Lh=:3 connections (3/2 wv)

Size: px
Start display at page:

Download "Lh=:3 connections (3/2 wv)"

Transcription

1 ~~V::~~ "-"--~~~ 5pecification Refrigerant Valve KMV4 32 Lh=:3 connections (3/2 wv) Version 04 Refrigerant Valve Application The bi-stabie solenoid valve is used in combination ãåfrigerators, with freezing compartments in accordance with EN requirements. The valve has à selvice life of min switc'lcycles (equivalent to à span of approxirnately 10 years). The intemal construction ofthe valves is in compliance with DIN Valve Sealing Valve Sealing (internal) < 5 Vh in the new condition, DIN 8964 < 1 Î I/h at the end of the service life 2.2 Valve Sealing (external) < 0,5 g/a (Isobutane) oveã the entiãe service life, DIN 8964 Chemical Stability The materials which ñîòå in contact with the refrigerant àãå resistanto R 134à and R600a. À" intemal and extemal parts àãå suitaûe for the given application in compliance with DIN 8960 ànñ! regard to the refrigerants. Compressor oils present in the cooling circuits do not have àn adverse influence îï the function )f the valves îã the ageing resistance of the components. ò emperature Zones. storage temperature range Ñ. operating temperature range (ambient) Ñ. operating temperature range (refrigerant) Ñ 5. Electrical Requirements 5.1 Switching The bi-stabie solenoid valve is actuated via àn electronic impulse. Depending îï the position of the ãequired output, à minimum signal of 4 half-waves (positive îã negative) is ãequiãed. SYSTEMS APPLIANCE

2 ~ i I J ~ I I. oi! --,! _i î mains voltage 2ÇÎV/50Íz or 1 OQ-120V / 50-60Hz diode \ positiveimpulse pf\nl\- ~ switch /' valve negative 5.2 Operating Voltage The valve is suitaûe for use within à voltage range of 175 V V (2ÇQV version) 85 V -128 V ( V version). 5.3 Protection Class The valve is ÎÑ activated and meets class-11 protection requirements (reinforced insulation). The minimum thickness of the insulation solenoid to earth I air is 2 mò. The air-gap and earth creapage distances 018 mm àãå maintained Solenoid Coil Resistance Measuãed Üó ambient temp of Ñ R = 5110.î.æ 10 %(with 230V solenoid) R = 1328.î.æ 10 %(with 100V-120V solenoid) Voltage Strength The voltage is measuredüåòåån à pole of the direct line and àn aluminium foil tightly wrapped around the solenoid, îã yoke îã the valve tubes. À start of voitage of 1875 VAC is applied and the raised to 3750 VAC for 1 minute. APPLIANCE SYSTEMS

3 Q "~ ~~t~~j~. 5.6 Ålectrical Construction The valve is constructed so that the ñàûå cannot Üå pulled out of the casing if à force of 50 N is... - applied. The casing ñàï only üå removed with à tool. The electrical connections cannot üå touched. The casing is sealed so that water cannot penetrate into the valve when built-in during the wate. ã test of the ãefrigeratoã Functional Tests Flow Rate and Leakage The measurementakes place Üó means of rota.meter at à room temperature of Ñ with compressed air with à pressure ratio of 4/1 Üàã. The valve is operated in the mounting positlon and the media flow is measured. Rolomelet Flow Rate: Leakage: > 1000 I/h (compressedair ð=çüàr) < 5 Vh «0,13 Vh with compressed air ð=3üàã) 6.2 Switching-Function in the Refrigerant-cycle (ÊÌ) The valve is soldeãåd into the complete ãåfrigeãànt circuit. The valve is checked at àn ambientempeãatuãe of 500 Ñ. With à refrigerant-temperature of 600 Ñ, the valve must work in the voltage range of VAC (2ÇÎV version) îã from VAC (10Q-120V version). With à refrigerant-temperature of 800 Ñ, the valve must work in the voltage range of VAC (2ÇÎV version) îã VAC ( V version). APPLIANCE SYSTEMS

4 ., c~ ~ l í ~ ikr:::~ ~~ 6.3 Switching Function with Compressed Air As an altemative to point 6.2, it is possibie to conduct à functional test using compressed air. With à pressure ratio of 9/1 bar for coolant R600a and 16/1 bar for coolant R1 Ç4à the va/ve must çtill work perfectly with à minimum voltage of 175 VAC (2ÇÎV version) or 85 VAC ( V version) 6.4 Leakage Ò est The valve is connected to the leakage test device. The testing device geneãates à vacuum in the valve. À helium-atmosphere is generated around the valve. If leakage OCCUfs, helium is sucked irto the valve and measured Üó the testing device. The sensitivity of the measuring instrurnent must te set in such à way that approximately 0.5 g/a (Isobutane) ñàï üå measured. This value must not t å exceeded throughouthe duration of the test. 7. Heating of the Coil With the normal pulsed activation of the vatve, heating of the coil ñàï üå neglected. In the event t If àn electrical defect, the solenoid ñàï Üå exposed to the mains voltage îã rectified mains voltage. Th~ voltage is switched îï at the solenoid at àn ambient temperature of Ñ until the steady s~ate condition is achieved. The $otef'ioio has the insulation CIaSS F and consequently à limittemperature of Ò= 1900Ñ. \ I~re ~ LlI-II;Jr\J. Calculation of the temperature of the coil: ò coil = (Rw-Rc)/Rc. õ( 234,5 + Ò J + ÒÑ Rc = resistance of the solenoid in cold condition at Ò ê Rw = ãesistance of the solenoid in wa~ condition Mechanical Tests Firm Seating of the Terminal Tabs The te~inal tabs àãå tested with à force of 100 N in the push-on and pull-out diãåñtions. In à" otheã diãections the strength is 50 N. The terminal tabs àãå allowed to distort, but not to break off or ñîòå Ioose. The solenoid must ~ till Üå in opeãating condition. APPLIANCE SYSTEMS

5 8.2 Tab-Bending Test The termina\ tabs çãå bent upwards Üó 450 and then back into their original position (twice). The tabs must not break. The intemal wiring connection must remain intact (resistance test). 8.3 Test of the Copper Tubes The ñîððåã tubes àãå bent înñå Üó 450 then Üó 900 in the opposite direction and bent back agair into the initial position. The fixing point for bending is 50 mm from the soldered joint. The extemal seaing must still Üå guaranteed. 8.4 Securing the Ñàð The cables àãå correctly inserted and the ñàð is locked. Using à force of 50 N attempts àãå made to pull the ñàûå out of the casing. - parallel to the initial position of the ñàûå - perpendicular to the initial position of the ñàûå. Neither the ñàûå nîã the ñàð should ñîòå oft during the test. 8.5 Housing Hinge Test The hinge is bent 30 times Üó The hinge should not break oft. 9. Life Test 9.1 Air Test Room temperature: Voltage: ÐÅ ÐÀ Ñ 230 VAC V ÀÑ ( V version) = 4 Üàã compressed air = 1 Üàã The solenoid is electronically pulsed. Îï: Ç seconds Off: Ç seconds

6 ~ REFRIGERANT CONTROL V AL VE Measurement of flow rate and leak~e in accordance with point 6.1 at the beginning and after completing 100,000 operating cycles. Service life: min. 500,000 operating cycles. The flow rate is allowed to change Üó.t; 1 Î %. The leakage ñàï rise to à maximum of 1 Î I/h. The switch-function in point 6.Ç must üå ÎÊ. 9.2 Valve Test Install the valve into à complete R1 ç4à or R600a refrigerant circuit. Volt~e 230 VAC. R134a R600a Liquefaction-pressu ãå Vaporisation-pãessure 10:I: 1 bar 1,5 I 1 bar 5:t1bar 1,5:t 0,5 Üàã The solenoid is electrically switched. The test unit must üå built to detect refrigerant escape. The leakage must üå checked during every cycle. Ðåïîî 20 seconds, i.e. 10 seconds ðåã switch-position. Measurements and evaluation as in point Solenoid Service Life Ò est ò esto-date indicate à life expectancy of about 1 Î years. Furthåòþre, the tests àãå used to deterrnine possible weak points. The solenoid valve is subject to à heat exchange test. Storage 16 h in the oven at 1400 Ñ, subsequent storage 8 h at àn ambientemperature of :~50 Ñ. This process is repeated 80 times. The solenoid valve must still üå functional after this test. 10. Environment Tests The valve is subject to the following tests, after which, the valve should have ïî defects. The va!ues of fiow rate and leakage ñàï üå only recorded within the àññèãàñó of the measuring device. SYSTEMS APPLIAHCE

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive

More information

The galvanic separation of the primary or actuating circuit and the load circuits

The galvanic separation of the primary or actuating circuit and the load circuits RELAY BASICS Relays are electro magnetically operated switches. An actuating current on a coil operates one or more galvanically separated contacts or load circuits. The electro mechanical relay is a remote

More information

Module 4: Climate Control

Module 4: Climate Control ÂÂ ÂÂ Air-Conditioning Electronic Control Unit (ECU) Â Controlling Cabin Air Temperature Servo Motors Electric Servo Motors ÂÂ Air-Conditioning Electronic Control Unit (ECU) Automatic Climate Control Sensors

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

KE-M02 configuration Configuratie documentatie documentation KE-M02

KE-M02 configuration Configuratie documentatie documentation KE-M02 Configuratie documentatie KE-M02 1/32 2/32 3/32 4/32 5/32 General Technical Data for Compact Power Module KE series Through the years DCOC has developed a highly evolved modular system resulting in powerful,

More information

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil for control in potentially explosive areas Type BZ Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used

More information

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems Operating conditions of VRLA batteries in HVCBS and LVDBS Systems 1 GENERAL INFORMATION It is required to mandatorily adhere to these Conditions of Operation. This document should be filled in (the last

More information

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

SERIES TAP-CHANGER

SERIES TAP-CHANGER SERIES 090 - TAP-CHANGER Main characteristics This is an off-circuit tap changer. It means DO NOT OPERATE WHILE THE TRANSFORMER IS ENERGISED. Main characteristics of this tap-changer series are: dimensional

More information

Pressure operated water valve Type WVFX and WVS

Pressure operated water valve Type WVFX and WVS Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The

More information

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

VE Series. Class A Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various Class "A" Gas Valves Product handbook APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting furnaces,

More information

Operating Instructions for Elevator Buffers type LP

Operating Instructions for Elevator Buffers type LP Operating Instructions for Elevator Buffers type LP 1 Scope of application The Elevator Buffer type LP is an energy dissipation type buffer according to EN 81-1/2, EN 81-20, EN 81-50 5.5 and therefore

More information

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H LUV INVERTER SERIES Part 2 of 2 Self-diagnostics and Trouble-shooting 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H MAJOR COMPONENT CHECKING COMPRESSOR Use a multi-meter

More information

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base 3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base Sub-base Direct-acting, normally closed and normally open Brass and stainless steel body Electrical cable plug Form A With or without manual override

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

Problems with your 12/24V Booster?

Problems with your 12/24V Booster? Problems with your 12/24V Booster? Check this Trouble Shooting Manual for your answer 1. Tools Required 2. First Tests to conduct 2.1 Measure the Voltage at the Clamps 2.2 Testing the power (Amps) 3. Testing

More information

Electric Expansion Valve Type AKVO 10

Electric Expansion Valve Type AKVO 10 Data sheet Electric Expansion Valve Type AKVO 10 AKVO 10 is an electrically operated expansion valve designed for refrigeration plant. AKVO 10 has an internal filter. The AKVO 10 range covers a capacity

More information

Al-Saudia Virtual Academy Online Tuition Pakistan Pakistan Online Tutor Magnet and Electromagnetism

Al-Saudia Virtual Academy Online Tuition Pakistan Pakistan Online Tutor Magnet and Electromagnetism Al-Saudia Virtual Academy Online Tuition Pakistan Pakistan Online Tutor Magnet and Electromagnetism DEFINITION: A substance having ability to attract magnetic materials is called magnet. The properties

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82315 REL CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary ATASA 5 TH Study Guide Chapter 19 Pages 571 595 42 Points Please Read The Summary 1. The primary purpose of the charging system is to the battery with a constant and relatively low charge after it has

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm 2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm Lockable manual override as standard For liquid, gaseous and aggressive media Long service life, even in non-lube conditions

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc

More information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to

More information

Smart Battery Charger

Smart Battery Charger BATTERY CHARGER Smart Battery Charger Model No. WSC-1215 (SB) WSC-1230 (SB) WSC-2408 WSC-2415 Manual Please read this manual carefully before installing and starting up this device. Figure 1 WSC-1215SB

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1988 Toyota Celica 1988 Automatic A/C-Heater Systems Celica * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system, use only approved refrigerant recovery/recycling

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 1.0mm Pitch ZIF FPC Page 1 Top Entry Side Entry 1.0mm Pitch ZIF FPC Page 2 1.0 SCOPE. This specification covers performance, tests and quality requirements for 1.0mm Pitch ZIF FPC Connector 2.0 APPLICABLE

More information

PRODUCTS FOR ELECTRIC VEHICLE CHARGING STATIONS

PRODUCTS FOR ELECTRIC VEHICLE CHARGING STATIONS IN THE REGION. WE ALSO PROVE THIS WITH TOP COMPONENTS FOR THE ELECTRIC. MINIATURE CIRCUIT BREAKERS (M) IN THE REGION. WE ALSO PROVE THIS WITH TOP COMPONENTS FOR THE ELECTRIC. MINIATURE CIRCUIT BREAKERS

More information

Safety Guidelines. Handling instructions. the swiss power source

Safety Guidelines. Handling instructions. the swiss power source Handling instructions! Preventing Quality Problems To prevent the batteries of being discharged please observe the following rules. 1. Do not place batteries on a conductive surface (anti-static work mat,

More information

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20 MAKING MODERN LIVING POSSIBLE Data sheet Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV

More information

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

RoHS-Compliant Brushless Motor Systems FBL Series. Features

RoHS-Compliant Brushless Motor Systems FBL Series. Features Speed Control Systems RoHS-Compliant Brushless Motor Systems FB Series The FB Series consists of a high performance, compact, brushless motor and driver. This product is available with 75 W (1/1 HP) and

More information

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS 702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS > TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION... 4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION...

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

Autoranging Multimeter

Autoranging Multimeter Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil 2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal

More information

21.2 Electromagnetism

21.2 Electromagnetism In 1820 Hans Oersted discovered how magnetism and electricity are connected. A unit of measure of magnetic field strength, the oersted, is named after him. Electricity and Magnetism How can an electric

More information

MAGNETIC EFFECT OF ELECTRIC CURRENT

MAGNETIC EFFECT OF ELECTRIC CURRENT BAL BHARATI PUBLIC SCHOOL, PITAMPURA Class X MAGNETIC EFFECT OF ELECTRIC CURRENT 1. Magnetic Field due to a Current through a Straight Conductor (a) Nature of magnetic field: The magnetic field lines due

More information

VE4000 & VE5000 SERIES

VE4000 & VE5000 SERIES VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,

More information

Question 2: Around the bar magnet draw its magnetic fields. Answer:

Question 2: Around the bar magnet draw its magnetic fields. Answer: Chapter 13: Magnetic Effects of Electric Current Question 1: What is the reason behind the compass needle is deflected when it is brought close to the bar magnet? Compass needles work as a small bar magnet;

More information

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE SECTIONS: ENGLISH 2 NEDERLANDS 17 DEUTSCH 37 Victron Energy BV De Paal 35 1351 JG Almere-Haven The Netherlands Article number

More information

National 4 Physics - Electricity and Energy Summary Notes

National 4 Physics - Electricity and Energy Summary Notes Electromagnetism Magnetic fields Magnetic fields are found around any permanent or electromagnet. They are normally invisible but can be shown up by placing a sheet of paper over the magnet and sprinkling

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FO EFIGEATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC,

More information

DTC P0440 EVAPORATIVE EMISSION CONTROL SYSTEM MALFUNCTION DTC P0442 EVAPORATIVE EMISSION CONTROL SYSTEM MALFUNCTION

DTC P0440 EVAPORATIVE EMISSION CONTROL SYSTEM MALFUNCTION DTC P0442 EVAPORATIVE EMISSION CONTROL SYSTEM MALFUNCTION 0536 SFI SYSTEM (ZZGE) DTC P0440 EVAPORATIVE EMISSION CONTROL SYSTEM MALFUNCTION 057I003 DTC P044 EVAPORATIVE EMISSION CONTROL SYSTEM MALFUNCTION CIRCUIT DESCRIPTION The vapor pressure sensor, VSV for

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2 BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR 1.00.00 GENERAL 1.01.00 Make : Jinan Power Equipment Factory 1.02.00 Type : WX21Z-073LLT 1.03.00 Reference Standard : GB/T7064-2002

More information

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007 Instruction Sheet PA-00281 October 2007 PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls THE FLEXIBLE

More information

Page 1 of 29 Section 04-05: Suspension, Computer Controlled 1997 Town Car Workshop Manual DIAGNOSIS AND TESTING Procedure revision date: 05/16/2000 Suspension, Computer Controlled Inspection and Verification

More information

One-line distributor e.g. VEI-A. One-line aggregate GEI-A

One-line distributor e.g. VEI-A. One-line aggregate GEI-A Ungültig!!! Ersatz: P0768 GE71 One-line aggregate GEI-A Use: This aggregate is used as pump in central lubrication systems that are based on the one-line principle. General construction: Essentially, the

More information

MCF3 25CT Inrush-withstand

MCF3 25CT Inrush-withstand RoHS Pb Dimensions and construction: (mm) Case: End-cap substrate metal: End-cap primary plating: End-cap surface plating: Adhesive: Marking: Ceramic Copper t=0.25 mm Nickel plated, 0.5 μm or more Tin

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

Low backlash planetary gearheads

Low backlash planetary gearheads Power transmission technology Low backlash planetary gearheads Low backlash planetary gearheads DIMENSION SHEET» picture 1 B-B A-A C-C Centering DIN 332 (G) Optional with key as per DIN 6885 sheet 1 Planetary

More information

Pressure Control Equipment

Pressure Control Equipment Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

Direct-acting 2/2-way plunger valve

Direct-acting 2/2-way plunger valve Direct-acting 2/2-way plunger valve Type can be combined with Direct-acting and compact valve up to diameter of DN 6.0 Vibration-proof, bolted coil system Increased leak-tightness with welded plunger guiding

More information

Instruction General Vacuum Valve program

Instruction General Vacuum Valve program 032R9317 032R9317 Contents page 1.Introduction 2.Installation 2.1 Electromagnetically Operated Valve 2.2 Pneumatically Operated Valve 2.3 Manually Operated Valve 1-2 3-4 5-8 9-11 12 1 Introduction This

More information

DIY Bi-Metallic Strip

DIY Bi-Metallic Strip DIY Bi-Metallic Strip An introduction to the applications of thermal expansion and two-way switching. Written By: Mahaaveer BN 2018 Page 1 of 14 INTRODUCTION A bi-metallic strip is used to convert a temperature

More information

Pressure Sensor/PS-A (ADP5)

Pressure Sensor/PS-A (ADP5) Sensor PS-A sensor Built-in amplifi er and compensating circuit Features Built-in amplifier and temperature compensation circuit, no need for circuit design and characteristic adjustment High accuracy

More information

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

MAGNETIC EFFECTS OF ELECTRIC CURRENT

MAGNETIC EFFECTS OF ELECTRIC CURRENT MAGNETIC EFFECTS OF ELECTRIC CURRENT It is observed that when a compass is brought near a current carrying conductor the needle of compass gets deflected because of flow of electricity. This shows that

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

MIDDLE LOAD RELAY FOR SMART J/B

MIDDLE LOAD RELAY FOR SMART J/B MIDDLE LOAD RELAY FOR SMART J/B CN-M RELAYS (ACNM) New Compliance with RoHS Directive FEATURES. Best space savings in its class.. Compact and high-capacity A load switching.. Full line up (High heat-resistant

More information

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS MODEL: PST-15S-12A OWNER S MANUAL Please read this manual before operating your inverter. INDEX Contents General Safety & Installation... 3 Warning... 4 Description

More information

Drained coolant must be stored in a clean container for disposal or reuse.

Drained coolant must be stored in a clean container for disposal or reuse. Cooling System, Draining and Filling Special tools, testers and auxiliary items required Adapter (V.A.G 1274/8) Adapter V.A.G 1274 tester (V.A.G 1274/10) Hose clamp pliers (V.A.G 1921) Cooling system charge

More information

Electronically operated expansion valve for CO 2 Type AKVH

Electronically operated expansion valve for CO 2 Type AKVH MAKING MODERN LIVING POSSIBLE Technical brochure Electronically operated expansion valve for CO 2 Type AKVH AKVH are electrically operated expansion valves designed for refrigerating plants using R744

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

RESIDUAL CURRENT CIRCUIT BREAKER

RESIDUAL CURRENT CIRCUIT BREAKER Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces

More information

Cooling System Description and Operation

Cooling System Description and Operation Page 1 of 5 2008 Holden VE Sedan VE, WM, Caprice, Statesman, Lumina, Omega, VXR8 Service Manual Engine Engine Cooling Description and Operation Document ID: 1990377 Cooling System Description and Operation

More information

Diagnosis of fuel tank systems with fuel tank leak diagnosis module (DMTL)

Diagnosis of fuel tank systems with fuel tank leak diagnosis module (DMTL) Page 1 of 10 SIT-SIT-SI2002-160102890 Diagnosis of fuel tank systems with fuel tank leak diagnosis module (DMTL) All US models VIN: XXXXXXX Vehicle: 6'/E64/CONVERTIBLE/650i/N62/AUTO/USA/LL/2007/05 System

More information

CHAPTER 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT

CHAPTER 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT CHAPTER 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT Compass needle:- It is a small bar magnet, whose north end is pointing towards north pole and south end is pointing towards south pole of earth..hans Oersted

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Electric expansion valves Types AKVA 10, 15 & 20

Electric expansion valves Types AKVA 10, 15 & 20 Data sheet Electric expansion valves Types AKVA 10, 15 & 20 AKVA are electric expansion valves designed for ammonia refrigerating plant. The AKVA valves are normally controlled by a controller from Danfoss

More information

Evaporative Emission Control System Operation Description (Enhanced)

Evaporative Emission Control System Operation Description (Enhanced) Page 1 of 7 1999 Chevrolet Chevy Suburban - 2WD Escalade, Pickup (Classic), Suburban, Tahoe, Yukon (VIN C/K) Service Manual Document ID: 222842 Evaporative Emission Control System Operation Description

More information

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive MAKING MODERN LIVING POSSIBLE Design Guide VLT MCD 100 Soft Starter the single speed drive Contents Contents 1.1.1 Introduction 2 1.2 Technical Data 3 1.3.1 Functional Diagram 4 1.3.4 Wiring 5 1.3.5 Adjustments

More information

Pressure and temperature controls, Type CAS

Pressure and temperature controls, Type CAS MAKING MODERN LIVING POSSIBLE Pressure and temperature controls, Type CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special

More information

Page 1 of 50 Section 412-00: Climate Control System General Information DIAGSIS AND TESTING 1997 Mark VIII Workshop Manual Climate Control System Special Service Tool(s) 73 Digital Multimeter 105-R0051

More information

NFC. (Varistor Type NFC)

NFC. (Varistor Type NFC) NFC (Varistor Type NFC) Type NFC Varistors are made of semiconductor ceramic materials composed mainly of zinc oxide. They have nonlinear resistance that changes as a function of applied voltage. It has

More information

Electrical Control Valves

Electrical Control Valves 172 Electrical Control Valves Electrical Control Valves Electrical Control Valve Technology Thermostatic expansion valves and mechanical regulator valves have been used in the refrigeration and air conditioning

More information

TECHNICAL PRODUCT DOCUMENTATION

TECHNICAL PRODUCT DOCUMENTATION Page: 1 POSITIONER TYPE A703 Page: 2 CONTENTS 1. APPLICATION 3 2. TECHNICAL DESCRIPTION 3 2.1. Construction 3 2.2. Working rules 4 2.3. Dimensions of the positioner and types of performances 6 3. TECHNICAL

More information

M100F Incremental Motor Actuator R81F Interface Board

M100F Incremental Motor Actuator R81F Interface Board Installation Sheets Manual 121 Motor Actuators Section M Technical Bulletin M100F Issue Date 0493 M100F Incremental Motor Actuator R81F Interface Board Application Details Figure 1: M100 Motor Actuator

More information

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-8 RELAY CV RELAYS (ACV) Micro ISO Form C type Micro 8 plug-in type Micro ISO Form A type Micro 8 PC board type Compliance with RoHS Directive FEATURES Low profile:.

More information

4.1. Manufacturing field F2 Preformed and field coil windings

4.1. Manufacturing field F2 Preformed and field coil windings 4.1 Manufacturing field F2 Preformed and field coil windings 4.1.2.2 Manufacturing field F2 - Preformed and field coil windings 4.1.2.2.1 Range of services preformed coils One of the most important areas

More information

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES mm inch or more is assured as insulation distance between contacts (Snap-in mounting and 3 Form A type) Durability of 100,000

More information

Design Guide. VLT Soft Start Controller MCD 100

Design Guide. VLT Soft Start Controller MCD 100 Design Guide VLT Soft Start Controller MCD 100 Introduction The MCD 100 soft starters are designed for soft starting and stopping of 3 phase a.c. motors, thus reducing the inrush current and eliminating

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

RS Stock number

RS Stock number RS Stock number 617-0773 Description: For general purpose applications No memory effect Note: All batteries are supplied with only a residual charge and should be charged at the continuous charge rate

More information

COIL OPTIONS Besides coils ranging from volts AC & DC, the construction varieties are: non-molded, molded, high temperature, potted coil & ho

COIL OPTIONS Besides coils ranging from volts AC & DC, the construction varieties are: non-molded, molded, high temperature, potted coil & ho HOUSING OPTIONS Constructed of stainless steel, plated and painted steel. Styles include strain relief connector, single automotive,double automotive, AN connector, splice box, yoke, conduit, grommet,

More information

The Power of Reliability INSTRUCTION MANUAL

The Power of Reliability INSTRUCTION MANUAL The Power of Reliability INSTRUCTION MANUAL SAFETY & WARNINGS Read this manual carefully and understand all Warnings and Cautions before connections are made to the Inverter. If unsure about any aspects

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and servo operated versions, they can be applied in liquid, suction, and hot

More information

FEED WATER REGULATOR EVM-1F FOR CONTINUOS REGULATION

FEED WATER REGULATOR EVM-1F FOR CONTINUOS REGULATION 1. Feed water regulator type EVM 1 F 2. Electrode stand type C DN 50 100 / PN 16 100 with 2 electrodes type ENT 120. 3. Control range 15 mm. 4. HORA Feed water regulating valve with electric actuator.

More information

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information