Using the DPS Series Heated Dew Point/ Humidity Hygrometer

Size: px
Start display at page:

Download "Using the DPS Series Heated Dew Point/ Humidity Hygrometer"

Transcription

1 ALICATION NOT 06_Nov DS ev sing the DS Series Heated Dew oint/ Humidity Hygrometer The DS series of heated chilled mirror hygrometers are designed to extract a gas sample from a heated process and measure its dew point. The DS is designed to measure dew point in the range of +9 C (0 F) to as low as - C (- F). ach model within the series consists of an optical chilled mirror hygrometer that is designed to continuously measure the moisture content of heated gases. The three models are the DS standard unit, the DS featuring the ability to measure and automatically compensate for pressure, and the DS deluxe unit that offers an advanced display, operational software and interface options. hy use a heated Hygrometer? hen the dew point temperature of a sampled gas is at a higher temperature than that of the sensing system, a condition of saturation or 00% elative Humidity will occur within the sensing system. This causes liquid water to form within the tubing and internal portions of the sensing system and utlimately causes a sytem failure. nder these conditions, reliable dew point reading are not possible. The solution to this problem is to heat all of the componenents of the sensing system to a temperature above the dew point temperature of the sampled gas. The DS series heated hygrometers have been specifically designed to solve this problem. The entire sampling system within each model including the chilled mirror sensor are heated. A heated sampling hose is provided to make connection to the process measuring point. The heated sensor allows the measurement of high dew points that are above ambient temperature. ithout the heated system condensation would occur and measurements could not be taken. The DS series uses the chilled mirror (C) dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a precision platinum resistance thermometer to measure the mirror temperature. The C uses a thermo-electric device to control the temperature of the mirror in determining dew point. Since it is a direct measurement of dew point and thus a rimary Standard easurement Technique, the DS is highly regarded by pharmaceutical companies for monitoring fluidized beds, gas analysis laboratories, fuel cell testing facilities, air separation equipment, furnace operations and manufacturing facilities for its accuracy, quick dry down, fast response in detecting upset conditions and long life characteristics. ALICATIONS ood Veneer Drying Combustion rocesses Leakage testing: Nuclear eactors Fluidized Beds roduct Drying Chambers Bakeries xothermic rocess Chamber Fuel Cell Testing Furnace Applications harmaceutical owder Drying levated Temp rocess Chambers lastics/ olding rocess Chemical eactors Heat Treat/ Annealing Ovens Inc. 99 iver oad. Hudson. A. 079 ain: + (08) Fax:+ (08)

2 D Common to all DS odels: All standard dgetech DS models are designed for use with positive pressure sample gas. An vacuum pump option is available for sample extraction for near ambient pressure samples. The standard DS heated sampler includes a sample flow meter/valve, SS/ TF tubing and fittings, integrated heater and emergency thermal shutoff circuit all housed within an insulated NA enclosure. A ower ON- switch is located on the analyzer electronics enclosure. The sample inlet is equipped with an externally mounted VAC powered heated sample hose (/T) to ensure no vapors condense into the sampling lines. A sintered metal filter is provided within the heated enclosure to help prepare the sample gas for measurement. The NA painted steel enclosure is heated by an internal heater system and maintains a temperature above that of the sampled gas The temperature of the heated package is maintained by a control module located on the front panel of the electronics enclosure. The temperature may be adjusted via accessible buttons on the control module without the need to access the interior of the enclosure. An optional Loss of Sample Flow alarm is also available for all models to detect a clogged filter, malfunctioning pump or sample line blockage. DS: The DS heated chilled mirror hygrometer system includes an HTS heated stage sensor. This integrated system consists of two enclosures. An I6 plastic enclosure that includes a microprocessor based electronics is mounted to the door of the sampling system. Button access to the microprocessor electronics is available to enter the analyzer software setup. The door of the analyzer electronics enclosure must be opened to access the buttons. Changes may be The DS is configured with the HTS ( stage chilled mirror) dew point sensor designed for use in high temperature environments. D.7C Ts. C Tx. C X DS HATD DOINT SYST HATD SAL INLT HOS DS: Similar to the DS except this unit also includes pressure measurement and pressure-dew point compensation. A pressure transducer (rated for the heated environment) is mounted within the sampling system downstream of the sensor. ressure is displayed on the Digital Display and the option for automatic pressure compensation of Dew oint is available. The DS also provides front panel button access to initiate an Automatic ABC to compensate for mirror contamination plus a display button to scroll through viewing of measured parameters. Other features of the DS include analog outputs, relay alarm outputs, and serial interface. Sensor choices include the HTSx standard aluminum body or the HTX stainless steel body (for use with chemically aggressive sample gases). D 7.7 C ABC DS HATD DOINT SYST DISLAY HATD SAL INLT HOS Inc. 99 iver oad. Hudson. A. 079 ain: + (08) Fax:+ (08)

3 JAN 0 ::0 A SVOLOCK 7.0 C D.7 C AT 6. % H CHILLD IO HYGOT D C/F HAT Dewaster ABC COOL SC 0 NT SS NT FO N ABC DISLAY D D.7C Ts. C Tx. C X ON AC INT 9-0 VAC 0-60 HZ AD IN SA FS SIAL JAN 0 ::0 A SVOLOCK ABINT T. SS LAY LAY FAN O ANALOG OT ANALOG OT ANALOG OT C/F HAT ABC COOL SS NT FO N SNSO CABL DS: Same as the DS except the microprocessor system is replaced by an externally mounted Dewaster deluxe hygrometer. ressure measurement and compensation is optional. The Dewaster offers many features including programmable alarms (), analog outputs (), S- Serial Interface, a multi-line full feature display and keypad, troubleshooting and diagnostic control, as well as a full set of display functions. The Dewaster is connected to the sampling system via a -meterlong communications cable with a quick connection interface at the Dewaster. The DS HATD DOINT SYST Dewaster is standard as a table top unit or may be purchased in a NA enclosure. Sensor choices include the HTSx standard aluminum body or the HTX stainless steel body (for use with chemically aggressive sample gases). New, Cart Version: All three models in the DS series are available in a transportable cart version. This allows the DS model to be moved around within a facility to access a variety of process points. Includes portable steel frame cart with 0 foot (m) heated sampling hose with ¼ inch connector and a 0 foot power cord. ounting clips for the hose and power cord are supplied. O COD Temperature Control odlue HATD SAL INLT HOS Optional Flow Alarm Light O ON Optional Control Switches Sample xhaust Key Lock dgetech Instruments 7.0 C D.7 C AT 6. % H CHILLD IO HYGOT Dewaster A ANL O COD Dewaster SC 0 NT dgetech Instruments D 7.7 C DS HATD DOINT SYST DS HATD DOINT SYST DS HATD DOINT SYST Inc. 99 iver oad. Hudson. A. 079 ain: + (08) Fax:+ (08)

4 DS STANDAD FATS OTIONAL VAC HTS SNSO SL OTIONAL SITCH T TINAL BLOCK HATD SAL INLT HOS ANING DANG! DO NOT LAC HANDS ND LAT FILT SAL XHAST Chilled mirror sensor Sensor Temperature ange: 0 to 99 C (68 to 0 F) Dew oint ange: - to 9 C (- to 0 F) easurement Accuracy: ±0. C (±0. F) icroprocessor Controlled Dew oint and Temperature Displays ser rogrammable Temperature Controller Automatic Balance Control Integral Adjustable Flowmeter Two Available Alarm elays Selectable Analog Outputs, Serial S Output Sample Connection: ¼ inch Compression Fitting foot Heated Hose Supplied for sample input Sample ressure: p to 0psig VAC ower: 0 or 0VAC, 0/60Hz, 0 atts ST SCIFY VOLTAG odel Specific erformance Features DS: indow rotects ode/ Adjustment Buttons and Display, S- Serial access to menu DS: Offers ressure Dew oint easurement, Button Access anual ABC, and Viewing of arameters from the front panel. Operation settings may be configured at dip switches within the analyzer DS: Optional ressure Dew oint easurement and a Full Feature Alpha-Numeric Display and Keypad offers easy access to ser Friendly operations menu ADDITIONAL DS OTIONS Sample Flow Switch (ax temperature of enclosure is 0C) Sample Flow Alarm Lamp (ax temperature of enclosure is 0C) Vacuum ump BNFITS of the Chilled irror Sensor: liminate Dewoint sensor failures due to water condensation in sampling system Direct measurement method: recognized as a rimary Standard Technique Improve Sensor recision and Stability with our customized heated sampling system obust and Long Life: no moving parts, no consumable components Inc. 99 iver oad. Hudson. A. 079 ain: + (08) Fax:+ (08)

5 Sensor irror Choices Chilled irror Compatibility Chart Applications C Configuration General urpose Gases Acids Caustics Salts Organics Nuclear Application High Temperature Chrome lated Copper A D D C C D C 6 Stainless Steel A B B B B C B latinum A A A A A A A Teflon Coated Chamber A A A A A D D High ressure Chamber A N N N N N A A B C D N xcellent Very Good Good Not recommended Not ated TO OD TH DS series:. Select Base odel. Select Sensor Type: DS only available with the HTS. DS and DS available with HTSx standard aluminum body or the HTX stainless steel body (for use with chemically aggressive sample gases).. Select Sensor irror Type- Chrome (standard), Stainless Steel, or latinum. latinum is generally recommended for aggressive environments and for nuclear applications.. Select Options such as Vacuum ump. If you need to measure dew point at pressure, see the DS or the DS. List as separate line items : Accessories, Calibration ackages, and xtended arranty. DS- HTS SNSO TY IO TY OTIONS O CONTY DS SNSO TY IO TY OTIONS O CONTY DS SNSO TY IO TY OTIONS O CONTY Inc. 99 iver oad. Hudson. A. 079 ain: + (08) Fax:+ (08)

6 D ABC DISLAY D SL ON AC INT 9-0 VAC 0-60 HZ AD IN SA FS SIAL JAN 0 ::0 A SVOLOCK ABINT T. SS LAY LAY FAN O ANALOG OT ANALOG OT ANALOG OT C/F HAT ABC COOL SS NT FO N SNSO CABL DS OTIONS -FS Sample Flow Detection: Sample Flow Switch with SST Dry Contacts -FSL Sample Flow Detection: Sample Flow Switch Triggers ed Lamp Alarm -VH Vacuum ump to extract sample flow from process to the sensor -CAT Cart ount, specify model analyzer -0HOS xtended length sample hose, 0 foot long Y Year xtended arranty covers all repairs within the warranty statement YNIST calibrations for the price of (Dewoint) D.7C Ts. C Tx. C X OTIONAL VAC OTIONAL SITCH SAL XHAST DS HTS SNSO T ANING DANG! DO NOT LAC HANDS HATD DOINT SYST ND LAT FILT TINAL BLOCK HATD SAL INLT HOS HATD SAL INLT HOS Temperature Control odlue Optional Flow Alarm Light Optional Control Switches Sample xhaust Dewaster A ANL D 7.7 C Key Lock DS HATD DOINT SYST DS HATD DOINT SYST dgetech Instruments 7.0 C D.7 C AT 6. % H Dewaster SC 0 NT CHILLD IO HYGOT O COD HATD SAL INLT HOS O COD HATD SAL INLT HOS Inc. 99 iver oad. Hudson. A. 079 ain: + (08) Fax:+ (08)

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer APPLICATION NOTE 0_- DewMaster Rev Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer The Model DewMaster is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously

More information

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement

More information

Optidew Vision Optical Dew-Point Meter

Optidew Vision Optical Dew-Point Meter Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,

More information

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON. C H I L L E D M I R R O R HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON. 1 2 3 4 5 6 7 8 9 M O D E L E 4 The Model E4 is a general purpose chilled mirror dew point hygrometer which provides optional

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2100/2200 FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER MODEL 2100: Constant face velocity, variable volume MODEL 2200: Constant face velocity, variable volume

More information

Environmental/Analytical LabCivil Engineering Lab Equipment

Environmental/Analytical LabCivil Engineering Lab Equipment DIGITAL PH METER Display : 3.5 Digit LED. Range : ph 0 to 14.00, mv 0 to ± 1999. Resolution : ph 0.01, mv 1. : ph ± 0.01, mv ± 1 mv. Temp. Compensation : Auto 0 to 100 deg. C., Manual 0 to 100 deg. C.

More information

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7 Features User Accessible Memory for Test Configuration Management ±0.05% FS System Accuracy EU Throughput Rates of 500 Hz Auto-Negotiating 10/100 BaseT Ethernet with TCP & UDP Protocol Pressure Ranges

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range Valve Solutions w w w. m k s i n s t. c o m Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves Isolating and close-loop controlling each variable

More information

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS SPECIFICATIONS 1 PRINCIPLE OF OPERATION 1 INSTALLATION 2 Choosing a Sampling Location 2 Mounting the Enclosure 2 Remote Alarm

More information

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology zfa01 Global Filtration Technology 157 Why on-site fluid analysis? Certification of fluid cleanliness levels Immediate and accurate results Early warning tool to help prevent catastrophic failures in critical

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

1/16 DIN Temperature Controller E5CS

1/16 DIN Temperature Controller E5CS 1/16 DIN Temperature Controller Automatic Adjustment and ID Control in a 48x48-mm ackage Control accuracy to ±1% of full scale Selectable temperature ranges in C or F Easy-to-read 13.4-mm high LED display

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry.   FEATURES DESCRIPTION High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry FEATURES Primary standard, dimensionally based piston prover system Accuracy: CalTrak 500: up to +/- 0.35% of reading mass

More information

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

DIN Rail Power Module

DIN Rail Power Module 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A www.lutron.com +44.(0)20.7702.0657 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller DIN Rail odule The DIN Rail odule family

More information

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology Excellence in gas analyzers since 1957 Over 180 years of JY optical experience The expertise of Horiba combustion technology EMIA SERIES C ARBON/SULFUR A NALYZERS A World Ahead in AnalyzerTechnology The

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features Electronic Control Valve ressure control Flow control Leakage control Level control emperature control Mixture control at mixing junction he Electronic Control Valve combines the advantages of an excellent

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

DIFFERENTIAL PRESSURE BATTERY CHARGERS

DIFFERENTIAL PRESSURE BATTERY CHARGERS DIFFERENTIAL PRESSURE BATTERY CHARGERS CONVERTING PIPELINE ENERGY TO BATTERY POWER Free Uninterruptible Power 24/7 ISO 9001:2008 Certified Quality System 10-20 Watt Units Available POWER SYSTEMS 12 or

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand CAMS Combustion Airflow Management System Proven solutions for a tough industry Precision Airflow Measurement An ONICON Brand CAMS TM Combustion Airflow Management System Product Description The Air Monitor

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics Cryogenic Liquid Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics A Versatile Level Measurement System... A Variety of Liquids Nitrogen

More information

13. Evaporative Emission Control System

13. Evaporative Emission Control System 85 13. Evaporative Emission Control System General The evaporative emission control system prevents the fuel vapors that are created in the fuel tank from being released directly into the atmosphere. The

More information

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe E-MAIL: 1/7 Sensor (Carbon dioxide) for the detection of CO2 Features High selectivity to CO 2 Long-term stability Low dependency on humidity & temperature Applications Air quality control Agriculture

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS Online data sheet A B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type Part no. On request The exact device specifications and performance data of the product

More information

Tracer VM with User Interface

Tracer VM with User Interface Tracer with User Interface Flowmeter with FCI (Fluid Characteristic Indication) Operating Instructions General The Tracer Flowmeter provides: 0 to 5V or 0 to 10V Selectable Analog Flow Output 0 to 5V or

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

DD1 Differential Pressure Gauge Single Diaphragm Type

DD1 Differential Pressure Gauge Single Diaphragm Type DD Differential ressure auge Special eatures approved electrical contacts Case & measuring system in SS Dry or liquid filled Standard followed in general EN 87 - pplication Suitable for clean air Compatible

More information

The PMAC Dynamic Scale Loop

The PMAC Dynamic Scale Loop The Dynamic Scale Loop Original System for evaluation of scaling tendency and inhibitor performance The System is an invaluable research and development tool for technologists responsible for the design,

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013 Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box

More information

Flash Point Process Analyzer

Flash Point Process Analyzer Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008 FurnaceDoctor -DPT Dewpoint Analyzer User Manual Version 008 Manual FurnaceDoctor -DPT - Version 8 Page 2 of 13 Manual #: 003 Rev No: 8 COPYRIGHT (C) No part of this publication may be reproduced, transmitted,

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

Actuators IC 20, IC 40

Actuators IC 20, IC 40 Actuators IC 20, roduct brochure GB 3 Edition 06.14 IC 20 for applications with continuous or three-point step control and Automatic/anual mode changeover for easy commissioning, IC 20..E with electronic

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

3000 SERIES DRY-BLOCK HEAT SOURCE

3000 SERIES DRY-BLOCK HEAT SOURCE 3000 SERIES DRY-BLOCK HEAT SOURCE USER MANUAL Please read this manual before switching the unit on IMPORTANT safety information inside TABLE OF CONTENTS 1 INTRODUCTION 1 2 SAFETY 2 3 OPERATION 3 3.1 Parts

More information

Valve Products. Viking Lite Series Valves. Operating information. Minimum operating pressure, PSIG (bar) Materials. Recommended air quality for valves

Valve Products. Viking Lite Series Valves. Operating information. Minimum operating pressure, PSIG (bar) Materials. Recommended air quality for valves atalog 000-US arker neumatic Valve roducts Viking ite Valves The Viking ite valve range is robust, versatile and combines a large flow capacity with short change-over times, designer may choose /8, / or

More information

ADJUSTABLE FREQUENCY CRANE CONTROLS

ADJUSTABLE FREQUENCY CRANE CONTROLS IMPULSE G+ MINI ADJUSTABLE FREQUENCY CRANE CONTROLS The IMPULSEG+ Mini from Magnetek continues our history of providing the most reliable and cost-effective adjustable frequency crane controls available.

More information

IC18DV/92/SCP - Multipurpose Distillation Plant with Automatic Control

IC18DV/92/SCP - Multipurpose Distillation Plant with Automatic Control CHEMICAL ENGINEERING IC18DV/92/SCP - Multipurpose Distillation Plant with Automatic Control - Code 991215 IC18DV/92/SCP - Multipurpose Distillation Plant with Automatic Control DIDACTA Italia S.r.l. -

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Recirculating Coolers

Recirculating Coolers SELECTION GUIDE (General Models) (Low Temp. Models) (Advanced Low Temp. Models) (High Temp. Models) General Models Low Temp. Models Advanced Low Temp. Models High Temp. Models HX-20 Working Cooling Temp.

More information

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. Environmentally friendly Ultra Deep Freezer, -40 degree powered by Meditech Technology for safe storage. Stable Temperature Control Temperature is

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011 Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS DESCRIPTION Honeywell Zephyr Digital Airflow Sensors: HAF Series-High Accuracy, provide a digital interface for reading airflow over the specified full scale flow span and temperature range. Their thermally

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER Design Specifications DS-9900 Revision 04 9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER 2-Wire loop powered flowmeter/transmitter 316 Stainless steel measuring unit Automatic temperature

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

Tracer VMA with AutoReg

Tracer VMA with AutoReg Tracer with AutoReg Flowmeter with Automatic Flow Regulation Operating Instructions RoHS Compliant General The Tracer Flowmeter with AutoReg provides: Analog Flow Output (Selectable 0 to 3.5V, 0 to 5V

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Valve Products Viking Lite Valves

Valve Products Viking Lite Valves atalog 0697- arker neumatic alve roducts iking ite alves The iking ite valve range is robust, versatile and combines a large flow capacity with short change-over times, designer may choose /8, / or /8

More information

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre Inline Flowmeter for compressed air and gases DN15 - DN50 / 16 bar The flow meter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow of

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the

More information

ES20 Compact Sampling System Stainless Steel Sampling System

ES20 Compact Sampling System Stainless Steel Sampling System ES0 Compact Sampling System Stainless Steel Sampling System Dew-Point Sampling The ES0 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a wide variety

More information

E v a p o r a t o r s

E v a p o r a t o r s E v a p o r a t o r s Ni Evaporator 11 to 96 Needles These systems have has a flow meter attached to the side for controlling the gas flow to the equalizer manifold giving equal gas flow to each well.

More information

Ventilation Control. Ventilation Control 12

Ventilation Control. Ventilation Control 12 Ventilation Control One of our major markets is building automation where our sensors control individual fans, dampers, valves, etc. A common application is controlling ventilation in rooms with varying

More information

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series - High Accuracy Honeywell Zephyr HAF Series sensors provide

More information

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL Macintyre Electronic Design Associates Inc. 43676 Trade Center Place, Suite 145, Dulles, VA 20166 Phone: (703) 996-8990 FAX: (703) 996-8770 e-mail: sales@meda.com THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

Acid Resistant AVC6000

Acid Resistant AVC6000 Accutrol, LLC Product Sheet Acid Resistant AVC6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare Innovative features for the AVC6000! AHR Expo AWARDS WINNER Intuitive Graphical

More information

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) LAKEWOOD INSTRUMENTS MODEL 260 SERIES BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006 Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6 The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

Stirrers. DAIHAN Scientific. Magnetic Stirrers, Magnetic Stirring P. 197~200, Magnetic Stirring with Heating P. 201~207

Stirrers. DAIHAN Scientific. Magnetic Stirrers, Magnetic Stirring P. 197~200, Magnetic Stirring with Heating P. 201~207 DAIHAN Scientific Stirrers Magnetic Stirrers, Magnetic Stirring P. 197~200, Magnetic Stirring with Heating P. 201~207 Digital Magnetic Stirrer MaXtir TM 500S 80~1,500 rpm Digital Magnetic Stirrer MS-20D

More information

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features Description BECSys CO 2 Feed Systems provide a rugged and reliable solution to ph control in aquatics facilities. CO 2 is recognized as a safe and easy-to-use method for ph control. BECSys CO 2 Feeder

More information

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

EMERSON CLIMATE TECHNOLOGIES-EX

EMERSON CLIMATE TECHNOLOGIES-EX EMERSON CLIMATE TECHNOLOGIES-EX Valves & Controls EX4-EX8 Control Valve The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems.

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Vacuum Gauge Catalog

Vacuum Gauge Catalog 2019 Vacuum Gauge Catalog Possibly The World s Best Gauge Tubes! 1/8 in. NPT Standard Internal Volume Only 0.78 cc Working Pressure to 300 PSI (Tested to 1200 PSI) NO PLASTIC! Pirani Gauges 1 to 2000 mtorr.01

More information

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application 2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator

More information

An ISO 9001 company IPB-AL ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ALUMINUM INDUSTRY. BECK VIDEO Scan w/ Smartphone

An ISO 9001 company IPB-AL ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ALUMINUM INDUSTRY. BECK VIDEO Scan w/ Smartphone IPB-AL An ISO 9001 company R ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ALUMINUM INDUSTRY BECK VIDEO Scan w/ Smartphone Rugged & Dependable with Consistently Precise Control in Demanding Applications

More information

ACCELERATED CORROSION TEST CHAMBERS

ACCELERATED CORROSION TEST CHAMBERS ACCELERATED CORROSION TEST CHAMBERS SALT SPRAY CYCLIC ACCT CCT CASS IMMERSION TANK SATURATED HUMIDITY KESTERNICH-SO 2 UV PROHESION GRAVELOMETER www.equilamna.com SALT SPRAY Industries Served: : Paint,

More information

Refrigerated incubator with Peltier technology

Refrigerated incubator with Peltier technology KT series 53 Incubators and cooling incubators Refrigerated incubator with Peltier technology The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness.

More information

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER 30GX-4SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1997 Carrier Corporation Syracuse, New York 13221 Form 30GX-4SB Supersedes 30GX-3SB Printed in U.S.A. 12-97 Catalog

More information