Cooper B-Line RESIDENTIAL SERVICES

Size: px
Start display at page:

Download "Cooper B-Line RESIDENTIAL SERVICES"

Transcription

1 RESIDENTIAL SERVICES Approved Voltage Optional Voltage w/utility Approval th Clip 100 Amp Socket Only, Overhead 011F 011F 5 th Clip 100 Amp Meter Socket & Circuit 1M1R 1M1R 5 th Clip Breaker Overhead 1M1RF 1M1RF 5 th Clip 100 Amp Socket Only, UG204 UG204F UG204 5 TH Clip UG204F 5 TH Clip 100 Amp Meter Socket & Circuit Breaker U1M1R U1M1RF U1M1R 5 th Clip U1M1RF 5 th Clip 200 Amp Socket Only, Overhead F th Clip 204F 5 th Clip 200 Amp Meter Socket & Circuit 2M2R 2M2R 5 th Clip Breaker Overhead 2M2RF 2M2RF 5 th Clip 200 Amp Socket Only, UG204 UG204 5 th Clip UG204F UG204F 5 th Clip Note: This list of approved manufacturer s meter equipment is indicative of many of the types of equipment that is acceptable but is not an exhaustive list of all possible acceptable versions manufactured by a particular company. The general guidelines to consider when selecting meter equipment not shown is that PacifiCorp: Requires EUSERC approved metering equipment Requires screw-type meter ring Aluminum snap rings not allowed Requires manual link bypasses--lever bypasses and automatic bypasses not allowed. Requires that all non-residential meter sockets shall have manual link bypass or safety socket. Requires ANSI detachable type meter socket--no A-base or K-base sockets. Requires all sockets shall be ring types--ringless not allowed. Allows single and polyphase direct connect sockets up to a maximum of 225 amperes. Allows 400 ampere direct connect sockets with manual link bypasses for single phase only. Requires that safety sockets be on all commercial polyphase services and on single-phase 480-volt services. Jan Page 1

2 RESIDENTIAL SERVICES 200 Amp Meter Socket & Circuit Breaker 400 Amp Socket Only, Overhead 400 Amp Socket Only, 400 Amp Meter Socket & Circuit Breaker Approved Voltage Optional Voltage w/utility Approval U2M2R U2M2R / KIT U2M2RF U2M2RF / KIT N 324N 324C NA NA 324C w/fk2432 NA U404MCC U404MCC/FK2438 NA Jan Page 2

3 COMMERCIAL SERVICES Approved Voltages Optional Voltages with Utility Approval 277/480V 1 PH 3W 100 Amp Socket Only, Overhead U264 Note 1 114TB 114TB or U264 U264F 114TBF 114TBF F F /FK Amp Meter Socket & Circuit Breaker Overhead 214MTB 214MTBF 217MTB 217MTB 217MTBF 214MTB 214MTBF 214MTB 214MTBF 217MTB 217MTBF 217MTB 217MTBF 100 Amp Socket Only, U264 Note 1 114TB 114TB or U264 Note1 U264F F F 114TBF 114TBF F F 100 Amp Meter Socket & Circuit Breaker U214MTB U214MTBF F F U214MTB W/50365 U214MTBF U214MTB U214MTBF F F W/50365 Note: U does not meet minimum dimensions Jan Page 3

4 COMMERCIAL SERVICES Approved Voltages Optional Voltages with Utility Approval 277/480V 1 PH 3W 200 Amp Socket Only, Overhead U264 U264F F F F F F F 200 Amp Meter Socket & Circuit Breaker Overhead 224MTB 224MTBF 227MTB 227MTBF 227MTB 227MTBF 224MTB 224MTBF 224MTB 224MTBF 227MTB 227MTBF 227MTB 227MTBF 200 Amp Socket Only, 5 th Clip F F F 124 TBF 5 th Clip F F F 200 Amp Meter Socket & Circuit Breaker, U224MTB U224MTBF U227MTB U227MTBF U227MTB U227MTBF U224MTB W/50365 U224MTBF U224MTB U224MTBF U227MTB U227MTBF U227MTB U227MTBF W/50365 Jan Page 4

5 COMMERCIAL SERVICES Approved Voltages Optional Voltages with Utility Approval 277/480V 1 PH 3W 400 Amp Socket Only, Overhead 324N Not Approved Not Approved Not Approved Not Approved Not Approved Not Approved 324N 400 Amp Meter Socket & Circuit Breaker U404MCC U404MCC W/FK2432H Not Approved Not Approved Not Approved Not Approved Not Approved Not Approved 400 Amp Socket Only, 324C 324C Not Approved Not Approved Not Approved Not Approved Not Approved Not Approved w/fk Amp Meter Socket & Circuit Breaker U404MCC U4042MCC W/FK2438 Not Approved Not Approved Not Approved Not Approved Not Approved Not Approved Jan Page 5

6 OUTDOOR BUSSED WIREWAYS Meter Positions Outdoor Bussed Gutter 1 PH. 3W 3 PH. 4W Ampere Rating Catalog No. Catalog No. AIC Rating 400 R1024 HC R1024 HCC 42, R1036 HC R1036 HCC 42, R1048 HD R1048 HDD 42, R1060 HC R1060 HDD 42, R1072 HC R1072 HEE 42, R1096 HCC 42, R1036 HD R1036 HDD 42, R1048 HD R1048 HDD 42, R1060 HD R1060 HDD 42, R1072 HD R1072 HDD 42, R1096 HDD 42, R10120 HDD 42, R1048 HE R1048 HEE 65, R1060 HE R1060 HEE 65, R1072 HE R1072 HEE 65, R1096 HEE 65, R10120 HEE 65, R1060 HFF 65, R1072 HFF 65, R1096 HFF 65, R10120 HFF 65, R1072 HGG 65, R1096 HGG 65, R10120HGG 65, R1072 HHH 65, R1096 HHH 65, R10120 HHH 65,000 Jan Page 6

7 Note: All meter sockets require safety sockets with test block bypass. TRANSFORMER RATED SERVICES (Commercial) Approved Voltages Optional Voltages w/utility Approval 120/ /480V 3 PH 4W 3 PH 4W 3 PH 3W 3 PH 3W 3 PH 4W 3 PH 4W 6 Terminal 13 Terminal 13 Terminal 8 Terminal 8 Terminal 13 Terminal 13 Terminal 20 Amp Socket with Provisions for a Test Switch Jan Page 7

8 The Copper B-Line CT cabinets are no longer approved for use. The cabinets do not meet PacifiCorp ESR and EUSERC specifications which require a device to hold the cover in the open position at 90 degrees or more. Current Transformer Mounting Base 50,000 AIC requires two hole compression (crip) connectors Line & Load Phase Voltage Transformer Capacity Catalog No. 1 or 3 PH, 3W CT s 800 Amps or Less 6019-HE 1 or 3 PH, 3W CT s 800 Amps or Less 6019-HELS Line Side Studs Only 3 PH, 4W CT s 800 Amps or Less 6067-HEE 3 PH, 4W CT s 800 Amps or Less 6067-HEELS Line Side Studs Only Current Transformer Mounting Base 50,000 AIC with built in barrel connectors Line & Load Side (hex compression lugs) Phase Voltage Transformer Capacity Catalog No. 1 or 3 PH, 3W CT s 800 Amps or Less 6019-HEL 3 PH, 4W CT s 800 Amps or Less 6067-HEEL Current Transformer Cabinet Phase Voltage Size Catalog No. 1 or 3 PH, 3W x48x HRTCT 3 PH, 4 W x48x HRTCT Jan Page 8

9 Bussed Termination Enclosures Service Amperage All Single Phase Services All Three Phase Services Amp R9000B R9000BB Amp R9000C R9000CC Amp R9000E R9000EE Amp R9000F R9000FF Termination Enclosure Service Amps Volts A.I.C. Rating Catalog No. 1 or 3 PH, 3W k P9000CL 3 PH, 4W k R9000CCL 1 or 3 PH, 3W k R9000EL 3 PH, 4W k R9000EEL 1 or 3 PH, 3W k R9000FL 3 PH, 4W k R9000FFL Jan Page 9

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

Meter Mains - With Optional MCC Bypass

Meter Mains - With Optional MCC Bypass Meter Mains - With Optional MCC ypass pplication Combination meter/main with optional manual circuit closing (link type) bypass Factory installed breaker Receive SI C12.10 watthour meters Surface mount

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Meter Centers Meter Mounting Devices

Meter Centers Meter Mounting Devices Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless

More information

Electric Service Information Equipment Only Contents..Page. Socket Selection Table...2. Self Contained Meter Sockets...3

Electric Service Information Equipment Only Contents..Page. Socket Selection Table...2. Self Contained Meter Sockets...3 JO-CARROLL ENERGY 793 U. S. ROUTE 20 WEST P. O. BOX 390 ELIZABETH, IL 61028 815/858-2207 800/858-5522 FAX: 815/858-3731 Electric Service Information Equipment Only 2006 Contents..Page Socket Selection

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Customer Requirements Meter Socket Configurations

Customer Requirements Meter Socket Configurations Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

SIEMENS RESIDENTIAL SERVICES. 120/240V 1 PH 3W 4 Terminal 100 Amp Socket Only, Overhead Surface Use 200 Amp socket (SUAT327-OGWR)

SIEMENS RESIDENTIAL SERVICES. 120/240V 1 PH 3W 4 Terminal 100 Amp Socket Only, Overhead Surface Use 200 Amp socket (SUAT327-OGWR) RESIDENTIAL SERVICES 100 Amp Socket Only, Overhead Use 200 Amp socket (SUAT327-OGWR) 100 Amp Meter Socket & Circuit Breaker Combination, Overhead SUAT327-OGWR + EC659-0121 MM0406L1125SEC*, MC1224B1100SEC,

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

Metering NEED. Meter Sockets. Product Description

Metering NEED. Meter Sockets. Product Description Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)

More information

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

SAFETY SOCKET BOX. Note 8 3 MIN. 3 Max. (200 A) .&. SAFETY SOCKET BOX USE: 1 12/24V 1A & 2A 4 Terminal EUSERC Dwg. No's 34 & 35 (With Factory Installed Test-Bypass Facilities) Refer to SR-452 for the complete Front View Lower-Panel Removed Note 3 3"

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location.

PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location. I N T R O D U C T I O N - M-1 RIGHTS: PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location. NOTIFICATION: Customers planning to install or

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

ELECTRICAL METERING RESIDENTIAL

ELECTRICAL METERING RESIDENTIAL ELECTRICAL METERING RESIDENTIAL 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 UNDERGROUND FED METER SOCKET (226-320 AMPS) 5.0 METER SOCKET (0-320 AMPS, 120/208V) 6.0 UNDERGROUND SERVICE W/CURRENT

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements- A.) Shall be tested and certified

More information

10. METERING General Requirements

10. METERING General Requirements 10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,

More information

Multiple Metering, Vertical Gang

Multiple Metering, Vertical Gang Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or

More information

Selection and Application Guide For use in New England EQUIPMENT

Selection and Application Guide For use in New England EQUIPMENT Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Colorado and Wyoming Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

Approved Meter Sockets for Use in. New Jersey, Delaware, Maryland. Issued 7/07/07 Revised 1/19/2018 Page 1 of 9 Atlantic City Electric/Delmarva Power

Approved Meter Sockets for Use in. New Jersey, Delaware, Maryland. Issued 7/07/07 Revised 1/19/2018 Page 1 of 9 Atlantic City Electric/Delmarva Power Approved Meter Sockets for Use in New Jersey, Delaware, Maryland Page 1 of 9 1. INDEX. 2 2. INTRODUCTION.. 3 2. RESIDENTIAL & COMMERCIAL METER SOCKETS.. 3-4-5 2. SINGLE PHASE GANG SOCKETS 6 3. THREE PHASE

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Instrument Rated Metering Equipment

Instrument Rated Metering Equipment Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions

More information

RESIDENTIAL. Metering Guidelines for Electric Service. Meter Standards. October 25, 2017

RESIDENTIAL. Metering Guidelines for Electric Service. Meter Standards. October 25, 2017 Meter Standards RESIDENTIAL Metering Guidelines for Electric Service October 25, 2017 13315 Goodnough Drive NW Gig Harbor WA 98332-8640 Phone (253) 857-1547 Fax (253) 857-1557 www.penlight.org Residential

More information

OVERHEAD SERVICE. Items to consider

OVERHEAD SERVICE. Items to consider OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must

More information

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Selection and application guide. For use in Texas. Meter Mounting Equipment. Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General

More information

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT 2011 81 APPENDIX A: APPROVED METERING EQUIPMENT TABLE OF CONTENTS Approved Metering Equipment... A-1

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Meter Installation. -and- Padmount Transformer Guide

Meter Installation. -and- Padmount Transformer Guide Meter Installation -and- Padmount Transformer Guide Feb. 2016 METERING REQUIREMENTS The following information shall be used as a guide for installing metering equipment. A self-contained meter has all

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At

More information

Power Mod. Standard Tapboxes.

Power Mod. Standard Tapboxes. Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility:

More information

Chapter 2 ELECTRIC SERVICE EQUIPMENT EQUIPMENT - METER CABINETS Issued Jan. 2016

Chapter 2 ELECTRIC SERVICE EQUIPMENT EQUIPMENT - METER CABINETS Issued Jan. 2016 ELECTRIC SERVICE EQUIPMENT EQUIPMENT - METER CABINETS Issued Jan. 2016 ELECTRIC SERVICE EQUIPMENT METER CABINETS CHAPTER 2 E200. TECHNICAL SPECIFICATIONS FOR METERING TRANSFORMER CABINETS AND CONDUCTOR

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long

More information

Modular Metering Application Guide. Meter Mod * III Product Family

Modular Metering Application Guide. Meter Mod * III Product Family Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family

More information

SPEEDFAX TM 2011 Meter Centers Contents

SPEEDFAX TM 2011 Meter Centers Contents SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016 DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all

More information

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,

More information

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment. GA/AL/FL Panhandle Area Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke

More information

Ohio Meter Mounting Equipment

Ohio Meter Mounting Equipment Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units

Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric

More information

PSE&G Long Island Meter Mounting Equipment

PSE&G Long Island Meter Mounting Equipment PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue

More information

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION REVISED 10/03/17 Specifications for Residential Construction Revision List REVISION Date Page No. Description 8/18/09 T.O.C., 8.1-8.1.5 &

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -

More information

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets .1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are

More information

Louisiana & Mississippi Area Catalog

Louisiana & Mississippi Area Catalog Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Meter Mounting Equipment. Northern Indiana Public Service Co.

Meter Mounting Equipment. Northern Indiana Public Service Co. Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop

More information

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

ComEd Service Area Meter Mounting Equipment

ComEd Service Area Meter Mounting Equipment ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Louisiana and Mississippi Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Metering and Service Installation:

Metering and Service Installation: Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...

More information

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy

More information

Consolidated Edison Orange & Rockland Meter Mounting Equipment

Consolidated Edison Orange & Rockland Meter Mounting Equipment Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Louisiana/Mississippi. Area Catalog

Louisiana/Mississippi. Area Catalog Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.

More information