BLOWER MOTORS HA TruckAirParts

Size: px
Start display at page:

Download "BLOWER MOTORS HA TruckAirParts"

Transcription

1 BLOWER MOTORS C500 SERIES C500 w/bergstrom main unit w/double shaft mtr BSM P HB1035 HB1040 HB1050 K PF2646Q RD RD ZGG11645Q C500 All w/main unit w/full RFI/EMI Protection BSM C500 All models w/cw, 1sp motor RD HA C500 w/red Dot A/C, Single Shaft RD RD HA C500, Brute All models w/kysor A/C HA C500 All models w/cw, 2sp motor RD K100, K100C, K100E SERIES K100 K100, K100E all w/bergstrom BSM K100 K100, K100E w/double shaft motor R-4322 HB1085 HB1680 RD K100 All w/double Shaft (Main Unit)203080BSM P HB1035 HB1040 HB1050 K PF2646Q RD RD ZGG11645Q K100C All Cmodels w/double shaft motor P HB1100 PF28103Q PF2865Q RD K100 All models w/cw, 2sp motor BSM P HA1595 RD L700 SERIES L700 w/red Dot A/C (Evaporator Mtr) RD ZGG11270 HB L700 w/red Dot A/C (Condenser Mtr) RD (continued) HA

2 Section I: Trucks BLOWER MOTORS (continued) MID-RANGER All w/red Dot A/C, Double Shaft RD HA1710 ZGG All w/kysor A/C, Double Shaft HA1710 T2000 SERIES All models w/bergstrom w/oe# BSM All models w/bergstrom sleeper unit (cw) BSM All models w/bergstrom main unit (cw) BSM All models w/bergstrom sleeper unit (cw) BSM All w/ccw, 12v, 15" shaft length203126bsm T300-T800 SERIES T300-T800 All w/bergstrom main unit w/dbl shaft motor BSM P HB1035 HB1040 HB1050 K PF2646Q RD RD ZGG11645Q T300-T800 All w/main unit w/full RFI/EMI Protection BSM T600 All T600-T800 w/bergstrom A/C RD HA T400-T800 All models w/double shaft motor HB W900 SERIES W900 All w/bergstrom main unit w/dbl shaft motor BSM P HB1035 HB1040 HB1050 K PF2646Q RD RD ZGG11645Q W900 All w/main unit w/full RFI/EMI Protection BSM W900 All models w/bergstrom A/C RD HA W900 All models w/single shaft motor HA W900 w/red Dot A/C RD SLEEPER All models w/sleeper unit w/oe# BSM All models w/sleeper unit w/oe# BSM All w/sleeper unit w/full RFI/EMI Protection BSM All models w/sleeper unit w/24 volt HA All models w/sleeper unit HA All models w/sleeper unit HA All models w/sleeper unit HA (continued) 66

3 BLOWER MOTORS (continued) All w/bergstrom # 20132P P P P P BSM P BSM P P BSM P P P All w/kysor # All w/paccar # HA All w/red Dot # 73R R R R R R RD RD RD RD All Univ Defroster Fan (12v) HD1015 HG1005 K338-B8 All Univ Defroster Fan (24v) HD

4 Section I: Trucks BLOWER WHEELS (Also See Miscellaneous -Section V: Illustrated) C-500 SERIES C500 All w/bergstrom a/c unit K100, K100C, K100E SERIES K100E Emodels w/bergstrom unit K100 All w/bergstrom a/c unit HC MID-RANGER All w/red Dot A/C RD HC All All w/kysor A/C unit T2000 SERIES T2000 All w/bergstrom a/c main &sleeper unit T2000 All w/bergstrom a/c HC T300-T800 SERIES T300 thru T800 All w/bergstrom a/c unit T300 All T300 Combo w/bergstrom unit T300 w/bergstrom HC T All T600, T800 w/main unit 52480P T All T400, T600, T800 w/kysor Q HC1000 HC1030 W900 SERIES W900 All w/bergstrom a/c unit SLEEPER All w/bergstrom a/c sleeper unit and OE #s HC P W900B w/kysor A/C Q HC1000 HC All w/red Dot A/C sleeper unit HC All w/bergstrom P/N Q P P HC HF All w/red Dot P/N Q Q Q HC HC HC HC HC HC HC HC HC HC RD RD RD RD RD RD RD

5 CHARGE AIR COOLERS HH =Header toheader W =Width T =Thickness (Side to Side) (Top to Bottom) (End to End) Note: Thickness (and other dimensions on some models) may vary due to manufacturer s tooling HH W T INLET OUTLET NOTES OEM # PART NO 2500" 2722" 262" 40" 40" T , W900B (see note *) IE3017, IE3388, K C-1004N w/conv Cab w/3406 Cat (Modine) IE3520, IE3586, K " 2722" 205" 40" 40" 1993 &Older, T400 w/ Conv Style IE3885, IE3470, K093-64, 04C-1002 Hood (Modine); can use 04C-1006N K " 2350" 205" 40" 40" (Modine) IE C " 2762" 205" 40" 40" T , W900 w/cat (Garrett) , C-1006N 2850" 2796" 205" 40" 40" 1993 &Newer T800 (Garrett) , C-1004N 3500" 2381" 205" 40" 40" All w/oe #(Garrett) K093-69, C-1005N , " 17125" 221" - - T300, T400 w/oe# , , 04C-1010N 1E-3622G, " 2213" 205" 40" 40" (G-O/Altec) L A0814,L A1024, 04C-1008N , " 2575" 205" 40" 40" T2000 Ser w/oe (Garrett) C-1007 * NOTE: On models with 15 angle on bottom portion of condenser (cond Ser Nos #K , K ), use 04C-1009N CLUTCHES -CCI/York, Blissfield/Tecumseh MODEL APPLICATION OEM # PART NO All 1gr 6" dia 2wire metripak K KA1530 All 1gr 63/4" dia 1wire plugk All 2gr 6" dia w/diode; 1wire weatherpak KA1410 K K K K K All 2gr 6" dia w/diode 1wire plug K All 2gr 6" dia w/diode &2wire metripack term All 6gr 57/8" dia, 1wire IHC plug KA All 6gr 57/8" dia, 1wire Weatherpak All 6gr 57/8" dia, 2wire Metripak KA1535 All 6gr 57/8" dia, 2wire Metripak All 8gr 53/8" dia, 1wire IHC plug KA All 8gr 57/8" dia, 2wire Metripak KA

6 Section I: Trucks CLUTCHES -Sanden MODEL APPLICATION OEM # PART NO SD508-5H14 2gr 132mm 5-1/4" dia 1wire (4644) KA SD7H15HD 2gr 132mm 5-1/4" dia 1wire (4626,4639) SD7H15HD 2gr 132mm 5-1/4" dia 1wire (4646,4647) SD7H15HD 2gr 125mm 49" dia 2wire (key shft) SD7H15HD 7gr 119mm 46" dia1 wire weatherpak (4665) CLUTCHES -Seltec -TAMA MODEL APPLICATION OEM # PART NO TM15, DKS15CH 1gr, 125mm 49" dia Overhang ABPN ABPN TM15, DKS15CH 2gr, 132mm 5-1/4" dia w/o diode COMPRESSORS Compressor &Clutch Combo -CCI (Climate Control Inc) T600 w/2 gr 6" dia 1wire; w/cat 3406E ET210L-25073C E T800 w/2 gr 6" dia 1wire; w/cummins M11 eng ET210L-25073C E All w/8 gr 6-1/8" 2wire; w/det 60 series eng ET210L-25246C E All w/2 gr 6" dia 2wire; w/cat 3406B (C15) eng ET210L-25237C E All w/6 gr 57/8" 2wire; w/isx eng ET210L-25240C E All w/2 gr 6" dia 1wire; Rotolock Head ER210L-21571C E C All w/2 gr 6" dia 1wire; Tube-O Head C E C K LC1080 LC1140 COMPRESSORS -CCI /Tecumseh All CCI HD w/tube-o ring fitting; w/o serv vlvs ER210L E C LC1105 LC1135 All CCI HD w/rotalock fittings; w/o serv vlvs ER210L E K LC1000 LC1005 All Tecumseh comp w/rotalock fitting E Q LD1000 All Tecumseh comp w/tube-o ring fitting LD E 70

7 COMPRESSORS -Sanden SD7H15 /SD7H15HD (R134a) All w/2 gr 125mm Cum ISC, ISB (4740) w/2 gr 125mm (4713) w/oe# w/2 gr 125mm 49" dia Ear w/vert o ring w/prv (4713) LE w/2 gr 125mm 3406E,M11,N14,C10/C12, S60 (4041, 4426, 4696) F C w/2 gr 125mm 49" Dia 2wire (4041, 4426, 4696) F * C w/2 gr 125mm 2wire clutch (4695) F w/2 gr 125mm S60 (4695) F w/2 gr 125mm 49" 2wire (4426); (4696) F * C w/2 gr 125mm Ear Mount (4627) LE w/2 gr 132mm S60 Direct Mount (4626) LE w/2 gr 132mm Ear mount (4644, 4647, 4664) LE LE1135 w/6 gr 119mm 46" 2wire w/c3406 (4040, 4425, 4492) F F w/6 gr 119mm 46" 2wire (4705) F * F w/6 gr 119mm 46" Dia 2wire (4705) F w/6 gr 125mm w/cum ISM, C10/C12 ( , 4424) F Same as above, Heavy Duty Version S w/7 gr 119mm 46" dia w/vert o ring (4645) LE w/8 gr119mm 3126, 3116 # w/8 gr119mm 3126, 3116 # w/8 gr119mm 46" dia w/cat 3126 (4672) w/8 gr119mm 46" dia w/s60 Series Det (4042, 4759) F w/8 gr119mm 46" w/s60 Series Det (4042, 4432) F Same as above, Heavy Duty Version S w/8 gr119mm 46" C83, B59 (#4667) LE1085, K Same as above, Heavy Duty Version S w/8 gr119mm JDA Head Ear Mount # w/8 gr 125mm 49 dia w/c3406 (4792) F T2000 All w/oe# (4398) F All w/10 gr 126mm Direct Mount (4370) F w/10 gr 126mm Direct Mount (4384) F * C -can be substituted with Seltec # S * can be substituted with Seltec # S SD508/SD510/SD510HD (R12) All SD508 w/2 gr 5-1/4" dia pulley w/oring fitting LE1015 LE1050 LE All SD508 w/1 gr 125mm 49" dia w/oring fitting All SD510 w/2 gr 132mm 5-1/4" dia (5742) LE1000 LE1060 All SD510HD w/1 Var gr 158mm 6-1/4" (9575) LE LE1120 All SD508HD w/1 gr 122mm 4-7/8" dia OH clutch LE1005 LE

8 Section I: Trucks COMPRESSORS -Seltec -TAMA TM16 All w/2 gr 125mm 49 Dia w/o ports (R134a) F S # S Can be used to replace Sanden #4426 and #4696 All w/8 gr 119mm 46" Dia w/o ports (R134a) S # S Can be used to replace Sanden #4705 TM15 All w/1 gr 125mm 49" Dia w/o ports (R134a) w/1 gr 125mm 49" Dia w/ports (R12) F w/1 gr 158mm 6-1/4" w/o ports (R134a) w/1 gr 158mm 6-1/4" w/ports (R12) F w/2 gr 132mm 5-1/4" w/o ports (R134a) w/2 gr 132mm 5-1/4" w/o ports w/diode (R134a) w/2 gr 132mm 5-1/4" w/ports (R12) F w/2 gr 132mm 5-1/4" w/ports w/diode (R12) CONDENSERS MID-RANGER Mid-Ranger All MidRanger w/red Dot A/C RD PA1190 C500 SERIES C500B All models w/red Dot grilldenser w/oe# K C500B Grilledenser 30" x37-1/8" K C500, Brute w/glass Hood K RD K100 SERIES K100CE w/1360 sq in Radiator (32-1/2" x31-3/4") K K100CE w/1360 sq in Radiator (32-1/2" x31-3/4") K K100CE w/1200 cu in Condenser (32-1/2" x27-11/16") K T2000 SERIES T2000 w/radiator mntd cond w/oe# R134a T300-T800 SERIES T300 All models w/radiator mounted cond w/oe# K T400,T600 All models w/front mounted cond (Thermal Comp) K T600,T800 All models w/denspack style radiator mount K T800 w/dual Pass Cab All models w/red Dot grilldenser w/oe# K T600 All models w/grilldenser w/oe# K T600,T800 All models w/radiator mounted w/o sleeper K T450 w/cond in front of Grille (9" x27-1/2") K K T600, T800B w/oe #(Radiator Mount) (Modine) K T800 w/dual Pass Cab Grilledenser w/oe #(Red Dot) K T800 w/dual Pass Cab Grilledenser w/oe #(Red Dot) RD T600, T800 Grilledenser w/oe #(w/30 angle on bottom half) K T600, T800 Grilledenser w/oe #(w/30 angle on bottom half) K T600, T800 Grilledenser w/oe #(w/30 angle on bottom half) K T800 Grilledenser 34-3/8" x41-1/8" K T800 Grilledenser 34-3/8" x41-1/8" RD T600, T600A Radiator Mounted (33-5/8" x35-7/8") w/oe # K (requires re-use ofbracket #K ) T600 w/cond in front of Grille (8-1/2" x30-5/8") K T800 Conv Grilledenser Hood Mounted (26" x37") K T600A Conv Grilledenser 26" x31-1/4" K (continued) T800 w/radiator mtd cond 32-1/2x20-5/8x11/16 w/oe# K

9 CONDENSERS (continued) W900 SERIES W900B All w/radiator mounted cond w/oe# K RD W900L Grilledenser 33-7/8" x35-5/16" K W900 w/1400 sq in Radiator (36-1/8" x40-3/4") K All W900 w/red Dot A/C (Rad Mounted) RD All W900 w/red Dot A/C (Roof Mounted) RD All W900B w/radiator mtd cond 32-1/2x20-5/8x11/16 w/oe# K All All w/red Dot P/N RD All All w/red Dot P/N PB All All w/red Dot P/N RD EVAPORATORS MID-RANGER Mid-Ranger All MidRanger w/red Dot A/CRD NA1145 C-500 SERIES C500 All models Main Evaporator (Bergstrom) BSM BSM NA C500 All models main unit BSM C500 All models w/sleeper unit151321bsm NA C500, Brute All models w/red Dot sleeper unitrd NA C500, Brute All models w/red Dot main evaporatorrd NA1025 K100, K100C, K100E SERIES K100E All models w/bergstrom Evaporator BSM NA K100 Main w/bergstrom unit (o-ring type, can also be used to replace flange type) NA K100 w/bergstrom Evaporator (slave) NA K100E All models w/red Dot main evaporatorrd NA1035 L700 SERIES L700 All models w/red Dot Sleeper unit onlyrd NA1055 T2000 SERIES T2000 All models w/bergstrom Main unit151338bsm T2000 All models w/bergstrom Sleeper unit151339bsm T300-T800 SERIES T300 thru T800 All models Main Evaporator (Bergstrom) BSM BSM NA T300 thru T800 All models w/sleeper unit151321bsm, NA T600 All T600, T800, W900 w/bergstrom A/C BSM T300 thru T800 All models w/oe# NA T600A,T800 w/bergstrom Evaporator 15127P NA T600A,T800 w/bergstrom Evaporator BSM NA T400, T600A, T800 w/kysor A/C (continued) NA

10 Section I: Trucks EVAPORATORS (continued) T300-T800 SERIES (continued) T600A, T800 w/red Dot Evaporator P/N RD NA T600A, T800 w/red Dot Evaporator P/N RD NA T600 All T600, T800, W900 w/kysor A/C NA W900 SERIES W900 All w/bergstrom Main Evaporator w/oe# NA BSM BSM W900 All w/bergstrom Sleeper unit NA BSM W900 w/bergstrom Evaporator 15127P NA W900 w/bergstrom Evaporator BSM NA W900B w/kysor A/C NA W900 w/red Dot Evaporator P/N RD NA W900 w/red Dot Evaporator P/N RD NA W900 w/red Dot Evaporator P/N RD NA All All models w/sleeper unit w/bergstrom A/C NA All All models w/red Dot sleeper unitna FILTERS -IN CAB (Also See Miscellaneous -Section V: Illustrated) All All w/ 7" x10 1/4" x3/4" w/oe# 5X X T2000 All w/ 10" x14" x3/4" w/oe# BSM T450,T00B,T800, All w/ 6-1/4" x8-1/2" x1/2" w/oe# KE0601P W800, W900L FILTER DRIERS MID-RANGER Mid-Ranger All MidRanger w/red Dot A/C RD A Q JA1090 T2000 SERIES T2000 All models w/manifold connection F A JA All All models w/eaton drier w/manifold connection F A F All All w/female inlet &male outlet ports w/oe# K A GD1135 BSM RD All All models w/quick Disconnect Drier w/oe# K A JA2035 (continued) 74

11 FILTER DRIERS (continued) All w/top female switch port, OE#K A JA All (w/o Moisture Indicator) w/oe# A JA Q K K JA All All w/basic drier w/o moisture indicator w/oe# K A P JA All All w/eaton drier w/o trinary switch, top port K A RD JA1070 JA Q All All w/eaton drier w/side mtd low pressure sw K A RD JA1120 JA Q All All w/eaton drier w/top mtd trinary sw K A K RD JA1100 JA Q All w/red Dot P/NJA A All Trinary type w/o SwitchJA A All w/red Dot P/N JA A RD FILTER DRIER MOISTURE INDICATORS -Attaches tooulet of Drier All Moisture indicator w/oe numberk HEATER CORES C-500 SERIES C500 All models w/bergstrom heater core BSM MC C500 All models w/bergstrom (sleeper unit) MC BSM C500 All models w/bergstrom heater (main unit) BSM C500, Brute All models w/red Dot heater core RD MC C500 All models w/red Dot heater core MC L700 SERIES L700 All models w/red Dot main heater RD MC1140 T2000 SERIES T2000 All models Main Unit w/bergstrom heater core BSM T2000 All models w/bergstrom sleeper unit BSM T300-T800 SERIES T300 thru T800 All models w/bergstrom heater core BSM (continued) T400 thru T800 All models w/bergstrom heater core BSM

12 Section I: Trucks HEATER CORES (continued) W900 SERIES W900 All models w/bergstrom heater core BSM BSM MC W900 All models w/bergstrom heater (main unit) BSM MC W900B All models w/bergstrom heater core BSM HEATER VALVES All w/electric Valve (Red-label, long life model BSM MA COE All K100E models w/cable oper valve MA Conv All C500, T , W900 w/90' fitting BSM MA P Conv All C500, T , W900 w/str fitting MA T300 All w/cable opervalve w/bergstrom, core mount MA All models w/air oper valve w/90' elbow MA All models w/air oper valve RD All models w/air oper valve MA All w/cable oper valve (pull to open) MA All w/cable oper valve w/kysor valve MA All w/cable oper valve w/kysor valve All w/cable oper valve w/kysor valve MA All w/cable oper valve w/red Dot valve RD All w/cable oper valve w/red Dot valve RD All w/cable oper valve w/red Dot valve RD All w/cable oper valve w/red Dot valve RD All w/cable oper valve w/bergstrom P/N BSM MB1000 All All All w/cable oper valve w/bergstrom P/N BSM MA1095 All All w/air Operated Valve w/oe P/N K MA1030 K All w/air Operated Valve w/red Dot P/N RD RD MA1050 RD RD MA1020 RD RD MA1030 All w/air Operated Valve w/red Dot P/N RD MA1085 All w/cable Operated Valve w/kysor P/N KB MA MA1015 All w/cable Operated Valve w/red Dot P/N RD MA1065 RD (continued) DA

13 HEATER VALVES (continued) All w/cable Operated Valve w/red Dot P/N RD MA1275 RD MA1060 RD MA1100 MA1045 RD MA1205 All w/cable Operated Valve w/motive Air P/N Q MA Q RELAYS T T2000 All Blower Realy w/oe# CB T2000 All w/mini Relay w/5 terminals, 30 amp 12v CB ALL All w/mini Relay w/5 terminals, 30 amp 12v CB1005 Mini Relay (24v) All w/red Dot A/C Twin Temp Relay (12v) RD CB1015 Bunk Relay (12v) RD CB1010 Mini Relay (12v) RD CB1005 Mini Relay (24v) RD RESISTORS T2000 T2000 w/blwr resistor for main &sleeper unit BSM BSM CA C500,W900B,T, K100E Blower Resistor w/bergstrom A/C CA C500, W900B, T400-T800, Blower Resistor w/bergstrom A/C K100E Blower Resistor w/bergstrom A/C BSM CA C500,T400-T800, W900B, Blower Resistor w/red Dot A/C RD K100E Blower Resistor w/red Dot A/C RD CA C500,W900B,T-Series Blower Resistor w/kysor A/C KB CA

14 Section I: Trucks SWITCHES -BLOWER Includes Circuit Breakers, Fan, Micro, Rocker, Rotary, and Toggle Types T2000 SERIES Bunk Temp control circuit board BSM All bunk control w/temp control potentiometer BSM All cab control w/temp control potentiometer BSM All w/potentiometer w/female conn for cab control BSM All w/bunk control -harness BSM All w/rotary fan switch for cab &bunk control BSM All w/rocker swfor fresh air control (6 terminals) BSM All w/rocker switch for bunk control (6 terminals) BSM All w/rocker switch for cab control (5 terminals) BSM All Blower Switch w/bergstrom A/C BA Micro Switch w/micro switch for cab control BSM Micro Switch w/micro switch w/bergstrom A/C BA C500,K100E,W900B Blower Switch w/bergstrom A/C BA K100 Blower Switch w/red Dot A/C RD BA W900 Blower Switch w/kysor A/C KB BA All Blower Switch w/bergstrom A/C BSM (NOTE: may require modification of lever) BA1055 BA C500, W900B, T , K100 Circuit Breaker (15 amp) CC C500, W900B, T , K100 Circuit Breaker (20 amp) K C500, W900B, T , K100 Circuit Breaker (30 Circuit Breaker (30 K C500, W900B, T , K100 Fan Control Switch (use # pigtail) K C500, K100E, W900B All models w/red Dot A/C RD C500, W900B Blower Switch w/kysor A/C K100,E Blower Switch w/red Dot A/C All All w/red Dot A/C Control (Complete) RD All All w/red Dot Blower Switch w/oe # RD P BA Q Q All All C500, W900 Rocker Switch (3Terminal) RD All All w/red Dot Rocker Switch (5Terminal) RD All All w/red Dot Rocker Switch (6Terminal) RD BA Q K All All C500, K100, W900 Toggle Switch (3Terminal) RD K BE1025 All All w/red Dot Toggle Switch (5Terminal) RD BA1030 All All w/red Dot Toggle Switch (5Terminal) RD BE

15 SWITCHES -PRESSURE Includes Binary, Trinary, High, Low and Sensor Types T T2000 High pressure switch w/o APADS BSM T2000 Llow pressure switch w/o APADS BSM T2000 Temp Circuit Board BSM T2000 Temp Potentiometer (male) BSM ACH49P T2000 Temp Potentiometer (female) BSM T2000 All T2000 w/high pressure switch w/apads BSM C500, K100, T400, T450, T500, T600A, T800, W900 MODELS All Clutch Switch, All w/bergstrom A/C KB P RD BA C500, K100, T400, T450, High Pressure Switch (purple) NC, M10 79-PSD T500-T800, W900B K C500, T400, T450, Low Pressure Switch, Female, NO 86756P T500-T800, W900B BSM BB1030 BB C500, T400, T450, High Pressure Switch, Female, NC BSM T500-T800, W900B BB1025 BB Q C500, T400, T450, Trinary Switch, Female NO (TXV Mounted) K T500-T800, W900B RD BC C500, T400, T450, High Pressure Switch K T500, T600A, T800,W900B K PS PS K100, T400-T800, W900B Trinary Switch, Female, NORD NOTE: Original switch NLA, # is asubstitute RD K BSM 86570P BC All Trinary switch, female, NC RD All Trinary switch, male, NC RD C500, Brute, W900 Low Pressure Switch, malw, (Drier Type) RD BB1000 BSM Q All w/apads High Pressure Switch P All w/apads Low Pressure Switch P All w/apads Module (Non-ECM) P All w/apads Module (ECM Only) P All Trinary Switch, Female NO K RD All Trinary Switch, Female NO (Drier Mounted) RD NOTE: May require use ofnew Trinary RD boot use # BC1005 w/red Dot C T C Circuit Board RD RD

16 Section I: Trucks SWITCHES -THERMOSTATIC MID-RANGER Mid-Ranger All Mid-Ranger w/red Dot A/C RD BD1070 BD Mid-Ranger All Mid-Ranger w/kysor A/C Q BD1105 C-500 SERIES C500 All models w/preset type BSM RD BD C500 All models w/preset type RD C500, Brute All models w/preset type A BD C500 w/cable Type A BD Q RD C500 All models w/cable operated valve T300-T800 SERIES T300,T400,T600,T800 All models w/preset type BSM RD BD T300,T400,T600,T800 All models w/preset type RD P BSM BD Q Q K100, K100C, K100E SERIES K100E All w/red Dot A/C; w/preset type RD A BSM Q BD K100E All models w/preset type RD K100E All K100E models w/preset type A RD BD1070 BD K100 w/cable Type A BD Q T2000 SERIES RD T2000 All models w/preset type BSM RD BD1355 W900 SERIES W900 All models w/preset type BSM RD BD W900 All models w/preset type RD P BSM BD Q Q W900 All models w/preset type A BD1070 BD1075 (continued) 80

17 SWITCHES -THERMOSTATIC (continued) W900 SERIES (continued) W900 All models w/preset type RD W900 w/cable Type A BD Q RD4226 w/kysor System Cable Oper(3 term dble pole type) (Knob Type) BD Q All w/sleeper Bunk Thermostat (w/o Harness and Circuit Board) RD BD1040 VALVES TXV, EXPANSION MID-RANGER Mid-Ranger All models w/block type w/red Dot unit RD A Q EA1210 EA Mid-Ranger All models w/block type w/kysor unit A D Q EA1210 EA1065 C-500 SERIES C500 All models w/block type valve 58590P, A RD Q EA C500 All models w/oring type ext equalized A P D Q EA1020 EA C500 All models w/block type w/male port EA A C500 &Brute All models w/block type -Bergstrom EA A K100, K100C, K100E SERIES K100E All models w/block type valve 58590P, A K100 All models w/block type w/male port BSM A 58950P D K100 All models w/block type valve RD A K100 E All models w/block type valve A D Q EA1210 EA K100 All w/oring type ext equalized w/red Dot unit EA A (continued) 81

18 Section I: Trucks VALVES TXV, EXPANSION (continued) K100, K100C, K100E SERIES (continued) K100 All models w/oring type ext equalized 5638, A 57627P D Q EA1020 EA1230 T2000 SERIES T2000 All models w/flange type valve Main Unit, 2ton BSM A T2000 All w/flange type valve Sleeper Unit, 11/2 ton BSM A T300-T800 SERIES T300,T400,T600,T800 All models w/block type 58590P, A T400,T600,T800 All models w/block type w/male port A RD P EA1090 RD D T400 All models w/block type A T600, T800 All T600, T800 models w/block type RD A T600, T800 All T600, T800 models w/block type w/port A W900 SERIES W900 All models w/block type 58590P, A W900 All models w/block type w/male port RD A P EA1090 RD D W900 &Brute All models w/flare type ext equalized EA A All All Conv w/sleeper unit w/block valve RD A All COE &Conv w/fan clutch solenoid RD All Conv w/sleeper unit w/freon solenoid RD A All models w/air switch w/oe# RD w/kysor External Equalized Valve A (Flare) A w/red Dot External Equalized Valve RD A (Flare) A w/bergstrom Block Type A P A BSM 58590P A w/sleeper A BSM 56089P BSM 85180, 85637, D LA1225 RD RD UE

19 MISCELLANEOUS AIR CYLINDERS, SWITCHES and VALVES All models w/air cylinder w/oe# DA All models w/air pressure sw NC BA All models w/air pressure sw NO BB All models w/air switch w/oe# BA All models w/air switch w/oe# BA All models w/air switch w/oe# BA All models w/air switch w/oe# RD w/bergstrom A/C Air Cylinder (double action) DB Air Cylinder Push Button Switch DB w/red Dot A/C Air Control Switch RD BA1235 K BA1210 RD RD BA1215 w/red Dot A/C Air Cylinder RD DA1010 RD DA1005 RD DA1015 w/red Dot A/C Air Pressure Switch RD BA1225 w/red Dot A/C Air Solenoid (24v) RD BA1330 w/red Dot A/C Air Solenoid (12v) RD MA CONTROL CABLES w/red Dot A/C Control Cable (29") loop/pin hook RD w/red Dot A/C Control Cable (36") loop/knob RD w/red Dot A/C Control Cable (76") loop/pin hook RD w/red Dot A/C Control Cable (76") loop/knob RD w/kysor A/C Control Cable (48") loop ends KB FA1030 KNOBS w/kysor A/C Knob FD w/kysor A/C Knob FD w/red Dot A/C KnobCB w/red Dot A/C KnobFD w/red Dot A/C KnobFD w/red Dot A/C KnobFD

YEAR MODEL APPLICATION O.E.M. # PART NO SERIES All w/flange type motor, heavy duty, w/oe# C1...

YEAR MODEL APPLICATION O.E.M. # PART NO SERIES All w/flange type motor, heavy duty, w/oe# C1... BLOWER MOTORS 2001 1988 2000 All w/flange type motor, heavy duty, w/oe# 1699291-C1 01-0818 2001 1988 2000 All w/hd flange mtr w/wiring harness, prem grade 2500485-C1 01-0817 1986 1977 2010, 2050, All Fleetstar

More information

YEAR MODEL APPLICATION O.E.M. # PART NO. 38,48,49,58,59,69

YEAR MODEL APPLICATION O.E.M. # PART NO. 38,48,49,58,59,69 Section I: Trucks Western Star BLOWER MOTORS YEAR 2011 2005 All... Main Unit (cw) w/oe#... RD58663-0... 01-1610 2004 1996 All... Main and Aux w/red Dot A/C (cw) w/oe#... RD38657-0... 01-1401 2003 1993

More information

13 HVAC. Application Table Blower Motors & Parts for Trucks, Trailers & Buses. Proven, reliable and always innovative.

13 HVAC. Application Table Blower Motors & Parts for Trucks, Trailers & Buses. Proven, reliable and always innovative. Parts for Trucks, Trailers & Buses 13 Proven, reliable and always innovative. offers reliable aftermarket products that are designed and tested to exceed customers expectations regardless of the vehicle

More information

Controls. Electrical & Refrigerant 71R SERIES. Did You Know The EXPANSION VALVE

Controls. Electrical & Refrigerant 71R SERIES. Did You Know The EXPANSION VALVE 71R SERIES 71R SERIES Controls Electrical & Refrigerant Did You Know The EXPANSION VALVE meters refrigerant based upon evaporator heat loads. As the refrigerant gas leaving the evaporator passes through

More information

Controls. Electrical & Refrigerant 71R SERIES. Did You Know. Service Tip 71R SERIES

Controls. Electrical & Refrigerant 71R SERIES. Did You Know. Service Tip 71R SERIES 71R SERIES Controls Electrical & Refrigerant Did You Know The EXPANSION VALVE meters refrigerant based upon evaporator heat loads. As the refrigerant gas leaving the evaporator passes through the valve

More information

71R SERIES. Controls. Electrical & Refrigerant

71R SERIES. Controls. Electrical & Refrigerant 71R SERIES Controls Electrical & Refrigerant Did You Know The expansion valve meters refrigerant based upon evaporator heat loads. As the refrigerant gas leaving the evaporator passes through the valve

More information

Accumulators -See Filter Driers BLOWER MOTORS

Accumulators -See Filter Driers BLOWER MOTORS Chevrolet/GMC Section I: Trucks Accumulators -See Filter Driers BLOWER MOTORS 2005 1999 All w/ A/C (Front auxmtr) (w/wheel) 5246608601-0212 2001 1996 All w&w/o AC (Front A/C) (w/wheel) 5246608001-0212

More information

RELAYS, RESISTORS, &SWITCHES (11- )

RELAYS, RESISTORS, &SWITCHES (11- ) Switches Section V: Table of Contents RELAYS, RESISTORS, &SWITCHES (11- ) A/C ON/OFF SWITCHES (See es)... 450 AIR OPERATED (See Misc. Section) (19- )... 540-541 AMBIENT TEMP SWITCH (See Pressure Switches)...

More information

Controls. Electrical & Refrigerant 71R SERIES

Controls. Electrical & Refrigerant 71R SERIES 71R SERIES Controls Electrical & Refrigerant Did You Know The EXPANSION VALVE meters refrigerant based upon evaporator heat loads. As the refrigerant gas leaving the evaporator passes through the valve

More information

Controls. Electrical & Refrigerant 71R SERIES

Controls. Electrical & Refrigerant 71R SERIES 71R SERIES Controls Electrical & Refrigerant Did You Know The EXPANSION VALVE meters refrigerant based upon evaporator heat loads. As the refrigerant gas leaving the evaporator passes through the valve

More information

Basic Information EVAPORATORS EVAPORATORS. EvaporatorS Illustrations Specifications...352

Basic Information EVAPORATORS EVAPORATORS. EvaporatorS Illustrations Specifications...352 Table of Contents Basic Information The A/C Evaporator is located on the low pressure side of the a/c system. It is usually mounted inside the cab under the dash panel. The evaporator receives the refrigerant

More information

SWITCHES. MISCELLANEOUS Air Control Switches Air Cylinders Louvers and Diffusers Switch Control Knobs

SWITCHES. MISCELLANEOUS Air Control Switches Air Cylinders Louvers and Diffusers Switch Control Knobs Table of Contents AIR, CYCLING, CUT-OFF, SENSORS, TEMPERATURE, and TRANSDUCERS Pressure Specifications Chart... 481 AIR OPERATED... 463 AIR SENSING... 464 APADS... 496 BINARY/TRINARY... 489 BLOWER - Rocker,

More information

RoadChoice.com HVAC CATALOG

RoadChoice.com HVAC CATALOG RoadChoice.com HVAC CATALOG 2017 Table of Contents POPULAR TRUCK APPLICATIONS Freightliner...................................................... 3 Kenworth...5 Mack...7 Navistar...9 Peterbilt.......................................................

More information

SERVICE VALVES. Selecting the Correct Service Valves COMPRESSOR PARTS

SERVICE VALVES. Selecting the Correct Service Valves COMPRESSOR PARTS COMPRESSOR SERVICE VALVES Table of Contents Selecting the Correct Service Valves 1. Determine Type of Fitting on Compressor Head: HEAD TYPES O Ring 3/4 x 7/8 Tube-O 1-14 Rotalock, or Flange 2. Determine

More information

A/C SALES and PRODUCT TRAINING

A/C SALES and PRODUCT TRAINING A/C SALES and PRODUCT TRAG 1 TECHNICAL OVERVIEW SYSTEM IDENTIFICATION 5 PART EXPANSION VALVE SYSTEM HOT HIGH PRESSURE GAS LOW PRESSURE GAS (SUCTION SIDE) COLD LOW PRESSURE GAS EXPANSION VALVE OUTSIDE AIR

More information

ELECTRICAL PARTS. 3 SPEED ROTARY LONG SHANK WITH NUT PART No: SPEED ROTARY WITH RESISTOR 24v. PART No: PART No:

ELECTRICAL PARTS. 3 SPEED ROTARY LONG SHANK WITH NUT PART No: SPEED ROTARY WITH RESISTOR 24v. PART No: PART No: SWITCHES 3 SPEED ROTARY WITH NUT PART No: 5010-10000 3 SPEED ROTARY LONG SHANK WITH NUT PART No: 5010-10010 CONNECTING BLOCK PART No: 500-10010 3 SPEED ROTARY WITH RESISTOR 12v 3 SPEED ROTARY WITH RESISTOR

More information

Section V: Table of Contents

Section V: Table of Contents Section V: Table of Contents Basic Evaporator Information The A/C Evaporator is located on the low pressure side of the a/c system. It is usually mounted inside the cab under the dash panel. The evaporator

More information

Tractor Supply Ltd. WE RE MORE THAN USED PARTS HY-CAPACITY. Air Conditioning. Quick Reference Guide.

Tractor Supply Ltd. WE RE MORE THAN USED PARTS HY-CAPACITY. Air Conditioning. Quick Reference Guide. Tractor Supply Ltd. WE RE MORE THAN USED PARTS HY-CAPACITY Air Conditioning Quick Reference Guide www.fawcett.cc www.fawcett.cc HY-CAPACITY All-Makes Air Conditioning can help your business Service multiple

More information

Section V: Illustrated

Section V: Illustrated Switches Relays 11-3037 12volt -w/o Diode 30-40 Amp 11-3039 24volt -w/o Diode 15-20 Amp RED DOT A/C VF4-65F11-12V, VF4A-65H11-24V 5Terminal, Weather Seal 11-3040 Relay, 70Amp Carrier/Transair 10-00328-00;

More information

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS RED DOT UNITS CONDENSERS HEATERS UNDERDASH DUCTABLES BACKWALL HEADLINERS ROOFTOP R-4500 Rooftop (45,000 BTU) FIRETRUCKS CRASH & RESCUE VEHICLES DUAL EVAPORATORS The R-4500 offers amazing performance for

More information

R-4122 Sleeper Heater/ Air Conditioner Unit. R-2550 Heater/Air Conditioner Unit RED DOT UNITS HEATER-A/C RESCUE VEHICLES

R-4122 Sleeper Heater/ Air Conditioner Unit. R-2550 Heater/Air Conditioner Unit RED DOT UNITS HEATER-A/C RESCUE VEHICLES R-2550 Heater/Air Conditioner Unit RESCUE VEHICLES The R-2550 is specifically designed for ambulances and other lighter-duty vehicles with large interior spaces to heat and cool quickly. R-2550 SPECIFICATIONS

More information

R-6160 Rooftop Condenser (24,000 BTU) R-4500 Rooftop Condenser (45,000 BTU) RED DOT UNITS CONDENSERS. Crash/Fire/Rescue

R-6160 Rooftop Condenser (24,000 BTU) R-4500 Rooftop Condenser (45,000 BTU) RED DOT UNITS CONDENSERS. Crash/Fire/Rescue RED DOT UNITS R-4500 Rooftop Condenser (45,000 BTU) Crash/Fire/Rescue Dual Evaporators Our largest power condenser, the R-4500 is a dual-fan unit with the capacity needed for high-performance evaporators

More information

75R SERIES BLISSFIELD (TECUMSEH), TCCI (YORK) COMPRESSOR CLUTCHES. CLUTCH SPECIFICATIONS Clutches are sorted by increasing size of Pulley Diameter [A]

75R SERIES BLISSFIELD (TECUMSEH), TCCI (YORK) COMPRESSOR CLUTCHES. CLUTCH SPECIFICATIONS Clutches are sorted by increasing size of Pulley Diameter [A] BLISSFIELD (TECUMSEH), TCCI (YORK) COMPRESSOR CLUTCHES C B D A If part number on clutch being replaced cannot be read use following procedure to determine required clutch part number. 1. Determine if clutch

More information

R134a Compressors SD 5 10 HD SD 7 H 15 HD

R134a Compressors SD 5 10 HD SD 7 H 15 HD SANDEN Compressor Identification R12 Compressors Sanden Number of Cylinders Approx. Displacement (cu.in.) Heavy Duty Clutch R134a Compressors SD 5 10 HD SD 7 H 15 HD Sanden Number of Cylinders Port Location

More information

Table of Contents. Basic Information (Cores)

Table of Contents. Basic Information (Cores) Table of Contents Basic Information (Cores) The A/C CONDENSER Is located on the high pressure side of the a/c system. It is mounted directly in front of the radiator where it can receive air flow created

More information

Identification Tag (cannot be used for ordering purposes) Part Number Label (identifies mfg. part number of complete assy.)

Identification Tag (cannot be used for ordering purposes) Part Number Label (identifies mfg. part number of complete assy.) Compressors - Seltec Section V: Illustrated Identification Tag (cannot be used for ordering purposes) (identifies specifications only) Type and Model Refrigerant Type Lubricant Type Seltec Body Number

More information

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS CONDENSERS

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS CONDENSERS RED DOT UNITS R-4500 Rooftop (45,000 BTU) FIRETRUCKS CRASH & RESCUE VEHICLES DUAL EVAPORATORS The R-4500 offers amazing performance for a light weight dual fan power condenser. Its high capacity gives

More information

SWITCHES SWITCHES SWITCHES. AIR, CYCLING, CUT-OFF, SENSORS, TEMPERATURE, and TRANSDUCERS Miscellaneous Specifications Chart

SWITCHES SWITCHES SWITCHES. AIR, CYCLING, CUT-OFF, SENSORS, TEMPERATURE, and TRANSDUCERS Miscellaneous Specifications Chart AIR, CYCLING, CUT-OFF, SENSORS, TEMPERATURE, and TRANSDUCERS Miscellaneous Specifications Chart... 567 ACTUATORS... 473, 556 AIR OPERATED... 548 AIR SENSING... 549 APADS... 588 MISCELLANEOUS Air Control

More information

REPLACEMENT PARTS ILLUSTRATION

REPLACEMENT PARTS ILLUSTRATION REPLACEMENT PARTS ILLUSTRATION Customer Service 1-817-293-3331 IMPORTANT RESTRICTION THE INFORMATION CONTAINED HEREIN IS FOR EXCLUSIVE USE OF THE MANUFACTURERS CUSTOMERS. NEITHER THE SHEETS NOR THE INFORMA-

More information

3ROUP 24 - AIR CONDITIONING

3ROUP 24 - AIR CONDITIONING AIR CONDITIONING 1962 PASSENGER CAR PARTS CATALOG Page 24-1 3ROUP 24 - AIR CONDITIONING LOUVER AND BEZEL SCREEN 24-28-79 KNOB 24-24-20 HOUSiNG\ 24-28-75 //RETAINER 24-28-76 / R F 7 F, 0 / L 24-28-78 \

More information

XV. Parts. Mobile Climate Control 303

XV. Parts. Mobile Climate Control 303 XV. Parts Mobile Climate Control 303 MCC Reference Manual 2014 XV.1. Valves and O-Rings Heater Solenoids Valve 26-0348 26-0330 26-0194 Heater solenoid valve 24V 3/4 3 way 26-0348 Heater solenoid valve

More information

SWITCHES SWITCHES. Control Switches SWITCHES. Pressure Specifications Chart , 528

SWITCHES SWITCHES. Control Switches SWITCHES. Pressure Specifications Chart , 528 Air, Cycling, Cut-Off, SENSORS, temperature, and TRANSDUCERS Pressure Specifications Chart... 511, 528 Air operated Switches... 510 Air Sensing Switches... 545 Apads switches... 551 Binary/Trinary... 537,

More information

On-Road OEM Applications

On-Road OEM Applications On-Road OEM Applications CHEVROLET/GMC BLOWER, FAN MOTOR Topkick/Kodiak 40-95 Series 1970-99 Blower - defrost fan, universal - Main unit 4960477 RD-5-11850-0P 73R9102 BLOWER MOTOR Astro, Titan (Cab Over)

More information

UNIVERSAL SANDEN MANUFACTURER # RANSHU NUMBER PRICE DESCRIPTION MANUFACTURER # RANSHU NUMBER PRICE DESCRIPTION

UNIVERSAL SANDEN MANUFACTURER # RANSHU NUMBER PRICE DESCRIPTION MANUFACTURER # RANSHU NUMBER PRICE DESCRIPTION SANDEN MANUFACTURER # RANSHU NUMBER PRICE DESCRIPTION 4508 14-SD4508NC $630.00 SD5H14 10 GROOVE POLY V-ORING 4509 14-SD4509NC $630.00 SD5H14 5.25" 2 A GROOVE V-ORING 4510 14-SD4510NC $630.00 SDH14 5.25"

More information

Parts List, Charging Chart, Wiring Diagrams

Parts List, Charging Chart, Wiring Diagrams Parts List, Charging Chart, Wiring Diagrams PHN5 24-60 SERIES 1 Phase R-410A PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST 2-5 PARTS DRAWING 6-17 CHARGING CHART 18 WIRING DIAGRAMS 19-21 Printed

More information

25 Off Use code: COUPON-RTACCOMP25 Valid March 1 31, Off Use code: COUPON-RTACCOND20 Valid March 1 31, 2019.

25 Off Use code: COUPON-RTACCOMP25 Valid March 1 31, Off Use code: COUPON-RTACCOND20 Valid March 1 31, 2019. HVAC parts for all makes and models. Any Rig Tough Compressor $ 25 Off Use code: COUPON-RTACCOMP25 Valid March 1 31, 2019. Any Rig Tough Condenser $ 20 Off Use code: COUPON-RTACCOND20 Valid March 1 31,

More information

R-8230 Underdash Heater/Air Conditioner Unit

R-8230 Underdash Heater/Air Conditioner Unit INTERNATIONAL R-8230 Underdash Heater/Air Conditioner Unit NAVISTAR INTERNATIONAL S, 4000, 7000, and 8000 SERIES TRUCKS, 1983 1994 The R-8230 exceeds the performance of the original system and has styling

More information

PART NO. SAL025 REVISED: 7/18/2013. Supplying All School Bus Manufacturers

PART NO. SAL025 REVISED: 7/18/2013. Supplying All School Bus Manufacturers SCHOOL BUS A/C CATALOG PART NO. SAL025 REVISED: 7/18/2013 Supplying All School Bus Manufacturers 1-800-831-6301 www.sunairusa.com WARRANTY STATEMENT Sunair Products warrants the products it offers, to

More information

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date: MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER 15-24 Date: 11-19-2015 SUBJECT: MODELS/ S/N AFFECTED: To ADVISE MOONEY OWNERS/OPERATORS of the LYCOMING Service Instruction

More information

& 76 CHEVROLET NOVA HEATER ONLY

& 76 CHEVROLET NOVA HEATER ONLY specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1969-74 & 76 CHEVROLET NOVA HEATER ONLY CONTROL & OPERATING INSTRUCTIONS The controls on

More information

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit. 1.1 PRODUCT APPLICATION INFORMATION WORKSEET The following information will aid you in selecting the correct magneto, upgrade kit, or ignition harness: 1. Engine Manufacturer 2. Engine Model Number 3.

More information

Mounting & Drive Kit Applications

Mounting & Drive Kit Applications KIT APPLICATIONS Air Conditioning & Heating Replacement Parts Mounting & Drive Engine Application Data... 6 Autocar Conventional Series...6 Chevrolet Tiltmaster...6 Chevrolet C Series Conventional...6

More information

77R SERIES. Condensers. Passive & Powered

77R SERIES. Condensers. Passive & Powered 77R SERIES Condensers Passive & Powered Did You Know The presence of dust, bugs and debris on the face of the condenser fin and tubes will create a thermo-barrier. In turn, the condenser s ability to dissipate

More information

Parts List, Charging Chart, Wiring Diagram

Parts List, Charging Chart, Wiring Diagram Parts List, Charging Chart, Wiring Diagram PAD3 30-60A SERIES 3 Phase R-410A PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST 2-8 PARTS DRAWING 9-19 CHARGING CHART 20 WIRING DIAGRAM 21-22 Printed

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

77R SERIES. Condensers. Passive & Powered. Did You Know The presence of dust, bugs and debris

77R SERIES. Condensers. Passive & Powered. Did You Know The presence of dust, bugs and debris 77R SERIES 77R SERIES Condensers Passive & Powered Did You Know The presence of dust, bugs and debris tubes will create a thermo-barrier. In turn, the condenser s ability to dissipate heat is reduced resulting

More information

A/C SYSTEM SPECIFICATIONS

A/C SYSTEM SPECIFICATIONS A/C SYSTEM SPECIFICATIONS SPECIFICATIONS Application Specification Compressor Type Matsushita Matsushita Rotary Sanden Sanden Scroll Compressor Belt Deflection (1) Used 5/16-7/16" (8-9.5 mm) New 9/32-5/16"

More information

77R SERIES. Condensers. Passive & Powered

77R SERIES. Condensers. Passive & Powered 77R SERIES Condensers Passive & Powered Did You Know The presence of dust, bugs and debris on the face of the condenser fin and tubes will create a thermo-barrier. In turn, the condenser s ability to dissipate

More information

Millennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP

Millennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP Millennium TM Rotary Screw Liquid Chillers renewal parts Supersedes: 160.80-RP1 (1099) Form 160.80-RP1 (710) Model YS BA CB S0 thru YS FA FB S5 (Style E) 100 thru 675 Tons (315 thru 2375 kw) 00202VIP R-22

More information

READ COMPLETELY BEFORE QUOTING REPOWER

READ COMPLETELY BEFORE QUOTING REPOWER ATTENTION READ COMPLETELY BEFORE QUOTING REPOWER As in any REPOWER, experience has shown that a piece of equipment designed for older Tier 0 or Tier model engines almost always has trade-offs and compromises

More information

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL Centrifugal Chiller PE046, PE047, PE048, PE050 PEH046-050 PF083, PF096, PF105, PF116 PH046-050 PHH046-050 PL-906-49 Unit ASSY. - Labels / 1987 to Present Unit ASSY. - Labels / 1987 to Present No. Index

More information

V 40/30A. Heavy duty type, 12 amp, thread

V 40/30A. Heavy duty type, 12 amp, thread Relays 505 V 40/30A 509 4V 40A 50074 V 40/30A 50 Socket for 505 and 509 Resistors 5036 V (0.4 +0.4 ) 300 F (50 C) meltfuse 5056 4V (.8 +.0 ) 5055 4V (0.8 +.8 ) 500 V (0.5 +.3 ) 5039 V (0.35 +.5 ) 50095

More information

77R SERIES. Condensers. Passive & Powered

77R SERIES. Condensers. Passive & Powered 77R SERIES Condensers Passive & Powered Did You Know The presence of dust, bugs and debris on the face of the condenser fin and tubes will create a thermo-barrier. In turn, the condenser s ability to dissipate

More information

CONDENSERS BASIC INFORMATION CONDENSERS. CONDENSER Specifications Chart Visual Illustrations Section MULTI-FLOW RETROFIT CONDENSERS...

CONDENSERS BASIC INFORMATION CONDENSERS. CONDENSER Specifications Chart Visual Illustrations Section MULTI-FLOW RETROFIT CONDENSERS... Table of Contents BASIC INFORMATION The A/C Condenser Is located on the high pressure side of the A/C system. It is mounted directly in front of the radiator where it can receive air flow created by the

More information

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved 652 Oliver Street Williamsport, PA. 17701 U.S.A. Telephone +1 (800) 258-3279 U.S. and Canada (Toll Free) Telephone +1 (570) 323-6181 (Direct) Facsimile +1 (570) 327-7101 Email Technicalsupport@lycoming.com

More information

HEATER CORES. Basic Information

HEATER CORES. Basic Information Table of Contents Basic Information The HEATER CORE is usually located inside the cab under the dash. It is connected to the engines heater hoses. As hot engine coolant flows through its coils or tubes;

More information

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax 652 Oliver Street Williamsport, PA. 17701 U.S.A. Tel. 570 323 6181 Fax. 570 327 7101 www.lycoming.com SERVICE INSTRUCTION DATE: March 8, 2012 Service Instruction No. 1098H (Supersedes Service Instruction

More information

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! F.A.A.-P.M.A. MODEL 1U128A AND 1U128B REVISION 17 February 21, 2002 VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! The following information applies to all installations

More information

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved DATE: May 19, 2000 (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved SUBJECT: MODELS AFFECTED: TIME OF COMPLIANCE: Approved Slick Magnetos on Textron Lycoming Engines See

More information

Dealer Notice MTSDNC

Dealer Notice MTSDNC To: All RigMaster Dealers Re: Part Changes and the Recommended Stock List In a continuous effort to improve the RigMaster product there have been many engineering changes made to the RigMaster T4 unit.

More information

TROUBLE SHOOTING CHART

TROUBLE SHOOTING CHART Section V: Illustrated York Style, Blissfield/Tecumseh TROUBLE SHOOTING CHART PROBLEM DIAGNOSIS CAUSE AND REMEDY SYMPTOM AND INSPECTION REPAIR OR REPLACE IMPROPER COOLING - (No unusual compressor noise)

More information

FRT15B3JQ0 FRT15B3JW0 FRT15B3JZ0

FRT15B3JQ0 FRT15B3JW0 FRT15B3JZ0 Product No. Q0 W0 Z0 Series R134a R134a R134a Color bisque (right) white (right) white (left) Volts 115 115 115 Wiring Diagram 241582401 241582401 241582401 Owner's Guide 241857201 241857201 241857201

More information

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion. 652 Oliver Street Williamsport, PA. 17701 U.S.A. Telephone +1 (800) 258-3279 U.S. and Canada (Toll Free) Telephone +1 (570) 323-6181 (Direct) Facsimile +1 (570) 327-7101 Email Technicalsupport@lycoming.com

More information

Parts List, Wiring Diagrams

Parts List, Wiring Diagrams Parts List, Wiring Diagrams PAS180-300 SERIES PACKAGE GAS ELECTRIC UNITS TABLE OF CONTENTS PARTS LIST----------- 2-16 PARTS DRAWING - - - - - 17-28 WIRING DIAGRAMS - - - 29-52 Printed in U.S.A. 5/22/08

More information

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON Only for internal use Stars or starlets? Competitor overview switching devices sirius IN COMPARISON Who are the real stars? The comparison. Under ideal conditions, the human eye can make-out approximately

More information

34.0 EMF SERIES FLAKERS EMF 450, EMF800, EMF1106 AIR, WATER AND REMOTE

34.0 EMF SERIES FLAKERS EMF 450, EMF800, EMF1106 AIR, WATER AND REMOTE AIR COOLED 5 Air Condenser 9141002-01 AC X 5 Air Condenser 9141017-01 AC X 5 Air Condenser 9141046-01 AC X 10 Fan Blade 9131133-02 AC 10 Fan Blade 9131133-01 AC X 10 Fan Blade 9131204-01 AC X 15 Fan Motor

More information

SERVICE PARTS for MCC XCELSIOR SERIES T -367PL REV. 02/ Mobile Climate Control

SERVICE PARTS for MCC XCELSIOR SERIES T -367PL REV. 02/ Mobile Climate Control T--367PL Manual SERVICE PARTS for MCC XCELSIOR SERIES 50-2104 T -367PL REV. 02/2015 PARAGRAPH NUMBER TABLE OF CONTENTS INTRODUCTION... II MODEL/SERIAL NUMBER PLATE LOCATION... II MODEL CHART... II ORDERING

More information

34.0 EMF SERIES FLAKERS EMF 450, EMF800, EMF1106 AIR, WATER AND REMOTE

34.0 EMF SERIES FLAKERS EMF 450, EMF800, EMF1106 AIR, WATER AND REMOTE Shaded Code indicates updated information AIR COOLED 5 Air Condenser 9141002-01 X 5 Air Condenser 9141017-01 X 5 Air Condenser 9141046-01 X 10 Fan Blade 9131133-02 10 Fan Blade 9131133-01 X 10 Fan Blade

More information

LYCOMING CYLINDER PRICING

LYCOMING CYLINDER PRICING SHIPPING: 2415 EMBARCADERO WAY, PALO ALTO, CA 94303 MAILING: P.O. BOX 50608, PALO ALTO, CA. 94303-0608 Phone: 650-354-1399 Fax: 650-354-1395 LYCOMING CYLINDER PRICING CYLINDER PRICING ENGINE MODEL: O-235

More information

MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM SECTION 7C MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit

More information

140P-2674 AND LATER 175P-4023 AND LATER 250P-2783 AND LATER

140P-2674 AND LATER 175P-4023 AND LATER 250P-2783 AND LATER SERIAL NUMBERS 140P-2674 AND LATER 175P-4023 AND LATER 250P-2783 AND LATER FORM WC5310 3/95 (Rev. 9/97, 6/99, 1/00, 2/00) Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380 TABLE OF CONTENTS VIEW

More information

Program IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT

Program IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT Performance A/C International A N AV I S TA R C O M PA N Y Program IV: ProStar TM Study Guide TMT-160701 Series Study Guide Performance A/C Program IV: International ProStar Series TMT-160701 2007 International

More information

Table of Contents Accumulators RECEIVER DRIERS

Table of Contents Accumulators RECEIVER DRIERS Table of Contents Accumulators RECEIVER DRIERS Basic Information Receiver Driers, Accumulators and In-Line Filters are canisters used to filter debris and remove moisture to protect the a/c system. Various

More information

F150/250 all w/oe#... Blower Motor w/wheel w/oe#... F85Z-19805CA A without wheel

F150/250 all w/oe#... Blower Motor w/wheel w/oe#... F85Z-19805CA A without wheel Ford / Sterling Truck Includes A-AT, L, M Series Section I: Trucks BLOWER MOTORS Cargo, CF/CFT 600-800 1991 1989 All... w/factory A/C, F.N.H. Engine, CCW... E9TF-19805BC... 01-3003 1990 1986 All... w/ford

More information

77R SERIES. Condensers. Passive & Powered

77R SERIES. Condensers. Passive & Powered 77R SERIES Condensers Passive & Powered Did You Know The presence of dust, bugs and debris on the face of the condenser fin and tubes will create a thermo-barrier. In turn, the condenser s ability to dissipate

More information

Receiver Driers. Accessories

Receiver Driers. Accessories 74R SERIES Receiver Driers Accessories Did You Know The primary function of a receiver drier is to remove moisture from the A/C system. Under normal operating conditions the drier canister should be warm

More information

Item MF CMF EMF LP Code Part Description Part # GRP

Item MF CMF EMF LP Code Part Description Part # GRP MF SERIES FLAKERS MF2006-CMF2306-EMF2306 AIR, WATER & REMOTE Item MF CMF EMF LP Code Part Description Part # GRP 2006 2306 2306 2306 AIR COOLED 5 Air Condenser 9141056-01 AC X X X 10 Fan Blade 9131053-01

More information

Campaign no.: Date: July 13, 2006 Subject: Fluctuating and Sticking No Speedometer Needle

Campaign no.: Date: July 13, 2006 Subject: Fluctuating and Sticking No Speedometer Needle Campaign no.: 2006-0006 2007-0002 Date: July 13, 2006 Subject: Fluctuating and Sticking No. 2007-2 Speedometer Needle YEAR MODEL MODEL NUMBER SERIAL NUMBER 2006-2007 Outlander 650 and 800 All Refer to

More information

H:\SC218\17_Ersatzteile\Spare Parts SC 218.doc

H:\SC218\17_Ersatzteile\Spare Parts SC 218.doc page 1 / 14 Version: V2016-07 2,2a 3 4 5 6 7 8 13 Air bleeder 9 12 Flow switch 1 10 11,11a page 2 / 14 Version: V2016-07 description electrical item 1 ball valve (drain and fillin valve red handle bar)

More information

FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM SECTION 7D FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM FATC (Full Automatic Temperature Control) is full automatic heater and airconditioning system that detects

More information

SERVICE & OWNER S MANUAL

SERVICE & OWNER S MANUAL 1 of 10 SERVICE & OWNER S MANUAL Product Specifications 25 x 36 x 7 Weight: 47 lbs. Air Flow: 260 CFM Air Conditioner p/n: 1ACUNIT-G1 Fits with Curtis Roof Kit: Contact Curtis for Details. Fits with Curtis

More information

CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO FORM (June 2001)

CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO FORM (June 2001) CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS HQC135 HQC200 ML-124045 ML-124046 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43009 (June 2001) 28 PRB1 PRB2 PRB3 6 27 11

More information

INSTRUCTION PACKET TIER 3 ENGINE REPOWER KIT 762B SCRAPER

INSTRUCTION PACKET TIER 3 ENGINE REPOWER KIT 762B SCRAPER PLEASE READ ALL INSTRUCTIONS THOROUGHLY BEFORE STARTING REPOWER INSTRUCTION PACKET TIER 3 ENGINE REPOWER KIT 762B SCRAPER WWW.BELLPOWER.COM Engine Prep 762B 1. Install (1) BELL1033 engine f/w adapter ring

More information

Discharge oil capacity cm Discharge oil capacity. Max. stroke volume on retraction Remarks.

Discharge oil capacity cm Discharge oil capacity. Max. stroke volume on retraction Remarks. 2 High Power Systems High Power Systems 3 Working pneumatic pressure range MPa 0.2 to 0.2 to 0.7 0.2 to 0.7 0.2 to 0.7 0.2 to 0.7 Boosting ratio Theoretical output oil pressure at max. working pneumatic

More information

Receiver Driers. Accessories

Receiver Driers. Accessories Receiver Driers Accessories Did You Know The primary function of a receiver drier is to remove moisture from the A/C system. Under normal operating conditions the drier canister should be warm to the touch.

More information

Low Voltage 3-Phase Induction Motors. Range 0.18kW to 670kW

Low Voltage 3-Phase Induction Motors. Range 0.18kW to 670kW Low Voltage 3-Phase Induction Motors Range 0.18kW to 670kW Totally Enclosed Fan-Cooled Cast Iron Series Contents page page PRODUCT DETAILS General Information 2 Electrical Design and Standards Altitude

More information

PRODUCT GROUP WEIGHT MIN ORDER

PRODUCT GROUP WEIGHT MIN ORDER L111280010 070115629G T5-TOUAREG OIL LEVEL DIPSTICK PLASTIC 200 20 L111300010 7H0145980D- 7H0145980F TRANSPORTER T5 TURBO S 513 1 2,5 L111300020 7H0145980E- 7H0145980C- 7H0145980G- TRANSPORTER T5- CADDY

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI Application Dimensional drawings Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +550 C. Design Two support rings with replaceable orifice disk

More information

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109 VALVE CATALOG MAIN INDEX RELEASED DATE: JUNE 03. QUICK SELECTION GUIDE Page SOLENOID OPERATED DIRECTIONAL CONTROLS (See ENGINEERING DATA for coil specs) Page 7 MECHANICAL DIRECTIONAL CONTROLS Page 5 PRESSURE

More information

Item MF CMF EMF LP Code Part Description Part #

Item MF CMF EMF LP Code Part Description Part # 32.0 MF SERIES FLAKERS MF2006-CMF2306-EMF2306 AIR, WATER & REMOTE Item MF CMF EMF LP Code Part Description Part # 2006 2306 2306 2306 AIR COOLED 5 Air Condenser 9141056-01 X X X 10 Fan Blade 9131053-01

More information

Replacment Parts. Red Dot. Bus HVAC Parts SCHOOL AND TRANSIT BUSES

Replacment Parts. Red Dot. Bus HVAC Parts SCHOOL AND TRANSIT BUSES H V A C Y T E M C O M P O N E N T Red ot Replacment Parts CHOOL AN TRANIT BUE Bus HVAC Parts PAGE 2 CHOOL AN TRANIT BUE REPLACEMENT PART Bus HVAC Parts Here s a comprehensive list of everything you ll

More information

1961 PASSENGER CAR PARTS CATALOG Page 24-1 GROUP 24 - AIR CONDITIONING

1961 PASSENGER CAR PARTS CATALOG Page 24-1 GROUP 24 - AIR CONDITIONING AIR CONDITIONING 1961 PASSENGER CAR PARTS CATALOG Page 24-1 GROUP 24 - AIR CONDITIONING BOLT.VALVE 24-25-107 GASKET 24-25-110 PARTS INDICATED SY NAME ONLY - ORDER BY DESCRIPTION GASKET 24-25-110 HEAD 24-25-4

More information

Jeep Wrangler 4.0 Liter TJ Jeep Wrangler 2.5 Liter TJ Installation instructions

Jeep Wrangler 4.0 Liter TJ Jeep Wrangler 2.5 Liter TJ Installation instructions TM www.jeepair.com 1999 Jeep Wrangler 4.0 Liter TJ 1999-2001 Jeep Wrangler 2.5 Liter TJ Installation instructions Kit Information After 1994 every vehicle was designed for R134a refrigerant. The Jeep kit

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

Limit Switches and Safety

Limit Switches and Safety and Safety Introduction Overview 3SE5 23., 3SE5 21. 3SF1 2.4 3SE5 24., 3SF1 244 3SE5 13., 3SE5 11., 3SF1 114 3SE5 12., 3SF1 124 3SE5 16. 3SE5 232, 3SE5 212, 3SF1 2.4 3SE5 132, 3SE5 112, 3SF1 1.4 Position

More information

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS SURE JET VACUUM BASE SJVB SURE JET VACUUM BASE SJDB-EXT Parts Manual SJ_EFS-PARTSBOOK051507reva 1 TABLE OF CONTENTS ENVELOPE FINISHING SYSTEM- SURE JET EFS-SURE

More information

RED DOT UNITS. Condensers CONDENSERS PAGE 59

RED DOT UNITS. Condensers CONDENSERS PAGE 59 CONDENSERS RED DOT UNITS Condensers PAGE 59 R-4500 Rooftop Condenser (45,000 BTU) FIRETRUCKS CRASH & RESCUE VEHICLES DUAL EVAPORATORS The R-4500 offers amazing performance for a light weight dual fan power

More information

CMF SERIES FLAKERS CMF450-CMF800-CMF1106 AIR, WATER AND REMOTE

CMF SERIES FLAKERS CMF450-CMF800-CMF1106 AIR, WATER AND REMOTE CMF SERIES FLAKERS CMF450-CMF800-CMF1106 AIR, WATER AND REMOTE Item CMF CMF CMF Code Part Description Part No. GRP 450 800 1106 Shaded Item Code indicates updated information AIR COOLED 5 Air Condenser

More information

COMPRESSORS (03- ) Basic Compressor Information. BLISSFIELD (Tecumseh) see T/CCI

COMPRESSORS (03- ) Basic Compressor Information. BLISSFIELD (Tecumseh) see T/CCI Section V: Table of Contents Compressors Basic Compressor Information There are many different makes of compressors used in our marketplace. Regardless of manufacture and design, all compressors operate

More information