NWC, NCS, NCW, NCBS, NPA, NDU, RECDU, CAP3456, CAP810, LDU, LWC, LPA, LCBS, LCW, WWC, WCS, WCW, WPA, WCBS, WDU NOTE:

Size: px
Start display at page:

Download "NWC, NCS, NCW, NCBS, NPA, NDU, RECDU, CAP3456, CAP810, LDU, LWC, LPA, LCBS, LCW, WWC, WCS, WCW, WPA, WCBS, WDU NOTE:"

Transcription

1 Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. Walkerflex Modular Wiring System I N S T A L L A T I O N I N S T R U C T I O N S Installation Instruction No.: R Updated August 011 All electrical products may present a possible shock or fire hazard if improperly installed or used. Wiremold electrical products may bear the mark as UL Listed and/or Classified and should be installed in conformance with current local and/or the National Electrical Code. IMPORTANT: Please read all instructions before beginning. Products Covered: FCA, NWC, NCS, NCW, NCBS, NPA, NDU, RECDU, CAP, CAP10, LDU, LWC, LPA, LCBS, LCW, WWC, WCS, WCW, WPA, WCBS, WDU NOTE: Label on product indicates which products are suitable for use in air handling spaces in accordance with Sec. 00-(C) of the National Electric Code. 1. Each Walkerflex component contains a unique connector key and color indicating rating, conductor location and orientation. Only like color keys can be mated. See Key Configuration and Color Chart for available options.. Each Walkerflex key is comprised of one or more configurations that determine the number of line and neutral conductors. Only identical configurations can be mated. See Key Configuration and Color Chart for available options.. Disconnect power from source prior to wiring any Walkerflex component into building s electrical power system.. Installer to determine maximum cable length based on wire gauge and circuit load.. Installer to ensure adequate overload protection based on system key, rating and circuit load.. Refer to appropriate Wiring Diagram and System Key Configuration Conductor Location Chart for field connections of Cat. Nos. NWC/LWC (Wire Connector) and NCW/LCW (Cable Whips). Refer to wiring diagram supplied with NDU/LDU (Distribution Unit) for field termination.. Securing and Supporting of Cables and Components: Refer to NEC Article 0, Manufacturing Wiring Systems and any local codes.. Cap all unused connector openings with Cat. No. CAP (for through wire system) or Cat. No. CAP10 ( and 10 wire system). 9. V Walkerflex components are only available in - wire configurations. 10.The Walkerflex system is compatible with the Convia enabled Walkerflex system of the same configuration and key. NDU/LDU (Distribution Unit) NOTE: Cap Unused Connectors On All Power Out Modules. Power Out Power In CAP/CAP10 (End Cap) Power In Power Out Secure Box in Place Feed Power Out Connected to Protected Circuit(s) Cat. No. NCS/LCS/WCS

2 TYPICAL WALKERFLEX SYSTEM INSTALLATION Cat. No. NWC/LWC/WWC (Wire Connector) Cat. No. NPA/LPA/WPA (Power Adapter) CAUTION: Do not make or break connections while circuits are energized. Cat. No. NCS/LCS/WCS Cat. No. NCBS/LCBS/WCBS (Splitter) Mate only identical Keys and Configurations. Cat. No. NCW/LCW/WCW (Cable Whip) WALKERFLEX SYSTEM ACCESSORIES (10V Only) TYPICAL PREWIRED ACCESS FLOOR BOX INSTALLATIONS WALKERFLEX FURNITURE FEED DISTRIBUTION UNIT Access Floor Box Cat. No. NCS Cat. No. NPA (Power Adapter) Cat. No. NCS Cat. No. NDUXXXFF (Furniture Feed) Cat. No. NCS Cat. No. NCW (Cable Whip) WALKERFLEX RECEPTACLE DISTRIBUTION UNIT NOTE: All Walkerflex accessories are available in both the - and -10 pin systems with the exception of NPA/LPA/WPA which is only available for the - pin system. Cat. No. RECDU (Receptacle Unit) NOTE: Not suitable for use in Air Handling Spaces. Cat. No. NCS

3 WALKERFLEX SYSTEM ACCESSORIES RCATCALPA CSTCPPA AVATCAL111PA FFATCALCW CRFBAC111PA AFKC111PA AC10YC111PA SAFKC111PA EFBS EFBS EFB10S EFBFF

4 WALKERFLEX SYSTEM WIRIN DIARAMS 10V 0A SYSTEM FOR 1,, OR LINE S CONNECTED TO A ROUNDED 10V 0A SYSTEM FOR 1 OR LINE S CONNECTED TO A DUAL NEUTRAL ROUNDED AND ISOLATED ROUND 10V 0A SYSTEM FOR 1 OR LINE S CONNECTED TO A DUAL NEUTRAL ROUNDED 10V 0A SYSTEM FOR 1 OR LINE S CONNECTED TO A ROUNDED AND ISOLATED ROUND V 0A SYSTEM FOR 1,, OR LINE S CONNECTED TO A ROUNDED V 0A SYSTEM FOR 1 OR LINE S CONNECTED TO A DUAL NEUTRAL ROUNDED AND ISOLATED ROUND V 0A SYSTEM FOR 1 OR LINE S CONNECTED TO A DUAL NEUTRAL ROUNDED V 0A SYSTEM FOR 1 OR LINE S CONNECTED TO A ROUNDED AND ISOLATED ROUND L1 Black

5 WALKERFLEX SYSTEM WIRIN DIARAMS (continued) 10V 0A SYSTEM FOR LINE S & NEUTRALS CONNECTED TO AN ISOLATED ROUND 10V 0A SYSTEM FOR LINE S & NEUTRALS CONNECTED TO AN ISOLATED ROUND 10V 0A SYSTEM FOR LINE S & NEUTRALS CONNECTED TO AN ISOLATED ROUND 10V 0A SYSTEM FOR LINE S & NEUTRALS CONNECTED TO AN ISOLATED ROUND 10V 0A SYSTEM FOR LINE S & NEUTRALS CONNECTED TO A 0V 0A SYSTEM FOR 1,, OR LINE S CONNECTED TO A

6 WALKERFLEX SYSTEM WIRIN CONFIURATIONS WALKERFLEX - KEY CONFIURATIONS WALKERFLEX -10 KEY CONFIURATIONS TERMINAL BLOCK SYSTEM COLOR KEY POWER OUT POWER IN 0A, 10V Black A 1 1 TERMINAL BLOCK SYSTEM COLOR KEY POWER OUT POWER IN 0A, Black 10V, H/N/I 0A, 10V, Orange B I 1 1 0A, Orange 10V, H/N/I A, 10V, Clear C N 1 1 0A, Natural 10V, H/N/I A, V Yellow D 0A, Blue 1 10V, H/N/ A, V, reen E I 0A, Ivory 10V, H/N/I A, V, Blue F N 0A, 0V ray -10 SYSTEM KEYIN CONFIURATIONS & COLORS H N TERMINAL BLOCK WIRE WIRE WIRE SYSTEM COLOR KEY CONFI COLOR COLOR COLOR 10V Black Line 1: Black Neutral 1: White 1 Equip nd: reen H/N/I Line : Red Neutral : Wht/Red ISO nd: rn/yel 9 Line : Blue 10 Line : Blk/Wht 10V Orange Line 1: Black Neutral 1: White 1 Equip nd: reen H/N/I Line : Red Neutral : Wht/Red ISO nd: rn/yel 9 Line : Blue Neutral : Wht/Blu 10 Line : Blk/Wht Neutral : Wht/Blk 10V Natural Line 1: Black Neutral 1: White 1 Equip nd: reen H/N/I Line : Red Neutral : Wht/Red ISO nd: rn/yel 9 Line : Blue Neutral : Wht/Blu 10V Blue 1 1 Line 1: Black Neutral 1: White 1 Equip nd: reen H/N/ Line : Red Neutral : Wht/Red Line : Blue Neutral : Wht/Blu Line : Blk/Wht 9 Line : Red/Wht 10 Line : Blu/Wht 10V Ivory Line 1: Black Neutral 1: White 1 Equip nd: reen H/N/I Line : Red Neutral : Wht/Red ISO nd: rn/yel Line : Blue Line : Blk/Wht 9 Line : Red/Wht 10 Line : Blu/Wht

7 WALKERFLEX SYSTEM WIRIN CONFIURATIONS (continued) - SYSTEM KEYIN CONFIURATIONS & COLORS H N TERMINAL BLOCK WIRE WIRE WIRE COLOR KEY CONFI COLOR COLOR COLOR Black A Line 1: Black Neutral 1: White Equip nd: reen 11 1 Line 1: Black Neutral 1: White Equip nd: reen 11 1 Line 1: Black Neutral 1: White Equip nd: reen Line : Blue 11 1 Line 1: Black Neutral 1: White Equip nd: reen Line : Blue Line : Blk/Wh Orange B 11 1 Line 1: Black Neutral 1: White Equip nd: reen ISO nd: rn/yel 1 1 Line 1: Black Neutral 1: White Equip nd: reen ISO nd: rn/yel 1 Line 1: Black Neutral 1: White Equip nd: reen Neutral : Wht/Red ISO nd: rn/yel Clear C 1 1 Line 1: Black Neutral 1: White Equip nd: reen Neutral : Wht/Red Yellow D Line 1: Black Neutral 1: White Equip nd: reen 11 1 Line 1: Black Neutral 1: White Equip nd: reen 11 1 Line 1: Black Neutral 1: White Equip nd: reen Line : Blue 11 1 Line 1: Black Neutral 1: White Equip nd: reen Line : Blue Line : Blk/Wh reen E 11 1 Line 1: Black Neutral 1: White Equip nd: reen ISO nd: rn/yel 1 1 Line 1: Black Neutral 1: White Equip nd: reen ISO nd: rn/yel 1 Line 1: Black Neutral 1: White Equip nd: reen Neutral : Wht/Red ISO nd: rn/yel Blue F 1 1 Line 1: Black Neutral 1: White Equip nd: reen Neutral : Wht/Red ray Line 1: Black Neutral 1: White Equip nd: reen 11 1 Line 1: Black Neutral 1: White Equip nd: reen 11 1 Line 1: Black Neutral 1: White Equip nd: reen Line : Blue

8 N O T E S WIREMOLD U.S. and International: 0 Woodlawn Street West Hartford, CT FAX 0--0 Outside U.S.: 0--1 Canada: 0 Applewood Crescent Vaughan, Ontario LK B FAX Copyright 011 Legrand All Rights Reserved R 011

Walkerflex Modular Wiring System

Walkerflex Modular Wiring System New Walkerflex Modular Wiring System Offers Labor Savings Compared To Hard-Wired Systems Wiremold Walkerflex Modular Wiring System is a factory assembled connector and cable set system, designed to interface

More information

RC3, RC7 & RC4 Receptacle Replacement

RC3, RC7 & RC4 Receptacle Replacement RC3, RC7 & RC4 Receptacle Replacement INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 003 786R1 Updated October 2003 Walker electrical systems conform to and should be properly grounded in compliance

More information

F E A T U R E S & B E N E F I T S. ED755R13 Updated September 2011 For latest specs visit

F E A T U R E S & B E N E F I T S. ED755R13 Updated September 2011 For latest specs visit New Walkerflex Modular Wiring System Offers Labor Savings Compared To Hard-Wired Systems Wiremold Walkerflex Modular Wiring System is a factory assembled connector and cable set system, designed to interface

More information

WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES.

WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES. 1 WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES. 1 BOX. MULTIPLE FLOOR TYPES AND SURFACES. Wood Floor Concrete Floor Raised Floor 1 BOX. 6 FINISHES. Carpet, tile, wood, terrazzo and polished concrete

More information

WIREMOLD Pancake Overfloor Raceway

WIREMOLD Pancake Overfloor Raceway WIREMOLD Pancake Overfloor Raceway Steel Pancake Overfloor Raceway Pancake Overfloor Steel Raceway is ideal for open space wiring of workstations and desk areas in high traffic sites. Both the 1500 and

More information

Bring power safely and conveniently to wherever

Bring power safely and conveniently to wherever Plug-In Outlet Center Units Plug-In Outlet Center Units Bring power safely and conveniently to wherever you need it with a full line of Plug-In Outlet Center Units from Wiremold/Legrand. These units are

More information

The selection of lengths and fittings in a variety of

The selection of lengths and fittings in a variety of Plugmold Systems Steel Plugmold Raceway & Multioutlet Assemblies The selection of lengths and fittings in a variety of finishes provides a versatile solution for many applications. Plugmold sections offer

More information

WIREMOLD Ratchet-Pro Series Floor Boxes

WIREMOLD Ratchet-Pro Series Floor Boxes WIREMOLD Ratchet-Pro Series Floor Boxes Wiremold Single & Dual-Service Round Floor Boxes Wiremold Ratchet-Pro Series Floor Boxes provide single- and dual-service capability in a variety of easyto-install

More information

Poke-Thru Devices from Wiremold/ Legrand provide

Poke-Thru Devices from Wiremold/ Legrand provide Chicago Approved Poke-Thru Devices Bring High Capacity Power and Communication Services to Above Grade Open Space Areas Protection from water, dirt, and debris. Poke-Thru Devices from Wiremold/ Legrand

More information

Evolution Series Poke-Thru Devices

Evolution Series Poke-Thru Devices Wiremold Evolution Series Poke-Thru Devices are the latest addition to the largest offering of poke-thru solutions available in the industry. Combining new models that provide larger capacity options,

More information

Convention Center Series Products

Convention Center Series Products Convention Center Series Products Large Capacity, Multi-Utility Products Protection from water, dirt, and debris. Wiremold Convention Center Series Products are industry leading solutions for providing

More information

Introducing the next generation in

Introducing the next generation in Innovative Raceway Profile Provides Increased Wiring Capacity Available Factory Prewired 4000 Designer Series Steel Raceway Introducing the next generation in innovative surface raceway systems. The new

More information

WIREMOLD. Aluminum Single Channel Raceway. Aluminum Raceway. Available Factory Prewired.

WIREMOLD. Aluminum Single Channel Raceway. Aluminum Raceway. Available Factory Prewired. Aluminum Single Channel Raceway Available Factory Prewired. WIREMOLD Aluminum Raceway Isoduct ALA3800 Series Aluminum Raceway System meets the demands of commercial spaces, providing a handsome and effective

More information

The newly redesigned FloorPort

The newly redesigned FloorPort FloorPort Service Fittings & Accessories New Redesigned FloorPort Service Fittings Supply the Versatile Workstation Protection from water, dirt, and debris. The newly redesigned FloorPort Service Fittings

More information

Metal Raceway Systems. tomorrow. Wiremold Metal Raceway. Innovative from Day One.

Metal Raceway Systems. tomorrow. Wiremold Metal Raceway. Innovative from Day One. Metal Raceway Systems tomorrow 1916 Wiremold Metal Raceway. Innovative from Day One. Wiremold metal raceway has been defining the category for close to a century. Offering the broadest, most innovative

More information

More innovative solutions for an ever-evolving world. Electric Vehicle Chargers

More innovative solutions for an ever-evolving world. Electric Vehicle Chargers More innovative solutions for an ever-evolving world. Electric Vehicle Chargers Reliable EV charging solutions from an electrical innovator you can trust. Electric vehicles (EVs) are hitting the road in

More information

Information technology professionals in the Department of

Information technology professionals in the Department of Data-Fense Secure Raceway System Enhanced Protection of Critical Networks For Government, Financial Institutions, and R&D Facilities Information technology professionals in the Department of Defense, government

More information

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR DIVISION 16 - ELECTRICAL SECTION 16xx0 16xx0-1. GENERAL MANUFACTURED WIRING SYSTEM ACCESS FLOOR The modular convenience power system ensures the electrification and delivery of power from the power panels

More information

ED923R7 Updated April 2011 For latest specs visit

ED923R7 Updated April 2011 For latest specs visit Modulink 880MP Series Floor oxes 880MP Series Nonmetallic Floor oxes FIER OPTIC CT5 Wiremold Modulink 880 Series Nonmetallic Floor oxes provide power and communication services directly to the workstation

More information

Modulink. Wiremold 880MP Series Nonmetallic Floor Boxes. 880 Series Floor Boxes

Modulink. Wiremold 880MP Series Nonmetallic Floor Boxes. 880 Series Floor Boxes Modulink 880 Series Floor Boxes Wiremold 880MP Series Nonmetallic Floor Boxes Wiremold Modulink 880 Series Nonmetallic Floor Boxes provide power and communication services directly to the workstation or

More information

WIREMOLD Service Fittings

WIREMOLD Service Fittings WIREMOLD Service Fittings ctivations for Every pplication! Walkerduct Pro Series Service Fittings offer a complete range of service fittings to meet all power, data and communication requirements. The

More information

A 120V 20A Gfci RCPT. Features. Dimensions and Weight. Description. Manufacturer Information PASS & SEYMOUR GTIN

A 120V 20A Gfci RCPT. Features. Dimensions and Weight. Description. Manufacturer Information PASS & SEYMOUR GTIN 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1597 15A 120V 20A Gfci RCPT Pass & Seymour/Legrand Catalog Number 1597 Manufacturer Pass & Seymour/Legrand Description

More information

880W Series. Rectangular Floor Boxes for Wood Floors. Floor Boxes for Wood Floors

880W Series. Rectangular Floor Boxes for Wood Floors. Floor Boxes for Wood Floors Rectangular Floor Boxes for Wood Floors 880W Series Floor Boxes for Wood Floors Wiremold 880W Series Wood Floor Boxes provides an excellent solution for unique wood floor applications when power and communication

More information

F E A T U R E S & B E N E F I T S

F E A T U R E S & B E N E F I T S Multi-Compartment Surface Metal Raceway AnySize Raceway allows you to precisely size surface raceway to meet specific wiring capacity needs. Simply choose the material and finish you want, then specify

More information

Premium industrial grade isolated ground straight blade receptacles

Premium industrial grade isolated ground straight blade receptacles Technical Data Description 2-Pole, 3-Wire Grounding 15A 125V; 15A 250V 20A 125V; 20A 250V NEMA 5-15, 5-20, 6-15, 6-20 IG5261 AHIG5362 Design features Exclusive screw terminal guards provide fast, easy

More information

FAS power pre-fabricated. catalog

FAS power pre-fabricated. catalog 2011 FAS power pre-fabricated wiring assemblies catalog FAS Power reduces labor costs a minimum of 50% Easy to order Easier to install If you are constructing a hospital, condominium complex, office building

More information

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6

More information

Now you can precisely size surface raceway to

Now you can precisely size surface raceway to AnySize Raceway AnySize Multi-Compartment Surface Metal Raceway Now you can precisely size surface raceway to meet your wiring capacity needs. Simply choose the material and finish you would like, then

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

FloorPort Series. Redesigned Service Fittings Supply the Versatile Workstation. Service Fittings

FloorPort Series. Redesigned Service Fittings Supply the Versatile Workstation. Service Fittings FloorPort Series Service Fittings Redesigned Service Fittings Supply the Versatile Workstation TOPGUARD A/V INTEGRATION The newly redesigned FloorPort Service Fittings for Resource RFB Series Floor Boxes,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PowerSwitch Enclosed Disconnect Switch with Receptacle (EDSR) Cat. o. EDSR Rated: 30A-600VAC Max. ISTALLATIO ISTRUCTIOS DI-000-0EDSR-00A EDSR Enclosed Disconnect Switch with Receptacle (Figure 4) OTE:

More information

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-BFV.KIT Butterfly Valve Gear Operator Replacement SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before

More information

Arrow Hart hospital grade GFCI modular receptacles

Arrow Hart hospital grade GFCI modular receptacles Technical Data Arrow Hart hospital grade GFCI Description 2-pole, 3-wire grounding 15A 125V/AC 20A 125V/AC TAMPER RESISTANT SGFH20_MOD Design features ArrowLink modular plug and connector incorporate a

More information

WIREMOLD Wallduct Raceway Systems

WIREMOLD Wallduct Raceway Systems WIREMOLD Wallduct Raceway Systems Raceway Solutions for Healthcare pplications Wallduct Raceway Systems are high capacity raceways for use in walls or ceilings. They can be mounted to the wall surface

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

Installation Instructions Central Battery Units

Installation Instructions Central Battery Units Phone: 605.542.4444 concealite.com! Installation Instructions s Please Save These Instructions Important Safeguards Read and Follow All Safety Instructions When using electrical equipment, basic safety

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

FIRE CLASSIFIED FLOOR BOXES Omnibox Series Floor Boxes

FIRE CLASSIFIED FLOOR BOXES Omnibox Series Floor Boxes FIRE CLASSIFIED Omnibox Series Floor Boxes OmniBox Series Floor Boxes Solid Brass Cover Plate Flanges Ordering Information 817B One-Gang Brass Combination adapters and Wiremold CM Series 4 3/4" 880CS1-1

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw 30A 208V 20A 208V 3 Phase 30A 208V 3 Phase Important Information Specifications Installation & Operation Outline & Wiring Drawings

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 2095TRWRI 20A 125V Spec TR & WR Gfci Rec Pass & Seymour/Legrand Catalog Number 2095TRWRI Manufacturer Pass & Seymour/Legrand

More information

Cellwatch Electrical Installation

Cellwatch Electrical Installation Tech20081110-1-1 Cellwatch Electrical Installation Critical Distances...2 Typical Layout...3 Typical ibmu Placement...4 Typical Control Unit Placement...5 Physical Mounting and Location - General...6 CU

More information

Commercial grade straight blade receptacles

Commercial grade straight blade receptacles Technical Data Description 2-Pole, 3-Wire Grounding 15A 125V/AC; 15A 250V/AC 20A 125V/AC; 20A 250V/AC NEMA 5-15, 5-20, 6-15, 6-20 Design features Galvanized steel, wrap-around yoke mounting strap for superior

More information

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com G20GB12 Gry 3W1CKT Plugmold Wiremold/Legrand Catalog Number Manufacturer Description Weight

More information

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 2095 20A 120V BR GFI Recpt. Pass & Seymour/Legrand Catalog Number 2095 Manufacturer Pass

More information

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory Control Reliable Double Valves Safety Exhaust (Dump) DM Series D Self Monitored - Clutch/rake Control asic Size,,, and 0 Dynamic Monitoring With Complete Memory: Memory, monitoring, and air flow control

More information

WIREMOLD Fire Classified Floor Boxes

WIREMOLD Fire Classified Floor Boxes Legrand takes Wiremold floor boxes to the next level with the introduction of seven recessed and flush style f l o o r b o x m o d e l s t h a t m e e t o r e x c e e d U L F i re Classification requirements.

More information

MF Series MS Series

MF Series MS Series MF41-6043 Series MS41-6043 Series DuraDrive Non-Spring Return Direct Coupled Actuator General Instructions Figure-1 Parts of the DuraDrive Rotary Actuator. Product Description These installation instructions

More information

Commercial grade straight blade duplex receptacles

Commercial grade straight blade duplex receptacles Description 2-Pole, 3-Wire Grounding 15A 125V/AC; 15A 250V/AC 20A 125V/AC; 20A 250V/AC NEMA 5-15, 5-20, 6-15, 6-20 BR15 Design features Galvanized steel, wrap-around yoke mounting strap for superior assembly

More information

TRANSMISSION SYSTEMS

TRANSMISSION SYSTEMS TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

G20GB606 PLGMD 6'SGL CRT 6" 2000 Gray. Manufacturer Information. Packaging Carton 1 Package 2 Weight Per each Description

G20GB606 PLGMD 6'SGL CRT 6 2000 Gray. Manufacturer Information. Packaging Carton 1 Package 2 Weight Per each Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 G20GB606 PLGMD 6'SGL CRT 6" 2000 Gray Wiremold/Legrand Catalog Number G20GB606 Manufacturer Wiremold/Legrand Description

More information

DC400 Dispensing Cutoff System

DC400 Dispensing Cutoff System DC400 Dispensing Cutoff System Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Important

More information

RF Point Level Control with Sensor Monitor

RF Point Level Control with Sensor Monitor The 681 Point Level Control utilizes DPDT relays to provide switching for peripheral devices (such as pumps) in level applications. A sensor attached to the control acts as an antenna to transmit the process

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Interlock Switches Key features: Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening

More information

Model (Circuit Tester) Model (GFCI Tester)

Model (Circuit Tester) Model (GFCI Tester) User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Receptacle Testers Model 20250-61 (Circuit Tester) Model 20250-62 (GFCI

More information

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical

More information

Recipient Runner 3VZE R150 manual 5-speed 4WD - IFS Donor 1997 T-100 5VZ-FE R150 manual 5-speed 4WD - IFS

Recipient Runner 3VZE R150 manual 5-speed 4WD - IFS Donor 1997 T-100 5VZ-FE R150 manual 5-speed 4WD - IFS Recipient 1988 4Runner 3VZE R150 manual 5-speed 4WD - IFS Donor 1997 T-100 5VZ-FE R150 manual 5-speed 4WD - IFS Note: this wiring diagram is recipient and donor specific. Chances are that the color/pin

More information

GFCI RECEPTACLES PASS & SEYMOUR MORE SOLUTIONS FOR MORE SAFETY

GFCI RECEPTACLES PASS & SEYMOUR MORE SOLUTIONS FOR MORE SAFETY PASS & SEYMOUR GFCI RECEPTACLES MORE SOLUTIONS FOR MORE SAFETY LEGRAND KEEPS THE INNOVATIONS COMING At Legrand, we ve been providing real solutions to real problems for so long, it s almost second nature.

More information

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions QS Rule Raritan PX Power Cord Installation Guide This installation guide explains how to install power cords on Raritan PX products that do not come with a factory installed power cord. This type of product,

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) Installation Guide VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) VICPA222 Technical Data Power 24 Vac ±20%, 50/60 Hz Power consumption 8 VA (running)

More information

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide, Part number 123518-6 Copyright 2010,

More information

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems Conduit and Wire Must be scrapped whenever reconfiguration of the electrical layout is needed. Many runs may be needed for applications with a high volume or high density of electrical loads. It is labor

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

More information

LEV/Wn Building A Connected World

LEV/Wn Building A Connected World LEV/Wn Building A Connected World PK-93370-10-00-2B Installing and Testing a GFCI Please read this leaflet completely before getting started. A CAUTION To prevent severe shock or electrocution always turn

More information

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Owner s Manual For Automatic Transfer Switch 50 & 100 Amp Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Register your Generac product at: WWW.GENERAC.COM 888-436-3722

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

IMPORTANT SAFEGUARDS

IMPORTANT SAFEGUARDS INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,

More information

HBDBM High Bay Series

HBDBM High Bay Series HBDBM High Bay Series INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 25 feet. The fixture can be mounted with a hook or pendant with flexible adjustments

More information

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: This Product is Listed by UNDERWRITERS LABORATORIES INC. and Bears the Mark: This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: SLATER SCD Installation Instructions For Self-Contained

More information

DZ-03 Base Installation and Operation Manual

DZ-03 Base Installation and Operation Manual (Issue 1.0, August 2004) CONTENTS I General... 1 II Technical Specifications... 1 III Mounting and... 1 IV Cautions... 3 I General is used to mount conventional and intelligent smoke, heat and combination

More information

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:

More information

Posi-Lok Plugs and Panels

Posi-Lok Plugs and Panels FEMALE PANEL PART NUMBERS RECEPTACLES PER PANEL FEMALE PANELS COVER COLOR CODE 3 E0400-1685 GR, WH, BK 4 E0400-1686-NN GR, BK, RD, BU 4 E0400-1696 GR, WH, BK, RD 4 E0400-1883-NN GR, BRN, ORG, YEL 5 E0400-1687

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

Ideal for surface mounting

Ideal for surface mounting One-Piece Surface Steel Raceway V500 /V700 /700H Steel Raceway Ideal for surface mounting small amounts of electrical wiring or communication cables. These rugged raceways offer a low profile appearance

More information

Condenser Fan Pak Installation and Wiring Guide

Condenser Fan Pak Installation and Wiring Guide Condenser Fan Pak Installation and Wiring Guide 2200IB1501 Make the most of your energy SM Condenser Fan Pak: Installation and Wiring Guide p The purpose of this document is to illustrate the recommended

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Mazda For Models With Manual Climate Controls TOOLS REQUIRED:

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Mazda For Models With Manual Climate Controls TOOLS REQUIRED: INSTALLATION INSTRUCTIONS FOR PART 99-7509 APPLICATIONS Mazda 5 2006-2007 For Models With Manual Climate Controls 99-7509 KIT FEATURES Painted To Match Factory Dash DIN Radio Provision with Pocket ISO

More information

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO) Owner s Manual Series 165P Power Transfer Load Center 125 amps, 1 phase, 240 V ac, 12 or 20 load spaces for automatic 2 wire start generators DANGER is used in this manual to warn of risk of electrical

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16140 - WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Electric Actuator Instructions

Electric Actuator Instructions BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw Modular, scalable, high efficiency power protection for data centers. The Schneider Electric Symmetra TM PX 250/500 UPS provides high-performance,

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

Recp Duplex 20A 250V 2P3W STR Swire WH

Recp Duplex 20A 250V 2P3W STR Swire WH 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 815WB0X Recp Duplex 20A 250V 2P3W STR Swire WH Eaton Wiring Devices Catalog Number Manufacturer Description Weight per

More information

East Central College

East Central College SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Wall switches. b. Receptacles c. Device plates and decorative box covers. 1.2 RELATED

More information

Wall Mount Installation Manual

Wall Mount Installation Manual SOLARSHEAT 1000G/ G/1500G-GS Wall Mount Installation Manual By Your Solar Home, Inc. Version 1.0 August 0, 008 All building, plumbing, electrical and safety codes supersede the instructions in this manual.

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information