1 AIR COMFORT AIR DISTRIBUTION ROUND DUCTING» PRODUCT CATAOGUE

2

3 VEODUCT - Product Catalouge 3 CONTENTS PRODUCT DESIGNATIONS Duct VEOFEX...8, 26 Joint... 9 Insertion joint Bend 15, 30, 45, 60, Bend for cleaning T-piece and Cross , 56 T-piece and Cross, reversed T-piece, short...26 T-piece, Veloflex...26 T-piece and Cross, Branch , 49, 57 Reducer Reducer, long d...43 Cleaning cover Branch for insulation...49 Weathering cowl...50 Ceiling and wall branch...50 Inlet cone with protective net Branch with mesh...52 Supply air nozzle...53 Flange...54 Bracket...54 Protective cap...55 Adjustment and shut-off damper VEODUCT - General Dimensions and tolerances...63 Pressure drop charts Ducts Bends Reducers Branches, T-pieces and Crosses Installation instructions PRODUCT CODES BDB...48 BDEA * BDEB * BDEC *...49 BDED * BDEF BDEG * BDEK...4 BDEM *... 9 BDEN * BDEP * BDET, BDEX * BDEV, BXEV BDEZ... 50, 55 BDKE...18 BDKF *...42 BDK * BDKP BDKU *...51 BDSK...54 EBGA...54 EKOD... 5 ESAD *... 6 FEK... 8 FEX... 8 FET...26 XBEZ... 50, 53 XCEA...57 XCEK...7 XCET...56 XDEA...52 XDEZ...49 *) CE marked (smoke control duct system) according to EN :2011, EC Certificate of Conformity 0761-CPD-0277

4 4 VEODUCT - Product Catalouge DUCT BDEK - CIRCUAR DUCT a BDEK-a- a = length 1 = 3,00 m 2 = 6,00 m 4 = optional length between 1,00 and 6,00 m 5 = 3,00 m, liquid-tight seam DUCT PROFIE Sizes BDEK-a- Weight kg/m Sizes BDEK-a- Weight kg/m

5 VEODUCT - Product Catalouge 5 DUCT EKOD - CIRCUAR DUCT WITH PASTIC PROTECTIVE CAP EKOD-a--1 a = length 3 = 3,00 m 6 = 6,00 m 4 = optional length between 1,00 and 6,00 m DUCT PROFIE Sizes EKOD-a--1 t Weight mm kg/m Sizes

6 6 VEODUCT - Product Catalouge DUCT ESAD - SMOKE CONTRO DUCT Fläkt Woods Oy ESAD CE marked SMOKE CONTRO DUCT Fläkt Woods Oy ESAD C ESAD-a--1 a = length 3 = 3,00 m DUCT PROFIE ESAD-a--1 t Weight mm kg/m Sizes Sizes ESAD-a--1 t Weight mm kg/m

7 VEODUCT - Product Catalouge 7 SPIRA DUCT FOR EMBEDDING XCEK SPIRA DUCT FOR EMBEDDING IN CONCRETE, FIT-ON D XCEK-1- D Weight, t Value for deformation nom. m kg mm limit at vaccum, kpa

8 8 VEODUCT - Product Catalouge DUCT VEOFEX FEK - SPIRA TUBE, ENGTH 1150 MM FEX -TEESKOPIC TUBE aaa-012 aaa-040 FEK-aaa-120 Weight kg aaa-120 FEX-aaa- ength ength Weight, max min kg

9 VEODUCT - Product Catalouge 9 JOINT BDEM-1 BDEM-4 - ONG JOINT, BDEM-4--K, ONG JOINT FOR FIT-ON INSERTION CEANING, FIT-ON INSERTION 200 p p BDEM-1- p Weight, BDEM-4- p Weight, BDEM-4--K p Weight, BDEM-1- p Weight, BDEM-4- p Weight,

10 10 VEODUCT - Product Catalouge INSERTION JOINT BDEN-1 BDEN-4 - ONG INSERTION JOINT BDEN-3 - ONG INSERTION JOINT 200 i i i BDEN-1- Weight, BDEN-4- Weight, BDEN-3- Weight, BDEN-1- Weight, BDEN-4- Weight,

11 VEODUCT - Product Catalouge 11 BEND BDEB 15 - PRESSED BDEB 15 - FABRICATED BDEB-15- r Weight, mm BDEB-15- r Weight, mm BDEB-15- r Weight, mm

12 12 VEODUCT - Product Catalouge BEND BDEB 30 - PRESSED BDEB 30 - FABRICATED BDEB-30- r Weight, mm BDEB-30- r Weight, mm BDEB-30- r Weight, mm BDEB-30- r Weight, mm

13 i VEODUCT - Product Catalouge 13 BEND BDEB 45 - PRESSED BDEB 45 - FABRICATED r BDEB-45- r Weight, mm BDEB-45- r Weight, mm BDEB-45- r Weight, mm BDEB-45- r Weight, mm

14 14 VEODUCT - Product Catalouge BEND BDEB 60 - PRESSED BDEB 60 - FABRICATED BDEB-60- r Weight, mm BDEB-60- r Weight, mm BDEB-60- r Weight, mm BDEB-60- r Weight, mm

15 VEODUCT - Product Catalouge 15 BEND BDEB 90 - PRESSED BDEB 90 - FABRICATED i i r r BDEB-90- r Weight, mm BDEB-90- r Weight, mm BDEB-90- r Weight, mm BDEB-90- r Weight, mm

16 16 VEODUCT - Product Catalouge BEND BDEB 90 - SHORT, PRESSED BDEB 90 - SHORT, FABRICATED i i r r BDEB r Weight, mm BDEB r Weight, mm q, m 3 /h q, m 3 /h p t, Pa 10 Size A, db(a) q, l/s q, l/s

17 VEODUCT - Product Catalouge 17 BEND BDEB 90 - SHORT, PRESSED, FIT-ON INSERTION BDEB 90 - SHORT, FABRICATED, FIT-ON INSERTION p p i r r BDEB r p/ Weight, mm / / BDEB r p/ Weight, mm / / / / / q, m 3 /h q, m 3 /h pt, Pa 10 Size A, db(a) q, l/s q, l/s

18 18 VEODUCT - Product Catalouge BEND BDEB-90 - CEANABE BDKE - CEANABE BDEB r Weight, mm BDKE-aaa r C E Weight mm mm mm Δp t, Pa q, l/s Pressure drop with cleaning cover BDEG-2 or BDEG-3.

19 VEODUCT - Product Catalouge 19 T-PIECE AND CROSS BDET-1 - T-PIECE, PRESSED BRANCHES, CONCENTRIC BDEX-1 - CROSS, PRESSED BRANCHES, CONCENTRIC r ccc r ccc i i H H i BDE(T,X)-1--ccc H r Weight, Weight, BDET BDEX mm mm kg BDE(T,X)-1--ccc H r Weight, Weight, BDET BDEX mm mm kg / / / / / / / / / / / / / / / / / /

20 20 VEODUCT - Product Catalouge T-PIECE AND CROSS BDET-1 - T-PIECE, PRESSED BRANCHES, CONCENTRIC BDEX-1 - CROSS, PRESSED BRANCHES, CONCENTRIC BDE(T,X)-1--ccc H r Weight, Weight, BDET BDEX mm mm kg BDE(T,X)-1--ccc H r Weight, Weight, BDET BDEX mm mm kg / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /

21 VEODUCT - Product Catalouge 21 T-PIECE AND CROSS BDET-1 - T-PIECE, FABRICATED BRANCHES, CONCENTRIC BDEX-1 CROSS - FABRICATED BRANCHES, CONCENTRIC ccc ccc H H i i BDE(T,X)-1--ccc H Weight, Weight, BDET BDEX mm kg / / / / / / BDE(T,X)-1--ccc H Weight, Weight, BDET BDEX mm kg / / / / / / / / / / / / / / / /

22 22 VEODUCT - Product Catalouge T-PIECE AND CROSS BDET-2 - T-PIECE, FABRICATED BRANCHES, ECCENTRIC BDEX-2 - CROSS, FABRICATED BRANCHES, ECCENTRIC ccc ccc H H BDE(T,X)-2--ccc H Weight, Weight, BDET BDEX mm kg / / / / / / / / / / / / / / / / / / / / / / / /

23 VEODUCT - Product Catalouge 23 T-PIECE AND CROSS BDET-2 - T-PIECE, FABRICATED BRANCHES, ECCENTRIC BDEX-2 - CROSS, FABRICATED BRANCHES, ECCENTRIC ccc ccc H H BDE(T,X)-2--ccc H Weight, Weight, BDET BDEX mm kg / / / / / / / / / / / / / / / / / / / / / / / / BDE(T,X)-2--ccc H Weight, Weight, BDET BDEX mm kg / / / / / / / / / / / / / / / / / /

24 24 VEODUCT - Product Catalouge REVERSED T-PIECE BDET-1 - REVERSED T-PIECE, FABRICATED, CONCENTRIC ccc i H ccc BDET-1--ccc r Weight, mm / / / BDET-1--ccc r Weight, mm BDET-1--ccc r Weight, mm / / / / / / / / / / /

25 VEODUCT - Product Catalouge 25 REVERSED T-PIECE BDET-2 - REVERSED T-PIECE, FABRICATED, ECCCENTRIC ccc i H BDET-2--ccc r Weight, mm / / / BDET-2--ccc r Weight, mm BDET-2--ccc r Weight, mm / / / / / / / / / / /

26 26 VEODUCT - Product Catalouge T-PIECE BDET-3 - T-PIECE, SHORT, INSERTION - FIT-ON BDET-4 - T-PIECE, SHORT, FIT-ON - FIT-ON ccc ccc r i r H H i p p BDET-3--ccc H /p r Weight, mm mm / / / / BDET-4--ccc H /p r Weight, mm mm / / / / VEOFEX FET - T-PIECE, INSERTION - FIT-ON FET-aaa- H Weight, mm

27 VEODUCT - Product Catalouge 27 T-PIECE AND CROSS BDEV-1 - T-PIECE, 45 (TO THE EFT) BXEV-1 - CROSS, 45, CONCENTRIC (TO THE RIGHT) H ccc H ccc ccc B(D,X)EV-1--ccc H Weight, Weight, BDEV BXEV mm kg B(D,X)EV-1--ccc H Weight, Weight, BDEV BXEV mm kg / / / / / / / / / / / / / / / /

28 28 VEODUCT - Product Catalouge T-PIECE AND CROSS BDEV-1 - T-PIECE, 45 (TO THE EFT) BXEV-1 - CROSS, 45, CONCENTRIC (TO THE RIGHT) H ccc H ccc ccc B(D,X)EV-1--ccc H Weight, Weight, BDEV BXEV mm kg B(D.X)EV-1--ccc H Weight, Weight, BDEV BXEV mm kg / / / / / / / / / / / /

29 VEODUCT - Product Catalouge 29 T-PIECE AND CROSS BDEV-1 - T-PIECE, 45 (TO THE EFT) BXEV-1 - CROSS, 45, CONCENTRIC (TO THE RIGHT) H ccc H ccc ccc B(D.X)EV-1--ccc H Weight, Weight, BDEV BXEV mm kg / / / / / / / / / / / / / / / / / / / / / / / / B(D.X)EV-1--ccc H Weight, Weight, BDEV BXEV mm kg / / / / / / / / / / / / / /

30 30 VEODUCT - Product Catalouge BRANCH BDEA-1 - BRANCH, PRESSED, CONCENTRIC ccc ccc r r i H H BDEA-1--ccc H r Weight mm BDEA-1--ccc H r Weight mm , BDEA-1--ccc H r Weight mm

31 VEODUCT - Product Catalouge 31 BRANCH BDEA-1 - BRANCH, PRESSED, CONCENTRIC ccc r i H BDEA-1--ccc H r Weight mm BDEA-1--ccc H r Weight mm

32 32 VEODUCT - Product Catalouge BRANCH BDEA-1 - BRANCH, FABRICATED, CONCENTRIC ccc i H BDEA-1--ccc H Weight, BDEA-1--ccc H Weight,

33 VEODUCT - Product Catalouge 33 BRANCH BDEA-2 - BRANCH WITH FODING TABS AND SEA, SMA RADIUS AND POP-RIVETING EDGE r i BDEA-2- r Weight, BDEA-2- r Weight,

34 34 VEODUCT - Product Catalouge BRANCH BDEA-5 - BRANCH WITH RADIUS BDEA-6 - BRANCH WITH SMA RADIUS r i r Sizes pressed Sizes extruded sealing and Veloduct sealing r i Sizes fabricated Sizes Veloduct Twin sealing BDEA-5- r Weight, * * * BDEA-6- r Weight, *) normal Veloduct sealing BDEA-5- r Weight, BDEA-6- r Weight,

35 VEODUCT - Product Catalouge 35 REDUCER BDED-1 - REDUCER, CONCENTRIC, FIT-ON - INSERTION i ccc BDED-1--ccc Weight, * * * * * * * * * *) normal Veloduct sealing BDED-1--ccc Weight, , BDED-1--ccc Weight,

36 36 VEODUCT - Product Catalouge REDUCER BDED-3 - REDUCER, CONCENTRIC, INSERTION - INSERTION p ccc BDED-3--ccc p/ Weight, / / / / / / / / / / / / / / / * / * 95 60/ * 65 60/ * / * / * 90 60/ * / * / * / *) normal Veloduct sealing BDED-3--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / BDED-3--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /60 2.4

37 VEODUCT - Product Catalouge 37 REDUCER BDED-2 - REDUCER, ECCENTRIC, FIT-ON - INSERTION BDED-4 - REDUCER, ECCENTRIC, INSERTION - INSERTION p p ccc ccc BDED-2--ccc p/ Weight, mm kg / / / / / / / / / / / / / / / / / / BDED-4--ccc p/ Weight, / / / / / / / / / / / / / / / / / /95 8.7

38 38 VEODUCT - Product Catalouge REDUCER BDEF-1 - REDUCER, ONG, CONCENTRIC, FIT-ON - INSERTION p ccc BDEF-1--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /95 16 BDEF-1--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / BDEF-1--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /60 3.4

39 VEODUCT - Product Catalouge 39 REDUCER BDEF-2 - REDUCER, ONG, ECCENTRIC, FIT-ON - INSERTION p ccc BDEF-2--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /95 16 BDEF-2--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / BDEF-2--ccc p/ Weight, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /60 3.4

40 40 VEODUCT - Product Catalouge REDUCER BDEF-3 - REDUCER, ONG, CONCENTRIC, INSERTION - INSERTION i i ccc BDEF-3--ccc Weight, / / / / / / / / / / / / BDEF-3--ccc Weight, BDEF-3--ccc Weight, / / / / / / / / / / / / / / / / / / / / /

41 VEODUCT - Product Catalouge 41 REDUCER BDEF-4 - REDUCER, ONG, ECCENTRIC, INSERTION - INSERTION i i ccc BDEF-4--ccc Weight, / / / / / / / / / / / / BDEF-4--ccc Weight, BDEF-4--ccc Weight, / / / / / / / / / / / / / / / / / / / / /

42 42 VEODUCT - Product Catalouge REDUCER BDKF-2 - REDUCER, ECCENTRIC, FIT-ON - INSERTION BDKF-4 - REDUCER, ECCENTRIC, INSERTION - INSERTION p i ccc ccc BDKF-2--ccc(-T) p/ Weight, (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / (-T) / T in the code: separate packing (M1) BDKF-4--ccc(-T) Weight, (-T) / (-T) / (-T) / (-T) / (-T) / (-T) (-T) / (-T) (-T) (-T) / (-T) / (-T) / (-T) / (-T) / (-T) (-T) / (-T) (-T) T in the code: separate packing (M1)

43 VEODUCT - Product Catalouge 43 ID BDEG-1 - ID, FIT - ON BDEG-4 - ID, INSERTION p i BDEG-1- p Weight, mm kg ** ** ** **) Fabricated BDEG-4- Weight, * * ** ** ** *) Veloduct sealing **) Fabricated + Veloduct sealing BDEG-1- p Weight, mm kg BDEG-4- Weight,

44 44 VEODUCT - Product Catalouge CEANING COVER BDEG-2 - CEANING COVER, INSUATED, INSERTION BDEG-3 - CEANING COVER, INSERTION p p FIRE RESISTANCE CASS E 60 (EI 60) 1) FIRE RESISTANCE CASS E 60 (EI 60) 1) BDEG-2- p Weight, mm kg BDEG-3- p Weight, mm kg ) In accordance with BBR 5:6213, the cover may be used where components to fire resistance class EI 60 are re quired provided that the cover is installed at a min. dis tance of 500 mm from an escape route and at a min. dis tance of 200 mm from any combustible material. If the fire resistance requirement is EI 30, the cor re sponding protective distance must be at least 400 mm (escape route) and 150 mm (combustible material) respectively. THE TYPE APPROVA FOR FIRE RESISTANCE CASS DOES NOT APPY TO THE COMPONENT BEOW. XDEG-2- p Weight, mm kg ) In accordance with BBR 5:6213, the cover may be used where components to fire resistance class EI 60 are re quired provided that the cover is installed at a min. dis tance of 500 mm from an escape route and at a min. dis tance of 200 mm from any combustible material. If the fire resistance requirement is EI 30, the cor re sponding protective distance must be at least 400 mm (escape route) and 150 mm (combustible material) respectively. THE TYPE APPROVA FOR FIRE RESISTANCE CASS DOES NOT APPY TO THE COMPONENT BEOW. XDEG-3- p Weight, mm kg

45 VEODUCT - Product Catalouge 45 CEANING COVER BDEG-4 - CEANING COVER WITH HANDE, INSERTION BDEG-4 - CEANING COVER WITH HANDE, INSUATED, INSERTION BDEB-4--K Weight BDEG-4--KE Weight

46 46 VEODUCT - Product Catalouge CEANING COVER BDEG-7 - CEANING COVER WITH MOUNTING RING, INSUATED, INSERTION, BDEG-7- Weight, kg

47 VEODUCT - Product Catalouge 47 CEANING COVER BDK-1 - CEANING COVER FOR SUBSEQUENT INSTAATION ON CIRCUAR DUCT BDKP-3 - CEANING COVER, INSERTION Size Size of opening C185 ( ) 300 ( ) 400 ( ) 500 ( Size Size 125 BDK-1- B C Weight, BDKP-3- B C Weight, mm mm

48 48 VEODUCT - Product Catalouge CEANING COVER BDB-1 - CEANING COVER FOR SUBSEQUENT INSTAATION ON CIRCUAR DUCT, INSUATED A, As Cover cc Frame B Bs Seal BDB-1--cc cc = thickness of insulation (heat and fire) 03 = 30 mm 06 = 60 mm 04 = 40 mm 08 = 80 mm 05 = 50 mm 10 = 100 mm BDB-1--cc Opening (mm) Weight (kg) inner outer -cc (cm) - As Bs A B

49 VEODUCT - Product Catalouge 49 BRANCH BDEC-1 BRANCH XDEZ-05 BRANCH FOR INSUATION BDEC-1- Weight, BDEC-1- Weight, XDEZ Weight, mm kg XDEZ Weight, mm kg

50 50 VEODUCT - Product Catalouge WEATHERING COW & CEIING AND WA BRANCH XBEZ-71 - WEATHERING COW BDEZ-43 - CEIING AND WA BRANCH ød H 41 * * Fit-on measure that fits outside pipes or detail. The size of the plate is 255 x 255 mm and the hole size for the insertion branch is: XBEZ-71- ø D H Weight , , , , , ,4 BDEZ-43- mm PRESSURE DROP q, m 3 /h Size A, db(a) q, l/s

51 VEODUCT - Product Catalouge 51 INET CONE WITH PROTECTIVE NET BDKU - INET CONE WITH PROTECTIVE NET EXTRACT AIR q, m 3 /h p10a, db(a) p t, Pa BDKU-aaa A Weight, mm q v, l/s SUPPY AIR q, m 3 /h p10a, db(a) p t, Pa q v, l/s

52 52 VEODUCT - Product Catalouge BRANCH WITH MESH XDEA-5 BRANCH WITH MESH XDEA-6 BRANCH WITH MESH i i r XDEA r Weight, , XDEA Weight, mm kg

53 VEODUCT - Product Catalouge 53 SUPPY AIR NOZZE XBEZ-72 SUPPY AIR NOZZE ø i 60 XBEZ-72- Weight, mm kg q, m 3 /h Size 30 A, db(a) 25 pt, Pa q, l/s

54 54 VEODUCT - Product Catalouge FANGE & BRACKET EBGA-2 - FANGE, GAVANIZED (SIZES EUROVENT 1/2) BDSK BRACKET, GAVANIZED ØG - n pieces Sizes Sizes EBGA-2- Ds E T H G n Weight, mm mm mm mm mm kpl kg BDSK-aaa Ds ØG T Weight, mm mm

55 VEODUCT - Product Catalouge 55 PROTECTIVE CAP BDEZ PASTIC PROTECTIVE CAP, PUSHED DIMENSION INSERTION BDEZ-02- Weight, mm kg

56 56 VEODUCT - Product Catalouge T-PIECE WITH DIFFUSER MOUNTING RING, OW HEIGHT XCET T-PIECE WITH DIFFUSER MOUNTING FRAME, OW HEIGHT d2 r H d 1 Product code d 1 d 2 H r Weight, nom. nom. mm mm XCET

57 VEODUCT - Product Catalouge 57 BRANCH XCEA BRANCH, INSERTION, WITH NAI FANGE XCEA BRANCH, INSERTION, WITH DIFFUSER MOUNTING FRAME, INTENDED FOR FACTORY CASTING FIIGRANBRANCH XCEA BRANCH, INSERTION, WITH NAI FANGE, INTENDED FOR FACTORY CASTING FIIGRANBRANCH D D D p Product code D Weight, nom. mm kg XCEA XCEA XCEA Product code D Weight, nom. kg XCEA XCEA Product code D Weight, nom. kg XCEA XCEA XCEA

58 58 VEODUCT - Product Catalouge ADJUSTING DAMPER BDEP-1 Sizes Sizes BDEP-1--c A B Weight, mm mm BDEP-1--c A B Weight, mm mm PRESSURE DROP CHARTS BDEP-1, -10, -13, -18 AND α = α = Total pressure drop p t, Pa wt = 70 db Total pressure drop p t, Pa wt = 80 db Sizes Air velocity, m/s Air velocity, m/s 5 Sizes

59 VEODUCT - Product Catalouge 59 ADJUSTING AND SHUT OFF DAMPER BDEP-4 Sizes Sizes BDEP-4--c A B Weight, mm mm BDEP-4--c A B Weight, mm mm PRESSURE DROP CHARTS BDEP-4, -40, -43, -46, -48 AND -49 Total pressure drop p t, Pa α = wt = 70 db Total pressure drop p t, Pa α = wt = 70 db Air velocity, m/s 5 Sizes Air velocity, m/s 5 Size

60 60 VEODUCT - Product Catalouge ADJUSTING DAMPER WITH MOTOR CONTRO BDEP-10 AND BDEP-40 DAMPER WITH MOTOR BRACKET EXC. MOTOR BDEP-13 AND BDEP-43 BEIMO MOTOR TYPE M... A ON-OFF BDEP-aa- A Weight, kg (aa = 10 / 40) mm mm mm excl. motor BDEP-aa- A Weight, (aa = 13 / 43) mm

61 VEODUCT - Product Catalouge 61 ADJUSTING DAMPER WITH MOTOR CONTRO BDEP-18 AND BDEP-48 BEIMO MOTOR TYPE F WITH SPRING RETURN BDEP-46 BEIMO MOTOR TYPE SF WITH SPRING RETURN BDEP-aa- A Weight (aa = 18 / 48) mm , BDEP-aa- A Weight (aa = 46) mm BDEP-19 AND BDEP-49 BEIMO MOTOR TYPE SM... A ON-OFF BDEP-aa- A Weight (aa = 19 / 49) mm

62 62 VEODUCT - Product Catalouge GENERA The VEODUCT system is a complete system of round ducting for which type approval for tightness class D according to EN has been granted. All duct fittings are equipped with a sealing ring made of EPDM rubber. VEODUCT permits rapid, easy and clean installation can be installed in any climate easy to balance reduces operating cost made of fireproof sheet steel THE SEA The sealing principle is illustrated in the drawings below. These show an insertion fitting and a fit-on (tube) fitting. The seal is made of solid EPDM rubber and is fixed to the end of the fitting. The seal is highly resistant to moisture, airborne pollutants and solar radiation and can withstand continuous exposure to temperatures between -30 C and +80 C with an unimpaired function. DESIGN TYPE APPROVAS AND CERTIFICATES Tightness and strength type approvals SP Sveriges tekniska forskningsinstitut, number 1718/88, tightness class D 1) VTT Technical Research Centre of Finland, number VTT- RTH , tightness class C 1) Finnish M1 cleanliness Classification by The Building Information Foundation RTS 1) CE marked (smoke control duct system) according to EN :2011, EC Certificate of Conformity 0761-CPD ) 1) Certificates available at Veloduct sealing Veloduct Twin sealing Tube and fittings are marked with a type approval label.

63 VEODUCT - Product Catalouge 63 GENERA DIMENSIONS AND TOERANCES (AS PER EUROPEAN STANDARD EN 1506) t 1 D d D d 3 p Size D d d 3 A i, p t1 tube t1 tube, mm mm mm m 2 mm BDEK EKOD D Inner diameter, tubes and fit-on fittings d Outer diameter, insertion fittings d 3 Recommended diameter of opening A Cross-section area of duct Insertion length p Fit-on length t 1 Sheet metal thickness, tubes MATERIAS AND FINISH Pipes and pipe components are made of hot-dip galvanized sheet steel in accordance with EN with a zinc thickness of 275 g/m 2 (double sided). This sheet is suitable for use in an environment with corrosivity class C2 in accordance with ISO 9223 and/or environmental class M2 in accordance with VVS AMA 98. TOERANCES Sheet metal thickness according to SS-EN Weight ± 10% ength. The following tolerances are applicable to the basic dimensions specified. Basic dimensions, mm 15 (15) 100 > 100 Tolerance, mm The tolerance of the bends is ±2.

64 64 VEODUCT - Product Catalouge PRESSURE DROP CHARTS Basic calculation data for ducts and duct components having cross-section to Eurovent 2/3 and design to Eurovent 2/4. The rated nominal air flow resistance (pnom) should be corrected with regard to leakage and fan connection. ΣΔptot = Δp nom + Δp leakage + Δp fan conn. The air flow resistances are charted directly in Pa. The data in the charts refer to total pressure drop and are therefore direct measurements of the energy loss across the air flow resistances. (Pa = 1 J/m 3 ) The influence of the choice of velocity on the pressure drop can be judged directly. The difference in pressure drop between the first and the nth branch can be read directly. The effect of a transition in 1, 2 or 3 size steps can be read directly. DUCTS Size

65 VEODUCT - Product Catalouge 65 PRESSURE DROP CHARTS BDEB BEND, PRESSED The pressure drop in the chart refer to 90 bend. For 45 -, respectively. 30 bend the following applies: p t 45 = 0.5 * p t p t 30 = 0.33 * p t q, m 3 /h ,5 0,2 0,1 0, ,5 0,2 0,1 p t, Pa ,0 0,1 1 2 v, m/s q, l/s BDEB BEND, FABRICATED The pressure drop in the chart refer to 90 bend. For 45 -, respectively. 30 bend the following applies: p t 45 = 0.5 * p t p t 30 = 0.33 * p t q, m 3 /h ,5 0,5 1,0 0,2 0,1 0,2 0,05 0,1 0, q, l/s pt, Pa v, m/s

66 66 VEODUCT - Product Catalouge PRESSURE DROP CHARTS REDUCER, A TYPES 1 size step*) D1/D2 = size step*) D1/D2 = size step*) D1/D2 = 2.0 Area increase Area increase Area increase 100 Area decrease 100 Area decrease Area decrease p t, Pa 5 2 p t, Pa 5 2 pt, Pa Incoming v, m/s air velocity v, m/s Incoming v, m/s air velocity v, m/s Incoming v, m/s air velocity v, m/s *) Example: Transition from 020 to 016 = 1 size step. 020 to 012 = to 010 = 3

67 VEODUCT - Product Catalouge 67 PRESSURE DROP CHARTS BRANCHES, T-PIECES AND CROSSES The pressure drops included any reductions in cross section in accordance with the figures, provided that S < 3 D. D S S D

68 68 VEODUCT - Product Catalouge INSTAATION INSTRUCTIONS INSTAATION OF ROUND TUBES AND FITTINGS (TO TIGHTNESS CASS D) Fig. 1 THE TYPE APPROVA The Veloduct ducting system has been granted type approval by SITAC (the Swedish Institute for Technical Approval in Construction) in accordance with Type Approval Certificate 1718/88. The type approval signifies that a Veloduct ducting system, installed in accordance with this instruction, complies with the provisions of the Swedish aw (1994:847) on technical specification requirements for construction work, etc. In order for the type approval to be valid, it is required that all details be marked as shown in Fig. 1 or in a similar manner. Components without this seal of approval may only be employed to a limited extent and only if they are essential for connection to items of equipment or for special matching of the ducting to the building structure. The supervisor must check any components which do not bear the seal of approval with regard to the sealing employed and the installation.the sealing employed and the installation.

69 VEODUCT - Product Catalouge 69 INSTAATION INSTRUCTIONS INSTAATION OF ROUND TUBES AND FITTINGS (TO TIGHTNESS CASS D) PREPARATORY WORK PRIOR TO INSTAATION WARNING! Ventilation ducts made of thin sheet metal sometimes have razor-sharp edges. WEAR PROTECTIVE GOVES! Be especially careful with the following: cut edges of spiral ducts straight (non-folded) sheet metal edges of assembly parts. 3. Cut the tubes at right angles to the measured lengths (make allowance for the fitting lengths of the components), and deburr the tube ends thoroughly, using a file or a deburring tool. 1. Select a suitable section of ducting and check that the duct can be run in accordance with the drawing before collecting the necessary components from the storage area. Fig. 4 Fig Collect the necessary fittings and tubes. Check that they aren t damaged in any way that would cause air leakage in the finished ducting system, such as holes left after rivets/screws have been removed from reused parts. If the storage area is well arranged and has good weather protection, the components will be easier to find, and the risk of damage or wastage will be reduced. A sign such as that shown in Fig. 3 will facilitate the delivery of materials. Fig. 5 INSTAATION 4. Assemble suitable sections on the floor. To facilitete the fitting of one part into another, turn one of them while pushing it in. VEODUCT UPPAGSPATS Fig. 3 Fig. 6

70 70 VEODUCT - Product Catalouge INSTAATION INSTRUCTIONS INSTAATION OF ROUND TUBES AND FITTINGS (TO TIGHTNESS CASS D) SIZE COMPONENTS a) Minimum overlap = to edge of bead a 7. Fit the hangers (e.g. XCEZ-111 Veloduct hanger straps). The distance between hangers should not exceed 3.0 m for uninsulated ducts and 2.0 m for ducts with fire insulation. Fig. 7 SIZE COMPONENTS b) Minimum overlap = until the dimples centre to tube end b Fig Suspend the duct sections from the hangers. Fig Fit together the various components as shown in Fig. 7 and ock the joints. All joints must be secured by means of self-tapping screws or pop rivets in the ducts. The purchaser decides which fasteners can be utilised for ease of cleaning. The number of self-tapping screws or pop rivets necessary is specified in the table above. ocate the screws at such a distance from the tube end that the rubber seal will not be damaged. Space the screws equally around the periphery, and arrange them in such a manner that the gap between the tube and the fitting will be as small as possible. The ductwork can be locked with the tubes and fittings resting on the floor, or this can be done after the ducting has been suspended. The latter procedure facilitates adjustment of the overall length and the positions of various fittings. Duct size Number of screws/pop rivits Fig Insertion is facilitated if the entry end is located so that the seal will not be nipped. Fig Readjustment of Veloduct joints: If it becomes necessary to turn one or both duct components at their joint, and the rivets or screws securing it are removed, the rivet/screw holes left in the duct component will have to be sealed before the joint is relocked. Keep in mind that an open hole in the insertion end of the duct component will leak even though it is concealed by a tube or connection piece. Fig. 9

71 VEODUCT - Product Catalouge 71 INSTAATION INSTRUCTIONS INSTAATION OF ROUND TUBES AND FITTINGS (TO TIGHTNESS CASS D) 11. Removal of fittings or tubes: Turn the component while withdrawing since the seal will otherwise fold and render dismantling difficult. If sealing compound cannot be applied to the outside of the branch (e.g. in the case of a mounting frame), apply ad ditional sealing compound at the inner end of the branch (3). If the branch is accessible from the outside (item of equipment), spread out the compound which has been squeezed out (4). If necessary, apply additional compound until a uniform, sealing bead has been 1 Fig. 13 Fig. 14 a 2 INSTAATION OF PRODUCTS WITHOUT SEA OF APPROVA 12. Products without seal of approval incorporated into the ducting and fitted in accordance with the pro visions of the seal of approval must be sealed so that they will definitely be in conformance with tightness class D. The seal at joints, etc. must be checked visually before fitting into the ducting. A test report must be produced for products with concealed joint seals. Components not provided with VEODUCT seals must be sealed in accordance with relevant parts of the example below. The sealing material should be non-ageing and permanently elastic. Fig. 14 b 3 3 A) Mounting frames and branches for duct fittings and equipment branches (Fig. 14). Deburr the tube end (1). Apply an abundant coating of sealing agent to the end of the branch so that a bead of sealing agent will be formed (2). Push the branch into the tube. Secure the branch to the tube by means of self-tapping screws/blind rivets. Fig. 14 c 4

72 72 VEODUCT - Product Catalouge INSTAATION INSTRUCTIONS INSTAATION OF ROUND TUBES AND FITTINGS (TO TIGHTNESS CASS D) B) Securing of products to the building structure (Fig. 15). Check that the joint surface (1) is smooth. Apply a sealing strip to the joint surface of the pro duct (2). Secure the product to the building structure. Then seal the inside of the joint (3) or, if preferable, on the outside. Refinish with concrete or similar material, if necessary (4) C) Sealing of rectangular joint against items of equipment (transition from a circular duct to an item of equipment with a rectangular connection) as shown in Fig. 16. If possible, the circular connection (1) of the tran sition piece should be made by means of a VEODUCT joint. The rectangular joint (2) should be of the factory-made type and should be fitted in accordance with the manufacturer s instructions for tightness class C. A flanged joint (bolted joint) must be fitted with a nonageing sealing strip and external corners under the flange should be carefully sealed with sealing compound (3)

Marine Catalogue 2014

Marine Catalogue 2014 Photo copyright STX Finland Marine Catalogue Marine Catalogue 14 1 05.08.14 Fläkt Woods EN 14.05 All rights reserved. www.flaktwoods.com Marine Catalogue Content 3 Components Type BDE Uninsulated Type

More information

ACTIVENT System. Specifications. Product code example ACTA

ACTIVENT System. Specifications. Product code example ACTA Activent is a ventilation system for supplying and distributing air. The system has been proven to function effectively in both small and large areas and is used in all types of premises ranging from offices

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

OPTIVENT Housing HVSA, HVSL

OPTIVENT Housing HVSA, HVSL OPTIVENT Housing HVSA, HVSL Key features Variable air flow Constant air flow Real time air flow display with compact controller 227VM The HVSA and the HVSL are apartment-specific room ventilation regulators

More information

Fire dampers ETCE and ETCS TECHNICAL DATA

Fire dampers ETCE and ETCS TECHNICAL DATA Fire dampers ETCE and ETCS TECHNICAL DATA 2 Fire dampers ETCE and ETCS Veloduct ETCE fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 13662.

More information

Pressure control damper ERPA

Pressure control damper ERPA Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa) DYBA is a quiet, ceiling-mounted supply air unit that consists of a nozzle diffuser, DYBH, and an insulated plenum box, ATTC. The nozzles of the diffuser produce a swirl pattern, which provides a highly

More information

KSOF Fire damper valve

KSOF Fire damper valve KSOF Fire damper valve KSOF is developed for use as a fire damper valve in exhaust ventilation systems. Fire damper valve KSOF is CE marked based on product standard EN 156: and tested according to test

More information

Nozzle air diffuser DYSB

Nozzle air diffuser DYSB Nozzle air diffuser DYSB DYSB is a range of nozzle air diffusers with adjustable nozzles for the setting of an optional diffusion pattern, intended for ceiling installation. The devices are documented

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

Silencers. ALNOR systemy wentylacji. Download Wentyle Download AlnorCAM B2B ordering

Silencers. ALNOR systemy wentylacji. Download Wentyle Download AlnorCAM B2B ordering Download Wentyle Download AlnorCAM B2B ordering 410 ANOR reserves the right to modify technical specifications in line with the policy of continuous product improvement. http://www.alnor.com.pl/produkty_pl/kanaly-i-ksztaltki-okragle.html

More information

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm. Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are

More information

Combustion gas damper EKO-SRB

Combustion gas damper EKO-SRB Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey

More information

PUNKAH LOUVRES - PKL DESCRIPTION & FEATURES

PUNKAH LOUVRES - PKL DESCRIPTION & FEATURES PUNKAH LOUVRES - DESCRIPTION & FEATURES Punkah Louvres are suitable for high velocity spot cooling applications. The unit is fully adjustable and can be used as either a jet or diffused air outlet. Fully

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

PKI-C Cartridge Fire Dampers

PKI-C Cartridge Fire Dampers Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal

More information

Fire/smoke damper EKO-SRBG1

Fire/smoke damper EKO-SRBG1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

TUBE & BOX FAN - ACCESSORIES

TUBE & BOX FAN - ACCESSORIES 143 DS - ACK DRAUGHT DAMPER CFC - DUCT CAMPS Automatic back draught damper with flute mechanism for installation into the tube system. Opening in air stream, closing via flute power. Casing made of galvanized

More information

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C KTS Supply air valve KTS valve is a supply air valve for ceiling mounting in offices, houses etc. Quick Selection (50 Pa) Size Air flow range l/s at sound level 25 db 30 db 35 db KTS-100-C with sector

More information

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-JBG2 Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA AIR COMFORT AIR DIFFUSION CHILLED BEAMS IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA 2 Chilled beam IQ Star NOVA II Technical data CHILLED BEAM IQ STAR NOVA II The NOVA II chilled beam is an active chilled

More information

Fire/combustion gas damper EKO-JBL

Fire/combustion gas damper EKO-JBL Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed

More information

KTI Supply air valve. Product Facts. Product code example. Quick Selection

KTI Supply air valve. Product Facts. Product code example. Quick Selection KTI Supply air valve KTI is a supply air valve suitable for houses, apartments and offices. It has a wide air volume range between 5-100 l/s. The valve is quick and easy to install in the duct without

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

ROOFMASTER STEF ROOF FAN

ROOFMASTER STEF ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF...3 Performance Data...4 Performance Table...6 General description...8 Fan Chart-explanation and

More information

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of FIRE SAFETY Fire Valve in libraries of EI 60 (v e -o i) S EN 131-3+A1:10 EN 156:10 Certificate of Conformity 1488-CPD-02 82/W FUNCTION The fire valves are designed for buildings where in the event of a

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

KSOM Control exhaust valve

KSOM Control exhaust valve KSOM Control exhaust valve KSOM is ideal for rooms which require forced exhaust air flow. KSOM consists of exhaust valve, control motor and controller card, which are installed in the valve cone. KSOM

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

CTVK Supply air diffuser

CTVK Supply air diffuser CTVK Supply air diffuser The CTVK is a very quiet supply air diffuser designed for wall mounting. The diffuser is suitable for use in small premises, such as offices, houses and hotel rooms. The air discharged

More information

SECTION 1 Grooved Fittings

SECTION 1 Grooved Fittings Anvil offers two different sets of stainless steel fittings. The Gruvlok Series Fittings have full flow designs formed from type 304SS pipe. The Schedule 10 fittings are fabricated from segmentally welded

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

DVAX-ARS. Roof-mounted unit for mechanical smoke extract Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit

More information

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBG Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.

More information

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD) Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD) The DYRB is a quiet, ceiling-mounted supply air unit that consists of a nozzle diffuser, DYRH, and a plenum box, ATTD. The diffuser has adjustable

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Exhaust air diffuser HPKH + Plenum box ATTS

Exhaust air diffuser HPKH + Plenum box ATTS Exhaust air diffuser HPKH + Plenum box ATTS The HPKH is a quiet, ceiling-mounted exhaust air diffuser. The diffuser has an almost completely perforated diffuser plate. The slot height of the diffuser can

More information

IrisControlDamper. For Adjustment and Measuring of Airflow.

IrisControlDamper. For Adjustment and Measuring of Airflow. IrisControlDamper For Adjustment and Measuring of Airflow www.actionair.co.uk sales@actionair.co.uk Iris Control Damper (ICD) Quick, silent and efficient is the simple summary of the features of the Actionair

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE 83 PLASTIC TUBE FANS - ESPADA FEATURES mm to 315 mm diameter Air flow up to.35 m 3 /s Static pressures up to 58 Pa Plastic cased centrifugal fan Low noise levels Corrosion resistant design Easy electrical

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

Technical information

Technical information 6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

Systemair Fire Dampers

Systemair Fire Dampers Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION 95 METAL TUBE FANS - ROPERA EC FEATURES mm to 355 mm diameter Air flow up to.56 m 3 /s Static pressures up to 7 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection via

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE RECTANGULAR VAV DAPER ERVA TECHNICAL CATALOGUE Rectangular VAV damper ERVA - Technical catalogue 2 KEY FEATURES Variable airflow Constant airflow Real-time airflow measurement with FläktGroup compact controller

More information

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper Halton PTS Single-Blade Damper Shut-off, adjustment, balancing or control damper Casing leakage classification: EN 1751, Class C Casing and damper blade made of galvanised steel Tightness classification

More information

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high

More information

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air 5/9.2/EN/6 Volume Flow Limiter Type VFL for insertion into air ducting The art of handling air Contents Description 3 Dimensions 3 Nomenclature 4 Technical data 4 Acoustic data 4 Installation notes 5 Order

More information

table of contents PRODUCT SUMMARY 2

table of contents PRODUCT SUMMARY 2 P R O D U C T C A T A L O G introduction Aire Technologies, Inc. is proud to present our line of air management and life safety products for integration into your HVAC system design, fabrication, or installation.

More information

BRC

BRC ------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings

More information

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE FIRE SAFETY AIR ANAGEENT FIRE DAPERS FK120/FK90 FIRE DAPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND AINTENANCE ZU CLOSED AUF OPEN 2 FK120/FK90 Fire damper Instructions for installation, operation

More information

THE WORLD S FASTEST DUCTING

THE WORLD S FASTEST DUCTING NORDFAB DUCTING CATALOGUE Quick-Fit C l i p p e d D u c t i n g THE WORLD S FASTEST DUCTING & FLANGED DUCTWORK Nordfab QF Clipped and FL Flanged ducting QF clipped and FL flanged ducting offers a complete

More information

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several

More information

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance March 29 Iris Control Damper (ICD) NEW Iris Control Damper (ICD) For adjustment and measuring of airflow Features Quick and simple installation and maintenance Extended spigot connections 1% opening capacity

More information

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 48 /1200 in a variety of straight and reducing styles. Most standard fittings are cast of durable

More information

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,

More information

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable

More information

STAINLESS STEEL MILL SPOUTING

STAINLESS STEEL MILL SPOUTING STAINLESS STEEL MILL SPOUTING Most of our mild steel spouting can be manufactured in stainless steel if required ON-SITE POWDER COATING Digital Catalogue Version 2013 Update 1 Page 1 of 23 STRAIGHT PIPE

More information

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

Exhaust air diffuser EYMA-2 and air intake device DYMA-1 Exhaust air diffuser EYMA- and air intake device DYMA- Exhaust air diffuser EYMA- and air intake device DYMA- An air intake device supplying the premises with fresh air and an exhaust air diffuser discharging

More information

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD) Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD) The RPPA and ROPA are quiet, ceiling-mounted supply air units that consist of a supply air diffuser, RPPH or ROPH, and

More information

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA Wall diffuser SVQC / Supply air unit SVQC + ATVA SVQC is a quiet supply air diffuser intended for mounting on a wall. The device is particularly

More information

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable

More information

NORDFAB DUCTING CATALOGUE

NORDFAB DUCTING CATALOGUE NORDFAB DUCTING CATALOGUE C l i p p e d D u c t i n g THE WORLD S FASTEST DUCTING & FLANGED DUCTWORK Nordfab QF Clipped and FL Flanged ducting QF clipped and FL flanged ducting offers a complete range

More information

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Shut-off dampers. Type AKK. For contaminated air PD AKK 1 X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems

More information

Ventiduct nozzle ducts

Ventiduct nozzle ducts Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement

More information

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,

More information

CHILLED BEAM IQ STAR WEGA II

CHILLED BEAM IQ STAR WEGA II CHILLED BEAM IQ STAR WEGA II TECHNICAL CATALOGUE 2 IQ Star WEGA II Chilled beam - Technical catalogue CHILLED BEAM IQ STAR WEGA II The WEGA II chilled beam is an active chilled beam system for ventilation,

More information

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable

More information

NV series. Induction VAV air volume control terminals

NV series. Induction VAV air volume control terminals NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...

More information

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation ADRIATIC VF Climate beam Adriatic Adriatic is an enclosed climate beam with integrated

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information