Installation Instructions for Model 100L. and for Model 100T Hand Pump

Size: px
Start display at page:

Download "Installation Instructions for Model 100L. and for Model 100T Hand Pump"

Transcription

1 Installation Instructions for Model 100L and for Model 100T Hand Pump (Prerequisite for 12v gear motor option - also see separate instructions) Contents Introduction Assembly Parts List Section 1: Do It Your Self or Call a Pump Professional? Section 2: Inspecting Your Existing System. Section 3: Replacing The Existing Well Cover. Section 4: Pump Cylinder, Drop Pipe Installation. Section 5: Pump Head Installation. Section 6: Pumping Water, Finishing Touches. Introduction Thank you for purchasing your pump assembly. We are extremely proud of these high quality components. We have installed the pumps in a variety of well types and sizes and our instructions are a result of experiences in those installations. Please carefully read through these instructions. Your time will be well spent. At any time, if you think you are overwhelmed, please get the help of a qualified, professional pump installer.

2 We will be referring to parts by their part number and name. Use the Assembly Parts List to identify parts as you read through these instructions. View the Assembly Parts List. Section 1: Do It Yourself or Call a Pump Professional? Before considering whether to perform this installation yourself, you need to first determine what type of cover is on your existing well case. Replacing your existing well cover with the cover provided with your new pump is necessary to support the hand pump head. Covers are made in a wide variety of shapes and form. We break them down into two categories for determining who will perform the installation: PRESSURE PIPE THROUGH THE COVER If your cover has pressure piping that passes through it and continues to your house system, a pump installer can easily do the task of replacing the cover. This type of cover generally supports the entire string of pipe extending down to the electric pump. This string of pipe can weigh hundreds of pounds. DO NOT ATTEMPT TO REMOVE THIS TYPE OF COVER UNLESS YOU KNOW WHAT YOU ARE DOING! Your pump installer has equipment to lift the string and the cover. Your installer can lift the string a short distance, and using a special clamp, can replace the old cover with the new cover and set it back onto the case. NO PRESSURE PIPE THROUGH THE COVER If your cover does not have pressure piping passing through it, you probably can perform the installation yourself if you are comfortable with simple plumbing tasks. You will also need to

3 disconnect your existing well pump wiring under the cover and reconnect it through the new cover. This may require installing electrical flexible conduit, connecting electrical fittings and reconnecting the pump wiring. It is important that you can safely eliminate the possibility of power being applied to these lines while you are working on them. These are usually 240 volts. ELECTRICITY CAN KILL! DO NOT ATTEMPT TO PERFORM ELECTRICAL ALTERATIONS UNLESS YOU KNOW WHAT YOU ARE DOING. If you have the skills described, the installation is really quite simple. Most of the work is in changing over the well cover. Setting the pump requires approximately three to five minutes per nine foot section. Section 2: Inspecting Your Existing System. In this section you will remove your existing cover and inspect your well for any obstacles that might obstruct the installation of your new hand pump. a) Make certain that your electric well power source has been shut off and locked off. You will probably be a considerable distance from the power shutoff and the possibility of the power inadvertently being turned on must be eliminated. b) Remove your existing cover. There are so many styles; you will have to figure this one out on your own. c) Untangle any wiring under the cover and pull the wires from the pump tight, with the excess out of the case. d) Using a mirror reflecting the sun (don't laugh it's the best way), shine down the casing. If you have a straight well, you can see the water reflecting as deep as 200 feet. About 4 feet below the ground level you will see the special fitting (called a "pitless adapter") which takes your pressure piping to your house. The piping to the hand pump will pass right beside this fitting. On some installations, "torque arrrestors" are installed to keep the pipe and wiring at the center. Certain versions of these might prevent the hand pump piping from passing to the water level, in which case a pump installer can remove the unneeded ones. Torque arrestors are only necessary at the electric pump. The Simple pump will be installed 20 to 100 feet above the electric pump. Now that you have determined that you have a relatively unobstructed path to the water, you can proceed. Section 3: Replacing The Existing Well Cover. Tools: Wire cutters, strippers, Allen wrench set. a) When you untangled the pump wiring, you should have found connections. Typically these are wire nuts under electrical tape. They may be crimped connectors, in which case you will need to cut the wires close to the connectors. You will usually have three wires and sometimes four. Note the colors and disconnect them. As an additional safety precaution, take the bare wire ends coming from the house and touch them to the well case one at a time as you disconnect them. If for some reason there were power, they would arc against the case and not you. The wires must reconnect in the same order.

4 You may need to tie some twine onto the pump wires to keep them from falling down the well. The wires should however be taped to the piping a few feet down. b) Inspect the outer rim of the well case. Your new cover (P9) is made to fit either a standard 4", 5", 6" or 8" pipe. The case should measure either 4 5/8, 5 5/8, 6 5/8" or 8 5/8" on the outside diameter. Three holes are in the cover(p9); one where the split flange (P10) is located, one 1" threaded hole for the electrical, and a 1 _" hole for a pressure pipe for an existing submersible pump if it is routed through the cap (see previous section heading "PRESSURE PIPE THROUGH THE COVER"). Any unused holes should be plugged when the installation is complete with the plugs provided with the cover (P9). Your new cover(p9) has 1/16" clearance Well drillers often leave torch slag on the case. This needs to be removed if it protrudes beyond the outside diameter. A sharp flat file will remove it. A hand grinder will also work very quickly. c) Taking the wiring from inside the case, pass the wires through the 1" threaded port in the new cover(p9). Now slide the cover (P9) over the case, level if necessary and tighten the four outer set- screws. d) You will need to carefully evaluate your wiring to determine the best method to enclose the wiring. Sometimes flexible conduit is the easiest method. However you finish off the electrical conduit, make certain that the wiring is reconnected in the same order as the original. Also make certain that the wiring inside the case does not obstruct the path for the hand pump piping as you look down through the split flange (P10). Once your existing wiring is reconnected, you can energize your electric pump and make sure that it is working normally before you proceed. The hardest part is done. Section 4: Pump Cylinder, Drop Pipe Installation. In this section we will review the installation of the entire string of new drop pipe with the pump cylinder at the bottom. Being extremely cautious during this sequence is critical. Dropping the entire pipe string down the well is easy. They are almost impossible to retrieve. Follow these directions! Tools, supplies: Two pairs of channel locks, safety tool (P11), Teflon plumber's tape, bleach/water 1part bleach 24 parts water. Before starting, let's identify and organize the parts that we will need. The drop pipes are all identical except the one that will be used on the top (D5). This one has male threads on both ends. The top end has 1 1/4" pipe threads on a fitting. a) Lay out all of your pipes with the capped ends away from you. Now take the fiberglass sucker rod (D2) and slide one into each pipe (male end out) until it bumps the plastic cap, including the top drop pipe (D5). b) Take the pump cylinder (P1) over to one of the standard drop pipes (D1) and remove the end cap (on the male end of the drop pipe) and screw together the fiberglass sucker rod with steel pump rod protruding out of the pump cylinder. Tighten with two pairs channel locks until snug, being careful to only grip the metal portions of both rods and not the fiberglass. DO NOT CRUSH EITHER THE STAINLESS STEEL FITTING ON THE FIBERGLASS SUCKER ROD OR THE FIBERGLASS ITSELF! c) Apply the Teflon tape to the threads on the male end of the drop pipe (D1) and thread the drop pipe into the pump cylinder. Be careful not to cross thread. Tighten with two pairs of channel locks.

5 d) Pour the bleach solution over the pump cylinder. (Watch your clothes.) e) (Two persons) Now stand the assembly on end with the pump cylinder at the bottom and, insert the assembly into the new well cover through the split flange (P10). When the pump passes through the port, slide the safety tool over the pipe and let it lay on the split flange. As the pipe is lowered, the safety tool will stop the drop pipe at the coupling. You can now let loose. f) You should be looking at a coupling with a rod protruding about 4" out. (The rod should be pushed to the bottom if it is not already there.) Now take a sucker rod guide (D3) and slide it over the protruding rod and into the coupling. You are ready for the next section of drop pipe. g) Take another section of standard drop pipe (D1) with the sucker rod inserted and stand on end with the plastic cap down. With one person holding the pipe upright over the coupling in the cover, the other can remove the plastic cap and align the sucker rods. Thread both together making sure they are not cross-threaded and tighten with two pairs of channel locks, being careful not to grip the fiberglass portion of the sucker rod and not crushing the stainless steel fittings on the ends. Apply Teflon tape to the male threads and thread the pipe into the coupling and tighten with two pairs of channel locks. Do not let the coupling spin on the safety tool, as it can work its way out. Lift the pipe string while the other person removes the safety tool. As soon as the coupling passes through the port, reinsert the safety tool and hold it until the next coupling approaches. As the next coupling nears the safety tool, the other person can grab the sucker rod and pull upward helping to support the load and to keep the other person from pinching his fingers as the coupling comes into contact with the safety tool. This process is repeated for each section of standard drop pipe. When you suspect that you might be near your water level, pull up on the sucker rod at any time. If you are not in the water yet, the rod will fall very quickly. When you are in water, the rod will fall more slowly. Sometimes, as the pipe is lowered, a gurgling sound can be heard when the pump is in water. You can also stroke the rod repeatedly and water will be pumped up the string. If you are in water, it will become harder to stroke after ten strokes or so. The pipe string is also much heavier with water in it. h) When you are ready for the top drop pipe, install it just like the others. Lower this one down to the safety tool like the others. Section 5: Pump Head Installation. In this section we will review the installation and assembly of the pump head. Tools, supplies: Two pair of channel locks. a) Find the 3/4" diameter top pump rod (P3) and thread it onto the sucker rod (D2) at the well cover. With a pair of channel locks, grip the 3/4" steel rod only near its end, being careful not to mar the finish of the steel rod. Tighten with two pairs of channel locks until snug. b) Attach the lever bracket (P4) to the pump head with the 1/4" Allen screw provided. The straight side of the bracket should be at the top. c) Apply Teflon tape to the male thread at the top of the drop pipe string. Slide the pump head over the 3/4" shaft and align and thread onto the top drop pipe (D5). Make sure the pump head is perfectly vertical. This part is easy to cross thread. While holding the D5 coupling with a pair of channel locks, the other person can tighten by turning the top of the pump head.

6 d) Now with a 1/4" Allen wrench, find the clamping screw inside the split flange. Lift and remove the safety tool and lower the pump head into the split flange. This is a snug fit. Rotate the assembly clockwise and the pump will work its way through the split flange. Continue lowering the pump head body (P2) through the well cap split flange (P10) until pump head is at a convenient height. Tighten the split flange clamping screw. For Model 100T (T Handle) simply connect the "T" handle to the top 3/4" shaft. For Model 100L (Lever handle) see below e),f) and g). e) Attach the clevis (P7) to the top pump rod (P3) and tighten while gripping the shaft only near the end, next to the clevis. f) Slide the link arm (P5) over the lever bracket (P4) aligning the holes. Insert the pivot pin (P8). These go in a little hard. A little Vaseline on the tip helps. g) Assemble the lever (P6) to the lever link arm (P5) and clevis (P7) using the remaining pivot pins. You are ready to pump water! Section 6: Pumping Water. Finishing Touches. It will require about one stroke for each foot of water depth to get the water up to the pump head initially. 100 feet will require about 100 to 120 strokes. There is a very small bleeder hole (1/32 of a inch) about 8 feet below your pump head, in the top drop pipe. This takes about 15 minutes to drain and protects the pump against freezing. Each time you go out to pump after a period of time, it will require about six to 10 strokes to get the water back to the pump head. The check valves in the pump cylinder allow a very small amount of leakage over time. Over several days or weeks, you may need to pump a few extra strokes to get the water back to the top. Pressure Piping: The outlet nipple has hose threads on one side and 3/4" pipe threads on the other. This allows for a variety of possible piping configurations from the outlet. If you intend to pressurize your house pressure tank from the hand pump, we recommend that a check valve be installed so that the freeze protection drain will not drain off your house pressure. Also make sure that a relief valve is installed somewhere in the system to prevent overpressuring. The Simple pump can deliver well over 100 PSI, which may damage your house plumbing if protection is not provided. In climates where freezing occurs, protection will need to be provided to prevent the pump from freezing if piped from the outlet.

7 Contents Introduction Specifications Warranty Assembly Procedure for Model GM100 Gear motor 1/10 and 1/5 H.P. models Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Unpacking, Inspection Preparing Your Existing Pump Gear motor Mounting Electrical Connection Operation Maintenance Introduction Thank you for purchasing your GM100 gear motor assembly. The model GM100 is designed to be used with either the 100L or 100T hand pump. When assembled onto the model 100 pump, the gear motor is capable of delivering 1/2 to 2 gallons per minute of water from as deep as 240 feet. The gear motor must be powered by a 12 volt, direct current power source such as a marine or automotive battery. Precaution must be taken to prevent operation under low voltage conditions below 11.5 volts. Tools required: One 3/16 hex Allen wrench preferably a T handle; One small Phillips screw driver. Specifications: Motor size: 1/10 HP Output Torque Capacity: 75 in/lbs. Nominal Output RPM: 57 Full Load Motor Current: 9.0 amps (1/10h.p.) or 18.0 amps (1/5h.p.) (Full load is the upstroke - average load is 50-60% of full load) Allowable Voltage Range: 11.5 to 15 Volts dc Shipping weight: 23 lbs. Warranty: The gear motor assembly is warranted against defective materials and workmanship for a period of 1 year from the date of purchase. The motor load must not be exceeded and any routine maintenance recommended in the instructions must be adhered to. Section 1: Unpacking, Inspection Carefully remove the gear motor assembly from the shipping box, along with a small plastic bag of screws and spare fuses. Using a Philips screw driver remove the two small screws attaching the cover. Remove the cover and lift out the large aluminum yoke. You should have all of the components shown in Fig. 1. The plastic bag should have 4 Allen screws and three spare fuses.

8 Fig. 1 Section 2: Preparing Your Existing Pump Your hand pump should already be installed and pumping water without any binding and with a smooth operation prior to attempting to install the gear motor. You should confirm that your pump is delivering at least one gallon of water with approximately 25 strokes with the lever handle system (model 100L). If you have the model 100T you should be getting one gallon in about 14 complete strokes. Once proper pumping function is confirmed, remove all hardware on the top of the pump head so that your pump looks like the Fig. 2. Also, push the pump rod fully down. It should be no higher than 3-3/4 from the top of the head to the shoulder as shown in the figure. Fig. 2 Section 3: Gear motor Mounting a) Using a 3/16 hex Allen wrench remove the crank arm roller as shown in Fig. 3. b) Screw on the yoke to the top of the pump rod (Fig 4). Hold the pump rod as high as

9 possible with adjustable pliers and tighten the yoke. Tapping with a rubber mallet works well. c) Attach the entire assembly to the pump head using the four screws provided (Fig. 5). Leave the screws very lightly tightened. Lift the pump rod as shown in Fig. 6. Make sure that the movement is smooth and does not bind. The clearance in the mounting holes provides a small amount of movement in the gear motor. Make small adjustments to the gear motor mounting, bumping it from side to side until the pump rod strokes up and down freely (Fig. 6). This step is very important. If the pumping motion is not free at this stage, the gear motor will not pump freely. d) Reinstall the cam roller in the closest hole to the center (Fig. 7). Do this by lifting the pump rod until the roller can be installed in the correct position. Fig. 4 Fig. 5

10 Fig. 6 Fig. 7 Section 4: Electrical Connection The two wires coming out the bottom of the gear motor are to be supplied with 12 volts dc power. Make sure that your supply wiring is at least 16 gauge and can maintain a minimum of 11.5 volts with the motor at a full load of 9 Amps. The red wire is the positive (+) power lead and the black is the negative (-). When working on the power connection, put the switch next to the motor in the off (push on the bottom side) position and remove the fuse (push and turn counter-clockwise). Provisions need to be made in your power supply to prevent operation of the motor when voltage is below 11.5 volts, such as when a battery is nearly discharged. Section 5: Operation a) Once the power has been connected, reinstall the fuse and attach the cover shown in Fig. 8. On the break-in period, leave the pump outlet open or pumping through a garden hose unrestricted. Make sure that nothing is setting on top of the gear motor. Turn on the switch which will initiate the pumping action. With the stroke setting at the shortest position, the pump will only generate about 3/4 gallon per minute. The pump should run for at least two hours at this setting to facilitate break- in. b) Once the pump has run for two hours at the first stroke setting, disconnect the power, open the cover and move the roller to the next position. Run the pump for two hours at each setting. When you reach a setting that causes the fuse to blow, you know that you have exceeded the motor limit. Move the roller back to the previous setting. This will be the maximum pump rate for your well conditions. If you connect your pump to pressurize a house system or to an elevated storage tank, you will need to determine the optimum stroke setting using the same method as above, but under actual maximum pressure conditions.

11 Fig. 8 Flow Capacities and Pressures : Maximum Total Head Flow Rate GPM Pump Stroke Setting 1/10h.p. - 1/5h.p. motor 240 feet (104 psi) " 160 feet (69 psi) " 126 feet (54 psi) " 92 feet (43 psi) " 76 feet (33 psi) " Section 6: Maintenance, Trouble Shooting As long as the gear motor system is pumping correctly and not causing the motor to overload, no maintenance is required. If the mechanism experiences a bearing failure for any reason the motor protection fuse will blow. It is extremely important to replace the fuse with only a 10 amp quick blow 1/4 x 1-1/4. Using a larger fuse will overheat the motor and damage the gears. The motor normally operates at around 100 to 110 degrees F. If the fuse has blown for any reason, remove the cover and remove the crank arm roller. Lift the yoke up and down by hand. How freely the yoke moves or does not move is an indication of what the motor is working against. Typical reasons for difficult movement: a) Misalignment of the gear motor assembly. Loosen the four attaching screws on the pump head and make sure that the assembly is aligned before re-tightening. Make sure that there is no metal to metal contact except at the rollers. b) Seized roller: Check both rollers for free movement. c) Pump binding: Remove the gear motor and stroke the pump rod by hand. It should require about 40 pounds of lifting effort for each 100 feet of water level. If the effort is any more than this, remove the pump head and try again to determine if the problem is in the head. After this check routine, reassemble the system and repeat the startup procedure.

INSTALLATION PROCEDURE FOR MODEL ADA100 ROTARY HAND PUMP

INSTALLATION PROCEDURE FOR MODEL ADA100 ROTARY HAND PUMP INSTALLATION PROCEDURE FOR MODEL ADA100 ROTARY HAND PUMP (The following instructions are very detailed, and should tell you everything you need to know. If you have questions, please phone 775-265-1220.)

More information

The Water Pump Guy Your Authorized Dealer/Installer for Simple Pump Co

The Water Pump Guy Your Authorized Dealer/Installer for Simple Pump Co The Water Pump Guy Your Authorized Dealer/Installer for Simple Pump Co Installation and Maintenance of the Hand-Operated Simple Pump THE WATER PUMP GUY 775.450.1990 PO Box 189 Gardnerville, NV 89410 thewaterpumpguy.com

More information

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP LAST UPDATED: January 10, 2019 It is highly recommended you view the entire installation video for an overview before using these instructions. http://www.simplepump.com/support/installation-videos/

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : GTL 1110 1900-0510 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C.,

More information

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP

INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP INSTALLATION OF THE HAND-OPERATED SIMPLE PUMP LAST UPDATED: June 25, 2018 We recommend you view the installation video for an overview, before using these instructions. If you are a homeowner, we recommend

More information

Go-ped ESR750 / ESR750EX Rear Brake Installation Instructions

Go-ped ESR750 / ESR750EX Rear Brake Installation Instructions Go-ped ESR750 / ESR750EX Rear Brake Installation Instructions This kit provides all the parts you need to install a rear brake on your ESR750 or ESR750EX. It will not work on an ESR Sport, or other Go-ped

More information

Ford C4 and C6 Floor Mount Automatic Transmission Shifter Installation Instructions

Ford C4 and C6 Floor Mount Automatic Transmission Shifter Installation Instructions Ford C4 and C6 Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Ford C4 and C6 Mount

More information

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components Page 1 Introduction The M-8200 Precision Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options with

More information

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source) Part# 18-1819 JL AIR IT UP 4 Tire On Board Air Delivery System (Requires External Air Source) The most up-to-date instructions always visit www.updownair.com www.updownair.com 833-226-4863 I M P O R T

More information

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit Tools Required 5 / 32 Hex key 5 / 16 Hex key 7 / 64 Hex key Standard screwdriver Pair of external snap ring pliers Rubber mallet Hammer

More information

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Blvd. Dagenais West LAVAL (QUEBEC) CANADA H7L 5X9 MODELS 503132S 503332 503232S 503732 TEL : 514.337.4415 FAX : 514.337.4029 info@burcam.com Your pump has

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : GRL 1110 1900-0540 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

Powerglide Automatic Floor Mount Shifter Installation Instructions

Powerglide Automatic Floor Mount Shifter Installation Instructions Powerglide Automatic Mount Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 (865) 966-2269 FAX (865) 671-1999 tech@lokar.com www.lokar.com Powerglide

More information

ALL AMERICAN BILLET. Front Drive System - Small Block Ford Installation Instructions

ALL AMERICAN BILLET. Front Drive System - Small Block Ford Installation Instructions ALL AMERICAN BILLET Front Drive System - Small Block Ford Installation Instructions Small Block Ford with AC & PS All American Billet Store (800) 764-0926 www.allamericanbilletstore.com Items needed for

More information

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS Model T033 CONVERTIBLE JET PUMP /HP 900 GPH Suction lift Head of 5 (7.5m) in shallow well mode Professional Series YEAR WARRANTY Suction: /4 Discharge: NPT Maximum pressure: 85 PSI US GPH LPH 5 900 3400

More information

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate (Refer to qualified

More information

Chrysler 727, 904, 518 Floor Mount Automatic Transmission Shifter Installation Instructions

Chrysler 727, 904, 518 Floor Mount Automatic Transmission Shifter Installation Instructions Chrysler 727, 904, 518 Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Release Button

More information

Final Assembly Instructions: Runaround Cruiser

Final Assembly Instructions: Runaround Cruiser Final Assembly Instructions: Runaround Cruiser Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our expert

More information

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)

More information

A B C D E F. Tools Required (supplied by others)

A B C D E F. Tools Required (supplied by others) Page 1 of 17 Parts List Below Deck Automatic Retractable Security Cover Kit (1) Tube End Bearing Plate (A) (1) Rope Reel and Cover Drum Motor Assembly (B) (1) Cover Drum (1) Pulley Support Channel (2)

More information

PORSCHE 928. PKT Installation 1.8. No air pump version. Air pump version

PORSCHE 928. PKT Installation 1.8. No air pump version. Air pump version PORSCHE 928 PKT Installation No air pump version Air pump version 1.8 Tools Torque wrench 10mm socket 12mm socket 13mm socket 5mm allen socket 6mm allen socket 8mm allen key Caliper Supplies Blue Loctite

More information

Front Drive System - Big Block Chevy Installation Instructions Big Block Chevy with AC & with PS

Front Drive System - Big Block Chevy Installation Instructions Big Block Chevy with AC & with PS Front Drive System - Big Block Chevy Installation Instructions Big Block Chevy with AC & with PS All American Billet Store (800) 764-0926 www.allamericanbilletstore.com Items needed for install Jack Jack

More information

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction...

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction... 1 CONTENTS Product Features and Specifications... 3 Installation Requirement... 5 Installation... 6 Exploded View... 20 Test... 22 Operation Instruction... 25 Maintenance... 26 Trouble Shooting... 27 Parts

More information

CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL

CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL 2 Table of Contents Section 1: General Information Page Handle Assembly Instructions 4 Maintenance All Models 6 Oil Change Procedures All Models 9 Height Adjustment

More information

Pontoon Assembly Instructions and manual. Read before using hoist.

Pontoon Assembly Instructions and manual. Read before using hoist. Page 1 Pontoon Assembly Instructions and manual. Read before using hoist. For Models 32BL18, 32BL22, 32BL25 and 42BL28 R Model 32BL22 Shown Proudly Made in Michigan By NuCraft Metal Products 402 Southline

More information

Installation Instructions Z-Gate Shifter

Installation Instructions Z-Gate Shifter Installation Instructions Z-Gate Shifter Part Number 80681 1998, 2001 by B&M Racing and Performance Products The B&M Z-Gate shifter can be used in vehicles equipped with most popular three speed automatic

More information

Wiring checks below assume the vehicle is in reverse, secured so it won't roll, and key is on so backup lights are illuminated:

Wiring checks below assume the vehicle is in reverse, secured so it won't roll, and key is on so backup lights are illuminated: Reverse Lockout Troubleshooting The way that the backup solenoid works is: When the backup lights are lit on your tow vehicle, 12 volt power should come down the blue wire through the trailer connector

More information

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS WITH HYDRAULIC CONTROL PACKAGE PART NUMBER: SE-023 REVISION:

More information

Installation, Maintenance and Service Manual Power Cord

Installation, Maintenance and Service Manual Power Cord Installation, Maintenance and Service Manual Power Cord 45-081, REV. 8/14 1 of 8 Table Of Contents Section 1 Installation Procedure... 3 1.1 General...3 1.2 Sheave installation...4 1.3 Anchor installation...4

More information

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

More information

( Versions Available)

( Versions Available) STYLE 494 ELECTRIC LADDER PIPE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS ( Versions Available) The following is intended to provide the basic instructions for installation, operating and maintenance

More information

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

More information

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS -S INDICATES CYLINDERS ARE IN TANDEM PART NUMBER: 100121 REVISION "A" ECN

More information

1200 Southeast Ave Tallmadge, Ohio to 2014 Mustang (V6 & V8) Summit Racing Roll Stop Install Instructions.

1200 Southeast Ave Tallmadge, Ohio to 2014 Mustang (V6 & V8) Summit Racing Roll Stop Install Instructions. 1200 Southeast Ave Tallmadge, Ohio 44278 2010 to 2014 Mustang (V6 & V8) Summit Racing Roll Stop Install Instructions Part # SUM-760005 Thank you for considering the Summit Racing Roll Stop. Summit Racing

More information

Manifold Isolation Valves

Manifold Isolation Valves 300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

Final Assembly Instructions: Bikes with Threadless Headsets

Final Assembly Instructions: Bikes with Threadless Headsets Final Assembly Instructions: Bikes with Threadless Headsets Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping,

More information

Z-Gate Universal Shifter

Z-Gate Universal Shifter Installation Instructions Z-Gate Universal Shifter Fits: GM, Ford, Lincoln and Chrysler Transmissions See Application Guide for Specific Applications Part #80681 Rev 06/01/2018 WORK SAFELY! For maximum

More information

RS4000 Setup. Before you install the RS4000 system, check to ensure that nothing was damaged or lost during shipping.

RS4000 Setup. Before you install the RS4000 system, check to ensure that nothing was damaged or lost during shipping. RS4000 Setup Before you install the RS4000 system, check to ensure that nothing was damaged or lost during shipping. If anything is damaged or missing, contact your salesman immediately. Mount Components

More information

Installation instructions for Camaro/Firebird and Nova* Windshield Wiper Systems

Installation instructions for Camaro/Firebird and Nova* Windshield Wiper Systems Installation instructions for 1967-69 Camaro/Firebird and 1968-74 Nova* Windshield Wiper Systems The Raingear 1967-69 Camaro/Firebird and 1964-74 Nova wiper system is designed for ease of installation

More information

INSTRUCTION G-Comp Unser Edition Rear Suspension: Chevy Nova. Kit Contents:

INSTRUCTION G-Comp Unser Edition Rear Suspension: Chevy Nova. Kit Contents: INSTRUCTION 350-400 G-Comp Unser Edition Rear Suspension: 62-67 Chevy Nova Speedway Motors, Inc. 2017 Kit Contents: 350003.1 G-Comp Chassis Brace 350003.2 G-Comp Front Support 350400.1 Chevy II Unser Rear

More information

3875 Cypress Drive Petaluma, CA Fax

3875 Cypress Drive Petaluma, CA Fax 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with Fixed Angle Front End for Flat Panel / Keyboard Bracket (L Brackets

More information

MM Rear Coil-Over Kit - Bilstein Shocks (MMCO-3)

MM Rear Coil-Over Kit - Bilstein Shocks (MMCO-3) 3430 Sacramento Dr., Unit D San Luis Obispo, CA 93401 Telephone: 805/544-8748 Fax: 805/544-8645 www.maximummotorsports.com MM Rear Coil-Over Kit - Bilstein Shocks (MMCO-3) Read all instructions before

More information

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3 Page 1 Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3 Please Note: It is preferable to park on a flat surface, as you will have to engage and disengage

More information

PRO RATCHET UNIVERSAL SHIFTER

PRO RATCHET UNIVERSAL SHIFTER Installation Instructions PRO RATCHET UNIVERSAL SHIFTER Fits: GM, Ford and Chryslers w/automatic Transmission See Application Guide for Specific Vehicles Catalog # 80842 WORK SAFELY! For maximum safety,

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

A B C D E F. b.tools Required (supplied by others) 3/16 Drill Bit 3/8 Wrench Phillips Head Screwdriver Page 1 of 13 5E.1 Parts List a. Below Deck Automatic Retractable Security Cover Kit (1) Tube End Bearing Plate (A) (1) Rope Reel with Motor Attached (B) (1) Rope Reel Cover (C) (1) Cover Drum (1) Cover

More information

MODEL H INSTALLATION INSTRUCTIONS

MODEL H INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your unit has been carefully packaged at the factory to prevent damage during shipping.

More information

CI 3000 Coil Inserter

CI 3000 Coil Inserter CI 3000 Coil Inserter Setup & Operator Manual Issue 1 April 02 Performance Design Inc. The CI 3000 plastic spiral inserter will bind books up to 1-1/8 (28.6mm) thick using coil diameters from 3/16 (5mm)

More information

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP Model T03121 SHALLOW WELL JET PUMP Professional Series 2 YEAR WARRANTY 1/2HP 916 GPH Head of 25 (7,5 m) US GPH LPH Suction: 1 1/4 NPT Discharge: 1 NPT Maximum Pressure: 65 PSI Stainless steel shaft and

More information

GM Floor Mount Automatic Transmission Shifter Installation Instructions

GM Floor Mount Automatic Transmission Shifter Installation Instructions GM Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com GM Mount Automatic Transmission

More information

Installationn Instruction Manual

Installationn Instruction Manual Table of Contents Supplied Kit Parts.Page 2 Required Tool List Page 2 Step by Step Installation Instructions Pages 3-6 Battery Requirements.Page 6 Operation Page 7 Maintenance Page 7 Wiring Diagrams..Page

More information

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website INSTALL MANUAL FOR ON LINE ORDERING- E Commerce Visit Our Website WWW.PRESSUREGUARD.COM Contact Information Technical Support: Chris@pressureguard.com Sales Support: Sales@pressureguard.com By Phone: 615-227-6024

More information

INSTALLATION INSTRUCTIONS FORD F-150 2WD & 4WD RETAINS FACTORY TOW HOOKS PART #P3063

INSTALLATION INSTRUCTIONS FORD F-150 2WD & 4WD RETAINS FACTORY TOW HOOKS PART #P3063 INSTALLATION INSTRUCTIONS FORD F-150 2WD & 4WD RETAINS FACTORY TOW HOOKS PART #P3063 PARTS LIST: 1 Grille Guard 2 10-1.5mm Nylon Lock Nuts 1 Driver/Left Frame Mounting Bracket 4 12mm Plastic Washers 1

More information

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems Instruction Sheet 408-8040 30 NOV 17 Rev H Ram Assembly Ram Post Locking Screw Stock Drag Drag Release

More information

COYOTE ENTERPRISES, INC. 9/10 BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

COYOTE ENTERPRISES, INC. 9/10 BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL COYOTE ENTERPRISES, INC. 9/10 BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL Parts & Machinery for the Abrasive Blast Industry 27301 East 121st Street Coweta, Oklahoma 74429 (918) 486-8411 Fax (918) 486-8412

More information

Technical Support (707)

Technical Support (707) Installation Instructions UNIMATIC SHIFTER Fits: GM, Powerglide, Ford and Chrysler Transmissions See Application Guide for Specific Vehicles Catalog # 80775 WORK SAFELY! For maximum safety, perform this

More information

Page 1. File: Motolight caliper one-piece Harley Date: 8/15/2006

Page 1. File: Motolight caliper one-piece Harley Date: 8/15/2006 Page 1 Harley-Davidson FL Caliper Mount Installation One-piece mounting brackets You should allow about two to three hours for installation. We suggest you use a well-lighted space for installation. PLEASE

More information

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # 20100742 TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON

More information

2 Wire Plus Ground 3 Wire Plus Ground IL0655

2 Wire Plus Ground 3 Wire Plus Ground IL0655 4 INCH SUBMERSIBLE WELL PUMP 2 & 3 Wire 2 Wire Plus Ground 3 Wire Plus Ground Español p. 21 For installation videos and other information, scan with your smart phone. Or, visit: starwatersystems.com and

More information

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of

More information

Chrysler 727, 904, and 518 Automatic Trans Mount Shifter Installation Instructions

Chrysler 727, 904, and 518 Automatic Trans Mount Shifter Installation Instructions Chrysler 727, 904, and 518 Automatic Trans Mount Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Chrysler 727, 904, and

More information

Page 1. File: Motolight caliper one-piece Date: 8/14/2006

Page 1. File: Motolight caliper one-piece Date: 8/14/2006 Page 1 Caliper Mount Installation One-piece mounting brackets You should allow about two to three hours for installation. We suggest you use a well-lighted space for installation. PLEASE READ ALL THE INSTRUCTIONS.

More information

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance OPERATION: (01-10) The Onyx series DAC-PFO pinch valve fails open on loss of air. This simple spring and air bag arrangement that drives a pair of

More information

Electric Trolling Motor

Electric Trolling Motor Electric Trolling Motor L Series User s Manual Please read and retain this manual before using product REACH RoHS TABLE OF CONTENTS Contents GENERAL INFORMATION 4 SPECIFICATIONS 4 WIRING AND BATTERY RECOMMENDATIONS

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-1088 03-16 Model 1088 Vacu-Gard Blanketing Valve ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1088 Vacu-Gard is a tank blanketing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Part# 69-0717 AIR IT UP 4 Tire On Board Installed Air Delivery System with Rear Mounted Controller (Requires External Air Source) For the most up-to-date instructions please visit

More information

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908 DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS

More information

INSTALLATION GUIDE. AV8900H Dual Multimedia Headrest Replacement System

INSTALLATION GUIDE. AV8900H Dual Multimedia Headrest Replacement System INSTALLATION GUIDE AV8900H Dual Multimedia Headrest Replacement System NOTICE OF INTENDED INSTALLATION AND USE AV8900H VIDEO PRODUCTS ARE NOT INTENDED FOR VIEWING BY THE DRIVER, AND ARE TO BE INSTALLED

More information

READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION

READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION INSTALLATION INSTRUCTIONS Hot Fox In-Tank Fuel Warmer READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION Models covered by these instructions include: HFG 0-0 HFG 0- SHFT--0- SHH--0 TWHF 0- HFG

More information

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks TITAN pt. no.: 01 0000 0119 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

JEEP JK4 STEP SLIDER INSTALLATION BD-SS-100-JK4

JEEP JK4 STEP SLIDER INSTALLATION BD-SS-100-JK4 JEEP JK4 STEP SLIDER INSTALLATION BD-SS-100-JK4 PARTS LIST QTY DESCRIPTION 1 Drivers Side Slider Assembly 1 Passenger Side Slider Assembly 1 Wiring Harness and Fuse 1 Double Sided Sticky Squares and Alcohol

More information

ASSEMBLY INSTRUCTION MANUAL

ASSEMBLY INSTRUCTION MANUAL ASSEMBLY INSTRUCTION MANUAL 500, 600, 660, 5010, 6010 & 6610 Snowblower Electric Spout Rotation Kit Instructions 122013 P4710 Electric spout rotation kit is to be used in place of a hydraulic or hand

More information

Type N550 Snappy Joe Emergency Shutoff Valves

Type N550 Snappy Joe Emergency Shutoff Valves Instruction Manual MCK-1149 Type N550 March 2010 Type N550 Snappy Joe Emergency Shutoff Valves Failure to follow these instructions or to properly install and maintain this equipment could result in an

More information

INSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES

INSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES INSTALLATION INSTRUCTIONS 4880 Auto Level Compressor Kit Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY BEFORE STARTING YOUR INSTALLATION IMPORTANT NOTES

More information

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A Installation Manual AutoSteer Gleaner Combine AutoGuide 2 Steer Ready Supported Models A66 A76 R66 R76 S67 S77 PN: 602-0312-01-A LEGAL DISCLAIMER Note: Read and follow ALL Instructions in this manual carefully

More information

(Refer to qualified personnel)

(Refer to qualified personnel) 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com Installation Guide VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm (Slide-Above-Arm Configuration)

More information

Ford AOD-4R70W-AODE Cable Operated Shifter Installation Instructions

Ford AOD-4R70W-AODE Cable Operated Shifter Installation Instructions Ford AOD-4R70W-AODE Cable Operated Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Ford AOD-4R70W-AODE Cable

More information

ARMAGEDDON tm BY AIR AMERICA, INC.

ARMAGEDDON tm BY AIR AMERICA, INC. ARMAGEDDON tm BY AIR AMERICA, INC. Congratulations! You have purchased the most advanced high-pressure Air/Nitrogen Paintball system available to the Paintball World. Your Air America ARMAGEDDON tm is

More information

BASIC TROUBLE SHOOTING (PERFECTPASS FOR MECHANICAL ENGINES) How PerfectPass Works

BASIC TROUBLE SHOOTING (PERFECTPASS FOR MECHANICAL ENGINES) How PerfectPass Works BASIC TROUBLE SHOOTING (PERFECTPASS FOR MECHANICAL ENGINES) How PerfectPass Works Through the in-dash display the driver sets the desired boat speed or engine RPM depending upon which mode of operation

More information

DODGE OFF ROAD T-STYLE STEERING KIT INSTALLATION INSTRUCTIONS

DODGE OFF ROAD T-STYLE STEERING KIT INSTALLATION INSTRUCTIONS Dodge Off Road, LLC Specializing in Dodge Ram Solid-Axle 4x4 Suspension and Steering for Off Road Applications 855.9009.DOR sales@dodgeoffroad.com dodgeoffroad.com DODGE OFF ROAD T-STYLE STEERING KIT INSTALLATION

More information

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using

More information

PORSCHE 928. PKT Installation 1.6. No air pump version. Air pump version

PORSCHE 928. PKT Installation 1.6. No air pump version. Air pump version PORSCHE 928 PKT Installation No air pump version Air pump version 1.6 Tools Torque wrench 10mm socket 12mm socket 13mm socket 5mm allen socket 6mm allen socket 8mm allen key Caliper Supplies Blue Loctite

More information

Installation Instructions

Installation Instructions Powerglide Automatic Trans Mount Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 (865) 966-2269 FAX (865) 671-1999 tech@lokar.com www.lokar.com Powerglide

More information

Fisher 657 Diaphragm Actuator Sizes and 87

Fisher 657 Diaphragm Actuator Sizes and 87 Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting

More information

GRAIN CART RETROFIT BOLT-ON TYPE HITCH SCALE SYSTEM

GRAIN CART RETROFIT BOLT-ON TYPE HITCH SCALE SYSTEM GRAIN CART RETROFIT BOLT-ON TYPE HITCH SCALE SYSTEM Instructions This manual is copyrighted by Scale-Tec. Redistribution or copy of this manual or portions of this manual must be approved through Scale-Tec

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 2013-2014 Honda CBR500R/RA Tour Performance Handlebar Risers P/N: HR01087 IMPORTANT: PLEASE GIVE CUSTOMER ENCLOSED INFORMATION! Thank you for your purchase of our HeliBars. They

More information

Type 2 Push-Through 37 Ton Log Splitter. Assembly Manual

Type 2 Push-Through 37 Ton Log Splitter. Assembly Manual Type 2 Push-Through 37 Ton Log Splitter Assembly Manual Refer to this manual for the following models: RS37PT-LF09PC-16-1 RS37PT-LF09EC-16-1 RS37PT-LF09EC-16-2 RS37PT-LF13EC-22-1 RS37PT-LF13EC-22-2 RS37PT-LF15EC-22-1

More information

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL TABLE OF CONTENTS SYSTEM...... Warning........ Description...... Prior to Operation OPERATION... Main Components... Mechanical...

More information

STYLE 3463 FireFox. With Position Feedback Potentiometer

STYLE 3463 FireFox. With Position Feedback Potentiometer STYLE 3463 FireFox INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS With Position Feedback Potentiometer The following is intended to provide the basic instructions for installation, operating and

More information

Installation Instructions Pro Stick Shifter

Installation Instructions Pro Stick Shifter Installation Instructions Pro Stick Shifter Part Number 80701, 80702 & 80706 2012, 2010, 2008, 2001, 1998 by B&M Racing and Performance Products The B&M Pro Stick shifter #80701 and #80706 comes equipped

More information

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683 Installation Instructions QuickSilver Shifter Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683 WORK SAFELY! For maximum safety, perform this installation

More information

Ford C6 Automatic Trans Mount Shifter Installation Instructions

Ford C6 Automatic Trans Mount Shifter Installation Instructions Ford C6 Automatic Trans Mount Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Ford C6 Automatic Trans Mount Installation

More information

CORPORATION REPAIR MANUAL HWH SPACEMAKER ROOM EXTENSION SYSTEM NO LEVELING SYSTEM FOR NATIONAL RV NON-MOTORIZED VEHICLES

CORPORATION REPAIR MANUAL HWH SPACEMAKER ROOM EXTENSION SYSTEM NO LEVELING SYSTEM FOR NATIONAL RV NON-MOTORIZED VEHICLES HWH R CORPORATION REPAIR MANUAL HWH SPACEMAKER SYSTEM NO LEVELING SYSTEM FOR NATIONAL RV NON-MOTORIZED VEHICLES FEATURING: DUAL CYLINDER "RAIL" (WITH RACK SENSING VALVE) SINGLE CYLINDER DUAL CYLINDER "RAIL"

More information

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks TITAN pt. no.: 01 0000 0129 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts Installation Manual For High Speed Alumavator and Platinum 10 and 23 Degree Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all

More information

Procharger Stage II Intercooled Supercharger System (11-14 GT)

Procharger Stage II Intercooled Supercharger System (11-14 GT) Procharger Stage II Intercooled Supercharger System (11-14 GT) Installation Time: Approximately one day. Installed on 2012 Mustang GT 5.0/Manual Required Tools 3/8 Socket Set (Standard and Metric) 1/2

More information

Installation Manual. For. Hi-Speed Alumavator / Platinum Vertical Boat Lifts

Installation Manual. For. Hi-Speed Alumavator / Platinum Vertical Boat Lifts Installation Manual For Hi-Speed Alumavator / Platinum Vertical Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons that may operate

More information

Material required for drilled well application (indoor use only)

Material required for drilled well application (indoor use only) SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C

More information