LSRPM - UNIDRIVE SP Synchronous motors with permanent magnets-drive 0.75 to 400 kw

Size: px
Start display at page:

Download "LSRPM - UNIDRIVE SP Synchronous motors with permanent magnets-drive 0.75 to 400 kw"

Transcription

1 4176 en / a Permanent Magnet Solutions LSRPM - UNIDRIVE SP Synchronous motors with permanent magnets-drive 0.75 to 400 kw Selection guide

2 A modular offer LS SOFT Software + cables RS485 or USB/RS22 Afficheur LCD Multilingual console Operator interfaces Extension and integrated functions SM Application SMART CARD Save and copies all the parameters SM I/O Plus Speed position feedback SM Resolver Communication SM Universal encoder SM-DeviceNet SM-CAN Open SM-Profibus SM-Ethernet SM-Interbus UT 02 15V 1 Single Ended Extension function Choke EMC filter dv / dt filter Braking resistance Speed sensor return connecting cables s LSRPM Speed position feedback Fixation Hall effect sensor, absolute and incremental encoders, resolvers IM IM IM 9101 Mechanical extension Protections Thermal protections Drip cover Insulated bearings Axial forced - ventilation 2nd shaft end The option characteristics are described in the technical documents for the relevant products. 1 : UT02 required to manage the Hall effect sensor.

3 LSRPM: PERMANENT MAGNET ROTOR TECHNOLOGY IN A MECHANICALLY PROVEN IP55 INDUCTION MOTOR At the peak of efficiency Weight kg Compactness Power - Weight ratio A.C. induction motor η % LSRPM Energy savings Efficiency Power kw LSRPM EFF1 A.C. induction motor Speed min -1 Characteristics: IP55, IK08, acc. to IEC Power rating 0.75 to 400 kw Torque 1 to 1400 Nm - Speed 1 to 5500 min-1 - Frame size 90 to 15 mm Gain in compactness up to frame sizes - Reduction in the weight and dimensions of the motor - Simplification through removal of transmission devices: pulleys, belts, gearboxes Exceptional gains in efficiency over the entire speed LSRPM Synchronous permanent magnet motors Aluminium alloy frame - 0,75 to 400 kw Technical catalogue - Reduction in energy bills - Increase in service life and simplification of maintenance Variable speed operation - Constant torque over the entire speed - Optimized with centrifugal torque applications LSRPM 225 SR2 : 4500 min -1 / 170 kw / 1 A LSRPM 0 LU2 : 4500 min -1 / 150 kw / 288 A LSRPM 0 L1 : 4500 min -1 / 1 kw / A LSRPM 0 L1 : 4500 min -1 / kw / 186 A LSRPM 0 L : 4500 min -1 / 80 kw / 157 A LSRPM 0 L : 4500 min -1 / 65 kw / 128 A

4 UNIDRIVE SP: A NEW-GENERATION DRIVE WHICH MEETS ALL USER EXPECTATIONS Unlimited options! Performance - Manipulate, position, synchronize, cut, print rapidly, with repeat accuracy, in complete safety Simplicity - Install and start using your system quickly and easily without any special training Flexibility - Adapt your system to the various production constraints in a responsive yet inexpensive way Reduced costs - Integrate the control system functions relating to the application - Réduire le nombre de composants et le câblage associé

5 Introduction DYNEO offers innovative, high-performance solutions consisting of synchronous motors with permanent magnets in the rotor circuit and LEROY-SOMER variable speed drives. Combined with the UNIDRIVE SP drive, the innovative LSRPM permanent magnet synchronous motor technology is revolutionizing the electric motor by offering solutions adapted to the industrial environment and by providing optimal electrical mechanical thermal performance: Extended speed High torque over the entire operating speed Very high efficiency Compact design The LSRPM - UNIDRIVE SP combinations described in this manual are suitable for most applications: ventilation, pumping, compression, materials handling, conveying, centrifuging, extrusion, etc. Appropriate add-ons or options for drives and motors can be included to satisfy the demands of the various processes. For further information about the products described in this manual, please consult the corresponding technical documentation. NB: LEROY-SOMER reserves the right to modify the design, technical specifications and dimensions of the products and solutions shown in this document. The descriptions cannot in any way be considered contractual.

6 Contents PAGE Selection method... 1 Selection charts to 5500 min to 4500 min to 600 min to 000 min to 2400 min to 1800 min to 1500 min to 900 min to 750 min to 75 min General drive characteristics... 2 Weights & dimensions Adapting the drive and motor when installing Designation... 28

7 Selection method Example A machine requires torque of 0 N.m over a speed from 800 to 40 min -1 in continuous duty. The maximum torque is 240 N.m. Step 1: Choice of a) Select the according to the speed Selection charts to 5500 min to 4500 min to 600 min Example: Selection of the 4500 for operation from 800 to 40 min -1 b) Select the torque c) Select the motor: choose the curve with a torque rating immediately above that required by the application (pages 2 to ) Torque from 0 to 60 N.m 2 LSRPM 225 SR1 : 4500 min -1 / 170 kw / 1 A LSRPM 0 LU1 : 4500 min -1 / 150 kw / 288 A LSRPM 0 L1 : 4500 min -1 / 1 kw / A 5 LSRPM 0 L : 4500 min -1 / kw / 186 A 6 LSRPM 0 L : 4500 min -1 / 80 kw / 157 A LSRPM 0 L1 : 4500 min -1 / 1 kw / A 5 LSRPM 0 L : 4500 min -1 / kw / 186 A 6 LSRPM 0 L : 4500 min -1 / 80 kw / 157 A Example: Selection of curve 5 for an application requirement of 0 N.m. 5 LSRPM 0 L : 4500 min -1 / kw / 186 A Example: Selection of the torque 0 to 60 N.m for a torque requirement of 0 N.m Rated Rated output Rated type speed current Step 2: Choice of drive (pages to 21) Designation 4500 Rated LSRPM90SL 6,8 LSRPM90L 8,5 LSRPML 10,2 LSRPML 12 Drive designation Available To rque Current 1 Minimum To tal switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D η T J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 5,5T SP ,9 1,1 14, ,10 SP 8T SP , ,5 12,6 18,90 SP 8T SP , 17,5 19, 15, 16,8 SP 11T SP , ,0 15,7 2,55 SP 11T SP , ,0 18,8 2,10 SP 16T SP ,2 22,0 18,8 28, SP 11T SP , ,4 21 2,10 SP 16T SP ,5 22,00 To rque curve no. 4 91,6 0, ,1 0, ,1 0, ,6 0, LSRPML 1,7 SP 16T SP 240 1,7 29 1, 25 1, ,6 0, LSRPM12M 18,6 SP 16T SP ,5 0,5 5,8 27,2 1,90 SP 22T SP ,6 9 42,9 5 8, ,6 0, LSRPM12M 2 SP 27T SP ,9 4 47,0 4 92,6 0, LSRPM12M 27 SP T SP , ,60 4 9,1 0, LSRPM160MP 5 LSRPM160MP 44 LSRPM160LR 52 LSRPM0L 65 LSRPM0L 80 SP T SP 40 27, ,2 5,4 61,60 SP 40T SP , ,80 SP 50T SP , ,50 SP 50T SP , ,0 SP 60T SP , ,50 SP 50T SP , ,5 8 91,0 SP 60T SP , ,40 SP 75T SP , ,50 SP 75T SP ,80 SP T SP ,00 SP 75T SP , ,80 SP T SP ,80 SP 1T SP ,1 0, ,6 0, ,6 0, ,1 0, ,8 0, LSRPM0L SP 1T SP , 0, LSRPM0L1 1 SP 1T SP SP 150T SP SPMA S ,5 0, LSRPM0LU1 150 SPMA S ,1 0, LSRPM0LU1 170 LSRPM250SE SPMA S SPMA S SPMA S SPMA 1401-S ,2 0, ,4 0, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. η T = efficiency X drive efficiency. a) Select the curve no. in the table b) Select the drive rating according to the rated and maximum torque required by the application Example: Selection of drive for an application requiring rated torque of 0 N.m and maximum torque of 240 N.m. Choice of drive: where Mn = 212 N.m and Mmax = 247 N.m SP 1T Drive type Drive rating 1

8 Torque-speed characteristics 5500 Torque from 0 to 24 N.m Torque from 24 to 90 N.m 90 5 LSRPM 160 LR : 5500 min -1 / 52 kw / 97 A LSRPM L : 5500 min -1 / 1,8 kw / 25 A 80 6 LSRPM 160 MP : 5500 min -1 / 44 kw / 82 A 12 LSRPM L : 5500 min -1 / 12,1 kw / 22 A 1 LSRPM L : 5500 min -1 / 10,4 kw / 19 A LSRPM 160 MP : 5500 min -1 / 5 kw / 67 A LSRPM 90 L : 5500 min -1 / 8,6 kw / 15,8 A LSRPM 90 SL : 5500 min -1 / 6,9 kw / 12,7 A Torque from 90 to 240 N.m LSRPM 0 L1 : 5500 min -1 / 140 kw / 267 A LSRPM 0 L : 5500 min -1 / kw / 195 A LSRPM 0 L : 5500 min -1 / 85 kw / 169 A 4 LSRPM 0 L : 5500 min -1 / 70 kw / 18 A For operation at very low speeds, refer to the technical motor catalogue reference

9 Selection charts 5500 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL 6,9 LSRPM90L 8,6 LSRPML 10,4 LSRPML 12,1 LSRPML 1,8 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 5,5T SP ,0 10,4 11, ,1 SP 8T SP , ,0 12,7 19,1 SP 8T SP , 14,5 16,0 15, 16,8 SP 11T SP , ,9 15,8 2,1 SP 11T SP , ,9 19 2,1 SP 16T SP , , ,5 SP 11T SP ,7 18,5 21,9 19,5 2,1 SP 16T SP ,1 21 0,5 22 1,9 SP 16T SP ,8 22 0, 2,2 1,9 SP 22T SP 401 1,8 24 6,0 25 7,5 Torque curve no. 6 91,6 0, ,1 0, ,1 0, ,6 0, ,6 0, LSRPM12M 18,6 SP 22T SP ,6 2 5,2 5 8,5 6 92,1 0, LSRPM12M 2 SP 27T SP ,0 4 47, 6 92,1 0, LSRPM12M 27 SP 40T SP , ,0 6 92,6 0, LSRPM160MP 5 LSRPM160MP 44 LSRPM160LR 52 LSRPM0L 70 SP 40T SP , ,8 SP 50T SP , , SP 60T SP ,0 67,5 SP 50T SP , , , SP 60T SP , ,4 SP 75T SP , ,0 SP 60T SP , ,9 95,1 114,4 SP 75T SP , ,5 SP 75T SP , ,8 SP T SP ,8 SP 1T SP ,0 6 92,6 0, ,1 0, ,1 0, , 0, LSRPM0L 85 SP 1T SP ,1 246,0 6 9,7 0, LSRPM0L SPMA S ,0 0, LSRPM0L1 140 SPMA S ,7 0, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency.

10 Torque-speed characteristics 4500 Torque from 0 to 29 N.m Torque from 29 to 110 N.m 8 LSRPM 160 LR : 4500 min -1 / 52 kw / 97 A 0 14 LSRPM L : 4500 min -1 / 1,7 kw / 25 A 9 LSRPM 160 MP : 4500 min -1 / 44 kw / 81 A LSRPM L : 4500 min -1 / 12 kw / 22 A 16 LSRPM L : 4500 min -1 / 10,2 kw / 18,8 A LSRPM 160 MP : 4500 min-1 / 5 kw / 67 A 17 LSRPM 90 L : 4500 min -1 / 8,5 kw / 15,7 A LSRPM 12 M : 4500 min-1 / 27 kw / 51 A 12 LSRPM 12 M : 4500 min -1 / 2 kw / 45 A LSRPM 90 SL : 4500 min -1 / 6,8 kw / 12,6 A 40 1 LSRPM 12 M : 4500 min -1 / 18,6 kw / 5 A Torque from 110 to 60 N.m Torque from 60 to 490 N.m 50 2 LSRPM 225 SR1 : 4500 min -1 / 170 kw / 1 A LSRPM 0 LU1 : 4500 min -1 / 150 kw / 288 A LSRPM 0 L1 : 4500 min -1 / 1 kw / A 5 LSRPM 0 L : 4500 min -1 / kw / 186 A 6 LSRPM 0 L : 4500 min -1 / 80 kw / 157 A LSRPM 250 SE : 4500 min -1 / kw / 415 A LSRPM 0 L : 4500 min -1 / 65 kw / 128 A For operation at very low speeds, refer to the technical motor catalogue reference

11 Selection charts 4500 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL 6,8 LSRPM90L 8,5 LSRPML 10,2 LSRPML 12 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 5,5T SP ,9 1,1 14, ,10 SP 8T SP , ,5 12,6 18,90 SP 8T SP , 17,5 19, 15, 16,8 SP 11T SP , ,0 15,7 2,55 SP 11T SP , ,0 18,8 2,10 SP 16T SP ,2 22,0 18,8 28, SP 11T SP , ,4 21 2,10 SP 16T SP ,5 22,00 Torque curve no. 4 91,6 0, ,1 0, ,1 0, ,6 0, LSRPML 1,7 SP 16T SP 240 1,7 29 1, 25 1, ,6 0, LSRPM12M 18,6 SP 16T SP ,5 0,5 5,8 27,2 1,90 SP 22T SP ,6 9 42,9 5 8, ,6 0, LSRPM12M 2 SP 27T SP ,9 4 47,0 4 92,6 0, LSRPM12M 27 SP T SP , ,60 4 9,1 0, LSRPM160MP 5 LSRPM160MP 44 LSRPM160LR 52 LSRPM0L 65 LSRPM0L 80 SP T SP 40 27, ,2 5,4 61,60 SP 40T SP , ,80 SP 50T SP , ,50 SP 50T SP , ,0 SP 60T SP , ,50 SP 50T SP , ,5 8 91,0 SP 60T SP , ,40 SP 75T SP , ,50 SP 75T SP ,80 SP T SP ,00 SP 75T SP , ,80 SP T SP ,80 SP 1T SP ,1 0, ,6 0, ,6 0, ,1 0, ,8 0, LSRPM0L SP 1T SP , 0, LSRPM0L1 1 SP 1T SP SP 150T SP SPMA S ,5 0, LSRPM0LU1 150 SPMA S ,1 0, LSRPM225SR1 170 LSRPM250SE SPMA S SPMA S SPMA S SPMA 1401-S ,2 0, ,4 0, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 5

12 Torque-speed characteristics 600 Torque from 0 to 4 N.m Torque from 4 to 10 N.m 12 LSRPM 160 LR : 600 min -1 / 49 kw / 91 A LSRPM L : 600 min -1 / 12,8 kw / 2 A 19 LSRPM L : 600 min -1 / 11,2 kw / 21 A LSRPM L : 600 min -1 / 9,6 kw / 17,6 A 21 LSRPM 90 L : 600 min -1 / 8 kw / 14,8 A 22 LSRPM 90 SL : 600 min -1 / 6,4 kw / 11,9 A LSRPM 160 MP : 600 min -1 / 41 kw / 77 A 14 LSRPM 160 MP : 600 min-1 / 4 kw / 6 A 15 LSRPM 12 M : 600 min-1 / 26 kw / 48 A 16 LSRPM 12 M : 600 min -1 / 22 kw / 41 A 17 LSRPM 12 M : 600 min -1 / 17,6 kw / A Torque from 10 to 0 N.m Torque from 0 to 770 N.m 7 LSRPM 0 LU1 : 600 min -1 / 125 kw / 241 A 750 LSRPM 280 SD : 600 min -1 / 290 kw / 540 A LSRPM 0 L1 : 600 min -1 / 105 kw / 1 A LSRPM 280 SC : 600 min -1 / 240 kw / 450 A 0 9 LSRPM 0 L : 600 min -1 / 85 kw / 16 A 10 LSRPM 0 L : 600 min -1 / 70 kw / 140 A LSRPM 250 SE : 600 min -1 / 190 kw / 6 A LSRPM 0 L : 600 min -1 / 50 kw / 105 A LSRPM 250 SE : 600 min -1 / 165 kw / 11 A Torque from 770 to 105 N.m LSRPM 15 SP : 600 min -1 / 90 kw / 765 A LSRPM 280 MK : 600 min -1 / 25 kw / 65 A For operation at very low speeds, refer to the technical motor catalogue reference

13 Selection charts 600 Power supply upstream from the 400 V drive Designation Rated Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg LSRPM90SL 6,4 SP 5,5T SP ,9 15,7 17, 11 12,1 SP 8T SP , ,5 11,9 17,9 4 91,1 0, LSRPM90L 8 SP 8T SP ,9 14,8 16,8 SP 11T SP ,5 14,8 22,2 4 91,6 0, SP 8T SP , 22,6 24,9 15, 16,8 LSRPML 9,6 SP 11T SP ,6 26 6,6 17,6 24,8 4 92,1 0, SP 16T SP 240 9,6 26 9,0 17,6 26,4 LSRPML 11,2 SP 11T SP ,2 0,0 21 2,1 SP 16T SP ,2 0 45,0 21 1,5 4 92,1 0, LSRPML 12,8 SP 16T SP ,8 4 51,0 2 4,5 4 92,6 0, SP 16T SP ,5 41, 48,4 27,2 1,9 LSRPM12M 17,6 SP 22T SP , ,4 48,0 4 92,6 0, SP 27T SP , ,5 49,5 LSRPM12M 22 SP 22T SP ,8 49,5 54,5 5 8,5 SP 27T SP , ,0 4 92,6 0, SP 27T SP 402 2, 61,8 68,0 4 47, LSRPM12M 26 SP T SP , ,6 4 9,1 0, SP 40T SP , ,0 SP T SP 40 28,8 79,1 91,2 5,4 61,6 LSRPM160MP 4 SP 40T SP ,7 6 74,8 4 9,1 0, SP 50T SP ,5 6 94,5 SP 40T SP ,2 97,1 106, ,8 LSRPM160MP 41 SP 50T SP , , 4 9,6 0, SP 60T SP , ,5 LSRPM160LR 49 SP 50T SP ,7 118,6 10,5 8 91, SP 60T SP , ,4 4 9,6 0, LSRPM0L 50 SP 60T SP ,4 SP 75T SP , 4 9,1 0, LSRPM0L 70 SP 75T SP ,8 SP T SP ,0 4 9,9 0, LSRPM0L 85 SP T SP , ,8 SP 1T SP ,1 0, LSRPM0L1 105 SP 1T SP SP 150T SP ,8 0, LSRPM0LU1 125 SP 150T SP ,4 260 SPMA S ,9 0, LSRPM250SE 165 SPMA S ,1 0, LSRPM250SE 190 SPMA S SPMA S ,5 0, SPMA S LSRPM280SC 240 SPMA S ,5 0, SPMA 1401-S LSRPM280SD 290 SPMA 1401-S SPMA 1402-S , LSRPM280MK 25 SPMA 1402-S SPMA S , 2, SPMA S LSRPM15SP 90 SPMA S ,5 2, SPMA S The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. Torque curve no. 7

14 Torque-speed characteristics 000 Torque from 0 to 7 N.m Torque from 7 to 140 N.m 18 LSRPM L : 000 min -1 / 11,6 kw / 21 A LSRPM L : 000 min -1 / 10,2 kw / 18,8 A LSRPM L : 000 min -1 / 8,7 kw / 16,2 A LSRPM 160 LR : 000 min -1 / 44 kw / 82 A 1 LSRPM 160 MP : 000 min -1 / 7 kw / 69 A LSRPM 90 L : 000 min -1 / 7, kw / 1,5 A 22 LSRPM 90 SL : 000 min -1 / 5,8 kw / 11 A LSRPM 160 MP : 000 min -1 / 0 kw / 57 A 15 LSRPM 12 M : 000 min-1 / 2 kw / 44 A 16 LSRPM 12 M : 000 min -1 / 19,7 kw / 8 A 17 LSRPM 12 M : 000 min -1 / 15,8 kw / 0 A Torque from 140 to 65 N.m Torque from 65 to 700 N.m 7 LSRPM 225 ST1 : 000 min -1 / 115 kw / A 8 LSRPM 0 L1 : 000 min -1 / 105 kw / 9 A LSRPM 280 SC : 000 min -1 / 2 kw / 428 A 00 9 LSRPM 0 L : 000 min -1 / 85 kw / 166 A LSRPM 0 L : 000 min -1 / 65 kw / 129 A LSRPM 250ME : 000 min -1 / 170 kw / 8 A 11 LSRPM 0 L : 000 min -1 / 50 kw / 102 A 6 LSRPM 250SE : 000 min -1 / 145 kw / 279 A Torque from 700 to 1080 N.m 1 1 LSRPM 15 SP : 000 min -1 / 40 kw / 656 A LSRPM 280 MK : 000 min -1 / 290 kw / 579 A 800 LSRPM 280 MD : 000 min -1 / 260 kw / 495 A For operation at very low speeds, refer to the technical motor catalogue reference

15 Selection charts 000 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL 5,8 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 5,5T SP ,8 19, ,1 SP 8T SP , , ,5 Torque curve no. 89,7 0, LSRPM90L 7, SP 8T SP , 2,2 1,5 19,5 91,1 0, LSRPML 8,7 LSRPML 10,2 LSRPML 11,6 LSRPM12M 15,8 LSRPM12M 19,7 LSRPM12M 2 LSRPM160MP 0 LSRPM160MP 7 LSRPM160LR 44 LSRPM0L 50 LSRPM0L 65 LSRPM0L 85 LSRPM0L1 105 LSRPM225ST1 115 SP 8T SP ,2 26,4 29,1 15, 16,8 SP 11T SP , ,0 16,2 24, SP 11T SP ,2 2 9, 18,8 2,1 SP 16T SP ,2 2 48,0 18,8 28,2 SP 11T SP ,6 7 40,7 21 2,1 SP 16T SP ,6 7 55,5 21 1,5 SP 16T SP , 48 52,8 29 1,9 SP 22T SP , ,0 0 45,0 SP 22T SP ,1 58 6,8 5 8,5 SP 27T SP ,7 6 94,5 8 57,0 SP 27T SP , ,2 4 47, SP T SP , ,0 SP T SP 40 29, , ,6 SP 40T SP , ,5 SP 40T SP , , ,8 SP 50T SP , ,5 SP 50T SP , , SP 60T SP , ,0 SP 60T SP ,4 SP75T SP ,9 SP 75T SP ,8 SP T SP ,0 SP T SP ,8 SP 1T SP SP 1T SP , SP150T SP SP 150T SP SPMA S ,1 0, ,6 0, ,6 0, ,1 0, ,6 0, ,1 0, ,6 0, ,1 0, ,1 0, ,2 0, ,9 0, , 0, ,7 0, ,8 0, LSRPM250SE 145 SPMA S , 0, LSRPM250ME 170 LSRPM280SC 2 LSRPM280MD 260 LSRPM280MK 290 LSRPM15SP 40 SPMA S SPMA S SPMA S SPMA 1401-S SPMA S SPMA 1401-S SPMA 1402-S SPMA 1401-S SPMA 1402-S SPMA S SPMA 1402-S SPMA S SPMA S ,4 0, ,6 0, , ,5 2, ,6 2, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 9

16 Torque-speed characteristics 2400 Torque from 0 to 8 N.m Torque from 8 to 145 N.m LSRPM L : 2400 min -1 / 9,5 kw / 17,7 A 19 LSRPM L : 2400 min -1 / 8,4 kw / 15,6 A LSRPM L : 2400 min -1 / 7,2 kw / 1,4 A 21 LSRPM 90 L : 2400 min -1 / 6 kw / 11,2 A LSRPM 160 LR : 2400 min -1 / 6 kw / 69 A 1 LSRPM 160 MP : 2400 min -1 / 1 kw / 58 A 14 LSRPM 160 MP : 2400 min -1 / 25 kw / 47 A 15 LSRPM 12 M : 2400 min-1 / 19,2 kw / 7 A LSRPM 90 SL : 2400 min -1 / 4,8 kw / 9,1 A LSRPM 12 M : 2400 min -1 / 16, kw / 1 A 17 LSRPM 12 M : 2400 min -1 / 1,1 kw / 25 A Torque from 145 to 400 N.m Torque from 400 to 755 N.m LSRPM 225 MR : 2400 min -1 / kw / 19 A 4 LSRPM 280 SD : 2400 min -1 / 190 kw / 5 A LSRPM 0 L : 2400 min -1 / 80 kw / 168 A 9 LSRPM 0 L : 2400 min -1 / 65 kw / 17 A LSRPM 250 ME : 2400 min -1 / 150 kw / 00 A 0 10 LSRPM 0 L : 2400 min -1 / 50 kw / 101 A LSRPM 250 SE : 2400 min -1 / 125kW / 24 A 11 LSRPM 0 L : 2400 min -1 / 7.5 kw / 75 A Torque from 755 to 1400 N.m LSRPM 15 SR : 2400 min -1 / 10 kw / 607 A 2 LSRPM 15 SP : 2400 min -1 / 285 kw / 567 A LSRPM 280 MK : 2400 min -1 / kw / 462 A For operation at very low speeds, refer to the technical motor catalogue reference

17 Selection charts 2400 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL 4,8 LSRPM90L 6 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 4,5T SP ,6 18,4,2 8,8 9,68 SP 5,5T SP , ,5 9,1 1,65 SP 5,5T SP , ,10 SP 8T SP ,0 11,2 16,80 Torque curve no. 88,7 0, ,7 0, LSRPML 7,2 SP 8T SP ,2 29,0 4,5 1 19,50 90,2 0, LSRPML 8,4 LSRPML 9,5 LSRPM12M 1,1 LSRPM12M 16, LSRPM12M 19,2 LSRPM160MP 24,5 LSRPM160MP 1 LSRPM160LR 6 SP 8T SP ,2 2 5,2 15, 16,8 SP 11T SP ,4 49,5 15,6 2,40 SP 11T SP ,5 8 49,6 17,7 2,10 SP 16T SP 240 9,5 8 56,9 17,7 26,50 SP 11T SP ,0 4 47, 21 2,10 SP 16T SP 240 1, ,0 25 7,50 SP 16T SP , ,1 29 1,9 SP 22T SP , 65 97,5 1 46,5 SP 22T SP ,2 71,9 79,1 5 8,5 SP 27T SP , ,0 7 55,5 SP 27T SP ,9 90,6 99,7 4 47, SP T SP 40 24, , SP T SP 40 29, , ,60 SP 40T SP , , ,00 SP 40T SP , , 68 74,80 SP 50T SP , ,50 90,7 0, ,1 0, ,2 0, ,7 0, ,6 0, ,1 0, ,6 0, ,6 0, LSRPM0L 7,5 SP 50T SP , ,75 9,1 0, LSRPM0L 50 LSRPM0L 65 LSRPM0L 80 LSRPM225MR LSRPM250SE 125 SP 60T SP ,40 SP 75T SP ,45 SP 75T SP ,80 SP T SP ,65 SP T SP ,8 SP 1T SP SP 1T SP SP 150T SP SP 150T SP SPMA S ,7 0, ,0 0, ,4 0, ,6 0, ,1 0, LSRPM250ME 150 SPMA S , 0, LSRPM280SD 190 LSRPM280MK LSRPM15SP 285 LSRPM15SR 10 SPMA S SPMA S SPMA S SPMA 1401-S SPMA 1401-S SPMA 1402-S SPMA 1402-S SPMA S , , 1, ,4 2, , The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 11

18 Torque-speed characteristics 1800 Torque from 0 to 8 N.m Torque from 8 to 145 N.m LSRPM L : 1800 min -1 / 7,2 kw / 1,4 A 19 LSRPM L : 1800 min -1 / 6, kw / 11,8 A LSRPM L : 1800 min -1 / 5,4 kw / 10,2 A 21 LSRPM 90 L : 1800 min -1 / 4,5 kw / 8,5 A 22 LSRPM 90 SL : 1800 min -1 /,6 kw / 6,9 A LSRPM 160 LR : 1800 min -1 / 27, kw / 52 A 1 LSRPM 160 MP : 1800 min -1 / 2 kw / 44 A 14 LSRPM 160 MP : 1800 min -1 / 18,7 kw / 6 A 15 LSRPM 12 M : 1800 min-1 / 14,4 kw / 28 A 16 LSRPM 12 M : 1800 min -1 / 12, kw / 24 A 17 LSRPM 12 M : 1800 min -1 / 9,8 kw / 19 A Torque from 145 to 70 N.m Torque from 70 to 800 N.m 8 LSRPM 225 ST : 1800 min -1 / 70 kw / 142 A LSRPM 280 SD : 1800 min -1 / 150 kw / 295 A 00 9 LSRPM 0 L : 1800 min -1 / 55 kw / 111,5 A LSRPM 280 SC : 1800 min -1 / 125 kw / 248 A 0 10 LSRPM 0 L : 1800 min -1 / 40 kw / 82,5 A 11 LSRPM 0 L : 1800 min -1 / kw / 70,5 A LSRPM 250 ME : 1800 min -1 / kw / 4 A 7 LSRPM 225 MR : 1800 min -1 / 85 kw / 172 A Torque from 800 to 12 N.m LSRPM 15 SR : 1800 min -1 / kw / 457 A LSRPM 15 SP : 1800 min -1 / 195 kw / 87 A 900 LSRPM 280 MK : 1800 min -1 / 175 kw / 6 A For operation at very low speeds, refer to the technical motor catalogue reference

19 Selection charts 1800 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL,6 LSRPM90L 4,5 LSRPML 5,4 LSRPML 6, Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP,5T SP 1404,6 19,9 6,9 7,59 SP 4,5T SP 1405, ,5 6,9 10,5 SP 4,5T SP , , 8,5 9,68 SP 5,5T SP ,5 24 6,0 8,5 12,75 SP 4,5T SP , ,5 8,8 9,68 SP 5,5T SP ,4 29,0 4,4 10,2 12,10 SP 8T SP ,4 29,0 4,5 10,2 15,0 SP 5,5T SP ,9 1 4, ,10 SP 8T SP , 49,5 11,8 17,70 Torque curve no. 87,2 0, ,7 0, ,2 0, ,7 0, LSRPML 7,2 SP 8T SP ,2 8 55, 1,4 19,50 90,2 0, LSRPM12M 9,8 LSRPM12M 12, LSRPM12M 14,4 LSRPM160MP 18,7 LSRPM160MP 2 LSRPM160LR 27, LSRPM0L LSRPM0L 40 LSRPM0L 55 SP 8T SP , ,2 15, 16,8 SP 11T SP ,8 52 6,2 19 2,10 SP 16T SP 240 9, , ,50 SP 11T SP , ,5 21 2,10 SP 16T SP , 65 97,5 24 6,00 SP 16T SP , ,6 28 1,9 SP 22T SP , , SP 16T SP , ,0 29 1,90 SP 22T SP , ,6 5 8,50 SP 27T SP , ,5 6 54,00 SP 27T SP , ,9 4 47,0 SPT SP 40 2, , ,00 SP T SP 40 27, , ,60 SP 40T SP , , ,00 SP 40T SP , ,80 SP 50T SP 4402, ,5 102, SP 50T SP , ,5 91,0 SP 60T SP , ,5 119,60 SP 60T SP , ,40 SP 75T SP , ,5 161,6 90,2 0, ,7 0, ,1 0, ,6 0, ,1 0, ,1 0, ,5 0, ,2 0, ,5 0, LSRPM225ST 70 SP 75T SP , ,8 SP T SP , ,9 9,9 0, LSRPM225- SP T SP , ,80 85 MR SP 1T SP , ,4 94,1 0,2 2 7 LSRPM250ME SP 1T SP SP 150T SP ,4 0, LSRPM280SC 125 SP 150T SP SPMA S ,6 0, LSRPM280SD 150 SPMA S , LSRPM280MK 175 SPMA S SPMA S ,4 1,8 56 LSRPM15SP 195 SPMA S ,5 2, LSRPM15SR SPMA S SPMA 1401-S ,8 2, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 1

20 Torque-speed characteristics 1500 Torque from 0 to 8 N.m Torque from 8 to 145 N.m LSRPM L : 1500 min -1 / 6 kw / 11,2 A 19 LSRPM L : 1500 min -1 / 5,2 kw / 9,9 A LSRPM L : 1500 min -1 / 4,5 kw / 8,6 A 21 LSRPM 90 L : 1500 min -1 /,7 kw / 7,2 A 22 LSRPM 90 SL : 1500 min -1 / kw / 5,9 A LSRPM 160 LR : 1500 min -1 / 22,8 kw / 4 A 1 LSRPM 160 MP : 1500 min -1 / 19,2 kw / 0 A 14 LSRPM 160 MP : 1500 min -1 / 15,6 kw / 0 A 15 LSRPM 12 M : 1500 min-1 / 12 kw / 2 A 16 LSRPM 12 M : 1500 min -1 / 10,2 kw / 19,9 A 17 LSRPM 12 M : 1500 min -1 / 8,2 kw / 16 A Torque from 145 to 50 N.m Torque from 50 to 800 N.m 8 LSRPM 0 LU : 1500 min -1 / 55 kw / 105 A LSRPM 280 SD : 1500 min -1 / 125 kw / 26 A 00 9 LSRPM 0 L : 1500 min -1 / 40 kw / 78,5 A LSRPM 280 SC : 1500 min -1 / 105 kw / 216 A 0 10 LSRPM 0 L : 1500 min -1 / kw / 67 A 11 LSRPM 0 L : 1500 min -1 / 25 kw / 51,5 A LSRPM 250 ME : 1500 min -1 / 85 kw / 169 A 7 LSRPM 225 MR : 1500 min -1 / 70 kw / 142 A Torque from 800 to 1400 N.m LSRPM 15 MR : 1500 min -1 / 2 kw / 48 A LSRPM 15 SP : 1500 min -1 / 175 kw / 55 A LSRPM 280 MK : 1500 min -1 / 145 kw / 294 A For operation at very low speeds, refer to the technical motor catalogue reference

21 Selection charts 1500 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL LSRPM90L,7 LSRPML 4,5 LSRPML 5,2 LSRPML 6 LSRPM12M 8,2 LSRPM12M 10,2 LSRPM12M 12 LSRPM160MP 15,6 LSRPM160MP 19,2 LSRPM160LR 22,8 LSRPM0L 25 LSRPM0L LSRPM0L 40 LSRPM0LU 55 LSRPM225MR 70 LSRPM250ME 85 LSRPM280SC 105 LSRPM280SD 125 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 2,5T SP 140 2, ,6 5 5,50 SP,5T SP ,5 5,8 8,70 SP,5T SP 1404,5 2 25, 6,9 7,59 SP 4,5T SP 1405,7 24 6,0 7,2 10,80 SP 4,5T SP ,5 29 2,6 8,6 9,68 SP 5,5T SP ,5 29 4,5 8,6 12,90 SP 5,5T SP ,2 40, 9,9 12,10 SP 8T SP ,2 49,5 9,9 14,85 SP 5,5T SP ,0 8 41, ,10 SP 8T SP , ,50 SP 8T SP ,8 49,5 54,5 15, 16,8 SP 11T SP , , ,00 SP 11T SP , ,5 19,9 2,10 SP 16T SP , ,5 19,9 29,85 SP 11T SP , ,9 21 2,1 SP 16T SP ,0 2 4,5 SP 16T SP , ,5 29 1,9 SP 22T SP , ,5 0 45,00 SP 22T SP , ,5 5 8,50 SP 27T SP , ,0 7 55,50 SP 27T SP , ,5 4 47,0 SP T SP 40 22, ,5 4 64,50 SP T SP 40 25, ,5 61,60 SP 40T SP ,5 74,60 SP 40T SP 4401, ,80 SP 50T SP ,10 SP 50T SP ,5 91,0 SP 60T SP ,5 11,8 SP 60T SP , ,4 SP 75T SP SP 75T SP , ,80 SP T SP ,9 SP T SP , ,80 SP 1T SP SP 1T SP , SP 150T SP SP 150T SP SPMA S Torque curve no. 85, 0, ,2 0, ,2 0, ,2 0, ,7 0, ,2 0, ,7 0, ,2 0, ,7 0, ,1 0, ,7 0, ,1 0, ,9 0, , 0, ,6 0, ,5 0, ,6 0, , LSRPM280MK 145 SPMA S , 1,8 56 LSRPM15SP 175 LSRPM15MR 2 SPMA S SPMA S SPMA S SPMA 1401-S ,6 2, ,0 2, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 15

22 Torque-speed characteristics 900 Torque from 0 to 8 N.m Torque from 8 to 145 N.m LSRPM L : 900 min -1 /,6 kw / 7 A LSRPM L : 900 min -1 /,1 kw / 6,2 A LSRPM L : 900 min -1 / 2,7 kw / 5,4 A LSRPM 90 L : 900 min -1 / 2,2 kw / 4,6 A LSRPM 90 SL : 900 min -1 / 1,8 kw /,8 A LSRPM 160 LR : 900 min -1 / 1,7 kw / 27 A LSRPM 160 MP : 900 min -1 / 11,5 kw / 22 A LSRPM 160 MP : 900 min -1 / 9,4 kw / 18, A LSRPM 12 M : 900 min -1 / 7,2 kw / 14, A LSRPM 12 M : 900 min -1 / 6,1 kw / 12, A LSRPM 12 M : 900 min -1 / 4,9 kw / 9,9 A Torque from 145 to 50 N.m Torque from 50 to 800 N.m 8 LSRPM 0 LU : 900 min -1 / kw / 65 A LSRPM 280 SD : 900 min -1 / 75 kw / 145 A 00 9 LSRPM 0 L : 900 min -1 / 25 kw / 50,2 A LSRPM 280 SD : 900 min -1 / 60 kw / 112 A 0 10 LSRPM 0 L : 900 min -1 / kw / 42,5 A 11 LSRPM 0 L : 900 min -1 / 15 kw /,5 A LSRPM 250 ME : 900 min -1 / 50 kw / 98 A Torque from 800 to 180 N.m LSRPM 250 SE : 900 min -1 / 40 kw / 76 A LSRPM 15 MR : 900 min -1 / 10 kw / 265 A LSRPM 15 SP : 900 min -1 / kw / 7 A LSRPM 280 MK : 900 min -1 / 85 kw / 175 A For operation at very low speeds, refer to the technical motor catalogue reference

23 Selection charts 900 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL 1,8 LSRPM90L 2,2 LSRPML 2,7 LSRPML,1 LSRPML,6 LSRPM12M 4,9 LSRPM12M 6,1 LSRPM12M 7,2 LSRPM160MP 9,4 LSRPM160MP 11,5 LSRPM160LR 1,7 LSRPM0L 15 LSRPM0L LSRPM0L 25 LSRPM0LU LSRPM250SE 40 LSRPM250ME 50 LSRPM280SD 60 LSRPM280SD 75 LSRPM280MK 85 LSRPM15SP LSRPM15MR 10 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 2T SP ,8 19,9,8 4,18 SP 2,5T SP 140 1, ,5,8 5,70 SP 2,5T SP 140 2, ,7 4,6 5,50 SP,5T SP , ,6 6,90 SP 2,5T SP 140 2,5 26, ,50 SP,5T SP , ,4 8,10 SP,5T SP 1404,1 40 6,2 7,59 SP 4,5T SP 1405,1 50 6,2 9,0 SP,5T SP 1404,5 7,5 41 6,9 7,59 SP 4,5T SP 1405, ,50 SP 4,5T SP , ,8 9,68 SP 5,5T SP , ,9 12,10 SP 8T SP , ,9 14,85 SP 5,5T SP , ,10 SP 8T SP , , 18,45 SP 8T SP2401 7, , 16,8 SP 11T SP , , 21,5 SP 8T SP , , 16,8 SP 11T SP , , 2,1 SP 16T SP 240 9, , 27,5 SP 11T SP , ,1 SP 16T SP , ,0 SP 16T SP 240 1, ,9 SP 22T SP 401 1, ,5 SP 22T SP ,5 8,5 SP 27T SP ,5 48,5 SP 27T SP ,5 47, SP T SP ,5 61,6 SP T SP ,2 61,6 SP 40T SP ,2 72,8 SP T SP 40 28, ,6 SP 40T SP ,8 SP 50T SP , SP 50T SP , SP 60T SP SP 50T SP , , SP 60T SP ,4 SP 75T SP SP 60T SP ,4 SP 75T SP SP 75T SP ,8 SP T SP SP T SP , ,8 SP 1T SP SP 1T SP SP 150T SP SP 150T SP SPMA S Torque curve no. 80,4 0, , 0, , 0, , 0, ,2 0, ,2 0, ,2 0, ,2 0, ,2 0, ,7 0, ,7 0, ,8 0, ,8 0, ,5 0, , ,6 0, ,9 0, , 0, , , , 2, ,7 2, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 17

24 Torque-speed characteristics 750 Torque from 0 to 7 N.m Torque from 7 to 145 N.m LSRPM 160 LR : 750 min -1 / 11,4 kw / 22 A LSRPM 160 MP : 750 min -1 / 9,6 kw / 19 A LSRPM 160 MP : 750 min -1 / 7,8 kw / 15,6 A LSRPM 160 LR : 750 min -1 / 11,4 kw / 22 A LSRPM 160 MP : 750 min -1 / 9,6 kw / 19 A LSRPM 160 MP : 750 min -1 / 7,8 kw / 15,6 A LSRPM 12 M : 750 min -1 / 6 kw / 12,2 A LSRPM 12 M : 750 min -1 / 5,1 kw / 10,5 A LSRPM 12 M : 750 min -1 / 4,1 kw / 8,5 A LSRPM 12 M : 750 min -1 / 6 kw / 12,2 A LSRPM 12 M : 750 min -1 / 5,1 kw / 10,5 A LSRPM 12 M : 750 min -1 / 4,1 kw / 8,5 A Torque from 145 to 45 N.m Torque from 45 to 890 N.m LSRPM 0 LU : 750 min -1 / 27 kw / 5 A 8 LSRPM 0 L : 750 min -1 / 21 kw / 42,5 A 9 LSRPM 0 L : 750 min -1 / 16,5 kw / 4,5 A 10 LSRPM 0 L : 750 min -1 / 12,5 kw / 29 A LSRPM 280 MD : 750 min -1 / 70 kw / 1 A LSRPM 280 SD : 750 min -1 / 55 kw / 107 A LSRPM 250 SE : 750 min -1 / 40 kw / 80 A 6 LSRPM 250 SE : 750 min -1 / kw / 65 A Torque from 890 to 1400 N.m LSRPM 15 MR : 750 min -1 / 110 kw / 225,5 A LSRPM 15 SP : 750 min -1 / 85 kw / 170,5 A For operation at very low speeds, refer to the technical motor catalogue reference

25 Selection charts 750 Power supply upstream from the 400 V drive Designation Rated LSRPM90SL 1,4 LSRPM90L 1,8 LSRPML 2,1 Drive designation Available Torque Current 1 Minimum Total switching rated maximum rated maximum efficiency frequency 2 Moment of inertia weight M n M max I n I max/ 60sec F D J IM B kw LS CT kw N.m N.m A A khz % kg.m 2 kg SP 1,5T SP ,2 16,8 18,5 2,8,08 SP 2T SP , ,50 SP 2T SP ,8 2 26,0,7 4,18 SP 2,5T SP 140 1,8 2 5,7 5,6 SP 2,5T SP 140 2, ,4 5,5 SP,5T SP , ,4 6,6 Torque curve no. 78,4 0, , 0, , 0, LSRPML 2,5 SP 2,5T SP 140 2,5 2, ,5 SP,5T SP , ,5 8, 0, LSRPML 2,8 SP,5T SP , ,7 8,5 84, 0, SP,5T SP 1404, ,9 7,59 LSRPM12M 4,1 SP 4,5T SP , ,5 9,68 84, 0, SP 5,5T SP , ,5 14, LSRPM12M 5,1 LSRPM12M 6 LSRPM160MP 7,8 LSRPM160MP 9,6 LSRPM160LR 11,4 LSRPM0L 12,5 LSRPM0L 16,5 LSRPM0L 21 LSRPM0LU 27 LSRPM250SE LSRPM250SE 40 LSRPM280SD 55 LSRPM280MD 70 LSRPM15SP 85 LSRPM15MR 110 SP 4,5T SP , ,8 9,68 SP 5,5T SP , ,5 12,1 SP 8T SP , ,5 15,8 SP 5,5T SP , ,1 SP 8T SP ,2 18, SP 8T SP , ,7 15, 16,8 SP 11T SP , ,6 2 SP 11T SP , , 19 2,1 SP 16T SP 240 9, ,5 SP 11T SP , ,1 SP 16T SP , ,0 SP 16T SP , ,9 SP 22T SP , ,1 SP 22T SP , ,5 8,5 SP 27T SP , ,5 50,0 SP 22T SP , ,5 SP 27T SP ,5 47, SP T SP ,5 61,6 SP 27T SP , SP T SP ,6 SP 40T SP ,8 SP T SP 40 28, ,6 SP 40T SP ,8 SP 50T SP SP 40T SP ,8 SP 50T SP , SP 60T SP SP 50T SP , , SP 60T SP 440 5, ,4 SP 75T SP SP 75T SP ,8 SP T SP SP T SP , ,8 SP 1T SP ,5 247 SP 1T SP SP 150T SP , , 0, ,2 0, ,2 0, ,2 0, ,7 0, ,7 0, , , , 0, ,2 0, ,6 0, , , , ,4 2, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 19

26 Torque-speed characteristics 75 Torque from 0 to 4 N.m LSRPM L : 75 min -1 / 1, kw / A LSRPM L : 75 min -1 / 1,2 kw / 2,6 A LSRPM L : 75 min -1 / 1 kw / 2, A LSRPM 90 L : 75 min -1 / 0,8 kw / 1,9 A 11 LSRPM 90 SL : 75 min-1 / 0,7 kw / 1,6 A Torque from 4 to 10 N.m LSRPM 12 M : 75 min -1 / 2, kw / 5,1 A 6 LSRPM 160 LR : 75 min -1 / 5,1 kw / 10,6 A LSRPM 160 MP : 75 min -1 / 4, kw / 9 A LSRPM 160 MP : 75 min -1 /,5 kw / 7,4 A LSRPM 12 M : 75 min -1 / 2,7 kw / 5,8 A LSRPM 12 M : 75 min -1 / 1,8 kw / 4,2 A For operation at very low speeds, refer to the technical motor catalogue reference 4122.

27 Selection charts 75 Power supply upstream from the 400 V drive Designation Rated Drive designation Available rated Torque Current 1 Minimum maximum rated maximum Total switching efficiency frequency 2 weight M n M max I n I max/ 60sec F D IM B kw LS CT kw N.m N.m A A khz % kg LSRPM90SL 0,7 SP 1,5T SP , ,5 1,6 2,4 68, LSRPM90L 0,8 SP 1,5T SP , ,9,08 72,5 17 LSRPML 1,0 LSRPML 1,2 LSRPML 1, LSRPM12M 1,8 LSRPM12M 2, SP 1,5T SP , ,,08 SP 2T SP , ,,45 SP 1,5T SP , ,6,08 SP 2T SP , ,6,90 SP 1,5T SP ,25 1,7 5 2,8,08 SP 2T SP , ,50 SP 2T SP ,66 42,5 47,8 4,18 SP 2,5T SP 140 1, ,2 6,0 SP 2,5T SP 140 2,25 56, ,50 SP,5T SP , ,1 7,60 Torque curve no. 7, , , , , LSRPM12M 2,7 SP,5T SP , ,8 8,70 80, LSRPM160MP,5 SP 4,5T SP 1405, ,4 11,1 82, 60 1 LSRPM160MP 4, SP 4,5T SP , ,8 9,68 SP 5,5T SP , ,5 8, LSRPM160LR 5,1 SP 5,5T SP , ,6 12,1 84, The drive parameters must comply with the rated current values to ensure thermal control is maintained, as must the maximum current values to avoid the risk of demagnetisation. 2 In case of a usage with a switching frequency above the minimum switching frequency F D, please refer to the table on page 2 to determine the current values. = efficiency X drive efficiency. 21

28 22 LSRPM - UNIDRIVE SP

29 General drive characteristics Power supply characteristics Environment Characteristics Level Power supply voltage -phase supply: 80V -10% to 480V +10% Input frequency Number of -ups Output frequency 48 to 65 Hz maximum / hr 0 to 000Hz Main electrical characteristics Characteristics Protection Operating temperature Altitude Level IP with cable glands installed 0C to +40 C, up to 50 C with derating 0 m without derating > 0 m: operating temperature derating of 0,6 C per m Drive designation Accepted current value I co (A) at switching frequency of LS CT khz 4 khz 6 khz 8 khz 12 khz 16 khz SP 1,5 T SP ,8 2,8 SP 2 T SP 1402,8,8 SP 2,5 T SP SP,5T SP ,9 6,9 5,9 SP 4,5 T SP ,8 8,8 7,4 5,7 SP 5,5 T SP ,4 5,7 SP 8 T SP , 15, 12,7 10,1 SP 11 T SP ,5 16,7 12,7 10 SP 16 T SP ,2 2, ,8 SP 22 T SP ,5 26, 21 SP 27 T SP ,9 28,6 22,5 SP T SP ,4 44,6 7,9 28,6 - SP 40T SP SP 50T SP SP 60T SP ,1 78,8 - SP 75T SP ,1 - SP T SP SP 1T SP ,1 - SP 150T SP ,4 157,7 - SPMA S SPMA S SPMA 1401-S SPMA 1402-S SPMA S SPMA S SPMA S I co : continuous output current. 2

30 Drive dimensions and weight Drive designation Dimensions (mm) L H P Weight 1.5T to 5.5T T to 16T T to T T to 60T T to T T to 150T SPMA S SPMA S SPMA 1401-S SPMA 1402-S SPMA S SPMA S SPMA S Please consult Leroy-Somer 24

31 dimensions Forced ventilation B and B5 Incremental encoder B and B5 Type Shaft end dimensions D E DA EA LSRPM 90SL/L 28j6 60 Please consult LSRPM L 2k6 80 Leroy-Somer LSRPM 12M 8k j6 60 LSRPM 160MP/LR 48k k6 80 LSRPM 0 L//L1/LU/LU1 55m m6 110 LSRPM 225 ST/ST1/SR/SR1/MR 60m m6 140 LSRPM 250 SE/ME 65m m6 140 LSRPM 280 SC/SD 70m m6 140 LSRPM 280 MD 75m m6 140 LSRPM 280 MK 75m m6 140 LSRPM 15 SP/SR 80m m6 170 LSRPM 15 MR 85m m6 170 Main dimension Type AB AC HD LB LB1 LB2 IEC flange LSRPM 90SL/ L FF165 LSRPM L FF215 LSRPM 12 M FF265 LSRPM 160 MP/LR FF00 LSRPM 0L FF50 LSRPM 0 L FF50 LSRPM 0 LU FF50 LSRPM 225 ST FF400 LSRPM 225 ST FF400 LSRPM 225 SR FF400 LSRPM 225 SR FF400 LSRPM 225 MR FF400 LSRPM 250 SE/ME FF500 LSRPM 280 SC FF500 LSRPM 280 SD/MD FF500 LSRPM 280 MK FF500 LSRPM 15 SP FF600 LSRPM 15 SR/MR FF600 25

32 Adapting the drive and motor when installing Supplies network and equipment incorporating electronics may generate disturbance affecting each element: motor, drive and network. This chapter Adapting the drive and motor when installing is a rough guide to choosing the eventual options required to suit the use and installation. General conditions The selection guide is used: To conform the installation conform to the wiring instructions, To the following specifications with a standard LSRPM motor - Mains imbalance 2%, - Mains voltage 400 to 480 V ± 10 %, - Drive switching frequency: indicated in the selection charts, - insulation Class F, - Voltage peaks generated at the motor terminals blocks 1500 V, - motor dv / dt < 500 V/ms. Special conditions To satisfy the demands of specific applications and harsher operating conditions, LEROY-SOMER offers additional options (ask for estimate): dv / dt filter, Reinforced insulation (motor), Insulated bearings for motors frame size 0 mm. Risk assessment: OI drive emergency shutdown, Damage to the motor insulation, Reduced motor bearing life, according to the three parameters DC bus voltage U, motor cable length l and motor rating P. Very low risk High risk NB: In special cases our technicians can conduct an in-depth study of the installation to guarantee that it works correctly (ask for estimate). 26

33 Option selection guide Adapting the drive and motor to the installation dv /dt filter: High frequency repetitive peak voltage and resulting circulating current in the cables can cause an «OI» emergency shutdown indicated on the drive. Use of the filter is recommended in the following cases: - Application with braking and when the cable length is more than 0 meters. - In applications where the cable length is more than the maximum value indicated in the chart below (this maximum length depends on the drive rating and the switching frequency F D ). UNIDRIVE SP rating 1,5 T 2,8 2 T,8 2,5 T 5,5T 6,9 4,5 T 8,8 5,5 T 11 8 T 15, 11 T T T 5 27 T 4 T 56 40T 68 50T 8 60T T 18 T 168 1T 5 150T 26 SPMA S 90 SPMA S 449 SPMA 1401-S 585 SPMA 1402-S 674 SPMA S 780 SPMA S 899 SPMA S 976 Max. cumulative* length of cables (* : for motors or cables in parallel) Ico FD 2 & khz FD,5 & 4 khz FD 4,5 & 5 khz FD 5,5 & 6 khz (A) m m m m to be advised Reinforced insulation Voltage peaks generated at the terminals on each pulse in the signal can have a destructive effect on the winding. These peaks, which are related to the value of the supply voltage upstream of the drive, can cause the turns of the winding to short-circuit. For peak values greater than 1500 V, the SIR (reinforced winding insulation) option is available over the entire. The permitted value of the voltage peak at the motor terminals would then be 00 V. Use of this option is recommended in the case of an application involving braking and when the cable length is more than 0 meters. UT 02 15V Modul Single Ended Can be incorporated on the driver encoder input, and used to manage the motor speed/ position feedback. It manages the Hall effect sensors (as standard for the LSRPM). 27

34 Designation Drive SP 1 T Option(s) 2 Type Rating (kva) 1.5 to 150 T: 400 to 480V TM: 500 to 575V TH: 500 to 690V 2 described in this document (add UT 02 for the speed return Modular drive SPMA S Option(s) 2 2 Type SPMA: modular drive to 480V to 575V to 690V Current rating S: 6 pulses T: 12 pulses R: Regen 1: simple rectifier With braking transistor Number of modules in parallel 2 described in this document (add UT 02 for the speed return 5500 LSRPM 280 L 140 kw IM 1 (IM B) 400 V IP 55 Range Shaft height Rated output Power supply Protection Series designation Mounting arments IEC 4-7 Housing designation and manufacturers index 28

35 29

36 0 LSRPM - UNIDRIVE SP

37 1

38 MOTEURS LEROY-SOMER ANGOULEME CEDEX-FRANCE RCS ANGOULÊME S.A. au capital de

DYNEO VARIABLE SPEED DRIVES Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors

DYNEO VARIABLE SPEED DRIVES Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet 0.75 kw to 400 kw Technical catalogue 4936 en - 2012.10 / b Rectifier Simplicity Performance Install and start using your system quickly

More information

DYNEO VARIABLE SPEED DRIVES Unidrive M variable speed drives LSRPM permanent magnet synchronous motors to 85 kw. Technical catalogue

DYNEO VARIABLE SPEED DRIVES Unidrive M variable speed drives LSRPM permanent magnet synchronous motors to 85 kw. Technical catalogue Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 0.75 to 85 kw Technical catalogue 5034 en - 2013.09 / b Unidrive M range 0.75 kw to 90 kw 100 200 400 575 690 Vac Ethernet Onboard

More information

Dyneo Motors and Drives. Powerdrive F300 variable speed drives LSRPM permanent magnet synchronous motors 1.1 kw to 250 kw

Dyneo Motors and Drives. Powerdrive F300 variable speed drives LSRPM permanent magnet synchronous motors 1.1 kw to 250 kw Dyneo Motors and Drives Powerdrive F300 variable speed drives LSRPM permanent magnet synchronous motors 1.1 kw to 250 kw Powerdrive F300 range 1.1 kw to 2.8 MW Range of IP20 drives to be integrated in

More information

DYNEO VARIABLE SPEED DRIVES Powerdrive FX & MD2 S variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors

DYNEO VARIABLE SPEED DRIVES Powerdrive FX & MD2 S variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors Powerdrive FX & MD2 S variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors 22 kw to 400 kw Technical catalogue 5006 en - 2013.11/b Innovative "C light" technology New patented CL4Q

More information

Dyneo Motors & Drives. Powerdrive FX & MD2 variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors 18 kw to 500 kw

Dyneo Motors & Drives. Powerdrive FX & MD2 variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors 18 kw to 500 kw Powerdrive FX & MD2 variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors 18 kw to 500 kw Powerdrive FX range 18 kw to 90 kw Drives with dynamic braking Integrating C-Light 4 Quadrant

More information

Dyneo Motors & Drives. Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 0.75 kw to 220 kw

Dyneo Motors & Drives. Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 0.75 kw to 220 kw Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 0.75 kw to 220 kw Unidrive M range 0.25 kw to 2.8 MW Customized range of drives to meet the needs of industrial sectors The Unidrive

More information

LSES high efficiency three-phase asynchronous motors General information

LSES high efficiency three-phase asynchronous motors General information General information Efficiency class IE2 Totally enclosed three-phase powersaving asynchronous motors, LSES series, according to IEC 60034, 60038, 60072 ; power 0.75 to 200 kw, frame size 80 to 315 mm.

More information

Enclosed three-phase asynchronous motors driven by electronic drive LSMV General information

Enclosed three-phase asynchronous motors driven by electronic drive LSMV General information General information Enclosed 3-phase asynchronous motors, series, according to IEC 60034, 60072. motor is the result of Leroy-Somer s experience with speed variation and progress in performance of new

More information

VARMECA variable speed asynchronous motors with FCR brake LS VARMECA FCR. General information

VARMECA variable speed asynchronous motors with FCR brake LS VARMECA FCR. General information General information VARMECA, the result of long experience in variable speed, benefits from a a compact size and reduced weight. Currently it is available up to 11. VARMECA generates no noise pollution

More information

Unidrive M700 Class leading performance with onboard real-time Ethernet

Unidrive M700 Class leading performance with onboard real-time Ethernet Unidrive M Class leading performance with onboard real-time Ethernet. kw -.8 MW Heavy Duty (. hp -, hp) V V V 9 V Unidrive M features Easy click-in keypad connection Range of multi-language LCD keypads

More information

LSES high efficiency three-phase asynchronous motors. General information

LSES high efficiency three-phase asynchronous motors. General information Efficiency class IE2 General information Totally enclosed three-phase saving asynchronous motors, series, according to IEC 60034, 60038, 60072 ; 0.75 to 200 kw, frame size 80 to 315 mm. Single speed: 2,4

More information

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information General information Non-sparking totally enclosed threephase asynchronous motors, LSN series, according to IEC 60034, 60072, IEC 60079-1 and 60079-15. Single speed: power 0.75 to 90 kw 1, frame size 80

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

Dyneo Motors & Drives. Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 13 hp (9.8 kw) to 321 hp (240 kw) 460 V

Dyneo Motors & Drives. Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 13 hp (9.8 kw) to 321 hp (240 kw) 460 V Dyneo Motors & Drives Unidrive M variable speed drives LSRPM permanent magnet synchronous motors 13 hp (9.8 kw) to 321 hp (240 kw) 460 V 2 www.emersonindustrial.com/automation High-performance Solutions

More information

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm 95 Nm to 2900 Nm Introduction The range of IP23 protection CPLS asynchronous motors was designed for fixed and variable speed applications when there is little space available or (and) there is a wide

More information

Variable speed asynchronous motors with FCPL brake LSMV FCPL. General information

Variable speed asynchronous motors with FCPL brake LSMV FCPL. General information General information GENERAL USE : U.G. Enclosed three-phase asynchronous brake motors, LSMV series with failsafe continuous current (dc) brake, according to IEC 60034, 60072, EN50281. Separate mains supply

More information

Express Availability Commitment. The Drives, Motors, Geared Motors and Servos you need, whenever you need them

Express Availability Commitment. The Drives, Motors, Geared Motors and Servos you need, whenever you need them Commitment The Drives, Motors, Geared Motors and Servos you need, whenever you need them Commitment Drives, Motors, Geared Motors and Servos, whenever you need them As part of Nidec, Control Techniques

More information

FCR asynchronous brake motors LS FCR. General information

FCR asynchronous brake motors LS FCR. General information General information LIFTING USE : U.L. Enclosed three-phase asynchronous brake motors, LS series with failsafe brake, according to IEC 34, 72, EN 50281. Single speed : 0.55 to 15, frame size from 80 to

More information

PLS Open Drip Proof three-phase asynchronous motors. General information

PLS Open Drip Proof three-phase asynchronous motors. General information General information Open Drip Proof three-phase asynchronous motors, series PLS, according to IEC 60034, 60066, 60072 power 7,5 kw to 900 kw, frame size 160 to 400 mm, 2, 4, 6 and 8 ; 230/400 V or 400

More information

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information (E) Atmospheres containing explosive GAS General information Flameproof totally enclosed three-phase asynchronous motors, FLSD (E) series, according to IEC 60034, 60038, 60072, 60079-0 and 60079-1, EN

More information

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs 0.25 kw - 110 kw (0.33 hp - 150 hp) 100 V 200 V 400 V 575 V 690 V Unidrive M400 features Optional AI-485

More information

VARMECA variable speed asynchronous motors and FCR brake LS VARMECA FCR. General information

VARMECA variable speed asynchronous motors and FCR brake LS VARMECA FCR. General information General information LS VARMECA with FCR brake, the result of a long experience in speed variation, has self certification for atmospheres containing explosive dust category 3, zone 22. Power : 0.25 to

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M Optimized throughput, open automation

More information

Open continuous current (DC) motors MS 1 - MS 2. General information

Open continuous current (DC) motors MS 1 - MS 2. General information MS 1 - MS 2 General information Open continuous current (dc) motors conforming to the IEC specifications. MS 1 : - frame size 80 to 132 mm, - power 0.44 to 8.85 kw. MS 2 : - frame size 112 and 132 mm,

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M Optimized throughput, open automation

More information

DYNEO Synchronous motors with permanent magnets-drive Commissioning

DYNEO Synchronous motors with permanent magnets-drive Commissioning Synchronous motors with permanent magnets-drive NOTE LEROY-SOMER reserves the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments.

More information

Variable speed asynchronous motors with FCR brake LSMV FCR. General information

Variable speed asynchronous motors with FCR brake LSMV FCR. General information General information GENERAL USE : U.G. Closed three-phase asynchronous brake motors, LSMV series with failsafe continuous (dc) brake, according to IEC 3, 72, EN 50281. Single speed : 0.25 to 11, frame

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M Optimized throughput, open automation

More information

Datasheet. Pitch Motor PMSM SP190C8

Datasheet. Pitch Motor PMSM SP190C8 Pitch Motor PMSM SP190C8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260007a 1 Application The Pitch motor

More information

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection Overview 1PL6 motors, shaft heights 180 to 22 Benefits 7 Extremely high power density with small motor dimensions (0 to 60 % higher output as compared to 1PH7 in degree of protection IP) 7 Speed down to

More information

Powerdrive FX Ultra compact regenerative drive solution

Powerdrive FX Ultra compact regenerative drive solution Powerdrive FX Ultra compact regenerative drive solution 22 kw - 90 kw (30 hp - 125 hp) 400 V 480 V Powerdrive FX Drives with dynamic braking Based on innovative C-Light 4 Quadrant technology, the variable

More information

High-efficiency 3-phase induction motors for variable speed control LSMV

High-efficiency 3-phase induction motors for variable speed control LSMV High-efficiency 3-phase induction motors for variable speed control LSMV 0.75 to 132 kw Technical catalogue 4981 en - 2014.07 / c A world-class product C US EN Guaranteed variable speed performance Leroy-Somer

More information

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection Selection and ordering data speed Shaft height power torque voltage Speed during field weakening 1) Continuous speed, max. 2) Speed, max. 3) 1PL6 asynchronous motor Forced ventilation n rated SH P rated

More information

FAP asynchronous brake motors LS FAP. General information

FAP asynchronous brake motors LS FAP. General information General information GENERL USE : U.G. Enclosed three-phase asynchronous brake motor, series LS with failsafe alternating current (ac) brake, according to IEC 60034,60072, EN50281. Separate supply to the

More information

Datasheet. Pitch Motor PMSM SP260B8

Datasheet. Pitch Motor PMSM SP260B8 Pitch Motor PMSM SP260B8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260012a 1 Application The Pitch motor

More information

Datasheet. Pitch Motor PMSM SP190F8

Datasheet. Pitch Motor PMSM SP190F8 Pitch Motor PMSM SP190F8 Permanent Magnet Compact and light weight High peak torque Excellent efficiency Maintenance free, No fan 5 year warranty Document no.: 4121260009c 1 Application The Pitch motor

More information

LSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information

LSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information General information GENERAL USE : U.G. Enclosed three-phase brake asynchronous motors, LSPXMV series with failsafe brake, according to IEC 6003, 60072, EN 50281. Single speed : 0.25 to 11, frame size from

More information

HBI 22. Integrated Three-phase Synchronous Drive

HBI 22. Integrated Three-phase Synchronous Drive HBI 22 Integrated Three-phase Synchronous Drive positioning capability up to 9 Watts rated output power with linear hall sensor system with or without parking brake Motor type Dimension L1 L2 HBI 223 125

More information

water-cooled motor / generator with up to 13 kw continuous power

water-cooled motor / generator with up to 13 kw continuous power water-cooled motor / generator with up to 13 kw continuous power KEY FEATURES permanent magnet synchronous machine water-cooled high peak power for motor applications convincing cost-benefit ratio recommended

More information

Torque motors to Nm. Description. Advantages. TMW series

Torque motors to Nm. Description. Advantages. TMW series Torque motors 200 to 22 000 Nm Description Parker TMW torque motors are innovative direct drive solutions based on brushless technology. Especially designed for low speed operation, they advantageously

More information

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST KAT.NMST.02.14.ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST 90 355 IMPORTANT NOTE: Due to the continious development policy, our companyreserves the right to make changes the values, dimensions

More information

Servo Motors. Unimotor hd, Unimotor fm, NT Series and XV Series lb-in ( Nm) 230 V 460 V

Servo Motors. Unimotor hd, Unimotor fm, NT Series and XV Series lb-in ( Nm) 230 V 460 V Servo Motors Unimotor hd, Unimotor fm, NT Series and XV Series 0.9-1204 lb-in (0.11-136 Nm) 230 V 460 V Contents Introduction: A Servo Motor for Every Application... 1 Drive and Motor Selection... 3 Electronic

More information

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase

More information

simodrive POSMO Intelligent motion control with decentralized solutions Overview March 2003

simodrive POSMO Intelligent motion control with decentralized solutions Overview March 2003 Intelligent motion control with decentralized solutions The SIMODRIVE POSMO series opens up a whole new range of possibilities in the area of machine conception. With SIMODRIVE POSMO, the entire drive

More information

Powerdrive FX Ultra compact regenerative drive solution

Powerdrive FX Ultra compact regenerative drive solution Powerdrive FX Ultra compact regenerative drive solution 30 hp - 125 hp (22 kw - 90 kw) 400 V 480 V Powerdrive FX Drives with dynamic braking Based on innovative C-Light 4 Quadrant technology, the variable

More information

UNIDRIVE M600. Manufacturing Automation drive. High performance drive for induction and sensorless permanent magnet motors

UNIDRIVE M600. Manufacturing Automation drive. High performance drive for induction and sensorless permanent magnet motors UNIDRIVE M600 Manufacturing Automation drive High performance drive for induction and sensorless permanent magnet motors Unidrive M100 Unidrive M200 Unidrive M300 Unidrive M400 Unidrive M600 Unidrive M700

More information

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw CEB 71204/a of 13 december 2005 SLSHR 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw C.E.B. SLSHR RANGE TECHNICAL CATALOGUE 05/12/13 CONTENTS CONTENTS 2 APPLICATIONS

More information

DYNABLOC Geared Servomotors

DYNABLOC Geared Servomotors DYNABLOC Geared Servomotors Selection guide 5082 en - 2014.01 / b DYNABLOC solutions for intermittent duty applications GEARBOX Planetary or worm/wheel with reduced backlash up to 690 N.m Ratios from 3

More information

HANDBOOK -M. Synchronous servo motors

HANDBOOK -M. Synchronous servo motors HANDBOOK -M Synchronous servo motors Contents 1. Technical specification...4 1.1 General...4 1.2 Construction /assembly...4 2. Three phase synchronous motors...5 2.1 Frame type references...5 2.2 Options...5

More information

SMS PRODUCT CATALOGUE

SMS PRODUCT CATALOGUE SMS PRODUCT CATALOGUE CONTENTS 1 TAKEDO 3VF-NXP - LIFT INVERTER Page 3 2 TAKEDO 3VF-V20 - OPEN LOOP LIFT INVERTER Page 6 3 TAKEDO ENERGY - DYNAMIC BRAKING REGENERATIVE UNIT Page 7 4 HYDROVERT VVVF FOR

More information

Unimotor fm 230 V 460 V Unimotor fm 230 V / 460 V

Unimotor fm 230 V 460 V Unimotor fm 230 V / 460 V Unimotor fm 230 V 460 V Unimotor fm 230 V / 460 V Flexible Configuration C Servo Motors Flexible Configuration C Servo Motors Unimotor fm is a high performance, brushless C Servo motor range matched for

More information

Introduction The aim of this application note is to outline how to configure an ACSM1 drive to run with an ABB BSM series AC servo motor.

Introduction The aim of this application note is to outline how to configure an ACSM1 drive to run with an ABB BSM series AC servo motor. Motion Control Products Application note Configuring ACSM1 for use with BSM series servo motors The ABB ACSM1 AC servo drive can provide basic speed or torque control modes as well as versatile motion

More information

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors Series R2, Frame 63 355 Introduction KHM R2 series cast iron motors are totally enclosed fan cooled, 3 phase, and squirrel cage induction

More information

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1 Characteristics brushless dc motor 24..48V- EtherNet/IP interface - L = 174 mm- 18:1 Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number

More information

LSA 52.3 Low Voltage Alternators - 4 pole

LSA 52.3 Low Voltage Alternators - 4 pole LSA 52.3 Low Voltage Alternators - 4 pole 1860 to 2500 kva - 50 Hz / 2230 to 3000 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 52.3 alternator is designed to be

More information

Technical Documentation

Technical Documentation Technical Documentation LOW VOLTAGE THREE PHASE TEFC CAGE MOTORS IE316EN Mission, Vision, Targets Our electric motors and generators are optimized in accordance with our client's technical and economical

More information

Automotive Drive and Motor Solutions for the Automotive Industry

Automotive Drive and Motor Solutions for the Automotive Industry Automotive Drive and Motor Solutions for the Automotive Industry 1 The World is changing. Emerson s engineering resources can help you develop new innovative solutions to meet the challenges of the future

More information

Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional

More information

VARMECA Motors and geared motors with integrated frequency inverter. Réf GB / e

VARMECA Motors and geared motors with integrated frequency inverter. Réf GB / e VARMECA Motors and geared motors with integrated frequency inverter Réf. 2329 GB - 2.33 / e - 04.02 the new integrated frequency inverter SAVING ENERGY and PROTECTING THE ENVIRONMENT : VARMECA is a simple,

More information

Technical Documentation

Technical Documentation Technical Documentation LOW VOLTAGE THREE PHASE TEFC CAGE MOTORS IE315EN Mission, Vision, Targets Our electric motors and generators are optimized in accordance with our client's technical and economical

More information

Low Voltage Alternators - 4 pole LSA 44.3

Low Voltage Alternators - 4 pole LSA 44.3 LSA 44.3 70 to 150 kva - 50 Hz / 88 to 188 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 44.3 alternator is designed to be suitable for typical generator applications,

More information

Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional

More information

PLSES 4500 IMfinity Platform. IP23 high-speed induction motors Industrial refrigeration Variable speed Frame size 225 to to 480 kw

PLSES 4500 IMfinity Platform. IP23 high-speed induction motors Industrial refrigeration Variable speed Frame size 225 to to 480 kw IMfinity Platform IP23 high-speed induction motors Industrial refrigeration Variable speed Frame size 225 to 315 100 to 480 kw The answer to the highly demanding cold storage sector Companies that use

More information

Energy Saving Three Phase Motors

Energy Saving Three Phase Motors e-drive Energy Saving Three Phase Motors IEC frames 56 to 400 Outputs 0.09 to 630 IE2 MEPS2006 Type: AHE Aluminium Motors Type: HE Cast-Iron Motors 1 When you need all the features of a premium quality

More information

Table of contents. Three-phase asynchronous motors DA

Table of contents. Three-phase asynchronous motors DA be in motion be in motion AC Asynchronous Motors DA 100-280 Table of contents 1. Three-phase asynchronous motor DA 100-280... 3 1.1. General technical data... 3 1.2. Ratings definition for ventilated

More information

USER-PROGRAMMABLE AND ROBUST

USER-PROGRAMMABLE AND ROBUST NC FREELY PROGRAMMABLE ROTARY TABLES NC ROTARY TABLE NC ROTARY TABLE: USER-PROGRAMMABLE AND ROBUST OPTIMISED BEARINGS To achieve maximum quality and reliability, even when under load, all roller bearings

More information

ARTIFICIAL LIFT Solutions for customer pains ESP PCP RRP Auxiliaries

ARTIFICIAL LIFT Solutions for customer pains ESP PCP RRP Auxiliaries ARTIFICIAL LIFT Solutions for customer pains ESP PCP RRP Auxiliaries Presented by Jean-Mathieu Renault Automation Solutions team Moteurs Leroy Somer Emerson Industrial Automation Solutions for ESPs Electro

More information

EMC-HD. C 01_2 Subheadline_15pt/7.2mm

EMC-HD. C 01_2 Subheadline_15pt/7.2mm C Electromechanical 01_1 Headline_36pt/14.4mm Cylinder EMC-HD C 01_2 Subheadline_15pt/7.2mm 2 Elektromechanischer Zylinder EMC-HD Short product name Example: EMC 085 HD 1 System = ElectroMechanical Cylinder

More information

SIMOTICS S-1FT7 Servomotors. The Compact Servomotors for High-Performance Motion Control Applications. Motors. Edition April 2017.

SIMOTICS S-1FT7 Servomotors. The Compact Servomotors for High-Performance Motion Control Applications. Motors. Edition April 2017. Motors SIMOTICS S-1FT7 Servomotors The Compact Servomotors for High-Performance Motion Control Applications Brochure Edition April 2017 siemens.com/servomotors The Servomotors for High-Performance Applications

More information

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network

More information

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module. Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module. 1 Upon the completion of this module, you will be able to describe the

More information

MT30R4 D.C. Servomotors

MT30R4 D.C. Servomotors MT30R4 D.C. Servomotors Technical Data Parameter Unit MT30R4-58 MT30R4-46 MT30R4-37 MT30R4-25 GENERAL Voltage Gradient No Load Volts/1000RPM* 58 46 37 25 Max. Terminal Voltage Volts 140 140 140 100 Max.

More information

IMfinity LS FFB - LSES FFB - FLSES FFB Brake motors. Brake Ranges. FFB Brake Motors Offer. Associated documentations. Fixed speed.

IMfinity LS FFB - LSES FFB - FLSES FFB Brake motors. Brake Ranges. FFB Brake Motors Offer. Associated documentations. Fixed speed. Ranges Fixed 4-pole brakes 90 kw FCPL 15 kw 11 kw 9 kw FFB 65 --> 2400 N.m 4.5 --> 200 0.37 kw N.m FMD 0.25 kw 0.06 kw 3 --> 5 N.m Fr. size --> 56 --> 71 71 --> 180 180 --> 280 Associated documentations

More information

1LG0 Low-voltage Motors

1LG0 Low-voltage Motors Low-voltage motors up to 315kW Catalog D81.5.1 1LG Low-voltage Motors Answers for industry. 1 Table of Contents Overview 3 Motor standards 5 Mechanical design 6 Electrical design 1 Converter fed application

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

Open continuous current (DC) motors LSK. General information

Open continuous current (DC) motors LSK. General information LSK General information LSK open continuous current (dc) motors frame size 112 to 355 mm, power 2 to 750 kw. Conditions of use According to the standard EC 34-1, the standard motors can operate in the

More information

Asynchronous motors. 5 Asynchronous motors 5/2 Type overview and rated data 5/4 Technical definitions 5/4 Encoder systems

Asynchronous motors. 5 Asynchronous motors 5/2 Type overview and rated data 5/4 Technical definitions 5/4 Encoder systems / Type overview and rated data /4 Technical definitions /4 Encoder systems / PH7 motors / PH7 motors, forced ventilation / Permissible combinations of mechanical designs for PH7 motors, shaft 8 /4 PL motors

More information

OptIMity 3-phase induction motors

OptIMity 3-phase induction motors OptIMity 3-phase induction motors IE&IE3 Frame Size 80-355 Power Rating 0.37-355Kw Drives & Motors Technology Core Offering in Asia Pacific Process AC Drives Powerdrive MD & F300 Construction & Infrastructure

More information

SINGLE PHASE TEFC CAGE MOTORS

SINGLE PHASE TEFC CAGE MOTORS SINGLE PHASE TEFC CAGE MOTORS 2 SINGLE PHASE TEF CAGE MOTORS Mechanical protection: IP 54 Voltage: 220 V, 50 Hz Type Output power P N kw Rated speed n N min -1 Efficiency % Power factor cos Rated current

More information

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1 Characteristics brushless dc motor 24..36 V - Profibus DP interface - L = 174 mm - 18:1 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1640.00 USD Main Range

More information

Electric cylinders CASM

Electric cylinders CASM Electric cylinders CASM 32-4-63 Contents Product description 4 Motors and gearboxes 6 Manuals 1 3D models 1 Linear unit 3 12 Linear unit 4 14 Linear unit 63 16 linear unit 18 Actuator 32 2 Actuator 4 32

More information

The statements in this data sheet are for information, only. They do not guarantee properties. We reserve the right to make changes without notice.

The statements in this data sheet are for information, only. They do not guarantee properties. We reserve the right to make changes without notice. DMASS servo motor with high power denisty from 7.5KW up to 250KW Model DSM-95 Applications plastic machinery machine tools textile machinery logistics machinery press manufacture Special Features high

More information

Servo drives. Compact Drives IndraDrive Cs

Servo drives. Compact Drives IndraDrive Cs Compact Drives IndraDrive Cs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Highly versatile, extremely compact drives 100 W 3.5 kw Ethernet-based communications, multi-protocol support

More information

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters General Information From their basic function, motors with efficiency class IE4 are synchronous motors and are suitable

More information

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Product availability : Stock - Normally stocked in distribution facility Price* : 840.00 USD Main Range

More information

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

ELECTRIC MOTORS. Selection. Starting torque and nominal torque SELECTION PROCEDURE The output powers published overleaf are based upon continuous maximum rating conditions. Therefore design factors for above average running periods do not normally affect the selection.these

More information

Table of contents. Three-phase asynchronous motors DA

Table of contents. Three-phase asynchronous motors DA Table of contents 1. Three-phase asynchronous motor DA 100-280... 5 1.1. General technical data... 5 1.2. General safety instructions... 6 1.3. Definitions of power ratings... 7 1.3.1. Definitions of power

More information

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES FRAMES 355 560 355kW 1500kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in

More information

AC Servodrives Bivector 300/500 Advanced solutions for automation

AC Servodrives Bivector 300/500 Advanced solutions for automation AC Servodrives Bivector 300/500 Advanced solutions for automation ABB Automation Bivector Field Oriented Torque Control - optimal working point setting for maximum KT - robust control in flux weakening

More information

INVEOR "Smart connections." on five levels

INVEOR Smart connections. on five levels INVEOR "Smart connections." on five levels 1 The Inveor 3 Operation and observation IP65 protection class Integrated soft PLC Pre-fitted cable glands Fan-free design up to 7.5 kw Robust and vibration-resistant

More information

High performance Vector Control. Ratings. System configuration

High performance Vector Control. Ratings. System configuration System configuration High performance Vector Control Low harmonic or regenerative drive IP54 full range Compact design and robustness Built-in filter (according to C3 class) Built-in fuses (from 200 kw)

More information

MBT low voltage motors. General information

MBT low voltage motors. General information General information Low enclosed continuous current (DC) motors MBT : - Excitation by permanent magnets. - Power 0.06 to 0.75 kw. - IP 40 protection (MBT 65-82) - IP 40 - IP 20 (MBT 1141) MBT 65 : 2 poles

More information

ST AND SW TORQUE ROTARY UNITS

ST AND SW TORQUE ROTARY UNITS ST/SW ROTATING UNITS ST/SW TORQUE ROTARY UNIT ST AND SW TORQUE ROTARY UNITS CABLE CONNECTION Compact connector for any orientation of cable connection WEISS APPLICATION SOFTWARE Fast, easy and secure setting

More information

3947 en / b

3947 en / b 3947 en - 06.2006 / b FOOD INDUSTRY Drive systems As a worldwide specialist in drive systems, industrial processes and generators, LEROY-SOMER has supported its customers evolving needs for more than 80

More information

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool FR VARIABLE SPEED DRIVES Regenerative Active Front End icool 4 QUADRANT POWER ELECTRONICS / SD700 SERIES FR SD700FR SERIES goes one step ahead keeping the family unique characteristics. Based on the latest

More information

More Power and Less Fuel with our Electrical Energy Systems. SHARING EXCELLENCE

More Power and Less Fuel with our Electrical Energy Systems. SHARING EXCELLENCE Defense and Security More Power and Less Fuel with our Electrical Energy Systems. SHARING EXCELLENCE Jenoptik ensures all your equipment remains powered up at all times. Modern military vehicles have become

More information

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters Getriebebau NORD GmbH & Co. KG Getriebebau-Nord-Straße 1 22941 Bargteheide, Germany www.nord.com Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters General

More information

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1 Characteristics brushless dc motor 24..48 V - Modbus TCP interface - L = 174 mm - 54:1 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1540.00 USD Main Range of

More information

IMfinity FFB Brake Motors

IMfinity FFB Brake Motors IMfinity FFB Motors NIE Standard Efficiency and IE2/IE3 High Efficiency Variable Speed and Fixed Speed Frame Size 71 to 160 Power 0.25 to 15 kw INTRODUCTION Ranges Fixed speed 4-pole brakes 90 kw FCPL

More information

AC motors. 3/2 Overview

AC motors. 3/2 Overview / Overview / synchronous (induction) motors / forced-ventilated, degree of protection IP / PL motors forced-ventilated, degree of protection IP /4 Selection guides /4 dditional data for PH7 and PL motors

More information