1 The Water Pump Guy Your Authorized Dealer/Installer for Simple Pump Co Installation and Maintenance of the Hand-Operated Simple Pump THE WATER PUMP GUY PO Box 189 Gardnerville, NV thewaterpumpguy.com

2 TABLE OF CONTENTS Section 1: Introduction Parts Shipped Tools Required 2 Section 2: Do It Yourself, or Call a Professional? 5 Section 3: Inspecting Your Existing System 6 Section 4: Existing Cap Replacement with a Submersible Pump 7 Section 5: Pump Cylinder and Drop Pipe Kit Installation 7 Section 6: Pump Head Installation 13 Section 7: Pumping Water 16 Appendix 1: Exploded Pump System Diagram 17 Appendix 2: Maintenance 18 SECTION 1: INTRODUCTION PARTS SHIPPED TOOLS REQUIRED Thank you for purchasing a Simple Pump. Please carefully read through these instructions. Your time will be well spent. You will receive your Simple Pump partially assembled. The following section lists the different types of assemblies that you may receive, including whether assembled with other items. Compare the description to the packing list included with you shipment. PUMP HEAD ASSEMBLY (PHA) is comprised of these parts. Pump Head Stainless! Stainless Pump Rod. Only end shown, slightly pulled from packaging. Actual length about the same as Pump Head with Riser Tube (immediately above). Lever Link Arm Bracket Assembly. Preassembled brackets and hardware. Ready to attach to lever arm and head. 2

3 Clevis, Clevis Pin, 2 Shims. Pre-assembled onto the Lever Arm Assembly, a separate item. HANDLE (lever arm) 36 or 24. Clevis, clevis pin and shims are attached. WELL CAP One of these possible well caps: 2 Simple Pump cap with 1! split flange port for the Simple Pump only. 4, 4.5, 5, 6, 6.25 and 7 /8 Simple Pump caps. With 1-3/4" split flange port for the Simple Pump, 1" female NPT port for AC supply to a submersible and a 1-3/4" smooth wall port for submersible pipe. (Only one size shown.) 6 Trega clamshell cap. Packaged in its own box. Split flange. Packed outside Trega box. To be assembled onto Trega. 3

4 Drop pipe and sucker rod (can be in 9, 54 or 27 lengths). End shown. One rod guide per drop pipe kit. Often shipped in a separate container in one poly bag. Pump Cylinder Assembly: 100CA and 100CA-SS cylinder look the same -- top cylinder below. 125CA is bottom cylinder. Cylinder length is about 18 inches. Piston rod protrudes beyond cylinder by about 5 inches. ALSO USUALLY SHIPPED Safety Tool. Keeps the pump set from falling into the well during installation. Seal Kit. For first maintenance 3-10 years after installation. The 5-seals shown are for 3 gpm systems. 5 gpm system systems require 4 seals. Check valve with pressure gauge. For pumping into your home s pressure tank or uphill. These, above, are the core components. There are other components that may be part of your quote, that are not shown here. 4

5 TOOLS REQUIRED (1) Allen wrench (English, not metric) 3/16" Allen wrench for (4) 1/4-20 SS SHCS that attach the mechanism to the pump head. (2) channel locks: to grip 1! outer diameter PVC pipe (2) vise grips Roll of Teflon tape Bleach/water: 1 part bleach to 24 parts water. Wire cutters, strippers (if installing alongside an existing submersible pump) SECTION 2: DO IT YOURSELF, OR CALL A PROFESSIONAL? Before considering whether to perform this installation yourself, you need to first determine what type of well cap is on your existing well casing. NO PIPE THROUGH THE WELL CAP If your well cap does not have pipe from the submersible passing up through the middle, you have a pitless adaptor. You can quite possibly the installation yourself. You should be comfortable with both simple plumbing tasks and electrical wiring. With the wiring, you will disconnect your existing submersible well pump wiring under the cover and reconnect it through the new cover. You MUST be certain the power is disconnected while you are working. The line supplying power to submersibles almost always carry 240 volts. ELECTRICITY CAN KILL! DO NOT ATTEMPT TO PERFORM THIS WORK UNLESS YOU KNOW WHAT YOU ARE DOING. If you have the skills required to safely disconnect and connect power to the submersible (cut, splice and reconnect), the installation is really quite simple. STRONGLY RECOMMENDED #1: Whatever your water level, two people should install the Simple Pump. STRONGLY RECOMMENDED #2: If your water level is deeper than about 200 feet, we recommend professional installation. Each length of drop pipe is about 5 lbs. So at 200 feet water level, you eventually handle 130 lbs. At 350 water level, it would be 215 lbs. We can t of course know what weight you and your helper will be able to handle. SUBMERSIBLE OUTPUT PIPE THROUGH THE WELL CAP If your cover has pressure piping that passes through it and continues to your house system, it is best to employ a pump installer to at least install the Simple Pump well cap. Your pump installer has equipment to lift the cover with the attached string of pipes and pump, swap your current cap for the Simple Pump cap, and then place the pump set back in the casing with the new cap. DO NOT ATTEMPT TO REMOVE THIS TYPE OF COVER UNLESS YOU KNOW WHAT YOU ARE DOING! 5

6 SECTION 3: INSPECTING YOUR EXISTING SYSTEM This section applies if you have a pitless adaptor and you can remove your current well cap by hand. You will remove your existing cover and inspect your well for any obstacles that might obstruct the installation of your new hand pump. a) Make certain that your electric well power source has been shut off and locked off. b) Remove your existing cover. c) Untangle any wiring under the cover and pull the wires from the pump tight, with the excess out of the case. d) Confirm unobstructed clearance down the well. Shine a high-intensity light source down the well. Best is a mirror used to reflect the sun to shine down the casing. You can see the water reflecting as deep as 200 feet if the well is straight. If there is no pressurized water pipe through the cap, you will see a special fitting (called a "pitless adapter") that takes water coming up from the submersible through an exit on the side, underground. There must be enough clearance to allow piping to the hand pump pass beside this fitting. The 125CA 5 GPM cylinder requires 1-3/4" diameter clearance; the 3 GPM 100CA requires 1.6. On some installations, a number of "torque arrestors" are installed at intervals to keep the pipe and wiring at the center. These can prevent the hand pump piping from being installed. Yet, torque arrestors are only necessary very close to the electric pump and the Simple Pump is always installed 10 or more feet above it. If you find torque arresters preventing clearance, a well company can remove the unneeded ones. e) Check clearance for the cap inspect the rim of the well casing. No matter what cap or casing type you have, the cap fits onto the casing rim snugly, without much clearance by design so inspecting the rim is important to ensure proper fit. Side view check: The rim of the well casing should be smooth and level throughout. Top view check: The rim s thickness should be the same all the way around. Sometimes, if the casing was cut using a welding torch, there may be extra material on the outside that effectively thickens the rim. This needs to be removed. A sharp flat file will remove it. A hand grinder will also work very quickly. 2-INCH CASING? If your casing is 2, it requires a rigid support. Otherwise, the normal forces from lever-arm movement make a 2 casing deflect (as much as 2-3 for a metal casing or 6-7 for PVC. The best option is to not mount directly on the 2 casing at all. Use a 4-5 foot section of 6" metal casing as a sleeve with the original 2 casing housed inside. Or if that is not available, the 6 PVC casing we have supplied. Installation: If the casing is higher than 12 inches above ground level, cut the 2 casing down to 12 inches above ground level. Dig down so the 6 sleeve is embedded several feet into the earth, with its top two inches above the top of the 2 casing. Use the 6 well cap to help you correctly position the 6 casing off-center of the 2 sleeve. The Simple Pump port on the 6 cap is one of just three so all of the ports are located off-center. Backfill around the casing. Then securely cover the top of the 2 casing before using cement to fill the space between. Use just the fine slurry of Portland cement no aggregate. Now you can put the Simple Pump well cap on the 6 sleeve, with the drop pipes going down the 2 casing. 6

7 SECTION 4: EXISTING CAP REPLACEMENT WITH A SUBMERSIBLE PUMP This section addresses cap replacement for well with a currently installed electric submersible pump. a) When you untangled the pump wiring, you should have found connections. Typically these are wire nuts under electrical tape. They may be crimped connectors, in which case you will need to cut the wires close to the connectors. You will usually have three wire connection, which means three wires and a fourth that is ground. Note the colors and disconnect them. As an additional safety precaution, if you have a metal casing, take the bare wire ends coming from the house and touch them to the well casing one at a time as you disconnect them. If for some reason there was power, they would arc against the case and not you. The wires must reconnect in the same order. You may need to tie some twine onto the pump wires to keep them from falling down the well. The wires should however be taped to the piping a few feet down. b) Take the wiring from inside the casing, and pass through the 1" port in the new well cap. Now slide the well cap over the casing, level if necessary and tighten the four outer set screws. c) You will need to carefully evaluate your wiring to determine the best method to enclose the wiring. Sometimes flexible conduit is the easiest method. However you finish off the electrical conduit, make certain that each wire is reconnected to the same wire. d) Make certain that the wiring inside the casing does not obstruct the path for the hand pump piping as you look down through the split flange. The power cables and submersible s safety lifting cable should be taped to the pipe submersible pump s pipe, straight up from bottom to top. Neither should spiral around the pipe; they should be as flat against pipe as possible. If this is not the case, you should seek the help of a professional installer. e) Once your existing wiring is reconnected, you can energize your electric pump and make sure that it is working normally before you proceed. ***CRITICAL: YOU MUST HAVE YOUR NEW SIMPLE PUMP WELL CAP INSTALLED, as above, BEFORE PROCEEDING WITH THE NEXT STEP BELOW --- i.e. THE INSTALLATION OF YOUR DROP PIPES. *** SECTION 5: PUMP CYLINDER AND DROP PIPE KIT INSTALLATION INTRODUCTION In this section we will review the installation of the entire string of new drop pipe with the pump cylinder at the bottom. Being extremely cautious during this sequence is critical. It is possible to drop the drop pipes down the well. Follow these directions, carefully step by step! PREPARATION AND INSPECTION When you receive your pump system, the drop pipe kits arrive in a nine foot spiralwound fiber tube. The male threaded ends will be protected by a plastic cap. You need to remove that cap prior to installation. All the drop pipes should be the same, except one, the top drop pipe, the last to be installed. Its top will have the word weep handwritten on it. A 1/16 weep hole is drilled in it 48 from the top (or further down, if you requested a custom weep hole). 7

8 Each sucker rod is shipped inside of a drop pipe. The ends of the spiral-wound fiber tubes are wrapped with stretch wrap and tape. Very occasionally, from rough handling during shipping, a sucker rod has come out of the shipping tube, and then bent upon itself. That ruins the sucker rod, fracturing the fiberglass but the damage may not be totally obvious. Therefore, before installation, examine the length of each sucker rod visually and by running your hand slowly over it. The surface should be smooth with no imperfections. Wipe outside of all pipe, and rinse inside of pipe with the dilute bleach solution, taking care to remove any debris, dirt, PVC sawdust, etc. Place them where they will not be contaminated prior to installation. INSTALLATION Take the either Model 100 or Model 125 pump cylinder, and using the vice grips, connect the male threads on the piston rod and the female threads on a sucker rod. Use as much force as necessary. Stop when the two ends are shoulder to shoulder. Apply three wraps of Teflon tape on the male threads of the drop pipe (right). WARNINGS: Never use a liquid sealant/pipe dope. Never use more than three layers of Teflon tape. Bring the sucker rod that is already attached to the piston rod into the male end of the drop pipe. Thread the drop pipe into the pump cylinder (below). Be careful not to cross-thread. Tighten as far as possible by hand. Further tighten the PVC drop pipe into the body of the pump cylinder (by one-half revolution), while holding the pump cylinder with a channel lock. The 125CA is shown, (left) with white bushing. The 100CA has/ needs no white bushing to make this connection. The amount of torque desired is about a halfturn beyond hand tight. The drop pipe threads are tapered, so there is no need to use a heavy pipe wrench or any other tool that generates a great deal of torque. 8

9 INSERT CYLINDER AND DROP PIPE At this point you should have a 10.5-foot long assembly that includes the bottommost (9-foot) drop pipe, and the 18-inch-long pump cylinder. The 3 bolts on the top of the split flange should be slightly loose (horizontal arrows, photo on right), and the pinch bolt should be loose (vertical arrow, right). Have your safety tool handy and another person to help. Then, introduce the pump cylinder through the split flange that is mounted to the well cap. Note: As you introduce the cylinder past the split flange, you may find it difficult to move the leading edge past the O-ring in the split flange. You might have to use some Vaseline, or other lubricant, to get leading edge of the cylinder past that O-ring. The safety tool is then placed on the three bolt heads that mount the split flange to the well cap. Bring the bell end of the pipe down to rest in the safety tool. The safety tool will hold the entire set as it is assembled, keeping it from slipping into the well. 9

10 Place a rod guide over the protruding sucker rod (lower right). It will shimmy down into the female bell end, to the point where there is no threading. When the sucker rod is pushed down as far as it will go, there are about 5 inches of sucker rod protruding (left). This is the same amount of protrusion seen for the piston rod relative to the top edge of the pump cylinder. As we continue to add all the lengths of sucker rod and drop pipe, the goal is to maintain that distance between the top of the sucker rod and the top of the drop pipe. To get this result, try to have about ⅝ inches thread engagement between the female and male pipe ends. To achieve this, screw the two ends until hand tight. Then, using the two channel locks, screw onehalf rotation further no more. Attach the second sucker rod to the sucker rod just installed (left). Use your vice grips and/or channel locks to tighten shoulder to shoulder. There should be no visible gap that might make it possible to see threading (below). 10

11 Install the second drop pipe. As before, apply 3 wraps on the male threads (previously shown). Then, arch the sucker rod so that its end is inserted into the male end of the drop pipe (left). Screw the drop pipe ends together, ⅝ inches of engagement, or a half-rotation beyond hand-tight (lef). After connecting the drop pipe, lift up the drop pipe and remove the safety tool. Lower the drop pipe a few inches and replace the safety tool around the next drop pipe. Carefully lower the drop pipe until the next bell end is resting in the safety tool. Repeat the addition of drop pipe kits rod guide, then sucker rod, then drop pipe. Testing for water: During the installation of the last two to four drop pipe kits, the cylinder at the bottom of the pump set should be below the static water level. It is helpful for you to test for water by grasping the sucker rod, and moving it up and down (right). You will be able to feel when the piston at the bottom is moving in water. Certainly before proceeding with the installation of pump head, you should confirm that the pump cylinder is in water. Do not attempt to operate the pump unless you have determined that the cylinder is immersed in water. Pumping air can seriously damage the inside of the pump cylinder this damage is not covered by the five-year Simple Pump warranty. 11

12 (Installation is continued on next page, after this optional section.) OPTIONAL SECTION FOR 12 OR MORE 9-FOOT DROP PIPE KITS 1. T-HANDLE ASSIST TOOL Simple Pump recommends the T-Handle Assist Tool when the installation requires 12 or more 9-foot drop pipe kits. Also, this tool should be used if the person doing the installation has concerns about being able to hold onto the weight of a lesser number of drop pipe kits. HOW TO USE The downward-facing 1" male threads on the T-Handle are threaded into the upward-facing 1" female bell-end on the drop pipe kits. The T-Handle provides a safe grip area for the lowering of the drop pipe string when the female bell end is at about eye level down to the point where the bell end is cradled in the safety tool (left). Once the string of drop pipe is safely resting in the SIM073 Safety Tool, the T-Handle can be unthreaded and reattached to the next-tobe-installed 9 foot drop pipe kit. 2. ROD EXTENDERS In a fully-installed Simple Pump, moving the lever arm from the very top of its stroke range to the bottom of the stroke range moves the piston in the pump cylinder (at the bottom) 10.5 inches. The piston can travel 2.5 inches up and down from exact center position in the cylinder without the piston topping out or bottoming out. When you attach the final / top drop pipe, check to make sure that you have 4 to 5 of sucker rod protruding from the top of the top drop pipe bell end with SS close nipple in place. If it is less that four inches, you can adjust the length of the sucker rod by adding one or more rod extenders so you have a 4 to 5 extension." These will have been included in your quote, if you have 12 or more 9 drop pipes. If rod extenders are needed, use Loctite or other thread bonder on both the male and female ends. (End of optional material.)

13 SECTION 6: PUMP HEAD INSTALLATION Install the 1"x2" stainless steel threaded connector Bring the riser tube (and attached pump Apply three wraps of teflon tape to the thread of the 1" by 2" stainless nipple (not shown). (nipple) on the top of the last drop pipe (below). Hand tighten. head) over the pump rod and lower it down. Do so slowly there is a 8-inch-long rod gland at the top of the riser Hand tighten the riser tube onto the nipple. Then using two channel locks, tightening a halfturn past hand tight (not shown). The nipple will essentially disappear so the two female ends will end up being nearly butted. Bring the! inch stainless pump rod, and thread it onto the upward facing male end of the top sucker rod. Grip the bottom sucker rod as shown (below) There are flats at the top of the pump rod that you can use to get a grip on the rod. tube, so make sure, as you lower it, to align the riser tube so the pump rod is in the very middle, so it can be moved through the more narrow opening of the rod gland. 13 At this point, the pump set is heaviest a second pair of hands can help here most. Remove the safety tool, lifting up a little on the bell end (left). Lower the pump set until the riser tube is at the the desired position. Tighten the pinch bolt on the split flange. Tighten the three mounting bolts on the split flange.

14 ATTACH THE LEVER ARM TO ITS BRACKET The 24" or 36" lever arms are supplied partially preassembled. We assemble the clevis, the two brass shims, and the clevis pin to the lever arm ordered. Separately, the mating mechanism the lever bracket, the lever link arm and the clevis pin plus shims are combined into the Lever Link Arm Bracket Assembly. Put these together before attempting to attach them to the pump head -- put them on a flat surface. Introduce the first shim between then two mating parts (right). Use a small screwdriver, or a small Allen wrench, to reach inside, centering the shim (right) Push the pin through partway (below). Then, flip the partially-connect assemblies over, gently push back the pin out just a bit (not shown). This will give you the clearance to install the second brass shim. As with the first side, use the small screwdriver, Allen wrench or something similar to center the shim. Then, press down on the assembly (not the pin) so the table you are on pushes the head of pin all the way through, upward, toward you (not shown). 14

15 Bring the clevis into position above the! inch stainless rod. Thread it into position (right). The threads are left-hand threads -- you tighten them by going counterclockwise, not clockwise. The lever bracket is brought into position (below). You may have to lift up on the pump rod in order to get the holes to align correctly (below). There are four long cap screws that need to be secured using an Allen wrench. PUMPING TO YOUR PRESSURE TANK A! stainless steel outlet nipple and a brass, lead-free, garden hose adapter are included with every pump head assembly. If you intend to pressurize your house pressure tank from the hand pump, or pump uphill, install a check valve. The Simple Pump check valve, the stainless nipple and garden hose adapter are all shown, right. Make sure to use a check valve, or a relief valve, to prevent generating more than 50 psi into any plumbing. The Simple Pump can generate over 100 psi. 15

16 SECTION 7: PUMPING WATER It will require about one stroke for each foot of water depth to get the water up to the pump head. 100 feet will require about about 100 strokes. There is a very small (1/16 ) bleeder ( weep ) hole about 4 feet below your pump head, in the top drop pipe. This takes about 15 minutes to drain and protects the pump against freezing. Each time you go out to pump after a period of time, it will require about six to eight strokes to get the water back to the pump head. The check valves in the pump cylinder allow a very small amount of leakage over time. Over several days or weeks, you may need to pump a few extra strokes to get the water back to the top. PUMPING INTO PRESSURE DURING SUSTAINED FREEZES The weep hole is not sufficient to prevent damage to the pump when pumping into pressurized plumbing. When pumping stops, the check valve holds water in the line. The hose to the pressurized system must be disconnected AT THE PUMP HEAD to allow air into the system to allow the water to weep down. You will also, of course, need to drain the hose, itself. NORMAL POSITION OF THE PUMP HANDLE The normal at-rest position of the lever arm is vertical (right). The lever arm's vertical resting position keeps the rod inside the rod gland. This protects the rod from sources of contamination. Do NOT tie the handle in the down position. IF AWAY FROM THE PUMP: REMOVING HANDLE FOR SECURITY In some circumstances, you may wish to remove the handle and take it with you, reinstalling for each use. This is a simple procedure that just takes a few minutes. (Please keep in mind that the threads on the 3/4" stainless rod and clevis are lefthand.) Do not remove any of the three clevis pins. Leave the complete lever arm linkage in one connected grouping. Remove the (4)-1/4-20 x 1/2" hex head cap screws where the lever bracket is attached to the flat, machined face on the pump head. Then use the lever arm (with lever link arm and lever bracket still connected) as a wrench handle to unscrew the clevis from the 3/4" stainless rod in the pump head. (You may need to use a crescent wrench to hold the 3/4" stainless rod from rotating while disconnecting the clevis.) 16

17 APPENDIX 1: EXPLODED PUMP SYSTEM DIAGRAM (SIM032) (SIM020A) (24LA or 36LA) CLEVIS PIN (90156A383) (SIM021) TOP DROP PIPE (109DPTBE-48) (SIM042) SUCKER ROD (D2-108) STANDARD DROP PIPE (109DPE) SPLIT FLANGE (SIM054A) WELL CAP (C2, C4, C5, C6, C7 or C8) (below DPADJ KIT) (100CA or 125CA) (100CA or 125CA) (100CA or 125CA) (100CA or 125CA) 17

18 APPENDIX 2: MAINTENANCE 1. OCCASIONAL PUMPING If your water has a high suspended solids content or high minerals content, deposits could accumulate on parts. Work the pump monthly for a few minutes to keep deposits from forming. 2. SEAL KIT AND ROD GLAND REPLACEMENT INSTRUCTIONS SIGNS THAT SEALS NEED REPLACING The length of time between seal replacement can vary greatly with amount of use and water quality. Most clients have done maintenance at somewhere between three and ten years: For piston seals: when output drops appreciably. For pump heads seals: when water leaks between the pump rod and the rod gland in the pump head. SEAL KIT DETAILS Model 100: The seal kit for a model 100CA pump cylinder assembly and pump head is comprised of five (5), 90 u-cup seals. Two (2) u-cup seals are provided for the rod gland in the pump head, and three (3) u- cup seals are provided for the piston in the pump cylinder. Model 125: The seal kit for a model 125CA pump cylinder assembly and pump head is comprised of four (4), 90 u-cup seals. Two (2) u-cup seals for the rod gland in the pump head, and two (2) u-cup seals are provided are provided for the piston in the pump cylinder. Note that rod gland gland replacement is also explained, but the need for it is rare. CHANGING THE SEALS AND ROD GLAND FIRST - REMOVE THE LEVER ARM ASSEMBLY All seal replacements start with removing the lever arm mechanism: Using the 3/16" Allen wrench, remove each of the four fasteners that hold the lever arm mechanism to the pump head (right). Unscrew the clevis from the pump rod. Move the lever arm clockwise while keeping the pump rod from rotating using your vice grip or channel lock (right). The direction you unscrew is the opposite of normal -- turn clockwise to remove, rather than the normal counterclockwise. This will remove the lever link arm, bracket, and lever arm (they should still be connected), from the 3/4" stainless rod. 18

19 CHANGING THE PUMP HEAD SEALS AND ROD GLAND Remove the pump head by unscrewing it (right). Rotate it in a counterclockwise motion. A good number of rotations are required before it detaches from the riser tube.you may need to first loosen it with a channel lock. PUMP HEAD SEALS The 2 u-cup seals in the pump head are located at the top end of the rod gland, in two machined grooves (top arrow, left). Once the pump head has been removed, the u-cup seals can be easily accessed for removal / installation. Rod gland U-cup seals MUST be installed with open end of U facing DOWN (right). ROD GLAND REPLACEMENT The rod gland runs the length of the assembly at length (middle arrow, above). Remove the spider (lowest arrow, above) by unscrewing (counterclockwise). Remove the rod gland from the stainless pump head using the channel locks (counter-clockwise to loosen)...leave the o-ring in place beneath rod gland in pump head. Repeat all steps in reverse to install the new rod gland. PISTON SEALS In order to replace u-cup seals on the piston, the pump system must be pulled from the well as the piston is at the bottom. Piston U-cup seals MUST be installed with open end of U facing UPWARD. For the Model 100, this will be three (3) seals. For the Model 125, this will be two (2) seals. (right) 19

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP LAST UPDATED: June 25, 2018 We recommend you view the installation video for an overview, before using these instructions. If you are a homeowner, we recommend

More information

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP LAST UPDATED: January 10, 2019 It is highly recommended you view the entire installation video for an overview before using these instructions. http://www.simplepump.com/support/installation-videos/

More information

Installation Instructions for Model 100L. and for Model 100T Hand Pump

Installation Instructions for Model 100L. and for Model 100T Hand Pump Installation Instructions for Model 100L and for Model 100T Hand Pump (Prerequisite for 12v gear motor option - also see separate instructions) Contents Introduction Assembly Parts List Section 1: Do It

More information

INSTALLATION PROCEDURE FOR MODEL ADA100 ROTARY HAND PUMP

INSTALLATION PROCEDURE FOR MODEL ADA100 ROTARY HAND PUMP INSTALLATION PROCEDURE FOR MODEL ADA100 ROTARY HAND PUMP (The following instructions are very detailed, and should tell you everything you need to know. If you have questions, please phone 775-265-1220.)

More information

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,

More information

Manifold Isolation Valves

Manifold Isolation Valves 300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X

VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X ASSEMBLY MANUAL Keep With Operator s Manual VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X TRACTOR AND VALVE KIT GENERAL

More information

VALVE AND PLUMBING KIT NEW HOLLAND 7310 LOADER NEW HOLLAND TRACTORS

VALVE AND PLUMBING KIT NEW HOLLAND 7310 LOADER NEW HOLLAND TRACTORS ASSEMBLY MANUAL Keep With Operator s Manual VALVE AND PLUMBING KIT NEW HOLLAND 73 LOADER NEW HOLLAND TRACTORS MODEL 2WD FWA LESS CAB WITH CAB TT55 X X X TT75 X X X Valve and plumbing kit can be installed

More information

HEAVY DUTY TROLLEY JACK. Operation Manual

HEAVY DUTY TROLLEY JACK. Operation Manual HEAVY DUTY TROLLEY JACK 4T Operation Manual Make sure to read and fully understand the instruction manual before using this product and keep the manual properly 1 General Description Product Description

More information

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components Page 1 Introduction The M-8200 Precision Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options with

More information

A B C D E F. Tools Required (supplied by others)

A B C D E F. Tools Required (supplied by others) Page 1 of 17 Parts List Below Deck Automatic Retractable Security Cover Kit (1) Tube End Bearing Plate (A) (1) Rope Reel and Cover Drum Motor Assembly (B) (1) Cover Drum (1) Pulley Support Channel (2)

More information

VALVE AND PLUMBING KIT 2408TL LOADER AGCO & MASSEY FERGUSON TRACTORS

VALVE AND PLUMBING KIT 2408TL LOADER AGCO & MASSEY FERGUSON TRACTORS ASSEMBLY MANUAL Keep With Operator s Manual VALVE AND PLUMBING KIT 2408TL LOADER AGCO & MASSEY FERGUSON TRACTORS AGCO MASSEY FERGUSON CAB ROPS ST34A 1533 X ST41A 1540 N/A X TRACTOR AND VALVE KIT GENERAL

More information

THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS

THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS PAGE 1 OF 13 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS CPI / Perma Plugs are part of the Pop-A-Plug Tube Plugging System. Unlike other tube plug designs, and under the proper conditions, CPI / Perma

More information

VALVE AND PLUMBING KIT 2409 LOADER CUB CADET & KIOTI TRACTORS

VALVE AND PLUMBING KIT 2409 LOADER CUB CADET & KIOTI TRACTORS ASSEMBLY MANUAL Keep With Operator s Manual VALVE AND PLUMBING KIT 2409 LOADER CUB CADET & KIOTI TRACTORS TRACTOR MODELS CUB CADET 8404, 8454 KIOTI DK45, DK50 ROPS X X TRACTOR AND VALVE KIT GENERAL INFORMATION

More information

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Blvd. Dagenais West LAVAL (QUEBEC) CANADA H7L 5X9 MODELS 503132S 503332 503232S 503732 TEL : 514.337.4415 FAX : 514.337.4029 info@burcam.com Your pump has

More information

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS Model T033 CONVERTIBLE JET PUMP /HP 900 GPH Suction lift Head of 5 (7.5m) in shallow well mode Professional Series YEAR WARRANTY Suction: /4 Discharge: NPT Maximum pressure: 85 PSI US GPH LPH 5 900 3400

More information

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS WITH HYDRAULIC CONTROL PACKAGE PART NUMBER: SE-023 REVISION:

More information

Installation Instructions Table of Contents

Installation Instructions Table of Contents Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft

More information

E-LIFT II+ SYSTEM WITH SPRING LEVER FOR A-SERIES AND FULL FRAME LOOMS

E-LIFT II+ SYSTEM WITH SPRING LEVER FOR A-SERIES AND FULL FRAME LOOMS Congratulations on your purchase of the E-Lift II+ system. This system replaces the action of treadling, eliminating leg strain and fatigue. When you activate the Foot Switch, the motor turns, and selected

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : GTL 1110 1900-0510 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C.,

More information

ASSEMBLY MANUAL. Keep With Operator s Manual

ASSEMBLY MANUAL. Keep With Operator s Manual ASSEMBLY MANUAL Keep With Operator s Manual 2-6347 VALVE AND PLUMBING KIT INSTRUCTIONS SMC 64Q LOADER KUBOTA TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB B2150DT & B2150HSD X X B8200DT & B8200HSD X X B9200DT

More information

ASSEMBLY MANUAL SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS

ASSEMBLY MANUAL SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS ASSEMBLY MANUAL Keep With Loader Operator's Manual SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB L5450 X X Valve and plumbing kit can be installed

More information

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve To complement our extensive line of cable pressurization products, System Studies also sells a variety of air pipe and pressure tube fittings. This section of the catalog describes these commonly used

More information

MM Rear Coil-Over Kit - Bilstein Shocks (MMCO-3)

MM Rear Coil-Over Kit - Bilstein Shocks (MMCO-3) 3430 Sacramento Dr., Unit D San Luis Obispo, CA 93401 Telephone: 805/544-8748 Fax: 805/544-8645 www.maximummotorsports.com MM Rear Coil-Over Kit - Bilstein Shocks (MMCO-3) Read all instructions before

More information

DUAL REMOTE OIL FILTER MODIFICATION 4 TH GENERATION FIREBIRDS

DUAL REMOTE OIL FILTER MODIFICATION 4 TH GENERATION FIREBIRDS Written by Dave Dorey (lonetechie) Copyright FirebirdNation.com The following article details how I installed a dual remote oil filter system on my 2001 Formula Firebird. If you decide to tackle this project,

More information

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

A B C D E F. b.tools Required (supplied by others) 3/16 Drill Bit 3/8 Wrench Phillips Head Screwdriver Page 1 of 13 5E.1 Parts List a. Below Deck Automatic Retractable Security Cover Kit (1) Tube End Bearing Plate (A) (1) Rope Reel with Motor Attached (B) (1) Rope Reel Cover (C) (1) Cover Drum (1) Cover

More information

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems Instruction Sheet 408-8040 30 NOV 17 Rev H Ram Assembly Ram Post Locking Screw Stock Drag Drag Release

More information

1.1 Quad Valve and Tri-Valve. Contents WATER DUMP BODY O-RING EXHAUST VALVE QUAD VALVE TIE WRAP EXHAUST MAIN BODY O-RING

1.1 Quad Valve and Tri-Valve. Contents WATER DUMP BODY O-RING EXHAUST VALVE QUAD VALVE TIE WRAP EXHAUST MAIN BODY O-RING Quad Valve and Tri-Valve Exhaust Assembly on Fiberglass Helmets Quad Valve and Tri-Valve Exhaust Contents QUAD-1 QUAD-2 QUAD-2 QUAD-2 QUAD-6 QUAD-7 1.1 Quad Valve and Tri- Valve Exhaust Assembly on Fiberglass

More information

Final Assembly Instructions: Runaround Cruiser

Final Assembly Instructions: Runaround Cruiser Final Assembly Instructions: Runaround Cruiser Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our expert

More information

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

More information

Instructions for Assembling Driving Wheels, Axles and Crankpins

Instructions for Assembling Driving Wheels, Axles and Crankpins Instructions for Assembling Driving Wheels, Axles and Crankpins (Version 1; October 2008) Introduction These instructions explain how to assemble Exactoscale 4mm scale driving wheels, axles and crankpins

More information

VALVE AND PLUMBING KIT 4211 LOADER CASE IH JX55, JX65, JX75,JX85, AND JX95 TRACKTORS NON-CAB

VALVE AND PLUMBING KIT 4211 LOADER CASE IH JX55, JX65, JX75,JX85, AND JX95 TRACKTORS NON-CAB ASSEMBLY MANUAL 2-7293 Keep With Operator s Manual VALVE AND PLUMBING KIT 42 LOADER CASE IH JX55, JX65, JX75,JX5, AND JX95 TRACKTORS NON-CAB Valve and plumbing kit can be installed using tools ordinarily

More information

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport Sachs shock manual (2013 2015) 2 & 4 Stroke RR Enduro (2014-2015) RS Dual Sport 1 Introduction The procedures in this manual must take place in a clean environment using professional tools and some specific,

More information

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC Installation, Operation, and Maintenance Manual Welker Automatic Insertion Corrosion Coupon Device Model The information in this manual has been carefully checked for accuracy and is intended to be used

More information

Model 800 Disassembly Instructions and Troubleshooting

Model 800 Disassembly Instructions and Troubleshooting Model 800 Disassembly Instructions and Troubleshooting 1 Index Page Solenoid Disassembly Instructions 2,3 Removing Adaptor from Anti-siphon Body 4,5 Adaptor Disassembly Instructions 6-9 Troubleshooting

More information

Piston Replacement Kit

Piston Replacement Kit Varian, Inc. www.varianinc.com Piston Replacement Kit Each piston in the SD-1 can be replaced using a replacement kit listed below. Both pistons should be replaced at the same time unless one of the pistons

More information

Final Assembly Instructions: Bikes with Threadless Headsets

Final Assembly Instructions: Bikes with Threadless Headsets Final Assembly Instructions: Bikes with Threadless Headsets Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping,

More information

An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features

An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features Constant Level Lubricators Table of Contents Overview Typical Applications and Industries..........................

More information

INSTALLATION INSTRUCTIONS REPAIR SEAL KIT PowerSurvivor 40E

INSTALLATION INSTRUCTIONS REPAIR SEAL KIT PowerSurvivor 40E INSTALLATION INSTRUCTIONS REPAIR SEAL KIT PowerSurvivor 40E PURPOSE OF THE KIT The Repair Seal Kit should be installed after 1000 hours of operation. It should be installed regardless of whether or not

More information

PMV P36C AND P41C POSITIONERS ACTUATORS

PMV P36C AND P41C POSITIONERS ACTUATORS PMV P36C AND P41C POSITIONERS USED WITH DeZURIK PNEUMATIC ACTUATORS Instruction D10327 August 2012 Instructions These instructions provide information about Models P36C and P41C PMV Positioners. They are

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Automatic Insertion Heated Regulator High Voltage Model IHRA-4SS-220/230 100 or more inch insertion length The information in this manual has been

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : GRL 1110 1900-0540 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

M52tu-M54 VANOS Assembly & Timing Using G.A.S. Professional Cam Tool Kit

M52tu-M54 VANOS Assembly & Timing Using G.A.S. Professional Cam Tool Kit Home BMW Solutions Porsche Solutions DIY Tech Engine Services Dyno Services Machining About Contact Store Tool Rental M52tu-M54 VANOS Assembly & Timing Using G.A.S. Professional Cam Tool Kit This procedure

More information

Backpack Sprayer. Use and Care Manual

Backpack Sprayer. Use and Care Manual Backpack Sprayer Use and Care Manual BACKPACK SPRAYER CAUTION: Read and follow all instructions Do Not Return This Backpack To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead

More information

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2 SD-03-832 Bendix E-10PR Retarder Control Brake Valve MOUNTING PLATE SUPPLY 4 PORTS ELECTRICAL AUXILIARY DESCRIPTION TREADLE RETARDER CONTROL SECTION EXHAUST DELIVERY 4 PORTS FIGURE 1 - E-10PR RETARDER

More information

Maverick American 3085 Bluff Street Boulder, CO Tel: Fax: ML7.0 SHOCK SERVICE MANUAL

Maverick American 3085 Bluff Street Boulder, CO Tel: Fax: ML7.0 SHOCK SERVICE MANUAL Maverick American 3085 Bluff Street Boulder, CO 80301 Tel: 303-415-0370 Fax: 303-415-0676 www.maverickamerican.com ML7.0 SHOCK SERVICE MANUAL 1. OVERVIEW 1.1. The Maverick ML7.0 rear shock is an oil damped

More information

Air Conditioner for M915 A0/A1 Truck

Air Conditioner for M915 A0/A1 Truck RD-2-4530-0 Air Conditioner for M915 A0/A1 Truck INSTALLATION INSTRUCTIONS Install refrigerant compressor per instructions provided with compressor mount kit. CAUTION: Edges of sheet metal can be sharp!

More information

Instruction Manual Includes:

Instruction Manual Includes: Instruction Manual Includes: Page 1: HydraHorse Installation for Basic 2- Horse System Part I: Tank, pump, and electrical supply Page 6: Page 9: Part II: Page Bowls, Brackets, Pipes and Fittings Installing

More information

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems Instruction Sheet 408-8039 02 JUN 16 Rev G Ram Post Wire Disc Insulation Disc Insulation Crimper Stripper

More information

BEFORE BEGINNING INSTALLATION

BEFORE BEGINNING INSTALLATION COMPLETE CHASSIS FUEL LINE KITS For 1996-2000 Honda Civic Equipped with B-Series Engine INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. Most installations

More information

EST GROUP DC /96 REV 8 03/03 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS

EST GROUP DC /96 REV 8 03/03 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA CPI / Perma Plugs are part of the Pop-A-Plug Tube Plugging System. Unlike other tube plug designs, and under the proper conditions, CPI / Perma Plugs

More information

Installation instructions for Camaro/Firebird and Nova* Windshield Wiper Systems

Installation instructions for Camaro/Firebird and Nova* Windshield Wiper Systems Installation instructions for 1967-69 Camaro/Firebird and 1968-74 Nova* Windshield Wiper Systems The Raingear 1967-69 Camaro/Firebird and 1964-74 Nova wiper system is designed for ease of installation

More information

Baumann Series Flexsleev Control Valve Instructions

Baumann Series Flexsleev Control Valve Instructions Instruction Baumann 86000 Series Instructions Baumann 86000 Series Flexsleev Control Valve Instructions Contents Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Installation...3 Air Piping...3

More information

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP Model T03121 SHALLOW WELL JET PUMP Professional Series 2 YEAR WARRANTY 1/2HP 916 GPH Head of 25 (7,5 m) US GPH LPH Suction: 1 1/4 NPT Discharge: 1 NPT Maximum Pressure: 65 PSI Stainless steel shaft and

More information

Rollstar Shade Installation Instructions

Rollstar Shade Installation Instructions Rollstar Shade Installation Instructions All Lifting Systems Inside or Outside Mount Thank you for purchasing your new Rollstar shade. It has been custom-made from the highest quality materials to the

More information

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material 5.2018.12.i 6200 Series Specifications The Flomore 6200 Series Pump line consists of a series of basic pump options all developed from a modular power unit. All units are pneumatically driven positive

More information

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.

More information

Fig Variable Speed Valve Parts

Fig Variable Speed Valve Parts 5 DISASSEMBLY OF VARIABLE SPEED CONTROL VALVE (Seal Replacement with Control Valve in the Bobcat). Remove seat and seat plate (Fig. ).. Remove variable speed control lever linkage rod. 3. Remove temperature

More information

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS WARNING! THESE INSTRUCTIONS MUST BE READ AND FULLY UNDERSTOOD BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN POOR PERFORMANCE,

More information

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction...

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction... 1 CONTENTS Product Features and Specifications... 3 Installation Requirement... 5 Installation... 6 Exploded View... 20 Test... 22 Operation Instruction... 25 Maintenance... 26 Trouble Shooting... 27 Parts

More information

INSTALLATION MANUAL 2000WCY

INSTALLATION MANUAL 2000WCY INSTALLATION MANUAL 2000WCY Pressure Cleaning System spraymastertech.com Spray Master Technologies is a quality product line of Assembled Products Corp. 115 E. Linden Rogers, Arkansas 72756 USA (479) 636-5776

More information

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # 20100742 TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON

More information

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS Page 1 of 5 Step 1: ASSEMBLE THE MAIN MANIFOLD AND MANIFOLD EXTENSION KIT First and very important step is to properly connect the main manifold and the manifold extension kit together by using the two

More information

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website INSTALL MANUAL FOR ON LINE ORDERING- E Commerce Visit Our Website WWW.PRESSUREGUARD.COM Contact Information Technical Support: Chris@pressureguard.com Sales Support: Sales@pressureguard.com By Phone: 615-227-6024

More information

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been

More information

'99-03 CHEVROLET/GMC IFS 4WD 6" SUSPENSION SYSTEM P/N INSTALLATION INSTRUCTIONS

'99-03 CHEVROLET/GMC IFS 4WD 6 SUSPENSION SYSTEM P/N INSTALLATION INSTRUCTIONS 1/16/04 '99-03 CHEVROLET/GMC IFS 4WD 6" SUSPENSION SYSTEM P/N. 10-41099 INSTALLATION INSTRUCTIONS NOTE: Each Lift Kit and options to Lift Kits are packaged separately. Therefore, installation procedures

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles Case IH Vehicles Case 2577 Combines Case 2588 Combines Accuguide Ready PN: 602-0233-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions

More information

INSTALLATION INSTRUCTIONS South Highway 11 Westminster, SC Toll Free (888) (864) FAX (864)

INSTALLATION INSTRUCTIONS South Highway 11 Westminster, SC Toll Free (888) (864) FAX (864) These instructions apply to the servicing of the Lift Technologies MaxiMizer Integral Sideshifters Cylinder Head. WARNING! Unless the steps in the following Installation Instructions are properly followed

More information

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD Product Instructions CONTENTS 1. Scope 3 2. Product Overview 3 3. Technical Data 5 4. Mounting the Manifold 7 5. Installing RAUPEX Pipes 8 6. Flushing and Filling Radiant

More information

MM Rear Coil-Over Kit - Koni Single and Double Adjustable Shocks (MMCO-5)

MM Rear Coil-Over Kit - Koni Single and Double Adjustable Shocks (MMCO-5) 3430 Sacramento Dr., Unit D San Luis Obispo, CA 93401 Telephone: 805/544-8748 Fax: 805/544-8645 www.maximummotorsports.com MM Rear Coil-Over Kit - Koni Single and Double Adjustable Shocks (MMCO-5) Read

More information

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives

More information

How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1

How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1 Seth Johnson How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1 History: A man named John Whitehurst first created the Hydraulic Ram Pump in 1772. That means that this ingenious

More information

TOPAZ Service Guide. Full Service

TOPAZ Service Guide. Full Service TOPAZ Service Guide Full Service SERVICE OVERVIEW This manual will guide you step by step performing an air service to your Topaz. Please follow each instruction carefully to achieve the best and safest

More information

Maintenance Information

Maintenance Information Form 16575334 Edition 1 April 2005 Electric Screwdrivers EL, EP and ET 34V DC Series Maintenance Information Save These Instructions WARNING Maintenance procedures have the potential for severe shock hazard

More information

Maintenance Instructions

Maintenance Instructions General Note These instructions contain information common to more than one model of Bevel Gear Drive. To simplify reading, similar models have been grouped as follows: GROUP 1 Models 11, 0, 1,, (illustrated),,

More information

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator

More information

Operation and Maintenance Manual

Operation and Maintenance Manual BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may

More information

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10 DP5 Pump 5:1, Air-operated, Heavy Duty, Oil General The DP5 Pump is a compressed air-operated reciprocating piston medium pressure pump. These pumps are suitable for distribution of all types of light

More information

Installation Instructions

Installation Instructions Installation Instructions Product: SwitchBlade Swaybar System Part Number: PN 9100 Application: Jeep Wrangler TJ, 1997-06 (front) Welcome CONGRATULATIONS on purchasing a SwitchBlade Swaybar System from

More information

Thank you for purchasing the Craven Speed FlexPod Complete Gauge Pod Kit For R56, R58, R59, R60 with Refresh Engines (2011+)

Thank you for purchasing the Craven Speed FlexPod Complete Gauge Pod Kit For R56, R58, R59, R60 with Refresh Engines (2011+) Thank you for purchasing the Craven Speed FlexPod Complete Gauge Pod Kit For R56, R58, R59, R60 with Refresh Engines (2011+) Before You Start Please read instructions completely before installing. These

More information

OCTOPUS SERVICE PROCEDURE - SP007 REV NEW 15-FEB-2008

OCTOPUS SERVICE PROCEDURE - SP007 REV NEW 15-FEB-2008 OCTOPUS SERVICE PROCEDURE - SP007 REV NEW 15-FEB-2008 APPLICABLE MODELS a. Both styles of Octopus Hydraulic 38mm Bore Linear Drive. (LAM = Linear Actuator Mounted & LAR = Linear Actuator Remote) REQUIRED

More information

Technical Manual MSI Hydraulic Adjustable Choke

Technical Manual MSI Hydraulic Adjustable Choke Technical Manual MSI Hydraulic Adjustable Choke MSI A Division of Dixie Iron Works, Ltd. 300 W. Main St. Alice, TX 78332 www.diwmsi.com (800) 242-0059 Revision A TABLE OF CONTENTS SECTION 1 WARNINGS...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 28 INSTALLATION INSTRUCTIONS SECTION - AIR SPRING SECTION 2 - AIR ACCESSORY 2-5 ! IMPORTANT PLEASE DON T HURT YOURSELF, YOUR KIT OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. This

More information

Check List for Optimal Filter Performance

Check List for Optimal Filter Performance Check List for Optimal Filter Performance There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and a 1.5" or 2 valve should have a 3 waste line. Do not use rubber hosing

More information

Operation and Maintenance Instructions

Operation and Maintenance Instructions Operation and Maintenance Instructions One Research Drive Stratford, CT 06615 (203) 375-0063 www.sonicmixing.com 1 Installation and Start-up Do not perform following adjustments without disconnecting power

More information

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS WARNING! THESE INSTRUCTIONS MUST BE READ AND FULLY UNDERSTOOD BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN POOR PERFORMANCE,

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

The portable, hand-held rebar bending and cutting system. OPERATOR S MANUAL Made in U.S.A.

The portable, hand-held rebar bending and cutting system. OPERATOR S MANUAL Made in U.S.A. The portable, hand-held rebar bending and cutting system. OPERATOR S MANUAL -800-665-7549 Made in U.S.A. Thank you for purchasing an EZE BEND SYSTEM. The OPERATOR S MANUAL provides information for all

More information

Service Kit

Service Kit Service Kit 753-05607 Date: Subject: Models Affected: April 17, 2009 (Revised 6/08/2009) Hydraulic Cylinder Seal Replacement XINGHUI 4.5 Cylinder 718-0769A Read through and understand these instructions

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles Case IH Combines 7010 7120 8010 8120 AFX 8010 9120 PN: 602-0283-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual carefully

More information

Maintenance Information

Maintenance Information 80234313 Edition 1 June 2006 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing

More information

GM C10 Street Grip

GM C10 Street Grip Part # 11365010/11365110-1973-1987 GM C10 StreetGrip Front Components 11369590 Delrin Control Arm Bushings 11369300 Drop Spindles 11362350/11362351 Front CoilSpring Kit 11369515 Front HQ Series Shocks

More information

Transmate. Installation & Operating Manual. Thank you for your purchase of the InsertaValve.

Transmate. Installation & Operating Manual. Thank you for your purchase of the InsertaValve. Installation & Operating Manual Thank you for your purchase of the InsertaValve. Please read and understand this operation manual. Our goal is to serve you, our customer. If you have any questions, complaints

More information

Materials List: Tools List:

Materials List: Tools List: Materials List: Anchor assembly Automated power supply Automated power supply hardware packet Automation bracket assembly Automation bracket assembly hardware packet Automation winch assembly Cable Cable

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

HKV 1 1/4 in. Brass Manifold Product instructions.   Construction Automotive Industry HKV 1 1/4 in. Brass Manifold Product instructions www.rehau.com Construction Automotive Industry SCOPE This guide provides instruction regarding HKV 1 1/4 in. manifold installation and operation. Manifolds

More information

House Hydrant Installation Instructions

House Hydrant Installation Instructions House Hydrant Installation Instructions Please read all instructions and warnings before installing. WARNING Failure to turn off water supply prior to installation can result in personal injury or damage

More information

Sachs 48mm Closed Cartridge fork Service Manual

Sachs 48mm Closed Cartridge fork Service Manual Sachs 48mm Closed Cartridge fork Service Manual 1 Fork seal driver 2 Special soft jaws 3 Fork cap wrench 4 Rebound rod holding tool 5 Compression assembly holding tool 6 Retaining clip tool Special Tools

More information