URDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.

Size: px
Start display at page:

Download "URDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC."

Transcription

1 Fuses for PV Semiconductor Protection Class: gpv 0 Voltage ratings: 600V DC to 1500V DC Current ratings: 1 A to 450 A Standards: UL 2579 IEC Approvals: E E Features and Benefits High interrupting ratings up to 30kA Low I 2 t values Fuse accessories available - Microswitches, Fuse Bases, 499

2 UL 2579 Article Description Selection Guide Technical Data 600V DC NH00, DIN 80 With blown fuse indication With fitting for microswitch 1000V DC x38mm x38mm - PCB Mount x38mm mm mounting centers x38mm - For cable connection 1100V DC x65mm x65mm mm mounting centers /14x85mm clip mounting x65mm for cable connection NH1XL SQB1 - US Short NH2XL SQB2 - US Short SQB0 - M SQB1 - M SQB2 - M SQB3 - M DC LDC DC LDC - Fuse Modules 10mmx38mm 1-Pole, 1000V DC w/ Neon Lamp Indicator mmx38mm 2-Pole, 1000V DC w/ Neon Lamp Indicator - Fuse Base For use with microswitch 513 Fuse Base NH00 DIN80 With terminal covers Fuse Base NH1XL 508 Fuse Base NH3L A-200A, 3/0-10 CU9Al 200A-450A, 600kcmil -4/0CU9AlCU9Al A-450A, 2x250kcmil -6CU9Al 200A-450A, 2x250kcmil -6CU9Al Fuse base for Fuse Base NH00 DIN PV1 Fuse Base PV2 Fuse Base PV3 Fuse Base PV4 Fuse Base Fuses for PV Semiconductor Protection & With fitting for microswitch NH3L With fitting for microswitch SQB2 - US Long With fitting for microswitch 1500V DC SQB3 - US Short NH1XL - Knife blade NH1XL - With fitting for microswitch NH2XL - Knife blade With fitting for microswitch NH3L - Knife blade SQB0 - US Short SQB2 - US Short SQB3 - US Short 14mmx65mm With fitting for microswitch

3 UL 2579 Fuse - Microswitcc Microswitch Fuse Clips mm, PCB mounting mm, PCB mounting mm, screw mounting Clamping plate for Terminal link for mm, screw mounting Clamping plate for Fuse Clips mm, PCB mounting Grip Handle - Fuse Insertion-Removal Tool Standard NH00-3, 690V AC w/leather Sleeve NH4a & NH4, 690V AC w/leather Sleeve NH3, 1600V AC Standard NH3, 1600V AC w/leather Sleeve

4 E Rated Voltage [Un] 600V DC Rated Breaking Test Capacity Voltage 30kA (L/R=1-3ms) 600V DC (UL) Class gpv Standard(s) UL 2579 IEC Size NH00 - DIN 80 Rated Current I n Without indicator With Top Indicator With Top Indicator Power Pre-arcing Total and Fitting for DC [A] Article Number UL Article Number UL Article Number UL [W] [A 2 s] [A 2 s] Weight [kg / 1] 0.78 Units per Package 1 IEC Part Numbers IEC - Contact SIBA for Data Sheets (Amp) (Amp) Loss I 2 t I 2 t* Microswitch / Article Number 2 Fuse Base Page Article Number Microswitch - GL 80mm center, w/insulated covers Standard (Black Hammer) mm center, use w/microswitch Page

5 E Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL V DC 30kA (L/R=1-3ms) 1100V DC (UL) IEC Size NH00 - DIN 80 Coefficients for Heavy Duty Applications a A2 B1 B2 Cf Time-Current Characteristics Virtual Pre-arcing time - [s] R.M.S. Prospective Current [A] 503

6 Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 E V DC 30kA (L/R=1-3ms) 1000V DC (UL) 1000V DC (IEC) IEC Size 10x38mm Rated Current I n Without indicator Without indicator Without indicator Without indicator Power Pre-arcing Total PCB 50.6mm Offset Tabs Loss I 2 t I 2 t* Mounting for cable attachment [A] Article Number UL Article Number UL Article Number UL Article Number UL [W] [A 2 s] Power loss limit of fuse base has to be considered DC [A 2 s] Article No. 1-Pole DC LDC 2-Pole DC LDC Article Number Fuse Clips 10mm PCB PCB Screw Mounting DC Series for 10x38mm 1000V DC Fuse Links E Page x38mm DIN Rail Mounting Rated voltage; IEC/UL 1000V DC / 690V AC Rated current; 30A UL, 32A IEC Power acceptance; 4W Utilization category; AC - 21B 690V AC, DC - 20B 1000V BC Rated insulating voltage; > 6kV Contacts; copper-silver plated Conductor; 0.75mm 2-16mm 2 solid wire or stranded wire Maximum torque; 2.5N m Degree of protection; IP-20 * ( cable size < 6mm 2 contact SIBA) Construction, body & handle; Thermoplastic Polyester Flammability "UL 94"; V0 Rating of indicator; 0V DC V DC Storage & Operating temperature range; -50 C to +85 C ** * Operating temperaure depends upon connections and mounting parts ** Avoid handling of lever during installation or maitenance below -20 C Important: DO NOT OPEN UNDER LOAD! Article Number Page 504

7 Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 E V DC 30kA (L/R=1ms) 1000V DC (UL) IEC Size 10x38mm Coefficients for Heavy Duty Applications a A2 B1 B2 Cf Time-Current Characteristics Virtual Pre-arcing time - [s] R.M.S. Prospective Current [A] Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 E V DC 30kA (L/R=1-3ms) 1000V DC (UL) IEC V DC (IEC) Size 14x51mm New Contact SIBA Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 E V DC 30kA (L/R=1-3ms) 1000V DC (UL) IEC V DC (IEC) Size 22x58mm New Contact SIBA 505

8 E Rated Voltage [Un] 1100V DC Rated Breaking Test Class Standard(s) Capacity Voltage gpv UL kA (L/R=1ms) 1100V DC (UL) IEC Size 14x65/85mm Rated Without indicator Current I n Without indicator 77.5mm Without indicator 10/14mm Without indicator w/offset Tabs Mounting Clip DC [A] Article Number UL Article Number UL Article Number UL Article Number UL [W] [A 2 s] [A 2 s] Weight [kg / 1] 0.78 Units per Package IEC Part Numbers IEC - Contact SIBA for Data Sheets (Amp) (Amp) (Amp) (Amp) Power Loss Pre-arcing I 2 t Total I 2 t* Article Number Fuse Clips 10mm Page Article Number Fuse Clips 14mm PCB Screw Mounting 514 PCB PCB Screw Mounting Fuse Base Page

9 Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 E V DC 30kA (L/R=1ms) 1100V DC (UL) IEC Size 14x65/85mm Coefficients for Heavy Duty Applications a A2 B1 B2 Cf Time-Current Characteristics Virtual Pre-arcing time - [s] R.M.S. Prospective Current [A] DIN Rail Mounting Rated voltage; 1500V DC, 1000V AC Rated current; 32A Power acceptance; 6W Conductor; 0.7mm 2-25mm 2 (maximum) Insulating voltage(between fuse contacts & DIN rail); - Rated impulse current; - Construction, body & handle; - Degree of protection; - Maximum torque; 2.5N m Contacts; - Flammability - Operating temperature range; - Important: DO NOT OPEN UNDER LOAD! For Fuse 507

10 E Rated Voltage Rated Breaking Test Class [Un] Capacity Voltage gpv 1100V DC 30kA (L/R=1-3ms) 1100V DC (UL) Standard(s) UL 2579 IEC Size NH1XL Rated Current I n Without indicator With Top Indicator and Fitting for Power Microswitch [A] Article Number UL Article Number UL [W] Weight [kg / 1] 0.78 Units per Package 1 IEC Part Numbers ( Not UL) IEC - Contact SIBA for Data Sheets (Amp) (Amp) Fuse Base Loss Pre-arcing I 2 t Total I 2 DC [A 2 s] [A 2 s] Indicator / Fuse Size NH1XL 1 - Pole Fuse Base Article No Rated Voltage Rated Current Breaking Capacity Rated Power Acceptance Weight Units per [V DC ] [A] [ka] [W] [kg/1] Package External Wall Article No Partition Wall Article No. Insulating Contact Covers Article No E

11 E Rated Voltage [Un] 1100V DC Rated Breaking Test Class Capacity Voltage gpv 30kA (L/R=1-3ms) 1100V DC (UL) Standard(s) UL 2579 IEC Size NH1XL Coefficients for Heavy Duty Applications a A2 B1 B2 Cf Time-Current Characteristics Virtual Pre-arcing time - [s] R.M.S. Prospective Current [A] Article Number Grip Handle, Insertion/Removal Tool Page Article Number Microswitch - GL Standard Standard (Red Hammer) w/leather Sleeve Page 509 Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 E V DC 30kA (L/R=1-3ms) 1100V DC (UL) IEC New Product - Contact SIBA Size NH1XL Rated SQB1 NH2XL SQB2 SQB0 SQB1 SQB2 SQB3 Power Pre-arcing Total Current US Short Knife Blade US Short M8 M8 M10 M12 Loss I 2 t I 2 t* I n Article No Article No Article No Article No Article No Article No Article DC [A] [W] [A 2 s] [A 2 s] to 250A to 250A to 450A to 160A to 250A to 450A to 500A 509

12 E Rated Voltage Rated Breaking Test Class [Un] Capacity Voltage gpv 1100V DC 30kA (L/R=1-3ms) 1100V DC (UL) Standard(s) UL 2579 IEC Size NH3L & SQB2 Rated Current Without indicator With Top Indicator and Fitting for Without indicator With Top Indicator and Fitting for Power Loss Pre-arcing I n Microswitch DC [A] Article Number UL Article Number UL Article Number UL Article Number UL [W] [A 2 s] [A 2 s] NH3L SQB2 NH3L SQB Contact SIBA Weight [kg / 1] 0.78 Units per Package 1 IEC Part Numbers ( Not UL) IEC - Contact SIBA for Data Sheets (Amp) (Amp) Fuse Base I 2 t Total Dimensions in / mm I 2 t* / Indicator / A B C D E1 E2 F L 5.08 / / / / / / / / 215 Fuse Fuse Base Rated Rated Breaking Rated Power Weight Units External Wall Partition Wall Insulating Size Voltage Current Capacity Acceptance per Contact Covers NH3L Article No. [V DC ] [A] [ka] [W] [kg/1] Package Article No. Article No. Article No. 1 - Pole Fuse Bases for SQB Series V DC (UL Pending) E PV2 Fuse Base 3 (200A -450A, 600kcmil -4/0CU9Al) 510

13 E Rated Voltage [Un] 1100V DC Rated Breaking Test Class Capacity Voltage gpv 30kA (L/R=1-3ms) 1100V DC (UL) Standard(s) UL 2579 IEC Size NH3L & SQB2 Coefficients for Heavy Duty Applications a A2 B1 B2 Cf Time-Current Characteristics Virtual Pre-arcing time - [s] R.M.S. Prospective Current [A] Article Number Grip Handle, Insertion/Removal Tool Page Article Number Microswitch - GL Page Standard Standard (Red Hammer) w/leather Sleeve 511

14 Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 Pending 1500V DC 30kA (L/R=3ms) 1500V DC (UL) IEC New Product - Contact SIBA Rated Current I n [A] SQB3 NH1XL NH2XL NH3L SQB0 SQB2 SQB3 US Short Knife Blade Knife Blade Knife Blade US Short US Short US Short to 355A to 160A to 200A to 250A to 250A to 160A to 250A to 500A Contact SIBA for Data Sheets L- Series SQB 0/1/2/3 Fuse Bases for SQB Series V DC (UL Pending) SQB - Series E PV1 Fuse Base (35-200A, 3/0-10 CU9Al) PV2 Fuse Base (200A -450A, 600kcmil -4/0CU9Al) PV3 Fuse Base (200A -450A, 2x250kcmil -6CU9Al) PV4 Fuse Base (35A -450A, bus bar - 12mm stud) Grip Handle, Insertion/Removal Tool Page Article Number Standard w/leather Sleeve Microswitch - GL Standard (Red Hammer) Page

15 Rated Voltage Rated Breaking Test Class Standard(s) [Un] Capacity Voltage gpv UL 2579 Pending 1500V DC 30kA (L/R=3ms) 1500V DC (UL) IEC Rated Current 14mmx65m I n Article No [A] to 30A Contact SIBA for Data Sheets E Size NH00 - DIN80 Fuse Size NH00 DIN Pole Fuse Base Rated Fuse Bases Rated Breaking Rated Power Weight Units External Wall Partition Wall Insulating Voltage Current Capacity Acceptance per Contact Covers Article No. [V DC ] [A] [ka] [W] [kg/1] Package Article No. Article No. Article No Included N/A Dimensions [in / mm] / 126 A 4.96 / 126 B 1.57 / / 40 B / 34 B / 13 C 0.50 / / 19 D 0.75 / / 80 E 3.15 / / 3 F 0.12 / / 46 G 1.81 / 46 G1 G / 74 H 4.40 / / 6.5 I 0.26 / / 15.5 J 0.60 / / 16 K 0.63 / 16 Lmax 5.75 / / 146 L / 165 L2 M8 M M / 25 N 0.98 / 25 Max M8 nut torque 12N m 106lb in Max base mounting torque 4N m 35lb in

16 Article Number * Microswitches GL Microswitch Standard Level Insulating Change Interrupt Rating Voltage Over AC DC [V] Circuits [V] [A] [V] [A] 5(resistive) 33 3(resistive) (inductive) 26 3(inductive L/R =10ms) Weight [kg / 1] 0.02 Units per Package V AC 5V DC Interrupt Rating Minimum 30V AC 1mA(resistive) 30V DC Maximum 0.3A Fuse Clips for 10mm Diameter Contacts Dimensions [ in / mm] / 11.0 A 0.43 / / 12.0 B 0.47 / / 18.0 C 0.71 / / 3.6 D 0.14 / / 2.0 E E / 2.0 E / / 0.65 F 6.85 / / 11.0 G 0.43 / / 4.45 H 0.18 / / 1.5 I 0.06 / / 5.5 J 0.22 / / 11.5 L 0.45 /

17 Fuse Clips Fuse Clips for 10mm Diameter Contacts Dimensions [ in / mm] / 11.0 A 0.39 / / / 12.0 B 0.35 / / / 18.0 C 0.08 / / / 4.2 D 0.17 / 4.2 D 1 / M5 D 2 / M4 E 0.61 / / 0.65 F 0.43 / 11.0 G 0.22 / 5.5 H / 1.5 I 0.22 / 5.5 J 0.45 / 11.5 L Fuse Clips for 14mm Diameter Contacts Dimensions [ in / mm] / 15.5 A 0.39 / / 15.5 B 0.35 / / 22.8 C 0.08 / / 4.2 D 0.17 / / 0.7 F 0.06 / 1.5 I 0.26 / 6.5 J 0.57 / 14.5 L Dimensions [ in / mm] / 16.0 A 0.47 / 12.0 B 0.61 / 15.5 C 0.14 / 3.5 E / 5.0 E / 0.70 F 0.42 / 10.7 G 0.17 / 4.2 H 0.04 / 1.0 I 0.12 / 3.0 K 0.33 / 8.5 L

18 - Insertion / Removal Tool European NH Knife Blade Fuse System to 1600V AC NH1 - NH3 (a 5 =120mm - 124mm) (Standard) Do Not Operate Under Load! Do Not Operate Under Load! European NH Knife Blade Fuse System to 690V AC NH00 - NH (Standard) (with Leather Sleeve) (with Leather Sleeve) NH4 & 4a (with Leather Sleeve) Do Not Operate Under Load! 516

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:

More information

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4 URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4

More information

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic

More information

Ultra Rapid Fuses. For Semiconductor Protection

Ultra Rapid Fuses. For Semiconductor Protection UR Ultra Rapid Fuses For Semiconductor Protection Over many decades SIBA has developed a very comprehensive product line of Ultra Rapid fuses that has achieved worldwide acceptance. SIBA's worldwide distribution

More information

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM IEC High speed catalogue 10x38mm, PVM Series 600Vdc (UL), 4 to 30A A range of UL 2579 fast-acting 600Vdc midget fuse links specifically designed to protect solar power systems in extreme ambient temperature,

More information

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents HHM High Voltage Fuses Motor Circuit Protection DIN and British Standard SIBA Motor Rated Fuses are available in - German DIN Standard and - British Standard Design The large variety in body sizes / mounting

More information

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories ,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series Description: A range of XL package fuse links specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents

More information

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS 1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS

More information

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead , am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE SIBA Products are available from: MARYLAND METRICS phones: (410)358-3130 (800)638-1830 faxes: (410)358-3142 (800)872-9329 URL: http://mdmetric.com E-mail: sales@mdmetric.com P.O.Box 261 Owings Mills, MD

More information

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am

More information

NH HRC Fuses. IEC & British Standard Fuses NHG B

NH HRC Fuses. IEC & British Standard Fuses NHG B NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,

More information

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction. HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

fuse-links & fuse holders PHOTOVOLTAIC

fuse-links & fuse holders PHOTOVOLTAIC fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

Complete and reliable solar circuit protection

Complete and reliable solar circuit protection Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_

More information

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A Technical Data Effective March 0 Bussmann x38mm Photovoltaic fuses Operating class gpv and UL PV fuse links PV Fuse coordination With thin film cells and, 5 and crystalline silicon cells Description A

More information

Protistor size 70 gr 690VAC (IEC)

Protistor size 70 gr 690VAC (IEC) Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL) Protistor size 31 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according to IEC

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

General Purpose IEC Fuses

General Purpose IEC Fuses Line protection fuses gl-gg IEC 60269 parts1, 3 and 3-1 DIN VDE 0636 Parts 10, 30 and 31 Dimensions are stipulated in the following regulations: DIN 49360 D Fuse-links DIN 49515 D Fuse-links DIN 49367

More information

Semiconductor Fuses Microswitches & Studs

Semiconductor Fuses Microswitches & Studs MICROSWITCH SYSTEMS ADAPTED TO THE FOLLOWING FUSES: - PSC sizes 0,,, / 70, 7, 7, 7 - Blade-type PSC (PA) sizes 0-, - / 70, 7, 7, 7 - PSC sizes 000 / 00 New MS L -5 B6 MS PA -5 HIGHLY RESISTANT STUDS OFFERING

More information

Limitor -G General Purpose Fuses

Limitor -G General Purpose Fuses Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear

More information

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM NH SIBA NH Fuse-links with top and center indicator are available in a large variety of voltage ratings, body sizes and operating classes: Sizes: 000, 00, 0, 1, 2, 3 and 4 Voltage ratings: AC 400 / 500

More information

Utilisation category gl/gg 500VAC with combi indicator

Utilisation category gl/gg 500VAC with combi indicator DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions

More information

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection HHD-BPT Selection Guide HHD-BPT, DIN Style, Current-imiting,, Potential Transformer Protection Current ratings [A]; 0.5, 1, 2, 2.5, 3.15, 4, 5 E=192mm Page E=292mm Page E=367mm Page E=442mm Page E=537mm

More information

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL GREEN PROTECT DC - distribution and protection components Cylindrical fuse-links Fuse holders for cylindrical fuse-links Accessories for cylindrical fuses NH fuse -links NH fuse bases NH fuse disconnectors

More information

XL Photovoltaic fuse links

XL Photovoltaic fuse links Technical Data 020 Supersedes November 207 BUSSMANN SERIES Product description Eaton s Bussmann series XL fuse links are specifically designed to protect and isolate photovoltaic array combiners and disconnects.

More information

2013 JEAN MÜLLER Products

2013 JEAN MÜLLER Products 2013 JEAN MÜLLER Products Company JEAN MÜLLER JEAN MÜLLER was founded in 1897 in Germany, when the applications of electricity were still in their very early days. The company chose as its basic activity

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Solar circuit protection application guide. Complete and reliable solar circuit protection

Solar circuit protection application guide. Complete and reliable solar circuit protection Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

RS308-PV-3E Midget Fuse

RS308-PV-3E Midget Fuse RS308-PV-3E Series 1-25 1000V Midget Fuse SJ1038 Clip Conform to IEC60269 & UL2579 & GB13539 Rated Voltage: DC1000V (L/R=1~3ms), C1000V (COSΦ 0.5) Rated Current: 1~25 Protection: IEC gpv (General PV Protection)

More information

Panel-mounting components

Panel-mounting components Quality Panel-mounting components For conventional cabling, Wöhner offers a comprehensive range of panel components suitable for either plate or DIN-rail mounting. Fuses and the associated connection technology

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

Protistor size 120 gr 750VDC (IEC)

Protistor size 120 gr 750VDC (IEC) Protistor size 12 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS DC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination Very low I²t Extremely fast

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Bussmann series NH photovoltaic fuse links

Bussmann series NH photovoltaic fuse links Technical Data 72033 Supersedes April 204 Bussmann series NH photovoltaic fuse links BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

Bussmann series NH bases

Bussmann series NH bases Supersedes October 2013 BUSSMANN Product description Eaton s range has been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes with a accessories

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Bussmann NH Bases. Technical Data Effective October Product description: Standard features:

Bussmann NH Bases. Technical Data Effective October Product description: Standard features: Technical Data 10163 Bussmann NH Bases Product description: Bussmann s range of NH bases has been designed with thermoplastic bodies, DIN-Rail and/or screw mounting (size 4 screw mounting only). This range

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails One Source Insulator Clamps for devices Fuse monitoring for NH Fuse-Bases or Fuse-Rails Solid links MM: Bild angeben Content NH Replacement Handles 192 NH Solid-Links 192 Fuse-Monitoring with strikers

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

NH photovoltaic fuse links

NH photovoltaic fuse links Technical Data 72033 Supersedes January 207 BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed to protect and isolate photovoltaic array

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

G eneral Purpose Fuses

G eneral Purpose Fuses G eneral Purpose Fuses North American Power Fuses AMP-TRAP2000 AMP-TRAP2000 AJT Class J - Time Delay 1 to 600A - - Motor, motor controller, control transformer, and circuit back-up protection. Space saving

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Unimate Range Pitch 5.08

Unimate Range Pitch 5.08 itch 5.08 in headers Socket connectors CB connection Solder connection SLA 90 250 V / 17.5 A SLA 180 250 V / 17.5 A.2.3 Cable connection Clamping yoke connection TO clamp connection BLA 250 V / 17,5 A

More information

IEC and British Standard Fuses.

IEC and British Standard Fuses. IEC and British Standard Fuses Section Contents Page Application Data..................... 45-46 CSA Type P and Type D fuses (CDS, CDN & PON)............................47 Tron HRC Form II Class C fuses

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Gears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links.

Gears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links. -EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 69 V and VD. They are in compliance with IE 669, DIN VDE 66, part, and DIN 6 (dimensions). NH fuse bases are available for delivery

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks Technical Data 09 Effective June 06 Up to 60 A Class R 50 V and 600 V ferrule power distribution fuse blocks Catalog symbols: RM5060-_MW_ RM60030-_MW_ RM60060-_MW_ Features and benefits: Combination power

More information

NH DIN Dual Indication Fuse Links

NH DIN Dual Indication Fuse Links Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Powermate Range pitch 7.00 Powermate Range pitch 7.00

Powermate Range pitch 7.00 Powermate Range pitch 7.00 Contents lug and socket connectors with leaf spring connection.2 lug and socket connectors with TO connection.6.1 lug and socket connectors with leaf spring connection STVS S Derating curve STVS SB Socket

More information

NEOZED D0 fuse-links gg 400/440VAC

NEOZED D0 fuse-links gg 400/440VAC NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non

More information

Selector guide. PSC Square body fuses Size 3X VAC Blade Terminals. Features and Benefits

Selector guide. PSC Square body fuses Size 3X VAC Blade Terminals. Features and Benefits Selector guide PSC Square body fuses Size X 500 700C Blade Terminals October 201 Issue 1 The IXYS UK range of 700/690 protistor fuse links provides maximum flexibility in equipment design and ultimate

More information

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks Technical Data 1048 Class R 2V and 600V modular ferrule and Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole

More information

1500V. Now Available

1500V. Now Available 1500V Now Available Since 198, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

Bussmann series IEC cylindrical fuses

Bussmann series IEC cylindrical fuses IEC and ritish Standard fuses 5 Contents ussmann series IEC cylindrical fuses Complete portfolio of 8-22 mm diameter Class am and Class gg cylindrical fuses for industrial applications escription Fuses

More information