WIREMOLD Wallduct Raceway Systems

Size: px
Start display at page:

Download "WIREMOLD Wallduct Raceway Systems"

Transcription

1 WIREMOLD Wallduct Raceway Systems Raceway Solutions for Healthcare pplications Wallduct Raceway Systems are high capacity raceways for use in walls or ceilings. They can be mounted to the wall surface or flush with the wall to meet equipment layout and room designs. The lay-in feature for enclosure of wire and cable is ideal for use in healthcare rooms, under raised floors, or as a large capacity feeder for perimeter raceway. The cover plates are easily removed for wire and cable access. Wallduct Raceway Systems can also be used with Trenchduct to carry wire and cables from cabinets to egress points anywhere on the floor or wall. Wallduct Raceway Systems are also available in aluminum for applications that require nonferrous metal raceways such as X-ray and MRI scan rooms. luminum Wallduct installed in an MRI Room. FETURES & ENEFITS n Constructed of galvannealed steel. The 14-gauge galvannealed steel has a material thickness of.0785, provides extra corrosion resistance, and is easily painted to match any room interior. n vailable in non-magnetic aluminum material. Meets requirements for MRI facilities in accordance with equipment manufacturer s specifications. n Interior couplings. Offer improved aesthetics when surface mounted. n Complete line of fittings. Lowers installation costs with fittings that can address field conditions and require minimal field modifications. n odies and covers shipped unassembled. No disassembly required before starting system installation. n 10" [254mm] and 18" [457mm] stock. Readily available warehouse stock provides for immediate shipment of customer orders. n utocd capabilities for detailing project drawings. Provides high quality detailing information with the option of electronic communication for a quicker, more accurate exchange of information. n Three standard widths. Provide cable and wire requirements for most applications. n UL Listed (UL File E4376 ase and Cover, E41751 Fittings). Product matches equipment supplier s specifications. Wallduct Raceway bodies are available in multiple widths and with flush and surface cover options. Wallduct Steel or luminum Raceway with lay-in features for enclosure of wire and cable. ED737R11 Updated May 2016 For latest specs visit

2 Wallduct Series Raceway System Layout Wallduct is commonly used in the healthcare market to feed wires and cables from electric and communication cabinets to X-ray and MRI equipment. See typical application shown. ecause some healthcare equipment requires nonmetallic material in the surrounding area, aluminum Wallduct is used in scan rooms. The equipment and control rooms generally use steel Wallduct. Equipment Room Scan Room Control Room Typical MRI Room Layout. Wallduct and Trenchduct Legend Item Catalog No. Description 1 WD10W '-0" [1524mm] Straight Length. 1a CP10-F30 30" [762mm] L Flush Cover Plate. 2 WD10W350-IL Internal Wallduct Elbow. 2a CP10-ILF Internal Wallduct Elbow Cover Flush. 3 WD10W350-HL Horizontal Wallduct Elbow. 3a CP10-HLF Horizontal Wallduct Elbow Cover Flush. 4 WD10W350-T Wallduct T-Unit. 4a CP10-TF Wallduct T-Unit Cover Flush. 5 WD10W350-X Wallduct X-Unit. 5a CP10-XF Wallduct X-Unit Cover Flush. 6 WD10W350-ECF Wallduct End Closure. 7 V12W250H-5 V Style Trenchduct 12" Wide x 2 1/2" Deep [304mm x 63mm]. 8 V12W250H-EC V Style Trenchduct End Closure. 9 V12W250H-LL V Style Trenchduct Horizontal Elbow (Left Hand). 10 V12W-VR10 V Style Trenchduct Vertical Riser. 11 WD10W350-CC/DO Wallduct Cabinet Connector. 12 WD350-CP Corner Partition. 13 WD350-P60 Straight Partition. 14 WD10W350-TUN T-Unit Straight Tunnel. 15 WD10-CPF ccess Cover Plate With Grommet. 16 WD10W350-EL Wallduct External Elbow. 16a CP10W350-ELF Wallduct External Elbow Cover Flush. 17 WD10W350-FST Wallduct Flush to Surface Transition. 18 WD10W350-LTUN T-Unit Left Hand Tunnel. 19 WD10W350-XTUN X-Unit Tunnel. 20 T250HZP-5 Trenchduct Partition. 21 V12W-VL10 Trenchduct Vertical Riser 22 WD10W350-FCCF Flanged Cabinet Connector Flush. 23 WD10W350-SWTS Sweep Surface Tee. 24 WD-10CDO Ceiling Drop Out. 25 WD350-R04 Wallduct Reducer. 26 WD18W350-SWCCS Sweep Cabinet Connector Surface. 27 WD10W350-SES Sweep Elbow Surface. Wallduct can be installed in the wall exposing only the cover plate, or it can be wall mounted exposing the entire surface. Wallduct may also be installed overhead to connect cables/ wires between rooms. Trenchduct can be used in combination with Wallduct as a feeder or for access points in the floor to feed equipment. Diagram below is for illustration only. It does not portray typical installation of products a 4 1a a 18 4a 5 1 5a 26 Cabinet (y Others) Pull ox (y Others) a 17 Wallduct Series Raceway Product Notes To attach Wallduct Series Raceway to Trenchduct, use vertical risers as shown in the current version of ED738. ll field cut openings in Wallduct Series Raceway should be grommeted as needed to protect edges from cutting cables and wires. Order Catalog # FT. Contact factory for availability of other sizes of Wallduct Series Raceway. 2

3 Catalog No./Item odies Straight Wallduct With Removable Cover Plates WD06W " [152mm] odies include two coupling angles and assembly screws. WD10W " [254mm] odies are 5' [1.3m] long and can be field cut to length. WD18W " [457mm] Surface flush covers are 30" [762mm] long. Two covers required per body. See page 10 for wire/cable fill capacity information. Surface Covers CP06-S30 6" [152mm] CP10-S30 10" [254mm] CP18-S30 18" [457mm] CP06-F30 CP10-F30 CP18-F30 Wallduct Series Raceway odies and Covers Ordering Information 8" [203mm] 12" [305mm] 20" [508mm] 30" [762mm] 30" [762mm] 3 1 2" 60" [1524mm] End View (Flush Cover Shown) NOTE: To order aluminum products, add the letter to the beginning of the catalog number. Catalog No./Item Wallduct Series Raceway ody ccessories Ordering Information WD350-P60 Straight Partition Used to separate services. Includes assembly screws for field installation. NOTE: dd the letter in front of Catalog No. for aluminum. Catalog No./Item Wire Retainer WD06-WR 6" [152mm] Used to hold wires in place WD10-WR 10" [254mm] during installation and to close WD18-WR 1 1 2" 18" [457mm] gap between cover plates if more than 1/8" [3.2mm]. Snap in place prior to installing cover plates. [38mm] 60" [1525mm] 3 1/4" [83mm] NOTE: dd the letter in front of Catalog No. for aluminum. WD350-C Coupling ngle Used for connecting two pieces of Wallduct. Includes assembly screws. Two coupling angles included with every straight body assembly " [81mm] 2" [51mm] 1 1 2" [38mm] NOTE: dd the letter in front of Catalog No. for aluminum. WD350-CP 9/16" [14.3mm] 4" [102mm] Corner Partition Used in horizontal elbow to form corner partition. ssembly screws included. Two wire retainers are included with every straight body assembly. 3 1/4" [83mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. 3

4 Catalog No./Item Wallduct Series Raceway End Closure Ordering Information Surface End Closures End Closure Used to close off end of WD06W350-ECS 6" [152mm] 6" [152mm] Wallduct run. Includes assembly screws. WD10W350-ECS 10" [254mm] 10" [254mm] WD18W350-ECS 18" [457mm] 18" [457mm] Flush End Closures WD06W350-ECF 6" [152mm] 8" [203mm] WD10W350-ECF 10" [254mm] 12" [305mm] WD18W350-ECF 18" [457mm] 20" [508mm] 1" [25mm] 3 1 2" NOTE: To order aluminum products, add the letter to the beginning of the catalog number. Catalog No./Item odies 45 Elbow Used to change direction WD06W350-HL45 6" [152mm] of Wallduct runs 45 on same plane. Includes one WD10W350-HL45 10" [254mm] pair of coupling angles, one retainer, and assembly WD18W350-HL45 18" [457mm] screws. Complete unit requires one body and one cover plate. Surface Covers CP06-HLS /8" [143mm] CP10-HLS /4" [185mm] CP18-HLS /2" [270mm] CP06-HLF-45 6" [153mm] CP10-HLF /4" [196mm] CP18-HLF-45 11" [280mm] Wallduct Series Raceway Fittings Ordering Information 3 1/2" odies Horizontal Elbow Used to change direction WD06W350-HL 6" [152mm] of Wallduct runs 90 on same plane. Includes one WD10W350-HL 10" [254mm] pair of coupling angles, one retainer, and assembly WD18W350-HL 18" [457mm] screws. Complete unit requires one body and one cover plate. Surface Covers CP06-HLS 7" [178mm] CP10-HLS 11" [279mm] CP18-HLS 19" [482mm] CP06-HLF 8" [203mm] CP10-HLF 12" [305mm] CP18-HLF 20" [508mm] 3 1 2" odies Internal Elbow Used to connect vertical and WD06W350-IL 6" [152mm] horizontal run at 90 when cover plates are on WD10W350-IL 10" [254mm] inside of run. Includes one pair of coupling WD18W350-IL 18" [457mm] angles, wire retainer, and assembly screws. Complete unit requires one elbow body and Surface Covers one cover plate. CP06-ILS 6" [152mm] CP10-ILS 10" [254mm] CP18-ILS 18" [457mm] CP06-ILF 8" [203mm] CP10-ILF 12" [305mm] CP18-ILF 20" [508mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. 4

5 Catalog No./Item Wallduct Series Raceway Fittings Ordering Information odies External Elbow Used to connect vertical and WD06W350-EL 6" [152mm] horizontal run at 90 angle when cover plates are WD10W350-EL 10" [254mm] on outside of run. Includes attached coupling angles, WD18W350-EL 18" [457mm] wire retainer, and assembly screws. Complete unit requires one elbow body and two cover plates. Surface Covers Flush and surface cover catalog numbers include CP06W350-ELS 6" [152mm] two covers. CP10W350-ELS 10" [254mm] CP18W350-ELS 18" [457mm] CP06W350-ELF 8" [203mm] CP10W350-ELF 12" [304mm] CP18W350-ELF 20" [508mm] odies Internal External Elbow Internal elbow used to WD06W350-IEL 6" [152mm] change direction 90 while also allowing for a change WD10W350-IEL 10" [254mm] in coverplate orientation. Complete unit requires one WD18W350-IEL 18" [457mm] body and one cover plate. Surface Covers CP06W350-IELS 6" [152mm] CP10W350-IELS 10" [254mm] CP18W350-IELS 18" [457mm] CP06W350-IELF 8" [203mm] CP10W350-IELF 12" [304mm] CP18W350-IELF 20" [508mm] odies T-Unit Used to connect a second run of Wallduct WD06W350-T 6" [152mm] at 90 angle to first run. Includes one pair of coupling WD10W350-T 10" [254mm] angles, one wire retainer, and assembly screws. WD18W350-T 18" [457mm] Complete unit requires one body and one cover plate. Surface Covers CP06-TS 7" [178mm] CP10-TS 11" [279mm] CP18-TS 19" [482mm] CP06-TF 8" [203mm] CP10-TF 12" [304mm] CP18-TF 20" [508mm] 3 1/2" WD10W350-TUN 11 7/8" [301mm] T-Unit Straight Tunnel Provides 3" [76mm] straight WD18W350-TUN 19 7/8" [504mm] through compartment for one service with crossover for a second service. ssembly screws included. NOTE: Not available for 6" [162mm] wide Wallduct. 3" [76mm] 3 1 4" [83mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. 5

6 Catalog No./Item Wallduct Series Raceway Fittings Ordering Information (Continued) Right Hand Tunnel Used in conjunction WD10W350-RTUN 7 7/8" [200mm] with straight partition to form a 90 angle WD18W350-RTUN 15 7/8" [403mm] 3 1 4" 3" [76mm] compartment with crossover in T-Unit. ssembly screws included. [83mm] NOTE: Not available for 6" [162mm] wide Wallduct. 3" [76mm] " Left Hand Tunnel Used in conjunction WD10W350-LTUN 7 7/8" [200mm] with straight partition to form a 90 angle WD18W350-LTUN 15 7/8" [403mm] 3 1 4" 3" [76mm] compartment with crossover in T-Unit. ssembly screws included. [83mm] NOTE: Not available for 6" [162mm] wide Wallduct. 3" [76mm] WD10W350-3TUN WD18W350-3TUN ridge Partitions Tunnel T-Unit Tunnel Provides three equal compartments for separation of services in T-Unit. ssembly screws included. Purchase partition Catalog No. WD350-P60 separately to complete installation. Partitions Partitions NOTE: Not available for 6" [162mm] wide Wallduct. odies X-Unit Used to connect two intersecting runs WD06W350-X 6" [152mm] of Wallduct at a 90 angle. Includes one pair of WD10W350-X 10" [254mm] coupling angles, one wire retainer, and assembly WD18W350-X 18" [457mm] screws. Complete unit requires one body and one cover plate. Surface Covers CP06-XS 8" [203mm] CP10-XS 12" [304mm] CP18-XS 20" [508mm] CP06-XF 8" [203mm] CP10-XF 12" [305mm] CP18-XF 20" [508mm] 3 1/2" X-Unit Crossover Used to provide a 90 WD10W350-XTUN 6 7/8" [174mm] 1" angle 3" [76mm] compartment with crossover [25mm] WD18W350-XTUN 14 7/8" [377mm] in X-Unit. ssembly screws included. NOTE: Not available for 6" [162mm] wide Wallduct. 3" [76mm] 3 1 4" [83mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. 6

7 Catalog No./Item WD10W350-3TUN WD18W350-3TUN Wallduct Series Raceway Fittings Ordering Information (Continued) ridge Partition Tunnel X-Unit Tunnel Provides three equal compartments for separation of services in X-Unit. ssembly screws included. Partition Partition Partitions Two tunnels shown. Purchase partition, Catalog No. WD350-P60 separately to complete installation. Complete X-Unit assembly requires two X-unit tunnel units. NOTE: Not available for 6" [162mm] wide Wallduct. Sweep Elbow Used to connect vertical and WD06W350-SES 6" [152mm] horizontal runs of Wallduct at a 90 angle with WD10W350-SES 10" [254mm] a 45 internal sweep radius. Includes one pair WD18W350-SES 18" [457mm] of coupling angles and assembly screws. For 14" partition use Catalog No. WD350-PSE Series. [356mm] 3 1 2" NOTE: Not available in flush cover version. 14" [356mm] 3 1 2" WD350-PSE 3.878" [98.50mm] Internal Sweep Elbow Partition Used with past #WDXWX-SES to partition elbow " [253.67mm] 3 1/2" [88.90mm] Reducer Coupling Used to reduce Wallduct WD350-RO2 2" [51mm] width by 4" [102mm] or 8" [204mm]. Two piece WD350-RO4 4" [102mm] unit allows 18" [457mm] wide Wallduct to be reduced to 10" [254mm] wide, or 10" {254mm] wide to be reduced to 6" [152mm] wide. Can also be used on other sizes as needed. ssembly screws included. Cabinet Connector/Drop Out Used to connect WD06W350-CC/DO 5 3/4" [146mm] ends of Wallduct run to panel/cabinet. lso used WD10W350-CC/DO 9 3/4" [247mm] to connect two runs of Wallduct at a 90 angle WD18W350-CC/DO 17 3/4" [450mm] when one run butts up to the bottom or top of the other. ssembly screws included. 1" 25mm] 3 1 4" [82mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. 7

8 6 Catalog No./Item Wallduct Series Raceway ccessories Ordering Information Sweep Cabinet Connector For use WD06W350-SWCCS 6" [152mm] with GE medical equipment. ttaches to 6" x WD10W350-SWCCS 10" [254mm] 3 1/2" [152mm x 89mm], 10" x 3 1/2" [254mm x WD18W350-SWCCS 18" [457mm] 89mm], or 18" x 3 1/2" [457mm x 89mm] horizontal surface Wallduct " [64mm] NOTE: Not available in aluminum " [266mm] 8" [203mm] Transition Used to form a junction between WD06W350-FST 6" [152mm] 8" [203mm] flush and surface Wallduct at a 90 angle. WD10W350-FST 10" [254mm] 12" [304mm] Includes assembly screws, clips, one wire WD18W350-FST 18" [457mm] 20" [508mm] retainer and two coupling angles. 1" [25mm] Duct ody Surface Cover Plate Duct ody Flush Surface Covers ccess Cover Plate Two-piece cover with WD06-CPS 6" [152mm] grommeted hole in center. Can be installed at any WD10-CPS 10" [254mm] location by match drilling eight holes in duct body WD18-CPS 18" [457mm] flanges and attaching speed nuts. Includes assembly screws and grommet. Use 5/16" [7.9mm] diameter drill for speed nuts. WD06-CPF 7" [178mm] WD10-CPF 11" [279mm] WD18-CPF 19" [482mm] 6" [152mm] 12" [305mm] 3"x 8" [76mm x 203mm] Hole. For 6" [152mm] cess Plate, hole size is 3" x 4" [76mm x 102mm] Sweep Tee Sweep Tee Used to connect horizontal and WD06W350-SWTS 6" [152mm] vertical runs of Wallduct at a 90 angle with WD10W350-SWTS 10" [254mm] sweep radius. Includes one pair of coupling WD18W350-SWTS 18" [457mm] angles and assembly screws. 10" [254mm] NOTE: Not available in flush cover version. 10" [254mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. 8

9 Catalog No./Item Wallduct Series Raceway ccessories Ordering Information (Continued) Flanged Connector Flanged Cabinet Connector Used to connect WD06W350-FCCS 16" [406mm] end of Wallduct run to panel cabinet. ssembly WD10W350-FCCS 22" [559mm] screws included. Use.166" [4.2mm] diameter WD18W350-FCCS 24" [610mm] (#19 drill) for assembly. WD06W350-FCCF 18" [4570mm] NOTE: Not available in aluminum. WD10W350-FCCF 24" [610mm] 6" WD18W350-FCCF 26" [660mm] [152mm] Ceiling Drop Out Ceiling Drop Out Used to drop cables and WD-10CDO 4" [102mm] to 5 3/4" [146mm] wires from Wallduct in ceiling to imaging WD-10CDOD 5 1/2" [140mm] to 7 1/4" [184mm] equipment. vailable in 10" [254mm] width only. Units have adjustable depth. 10" [254mm] NOTE: To order aluminum products, add the letter to the beginning of the catalog number. Part No: Wallduct Series Raceway Replacement Hardware Ordering Information Wallduct Replacement Hardware Hardware bag with twelve (12) 10/32 x 7/8" pan head screws Wallduct Replacement Hardware Hardware bag with eight (8) 10/32 x 1/4" pan head screws. Part No: FT Wallduct Grommet pplied to edges of Wallduct and fittings where cables egress to protect against damage to cable insulation. Packed 100' of grommet per unit Wallduct Replacement Hardware Hardware bag with twelve (12) cover clips. Wallduct is ideal for use in medical scan rooms. 9

10 Wallduct Series Raceway Wire Fill Capacity Use these steps to determine wire fill capacity in Wallduct. Step 1: Determine the internal raceway area by multiplying the overall width by the overall depth (subtract material thickness). Example: ssume a raceway 10" wide by 4" deep. Subtract the material thickness from each dimension (see below). This results in internal raceway dimensions of 9.844" (10" ") wide by 3.922" (4" "). The internal area for this raceway size would be 38.6 sq. in. (9.844" x 3.922"). Deduct for Deduct for Maximum Raceway Material Material Width (In.) Thickness Thickness Left & Right (ottom) 6" 18" Steel 0.156" 0.078" 20" 30" Steel 0.216" 0.108" 6" 18" luminum 0.200" 0.100" 20" 30" luminum 0.250" 0.125" Step 2: Determine the number of conductors allowed inside the raceway for a given type and size (types THHN and THWN are shown in Table 1) of the conductor by multiplying the internal area (calculated in Step 1) by the number of conductors allowed per square inch (see table 1). Example: Calculate how many No. 6 WG (THHN) conductors you are allowed to place in the 10" x 4" raceway in Step 1 at 40% wire fill capacity. Multiply the internal area of the raceway by the maximum number of wires allowed per square inch, from table 1. This results in 304 allowable cables (38.6 sq. in. x 7.89). 20% fill should be used for systems utilizing fittings that have sharp 90 turns. The derating factors of NEC article ()(2)(a) shall apply to conductors installed if the amount of current-carrying conductors exceeds 30 in number, or the sum of the crosssectional area of all conductors exceeds 20% of the interior cross-sectional area of the raceway. When tunnels are utilized, the internal cross-sectional area must be further reduced by 50%. When partitions are utilized, the internal cross-sectional area must be calculated for each individual compartment. Table 1 Steel Wallduct Wire Fill Capacities for Power WIRE SIZE DIMETER RE (In 2 ) 40% FILL 20% FILL WG In. [mm] Sq. In. [Sq. mm] (Per Sq. In.) (Per Sq. In.) [2.8] [6.3] [3.3] [8.6] [4.2] [13.6] [5.5] [23.6] [6.5] [32.7] [8.2] [53.2] [8.9] [62.8] [9.8] [74.7] Table 2 Steel Wallduct Wire Fill Capacities for Data/Communications DIMETER RE (In 2 ) 40% FILL 20% FILL CLE/WIRE SIZE In. [mm] Sq. In. [Sq. mm] (Per Sq. In.) (Per Sq. In.) UNSHIELDED 4-Pair, Cat 5e [5.6] [24.6] 10 5 TWISTED PIR 4-Pair, Cat [6.4] [31.7] 14 7 TELEPHONE 2-Pair, 24 WG [3.5] [9.9] Pair, 24 WG [4.8] [18.2] Pair, 24 WG [10.4] [85.2] 3 1 COXIL RG58/U [4.9] [19.2] 13 6 RG59/U [6.1] [29.6] 9 4 RG6/U [6.8] [36.9] 7 3 SHIELDED TYPE [9.9] [77.0] 3 1 TWISTED PIR TYPE [11.8] [109.5] 2 1 TYPE [6.2] [30.4] 0 4 FIER OPTIC 2-STRND [4.6] [16.4] STRND [4.8] [15.3] STRND [5.3] [22.3] 11 5 FIER ZIP CORD [2.8] [6.1] NOTE: Wire diameters can vary depending on manufacturer. Verify diameter and adjust fill capacities as required. Values are per one square inch of Wallduct area. 10

11 Wallduct Series Raceway Take-Off Sheet Project Name: Location: 1. Enter the correct size and width of each part number (WD"6"W"350"-60). 2. Provide correct covers, dividers, tunnels, hardware, fittings as required. 3. Provide correct part number of covers per bodies of WallDuct (two covers per WallDuct body). WD W -60 ody Run # WD W -60 ody Run # CP W -S30 Surface Cover CP W -S30 Surface Cover CP W -F30 Flush Cover CP W -F30 Flush Cover WD -P60 Straight Partition WD -P60 Straight Partition WD -C Coupling ngle WD -C Coupling ngle WD -WR Wire Retainer WD -WR Wire Retainer WD -CP Corner Partition WD -CP Corner Partition WD W -ECS Surface End Closure WD W -ECS Surface End Closure WD W -ECF Flush End Closure WD W -ECF Flush End Closure WD W -HL45 45 Elbow ody WD W -HL45 45 Elbow ody CP -HLS Elbow Surface Cover CP -HLS Elbow Surface Cover CP -HLF Elbow Flush Cover CP -HLF Elbow Flush Cover WD W -HL Horizontal Elbow ody WD W -HL Horizontal Elbow ody CP -HLS Horizontal Surface Cover CP -HLS Horizontal Surface Cover CP -HLF Horizontal Flush Cover CP -HLF Horizontal Flush Cover WD W -IL Internal Elbow ody WD W -IL Internal Elbow ody CP -ILS Internal Elbow Surface Cover CP -ILS Internal Elbow Surface Cover CP -ILF Internal Elbow Flush Cover CP -ILF Internal Elbow Flush Cover WD W -EL External Elbow ody WD W -EL External Elbow ody CP W -ELS External Elbow Surface Cover CP W -ELS External Elbow Surface Cover CP W -ELF External Elbow Flush Cover CP W -ELF External Elbow Flush Cover WD W -T T-Unit ody WD W -T T-Unit ody CP -TS T-Unit Surface Cover CP -TS T-Unit Surface Cover CP -TF T-Unit Flush Cover CP -TF T-Unit Flush Cover WD W -TUN Straight Tunnel WD W -TUN Straight Tunnel WD W -RTUN Right Hand Tunnel WD W -RTUN Right Hand Tunnel WD W -LTUN Left Hand Tunnel WD W -LTUN Left Hand Tunnel WD W -3TUN T-Unit Tunnel WD W -3TUN T-Unit Tunnel WD W -X X-Unit ody WD W -X X-Unit ody CP -XS X-Unit Surface Cover CP -XS X-Unit Surface Cover CP -XF X-Unit Flush Cover CP -XF X-Unit Flush Cover WD W -XTUN X-Unit Crossover WD W -XTUN X-Unit Crossover WD W -3TUN X-Unit Tunnel WD W -3TUN X-Unit Tunnel WD W -SES Sweep Elbow WD W -SES Sweep Elbow WD -RO2 Reducer Coupling WD -RO2 Reducer Coupling WD -RO4 Reducer Coupling WD -RO4 Reducer Coupling WD W -CC/DO Cabinet Connector Drop Out WD W -CC/DO Cabinet Connector Drop Out WD W -SWCCS Sweep Cabinet Connector WD W -FST Transition WD -CPS Surface ccess Cover Plate WD -CPF Flush ccess Cover Plate WD W -SWTS Sweep Tee WD W -FCCS Flanged Cabinet Connector WD W -FCCF Flanged Cabinet Connector WD-10CDO Ceiling Drop Out WD-10CDOD Ceiling Drop Out WD W -SWCCS Sweep Cabinet Connector WD W -FST Transition WD -CPS Surface ccess Cover Plate WD -CPF Flush ccess Cover Plate WD W -SWTS Sweep Tee WD W -FCCS Flanged Cabinet Connector WD W -FCCF Flanged Cabinet Connector WD-10CDO Ceiling Drop Out WD-10CDOD Ceiling Drop Out 11

12 NOTES NOTE: ll brand and product names referenced in this document are registered trademarks or trademarks of their respective holders. NOTE: The paper used to print this document is an environmentally responsible paper with 10% post consumer waste, with FSC and SFI Chain of Custody certifications, Lacey ct complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e certified renewable energy. ED737R11 Updated May 2016 For latest specs visit Copyright 2016 Legrand ll Rights Reserved Electrical Wiring Systems 60 Woodlawn Street West Hartford, CT Phone: Y.LEGRND ( ) pplewood Crescent Vaughan, Ontario L4K 44 Phone:

n Flush activations for single-, double-, and triple-duct runs

n Flush activations for single-, double-, and triple-duct runs Highly flexible duct system to meet varying project demands Walkerduct Underfloor Duct System includes two sizes of underfloor ducts - No.2 and No. 4 - for maximum flexibility. This allows you to match

More information

WIREMOLD Pancake Overfloor Raceway

WIREMOLD Pancake Overfloor Raceway WIREMOLD Pancake Overfloor Raceway Steel Pancake Overfloor Raceway Pancake Overfloor Steel Raceway is ideal for open space wiring of workstations and desk areas in high traffic sites. Both the 1500 and

More information

WIREMOLD Service Fittings

WIREMOLD Service Fittings WIREMOLD Service Fittings ctivations for Every pplication! Walkerduct Pro Series Service Fittings offer a complete range of service fittings to meet all power, data and communication requirements. The

More information

WIREMOLD. Aluminum Single Channel Raceway. Aluminum Raceway. Available Factory Prewired.

WIREMOLD. Aluminum Single Channel Raceway. Aluminum Raceway. Available Factory Prewired. Aluminum Single Channel Raceway Available Factory Prewired. WIREMOLD Aluminum Raceway Isoduct ALA3800 Series Aluminum Raceway System meets the demands of commercial spaces, providing a handsome and effective

More information

F E A T U R E S & B E N E F I T S

F E A T U R E S & B E N E F I T S Multi-Compartment Surface Metal Raceway AnySize Raceway allows you to precisely size surface raceway to meet specific wiring capacity needs. Simply choose the material and finish you want, then specify

More information

Raceway Solutions TM. Wall Duct. Catalog Number System OWA / D 12 S AL. Flush or Surface Mounted Wiring System for X-Ray Rooms

Raceway Solutions TM. Wall Duct. Catalog Number System OWA / D 12 S AL. Flush or Surface Mounted Wiring System for X-Ray Rooms Flush or Surface Mounted Wiring System for X-Ray Rooms is a steel raceway, approved by U.L. for the enclosure of wiring to X-ray machines in medical applications. The system provides complete lay-in wiring

More information

ED923R7 Updated April 2011 For latest specs visit

ED923R7 Updated April 2011 For latest specs visit Modulink 880MP Series Floor oxes 880MP Series Nonmetallic Floor oxes FIER OPTIC CT5 Wiremold Modulink 880 Series Nonmetallic Floor oxes provide power and communication services directly to the workstation

More information

Information technology professionals in the Department of

Information technology professionals in the Department of Data-Fense Secure Raceway System Enhanced Protection of Critical Networks For Government, Financial Institutions, and R&D Facilities Information technology professionals in the Department of Defense, government

More information

WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES.

WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES. 1 WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES. 1 BOX. MULTIPLE FLOOR TYPES AND SURFACES. Wood Floor Concrete Floor Raised Floor 1 BOX. 6 FINISHES. Carpet, tile, wood, terrazzo and polished concrete

More information

WIREMOLD Ratchet-Pro Series Floor Boxes

WIREMOLD Ratchet-Pro Series Floor Boxes WIREMOLD Ratchet-Pro Series Floor Boxes Wiremold Single & Dual-Service Round Floor Boxes Wiremold Ratchet-Pro Series Floor Boxes provide single- and dual-service capability in a variety of easyto-install

More information

Now you can precisely size surface raceway to

Now you can precisely size surface raceway to AnySize Raceway AnySize Multi-Compartment Surface Metal Raceway Now you can precisely size surface raceway to meet your wiring capacity needs. Simply choose the material and finish you would like, then

More information

The newly redesigned FloorPort

The newly redesigned FloorPort FloorPort Service Fittings & Accessories New Redesigned FloorPort Service Fittings Supply the Versatile Workstation Protection from water, dirt, and debris. The newly redesigned FloorPort Service Fittings

More information

Introducing the next generation in

Introducing the next generation in Innovative Raceway Profile Provides Increased Wiring Capacity Available Factory Prewired 4000 Designer Series Steel Raceway Introducing the next generation in innovative surface raceway systems. The new

More information

Bring power safely and conveniently to wherever

Bring power safely and conveniently to wherever Plug-In Outlet Center Units Plug-In Outlet Center Units Bring power safely and conveniently to wherever you need it with a full line of Plug-In Outlet Center Units from Wiremold/Legrand. These units are

More information

Modulink. Wiremold 880MP Series Nonmetallic Floor Boxes. 880 Series Floor Boxes

Modulink. Wiremold 880MP Series Nonmetallic Floor Boxes. 880 Series Floor Boxes Modulink 880 Series Floor Boxes Wiremold 880MP Series Nonmetallic Floor Boxes Wiremold Modulink 880 Series Nonmetallic Floor Boxes provide power and communication services directly to the workstation or

More information

Poke-Thru Devices from Wiremold/ Legrand provide

Poke-Thru Devices from Wiremold/ Legrand provide Chicago Approved Poke-Thru Devices Bring High Capacity Power and Communication Services to Above Grade Open Space Areas Protection from water, dirt, and debris. Poke-Thru Devices from Wiremold/ Legrand

More information

The selection of lengths and fittings in a variety of

The selection of lengths and fittings in a variety of Plugmold Systems Steel Plugmold Raceway & Multioutlet Assemblies The selection of lengths and fittings in a variety of finishes provides a versatile solution for many applications. Plugmold sections offer

More information

FloorPort Series. Redesigned Service Fittings Supply the Versatile Workstation. Service Fittings

FloorPort Series. Redesigned Service Fittings Supply the Versatile Workstation. Service Fittings FloorPort Series Service Fittings Redesigned Service Fittings Supply the Versatile Workstation TOPGUARD A/V INTEGRATION The newly redesigned FloorPort Service Fittings for Resource RFB Series Floor Boxes,

More information

MOUNTING SYSTEMS SPECIFICATIONS

MOUNTING SYSTEMS SPECIFICATIONS MOUNTING SYSTEMS SPECIFICATIONS GENERAL Mounting Systems shall allow Track Systems to be fastened to or from various surfaces in a wide range of safe and approved methods. Mounting Systems shall have a

More information

Convention Center Series Products

Convention Center Series Products Convention Center Series Products Large Capacity, Multi-Utility Products Protection from water, dirt, and debris. Wiremold Convention Center Series Products are industry leading solutions for providing

More information

Metal Raceway Systems. tomorrow. Wiremold Metal Raceway. Innovative from Day One.

Metal Raceway Systems. tomorrow. Wiremold Metal Raceway. Innovative from Day One. Metal Raceway Systems tomorrow 1916 Wiremold Metal Raceway. Innovative from Day One. Wiremold metal raceway has been defining the category for close to a century. Offering the broadest, most innovative

More information

Evolution Series Poke-Thru Devices

Evolution Series Poke-Thru Devices Wiremold Evolution Series Poke-Thru Devices are the latest addition to the largest offering of poke-thru solutions available in the industry. Combining new models that provide larger capacity options,

More information

Recessed Floor Boxes for Concrete & Wood Floors

Recessed Floor Boxes for Concrete & Wood Floors Resource RF Series Floor oxes with Rectangular ctivations Recessed Floor oxes for oncrete & Wood Floors Resource RF Series of Floor oxes are versatile recessed activation solutions that provide power,

More information

Cable & Wire Management

Cable & Wire Management Cable & ire Management ay-in ireway Data Sheet Cable & ire Management pplication ouses runs of control and power cable Protects against circulating dust, falling dirt and dripping noncorrosive liquids

More information

COMPACT BUSWAY 40 & 60 AMP HOUSING

COMPACT BUSWAY 40 & 60 AMP HOUSING 40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum

More information

Resource RFB Series Floor Boxes

Resource RFB Series Floor Boxes Resource RF Series Floor oxes Recessed Floor oxes for oncrete & Wood Floors Wiremold Resource RF Series of Floor oxes are versatile recessed activation solutions that provide power, communication and/or

More information

Resource RFB Series Floor Boxes

Resource RFB Series Floor Boxes Resource RF Series Floor oxes Recessed Floor oxes for Wood & oncrete Floors Wiremold Resource RF Series of Floor oxes are versatile activation solutions that provide power, communication and/or audio video

More information

Cable & Wire Management

Cable & Wire Management able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...

More information

Series 1 Steel - Accessories

Series 1 Steel - Accessories - ccessories Standard (L-Shaped) Splice Plates One pair including hardware provided with each section. Prepackaged in pairs in a plastic bag, with hardware. 4-hole pattern L-shaped splice plates. L-shaped

More information

T&B Cable Tray. In this section...

T&B Cable Tray. In this section... In this section... T& Cable Tray T& Cable Tray Overview... -260-261 luminum Tray... -262-309 Steel Tray... -310-333 One-Piece Tray... -334-357 Channel Tray... -358-373 Common ccessories... -374-376 Grounding

More information

Cable & Wire Management

Cable & Wire Management Type 1 Screw over... 8-14 Type 1 Quick-onnect inge over... 15-20 Type 3R nviroshield... 21-24 Type 12... 25-31 eed-through Wireway Type 12... 32-35 eed-through Wireway Type 4X... 36-39 Wiring Trough Type

More information

RC3, RC7 & RC4 Receptacle Replacement

RC3, RC7 & RC4 Receptacle Replacement RC3, RC7 & RC4 Receptacle Replacement INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 003 786R1 Updated October 2003 Walker electrical systems conform to and should be properly grounded in compliance

More information

More innovative solutions for an ever-evolving world. Electric Vehicle Chargers

More innovative solutions for an ever-evolving world. Electric Vehicle Chargers More innovative solutions for an ever-evolving world. Electric Vehicle Chargers Reliable EV charging solutions from an electrical innovator you can trust. Electric vehicles (EVs) are hitting the road in

More information

880W Series. Rectangular Floor Boxes for Wood Floors. Floor Boxes for Wood Floors

880W Series. Rectangular Floor Boxes for Wood Floors. Floor Boxes for Wood Floors Rectangular Floor Boxes for Wood Floors 880W Series Floor Boxes for Wood Floors Wiremold 880W Series Wood Floor Boxes provides an excellent solution for unique wood floor applications when power and communication

More information

EFSB4 4-Gang Wall Box. Features. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

EFSB4 4-Gang Wall Box. Features. Description. Manufacturer Information. Taxonomies, Classifications, and Categories 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4-Gang Wall Box Wiremold/Legrand Catalog Number Manufacturer Description Weight per unit Product Category Features Item

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories The following is a list of accessories and fittings that can be provided with S8 tray. For more information on these items, contact our Engineering Department. Fittings Horizontal Bends 30 Bends with 24,

More information

Ideal for surface mounting

Ideal for surface mounting One-Piece Surface Steel Raceway V500 /V700 /700H Steel Raceway Ideal for surface mounting small amounts of electrical wiring or communication cables. These rugged raceways offer a low profile appearance

More information

RECESSED TRACK (120V) SPECIFICATIONS

RECESSED TRACK (120V) SPECIFICATIONS RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched,

More information

Product Selection Guide

Product Selection Guide Selection Guide Selection Guide TABLE OF CONTENTS T1 Series: 40, 50 & 60 Amps...1.1-1.29 T2 Series: 60, 100 Amps...2.1-2.44 T3 Series: 100 & 225 Amps...3.1-3.37 T5 Series: 250, 400 & 800 Amps...4.1-4.51

More information

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast 1.Question: An add on unit for a hydromassage bathtub consists of a small 1-gallon water heater

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

FIRE CLASSIFIED FLOOR BOXES Omnibox Series Floor Boxes

FIRE CLASSIFIED FLOOR BOXES Omnibox Series Floor Boxes FIRE CLASSIFIED Omnibox Series Floor Boxes OmniBox Series Floor Boxes Solid Brass Cover Plate Flanges Ordering Information 817B One-Gang Brass Combination adapters and Wiremold CM Series 4 3/4" 880CS1-1

More information

ELECTRICAL ACCESSORIES FOR 1 5 8" (41 MM) WIDTH SERIES CHANNEL

ELECTRICAL ACCESSORIES FOR 1 5 8 (41 MM) WIDTH SERIES CHANNEL ELECTRICL CCESSORIES FOR 5 8" (4 MM) WIDTH SERIES CHNNEL Page Electrical Fittings Receptacles Fixture Hangers ccessories and Connectors Junction Boxes In-Channel Joiners Swivel Hangers Cable Entrance Tubing

More information

Operator Enclosures. Console Type 12 - AW-14 Data Sheet

Operator Enclosures. Console Type 12 - AW-14 Data Sheet Console Data Sheet Construction Console body, panel cover and door, top assembly and writing desk are fabricated from (14) gauge steel ll continuous welded seams are finished smooth Panel cover is secured

More information

Square-Duct Wireways. Catalog 5100CT0101R06/ Class CONTENTS Description... Page. Wireway Offerings... 3

Square-Duct Wireways. Catalog 5100CT0101R06/ Class CONTENTS Description... Page. Wireway Offerings... 3 Catalog 5100CT0101R06/11 2011 Class 5100 CONTENTS Description............................................. Page Wireway Offerings............................................ 3 General Purpose NEMA Type

More information

GEMINI HOUSING SPECIFICATIONS

GEMINI HOUSING SPECIFICATIONS GEMINI HOUSING SPECIFICATIONS GENERAL Gemini Housing shall support Track of six foot intervals. In addition, the extra compartment shall be able to be used for a multitude of elec trical or mechanical

More information

SURFACE TRACK (120/250V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed

More information

Series 1 Steel - Straight Sections

Series 1 Steel - Straight Sections Series 1 Steel - Straight Sections Series 1 Steel H-1 B-Line series Cable Tray Systems Series 1 Steel - ccessories & Fittings Series 1 Steel How The Service dvisor Works We know that your time is important!

More information

WIREMOLD Fire Classified Floor Boxes

WIREMOLD Fire Classified Floor Boxes Legrand takes Wiremold floor boxes to the next level with the introduction of seven recessed and flush style f l o o r b o x m o d e l s t h a t m e e t o r e x c e e d U L F i re Classification requirements.

More information

INTEGRID TRACK (120V) SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to

More information

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com G20GB12 Gry 3W1CKT Plugmold Wiremold/Legrand Catalog Number Manufacturer Description Weight

More information

Series 1 Steel - Straight Sections

Series 1 Steel - Straight Sections - Straight Sections H-1 -Line series able Systems - ccessories & Fittings How The Service dvisor Works We know that your time is important! That s why the color-coding system in this catalog is designed

More information

A revolutionary new multi-channel raceway, InfoStream features a unique, rounded profile which offers a sleek appearance and helps absorb shock.

A revolutionary new multi-channel raceway, InfoStream features a unique, rounded profile which offers a sleek appearance and helps absorb shock. A revolutionary new multi-channel raceway, InfoStream features a unique, rounded profile which offers a sleek appearance and helps absorb shock. Many features, including InfoStream s light weight, make

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories Wedge Lock Splice Plates Standard 4-hole pattern. Furnished in pairs, with hardware. One pair including hardware provided with each section. Boxed in pairs with hardware. For field installation drill 13

More information

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit Ortronics Mighty Mo GX Cabinets Designed to Perform, Configured to Fit Mighty Mo GX Configured By You, Made By Legrand Ortronics 2 Ortronics (adj.) ef fi cient Performing or functioning in the best possible

More information

Series 2, 3, 4, & 5 Steel - Accessories

Series 2, 3, 4, & 5 Steel - Accessories - ccessories Splice Plates Standard 8-hole pattern for all steel splice plates. One pair including hardware provided with straight section. Boxed in pairs Expansion Splice Plates Expansion plates allow

More information

Series 1 Steel - Straight Sections

Series 1 Steel - Straight Sections LST-1 able Systems - Straight Sections How The Service dvisor Works -Line knows that your time is important! That s why the color-coding system in this catalog is designed to help you select products that

More information

G20GB606 PLGMD 6'SGL CRT 6" 2000 Gray. Manufacturer Information. Packaging Carton 1 Package 2 Weight Per each Description

G20GB606 PLGMD 6'SGL CRT 6 2000 Gray. Manufacturer Information. Packaging Carton 1 Package 2 Weight Per each Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 G20GB606 PLGMD 6'SGL CRT 6" 2000 Gray Wiremold/Legrand Catalog Number G20GB606 Manufacturer Wiremold/Legrand Description

More information

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read

More information

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and

More information

EZTray. Cable Management Made Easy

EZTray. Cable Management Made Easy EZTray Cable Management Made Easy PRESENTATION Introduction:.................................. 3 EZ Tray: The Tray That Saves You Time!.............. 4-5 EZ Tray: The Innovative Cable Management Solution....

More information

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax:

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax: 168 Georgetown Road Canonsburg, PA 15317 USA Phone: 724-597-7800 Toll Free: 800-245-6378 Fax: 724-916-2221 www.uecorp.com info@uecorp.com A DIVISION OF Introduction Plug-In Accessories Application Briefs

More information

Electrical Metallic Tubing (EMT) and True Color EMT

Electrical Metallic Tubing (EMT) and True Color EMT Electrical Metallic Tubing (EMT) and True Color EMT E-Z Pull EMT Hot galvanized steel using patented inline Flo-Coat process for long lasting exterior protection E-Z Pull interior coating provides a smooth

More information

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod ulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS30; -DSX30 - Series D; 494V-DS; -DSX - Series D) (Cat 494V-DS00; -DSX00 - Series D; 494V-DS00; -DSX00 - Series D) TTENTION:

More information

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1 HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

Product Specifications Color Changing LED Can Lighting

Product Specifications Color Changing LED Can Lighting NOVA Energy & Automation Product Specifications Color Changing LED Can Lighting Model NEA-RGBCan 03 January 2012 Product Description 1. RGB Color Changing Lighting Color Changing Lighting is commonly used

More information

Electrical Accessories

Electrical Accessories complete system of top quality, time saving products, designed for surface metal raceways, lighting and cable supports. Innovative designs offer many installation advantages. -Line s surface raceways are

More information

Walkerflex Modular Wiring System

Walkerflex Modular Wiring System New Walkerflex Modular Wiring System Offers Labor Savings Compared To Hard-Wired Systems Wiremold Walkerflex Modular Wiring System is a factory assembled connector and cable set system, designed to interface

More information

PART NUMBER BREAKDOWN

PART NUMBER BREAKDOWN SERIES 34 O-Ring Sealed Shorting Cap Series 34 Shorting Caps are for use at the rear of shorting plugs, special test connectors, fiber optic loopbacks and other applications. variety of lanyard options

More information

NWC, NCS, NCW, NCBS, NPA, NDU, RECDU, CAP3456, CAP810, LDU, LWC, LPA, LCBS, LCW, WWC, WCS, WCW, WPA, WCBS, WDU NOTE:

NWC, NCS, NCW, NCBS, NPA, NDU, RECDU, CAP3456, CAP810, LDU, LWC, LPA, LCBS, LCW, WWC, WCS, WCW, WPA, WCBS, WDU NOTE: Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. Walkerflex Modular

More information

The Industrial Choice. Model PB. Belt Driven. Model PB Direct Drive PRESSURE BLOWER. Model PB

The Industrial Choice. Model PB. Belt Driven. Model PB Direct Drive PRESSURE BLOWER. Model PB The Industrial hoice. Model P elt Driven Model P Direct Drive PRESSURE LOWER Model P ULLETIN 904 March 999 Model P Pressure lowers Pressure blowers provide medium pressure air for cooling, ventilating

More information

Installation Instructions: ACCENT SYSTEM

Installation Instructions: ACCENT SYSTEM Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire

More information

Panels and Doors. Page How to Order

Panels and Doors. Page How to Order Panels and Doors Page How to Order 204 Introduction to Section 6 djustable & luminum Hinges Door Handles, Catches, Latches, & Locks Sliding Door Glide Roller Wheels Roller Wheel Bracket Door Slide Tracks

More information

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect installation

More information

Installation Instructions

Installation Instructions Contents Page General Information and Installer Tips.......... 2 Panels & Posts............................. 3 Enclosure Description..................... 4 Hinge Door Hardware................... 4-5 Step-by-Step

More information

Lumination TM LED Luminaire LUR Series

Lumination TM LED Luminaire LUR Series Installation Guide Lumination TM LED Luminaire LUR Series BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Turn power off before inspection,

More information

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and

More information

OPEN STEEL SHELVING S & S X- R AY PR O D UCTS

OPEN STEEL SHELVING S & S X- R AY PR O D UCTS OPEN STEEL SHELVING 8 0 0 / 3 4 7 - X R AY S & S X- R AY PR O D UCTS CHOICE OF TWE LVE SIZES RIGID ALL STEEL CONSTRUCTION CONVENIENT FOR ACTIVE AND I NACTIVE FILES LOW COST File x-ray envelopes the most

More information

4412HS Wway 4X4X12 N1 HC Lay-In. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

4412HS Wway 4X4X12 N1 HC Lay-In. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 4412S Wway 4X4X12 N1 Lay-In ooper -Line/able Tray atalog Number Manufacturer Description Weight per unit Product ategory

More information

High Speed Fuses. Section Contents Page

High Speed Fuses. Section Contents Page Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Centrifugal Inline Fans

Centrifugal Inline Fans Centrifugal Inline Fans Models SQ-M and SQ-M Direct and elt Drive UILDING VLUE IN IR. February January 2018 2017 Models SQ-M & SQ-M Centrifugal Square Inline Duct Fans Designed for indoor and outdoor clean

More information

PVC-LINK. High Impact, Complete Flexibility. Product Catalogue Cable Management System Distribution Enclosure & Weatherproof Boxes

PVC-LINK. High Impact, Complete Flexibility. Product Catalogue Cable Management System Distribution Enclosure & Weatherproof Boxes PVC-LINK High Impact, Complete Flexibility Product Catalogue Cable Management System Distribution Enclosure & Weatherproof oxes PVC-LINK High Impact,Complete Flexibility COMPLINCE TO STNDRD PVC-LINK is

More information

freestanding desks SELL SHEET Pg 01/

freestanding desks SELL SHEET Pg 01/ SELL SHEET FETURES Easy to specify: ll work surfaces rest on panel and corner legs, rather than pedestals. Storage options are innumerable and simply slide beneath the desk shells, return shells, and corner

More information

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings In This Section and Steel City Overview...F-2 F-3 Thinwall Conduit (EMT)...F-4 F-9 Rigid/Intermediate Grade Conduit...F-0 7 Flexible Cord and Power Cable Connectors...F-8 Liquidtight Flexible Metal Conduit

More information

1Unpack fixture. Suspensions/canopies are ordered and

1Unpack fixture. Suspensions/canopies are ordered and DO NOT REMOVE THE LED ASSEMBLY. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 questions. Fixture is intended installation in accordance with bee servicing. Retain these instructions 2Determine

More information

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM Installation Instructions: ACCENT HIGH OUTPUT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS

More information

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only CAUTION: Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect

More information

FiberGuide Fibre Management Systems

FiberGuide Fibre Management Systems FiberGuide Fibre Management Systems Table of Contents Introduction...................................................................... 1 Features and Benefits..............................................................

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

2-row and All-row systems included.

2-row and All-row systems included. Ag Leader Technology Cotton Picker Installation Installation Instructions for John Deere cotton picker models: 2-row and All-row systems included. IMPORTANT: Ensure the model numbers shown above correspond

More information

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and

More information

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10) A/C Disconnects 60 amps Non-fused. 240v A.C. Single Phase. UL Listed Three piece construction that opens up mounting and wiring areas, reduces installation time. Terminals approved for 60*C and 75*C wire.

More information

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems Juno Trac-Master Trac Lighting Systems Comprehensive line and low voltage track systems Juno Trac-Master System Safe and simple installation is what you can expect from Juno one-circuit and two-circuit

More information

TS , -850 Series TS , -850 Series TS-57031, TS

TS , -850 Series TS , -850 Series TS-57031, TS TS-5711-770, -850 Series TS-57011-770, -850 Series TS-57031, TS-57031-850 Electronic Room Temperature Sensors General Instructions Application These sensors provide electronic sensing of room temperature

More information

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping.

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping. PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEW 3 5/8" 92mm 2 1/4 57mm ORDERING CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PRODUCT SPECIFICATIONS 1 PRODUCT ID 2 OPTICS 3 LENGTH (FT)

More information

F E A T U R E S & B E N E F I T S. ED755R13 Updated September 2011 For latest specs visit

F E A T U R E S & B E N E F I T S. ED755R13 Updated September 2011 For latest specs visit New Walkerflex Modular Wiring System Offers Labor Savings Compared To Hard-Wired Systems Wiremold Walkerflex Modular Wiring System is a factory assembled connector and cable set system, designed to interface

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information