CTR* /103 ED HYDRAULIC POWER PACKS TANK CAPACITY PUMP FLOW RATE SERIES 30. from 8 lt to 150 lt. from 1,6 lt to 77 lt ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈

Size: px
Start display at page:

Download "CTR* /103 ED HYDRAULIC POWER PACKS TANK CAPACITY PUMP FLOW RATE SERIES 30. from 8 lt to 150 lt. from 1,6 lt to 77 lt ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈"

Transcription

1 96 000/103 ED CTR HYDRAULIC POWER PACKS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 77 lt DESCRIPTION STANDARD COMPONENTS The CTR power packs, are realised with a soaked gear pump and a vertically mounted electric motor. The tank cover can be rotated of 180 without deplacing the installed components. The standard components are the intake filtre, the gear pump, the motor - pump connection group, the arrangement for the electric motor, the pressure relief valve, a position for electrovalve (not included in the supplying) the manometer with the shut-off cock, the oil charge cover and the oil visual indicator. The electric motor supplied is a 4-poles asyncronmotor with shape B5-V1 according to UNEL-MEC (versions with 2 and 6 poles are also available). It is possible to supply mono-phase and DC electric motor under request. The CTR 3-4 have the restraint edge. The available paintings are dull black RAL 9005 (standard), Grey RAL 7037 and Green RAL The power packs works with mineral oil (not included in the supplying). For the functioning with other hydraulic fluids, please consult our Technical Department. OPTIONAL COMPONENTS ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ Electric motor Manometer with shut-off selector Pressure relief valve Charge cover Level indicator Tank Intake filtre Gear pump Motor - pump connection group The standard power pack can be equipped with the following components: CTR other settings for electro-valves CETOP 03 with P2D modular subplates - return filtre for line mounting - other colour paintings under request CTR a double pump - high pressure pumps H version - other settings for electro-valves CETOP 03 and CETOP 05 with P2D or P4D modular subplates. - a return filter for line mounting - an heat exchanger air/oil or water/oil - oder colour paintings under request HYDRAULIC SIMBOL The standard power pack is delivered without the functional diagramm /103 ED 1/12

2 CTR IDENTIFICATION CODE FOR CTR0 POWER PACK C T R / / 1P - / / Power pack with soaked pump Cover size Tank capacity 8 dm 3 Electric motor shape B5 P = arrangement for motor mounting M = electric motor already mounted 4 poles electric motor power: 0.25 = 0.25 Kw 0.37 = 0.37 Kw Electric motor voltage (omit for P version) A = V / 50Hz V/60Hz Pump 1P type (see cat for the pump technical characteristics) Series No. (from 30 to 39 sizes and mounting dimensions remain unchanged) N = Dull black RAL 9005 (standard) G= Grey RAL 7037 V = Green RAL = without thermostat 1 = with thermostat 0 = without level controller 1 = with level controller Standard pannel with 3/8 rear A = P2D-M with 1 pos. Cetop 03 B = P2T-M with 2 pos. Cetop 03 Pump flow rate (l/min) at 1500 rpm (see flow rate / pressure table) FLOW RATE / PRESSURE TABLE Electric motor flange size Ø = 160 Electric motor power [kw] CTR0 Pump type Flow rate at 1500 rpm 0,25 0,37 [lt/min] Max. pressure [bar] 008 1P 1,6 R 1, pumps already available in our warehouse 2 R 2, ,5 R 2, ,3 R 3, ,2 R 3, R 4, ,8 R 5,5-35 6,7 R 6,3-30 7,5 R 7, /103 ED 2/12

3 CTR OVERALL AND MOUNTING DIMENSIONS FOR CTR /103 ED 3/12

4 CTR IDENTIFICATION CODE FOR CTR1 POWER PACK C T R 1 - Power pack with soaked pump Cover size Tank capacity 013 = 13 dm = 20 dm 3 Electric motor shape B5 P = arrangement for motor mounting M = electric motor already mounted / / 1P - / / Series No. (from 30 to 39 sizes and mounting dimensions remain unchanged) N = Dull black RAL 9005 (standard) G= Grey RAL 7037 V = Green RAL = without thermostat 1 = with thermostat 4 poles electric motor power: 0.55 = 0.55 Kw 0.75 = 0.75 Kw 1.1 = 1.1 Kw 1.5 = 1.5 Kw Electric motor voltage (omit for P version) A = V / 50Hz V/60Hz Pump 1P type (see cat for the pump technical characteristics) 0 = without level controller 1 = with level controller Standard pannel with 3/8 rear A = P2D-M with 1 pos. Cetop 03 B = P2T-M with 2 pos. Cetop 03 Pump flow rate (l/min) at 1500 rpm (see flow rate / pressure table) FLOW RATE / PRESSURE TABLE Electric motor flange size Ø = 200 Electric motor power [kw] CTR1 Pump type Flow rate at 1500 rpm 0,55 0,75 1 1,5 [lt/min] Max. pressure [bar] P 1,6 R 1, R 2, ,5 R 2, ,3 R 3, ,2 R 3, R 4, ,8 R 5, ,7 R 6, ,5 R 7, ,2 R 8, ,5 R 11, pumps already available in our warehouse /103 ED 4/12

5 CTR OVERALL AND MOUNTING DIMENSIONS FOR CTR H H2 (max) /103 ED 5/12

6 CTR IDENTIFICATION CODE FOR CTR2 POWER PACK C T R / / 1P - / / Power pack with soaked pump Cover size Tank capacity 25 dm 3 Electric motor shape B5 P = arrangement for motor mounting M = electric motor already mounted 4 poles electric motor power: 0.55 = 0.55 Kw 0.75 = 0.75 Kw 1.1 = 1.1 Kw 1.5 = 1.5 Kw Electric motor voltage (omit for P version) A = V / 50Hz V/60Hz Pump 1P type (see cat for the pump technical characteristics) Series No. (from 30 to 39 sizes and mounting dimensions remain unchanged) N = Dull black RAL 9005 (standard) G= Grey RAL 7037 V = Green RAL = without thermostat 1 = with thermostat 0 = without level controller 1 = with level controller Standard pannel with 3/8 rear A = P2D-M with 1 sett. Cetop 03 B = P2T-M with 2 sett. Cetop 03 Pump flow rate (l/min) at 1500 rpm (see flow rate / pressure table) FLOW RATE / PRESSURE TABLE Electric motor flange size Ø = 200 Electric motor power [kw] CTR2 Pump type Flow rate at 1500 rpm 0,55 0,75 1 1,5 [lt/min] Max pressure [bar] 025 1P 1,6 R 1, R 2, ,5 R 2, ,3 R 3, ,2 R 3, R 4, ,8 R 5, ,7 R 6, ,5 R 7, ,2 R 8, ,5 R 11, pumps already available in our warehouse /103 ED 6/12

7 CTR OVERALL AND MOUNTING DIMENSIONS FOR CTR /103 ED 7/12

8 CTR IDENTIFICATION CODE FOR CTR3 POWER PACK C T R 3 - / / - / / Power pack with soaked pump Cover size Tank capacity 035 = 35 dm = 50 dm = 75 dm 3 Electric motor shape B5 P = arrangement for motor mounting M = electric motor already mounted 4 poles electric motor power: 2.2 = 2.2 Kw 3 = 3 Kw 4 = 4 Kw 5.5 = 5.5 Kw 7.5 = 7.5 Kw Electric motor voltage (omit for P version) A = V / 50Hz V/60Hz Pump type : GP1 (see cat for the pump technical characteristics) GP2 Pump flow rate (l/min) at 1500 rpm (see flow rate / pressure table) Series No. (from 30 to 39 sizes and mounting dimensions remain unchanged) N = Dull black RAL 9005 (standard) G= Grey RAL 7037 V = Green RAL = without thermostat 1 = with thermostat 0 = without level controller 1 = with level controller Standard pannel with 3/8 rear A = P2D-M with 1 pos. Cetop 03 B = P2T-M with 2 pos. Cetop 03 P2XM multi positions mainfold. Cetop 03 to use with pumps GP2 (G 1/2 rear ) C2 = 2 mounting positions C4 = 4 mounting positions C6 = 6 mounting positions Standard pannel with G 1/2 side D = P4D-M with 1 pos. Cetop FLOW RATE / PRESSURE TABLE Electric motor flange size Ø = 250 Ø = 300 Flow rate at Electric motor power [kw] CTR3 Pump type 1500 rpm 2, ,5 7,5 [lt/min] Max. pressure [bar] GP GP pumps already available in our warehouse /103 ED 8/12

9 CTR OVERALL AND MOUNTING DIMENSIONS FOR CTR H H2 (max) /103 ED 9/12

10 CTR IDENTIFICATION CODE FOR CTR4 POWER PACK C T R 4 - / / - / Power pack with soaked pump Cover size Tank capacity 100 = 100 dm = 120 dm = 150 dm 3 Electric motor shape B5 P = arrangement for motor mounting M = electric motor already mounted 4 poles electric motor power: 5.5 = = = = 15 Electric motor voltage (omit for P version) A = V / 50Hz V/60Hz Pump type : GP2 (see cat for the pump technical characteristics) GP3 Pump flow rate (l/min) at 1500 rpm (see flow rate / pressure table) Series No. (from 30 to 39 sizes and mounting dimensions remain unchanged) N = Dull black RAL 9005 (standard) G= Grey RAL 7037 V = Green RAL = without thermostat 1 = with thermostat 0 = without level controller 1 = with level controller Standard pannel with 3/8 rear A = P2D-M with 1 pos. Cetop 03 B = P2T-M with 2 pos. Cetop 03 P2XM multi positions mainfold. Cetop 03 to use with pumps GP2 (G 1/2 rear ) C2 = 2 mounting positions C4 = 4 mounting positions C6 = 6 mounting positions Standard pannel with G 1/2 side D = P4D-M with 1 pos. Cetop FLOW RATE / PRESSURE TABLE Electric motor flange size Ø = 300 Ø = 350 Electric motor power [kw] CTR4 Pump type Flow rate at 1500 rpm 5,5 7, [lt/min] Max. pressure [bar] GP pumps already available in our warehouse GP /103 ED 10/12

11 CTR OVERALL AND MOUNTING DIMENSIONS FOR CTR4-P2 PORTS H H2 (max) OVERALL AND MOUNTING DIMENSIONS FOR CTR4-P H H2 (max) /103 ED 11/12

12 CTR 6 - ACCESSORIES LEVEL CONTROLLER LV/E1-127-M12-SC cod Maximum pressure bar 1 Working temperature C -20 / +70 Transparent tube material / Nylon + glass 35% Seals material / NBR Reed in exchange / 1A, 20W, 20VA, 200V BOLTS M12 ELECTRIC DIAGRAM (WITH FLUID) ELECTRIC DIAGRAM (WITHOUT FLUID) CONNCTOR CE DIN IP65 PG7 FLOAT MINIMUM LEVEL THERMOSTAT TC2 cod External sensor temperature range C 0/90 Degree of protection / IP40 Contacts A 10 Max. voltage V AC 250 Max. working temperature C 50 Cable guide / PG9 Housing material / Plastic Contacts material / Silver Capillary material / Copper Pocket material / Brass Mass Kg 0.3 DUPLOMATIC OLEODINAMICA SpA LEGNANO (MI) - P.le Bozzi, 1 / Via Edison Tel. 0331/ Fax 0331/ /103 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS. 12/12

CTR* /108 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41lt

CTR* /108 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41lt 96 000/108 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted

More information

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL 96 000/117 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41 lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted

More information

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min 52 000/103 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41 83 250/198 ED D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP 05 p max 250 bar Q max (see performance ratings table) MOUNTING INTERFACE OPERATING

More information

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25 41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7

More information

Q max (see specifications table)

Q max (see specifications table) 41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications

More information

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar /7 ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60 41 300/198 ED D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 0 ALTERNATING CURRENT - SERIES 60 CETOP 0 p max 30 bar Q max 100 l/min MOUNTING INTERFACE DIRECT-ACTING SOLENOID OPERATED

More information

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES 41 230/102 AD MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES ALTERNATING CURRENT NFPA D03 (CETOP 03) p max 5,000 psi Q max 18 GPM MOUNTING INTERFACE OPERATING PRINCIPLE NFPA D03 CETOP 4.2-4-03-350

More information

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND 48 900/103 ED LC* LP* LOGIC ELEMENTS CARTRIDGE VALVES ISO 7368 - DIN 24342 COVERS FOR CARTRIDGE VALVES ND 16-25-32-40-50 p max 420 bar Q max (see performance ratings table) OPERATING PRINCIPLE Logic elements

More information

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min 41 330/116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-05 p max 320 bar Q max 125 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-05-04-0-05 (CETOP 4.2-4-05-320)

More information

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 2/117 ED DSE3 DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 41-3 p max 3 bar Q max l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 41-3-2-- (CETOP 4.2-4-3-3). 33 3.2 21. 12.7.1.7

More information

I.T MDT * series 20 MODULAR DRIVEN TOOL DEVICE FOR AXIAL SYSTEM DIN 5480 / 5482 COUPLING TECHNICAL INFORMATION ISSUED

I.T MDT * series 20 MODULAR DRIVEN TOOL DEVICE FOR AXIAL SYSTEM DIN 5480 / 5482 COUPLING TECHNICAL INFORMATION ISSUED series 2 MODULAR DRIVEN TOOL DEVICE FOR AXIAL SYSTEM DIN 548 / 5482 COUPLING TECHNICAL INFORMATION I.T. 6486 GB The data given in the I.T. are subject to technical modifications without notice. ISSUED

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par 41 510/112 ED EXPLOSION-PROOF VERSION SOLENOID OPERATED DIRECTIONAL CONTROL VALVES in compliance with ATEX 94/9/EC MD1K ISO 4401-03 (CETOP 03) E4P4K CETOP P05 E07P4K ISO 4401-07 (CETOP 07) E5P4K ISO 4401-08

More information

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE 31 200/110 ED RS* DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30 THREADED PORTS CARTRIDGE TYPE p max (see table of performances) Q max (see table of performances) OPERATING PRINCIPLE The RS* and RS*-I

More information

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10 41 320/110 ED DS5JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVE ALTERNATING CURRENT NFPA D05 (ISO 4401-05 / CETOP 05) p max 4600 psi Q max 32 GPM MOUNTING INTERFACE NFPA D05 ISO 4401-05-0-04-05 (CETOP

More information

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE 14 100/117 ED PVD VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with mechanical pressure compensator. The pressure

More information

I.T ODT-N * series 50 MODULAR DRIVEN TOOL DEVICE FOR AXIAL SYSTEM DIN 1809 COUPLING TECHNICAL INFORMATION ISSUED

I.T ODT-N * series 50 MODULAR DRIVEN TOOL DEVICE FOR AXIAL SYSTEM DIN 1809 COUPLING TECHNICAL INFORMATION ISSUED series 50 MODULAR DRIVEN TOOL DEVICE FOR AXIAL SYSTEM DIN 1809 COUPLING TECHNICAL INFORMATION I.T. 6482 GB The data given in the I.T. are subject to technical modifications without notice. ISSUED 06-09

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP CMI Summary table Essential characteristic of the control unit compact CMI is the arrangement of the motor pump unit completely immersed in the oil inside

More information

Documentatie Stuurventielen DL3

Documentatie Stuurventielen DL3 Documentatie Stuurventielen DL3 De gegevens in deze documentatie zijn met de grootste zorg samengesteld, maar mogen geen reden zijn om ons aansprakelijk te stellen voor de gevolgen van fouten, die ondanks

More information

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL 16 100/110 ED VPPM VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE The VPPM pumps are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open

More information

The range of products is completed by a number of accessories, including:

The range of products is completed by a number of accessories, including: ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not

More information

Plug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30

Plug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30 CONTROL DEVICE REFERENCE STANDARDS UNSWITCH SOCKET OUTLETS EN 60669-1 Switches for household and similar fixed-electrical installation. Part 1: general requirements. Rated current: 10A-13A-15A-16A Rated

More information

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.7 Series PD directly operated solenoid valves New /-way Normally Closed (NC) Note: all Series PD /-way solenoid valves are basically in DC. To operate

More information

Solenoid System FLANGE MOUNTING VERSION

Solenoid System FLANGE MOUNTING VERSION EVI 9S Solenoid System COIL The EVI 9S system by AMISCO includes a wide range of solenoid operators designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter of 8

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Nominal operating pressure (continuous service) bar 160. Maximum operating pressure bar 210. Peak pressure bar 250. Maximum speed (standard) m/s 0,5

Nominal operating pressure (continuous service) bar 160. Maximum operating pressure bar 210. Peak pressure bar 250. Maximum speed (standard) m/s 0,5 71 /17 ED HC2 HYDRAULIC CYLINDERS SERIES 2 ISO 62/2 (1991 EDITION) DIN 24554 DESCRIPTION Double acting cylinders constructed in compliance with ISO 62/2 (1991 edition) and DIN 24554. The compact design

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current

More information

Flow Meter Terminal Boxes

Flow Meter Terminal Boxes Shutter Flow Meter Terminal Boxes Shutter Flow meter Terminal boxes 02 07 11 1 Shutter Valve DAROC Description and general specifications Production range and operating conditions Operation Installation,

More information

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO 41 600/117 ED DSH* LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO 4401-03 DSH5 ISO 4401-05 p max (see performances table) Q nom (see performances table) OPERATING PRINCIPLE The DSH

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 CONTENTS: RH06...1 - electrical control... RH06...2 - hydraulic control... Page 1/17...7/17 8/17...9/17 RH06...4 - mechanical control RH06...6 - pneumatic control......

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation

More information

Level Switches. Level Float Switch. Visual/Electrical Low Level. LEN Series RL Series. LV/E1 Series. S e c t i o n

Level Switches. Level Float Switch. Visual/Electrical Low Level. LEN Series RL Series. LV/E1 Series. S e c t i o n Level Switches Level Float Switch LEN Series RL Series Visual/Electrical Low Level LV/E1 Series S e c t i o n 5 Level Float Switch - LEN Series The electromagnetic level indicator activates an electric

More information

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS Electronic level and temperature control Gasket (NBR) Operating pressure: max. 1 bar Operating temperature: -20 C up to +80 C Ambient temperature: -20 C up to +70 C Weight: approx. 400g Sealing fl uid:

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces: Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating

More information

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER EVI 7 S8 Solenoid System COIL The EVI7 S8 system by AMISCO includes a wide range of solenoid operators designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter of

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...

More information

MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron

MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron Cast iron monobloc centrifugal electric pumps in compliance with EN 733. APPLICATIONS Moving clean water for civil, agricultural, industrial use, pressure boosting units, heating and air conditioning plants

More information

Series P directly operated solenoid valves

Series P directly operated solenoid valves > Series P solenoid valves CATALOGUE > Release 8.7 Series P directly operated solenoid valves 3/-way NC and NO. The solenoid valves can be mounted on a single base (with M5 ports) as well as on manifolds

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

Hydraulic Power Packs

Hydraulic Power Packs Hydraulic Power Packs Hydraulic Pump / Hydraulic Valve / Hydraulic Accessory ISO 9001:2008/ISO 14001:2004 283 Danforth Avenue, Suite 348, Toronto, ON Canada M4K 1N2 www.lprglobal.com / www.uskoreahotlink.com

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES S E R I E S P Directly operated mini-solenoid valves Series P 3/ way N.C. or N.O. Ports M5 (for single base) Cartridge ø 3 and 4 (for manifold) Note: All the serie P electrovalves are basic in DC. For

More information

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 14 110/117 ED PVE VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT OPERATING PRINCIPLE The PVE pumps are variable displacement vane pumps with direct pressure regulator. The pump group

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Hydraulic Components Oil tanks accessories Industrial controllers

Hydraulic Components Oil tanks accessories Industrial controllers Temperature control, indication and control of cooling and heating circles Excess temperature safety device of units Level control Used in hydraulic, lubrication and tempering units Up to 7 functions in

More information

REVERSIBLE HYDRAULIC POWER PACKS. 1 node/142/

REVERSIBLE HYDRAULIC POWER PACKS. 1 node/142/ REVERSIBLE HYDRAULIC POWER PACKS 1 node/142/ 2 Introduction Oil Sistem is a leader in power packs production and offers a wide range of solutions suitable for every type of application. Oil Sistem developed

More information

COILS, CONNECTORS, SOLENOID VALVES

COILS, CONNECTORS, SOLENOID VALVES COILS, CONNECTORS, SOLENOID VALVES 117 10 mm solenoids Solenoid valve 10 mm 00.441.0 Tension 24V DC ±10% Temperature range -5 C...+60 C (23 F... 140 F) Power 0.5... 1 W Operating pressure 0... 7 bar (0...

More information

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 40 202 PERFORMANCE CHART 80 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW 301 MECHANICAL SEAL 302 DIAGRAM

More information

5" SUBMERSIBLE PUMPS _ed.12/2014. Single member - Company subject to the control and coordination of Franklin Electric Co., Inc.

5 SUBMERSIBLE PUMPS _ed.12/2014. Single member - Company subject to the control and coordination of Franklin Electric Co., Inc. Vertical S.r.l. via Asolo, 7 36031 Dueville (Vicenza) - Italy Tel. +39 0444 361114 Fax +39 0444 365247 P.IVA e C.F. 00558130241 e-mail: sales@vertical.vi.it www.etechpumps.com Single member - Company subject

More information

Directional Control Valves Accessories

Directional Control Valves Accessories Plugs Description Plug EN 175301-803 *, style AF Protection class IP 65 for voltages up to 50V Plug with LED V DC Plug with lamp insert 10V AC Plug with lamp insert 30V AC Cable connection PG 9 PG 11 PG

More information

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

DIRECTIONAL CONTROL VALVES CETOP 3/NG6 CETOP 3/NG06 STANDARD SPOOLS CH. I PAGE 0 AD.3.E... CH. I PAGE AD.3.E...J* CH. I PAGE 2 AD3.XS... CH. I PAGE 3 AD3.XD... CH. I PAGE 4 AD.3.V... CH. I PAGE 5 AD.3.L... CH. I PAGE 6 OTHER OPERATOR CH. I

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

CLOGGING INDICATORS SUMMING-UP DESCRIPTION

CLOGGING INDICATORS SUMMING-UP DESCRIPTION SUMMINGUP CLOGGING PRESSURE FILTERS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential,

More information

Buchholz Relay MBP Gas and Oil Actuated Relay

Buchholz Relay MBP Gas and Oil Actuated Relay Buchholz Relay MBP Gas and Oil Actuated Relay Reed switches for detection of gas formation and dropping oil level Flap valve to protect in case of excessive high oil flow rate Separated oil and switching

More information

WP92. Ultimate press. Ultimate press. 0.4 kw Full load

WP92. Ultimate press. Ultimate press. 0.4 kw Full load WP92 Description Water pump Pump. Speed Ultimate press. Full load power Capacity Intake Exhaust Weight MVA 22.0071 MAD WP92 24 V DC 4500 rpm (without load) 1.3 bar 4 A 92 lt/min Ø38 mm Ø38 mm 1.7 kg Description

More information

Buchholz Relays Series RR - RRF - GQ

Buchholz Relays Series RR - RRF - GQ Buchholz Relays Series RR - RRF - GQ Catalogue N : 04RRCATR03-E Revision: 03 of 29.06.2004 04RRGENR05-E Buchholz Relays "Custos" Series RR, RRF, GQ 1 of 4 Function and construction, functional and operating

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048 COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications with both return

More information

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80 Electric pumps for professional applications to convey sewage water, entirely designed and manufactured in our Italian facility. APPLICATION PERFORMANCE RANGE To convey waste and sewage water from septic

More information

n 029/ June 2005 Page: 1

n 029/ June 2005 Page: 1 n 029/2005 - June 2005 Page: 1 TO ALL OUR CUSTOMERS 1. PRODUCT CHANGE: NEW ENCLOSURES AND DISCONNECTING SWITCHES FOR ISOLATORS 40A SERIES ISOLATORS 40A enclosures in thermoplastic and metal look new and

More information

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and

More information

Accessories Cable glands

Accessories Cable glands Accessories Cable glands 235 Technical data Cable glands Brass hexagon cable gland Brass sealing cable gland Material: Brass, nickel-plated Gasket: Soft rubber Protection type IP 54 Additional information:

More information

BZ40. Dal 1901 COD

BZ40. Dal 1901 COD COD. 9901.09 REV.00 POS CODE TABLE 1 Mod. PM DESCRIPTION 1 0709LW CUPS-HEATER GRID 7817801 SCREW TPS M X 1 18 WASHER FOR SPRING D H OT NICKEL-PLATED 01 ASSEMBLY CUPS-HEATER 91 ASSEMBLY BODY STAINLESS STEEL

More information

2011 AC & DC Hydraulic. Power Packs Compact. Rotation Ø 15 6,45 3,5 5,7

2011 AC & DC Hydraulic. Power Packs Compact. Rotation Ø 15 6,45 3,5 5,7 Ø 15 6,45 5,7 3,5 11 9 ±. C & DC Hydraulic Rotation ower acks Compact OWER CKS COMCT series ordering code C11/1-1 QUICK SELECTION GUIDE C & DC electric motors DC motors,15 1DC_T 1VDC motor - 15W - Ø 8

More information

MAGICA. Dal 1901 COD

MAGICA. Dal 1901 COD MAGICA Dal 90 COD. 9942049.02 REV.00 POS CODE TABLE DESCRIPTION 53205.0CM CUP-HEATER 2 5043LW CUPS-HEATER GRID STAINLESS STEEL POLISHED 3 03 TAPPING SCREW M4X3 4 4422 ADHESIVE FEET 5 50530LW CUPS-HEATER

More information

Product Catalog Evacuated tube collectors CPC OEM CPC w OEM

Product Catalog Evacuated tube collectors CPC OEM CPC w OEM Product Catalog 2004 Evacuated tube collectors CPC OEM CPC w OEM Table of Contents Development/design Production Outgoing goods warehouse Table of Contents Page Evacuated tube collectors CPC 6 OEM, CPC

More information

Liquid filled Thermometers

Liquid filled Thermometers Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus PNEUMATIC valves Series 77 & 78 Compact & Modular Valves Series 77 - Compact Valves Series 77 - LPP770 Series 77 - Sub-D Series 77 - Fieldbus Series 77 - LPP772 Series 77 - Coils & Plug-in sockets Series

More information

5" SUBMERSIBLE PUMPS. by Franklin Electric

5 SUBMERSIBLE PUMPS. by Franklin Electric 5" SUBMERSIBLE PUMPS INDEX NAUTI VN 5" Submersible Pumps... 2 General Product Curves... 3 Material Table... 3 Technical Data and Performance Curves VN 3..................................................................................................

More information

Temperature controls, Type RT

Temperature controls, Type RT MAKING MODERN LIVING POSSIBLE Technical brochure Temperature controls, Type RT RT temperature controls incorporate a temperature controlled, single-pole changeover switch where the contact position depends

More information

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING 4/3 and 4/2 Proportional directional valve elements L881 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING L881 (EDC-P1) RE 1831-1 Edition: 6.218 Replaces: 7.12.217 Size 6 Series Maximum

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 202 PERFORMANCE CHART VOX 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 DIAGRAM AND ELECTRIC CONNECTIONS 302 DIAGRAM

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

Mobile 2-Post Lift FHB 3000

Mobile 2-Post Lift FHB 3000 Mobile 2-Post Lift FHB 3000 + Mobile and versatile use, indoors and outdoors, without fixing to the floor. + Free access to any part of the vehicle, doors can be opened at any height. + Maximum safety

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally

More information

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries Contents Page D-Sub adapter... 40.02 Han Split Hood... 40.04 Cable entry protection with metric cable entries... 40.06 Cable entry protection with Pg cable entries... 40.08 Coding for Hoods/Housings and

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning In-Line centrifugal electric pumps with stainless steel hydraulic parts AISI 304. APPLICATIONS Civil/industrial heating plants Systems for moving domestic hot water Cooling and air conditioning plants

More information

Safety & Shut-off Blocks

Safety & Shut-off Blocks Safety & Shut-off Blocks Description HYDAC safety and shut-off blocks are designed to protect, shut-off, and discharge hydraulic accumulators or user units. The compact design simplifies the hydraulic

More information

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers

More information

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA OMAL S.p.a. Via Ponte Nuovo, 11-25050 Rodengo Saiano (BS) ITALY Phone +39 0308900145 - Fax +39 0308900423 Booked in the Enterprise Register of: Brescia number 1661640175 Share capital completely deposited:

More information

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32 Table C0701/E Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32 AGIRR20/***/V AGIU10/11...E Two stage pressure control valves with balanced poppet

More information

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL 14 201/118 ED RV1P VARIABLE DISPLACEMENT VANE PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS (measured with mineral oil with viscosity of 46 cst at 40 C) RV1P are variable displacement vane pumps with

More information

DM 06 MAGNETIC DRIVE CENTRIFUGAL PUMPS

DM 06 MAGNETIC DRIVE CENTRIFUGAL PUMPS DM 6 Product of Italian origin Available in PP-PVDF Below head use No welded seams Max. flow rate from 7 m 3 /h Max head 8, m Extremely easy maintenance Low cost of spare parts No fluid leaks Viscosity

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

LIG4 COD REV.00

LIG4 COD REV.00 P COD. 9942057 REV.00 TABLE 1 POS CODE DESCRIPTION 1 7816004 SCREW TCEI M4 X 16 2 5053027 COVER 3 5074478SG GROUP FRONTAL PM 4 5074635LW GRID 5 7474217 ADHESIVE FEET 6 5074621LW CUPS-HEATER GRID BZ07 BA

More information

Data Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve

Data Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve Data Pack G Issued March 1997 1502323412 Data Sheet RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve The RS electro-pneumatic interface is a modular solenoid valve, purpose made

More information

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw Condensers NEOSTAR 18 kw 12 kw Friga-Bohn reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual www NEW! The air cooled condenser units of the new NEOSTAR

More information

GP PUMP SIZE GP1 GP2 GP3 Displacement range cm 3 /rev clockwise, anticlockwise or reversible (seen from the shaft side)

GP PUMP SIZE GP1 GP2 GP3 Displacement range cm 3 /rev clockwise, anticlockwise or reversible (seen from the shaft side) 11 1/117 ED GP EXTERNA GEAR PUPS OPERATING PRINCIPE The GP pumps are fixed displacement external gear pumps with axial clearance compensation. They give high volumetric efficiency even with high operating

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute

More information

HYDRAULICS VINCKE INDUSTRIAL HYDRAULIC VALVES

HYDRAULICS VINCKE INDUSTRIAL HYDRAULIC VALVES VINCKE INDUSTRIAL HYDRAULIC VALVES TECH-VIHV-200.1 index 3 link to your page / link a su página 4VNKSV Directional on/off control 4 3 CETOP 3 3 CETOP 5 7 10 4VNKEH Electro-hydraulic directional control

More information

DATA REQUIRED Electric motor power/motor size Manufacturer and pump type

DATA REQUIRED Electric motor power/motor size Manufacturer and pump type A guide to select the correct bell-housing and drive coupling components DATA REQUIRED Electric motor power/motor size Manufacturer and pump type TO VERIFY: 1 - Pump and motor shaft dimensions (see page

More information

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB. Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium

More information