1 NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) TRANSMISSION DIRECTORATE (A component of Power Transmission and Distribution Efficiency Enhancement Project BIDDING DOCUMENT FOR Procurement of Plant for Gas Insulated 220 kv Barhabise Substation (Design, Supply, Install and Commission) Single-Stage, Two-Envelope Bidding Procedure Issued on:. Invitation for Bids No.: ICB-TD-TKTLP 073/74-02 ICB No.: ICB-TD-TKTLP 073/74-02 Employer: Nepal Electricity Authority Country: Nepal VOLUME III OF III May 2017 Tamakoshi-Kathmandu 220/400 kv Transmission Line Project Transmission Directorate, NEA Training Center Complex Kharipati, Bhaktapur, Nepal Telephone: Fax: Contract.

2 SCHEDULE - 1 PAGE 1 OF 12 NEPAL ELECTRICITY AUTHORITY TRANSMISSION DIRECTORATE Tamakoshi-Kathmandu 220/400 kv Transmission Line Project IFB No. : ICB-TD-TKTLP-073/74-02: Design, Supply, Installation and Commissioning of Gas Insulated 220 kv Barhabise Substation Schedule No.1: Plant and Equipment including Mandatory Spares to be supplied from abroad : Foreign Currency LC: Local Currency Item No. Item description Country of origin Estimated (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity LC Currency# Rate Amount = (7) x (4) 9=8 10 I 220/132/11 kv GIS Barhabise Substation PART - A: OWNER ASSESSED QUANTITIES A POWER TRANSFORMER a) 53.33MVA, 220/ 3 / 132// 3 kv Single Phase Power Transformer (without transformer Oil) 4 Nos. b) Insulating oil for the above Power Transformer 4 Lot c) 33kV Current transformer (NCT) for autotrasnformer 1 No d) Oil Storage tank of 20KL 2 Nos. B POWER TRANSFORMER a) 5 MVA, 132 /11 kv Three Phase Power Transformer (without transformer Oil) 1 Nos. b) Insulating oil for the above Power Transformer 1 Lot C) LT Transformer a) 630KVA 11/0.400 Kv 2 Nos. D 245 KV EQUIPMENTS D1 245KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project 2 Sets kV, SF6 GIS Bus Coupler feeder bay Module as per section project 1 Sets kV, SF6 GIS Line feeder bay Module as per section project 4 Sets kV, SF6 GIS spare Line feeder bay Module as per section project 2 Sets kV, SF6 GIS ICT feeder bay Module as per section project 1 Sets 1.6 SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall alongwith associated support structure and accessories a) OPTION-I CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal)

3 SCHEDULE - 1 PAGE 2 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity 1600A, 40kA for 1 sec. Single Phase 240 Mtr. OPTION-II 1600A, 40kA, 1sec three phase 80 Mtr. Note : Bidder is required to quote for either option-i or Option-II b) 1600A, 40kA for 1 sec. Single Phase ( for 4X53.33 MVA 1 ph Transformer) 60 mtr kV, SF6 to Air Bushing alongwith associated support structure Currency# Rate Amount LC a) 1600A, 40kA for 1 sec. Single Phase 16 Nos kV, SF6 GIS Auxiliary Bus Module as per section project to connect spare unit of Transformer 1 set D.2 245KV Outdoor Equipment KV Surge Arrester (1-phase) 16 Nos pF, 245 kv Capacitive Voltage Transformer (1-Phase) 12 Nos kV Bus Post Insulator (1-Phase) (Except for wave trap) 12 Nos. E 145kV Equipment E.1 145KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project 2 Sets kV, SF6 GIS Bus Coupler feeder bay Module as per section project 1 Set kV, SF6 GIS Line feeder bay Module as per section project 2 Sets kV, SF6 GIS Spare Line feeder bay Module as per section project 1 Sets kV, SF6 GIS ICT feeder bay Module as per section project for 220/132 kv Transformer 1 Sets kV, SF6 GIS ICT feeder bay Module as per section project for 132/11 kv Transformer 1 Sets 1.7 SF6 Gas Insulated Bus Duct (GIB) outside GIS hall including Bus Duct support structure and associated accessories a) 1250A, 31.5kA, 1sec three phase 50 Mtr b 1250A, 31.5 ka 1sec single phase (for 4x53.33MVA 1-Phase Transformer bays) 30 Mtr kV, SF6 to Air Bushing alongwith associated support structure a) 1250A, 31.5kA, 1sec single phase 13 Set kV, SF6 GIS Auxiliary Bus Module as per section project to 1 set connect spare unit of Transformer

4 SCHEDULE - 1 PAGE 3 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity E.2 145kV EQUIPMENT(AIS) kv Surge Arrestors (1-Phase) 13 Nos pF, 145 kv Capacitive Voltage Transformer (1-Phase) 6 Nos KV Bus Post Insulator 6 Nos. Currency# Rate Amount LC F 11 KV EQUIPMENT kv Isolator (3-phase)-HDB i 400A, 25kA for 3 sec, Isolator without E/s (Beam Mounted) 2 Set kv Surge Arrester (1 ph.) 6 Nos kv Horn Gap fuse (1 ph.) 6 Nos kV BPI 6 Nos G 11kV, 25 ka (3 Phase) Indoor switch gear panel i) 11kV Transformer Module 1 Nos ii) 11kV LT Transformer Module 1 Nos iii) Bus PT Module 1 Nos H Testing & Maintenance Equipment for GIS 1.1 SF6 Gas processing 1 Set 1.2 Partial Discharge Monitoring System 1 Set 1.3 Dew Point Meter 1 Set 1.4 SF6 Gas Leak Detector 1 Set 1.5 Portable Ladder with adustable height as per TS 1 Nos. 1.6 EOT crane for 220kV GIS Hall 1 Set 1.7 EOT crane for 132kV GIS Hall 1 Set I RELAY PANELS (WITH AUTOMATION) 1 245kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose 6 Nos. b) CB Relay Panel Without Auto Reclose 2 Nos. 1.2 Line Protection Panel 6 Nos. 1.3 Transformer Protection Panel (For both HV & MV side) 1 Nos. 1.4 Bus Bar Protection Panel 1 set 2 145kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose 3 Nos. b) CB Relay Panel Without Auto Reclose 3 Nos. 1.2 Line Protection Panel 3 Nos.

5 SCHEDULE - 1 PAGE 4 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity 1.3 Transformer Protection Panel (For both HV & MV side) 1 Nos. 1.4 Bus Bar Protection Panel 1 set 3 Other/Common equipments Pertaining to C & R System a) Time Synchronisation Equipment 1 No. a) Relay Test kit 1 No. Currency# Rate Amount LC J SUBSTATION AUTOMATION 1 Substation Automation System as per Technical Specification: a) 220kV System 8 Nos. b) 132 kv System 6 Nos. c) BCU for auxilary system 1 set d) 11 kv HT Indoor Switchgear 1 set K Digital Protection Coupler, PBAX & Wave Trap a Digital Protection Coupler 16 Nos b PBAX with following configuration as per TS 1 Set i 2 wire subscriber interface card with capacity 32 local subscribers (along with 32 nos. Instruments) ii 4 wire E & M interface card with capacity 8 nos. trunks (For PLCC) iii) E-1 interface with 2 trunks G-703 iv) 2 wire interface with 1 trunk (For PSTN) c) Line Trap i) 1250A,0.5mH,31.5kA(132 kv) 2 nos ii) Bus Post Insulator for above 132 kv Wave Trap 6 no. L LT Switchgear (As per Technical specification) a 400V Main switchboard 1 Set b 400V ACDB 1 Set c 400V MLDB 1 Set d 400V Emergency LDB 1 Set e 220V DCDB 2 Sets g 48V DCDB 2 Set M a b Batteries 220V i 600 AH 2 Nos 48V

6 SCHEDULE - 1 PAGE 5 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity i 600AH 2 Nos Currency# Rate Amount LC N a b Float Cum Boost Battery Charger 220V Float Cum Boost Battery Charger i 90A/90A 2 Nos 48V Float Cum Boost Battery Charger i 90A/90A 2 Nos O Diesel Generator with control Panel a 250 kva 1 Set P a Fire Protection System Portable /Trolley/Wheel mounted extinguishers i 9 litre water type 2 Nos ii 50 litre foam type 2 Nos iii 4.5 kg CO 2 type 6 Nos iv 4.5 kg Dry Chemical Power (DCP) type 2 Nos b Smoke detection system 1 Set c Fire detection and Alarm System 1 Set Q a b R 1 Cables along with clamps, glands, lugs and straight joints etc. 11kV HT Cable alongwith accessories and termination equipments Power Cables - (1.1kV grade) i 3.5Cx300 sqmm (XLPE) cable for filter Machine along with 2 nos outdoor receptacles -250A Air conditioning High wall type split AC unit of 2 TR capacities for control room, relay room and battery room 2.5 KM 1 KM 25 Nos. S STEEL STRUCTURES (Tower,Gantry structures& Equipment support structures) a Lattice/pipe Structure for towers,beams and equipments including peak plates/pack washers and guest paltes including foundation bolts(nuts,washers,ms plate welded at the bottom) i) Lattice stucture & foundation bolts 100 MT

7 SCHEDULE - 1 PAGE 6 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity ii Pipe structure & foundation bolts 22 MT b Fastners for towers,beams and equipment support strcutures 5 MT Currency# Rate Amount LC T Communication Equipment 1 Transmission Equipment SDH Equipment ( STM- 4 MADM, upto 3 MSP protected A directions) Base Equipment (Common cards, Cross-connect/control cards, Optical base cards, Power supply cards, power cabling, other hardware & (I) accessories including sub-racks, patch cords, DDF etc. fully equipped excluding (II) and (III) below) 2 No. (II) Optical Interface/SFP # for a) S4.1 4 Nos. (a) L4.2 6 Nos. (III) Tributary Cards (a) E1 Interface card (Minimum 16 interfaces per card ) 2 Nos. (b) Ethernet interfaces 10/100 Mbps with Layer-2 switching (Minimum 4 interfaces per card.) 4 No. 2 Termination Equipment Drop/Insert Multiplexer A1 Base Equipment (Common cards, Power supply cards, power cabling, other hardware & accessories including sub-racks, etc. fully equipped 2 Nos. excluding subscriber line interface cards) A2 Subscriber Line Interface Cards a) 2 wire (sub/sub) voice channel cards (min 8 channels per card) 2 Nos. b) 4 wire (E&M) voice channel cards (min 8 channels per card) 2 Nos. c) Asynchronous Sub Channels data cards (minimum 4 channels per card) 2 No. d) Synchronous data card (NX64kbps) 2 Nos. 3 Equipment Cabinets a) For Drop/Insert Multiplexer 2 No. b) For SDH Equipment 2 No. 4 TMN Craft Terminal for SDH & PDH Equipments (a) Hardware 1 set (b) Software 1 set 5 Synchronization Equipment GPS clock including all hardware & accessories 1 set 6 Main Distribution Frame

8 SCHEDULE - 1 PAGE 7 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity 6 (100 pairs) 2 no 7.0 Test Equipment as per TS 1 set SUB TOTAL PART-A Currency# Rate Amount LC PART-B: VENDOR ASSESSED QUANTITIES Erection Hardware :-Insulator strings, Disc Insulators, Hardware, conductor, bus-bar materials, cable trays, clamps, spacers, connectors A including conectors for Auto Transformer, Junction box, earthwire, earthing material risers, buried cable trenches/pipe of equipment & lighting, all accessories etc. for the following: kv DM-type layout for GIS termination arrangement 1.1 Line Bay 4 Set 1.2 Transformer Bay 1 Sets kv DM-type layout for GIS termination arrangement 1.1 Line Bay 2 Sets 1.2 Transformer Bay 2 Sets 3 11 KV 2 SET Bus post insulators, Spacers, equipment support structures, B conductor(s), Al tube, clamp, connectors required for arrangement of Neutral formation for one transformer bank for making connection arrangement to connect spare unit in place of any other unit without physical shifting complete in all respect 1 Sets C Ventilation & heating System 2 Ventilation & heating system (as per technical specification) (i) 220kV GIS Hall 1 LS (ii) 132 kv GIS Hall 1 LS D Illumination System 1.1 Substation Lighting (i) Control Room cum administrative building illumination 1 LS (ii) 220kV GIS Building 1 LS (iii) 132kV GIS Building 1 LS IV. Indoor Switchyrad Panel Room 1 LS v Fire Fighting Room 1 LS vi Outdoor Switchyard Lighting 1 LS

9 SCHEDULE - 1 PAGE 8 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity vii Street Lighting 1 LS viii Occupancy sensor 1 LS 1.2 Township Area Lighting 1 LS Currency# Rate Amount LC E Fire Protection System per technical Specification) 1 Pumping arrangement inside pump house 1 set 2 Hydrant system outside the Pump House. 1 set 3 HVW spray system & Hydrant system for Transformer : a MVA, 220/132 kv Single Phase Auto Transformer 4 nos b 5 MVA,132/11 kv Three phase transformer 1 nos F POWER & CONTROL CABLES kv LV Cables 1.1 Power Cable(PVC insulated) 1 LS 1.2 Power Cable(XLPE insulated) 1 LS 1.3 Control Cable (PVC insulated) 1 LS 1.4 Cable glands, lugs & straight through joints for Power & Control cables 1 LS G Visual Monitoring System for watch & ward as per technical specification 1 LS H Earthing and lightning protection including necesaary connectors/connections, risers etc. complete in all respect i Earth Conductor (copper) 1 LS ii Earth Rod (copper clad steel) 1 LS iii Equipment for lightning protection 1 LS I a SUBSTATION AUTOMATION Integration of all 220/132kV Bays under present scope with the SCADA of SIEMENS (SINAUT Spectrum) at Load Dispatch Centre, Kathmandu including supply of Hardware, Software, accessories etc. as per TS Section Project. SUB TOTAL PART-B 1 LS PART-C: MANDATORY SPARES (Break up of Lumpsum quantity shall be as per Annexure-I, Section Project of Technical Specification).

10 SCHEDULE - 1 PAGE 9 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity I. Transformer(220/132 kv) 1 LS II Transformer(132//11 kv) 1 LS III. GIS(22O KV & 132 KV) 1 LS IV 220kV CVT 1 no V 132kV CVT 1 no VI 216kV LA 1 no VII 120kV LA 1 no VIII DG Set 1 LS IX Battery Charger 1 LS X Relay & Protection 1 LS XI Digital Protection Copler 1 LS XII Sub-Station Automation System 1 LS XIII LT Transformer 1 LS XIV Illumination System 1 LS XV Erection Hardware 1 LS XVI Telecommunication Equipments 1 LS XVII LT Indoor Switchgear 1 LS XVIII Fire Fighting 1 LS SUB-TOTAL PART-C Total for 220/132/11kV BARHABISE Substation (I) (Part-A+ Part- B+ Part C) Currency# Rate Amount LC II EXTENSION OF 220 KV KHIMTI S/S PART -A: OWNER ASSESSED QUANTITIES A 245 KV EQUIPMENTS A1 245KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project(extension) 2 Sets kV, SF6 GIS Line feeder bay Module as per section project 2 Sets kV, SF6 to Cable Bushing alongwith associated support structure a) 2000A, 40kA for 1 sec. Single Phase 6 Nos. A2 245KV Outdoor Equipment KV Surge Arrester (1-phase) 6 Nos pF, 245 kv Capacitive Voltage Transformer (1-Phase) 6 Nos kV Bus Post Insulator (1-Phase) (Except for wave trap) 12 Nos. B Testing & Maintenance Equipment for GIS

11 SCHEDULE - 1 PAGE 10 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity 1.1 SF6 Gas processing 1 Set 1.2 Partial Discharge Monitoring System 1 Set 1.3 Dew Point Meter 1 Set 1.4 SF6 Gas Leak Detector 1 Set Currency# Rate Amount LC C RELAY PANELS (WITH AUTOMATION) 1 245kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose 2 Nos. 1.2 Line Protection Panel 2 Nos. 1.3 Integration of existing Bus Bar Protection 1 set 3 Other/Common equipments Pertaining to C & R System a) Relay Test kit 1 No. D SUBSTATION AUTOMATION 1 Augmentation of Substation Automation System as per Technical Specification: a) 220kV System 2 Nos. E Cables along with clamps, glands, lugs and straight joints etc. a 220 kv grade 1 core, 1200sq.mm.XLPE insulated copper cable as per 1.5 KM technical specification b Cable end termination(s) on Gantry as per technical specification 6 nos F STEEL STRUCTURES (Tower,Gantry structures& Equipment support structures) a Lattice Structure for towers,beams and equipments including peak plates/pack washers and guest paltes including foundation 32 MT bolts(nuts,washers,ms plate welded at the bottom) b Fastners for towers,beams and equipment support strcutures 1 MT SUB TOTAL -PART-A PART-B: VENDOR ASSESSED QUANTITIES

12 SCHEDULE - 1 PAGE 11 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes Quantity Erection Hardware :-Insulator strings, Disc Insulators, Hardware, conductor, bus-bar materials, cable trays, clamps, spacers, connectors A including conectors for Auto Transformer, Junction box, earthwire, earthing material risers, buried cable trenches/pipe of equipment & lighting, all accessories etc. for the following: kv DM-type layout for GIS termination arrangement 1.1 Line Bay 2 Set Currency# Rate Amount LC B POWER & CONTROL CABLES kv LV Cables 1.1 Power Cable(PVC insulated) 1 LS 1.2 Control Cable (PVC insulated) 1 LS 1.3 Cable glands, lugs & straight through joints for Power & Control cables 1 LS C Earthing and lightning protection including necesaary connectors/connections, risers etc. complete in all respect SUB TOTAL PART-B 1 LS PART-C: MANDATORY SPARES (Break up of Lumpsum quantity shall be as per Annexure-I, Section Project of Technical Specification). I GIS 1 LS II 220kV CVT 1 no III 216kV LA 1 no IV Digital protecion Coupler 1 LS V Sub-Station Automation System 1 LS VI Illumination System 1 LS VII Erection Hardware 1 LS VIII Relay & Protection 1 LS TOTAL PART-C Total for 220kV KHIMTI Substation (II) (Part-A+ Part-B+ Part C) TOTAL (Total of (I) & (II) to be carried forward to Schedule No. 5: Grand Summary) Note : 1) Bidder is required to quote prices in this Schedule for all the individual items/sub-items. 2.) The Prices of equipments are inclusive of type test charges except for those mentioned in Schedule 4( e)

13 SCHEDULE - 1 PAGE 12 OF 12 Item No. Item description Country of origin Estimated CIP (site) including insurance, clearing, forwarding and transportation to site (Excluding Taxes and Duties applicable in Nepal) (Excluding Taxes and Duties) Custom, VAT and other taxes LC Quantity Currency# Rate Amount 3.) BOQ given above is indicative only based on the scope of work as given in Project Specific Requirements. The quantities mentioned above may undergo change during detailed engineering to meet the functional requirement and scope of work defined in Employer's Requirements. Name of Bidder: Signature of Bidder: (Printed Name) (Designation) (Common Seal) Date:

14 SCHEDULE - 2 PAGE 1 OF 11 NEPAL ELECTRICITY AUTHORITY TRANSMISSION DIRECTORATE Tamakoshi-Kathmandu 220/400 kv Transmission Line Project IFB No. : ICB-TD-TKTLP-073/74-02: Design, Supply, Installation and Commissioning of Gas Insulated 220 kv Barhabise Substation Schedule No. 2: Plant and Equipment including Mandatory Spares Parts to be supplied from within Nepal including Type Test Charges B POWER TRANSFORMER a) 5 MVA, 132 /11 kv Three Phase Power Transformer (without transformer Oil) 1 Nos. b) Insulating oil for the above Power Transformer 1 Lot C) LT Transformer a) 630KVA 11/0.400 Kv 2 Nos. D 245 KV EQUIPMENTS D1 245KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project 2 Sets kV, SF6 GIS Bus Coupler feeder bay Module as per section project 1 Sets kV, SF6 GIS Line feeder bay Module as per section project 4 Sets kV, SF6 GIS spare Line feeder bay Module as per section project kV, SF6 GIS ICT feeder bay Module as per section project 2 Sets 1 Sets 1.6 SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall alongwith associated support structure and accessories a) OPTION-I 1600A, 40kA for 1 sec. Single Phase 240 Mtr. All prices in local currency, NRs Ex Faxtory Price (Excluding VAT and other Inland Transportation up to Site Item No. Item Description Quantity VAT) (Excluding Taxes) taxes Rate Amount Rate Amount I 220/132/11 kv GIS Barhabise Substation PART - A: OWNER ASSESSED QUANTITIES A POWER TRANSFORMER a) 53.33MVA, 220/ 3 / 132// 3 kv Single Phase Power Transformer (without transformer Oil) 4 Nos. b) Insulating oil for the above Power Transformer 4 Lot c) 33kV Current transformer (NCT) for autotrasnformer 1 No d) Oil Storage tank of 20KL 2 Nos.

15 SCHEDULE - 2 PAGE 2 OF 11 Item No. Item Description Quantity OPTION-II 1600A, 40kA, 1sec three phase 80 Mtr. Note : Bidder is required to quote for either option-i or Option-II Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes b) 1600A, 40kA for 1 sec. Single Phase ( for 4X53.33 MVA 1 ph Transformer) 60 mtr kV, SF6 to Air Bushing alongwith associated support structure a) 1600A, 40kA for 1 sec. Single Phase 16 Nos kV, SF6 GIS Auxiliary Bus Module as per section project to connect spare unit of Transformer 1 set D.2 245KV Outdoor Equipment KV Surge Arrester (1-phase) 16 Nos pF, 245 kv Capacitive Voltage Transformer (1-Phase) 12 Nos kV Bus Post Insulator (1-Phase) (Except for wave trap) 12 Nos. E 145kV Equipment E.1 145KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project 2 Sets kV, SF6 GIS Bus Coupler feeder bay Module as per section project 1 Set kV, SF6 GIS Line feeder bay Module as per section project 2 Sets kV, SF6 GIS Spare Line feeder bay Module as per section project kV, SF6 GIS ICT feeder bay Module as per section project for 220/132 kv Transformer kV, SF6 GIS ICT feeder bay Module as per section project for 132/11 kv Transformer 1.7 SF6 Gas Insulated Bus Duct (GIB) outside GIS hall including Bus Duct support structure and associated accessories 1 Sets 1 Sets 1 Sets a) 1250A, 31.5kA, 1sec three phase 50 Mtr b 1250A, 31.5 ka 1sec single phase (for 4x53.33MVA 1-Phase Transformer bays) 30 Mtr kV, SF6 to Air Bushing alongwith associated support structure a) 1250A, 31.5kA, 1sec single phase 13 Set kV, SF6 GIS Auxiliary Bus Module as per section project to connect spare unit of Transformer 1 set

16 SCHEDULE - 2 PAGE 3 OF 11 Item No. Item Description Quantity E.2 145kV EQUIPMENT(AIS) kv Surge Arrestors (1-Phase) 13 Nos pF, 145 kv Capacitive Voltage Transformer (1-Phase) 6 Nos. Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes KV Bus Post Insulator 6 Nos. F 11 KV EQUIPMENT kv Isolator (3-phase)-HDB i 400A, 25kA for 3 sec, Isolator without E/s (Beam Mounted) 2 Set kv Surge Arrester (1 ph.) 6 Nos kv Horn Gap fuse (1 ph.) 6 Nos kV BPI 6 Nos G 11kV, 25 ka (3 Phase) Indoor switch gear panel i) 11kV Transformer Module 1 Nos ii) 11kV LT Transformer Module 1 Nos iii) Bus PT Module 1 Nos H Testing & Maintenance Equipment for GIS 1.1 SF6 Gas processing 1 Set 1.2 Partial Discharge Monitoring System 1 Set 1.3 Dew Point Meter 1 Set 1.4 SF6 Gas Leak Detector 1 Set 1.5 Portable Ladder with adustable height as per TS 1 Nos. 1.6 EOT crane for 220kV GIS Hall 1 Set 1.7 EOT crane for 132kV GIS Hall 1 Set I RELAY PANELS (WITH AUTOMATION) 1 245kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose 6 Nos. b) CB Relay Panel Without Auto Reclose 2 Nos. 1.2 Line Protection Panel 6 Nos. 1.3 Transformer Protection Panel (For both HV & MV side) 1 Nos. 1.4 Bus Bar Protection Panel 1 set 2 145kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose 3 Nos. b) CB Relay Panel Without Auto Reclose 3 Nos. 1.2 Line Protection Panel 3 Nos. 1.3 Transformer Protection Panel (For both HV & MV side) 1 Nos. 1.4 Bus Bar Protection Panel 1 set

17 SCHEDULE - 2 PAGE 4 OF 11 Item No. Item Description Quantity 3 Other/Common equipments Pertaining to C & R System a) Time Synchronisation Equipment 1 No. a) Relay Test kit 1 No. Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes J SUBSTATION AUTOMATION 1 Substation Automation System as per Technical Specification: a) 220kV System 8 Nos. b) 132 kv System 6 Nos. c) BCU for auxilary system 1 set d) 11 kv HT Indoor Switchgear 1 set K Digital Protection Coupler, PBAX & Wave Trap a Digital Protection Coupler 16 Nos b PBAX with following configuration as per TS 1 Set i 2 wire subscriber interface card with capacity 32 local subscribers (along with 32 nos. Instruments) ii 4 wire E & M interface card with capacity 8 nos. trunks (For PLCC) iii) E-1 interface with 2 trunks G-703 iv) 2 wire interface with 1 trunk (For PSTN) c) Line Trap i) 1250A,0.5mH,31.5kA(132 kv) 2 nos ii) Bus Post Insulator for above 132 kv Wave Trap 6 no. L LT Switchgear (As per Technical specification) a 400V Main switchboard 1 Set b 400V ACDB 1 Set c 400V MLDB 1 Set d 400V Emergency LDB 1 Set e 220V DCDB 2 Sets g 48V DCDB 2 Set M a b N a Batteries 220V i 600 AH 2 Nos 48V i 600AH 2 Nos Float Cum Boost Battery Charger 220V Float Cum Boost Battery Charger i 90A/90A 2 Nos

18 SCHEDULE - 2 PAGE 5 OF 11 Item No. Item Description b Quantity 48V Float Cum Boost Battery Charger i 90A/90A 2 Nos Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes O Diesel Generator with control Panel a 250 kva 1 Set P a Fire Protection System Portable /Trolley/Wheel mounted extinguishers i 9 litre water type 2 Nos ii 50 litre foam type 2 Nos iii 4.5 kg CO 2 type 6 Nos iv 4.5 kg Dry Chemical Power (DCP) type 2 Nos b Smoke detection system 1 Set c Fire detection and Alarm System 1 Set Q a b R 1 S a Cables along with clamps, glands, lugs and straight joints etc. 11kV HT Cable alongwith accessories and termination equipments Power Cables - (1.1kV grade) i 3.5Cx300 sqmm (XLPE) cable for filter Machine along with 2 nos outdoor receptacles -250A Air conditioning High wall type split AC unit of 2 TR capacities for control room, relay room and battery room STEEL STRUCTURES (Tower,Gantry structures& Equipment support structures) Lattice/pipe Structure for towers,beams and equipments including peak plates/pack washers and guest paltes including foundation bolts(nuts,washers,ms plate welded at the bottom) 2.5 KM 1 KM 25 Nos. i) Lattice stucture & foundation bolts 100 MT ii Pipe structure & foundation bolts 22 MT b Fastners for towers,beams and equipment support strcutures 5 MT T Communication Equipment 1 Transmission Equipment SDH Equipment ( STM- 4 MADM, upto 3 MSP protected A directions)

19 SCHEDULE - 2 PAGE 6 OF 11 Item No. Item Description Quantity Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes (I) Base Equipment (Common cards, Cross-connect/control cards, Optical base cards, Power supply cards, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding (II) and (III) below) 2 No. (II) Optical Interface/SFP # for a) S4.1 4 Nos. (a) L4.2 6 Nos. (III) Tributary Cards (a) E1 Interface card (Minimum 16 interfaces per card ) 2 Nos. (b) Ethernet interfaces 10/100 Mbps with Layer-2 switching (Minimum 4 interfaces per card.) 4 No. 2 Termination Equipment Drop/Insert Multiplexer A1 Base Equipment (Common cards, Power supply cards, power cabling, other hardware & accessories including sub-racks, etc. fully equipped excluding subscriber line interface cards) 2 Nos. A2 Subscriber Line Interface Cards a) 2 wire (sub/sub) voice channel cards (min 8 channels per card) 2 Nos. b) 4 wire (E&M) voice channel cards (min 8 channels per card) 2 Nos. c) Asynchronous Sub Channels data cards (minimum 4 channels per card) 2 No. d) Synchronous data card (NX64kbps) 2 Nos. 3 Equipment Cabinets a) For Drop/Insert Multiplexer 2 No. b) For SDH Equipment 2 No. 4 TMN Craft Terminal for SDH & PDH Equipments (a) Hardware 1 set (b) Software 1 set 5 Synchronization Equipment GPS clock including all hardware & accessories 1 set 6 Main Distribution Frame (100 pairs) 2 no 7.0 Test Equipment as per TS 1 set SUB TOTAL PART-A PART-B: VENDOR ASSESSED QUANTITIES

20 SCHEDULE - 2 PAGE 7 OF 11 Item No. Item Description A Erection Hardware :-Insulator strings, Disc Insulators, Hardware, conductor, bus-bar materials, cable trays, clamps, spacers, connectors including conectors for Auto Transformer, Junction box, earthwire, earthing material risers, buried cable trenches/pipe of equipment & lighting, all accessories etc. for the following: Quantity Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes kv DM-type layout for GIS termination arrangement 1.1 Line Bay 4 Set 1.2 Transformer Bay 1 Sets kv DM-type layout for GIS termination arrangement 1.1 Line Bay 2 Sets 1.2 Transformer Bay 2 Sets 3 11 KV 2 SET Bus post insulators, Spacers, equipment support structures, conductor(s), Al tube, clamp, connectors required for B arrangement of Neutral formation for one transformer bank for making connection arrangement to connect spare unit in place of any other unit without physical shifting complete in all respect 1 Sets C Ventilation & heating System 2 Ventilation & heating system (as per technical specification) (i) 220kV GIS Hall 1 LS (ii) 132 kv GIS Hall 1 LS D Illumination System 1.1 Substation Lighting (i) Control Room cum administrative building illumination 1 LS (ii) 220kV GIS Building 1 LS (iii) 132kV GIS Building 1 LS IV. Indoor Switchyrad Panel Room 1 LS v Fire Fighting Room 1 LS vi Outdoor Switchyard Lighting 1 LS vii Street Lighting 1 LS viii Occupancy sensor 1 LS 1.2 Township Area Lighting 1 LS

21 SCHEDULE - 2 PAGE 8 OF 11 Item No. Item Description Quantity E Fire Protection System per technical Specification) 1 Pumping arrangement inside pump house 1 set 2 Hydrant system outside the Pump House. 1 set 3 HVW spray system & Hydrant system for Transformer : a MVA, 220/132 kv Single Phase Auto Transformer 4 nos b 5 MVA,132/11 kv Three phase transformer 1 nos Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes F POWER & CONTROL CABLES kv LV Cables 1.1 Power Cable(PVC insulated) 1 LS 1.2 Power Cable(XLPE insulated) 1 LS 1.3 Control Cable (PVC insulated) 1 LS 1.4 Cable glands, lugs & straight through joints for Power & Control cables 1 LS G Visual Monitoring System for watch & ward as per technical specification 1 LS H Earthing and lightning protection including necesaary connectors/connections, risers etc. complete in all respect i Earth Conductor (copper) 1 LS ii Earth Rod (copper clad steel) 1 LS iii Equipment for lightning protection 1 LS I a SUBSTATION AUTOMATION Integration of all 220/132kV Bays under present scope with the SCADA of SIEMENS (SINAUT Spectrum) at Load Dispatch Centre, Kathmandu including supply of Hardware, Software, accessories etc. as per TS Section Project. 1 LS SUB TOTAL PART-B PART-C: MANDATORY SPARES (Break up of Lumpsum quantity shall be as per Annexure-I, Section Project of Technical Specification). I. Transformer(220/132 kv) 1 LS II Transformer(132//11 kv) 1 LS III. GIS(22O KV & 132 KV) 1 LS IV 220kV CVT 1 no V 132kV CVT 1 no VI 216kV LA 1 no VII 120kV LA 1 no

22 SCHEDULE - 2 PAGE 9 OF 11 Item No. Item Description Quantity VIII DG Set 1 LS IX Battery Charger 1 LS X Relay & Protection 1 LS XI Digital Protection Copler 1 LS XII Sub-Station Automation System 1 LS XIII LT Transformer 1 LS XIV Illumination System 1 LS XV Erection Hardware 1 LS XVI Telecommunication Equipments 1 LS XVII LT Indoor Switchgear 1 LS XVIII Fire Fighting 1 LS SUB-TOTAL-C Total for 220/132/11kV BARHABISE Substation (I) (Part- A+ Part-B+ Part C) Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes II EXTENSION OF 220 KV KHIMTI S/S PART -A: OWNER ASSESSED QUANTITIES A 245 KV EQUIPMENTS A1 245KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project(extension) kV, SF6 GIS Line feeder bay Module as per section project 2 Sets 2 Sets kV, SF6 to Cable Bushing alongwith associated support structure a) 2000A, 40kA for 1 sec. Single Phase 6 Nos. A2 245KV Outdoor Equipment KV Surge Arrester (1-phase) 6 Nos pF, 245 kv Capacitive Voltage Transformer (1-Phase) 6 Nos kV Bus Post Insulator (1-Phase) (Except for wave trap) 12 Nos. B Testing & Maintenance Equipment for GIS 1.1 SF6 Gas processing 1 Set 1.2 Partial Discharge Monitoring System 1 Set 1.3 Dew Point Meter 1 Set 1.4 SF6 Gas Leak Detector 1 Set C RELAY PANELS (WITH AUTOMATION) 1 245kV 1.1 Circuit Breaker Relay Panel

23 SCHEDULE - 2 PAGE 10 OF 11 Item No. Item Description Quantity a) CB Relay Panel With Auto Reclose 2 Nos. 1.2 Line Protection Panel 2 Nos. 1.3 Integration of existing Bus Bar Protection 1 set 3 Other/Common equipments Pertaining to C & R System a) Relay Test kit 1 No. Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes D SUBSTATION AUTOMATION 1 Augmentation of Substation Automation System as per Technical Specification: a) 220kV System 2 Nos. E Cables along with clamps, glands, lugs and straight joints etc. a 220 kv grade 1 core, 1200sq.mm.XLPE insulated copper cable as per technical specification b Cable end termination(s) on Gantry as per technical specification 1.5 KM 6 nos F a b STEEL STRUCTURES (Tower,Gantry structures& Equipment support structures) Lattice Structure for towers,beams and equipments including peak plates/pack washers and guest paltes including foundation bolts(nuts,washers,ms plate welded at the bottom) Fastners for towers,beams and equipment support strcutures SUB TOTAL -PART-A 32 MT 1 MT A PART-B: VENDOR ASSESSED QUANTITIES Erection Hardware :-Insulator strings, Disc Insulators, Hardware, conductor, bus-bar materials, cable trays, clamps, spacers, connectors including conectors for Auto Transformer, Junction box, earthwire, earthing material risers, buried cable trenches/pipe of equipment & lighting, all accessories etc. for the following: kv DM-type layout for GIS termination arrangement 1.1 Line Bay 2 Set B POWER & CONTROL CABLES kv LV Cables 1.1 Power Cable(PVC insulated) 1 LS

24 SCHEDULE - 2 PAGE 11 OF 11 Item No. Item Description Quantity 1.2 Control Cable (PVC insulated) 1 LS 1.3 Cable glands, lugs & straight through joints for Power & Control cables 1 LS Ex Faxtory Price (Excluding VAT) Inland Transportation up to Site Rate Amount Rate Amount (Excluding Taxes) VAT and other taxes C Earthing and lightning protection including necesaary connectors/connections, risers etc. complete in all respect SUB TOTAL PART-B 1 LS PART-C: MANDATORY SPARES (Break up of Lumpsum quantity shall be as per Annexure-I, Section Project of Technical Specification). I GIS 1 LS II 220kV CVT 1 no III 216kV LA 1 no IV Digital protecion Coupler 1 LS V Sub-Station Automation System 1 LS VI Illumination System 1 LS VII Erection Hardware 1 LS VIII Relay & Protection 1 LS TOTAL PART-C Total for 220kV KHIMTI Substation (II) (Part-A+ Part-B+ Part C) Total Ex-works Price ( Total of (I) and (II) to be carried forward to Schedule No. 5A: Grand Summary) Note : 1) Bidder is required to quote prices in this Schedule for all the individual items/sub-items. 2.) The Prices of equipments are inclusive of type test charges except for those mentioned in Schedule 4( e) 3.) BOQ given above is indicative only based on the scope of work as given in Project Specific Requirements. The quantities mentioned above may undergo change during detailed engineering to meet the functional requirement and scope of work defined in Employer's Requirements. Name of Bidder: Signature of Bidder: (Printed Name) (Designation) (Common Seal) Date:

25 SCHEDULE - 3 PAGE 1 OF 1 NEPAL ELECTRICITY AUTHORITY TRANSMISSION DIRECTORATE Tamakoshi-Kathmandu 220/400 kv Transmission Line Project IFB No. : ICB-TD-TKTLP-073/74-02: Design, Supply, Installation and Commissioning of Gas Insulated 220 kv Barhabise Substation Schedule A-3: Design Services : NOT APPLICABLE Item No. Item Description Estimated Local Currency portion Prices Foreign Currency Portion Total Prices Quantity NRs Currency LC =3x5 8=3x6 1 NOT APPLICABLE Name of Bidder: Date: Signature of Bidder: (Printed Name) (Designation) (Common Seal)

26 SCHEDULE - 4 (a) PAGE 1 OF 12 Schedule No. 4: Installation Services (a): Installation and Construction Charges NEPAL ELECTRICITY AUTHORITY TRANSMISSION DIRECTORATE Tamakoshi-Kathmandu 220/400 kv Transmission Line Project IFB No. : ICB-TD-TKTLP-073/74-02: Design, Supply, Installation and Commissioning of Gas Insulated 220 kv Barhabise Substation Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges (1) (2) (3) (4) (5) (6) (7)=(4)X6) (8) (9)=(4)X(8) I 220/132/11kV GIS BARHABISE Substation PART - A: OWNER ASSESSED QUANTITIES A POWER TRANSFORMER a) 53.33MVA, 220/ 3 / 132// 3 kv Single Phase Power Transformer (without transformer Oil) Nos. 4 b) Insulating oil for the above Power Transformer Lot 4 c) 33kV Current transformer (NCT) for autotrasnformer No 1 d) Oil Storage tank of 20KL Nos. 2 B POWER TRANSFORMER a) 5 MVA, 132 /11 kv Three Phase Power Transformer (without transformer Oil) Nos. 1 b) Insulating oil for the above Power Transformer Lot 1 C) LT Transformer a) 630KVA 11/0.400 Kv Nos. 2 D 245 KV EQUIPMENTS D1 245KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project Sets kV, SF6 GIS Bus Coupler feeder bay Module as per section project Sets kV, SF6 GIS Line feeder bay Module as per section project Sets kV, SF6 GIS spare Line feeder bay Module as per section project Sets kV, SF6 GIS ICT feeder bay Module as per section project Sets SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall alongwith associated support structure and accessories a) SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall alongwith associated support structure and accessories OPTION-I Mtr A, 40kA for 1 sec. Single Phase OPTION-II Mtr A, 40kA, 1sec three phase Note : Bidder is required to quote for either option-i or Option-II b 1600A, 40kA for 1 sec. Single Phase ( for 4X53.33 MVA 1 ph Transformer) mtr 60

27 SCHEDULE - 4 (a) PAGE 2 OF 12 Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges kV, SF6 to Air Bushing alongwith associated support structure Nos kV, SF6 GIS Auxiliary Bus Module as per section project to connect spare unit of Transformer set 1 D A, 40kA for 1 sec. Single Phase KV Surge Arrester (1-phase) Nos pF, 245 kv Capacitive Voltage Transformer (1-Phase) Nos kV Bus Post Insulator (1-Phase) (Except for wave trap) Nos. 12 E 145kV Equipment E.1 145KV GIS Equipment kV, SF6 GIS Bus Bars Module as per section project Sets kV, SF6 GIS Bus Coupler feeder bay Module as per section project Set kV, SF6 GIS Line feeder bay Module as per section project Sets kV, SF6 GIS Spare Line feeder bay Module as per section project Sets kV, SF6 GIS ICT feeder bay Module as per section project for 220/132 kv Transformer Sets kV, SF6 GIS ICT feeder bay Module as per section project for 132/11 kv Transformer Sets SF6 Gas Insulated Bus Duct (GIB) outside GIS hall including Bus Duct support structure and associated accessories a) 1250A, 31.5kA, 1sec three phase Mtr 50 b 1250A, 31.5 ka 1sec single phase (for 4x53.33MVA 1-Phase Transformer bays) mtr kV, SF6 to Air Bushing alongwith associated support structure a) 1250A, 31.5kA, 1sec single phase Set kV, SF6 GIS Auxiliary Bus Module as per section project to connect spare unit of Transformer set 1 E.2 145kV EQUIPMENT(AIS) kv Surge Arrestors (1-Phase) Nos pF, 145 kv Capacitive Voltage Transformer (1-Phase) Nos KV Bus Post Insulator Nos. 6 F 11 KV EQUIPMENT kv Isolator (3-phase)-HDB i 400A, 25kA for 3 sec, Isolator without E/s (Beam Mounted) Set kv Surge Arrester (1 ph.) Nos kv Horn Gap fuse (1 ph.) Nos kV BPI Nos 6 G 11kV, 25 ka (3 Phase) Indoor switch gear panel i) 11kV Transformer Module Nos 1 ii) 11kV LT Transformer Module Nos 1 iii) Bus PT Module No 1 H Testing & Maintenance Equipment for GIS

28 SCHEDULE - 4 (a) PAGE 3 OF 12 Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges 1.6 EOT crane for 220kV GIS Hall Set EOT crane for 132kV GIS Hall Set 1 I RELAY PANELS (WITH AUTOMATION) 1 245kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose Nos Line Protection Panel Nos Transformer Protection Panel (For both HV & MV side) Nos Bus Bar Protection Panel set kV 1.1 Circuit Breaker Relay Panel a) CB Relay Panel With Auto Reclose Nos. 3 b) CB Relay Panel Without Auto Reclose Nos Line Protection Panel Nos Transformer Protection Panel (For both HV & MV side) Nos Bus Bar Protection Panel set 1 3 Other/Common equipments Pertaining to C & R System a) Time Synchronisation Equipment No. 1 J SUBSTATION AUTOMATION 1 Substation Automation System as per Technical Specification: a) 220kV System Nos. 8 b) 132 kv System Nos. 6 c) BCU for auxilary system set 1 d) 11 kv HT Indoor Switchgear set 1 K Digital Protection Coupler, PBAX & Wave Trap a) Digital Protection Coupler Nos 16 b) PBAX with following configuration as per TS Set 1 i 2 wire subscriber interface card with capacity 32 local subscribers (along with 32 nos. Instruments) ii 4 wire E & M interface card with capacity 8 nos. trunks (For PLCC) iii) E-1 interface with 2 trunks G-703 iv) 2 wire interface with 1 trunk (For PSTN) c) Line Trap i) 1250A,0.5mH,31.5kA(132 kv) nos 2 ii) Bus Post Insulator for above 132 kv Wave Trap no. 6 L LT Switchgear (As per Technical specification) a 400V Main switchboard Set 1 b 400V ACDB Set 1 c 400V MLDB Set 1 d 400V Emergency LDB Set 1

29 SCHEDULE - 4 (a) PAGE 4 OF 12 Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges e 220V DCDB Sets 2 g 48V DCDB Set 2 M Batteries a 220V i 600 AH Nos 2 b 48V i 600AH Nos 2 N Float Cum Boost Battery Charger a 220V Float Cum Boost Battery Charger i 90A/90A Nos 2 b 48V Float Cum Boost Battery Charger i 90A/90A Nos 2 O Diesel Generator with control Panel a 250 kva Set 1 P Fire Protection System a Portable /Trolley/Wheel mounted extinguishers i 9 litre water type Nos 2 ii 50 litre foam type Nos 2 iv 4.5 kg Dry Chemical Power (DCP) type Nos 2 b Smoke detection system Set 1 c Fire detection and Alarm System Set 1 Q i R 1 Cables along with clamps, glands, lugs and straight joints etc. 3.5Cx300 sqmm (XLPE) cable for filter Machine along with 2 nos outdoor receptacles -250A Air conditioning High wall type split AC unit of 2 TR capacities for control room, relay room and battery room KM 1 Nos. 25 S STEEL STRUCTURES (Tower,Gantry structures& Equipment support structures) a Lattice/pipe Structure for towers,beams and equipments including peak plates/pack washers and guest paltes including foundation bolts(nuts,washers,ms plate welded at the bottom) i) Lattice stucture & foundation bolts MT 100 ii Pipe structure & foundation bolts MT 22 b Fastners for towers,beams and equipment support strcutures MT 5 T Communication Equipment

30 SCHEDULE - 4 (a) PAGE 5 OF 12 Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges 1 Transmission Equipment A SDH Equipment ( STM- 4 MADM, upto 3 MSP protected directions) (I) Base Equipment (Common cards, Cross-connect/control cards, Optical base cards, Power supply cards, power cabling, other hardware & accessories including subracks, patch cords, DDF etc. fully equipped excluding (II) and (III) below) No. 2 (II) Optical Interface/SFP # for a) S4.1 Nos. 4 (a) L4.2 Nos. 6 (III) Tributary Cards (a) E1 Interface card (Minimum 16 interfaces per card ) Nos. 2 (b) Ethernet interfaces 10/100 Mbps with Layer-2 switching (Minimum 4 interfaces per card.) No. 4 2 Termination Equipment A1 Drop/Insert Multiplexer Base Equipment (Common cards, Power supply cards, power cabling, other hardware A2 & accessories including sub-racks, etc. fully equipped excluding subscriber line Subscriber Line Interface Cards Nos. 2 b) 4 wire (E&M) voice channel cards (min 8 channels per card) Nos. 2 c) Asynchronous Sub Channels data cards (minimum 4 channels per card) No. 2 d) Synchronous data card (NX64kbps) Nos. 2 3 Equipment Cabinets a) For Drop/Insert Multiplexer No. 2 b) For SDH Equipment No. 2 (a) Hardware set 1 (b) Software set 1 5 Synchronization Equipment GPS clock including all hardware & accessories set 1 6 Main Distribution Frame (100 pairs) no Test Equipment as per TS set 1 SUB TOTAL PART-A PART-B: VENDOR ASSESSED QUANTITIES A Erection Hardware :-Insulator strings, Disc Insulators, Hardware, conductor, bus-bar materials, cable trays, clamps, spacers, connectors including conectors for Auto Transformer, Junction box, earthwire, earthing material risers, buried cable trenches/pipe of equipment & lighting, all accessories etc. for the following: kv DM-type layout for GIS termination arrangement 1.1 Line Bay Set Transformer Bay Sets kv DM-type layout for GIS termination arrangement 1.1 Line Bay Sets 2

31 SCHEDULE - 4 (a) PAGE 6 OF 12 Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges 3 11 KV SET 2 B Bus post insulators, Spacers, equipment support structures, conductor(s), Al tube, clamp, connectors required for arrangement of Neutral formation for one transformer bank for making connection arrangement to connect spare unit in place of any other unit without physical shifting complete in all respect Sets 1 C Ventilation & heating System (ii) 132 kv GIS Hall LS 1 D Illumination System 1.1 Substation Lighting (iii) 132kV GIS Building LS 1 IV. Indoor Switchyrad Panel Room LS 1 v Fire Fighting Room LS 1 vi Outdoor Switchyard Lighting LS 1 vii Street Lighting LS 1 E Fire Protection System per technical Specification) set 1 1 Pumping arrangement inside pump house set 1 2 Hydrant system outside the Pump House. set 1 3 HVW spray system & Hydrant system for Transformer : b 5 MVA,132/11 kv Three phase transformer nos 1 F POWER & CONTROL CABLES kv LV Cables 1.1 Power Cable(PVC insulated) LS Power Cable(XLPE insulated) LS Control Cable (PVC insulated) LS Cable glands, lugs & straight through joints for Power & Control cables LS 1 G Visual Monitoring System for watch & ward as per technical specification LS 1 H Earthing and lightning protection including necesaary connectors/connections, risers etc. complete in all respect i Earth Conductor (copper) LS 1 ii Earth Rod (copper clad steel) LS 1 iii Equipment for lightning protection LS 1 I SUBSTATION AUTOMATION a Integration of all 220/132kV Bays under present scope with the SCADA of SIEMENS (SINAUT Spectrum) at Load Dispatch Centre, Kathmandu including supply of Hardware, Software, accessories etc. as per TS Section Project. LS 1 SUB TOTAL PART-B

32 SCHEDULE - 4 (a) PAGE 7 OF 12 Sl. No. Item Description Qty. Portion in Foreign Currency Installation Charges Portion in Nepaln Currency (in NRs) Currency* Rate Total Charges Rate Total Charges PART-C: Civil Works 1.0 Excavation in all types of soil and rock including backfilling disposal etc. for all leads and lifts Cu.M 16, Providing and laying of Plain Cement Concrete (PCC) (1:4:8) Cu.M Providing and laying of Plain Cement Concrete (PCC) (1:2:4) Cu.M Providing and laying of Reinforced Cement Concrete Design Mix M25 including pre cast, shuttering, Grouting of pockets & underpinning but excluding steel Cu.M 4710 reinforcement Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 Stone 5.0 Cu.M 600 aggregate) 6.0 Steel Reinforcement ( Fe 500) MT Stone filling (40 mm size) over grating of transformer/ reactor foundation Cu.M Misc. Structural steel including rails, embedments, edge protection angles, gratings MT Stone spreading including antiweed treatment in switchyard excluding PCC Sq. M All civil works for following buildings as per technical specification and approved i) Auxilliary building (11kV indoor panel) Sq. M. 125 ii) Fire fighting pump house building (excluding external finish) Sq. M. 98 iii) Water Tank (excluding external finish) LS 1 v) Township (Quarters) (a) B Type Sq. M. 500 (b) C Type Sq. M. 600 (c) D Type Sq. M. 210 vi) Transit Camp Sq. M. 420 vii) Parking Shed (for 10 Cars) LS External finish as per specification for following buildings: i) Auxilliary building (11kV indoor panel) Sq. M. 125 ii) Fire fighting pump house building (excluding external finish) Sq. M. 98 iii) Water Tank (excluding external finish) LS 1 v) Township (Quarters) (a) B Type Sq. M. 500 (b) C Type Sq. M. 600 (c) D Type Sq. M. 210 vi) Transit Camp Sq. M. 420 vii) Parking Shed (for 10 Cars) LS PRE ENGINEERED BUILDINGS i) CONTROL ROOM BULIDING All Civil works including finishing, internal cable trench, etc. complete as per ii) technical 220 KV GIS specification HALL and approved drawings, excluding excavation, PCC, RCC and All Civil works including finishing, internal cable trench, etc. complete as per iii) technical 132 KV GIS specification HALL and approved drawings, excluding excavation, PCC, RCC and All Civil works including finishing, internal cable trench, etc. complete as per technical specification and approved drawings, excluding excavation, PCC, RCC and 13.0 Concrete road as per drawing except reinforcement & concrete Sq. M. 750 Sq. M. 600 Sq. M. 500

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate LAPSIPHEDI & CHANGUNARAYAN SUBSTATION CONSTRUCTION PROJECT (A Component of Power Transmission and Distribution

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal)

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) TRANSMISSION DIRECTORATE HETAUDA-DHALKEBAR-INARUWA 400KV SUBSTATION EXPANSION PROJECT BIDDING DOCUMENT FOR Procurement of Plant Design,

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate MARSYANGDI CORRIDOR 220 KV TRANSMISSION LINE PROJECT BIDDING DOCUMENT FOR Procurement of Plant Design,

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate (An Undertaking of Government of Nepal) Project Management Directorate KATHMANDU VALLEY EAST AND SOUTH DISTRIBUTION SYSTEM ENHANCEMENT PROJECT (A Component of ) BIDDING DOCUMENT FOR Enhancement of Distribution

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate (An Undertaking of Government of Nepal) Project Management Directorate KATHMANDU VALLEY EAST AND SOUTH DISTRIBUTION SYSTEM ENHANCEMENT PROJECT (A Component of ) BIDDING DOCUMENT FOR Enhancement of Distribution

More information

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Schedules 1 to 4, Lot B: Extension of the Lessos Substation 1.0 LIGHTNING ARRESTORS 1.1 ZNO lightning arrester, 192 kv rated voltage, 10 ka nominal discharge current 2.0 CAPACITIVE VOLTAGE TRANSFORMER ea. 45 2.1 220 kv capacitive voltage transformer 220/ 3 / 0.11/

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Design,Engineering, manufacturing, supply, erection, testing & commissioning of 66

More information

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID S.NO. HEAD DESCRIPTION AMOUNT (Rs.) 1 A DG SETS & ACCESSORIES

More information

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M ORISSA POWER TRANSMISSION CORPORATION LIMITED Supply & Laying of 132 KV XLPE Double Circuit (4 cable per Circuit including one spare) underground 1000 Sq. mm annealed Copper XLPE EHV Cable with Associated

More information

TENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP

TENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP TENDER SPECIFICATION BHEL: PSSR: SCT: 1336 FOR Handling at Site Stores / Storage yard, Transportation to Site of Work, Erection, Testing and Commissioning of HT and LT Electrical Package for Unit 5-1x

More information

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR AN ISO 9001 & 14001 COMPANY TENDER DOCUMENT TENDER No: DLI/CON/696/411 FOR SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 11/0.433KV INDOOR/OUTDOOR ELECTRIC SUBSTATION AND OTHER ASSOCIATED EXTERNAL ELECTRICAL

More information

SCHEDULE OF QUANTITIES ITEM DESCRIPTION

SCHEDULE OF QUANTITIES ITEM DESCRIPTION SCHEDULE OF QUANTITIES ITEM DESCRIPTION A. SUBSTATION EQUIPMENT Suplly, installation, Testing and Commissiong of kv, 350 MVA ( 8.4 ka ), 630A, HT Panel Vacuum circuit breaker Switchboard, cubicle type,

More information

PRICE BID - PART: I I

PRICE BID - PART: I I T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/PLT-ELE/603 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR TENDER DOCUMENT (TENDER No: ) FOR BALANCE WORK OF SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF TWO NO. 11/0.433KV INDOOR ELECTRIC SUBSTATION (ESS-1 & 2), THREE NO. OUTDOOR TYPE 11/0.433KV COMPACT SUB-STATION

More information

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) Generation Directorate Medium Generation Operation and Maintenance Department SUNDARIJAL HYDROPOWER PLANT REHABILITATION PROJECT Electricity

More information

S P E C I F I C A T I O N

S P E C I F I C A T I O N T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/KKT-ELE/627 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY Phone: +91 431 257 79 38 Fax

More information

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 THE SOUTH AFRICAN INSTITUTE OF ELECTRICAL ENGINEERS FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 OVERVIEW : 1. Introduction to Distribution, Transmission and Generation

More information

Max value Max life Range from. ($000) (Years) Pole Type

Max value Max life Range from. ($000) (Years) Pole Type Draft Handbook Vector Asset Description 1 Unit Maximum Maximum Life Max value Max life Max Asset Life Max Asset Life Range from Submitters Max Asset Life ($000) SUBTRANSMISSION Concrete Wood Concrete Wood

More information

S P E C I F I C A T I O N

S P E C I F I C A T I O N T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/BHT-ELE/647 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

TENDER DOCUMENT PART-II

TENDER DOCUMENT PART-II 1 NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT TAMILNADU REGIONAL OFFICE TENDER DOCUMENT PART-II (PRICE BID) Supply, Installation, Testing and Commissioning of 25 kva DG Sets with Acoustic Enclosure

More information

Blank Price bid (Bill of Quantity) for Part B contract

Blank Price bid (Bill of Quantity) for Part B contract Blank Price bid (Bill of Quantity) for Part B contract First Year Second Year Third Year Sr.No Job Description UOM Qty per annum Unit rate Total Amount Qty per annum Unit rate Total Amount Qty per annum

More information

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read Tender for procurement of Passive Components of LAN & Wi-Fi and their installation Corrigenda Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 1. Annexure-I, Point No. 1.3 24 Port

More information

Set /

Set / BOQ and estimated Cost of Smart City Project, DHBVN, Gurgaon(prepared by DHBVN) Sr. NO. Description Unit Qty. Unit Supply Rate ref Total Supply cost Unit Erection Cost Total Erection Total Cost Rates Cost

More information

S P E C I F I C A T I O NS

S P E C I F I C A T I O NS FOR OFFICIAL USE ONLY T FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O NS TENDER. BHEL/NR/SCT/ GGSRP BATHINDA / ELE / 659 FOR Erection, testing, commissioning, post commissioning,

More information

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows: This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows: I. ADDENDUM Isinya Mandatory Spares list Description Quantity A AIS 400kV

More information

Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram:

Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram: Question Set(2017) Switch Gear & protection(5 th SEm) 1. What is fault in power system? Classify the fault. What are the bad effects of fault? 2. Define with example: Symmetrical fault and unsymmetrical

More information

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR OFFICIAL USE ONLY NOT FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR ERECTION, TESTING, COMMISSIONING TRIAL OPERATION

More information

SCHEDULE OF QUANTITY

SCHEDULE OF QUANTITY SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

२१७१ २-१ ४४ २०१८ २-१ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ १ २ ३ २ ३ १३ २०१८-१९

२१७१ २-१ ४४ २०१८ २-१ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ १ २ ३ २ ३ १३ २०१८-१९ २१७१ २-१ ४४ २०१८ २ :- (०७१७२)२२७३८२-४४२४०३ - (०७१७२)२२७३८२ - mlidn2@rediffmail.com ३१ / १२ २०१८ - - १ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ ------000-----

More information

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016 No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date: 10111. 4711M1 An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY Corrigendum 1

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the

More information

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole 1 L.T Stay set Complete Set 5 2 7/12 GI stay wire kg 50 3 Concreting of stay NO 5 4 Stay clamp

More information

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI-781001 DETAILED QUOTATION NOTICE & DOCUMENTS NAME OF WORK:- Annual quotation for supply of spare parts for machineries for the year 2017-2018.

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description

More information

Appendix 11 RETURN TO APPENDICES LIST. High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd)

Appendix 11 RETURN TO APPENDICES LIST. High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd) Appendix 11 RETURN TO APPENDICES LIST High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd) GLADSTONE AREA WATERBOARD AWOONGA DAM HIGH VOLTAGE POWER SUPPLY UPGRADE Document: GJ543-RP-02B Submission

More information

3) The water conductor system consisting of RCC, partly cut and cover, conduit of size 10.5m x 7m and m long to lead the water to the forebay.

3) The water conductor system consisting of RCC, partly cut and cover, conduit of size 10.5m x 7m and m long to lead the water to the forebay. Project: Mannapitlu Mini Hydel Scheme - 15 MW Overview: Mannapitlu Mini Hydel Scheme is the first of the 4 cascading Mini Hydro Electric Projects planned on Gurupur river in Dakshina Kannada District of

More information

ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST:

ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST: Sr. Item Description No. (A) Material Management Cell 1 Meters(All types) 2 GSM Modem ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST: 3 Metering Cubicles 4 L.T. Distribution Box 5 L.T. XLPE Cable 6

More information

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM The Singareni Collieries Company Limited (A Government Company) CENTRAL WORK SHOP KOTHAGUDEM-507101 Vendor meet for supply, erection & commissioning of 3T capacity induction melting furnace on Trunkey

More information

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy. Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that

More information

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard

More information

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv 06B1-E-0002 Small Space Requirement, High Reliability and Safety ー 72.5 to 145 kv GIS, SDH314/SDHa314

More information

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to

More information

PART A: FINANCIAL BID

PART A: FINANCIAL BID TENDER DOCUMENT FOR INTERIOR FURNISHING WORKS (excluding ELECTRICAL & DATA CABELING WORK) IN BANK OF INDIA BRANCH AT FARIDABAD,(SME BRANCH), HARYANA BANK OF INDIA, ZONAL OFFICE, STAR HOUSE, S.C.O. NO.

More information

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing

More information

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR. AMENDMENT-02 TO TECHNICAL SPECIFICATION FOR ELEVATOR (SPEC NO. PE-TS-408-502-A001) 1x800 MW WANAKBORI STPP. CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR. CL. NO. 2.0 Scope of equipment supply

More information

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Tender Schedule. Sl. No. Particulars Quantity Unit Rate ` Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol 04-62-70001 4 WD NISSAN PATROL STATION WAGON SGL, 4500 cc 2 Unit Petrol Engine 04-62-70002 Spare parts kits for 4 WD Nissan Patrol 4 Set Station Wagon 04-62-70003 Belt-Fan 11720-03J00 4 Each 04-62-70004

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

HARYANA VIDYUT PRASARAN NIGAM LTD.

HARYANA VIDYUT PRASARAN NIGAM LTD. HARYANA VIDYUT PRASARAN NIGAM LTD. TECHNICAL SPECIFICATION SSD/S-03/R-1/DGM-605 TECHNICAL SPECIFICATION FOR 33 KV CAPACITOR BANKS CHIEF ENGINEER/MM HVPNL, PANCHKULA TELEPHONE & FAX: 0172-2583724 MARCH-2017-0

More information

: Material Description Quantity UOM

: Material Description Quantity UOM Page : 1 / 2 OIL INDIA LIMITED (A Govt. Of India Enterprise) Tel :033 2230 1657, 1658 4, India Exchange Place, Fax :91 33 2230 2596 Kolkata-700001 E-mail :oilcalmn@cal2.vsnl.net.in ANNEXURE-I Item No./

More information

Estimate of Under Ground Electrification Work

Estimate of Under Ground Electrification Work S.No. Description of Items Unit Rate Qty Amount 1 Supply, Installation, Testing and Commissioning of 3C x 300 Sq. mm. Al. conductor, armoured, XLPE insulated, PVC sheathed, 11KV cable in ready made underground

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise)

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise) DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED (A Govt of West Bengal Enterprise) CHIEF ENGINEER (PROCUREMENT), VIDYUT BHAVAN NOTICE INVITING TENDERS For CONSTRUCTION

More information

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV). Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV). Sr. No. Clause No Existing Proposed 1 8.0 Dischar ge device 2 15.0

More information

INVITATION TO TENDER MR 84/2016. SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station

INVITATION TO TENDER MR 84/2016. SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station INVITATION TO TENDER MR 84/2016 SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station Fiji Electricity Authority seeks reputable Manufacturer/Supplier

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

A REPORT ON. Undertaken at

A REPORT ON. Undertaken at A REPORT ON SUMMER TRAINING Undertaken at 20/13 kv Substaion at Bhinmal Under the guidance of Er. K. C. Gupta (executive engineer, 220KV GSS, Bhinmal) Er. A.P. Mathur (assistant engineer, 220KV GSS, Bhinmal)

More information

PRAGATI ENGINEERING COLLEGE

PRAGATI ENGINEERING COLLEGE Report on Industrial Visit to Power Grid 765/400 KV (GIS) Sub-Station No. of days of Visit : Two days Date(s) of Visit : 19 th September, 2017& 7 th October, 2017 Faculty In-charges : 4 Members 1. Mr.S.Ashokreddy,

More information

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES Tamil Nadu Transmission Corporation Limited Bharat Heavy Electricals Limited 400/110 KV Substation at Thappagundu & 400/230-110 KV Substation at Anikadavu, Technical specification for 420/245/132kV Isolators

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Sub-Transmission & Distribution System

Sub-Transmission & Distribution System Sub-Transmission & Distribution System (33 kv and Below Systems) Cost Data FY 2016-17 1/58 COST DATA FOR FY- 2017-18 PREFACE 1 This Cost Data has been prepared in pursuance to regulation 13 of HPERC (Recovery

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

APPENDIX C FACILITY ILLUSTRATION

APPENDIX C FACILITY ILLUSTRATION APPENDIX C FACILITY ILLUSTRATION 21m 21m 21m 0m 5.4m 3.5m access road (allow for water management on sides) Future Expansion 20m 24.5m 61m 49m 69m 20m Future Expansion 5m 100m 4.3m 9m 100m Space for MV

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

Need Assessment Document (NAD) DDUGJY

Need Assessment Document (NAD) DDUGJY Need Assessment Document (NAD) DDUGJY Index SNo. Details Page No. 1.0 General Instruction 3 2.0 Objectives of DDUGJY 5 3.0 Scope of works 7 4.0 General information of project area 10 5.0 Details of existing

More information

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test) ANNEXURE I SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test) Paper I & Paper II for General Category of S.C.C. Examination Paper I & Paper

More information

Page 1 of 5. Project : CATERPILLAR CM GENSETS PROJECT (RADIATOR COOLING) 2 x 16CM32, 6.3 kv, 50 Hz. TUS(S)PL Supply. Customer Supply DESCRIPTION

Page 1 of 5. Project : CATERPILLAR CM GENSETS PROJECT (RADIATOR COOLING) 2 x 16CM32, 6.3 kv, 50 Hz. TUS(S)PL Supply. Customer Supply DESCRIPTION 2 x 16CM32, 6.3 kv, 50 Hz GENSET PORTION 1.1 DIESEL ENGINE - CATERPILLAR 16CM32 2 1.2 Additional engine components (mounted on the engine) Electric turning devices 2 Gauge panels 2 Governors 2 Electric

More information

SUBSTATION DESIGN TRAINING

SUBSTATION DESIGN TRAINING 2017 SUBSTATION DESIGN TRAINING ADVANCE ELECTRICAL DESIGN & ENGINEERING INSITUTE (Registered under MSME& An ISO 9001:2008 CERTIFIED) Training Centre: Advance Group of Institutions C-1, Second Floor Near

More information

Metal Clad VCBs ~ Mk1

Metal Clad VCBs ~ Mk1 Metal Clad VCBs ~ Mk1 DUVI 150/40 ROLL ON FLOOR VCBs Range: 6kV, 00A, 1.5kA, 12kV, 150A, 40kA ( 4A000A Bus-Bars ) ` Widest range for MV (up to 6kV) Distribution Networks Megawin make metal clad VCB Panels

More information

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Modular Standardized Electrical and Control Solutions for Fast Track Projects Modular Standardized Electrical and Control Solutions for Supporting fast track projects ABB is the leading supplier of electrical and control equipment for power plants. The company offers a comprehensive

More information

NOTICE INVITING TENDER

NOTICE INVITING TENDER TENDER FOR SUPPLY, INSTALLATION AND COMMISSIONING OF 30kWp On Grid SOLAR POWER PLANT AT FACC/CHRD/LAKE HALL, BIDHAN CHANDRA KRISHI VISWAVIDYALAYA (BCKV), KALYAN, DIST NADIA, WEST BENGAL, INDIA, PIN 741235

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR Sl No Brief description of work item Unit Qty Rate Amount Total Rs A INTERNAL WIRING Supply, laying of 2mm thick approved make PVC conduit

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

III. Substation Bus Configurations & Substation Design Recommendations

III. Substation Bus Configurations & Substation Design Recommendations III. Substation Bus Configurations & Substation Design Recommendations 1.0 Introduction Pre-existing conditions, electrical arrangements or the criticality of the existing facility may limit this flexibility,

More information

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT 33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar,

More information

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD Soubhagya Nayak Associates Plot No-736,Sector-3,Niladrivihar,Chandrasekharpur,Bhubaneswar.21

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

Functional Specification Revision History

Functional Specification Revision History Functional Specification Revision History Revision Description of Revision Author Date B0 For comments Yale Zhou January 26, 2016 B1 Updated as per comments Yale Zhou February 1, 2016 Final issuance Yale

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

Sub-Transmission & Distribution System

Sub-Transmission & Distribution System 1/58 Sub-Transmission & Distribution System (33 kv and Below Systems) Cost Data FY 2017-18 2/58 COST DATA FOR FY- 2017-18 PREFACE 1 This Cost Data has been prepared in pursuance to regulation 13 of HPERC

More information

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system. MV Switchgear for CGMCOSMOS Fully gas insulated modular and compact (RMU)system Up to 24 kv Up to 27 kv mediumvoltage mediumvoltageag AG Langackerstrasse Langackerstrasse 25 25 CH CH 6330 6330 Cham Cham

More information

PART B: FINANCIAL BID

PART B: FINANCIAL BID Relationship beyond Bankjng TENDER DOCUMENT FOR ELECTRICAL (ELECTRICAL & DATA CABELING WORK ONLY) IN BANK OF INDIA BRANCH AT SECTOR 25 PANCHKULA BANK OF INDIA, ZONAL OFFICE, S.C.O. NO. 76-82, SECTOR 31-A,

More information

CHAPTER 6 POWER SUPPLY ARRANGEMENTS

CHAPTER 6 POWER SUPPLY ARRANGEMENTS 6.1 Power Requirements CHAPTER 6 Power supply is the lifeline of Metro System POWER SUPPLY ARRANGEMENTS Electricity is required for operation of Metro system for running of trains, station services (e.g.

More information

LV MV HV SPECIALISTS. Cable Installation, Jointing, Substation & Electrical Equipment TOTAL SUPPLY ELECTRICAL POWER PRODUCTS

LV MV HV SPECIALISTS. Cable Installation, Jointing, Substation & Electrical Equipment TOTAL SUPPLY ELECTRICAL POWER PRODUCTS LV MV HV SPECIALISTS Cable Installation, Jointing, Substation & Electrical Equipment TOTAL SUPPLY ELECTRICAL POWER PRODUCTS 100,000+ PRODUCTS 100+ BRANDS International were established in 1985 and are

More information

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear. Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical

More information

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION OF DG Sets & Sychronising Panel FOR for multistoreyed Boy s Hostel SARDAR VALLABHBHAI NATIONAL INSTITUTE OF TECHNOLOGY, SURAT,

More information

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Issue 3 2012 SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) www.energynetworks.org 2012 Energy Networks

More information

Chapter 6 Generator-Voltage System

Chapter 6 Generator-Voltage System Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals

More information

Generation Interconnection Facilities Study For

Generation Interconnection Facilities Study For Generation Interconnection Facilities Study For Prepared for: Prepared by: SCE&G Transmission Planning May 27, 2015 TABLE OF CONTENTS General Discussion... Page 3 Generator Interconnection Specifications...

More information

VOLUME III DRAWINGS. Jammu & Kashmir. KARNAH HEP (3 x 4 MW) UPGRADATION OF KARNAH HEP DETAILED PROJECT REPORT FOR. (FROM 2 x 1 MW To 3 x 4 MW)

VOLUME III DRAWINGS. Jammu & Kashmir. KARNAH HEP (3 x 4 MW) UPGRADATION OF KARNAH HEP DETAILED PROJECT REPORT FOR. (FROM 2 x 1 MW To 3 x 4 MW) KARNAH HEP ( x 4 MW) Jammu & Kashmir DETAILED PROJECT REPORT FOR UPGRADATION OF KARNAH HEP (FROM x MW To x 4 MW) VOLUME III DRAWINGS May 06 J&K State Power Development Corporation Synergics Hydro (India)

More information

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9 Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6

More information