Repair any problems or leaks before retrofitting. Affix labels to the vehicle showing conversion status. Observe all safety recommendations.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Repair any problems or leaks before retrofitting. Affix labels to the vehicle showing conversion status. Observe all safety recommendations."

Transcription

1

2 The use of R134a in mobile A/C systems designed for R-1 2 refrigerant causes higher discharge pressures (as much as 10-15%) and necessitates changing the compressor lubricant from mineral oil (5GS) to PAG oil (Sanden's SP-10 or SP-20) to ensure compatibility. These changes result in greater wear to the internal components of the compressor. Therefore, to ensure consistent and expected reliability, Sanden does not recommend using R134a in systems and compressors designed for R-1 2. However, Sanden understands the realities of the automotive service markets and consumer preferences. If a retrofit is required, please follow the vehicle manufacturer's published retrofit procedures. Ensure all work done complies with SAE recommended practices as described in J1660 & J1661: Repair any problems or leaks before retrofitting. Affix labels to the vehicle showing conversion status. Observe all safety recommendations. If an OEM retrofit procedure is not available, Sanden recommends the following procedure: Sanden Procedure for Conversion from R-12 to R134a 1. If the R-12 vehicle air conditioning system is operational, run it at idle with the A/C blower on high speed for five (5) minutes to optimize the amount of oil in the compressor. Recover all R-12 refrigerant from the vehicle's A/C system. Evacuate the A/C system for at least thirty (30) minutes to a vacuum of 29 in. Hg, using R-12 equipment, to remove as much R-12 as possible from the residue mineral oil. Remove all R-12 service equipment. 3. Remove the compressor from the vehicle. 4. Remove the compressor oil plug and then drain as much mineral oil as possible from the compressor body. 5. Drain mineral oil from the cylinder head suction and discharge ports while turning the shaft with a socket wrench on the clutch armature retaining nut. 6. Remove the existing R-12 receiver-drier or accumulator-drier from the vehicle and discard. Allow as much oil as possible to drain from the A/C hoses. 7. Change any 0-rings on the receiver-drier or accumulator-drier joints to approved HNBR 0-rings; check and replace other 0-rings that have been disturbed. 8. Replace the receiver-drier or accumulator-drier with a new R134a compatible one

3 which contains XH7 or XH9 desiccant. 9. If a CCOT system is being repaired due to compressor damage, or foreign matter is found in the oil drained from the system, this foreign matter must be removed from the system. At this time an in-line filter should be installed in the liquid line. Allow as much oil as possible to drain from the A/C lines when installing the filter. Change any 0-rings disturbed in the installation of the filter to approved HNBR 0-rings. 10. Perform any necessary repairs to the compressor or A/C system. 11. Using the original refrigerant oil quantity specification, add SP-20 or SP-1 0 oil to the compressor (SP-10 for TR, SDV-710, SDB-705, SDB-706 and SDB-709; SP-20 for all other SD compressors). 12. Replace the compressor oil plug 0-ring with an HNBR 0-ring. 13. Reinstall the compressor oil plug. The plug seat and 0-ring must be clean and free of damage. Torque the plug to ft lb (15-25 N m, kgf cm). 14. Change any seals at the compressor ports to approved HNBR seals. 15. Reinstall the compressor to the A/C system. 16. Disable the R-12 service fittings to prevent any refrigerant other than R134a from being used. Permanently install R134a quick connect service fittings to the A/C system. 17. Connect R134a service hoses and other equipment. Re-evacuate the system for thirty (30) minutes using the R134a equipment. 18. Charge the A/C system with RI 34a. Generally, about 5% (by weight) less than the R-12 charge amount is required. Leak check the system per SAE J1628 procedure. 19. If the A/C system is a CCOT type, which has been repaired due to damage or the discovery of foreign material in the oil drained from the system, run the system for sixty (60) minutes to capture this material in the filter installed in step 9. Recover the refrigerant, remove and dispose of the filter, reconnect the lines, evacuate for at least forty-five (45) minutes, and recharge the A/C system. This step should not be necessary for TXV systems, since the drier is fitted with an internal filter. 20. Check the A/C system operating parameters. The system should function correctly within acceptable limits of temperatures and pressures. This will ensure that the correct amount of R134a has been charged.

4 21. In extreme circumstances when expected cooling performance cannot be achieved and high discharge pressures are experienced, it may be necessary to add more condensing capacity to the A/C system. An electric fan(s) and/or a larger capacity condenser can be used. 22. Replace all R-12 compressor labels with retrofit labels per SAE J1660 in order to provide information on the R134a retrofit which has been performed. Basic Sanden R-12 Compressor Retrofit Specifications for Refrigerant Oil Retrofit PAG oil amount in fluid ounces (cc) Model Expansion valve systems Orifice tube systems SD ± 0.5 (100 ± 15) No standard SD ± 0.5 (165 ± 15) No standard SD ± 0.5 (210 ± 15) 9.5 ± 0.5 (280 ±15 ) SD-510 No standard 8.1 ± 0.5 (240 ± 15) SD ± 0.5 (135 ± 15) No standard SD ± 0.5 (135 ± 15) 8.1 ± 0.5 (240 ± 15) Note 1: For long hose, dual evaporator systems, etc. the procedure in the Service Manual should be used. Note 2: It is recommended that the oil quantity in all cases be reconfirmed after the compressor is installed.

5

SVE BULLETIN F-Series Super Duty with Aftermarket Auxiliary AC System Control

SVE BULLETIN F-Series Super Duty with Aftermarket Auxiliary AC System Control Q-255 2017 F-Series Super Duty with Aftermarket Auxiliary AC System Control Models Affected 2017 F-350, F-450, F-550 Chassis Cab applications with the addition of auxiliary air conditioning systems beginning

More information

1964 Chevrolet Impala Condenser Kit with Drier (021063)

1964 Chevrolet Impala Condenser Kit with Drier (021063) an ISO 900:2008 Registered Company 964 Chevrolet Impala Condenser Kit with Drier (02063) 8865 Goll St. San Antonio, TX 78266 Phone: 20-654-77 Fax: 20-654-33 www.vintageair.com 9036 REV B 03/0/6, PG OF

More information

Technical Service BULLETIN

Technical Service BULLETIN Technical Service BULLETIN Title: Models: 01 03 Sequoia TSB UPDATE NOTICE: The information contained in this TSB supercedes TSBs AC001 01 and AC001 02. The previous TSBs, AC001 01 and AC001 02, should

More information

WARNINGS. Maintenance must be properly done to avoid serious injury risks. Improper maintenance can result in injury or property damage.

WARNINGS. Maintenance must be properly done to avoid serious injury risks. Improper maintenance can result in injury or property damage. Foreword This service manual has been elaborated to help service personnel to provide efficient and correct service and maintenance on the TM31 (formerly called DKS 32) compressor (for HFC-134a) for automotive

More information

Compressor Installation Guide. Technical helpline :

Compressor Installation Guide. Technical helpline : Compressor Installation Guide Technical helpline : 0843 330 4097 Compressor Installation All air-conditioning repairs should only be undertaken by someone that has sufficient knowledge and training that

More information

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1955-56 FORD FAIRLANE & CROWN VICTORIA CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect Fit system, offer complete comfort capabilities in virtually

More information

Important information about your new a/c system. Please read the following directions prior to installing this a/c system.

Important information about your new a/c system. Please read the following directions prior to installing this a/c system. PAGE 1 Important information about your new a/c system. Please read the following directions prior to installing this a/c system. PN s: CK-7586258, CK-758642, CK-7586304, CK7586SBC, CK-7486NC Jeep CJ Series

More information

Small Block Ford Serpentine Drive System with & without Power Steering

Small Block Ford Serpentine Drive System with & without Power Steering an ISO 9001:2008 Registered Company Small Block Ford Serpentine Drive System with & without Power Steering 18865 Goll St. San Antonio, TX 78266 Phone: 210-654-7171 Fax: 210-654-3113 www.vintageair.com

More information

Installation Manual GM VIR Eliminator Kit

Installation Manual GM VIR Eliminator Kit Installation Manual GM 73-76 VIR Eliminator Kit Part # 15-211 *On some vehicles accumulator may interfere with engine compartment braces,. Braces will need to be either modified or removed in order to

More information

Refrigerant Changeover Guidelines. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines HCFC R-22 to HFC R-422A/D for Medium and Low Temperature Applications Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies,

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1994 Volvo 960 1994 Auto. A/C-Heater System Volvo 960 A/C SYSTEM SPECIFICATIONS AUTOMATIC A/C SYSTEM SPECIFICATIONS TABLE Application Specification Compressor Type... Sanden

More information

Tube Remover and Installer. and Installer Used for servicing Ford systems produced after Screen Extractor. Ford Aerostar Expansion

Tube Remover and Installer. and Installer Used for servicing Ford systems produced after Screen Extractor. Ford Aerostar Expansion gauges A/C FLUSH KIT Easy-to-use system removes refrigerant oil, moisture contaminants from system components lines during retrofitting compressor replacement. Kit includes rubber-tipped flush gun, canister

More information

Jeep Wrangler 4.0 Liter TJ Jeep Wrangler 2.5 Liter TJ Installation instructions

Jeep Wrangler 4.0 Liter TJ Jeep Wrangler 2.5 Liter TJ Installation instructions TM www.jeepair.com 1999 Jeep Wrangler 4.0 Liter TJ 1999-2001 Jeep Wrangler 2.5 Liter TJ Installation instructions Kit Information After 1994 every vehicle was designed for R134a refrigerant. The Jeep kit

More information

A/C LUBRICANT SPECIFICATION & REPLACEMENT GUIDELINES

A/C LUBRICANT SPECIFICATION & REPLACEMENT GUIDELINES A/C LUBRICANT SPECIFICATION & REPLACEMENT GUIDELINES When it comes to A/C compressors these days, you never know what to expect in terms of the type and amount of lubricant inside. Some A/C compressors

More information

Badger Truck Refrigeration, Inc. Warranty Policy

Badger Truck Refrigeration, Inc. Warranty Policy Badger Truck Refrigeration, Inc. Warranty Policy The manufacturer warrants each new heater, air conditioner or part to be free from defects in materials and workmanship under conditions of normal use and

More information

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

High Performance Vacuum Pump Model 15120A/15121A Operating Manual... High Performance Vacuum Pump Model 15120A/15121A Operating Manual... Operating Manual Table of Contents Warnings...1 CoolTech high performance vacuum pumps...1 Pump components...2 Before using your vacuum

More information

Comfort Pack Archived Part Lists PARTS LISTS

Comfort Pack Archived Part Lists PARTS LISTS Comfort Pack Archived Part Lists PARTS LISTS CPGXX38-X Description 14208336 Natural Gas Orifice - 38 14208343 LP Gas Conversion Kit - 38 14208329 Heat Exchanger Assembly - 38 14208332 Full Burner Body

More information

A Series UP90 UP120 UP150 UP170 Compressor Service Manual

A Series UP90 UP120 UP150 UP170 Compressor Service Manual TM A Series UP90 UP120 UP150 UP170 Compressor Service Manual A Group Compressor Service Manual Table of contents: 1. Specifications UP90/UP120/UP150/UP170. 1 Magnetic clutch 2 Rear cap.2 2. Component

More information

Air Conditioner for M915 A0/A1 Truck

Air Conditioner for M915 A0/A1 Truck RD-2-4530-0 Air Conditioner for M915 A0/A1 Truck INSTALLATION INSTRUCTIONS Install refrigerant compressor per instructions provided with compressor mount kit. CAUTION: Edges of sheet metal can be sharp!

More information

BEVERAGE-AIR DW94/79/64/49/SF34 PARTS MANUAL

BEVERAGE-AIR DW94/79/64/49/SF34 PARTS MANUAL BEVERAGE-AIR DW94/79/64/49/SF34 PARTS MANUAL 115V/60HZ & BEVERAGE-AIR PARTS MANUAL FOR DW94/79/64/49 SF34 DW94/64/49 (-29) (FROSTY BREW UNITS) ALL PURPOSE COLD R 2002 115V/60HZ DW94/79/64/49/SF34 CABINET

More information

84-86 Ford SVO Mustang AC Installation Guide

84-86 Ford SVO Mustang AC Installation Guide 84-86 Ford SVO Mustang AC Installation Guide This installation guide is for the AC installation kit from Late Model Restoration. The Vendor is Hose Wizards that manufactures this great kit that provides

More information

XV. Parts. Mobile Climate Control 303

XV. Parts. Mobile Climate Control 303 XV. Parts Mobile Climate Control 303 MCC Reference Manual 2014 XV.1. Valves and O-Rings Heater Solenoids Valve 26-0348 26-0330 26-0194 Heater solenoid valve 24V 3/4 3 way 26-0348 Heater solenoid valve

More information

TOOLS & SERVICE ITEMS

TOOLS & SERVICE ITEMS TOOLS SERVICE ITEMS Table of Contents TOOLS & SERVICE ITEMS ACCESSORIES... 463 MASTERCOOL HOSE CRIMPER... 368 CHARGING ADAPTERS... 473 OIL TYPES - CHART... 228 CHARGING HOSES... 472 OIL INJECTORS... 474

More information

High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2

High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2 High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15120A/15122A Manuel del Operador... 8 Pompe à Vide à Haut Rendement Modèle 15120A/15122A

More information

AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM AC-1 AIR CONDITIONING SYSTEM GENERAL INFORMATION DESCRIPTION TROUBLESHOOTING PREPARATION REFRIGERATION SYSTEM DRIVE BELT REFRIGERATION LINES COMPRESSOR RECEIVER CONDENSOR COOLING UNIT COOL/ICE BOX EVAPORATORS

More information

FLX. Compressor Series7. Delivering Excellence

FLX. Compressor Series7. Delivering Excellence FLX Compressor Series7 Delivering Excellence What is a FLX7? The FLX7 is Sanden s flexible compressor series. We started with the SD7H15 compressor known throughout the automotive and mobile HVAC industries

More information

Chevrolet Corvette with Factory Air Evaporator Kit (564174)

Chevrolet Corvette with Factory Air Evaporator Kit (564174) an ISO 9001:2015 Registered Company 1974-76 Chevrolet Corvette with Factory Air Evaporator Kit (564174) 18865 Goll St. San Antonio, TX 78266 Phone: 800-862-6658 Sales: sales@vintageair.com Tech Support:

More information

Mopar B-Body Evaporator Kit with Factory Air

Mopar B-Body Evaporator Kit with Factory Air an ISO 9001:2008 Registered Company 1969-70 Mopar B-Body Evaporator Kit with Factory Air 571065 Fits: Dodge: Coronet, Super Bee, Charger Plymouth: Satellite, Road Runner, GTX 18865 Goll St. San Antonio,

More information

FORD MUSTANG, MERCURY COUGAR WITH FACTORY AIR EVAPORATOR KIT

FORD MUSTANG, MERCURY COUGAR WITH FACTORY AIR EVAPORATOR KIT an ISO 9001: 2008 Registered Company 1967-68 FORD MUSTANG, MERCURY COUGAR WITH FACTORY AIR EVAPORATOR KIT 554168 F O R D 904178 REV E 4/8/16, 1967-68 MUSTANG/COUGAR w/ AC EVAP INSTR PG 1 OF 23 Table of

More information

INSTALLATION INSTRUCTIONS FOR AIRTECH II / TIE-IN. For Nissan NV

INSTALLATION INSTRUCTIONS FOR AIRTECH II / TIE-IN. For Nissan NV INSTALLATION INSTRUCTIONS FOR AIRTECH II / TIE-IN For Nissan NV Corporate Headquarters ProAir, LLC 28731 County Road 6; Elkhart, IN 46514 Phone: (574) 264-5494; Toll Free: 800-338-8544; Fax: (574) 264-2194

More information

an ISO 9001:2008 Registered Company CORVETTE

an ISO 9001:2008 Registered Company CORVETTE an ISO 9001:2008 Registered Company 1963-66 CORVETTE WITHOUT FACTORY A/C 561163 18865 Goll St. San Antonio, TX 78266 Phone: 800-862-6658 Sales: sales@vintageair.com Tech Support: tech@vintageair.com www.vintageair.com

More information

Understanding the Modern Automotive Air Conditioning System. Trainer: Grant Hand

Understanding the Modern Automotive Air Conditioning System. Trainer: Grant Hand Understanding the Modern Automotive Air Conditioning System Trainer: Grant Hand AUTOMOTIVE TRAINING SOLUTIONS PTY LTD Training for the future... Automotive Training Solutions IMPORTANT NOTE Copyright The

More information

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B)

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B) www.source1parts.com HVAC SERVICE PARTS NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B) Supersedes:Nothing 035-23123-001 Rev. A (1011) 1 of 8 CONDENSER ROOF (SEE FIGURE 2) EVAPORATOR

More information

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series General Information General Information P2 Series The newly developed variable displacement piston pumps from Parker Hannifin, designated P2, are intended for mobile applications, featuring a very compact

More information

WARNINGS. Maintenance must be properly done to avoid serious injury risks. Improper maintenance can result in injury or property damage.

WARNINGS. Maintenance must be properly done to avoid serious injury risks. Improper maintenance can result in injury or property damage. Foreword This service manual has been elaborated to help service personnel to provide efficient and correct service and maintenance on the TM21 model compressors (for HFC-134a) for automotive air conditioning.

More information

INSTALLATION INSTRUCTIONS FOR COZY CAB A-1 AIR CONDITIONING KIT

INSTALLATION INSTRUCTIONS FOR COZY CAB A-1 AIR CONDITIONING KIT INSTALLATION INSTRUCTIONS FOR COZY CAB A-1 AIR CONDITIONING KIT 05-11 INSTALLATION INSTRUCTIONS A-12235 Air Conditioner Kit Cab set up instructions; This air conditioning kit is designed to be used with

More information

Performance Prediction of Automotive Air Conditioning System for Different Driving Cycle Conditions

Performance Prediction of Automotive Air Conditioning System for Different Driving Cycle Conditions Performance Prediction of Automotive Air Conditioning System for Different Driving Cycle Conditions Rangarajan S a, Yamamuro Tsuyoshi b, SasiKumar M a, Kubo Masaaki b, Anand G a a Renault Nissan Technology

More information

SERVICE MANUAL. Valeo TM08, TM13, TM15 & TM16 Compressors. Copyright 2013 Valeo Japan CO., LTD. All rights reserved.

SERVICE MANUAL. Valeo TM08, TM13, TM15 & TM16 Compressors. Copyright 2013 Valeo Japan CO., LTD. All rights reserved. SERVICE MANUAL Valeo TM08, TM13, TM15 & TM16 Compressors Copyright 2013 Valeo Japan CO., LTD. All rights reserved. Foreword This service manual has been elaborated to help service personnel to provide

More information

Ford Falcon, Ranchero Evaporator Kit (554150)

Ford Falcon, Ranchero Evaporator Kit (554150) an ISO 9001:2008 Registered Company 1964-65 Ford Falcon, Ranchero Evaporator Kit (554150) 18865 Goll St. San Antonio, TX 78266 Phone: 210-654-7171 Fax: 210-654-3113 www.vintageair.com 905140 REV A 06/23/15,

More information

Volkswagen > Golf, Jetta, GTI, Cabrio > Heating Air Conditioning 87 - A/C controls and mechanical components, servicing

Volkswagen > Golf, Jetta, GTI, Cabrio > Heating Air Conditioning 87 - A/C controls and mechanical components, servicing x-ebahn:///c:/program%20files/ebahn/data/vw-a-a3-h28ebn/vw/a/a3/repair%20ma Page 1 of 13 Volkswagen > Golf, Jetta, GTI, Cabrio > 1993-2002 Heating Air Conditioning 87 - A/C controls and mechanical components,

More information

High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2

High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2 High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15401/15601 Manuel del Operador... 8 Pompe à Vide à Haut Rendement Modèle 15401/15601

More information

t EVAPORATOR PRESSURE REGULATING VALVES

t EVAPORATOR PRESSURE REGULATING VALVES CATALOG 201 Page 63 t EVAPORATOR PRESSURE REGULATING VALVES (S)ORIT-12, -15 and -20 Features n High side pilot for improved temperature control and low P operation n Adjustable n Optional solenoid stop

More information

CORVETTE WITH FACTORY AIR EVAPORATOR KIT an ISO 9001:2008 Registered Company

CORVETTE WITH FACTORY AIR EVAPORATOR KIT an ISO 9001:2008 Registered Company an ISO 9001:2008 Registered Company 1963-66 CORVETTE WITH FACTORY AIR EVAPORATOR KIT 564163 904149 REV C 10/31/16, INST 63-66 CORVETTE EVAP w/ AC PG 1 OF 26 Table of Contents PAGES 1. COVER 2. TABLE OF

More information

YEAR MODEL APPLICATION O.E.M. # PART NO. 38,48,49,58,59,69

YEAR MODEL APPLICATION O.E.M. # PART NO. 38,48,49,58,59,69 Section I: Trucks Western Star BLOWER MOTORS YEAR 2011 2005 All... Main Unit (cw) w/oe#... RD58663-0... 01-1610 2004 1996 All... Main and Aux w/red Dot A/C (cw) w/oe#... RD38657-0... 01-1401 2003 1993

More information

a/c clutch and coil kits

a/c clutch and coil kits The Mopar advantage a/c compressor 100% New Gaskets and O-rings Axial Plate Piston Rear Cover 100% New Shaft Seal Valve Plate & Suction Reed 100% New Piston Rings 100% New Ball Shoes Front & Rear Cylinder

More information

SPARE PARTS CATALOG OFFICE PRO 18. DocID: 00G00077EB

SPARE PARTS CATALOG OFFICE PRO 18. DocID: 00G00077EB SPARE PARTS CATALOG DocID: 00G00077EB Table of Contents No. UNIT PART NUMBER SERIAL NUMBER RANGE REFRIGERANT SECTION 1 GX8000-711 GX8000-710 007XXXX180 to Present (From April 2007 to Present) R10A Page

More information

Temperature Control. New. Sa l e s Gu i d e. Tools Equipment Service Items. & much more

Temperature Control. New. Sa l e s Gu i d e. Tools Equipment Service Items. & much more Temperature Control Tools Equipment Service Items & much more New Sa l e s Gu i d e Recover / Recycle / Recharge - Equipment 3 Recover / Recycle / Recharge - Accessories 10 Refrigerant Identification 11

More information

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) MAKING MODERN LIVING POSSIBLE Data sheet Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) A CPCE hot gas bypass regulator is used to adapt compressor capacity to actual evaporator

More information

Classic Auto Air INSTALLATION INSTRUCTIONS CHRYSLER SANDEN COMPRESSOR CONVERSION KIT

Classic Auto Air INSTALLATION INSTRUCTIONS CHRYSLER SANDEN COMPRESSOR CONVERSION KIT Classic Auto Air INSTALLATION INSTRUCTIONS CHRYSLER SANDEN COMPRESSOR CONVERSION KIT Congratulations! You have just purchased the highest quality, best performing factory air conversion kit ever designed

More information

Eclipse 2000 Service Parts

Eclipse 2000 Service Parts This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior

More information

SEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT

SEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT SEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT PRODUCTS SPECIFICATIONS In a world where energy efficiency and sustainability

More information

CHAPTER 4 PARTS PARTS BY PICTORIAL. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation.

CHAPTER 4 PARTS PARTS BY PICTORIAL. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. CHAPTER 4 PARTS PARTS BY PICTORIAL This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description for Serial

More information

Technical Information

Technical Information Date of last update: Sep 12 Ref: Application Engineering Europe COPELAND SCROLL COMPRESSORS USING VAPOUR INJECTION FOR REFRIGERATION CONTENTS 1 Introduction... 2 2 Principle of operation... 2 3 Capacity

More information

CHAPTER 4 PARTS. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation.

CHAPTER 4 PARTS. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. CHAPTER 4 PARTS PARTS BY PICTORIAL This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description for Serial

More information

Volkswagen Golf > VW Rabbit GTI 2006-> (A5)

Volkswagen Golf > VW Rabbit GTI 2006-> (A5) Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> (A5) A/C Refrigerant System General information Note: General A/C refrigerant system servicing procedures (e.g., component/system descriptions, extracting

More information

Application Bulletin 141. H82J Series OVAL HOUSING ROUND HOUSING. BENCHMARK Compressor with Refrigerant R410A. (33,000 50,000 BTU/Hr.

Application Bulletin 141. H82J Series OVAL HOUSING ROUND HOUSING. BENCHMARK Compressor with Refrigerant R410A. (33,000 50,000 BTU/Hr. H82J Series OVAL HOUSING (13,000 36,000 BTU/Hr.) ROUND HOUSING (33,000 50,000 BTU/Hr.) Application Bulletin 141 BENCHMARK Compressor with Refrigerant R410A Page Application Bulletin Number: 141 Release

More information

HC-IL.ESA.W l April Extended Service Agreement Program. For Heatcraft Refrigeration Products. Wholesaler/Contractor.

HC-IL.ESA.W l April Extended Service Agreement Program. For Heatcraft Refrigeration Products. Wholesaler/Contractor. HC-IL.ESA.W l April 2018 Extended Service Agreement Program For Heatcraft Refrigeration Products Wholesaler/Contractor Protection WELCOME Welcome to the Heatcraft Refrigeration Products Extended Service

More information

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011) Air Handlers ACBX32CM 3 Phase Multi-Position ACBX32CM-100 (07/2011) FEATURES AND BENEFITS Application Environmentally friendly R410A refrigerant 3, 4, and 5 ton nominal capacities Multi-position applications

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50Hz. Units Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Date 6/13 Table Of Contents

More information

REMOVAL AND INSTALLATION

REMOVAL AND INSTALLATION 303-03-1 Engine Cooling 303-03-1 REMOVAL AND INSTALLATION Radiator, Cooling Fan and Shroud Special Tool(s) Wrench, Fan Clutch Nut 303-240 (T84T-6312-D) Holding Wrench, Fan Pulley 303-239 (T84T-6312-C)

More information

34.0 EMF SERIES FLAKERS EMF 450, EMF800, EMF1106 AIR, WATER AND REMOTE

34.0 EMF SERIES FLAKERS EMF 450, EMF800, EMF1106 AIR, WATER AND REMOTE Shaded Code indicates updated information AIR COOLED 5 Air Condenser 9141002-01 X 5 Air Condenser 9141017-01 X 5 Air Condenser 9141046-01 X 10 Fan Blade 9131133-02 10 Fan Blade 9131133-01 X 10 Fan Blade

More information

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 ) Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 ) Bulletin No. 82-00A Suitable For: Ammonia, Fluorocarbons, Nitrogen and Carbon Dioxide Features ASTM 352 LCB Cast Steel

More information

Accumulators -See Filter Driers BLOWER MOTORS

Accumulators -See Filter Driers BLOWER MOTORS Chevrolet/GMC Section I: Trucks Accumulators -See Filter Driers BLOWER MOTORS 2005 1999 All w/ A/C (Front auxmtr) (w/wheel) 5246608601-0212 2001 1996 All w&w/o AC (Front A/C) (w/wheel) 5246608001-0212

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

18SP712 EPA07 DD15/16 Three-Filter Fuel System to Two-Filter KM59 GEN1 Fuel System Conversion Service Kit (P/N: A )

18SP712 EPA07 DD15/16 Three-Filter Fuel System to Two-Filter KM59 GEN1 Fuel System Conversion Service Kit (P/N: A ) 18SP712 EPA07 DD15/16 Three-Filter Fuel System to Two-Filter KM59 GEN1 Fuel System Conversion Service Kit (P/N: A4710901055) KIT DESCRIPTION This service kit includes all necessary parts to convert the

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

COMMISSIONING Tick the tests carried out by attendee.

COMMISSIONING Tick the tests carried out by attendee. COMMISSIONING Model SN= Software version= Registration of A/C service station calculation on www.brainbee.com/ (reserved area) Registration code= Software available by Clima Solution Software version =

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

1999 E-Series Workshop Manual

1999 E-Series Workshop Manual http://www.fordservicecontent.com/pubs/content/~wsxm/~mus~len/21/sxm31c16.h... Page 1 of 3 SECTION 303-01C: Engine 6.8L 1999 E-Series Workshop Manual IN-VEHICLE REPAIR Procedure revision date: 06/30/1998

More information

A. VEHICLE INSPECTION PROCEDURE

A. VEHICLE INSPECTION PROCEDURE MAZDA3 AND MAZDA5 POWER STEERING VOLUNTARY SAFETY RECALL ATTACHMENT IV MAZDA3 AND MAZDA5 POWER STEERING VOLUNTARY SAFETY RECALL A. VEHICLE INSPECTION PROCEDURE 1. Verify that the vehicle is within the

More information

Idle Free Systems, Inc. Reference Guide System Component Information

Idle Free Systems, Inc. Reference Guide System Component Information Idle Free Systems, Inc. Reference Guide System Component Information #68004 REV 3 #68004 REV 3 Idle Free Reference Sheets System Components & Trouble shooting Table of Contents RF # 101.0 102.0 103.0 104.0

More information

MODEL : 55A240IUBEM ROTARY COMPRESSOR SPECIFICATION SHEET 1. APPLICATION 2. COMPRESSOR DATA 3. MOTOR DATA 4. ELECTRICAL COMPONENTS

MODEL : 55A240IUBEM ROTARY COMPRESSOR SPECIFICATION SHEET 1. APPLICATION 2. COMPRESSOR DATA 3. MOTOR DATA 4. ELECTRICAL COMPONENTS SPECIFICATION SHEET 1. APPLICATION H/P & Cooling Type Air conditioner Rated & Frequency... 208~230V 1Φ 60Hz Refrigerant.. R-22 2. COMPRESSOR DATA Pump Type Rolling Piston Type Displacement. 33.43cc/rev

More information

COMMERCIAL WALK-IN COOLERS AND FREEZERS

COMMERCIAL WALK-IN COOLERS AND FREEZERS COMMERCIAL WALK-IN COOLERS AND FREEZERS LSA Models Ideal for coolers above +34 F Low Silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 Btu/hr./10 F TD LSE, LSR and LST Models

More information

CELEBRATING 26 YEARS OF SERVICE SOLUTIONS 2016 CATALOG 2014 CATALOG OE-APPROVED, TECHNICIAN-FRIENDLY OE-APPROVED, TECHNICIAN-FRIENDLY

CELEBRATING 26 YEARS OF SERVICE SOLUTIONS 2016 CATALOG 2014 CATALOG OE-APPROVED, TECHNICIAN-FRIENDLY OE-APPROVED, TECHNICIAN-FRIENDLY 2016 CATALOG 2014 CATALOG OE-APPROVED, TECHNICIAN-FRIENDLY PROTECT TRANSMISSIONS FROM DEBRIS page 4 STOP COMPRESSOR DEBRIS page 23 BEFORE AFTER RESTORE HEADLIGHT LENS CLARITY page 42 QUICKLY CONNECT METAL

More information

GENERAL INSTRUCTIONS. PERFORMER-PLUS CAMSHAFT / LIFTERS / LUBE KIT MODEL: c.i.d. Chevrolet V8 Engines CATALOG #2117

GENERAL INSTRUCTIONS. PERFORMER-PLUS CAMSHAFT / LIFTERS / LUBE KIT MODEL: c.i.d. Chevrolet V8 Engines CATALOG #2117 Page 1 PERFORMER-PLUS CAMSHAFT / LIFTERS / LUBE KIT MODEL: 283-400 c.i.d. Chevrolet V8 Engines GENERAL INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. Most installations

More information

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KEP-PDI-2 Part # 1104191 PRODUCT SUPPORT web: k-rp.com/kep email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KEP Extended Profile Evaporator Air, Electric,

More information

PERFORMER RPM Camshaft/Lifters/Lube Kit CATALOG #7122 MODEL: c.i.d. Ford V8 (not for Boss 302 or 1985 & later roller lifter engines)

PERFORMER RPM Camshaft/Lifters/Lube Kit CATALOG #7122 MODEL: c.i.d. Ford V8 (not for Boss 302 or 1985 & later roller lifter engines) PERFORMER RPM Camshaft/Lifters/Lube Kit MODEL: 289-302 c.i.d. Ford V8 (not for Boss 302 or 1985 & later roller lifter engines) PLEASE study these instructions carefully before installing your new camshaft.

More information

Inverter scroll compressors VZH single and manifold

Inverter scroll compressors VZH single and manifold Application guidelines Inverter scroll compressors VZH088-117-170 single and manifold R410A http://cc.danfoss.com Content VZH088-117-170 - single compressors... 4 VZH088-117-170 - hybrid manifolding...

More information

This information covers the proper procedure for replacing the Volvo D16F engine in a VT or VNL chassis.

This information covers the proper procedure for replacing the Volvo D16F engine in a VT or VNL chassis. Volvo Trucks North America Greensboro, NC USA Engine, Replacement DService Bulletin Trucks Date Group No. Page 10.2007 210 139 1(47) Engine, Replacement Volvo D16F VNL, VT W2005773 This information covers

More information

High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2

High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2 High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15401/15601/15603 Manuel del Operador... 8 Pompe à Vide à Haut Rendement

More information

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized

More information

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/ TYPE TUA(E), TUB(E), TUC(E), T(E)2, TDE, TDEB, TE, TXI 2, AKV Thermostatic Expansion Valves Valve Applications Features Models Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A

More information

NCT-1000 Users Manual

NCT-1000 Users Manual NCT-000 Users Manual NCT 000 KIT 3 6 5 9 0 7 8 0 5 6 7 8 9 3 NCT-000 KIT. TOOL CASE. RAIL PLUG (mm) 5ea ( for spare) 3. RAIL PLUG (mm) 5ea ( for spare). FLASK & HOLDER ea 5. VISIBLE TUBE ea 6. INJECTOR

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

Curved Glass Bakery Cases Installation and Operation Manual

Curved Glass Bakery Cases Installation and Operation Manual Turbo Air Speeds up the Pace of Innovation Curved Glass Bakery Cases Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment. TCGB-36-2

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Warranty Field Campaign. ISV5.0 Fan Support Safety Campaign for Tiffin

Warranty Field Campaign. ISV5.0 Fan Support Safety Campaign for Tiffin ISV50 Fan Support Safety Campaign for Tiffin Breeze RV https://quickservecumminscom/qs3/pubsys2/xml/en/campaign/2018/c1885html Page 1 of 4 4/23/2017 Campaign Number Revision Level Date Group Number C1885

More information

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: START-UP INSTRUCTION OPTIMUM 36000 To 72000 BTU S PACKAGE UNITS 3 To 6 Ton START-UP CHECKLIST Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

More information

Brake Bleeding: Service and Repair

Brake Bleeding: Service and Repair 2008 Lexus GS 460 V8-4.6L (1UR-FSE) Copyright 2013, ALLDATA 10.52SS Page 1 Brake Bleeding: Service and Repair BRAKE: BRAKE FLUID (for 1UR-FSE): BLEEDING BRAKE: BRAKE FLUID CAUTION: Bleeding without the

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011 Scotsman Repair Kit - Water Reg. 3/8" Only PN: 11-0559-01 V46, V47, and V246 Valves (3/8 in. to 1-1/2 in. Sizes) and V48, V49, and V248 Valves (1/2 in. to 1-1/4 in. Sizes) Repair Kits Installation Instructions

More information

Condensed Catalog 410A January 2008

Condensed Catalog 410A January 2008 CATALOG Page 1 Condensed Catalog January 2008 This condensed catalog contains product specifically for R- applications. By including a minimum of engineering information we are able to provide a concise

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

SERVICE BULLETIN EXAMINING COMPRESSOR FAILURES IN THE FIELD

SERVICE BULLETIN EXAMINING COMPRESSOR FAILURES IN THE FIELD Form #COM-304AS SERVICE BULLETIN EXAMINING COMPRESSOR FAILURES IN THE FIELD This guide can be used as a reference to diagnose compressor failures, and is specifically designed to help you differentiate

More information

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: START-UP INSTRUCTION START-UP CHECKLIST SERIES 5 36000 To 72000 BTU S PACKAGE UNITS 3 To 6 Ton Date: _ Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up

More information

LUI / LUO. Condensing Units

LUI / LUO. Condensing Units UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST.. 585457 1 TABLE OF CONTENTS SECTION PAGE INTRODUCTION.. 3 INSTALLATION PROCEDURES Air Conditioner Location...4 Air Conditioner Mounting 4 A/C Ducting Installation...5 Power Kit Installation (Batteries)...5

More information

18SP680Rev3 EPA04 MBE 4000 Car Hauler Low Pressure Fuel Lines

18SP680Rev3 EPA04 MBE 4000 Car Hauler Low Pressure Fuel Lines 8SP680Rev3 EPA04 MBE 4000 Car Hauler Low Pressure Fuel Lines KIT DESCRIPTION These service kits include all necessary parts to replace the low pressure fuel lines between the fuel filter housing and fuel

More information

HEATER & AIR CONDITIONER SECTIONHA CONTENTS IDX

HEATER & AIR CONDITIONER SECTIONHA CONTENTS IDX HEATER & AIR CONDITIONER SECTIONHA GI MA EM LC EC CONTENTS FE PRECAUTIONS...2 Supplemental Restraint System (SRS) AIR BAG and SEAT BELT PRE-TENSIONER...2 Precautions for Working with HFC-134a (R-134a)...3

More information