Circuit Breaker Modules

Size: px
Start display at page:

Download "Circuit Breaker Modules"

Transcription

1 he Ex d enclosure is made of unsaturated reinforced polyester, equipped with contacts for major terminals, auxiliary terminals and operating handle. An explosion-protected creep breaker module in the circuit, rated 34/0V and A, is used to protect from contact indirectly for persons and from over-current for the circuits of building, etc. t is also used to protect from fire caused by continuous existence of earthing fault because of an overcurrent protection devices without action. Accurate current trip setting Direction of inlet for power wire is random he module with padlock function est button is set outside creep breaker module Built-in Apparatus Modules: he electric components of international famous brand are selected to be mounted in our built-in explosion-proof electric apparatus module. he explosion-proof enclosure is made of unsaturated reinforced polyester. he enclosure is equipped with contracts for major terminals and auxiliary terminals and operation handle etc. t is mounted in the increased safety enclosure which the degree of protection is greater than P4 and many components can be used to satisfy the operation requirements of different circuits. he series products have been individually got the conformity certificate of explosion-proof, international certification, and have passed the relevant test for electric life. he material of flameproof electric box and flameproof instrument box is die-casting aluminum alloy, the surface is sprayed with epoxy resin powder. he different electric component can be mounted inside of electric box and can be used together with full plastic increased safety box body. t is fitted with normal measuring meter which can be observed through the transparent glass window of box cover

2 igh on-off miniature breaker module SPEFANS Ex mark: Ex de Ⅱ ( 0. ~ 1A ) Ex de Ⅱ ( 0 ~ A ) ntended use: an be used in zone 1 and zone ; zone 1 and zone Rated voltage: V / 0V;0 / 0z Rated current: 0. ~ A rip character: haracteristic curve apacity of auxiliary contact: A13 3A/0V A1 ross section of terminal: Major contact mm Auxiliary contact.mm A/0V Number of poles rip haracter Weight(kg) 1P P 3P 4P 1P+N 3P+N RDER SPEFANA BL high on-off miniature breaker module rder No.(ode) (1P) 1N-(1P+N) -(P) 3-(3P) 3N-(3P+N) 4-(4P) D BL / 0. / / - 0 BL / 1 / / - 0 BL / / / - 0 BL / 3 / / - 0 BL / 4 / / - 0 BL / / / - 0 BL / / / - 0 BL / 1 / / - 0 BL / 0 / / - 0 BL / / / - 0 BL / 3 / / - 0 BL / / / - 0 Number of poles rip haracter Auxiliary contact 1N + 1N ( No matching not noted ) characteristics curve: t is mostly used for illumination loop and part power loop. D characteristics curve: t is mostly used for power loop and other heavy inductance loop. --

3 igh on-off miniature breaker module ELERAL DAGRAMS 1 N N N P 1P+N P 3P 3P+N 4P 0 DMENSNS Dimension 1 Dimension Dimension 3 Dimension 4 Dimension 1 Dimension Dimension 3 Dimension 4 1P 1P+N P 1P + Number of poles Auxiliary contact 3P P + Auxiliary contact 3P + N 4P 3 P + Auxiliary contact 4P + Auxiliary contact -3-

4 reep age breaker module SPEFANS Ex mark: Ex de Ⅱ ( ~ 1A ); Ex de Ⅱ ( 0 ~ A ) ntended use: an be used in zone 1 and zone ; zone 1 and zone Rated voltage: V / 0z Rated current: ~ A Rated remained action current: 0mA rip character: haracteristic curve Number of poles: 1P + N ross section of terminal: Major contact mm Weight: 1.1 kg RDER SPEFANS BFL reep age breaker module with over current protection ( electromagnetic ) rder No.(ode) BFL / / 1N / BFL / / 1N / BFL / 1 / 1N / BFL / 0 / 1N / BFL / / 1N / BFL / 3 / 1N / BFL / / 1N / 0 Rated creep age current (ma) n BFL reep age breaker module with over current protection ( electronic ) rder No.(ode) BLD / / 1N / BLD / / 1N / BLD / 1 / 1N / BLD / 0 / 1N / BLD / / 1N / BLD / 3 / 1N / BLD / / 1N / 0 Rated creep age current (ma) n ELERAL DAGRAMS DMENSNS N N BFL Electromagnetic BLD Electronic 4 Dimension

5 reep age breaker module SPEFANS Ex mark: Ex de Ⅱ ntended use: an be used in zone 1 and zone ; zone 1 and zone Rated voltage: /0V; 0/0z Rated current: A A Rated remained action current: 0 0mA Number of poles: 4P ross section of terminal: Major contact mm Weight: 1.9 kg RDER SPEFANS BFL reep age breaker module with over current protection ( electromagnetic ) Rated current Rated creep age current rder No.(ode) BF / / 4 / BF / / 4 / 0 BF / / 4 / BF / / 4 / 0 BF / / 4 / 0 ELERAL DAGRAMS DMENSNS N N Dimension 4 --

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent

More information

11 Control Panels, Distribution Panels and Components

11 Control Panels, Distribution Panels and Components Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working

More information

Control Panels, Distribution Panels and Components

Control Panels, Distribution Panels and Components 11 Control Panels, Distribution Panels and Components EEx d Enclosures in Light Metal or stainless steel Flexible modular design for combining enclosures Can be used in Zone 1 and Zone 2 in Zone 21 and

More information

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS RCBOs - Residual current circuit breakers with integral overcurrent protection KZS Advantages of residual current circuit breakers with integral overcurrent protection KZS - 1M Combining the features of

More information

QUALITY ASSURANCE & DOCUMENTATION

QUALITY ASSURANCE & DOCUMENTATION QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Panelboards & Motor Starters

Panelboards & Motor Starters Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number

More information

Unused flameproof threads for cable glands have to be closed with certified plugs.

Unused flameproof threads for cable glands have to be closed with certified plugs. E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.

More information

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.

More information

BDZ52 Series Explosion Proof Circuit Breaker(ⅡB,ⅡC,DIP)

BDZ52 Series Explosion Proof Circuit Breaker(ⅡB,ⅡC,DIP) BDZ52 Series plosion Proof ircuit Breaker(ⅡB,Ⅱ,DIP) Application Designed for plosive atmosphere Zone, Zone 2 ombustible dust Zone 20, Zone 2, Zone 22 Designed for Groups ⅡA,ⅡB,Ⅱ Temperature classes T~T6/T5/T4

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - D D S T R B U T O N S with metal EJ enclosures for gases in explosion group B Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.

More information

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific) 4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Armoured / Un-armoured Cable Gland

Armoured / Un-armoured Cable Gland Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance

More information

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

Technical features Certifications

Technical features Certifications The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market, with

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary

More information

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Local Control Station

Local Control Station Local Control Station As per table given below Ex'd', IIC, IP-66, FLP/WP Local Control Station and Switch MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFRS/104/I/IIC-IEC MFRS/104/IIC-IEC A B C D

More information

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog) User s Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals by electronic

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement

More information

TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type)

TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type) TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type) Introduction Electrohydraulic-acting Spring-return rotary actuator 90

More information

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request. MVSI The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market,

More information

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08

SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08 Zone 1 21 22 2 SKX 16, 18, 20 IP 66 +50 C 20 Enclosures made of glassfibre reinforced polyester resin or stainless steel AISI 316L 3 basic enclosure sizes in GRP 3 basic enclosure sizes in stainless steel

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Internationally approved.

Internationally approved. E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure

More information

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE A BREAKER PROTECTION BREAKTHROUGH Simplify flameproof protection for lighting, heat trace and power circuit distribution with the new generation

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01 MJH Model Power Voltages MJH Up to 12.500 kva Up to 15.000 V Frame 400 ± 1.250 Pole 4, 6, 8 Cooling IC 01 (over contact MM) IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with filters.

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected switchgear CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können GHG 981 Ex-Safety switch for zone 22 GRP, Stainless steel, and painted steel enclosures for harsh environments

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Junction box for EKL light

Junction box for EKL light M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven

More information

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01 MJB Model Power Voltages MJB Up to 6.500 kva Up to 1.000 V Frame 160 ± 900 Pole 4, 6, 8, 10 and 12 Cooling IC 01 (over contact MM) IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with

More information

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01 MJB Model Power Voltages MJB Up to 6.500 kva Up to 1.000 V Frame 160 ± 900 Pole 4, 6, 8, 10 and 12 Cooling IC 01 (over contact MM) IP Enclosure Main Applications Sector IP 23. Available up to IP 44 with

More information

LIMIT SWITCH BOX MODEL - APL

LIMIT SWITCH BOX MODEL - APL FEATURES AND BENEFITS Enclosure -Solid design, aluminium die-casting IP67 Painting-Powder coating Housing Body- Aluminium die-casting Quick-set Cam-Easy to set, Splined cam Open Yellow, Close Red Various

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

Ex UPS standard Series 8265

Ex UPS standard Series 8265 > Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of

More information

Series Level-Trol Electronic Liquid Level Transmitters

Series Level-Trol Electronic Liquid Level Transmitters 0- Level-Trol Series 0- Series Level-Trol Electronic Liquid Level Transmitters W0-/IL Non-Interactive Zero and Span Adjustments; Dry Span Calibration Allows Field Recalibration without Removing Wiring

More information

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8549 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. O.: C3700-L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3700-L 298-29, GODA-RO, GUPO-SI, GYEOGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:

More information

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom Annex to IECEx Certificate of Conformity Equipment Range: The design variants covered are either: a) Complete

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

D Series Ex d Stainless Steel

D Series Ex d Stainless Steel 2 Way irect Acting Solenoid Valve IIC T4/T6 Series Stainless Steel 2 and 3 Way irect Acting Solenoid Valve IIC T4/T6 2SK-CM [ FEATURES ] Integral terminal box with coil housing. Valve do not require minimum

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

Limit Switch Type 4747

Limit Switch Type 4747 Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical

More information

Industrial Variable Speed A-C Motors B-4511

Industrial Variable Speed A-C Motors B-4511 Industrial Variable Speed A-C Motors The Reliance is an integrated motor and control product offering power matched variable speed performance in a single package. Applications Material Handling. Fluid

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

I-BRICK. High quality LED from Samsung. Curve shaped design. Vandal proof protective cover. Visual comfort. Available in 2 sizes.

I-BRICK. High quality LED from Samsung. Curve shaped design. Vandal proof protective cover. Visual comfort. Available in 2 sizes. I-BRICK is a range of wall recessed luminaires with LED and compact fluorescent light sources. The glare-free cover enables I-BRICK to be installed in most places where a comfortable illumination is needed.

More information

CRANE Limit Switches. CCR Series. CXA Series. CCA Series

CRANE Limit Switches. CCR Series. CXA Series. CCA Series CCR Series CXA Series CCA Series CCR Series - Economical General Purpose CRANE Limit Switches The CCR Series Limit Switch provides a compact design and the most economical solution for both visual and

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Lighting series JSNEVW Lighting series JLEDW LEUCHTEN 2011/09

Lighting series JSNEVW Lighting series JLEDW LEUCHTEN 2011/09 W A R N I N G L I G H T S Lighting series JSNEVW Lighting series JLEDW 2011/09 W ARNING LIGHTS Description of lighting: JUNG warning lights are sheet steel light fittings of protection type IP 65 and are

More information

JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR

JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR SV Series SOLENOID VALVE FEATURES - Can work without oil. - Life is long that can work more than ten million times under the condition of laboratory.

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work GE Industrial Solutions New Quitra 4000ED.02 Low Voltage Distribution oards up to 4000 GE imagination at work Quitra 4000 Quitra 4000 is a range of sheet steel system enclosures, delivered as a flat kit:

More information