1 HUDSON TECHNOLOGIES S Chiller dehydration & decontamination (online & offline) Refrigerant moisture reduction (online & offline) Rust and particulate reduction Hermetic burnout decontamination Residue and particulate removal & decontamination Oil logged chiller decontamination Chiller decontamination including elimination of mineral oil OTHER SERVICES Refrigerant recovery Refrigerant/oil sampling & analysis Refrigerant reclamation Cylinder maintenance Lithium Bromide recovery, disposal & analysis Glycol recovery, disposal & analysis SF6 recovery PRODUCTS Refrigerant sales Refrigerant buyback

2 HERMETIC BURNOUT CLEANUP Hermetic motor burnout is one of the most time consuming and expensive repairs chiller owners ever face. If the contaminants are not thoroughly removed, a costly secondary burnout becomes more likely. Recovers and reclaims your refrigerant at benchmark speeds up to 6,000 lb/hr using our unique and proprietary ZugiBeast at your job site Decontaminates centrifugal screw or reciprocating chillers in hours not days Removes contaminants as the refrigerant circulates throughout the system using the ZugiBeast s unique on site reclamation capabilities Decreases the need for cleanup kits, extra filter cores and suction dryers Minimizes the chance of a second premature burnout

3 CHILLERS DAMAGED BY RUPTURED TUBES Water can get into refrigerant from ruptured evaporator/condenser tubes, leaking tube sheets, tube leaks or ice trapped in refrigeration circuits. The smallest amount can lead to expensive repairs. Even more costly is when moisture ingresses into compressors and motors. Recovers and reclaims your refrigerant at benchmark speeds up to 6,000 lb/hr using our unique and proprietary ZugiBeast at your job site Minimizes expensive water damage to compressors and motors Removes all water and other contaminants from the refrigerant using the ZugiBeast s unique on site reclamation capabilities Minimizes down time with fast response and rapid evacuation of the system Salvages the maximum amount of refrigerant, saving on the cost of replacement refrigerant

4 HIGH PRESSURE CHILLER CONVERSIONS When chillers are being converted to operate with HFC refrigerants, building managers and service contractors are looking for ways to reduce the cost of this expensive and time consuming procedure. Technicians at Hudson developed an innovative method to speed up the process and save money at the same time. Speeds conversion of centrifugal, screw or reciprocating chillers to R-134a Recovers and reclaims your CFC or HCFC refrigerants at benchmark speeds up to 6,000 lb/hr using our unique and proprietary ZugiBeast at your job site Removes all traces of mineral oil using the ZugiBeast s unique on site capabilities Saves money by eliminating the need for costly POE oil change outs

5 LARGE SYSTEM RECOVERY When looking to convert existing equipment to alternate refrigerants, plant managers are confronted with the issue of time. Downtime can be extremely costly and every minute equipment is down results in a loss of production. Hudson s unique and proprietary ZugiBeast ensures that even the largest conversions can be completed in the minimum possible time. Rapid response puts liquid overfeed system repair ahead of schedule High speed on-site recovery speeds conversion to R-134a Removes all traces of mineral oil using the ZugiBeast s unique on site capabilities Online dehydration/moisture reduction removes moisture with no downtime

6 CROSS CONTAMINATED REFRIGERANTS Refrigerant that has become cross contaminated with chemicals or other refrigerants is very expensive to dispose of. Hudson s unique and proprietary ZugiBeast equipment recovers refrigerant on site. The recovered refrigerant is then removed from your job site by Hudson and subsequent full separation of contaminated refrigerant occurs in our processing facilities. Removes all traces of mineral oil using the ZugiBeast s unique on site capabilities Separates cross contaminated refrigerant saving you the cost of disposal fees for mixed refrigerants Online dehydration and moisture reduction of your system removes moisture with no operating downtime

7 CHILLER MOISTURE REDUCTION & DEHYDRATION Moisture reductions can be performed on wet systems that are not completely saturated with water. This service will prevent the need for costly, full-blown dehydrations. In the event that a full blown dehydration is required, Hudson s service can cut the time required by weeks with the help of our unique and proprietary ZugiBeast. The single most significant result is the removal of residual contaminants, which would be left in the system when using traditional methods such as vacuum pumps and air-drying. Removes residual contaminants using the ZugiBeast s unique on site capabilities Cuts weeks off the dehydration process Reduces chiller downtime Rapidly dehydrates air-cooled units Minimizes the chance of rust or corrosion Frees your technicians for other profitable work, thereby increasing your service revenues

8 RUST & PARTICLE DECONTAMINATION With so many ways for moisture to enter a system, rust and related particulate contamination has always been a problem for chiller and refrigeration systems. Tubing with rust buildup can degrade a chillers performance so much that it must be shut down. Will dissolve rust and other particulates from all tube surfaces, even in newly enhanced system designs In many cases eliminates the time and expense of re-tubing Regains lost system capacity Restores heat transfer efficiency

9 SF6 (SULFUR HEXAFLUORIDE) RECOVERY SF6 is widely used as an insulating and arc quenching gas in medium and high voltage transformers. As equipment ages, it is being repaired or replaced with more efficient equipment which typically uses 1/3 the quantity of SF6. T`his creates a need to recover the SF6 for recycling or disposal. Ambient temperature and equipment construction both have effects on the difficulty of SF6 recovery. FOR SF6 SERVICE Recovers and reclaims your SF6 at your job site Minimizes down time with fast response and rapid evacuation of SF6 systems Recovers the maximum amount of SF6 gas possible Provides complete handling, recycling and disposal documentation for use in your EPA reporting

10 Vapor Pressure in psig In Vacuum inches in Hg VAPOR TEMPERATURE R409A Temp Temp R422D R404A R507 R502 R402AR402BR408A LIQUID VAPOR F C F C LIQUID VAPOR

11 Vapor Pressure in psig In Vacuum inches in Hg PRESSURE TEMPERATURE Temp R11 R113 R114 R123 R124 R500 F C Temp R13 R23 R503 R508B F C

12 Vapor Pressure in psig In Vacuum inches in Hg PRESSURE TEMPERATURE Temp R22 R407C R410A R12 R134a R401A R401B F C LIQUID VAPOR LIQUID VAPOR LIQUID VAPOR

HCFCs Refrigeration Retrofit Guidelines

HCFCs Refrigeration Retrofit Guidelines Honeywell Genetron Refrigerants HCFCs Refrigeration Retrofit Guidelines R-12 to: MP39/R-401A MP66/R-401B R-409A R-502 to: HP80/R-402A R-408A Table of Contents HCFC Retrofit Guidelines........................1

More information

RELIABLE AND EFFICIENT SYSTEMS

RELIABLE AND EFFICIENT SYSTEMS RELIABLE AND EFFICIENT SYSTEMS Systems must be leak-free as possible All systems leak Piping materials are slightly porous Very small leaks are not detectable and do not affect system efficiency Some systems

More information

Refrigerating Engineers & Technicians Association. Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package

Refrigerating Engineers & Technicians Association. Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package Refrigerating Engineers & Technicians Association Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package - June 1, 2007-1 Commonly Used Refrigerants Refrigerant Number

More information

Refrigerant Recovery Programs

Refrigerant Recovery Programs Recovery Programs RSD can provide a full complement of refrigerant recovery, reclaim and reprocessing services. Our programs are flexible and can be tailored to meet the specific needs of each customer

More information

US PETROLON LUBRICATION & FILTRATION CATALOG.

US PETROLON LUBRICATION & FILTRATION CATALOG. US PETROLON LUBRICATION & FILTRATION CATALOG wwwuspetroloncom 2 US PETROLON INDUSTRIAL about us IMPROVING MACHINERY LIFE WITH SPECIALTY LUBRICANTS AND FILTRATION 447 n 66th unit 3 lincoln, ne 68505 phone

More information

6. Document tasks performed during visit and report any observations to the appropriate

6. Document tasks performed during visit and report any observations to the appropriate Chiller Annual Maintenance RFP Attachment B Services Required Tasking: Vibration Analysis 1. All work shall be performed in accordance with safety policies 2. Check with appropriate customer representative

More information

R-22 R-404A/R-502/R-507A R-12/

R-22 R-404A/R-502/R-507A R-12/ EMERSON CLIMATE TECHNOLOGIES-System Protectors Recommended System Tonnage Take-Apart Liquid Line Filter Driers in Tons* Description, Low Temp. & Commercial Installations Air Conditioning Field Replacement

More information

SF 6 Gas Reclaimers Zero Emissions. No Substitutes.

SF 6 Gas Reclaimers Zero Emissions. No Substitutes. SF 6 Gas Reclaimers The DILO L-Series gas reclaimers are the culmination of decades of SF6 specific R&D and provide the most cutting-edge technology on the market today in safety and performance. Using

More information

REFRIGERANT RECOVERY PRODUCTS

REFRIGERANT RECOVERY PRODUCTS REFRIGERANT RECOVERY PRODUCTS PARKER REFRIGERANT RECOVERY PRODUCT Parker provides a large selection of components for recovery, recycle and reclaim machines, protecting them from the many types of contaminants

More information

Models

Models Models 15300 15301 15500 15501 SAFETY PRECAUTIONS WARNING! To prevent personal injury, Wear goggles when working with refrigerants. Contact with refrigerants may cause injury. Incorrect use or connections

More information

Eliminator Liquid line filter driers, type DCL and DML

Eliminator Liquid line filter driers, type DCL and DML Eliminator Liquid line filter driers, type DCL and DML Flare connection Solder connection (copper) REFRIGERATION AND AIR CONDITIONING Technical leaflet Eliminator Liquid line filter driers, type DCL and

More information

Operating Manual. High Performance Vacuum Pump Models and 15600

Operating Manual. High Performance Vacuum Pump Models and 15600 Operating Manual High Performance Vacuum Pump Models 15400 and 15600 CoolTech High Performance Vacuum Pumps Congratulations on purchasing one of Robinair s top quality CoolTech vacuum pumps. Your pump

More information

Repair any problems or leaks before retrofitting. Affix labels to the vehicle showing conversion status. Observe all safety recommendations.

Repair any problems or leaks before retrofitting. Affix labels to the vehicle showing conversion status. Observe all safety recommendations. The use of R134a in mobile A/C systems designed for R-1 2 refrigerant causes higher discharge pressures (as much as 10-15%) and necessitates changing the compressor lubricant from mineral oil (5GS) to

More information

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS INSTALLATION, START-UP AND SERVICE INSTRUCTIONS P705 Refrigeration Condensing Units CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INTRODUCTION.................................. 1 HANDLING.......................................

More information

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING Selection & Application guidelines Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING www.danfoss.com 50 HZ BLUESTAR PRODUCT PROGRAMME....... p 3 Product

More information

FDB Filter Drier. FDB Filter Drier. Technical Data

FDB Filter Drier. FDB Filter Drier. Technical Data Technical Data ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Cushioned flow for non-turbulent

More information

REFRIGERATION LUBRICANTS

REFRIGERATION LUBRICANTS REFRIGERATION LUBRICANTS 1 Matrix Specialty Lubricants Matrix Specialty Lubricants is a company based in The Netherlands, producing and marketing specialty lubricants and greases. Matrix Specialty Lubricants

More information

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

High Performance Vacuum Pump Model 15120A/15121A Operating Manual... High Performance Vacuum Pump Model 15120A/15121A Operating Manual... Operating Manual Table of Contents Warnings...1 CoolTech high performance vacuum pumps...1 Pump components...2 Before using your vacuum

More information

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls SPRING CHECK LIST ABSORPTION CHILLERS Check starter and control panel. Leak test. Check hand valve diaphragms and replace as required. Check operation of purge unit. Change oil in the purge pump. Lubricate

More information

DCY. Anti-acid filter driers Refrigeration & Climate Components Solutions. n Applications

DCY. Anti-acid filter driers Refrigeration & Climate Components Solutions. n Applications 1.12 n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations. n Functional features Products are compatible with

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction

More information

HC-IL.ESA.W l April Extended Service Agreement Program. For Heatcraft Refrigeration Products. Wholesaler/Contractor.

HC-IL.ESA.W l April Extended Service Agreement Program. For Heatcraft Refrigeration Products. Wholesaler/Contractor. HC-IL.ESA.W l April 2018 Extended Service Agreement Program For Heatcraft Refrigeration Products Wholesaler/Contractor Protection WELCOME Welcome to the Heatcraft Refrigeration Products Extended Service

More information

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, DCL and DML Flare connection Solder connection (copper) Technical brochure Contents Page Introduction........................................................................................

More information

Air Conditioning Service Tools & Equipment

Air Conditioning Service Tools & Equipment 01/04/16 G2 R-410A Service Manifold & Gauges (BlackMax ) MBHP5E MV4H4P5EZ Exclusive TripleSeal valve system Valve stems retract fully for maximum flow Back seating o-ring seals valve nut when fully open

More information

Revolution in Revolutions

Revolution in Revolutions Revolution in Revolutions DESIGNED TO MEET CHALLENGES Industry needs reliable and affordable power The power industry is changing, driven by the need for technical Changes in reservoir design innovation

More information

Refrigerant Changeover Guidelines. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines HCFC R-22 to HFC R-422A/D for Medium and Low Temperature Applications Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies,

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction

More information

AEON. Compressor Lubricants

AEON. Compressor Lubricants Compressor Lubricants 2 Protect Your Investment Lubricants simply the best protection of your investment. Gardner Denver Compressor Lubricants It is a known fact that a compressor s is its life-blood,

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

ADK Filter Drier. Alco Controls. Filter Drier. Features

ADK Filter Drier. Alco Controls. Filter Drier. Features ADK is a hermetic filter-drier with internal solid block for use on liquid line. Features Solid block Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder connection made from copper

More information

FILTER DRIERS - SPORLAN

FILTER DRIERS - SPORLAN FILTER DRIERS - SPORLAN The universal acceptance of the Catch-All Filter-Drier is due to its unique moulded porous core, consisting of a blend of highly effective desiccants. The quality features built

More information

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder

More information

REFRIGERANTS AND LUBRICANTS

REFRIGERANTS AND LUBRICANTS Service Engineers Section Bulletin No 10 REFRIGERANTS AND 1.0 INTRODUCTION - THE NEED FOR IN REFRIGERATION SYSTEMS Lubricants (oils) are required in refrigeration systems to: Reduce friction by interposing

More information

Forane 427A Refrigerant

Forane 427A Refrigerant Forane 427A Refrigerant A NEW - % HFC - EASIER RETROFIT FOR EXISTING HCFC-22 INSTALLATIONS www.forane 427A.com Forane 427A Refrigerant A New Retrofit for HCFC-22 no equipment change necessary similar performance

More information

ISEL Refrigeration Fluids

ISEL Refrigeration Fluids ISEL Refrigeration Fluids Revenue by Product Line Revenue by Refrigeration Product Lubricants associated with the ammonia refrigeration industry make up >63% of the company s refrigeration lubricant sales

More information

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS TOTALINE LIQUID LINE FILTER DRIERS P502-8 SERIES P PART NUMBER SIGNIFICANCE P353 FEATURES Compacted bead filter drier Universal Replacement CFC, HCFC, HFC refrigerants Filtration first for more effective

More information

Semi-hermetic GEA Compressors. Single- and two-stage reciprocating compressors (HG/HA)

Semi-hermetic GEA Compressors. Single- and two-stage reciprocating compressors (HG/HA) Semi-hermetic GEA Compressors Single- and two-stage reciprocating compressors (HG/HA) 2 Introduction Advanced competence, in touch with you In this brochure we present our current program of single-stage

More information

LISTEN TO THE LIFEBLOOD OF YOUR MACHINE

LISTEN TO THE LIFEBLOOD OF YOUR MACHINE CAT SOS SERVICES SM LISTEN TO THE LIFEBLOOD OF YOUR MACHINE WARNING: YOUR FUEL TRANSFER PUMP IS LEAKING REPAIR BEFORE FAILURE SAVINGS: $32,000 FULL MENU OF FLUID ANALYSIS CAPABILITIES CAT SOS SERVICES

More information

Series PCS Portable Coalescence Separation Oil Purifier

Series PCS Portable Coalescence Separation Oil Purifier Series PCS Portable Coalescence Separation Oil Purifier ATTN: Mr. Kevin Dube Tel/Fax: 0086 23 8823 9845 Mob/WhatsApp: 0086 135 2739 0908 Email: sales@fuootech.com, kevinnchiang@gmail.com Add: No.5 Hongshi

More information

The Importance of Air Quality

The Importance of Air Quality Air Quality Guide The Importance of Air Quality Particulate Filter Dryer Air Compressor Drain Traps Atmospheric Compressed to 125 psig The act of compressing atmospheric air to 125 psig creates an 800%

More information

High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2

High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2 High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15401/15601 Manuel del Operador... 8 Pompe à Vide à Haut Rendement Modèle 15401/15601

More information

FACT SHEET 12 Mobile air-conditioning

FACT SHEET 12 Mobile air-conditioning FACT SHEET 2 Mobile air-conditioning UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April 205. Description

More information

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T Central chillers and pump tanks for processors in the plastics, food, chemical, pharmaceutical, printing, and machine tool industries

More information

Pressure Control Type KPU

Pressure Control Type KPU MAKING MODERN LIVING POSSIBLE Data sheet Pressure Control Type KPU KPU controls are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or

More information

HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22

HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22 HCFC-22 Retrofits A c l o s e l o o k a t t h e r e f r i g e r a n t / l u b r i c a n t i n t e r a c t i o n s. B y S a m u e l F. Y a n a M o t t a, E l i z a b e t D. V e r a B e c e r r a, R o n

More information

Parker TEV Model Visual

Parker TEV Model Visual PARKER - THERMOSTATIC EXPANSION VALVES TXV MODEL NUMBER SELECTION Parker TEV Model Visual N Series TEV C(E) Series TEV SC(E) Series TEV Applications: Applications: Applications: Low Profile Coolers, Rail

More information

US PETROLON. LUBRICATION & FILTRATION CATALOG

US PETROLON. LUBRICATION & FILTRATION CATALOG US PETROLON LUBRICATION & FILTRATION CATALOG wwwuspetroloncom 2 US PETROLON INDUSTRIAL about us IMPROVING MACHINERY LIFE WITH SPECIALTY LUBRICANTS AND FILTRATION 447 n 66th unit 3 lincoln, ne 68505 phone

More information

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING. MAKING MODERN LIVING POSSIBLE Solenoid valves EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical

More information

USPI Oil Defender System COLOR-CODED START/STOP DESICCANT BREATHERS OIL LEVEL SIGHT GLASSES STAINLESS STEEL TOTES

USPI Oil Defender System COLOR-CODED START/STOP DESICCANT BREATHERS OIL LEVEL SIGHT GLASSES STAINLESS STEEL TOTES US Petrolon Industrial Oil Defender Lube Room Solution Combined storage and filtration systems provide the best solution for an efficient lube room to dispense fluids that are clean and dry from the start

More information

High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2

High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2 High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15401/15601/15603 Manuel del Operador... 8 Pompe à Vide à Haut Rendement

More information

AMERILUBE ADVANCED TECHNOLOGY LUBRICANTS COMPRESSOR LUBRICANTS

AMERILUBE ADVANCED TECHNOLOGY LUBRICANTS COMPRESSOR LUBRICANTS COMPRESSOR LUBRICANTS AMERICAN SYNTHOL, INC. 2930 MOUNTAIN TRACE, ROSWELL, GA 30075 PHONE: 800-633-5457 / FAX: 888-731-9534 SERIES DE COMPRESSOR FLUIDS AMERILUBE SERIES DE AMERILUBE SERIES DE compressor

More information

BFK Bi-flow Filter Drier

BFK Bi-flow Filter Drier ALCO is a hermetic Bi-flow filter-drier in solid block style for use on liquid line in reversible refrigeration systems such as heat pump units. Features Solid block style Integrated check valves insure

More information

No Infrared Refrigerant Leak Detector

No Infrared Refrigerant Leak Detector No. 22791 Infrared Refrigerant Leak Detector Operator s Manual Product Description The Robinair No. 22791 uses infrared optics to create a refrigerant leak detector that combines sensitivity, speed, battery

More information

Program IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT

Program IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT Performance A/C International A N AV I S TA R C O M PA N Y Program IV: ProStar TM Study Guide TMT-160701 Series Study Guide Performance A/C Program IV: International ProStar Series TMT-160701 2007 International

More information

US PETROLON. LUBRICATION & FILTRATION CATALOG

US PETROLON. LUBRICATION & FILTRATION CATALOG US PETROLON LUBRICATION & FILTRATION CATALOG wwwuspetroloncom 2 US PETROLON INDUSTRIAL about us IMPROVING MACHINERY LIFE WITH SPECIALTY LUBRICANTS AND FILTRATION 447 n 66th unit 3 lincoln, ne 68505 phone

More information

Steam Turbines & Boiler Feed Pumps

Steam Turbines & Boiler Feed Pumps Suffering points Keep equipment up & running wit Operators at coal-fired power plants must keep all of their equipment operating as efficiently as possible under harsh conditions such as high operating

More information

INSTRUCTION MANUAL. Xfinity Enpro 12 Top Discharge Outdoor unit 31VA Series.

INSTRUCTION MANUAL. Xfinity Enpro 12 Top Discharge Outdoor unit 31VA Series. Xfinity Enpro 12 Top Discharge Outdoor unit 31VA Series INSTRUCTION MANUAL WARNING! Read and follow all safety precautions in Instruction Manual - improper use can cause serious injury. www.delta-dct.com

More information

Steam Turbines & Boiler Feed Pumps

Steam Turbines & Boiler Feed Pumps Suffering points Keep equipment up & running wit Operators at coal-fired power plants must keep all of their equipment operating as efficiently as possible under harsh conditions such as high operating

More information

Think Differently: Prevent Ammonia Compressor Failures

Think Differently: Prevent Ammonia Compressor Failures Think Differently: Prevent Ammonia Compressor Failures Ammonia Compressors are critical machines in the Food and Beverage Industry where the chilling or freezing of products is a requirement PREVENT AMMONIA

More information

SCROLL COMPRESSORS. SF 1-6 ( kw/2-7.5 hp) / SF ( kw/3-30 hp)

SCROLL COMPRESSORS. SF 1-6 ( kw/2-7.5 hp) / SF ( kw/3-30 hp) SCROLL COMPRESSORS SF 1-6 (1.5-5.5 kw/2-7.5 hp) / SF + 2-22 (2.2-22 kw/3-30 hp) COST-EFFICIENT, HIGH-QUALITY AIR With its state-of-the-art oil-free compressor technologies such as screw, tooth, centrifugal,

More information

Reassess your Pump Startup (S/U) and Shutdown (S/D) Procedures By Heinz P. Bloch For TECÉM tecem.com.br Oct,05,2013

Reassess your Pump Startup (S/U) and Shutdown (S/D) Procedures By Heinz P. Bloch For TECÉM tecem.com.br Oct,05,2013 Reassess your Pump Startup (S/U) and Shutdown (S/D) Procedures By Heinz P. Bloch For TECÉM tecem.com.br Oct,05,2013 It may sound far-fetched, but the ramifications of incorrect pump S/U and S/D procedures

More information

VACUUM AND CHARGING HOSES

VACUUM AND CHARGING HOSES VACUUM AND HOSES RECOVERY YELLOW JACKET HVAC&R VACUUM SUPEREVAC AND HOSES YELLOW JACKET PLUS II Charging Hoses Double barrier protection for CFC, HCFC and HFC refrigerants 20 EDITION 62 CATALOG RECOVERY

More information

Technical brochure Eliminator filter drier DCR - with replaceable solid core

Technical brochure Eliminator filter drier DCR - with replaceable solid core MAKING MODERN LIVING POSSIBLE Technical brochure Eliminator filter drier DCR - with replaceable solid core www.danfoss.com Contents Page Introduction...3 Features...3 Approvals...3 Technical data...4 of

More information

A/C - Retrofitting R-12 to R-134a File In Section: 1 - HVAC

A/C - Retrofitting R-12 to R-134a File In Section: 1 - HVAC 1984 Cadillac Full Size Cad RWD V8-252 4.1L Page 1 Technical Service Bulletin # 431207E Date: 970101 A/C - Retrofitting R-12 to R-134a File In Section: 1 - HVAC Bulletin No.: 43-12-07E Date: January, 1997

More information

MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS

MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS SPORTS & SAFETY 2 MINI-VERTICUS & VERTICUS BAUER KOMPRESSOREN MINI-VERTICUS & VERTICUS STATIONARY COMPRESSORS REINVENTED

More information

ELIMINATOR Hermetic filter drier Types DML and DCL

ELIMINATOR Hermetic filter drier Types DML and DCL MAKING MODERN LIVING POSSIBLE Data sheet ELIMINATOR Hermetic filter drier Types DML and DCL All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types

More information

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in

More information

Company Profile & Presentation

Company Profile & Presentation LOGO Company Profile & Presentation www.fuoo.net Tel/Fax: 0086 23 8823 9845 Mob/WhatsApp: 0086 135 2739 0908 Add: No.5 Hongshi Street, Jiulongpo District, Chongqing, China WHO WE ARE Fuootech Oil Filtration

More information

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS Compressed Air Filters 15-1600 scfm FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES Z E K S Z T F C O M P R E S S E D A I R F I

More information

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information Section 3.2 Machine Maintenance - Hydraulic Oil and Tank Information Hydraulic Oil Tank: Hydraulic Tank Oil Level... 3.2.2 Sight Gauge... 3.2.2 Warning Lights... 3.2.2 Hydraulic Oil Tank Pressurizing System...

More information

CHAPTER 12 SERVICING. Section Title Page

CHAPTER 12 SERVICING. Section Title Page CHAPTER 12 SERVICING Section Title Page 12-10 Main Rotor Gearbox.................................. 12.1 12-11 Servicing................................. 12.1 12-12 Filter Replacement...........................

More information

Emerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc.

Emerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc. Emerging Oil Free Technologies Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc. rgood@danfoss.com 1 Agenda Chiller Overview Benefits of Oil Free Oil Free Compressors

More information

Product Information. UCON Compressor Lubricant RSC-155 for Rotary Screw Compressors

Product Information. UCON Compressor Lubricant RSC-155 for Rotary Screw Compressors Product Information 8&21Ã)OXLGVÃÉÃ/XEULFDQWV UCON Compressor Lubricant RSC-155 for Rotary Screw Compressors 3URGXFW 'HVFULSWLRQ )HDWXUHVÃDQG %HQHILWV UCON Compressor Lubricant RSC-155 is a high performance

More information

Copeland Screw TM Compressors

Copeland Screw TM Compressors Copeland Screw TM Compressors Mechanical Guidelines for SHL & SHM Models using ESC-201 Control System Contents: Start-Up Procedure Operating Specifications Maintenance Trouble Shooting Guidelines Start-up

More information

9/28/2018. Refrigeration compressor operation, maintenance and safety

9/28/2018. Refrigeration compressor operation, maintenance and safety Refrigeration compressor operation, maintenance and safety Presented By: Dhananjay S. Deshpande Company name: Technex HVAC&R Engg. Works 304, Shivshakti CHS, Sector 09, Plot no 15, Khanda colony, New Panvel

More information

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS Nano Nano 2 Nano Hybrid ITECH Creative Technology INDEX 1 INTRODUCTION... 2 1.1 Safety instructions... 2 2 EQUIPMENT... 2 3 USE... 4 3.1 Control panel...

More information

High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2

High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2 High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15120A/15122A Manuel del Operador... 8 Pompe à Vide à Haut Rendement Modèle 15120A/15122A

More information

Engine Liquid Filtration

Engine Liquid Filtration Engine Liquid Filtration Lube/Oil, Fuel, Coolant, Hydraulic and Transmission Since 1915, we have delivered innovative filtration solutions that protect engine components to extend the life of your equipment.

More information

DIM Heating and Air Conditioning

DIM Heating and Air Conditioning 2014 NATEF JOB TASKS COMPLETION REQUIREMENT: P1-95% P2-70% P3-25% Student Name: DETAILED COURSE CONTENT VI. HEATING, VENTILATION, & AIR CONDITIONING A. HVAC SYSTEMS -- The student will be able to: P1 P2

More information

Secondary Coolant 301

Secondary Coolant 301 Secondary Coolant 301 Instructor Rusty Walker Hill PHOENIX Learning Center Secondary Coolant 301 Start-Up Procedures Secondary Coolant 301 Objectives Describe the initial startup procedures for a medium

More information

DS V1. Rig Compressors. The most trusted brand in water-well drilling industry Rugged and Reliable

DS V1. Rig Compressors. The most trusted brand in water-well drilling industry Rugged and Reliable DS 1200-350 V1 Rig Compressors The most trusted brand in water-well drilling industry Rugged and Reliable A TRADITION OF RELIABILITY ELGi is a 50+ year-old company raised to become one of the world s largest

More information

MACHINES RECOVERY. 99 Washington Street Melrose, MA Phone Toll Free SYSTEMS SUPEREVAC

MACHINES RECOVERY. 99 Washington Street Melrose, MA Phone Toll Free SYSTEMS SUPEREVAC 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY SUPEREVAC HOSES 29 RECOVERY HOSES 1/4" 4-IN-1 BALL VALVE TOOL For vacuum,

More information

BG Diesel Fuel Products THE PROOF

BG Diesel Fuel Products THE PROOF BG Diesel Fuel Products THE PROOF Field Test Metropolitan Atlanta Rapid Transit Authority BG DFC with Lubricity, Part No. 227, stopped accelerated corrosion that was occurring in underground fuel storage

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

SHELL NATURELLE CHANGEOVER ADVICE

SHELL NATURELLE CHANGEOVER ADVICE SHELL NATURELLE CHANGEOVER ADVICE Bulletin, 1 January 2018 This bulletin is issued to all customer vessels and shore-based staff to help manage and plan the conversion to the Shell Naturelle range of lubricants.

More information

Storage connection with 5 meter long rubber hose DN8, DILO coupling DN8, ball valve DN R050 and five different SF 6

Storage connection with 5 meter long rubber hose DN8, DILO coupling DN8, ball valve DN R050 and five different SF 6 For liquid SF 6 storage B095R12 Compressor unit Operating voltage: 220-240 V / 50-60 Hz alternating current B095R12S15 Compressor unit Operating voltage: 110-127 V / 50-60 Hz alternating current Dimensions:

More information

ELIMINATOR Hermetic filter drier Types DCL and DML

ELIMINATOR Hermetic filter drier Types DCL and DML Data sheet ELIMINATOR Hermetic filter drier s DCL and DML All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers

More information

Design Parameters. System Equipment

Design Parameters. System Equipment / Air System Cargo Container NES 09-205 NES was selected to fabricate an integrated /Air remediation system for an active airport in New England where extensive jet fuel contamination was present. The

More information

Essentials encapsulated 3-20 HP

Essentials encapsulated 3-20 HP Encap Series Screw Air Compressors Essentials encapsulated 3-20 HP Elgi, established in 1960, designs and manufactures a wide range of compressors. The company has gained its reputation for design and

More information

Introduction to Hydraulic Filtration

Introduction to Hydraulic Filtration sales@nationalfiltersinc.com * www.nationalfilters.com 360 Industrial Parkway * Harbor Beach, MI USA * 48441 TF: 1-888-797-3275 * Tel: 989-479-3273 * Fax: 989-479-3251 1 What is Fluid Power? Fluid power

More information

YMC 2 Chiller: The new standard in chiller technology

YMC 2 Chiller: The new standard in chiller technology YORK YMC 2 Chiller: The new standard in chiller technology YORK YMC 2 chiller, a perfect example of how far Johnson Controls has advanced chiller technology The YMC 2 sets a new standard in chiller technology.

More information

SUBJECT: -Used Lubricant Oil (U L O) Re Refining Technology.

SUBJECT: -Used Lubricant Oil (U L O) Re Refining Technology. SUBJECT: -Used Lubricant Oil (U L O) Re Refining Technology. Coroney Technologies is recognised for its Invention of filter VACULIFE TM (US patent No: - US 8,628,607 B2) which protects vacuum pumps & systems

More information

Ohio Specific Universal Waste

Ohio Specific Universal Waste Ohio Specific Universal Waste December 21, 2017 Three new universal waste rules become effective specifically within the confines of the State of Ohio Antifreeze Non empty Aerosol Containers Paint and

More information

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) MAKING MODERN LIVING POSSIBLE Data sheet Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) A CPCE hot gas bypass regulator is used to adapt compressor capacity to actual evaporator

More information

EMERSON CLIMATE TECHNOLOGIES

EMERSON CLIMATE TECHNOLOGIES STAS STEEL TAKE-APART FILTER DRIER APPLICATION Replaceable core filter-drier for CFC, HCFC and HFC refrigerants for use in large commercial air conditioning and refrigeration systems. FEATURES Unique internal

More information

IT SIMPLY WORKS. WARRANTY LINE. // Products and accessories for A/C and cooling systems

IT SIMPLY WORKS. WARRANTY LINE. // Products and accessories for A/C and cooling systems IT SIMPLY WORKS. WARRANTY LINE // Products and accessories for A/C and cooling systems 2 IT SIMPLY WORKS. WE GUARANTEE THAT WITH OUR PRODUCTS YOUR STATION WILL PERFORM ITS BEST EVERYDAY. A/C compressor

More information

Call the A/C Experts SD Compressor Service Guide

Call the A/C Experts SD Compressor Service Guide Call the A/C Experts SD Compressor Service Guide Table of Contents 1. Compressor Models Covered 2. Compressor Nomenclature 3. Cautionary Information 3.1 Pressure Release 3.2 Recovery of Refrigerant 3.3

More information

AFTERSALES BULLETIN FROM THE PARTS & SERVICE DIVISION

AFTERSALES BULLETIN FROM THE PARTS & SERVICE DIVISION AFTERSALES BULLETIN FROM THE PARTS & SERVICE DIVISION Date 02/10/2015 Ref 12/2015 INTERNAL DISTRIBUTION TO BE CARRIED OUT BY THE DEALERSHIP PSA APPROVED R-1234YF AIR CONDITIONING CHARGING STATIONS With

More information