RS308-PV-3E Midget Fuse
|
|
- Stella Waters
- 5 years ago
- Views:
Transcription
1 RS308-PV-3E Series V Midget Fuse SJ1038 Clip Conform to IEC60269 & UL2579 & GB13539 Rated Voltage: DC1000V (L/R=1~3ms), C1000V (COSΦ 0.5) Rated Current: 1~25 Protection: IEC gpv (General PV Protection) & UL PV Interrupting Rating: please refer to table below TUV,CE,CGC,ROHS Compliant Clip Mounting vailable Fuse Holder TS1038 vailable Fast acting general current limitation fuse, able to protect PV battery systems, batteries and other applicable circuits. No Model Size Current Prearc I²t 10k Interrupt 1000VDC L/R=1~3ms eight g 1 RS308-PV-3E RS308-PV-3E RS308-PV-3E RS308-PV-3E RS308-PV-3E5 Fig RS308-PV-3E ±5% RS308-PV-3E RS308-PV-3E RS308-PV-3E RS308-PV-3E RS308-PV-3E k RS308-PV-3E k Voltage Current No Model Size eight V g 0.8I n I n 1 SJ1038 Fig ±10% Suit Φ10 fuse, any length Fuse Size Fig 1 SJ1038 Fuse Clip Fig 2 38 ± ±0.5 φ1 0.3± ±0.2 11±0.2 Version 3 1
2 RS308-PV-3E/EB/EC Series V Pinned Fuses Conform to IEC60269 & UL2579 & GB13539 Rated Voltage: DC1000V (L/R=1~3ms), C1000V (COSΦ 0.5) Rated Current: 1~25 Protection: IEC gpv (General PV Protection) & UL PV Interrupting Rating: please refer to table below TUV,CE,CGC,ROHS Compliant Three mounts: 3E--Single Pole, eldable 3EB--Double Pole, eldable 3EC--L-Slot, Screw Mount Fast acting general current limitation fuse, able to protect PV battery systems, batteries and other applicable circuits. No 3E Single Pin (Size 1) 3EB Double Pin (Size 2) 3EC Stud-Mount (Size 3) Current Prearc I²t 10k 1 RS308-PV-3E1 RS308-PV-3EB1 RS308-PV-3EC RS308-PV-3E2 RS308-PV-3EB2 RS308-PV-3EC RS308-PV-3E3 RS308-PV-3EB3 RS308-PV-3EC RS308-PV-3E4 RS308-PV-3EB4 RS308-PV-3EC RS308-PV-3E5 RS308-PV-3EB5 RS308-PV-3EC RS308-PV-3E6 RS308-PV-3EB6 RS308-PV-3EC RS308-PV-3E8 RS308-PV-3EB8 RS308-PV-3EC RS308-PV-3E10 RS308-PV-3EB10 RS308-PV-3EC RS308-PV-3E12 RS308-PV-3EB12 RS308-PV-3EC RS308-PV-3E15 RS308-PV-3EB15 RS308-PV-3EC RS308-PV-3E20 RS308-PV-3EB20 RS308-PV-3EC k RS308-PV-3E25 RS308-PV-3EB25 RS308-PV-3EC k 3.9 IR 3E Single Pin Size 1 3EB Double Pin Size 2 (9.5) 40±0.6 (9.5) 7 (9.9) 40.5±0.6 (9.9) EC Stud-Mount Size ±1 6 40± ±1 6 Version 3 2
3 RS308-PV-3E/EB/EC Series V Pinned Fuses Time-Current DC Limitation 1000VDC,L/R=2ms,Typical Testing Data Rated Prospect Peak Let-Thru Prospect Peak Let-Thru Comment 4 10, , , , , , , , , , Pure silver conductor, fast acting, low Jouls, corrosion proof and long service life. Superior corundum ceramic has excellent mechanical and breakdown strength performance, thermal shock resistance up to 800K, safe and reliable. Version 3 3
4 TS1038 Fuse Holder TS1038 Fuse Holder (Mount as Module) Conform to IEC60269 & IEC60947 & GB13539 & UL2579 Rated Voltage: 1000VDC & 800VC & 690VC Rated Current: & 1000VDC Housing Thermal Resistance: UL94V-0 DIN Rail Size: TH35/7.5 TUV,CE,CGC and RoHS Compliant Suitable for φ10*38 Cylindrical Fuse Terminal Torque: 1.7N.m (14.75IN.LBS)~2.0N.m (17.7IN.LBS) Copper Conductor Cross Section: 2.5~10mm 2 (14~6G) Model Multi-Poles Poles Single Short Double Triple Double Triple Connect Indicator ithout ith ithout ith Model TS1038 TS1038-Z TS TS TS1038-Z2 TS1038-Z3 TS1038-D Size Conditions Fuses can be safely used in the following conditions. Please contact us if unsure. mbient: -25 ~ 80 Housing withstand: -25 ~120 Indicator: -25 ~95 mbient Temperature -- Rated Current Derating: mbient < Derating Storage Temp: -25 ~ 40 ltitude: not exceeding 2000m If altitude exceeds 2000m, voltage derating is required. For m,voltage should be 10% derated for each 1000m higher. tmosphere: clean air, RH below 50% at 60. t lower temperature, RH can be higher. E.g. RH can be 90% at 20. Due to temperature variation, certain extent of dewing might occur. arning: 1.Not designed for onload operation. 2.Ensure polarity is correct! Otherwise loop may be formed and resulting voltage superimposition. If voltage exceeds rated value, capability of fuse to interrupt current would be set back. Storage RH: 90% Version 3 4
5 TS1038 Fuse Holder TS1038 Fuse Holder - Mounting Instructions Instructions 1.Release Pusher 2. Lock onto Rail 3.Install Fuse 4. Dismount Holder Note: be gentle while handling. If pusher is fractured, remove holder from rail end, or press down pusher from rear to release. Version 3 5
fuse-links & fuse holders PHOTOVOLTAIC
fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38
More informationINDUSTRIAL CYLINDRICAL FUSE LINKS
gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal
More informationFUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS
1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS
More informationPage 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.
Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated
More informationFuse holders and fuses
Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator
More informationNH Solid Blades 690 VAC sizes 000 to 3
NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS
More informationModulostar US10 Modular fuse-holders
Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards
More informationXL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series
Description: A range of XL package fuse links specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents
More informationThermal-Magnetic Circuit Breaker 2210-S291-P9M A
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact
More informationProtistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationHelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationMedium voltage fuses Medium voltage fuses
European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A
More informationRated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM
IEC High speed catalogue 10x38mm, PVM Series 600Vdc (UL), 4 to 30A A range of UL 2579 fast-acting 600Vdc midget fuse links specifically designed to protect solar power systems in extreme ambient temperature,
More informationNH fuse-links am VAC with striker, size 0, 1, 2, 3, 4
NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,
More informationLimitor -G General Purpose Fuses
Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear
More informationBussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A
Technical Data Effective March 0 Bussmann x38mm Photovoltaic fuses Operating class gpv and UL PV fuse links PV Fuse coordination With thin film cells and, 5 and crystalline silicon cells Description A
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have
More informationURDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.
Fuses for PV Semiconductor Protection Class: gpv 0 Voltage ratings: 600V DC to 1500V DC Current ratings: 1 A to 450 A Standards: UL 2579 IEC 60 269-6 Approvals: E341342 E341490 Features and Benefits High
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More informationNH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a
LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection
More informationNH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More informationBussmann series NH photovoltaic fuse links
Technical Data 72033 Supersedes April 204 Bussmann series NH photovoltaic fuse links BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed
More informationHV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017
HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationNH DIN Dual Indication Fuse Links
Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.
More informationSelector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits
Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design
More informationCENTRE FEED UNIT UP TO 4000A. Safety
CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support
More informationNH photovoltaic fuse links
Technical Data 72033 Supersedes January 207 BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed to protect and isolate photovoltaic array
More informationCYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC
fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube
More informationNH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am
More informationXL Photovoltaic fuse links
Technical Data 020 Supersedes November 207 BUSSMANN SERIES Product description Eaton s Bussmann series XL fuse links are specifically designed to protect and isolate photovoltaic array combiners and disconnects.
More informationNH fuse-links am 690VAC top indicator/live tags size 4, 4a
NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %
More informationComplete and reliable solar circuit protection
Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationNEOZED D0 fuse-links gg 400/440VAC
NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationHHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.
HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More informationHelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationCylindrical fuse-link
ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5
More informationSafety switches for hinged doors
4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationSemiconductor Fuses European Fuses
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos
More informationonlinecomponents.com
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current
More informationThermal-Magnetic Circuit Breaker 201/-WA
Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring
More informationRange : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.
164 Fuse Holder consisting of carrier and base for mounting fuse links have been in use for long. Keeping operators safety and ease / reliability of removal in mind, a complete range of unique CAM operated
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationFUSES. Safety through quality
Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced
More informationHelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC
HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic
More informationFUSE BASES NH FUSE BASES 690V 160A 160A
fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationTMC 91H is now TMC 60 C Series
TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the
More informationCYLINDRICAL. fuse holders
fuse holders CYLINDRICAL 04 07 PMC MODULAR FUSE COMPACT HOLDERS 07 -CC FOR CC CLASS FUSE-LINKS 08 PMF 09 SC SCREW FIXING 10 PMB PLUG CONNECTION 10 CLIP CONTACT FOR φ10 FUSE-LINKS 09 BAC OPEN FUSE BASES
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationDIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.
DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationPositive Temperature Coefficient (PTC) Data Sheet
Positive Temperature Coefficient (PTC) Data Sheet Description The 0805 series provides miniature surface mount resettable overcurrent protection with holding current from 0.1A to 1.1A. This series is suitable
More informationSection Contents. Disconnect Switches
Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationPANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality
PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationRefer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A
TYPE KAB (P-KAB-E004) Type KAB micro fuse is designed for circuit protection against excessive current in portable electronic equipment, electronic circuit around battery, etc. because the demand for high
More informationE 90 range of fuse disconnectors and fuseholders Uncompromising performance
E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationHHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.
HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More information500V / V /
LOAD BREAK SWITCHES 125-630 A TECHNICAL DATA ATEX RoHS Compliant 2002/95/EC LOAD BREAK SWITCHES 16A 25A 40A 63A 80A 125A 160A KU / KU / KU / KU / KU / KU / VKA / VKA / KUE KUE KUE KUE KUE KUE EVA EVA VKA
More informationNDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.
Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationFuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4
URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4
More informationFeatures. Figure 1. Block Diagram. Figure 2. Input - Output DC Voltage
Features CBAM PQ-28 The Power Quality Module (PQ-28) is a single input power conditioning module 1/2 brick package (2.28 x 2.4 x 0.50 ) Designed for 200 Watts Designed to interface with MIL-STD-1275B,
More informationTHIS PAGE WAS INTENTIONALLY LEFT BLANK.
THIS PAGE WAS INTENTIONALLY LEFT BLANK. Table of Contents Features... 2 Applications... 2 Approvals... 2 Part Marking... 3 System... 4 Absolute Ratings... 4 Fuse Configuration and Dimensions... 5 Specifications...
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationBritish BS 88 Fuses. High Speed Fuses. Introduction. General Information
British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationSolar circuit protection application guide. Complete and reliable solar circuit protection
Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic
More informationID ID. Series 19. Mechanical Products Company
H i g h A m p e r a g e 2 5 t o 2 0 0 A M P New LED tripid ID ID TM Option T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 & I P 6 9 K W a t e r p r o o f I g n i t i o n - P r o t e c t e
More informationgg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES
, am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationJtec 10kA Miniature Circuit Breaker
EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in
More informationAccessories. For product data sheets, visit
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationManual Motor Protectors
88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)
More informationLow-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses
Technical Data 6 Supersedes August 2015 Low-Peak LPJ Class J 600Vac/Vdc, 1-60A, Catalog symbol: LPJ-(amp)SP (non-indicating) LPJ-(amp)SPI (indicating) Description: Bussmann series Ultimate protection LPJ
More informationAccessories Miniature Relay PT
Accessories Miniature Relay PT Easy replacement of relays on a densely packed DIN rail Socket with logical arrangement of control/load terminals High quality rising clamp terminals Captive combination
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector
Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase
More informationSelector guide. PSC Square body fuses Size 3X VAC Blade Terminals. Features and Benefits
Selector guide PSC Square body fuses Size X 500 700C Blade Terminals October 201 Issue 1 The IXYS UK range of 700/690 protistor fuse links provides maximum flexibility in equipment design and ultimate
More information