EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X USA NEC STANDARD

Size: px
Start display at page:

Download "EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X USA NEC STANDARD"

Transcription

1 EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X USA NEC STANDARD R NOT/E 10-0/05-08 CARACTERISTICS Hydraulic : Cetop. Maximum pressure in service : 15 Bar. Nominal flow. : 60 l/mn. 7 hydraulic symbols. Electric : Protection index : IP 66 / NEMAX. Standards : USANEC NFPA70, Class I, Div. 1-, Group B. Temperature range : T5. ED6 D5X/UL -DC-T5 05 PA DESCRIION OF FUNCTION Directional control valves type ED 6 are solenoid operated directional spool valves. They control start, stop and direction of an oil flow. These valves basically consist of the housing (1), one or two solenoids (), the control spool (), and return springs (). In unoperated condition the control spool () is held in the neutral or starting position by the return springs () (except for type O and OF). The operation of the control spool is by means of oil immersed solenoids (). The force of the solenoid () acts via the plunger (5) on the control spool () and pushes it from its rest position into the required end position. When the solenoid is de-energised (), the control spool () is returned to its original by the return springs (). An hand emergency button, allows movement of the control spool () without solenoid energisation. TYPE : ED6 C or D 5X/O these are directional valves with switching positions and solenoids without locking. When the solenoid is energised there is no median position (without return springs). TYPE : ED6 C or D 5X/OF these are directional valves with switching positions and solenoids with locking in position. CARDRIDGE THROTTLE Use of the cardridge throttle is necessary when, because of the given operating conditions, flow larger than that allowed by the valve operating limits arise during spool cross-over. 1 Throttle cartridge fited in "P "line of hydraulic valve. P the 5 A T (P) B.. ED6...5X...B0.. 1

2 SOLENOID GENERALITY Oil immersed direct curent solenoid (1) impervious to 100 bar maximum pressure, its mechanical impact strength is approved by the CENELEC for explosion proof equipment. Insulation to IP 66, it can work in tropical climates. The plunger operate in oil to reduce friction, dissipate head and cushions and drives control spool. Direct curent solenoid has the advantages of : - slow movement of the control spool. - energized maintenance of the control valve in intermediary position, is not detrimental to the solenoid. The solenoid housing can be oriented in steps of 90 on directional control valve. ELECTRIC CONNECTION An explosion proof connexion can be made on the solenoid housing by rigid conduit threaded 1/ N. 1 Seal integrated in the housing. The lead wire (1) length normally suplied is 1,5 meter. Active lead wire (1), Earth lead wire (). Threaded hole 1/ N ().

3 CARACTERISTICS HYDRAULIC Maximum operating pressure : Ports A, B, P. Bar Up to Maximum operating pressure : Port T. Bar Up to With spool type A and B, port T must be used as a drain port, if the operating pressure lies above 100 Bar. Maximum flow Hydraulic fluid Viscosity range Fluid temperature range L/Mn. mm²/s ( C) (see operating curves of pressure drop) Mineral oils, Weight : - valve with 1 solenoid (Kg) - valve with solenoids (Kg) 7 Mounting position : - Positions - Positions Optional. Optional - Horizontal prefered. Standard symbol : - positions D Y others symbols (see page 6) - positions E G J ELECTRICAL Continous voltages available. V/DC Temperature range with ambiente 0 C. T T5 Power requirement. Protection index. VA 16, IP 66 / Tropicalised - NEMA X Duty cycle. 100 % Maximum coil temperature. Outlet connection ( C). 10 C 1/"N STANDARD National electrical code Approval number Underwriters Laboratories File Number NEC NFPA 70 UL LISTED X6 E (N)

4 HYDRAULIC CODE REFERENCES ED X service ports service ports D Y OF O D D E J G Middle Position Normal position Hydraulic housing series number. 5X The above refer to symbols D, Y only. Without return spring, with locking control spool. Without return spring. With return springs No code OF O The above refer to E, J, G,... Ect. With one solenoid side A. With one solenoid side B. With one solenoid side A and side B.: No code A B For use when the flow is greater than the valve capacity, fitted in P line. Throttle Ø 0.8 MM : Throttle Ø 1,0 MM : Throttle Ø 1, MM : Without throttle : No code B08 B10 B1

5 ELECTRICAL CODE UL No code : Wires length 1.5 meter Wires length meters PB No code : Without control With control pushbutton side B PA No code : Without control With control pushbutton side A 05 Connection on body in 1/" N The lead wires length normally suplied is 1,5 Meter. T5 T... Temperature range. DC Direct curent (Only) Voltage. UL Solenoid conforme to the american standard for use in hazardous locations (UL100). 5

6 HYDRAULIC VARIATION SYMBOLS positions with one solenoid side A. = A With return spring. = C positions with one solenoid side B. = B positions with solenoid sideaand side B..../O Without return spring..../of With locking control spool. = A.../... = C.../... positions with one solenoid side A. a 0 a 0 =EA =E1A 0 positions with one solenoid side B. b 0 b =EB =E1B a positions with one solenoid side A & B. 0 b a 0 b =E =E1 =FA =FB =F =GA =GB =HA =HB =H =JA =JB =LA =LB =L =MA =MB =M =PA =PB =P =QA =QB =Q =RA =RB =R =TA =TB =T =UA =UB =U =VA =VB =V =WA =WB =W 6

7 DIMENSIONS (In mm) 1 : Side A solenoid housing. : Side B solenoid housing. : Hydraulic valve housing. : See for dimensions with manual control reset. 5 : x fixing screw M5 x : Lead wires ACE ED6 XXXXX UL DC- T Ref 8 Solenoid housing can be oriented all 90 on L = X For X dimension, see under With control pushbutton X = 180 maxi Ø 5 5 Without control pushbutton X = 10 Ø 5 7

8 OPERATING LIMITS CURVES OF PRESSURE DROP CURVE 7 : SYMBOL "R" IN SWITCHING POSITION : B - A CURVE 8 : SYMBOL "G" IN NEUTAL POSITION : P - T PRESSURE DROP P( bar) FLOW Q( L/mn) Mesured at V : 6 mm ² /S, t : 50 C HYDRAULIC VALVE CONNECTION CETOP T M5 x Ø 6 1 A P B

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE NOT/E 10-60/11-0 CARACTERISTICS Hydraulic : Cetop 3. Maximum pressure in service : 315 ar. Nominal flow. :

More information

EXPLOSION PROOF CHECK VALVE TYPE SEW6 SERIE 3X ATEX DIRECTIVE & CENELEC STANDARD

EXPLOSION PROOF CHECK VALVE TYPE SEW6 SERIE 3X ATEX DIRECTIVE & CENELEC STANDARD EXLOSION ROOF CHECK VALVE YE SEW SERIE X AEX DIRECIVE & CENELEC SANDARD NO/E 0-0/-0 CARACERISICS Hydraulic : Cetop. Maximum service pressure : 50 Bar. Nominal flow max. : l/mn. hydraulic symbols : / et

More information

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve 01/06 4/3, 4/2 and 3/2 explosion-proof solenoid directional valve Type G...WE10...L3X 2.22 Size (NG) 10 Up to 315 bar Up to 120 L/min Contents Function and configuration Specifications 03 Spool symbols

More information

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve. AP64E00DX00X Characteristics to VDI 90 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Spool valve Mounting screws M Tube connection Thread Port size ; 7.4 deep

More information

Q max (see specifications table)

Q max (see specifications table) 41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications

More information

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES 41 230/102 AD MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES ALTERNATING CURRENT NFPA D03 (CETOP 03) p max 5,000 psi Q max 18 GPM MOUNTING INTERFACE OPERATING PRINCIPLE NFPA D03 CETOP 4.2-4-03-350

More information

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60 41 300/198 ED D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 0 ALTERNATING CURRENT - SERIES 60 CETOP 0 p max 30 bar Q max 100 l/min MOUNTING INTERFACE DIRECT-ACTING SOLENOID OPERATED

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 01/08 /3, /2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 2.1 Type WE 10...L5X Size (NG) 10 Up to 350 bar Up to 150 L/min Contents Function and configurations -03 Specifications 0 Symbols 05

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X NEC STANDARD

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X NEC STANDARD EXLOSION ROOF DIRECIONL CONROL VLVE YE ED SERIE X NEC SNDRD CRCERISICS Hydrulic : Cetop. Mximum pressure in service : r. Nominl Flow mx. : 0 l/mn.(see tle) Directionl control vlves re solenoid operted

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par 41 510/112 ED EXPLOSION-PROOF VERSION SOLENOID OPERATED DIRECTIONAL CONTROL VALVES in compliance with ATEX 94/9/EC MD1K ISO 4401-03 (CETOP 03) E4P4K CETOP P05 E07P4K ISO 4401-07 (CETOP 07) E5P4K ISO 4401-08

More information

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25 41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

5/2 and 5/3 Way Valves

5/2 and 5/3 Way Valves Caracteristics to VDI 9 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Ceramic Spool Valve Mounting On base plate, Tube connection Base plate Port size G1/

More information

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Directional Control Valves, electrically operated Type WE 5 Huade América 1 Directional Control Valves, electrically operated Type WE 5 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Directional control valves, electrically operated Type WE 5 Size5 up to 25

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10 41 320/110 ED DS5JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVE ALTERNATING CURRENT NFPA D05 (ISO 4401-05 / CETOP 05) p max 4600 psi Q max 32 GPM MOUNTING INTERFACE NFPA D05 ISO 4401-05-0-04-05 (CETOP

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012 4/2 and 4/3 Way Directional Control Valves Pilot Operated RNEH4-25 HA 4024 7/2015 Size 25 (D 08) 320 bar (4600 PSI) 600 L/min (159 GPM) Replaces HA 4024 6/2012 Solenoid pilot operated directional valves

More information

General Specifications DRV DRV-Exm DRV-Exd

General Specifications DRV DRV-Exm DRV-Exd direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...

More information

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical feedback, Type 4WRA. Huade América 1

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical feedback, Type 4WRA. Huade América 1 4/2- and 4/3-way proportional directional valves, direct actuated, without electrical feedback, Type 4WRA Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. 4/2- and 4/3-way proportional

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 CONTENTS: RH06...1 - electrical control... RH06...2 - hydraulic control... Page 1/17...7/17 8/17...9/17 RH06...4 - mechanical control RH06...6 - pneumatic control......

More information

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002 4/2 and 4/3 Way Directional Control Valves Pilot Operated RPEH4-16 HA 4023 2/2003 Size 16 p max up to 320 bar Q max up to 300 L/min Replaces HA 4023 2/2002 Solenoid pilot operated directional valves (RPEH)

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external

More information

Series MGPS. Compact Guide Cylinder: ø50, ø80 MGP S Z73. How to Order. Applicable auto switches. Compact Guide Cylinder.

Series MGPS. Compact Guide Cylinder: ø50, ø80 MGP S Z73. How to Order. Applicable auto switches. Compact Guide Cylinder. Compact Guide Cylinder: Series S ø, Compact Guide Cylinder Compact guide cylinder Heavy duty guide rod type S Z73 mm mm How to Order Number of auto switches Nil S 2 pcs. 1 pc. Auto switch type Nil Without

More information

Solenoid valve VDHT standard BSP (British Standard Pipe)

Solenoid valve VDHT standard BSP (British Standard Pipe) Technical data sheet standard BSP (British Standard Pipe) danfoss.high-pressurepumps.com 521B1166 / DKCFN.PD.043.A1.02 Index 3. Picture Overview 4. Features 5. Technical data 6. Technical data 7. General

More information

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces: Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit. 1.1 PRODUCT APPLICATION INFORMATION WORKSEET The following information will aid you in selecting the correct magneto, upgrade kit, or ignition harness: 1. Engine Manufacturer 2. Engine Model Number 3.

More information

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41 83 250/198 ED D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP 05 p max 250 bar Q max (see performance ratings table) MOUNTING INTERFACE OPERATING

More information

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated Model 4 WRA(E)B Size 6 Series 1X

More information

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4 EV FT3 ES-FT5 ES/GB 4 15-07-2008 16:09 Pagina 4 5 1 HOW TO READ THE MODEL CODE FOR VALVES FT3 - ES - * FT3 - ES - (1) (C) - * - (024C) / 10 2 FUNCTIONAL SYMBOLS 1C 1N 1 2 3 4 5 6 7 1 FT3 4-way directional

More information

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching

More information

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback RA 29024/01.05

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W www.atos.com Table TE137obs/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification UL certified valves are obsolete

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

S.A. 193 Stefan Cel Mare str., 2400 Sibiu -Romania

S.A. 193 Stefan Cel Mare str., 2400 Sibiu -Romania S.A. H rd 193 Stefan Cel Mare str., 2400 Sibiu -Romania 1 240 l/min 315 bar Pressure control valves NG10,20,32 FC -9 GENERALITIES Pilot operated pressure control valves, available with/without by-pass

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10 27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING 4/3 and 4/2 Proportional directional valve elements L881 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING L881 (EDC-P1) RE 1831-1 Edition: 6.218 Replaces: 7.12.217 Size 6 Series Maximum

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING / and / Proportional directional valve elements L88 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING L88 (EDC-P) RE 181-9 Edition:.16 Replaces: 7.1 7.1 Size 6 Series Maximum operating pressure

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Solenoid valve VDHT standard BSP (British Standard Pipe)

Solenoid valve VDHT standard BSP (British Standard Pipe) Technical data sheet standard BSP (British Standard Pipe) danfoss.high-pressurepumps.com 521B1166 / DKCFN.PD.043.A1.02 Index 3. Picture Overview 4. Features 5. Technical data 6. Technical data 7. General

More information

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

S21 Series. - 1 NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight S21 Series - 1" NT - Brass Body - 2-Way iloted Diaphragm - s Seals: Nitrile, Viton, Ethylene ropylene Orifice: ilot Stainless Steel Main Brass Ø 1 Electrical Standard Housing: Encapsulated Waterproof Conduit

More information

2-way proportional throttle valve for block installation

2-way proportional throttle valve for block installation -way proportional throttle valve for block installation RE 90/07.05 Replaces: 03.00 / Types FE; FEE Size 6 Component series X Maximum operating pressure 35 bar Maximum flow 90 L/min bei p = 0 bar H4538

More information

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min 41 330/116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-05 p max 320 bar Q max 125 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-05-04-0-05 (CETOP 4.2-4-05-320)

More information

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES CONTINENTAL HYDRAULICS VSD*HL-*-KD2 HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES (IN COMPLIANCE WITH ATEX 94/9/EC) 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM

More information

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid valve VDHT Standard BSP (British Standard Pipe) MAKING MODERN LIVING POSSIBLE Data sheet Standard BSP (British Standard Pipe) high-pressurepumps.danfoss.com Contents 1. Picture overview...3 2. Introduction...4 3. VDHT valve selection overview...4 4.

More information

Shock/Vibration Control Switches

Shock/Vibration Control Switches Shock/Vibration Control Switches Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 ` Installation Instructions 00-02-0185 2013-02-01 Section 20 Please read the following information before installing.

More information

S21 Series. - 2" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

S21 Series. - 2 NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight S21 Series - 2" NT - Brass Body - 2-Way iloted Diaphragm - s Seals: Nitrile, Viton, Ethylene ropylene Orifice: ilot Stainless Steel Main Brass Ø 1 1/4 Electrical Standard Housing: Encapsulated Waterproof

More information

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev MODULAR UNIT 6MB GENERAL DESCRIPTION Figure 1 6MB-200-**-2C General Arrangement Rev. 5 5.1.1 Figure 2 General Arrangement 6MB-650-**-2C The Modular Units 6 MB is a complete unit for controlling of hydraulically

More information

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview R Safety Trapped Key Overview Key Coding Below is an example reference guide that is useful in selecting and tracking codes. Start down the Aa column as the lower codes (typically Aa to Za) are stocked.

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline inline hazardous location Manifold mounting 35 sub-base non plug-in sub-base with pressure regulators sub-base hazardous

More information

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK CONTINENTAL HYDRAULICS VED*MJ PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*MJ PILOTED

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND 48 900/103 ED LC* LP* LOGIC ELEMENTS CARTRIDGE VALVES ISO 7368 - DIN 24342 COVERS FOR CARTRIDGE VALVES ND 16-25-32-40-50 p max 420 bar Q max (see performance ratings table) OPERATING PRINCIPLE Logic elements

More information

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated Proportional cartridge throttle valve, with inductive position transducer, pilot operated RE 29215/09.05 1/18 Type FESX Nominal size 16, 25, 32, 40, 50 Unit series 1X Maximum working pressure A, B, X 315

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum

More information

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... 3 l/min, 420 bar Two pressure valve, ON / OFF or HI / LO With internal pilot drain to

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

Integrated Control modules

Integrated Control modules .604.0 - Rev: 6, Page of Integrated Control modules QC4, QC42 and QC43 Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in

More information

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison) Characteristics / Technical Data Series PE*W (Parker), RR (Denison) Subplate mounted proportional pressure reducing valves are available with both Parker (series PE*W) and Denison (series RR) model codes.

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information

S40 Series. - 1/4" NPT - Stainless Steel Body - 2-Way Piloted Piston - Normally Open. Dimensions/Weight

S40 Series. - 1/4 NPT - Stainless Steel Body - 2-Way Piloted Piston - Normally Open. Dimensions/Weight S40 Series - " NT - Stainless Steel Body - 2-Way iloted iston - Materials Seals: Nitrile, Viton, Teflon, Ethylene ropylene Orifice: ilot Stainless Steel Main Stainless Steel Ø 3/8 Electrical Standard Housing:

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves 60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design Directly Operated Pressure Relief Valves SRA-A2 HA 5063 7/202 3/4-6 UNF p max 350 bar (5080 PSI) Q max 30 L/min (7.9 GPM) Replaces HA 5063 8/200 Screw-in cartridge design 4 pressure ranges Pressure setting

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.

More information

ISO cartridge valves type LIM*, LIRA, LIC*

ISO cartridge valves type LIM*, LIRA, LIC* Table H000/E ISO cartridge valves type LIM, LIRA, LIC Pressure controls: relief, reducing, compensator, ISO 7368 size from 6 to 80 Pmax 40 bar Pressure control valves in ISO cartridge design specific for

More information

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves

More information

Proportional Directional Valves pilot operated type 4WRZ, external pilot operated type 4WRH

Proportional Directional Valves pilot operated type 4WRZ, external pilot operated type 4WRH Proportional Directional Valves pilot operated type 4WRZ, external pilot operated type 4WRH Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Proportional Directional Valves pilot operated

More information

Pilot control unit with end position lock for the remote control of directional valves

Pilot control unit with end position lock for the remote control of directional valves Pilot control unit with end position lock for the remote control of directional valves RE 64 553/02.07 1/12 Replaces : 05.05 Type 4THF6 or 5THF6 Series 2X Contents Functional description, section, symbol

More information