Connectorized Cables Category 2, 3, and 5
|
|
- Piers Boyd
- 5 years ago
- Views:
Transcription
1 ategory 2, 3, and 5 D s connectorized cables are designed for voice and intermediate speed data applications. Each cable assembly is equipped with either two connectors or one connector and one stub. Specialty cables with two connectors on one end are also available. ll feature 24 WG (.5 mm) twisted pair cable covered with V jacket material. Features: Unshielded, shielded, and shielded plenum ategory 2, 3, and 5 cable assemblies 25 or 32 pair cable types, 12, or plug and receptacle connectors Solid tinned copper cable
2 Unshielded ables Unshielded cables are manufactured of solid tinned copper covered with V insulation. 12 / 218 Shielded ables Shielded cables are manufactured of solid tinned copper, covered with V insulation. Shielded cables include an aluminum polyester shielding ground wire. Shielded lenum ables Shielded plenum cables are manufactured of solid tinned copper with V insulation. Shielded plenum cables include an aluminum foil/mylar shielding ground wire. Low Smoke Zero Halogen (LSZH) ables rimarily specified in Europe per European Telecommunications Standards Institute (ETSI) guidelines, LSZH cables comply with building codes requiring low smoke emission standards. 2
3 ategory 2 and 3 ables With Standard onnectors atalog Number / 218 U S Unshielded Shielded* Shielded lenum *Shielded cable does not come with metal shell connectors. 2 3 ategory 2 ategory 3 First onnector Type able Type lug eceptacle First onnector ngle Features and enefits XXX Second onnector ngle X Second onnector Type S Length in Feet 1' increments up to 2' 5' increments from 2' to 1' 5' increments thereafter Note: 1 foot = 3.48 cm lug eceptacle Number of able airs 25 airs 32 airs ategory 2 cable can transmit data at speeds up to 4 Mbps ategory 3 cable is designed for 1aseT networks and can transmit data at speeds up to 1 Mbps Standard cables feature a plug or receptacle on one end with a plug, receptacle, or stub on the opposite end. onnectors are available in,, or angles. 3
4 ategory 5 ables With Standard onnectors atalog Number / 218 U S Unshielded Shielded* *Shielded cable does not come with metal shell connectors. able Type 5 ategory 5** First onnector Type lug eceptacle First onnector ngle XXX Second onnector ngle X Length in Feet 1' increments up to 2' 5' increments from 2' to 1' 5' increments thereafter Note: 1 foot = 3.48 cm Second onnector Type S lug eceptacle Number of able airs 25 airs 32 airs ** D s ategory 5 cable assemblies are designed to complement standard DSLM wiring schemes. Though the ategory 5 cable assemblies are manufactured using ategory 5 cable and connectors, the final cable assembly is not ategory 5 tested. Features and enefits ategory 5 cable can transmit data at speeds up to 1 Mbps Ideal for DSL applications Standard cables feature a plug or receptacle on one end with a plug, receptacle, or stub on the opposite end. onnectors are available in,, or angles. 4
5 Specialty ables With Y-ables These specialty cables feature a plug or receptacle on one end with a combination of two plugs, receptacles, or stubs on the opposite end. ommonly known as Y-cables, these cables support the interface between high and lower cable count equipment elements. Other types of specialty cables (e.g. dual-sided connectors) are available upon request. atalog Number / 218 U S Unshielded Shielded* *Shielded cable does not come with metal shell connectors. able Type 2 ategory 2 3 ategory 3 5 ategory 5** First onnector Type lug eceptacle First onnector ngle Number of able airs airs 32 airs XXX Length in Feet 1' increments up to 2' 5' increments from 2' to 1' 5' increments thereafter Note: 1 foot = 3.48 cm. Second onnector ngle X W X Y Z Equipment Wiring Scheme XX Second onnector Types The cable is configured to correspond to specific equipment wiring schemes. ontact D for details. eceptacle/eceptacle / lug/lug lug/eceptacle ** D s ategory 5 cable assemblies are designed to complement standard DSLM wiring schemes. Though the ategory 5 cable assemblies are manufactured using ategory 5 cable and connectors, the final cable assembly is not ategory 5 tested. Specialty Y-able 5
6 Specialty ables Low Smoke Zero Halogen (LSZH) ables rimarily specified in Europe per European Telecommunications Standards Institute (ETSI) guidelines, LSZH cables comply with building codes requiring low smoke emission standards. atalog Number L / 218 L LSZH 3 5 ategory 3 ategory 5 First onnector Type able Type lug eceptacle First onnector ngle ustom onnectors D can create custom connectorized cables to meet unique connectivity needs. For information regarding specialty dual-sided connectors and other customized cables, contact D. XXX S Specialty Dual-Sided onnector Second onnector ngle X Length in Feet 1' increments up to 2' 5' increments from 2' to 1 ' 5' increments thereafter Note: 1 foot = 3.48 cm Second onnector Type lug eceptacle Number of able airs airs 32 airs 6
7 Specifications 12 / 218 Loss (d) Unshielded, 25 air able MEHNIL onductors Type: lating: Insulation: Jacket Outer Diameter: FLMMILITY: ELETIL Dielectric Withstanding Voltage: urrent ating: Voltage ating: ENVIONMENTL Operating Temperature: Moisture esistance: 24 WG (.5 mm) Solid tinned copper 3 micro-inches of tin, minimum V,.6" thickness V,.3" thickness.37" able meets the requirements of Underwriters Laboratories, Standard 1581, vertical tray flame test (M ating). 5 Vrms per MIL-STD-22, method mps per conductor 3 Volts º to 4º 95% per MIL-STD-22, Method 16 Note: These are representative specifications for unshielded, 25 pair ategory 2 cable. omplete specifications for all products are available upon request eturn Loss 3 khz - 1 MHz Unshielded, 25 air able with onnector air 1 air 2 air 3 air 4 air 5 air 6 air 7 air 8 air 9 air 1 air 11 air 12 air 13 air 14 air 15 air 16 air 17 air 18 air 19 air 2 air 21 air 22 air 23 air 24 air 25 Loss (d) rosstalk 3 khz -1 MHz air 1 / air 2 air 1 / air 3 air 1 / air 4 air 1 / air 5 air 1 / air 6 air 1 / air 7 air 1 / air 8 air 1 / air 9 air 1 / air 1 air 1 / air 11 air 1 / air 12 air 1 / air 13 air 1 / air 14 air 1 / air 15 air 1 / air 16 air 1 / air 17 air 1 / air 18 air 1 / air 19 air 1 / air 2 air 1 / air 21 air 1 / air 22 air 1 / air 23 air 1 / air 24 air 1 / air 25 7
8 Specifications 12 / 218 Loss (d) Shielded, 25 air able MEHNIL onductors Type: Insulation: Shield: Drain: Jacket Outer Diameter: FLMMILITY: ELETIL Dielectric Withstanding Voltage: urrent ating: Voltage ating: ENVIONMENTL Operating Temperature: Moisture esistance: 24 WG (.5 mm) Solid tinned copper V,.32" thickness luminum polyester with 25% minimum overlap..1" thickness One 24 WG (.5 mm), solid tinned copper V,.22" thickness.33" able meets the requirements of Underwriters Laboratories, Standard 1581, vertical tray flame test (M ating). 5 Vrms per MIL-STD-22, method mps per conductor 3 Volts º to 4º 95% per MIL-STD-22, Method 16 Note: These are representative specifications for shielded, 25 pair ategory 2 cable. omplete specifications for all products are available upon request eturn Loss 3 khz -1 MHz Shielded, 25 air able with onnector air 1 air 2 air 3 air 4 air 5 air 6 air 7 air 8 air 9 air 1 air 11 air 12 air 13 air 14 air 15 air 16 air 17 air 18 air 19 air 2 air 21 air 22 air 23 air 24 air 25 Loss (d) rosstalk 3 khz - 1 MHz air 1 / air 2 air 1 / air 3 air 1 / air 4 air 1 / air 5 air 1 / air 6 air 1 / air 7 air 1 / air 8 air 1 / air 9 air 1 / air 1 air 1 / air 11 air 1 / air 12 air 1 / air 13 air 1 / air 14 air 1 / air 15 air 1 / air 16 air 1 / air 17 air 1 / air 18 air 1 / air 19 air 1 / air 2 air 1 / air 21 air 1 / air 22 air 1 / air 23 air 1 / air 24 air 1 / air 25 8
9 Specifications 12 / 218 Loss (d) Unshielded, 32 air able MEHNIL onductors Type: Insulation: Jacket Outer diameter: FLMMILITY: ELETIL Dielectric Withstanding Voltage: urrent ating: Voltage ating: ENVIONMENTL Operating Temperature: Moisture esistance: 24 WG (.5 mm) Solid tinned copper V,.6" thickness V,.35" thickness.43" able meets the requirements of Underwriters Laboratories, Standard 1581, vertical tray flame test (M ating). 75 Vrms per MIL-STD-22, method mps per conductor 15 Volts -3º to +6º 95% per MIL-STD-22, Method 16 Note: These are representative specifications for unshielded, 32 pair ategory 2 cable. omplete specifications for all products are available upon request. eturn Loss 3 khz - 1 MHz air 1 air Unshielded, 32 air able with onnector air 3 air 4 air 5 air 6 air 7 air 8 air 9 air 1 air 11 air 12 air 13 air 14 air 15 air 16 air 17 air 18 air 19 air 2 air 21 air 22 air 23 air 24 air rosstalk 3 khz - 1 MHz air 1 / air 2 air 1 / air 3 air 1 / air 4 air 1 / air 5 air 1 / air 6 air 1 / air 7 air 1 / air 8 air 1 / air 9 air 1 / air 1 air 1 / air 11 air 1 / air 12 air 1 / air 13 air 1 / air 14 air 1 / air 15 air 1 / air 16 air 1 / air 17 air 1 / air 18 air 1 / air 19 air 1 / air 2 air 1 / air 21 air 1 / air 22 air 1 / air 23 air 1 / air 24 air 1 / air 25 9
10 Specifications 12 / 218 Loss (d) Shielded, 32 air able MEHNIL onductors Type: Insulation: Shield: Drain: Jacket Outer diameter: FLMMILITY: ELETIL Dielectric Withstanding Voltage: urrent ating: Voltage ating: ENVIONMENTL Operating Temperature: Moisture esistance: 24 WG (.5 mm) Solid tinned copper V,.6" thickness luminum polyester with 25% minimum overlap..1" thickness One 24 WG (.5 mm), solid tinned copper V,.35" thickness.4" able meets the requirements of Underwriters Laboratories, Standard 1581, vertical tray flame test (M ating). 25 Vrms per MIL-STD-22, method mps per conductor 3 Volts º to 6º 95% per MIL-STD-22, Method 16 Note: These are representative specifications for unshielded, 32 pair ategory 2 cable. omplete specifications for all products are available upon request eturn Loss 3 khz - 1 MHz Shielded, 32 air able with onnector air 1 air 2 air 3 air 4 air 5 air 6 air 7 air 8 air 9 air 1 air 11 air 12 air 13 air 14 air 15 air 16 air 17 air 18 air 19 air 2 air 21 air 22 air 23 air 24 air 25 Loss (d) rosstalk 3 khz -1 MHz air 1 / air 2 air 1 / air 3 air 1 / air 4 air 1 / air 5 air 1 / air 6 air 1 / air 7 air 1 / air 8 air 1 / air 9 air 1 / air 1 air 1 / air 11 air 1 / air 12 air 1 / air 13 air 1 / air 14 air 1 / air 15 air 1 / air 16 air 1 / air 17 air 1 / air 18 air 1 / air 19 air 1 / air 2 air 1 / air 21 air 1 / air 22 air 1 / air 23 air 1 / air 24 air 1 / air 25 1
11 Specifications 12 / 218 Loss (d) Shielded lenum, 32 air able MEHNIL onductors Type: Insulation: Shield: Drain: Jacket: Outer diameter: FLMMILITY: ELETIL Dielectric Withstanding Voltage: urrent ating: Voltage ating: ENVIONMENTL Operating Temperature: Moisture esistance: 24 WG (.5 mm) Solid tinned copper Low smoke V,.6" thickness Overall aluminum foil/mylar providing full coverage One 24 WG (.5 mm), solid tinned copper Low smoke V,.16" thickness.362" able meets the requirements of Underwriters Laboratories, Standard 1581, vertical tray flame test (M ating). 25 Vrms per MIL-STD-22, method mps per conductor 3 Volts º to 6º 95% per MIL-STD-22, Method 16 Note: These are representative specifications for shielded, 32 pair ategory 2 cable. omplete specifications for all products are available upon request eturn Loss 3 khz - 1 MHz Shielded lenum, 32 air able with onnector air 1 air 2 air 3 air 4 air 5 air 6 air 7 air 8 air 9 air 1 air 11 air 12 air 13 air 14 air 15 air 16 air 17 air 18 air 19 air 2 air 21 air 22 air 23 air 24 air 25 Loss (d) rosstalk 3 khz - 1 MHz air 1 / air 2 air 1 / air 3 air 1 / air 4 air 1 / air 5 air 1 / air 6 air 1 / air 7 air 1 / air 8 air 1 / air 9 air 1 / air 1 air 1 / air 11 air 1 / air 12 air 1 / air 13 air 1 / air 14 air 1 / air 15 air 1 / air 16 air 1 / air 17 air 1 / air 18 air 1 / air 19 air 1 / air 2 air 1 / air 21 air 1 / air 22 air 1 / air 23 air 1 / air 24 air 1 / air 25 11
12 Web Site: From North merica, all Toll Free: Outside of North merica: Fax: For a complete listing of D's global sales office locations, please refer to our web site. D Telecommunications, Inc.,.O. ox 111, Minneapolis, Minnesota US Specifications published here are current as of the date of publication of this document. ecause we are continuously improving our products, D reserves the right to change specifications without prior notice. t any time, you may verify product specifications by contacting our headquarters office in Minneapolis. D Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. roducts or features contained herein may be covered by one or more U.S. or foreign patents / Original 2 D Telecommunications, Inc. ll ights eserved n Equal Opportunity Employer
SPEC SHEET. OmniReach FTTX Solutions. NEMA Fiber Demarcation Box (FDB) Features
ADC s OmniReach FTTX Solutions are the industry s first infrastructure solutions designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability,
More informationComtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant
Comtran Cable Commercial Premise & Specialty Datacom Products Cat 5e - Cat 6A LSZH & Industrial Ethernet Indoor/Outdoor & Outside Plant Category 6 Commercial Premise Plenum: UL Type CMP Riser: UL Type
More informationCABLED TWISTED PAIRS CONDUCTORS
CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete
More informationµcom-10gb + Harsh Environment 10Gb Ethernet Micro Connectors
Harsh Environment 10Gb Ethernet Micro onnectors 15mm Description µom-series is a new range of connectors designed to address the latest trends of the industry : miniaturization and high speed, with the
More informationCABLED SINGLE CONDUCTORS
CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of
More information6LGH High Voltage Connectors
LGH High Voltage onnectors 6-Pin, Subminiature Rectangular onnectors Product acts xtremely lightweight total weight of mated pair is less than 14 grams ompact design requires less than.6 square inch [387
More informationDATA-CON-X : SEALED USB TYPE A & B CONNECTORS
FEATURES & BENEFITS Sealed to IP67 & IP68 NEMA 250 (6P) (when mated) Feed-thru termination on the panel for easy field installation Field installable design is easy to assemble Quick connect bayonet or
More informationINSTRUMENTATION CABLE
APPLICATION Used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields. Design
More informationOrdering Information
Ordering Information STUBS P/N ONE P/N TWO CONNECTOR and REFERENCE TERMINATION TERMINATIONS MATING CONNECTOR FIGURE 2 ESI-2210 ESI-2310 BJ770/PL75 1/2 2 ESI-2220 ESI-2320 BJ377/PL375 1/2 2 ESI-2230 ESI-2330
More informationSPECIFICATIONS for INTERNALLY TERMINATED COUPLERS
3.575 Bus-J1 ESI-2210 1 Stub-J2 Stub-J3.90.166 +.003 Dia. 3 X.487 Ref. 2.75 figure 1 J1 (BUS) J2 (STUB) J3 (STUB) - = 59 Ohms, 1%, 2W = 78 Ohms, 1%, 2W - = TURNS RATIO 1 : 1.41 TWO STUB ONE INTERNAL TERMINATION
More informationSecurity Coaxial Cable
N E W G E N E R A T I O N C A B L E S 20.37 Security ial Cable Surveillance CCTV ed or Flooded for Use in Underground Ducts CM FT1 Rated Bare copper conductor, foam polyethylene insulation, bare copper
More informationSHIELD-FLEX EMI / RFI Shielded Conduit
Type SLA SHIELD-FLEX EMI / RFI Shielded Conduit Type EMS Type EMCS z Wire without interference. Shielded conduit provides exceptional shielding effectiveness from electromagnetic and radio frequency interference
More informationMedium Voltage Cables for PermaLife Nuclear Utility Applications
Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with
More information17 TW SERIES. Hybrid Connector SPECIFICATIONS: MATERIALS AND PLATINGS ELECTRICAL DATA CLIMATIC DATA MECHANICAL DATA
17 TW SERIES Hybrid onnector mphenol s 17TW series hybrid -Subminiature connectors are available with power, coax, high voltage and signal contacts assembled in the same connector body. These connectors
More informationFISCHER FREEDOM TM SERIES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More informationConnectors Conforming to European Safety Standards
Series RoS ompliant onnectors onforming to European Safety Standards s of January 1995 all industrial machinery, including machine tools, which are exported to Europe must conform with European safety
More informationGeneral Specifcations
General Specifcations GS 11M12WZ-01-E Specifcations for model WZ Heater and Signal Cables for Oxygen Detectors The WZ-H cables supplied by Yokogawa Corporation of merica (YC) are compatible with all Yokogawa
More informationDetailed Specifications & Technical Data
Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical
More information*HDMI-STYLE WEATHERTIGHT CONNECTORS *HDMI-STYLE WEATHERTIGHT CONNECTORS NPB C714
601 E WILDWOOD VILLA PARK, IL 60181 P: 630.834.7504 F: 630.834.8540 WWW.CONXALL.COM FEATURES & BENEFITS Sealed to IP67 & IP68 NEMA 250 (6P) (when panel connector is rear mounted and mated to the cable)
More informationEMSA X - XX - SZ - CXX
date 08/21/2012 page 1 of 5 SERIES: EMS 6W DESRIPTION: -D POWER SUPPLY FETURES up to 6 W power interchangeable blades universal input (90~264 Vac) single regulated from 5~15 V over voltage and short circuit
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18
Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationK CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More information4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60
4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)
More informationRE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable
RE-T2X(st)H SWAH - BS EN 50288-7 Mica XLPE / LSZH / CAM / SWA / LSZH Cable Eland Product Group: I APPLICATION These cables are designed to connect electrical instrument circuits and provide counication
More information1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps
s easy as 1,2,3... Mark 10 Powerline immable allasts Listed 704G Philips dvance Mark 10 Powerline immable allasts make converting your existing fixtures easy. For companies looking to make their fixed-output
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationINTRODUCTION. Products CONTENTS. Circular Threaded Coupling Connectors. Reverse Bayonet Coupling Connectors
IOUIO etronics India, established as manufacturers of connectors in, has grown into a leading producer and exporter of I grade electrical connectors and related accessories. etronics India's continuing
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100
More informationAurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14
Zone Sensors Submittal Data English Language/IP Units SD1582EW 10/14 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and
More informationSHIELD-FLEX EMI / RFI Shielded Conduit
Type SLA SHIELD-FLEX EMI / RFI Shielded Conduit Type EMS EMCS Type z Wire without interference. Shielded conduit provides exceptional shielding effectiveness from electromagnetic and radio frequency interference
More informationPOLYCAB WIRES PVT. LTD.
Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored Variable Frequency
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color
More informationLDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.
INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded
More informationEthernet Buccaneer BUCCANEER DATA. bulgin
BUCCANEER FOR DATA bulgin Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains
More informationEdison single-phase capacitor switch
Power apacitors atalog Data 232EN Supersedes October 26 OOPER POWER SERIES Description Eaton delivers economical, reliable, and flexible solutions for demanding capacitor switching application needs with
More informationNMJ Series 5.2kVDC Isolated 1W DC-DC Converters
www.murata-ps.com NMJ Series FEATURES UL60950 recognised Wide temperature performance at full 1 watt load, 40 to 85 Single and dual outputs SIP package style 5.2kVD isolation Hi Pot Test 3V, 5V & 12V input
More informationMICRODOT Microminiature D Connectors. MICRODOT Microminiature D Connectors Introduction
MIRODOT Microminiature D onnectors Introduction Product Facts Designed for both military and commercial applications Low engaging force is achieved by the manner in which Twist ontacts are designed The
More informationType P Drilmar 125-XE Signal & Instrumentation
Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,
More informationEthernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA
IP68 Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains IP68 seal to panel
More informationSolid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816
Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation
More informationManufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation
More informationMCON INTERCONNECTION SYSTEM
MON INTERONNETION SYSTEM for the utomotive Industry TE UTOMOTIVE /// MON Interconnection System INNOVTIVE TEHNOLOGIES TE onnectivity (TE) is a leader in automotive connectivity and sensor technology. Our
More informationPOLYCAB WIRES PVT. LTD.
Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationType P Drilmar 125-XE Signal & Instrumentation
Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,
More informationData sheet Patch cord Cat.6 A AWG m gray
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch
More informationINTRODUCTION. Products CONTENTS. Circular Threaded Coupling Connectors. Reverse Bayonet Coupling Connectors
OUO etronics ndia, established as manufacturers of connectors in, has grown into a leading producer and exporter of grade electrical connectors and related accessories. etronics ndia's continuing mission
More informationAmerican Standard ProAx Triaxial Camera Connectors Installation Instructions
American Standard ProAx Triaxial Camera Connectors Installation Instructions Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 : 18 AWG stranded bare copper conductors, PP insulation, PVC jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color coded by
More informationMIL-PRF QPL Connectors MIL-PRF QPL Adapters Online Catalog Volume 1
MIL-PRF-39012 QPL onnectors MIL-PRF-55339 QPL dapters Online atalog Volume 1 Delta QPL connectors and adapters meet or exceed all requirements of MIL-PRF-39012 and MIL-PRF-55339. ecause these specifications
More informationUNSHIELDED MULTI CONDUCTOR
PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,
More information2mm Pitch, Positive Lock, Wire-to-Board Connector (UL, C-UL Listed)
2mm Pitch, Positive Lock, Wire-to-oard onnector (UL, -UL Listed) DF51 Series Secure Mating Lock Insertion force curb Jan.1.2019 opyright 2019 HIROSE ELETRI O., LTD. ll Rights Reserved. Features 1. Positive
More informationCoupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut
Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68
More informationTHE RIGHT SOLUTION FOR EVERY APPLICATION
VFD ABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLIATION Products Added VFD Lean TR VFD Dual TR Servo VFD ombo DS VFD XLPE TR VFD XLPE 2KV TR Also Included! FLEXIBLE ONTROL ONTINUOUS FLEX SILIONE
More informationNew Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications
New Product Bulletin NP 307 PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications NFPA-79-2002 Standard Compliance Eliminates the need for Conduit or
More informationVITALink Taped Splice Pigtail Crimp
A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice
More informationEthernet 100 Mbps Quadrax
Ethernet 100 Mbps Quadrax Quadrax Contact Today s technology for Airbone and Military equipment is more and more complex, requiring the management of an increasing flow of information at greater speeds.
More informationAMPLIMITE Cable Connector Accessories
MPLIMITE Cable Connector ccessories Quick Reference Guide We offer one of the broadest, most versatile portfolios of Dsubminiature connectors in the market with unrivaled engineering support to address
More informationInterconnect Cable Simplex and Duplex
10.3 Interconnect Cable Simplex and Duplex Tight Buffer & Plenum Rated Patch panels Workstation equipment connections Horizontal distribution in open office environments Interconnect Cables are designed
More informationProduct Diversity Knowledge Transfer MPS Expertise Globalization Integrative Thinking Product Information System Enclosure Ripac Vario-Module
Product Diversity Knowledge Transfer MPS Expertise Globalization Integrative Thinking Product Information System Enclosure Ripac Vario-Module May be used as an instrument case or rack-mounted enclosure
More informationPCB Single Row Connectors
SERIES PB Single Row onnectors Vertical Surface Mount PB onnectors with Jackscrews How to Order Vertical Surface Mount PB onnectors feature gold alloy TwistPin contacts. These nanomimiature connectors
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Connectors Features Snap-on interface facilitates assembly Conforms to CECC
More informationData sheet Patch cord Cat.6 A AWG m black
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch
More informationMS/Standard DL-Class Pre-Earth type
MS/Standard L-lass Pre-arth type mphenol R mphenol ML--5015 onnectors L Series Pre-earth type L Series are highly reliable circular connectors (wire soldering type) approved by TUV satisfying uropean safety
More informationSeries 80 Mighty Mouse Technical Reference Complete Product Specification
80 Mighty Mouse Technical Reference Reference SRIPTION RQUIRMNT PROUR TRI ontact resistance S S39029 Table V Max Wire Test Voltage Size urrent rop 12 23 42 14 17 40 16 13 49 20 7.5 55 22 5 73 24 3 45 26
More informationPERFORMANCE SPECIFICATION SHEET ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY. (BETWEEN SERIES BNC TO SERIES TNC), CLASS 2, STRAIGHT PLUG
INCH-POUND MIL-PRF-55339/38A 10 January 2005 SUPERSEDING MIL-PRF-55339/38 11 January 1977 PERFORMANCE SPECIFICATION SHEET ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY. (BETWEEN SERIES BNC TO SERIES TNC),
More informationAmphenol 348 Series High Density Connectors
348 Series High Density Connectors 12-093-6 348 Series I, II Table of Contents 348 Series Page No. High Density Connectors........................................................................ 1 Specifications.................................................................................
More information6000 Series Ethernet Buccaneer
Thermo-plastic version Patch Cord Flex Connector - Pur Jacket Cable PXP6037 Mates with PXP6033TP type panel mounting Overmoulded patchcords with IP rated connector Supplied with shielded RJ45 plug Single
More informationPreparing the Site. Information About the Site Requirements CHAPTER
2 CHAPTER This chapter describes the basic site requirements that you should be aware of as you prepare to install your Cisco Nexus 7000 Series switches. This chapter includes the following sections: Information
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationCorflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3
Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation
More informationXTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET
XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET UL TYPE PLTC UL AWM STYLE 20237 CSA AWM IA/B IIA/B FT1 76 CHOOSE XTRA GUARD 4 FOR: Three Times the Low-Temperature
More informationTOF Low Voltage System Review. October 6, 2006 V. Ghazikhanian 1
TOF Low Voltage System Review 1 TOF Low Voltage Power System. The TOF low voltage system is based on the Wiener PL512 low noise, high efficiency switching power supply mainframe. These units are the upgraded
More informationA. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.
SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems
More informationDEUTSCH 9316 SERIES FOR MARINE AND OFFSHORE APPLICATIONS
DUTH 936 I FO MIN ND OFFHO ITION Harsh nvironment, Flameproof onnectors for ugged eliability and afety MIN OI ND G /// 936 I ONTNT Introduction/pecifications 3 ynopsis / ing ystem 4-5 ontact rrangements
More informationFAZ CONNECTOR. 1Certified LR Connectors for FFC. Features. Specifications. Standards. 1.0mm
mm pitch FZ ONNETOR onnectors for FF Emboss Tape Features Zero insertion force mechanism (ZIF) ZIF mechanism improves wear resistance and extends the mating life of the connector. y moving the slider into
More information1 GENERAL INFORMATION
Broadcast and Entertainment Products ProAx Triaxial Camera Connectors Installation Instructions Content Page 1 GENERAL INFORMATION... 2 1.1 Standard Tools... 3 1.2 ADC ProAx Triaxial Cable Strip Gauge...
More informationApplication Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D
Application Specification Circular Plastic Connector (CPC) 114-13137 Series 45 System 05 AUG 14 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions
More informationfor Quadrax and ELIO 8
1 - CHARACTERISTICS Mechanical Current ratings, continuous: Endurance: 500 matings Insertion and extraction forces, max: - shell size 1: 120 N (27 Ibs) - shell size 2: 267 N (60 Ibs) - shell size 3: 467
More information- - Introduction. Specifications
14 SERIES Introduction Amphenol 14 series connectors are water resistant, polarised, five and six contact electrical connectors for use in low voltage audio frequency circuits and applications. They employ
More informationSMA Male Connector Solder Attachment for RG188-DS, RG316-DS
SMA Male Connector Solder Attachment for RG188-DS, RG316-DS RF Connectors Technical Data Sheet PE4402 Configuration SMA Male Connector MIL-STD-348A 50 Ohms Straight Body Geometry Features Max Operating
More informationElectrical Voltage rating Test Voltage (Vrms) service rating sea level at 21000m M N I II
JVS ronze Series pplications Navy vessels - Military - Merchant fleet - Transportation - Oceanography - attle-field cables, shelters - Signalling - ield equipments Standards MIL- 38999 Series III 75 201.002
More informationKDB / VG Series
/ V 9523 Series ontents Introduction........................... 2 onnector design...................... 2 Technical data......................... 3 ounting dimensions.................. 5 ow to order..........................
More informationOkoguard -Okoseal Type IEC
COMPACT STRAND CONSTRUCTION A B C D E F G H Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded Semiconducting EPR Phase
More informationAutomatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit
Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.
More informationType MMV-WP Medium Voltage Wind Power Cable
WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation
More informationPow-R-Flex low ampere busway
Pow-R-Flex low ampere busway Commercial Industrial Telecommunications Data centers Research Light manufacturing Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway provides
More informationEasier! Faster! Safer!
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...
More informationCONTENTS 1. Introduction.1 2. Features Panel 3 4. Fail indicators.4 5. Operation 8 6. Battery replacement.12 7.
CONTENTS 1. Introduction.1 2. Features..1 3. Panel 3 4. Fail indicators.4 5. Operation 8 6. Battery replacement.12 7. Specifications 14 1. Introduction The network cable tester is a small hand-held cable
More informationM Ball Valve Linkage Kit
Product ulletin M9000-520 Issue Date May 1, 2005 M9000-520 all Valve Linkage Kit The M9000-520 all Valve Linkage Kit is designed specifically for field mounting Johnson ontrols M9106 and M9109 Series Non-Spring
More informationFILTER D-SUB. connectors
FILTER -SUB connectors table of contents MIL-TL-24308...3 Layouts...3 -Subminiature onnectors...4 How to order...5 MIL-TL-83513...6 onnectors and Layouts...7 How to order...8 OMBO -SUB MINITURE... 9 High
More informationMicro-D TwistPin Connectors and Accessories Product Selection Guide
Micro-D TwistPin onnectors and ccessories Product Selection Guide MIL-DTL-833 onnectors Section Glenair OTS Micro-D onnectors Section Micro-D Printed ircuit oard onnectors Section Micro-D ackshells and
More informationGenerator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit
Instruction Sheet 10 2004 Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit 541 0810 GENERAL INFORMATION This kit contains one Control Communications Module (CCM-G) with
More informationZHPCG CK0226 POWER CABLE WIRE & CABLE
ZHPCG CK0226 POWER CABLE WIRE & CABLE ZHPCG CK0226 POWER CABLE WIRE & CABLE Application/Use Rail approved zero Halogen Power Cables, available as 750V or 1800V rated. ZHPCG cables are all Halogen free,
More informationSeries 80 Mighty Mouse Technical Reference Complete Product Specification
Summary Performance Specifications Current Rating (Maximum): Size #23 Contact: 5 A., Size #20 contact: 7.5 A., Size #16 contact: 13 A., Size #12 contact: 23 A. Test Voltage (Dielectric Withstanding Voltage)
More informationπ network filter insertion loss - attenuation (db)
MI/RFI Applications All electronics equipments Standards oncerned equipments : F, V, MIL-ST 461, GAMG 13 Typical performance capacitive filter π network filter escription Filter connectors have been developed
More informationVolition. Fiber Optic Cable. 3Innovation
Volition Fiber Optic Cable Tough enough to take it. Easy to handle. Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm
More informationFAKRA Jack Right Angle Connector Crimp/Solder Attachment for RG174, RG316, RG188,.100 inch, PE-B100, PE-C100, LMR-100, White Color
FAKRA Jack Right Angle Connector Crimp/Solder Attachment for RG174, RG316, RG188, 100 inch, PE-B100, PE-C100, LMR-100, White Color PE44648B Configuration FAKRA Jack Connector 50 Ohms Right Angle Body Geometry
More informationF-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:
-0 Motor ircuit Protectors Vol. 1, Ref. No. [058] -rame Table -188. V A, V NMA Starter Size ont. Amps am Motor ull Load urrent Amps MP Trip MP Table -188. V A, V (ontinued) NMA Starter Size ont. Amps am
More information