation... 2 Section 2 - Operation... 2
More informationSwing-Flex Check Valve
Manual No. SFCV-OM1-11 Swing-Flex Check Valve Operation, Maintenance and Installation Manual INTRODUCTION 1 RECEIVING AND STORAGE 1 DESCRIPTION OF OPERATION 1 INSTALLATION 2 VALVE CONSTRUCTION 2 MAINTENANCE
More informationSwing-Flex Check Valve
Manual No. SFCV-OM1-14 Swing-Flex Check Valve Operation, Maintenance and Installation Manual INTRODUCTION.. 1 RECEIVING AND STORAGE. 1 DESCRIPTION OF OPERATION.. 1 INSTALLATION 2 VALVE CONSTRUCTION.. 2
More informationGLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation
More informationManual Transfer Switch
Manual Transfer Switch Instruction Manual 30 1200 Amp 2, 3 & 4 Pole Page 1 WARNING Before Installation READ THIS MANUAL carefully to learn how to properly install, operate and maintain this unit. Personal
More informationSPC-PANEL Simplex, Single Phase Pump Control Panel
Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner
More informationCIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT
GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS
More informationKOBOLD DF-MA Flow Transmitter. User Instructions
KOBOLD DF-MA Flow Transmitter User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-DF-MA_12-13 DF-MA Table
More informationNECO Pumping Systems
INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND
More informationVP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY
Issue 6 VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-6124 and VP-6124-E, 24Volt Power
More informationICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator
ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator 6810 Powerline Dr. Florence, Ky. 41042 Telephone 859-727-7890, Tool free 800-662-9424, Fax. 859-727-7-4070,
More informationM-50/55 Series. Fixed setting flow switch with in-line flow
M-50/55 Series Fixed setting flow switch with in-line flow Features Very accurate custom flow settings For corrosive and non-corrosive liquids or gases All-Teflon switch available Senses increasing or
More informationAir Curtain. Installation, Operating and Maintenance Instructions
Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE
More informationSafe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual
Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for
More informationModel F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Technical Services: Tel: () 31-931 / Fax: () 791-55 Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and
More informationCIRCLE SEAL CONTROLS
CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions
More informationFIXED DEPTH INSERTION METER INSTRUCTIONS
UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken
More informationINSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD
INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE B-3724M ACTUATOR MANIFOLD MIDLAND MANUFACTURING CORP. 7733 Gross Point Road Skokie, Illinois 60077 Phone (847) 677-0333 FAX (847) 677-0138 WEBSITE
More informationTABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.
1. PARTS A. Injector B. Ceramic Weight. C. Plastic tubing 8' long with foot strainer. 2. INSTALLATION The injector may be installed in any position in the water line with the arrow in the direction of
More informationC3000 SIGNAL TRANSMITTER. Introduction
C131-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 C3000 SIGNAL TRANSMITTER Introduction The MAXIGARD C3000 series is designed to convert shaft
More informationNEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL
NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry
More informationINSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'
INSTRUCTION BOOK FOR Cosmopolitan Electrol For Sizes To 9' x 12' Important Safety Instructions When using your video equipment, basic safety precautions should always be followed, including the following:
More informationDome-Loaded Pressure Reducing BD-Series
Dome-Loaded Pressure Reducing BD-Series *Parts will differ for high pressure valves. Load Piston - Piston - U-cup U-cup Piston 1. Carefully place the u-cup over the neck of the piston. Load Cylinder -
More informationVSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL
VSI SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES VSI, LLC. 2-0 SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL Publication: V2100- August 2016 TABLE OF CONTENTS
More informationMotorized Stainless 2-Way Valves
Installation and Operation Manual Motorized Stainless 2-Way Valves Safety Valve ETV Applications WARNING This Heat-Timer valve is strictly an operating valve; it should never be used as a primary limit
More informationBULLETIN NO.ELEC IM121/10A Replaces IM121/09A
Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt
More informationAPM Pneumatic Control for Boiler Feed System Applications
APM Pneumatic Control for Boiler Feed System Applications Installation and Operating Manual Pneumatic Control Read this Manual Before Installing This manual provides information on the APM Pneumatic Control
More informationSEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14
SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?
More informationVal-Matic Extended Bonnet Assembly Instructions
Manual No. EBAI-OM-2 Val-Matic Extended Bonnet Assembly Instructions Operation, Maintenance and Installation Manual DESCRIPTION OF ASSEMBLY... 1 INSTALLATION INSTRUCTIONS... 1 TROUBLESHOOTING... 1 PARTS
More informationCT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL
CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation
More informationOwner's/Installation Manual
Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH
More informationHand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )
Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 ) Bulletin No. 82-00A Suitable For: Ammonia, Fluorocarbons, Nitrogen and Carbon Dioxide Features ASTM 352 LCB Cast Steel
More informationIMPORTANT SAFETY INSTRUCTIONS
OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
More informationp.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.
p.t.o. Slip clutch 65517 Installation Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read
More informationLEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.
LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL www.enoscientific.com Eno Scientific PO Box 1586 Hillsborough, NC 27278 USA www.enoscientific.com 910-778-2660 Copyright Notice Copyright 2015 Eno
More informationManual Concentrate Management System
Form 887 05/15 Manual Concentrate Management System with Automatic Flush INSTALLATION AND OPERATION MANUAL Unit Serial Number All quality FoamPro products are ruggedly designed, accurately machined, carefully
More informationRENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev
Manual Part #: M-3022 Feeder AF371 Operations Rev. 3-16-04 1 RENA AF371 Feeder YOUR RENA AF371 IS DISTRIBUTED BY RENA SYSTEMS INC. SERVICE AND SUPPORT FOR THIS PRODUCT IS PROVIDED BY YOUR RENA DEALER.
More informationWastewater Combination Air Valve. Operation, Maintenance and Installation Manual
Manual No. WCAV-OM1-1 Wastewater Combination Air Valve Operation, Maintenance and Installation Manual INTRODUCTION... 2 RECEIVING AND STORAGE... 2 DESCRIPTION OF OPERATION... 2 INSTALLATION... 3 VALVE
More informationA5000GEC-24VDC ZERO SPEED SWITCH
A208-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 A5000GEC-24VDC ZERO SPEED SWITCH Introduction The MAXIGARD A5000GEC-24VDC is a zero speed switch
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationDisplacer Type. Installation and Operating Manual. Liquid Level and Proof-er Switches
isplacer Type Installation and Operating Manual Liquid Level and Proof-er es UNPAKIN Top mounting displacer units are shipped from the factory with the displacer and cable assembly removed from the head
More informationMAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators
MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return
More informationVal-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...
More informationVal-Matic 1-4 Combination Air Valve (Single Housing Type)
Manual No. ARCO-OM1-3 Val-Matic 1-4 Combination Air Valve (Single Housing Type) Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1
More informationVSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500
VSI INDUSTRIAL BALL BUTTERFLY VALVES VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500 INSTALLATION, OPERATION AND MAINTENANCE MANUAL
More informationLow Profile Wrenches Operation and Maintenance Manual
Low Profile Wrenches Operation and Maintenance Manual http://www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install and remove large bolts that have minimal
More informationA48 / A48B (base plate) BATTERY CHARGER
A48 / A48B (base plate) BATTERY CHARGER CPN41054 ISSUE DATE: 12315-8/98 ECN/DATE 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847) 299-1188 FAX: (847)299-3061 15349-07-07/02 16041 6/03 14575-2/01 INSTRUCTION
More informationTechnical Manual. DLM Module. This manual should remain with the unit.
Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this
More informationPositive Displacement Pump
www.conairgroup.com U S E R G U I D E UGC028-1105 Positive Displacement Pump Models PD 3. 5, 7.5, 10, 15 and 25 Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l
More information10 S e r i e s PRESSURE SWITCH. features
10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height
More informationRadian Research, Inc. makes no warranty on the accuracy of the information contained in this Operations Manual and accepts no liability for its use.
About This Operations Manual makes no warranty on the accuracy of the information contained in this Operations Manual and accepts no liability for its use. The information contained in this Operations
More informationSeries V. Electric. switch mechanisms. and housings. Installation and Operating Manual
Series V Installation and Operating Manual Electric switch mechanisms and housings UNPACKING Unpack the instrument carefully. Make sure all components have been removed from the foam protection. Inspect
More informationSpecification for Remanufacture Alstom Model 5 Switch Machine
Alstom Model 5 Switch Machine This page is intentionally left blank for the purpose of double sided printing Alstom Model 5 Switch Machine - Page 2 of 9 - (262) 658-3590 TABLE OF CONTENTS 1 SCOPE AND INTENT.5
More informationOFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES
OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES 1.INSTRUMENT DESCRIPTION Flow switches PL series are designed to be mounted in an upright position along horizontal pipes. These
More informationPressurized Bead Filters
Pressurized Bead Filters Installation Instructions Table of Contents Safety Information Installation Assembly Start Up Maintenance Troubleshooting Warranty Safety Information: 1. Installation should be
More information