American Standard ProAx Triaxial Camera Connectors Installation Instructions

Size: px
Start display at page:

Download "American Standard ProAx Triaxial Camera Connectors Installation Instructions"

Transcription

1 American Standard ProAx Triaxial Camera Connectors Installation Instructions Content Page INTRODUCTION Revision History Trademark Information Admonishments GENERAL INFORMATION Standard Tools ADC ProAx Triaxial Cable Strip Gauge ProAx Triaxial Connector Components ASSEMBLY PROCEDURE FOR PROAX TRIAXIAL CONNECTOR JACK AND PLUG CUSTOMER INFORMATION AND ASSISTANCE INTRODUCTION This manual provides procedures for installing ADC s ProAx Triaxial Camera Connectors on triaxial inch diameter cables. Because assembly of ProAx triaxial connectors differ from the assembly of other triaxial connectors, it is very important that this procedure be closely followed. Revision History ISSUE DATE REASON FOR CHANGE 1 01/2000 Original 2 07/2004 Add dual dimensions and remove Global references. Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc., ProAx is a trademark of ADC Telecommunications, Inc., Fischer is a registered trademark of Fischer Connectors, Inc., LEMO is a registered trademark of LEMO SA Rev A Page 1

2 Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. 1 GENERAL INFORMATION ADC ProAx Triaxial Camera Connectors may be used to mate any two triax cables together, cables need not be from the same manufacturer. Once a cable is terminated with a back shell it can easily be converted to mate with any other triax connector standard by adding the appropriate front center conductor shell assembly, outer insulator, and front connector body. ADC offers connector components (front center conductor shell assembly, outer insulator, and front connector body) to match most standard connectors in the industry (Kings, Fischer, Lemo, etc.). Use this procedure to ensure the correct assembly and reliable operation of ProAx triaxial connectors. This connector assembly procedure is intended to be used for assembling all sizes of female ProAx triaxial jacks and all sizes of male ProAx triaxial plugs. Note: Because assembly of ProAx triaxial connectors is different than the assembly of other manufacturers triaxial connectors, please follow this assembly procedure closely. 1.1 Standard Tools ProAx triaxial connectors are assembled using standard (inch measurement), common tools. A measuring tape or ruler and pen or marker are used to measure and mark the amount of cable jacket, dielectric, and braid to cut. Tape, such as plastic electrical tape or masking tape is also used to hold the outer braid in place during the assembly procedure. Required tools are shown in Figure 1. Page 2

3 TWO 7/16-INCH OPEN END OR COMBINATION WRENCHES TWO 7/8-INCH OPEN END OR COMBINATION WRENCHES VOLT/OHM METER KNIFE OR BLADE IN HOLDER CRIMP TOOL WITH APPROPRIATE DIE SET SIDE CUTTERS A Figure 1. Standard Tools Used for ProAx Triaxial Connector Assembly 1.2 ADC ProAx Triaxial Cable Strip Gauge An optional ADC ProAx triaxial cable strip gauge may be used to measure and hold the cable when cutting cable jacket, dielectric, and braid. An optional ADC ProAx triaxial cable strip gauge is shown in Figure 2. To use the optional ADC ProAx triaxial cable strip gauge in this connector assembly procedure, insert cable into slot in gauge corresponding to the operation to be performed. Insert cable into the end of the slot against the wall in the slot. Then cut the cable jacket, dielectric, or braid at the edge of the gauge, parallel to gauge edge, all around the cable in the order noted. Page 3

4 ProAx CUT JACKET CUT DIELECTRIC CUT INNER BRAID CUT INNER DIELECTRIC A Figure 2. ADC ProAx Triaxial Cable Strip Gauge 1.3 ProAx Triaxial Connector Components Each ProAx triaxial connector consists of the individual parts shown in Figure 3. Also shipped with the ProAx triaxial connector is an installation drawing. For additional information refer to installation drawing when assembling the connector. Some parts are partially assembled or are placed within other parts for shipping. Before beginning assembly of ProAx triaxial connector, remove all parts from shipping bags and separate all parts. Unscrew rear end cap from front connector body and remove ground washer and outer conductor insulator from inside of the front connector body. Remove O-ring and rear seal ring from inside the rear end cap. Page 4

5 (SHIPPED INSIDE ) SPLIT, TAPERED END SEAL RING (SHIPPED INSIDE ) INSERT WITH TWO S GROUND WASHER (SHIPPED INSIDE FRONT CONNECTOR BODY) END SPACER (SHIPPED INSIDE CONDUCTOR INSULATOR) * CENTER CONDUCTOR SHELL *CENTER CONDUCTOR PIN (MALE) *CRIMP SLEEVE *FRONT CENTER CONDUCTOR SHELL ASSEMBLY CONDUCTOR INSULATOR (SHIPPED INSIDE FRONT CONNECTOR BODY) FRONT CONNECTOR BODY *NOTE: THESE PARTS SHIPPED IN SMALL BAG F Figure 3. ProAx Triaxial Connector Components, Male Connector Components Shown Page 5

6 2 ASSEMBLY PROCEDURE FOR ProAx TRIAXIAL CONNECTOR JACK AND PLUG Assemble ProAx triaxial connector on the corresponding size of triaxial cable by performing the following steps: 1. Using a blade (blade in holder or knife), cut the end of cable off as square to the cable as possible. See Figure Slide rear end cap onto the cable. Slide O-ring onto the cable. Slide rear seal ring over the outer jacket of cable with the larger inner diameter (thinner ring wall) facing towards the cut end of the cable. See Figure 3 and Figure 4. LARGER INNER DIAMETER SEAL RING CUT END SQUARE A JACKET Figure 4. Rear Seal Ring, O-Ring, and Rear End Cap on Cable 3. Using a blade, cut a inch (2.62 cm) length of outer jacket from the cable (see dimensions in Figure 5). Cut off outer jacket only, evenly around entire cable. If using the ADC triaxial cable strip gauge, place end of cable into slot labeled, CUT JACKET. Push the end of cable against the end of the slot. Cut outer jacket only, evenly around entire cable, at the edge of the gauge (parallel to the gauge edge). Note: Be careful to not cut deeper than the outer jackets so that the outer braid is not cut or nicked IN. (2.62 CM) BRAID LARGER INNER DIAMETER SEAL RING A CUT EVENLY AROUND ENTIRE JACKET Figure 5. Outer Jacket Cut Dimensions Page 6

7 4. After removing outer jacket, wrap tape around outer braid (shield) to prevent braid from fraying and breaking. See Figure 6. TAPE END BRAID LARGER INNER DIAMETER SEAL RING A JACKET Figure 6. Tape Braid to Prevent Fraying and Breaking 5. Slide threaded insert (see Figure 3) over the tape and outer braid. Push the end of threaded insert against outer dielectric (inner jacket and insulation) until it is seated. See Figure 7. Note: Do not tighten any parts that are on the cable together at this time. This will be done later in this procedure. TAPERED SPLIT END OF INSERT DIELECTRIC (INNER JACKET) BRAID SEAL RING TAPE INSERT A Figure 7. Threaded Insert Installation 6. Remove tape from the end of the cable. Pull back outer braid and comb it out over the threaded insert (see Figure 8). Page 7

8 DIELECTRIC (INNER JACKET) TAPERED SPLIT END OF INSERT BRAID (TRIMMED) SEAL RING INSERT A Figure 8. Outer Braid Trimmed 7. Using a side cutters, trim excess braid so that braid extends just beyond the lip (raised edge next to O-ring) of the threaded insert. See Figure 8 and Figure 9. (SHIPPED INSIDE ) SEAL RING (SHIPPED INSIDE ) INSERT RAISED EDGE GROUND WASHER (SHIPPED INSIDE FRONT CONNECTOR BODY) DIELECTRIC SPLIT END OF INSERT BRAID (TRIMMED) A Figure 9. Cable with Outer Braid Over Threaded Insert, After Trimming 8. Slide ground washer (see Figure 3) over cable and push it against the trimmed braid and over threaded insert (pushing the braid over the threaded insert). See Figure Using a blade, remove outer dielectric (inner jacket and insulation) so that the length from the end of the cable to the end of the outer dielectric is 0.59-inch (1.51 cm). See dimensions in Figure 10. Cut outer dielectric only, evenly around entire cable. If using the ADC ProAx triaxial cable gauge, place end of cable into slot labeled, CUT DIELECTRIC. Push end of cable against the end of the slot. Cut outer dielectric only, evenly around entire cable, at the edge of the gauge. Page 8

9 Note: Be careful to not cut or nick the inner braid IN. (1.51 CM) DIELECTRIC (INNER JACKET) TAPERED SPLIT END OF INSERT 0.31 IN. (0.79 CM) 0.13 IN. (0.32 CM) GROUND WASHER SEAL RING INNER BRAID INNER DIELECTRIC CENTER CONDUCTOR INSERT A Figure 10. Inner Braid, and Inner Dielectric Cut Dimensions 10. Using a blade, remove inner braid so that the length from the end of cable to the end of the inner braid is 0.31-inch (0.79 cm). See dimensions in Figure 10. Cut inner braid only, evenly around entire cable. If using the ADC ProAx triaxial cable gauge, place end of cable into slot labeled, CUT INNER BRAID. Push end of cable against the end of the slot. Cut inner braid only, evenly around entire cable, at the edge of the gauge. Note: Be careful to not cut or nick inner dielectric under the braid. 11. Using a blade, remove inner dielectric so that the length from the end of the cable to the end of the inner dielectric is 0.13-inch (0.32 cm). See dimensions in Figure 10. Evenly cut inner dielectric only, around entire cable. If using the ADC triaxial cable gauge, place end of cable into slot labeled, CUT INNER DIELECTRIC. Push end of cable against the end of the slot. Evenly cut inner dielectric only, around entire cable, at the edge of the gauge. Note: Be careful to not cut or nick center conductor under the inner dielectric. 12. Slide a center conductor pin (see Figure 3) over the center conductor of the cable, against inner dielectric. See Figure 11. Note: Be sure that center conductor pin is fully seated against inner dielectric and that cable center conductor is visible through the inspection hole in the center pin (see Figure 11). Note: If using stranded center conductor cable make certain all of the strands are inserted inside the center conductor pin. Do not trim away any that are on the outside, if necessary twist the stranded conductor together before sliding it into the center conductor pin. Page 9

10 13. Using the in. (1.73 mm) center pin die in crimp tool, align and crimp center conductor pin onto the cable center conductor. One side of for right handed people the other side is for left handed people. This connection may also be made using solder. 14. Slide a crimp sleeve (see Figure 3) over inner braid and outer dielectric, up against the ground washer. See Figure Loosen and spread out inner braid. 16. Slide the split, tapered end of rear center conductor shell inside the crimp sleeve (pushing inner braid inward between rear center conductor shell and crimp sleeve), twisting the rear center conductor shell as it is inserted. Ensure that inner braid is evenly distributed between rear center conductor shell and crimp sleeve, and that crimp sleeve is against the raised center section of the rear conductor shell. FRONT CENTER CONDUCTOR SHELL INSIDE FEMALE PIN CENTER CONDUCTOR SHELL INSPECTION HOLE DIELECTRIC (INNER JACKET) GROUND WASHER OVER BRAID END CENTER SECTION SPLIT, TAPERED END CRIMP SLEEVE INNER BRAID MALE CENTER CONDUCTOR PIN CRIMPED ON CENTER CONDUCTOR INSERT C Figure 11. Ground Washer Over Outer Braid, Center Conductor Pin Crimped on Cable Center Conductor Adjust the position of rear center conductor shell and crimp sleeve on cable so that the center conductor pin is approximately flush with the threaded end of the rear center conductor shell and is centered in conductor shell. See Figure 12. Verify that outer dielectric is visible between crimp sleeve and ground washer (see Figure 11 and Figure 12). 17. Using a larger die in crimp tool, crimp around the crimp sleeve. See Figure Screw front center conductor shell into rear center conductor shell. Ensure that male center conductor pin and female pin in front center conductor shell fit together correctly. See Figure Using two 7/16-inch open end wrenches, tighten front and rear center conductor shell assembly. Hold rear shell stationary and turn front shell. Page 10

11 Note: Be sure that center conductor pin is centered in rear center conductor shell assembly. INSERT DIELECTRIC VISIBLE CRIMP SLEEVE (BEFORE CRIMPING) END GROUND WASHER OVER TRIMMED BRAID CENTER CONDUCTOR SHELL (SPLIT TAPERED END UNDER CRIMP SLEEVE) CENTER CONDUCTOR PIN CENTERED AND APPROX. FLUSH WITH END OF CENTER CONDUCTOR SHELL D Figure 12. Rear Center Conductor Shell and Crimp Sleeve Assembled with Outer Dielectric Visible CENTER CONDUCTOR SHELL CRIMP SLEEVE (AFTER CRIMPING) D Figure 13. Crimping the Crimp Sleeve on the Inner Braid Page 11

12 20. If the connector is used for 1/2-inch C (0.5-inch) cable, insert spacer (approximately 1/8- inch/3mm wide) over outer dielectric, between ground washer and crimp sleeve. For connectors used with other sizes of cable, insert spacer (approximately 1/2-inch/13 mm wide) over the crimp sleeve (after crimping), between ground washer and center conductor shell assembly. See Figure Slide outer conductor insulator (see Figure 3) over center conductor shell assembly. See Figure 14. Ensure that outer conductor insulator seats against ground washer. If necessary, move threaded insert and ground washer towards the outer conductor insulator. Observe that, in a female (receptacle) connector assembly, center conductor pin extends slightly beyond the end of outer conductor insulator, and in a male (plug) connector assembly, center conductor pin is flush with the end of the outer conductor insulator. If this is not observed, adjust position of outer conductor insulator by moving threaded insert and ground washer. Note: If necessary, trim excess outer braid that extends beyond outer diameter of ground washer as shown in Figure 14. *SPACER INSERTED AFTER CRIMPING FRONT CONNECTOR BODY CONDUCTOR INSULATOR CENTER CONDUCTOR SHELL ASSEMBLY CRIMPED SLEEVE DIELECTRIC INSERT BRAID (TRIMMED) GROUND WASHER SEAL RING *NOTE: SPACER (APPROXIMATELY 1/8 INCH WIDE, SHOWN), USED WITH CONNECTOR FOR 1/2-INCH "C", FITS OVER THE DIELECTRIC, BETWEEN GROUND WASHER AND CRIMP SLEEVE. SPACER (APPROXIMATELY 1/2 INCH WIDE, SHOWN IN FIGURE 3), USED WITH CONNECTORS FOR OTHER SIZE S, FITS OVER CRIMP SLEEVE (AFTER CRIMPING), BETWEEN GROUND WASHER AND CENTER CONDUCTOR SHELL E Figure 14. Connector Assembly, Showing Spacer and Outer Conductor Insulator Location Page 12

13 22. Slide front connector body over outer conductor insulator and ground washer, and screw onto threaded insert. Using two 7/8-inch open end wrenches, tighten front connector body and threaded insert. Hold rear assembly (threaded insert) stationary and turn front connector body. 23. Screw rear end cap with O-ring and rear seal ring over the threaded insert. 24. Using two 7/8-inch open end wrenches, tighten rear end cap and threaded insert. Hold middle assembly (threaded insert) stationary and turn rear end cap. Note: Tighten rear end cap until the two assemblies are fully seated together and no threads are visible. 25. Using an ohmmeter, measure between each braid and measure between each braid and the center conductor for infinite resistance, assuring no short circuits between any conductors. Measure end to end continuity (low resistance) on all three conductors. 26. Place dust cover attachment ring over the front connector body into one of the grooves (either side of the knurling) on front connector body. Page 13

14 3 CUSTOMER INFORMATION AND ASSISTANCE PHONE: EUROPE Sales Administration: Technical Assistance: EUROPEAN TOLL FREE NUMBERS Germany: UK: Spain: France: Italy: U.S.A. OR CANADA Sales: Extension Technical Assistance: Connectivity Extension Wireless Extension ASIA/PACIFIC Sales Administration: Technical Assistance: ELSEWHERE Sales Administration: Technical Assistance: WRITE: ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN , USA ADC TELECOMMUNICATIONS (S'PORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: L Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC's Technical Assistance Center. All Rights Reserved Printed in U.S.A Page 14

1 GENERAL INFORMATION

1 GENERAL INFORMATION Broadcast and Entertainment Products ProAx Triaxial Camera Connectors Installation Instructions Content Page 1 GENERAL INFORMATION... 2 1.1 Standard Tools... 3 1.2 ADC ProAx Triaxial Cable Strip Gauge...

More information

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions ADCP-92-129 Issue 1 6/2010 Content Page INTRODUCTION.............................................................................

More information

12-Inch Hybrid Fiber Access Terminal Installation Instructions

12-Inch Hybrid Fiber Access Terminal Installation Instructions 12-Inch Hybrid Fiber Access Terminal Installation Instructions 19683-A Content Page 1 PRODUCT DESCRIPTION.................................................................. 2 2 PRODUCT FUNCTION.....................................................................

More information

Fiber Splice Panel Rack Mount User Manual

Fiber Splice Panel Rack Mount User Manual Fiber Splice Panel Rack Mount User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Admonishments... 2 1. DESCRIPTION... 2 A. Product Definition

More information

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions DS Plug-In Digital Signal Cross-Connect (PIX-DSX-) 9-Inch Shelf Kit Installation Instructions Contents Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications...2

More information

PowerWorx DSX Series GMT Fuse Panel User Manual

PowerWorx DSX Series GMT Fuse Panel User Manual PowerWorx DSX Series GMT Fuse Panel User Manual ADCP-80-538 Issue 4 2/2012 1206873 Rev E Preface COPYRIGHT 2011, Tyco Electronics Corporation All Rights Reserved REVISION HISTORY ISSUE DATE REASON FOR

More information

FL2000 Termination/Splice Panels User Manual

FL2000 Termination/Splice Panels User Manual FL2000 Termination/Splice Panels User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Related Publications... 2 Admonishments... 2 General Safety

More information

DSXi Product Family Digital Signal Cross-Connect Panels User Manual

DSXi Product Family Digital Signal Cross-Connect Panels User Manual DSXi Product Family Digital Signal Cross-Connect Panels User Manual ADCP-80-535 Issue 2 08/2009 REAR CROSS-CONNECT PANEL FRONT-BELOW CROSS-CONNECT PANEL TOTAL FRONT-ACCESS CROSS-CONNECT PANEL FRONT-SPLIT

More information

Assembly Instructions-C12 Amphenol Triax BNC, 180 Polarity

Assembly Instructions-C12 Amphenol Triax BNC, 180 Polarity Assembly Instructions-C2 Amphenol Triax BNC, 80 Polarity Washer C Washer D Contact Inner Insulator E Inner Body F Inner Insulator G Body Nut Gasket Washer B Washer A (2 pcs. if needed) Teflon Washer 3-4774-3

More information

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP AI85112-02 Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN 858-003-02/SKT 858-032-02 CABLE: 963-033-26 S/FTP Revision History Rev Date Initiated By Approved 1 07/05/18 WLL

More information

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE: AI85114-02 Assembly Instruction EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN 858-028-01/SKT 858-029-01 CABLE: 963-118 Revision History Rev Date Initiated By Approved 1 07/16/18 WLL GH 1.0 Tools Tools

More information

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual Content PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual Page INTRODUCTION...2 Revision History...5 Trademark Information...5 Admonishments...5 General Safety Precautions...6

More information

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual ADCP-80-580 Issue 3 11/2010 17943-A Circuit Breaker for ±24 or ±48 Vdc 1474485 Rev C Preface COPYRIGHT

More information

LSW Connector Module User Manual

LSW Connector Module User Manual LSW Connector Module User Manual Content Page INTRODUCTION............................................................................. 2 Revision History........................................................................

More information

Termination Procedures for Triaxial Connectors D , D , and D

Termination Procedures for Triaxial Connectors D , D , and D Page: 1 of 7 Termination Procedures for Triaxial Connectors D-621-0001, D-621-0002, and D-621-0003 1. Scope This standard covers the procedures for terminating triaxial and twinaxial cables to the triaxial

More information

SUBMERSIBLE TRANSDUCER CABLE REPAIR

SUBMERSIBLE TRANSDUCER CABLE REPAIR SUBMERSIBLE TRANSDUCER CABLE REPAIR One of the most frequent causes of level transducer failure is its cable being cut, which allows moisture to infiltrate the transducer cable jacket. Many of our customers

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1 Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation...

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

Bel Stewart Connector

Bel Stewart Connector Individually Shielded Pair Cable END END With Orange on left and Brown on right, one end of cable has Green on top, other end has Blue on top. Green end steps will be shown on left, Blue steps shown on

More information

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series 3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working

More information

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination 3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may

More information

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D Application Specification Circular Plastic Connector (CPC) 114-13137 Series 45 System 05 AUG 14 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions

More information

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions Description The JBS-100-STB is a NEMA 4X rated power connection kit. It is designed for use with Raychem BTV-CR, BTV-CT,

More information

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316 Ver. 2.7 CASS USER S MANUAL VPC Tools Required For the assembly of the Mini-Coaxial Contact(s) VPC P/N 610 103 115/CASS P/N 1899AS284-01 and/or P/N 610 103 159/1899AS284-04 the following parts are required

More information

JUL 17 Rev M

JUL 17 Rev M Hand Crimping Tool and Cable Preparation Kit; PN 59981-1 Instruction Sheet 408-6788 24 JUL 17 Rev M PROPER USE GUIDELINES Cumulative Trauma Disorders can result from the prolonged use of manually powered

More information

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Termination 3M Cold Shrink QT-III Silicone Rubber Termination For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable 7673-S-8(S)-TOW/WOT Instructions IEEE Std. No. 48 Class 1 Termination 69 kv Class, 350

More information

QT-III Cold Shrink Silicone Rubber

QT-III Cold Shrink Silicone Rubber QT-III Cold Shrink Silicone Rubber 7600-T-3RJS Series 3/C Cabinet Termination Instructions Kit Contents: 3ÑSilicone Rubber Phase Re-jacketing Sleeve Assembly 3ÑCold Shrink Silicone Rubber Termination Assembly

More information

Quick Connection Cabinet (QCC)

Quick Connection Cabinet (QCC) Quick Connection Cabinet (QCC) Installation / Operation / Maintenance Manual 400A thru 1200A Ratings, 480Vac Max Quick Connection Cabinet Installation/Operation/Maintenance Manual Page 1 of 6 WARNING!

More information

HTP PTP/ PTJ Power Connection Kit for Pipes

HTP PTP/ PTJ Power Connection Kit for Pipes HTP 1548-40PTP/1548-40PTJ Power Connection Kit for Pipes For use with Dekoron 2700 and 2300 Families of Heating Cables. 1548-81HTJ/81HTP for use with 2000 Series Heating Cables. Installation Instructions

More information

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Class I Indoor Termination Voltage Designation: 12/20(24) kv Kit Contents: 1 HeatShrinkBreakoutBootAssembly 3 HeatShrinkBindingSleeves

More information

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS DESCRIPTION The JBS-100-A and JBS-100-A6 are NEMA 4X-rated power connection kit. It is designed for use with Raychem

More information

CASS Interface System Parts Section 1

CASS Interface System Parts Section 1 Ver. 2.7 CASS USER S MANUAL Receiver CASS Interface System Parts Section 1 VPC P/N CASS P/N Description 310 115 101 1899AS265-01 CASS Receiver Interface, accepts 19 Modules Interface Device VPC P/N CASS

More information

Coaxial Snap-Lock Connectors

Coaxial Snap-Lock Connectors Coaxial Snap-Lock Connectors Application Specification 114-13010 11 APR 13 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and

More information

3M Cold Shrink Splice Kit QS-III 5536A

3M Cold Shrink Splice Kit QS-III 5536A 3M Cold Shrink Splice Kit QS-III 5536A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric

More information

710 Splicing Rig. Instructions. January E

710 Splicing Rig. Instructions. January E 710 Splicing Rig Instructions January 2007 Table of Contents 1.0 General Statement...4 2.0 3M 710-UTK25A Splicing Rig and Field Maintenance Kit...4 3.0 Straight Splicing using the 3M 710 25-pair modules...6

More information

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc. Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series

More information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR MICRO COAXIAL CONTACTS AND MODULES TABLE OF CONTENTS SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT ASSEMBLY INSTRUCTIONS

More information

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P with Pyrotenax MI heating cable using required MI cable grounding kit SPC-P with Raychem

More information

ELB ELB

ELB ELB ELB-35-600 ELB-35-610 600A T-Body Elbow Connectors for Copper Tape (CT), Jacketed Concentric Neutral (JCN), and Concentric Neutral (CN) cables up to 35kV class Safety Instructions When installing electrical

More information

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails FIST-GSS2 FIST-GSS3 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Mounting the shelf

More information

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,

More information

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS ) Screened Separable Connectors MN650023EN Effective October 2016 Supersedes March 2012 (IS550-60-1) COOPER POWER SERIES DTS1242 Deadbreak Bolted Tee Connector: Interface C for Single Core Cable with Copper

More information

Termination Procedure for Subminiature SolderTacts Contacts for Coaxial Cable: D & D D & D

Termination Procedure for Subminiature SolderTacts Contacts for Coaxial Cable: D & D D & D Print 12-Jun-03 1 of 11 Termination Procedure for Subminiature SolderTacts Contacts for Coaxial Cable: D-602-0218 & D-602-0219 D-602-0278 & D-602-0279 1. Scope This standard contains the termination procedures,

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

UNSIGNED HARDCOPY NOT CONTROLLED

UNSIGNED HARDCOPY NOT CONTROLLED Subject: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS Flat Braid Cables Manager, Hardware Engineering Maintenance Revision Establishes the requirements for the fabrication of special-purpose electrical

More information

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS ) Screened Separable Connectors MN650024EN Effective October 2016 Supersedes March 2012 (IS550-61-1) COOPER POWER SERIES DTB1242 Deadbreak Bolted Companion Tee Connector: Interface C for Single Core Cable

More information

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Position Cat6 Shielded. Modular Plug Connectors. Application Specification Application Specification 114-93006 28/Apr/2008 Rev D 8-Position Cat6 Shielded. Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions

More information

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage FIST-GMS2 I N S T A L L A T I O N I N S T R U C T I O N FIST Generic Mixed Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1 Mounting

More information

29048, 29049, 29050, 29051, 29052, 29053, 29054,

29048, 29049, 29050, 29051, 29052, 29053, 29054, April 15, 2014 Lit. No. 29225, Rev. 11 29048, 29049, 29050, 29051, 29052, 29053, 29054, 29400 5 HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM w/2 PLUG SYSTEM HARNESSES Installation Instructions Read

More information

RG6 TLC F Hands-On. Materials Needed RG6 regular/dual coax cable Adjustable prep tool (stripper) (45-526) RG6 F TLC connector (85-168)

RG6 TLC F Hands-On. Materials Needed RG6 regular/dual coax cable Adjustable prep tool (stripper) (45-526) RG6 F TLC connector (85-168) RG6 TLC F Hands-On Materials Needed RG6 regular/dual coax cable Adjustable prep tool (stripper) (45-526) RG6 F TLC connector (85-168) Prep the RG6 Tool directions Verify grey cartridge is in the front

More information

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE 9.5 x 19 (292 mm x 509 mm) Cross-Connect Dome Closure AUGUST 2013 COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product

More information

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide) Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide) 13536-A Figure 1. ACE-200DS Enclosure With OCM-HD Panels Content Page INTRODUCTION... 2 1 PRODUCT DESCRIPTION...

More information

FAKRA Automated In-Line Connector System

FAKRA Automated In-Line Connector System FAKRA Automated In-Line Connector System Application Specification 114-32145 05 JAN 2017 Rev H All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters.

More information

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) 3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) for Tape Over Wire and Wire Over Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325

More information

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW) 3M Cold Shrink Skirted Termination Kit QT-III 7672-S-8-TS (RW) for Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325 kv BIL CAUTION Working around energized systems

More information

AMPLIMITE* HDP- 20 and Economy

AMPLIMITE* HDP- 20 and Economy AMPLIMITE* HDP- 20 and Economy Application Specification Crimp Snap Subminiature D 114-40030 Commercial s 05 MAY 11 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets].

More information

HyperJuice Magic Box User Guide

HyperJuice Magic Box User Guide Magic Box User Guide Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 21 INTRODUCTION The Magic Box modifies your existing Apple MagSafe Power Adapter for use with the HyperMac/HyperJuice

More information

Cold Shrink QS T Trifurcating Transition Splice Kit

Cold Shrink QS T Trifurcating Transition Splice Kit Cold Shrink QS2012-13-3T Trifurcating Transition Splice Kit Instructions IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice Cable Size Range Requirements PILC 500 kcmil Conductor Size (240 mm 2

More information

Instruction Sheet Crimping Die Assemblies , , and

Instruction Sheet Crimping Die Assemblies , , and Instruction Sheet Crimping Die Assemblies 08-8 986-1, 98-1, and 988-1 1 Mar 11 Moving Dies Color Code For complete instructions concerning the related applicators or machines, refer to the customer documents

More information

Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good t

Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good t How to make a ROV! Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good to have extras. Using the wire cutter,

More information

29048, 29049, 29050, 29051, 29052, 20953, 29054,

29048, 29049, 29050, 29051, 29052, 20953, 29054, July 15, 2008 Lit. No. 29225, Rev. 06 29048, 29049, 29050, 29051, 29052, 20953, 29054, 29400-2 HARNESS KIT 3-PORT ISOLATION MODULE LIGHT SYSTEM w/2-plug SYSTEM HARNESSES Installation Instructions Read

More information

COYOTE Terminal Dome Closure 6.5" x 22"

COYOTE Terminal Dome Closure 6.5 x 22 FEBRUARY 2015 COYOTE Terminal Dome Closure 6.5" x 22" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

More information

ET-PWR-END-KIT Installation Instructions (part #JSR00)

ET-PWR-END-KIT Installation Instructions (part #JSR00) (part #JSR00) Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety

More information

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating

More information

Model A Turn Signal Kit Installation Guide

Model A Turn Signal Kit Installation Guide Model A Turn Signal Kit Installation Guide Creative Connections, Inc. Consumer Hot Line: 888-471-LOGO 770-476-7322 In Atlanta, GA http://www.logolites.com P/N: 100-005/K 2008 Creative Connections, Inc.

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC For Tape Shield or Longitudinally Corrugated (LC) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

T E C H N I C A L O V E R V I E W LEMO S REMOTE HANDLING CONNECTORS N SERIES

T E C H N I C A L O V E R V I E W LEMO S REMOTE HANDLING CONNECTORS N SERIES T E C H N I C A L O V E R V I E W LEMO S REMOTE HANDLING CONNECTORS N SERIES I NTRODUCTION LEMO s N Series connectors are ideally suited for remote handling in nuclear environments. Main Features Push-pull

More information

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series

More information

SMB LOCK Introduction Characteristics Straight plugs Right angle plugs SMB limited detent (SMB-A) Receptacles...

SMB LOCK Introduction Characteristics Straight plugs Right angle plugs SMB limited detent (SMB-A) Receptacles... CONTENTS PAGE SMB Introduction... 4 General... 5 Finder guide... 6 Interface... 7 Characteristics...8-9 Straight plugs...0- Right angle plugs...- Jacks... 3 Bulkhead jacks...4-5 Receptacles...6-7 PCB receptacles...

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN For Jacketed Concentric Neutral (JCN) Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350 kv BIL IEC 60840 72,5

More information

CS Fiber Optic Splice Case. Instruction

CS Fiber Optic Splice Case. Instruction 3 2179-CS Fiber Optic Splice Case Instruction 2179-CS Fiber Optic Splice Case Description 1.0 General 1.1 The 3M 2179-CS Fiber Optic Splice Cases are closures that can be used in buried, underground, aerial,

More information

Solder Assembly Kit

Solder Assembly Kit ORIGINAL INSTRUCTIONS Solder Assembly Kit 1055420-1 Instruction Sheet 408-8677 30 APR 17 Rev C 10 12 1. INTRODUCTION Item Number TE Part Number Description Qty Per Assy 1 1055441-1 Inserts 1 2 1055440-1

More information

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits MARCH 2012 COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before

More information

General characteristics and technical data Series MCS

General characteristics and technical data Series MCS MOD M MC MCS VP 100 S Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory REAR SPOILER Application 2011 CR-Z MUGEN Publications No. AII 45919 Issue Date APRIL 2011 PARTS LIST Right wing bracket Rear wing Left wing bracket Right wing base Right

More information

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails FIST-GSS2 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1

More information

I N S TA L L AT I O N

I N S TA L L AT I O N I N S TA L L AT I O N 5008 fits: H-D: '80-Up Electra glide, tour glide, road king, road glide or street glide PartS Included 1 Right Fork Mount Assembly 1 Left Fork Mount Assembly 2 H3 Driving Light Assemblies

More information

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS ... A Vital Part of Connection World Cable Connectors PCB Connectors s Mounting Holes MCX CONNECTORS COPYRIGHT ELECTRONICS 0 MCX Series Coaxial Connectors DESCRIPTION MCX connector are developed in Europe

More information

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION May 1, 2018 Lit. No. 92991, Rev. 00 HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM Parts List and Installation Instructions Read this document before installing the snowplow. See your sales outlet/website

More information

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE 28 GLC (Ground Level Closure) Complete Assembly Installation NOVEMBER 2016 COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED

More information

29048, 29049, 29050, 29051, 29052, 29053, 29054,

29048, 29049, 29050, 29051, 29052, 29053, 29054, May 1, 2018 Lit. No. 29206, Rev. 13 29048, 29049, 29050, 29051, 29052, 29053, 29054, 29400 7 HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM w/3 PLUG SYSTEM HARNESSES Installation Instructions Read this

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING KURYAKYN! Protect yourself and others from possible injury and property damage or loss. Pay close attention to all instructions, warnings, cautions, and notices regarding the installation,

More information

Installation Instructions

Installation Instructions 4140 World Houston Pkwy., Ste. 130 Houston,TX 77032, LA Ph: (281) 445-7400 Fax: (281) 445-7404 www.rigpower.com Installation Instructions for VFD-1 Series Connectors Female Cable End Assembly The cable

More information

MX Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable

MX Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable MX8020-001 Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable The Metrix MX8020-001 Cable Trimming and Connector Kit provides an easy way

More information

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number Model

More information

INSTALLATION CLAMP-ON FORK MOUNTED DRIVING LIGHTS 5015

INSTALLATION CLAMP-ON FORK MOUNTED DRIVING LIGHTS 5015 CLAMP-ON 5015 PARTS INCLUDED 2 Driving Lights 2 Side Mount Clamps-43mm/49mm 1 Hardware Kit Including: 2 49mm Spacers 4 43mm Spacers 2 Pivot Dome Washers 2 3/8-16 Serrated Hex Nut 1 Wiring Kit for Driving

More information

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser INSTRUCTIONS-PARTS LIST 30 455 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supercedes B Hand-Operated Portable Grease Dispenser Buckshot Luber

More information

B29048, B29049, B29050, B29051, B29053, B

B29048, B29049, B29050, B29051, B29053, B May 1, 2011 Lit. No. 48266, Rev. 05 B29048, B29049, B29050, B29051, B29053, B29400-5 HARNESS KIT 3-PORT ISOLATION MODULE LIGHT SYSTEM w/2-plug SYSTEM HARNESSES Installation Instructions Read this document

More information

Service Procedure Note Note Note

Service Procedure Note Note Note Service Procedure Use wiring harness connector kit, P/N 13580234 on 2009 model year vehicles. The 2009 model year kit includes the material required to service a 4-way connector. The service procedure

More information

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

COYOTE 9.5 x 19 (292 mm x 509 mm) Dome Closure AUGUST 2012 COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

More information

Stainless Steel Air Motor Conversion Kits

Stainless Steel Air Motor Conversion Kits Instructions Stainless Steel Air Motor Conversion Kits 096D Conversion Kit 650 For 00 Pumps Conversion Kit 65 For 590 Pumps Conversion Kit 65 For 50 Pumps Model 650 Model 65 Model 65 Installation Pressure

More information

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Instructions for Shielded and Belted PILC Cable IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice UniShield Wire Shielded Longitudinally

More information

USB Charge Port Installation Instructions

USB Charge Port Installation Instructions USB Charge Port Installation Instructions Lifetime Technical Support support@logolites.com 770-476-7322 www.logolites.com Manual 100-0014C Thank you for purchasing a Logo Lites USB Charge Port! USB Charge

More information

S6 BATTERY REPLACEMENT

S6 BATTERY REPLACEMENT S6 BATTERY REPLACEMENT Supplemental Instruction Guide P/N 108304 Battery Pack Removal Tools Required: S6 Operation & Parts Manual, Phillips Head Screwdriver, Needle Nose Pliers, Wire Stripping / Crimping

More information

3 Reenterable Encapsulated PST Dome Closure

3 Reenterable Encapsulated PST Dome Closure 3 Reenterable Encapsulated PST Dome Closure Instructions July 1998 34-7037-1080-5-B 1 Contents: 1.0 General...3 2.0 Kit Contents...3 3.0 PST Closure Capacity...3 4.0 Cable Preparation...4 5.0 Bonding and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING KURYAKYN! Protect yourself and others from possible injury and property damage or loss. Pay close attention to all instructions, warnings, cautions, and notices regarding the installation,

More information

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)

More information

UES-LL End Termination Kit

UES-LL End Termination Kit Installation Instructions UES-LL End Termination Kit for Series Long Line Heating Cables 1 PJ950 161-562681-022 July 2015 UES-LL End Termination Kit Kit Contents Item Qty Description Item Qty Description

More information