SYRACUSE FIRE DEPARTMENT RFP SPECIFICATIONS FOR 3000 GALLON WATER TENDER

Size: px
Start display at page:

Download "SYRACUSE FIRE DEPARTMENT RFP SPECIFICATIONS FOR 3000 GALLON WATER TENDER"

Transcription

1 EXCEPTIONS Any bidder who is unable to meet any of the below specifications shall include with his/her bid, a description of the component of their apparatus that does not meet specification, along with a reason why the specification cannot be met. WHEELBASE The apparatus shall have a wheelbase not to exceed 205 inches CAB & CHASSIS The cab and chassis shall be manufactured by Kenworth, Peterbilt, International, Freightliner, or equivalent and shall have all necessary changes made to meet NFPA 1901 requirements for fire apparati. The apparatus shall have a GVWR of not less than 54,600 lbs. The cab and chassis shall include the following: Electric Door Locks LH/RH Keyless Ignition Single-piece Windshield Electric windshield wipers, minimum of 2-speed plus intermittent Electric windshield washers Glove box door with locking latch Turn signal switch with column mounted dimmer Floor mat Inside sun visor, LH/RH Door courtesy lights HEAT PROTECTION The exhaust after-treatment system shall be sufficiently shielded or wrapped to protect the underside of the chassis cab during active regeneration. Heat from regeneration shall not be detected by personnel seated inside the cab. AIR LINE, FUEL HOSE AND ELECTRICAL HARNESS AND CONNECTOR PROTECTION All air lines, fuel lines and electrical harnesses below the chassis frame rails shall be protected with a fire resistant sleeve. All air lines and connectors to air tank located between chassis steps shall be protected with a fire resistant sleeve. CABIN AIR EMBER GUARD The cabin air filter shall be protected by an ember guard with a maximum mesh opening of inches. FUEL TANK & EQUIPMENT The fuel tank shall have a capacity of not less than 50 US gallons.

2 CAB & EQUIPMENT The cab shall have a seating capacity of not less than two (2) personnel The cab shall have the following equipment installed: Cab heater with integral defrosters & air conditioning Adj. telescoping tilt steering column Dash mounted air cleaner restriction gauge Instrument package (speedo, tach, temp, oil press, voltmeter) Warning light for parking brake NFPA compliance kit (seat sensors, seatbelt switches, VDR harness) Seat belts colored to meet NFPA standards Radio AM/FM Self-cancelling turn signals LH & RH NFPA compliant grab handles Aerodynamic heated mirrors Electric window lifts AIR EQUIPMENT The air system shall have a Bendix AD series heated air dryer or equivalent. CHASSIS WARRANTY The chassis manufacturer s warranty shall be in effect and shall commence on the day of acceptance by the purchaser. BUMPER EXTENSION The front bumper shall be a 12 extended bumper or greater. All surfaces shall be polished aluminum or chrome for a neat appearance. The top surface shall be diamond plate. ENGINE The engine shall have a horsepower rating of not less than 330 Horsepower EXHAUST BRAKE An exhaust brake shall be installed on the chassis. This brake shall have a switch to turn it on or off within easy reach of the driver TRANSMISSION The transmission shall be an Allison 3000EVS 6-speed with with provisions for two (2) PTOs. FRONT AXLE & EQUIPMENT The front axle shall have a rating of not less than 14,600 lbs. REAR AXLE & EQUIPMENT The rear tandem axles shall have a rating of not less than 40,000 lbs.

3 TIRES The tires shall be bridgestone or equivalent WHEELS The front and rear outer wheels shall be polished aluminum The rear Inner Wheels shall be steel and shall be treated to prevent corrosion STAINLESS STEEL WHEEL COVERS The front and rear axle(s) shall have stainless steel lug nut covers. AIR HORNS The apparatus shall have an air horn installed that shall be controlled by a lanyard that is located within easy reach of the driver REAR MUD FLAPS Two (2) black hard rubber mudflaps shall be installed behind the rear wheels, one each side. NFPA COMPLIANCE The completed apparatus shall be in compliance with the latest published version of NFPA APPARATUS TOP SPEED The apparatus shall not exceed either 60 mph (85 km/hr) or the manufacturer s maximum fire service speed rating for the tires installed on the apparatus, whichever is lower. VEHICLE STABILITY The calculated center of gravity shall be no higher than 80% of the rear axle track width to conform to NFPA VDR DATA The completed apparatus shall have a VDR Data recorder installed. The following information shall be collected. Vehicle speed in mph Acceleration (from speedometer) mph/sec Deceleration (from speedometer) mph/sec Engine speed rpm Engine throttle position % of full throttle Anti-lock braking system event On/off Seat occupied status Occupied: Yes/No by position Seat belt status Buckled: Yes/No by position Master optical warning device switch On/off Time 24-hour clock Date Year/month/day

4 SEAT BELT INDICATORS Signs that read Occupants Must be Seated and Belted When Apparatus Is in Motion shall be visible from each seated position. Each seating position that is not intended to be used during transit shall be individually labeled as follows: WARNING: THIS SEAT IS NOT TO BE OCCUPIED WHILE VEHICLE IS IN MOTION. A seat belt warning system shall be provided. The warning system shall consist of an audible warning device that can be heard at all seating positions designed to be occupied while the vehicle is in motion and a visual display visible to the driver, showing the condition of each seating position. The warning shall be activated anytime the parking brake is released or the automatic transmission is not in park. The seat position display shall indicate conditions in accordance with Table The display indication shall be permitted to consist of lights, text, graphical indicators, digital displays, or other methods. TIRE PRESSURE MONITORING Each tire shall be equipped with a visual indicator located on the stem that indicates the tire pressure. JUMPER POSTS NFPA Complaint External Battery Jumper Posts, color coded with protective covers shall be installed on the apparatus. HELMET HOLDERS There shall be two (2) Zico UHH-1 helmet holder bracket(s) provided in the cab. The brackets shall provide quick access and secure storage of the helmet(s). The bracket location(s) shall be determined at time of final inspection. This item shall be priced separately as an option. TOW HOOKS No less than Two (2) rear tow hooks in the front, and two (2) in the rear shall be provided on the apparatus. These shall be fastened to the chassis frame rails.

5 FLUID DATA PLAQUE A fluid data plaque containing required information shall be provided based on the applicable components for this apparatus, meeting current NFPA 1901 Standards as follows: A. Engine oil B. Engine coolant C. Chassis transmission fluid D. Pump transmission lubrication fluid E. Pump primer fluid F. Drive axle(s) lubrication fluid G. Air conditioning refrigerant H. Air conditioning lubrication I. Power steering fluid J. Cab-tilt mechanism fluid K. Transfer case fluid L. Equipment rack fluid M. Air compressor system lubricant N. Generator system lubricant Location shall be in the driver's compartment of the chassis cab. OVERALL HEIGHT, LENGTH, GVW DATA PLAQUE The cab dash area shall have a highly visible plaque noting overall maximum height of vehicle, length and GVW of the finished apparatus. "NO RIDE" LABEL A label shall be located on the vehicle at the rear step areas, and at any cross walkways, if they exist. The label(s) shall warn personnel that riding in or on these areas while the vehicle is in motion is prohibited. SEATING LABEL A label shall be installed in cab to denote the exact number of passengers to be carried in cab. 500 GPM PUMP The pump shall be a Darley, model HM500, single-stage construction, PTO driven pump or equivalent, and shall comply with all applicable requirements of the latest standards for automotive fire apparatus of the National Fire Protection Association and shall have a rated capacity of 500 GPM at 150 PSI. COLOR CODED LABELS A set of color coded and function described labels shall be provided on the apparatus for the pump operator's controls, gated inlets, discharge outlets, drains, and pressure gauges (as applicable). The labels shall be a high quality material with a durable adhesive on the back.

6 PUMP PANEL LIGHT The pump panel shall have adequate illumination to be able to easily read all pump panel information for night time operations. PUMP SYSTEM 500 GPM PTO A power takeoff (PTO) driven centrifugal booster pump rated up to PSI, shall be provided. The pump shall be placed in gear from the chassis cab. The pump shift shall be clearly labeled. The pump gear ratio shall be selected by the builder of the pump for the application. The pump shall have a nickel alloy casing. A bronze, double hubbed impeller, mechanically and hydraulically balanced, shall be installed on a splined stainless steel shaft. The impeller shaft shall be supported by oil lubricated ball bearings. The pump gear case shall be silent running, with helically cut gears, fully supported by ball bearings, and shall have two (2) replaceable, bronze seal rings. PTO DRIVE The pump shall be driven by integral PTO. The PTO model and gear ratio shall be determined by the prime contractor's Engineering Department. A driveline properly balanced from the PTO to the pump shall be supplied and installed. PUMP SHIFT - PTO Pump and Roll One (1) PTO shall be installed to drive the fire pump. An electrically activated switch shall be installed in the cab to engage the fire pump. Safety interlocks shall be provided to ensure the pump drive system components are properly engaged to safely operate the pump during standard pumping and pump and roll applications. Pump shifting instructions shall be provided at the pump shifting location. PLUMBING SYSTEM The plumbing system shall consist of stainless steel hard piping, or flexible high pressure hose with stainless steel ends, as deemed necessary for the application. Upon completion, the entire system shall be fully pressure tested. The plumbing and valve arrangement shall be capable of delivering water to the pump at a minimum flow rate of 500 GPM while pumping at 150 psi pressure. All intakes shall be provided with suitable closers (valves or caps) capable of withstanding 500 PSI. All discharges and intakes shall terminate with chrome NST adapters, with chrome caps and chains, unless detailed otherwise in these specifications. NOTE: WITH THE EXCEPTION OF THE INTAKE RELIEF VALVE, ALL VALVES ADDED BY APPARATUS MANUFACTURER SHALL BE AKRON

7 MECHANICAL SEAL The pump shall be furnished with a Darley maintenance free mechanical seal. The mechanical seal shall be a non-contacting, non-wearing dual seal design. Seal shall be a Silicon Carbide Mechanical seals with welded springs. The stationary face of mechanical seals shall be made from Silicon Carbide, and be extremely hard and of a heat dissipative material, which resists wear and dry running damage much better than conventional Ni-resist and Tungsten Carbide materials PRESSURE RELIEF VALVE-NONE Pressure controlled by electronic governor. INTAKE RELIEF VALVE One (1) bronze intake relief valve shall be provided and mounted on the suction side of the pump, adjustable from psi, on the valve itself. The valve shall be factory preset at approximately 125 psi. The system does not include an on/off control. ELECTRIC PRIMER (FLUIDLESS) The fire pump priming system shall consist of one (1) 12V positive displacement type rotary vane primer of a fluidless design. A single control shall be located on the pump operator's panel. The primer shall not require a lubrication tank. The priming pump shall be constructed of heat treated aluminum and hard coat anodized. MASTER DRAIN One (1) rotary style master drain shall be installed on the lower portion of the side control panel. It shall be of brass construction and use a rotary screw mechanism against a rubber sealing surface. Each port shall be isolated. An "open and closed" label with arrows indicating direction shall be installed. 1/4 TURN DRAINS Each gated 1-1/2" or larger inlet and discharge shall have a quarter turn drain valve installed. The drain valves shall be located along the bottom on each pump panel. Inlets & discharges shall be plumbed to each drain at the lowest point. Each drain shall be plumbed with low-pressure hose to drain below bottom of the apparatus and be directed away from the pump operator. Each drain valve shall have a T-handle control with a recess in the "T" for a color-coded function label. PUMP PANEL ID PLATE An identification plate, prepared by the fire pump manufacturer, shall be installed on the pump operator control panel to identify the fire pump serial number, model number, and performance.

8 WARNING - PUMP OPERATOR A warning plate shall be installed on the pump operator's panel which states the following: WARNING: Death or serious injury might occur if proper operating procedures are not followed, or similar. INLETS/OUTLETS The apparatus shall have no less than the following: One (1) 4" suction steamer inlet with male NH threads shall be provided on the apparatus. The inlet shall have a removable screen. One (1) 2-1/2" brass suction valve shall be installed on the apparatus. The control handle shall be the quarter turn ball type, of the fixed pivot design, and located along side the suction valve. The suction shall terminate with a 2-1/2" female NST chrome inlet swivel, a chrome male plug, chain, and a brass inlet strainer. Two (2) 2-1/2" discharge outlets with 2-1/2" pipe and valve and chrome NST threads shall be installed. The valve shall be a quarter turn ball type, self locking, fixed pivot design and shall be operated with a lever control from the operator's panel. The valve shall be a bronze valve with a high polished stainless steel ball. The valve shall have a chrome cap and a stainless steel retaining chain. A gauge, as described elsewhere, shall be installed on the operator's control panel adjacent to each control. ANY ADDITIONAL INLETS/OUTLETS SHALL BE CONSIDERED AS VALUE ADDED ITEMS. TANK TO PUMP LINE (ELECTRIC) One (1) 4.00 tank to pump line shall be provided for connection between a water tank and the fire pump. The valve shall be a 4.00" butterfly type. The valve shall be controlled from the pump operator panel using an electric open/closed, twoposition toggle switch with a green indicator light for the open position, and an amber indicator light for the closed position. The Tank to Pump Plumbing System and Valve Arrangement Shall be Capable of delivering water to the fire pump at a minimum flow rate of 800 GPM, while pumping at 150-psi pressure. 2" TANK FILL One (1) 2" pump to tank fill line shall be installed with a 2" inline bronze valve. The valve shall be manually controlled and properly labeled. TWO (2) 1 ¾ CROSSLAYS Two (2) 1-3/4" crosslays shall be installed on the apparatus. The crosslays shall each have capacity for 200 ft. of 1-3/4" double jacket fire hose. Two (2) 2-1/2" liquid filled gauges, each with a stainless steel bezel shall be provided, one for each discharge. The gauges shall be located on the pump operator's panel near the respective discharge control.

9 CROSSLAY HOSE RETENTION The crosslays shall have a hose retention system that meets NFPA requirements. BOOSTER REEL One (1) HANNAY painted steel booster reel with electric rewind shall be supplied and mounted on the apparatus within easy reach from a standing position on the ground. The reel shall be capable of carrying 150 feet of 1-inch booster hose. The reel shall have 1 Female NPT inlets with 90 degree ball bearing swivel joints. The reel shall have a 1 Male NST outlet. The reel shall have one (1) booster rewind button located next to it. There shall be an auxiliary gear-driven crank rewind that shall be easily accessible. 1 BOOSTER REEL HOSE The booster reel shall be supplied with 150 of 1 lightweight non-collapsible hose. AKRON FORESTRY MONITOR An Akron forestry wildland electric monitor model 3462 Forestry Monitor shall be installed in the front bumper. The monitor shall be plumbed with 2 ½ Class1 high pressure hose from the pump. Drain pit cocks shall be furnished in the supply line to allow for draining the pipe for cold weather operations. This item shall be priced separately as a complete installation, and with the manufacturer providing the plumbing to the front bumper only. This shall also be priced with the quick disconnect option.. MONITOR NOZZLE An Akron flow adjustable electric fog nozzle shall be supplied with the monitor. GROUND SWEEP NOZZLES Two (2) ¾ fixed ground sweep nozzles, plumbed to the on-board foam system, shall be provided and installed beneath the front bumper of the apparatus. One (1) nozzle shall be provided on the driver s side end of the front bumper and one (1) nozzle shall be provided on the passenger s side of the front bumper. The nozzles shall be plumbed with stainless steel piping or flexible high pressure hose. The nozzles shall be controlled from individual switches provided in the cab center console. The nozzles shall be capable of being put into operation during pump and roll operations. Nozzle valves and plumbing shall be enclosed or protected. LED WATER LEVEL GAUGE The apparatus shall have a minimum of three (3) LED water level gauges. One shall be installed in the cab within view of the driver, one shall be installed on the pump control panel, and a large LED display shall be installed on the rear of the tank.

10 INDIVIDUAL PRESSURE GAUGES Individual pressure gauges shall be provided, one for each discharge. Gauges shall read from -30" Hg. to 600 psi and shall be accurate to within 1%. The gauges shall be located on the pump operator's panel near the respective discharge control. MASTER PRESSURE GAUGE One master pressure gauge shall be provided, reading from -30" Hg. to 600 psi. It shall be accurate to within 1%. The gauge shall be located on the pump operator's panel. MASTER INTAKE GAUGE One (1) master intake gauge shall be provided, reading from -30" Hg. to 600 psi. It shall be accurate to within 1%. The gauge shall be located on the pump operator's panel. PRESSURE GOVERNOR and ENGINE MONITORING DISPLAY A pressure governor and monitoring display kit shall be installed. The following continuous displays shall be provided: Engine RPM Check engine and stop engine warning LEDs Oil pressure Engine coolant temperature Transmission Temperature Battery voltage Pressure and RPM operating mode LEDs Pressure / RPM setting Throttle ready LED. It shall monitor inputs and support audible and visual warning alarms for the following conditions: High Battery Voltage Low Battery Voltage (Engine Off) Low Battery Voltage (Engine Running) High Transmission Temperature Low Engine Oil Pressure High Engine Coolant Temperature Low water supply No Engine Response (visual alarm only). The governor shall operate in two control modes, pressure and RPM. No discharge pressure or engine RPM variation shall occur when switching between modes. A throttle ready LED shall light when the interlock signal is recognized. The governor shall start in pressure mode and set the engine RPM to idle. In pressure mode the governor shall automatically regulate the discharge pressure at the level set by the operator. In RPM mode the governor shall maintain the engine RPM at the level set by the operator except in the event of a discharge

11 pressure increase. The governor shall limit a discharge pressure increase in RPM mode to a maximum of 30 psi. The pressure governor and display shall be programmed to interface with the chassis engine. FOAM SYSTEM The apparatus shall be equipped with Foam Pro 1600 series single agent foam system or equivalent. An installation and operation manual shall be provided for the unit, along with a one-year limited warranty by the manufacturer. The system must be installed and calibrated by a Certified FoamPro Dealer, or a certified installer of an equivalent system. The system design shall have passed environmental testing which simulates heavy use on off-road mobile apparatus. Testing shall have been conducted in accordance to SAE standards. CLASS A ONLY The foam system will only operate Class A foam GALLON POLY TANK Tank shall have a capacity of 3000 gallons and shall carry a lifetime warranty from the manufacturer. The tank manufacturer shall furnish notice that indicates proof of warranty. The purpose of the notice is to inform department personnel who work, store, stock, or use the tank that the unit is under warranty. CONSTRUCTION The tank shall be constructed using polypropylene with a minimum thickness of ½. This material shall be a high impact co-polymer (HIC) non-corrosive stress relieved thermoplastic, UV stabilized for maximum protection. All joints and seams shall be nitrogen welded and tested for maximum strength and integrity. Tank shall be equipped with a see-thru water level indicator at the rear of the tank. All tank baffling shall meet the latest NFPA standard as well as any other applicable standard at the time of manufacture FILL TOWER The tank shall have a vent/ fill tower. The tower shall have a removable polypropylene screen and a polypropylene hinged type cover. Inside the fill tower, approx 4 down from the top shall be fastened a combination vent overflow pipe. The vent overflow shall be a minimum of schedule 40 polypropylene pipe with a minimum I.D. of 4 that is designed to run through the tank, and shall be piped behind the rear wheels. SUMP There shall be one (1) sump standard per tank. The sump shall be constructed of polypropylene. The sump shall have a 4 NPT threaded outlet on the bottom for a drain plug. This shall be used as a combination cleanout and drain. All tanks shall have an anti-swirl plate located approx 2 above the sump.

12 TANK OUTLETS The tank shall have the appropriate amount of 10 Newton Dump Valve flanges as specified in this document. Appropriate tank openings will be provided for tank suction and tank fills. All tank fill couplings shall be backed with flow deflectors to break up the stream of water entering the tank, and be capable of withstanding sustained fill rates of up to 1000 gpm. All outlets and inlets must meet all NFPA 1901 guidelines in effect at the time of manufacture. CLEAR WATER LEVEL GAUGE The rear wall of the tank shall have a standard built-in liquid level sight gauge. TANK MOUNTING Tank must be mounted in accordance with the most current DOT, NFPA and any other applicable standard. The tank shall be mounted in the safest way possible to help prevent rollover. HOSEBED Tank shall have a minimum 9 high hose bed around three sides of the top of the tank. PAINT Tank shall be painted to match cab. FOAM CELL The apparatus shall have a 30 gallon foam tank. HOSEBED RETENTION The apparatus shall be equipped with an NFPA compliant hose retention system. DUMP VALVE The apparatus shall have one (1) 10 manual dump valve located in the center of the rear of the tank as low as possible to allow for maximum drain. The dump valve and chute shall have the ability to dump straight off of the back of the vehicle, or to either side. 2 ½ REAR TANK FILL (LEFT SIDE) One (1) 2 ½ direct tank fill will be located at the rear of the tank, on the left side of the dump valve. The valve shall be a swing out valve with a 15 degree turndown with a chrome swivel and plug. 2 ½ REAR TANK FILL (RIGHT SIDE) One (1) 2 ½ direct tank fill will be located at the rear of the tank, on the right side of the dump valve. The valve shall be a swing out valve with a 15 degree turndown with a chrome swivel and plug.

13 COMPARTMENTATION FRONT OF AXLE COMPARTMENTS COMPARTMENT D1: One (1) compartment shall be supplied on the driver s side of the truck in front of the tandem axle. This compartment shall have a volume of not less than 21,000 cubic inches. The compartment shall be constructed from diamondplate aluminum and shall be of sweep out design. COMPARTMENT P1: One (1) compartment shall be supplied on the passenger s side of the truck in front of the tandem axle. This compartment shall have a volume of not less than 21,000 cubic inches. The compartment shall be constructed from diamondplate aluminum and shall be of sweep out design. REAR OF AXLE COMPARTMENTS COMPARTMENT D2: One (1) compartment shall be supplied on the driver s side of the truck behind the tandem axle. This compartment shall have a volume of not less than 11,500 cubic inches. The compartment shall be constructed from diamondplate aluminum and shall be of sweep out design. COMPARTMENT P2: One (1) compartment shall be supplied on the passenger s side of the truck behind the tandem axle. This compartment shall have a volume of not less than 11,500 cubic inches. The compartment shall be constructed from diamondplate aluminum and shall be of sweep out design. All compartments shall be supported by a steel frame and attached to the truck frame with grade 8 bolts. COMPARTMENT DOORS All compartment doors shall be Roll-Up style doors of appropriate size. The securing method will be full width lift bar to be operated with one hand, even with heavy gloves. COMPARTMENT LIGHTING Each compartment shall contain one (1) full length LED strip light. Strip lighting shall provide uniform light dispersion throughout the compartment even when shelves are installed. The compartment strip lighting shall be automatically activated whenever a compartment door is opened.

14 COMPARTMENT FLOOR MATS All enclosed side body compartments shall have floor mats installed in them, custom cut to fit the compartment floors. The floor mats shall be easily removable to allow the compartment to be cleaned. The floor mats shall be designed to provide ventilation to the equipment stored in the compartment, and to protect the stored equipment from direct contact with the metal compartment floor surfaces. HOSEBED COMPARTMENTS There shall be compartmentation built in to the hosebed area that shall run approximately the length of the passenger s side of the hosebed. These boxes shall be 12 tall and 36 deep. The doors and compartments shall be made of diamond plate aluminum. The doors shall have latching handles and when open shall be supported by a gas strut. The compartments shall be built to prevent moisture from entering when closed. Each compartment shall have an LED light that is activated when its door is open. This compartmentation may be divided up into multiple boxes if necessary for engineering purposes. A description of the dimensions of these compartments shall be included with each bidder s proposal. VENTS Each compartment shall have one (1) louvered vent that shall provided proper ventilation and prevent water from entering the compartment. SCBA WHEEL WELL STORAGE Four (4) SCBA bottle compartments, each with a locking door, shall be mounted within the rear fender areas, (2) each side. Each compartment shall Measure no less than 8 across x deep. DROP TANK STORAGE The apparatus shall have an area designated and designed to hold a Port-atank with a capacity of no less than the capacity of the tank of the apparatus. HARD SUCTION STORAGE There shall be a storage area built in to the apparatus to hold two (2) 10 sections of 4 hard suction hose. TAILBOARD The rear tailboard shall be built of a material which is suitable as a walking surface. ACCESS LADDER There shall be an access ladder to access the top of the tank. Folding steps may be substituted for a ladder.

15 12 VOLT ELECTRICAL SYSTEM The truck shall have a 12-Volt electrical system. All wiring will be run in convoluted high temperature plastic loom. Wiring shall be color and function coded and will be of adequate size to handle the assigned load. All solenoids, relays, and terminal blocks will be located in an easily accessible area. All circuits provided shall have properly rated low voltage over current protective devices. All electrical will be accordance with modern automotive wiring standards. All under side terminal junctions shall be fully enclosed in sealed plastic weather proof boxes. Electromagnetic interference suppression shall be provided as required to satisfy the radiation limits specified in SAE J551/1. ALTERNATOR PERFORMANCE TEST AT FULL LOAD The total continuous electrical load shall be applied with the chassis engine running up to the engine manufacturer s governed speed. The test duration shall be a minimum of two (2) hours. The activation of the electrical system load management system shall be permitted during this test. The activation of an alarm due to excessive chassis battery discharge, as detected by the system required by NFPA (current edition), or an electrical system voltage of less than 11.8 VDC for a 12 VDC nominal system, for more than 120 seconds, shall be considered a failure of this test. Documentation shall be provided demonstrating a completion of this test. MASTER BATTERY SWITCH A master battery on/off switch with shall be provided in the cab, near the driver s door. A green light indicating that the battery is on shall be visible from the driver s position. BACK-UP ALARM One (1) Back up Alarm shall be provided and installed at the rear of the unit. It shall be wired to activate when the transmission is placed in reverse. LOW VOLTAGE ALARM A low voltage alarm system shall be supplied and installed with an audio and visual warning indicator located in the cab. LOAD MANAGEMENT SYSTEM A load management system shall be installed in the apparatus. ADDITIONAL ANTENNA BASES Two (2) additional antenna bases shall be located on the roof of the chassis of the apparatus. These bases shall each have a coaxial cable ran to a location in the cab of the purchasing department s choosing.

16 UNDERBODY/CAB GROUND LIGHTS No less than four (4) 4 clear ground LED illumination lights, with outward facing angle brackets shall be provided and installed. The lights shall activate with the parking brake or when the transmission is placed in "neutral" or park. LICENSE PLATE LIGHT A license plate bracket with light shall be provided and installed on the rear of the body. It shall be wired to come on with the headlights. DO NOT MOVE APPARATUS A warning system shall be installed in the apparatus to inform the driver of conditions that could create a possible hazardous should the vehicle be moved. The warning shall consist of no less than a red light that is easily visible to the driver. A label that says Do Not Move Apparatus When Light is on or similar wording shall be placed adjacent to the light. In addition, accessories such as a ladder rack (or similar storage rack), any extendable light or tower or a telescoping deck gun device shall also be connected to this ajar circuit, to activate the light when any of these items are not properly stowed, and the parking brake is not engaged. CONSOLE All controls, warnings, and indicators to which the operator should have access or sight, shall be organized to create an efficient and ergonomic layout. The console area of the vehicle shall have no less than three (3) spare circuits, up to 30A each, ran to the area for additional equipment and terminated in a manner so as to render them safe should they not be used. The purchaser may elect to have these circuits to be connected directly to the battery, or powered with the battery switch. NFPA LIGHTING PACKAGE LIGHTBAR One (1) WHELEN LED lightbar shall be mounted on the apparatus. The LED colors and lens colors shall be selected by the purchaser. WARNING LIGHTS, UPPER ZONE The vehicle shall have an NFPA compliant warning light package. All warning lights shall be Whelen LED lights. All lights shall be controlled by a rocker switch on the console and by the emergency master switch. PERIMETER LIGHTS The vehicle shall have an NFPA compliant warning light package. All warning lights shall be Whelen LED lights. All lights shall be controlled by a rocker switch on the console and by the emergency master switch. NOTE: All LEDs shall be red and all lenses shall be clear.

17 REAR BEACONS Two (2) Whelen model L31H Super LED beacons shall be provided and installed on the upper rear corners of the tank. Both beacons shall be controlled by a switch on the console, and by the emergency master switch. The color of the beacons shall be: Driver s side shall be red Officer s side shall be Amber SIREN One (1) siren controller shall be installed in the cab within easy reach of the driver. It shall have the following options: Hard Wired Microphone Public Address Air Horn Hands Free Operation 100 WATT SPEAKER One (1) cast aluminum speaker rated at no less than 100 watts shall be flush mounted in the front bumper. DOT LIGHTING Exterior vehicle lighting shall meet DOT regulations. All DOT lighting shall be LED with the exception of the headlights. WHELEN TRAFFIC ADVISOR A traffic advisor light shall be installed on the rear of the apparatus. The control head shall be mounted inside the chassis cab and be within reach of the driver. The light shall have the following functions: left right inside to outside flash THIS ITEM SHALL BE PRICED SEPARATELY AS AN OPTION.

18 TELESCOPIC LED FLOODLIGHTS Two LED model side mount push up telescopic lights shall be installed. The light poles shall be anodized aluminum and have a knurled twist lock mechanism to secure the extension pole in position. The extension poles shall rotate 360 degrees. The outer poles shall be a grooved aluminum extrusion and qualify as an NFPA compliant handrail. The pole mounting brackets shall have a 3 1/2" offset. Wiring shall extend from the pole bottoms with a 4' retractable cord. The lampheads ultra-bright white LEDs. They shall operate at 12 volt DC, and generate a minimum of 14,000 lumens. The lampheads angle of elevation shall be adjustable at a pivot in the mounting arms and the position locked with a round knurled locking knob. The lampheads shall incorporate heat-dissipating fins. The lampheads and mounting arms shall be powder coated white. The floodlights shall be for fire service use. One light shall be located on each side of the vehicle body. THIS ITEM SHALL BE PRICED SEPARATELY AS AN OPTION SCENE LIGHTS Six (6) WHELEN halogen scene lights shall be mounted on the tank, in CAST aluminum bezels. The lights shall be mounted in the following locations: Two (2) Drivers side, one (1) each corner Two (2) Passengers side, (1) each corner Two (2) Rear, (1) each corner All six (6) lights shall be controlled by a rocker switch within easy reach of the driver. LIGHT TOWER A Shadow-RT, manufactured by Command Light, part number SL415-RT-LED, light tower shall be provided and installed on the apparatus. The light tower and its controls shall be installed in a location according to instructions given by the customer and the requirements of the light tower manufacturer. The light tower shall extend 49-1/2" above the mounting surface and shall extend to full upright position in less than 15 seconds. The overall size of nested light tower shall be 48" long x 30" wide x 8-1/2" high and weigh approximately 75 pounds. THIS ITEM SHALL BE PRICED SEPARATELY AS AN OPTION. LIGHT TOWER CONSTRUCTION AND DESIGN The Command Light assembly shall be of aluminum construction, with stainless steel shafts and bronze bushings for long life and low maintenance. The electrically controlled unit shall not require usage of the vehicle's air supply for operation, thereby eliminating the chance for air leaks in the vehicle braking system. Hydraulic or pneumatic type floodlights are not acceptable alternatives to the specified all electric light tower. The light tower shall be tested to in wind conditions of 90 mph (150 kph) minimum. Other type floodlights that have not been tested to these conditions are not acceptable.

19 LIGHT TOWER ELECTRICAL SYSTEM The light tower shall be a single-stage device capable of 355 degree rotation. The light shall be elevated by an electric linear actuators, the actuator shall adjust the light bank angle from 0 to 110 degrees. The tower base shall have a light that illuminates the envelope of motion during any movement of the light tower mast as required by NFPA1901. LIGHT TOWER CONTROLS The light tower shall be controlled with a hand-held 6 foot umbilical line remote control. The storage station for the remote control unit shall be equipped with a button to activate the "Auto-Park" automatic nesting feature. The controls on the remote box shall be: Two (2) switches for each 2 light bank One (1) switch for elevating /retracting the arm One (1) switch for rotation of the light bank One (1) switch to engage Auto-Park One (1) indicator light to indicate when light bank is out of roof nest position. One (1) indicator light to indicate when light bank is rotated to proper nest position. LIGHT TOWER FLOODLIGHTS The Command Light shall be equipped with the following bank of floodlights: Floodlight manufacturer: Whelen Engineering Number of lamp heads: Four (4) Pioneer Plus LED Voltage: 12 volt Watts of each lamp head: 150 watt Total watts of light tower: 600 watts Amperage per lamp head: 12.5 amps Total amperage of light tower: 50 amps Total Lumens of light tower: 45,000 lumens Configuration: The light heads shall be mounted with two (2) on each side of the light tower, giving two (2) vertical lines of two (2) when the lights are in the upright position. KUSSMAUL BATTERY CHARGER Kussmaul model # S-KIT, Auto Charge 1000 battery charger shall be wired to the 12 volt battery system. The charger unit shall be mounted in a clean dry area and will be accessible for service and/or maintenance. AUTO EJECT RECEPTACLE Kussmaul model 20 amp "auto-eject" shore power receptacle shall be provided on the apparatus. The shore power plug shall be "ejected" when the chassis's engine starter is engaged. The receptacle shall be wired to any 120 volt A/C equipment that requires shore power. An aluminum enclosure shall be provided with the receptacle for protection from road dirt and damage. The location shall be on the left side on the exterior of the vehicle.

20 AIR INLET W/DISCONNECT A Kussmaul Air Eject HP shall be supplied and installed on the apparatus. STRIPING A White reflective stripe no less than 6 wide shall be applied around the perimeter of the truck. NFPA Compliant reflective material shall be affixed to the inside of each hinged door. CHEVRON STRIPING At least 50% of the rear of the unit shall be covered with alternating 6" stripes of colors that meet NFPA requirement in an inverted Chevron pattern. Preferred colors are red and fluorescent green-yellow. LETTERING Faux gold leaf lettering shall be applied to each passenger door of the fire apparatus to match existing department apparatus. An allowance shall be included for up to fifty (50) letters. An allowance shall be included to provide and install up to fifty (50) reflective letters up to 12 in height. FOLDING TANK One (1) collapsible frame Fol-Da-Tank shall be supplied. It shall have a 17 oz. HPR High Performance Rubber liner that shall be yellow in color. Grab handles shall be placed on the side wall of the liner to help the firefighter pick up the liner when folding. The tank shall have a capacity of not less than the capacity of the tank of the apparatus. SUCTION HOSE Two (2) sections of 4 X 10 flexible, see thru hard suction hoses shall be furnished. THIS ITEM SHALL BE PRICED SEPARATELY AS AN OPTION. BARREL STRAINER One (1) KOCHEK BS40, 4 aluminum barrel strainer or equivalent shall be provided. THIS ITEM SHALL BE PRICED SEPARATELY AS AN OPTION. THE FOLLOWING LOOSE EQUIPMENT SHALL BE SUPPLIED WITH THE FINISHED APPARATUS: GROUND LADDERS The following fire service ground ladders shall be furnished and installed on the completed apparatus: One (1) 24ft. two section aluminum extension ladder One (1) 14ft. single section aluminum roof ladder with folding roof hooks One (1) 10ft. folding aluminum attic ladder THESE ITEMS SHALL BE PRICED SEPARATELY AS AN OPTION.

21 LADDER BRACKETS Racks shall be installed on the apparatus to accommodate the above listed ladders. PURCHASER RESPONSIBILITY It shall be the responsibility of the purchaser to supply all NFPA 1901 equipment not listed in this specification before the apparatus is placed in service. INSPECTION TRIP The bidder s price shall include a final inspection trip for two (2) personnel from the purchasing fire department. The trip shall include: round-trip airline from SLC Airport, ground transportation, and hotel accommodations for two (2) nights. DELIVERY Delivery of the apparatus from the factory to the purchasing department s home location shall be included in the price of the vehicle. The vehicle shall be delivered under it s own power. WARRANTY PROVISIONS ONE (1) YEAR APPARATUS WARRANTY All materials and workmanship herein specified, including all equipment furnished, shall be guaranteed for a period of one (1) year after the acceptance date of the apparatus, unless otherwise noted, with the exception of any normal maintenance services or adjustments which shall be required. Under this warranty, the apparatus manufacturer shall be responsible for the costs of repairs to the apparatus that have been caused by defective workmanship or materials during this period. This warranty shall not apply to the following: - Any component parts or trade accessories such as chassis, engines, tires, pumps, valves, signaling devices, batteries, electric lights, bulbs, alternators, and all other installed equipment and accessories, in as much as they are usually warranted separately by their respective manufacturers, or are subject to normal wear and tear. - Failures resulting from the apparatus being operated in a manner or for a purpose not recommended by the apparatus manufacturer. - Loss of time or use of the apparatus, inconvenience or other incidental expenses. - Any apparatus which has been repaired or altered outside of the apparatus manufacturer's factory in any way that affects its stability, or which has been subject to misuse, negligence, or accident.

1500 GPM CAFS WASP Sheldon Fire & Rescue Houston, TX ESD 60 ESD 60. Darley September 25, 2015 PART NO DESCRIPTION QTY

1500 GPM CAFS WASP Sheldon Fire & Rescue Houston, TX ESD 60 ESD 60. Darley September 25, 2015 PART NO DESCRIPTION QTY 1500 GPM CAFS WASP Sheldon Fire & Rescue Houston, TX 77044 ESD 60 ESD 60 Darley 3248 September 25, 2015 PART NO DESCRIPTION QTY 00-00-4100 Cover Page 1 00-00-6000 General Info 1 00-01-0000 ---ADMINISTRATION

More information

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES P a ge 1 FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES *Effecitive dates for Bid 15-11-0116 are: February 1, 2015 through March 31, 2016. SPECIFICATION

More information

PART NO DESCRIPTION QTY

PART NO DESCRIPTION QTY Stock Unit Fouts Bros. Fire Equipment Production # FBFE11437 1-800-948-5045 sales@foutsfire.com Quote No: 15107-0002 TANKER: FBFE3000 3000 Gallon Super Tanker 01/28/2013 Page 1 == 3000 Gallon Super Tanker

More information

QUOTE For a 2017 Fire Department Conventional Truck Chassis-Water Tender With PTO Pump

QUOTE For a 2017 Fire Department Conventional Truck Chassis-Water Tender With PTO Pump Town of Wascott PO Box 159,Wascott, WI 54890 Phone: 715/466-4252 Email: wascott@centurytel.net QUOTE For a 2017 Fire Department Conventional Truck Chassis-Water Tender With PTO Pump Note: Bidders must

More information

1500 GPM Vision WASP W. S. Darley & Co

1500 GPM Vision WASP W. S. Darley & Co QUOTATION 1500 GPM Vision WASP W. S. Darley & Co Darley 3204 Neal E. Brooks Gilman Fire Protection District National Sales Manager Gilman, IL 60938 Itasca, IL 60143 815-383-7694 815-739-9822 Chief Steve

More information

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES SPECIFICATION #09 75 REAR MOUNTED AERIAL APPARATUS ALL ITEMS FACTORY INSTALLED UNLESS OTHERWISE INDICATED

More information

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank FIRE PUMP DANKO XL SKID UNIT UPF Defender Poly Tank A Waterous 2515LE pump shall be provided and bolted directly to the specified engine and capable of the following performance: Max Pressure - 75 GPM

More information

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank FIRE PUMP A Waterous 2515-LE pump shall be provided and bolted directly to the specified engine and capable of the following performance: Max Pressure

More information

Darley UHP-HV Diesel Specification 1

Darley UHP-HV Diesel Specification 1 Darley UHP-HV Diesel Specification 1 This dual pump is designed for either a powerhead type unit or a full module. The module provides a self-contained diesel powered slide-in type ultra high pressure

More information

Commercial Traditional Engine 1250 GPM Side Mount Pump Rating 1200 Gallon - Stainless Body

Commercial Traditional Engine 1250 GPM Side Mount Pump Rating 1200 Gallon - Stainless Body 8/3/2011 Chassis International 4400 Chrome Bumper 35,000# GVWR 12K front 23K rear ABS / ATC / ESC Painted Wheels 330 Horsepower / 3000EVS 5-speed 220 Amp Alternator 50 Gallon Fuel Tank 2-door conventional

More information

GALLATIN PUBLIC UTILITIES

GALLATIN PUBLIC UTILITIES GALLATIN PUBLIC UTILITIES Bid Proposal Item: Single Axle Dump Truck Bid Date: Company Address: Phone Number: Manufacturer: Bid Information (1) Prices F.O.B., 249 Hancock Street, Gallatin, Tennessee 37066.

More information

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES SPECIFICATION #23 TRACTOR-DRAWN AERIAL APPARATUS ALL ITEMS FACTORY INSTALLED UNLESS OTHERWISE INDICATED

More information

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES SPECIFICATION #09 75 REAR MOUNTED AERIAL APPARATUS ALL ITEMS FACTORY INSTALLED UNLESS OTHERWISE INDICATED

More information

Albemarle County Virginia Brush Fire Truck Specification

Albemarle County Virginia Brush Fire Truck Specification Albemarle County Virginia Brush Fire Truck Specification Purpose: This specification is intended to be used for the procurement of Brush Fire Suppression Apparatus for the Fire Departments & Companies

More information

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES SPECIFICATION #09 75 REAR MOUNTED AERIAL APPARATUS ALL ITEMS FACTORY INSTALLED UNLESS OTHERWISE INDICATED

More information

ACCEPT ONLY THE BEST

ACCEPT ONLY THE BEST ACCEPT ONLY THE BEST Cab & Chassis The truck shall be supplied by the customer. CET Fire Truck Glider kit #7 Revised January 10 th 2018 The glider kit is made for dual rear wheels truck with a «back-of-cab-to

More information

The bidder shall furnish a complete set of Operator, Service, and Parts Manuals with each body sold.

The bidder shall furnish a complete set of Operator, Service, and Parts Manuals with each body sold. 2013 Model or current production year 34,000 G.V.W.R. Cab and Chassis INTENT: These specifications describe a Dump Truck. GENERAL TERMS: All equipment furnished under this contract shall be new, unused,

More information

145 HP, FRONT WHEEL ASSIST TRACTOR 3/17/15 Page 1. Mountrail County Road and Bridge SPECIFICATIONS FOR

145 HP, FRONT WHEEL ASSIST TRACTOR 3/17/15 Page 1. Mountrail County Road and Bridge SPECIFICATIONS FOR Page 1 Mountrail County Road and Bridge S FOR Bidder's Instructions: Indicate compliance to the specifications on the YES/NO line by each specification. Indicate any deviations from the specifications

More information

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial MODEL NUMBER DC1911-3000 AT/AL/MC Draft Commander 3000 Specifications MODEL NUMBER DC1911-3000

More information

NELSON COUNTY FISCAL COURT

NELSON COUNTY FISCAL COURT NELSON COUNTY FISCAL COURT Specifications/Bid Forms FOR 25 CUBIC YARD REAR PACKER,REAR EJECTION, GARBAGE TRUCK DATE: 08/2017 ADVERTISEMENT FOR BIDS The Nelson County Fiscal Court will accept sealed bids

More information

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G Scope and General Design Requirements A firefighting system shall be provided for offensively attacking a fire.

More information

RAC EXPORT TRADING Germany Tel

RAC EXPORT TRADING Germany   Tel Technical Specification Kenworth 963S oilfield truck, new GAWR RATINGS Front Axle Weight Rating 40.000 Lb. 18.140 kg Rear Axle Weight Rating 150.000 Lb 68.030 kg Gross Vehicle Weight Rating 190.000 Lb.

More information

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF CONSERVATION & NATURAL RESOURCES BUREAU OF FORESTRY DIVISION OF FOREST FIRE PROTECTION

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF CONSERVATION & NATURAL RESOURCES BUREAU OF FORESTRY DIVISION OF FOREST FIRE PROTECTION COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF CONSERVATION & NATURAL RESOURCES BUREAU OF FORESTRY DIVISION OF FOREST FIRE PROTECTION Specifications for 500-Gallon Wildland Fire Flatbed Unit *Unless indicated

More information

Mantis Rerailer General Specifications

Mantis Rerailer General Specifications 2008 General Specifications 1. Typical Operating Parameters 2. General 1.1 Operating temperatures will typically be between 20 F (7 C) to 110 F (43 C). 1.2 Relative humidity ranges between 20% and 100%.

More information

32 quarts Transmission Allison HT 740 Automatic Fluid

32 quarts Transmission Allison HT 740 Automatic Fluid BOOK: Blue Book I SECTION: E-One Engine (SGT) Page 1 of 6 E-ONE CYCLONE TABLE OF CONTENTS SPECIFICATIONS... 2 DAILY CHECKS... 2 SAFETY CHECKS... 3 START ENGINE... 3 STOP ENGINE... 3 EMERGENCY SHUTDOWN

More information

Standard features. Standard features of the Unimog U500 NA 2005 model

Standard features. Standard features of the Unimog U500 NA 2005 model of the Unimog U500 NA 2005 model Engine: - MB 906 diesel engine; 260 hp at 2,200 rpm, torque 700 ft-lbs, max. rpm: 2,500 - Mercedes-Benz 6-cylinder diesel engine water cooled, turbo charger and intercooler

More information

OPTIONS SLIP-ON FIREFIGHTING UNITS

OPTIONS SLIP-ON FIREFIGHTING UNITS OPTIONS SLIP-ON FIREFIGHTING UNITS 2.0 CF-126 Diesel Pump & Engine The pump shall be a CFE #24193 high pressure centrifugal pump powered by a Briggs & Stratton Vanguard in-line 3 cylinder, water-cooled,

More information

HEAVY DUTY RESCUE. Model DFC VTH

HEAVY DUTY RESCUE. Model DFC VTH HEAVY DUTY RESCUE Model DFC1173-2013 090512-VTH Spartan MetroStar MFD custom cab/chassis with 10" raised roof Four-door cab with six (6) seating positions GAWR Front 18,000 lbs. GAWR Rear 24,000 lbs. Occupant

More information

DANKO STOCK T DANKO PUMPER/TANKER 1,600 Gallon UPF Poly Tank

DANKO STOCK T DANKO PUMPER/TANKER 1,600 Gallon UPF Poly Tank NFPA 1901 COMPLIANCE DANKO PUMPER/TANKER 1,600 Gallon UPF Poly Tank The NFPA 1901 Standard for Automotive Fire Apparatus, 2016 Edition" Chapter 7- Mobile Water Supply, and any other applicable chapters,

More information

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D 1 HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A fire fighting system shall

More information

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A firefighting system shall be

More information

TOWN OF FARRAGUT. Bid Specifications For 2017 Dump Truck. William McKelvey Public Works Director Municipal Center Drive Farragut, TN 37934

TOWN OF FARRAGUT. Bid Specifications For 2017 Dump Truck. William McKelvey Public Works Director Municipal Center Drive Farragut, TN 37934 TOWN OF FARRAGUT Bid Specifications For 2017 Dump Truck William McKelvey Public Works Director TOWN OF FARRAGUT 11408 Municipal Center Drive Farragut, TN 37934 (865) 966-7057 BID SPECIFICATIONS for 2017

More information

QUARTERLY / ANNUAL MOBILE FIRE APPARATUS INSPECTION REPORT. Manufacturer. Serial no. Legend:

QUARTERLY / ANNUAL MOBILE FIRE APPARATUS INSPECTION REPORT. Manufacturer. Serial no. Legend: QUARTERLY / ANNUAL MOBILE FIRE APPARATUS INSPECTION REPORT Inspection date Fire department Apparatus no. Apparatus Manufacturer Model Serial no. Hourmeter _ Chassis Make _ Model VIN Odometer Legend: X

More information

By: 1 By:!/. Ja/JM) Silfl/ejmrjy

By: 1 By:!/. Ja/JM) Silfl/ejmrjy CALL FOR BIDS CITY OF HARDIN, MONTANA Hardin Volunteer Fire Department NOTICE IS HEREBY GIVEN, that the City of Hardin, Montana, will receive bids to furnish the Hardin Volunteer Fire Department with one

More information

CITY OF DERBY Bid No REQUEST FOR BIDS

CITY OF DERBY Bid No REQUEST FOR BIDS CITY OF DERBY Bid No. 2014-031 REQUEST FOR BIDS Sealed bid for One (1) 2015 4wd Ford F550 Fire Squad will be received by the City of Derby, Kansas at City Hall, 611 Mulberry, Derby, Kansas 67037 until

More information

PUMPERS. up to 2000 gpm pumps. up to 1530 gallon tanks. wheelbase as low as 170. up to 600

PUMPERS. up to 2000 gpm pumps. up to 1530 gallon tanks. wheelbase as low as 170. up to 600 PUMPERS up to 1530 gallon tanks up to 600 hp engine wheelbase as low as 170 up to 2000 gpm pumps E-ONE pumpers are the most versatile, durable pumpers on the market. Offering both 3/16 extruded aluminum

More information

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P == B-2000 M-P, PTO, Manual - 2013.002 11/26/13 == SPECIFICATIONS FOR PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P 1 SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE

More information

Deicer Operating Instructions Table of Contents

Deicer Operating Instructions Table of Contents Deicer Operating Instructions Table of Contents FMC FMC FMC/Trump FMC Global Premier Trump Model: LA1000 Model: LMD-2000 Model: T2000 Model: TM1800 Model: 2100TE Model: HC29050 Model: D240 Contents FMC

More information

CITY OF DERBY Bid No REQUEST FOR BIDS

CITY OF DERBY Bid No REQUEST FOR BIDS CITY OF DERBY Bid No. 2014-030 REQUEST FOR BIDS Sealed bid for One (1) 2015 4wd Ford F550 Fire Squad Refurbishment will be received by the City of Derby, Kansas at City Hall, 611 Mulberry, Derby, Kansas

More information

Truck Specs. Sabre 9 Off-Highway GCWR: 242,000. CapacityTrucks.com

Truck Specs. Sabre 9 Off-Highway GCWR: 242,000. CapacityTrucks.com Truck Specs Sabre 9 Off-Highway GCWR: 242,000 CapacityTrucks.com Sabre 9 / Off-Highway - Base Model Base Model Sabre 9 / Off-Highway Basic Overview GCWR: 242,000 Basic Overview Axle: 4x2 Basic Overview

More information

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D 1 SPECIFICATIONS FOR FIRE FIGHTING SYSTEM FIRE FIGHTING AND PIERCING SPECIFICATIONS Scope and General

More information

DANKO STOCK T DANKO PTO DRY SIDE TANKER 3,000 Gallon UPF Poly Tank

DANKO STOCK T DANKO PTO DRY SIDE TANKER 3,000 Gallon UPF Poly Tank NFPA 1901 COMPLIANCE DANKO PTO DRY SIDE TANKER 3,000 Gallon UPF Poly Tank The NFPA 1901 Standard for Automotive Fire Apparatus, 2016 Edition" Chapter 7- Mobile Water Supply, and any other applicable chapters,

More information

Line Body Canopy and Accessories:

Line Body Canopy and Accessories: ATTACHMENT A Heavy Crew Truck Line Body and Accessories Installation. TMWA provided cab & chassis specifications are provided on last page The Cab & Chassis will be a Freightliner (All Other Items Referenced

More information

Type 3 Fire Engine Model 346

Type 3 Fire Engine Model 346 Type 3 Fire Engine Model 346 Issue Date: February 2016 Supersedes: February 2014 Type 3 Fire Engine, Model 346 Supersedes February 2014 Page 1 Table of Contents Record of Revisions 3 1 General 4 1.1 General

More information

Shop Order : Unclassified

Shop Order : Unclassified Shop Order-00-10-15: Unclassified Brookfield Fire & Emergency Services Chief Rod Nielsen PO Box 128 Brookfield, NS B0N 1C0 902-673-3710 902-673-2881 902-673-3471 responder.rod@gmail.com Exp. Date: 04/18/2013

More information

SPECIFICATIONS FOR TRUCK EQUIPPED WITH AERIAL LIFT AND SERVICE BODY Pennsylvania Department of Military and Veteran Affairs

SPECIFICATIONS FOR TRUCK EQUIPPED WITH AERIAL LIFT AND SERVICE BODY Pennsylvania Department of Military and Veteran Affairs Page 1 of 5 SPECIFICATIONS FOR TRUCK EQUIPPED WITH AERIAL LIFT AND SERVICE BODY Pennsylvania Department of Military and Veteran Affairs Insulated Telescopic Articulating type aerial lift with the following

More information

UN-Priced Offers Due: Wednesday, April 25, 2018 at 10:00 a.m. Reverse Auction/Bid: Wednesday, May 9, 2018 starting at 11:00 a.m.

UN-Priced Offers Due: Wednesday, April 25, 2018 at 10:00 a.m. Reverse Auction/Bid: Wednesday, May 9, 2018 starting at 11:00 a.m. LAUDERDALE COUNTY BOARD OF SUPERVISERS 410 Constitution Ave, 11 th Floor Meridian, Mississippi 39301 601-482-9746 Main 601-482-9744 Fax BIDDERS INFORMATION PACKET BID NO: 3809 One (1) or more Single Axle

More information

REQUEST FOR QUOTATIONS

REQUEST FOR QUOTATIONS Public Works Department REQUEST FOR QUOTATIONS 12 14 YARD DUMP TRUCK PURCHASE Due: Thursday, July 27, 2017 No later than 2:00 P.M. Submit to: City of Arroyo Grande Attn: Public Works Department 1375 Ash

More information

COLLEGE COMMUNITY SCHOOL DISTRICT BID SHEET. THREE (3) 78 PASSENGER TRANSIT STYLE SCHOOL BUSES and ONE (1) 65 PASSENGER LIFT BUS

COLLEGE COMMUNITY SCHOOL DISTRICT BID SHEET. THREE (3) 78 PASSENGER TRANSIT STYLE SCHOOL BUSES and ONE (1) 65 PASSENGER LIFT BUS COLLEGE COMMUNITY SCHOOL DISTRICT BID SHEET THREE (3) 78 PASSENGER TRANSIT STYLE SCHOOL BUSES and ONE (1) 65 PASSENGER LIFT BUS Bid #1 Three (3) 2010 (78) Passenger Transit Style School Buses and One (1)

More information

Request for Bids INFORMATION FOR BIDDERS. FURNISH THE CITY OF DERBY, KANSAS, ONE (1)2014 or NEWER TANDEM AXLE 10 YARD DUMP TRUCK w/ PLOW

Request for Bids INFORMATION FOR BIDDERS. FURNISH THE CITY OF DERBY, KANSAS, ONE (1)2014 or NEWER TANDEM AXLE 10 YARD DUMP TRUCK w/ PLOW Request for Bids City of Derby Public Works 2015-027 INFORMATION FOR BIDDERS FURNISH THE CITY OF DERBY, KANSAS, ONE (1)2014 or NEWER TANDEM AXLE 10 YARD DUMP TRUCK w/ PLOW 1. Sealed bids, on the attached

More information

RAMPMASTER SPECIFICATIONS

RAMPMASTER SPECIFICATIONS RAMPMASTER SPECIFICATIONS RAMPMASTER 15,000 GALLON WD STANDARD SPECIFICATION POWER MODULE ENGINE: ENGINE EQUIPMENT: COOLING: AIR INTAKE: EXHAUST: TRANSMISSION: REAR/DRIVE AXLE: FRONT AXLE: AIR BRAKE SYSTEM:

More information

CBRNE HAZMAT. Model HM0875R YONKERS POLICE DEPARTMENT YONKERS, NY

CBRNE HAZMAT. Model HM0875R YONKERS POLICE DEPARTMENT YONKERS, NY CBRNE HAZMAT Model HM0875R YONKERS POLICE DEPARTMENT YONKERS, NY Yonkers PD has placed another Hackney Special Services body into their fleet. This one is designated as a CBRNE (Chemical, Biological, Radiological,

More information

Multi-Service Vehicle Engine Specifications

Multi-Service Vehicle Engine Specifications This specification describes a high performance, articulated side walk tractor that shall support a variety of attachments. The versatility is required to allow operation in all four seasons of the year.

More information

1500 GPM Vision Top Commercial Pumper VS005 Commercial Pumper WS Darley DESCRIPTION QTY

1500 GPM Vision Top Commercial Pumper VS005 Commercial Pumper WS Darley DESCRIPTION QTY 1500 GPM Vision Top Commercial Pumper 102014 DESCRIPTION QTY Cover Sheet 1 General Info 1 Thank You For Your Consideration 1 ---ADMINISTRATION SECTION--- 1 Product Quality And Workmanship 1 NFPA Compliance

More information

Mantis Rerailer. General Specifications

Mantis Rerailer. General Specifications General Specifications 1. Typical Operating Parameters 2. General 1.1 Operating temperatures will typically be between -4 F (-20 C) to 122 F (50 C). 1.2 Relative humidity ranges between 20% and 100%. 1.3

More information

DP A. 75 Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : Fax :

DP A. 75 Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : Fax : DP-2928-0701A 75 Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : 1-800-567-2719 Fax : 1-800-434-2613 www.fire-pumps.com DP-2928-0701A 3 GALLONS FUEL TANK W/ HOLDER 96" 34" 48" OVERFLOW

More information

WORLD CLASS CUSTOM EMERGENCY EQUIPMENT

WORLD CLASS CUSTOM EMERGENCY EQUIPMENT WORLD CLASS CUSTOM EMERGENCY EQUIPMENT PROUDLY MADE IN USA RKO Enterprises is the Premier manufacturer of Fast Attack Skid/Slip-On Units, Truck Fire Rescue Units, Utility Vehicle Fire and/or Rescue Units,

More information

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F450, Ext. Cab, 4 x 4.

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F450, Ext. Cab, 4 x 4. Ford Cab & Chassis Unit is to be installed on a Ford F450, Ext. Cab, 4 x 4. - GVWR : 16,500 lbs - Front Axle : 7,000 lbs - Rear Axle : 12,000 lbs - Scuff plates - Rear limited slip axle - Rear and Front

More information

HEAVY / HAZMAT TRAILER

HEAVY / HAZMAT TRAILER FREIGHTLINER M2-106 2-Door Tractor GVWR: 35,000 lbs Engine: Cummins ISL 330 HP @ 2000 RPM, 2200 GOV RPM, 1000 LB/FT @ 1300 RPM NFPA compliant Ember Screen and fire retardant Donaldson air cleaner 275 AMP

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GENERAL PURPOSE: The purpose of these specifications is to describe for purchase, a 2018 or newer 10-14 passenger airport shuttle bus with rear mounted handicap lift. This bus

More information

As a safety precaution, remove keys from the ignition while working under or around the vehicle.

As a safety precaution, remove keys from the ignition while working under or around the vehicle. CAB AND CHASSIS As a safety precaution, remove keys from the ignition while working under or around the vehicle. 1. Approach Check the overall appearance of vehicle stance (not leaning). Check for signs

More information

DANKO STOCK T DANKO PUMPER/TANKER 3,000 Gallon Dryside Poly Tank

DANKO STOCK T DANKO PUMPER/TANKER 3,000 Gallon Dryside Poly Tank NFPA 1901 COMPLIANCE DANKO PUMPER/TANKER 3,000 Gallon Dryside Poly Tank The NFPA 1901 Standard for Automotive Fire Apparatus, 2016 Edition" Chapter 7- Mobile Water Supply, and any other applicable chapters,

More information

NOTICE TO BIDDERS. ONE (1) NEW TANDEM AXLE TRUCK (cab & chassis)

NOTICE TO BIDDERS. ONE (1) NEW TANDEM AXLE TRUCK (cab & chassis) NOTICE TO BIDDERS The Roscommon County Road Commission will receive sealed bids until 2:00 p.m. on Thursday, March 22. 2012. (Bids will be opened at 2:00 p.m. for tabulation and review. Bid results and

More information

W.S. Darley & Co FIRE APPARATUS SPECIFICATIONS

W.S. Darley & Co FIRE APPARATUS SPECIFICATIONS S Cover Sheet 00-00-4100 FIRE APPARATUS SPECIFICATIONS 1000 GPM CAFS (LSMC) Vision Series Snow Dragon Pumper (1) For Dalian Subway Fire Department Dalian, China Darley Job 3237 APPROVED BY (PRINT NAME):

More information

INTERNATIONAL DT peak 2200rpm

INTERNATIONAL DT peak 2200rpm BRUSH 08-11-17 PAGE 1 OF 9 OES 8632 INTERNATIONAL MODEL NAVISTAR 7400 SFA 4X4 WIDTH 100 HEIGHT 117 LENGTH 306 ANGLE OF APPROACH: 30 DEGREES ANGLE OF DEPARTURE 25 DEGREES GVW 35,000 LBS WHEEL BASE 175 ENGINE

More information

Remount Proposal. Everest Emergency Vehicles 1133 Rankin Street St Paul, MN Eric Olson

Remount Proposal. Everest Emergency Vehicles 1133 Rankin Street St Paul, MN Eric Olson Remount Proposal Customer Dealer Everest Emergency Vehicles 1133 Rankin Street St Paul, MN 55116 651-236-8943 Eric Olson Module: INFORMATION 0.1.60 ****** Ambulance Re-chassis / Refurbish ****** * * Old

More information

MONTGOMERY COUNTY PUBLIC WORKS DEPARTMENT P. O. BOX 663 INDEPENDENCE, KANSAS PH FAX

MONTGOMERY COUNTY PUBLIC WORKS DEPARTMENT P. O. BOX 663 INDEPENDENCE, KANSAS PH FAX MONTGOMERY COUNTY PUBLIC WORKS DEPARTMENT P. O. BOX 663 PH. 620-330-1170 - FAX 620-330-1177 MEMO To: From: Dump Truck Bidders Jim Wright Asst. Public Works Coordinator Date: February 23 rd 2016 Subject:

More information

HIGH VELOCITY PUMP PUMP END

HIGH VELOCITY PUMP PUMP END HIGH VELOCITY PUMP USFP pumps are designed for firefighting and high volume water supply in industrial, oil and gas, nuclear, municipal, and marine applications. The USFP High Velocity Pump is designed

More information

DP Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : Fax :

DP Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : Fax : DP-1427-0701 75 Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : 1-800-567-2719 Fax : 1-800-434-2613 www.fire-pumps.com DP-1427-0701 ELECTRIC HOSE REEL w/ 3 WAY ROLLERS w/ 150' x 1"

More information

ALLEGAN COUNTY ROAD COMMISSION PROPOSAL FOR WESTERN STAR TANDEM REAR AXLE DUMP TRUCKS (CAB & CHASSIS) MINIMUM 64000# GVWR

ALLEGAN COUNTY ROAD COMMISSION PROPOSAL FOR WESTERN STAR TANDEM REAR AXLE DUMP TRUCKS (CAB & CHASSIS) MINIMUM 64000# GVWR ALLEGAN COUNTY ROAD COMMISSION PROPOSAL FOR WESTERN STAR TANDEM REAR AXLE DUMP TRUCKS (CAB & CHASSIS) MINIMUM 64000# GVWR Board of County Road Commissioners of the County of Allegan 1308 Lincoln Road Allegan,

More information

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements

More information

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi)  Stainless Steel  Polymer AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) akronbrass.com Heavy Duty Brass Swing-Out Valves Akron Brass offers a wide variety of apparatus valves to meet the demands of today s fire service. All

More information

SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU Lts.

SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU Lts. SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU - 6000 Lts. GENERAL:- The Vehicle Mounted Suction Unit shall be robust in construction and shall be used to create a vacuum for syphoning

More information

July 15, 2016 NOTICE INVITING BIDS NOTICE TO SUPPLIERS FOR FURNISHING MOTOR VEHICLES

July 15, 2016 NOTICE INVITING BIDS NOTICE TO SUPPLIERS FOR FURNISHING MOTOR VEHICLES July 15, 2016 NOTICE INVITING BIDS NOTICE TO SUPPLIERS FOR FURNISHING MOTOR VEHICLES 1. Sealed bids will be received by Carmichael Water District (District) for furnishing motor vehicles as set forth in

More information

ONE (1) CURRENT MODEL YEAR REGENERATIVE AIR TYPE STREET SWEEPER MOUNTED ON CONVENTIONAL CAB BID NO

ONE (1) CURRENT MODEL YEAR REGENERATIVE AIR TYPE STREET SWEEPER MOUNTED ON CONVENTIONAL CAB BID NO CITY OF SAN LEANDRO INVITATION FOR BIDS SUBMIT BID TO: City of San Leandro Purchasing Department 835 East 14th Street San Leandro, CA 94577 FOR FURTHER INFORMATION CONTACT: Julie Jenkins Purchasing Agent

More information

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F350, 2 Doors Regular Cab, 4 x 4.

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F350, 2 Doors Regular Cab, 4 x 4. Ford Cab & Chassis Unit is to be installed on a Ford F350, 2 Doors Regular Cab, 4 x 4. - GVWR : 11,000 lbs - Front Axle : 6,000 lbs - Rear Axle : 7,050 lbs - 4.10 Limited Slip Axle - Transfer case skid

More information

Specification Sheet Form Rev

Specification Sheet Form Rev Sales Administration Use Only Customer Quote Number Quote Revision Shop Order Number Serial Number(s) Date : Customer Name Salesperson Model : Salesperson Name : 8400 DDC S1 Part / Drawing Number : 730-8400

More information

2017 Single Axle 5 CU.YD. Dump Truck Specifications. Minimum Specifications 33,000 lb

2017 Single Axle 5 CU.YD. Dump Truck Specifications. Minimum Specifications 33,000 lb 2017 Single Axle 5 CU.YD. Dump Truck Specifications Item GVW Wheelbase Cab to Axle Minimum Specifications 33,000 lb 158 inches 84 inches Tires 11R x 22.5, Tubeless, 14 ply, All weather mud and snow tread

More information

SPECIFICATIONS FOR 4X4 SINGLE AXEL PLOW TRUCK. City of Negaunee

SPECIFICATIONS FOR 4X4 SINGLE AXEL PLOW TRUCK. City of Negaunee SPECIFICATIONS FOR 4X4 SINGLE AXEL PLOW TRUCK City of Negaunee The following specification describes the minimum requirements for a 4x4 single axel plow truck for the City of Negaunee. The equipment bid

More information

HEAVY RESCUE. Model DF0976. PUMPKIN CENTER FIRE DEPARTMENT - Jacksonville, NC

HEAVY RESCUE. Model DF0976. PUMPKIN CENTER FIRE DEPARTMENT - Jacksonville, NC PUMPKIN CENTER FIRE DEPARTMENT - Jacksonville, NC Pumpkin Center is a district adjoining the City of Jacksonville on the northeast. Jacksonville is home to Camp Lejeune Marine Corp Base and Expeditionary

More information

GENERAL SPECIFICATION

GENERAL SPECIFICATION ALPHA 2001 MD TMA (Truck Mounted Attenuator GENERAL SPECIFICATION I. GENERAL A. All ALPHA 2001 MD Truck Mounted Attenuators (ALPHA 2001 MD TMA) shall be designed and manufactured by Energy Absorption systems,

More information

TMS x 4 & 6 x 6

TMS x 4 & 6 x 6 TMS5 6 x 4 & 6 x 6 Dimensions 8' (2438) TAILSWING 11' 1" (3383) 7' 8" (2337) RET 13' 9-3/4" (4210) MID EXT ' (96) EXT Note: ( ) Reference dimensions in mm 16-3/4" (425) 43' 4" (13 8) OVERALL 10' 10" (32)

More information

TECHNICAL RESCUE TRAILER

TECHNICAL RESCUE TRAILER FREIGHTLINER M2-112 2-Door Tractor GVWR: Tractor 35,000 lb.; Combination tractor and trailer - 60,000 lb. Engine: Detroit DD13, 12.8L; 410 HP @ 1800 RPM, 1800 RPM governed, 1550 lb/ft @ 1100 RPM NFPA compliant

More information

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection.

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection. Zip's Truck Equipment 316 W. Milwaukee Street New Hampton, Iowa 50659 Phone: 641-394-3166 Fax: 641-394-4044 Visual Inspection Page: 1 of 6 Customer: Address: Division: Phone: null Reference #: 2NPRLZ9X37M730087

More information

Customer Proposal. Rush Medium Duty Truck Center, Dallas Irving Blvd., Dallas, Texas, Office: Prepared for: Prepared by:

Customer Proposal. Rush Medium Duty Truck Center, Dallas Irving Blvd., Dallas, Texas, Office: Prepared for: Prepared by: Customer Proposal Prepared for: Lonnie Sullivan Republic Services 18500 N. Allied Way Phoenix, AZ 85054 Prepared by: Gary Gibson Office: 214-678-5922 Email: gibsong@rushenterprises.com Date: 01/27/2017

More information

FLAT BED STAKE BODY TRUCK

FLAT BED STAKE BODY TRUCK Group 1 Contract Attachment 4 Price Sheet: Dump Trucks Please see Attachment D: Instruction and General Information for Instructions, Color Key, and Reference Key. GVWR* Code 2 Base Vehicle Description3

More information

An ISO 9001:2000 Certified Company Autocar MY x DOT/EPA Compliant Terminal Tractor Standard Specifications

An ISO 9001:2000 Certified Company Autocar MY x DOT/EPA Compliant Terminal Tractor Standard Specifications An ISO 9001:2000 Certified Company Autocar MY 2015 4x2 2013 DOT/EPA Compliant Terminal Tractor Standard Specifications Engine and Equipment Standard Optional Engine model Exhaust Air cleaner Radiator Fan

More information

CITY OF ALHAMBRA NOTICE INVITING BIDS NO. N2M16-144

CITY OF ALHAMBRA NOTICE INVITING BIDS NO. N2M16-144 CITY OF ALHAMBRA NOTICE INVITING BIDS NO. N2M16-144 PUBLIC NOTICE IS HEREBY GIVEN that the City of Alhambra will receive sealed bids on or before the hour of 10:30 AM on Thursday, October 27 2016, at the

More information

NOTICE OF BID. The City of Pigeon Forge is receiving bids on one knuckle boom trash loader for the sanitation department.

NOTICE OF BID. The City of Pigeon Forge is receiving bids on one knuckle boom trash loader for the sanitation department. NOTICE OF BID The City of Pigeon Forge is receiving bids on one knuckle boom trash loader for the sanitation department. Specifications may be obtained from the Public Works Department at City Hall between

More information

Barrow County Board of Education 179 W. Athens Street Winder, Georgia 30680

Barrow County Board of Education 179 W. Athens Street Winder, Georgia 30680 Barrow County Board of Education 179 W. Athens Street Winder, Georgia 30680 Judy Roberts Telephone: 770-867-4527 x100214 Business Services Fax: 770-867-4540 E-Mail: jroberts@barrow.k12.ga.us Barrow County

More information

MSV. Innovating for you

MSV. Innovating for you MSV Innovating for you Innovating for you - A new generation of multi-service vehicles CAB SAFETY Operators enclosure is ROPS certified to SAE J 1040C and ISO 3471 at 12,000 lbs. IN CONTROL Sure Grip Controls

More information

Customer Proposal. Rush Medium Duty Truck Center, Dallas Irving Blvd., Dallas, Texas, Office: Prepared for: Prepared by:

Customer Proposal. Rush Medium Duty Truck Center, Dallas Irving Blvd., Dallas, Texas, Office: Prepared for: Prepared by: Customer Proposal Prepared for: Lonnie Sullivan Republic Services 18500 N. Allied Way Phoenix, AZ 85054 Prepared by: Gary Gibson Office: 214-678-5922 Email: gibsong@rushenterprises.com Date: 01/26/2017

More information

City of New Haven. 101 FRONT STREET PO BOX 236 NEW HAVEN, MO Phone * * Fax

City of New Haven. 101 FRONT STREET PO BOX 236 NEW HAVEN, MO Phone *  * Fax City of New Haven 101 FRONT STREET PO BOX 236 NEW HAVEN, MO 63068 Phone 573-237-2349 * www.newhavenmo.org * Fax 573-237-4696 August 20, 2014 Request for Bids, Medium Duty Truck City of New Haven The City

More information

ADDENDUM 2. The following clarifications, changes, additions, and/or deletions are hereby made to the RFB:

ADDENDUM 2. The following clarifications, changes, additions, and/or deletions are hereby made to the RFB: Date: January 2, 2018 ADDENDUM 2 RFB No: FS-07-18 / Haul Truck Bid Date: January 11, 2018/2:00 PM Local Time The following clarifications, changes, additions, and/or deletions are hereby made to the RFB:

More information

Customer Proposal. Rush Medium Duty Truck Center, Dallas Irving Blvd., Dallas, Texas, Office: Prepared for: Prepared by:

Customer Proposal. Rush Medium Duty Truck Center, Dallas Irving Blvd., Dallas, Texas, Office: Prepared for: Prepared by: Customer Proposal Prepared for: Chris Limongelli Republic Services 14400 N. 87th St, Suite 200 Scottsdale, AZ 85260 Office: 480-718-6528 Mobile: 602-369-1776 Email: climongelli@republicservices.com Prepared

More information

IC-20-G. Engineering Spec. View thousands of Crane Specifications on FreeCraneSpecs.com. Page 1 of 7 Date: June 2006

IC-20-G. Engineering Spec. View thousands of Crane Specifications on FreeCraneSpecs.com. Page 1 of 7 Date: June 2006 Engineering Spec IC-20-G Page 1 of 7 Replaces: Form BD104G Dated: May 2004 The IC-20-1G is a self-propelled industrial crane designed for in-plant lifting and material handling applications. It is powered

More information

City of Lewiston. Finance Department Allen Ward, Purchasing Agent

City of Lewiston. Finance Department Allen Ward, Purchasing Agent City of Lewiston Finance Department Allen Ward, Purchasing Agent 2018-008 Compact Sidewalk Sweeper December 21, 2017 Sir/Madam: Sealed Proposals will be received in the office of the Purchasing Agent,

More information

City of Storm Lake Fire Department Heavy Rescue Specifications

City of Storm Lake Fire Department Heavy Rescue Specifications INTENT OF SPECIFICATIONS City of Storm Lake Fire Department Heavy Rescue Specifications It shall be the intent of these specifications to provide a complete apparatus equipped as hereinafter specified.

More information

M-B Companies, Inc. Specification. Model 155 PLS-155. Palletized Striper. High Pressure Airless. 2 x 55 Gallon Drum. Standard Rev. 2 January 11, 2008

M-B Companies, Inc. Specification. Model 155 PLS-155. Palletized Striper. High Pressure Airless. 2 x 55 Gallon Drum. Standard Rev. 2 January 11, 2008 M-B Companies, Inc. Administration Pavement Marking Equipment Divisions 1615 Wisconsin Avenue EAST COAST DIVISION WEST COAST DIVISION P.O. Box 200 79 Montgomery Street 2490 Ewald S.E. New Holstein, WI

More information

TH406 / TH407 Recommended Parts List

TH406 / TH407 Recommended Parts List Basic Engine & Related System (Mechanical) Primary Fuel Filter - Mechanical 1R-1804 Secundary Fuel Filter - Mechanical 252-6338 Air Filter Primary Element 206-5234 Air Filter Secondary Element 206-5235

More information