1 Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60 Hz) 10HX thru 55HX 10 thru 52 Nominal Tons PC HX-2006-R0
2 Contents Page Features 3-4 Rating and Selection 5 Performance Table (50 Hz Scroll Compressor) 6 Performance Table (60 Hz Scroll Compressor) 7 Performance Table (50 Hz Reciprocating Compressor) 8 Performance Table (60 Hz Reciprocating Compressor) 9 Capacity Chart (50 Hz) Capacity Chart (60 Hz) Physical Data (50 Hz Scroll Compressor) 32 Physical Data (60 Hz Scroll Compressor) 33 Physical Data (50 Hz Reciprocating Compressor) 34 Physical Data (60 Hz Reciprocating Compressor) 35 Electrical Data (50 & 60 Hz Scroll Compressor) 36 Electrical Data (50 & 60 Hz Reciprocating Compressor) 37 Dimensions Weight Distribution (Scroll Compressor) 40 Weight Distribution (Reciprocating Compressor) 41 Guide Specifications 42 Model Nomenclature 43 ROYAL TEMP's concern. PRESERVING THE ENVIRONMENT The discovery of hole in the earth's ozone layer over Antarctica in 19 led the movement to reduce the use of CFC's or chlorofluorocarbons. CFC's are having high ozone depleting potential. HCFC's are also containing some ozone depleting potential and are scheduled to be banned on Being responsible in preserving the environment, you have the right choice of choosing ROYAL TEMP's Air Cooled Condensing Unit Series HX employing R-134A as refrigerant because R-134A is an HFC (chlorine-free) refrigerant with a low ozone depleting potential and direct global warming potential. R-134A refrigerant is not affected by the Montreal Protocol on substance that depletes ozone layer. 2
3 Easy to Access Components More Efficient Air Cooled Condensers Easy to Install and Maintain Preserving the Environment GENERAL Royal Temp HX Series Air Cooled Condensing Units are factory fabricated and assembled comprising of compressors, condenser fans and motors, high efficiency condenser coils, and electrical control box. UNIT CONSTRUCTION These types of RCD Air Cooled Condensing Units are simple, with small footprint, easy to install and maintain due to ease of components accessibility. It features side intake and vertical top discharge. A weatherproof electrical cabinet is provided to protect the electrical components. The unit base provides sturdy foundation and simplified installation. COMPRESSOR Units are provided with hermetic scroll compressors or semi-hermetic reciprocating compressors. The compressor motor is equipped with thermal overload protection. FAN AND MOTOR Fans are propeller type and made up of aluminum blades rigidly fastened to steel hub. The multi-blade fans are individually driven and directly coupled to motor. The fans are statically and dynamically balanced and are protected by epoxy coated fan guard. The motors are equipped with inherent thermal overload protection and permanently lubricated bearings. Motors are air over type. CONTROL Pre-wired controls include operational and safety control devices such as contactors, high and low pressure switches. REFRIGERANT CIRCUIT Each refrigerant circuit's liquid and suction lines are provided with isolation valve thereby allowing the refrigerant charge to be stored in the condensing unit and allowing the interconnecting pipes to be isolated. COIL Condenser coils are constructed with enhanced copper tubes mechanically bonded to aluminum fins having self spacing collar. The coil assembly frame is made up of galvanized steel sheet. Sub-cooling circuits are provided integral to condenser coil to provide refrigerant effect and eliminate flash gas affecting the capacity of the unit. The brazed joints and the possibility of refrigerant loss are reduced due to mechanically U-formed tubes compared to a plate finned coil with brazed return bends. The coil assembly is pressure tested to 400psig while submerged to warm water. 3
4 STANDARD FEATURES & ACCESSORIES Components can be easily access and easy to maintain. Small footprint that requires less space for installation. Low vibration design and reduced sound level. Copper tubes - aluminum fins condenser coil construction Equipped with liquid and suction line isolating valves Filter drier (supplied loose) Fan cycling switch, low and high pressure switches Across The Line (ATL) start Aluminum condenser fan blade OPTIONAL FEATURES AND ACCESSORIES LONG LIFE COIL are available with the following options; Copper tubes-aluminum fins with Phenolic coating (P-COAT ) Copper tubes-copper fins (CuT-CuF ) Copper tubes-copper fins electro-tinned after fabrication (ET-COAT ) Compressor & condenser fan motor circuit breakers Condenser coil guard Hail guard Air inlet grille Filter drier isolation valve Suction and discharge mufflers Suction and discharge vibration eliminator for scroll, suction vibration eliminator for semi-hermetic reciprocating Liquid line solenoid valve Liquid-moisture indicator or sight glass Pressure gages Voltage / Phase reversal monitor Volt free contacts for remote indication (status and fault) Liquid receiver Condenser coil end panels for aesthetic-finished appearance (42HX and 55HX) Compressor anti-recycling timer (if unit is to be controlled by DDC) 4
5 RATINGS AND SELECTION Royal Temp RCD Air Cooled Condensing Units may be used with air handling units, direct expansion coils in built up systems, remote mounted water chillers with numerous other evaporator units. Capacity ratings as shown in tables and charts are for R-134a refrigerant. Ratings shown are at saturated suction temperatures at the compressor. In actual practice, suction line pressure drop reduces the compressor capacity and compressor must operate at a lower suction pressure to maintain the desired evaporator temperature. It is usually standard practice to size the suction line for a maximum pressure drop of 3 PSIG which corresponds to 2 F. Therefore, the evaporator will operate at an approximately 2 F above the compressor suction temperature and this should be taken into consideration when selecting evaporator. SELECTION PROCEDURE The following conditions are needed to select Royal Temp RCD Air Cooled Condensing Units. Total cooling load (BTUH) Air temperature entering condenser ( F) Evaporator temperature ( F) SAMPLE SELECTION #1 (Condensing Unit matched with Royal Temp ATX Air Handling Unit) Given: Total cooling load: 410,796 BTUH = 411 MBH Air temp. entering cond.: F Evaporator temp.: 40 F to 50 F Suction line loss: 2 F Find: Air Cooled Condensing Unit Model Suction temperature at compressor and evaporator temperature at which the condensing unit and evaporating unit will balance with suction line loss considered. Solution: Referring to Performance Table it is found that model 35HX has the capacity to meet cooling load requirement. Provided that at arbitrary evaporator refrigerant temperatures of 40 F and 50 F the capacities are MBH and MBH respectively. Plot the above total capacities on the 35HX condensing unit capacity chart as shown in the figure. Draw a straight line from A to B establishing the evaporator coil capacity line. Take suction line loss into consideration, move horizontally left 2 F from points A and B and establish points C and D. Draw a straight line from point C to point D establishing system capacity line. Capacity, MBH From the system capacity line CD determine the balanced conditions as follows: At the intersection of the system capacity line and the F ambient air draw a line horizontally to the left and read capacity as MBH. From same intersection point draw line vertically down to suction temperature line and read the suction temperature at compressor as 40.4 F. From same intersection point draw line horizontally to the right to evaporator capacity line AB and establish an intersection point. From this intersection point draw line vertically down to suction temperature line and read the evaporator temperature as 42.4 F HX C A 40.4 Ambient temperature, F Suction Temperature, F Using Performance Table and interpolating between 40 F and 45 F suction temperatures, the KW input at 40.4 F is kw. SAMPLE SELECTION #2 (Typical Evaporator) Given: Total cooling load: 214,000 BTUH = 214 MBH Air temp. entering cond.: F Evaporator temp.: 47 F Suction line loss: 2 F Find: Air Cooled Condensing Unit Model Suction temperature at compressor Solution: Examination of the condensing unit capacity data contained in the table quickly determines that a model 18HX appears to have the capacity to meet the requirements. Referring to Performance Table, it can be determined that 18HX will produce the required capacity of MBH at compressor suction temperature of 45 F (taking into consideration 2 F suction line loss) and F air temperature entering condenser. D B 5
6 PERFORMANCE TABLE (SCROLL, 50Hz) MODEL 10HX 12HX 15HX 18HX 22HX 25HX 30HX 35HX 42HX 48HX 55HX AIR TEMPERATURE ( F) SST CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT NOTES Interpolation is permissible. Do not extrapolate. KW input is for compressor only. LEGENDS SST - Saturated suction temperature ( F) CAP - Capacity in MBH (1000 Btuh) KW - Compressor motor power input SCT - Saturated condensing temperature ( F) 6
7 PERFORMANCE TABLE (SCROLL, 60Hz) MODEL 10HX 12HX 15HX 18HX 22HX 25HX 30HX 35HX 42HX 48HX 55HX AIR TEMPERATURE ( F) SST CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT NOTES Interpolation is permissible. Do not extrapolate. KW input is for compressor only. LEGENDS SST - Saturated suction temperature ( F) CAP - Capacity in MBH (1000 Btuh) KW - Compressor motor power input SCT - Saturated condensing temperature ( F) 7
8 PERFORMANCE TABLE (RECIPROCATING, 50Hz) MODEL 10HX 12HX 15HX 18HX 22HX 25HX 30HX 35HX 42HX 48HX 55HX AIR TEMPERATURE ( F) SST CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT NOTES Interpolation is permissible. Do not extrapolate. KW input is for compressor only. LEGENDS SST - Saturated suction temperature ( F) CAP - Capacity in MBH (1000 Btuh) KW - Compressor motor power input SCT - Saturated condensing temperature ( F) 8
9 PERFORMANCE TABLE (RECIPROCATING, 60Hz) MODEL 10HX 12HX 15HX 18HX 22HX 25HX 30HX 35HX 42HX 48HX 55HX AIR TEMPERATURE ( F) SST CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT CAP KW SCT NOTES Interpolation is permissible. Do not extrapolate. KW input is for compressor only. LEGENDS SST - Saturated suction temperature ( F), corresponds to the pressure at the compressor suction. CAP - Capacity in MBH (1000 Btuh) KW - Compressor motor power input SCT - Saturated condensing temperature ( F) 9
10 CAPACITY CHART (50Hz) CAPACITY CHART 10HX SCROLL, 50HZ CAPACITY CHART 10HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 10
11 CAPACITY CHART (50Hz) CAPACITY CHART 12HX SCROLL, 50HZ CAPACITY CHART 12HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 11
12 CAPACITY CHART (50Hz) CAPACITY CHART 15HX SCROLL, 50HZ CAPACITY, MBH CAPACITY CHART 15HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 12
13 CAPACITY CHART (50Hz) CAPACITY CHART 18HX SCROLL, 50HZ CAPACITY CHART 18HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 13
14 CAPACITY CHART (50Hz) CAPACITY CHART 22HX SCROLL, 50HZ CAPACITY CHART 22HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 14
15 CAPACITY CHART (50Hz) CAPACITY CHART 25HX SCROLL, 50HZ CAPACITY CHART 25HX RECIPROCATING, 50HZ CAPACITY, MBH Air Cooled Condensing Unit 15
16 CAPACITY CHART (50Hz) CAPACITY CHART 30HX SCROLL, 50HZ CAPACITY CHART 30HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 16
17 CAPACITY CHART (50Hz) CAPACITY CHART 35HX SCROLL, 50HZ CAPACITY, MBH CAPACITY CHART 35HX RECIPROCATING, 50HZ CAPACITY, MBH Air Cooled Condensing Unit 17
18 CAPACITY CHART (50 Hz) CAPACITY CHART 42HX SCROLL, 50HZ CAPACITY CHART 42HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 18
19 CAPACITY CHART (50 Hz) 1 CAPACITY CHART 48HX SCROLL, 50HZ CAPACITY, MBH CAPACITY CHART 48HX RECIPROCATING, 50HZ CAPACITY, MBH Air Cooled Condensing Unit 19
20 CAPACITY CHART (50 Hz) 1 CAPACITY CHART 55HX SCROLL, 50HZ CAPACITY CHART 55HX RECIPROCATING, 50HZ Air Cooled Condensing Unit 20
21 CAPACITY CHART (60Hz) CAPACITY CHART 10HX SCROLL, 60HZ CAPACITY CHART 10HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 21
22 CAPACITY CHART (60Hz) CAPACITY CHART 12HX SCROLL, 60HZ CAPACITY CHART 12HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 22
23 CAPACITY CHART (60Hz) CAPACITY CHART 15HX SCROLL, 60HZ 50.0 CAPACITY CHART 15HX RECIPROCATING, 60HZ 50.0 Air Cooled Condensing Unit 23
24 CAPACITY CHART (60Hz) CAPACITY CHART 18HX SCROLL, 60HZ CAPACITY CHART 18HX RECIPROCATING, 60HZ 50.0 Air Cooled Condensing Unit 24
25 CAPACITY CHART (60Hz) CAPACITY CHART 22HX SCROLL, 60HZ CAPACITY CHART 22HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 25
26 CAPACITY CHART (60Hz) CAPACITY CHART 25HX SCROLL, 60HZ CAPACITY CHART 25HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 26
27 CAPACITY CHART (60Hz) CAPACITY CHART 30HX SCROLL, 60HZ CAPACITY CHART 30HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 27
28 CAPACITY CHART (60Hz) CAPACITY CHART 35HX SCROLL, 60HZ CAPACITY, MBH CAPACITY CHART 35HX RECIPROCATING, 60HZ CAPACITY, MBH Air Cooled Condensing Unit 28
29 CAPACITY CHART (60 Hz) 1 CAPACITY CHART 42HX SCROLL, 60HZ CAPACITY CHART 42HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 29
30 CAPACITY CHART (60 Hz) 1 CAPACITY CHART 48HX SCROLL, 60HZ 1 CAPACITY, MBH CAPACITY CHART 48HX RECIPROCATING, 60HZ 1 CAPACITY, MBH Air Cooled Condensing Unit 30
31 CAPACITY CHART (60 Hz) CAPACITY CHART 55HX SCROLL, 60HZ CAPACITY CHART 55HX RECIPROCATING, 60HZ Air Cooled Condensing Unit 31
32 PHYSICAL DATA (SCROLL, 50 Hz) 10HX - 25HX Size 10HX 12HX 15HX 18HX 22HX 25HX Refrigerant R-134a Compressor Hermetic Scroll Quantity Oil charge, liters 4.1/ / / / / /4.7 Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 30HX - 55HX Size 30HX 35HX 42HX 48HX 55HX Refrigerant R-134a Compressor Hermetic Scroll Quantity Oil charge, liters 4.7/ /4.1/4.1/ /4.1/4.1/ /4.1/4.7/ /4.7/4.7/4.7 Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 32
33 PHYSICAL DATA (SCROLL, 60 Hz) 10HX - 25HX Size 10HX 12HX 15HX 18HX 22HX 25HX Refrigerant R-134a Compressor Hermetic Scroll Quantity Oil charge, liters 4.1/ / / / / /4.7 Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 30HX - 55HX Size 30HX 35HX 42HX 48HX 55HX Refrigerant R-134a Compressor Hermetic Scroll Quantity Oil charge, liters 4.7/ /4.1/4.1/ /4.1/4.1/ /4.1/4.7/ /4.7/4.7/4.7 Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 33
34 PHYSICAL DATA (RECIPROCATING, 50 Hz) 10HX - 25HX Size 10HX 12HX 15HX 18HX 22HX 25HX Refrigerant R-134a Compressor Semi-hermetic Reciprocating Quantity Oil charge, liters Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 30HX - 55HX Size 30HX 35HX 42HX 48HX 55HX Refrigerant R-134a Compressor Semi-hermetic Reciprocating Quantity Oil charge, liters / / / /4.9 Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 34
35 PHYSICAL DATA (RECIPROCATING 60 Hz) 10HX - 25HX Size 10HX 12HX 15HX 18HX 22HX 25HX Refrigerant R-134a Compressor Semi-hermetic Reciprocating Quantity Oil charge, liters Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 30HX - 55HX Size 30HX 35HX 42HX 48HX 55HX Refrigerant R-134a Compressor Semi-hermetic Reciprocating Quantity Oil charge, liters / / / /4.9 Condenser Coil Copper tubes - aluminum fins Tube diameter, in. 3/8 3/8 3/8 3/8 3/8 Total face area, ft² Airflow Condenser fan diameter, in Condenser fan motor HP Quantity Approx. shipping weight, kg Approx. operating weight, kg Note: Unit is shipped with holding charge only. 35
36 ELECTRICAL DATA (SCROLL COMPRESSOR, 50 & 60Hz) Model 10HX 12HX 15HX 18HX 22HX 25HX 30HX 35HX 42HX 48HX 55HX Power Supply Compressor Condenser Fan Motor Circuit #1 Circuit #2 FLA LRA FLA LRA FLA QTY 230 / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / 60 2 x 50 2 x x 50 2 x / 3 / 60 2 x 32 2 x 1 2 x 32 2 x / 3 / 60 2 x 27 2 x x 27 2 x / 3 / 50 2 x 27 2 x x 27 2 x / 3 / 60 2 x 57 2 x x 57 2 x / 3 / 60 2 x 39 2 x x 39 2 x / 3 / 60 2 x 32 2 x x 32 2 x / 3 / 50 2 x 32 2 x x 32 2 x / 3 / 60 2 x 57 2 x x 81 2 x / 3 / 60 2 x 39 2 x x 48 2 x / 3 / 60 2 x 32 2 x x 41 2 x / 3 / 50 2 x 32 2 x x 41 2 x / 3 / 60 2 x 81 2 x x 81 2 x / 3 / 60 2 x 48 2 x x 48 2 x / 3 / 60 2 x 41 2 x x 41 2 x / 3 / 50 2 x 41 2 x x 41 2 x MCA MOCP NOTES 1. MCA is based on % of the rated load amperes of the largest motor plus 100% of the rated load amperes of the rest of the motors. 2. MOCP is based on 225% of the rated load ampere of the largest motor plus 100% of the rated load amperes of the rest of the motors. 3. Use copper wire only. LEGENDS FLA Full Load Amp LRA Locked Rotor Amp MCA Minimum Circuit Ampacity MOCP Maximum OverCurrent Protection 36
37 ELECTRICAL DATA (RECIPROCATING COMPRESSOR, 50 & 60Hz) Model 10HX 12HX 15HX 18HX 22HX 25HX 30HX 35HX 42HX 48HX 55HX Power Supply Compressor Condenser Fan Motor Circuit #1 Circuit #2 FLA LRA FLA LRA FLA QTY 230 / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / / 3 / MCA MOCP NOTES 1. MCA is based on % of the rated load amperes of the largest motor plus 100% of the rated load amperes of the rest of the motors. 2. MOCP is based on 225% of the rated load ampere of the largest motor plus 100% of the rated load amperes of the rest of the motors. 3. Use copper wire only. LEGENDS FLA Full Load Amp LRA Locked Rotor Amp MCA Minimum Circuit Ampacity MOCP Maximum OverCurrent Protection 37
38 DIMENSIONAL DATA P L A N SUCTION LINE CONN. LIQUID LINE CONN. SCROLL COMPRESSOR MODEL L W H SUCTION CONN., IN. LIQUID CONN., IN. COMPRESSOR ACCESS AIR IN 10HX /8 x 2 5/8 x 2 12HX /8 x 2 5/8 x 2 15HX /8 x 2 5/8 x 2 18HX /8 x 2 5/8 x 2 COMPRESSOR ACCESS RECIPROCATING COMPRESSOR ELECTRICAL AND CONTROL CABINET MODEL L W H SUCTION CONN., IN. LIQUID CONN., IN. FRONT ELEVATION AIR OUT 10HX /8 7/8 12HX /8 7/8 15HX /8 7/8 AIR IN 18HX /8 7/8 NOTES CABLE ENTRY 1. All dimensions in mm unless otherwise specified. 2. Unit must have the following minimum clearance for airflow: TOP Do not restrict. ENDS 1219 mm (4 ft) LEFT SIDE 914 mm (3 ft) RIGHT SIDE (AIR INLET) 1524 mm (5 ft) P L A N COMPRESSOR ACCESS SUCTION LINE CONN. SUCTION LINE CONN. LIQUID LINE CONN. LIQUID LINE CONN. SCROLL COMPRESSOR MODEL L W H SUCTION CONN., IN. LIQUID CONN., IN. 22HX /8 x 2 7/8 x 2 25HX /8 x 2 7/8 x 2 AIR IN AIR IN RECIPROCATING COMPRESSOR ELECTRICAL AND CONTROL CABINET MODEL L W H SUCTION CONN., IN. (3) LIQUID CONN., IN. (3) FRONT ELEVATION AIR OUT 22HX /8 1-1/8 25HX /8 1-1/8 NOTES 1. All dimensions in mm unless otherwise specified. 2. Unit must have the following minimum clearance for airflow: TOP Do not restrict. ENDS 1219 mm (4 ft) LEFT SIDE 1524 mm (5 ft) RIGHT SIDE (AIR INLET) 1524 mm (5 ft) 3. For units with single reciprocating compressor, one suction and liquid line connection is provided on the left side of the unit. AIR IN CABLE ENTRY AIR IN 38
39 DIMENSIONAL DATA COMPRESSOR ACCESS SCROLL COMPRESSOR SUCTION LINE CONN. LIQUID LINE CONN. SUCTION LINE CONN. LIQUID LINE CONN. MODEL L W H SUCTION CONN., IN. LIQUID CONN., IN. P L A N 30HX /8 x 2 7/8 x 2 35HX /8 x 2 1-1/8 x 2 RECIPROCATING COMPRESSOR AIR IN AIR IN MODEL L W H SUCTION CONN., IN. (3) LIQUID CONN., IN. (3) 30HX /8 1-1/8 35HX /8 x 2 1-1/8 x 2 FRONT ELEVATION ELECTRICAL AND CONTROL CABINET AIR OUT NOTES 1. All dimensions in mm unless otherwise specified. 2. Unit must have the following minimum clearance for airflow: TOP Do not restrict. ENDS 1219 mm (4 ft) LEFT SIDE 1524 mm (5 ft) RIGHT SIDE (AIR INLET) 1524 mm (5 ft) 3. For units with single reciprocating compressor, one suction and liquid line connection is provided on the left side of the unit. AIR IN AIR IN CABLE ENTRY SUCTION LINE CONN. LIQUID LINE CONN. SUCTION LINE CONN. LIQUID LINE CONN. P L A N SCROLL COMPRESSOR AIR IN AIR IN MODEL L W H SUCTION CONN., IN. LIQUID CONN., IN. 42HX /8 x 2 1-1/8 x 2 48HX /8 x 2 1-1/8 x 2 55HX /8 x 2 1-1/8 x 2 FRONT ELEVATION CABLE ENTRY ELECTRICAL AND CONTROL CABINET AIR OUT RECIPROCATING COMPRESSOR MODEL L W H SUCTION CONN., IN. (3) LIQUID CONN., IN. (3) 42HX /8 x 2 1-1/8 x 2 48HX /8 x 2 1-1/8 x 2 55HX /8 x 2 1-1/8 x 2 AIR IN AIR IN NOTES 1. All dimensions in mm unless otherwise specified. 2. Unit must have the following minimum clearance for airflow: TOP Do not restrict. ENDS 1219 mm (4 ft) LEFT SIDE 1524 mm (5 ft) RIGHT SIDE (AIR INLET) 1524 mm (5 ft) 3. For units with single reciprocating compressor, one suction and liquid line connection is provided on the left side of the unit. 39
40 WEIGHT DISTRIBUTION (SCROLL COMPRESSOR) MM DIAMETER HOLE (TYP.) MODEL L W POINT LOADING, KG HX COIL THIS SIDE 12HX HX HX ELECTRICAL AND CONTROL CABINET THIS SIDE MODEL L W POINT LOADING, KG MM DIAMETER HOLE (TYP.) 22HX HX HX HX COIL THIS SIDE COIL THIS SIDE 42HX HX HX ELECTRICAL AND CONTROL CABINET NOTE: DIMENSION "L" AND "W" ARE IN MILLIMETER. 40
41 WEIGHT DISTRIBUTION (RECIPROCATING COMPRESSOR) MM DIAMETER HOLE (TYP.) MODEL L W POINT LOADING, KG HX COIL THIS SIDE 12HX HX HX ELECTRICAL AND CONTROL CABINET THIS SIDE MODEL L W POINT LOADING, KG MM DIAMETER HOLE (TYP.) 22HX HX HX HX COIL THIS SIDE COIL THIS SIDE 42HX HX HX ELECTRICAL AND CONTROL CABINET NOTE: DIMENSION "L" AND "W" ARE IN MILLIMETER. 41
42 GUIDE SPECIFICATIONS 10-55HX GENERAL 1. Air cooled condensing unit suitable for outdoor, on-the-ground or rooftop installation. Unit shall consist of welded hermetic type scroll compressors, air cooled condenser coil, condenser fan and motor, and electrical box. Unit shall have two independent refrigerant circuits and condenser air shall discharge upward. 2. Unit shall be used to match with air handling units, direct expansion coils in built up systems, remote mounted water chillers and with numerous other evaporator units. 3. Unit shall be rated in accordance with ARI Standard Unit shall be manufactured under ISO 9001 (2000) facility which ensures quality of the product. 5. Unit shall utilize R-134a refrigerant. 6. Unit shall be built in accordance with NEC, ASHRAE, and all applicable national and local codes. EQUIPMENT 1. Unit shall be factory fabricated and assembled comprising of scroll compressors, condenser fans and motors, high efficiency condenser coils, and electrical control box. 2. Units shall contain factory wiring, piping, safety and operational controls. 3. Casing shall be made from galvanized steel, painted, and fully weather-proof suitable for outdoor installation. 4. Independent refrigerant connections, openings for power connections, and removable access panels for servicing shall be provided. 5. Compressor shall be hermetically sealed scroll complete with thermal overload. 6. Condenser fans shall be direct-driven propeller type arranged for vertical discharge. Fans shall be statically and dynamically balanced and shall be provided with safety guards. 7. Condenser coil shall be air cooled, with integral sub-cooling circuits, and shall be constructed with enhanced copper tubes mechanically bonded to aluminum fins having self spacing collar. The coil assembly frame shall be made up of galvanized steel sheet. 8. Factory wired controls shall be housed on a weatherproof cabinet. 9. Each refrigerant circuit's liquid and suction lines shall be provided with isolation valve to allow the refrigerant charge to be stored in the condensing unit and to allow the interconnecting pipes to be isolated. 42
43 MODEL NUMBER NOMENCLATURE RCD - 48 HX S - TWC A N XX Air Cooled Condensing Unit 2 - Unit Size 3 - Unit Series 4 - Compressor Type S Scroll R Reciprocating 5 - Power Supply Across The Line Start: TWC 230V / 3Ph / 60Hz TW7 380V / 3Ph / 60Hz TWD 460V / 3Ph / 60Hz TWR V / 3Ph / 50Hz TF V / 3Ph / 50Hz TWD V / 3Ph / 50Hz 6 - Condenser Coil Fins: A Aluminum, AP Aluminum with Phenolic Coating C Copper, CE Copper Electrotinned 7 - Condenser Coil Protection N None (Standard), CG With Condenser Coil Expanded Mesh HG Hail Guard, AG Air Inlet Grille 8 - Option Code: This letter code (A ZZ) identifies specific features per customer specifications. Consult factory for your specific needs. ROYAL TEMP SAUDI AIR CONTROL SYSTEM P.O. BOX 2625 RIYADH 11461, KSA TEL. No FAX No goldenstar@cyberia.net.sa AGENCY: PC HX R0 Specifications and data are subject to change without prior notice due to continuous product research & development. 43
44 44
DESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationStandard features. Optional features
FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationAIR COOLED CHILLERS WATER COOLED CHILLERS
AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationLUI / LUO. Condensing Units
UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component
More informationStandard features. Optional features
FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationGQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY
TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged
More information1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TABLE OF CONTENTS NOMENCLATURE............................. 3 FEATURES.................................... 4 KV SERIES FEATURES.........................
More informationC O I L M A S T E R CMC-110
CMC-110 TABLE OF CONTENTS OVERVIEW Overview...... 2 Unit Features/Options... 3 Summary of Unit Features.. 4 The Coilmaster Summit line of air-cooled condensers offers the most technologically advanced
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS
(1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TAbLE Of CONTENTs NOMENCLATURE............................. 3 features.................................... 4 KV series features.........................
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationSCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS
SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationengineering guide Air-Cooled Self-Contained Units
engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationSSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON
HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationGP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY
TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More information09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS
09DK-4SB 09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS PERFORMANCE DATA CERTIFIED DIMENSION PRINT 1994 Carrier Corporation Syracuse, New York 13221 Form 09DK-4SB Supersedes 09DK-3SB Printed in U.S.A.
More information30GX AIR-COOLED LIQUID CHILLER
30GX-4SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1997 Carrier Corporation Syracuse, New York 13221 Form 30GX-4SB Supersedes 30GX-3SB Printed in U.S.A. 12-97 Catalog
More informationGQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged
More informationSSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H
PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationManufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER
UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling
More information30GX AIR-COOLED LIQUID CHILLER
30GX-5SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GX-5SB Supersedes 30GX-4SB Printed in U.S.A. 5-98 Catalog No.
More informationNext-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. RU-RFH-1117A Replaces document RU-RFH-0917A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell
More informationNext-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. RU-RFH-0117A Replaces document RU-RFH-0516A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell
More informationR2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz
3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator
More informationSLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw
Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features
More informationGSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h
Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling
More informationTECHNICAL GUIDE. Description PREDATOR SERIES R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS
TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS PREDATOR SERIES YC090-240 and YD120-240 CONDENSING UNIT MODELS PC090-240 and PD180-240 HEAT PUMP UNIT MODELS NC090-240 and
More information38P 60Hz Nominal Cooling Capacity Tons HFC R -410A Refrigerant
38P Condensing Units 60Hz 38P 36K 60K 38P 18K 24K Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationHS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More informationR2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz
R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain
More informationSSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF
High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationC4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT C4A3 SoftSound SX 2300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h
Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationP7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner
TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationProduct Specifications EFFICIENT 13 SEER AIR CONDITIONER
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scrollt compressors on all
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationRGMA Series Package Gas Electric SPECIFICATIONS
RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE
More informationDZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h
Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...
More informationJT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and
More informationCAS. Product Specifications
CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage
More informationAIR-COOLED CONDENSING UNITS
TECHNICAL GUIDE TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS YH-07 thru -25 and YJ-10 thru -20 CONDENSING UNIT MODELS PH-07 thru -20 and PJ-15 thru -20 HEAT PUMP UNIT
More informationAFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.
AFAIR12B Air Conditioners Features Top discharge directs hot air and noise away from the living area Durable Copeland scroll compressor with internal pressure relief valves and inherent thermal protection
More informationCOMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT COMMERCIAL H4A3 DX 1300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationH4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Copeland
More informationJS6BD-K Builder's Series
TECHNICAL SPECIFICATIONS JS6BD-K Builder's Series R-410A High Efficiency Air Conditioner 13 SEER Residential System 2 5 Ton Capacity The JS6BD-K Series now offers the choice of an air conditioner that
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationJT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump
TECHNICAL SPECIFICATIONS JT4BD Series 13 SEER 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump 3, 4, 5 Ton Capacities The JT4BD Series heat pump, when combined with our engineered
More information13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh
PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage
More informationOutreach Innovation Building Penn State Research Park State College, PA. Appendix E. Scroll Chiller Data. The Pennsylvania State University
Outreach Innovation Building Penn State Research Park State College, PA. Appendix E Scroll Chiller Data Kyle Pepperman Mechanical Option The Pennsylvania State University Architectural Engineering Air-Cooled
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS
COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed
More informationR6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY
TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility
More informationProduct Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS
DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier