1 Airmatic Lubricator Pneumatic Operation, Oil General The Airmatic lubricator is a simple economical unit with a broad range of output. It is designed to be operated with shop air. The stroke setting is easily adjusted to suit a wide variety of industrial centralized lubrication needs. The package can be supplied with either a, 4 or liter reservoir. Application The Airmatic lubricator is for use with cyclic oil lubrication systems. The unit can be used with single line resistance (SLR), positive displacement injector (PDI), progressive distribution and injector systems.* Operation Airmatic lubricator includes an air actuated, spring return piston pump with an adjustable output between to 0cc for each piston stroke at discharge pressures up to 500 psi. Oil output is related to piston travel and cycles per unit time. Stroke movement is preset to a fixed discharge and supply air pressure governs the output delivery pressure. When used with positive displacement injectors, a built-in pressure relief device lets the PDI reset after discharge. For extended service, incoming air must be dry. Always use a suitable FRL unit (filter/regulator/ lubricator) to control air to recommended operating range. Normally, the air-operated Airmatic is used with a 3/-way electrical solenoid valve (optional) to control and vent shop air from the pump air inlet. All models are available with optional 3/-way valve. *Refer to appropriate engineering manuals for normal system limitations when sizing distribution proportioning devices for use at a particular discharge setting. Delivery Adjusting Screw Oil Filler Cap Cap Outlet Discharge Settings Air Inlet Lock Nut To adjust lubricant delivery, loosen locknut on hex socket adjusting screw (see Figure on right). Turn delivery adjusting screw clockwise to reduse discharge use graduated label as guide, set to desired setting and tighten locknut (insert shows setting at 8cc). For PDI systems, maximum discharge of 0cc/stroke is recommended. Technical Data Delivery Volume Viscosity Range SSU cc-0cc/actuation cycle (infinite adjustment) Normal Range Cycle Up to 30 cycles/minute maximum Operating Temperature Oil Outlet Connection Low Level Switch Solenoid Valve Lubricator Air Connection (without solenoid) Operating Pressure Recommended Incoming Air Pressure Air/oil Pressure Ratio :4 Maximum Inlet Pressure Minimum Inlet Pressure 3 F to 0 F (0 C to 49 C) /8 NPTF (female) 0.7 amp at 0 VAC 0. amp at 0 VAC /4 NPTF (female) 300 psi ( bar) SLR & PRG 400 psi (8 bar) PDI & INJ 80 psi (5 bar) SLR & PRG 00 psi (7 bar) PDI & INJ 5 psi 70 psi Viscosity range at operating temperature may be restricted by internal relief valve (consult Bijur Delimon). System parameters may affect this rate (consult Bijur Delimon). Figure : Lubricant Delivery Adjustment
2 System Design If the distribution system incorporates extensive use of flexible lines, a slightly larger discharge must be used to compensate for the resiliency of the flexible connections. Solve for the following R value and ADD this amount to the required pump discharge: + + R =.030 x feet of 5/6 O.D. flexible hose + + R =.035 x feet of 7/6 O.D. flexible hose How to Order AIR Reservoir Capacity liter plastic reservoir 4 4 liter plastic reservoir liter metal reservoir Output Mode (System Type) A SLR (single line resistance) B PDI (positive displacement injector) C Progressive (sequential movement) D Injector Level Switch A Without level switch B With level switch Solenoid Valve A No solenoid B 0V solenoid C 0V solenoid F 0V solenoid, with DIN connector G 0V solenoid, with DIN connector H 4VDC solenoid J VDC solenoid K 4VDC solenoid, with DIN connector Example: liter unit for SLR system without switch and solenoid, use Part #AIRAAA. liter unit for SLR system without switch and solenoid, use Part #AIRAAA. *NOTE: System type D is for type ZEE injectors Several options are available in this configuration. It is necessary to choose the proper prefix letters for the particular type of unit required. Designation of lubricator is AIR, followed by a four part code, specifying reservoir size and pump options required. After the letters AIR, insert code for reservoir capacity. The third letter designation identifies the lubricator to be used for output mode (system type). Select the correct designation for lubricator unit to service the appropriate distribution system. Specify whether a low oil level switch is required by designating appropriate letter code in the fourth letter designation. Solenoid valve selection is last designation. If required, select prefix for solenoid valve by voltage.
3 Service Parts- Liter Model Item Part # Description B08- Cap B897 Gasket 3 HF705C Cap Strainer 5 D38 Reservoir assembly 6 B Level switch (closes at low level) Retainer Nut (4x) 9 A384 Support (*) 0 A3848 Screen (*) A3899 Ring (*) A3843 Clamp (*) 3 B3907 Check valve 4 B6086 Adapter Tubing Tubing assembly Valve assembly** Solenoid valve 0 VAC 03- Solenoid valve 0 VAC 03-3 Solenoid valve 0 VAC w/din conn Solenoid valve 0 VAC w/din conn Solenoid valve 4 VDC 03-6 Solenoid valve VDC 03-7 Solenoid valve 4 VDC w/din Conn 9 A439-M Muffler filter * = Available in Kit #A SEE VIEW A OR B VIEW A SLR & PROGRESSIVE MODELS VIEW B PDI MODELS & INJ MODELS 6 45 **For Injector System, this item is replaced by P/N A409 7 VIEW C SOLENOID VALVE 8 9 SHOWN WITH DIN CONNECTOR 3
4 Service Parts- 4 Liter Model Item Part # Description KIT 3 B08- Cover 4 HF705C Cap Strainer 6 A384 Support (*) 7 A3848 Screen (*) 8 A3899 Ring (*) 9 A3843 Clamp (*) 0 B3907 Check Valve Reservoir assembly (Reservoir, gasket, & screws) 0736 Quick dump valve assembly** 03- Solenoid valve 0 VAC 03- Solenoid valve 0 VAC 03-3 Solenoid valve 0 VAC w/din conn Solenoid valve 0 VAC w/din conn Solenoid valve 4 VDC 03-6 Solenoid valve VDC 03-7 Solenoid valve 4 VDC w/din conn. 3 A439-M Muffler filter 4 B Low Level Switch * = Available in Kit #A093 = See note on reservoir 4 SEE VIEW C VIEW A SLR & PROGRESSIVE MODELS 0 VIEW B PDI MODELS & INJ MODELS SEE VIEW A OR B RESERVOIR NOTE: 4 Liter Airmatic Pumps with a date code previous to VW used mounting screw design reservoir; Reservoir p.n. D3845/Gasket B0670 New design is a 4 mounting screw reservoir; p.n KIT as shown in the service part list to the left. SEE VIEW A OR B **For Injector System, this item is replaced by P/N A409 VIEW C SOLENOID VALVE 3 SHOWN WITH DIN CONNECTOR 4
5 Service Parts- Liter Model Item Part # Description B984 Filler cap 766 Strainer 3 B08- Cover 4 93 Sight gauge 5 B960 Plug 6 H043 O-ring Reservoir 8 A384 Support (*) 9 A3848 Screen (*) 0 A3899 Ring (*) A3843 Clamp (*) B3907 Check valve Quick dump valve assembly** Solenoid valve 0 VAC 03- Solenoid valve 0 VAC 03-3 Solenoid valve 0 VAC w/din conn Solenoid valve 0 VAC w/din conn Solenoid valve 4 VDC 03-6 Solenoid valve VDC 03-7 Solenoid valve 4 VDC w/din conn. 5 A439-M Muffler filter Low Level Switch * = Available in Kit #A SEE VIEW A OR B VIEW A SLR & PROGRESSIVE MODELS VIEW B PDI MODELS & INJ MODELS VIEW C SOLENOID VALVE 5 3 **For Injector System, this item is replaced by P/N A409 5 SHOWN w/ DIN CONNECTOR 4
6 Dimensional Schematics Liter Model (PDI Version Shown) Measurements shown in inches /8 NPTF OIL OUTLET 4.83 CONDUIT CONNECTION FOR OPTIONAL LOW LEVEL SWITCH 5.75 Ø.3 THRU STROKE ADJUSTMENT: REMOVE PROTECTIVE CAP, LOOSEN LOCKNUT, TURN SCREW IN TO DECREASE PUMP OUTPUT PER STROKE, BACK SCREW OUT TO INCREASE. PUMP IS AT FULL STROKE WHEN DIMENSION A EQUALS INCH, USE 5/3 ALLEN WRENCH Stroke Adjustment Settings A 5.0cc 3.0cc.0cc Airmatic Bijur Lubr.9 MAX LUBRICATING SYSTEMS 7.08 For service call: USA EUROPE MIN 45 6
7 Dimensional Schematics 4 Liter Model Measurements shown in inches. 7
8 Dimensional Schematics Measurements shown in inches. Liter Model SOLENOID VALVE INCLUDED ONLY WITH MODELS AIRXXB, THRU AIRXXK (INCLUSIVE) AIR SUPPLY CONNECTION /8 NPT (W/ S. V.) OIL DISCHARGE ADJUSTMENT (PER CYCLE) ELECTRICAL POWER SUPPLY / NPS CONDUIT CONNECTION AIR SUPPLY CONNECTION /4 NPT (W/O S. V.) (ALTERNATE CONNECTION) WAY SOLENOID VALVE. AIR EXHAUST CONDUIT CONNECTION / NPS THREAD 4X /8 NPTF OIL DISCHARGE CONNECTION DRAIN PLUG /8 NPTF OIL DISCHARGE CONNECTION LEVEL SWITCH & JUNCTION BOX INCLUDED ONLY WITH MODELS AIRXBX
Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data
Airmatic Lubricator Pneumatic Operation, Oil General The Airmatic lubricator is a simple economical unit with a broad range of output. It is designed to be operated with shop air. The stroke setting is
More informationFill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer)
GPO ubricator Motor-driven gear pump, Oil General The GPO ubricator is a motor-driven gear pump that is designed for use with single line centralized lubricating systems utilizing progressive distributors
More informationSureFire II Lubricator
SureFire II Lubricator Automatic, Oil & Fluid Grease, Three Phase General The SureFire II Lubricator is an automatic, robust and durable pump. Its compact size is designed to fit your space requirements
More informationUse Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.
V5W Lubricator Automatic Continuous Operation The V5W Lubricator consists of a motor-driven gear pump, with a controlled bypass valve. (constant volume or constant pressure models) The fully automatic
More informationSureFire II Lubricator
SureFire II Lubricator Automatic, Oil & Fluid Grease, Single Phase General The SureFire II Lubricator is an automatic, robust and durable pump. Its compact size is designed to fit your space requirements
More information3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port.
MultiPort Lubricator Grease, Injector General The MultiPort Lubricator is an electrically driven multiple outlet lubrication unit design primarily for use with injector systems. The unit includes two pumping
More informationMultiPort II Lubricator
MultiPort II Lubricator Mobile, PDI, Grease General The MultiPort II Lubricator is an electrically driven multiple outlet lubrication unit designed primarily for use with positive displacement injector(pdi)
More informationOil Streak Air-Oil Generating Unit
Oil Streak Air-Oil Generating Unit GENERAL The Air-Oil Generating system delivers high efficiency lubrication for high-speed spindles and other applications requiring accurate oil deliveries, in combination
More informationZEM Injector. Series 32, 33, 34, 35, 39. General. Operation. Features. Technical Data. Injector Outputs R2 08/10
ZEM Series 32, 33, 34, 35, 39 General The ZEM Series injector line are positive displacement injectors (PDI) that deliver precise and controlled lubrication outputs which meet exact requirements for diverse
More informationOperators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3
Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) 36412 r#3 Contents Precautions & Symbols...2 Manufacturer s Statement...2 General...2 Features...2 Operation...3-4 Technical
More informationCXL2 Injectors & Manifolds
CXL2 Injectors & Manifolds Premium Single Line Grease Systems General Designed for use in single line high pressure automatic grease systems, CXL2 Injectors deliver precise volumes of lubricant at predetermined
More informationMultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17
MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed or adjustable output pumping elements to
More informationMultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09
MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed output pumping elements to discharge grease
More informationMOTOR. The electric motor. DC - direct current voltage.
TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily
More informationMultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18
MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed or adjustable output pumping elements to
More informationLubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems
LubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems The Choice of Lubrication Professionals. As a hard-working professional focused on ensuring your production lines keep moving
More informationM OTO R. The electric motor. DC - direct current voltage.
TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily
More informationAutomatic SingleLine Greasing System
Parts Manual Automatic SingleLine Greasing System D000144R04 YOUR EFFICIENCY IS OUR CHALLENGE All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying,
More informationMultiPort II Lubricator
MultiPort II Lubricator Mobile, Progressive, Grease General The MultiPort II Lubricator is an electrically driven multiple outlet lubrication unit designed primarily for use with progressive divider valve
More informationOPERATOR S MANUAL AND SALES AND ENGINEERING DATA
OPERATOR S MANUAL AND SALES AND ENGINEERING DATA INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING. INCLUDE MANUALS: AF044X-XX Air Motor (pn 97999-1466) & S-632 General
More informationGrease and Oil Injectors
Grease and Oil Injectors LIT099 AL-32 Grease Injector OVERVIEW The AL-32 Grease Injectors are designed for single line, high-pressure centralized lubrication systems. These injectors are available in
More informationBijur Delimon Lubrication Equipment
New range Bijur Delimon NOW IN STOCK Lubrication Equipment Minimise downtime and maximise production with Bijur Delimon s range of highly reliable lubrication products and components. Pumps Distribution
More informationFZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09
FZ- Lubricator Electric, Oil & Grease General The FZ- Lubricator is primarily designed for direct feed applications for servicing up to 12 lubrication points. The lubricators are supplied with pump bodies
More informationAIR-OIL injector BLOCK. Oil Streak Generating, Mixing and PDI systems
AIR-OIL injector BLOCK Oil Streak Generating, Mixing and PDI systems General The Air-Oil Injector Block Assembly is available with one to eight Positive Displacement Injectors(PDI). Each outlet has an
More informationSeries 3000 Divider Valve Manifold
Series 3000 Divider Valve Manifold Progressive Systems General The Series 3000 progressive divider valve manifold distributes and proportions incoming oil or grease to bearing points. A typical divider
More informationSection 9: Centralized Lubrication Systems
ALEMITE LUBRICATION EQUIPMENT AND FLUID HANDLING PRODUCTS Oil Mist Systems Introduction Alemite Oil Mist Systems are used to service all types of machine elements that require continuous lubrication, such
More informationYour machinery deserves genuine Bijur parts.
Your machinery deserves genuine Bijur parts. For over 80 years, Bijur has manufactured and supplied the best parts and components for lubrication applications. With over 10,000 parts, you know we have
More informationAIR HYDRAULIC PUMP SIDE VIEW
Parts List for: form No. 101260 PA462 PA464 PA464-5R AIR HYDRAULIC PUMP SIDE VIEW 7 Basic Pump Ass'y See sheet 2 of 4. 1 6 5 2 4 Item Part No. Item Part No. No. No. Req d Description No. No. Req d Description
More informationLOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS
Directional Control Valves LOAD SENSE SECTIONS NEED NEW PIC Series 20 STANDARD FEATURES Control and reduced Dead Band (20I) and Tie Rod Kits SPECIFICATIONS Pressure Rating Foot Mounting Maximum Operating
More informationELECTRIC HYDRAULIC PUMP
Parts List for: Form No. 1000048 PE55TWP PE55TWP-220 MODEL D ELECTRIC HYDRAULIC PUMP Maximum Capacity: 10,000 PSI See Back Sheet 5 of 8 1 13 2,3 11 OFF ON WARNING 6 4,5 0IL 7 VALVE DETAIL TORQUE SPOOL
More informationLow Profile J Series Power Unit with Vane Pump
Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING
More informationEP Series Electro-Pneumatic Preset Valve
EP Series Electro-Pneumatic Preset Valve Installation and Parts L I Q UID C O N T R O L S An IDEX Energy & Fuels Business LC_IOM_EPVALVE: V3: 03/17 PUBLICATION UPDATES AND TRANSLATIONS The most current
More informationDESCRIPTION OPERATION. Product descripption SureFire Electrical Pump
Product descripption SureFire Electrical Pump DESCRIPTION The SureFire centralised lubrication system is robust and durable, capable of handling oil and fluid greases. Available in four reservoir capacities
More informationForm No Parts List for: MODEL B ELECTRIC HYDRAULIC PUMP. Maximum Capacity: 10,000 PSI PE55TWP-IBT-115. Sheet No. 1 of 8
Parts List for: Form No. 1000457 PE55TWP-IBT-115 MODEL B ELECTRIC HYDRAULIC PUMP Maximum Capacity: 10,000 PSI 1 2 3 7 SPX Hydraulic Technologies, Rockford, IL 61109 USA www.powerteam.com Made in USA 309219Rev7
More informationModular Lube Lubrication Systems
Modular Pump Accessories Low-Level Switches Low-level switches for modular design reservoirs. Use with Reservoir # Switch Type Electrical Rating 84235 87417, 87418, 87419 SPDT 84250 87400 SPDT 7 Amps 125
More informationForm No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI
Form No. 101249 Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP Max. Capacity: 10,000 PSI Air Motor Assembly See sheet 3 of 6 13 12 1 11 10 8, 9 Basic Pump Assembly See sheet 4 of 6
More informationForm No CE Parts List for:
Form No. 1000048CE Parts List for: PE55TWP-E110 PE55TWP-E220 MODEL B ELECTRIC HYDRAULIC PUMP Maximum Capacity: 10,000 PSI 8 9 TORQUE SPOOL 110-120 IN. LBS. TORQUE NUT 15-20 IN. LBS. 5 3,4 1,2 VALVE DETAIL
More informationsurefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) 35027E R
surefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) Index General...2 Application......................................................... 2 Safety..............................................................
More informationK & KRM-Series Liftgate Terminology
K & KRM Series K & KRM Series Click the appropriate link below for the major component of the liftgate for which you are trying to find the correct part. If you are unsure of the name of the part in Waltco
More informationCatalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.
More informationISO 5599/ Series Technical and Operating Data
ISO 5599/ Series...................................................................3-9 Technical and Operating Data......................................................................3- How to Order...................................................................................5-6
More informationHYDROSTATIC TEST SYSTEM MANUAL
PDQC HYDROSTATIC TEST SYSTEM MANUAL Technical Specification Operating Instructions Part List Revised 12-2016 Manual # PDQC- 6,000 And PDQC-10,000 1 PDQC PERFORMANCE DATA Model Number Maximum Pressure Volume
More informationLubePro Series Pumps. For Simple, Injector-Based Automatic Lubrication Systems. The Choice of Lubrication Professionals
LubePro Series Pumps For Simple, Injector-Based Automatic Lubrication Systems The Choice of Lubrication Professionals As a hard-working professional focused on ensuring your production lines keep moving
More informationIndustrial Lubrication Pumps Hose Reels and Accessories
Industrial Lubrication Pumps Hose Reels and Accessories Grease Control Handle with Digital Meter Hose Reels Oil and Grease Barrel Pumps Trucks, Dollies, Bases Manual Pumps Standard Duty Oil Transfer Pumps
More informationLogSplitterPlans.Com
Hydraulic Pump Basics LogSplitterPlans.Com Hydraulic Pump Purpose : Provide the Flow needed to transmit power from a prime mover to a hydraulic actuator. Hydraulic Pump Basics Types of Hydraulic Pumps
More informationInstallation. Installation. 12. System Diagram... 10
Pressure Control Systems Installation Instructions Form No. F-1031 Section 3010 Issue Date 08/20/96 Rev. Date 9/11/17 Table of Contents Discharge Relief Valve System System Description....................................
More informationSPRAGUE PRODUCTS AIR DRIVEN HYDRAULIC PUMPS
SPRAGUE PRODUCTS AIR DRIVEN HYDRAULIC PUMPS A variety of hydraulic pumps is offered for various liquid output pressure up to 33,500 psi (2311 bar). Sprague Products pumps service water, oil and most corrosive
More informationENGINEERING DATA. Quick Reference Chart. Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted. Industrial Hydraulics
ENGINEERING DATA Industrial Hydraulics Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted SYMBOL Quick Reference Chart GPM @ MAXIMUM PRESSURE THEORETICAL INPUT HP MODEL 100 PSI &
More information2.3 MEDIUM HEAVY DUTY SERIES
2 2.3 MEDIUM HEAVY DUTY SERIES CONTENTS PPV11 Ordering Code 2.3.1 Medium Heavy Duty Series 2.3.2 Torque limiter settings Technical Information 2.3.3 Specifications 2.3.4 Hydraulic fluids 2.3.5 Viscosity
More informationINSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C
INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C This additive injection system was designed to be used with five gallon jug of additive. The system is supplied
More informationSUREFIRE SLR. Centralized Lubricating System. + SureFire SLR Automatic Lubricator + Resistance Fittings + Distribution Components + Accessories
SUREFIRE SLR Centralized Lubricating System + SureFire SLR Automatic Lubricator + Resistance Fittings + Distribution Components + Accessories Contents Protect Expensive Machinery... 3 SureFire SLR Lubricator...
More informationVickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691
Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................
More informationForm No , 3 4, 5 VALVE DETAIL DIVISION UNEX CORPORATION. Parts List for: HYTORC-115 HYTORC-230 HYTORC MODEL D ELECTRIC HYDRAULIC PUMP
> Parts List for: Form No. 105548 DIVISION UNEX CORPORATION 333 STATE ROUTE 17 NORTH MAHWAH, N.J. 07430-9895 Tel: (201) 512-9500 Fax: (201) 512-0530 HYTORC-115 HYTORC-230 HYTORC-230-2 MODEL D ELECTRIC
More informationHand Operated Hydraulic Pumps PHP121DAH65 PHP121DA95. Engineering & Manufacturing Solutions
Engineering & Manufacturing Solutions HP Specifications: Volume Displacement HP22SA 0.20 in3 (3.3 cm3) (When handle is pulled). HP61DA 0.60 in3 (9.8 cm3) per full cycle. HP121DA 1.20 in3 (19.7 cm3) per
More informationPressure Control Valves Series R. General Description. Specifications. Flow Data
Catalog Y14-2502/US Technical Information Series R General Description Series R direct relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. Specifications
More informationPVE 19 & 21 Piston Pumps
Engineering PVE 19 & 21 Piston Pumps Pressures to 3500 psi For Mobile and Industrial Use Same Day Shipments Rated for 2400 rpm > Speeds to 2400 rpm www.fluidynefp.com Table of Contents Introduction...2
More informationThe TR-Series are large volume,
HYDROSTATIC TEST PUMPS Model TR-Series U p to 5.5GPM 5000PSI HYDRO INC. 3500 Arrowhead Drive Carson City Nevada 89706 web site: www.ricehydro.com e-mail: ricehydro@ricehydro.com Phone: (775) 885-1280 Fax:
More informationProduct description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES
Product description Electric Lubrication pump Dynamis Maxx APPLICATION The DYNAMIS MAXX pump was designed and developed to serve as a multi-function automatic lubricant pump. Due to its compact size and
More informationCentro-Matic. Automated Lubrication Systems
Centro-Matic Automated Lubrication Systems I install Lincoln Centro-Matic systems with confidence because I know they re going to prolong the life of my customer s critical machinery. Les Maness, Installation
More informationElectronic Proportional (EP) Control for Medium Duty Piston Pumps
Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps EP Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction........................................................................
More informationA system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.
Air/Oil Systems: A lubrication system in which small measured quantities of oil are introduced into an air/oil mixing device which is connected to a lube line that terminates at a bearing, or other lubrication
More informationTech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP
SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More informationThe EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER
FH Series The FH-series line of fire hose testers, offers testing pressures up to 1,000 PSI, with flow rates up to 10 GPM. Gas, Electric, and Diesel driven models, designed to safely test fire hose up
More informationOperating Instructions & Parts Manual
Operating Instructions & Parts Manual Grainger Part No. 36NE08 Bucher Hydraulics Part No. M-3504-0239 Please read the instructions carefully and always operate this equipment in a safe manner. Unit Description:
More informationCASH VALVE B SERIES PRESSURE REGULATORS
Single seated, spring loaded, direct acting diaphragm-type pressure reducing and regulating valves for a broad range of services FEATURES Reduce high inlet pressures to lower outlet pressures within close
More informationTrack Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel
Section 7.1 Track Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Track Drive Circuit: General...
More informationValve Lash and Valve Bridge Adjustment
Valve Lash and Valve Bridge Adjustment Illustration 1 g00286271 (1) 147-2060 Wrench (2) 147-2059 Torque Wrench (3) 148-7211 Bridge Nut Socket (4) 145-5191 Gauge Support (5) 147-2056 Dial Indicator (6)
More informationSEFC FLOW CONTROL INSTALLATION & USER GUIDE
SPECIFICATIONS: 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Pt size #12SAE (1-1/16 12). 10-Micron Filtration Recommended. Response Time 0.035 Standard dash pot (375 ms). 0.020 Dash
More informationAppendix D Outline Dimensions
Appendix D Outline Dimensions Models 91 691 and F91 F691 Bare with Flywheel L L1 M M1 M M1 L L1 Outline Dimensions Inches (Centimeters) Model A B C D E F G H J K 91, F91 1-13/16 2-3/8 3-11/16 13/32 5/8
More informationOperating maximum : 45 bars (650 psi) Operating minimum : 15 bars (220 psi) Relieving 0.7bars (11psi)
Product description ZEM Injector DESCRIPTION The ZEM Series injectors are positive displacement injectors (PDIs) that deliver precise and controlled lubrication outputs, meeting the exact requirements
More informationVersa II SLR Lubricator
Versa II SLR Lubricator With Controller General The Versa II SLR Lubricator is an automatic, robust and durable pump that can handle oil. Its compact size is designed to fit your space requirements and
More informationOPERATION & MAINTENANCE INSTRUCTIONS MODEL: TC-300
1-800-223-4540 ** 602-437-5020 OPERATION & MAINTENANCE INSTRUCTIONS MODEL: TC-300 READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING MACHINE Contents Safety Instructions Pg 3 Operating Instructions Pg 4-5 (Light
More informationOperators Manual ECO-AIR-IVS Internal Valve Actuation System
2534-A Shell Road Georgetown, TX 78628 www.parafour.com 512-626-4099 Operators Manual ECO-AIR-IVS Internal Valve Actuation System Ver 1.0 Warnings:!! This device is electrically operated and should only
More informationWALKIE HIGH LIFT HYDRAULIC SYSTEM
WALKIE HIGH LIFT HYDRAULIC SYSTEM W30-40ZA [B453]; W20-30ZR [B455]; W25-30-40ZC [B454] PART NO. 1524251 2000 SRM 1025 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure
More informationElectronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33
Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33 Model 39 Model 46 Model 54 Model 64 EP Control for Heavy Duty Series 2 Piston Pumps Table of Contents Introduction........................................................................
More informationAppendix A. Standard Symbols for Hydraulic Components
Table B.1 Flow lines Appendix A Standard Symbols for Components Continuous flow E Pilot connection L L>10E E Drain connection L L
More informationPneumatic Chemical Metering Pump
Timberline s was designed with the well pumper and the chemical man in mind. Each pump has a simple but rugged design that can be repaired in the field within minutes on the tailgate of a pickup truck.
More informationControl Reliable Double Valves with Total Dynamic Monitoring & Complete Memory
Control Reliable Double Valves Safety Exhaust (Dump) DM Series D Self Monitored - Clutch/rake Control asic Size,,, and 0 Dynamic Monitoring With Complete Memory: Memory, monitoring, and air flow control
More informationMODEL B ELECTRIC HYDRAULIC PUMP
Parts List for: Form No. 05 STATE RTE. 7 NORTH MAHWAH, NJ 070-995 Tel: (0) 5-9500 Fax: (0) 5-95 HYTORCQAS-C5 HYTORCQAS-C0 MODEL B ELECTRIC HYDRAULIC PUMP, 5 9 7 5, Motor Control Assemblies See sheets 5
More informationSection 8. Parts A Issued 7/00. Manual V -MA -01 (formerly 7-505/6V -MA -01) E 2000 Nordson Corporation All rights reserved
Section 8 E 000 Nordson Corporation 00 497A Manual 47-506V -MA -0 (formerly 7-505/6V -MA -0) 8-0 Manual 47-506V -MA -0 (formerly 7-505/6V -MA -0) 00 497A E 000 Nordson Corporation 8- Section 8. Introduction
More informationService and Parts Manual. Minimum Filtration Required:
R GRESEN Hydraulics Model V0 Sectional Body Directional Control Valve Service and Parts Manual Maximum Operating Pressure: Minimum Filtration Required: 00 PSI ( bar) 0 Micron The information in this Service
More informationThe EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER
FH Series The FH-series line of fire hose testers, offers testing pressures up to 1,000 PSI, with flow rates up to 10 GPM. Gas, Electric, and Diesel driven models, designed to safely test fire hose up
More informationI-BFV.KIT Butterfly Valve Gear Operator Replacement
SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before
More informationAccessories Index. Air Starters. Accessories Index By Description Accessory IR Page Description Part # Number J 1 SRV125 SRV125T SRV100
Air Starters Accessories Index Accessories Index By Description Accessory IR Page Description Part # Number Relay Valves SRV100 SRV125 SRV125T SRV150 SRV150SS Relay Valve Tune Up Kit SRV150-TK3 J-3 J-4
More informationSafety & Shut-off Blocks
Safety & Shut-off Blocks Description HYDAC safety and shut-off blocks are designed to protect, shut-off, and discharge hydraulic accumulators or user units. The compact design simplifies the hydraulic
More informationPACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.
PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE www.elwood.com 0 0 1 : 0 0 0 C E R T I F I E D C O M P A N Y 4-Way 3-Postion Valve 4-WAY, 3-POSITION DIRECTIONAL VALVE, AIR SOLENOID OPERATED SHOWN; DIRECT
More informationActuators & Positioners Models UP1/2/3/4/5/6/7. Universal Pneumatic Rotary Actuators
Data Sheet D-A-UP_G Actuators & Positioners Models UP1/2/3/4/5/6/7 Universal Pneumatic Rotary Actuators Wide Range of Torque Ratings Six actuator sizes available in ratings from 122 to 7320 Newton meter
More informationPriming Systems Installation Instructions
Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...
More informationTests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator
Section 8.1 Tests & Adjustments - General Machine General Safety......................................... 8.1.2 Hydraulic Tank Turbo Boost Regulator........................ 8.1.2 Hydraulic Tank Safety
More informationEclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions
Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions
More informationEaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps
Eaton Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction....................................................... 3 Identification of Components.........................................
More informationI N S T R U C T I O N M A N U A L
I N S T R U C T I O N M A N U A L M E T E R I N G P U M P S LINC84T-17, 18 & 20 Series Chemical Metering Pump Pneumatic Plunger T A B L E O F C O N T E N T S Contents - 84T-17, -18 & -20 Pump Manual...
More informationOildyne. Miniature Piston Pumps 5 Piston Design. Pressures to 276 bar (4000 psi) Displacements from.156cc/rev to.865cc/rev (.01 to.
Oildyne 5 Piston Design Pressures to 276 bar ( psi) Displacements from.156cc/rev to.865cc/rev (.1 to.5 in 3 /rev) 29 Features Pumping Efficiencies to 9% Allow You to Effectively Use.156 to.865 cc Flow
More informationLarge Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions
Engineering & Manufacturing Solutions LEFC Specifications: See flow chart for capacity. Max. 3000 psi cartridge input pressure. Nominally Rated for 3000 psi (207 bar). Tank Port - #4 SAE (10 psi (0.69
More informationSpreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86
Spreader Valves, & SCHEMATIC MODEL PRESSURE FLOW* WEIGHT Quick Reference Page 3 Spreader Valve, Dual Flow Regulation, Compensated, Manual Dump, Gear Pump Circuit 138 bar [2000 psi] [30 US g/m] 2.62 kg
More informationPARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M
PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M ENGINE: HONDA ENGINE OIL GRADE: SAE 10W-30 ENGINE OIL CAPACITY: 67.6 oz. MAXIMUM PRESSURE: COMPRESSOR OIL GRADE: COMPRESSOR OIL CAPACITY: 175
More informationSINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C
D E M A SINGLE-STAGE MODELS SINGLE-STAGE MODELS 1. PARTS A. Injector B. Backup washer (Models 204C & smaller). C. Ceramic Weight. D. Tubing 8 long w/ foot strainer. E. Three brass nozzle bushings Metering
More informationEFC. Electronically Adjustable Proportional Pressure Compensated Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Port size #12SAE (1-1/16 12). 10-Micron Filtration Recommended.
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More informationFLOW CONTROL VALVES A5-1 PN# / / ACC
FLOW CONTROL VLVES Flow Control Valves The HYDC family of flow control valves permit safe, simple and repeatable control of hydraulic fluids at operating pressures to psi. The standard slotted control