Elettrotek Kabel Group was established in 2001 in Bagnolo. Italy,

Size: px
Start display at page:

Download "Elettrotek Kabel Group was established in 2001 in Bagnolo. Italy,"

Transcription

1

2 Elettrotek Kabel Group was established in 2001 in Bagnolo. Italy, born from the desire to supply specific cables to the local market, with the aim to expand worldwide. Expansion which was made possible by the opening of offices in Poland, Czech Republic, India, Switzerland, USA and Germany. Permitting Elettrotek Kabel Group to touch all sides of the world. From this advantage point we are able to better provide our cables and technical services which are of the highest standards and focused in different sectors being automation, port, steel, mining, oil & gas and wind & solar energy industries worldwide. With a high level of knowledge gained by over ten years of experience in providing the best cable solutions to our customers in each of these sectors. Elettrotek Kabel has now become a point of reference to the biggest players in the these specific fields of industry.

3 Worldwide presence:

4 The business units: Our stock in Italy ELETTROTEK KABEL business unit! Certifications & Normatives: ISO 9001:2008 UL approval CSA approval GOST approval

5

6 INDUSTRIAL PLANT CABLES low Voltage cables: GAALFLEX CONTROL N07V-K and H07V-K 1 GAALFLEX CONTROL H05V-U/H07V-U and H07V-R 2 GAALSHIP N07G9-K 3 SG-Flex (H01N2-D) 4 FROR 300/500V and 450/750 5 FROH2R 6 FR2OHH2R 7 FRORAR 450/750 V 8 FG7(O)R 0,6/1 kv 9/10 RG7(O)R 0,6/1 KV 11/12/13 N1VV-K 14/15 FG7(O)H1R 16/17 FG7OH2R 0,6/1 kv 18/19 N1VC7V-K 20 GAALFLEX VFD FG7(O)CR 21 GAALFLEX VFD FG7(O)HH2R 22 FG7(O)NR 0,6/1 kv 23/24 FG7(O)RAR 0,6/1 kv 25/26 FG7(O)H2RAR 0,6/1 kv 27 FG7(O)HH2RAR 0,6/1 kv 28/29 GAALFLEX CONTROL 1000 BH 30/31 FG7(O)M1 0,6/1 kv 32/33 FG7(O)H2M1 0,6/1 kv 34/35 FG7(O)AM1 0,6/1 kv 36/37 NYY-J/O 0,6/1 kv 38/39 (N)AYY-J/O 0,6/1 kv 40/41 GAALFLEX NYCY 42 GAALFLEX VFD NYCWY 43 (N)AYCWY 44 (N)2XY-J/O 45/46 U-1000 R2V 47/48 U-1000 RV FV 49/50 RV-K 51 RE4(O)R (XLPE/PVC) 52/53 FE4(O)CR 54 RE4(O)FR (XLPE/PVC/SWA/PVC) 55/56 RE4(O)FR (XLPE/PVC/SWA/PVC) BS /58 RE4(O)M1 (XLPE/LS0H)(RE4(O)H) 59/60 RE4(O)FM1 (XLPE/LS0H/SWA/LS0H) 61/62 N2XH 63/64 N2XCH 65/66 GAALFLEX CONTROL 07BQ-F 67 GAALFLEX CONTROL (H)07BQ-F 68 Index

7 INDUSTRIAL PLANT CABLES medium Voltage cables: RG7H1R 69/70 RG7H1OR 71/72 RG7H1NR 73/74 RG7H1ONR 75/76 RG7H1ZR 77/78 RG7H1OZR 79/80 ARG7H1E 81 ARG7H1EX 82 RG7H1M1 83/84 RG7H1OM1 85/86 RG7H1NM1 87/88 RG7H1ONM1 89/90 RG7H1ZM1 91/92 RG7H1OZM1 93/94 RG7H1O(GS)M1 95 RE4H1R (XLPE/CTS/PVC) 96/97 RE4H1OR (XLPE/CTS/PVC) 98/99 RE4H1RFR (XLPE/CTS/PVC/AWA/PVC) 100/101 RE4H1ORFR (XLPE/CTS/PVC/SWA/PVC) 102/103 ARE4H1R 104 ARE4H1RX 105 ARE4H5(GS)E 106 ARE4H5(GS)EX 107 RE4H1M1 (XLPE/CTS/LS0H) 108/109 RE4H1OM1 (XLPE/CTS/LS0H) 110/111 NSGAFOU 3 kv 112 NSHXAFO 3 kv 113 N2XSY 6/10 kv, 12/20 kv, 18/30 kv PVC-jacket 114 N2XS2Y 6/10 kv, 12/20 kv, 18/30 115/116 N2XS(F)2Y 6/10 kv, 12/20 kv, 18/30 kv 117 N2XSEY 6/10 kv, 12/20 kv, 18/30 kv 118 NF2XSE(GS)Y 119/120/121/122 NA2XSY 6/10 kv, 12/20 kv, 18/30 kv 123 NA2XS(F)2Y 6/10 kv, 12/20 kv, 18/30 kv 124 NA2X(FL)2Y 6/10 kv, 12/20 kv, 18/30 kv 125 instrumentation cables: FR2XOHR 300/500 and 450/750 V 127 FR2XHOHR 300/500 V 128 FR2XOHRAR 450/750 V 129 FR2XHOHRAR 300/500 V 130 RD-Y(St)Y 131 REXOHR (PE/PVC) 132 REXHOHR (PE/PVC) 133 RE-2Y(St)Yv 134/135 RE-2Y(St)Yv-fl 136/137 Index

8 INDUSTRIAL PLANT CABLES RE-2Y(St)Y PiMF 138/139 RE-2Y(St)Yv PiMF 140 RE-2Y(St)YRY 141/142 RE-2Y(St)YRY 143/144 RE-2Y(St)YRY PiMF 145/146 RE-2Y(St)YSWAY 147/148 RE-2X(St)Y Fl 149 RE-2X(St)Yv PiMF 150 RE-2X(St)YSWAY 151/152 RE4XOHM1(XLPE/LS0H) 153 RE4XHOHM1(XLPE/LS0H) 154 RE4XOHEFR(XLPE/CAM/PE/SWA/PVC) 155 RE4XHOHM1FM1(MGT/XLPE/IAM/CAM/LS0H/SWA/ LS0H) 156 SECURITY cables: J-Y(St)Y Lg Fire warning 157 J-H(St)H Fire warning 158 JE-H(St)H Fire warning 159 JE-H(St)HRH Fire warning 160 JE-H(St)H Orange 161 FTG10(O)M1 0,6/1 kv 162/163 FTG10(O)HM1 164 N2XH-FE 180/E /166 N2XCH-FE 180/E /168 NHXH-FE 180/E /170 NHXCH-FE 180/E /172 N2XH-FE 180/E /174 N2XCH-FE 180/E /176 NHXH-FE 180/E /178 NHXCH-FE 180/E /180 FG4OHM1 PH FG4OHM1 PH FG4OHM1 PH telephone AND ELECTRONIC cables: A-2Y(L)2Y 185/186 A-2YF(L)2Y 187/188 A-Y(St)YSYv 189 J-YY Bd 190 J-Y(St)Y Lg 191/192 JE-Y(St)Y 193 JE-LiYCY 194 J-2Y(St)H 195 J-H(St)H 196 JE -LiHCH 197 TECHNICAL DATA 199/222 Index

9

10 LOW VOLTAGE CABLES GAALFLEX CONTROL N07V-K and H07V-K <HAR> Conductor: Outer Sheat: flexible red copper conductor Cl.5,acc.to IEC PVC,type TI1, for the coloration,see technical data (PAG.207) Features: UNEL TABLE Nominal voltage: Test voltage: Temperature range: 450/750 V 2,5 kv -10 o C / + 70 o C Max. short circuit temperature: 160 o C Min. bending radius: D 8 8<D 12 12<D 20 D>20 fixed laying: 3D 3D 4D 4D flexible applications: 5D 5D 6D 6D Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC N07V-K H07V-K 31380E01010M10 1x1 2,9 9, E01010M15 1x1,5 3,1 14, E01010M25 1x2,5 3,8 24, E01010M40 1x4 4,4 38, E01010M60 1x6 4,9 57, E01010M61 1x10 6,4 96, E01010M62 1x16 7,4 153, E01010M63 1x25 9,1 240, E01010M64 1x35 10,4 336, E01010M65 1x50 12, E01010M66 1x70 13, / E01010M67 1x95 15, / E01010M68 1x120 17, / E01010M69 1x150 19, MCM 31380E01010M70 1x185 21, MCM 31380E01010M71 1x240 24, MCM <HAR> 31320E01010M10 1x1 2,9 9, E01010M15 1x1,5 3,1 14, E01010M25 1x2,5 3,8 24, E01010M40 1x4 4,4 38, E01010M60 1x6 4,9 57, E01010M61 1x10 6,4 96, E01010M62 1x16 7,4 153, E01010M63 1x25 9,1 240, E01010M64 1x35 10,4 336, E01010M65 1x50 12, E01010M66 1x70 13, / E01010M67 1x95 15, / E01010M68 1x120 17, / E01010M69 1x150 19, MCM 31320E01010M70 1x185 21, MCM 31320E01010M71 1x240 24, MCM Other dimensions and colours available on request. 1

11 LOW VOLTAGE CABLES GAALFLEX CONTROL H05V-U/H07V-U H07V-R <HAR> Conductor: Outer Sheat: H05V-U solid or stranded red copper conductor Cl. 1 or 2, acc. to IEC 60228, DIN VDE ,5-1 mm 2 - H05V-U Cl.1 1,5-6 mm2 - H07V-U Cl mm 2 -H07V-R Cl.2 PVC,type TI1,for the coloration,see the technical data (PAG.207) Features: UNEL TABLE Nominal voltage: H05V-U: H07V-U/R: Test voltage H05V-U: 2 kv acc.to DIN VDE 0281 part 2 + HD 21.2 H07V-U/R: 2,5 kv acc.to DIN VDE 0281 part 2 + HD 21.2 Temperature range: -10 o C / + 70 o C Max. short circuit temperature: 160 o C Min. bending radius: D 8 8<D 12 12<D 20 D>20 fixed laying: 3D 3D 4D 4D flexible applications: 5D 5D 6D 6D Resistance: 300/500 V 450/750 V Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC D01010M05 1x0,5 2,1 4, D01010M07 1x0,75 2,3 7, D01010M10 1x1 2,5 9, H07V-U/R 31370E01010M15 1x1,5 2,9 14, E01010M25 1x2,5 3,5 24, E01010M40 1x4 4 38, E01010M60 1x6 4,7 57, E01010M61 1x10 6,1 96, E01010M62 1x16 7,1 153, E01010M63 1x25 8,9 240, E01010M64 1x35 9,9 336, E01010M65 1x50 11, E01010M66 1x70 13, / E01010M67 1x95 15, / E01010M68 1x120 17, / E01010M69 1x150 19, MCM 31370E01010M70 1x185 21, MCM 31370E01010M71 1x240 24, MCM 31370E01010M72 1x MCM 31370E01010M73 1x400 30, MCM Other dimensions and colours available on request. 2

12 LOW VOLTAGE CABLES GAALSHIP N07G9-K Single core, halogen-free flexible control cable, 450/750 V Conductor: flexible red copper conductor Cl.5,acc.to IEC Outer Sheat: rubber,type G9,for the coloration,see the technical data (PAG.207) Features: Registro Italiano Navale (RINA) Nominal voltage: 450/750 V Test voltage: 2,5 kv Min. Bending radius: 4 x d Temperature range: -15 C to + 90 Short circuit temperature: C Resistance: - Flame retardant and self-extinguishing acc. to: IEC DIN EN Halogen free acc. to: EN IEC , DIN VDE 0482 part Corrosiveness of conflagration gases acc. to: IEC DIN EN , - Smoke density acc. to: IEC EN 61034, I Acc. to I UNEL Part.no 12030E01010M15 1x1,5 3,2 14, E01010M25 1x2, E01010M40 1x4 4,3 38, E01010M60 1x6 5,1 57, E01010M61 1x10 6, E01010M62 1x16 7,5 153, E01010M63 1x25 9, E01010M64 1x35 10, E01010M65 1x50 12, E01010M66 1x70 13, / E01010M67 1x95 15, / E01010M68 1x120 17, / E01010M69 1x150 20, MCM 12030E01010M70 1x185 22, MCM 12030E01010M71 1x240 25, MCM Other dimensions and colors available on request. 3

13 LOW VOLTAGE CABLES SG-Flex (H01N2-D) <HAR> Conductor: flexible red copper conductor Cl.5,acc.to IEC Outer Sheat: black (RAL 9005),neoprene outer jacket,chlorinated for the coloration,see the technical data (PAG.207) Application: wires for arc welding, electrode holders for use with portable 100 V Nominal voltage: 100/100 V Test voltage: 1 kv Temperature range Fixed installation: - 40 o C to +85 o C Flexible installation: - 25 o C to +85 o C Short circuit temperature: C Min. bending radius: 8 x d Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Oil resistant: IEC ,DIN VDE 0473 part, H01N2-D Single wire Ø max.value mm. Sheat wall-thickness nom.value mm B01010M61 1x10 0,21 2,0 8, B01010M62 1x16 0,21 2,0 9, B01010M63 1x25 0,21 2,0 11, B01010M64 1x35 0,21 2,0 12, B01010M65 1x50 0,21 2,2 14, B01010M66 1x70 0,21 2,4 17, / B01010M67 1x95 0,21 2,6 19, / B01010M68 1x120 0,51 2,8 21, / B01010M69 1x150 0,51 3,0 23, MCM 31390B01010M70 1x185 0,51 3, MCM Other dimensions and colors available on request. 4

14 LOW VOLTAGE CABLES FROR 300/500V and 450/750V Conductor: Insulation: Colour core: Outer Sheath: flexible red copper conductor Cl.5, acc.to IEC PVC,type TI2 DIN VDE 0293,HD 308 S2 until 6 conductor. from 7 conductors, black with progressively numbered and Y/G grey (RAL 7035),PVC,type TM2 Features: according to IEC Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Min. bending radius: Fixed installation: Flexible installation: Max. tensile stress: Fixed installation: Flexible installation: Max. short circuit temperature: 300/500 V 1,2 kv / 2,5 kv - 15 o C / + 70 o C 0 o C / + 70 o C 4 x d 10 x d 1,5 kg x mm 2 5 kg x mm o C 450/750 V Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC FROR 300/500 V FROR 450/750 V Part.no 46010D80071M10 7G1 11,1 67, D80101M10 10G1 14, D80121M10 12G1 14,8 115, D80161M10 16G1 16,5 153, D80191M10 19G1 17,7 182, D80241M10 24G1 20,7 230, D80271M10 27G1 21,4 259, D80071M15 7G1,5 13,1 100, D80101M15 10G1,5 16, D80121M15 12G1,5 17,5 172, D80161M15 16G1,5 19,4 230, D80191M15 19G1,5 20,5 273, D80241M15 24G1,5 24,3 345, D80271M15 27G1,5 25,0 388, E83020M10 2x1 8,7 19, E83020M15 2x1,5 9,2 28, E83020M25 2x2,5 11, E83020M40 2x4 12,5 76, E83020M60 2x6 13,9 115, E82031M10 3G1 9,1 28, E82031M15 3G1,5 9,8 43, E82031M25 3G2,5 11, E82031M40 3G4 13,5 115, E82031M60 3G6 14,9 172, E82041M10 4G1 9,9 38, E82041M15 4G1,5 10,9 57, E82041M25 4G2,5 12, E82041M40 4G4 14,7 153, E82041M60 4G6 16,3 230, E82051M10 5G1 11, E82051M15 5G1,5 12, E82051M25 5G2,5 14, E82051M40 5G4 16, E82051M60 5G6 18, Other dimensions and colours available on request. 5

15 LOW VOLTAGE CABLES FROH2R Conductor: flexible red copper conductor Cl.5, acc.to IEC Nominal voltage: 450/750 V Insulation: Colour core: Screen: Outer Sheat: PVC,type TI2 DIN VDE 0293,HD 308 S2 red copper braid grey (RAL 7035),PVC,type TM2 Test voltage: Max. short circuit temperature: fixed installation: lexible application: Temperature range: fixed installation: flexible application: 2,5 kv 160 o C 150 o C -15 o C / + 70 o C 0 o C / + 70 o C Min. bending radius: 12 x d Features: according to IEC Max. tensile stress: fixed installation: flexible application: Resistance: 50 N/mm 2 20 N/mm 2 Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Oil resistant acc. to: IEC , DIN VDE 0473 part E83020M10 2x1 8,6-106, E83020M15 2x1,5 9 80,5 118, E83020M25 2x2,5 10,7-169, E83020M40 2x4 12,1-218, E83020M60 2x6 13, E82031M10 3x1 9 58,2 123, E82031M15 3G1,5 9,45 80,5 142, E82031M25 3G2,5 11, , E82031M40 3G E82031M60 3G6 14,4-364, E82041M10 4G1 9,7 75,7 144, E82041M15 4G1,5 10,5 95,6 173, E82041M25 4G2,5 12,2 146,2 242, E82041M40 4G4 14,3 210,7 345, E82041M60 4G6 15,6 298,4 441, E82051M10 5G1 10,7 86,1 175, E82051M15 5G1,5 11,4 113, E82051M25 5G2,5 13, E82051M40 5G , E82051M60 5G6 17,2 358,7 536,7 10 Other dimensions and colours available on request. 6

16 LOW VOLTAGE CABLES FR2OHH2R Conductor: flexible red copper conductor Cl.5, acc.to IEC Insulation: PVC,type R2 Colour core: DIN VDE 0293,HD 308 S2 Screen: aluminium tape and red copper braid Outer sheath: grey (RAL 7001),PVC,type TM2 Features: acc. to IEC Nominal voltage: 450/750 V Test voltage: 1,2 kv Temperature range: Fixed installation: - 15 C / + 70 C Flexible installation: - 0 C / + 70 C Max. short circuit temperature: Fixed installation: C Flexible installation: C Min. bending radius: 12 x d Max. tensile stress: Fixed installation: 50 N/mm 2 Flexible installation: 20 N/mm 2 Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC Oil resistant acc. to: IEC , DIN VDE 0473 part E83020M10 2x1 9,9 19, E83020M15 2x1,5 10,5 43, E83020M25 2x2,5 12,8 48, E83020M40 2x4 14,5 76, E83020M60 2x6 16,1 115, E82031M10 3G1 10,4 28, E82031M15 3G1,5 11,3 43, E82031M25 3G2,5 13,7 72, E82031M40 3G4 15,4 115, E82031M60 3G6 17,0 172, E82041M10 4G1 11,5 38, E82041M15 4G1,5 12,6 57, E82041M25 4G2,5 14,9 96, E82041M40 4G4 16,7 153, E82041M60 4G6 18,7 230, E82051M10 5G1 12,0 48, E82051M15 5G1,5 12,5 72, E82051M25 5G2,5 14,5 120, E82051M40 5G4 16,1 192, E82051M60 5G6 18,5 288, Other dimension and colours available on request. 7

17 LOW VOLTAGE CABLES FRORAR 450/750V Conductor: Insulation: Colour core: Inner Sheath: Armour: Outer Sheath: Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: 450/750 V 2,5 kv flexible red copper conductor Cl.5, acc.to IEC PVC,type R2 black with numbered and Y/G earth-core thermoplastic compound braid of galvanized steel wires transparent, PVC,typeTM2-15 C / + 70 C 0 C / + 70 C Max. short circuit temperature: Min. bending radius: Resistance: Features: according to IEC C 8 x d Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Oil resistant acc. to: IEC , DIN VDE 0473 part ET1020M05 2x0,5 7,1 9, ET0031M05 3G0,5 7,3 14, ET0041M05 4G0,5 8,0 19, ET0051M05 5G0,5 8, ET0071M05 7G0,5 8,9 33, ET0101M05 10G0,5 10, ET0121M05 12G0,5 11,3 57, ET0161M05 16G0,5 12,6 76, ET0241M05 24G0,5 15,2 115, ET1020M07 2x0,75 7,7 14, ET0031M07 3G0,75 8,0 21, ET0041M07 4G0,75 8,7 28, ET0051M07 5G0,75 9, ET0071M07 7G0,75 10,2 50, ET0101M07 10G0,75 12, ET0121M07 12G0,75 13,0 86, ET0161M07 16G0,75 14,0 115, ET0241M07 24G0,75 16,9 345, ET1020M10 2x1 8,1 19, ET0031M10 3G1 8,4 28, ET0041M10 4G1 9,0 38, ET0051M10 5G1 10, ET0071M10 7G1 10,8 67, ET0101M10 10G1 13, ET0121M10 12G1 14,0 115, ET0161M10 16G1 15,8 153, ET0241M10 24G1 18,1 230, ET1020M15 2x1,5 9,1 28, ET0031M15 3G1,5 9,9 43, ET0041M15 4G1,5 10,6 57, ET0051M15 5G1,5 11, ET0071M15 7G1,5 12,5 100, ET0101M15 10G1,5 15, ET0121M15 12G1,5 16,3 172, ET0161M15 16G1,5 17,7 230, ET0241M15 24G1,5 21,4 345, ET1020M25 2x2,5 10,7 43, ET0031M25 3G2,5 11, ET0041M25 4G2,5 12, ET0051M25 5G2,5 13, ET0071M25 7G2,5 15, ET0101M25 10G2,5 18, ET0121M25 12G2,5 19, ET0161M25 16G2,5 21, ET0241M25 24G2,5 24, ET1020M40 2x4 12,7 76, ET0031M40 3G4 13,3 115, ET0041M40 4G4 15,1 153, ET0051M40 5G4 16, ET1020M60 2x6 14,1 115, ET0031M60 3G6 15,4 172, ET0041M60 4G6 16,6 230, ET0051M60 5G6 17, ET1020M61 2x10 17, ET0031M61 3G10 18, ET0041M61 4G10 20, ET0051M61 5G10 22, ET1020M62 2x16 19,9 307, ET0031M62 3G16 21,6 460, ET0041M62 4G16 23,4 614, ET1020M63 2x25 23, ET0031M63 3G25 25, ET0041M63 4G25 27, Other dimensions and colours available on request. 8

18 LOW VOLTAGE CABLES FG7(O)R 0,6/1 kv Conductor: Insulation: Colour core: Outer sheath: flexible red copper conductor Cl.5, acc.to IEC rubber,type G7 1 core: black 2 cores: blue, brown 3 cores: brown, black, grey (or blue, brown, Y/G) 4 cores: blue, brown, black, gray, (or Y/G instead blue) 5 cores: Y/G, blue, brown, black, gray, (or black instead Y/G) Multi cores: black with numbers grey (RAL 7035),PVC,type RZ Features: acc. to IEC Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Max tensile stress: Min. Bending Radius: Temperature at conductor: in service: in short circuit: Resistance: 600/1000 V 4 kv -25 o C / + 90 o C 0 o C / + 90 o C 5 kg x mm 2 4 x d + 90 o C o C Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC POWER 46050G8L010M40 1x4 7,5 38, G8L010M60 1x6 8 57, G8L010M61 1x10 8, G8L010M62 1x , G8L010M63 1x G8L010M64 1x35 12, G8L010M65 1x G8L010M66 1x / G8L010M67 1x95 18, / G8L010M68 1x / G8L010M69 1x150 23, MCM 46050G8L010M70 1x MCM 46050G8L010M71 1x240 28, MCM 46050G8L010M72 1x MCM 46050G8L010M73 1x400 36, MCM 46050G8L010M74 1x MCM 46050G8L010M75 1x MCM 46050G83020M15 2x , G83020M25 2x G83020M40 2x4 12,5 76, G83020M60 2x6 13, G83020M61 2x G83020M62 2x G83020M63 2x G83020M64 2x G83020M65 2x G83020M66 2x /0 9

19 LOW VOLTAGE CABLES FG7(O)R 0,6/1 kv CONTROL 46050G82031M15 3G1.5 12,5 43, G82031M25 3G2.5 13, G82031M40 3G , G82031M60 3G G82031M61 3G G82031M62 3G16 20, G82031M63 3G25 24, G82031M64 3G35 27, G82031M65 3G G82031M66 3G70 35, / G82031M67 3G / G82040M15 4x , G82040M25 4x G82040M40 4x4 14,5 153, G82040M60 4x G82040M61 4x G82040M62 4x , G82040M63 4x25 25, G83035M64 3x35+1x25 28, G82035M64 3x35+1G25 28, G83035M65 3x50+1x25 32, G82035M65 3x50+1G25 32, G83035M66 3x70+1x G82035M66 3x70+1G G83035M67 3x95+1x G82035M67 3x95+1G G83035M68 3x120+1x / G82035M68 3x120+1G / G83035M69 3x150+1x95 52, / G82035M69 3x150+1G95 52, / G83035M70 3x185+1x95 57, / G82035M70 3x185+1G95 57, / G83035M71 3x240+1x150 65, G82035M71 3x240+1G150 65, G82041M15 4G , G82041M25 4G G82041M40 4G4 14,5 153, G82041M60 4G , G82041M61 4G G82041M62 4G , G82041M63 4G25 25, G82051M15 5G1, G82051M25 5G2, G82051M40 5G G82051M60 5G6 17, G82051M61 5G G82051M62 5G16 24, G82051M63 5G G83050M15 5G1,5 14, G81070M15 7G1,5 15, G81100M15 10G1, G81120M15 12G1,5 19,5 172, G81160M15 16G1, , G81190M15 19G1, , G81240M15 24G1,5 25,5 345, Other dimensions and colours available on request. 10

20 LOW VOLTAGE CABLES RG7(O)R 0,6/1 kv Conductor: solid or stranded red copper conductor Cl. 1 or 2, acc. to IEC Insulation: Rubber type G7 Colour code: 1 core: black 2 cores: blue-brown 3 cores: brown or blue, brown, Y/G 4 cores: blue, brown, black, gray 5 cores: Y/G, blue, brown, black, gray Multi cores: black with numbers Wrapping: Outer sheath: not fibrous and not hygroscopic filler light grey (RAL 7035),PVC,type RZ Nominal voltage: 600/1000 V Test voltage: 3,5 kv Temperature range: 0 C up to + 90 C Max. short circuit temperature: for sections up to 240 mm 2 : C for sections over 240 mm 2 : C Min. bending radius: rigid cables, class 1 and 2 6 x D Max. pulling installation: during installation: 50 N/mm 2 static stress: 15 N/mm 2 Resistance: Flame retardant acc. to: PVC sel-extinguishing and flame retardant acc.to DIN VDE 0482 part /EN /IEC On request: DIN VDE 0482 part , EN , IEC C Features: UNEL TABLES Applications: Power and control use outdoor and indoor applications, even wet. Suitable for fixed installation at open air, in tube or canals, masonry, metals structures, overhead wire and for direct and indirect undergrround wiring. 11

21 LOW VOLTAGE CABLES RG7(O)R 0,6/1 kv approx, 46060G8L010M15 1x1,5 6,4 14, G8L010M25 1x2,5 6,9 24, G8L010M40 1x4 7,5 38, G8L010M60 1x6 8,1 57, G8L010M61 1x10 9,0 96, G8L010M62 1x16 10,0 153, G8L010M63 1x25 11,7 240, G8L010M64 1x35 13,0 336, G8L010M65 1x50 14,7 480, G8L010M66 1x70 16,6 672, / G8L010M67 1x95 18,6 912, / G8L010M68 1x120 20,5 1152, / G8L010M69 1x150 22,8 1440, MCM 46060G8L010M70 1x185 25,0 1776, MCM 46060G8L010M71 1x240 27,9 2304, MCM 46060G8L010M72 1x300 30,7 2880, MCM 46060G8L010M73 1x400 35,0 3840, MCM 46060G8L010M74 1x500 38,6 4800, MCM 46060G83020M15 2x1,5 11,5 28, G83020M25 2x2,5 12,4 48, G83020M40 2x4 13,6 76, G83020M60 2x6 14,7 115, G83020M61 2x10 16,6 192, G83020M62 2x16 18,6 307, G83020M63 2x25 22,1 480, G83020M64 2x35 24,6 672, G83020M65 2x50 28,1 960, G83020M66 2x70 31,7 1344, / G83020M67 2x95 35,9 1824, / G83020M68 2x120 39,8 2304, / G82031M15 3G1,5 12,0 43, G82031M25 3G2,5 13,0 72, G82031M40 3G4 14,3 115, G82031M60 3G6 15,5 172, G82031M61 3G10 17,5 288, G82031M62 3G16 19,7 460, G82031M63 3G25 23,4 720,

22 LOW VOLTAGE CABLES RG7(O)R 0,6/1 kv 46060G82031M64 3G35 26,2 1008, G82031M65 3G50 29,9 1440, G82031M66 3G70 34,1 2016, / G82031M67 3G95 38,3 2736, / G82031M68 3G120 44,7 3456, / G82031M69 3G150 42,5 4320, MCM 46060G82031M70 3G185 52,9 5328, MCM 46060G82031M71 3G240 59,3 6912, MCM 46060G83040M15 4x1,5 12,9 57, G83040M25 4x2,5 14,0 96, G83040M40 4x4 15,4 153, G83040M60 4G6 16,7 230, G83040M61 4x10 19,0 384, G83040M62 4x16 21,5 614, G83040M63 4x25 25,7 960, G83035M64 3x35+1x25 28,0 1248, G83035M65 3x50+1x25 31,1 1680, G83035M66 3x70+1x35 35,4 2352, / G83035M67 3x95+1x50 40,3 3216, / G83035M68 3x120+1x70 44,9 4128, / G83035M69 3x150+1x95 50,3 5232, MCM 46060G83035M70 3x185+1x95 54,9 6240, MCM 46060G83035M71 3x240+1x150 62,8 8352, MCM 46060G83035M72 3x300+1x150 67, , MCM 46060G83035M73 3x400+1x240 78, , MCM 46060G82035M64 3x35+1G25 28,0 1248, G82035M65 3x50+1G25 31,1 1680, G82035M66 3x70+1G35 35,4 2352, / G82035M67 3x95+1G50 40,3 3216, / G82035M68 3x120+1G70 44,9 4128, / G82035M69 3x150+1G95 50,3 5232, MCM 46060G82035M70 3x185+1G95 54,9 6240, MCM 46060G82035M71 3x240+1G150 62,8 8352, MCM 46060G82035M72 3x300+1G150 67, , MCM 46060G82035M73 3x400+1G240 78, , MCM 46060G82051M15 5G1,5 13,8 260, G82051M25 5G2,5 15,0 330, G82051M40 5G4 16,5 460, G82051M60 5G6 18,1 288, G82051M61 5G10 20,6 480, G82051M62 5G16 23,4 768, G82051M63 5G25 28,0 1200, G82051M64 5G35 31,5 1680, G82051M65 5G50 36,5 2400, Other dimension and colours available on request. 13

23 LOW VOLTAGE CABLES N1VV-K Conductor: Insulation: Colour core: Outer sheath: flexible red copper conductor Cl. 5, acc to IEC PVC, type R2 2 cores: blue-brown, 3 cores: brown-black-gray (or blue-brown-y/g), 4 cores: blue-brown-black-gray (or Y/G instead blue). 5 cores: Y/G-blue-brown-black-gray (or black instead Y/G), Multicores: black with numbers. light blue (RAL 5012), PVC, type R2 Features: Indoor and outdoor use acc. to I 20-14, 20-11, 20-29, Nominal voltage: 600/1000 kv Test voltage: 4 kv Temperature range: 0 o C / + 70 o C Max. short circuit temperature: 160 o C Min. bending radius: Power cores: 4 x D Control cores: 6 x D Tensile stress: 5 kg/mm 2 Current carrying capacity: acc. to I UNEL Resistance: Flame retardant acc. to: IEC C, DIN VDE 0482 part EN GB3020M15 2x1,5 12,5 38, GB3020M25 2x2,5 13,4 48, GB3020M40 2x4 15,6 76, GB3020M60 2x6 16,8 115, GB3020M61 2x10 18,7 192, GB3020M62 2x16 20,9 307, GB3020M63 2x25 24,5 480, GB3020M64 2x35 27,1 672, GB3020M65 2x50 31,2 960, GB3020M66 2x70 34,8 1344, / GB2031M15 3G1,5 13,1 43, GB2031M25 3G2,5 14,1 72, GB2031M40 3G4 16,4 115, GB2031M60 3G6 17,7 172, GB2031M61 3G10 19,8 288, GB2031M62 3G16 22,1 460, GB2031M63 3G25 26,0 720, GB2031M64 3G35 28,9 1008, GB2031M65 3G50 33,3 1440, GB2031M66 3G70 37,4 2016, / GB2031M67 3G95 42,8 2736, / GB2041M15 4G1,5 14,0 57, GB2041M25 4G2,5 15,2 96, GB2041M40 4G4 17,8 153, GB2041M60 4G6 19,2 230, GB2041M61 4G10 21,5 384, GB2041M62 4G16 24,2 614, GB2041M63 4G25 28,5 960,

24 LOW VOLTAGE CABLES N1VV-K 46070GB2051M15 5G1,5 15,0 72, GB2051M25 5G2,5 16,3 120, GB2051M40 5G4 19,2 192, GB2051M60 5G6 20,8 288, GB2051M61 5G10 23,4 480, GB2051M62 5G16 26,3 768, GB2051M63 5G25 31, GB2035M64 3x35+1G25 30, / GB2035M65 3x50+1G25 34, / GB2035M66 3x70+1G35 38, / GB2035M67 3x95+1G50 45, /0-1 Other dimensions and colours available on request. 15

25 LOW VOLTAGE CABLES FG7(O)H1R 0,6/1 kv Conductor: flexible red copper conductor Cl.5, acc.to IEC Insulation: rubber,type G7 Colour code: 1 core: black 2 cores: blue, brown 3 cores: brown, black, grey (or blue, brown, Y/G) 4 cores: blue, brown, black, gray, (or Y/G instead blue) 5 cores: Y/G, blue, brown, black, gray, (or black instead Y/G) Screen: Inner sheath: Outer sheath: Multi cores: black with numbers two alternated copper tapes filler compound grey (RAL 7035),PVC,type RZ. Nominal voltage: 600/1000 V Test voltage: 3,5 kv Temperature range: 0 C /+ 90 C Max. short circuit temperature: C Min. bending radius: power flexible cables,class. 5: 4 x D control flexible cables, class. 5: 6 x D Max. pulling installation: during installation: 50 N/mm 2 static stress: 15 N/mm 2 Resistance: Flame retardant acc. to: PVC sel-extinguishing and flame retardant acc.to DIN VDE 0482 part /EN /IEC Applications: Power and control use outdoor and indoor applications, even wet. Suitable for fixed installation at open air, in tube or canals, masonry, metals structures, overhead wire and for direct and indirect undergrround wiring. The most important property of this kind of cable is its protection against smokes, toxic and corrosive gases in case of fire G83020M15 2 x 1,5 12, G83020M25 2 x 2,5 13, G83020M40 2 x 4 14, G83020M60 2 x 6 15, G83020M61 2 x 10 18, G83020M62 2 x 16 20, G83020M63 2 x 25 25, G83020M64 2 x 35 27, G83020M65 2 x 50 30, G83020M66 2 x 70 36, / G83020M67 2 x / G83020M68 2 x , / G83020M69 2 x , G82031M15 3 G 1, G82031M25 3 G 2, G82031M40 3 G G82031M60 3 G G82031M61 3 G 10 19, G82031M62 3 G 16 33, G82031M63 3 G 25 26, G82031M64 3 G 35 29, G82031M65 3 G 50 32, G82031M66 3 G 70 38, / G82031M67 3 G / G82031M68 3 G , / G82031M69 3 G , G82031M70 3 G G82031M71 3 G ,

26 LOW VOLTAGE CABLES FG7(O)H1R 0,6/1 kv 46080G82041M15 4 G 1,5 13, G82041M25 4 G 2,5 14, G82041M40 4 G G82041M60 4 G 6 17, G82041M61 4 G 10 20, G82041M62 4 G 16 24, G82041M63 4 G 25 28, G83035M64 3 x x G83035M65 3 x x 25 34, G83035M66 3 x x / G83035M67 3 x x 50 45, / G83035M68 3 x x 70 53, / G83035M69 3 x x G83035M70 3 x x 95 62, G83035M71 3 x x , G82051M15 5 G 1, G82051M25 5 G 2, G82051M40 5 G 4 17, G82051M60 5 G 6 18, G82051M61 5 G 10 23, G82051M62 5 G G82051M63 5 G 25 31, G80071M15 7 G 1,5 15, G80071M25 7 G 2, G80101M15 10 G 1,5 17, G80101M25 10 G 2,5 19, G80121M15 12 G 1,5 19, G80121M25 12 G 2, G80161M15 16 G 1, G80161M25 16 G 2, G80191M15 19 G 1,5 24, G80191M25 19 G 2,5 28, Other dimensions and colours available on request. 17

27 LOW VOLTAGE CABLES FG7OH2R 0,6/1 kv Conductor: Insulation: flexible red copper conductor Cl.5, acc.to IEC Rubber,type G7 Nominal voltage: Test voltage: 600/1000 V 2,5 kv Colour core: Inner sheat: Screen: Outer sheath: DIN VDE 0293,HD 308 S2 thermoplastic compound red copper braid grey RAL (7035), PVC,type Rz Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: - 25 o C / + 90 o C 0 o C / + 90 o C + 90 o C o C Features: according to IEC Min. bending radius: Max. tensile stress: Resistance: 8 x d 5 kg x mm 2 Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Oil resistant acc. to: IEC , DIN VDE 0473 part POWER 46090G8L010M40 1x G8L010M60 1x6 7, G8L010M61 1x10 9, G8L010M62 1x16 10, G8L010M63 1x G8L010M64 1x35 14, G8L010M65 1x50 16, G8L010M66 1x70 17, / G8L010M67 1x / G8L010M68 1x / G8L010M69 1x MCM 46090G8L010M70 1x185 29, MCM 46090G8L010M71 1x MCM 46090G8L010M72 1x MCM 46090G8L010M73 1x MCM 46090G8L010M74 1x MCM 46090G8L010M75 1x MCM 46090G83020M15 2x1,5 12,5 28, G83020M25 2x2,5 13,5 47, G83020M40 2x , G83020M60 2x , G83020M61 2x G83020M62 2x16 20,5 307, G83020M63 2x G83020M64 2x35 26, G83020M65 2x50 30, G82031M15 3G1,5 13,5 43, G82031M25 3G2,5 14, G82031M40 3G4 15,5 115, G82031M60 3G , G82031M61 3G

28 LOW VOLTAGE CABLES FG7OH2R 0,6/1 kv 46090G82031M62 3G16 21, G82031M63 3G25 25, G82031M64 3G35 28, G82031M65 3G50 32, G82031M66 3G / G82031M67 3G / G82031M68 3G / G82031M69 3G MCM 46090G82041M15 4G , G82041M25 4G2.5 15, G82041M40 4G4 16,5 153, G82041M60 4G6 18,5 230, G82041M61 4G G82041M62 4G16 23,5 614, G82041M63 4G G82035M64 3x , G82035M65 3x , G82035M66 3x , / G82035M67 3x , / G82035M68 3x , / G82035M69 3x , MCM 46090G82051M15 5G1.5 15, G82051M25 5G2.5 16, G82051M40 5G4 18, G82051M60 5G6 19, G82051M61 5G10 22, G82051M62 5G16 25, G82051M63 5G25 30, G82051M64 5G35 34, G82051M65 5G50 39, Other dimensions and colours available on request. CONTROL No,of cores ca,mm approx, no,*) 46090G80071M15 7G1,5 16,1 100, G80101M15 10G1,5 19, G80121M15 12G1,5 20,2 172, G80161M15 16G1,5 22,0 230, G80191M15 19G1,5 23,0 273, G80241M15 24G1,5 26,4 345, G80071M25 7G2,5 17, G80101M25 10G2,5 21, G80121M25 12G2,5 22, G80161M25 16G2,5 24, G80191M25 19G2,5 25, G80241M25 24G2,5 29, Other dimensions and colours available on request. 19

29 LOW VOLTAGE CABLES N1VC7V-K Conductor: Insulation: Colour core: Filler: Screen: Outer sheath: flexible red copper, Cl.5, acc. to IEC PVC, type R2 2 cores: blue-brown, 3 cores: brown-black-gray (or blue-brown-y/g), 4 cores: blue-brown-black-gray (or Y/G instead blue). 5 cores: Y/G-blue-brown-black-gray (or black instead Y/G), Multicores: black with numbers. not fibrous and hygroscopic materials Two alternated copper tapes light blue (RAL 5012), PVC, type R2 Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: 0 o C / + 70 o C Max. short circuit temperature: 160 o C Min. bending radius: 8 x D Tensile stress: Installation: 50 n/mm 2 Static stress: 15 n/mm 2 Features: Indoor and outdoor use acc. to I UNEL TABLE Resistance: Flame retardant acc. to: IEC C, DIN VDE 0482 part EN GB3020M15 2x1,5 13,4 28, GB3020M25 2x2,5 14, GB3020M40 2x4 16,3 28, GB3020M60 2x6 17, GB3020M61 2x10 19,3 76, GB3020M62 2x16 22,8 115, GB3020M63 2x25 27, GB2031M15 3G1,5 13, GB2031M25 3G2,5 15, GB2031M40 3G4 16, GB2031M60 3G6 18, GB2031M61 3G10 20, GB2031M62 3G16 24, GB2031M63 3G25 28, GB2041M15 4G1,5 14,6 57, GB2041M25 4G2,5 16, GB2041M40 4G4 18,0 153, GB2041M60 4G6 19,3 230,

30 LOW VOLTAGE CABLES GAALFLEX VFD FG7(O)CR inverter, connection to frequency converters Conductor: flexible red copper conductor Cl.5, acc.to IEC Insulation: rubber,type G7 Cores colour: brown - grey - black Stranding: cores laying to concentric crowns to ensure roundness to the cable. Inner sheath: PVC,type R2 Screen: red copper braid of the same section as the phase conductor (for sections up to 16 mm 2 ) or equal to half phase conductor, with a minimum of 16 mm2 (for section greater than 25 mm 2 ) Outer sheath: grey (RAL 7001),PVC,type Rz Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: fixed laying: - 50 o C / + 80 o C flexible application: -35 o C / + 80 o C Temperaure at conductor: in service: + 90 C in short circuit: C Min. bending radius: 8 x d Features: according to IEC and I 20-13, I-UNEL Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN / IEC Current capacity at 30 C 33190G83030M25 3x2,5+SH 14, G83030M40 3x4+SH 15, G83030M60 3x6+SH 18, G83030M61 3x10+SH 21, G83030M62 3x16+SH 25, G83030M63 3x25+SH 28, G83030M64 3x35+SH 32, G83030M65 3x50+SH 36, G83030M66 3x70+SH 40, / G83030M67 3x95+SH 47, / G83030M68 3x120+SH 52, / G83030M69 3x150+SH 56, MCM 33190G83030M70 3x185+SH 64, MCM 33190G83030M71 3x240+SH 74, MCM 33190G83030M72 3x300+SH 85, MCM Temperature C: K Factor: ,17 1,12 1,06 0,94 0,87 0,79 0,71 0,61 0,50 Other dimension and colours available on request. 21

31 LOW VOLTAGE CABLES GAALFLEX VFD FG7OHH2R 0,6/1 KV inverter,connection to frequency converters Conductor: flexible red copper conductor Cl.5, acc.to IEC Insulation: rubber,type G7 Colour core: brown - grey - black Screen: aluminium stripe (100% covering), red copper braid of the same section as the phase conductor (for sections up to 16 mm 2 ) or equal to half phase conductor, with a minimum of 16 mm 2 (for section greater than 25 mm 2) ) Outer sheath: grey (RAL 7001),PVC,type Rz Features: according to IEC and I 20-13, I-UNEL Nominal voltage: Test voltage: 600/1000 kv 4 kv Temperature range: Fixed installation: -50 C / + 80 C Flexible installation: -35 C / + 80 C Temperaure at conductor: in service: + 90 C in short circuit: C Min. bending radius: 8 x d Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC , I 20-22/II No,of cores ca,mm Current capacity at 30 C approx, no,*) 33170G83030M25 3x2,5+SH 14, G83030M40 3x4+SH 15, G83030M60 3x6+SH 18, G83030M61 3x10+SH G83030M62 3x16+SH 23, G83030M63 3x25+SH G83030M64 3x35+SH 30, G83030M65 3x50+SH G83030M66 3x70+SH / G83030M67 3x95+SH / G83030M68 3x120+SH / G83030M69 3x150+SH 55, MCM 33170G83030M70 3x185+SH 61, MCM 33170G83030M71 3x240+SH MCM 33170G83030M72 3x300+SH 85, MCM Temperature C: K Factor: ,17 1,12 1,06 0,94 0,87 0,79 0,71 0,61 0,50 Other dimensions and colors available on request. Possible on request: FG7OHH2M1-0,6/1 kv, Halogen free Version Sheath: green M1 LSOH thermoplastic 22

32 LOW VOLTAGE CABLES FG7(O)NR 0.6/1 kv Conductor: Insulation: Cores colour: Inner sheat: Armour: Outer sheath: flexible red copper conductor Cl.5, acc.to IEC rubber,type G7 1 core: black 2 cores: blue-brown, 3 cores: brown-black-gray (or blue-brown-y/g), 4 cores: blue-brown-black-gray (or Y/G without blue). 5 cores: Y/G-blue-brown-black-gray (or black without Y/G), Multicores: black with numbers PVC,type RZ steel tapes light grey (RAL 7035),PVC,type RZ Features: Nominal voltage: Test voltage: Temperature range: Temperature at conductor: in service: in short circuit: Min. bendiung radius: Resistance: 600/1000 kv 4 kv 0 o C to + 70 o C + 90 o C o C 14 x D Flame retardant and self-extinguishing: DIN VDE 0482 part , EN , IEC Low smoke emission acc. to: IEC , EN DIN VDE 0482 part according to IEC G83020M15 2x1,5 13,5 28, G83020M25 2x2,5 14, G83020M40 2x4 15,6 76, G83020M60 2x6 16,6 115, G83020M61 2x10 19, G83020M62 2x16 21,5 307, G83020M63 2x25 26, G83020M64 2x35 28, G83020M65 2x50 31, G83020M66 2x70 37, G83020M67 2x95 40, G83020M68 2x120 47, G83020M69 2x150 54, G82031M15 3G1, , G82031M25 3G2, G82031M40 3G , G82031M60 3G6 17,2 172, G82031M61 3G10 20, G82031M62 3G16 23,4 460, G82031M63 3G25 27, G82031M64 3G35 30, G82031M65 3G50 33, G82031M66 3G70 39, G82031M67 3G95 45, G82031M68 3G120 53, G82031M69 3G G82031M70 3G185 61, G82031M71 3G240 71, G83035M64 3x35+1x25 32, G83035M65 3x50+1x25 35, G83035M66 3x70+1x35 41, G83035M67 3x95+1x70 47, G83035M68 3x120+1x70 55, G83035M69 3x150+1x95 60, G83035M70 3x185+1x95 64, G83035M71 3x240+1x150 74, G82041M15 4G1,5 14,8 57, G82041M25 4G2,5 15, G82041M40 4G4 17,2 153, G82041M60 4G6 18,5 230, G82041M61 4G G82041M62 4G16 25,8 614, G82041M63 4G25 29,

33 LOW VOLTAGE CABLES FG7(O)NR 0.6/1 kv 46110G82051M15 5G1, G82051M25 5G2, G82051M40 5G4 18, G82051M60 5G G82051M61 5G10 24, G82051M62 5G16 27, G82051M63 5G25 32, G80071M15 7G1,5 16,7 100, G80071M25 7G2,5 18, G80101M15 10G1,5 18, G80101M25 10G2,5 20, G80121M15 12G1,5 20,4 172, G80121M25 12G2,5 22, G80161M15 16G1, , G80161M25 16G2, G80191M15 19G1,5 23,7 273, G80191M25 19G2, G80241M15 24G1,5 26,6 345, G80241M25 24G2,5 29, Other dimensions and colours available on request. 24

34 LOW VOLTAGE CABLES FG7(O)RAR 0.6/1 kv Conductor: flexible red copper conductor Cl.5, acc.to IEC Nominal voltage: 600/1000 V Insulation: rubber,type G7 Test voltage: 4 kv Colour core: Armour: Outer sheath: 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores: Y/G-black-light blue-brown-black braid of galvanized steel wires light grey (RAL 7035),PVC,type RZ Features: Temperature range: fixed laying: flexible application: Min. Bending Radius: Temperature at conductor: in service: in short circuit: Resistance: - 25 o C / + 90 o C 0 o C / + 90 o C 8 x d + 90 o C o C Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC according to IEC G83020M15 2x1,5 10,3 28, G82031M15 3G1,5 10, G82041M15 4G1,5 11,6 57, G82051M15 5G1,5 12, G80071M15 7G1,5 13,4 100, G80101M15 10G1,5 16, G80121M15 12G1,5 17,2 172, G80161M15 16G1,5 19,1 230, G80191M15 19G1,5 20,2 273, G80241M15 24G1,5 22,8 345, G80301M15 30G1,5 24, G80361M15 36G1,5 26,7 518, G80481M15 48G1,5 30,3 691, G83020M25 2x2,5 11, G82031M25 3G2,5 12, G82041M25 4G2,5 12, G82051M25 5G2,5 14, G80071M25 7G2,5 15, G80101M25 10G2,5 18, G80121M25 12G2,5 19, G80161M25 16G2,5 21, G80191M25 19G2,5 23, G80241M25 24G2,5 26, G80301M25 30G2,5 28, G80361M25 36G2,5 30, G83020M40 2x4 12,7 76, G82031M40 3G4 13,3 115, G82041M40 4G4 14,7 153, G82051M40 5G4 15, G80071M40 7G4 17,4 268, G80101M40 10G4 21, G80121M40 12G4 22,5 460, G80161M40 16G4 25,1 614, G80191M40 19G4 26,4 729, Other dimensions and colours available on request. 25

35 LOW VOLTAGE CABLES FG7(O)RAR 0.6/1 kv 46120G83020M60 2x6 14,2 115, G82031M60 3G6 14,9 172, G82041M60 4G6 16,2 230, G82051M60 5G6 17, G80071M60 7G6 19,3 403, G80101M60 10G6 24, G80121M60 12G6 25,4 691, G80161M60 16G6 28,1 921, G83020M61 2x10 16, G82031M61 3G10 17, G82041M61 4G10 19, G82051M61 5G10 21, G83020M62 2x16 18,9 307, G82031M62 3G16 20,0 460, G82041M62 4G16 21,8 614, G83020M63 2x25 22, G82031M63 3G25 24, G82041M63 4G25 26, Other dimensions and colours available on request. 26

36 LOW VOLTAGE CABLES FG7(O)H2RAR 0.6/1 kv Conductor: flexible red copper conductor Cl.5, acc.to IEC Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: 600/1000 V 4 kv Insulation: Colour core: Screen: Inner sheath: Armour: Outer sheath: rubber,type G7 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores: Y/G-black-light blue-brown-black red copper braid PVC compound braid of galvanized steel wires light grey (RAL 7035),PVC,type RZ Temperature at conductor: in service: in short circuit: Min. Bending Radius: Resistance: - 25 o C / + 90 o C 0 o C / + 90 o C + 90 o C o C 8 x d Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Features: according to IEC No,of cores ca,mm approx, no,*) 46130G83020M15 2x1,5 16,1 28, G82031M15 3G1,5 17,1 30, G82041M15 4G1,5 17,6 57, G82051M15 5G1,5 18, G80071M15 7G1,5 19,7 100, G80101M15 10G1,5 23, G80121M15 12G1,5 23,8 172, G80161M15 16G1,5 25,6 230, G80191M15 19G1,5 26,6 273, G80241M15 24G1, , G80301M15 30G1, G80361M15 36G1,5-518, G80481M15 48G1,5-691, G83020M25 2x2,5 16, G82031M25 3G2,5 17, G82041M25 4G2,5 19, G82051M25 5G2, G80071M25 7G2,5 21, G80101M25 10G2,5 25, G80121M25 12G2,5 25, G80161M25 16G2,5 27, G80191M25 19G2, G80241M25 24G2,5 32, G80301M25 30G2, G80361M25 36G2, G83020M40 2x4 18,6 76, G82031M40 3G4 19,1 115, G82041M40 4G4 19,5 153, G82051M40 5G4 21, G80071M40 7G4-268, G80101M40 10G G80121M40 12G G80161M40 16G G80191M40 19G G83020M60 2x6 19,6 115, G82031M60 3G6 20,6 172, G82041M60 4G6 22, G82051M60 5G6 23, G80071M60 7G6-403, G80101M60 10G G80121M60 12G6-691, G80161M60 16G6-921, G83020M61 2x10 64, G82031M61 3G10 68, G82041M61 4G10 24, G82051M61 5G10 34, G83020M62 2x16 24,1 307, G82031M62 3G16 25,1 460, G82041M62 4G16 27,1 614, G83020M63 2x25 17, G82031M63 3G25 18, G82041M63 4G25 31, G82041M64 4G G82041M65 4G G82041M66 4G / G82041M67 4G / G82041M68 4G / G82041M69 4G MCM Other dimensions and colours available on request. 27

37 LOW VOLTAGE CABLES FG7(O)HH2RAR 0.6/1 kv Conductor: Insulation: Colour core: Screen: Inner sheat: Armour Outer sheat: flexible red copper conductor Cl.5, acc.to IEC rubber HEPR 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light blue) 4 cores: light blue-brown-black-black, 5 cores: Y/G-black-light blue-brown-black aluminium tape and red copper braid PVC compound braid of galvanized steel wires light grey (RAL 7035),PVC,type RZ Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: Min. Bending Radius: Resistance: 600/1000 V 4 kv - 25 o C / + 90 o C 0 o C / + 90 o C + 90 o C o C 8 x d Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Features: according to IEC G83020M15 2x1,5 16,1 28, G82031M15 3G1,5 17,1 30, G82041M15 4G1,5 17,6 57, G82051M15 5G1,5 18, G80071M15 7G1,5 19,7 100, G80101M15 10G1,5 23, G80121M15 12G1,5 23,8 172, G80161M15 16G1,5 25,6 230, G80191M15 19G1,5 26,6 273, G80241M15 24G1, , G80301M15 30G1, G80361M15 36G1,5-518, G80481M15 48G1,5-691, G83020M25 2x2,5 16, G82031M25 3G2,5 17,1 30, G82041M25 4G2,5 19, G82051M25 5G2, G80071M25 7G2,5 21, G80101M25 10G2,5 25, G80121M25 12G2,5 25, G80161M25 16G2,5 27, G80191M25 19G2, G80241M25 24G2,5 32, G80301M25 30G2, G80361M25 36G2, G83020M40 2x4 18,6 76, G82031M40 3G4 19,1 115, G82041M40 4G4 19,5 153, G82051M40 5G4 21, G80071M40 7G4-268, G80101M40 10G G80121M40 12G4-460, G80161M40 16G4-614, G80191M40 19G4-729,

38 LOW VOLTAGE CABLES FG7(O)HH2RAR 0.6/1 kv 46140G83020M60 2x6 19,6 115, G82031M60 3G6 20,6 172, G82041M60 4G6 22, G82051M60 5G6 23, G80071M60 7G6-403, G80101M60 10G G80121M60 12G6-691, G80161M60 16G6-921, G83020M61 2x10 64, G82031M61 3G10 68, G82041M61 4G10 24, G82051M61 5G10 34, G83020M62 2x16 24,1 307, G82031M62 3G16 25,1 460, G82041M62 4G16 27,1 614, G83020M63 2x25 17, G82031M63 3G25 18, G82041M63 4G25 31, G82041M64 4G G82041M65 4G G82041M66 4G / G82041M67 4G / G82041M68 4G / G82041M69 4G Other dimensions and colours available on request. 29

39 LOW VOLTAGE CABLES GAALFLEX CONTROL 1000 BH halogen-free, control cable with coloured cores 0,6/1 kv Conductor: Insulation: Colour core: Wrapping: Outer sheath: flexible red copper conductor Cl.5, acc.to IEC halogen-free compound 1 core: black 2 cores: blue, brown 3 cores: brown, black, gray (or blue brown. Y/G) 4 cores: blue, brown, black, gray, (or Y/G instead blue) 5 cores: blue. brown. black. gray. Y/G Multi cores: black with numbers filler compound gray (RAL 7001), halogen-free compound Features: I / III (EN 50266) / (EN ) (EN 50267) / UNEL TABLES small bending radius Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: Fixed installation: -40 C up to 90 C Flexible application: -15 C up to 90 C Short circuit: C Min. bending radius: Fixed laying: 4 x d Flexible installation: 6 x d Max. pulling installation: During installation: 50 N/mm 2 Static stress: 15 N/mm 2 Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Halogen-free: acc. to DIN VDE 0482 part 267, EN / IEC (equivalent DIN VDE 0472 part 815) Low smoke density: acc. to IEC , DIN VDE 0482 part , EN Corrosivenes of conflagration gases: acc. to DIN VDE 0482 part 267/ EN / IEC (equivalent DIN VDE 0472 part 813) POWER Part no No. of cores Ca. mm weig ht 31260G53020M15 2 x 1, , G53020M25 2 x 2,5 10, G53020M40 2 x 4 11,9 76, G53020M60 2 x 6 13,1 115, G53020M61 2 x 10 15,3 192, G53020M62 2 x 16 17,5 307, G53020M63 2 x 25 20, G53020M64 2 x 35 22, G53020M65 2 x 50 26, G53020M66 2 x 70 30, / G53020M67 2 x 95 34, / G53020M68 2 x , / G53020M69 2 x , MCM 31260G52031M15 3 G 1,5 10,4 43, G52031M25 3 G 2,5 11, G52031M40 3 G 4 12,8 115, G52031M60 3 G 6 13,8 172, G52031M61 3 G 10 16, G52031M62 3 G 16 18,2 460, G52031M63 3 G 25 21, G52031M64 3 G 35 23, G52031M65 3 G 50 29, G52031M66 3 G / G52031M67 3 G /0 30

40 LOW VOLTAGE CABLES GAALFLEX CONTROL 1000 BH halogen-free, control cable with coloured cores 0,6/1 kv No, of cores Ca. mm 31260G52031M68 3 G , / G52031M69 3 G , MCM 31260G52031M70 3 G , MCM 31260G52031M71 3 G ,4 6912, MCM 31260G52031M72 3 G ,7 8640, MCM 31260G52041M15 4 G 1,5 10,9 57, G52041M25 4 G 2,5 12,3 96, G52041M40 4 G 4 13,7 153, G52041M60 4 G , G52041M61 4 G , G52041M62 4 G 16 20,3 614, G52041M63 4 G 25 23,5 960, G52035M64 3 x G 25 26,3 1248, G52035M65 3 x G 25 30,3 1680, G52035M66 3 x 70+1 G 35 35,7 2352, / G52035M67 3 x G 50 41,2 3216, / G52035M68 3 x G , / G52035M69 3 x G , MCM 31260G52035M70 3 x G 95 56,7 6240, MCM 31260G52035M71 3 x G ,6 8352, MCM 31260G52035M72 3 x G , MCM 31260G52051M15 5 G 1,5 12,1 72, G52051M25 5 G 2,5 13,5 120, G52051M40 5 G 4 15,2 196, G52051M60 5 G 6 16,7 288, G52051M61 5 G 10 19,7 480, G52051M62 5 G 16 22,5 768, G52051M63 5 G 25 26,5 1200, G52051M64 5 G 35 32,9 1680, G52051M65 5 G 50 38,3 2400, CONTROL No. of cores Ca. mm 31260G50071M15 7 G1,5 13,6 100, G50071M25 7 G 2, , G50071M25 10 G 1,5 15,2 144, G50071M25 10 G 2,5 15,0 240, G50121M15 12 G 1,5 17,2 172, G50121M25 12 G 2,5 17,6 288, G50121M25 16 G 1,5 18,5 230, G50121M25 16 G 2,5 21,5 384, G50191M25 19 G 1,5 18,8 273, G50191M25 19 G 2,5 21,6 456, G50241M25 24 G 1,5 21,7 324, G50241M25 24 G 2,5 24,7 576, G50271M25 27 G 1, G50271M25 27 G 2,5 26, G50301M25 30 G 1,5 24, G50301M25 30 G 2,5 27, Other dimension and colours available on request. 31

41 LOW VOLTAGE CABLES FG7(O)M1 0,6/1 kv Conductor: Insulation: Colour core: Inner sheath: Outer Sheath: flexible red copper conductor Cl.5, acc.to IEC rubber,type G7 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores: Y/G-black-light blue-brown-black Thermoplastic,halogen free compound green (RAL 6018),thermoplastic,halogen-free,type M1 Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: Min. bending radius: POWER: CONTROL: Max. tensile stress: 600/1000 V 3,5 kv -40 C up to 90 C -15 C up to 90 C + 90 o C o C 4 x d 6 x d 5 kg x mm 2 Features: according to IEC Resistance: Flame retardant and self-extinguishin acc. to: DIN VDE 0482 part , EN , IEC Halogen free acc. to: EN ,IEC DIN VDE 0482 part POWER 46150GEL010M61 1x10 9, GEL010M62 1x16 10,4 153, GEL010M63 1x25 12, GEL010M64 1x35 13, GEL010M65 1x50 15, GEL010M66 1x70 17, / GEL010M67 1x95 19, / GEL010M68 1x120 21, / GEL010M69 1x150 23, MCM 46150GEL010M70 1x185 26, MCM 46150GEL010M71 1x240 29, MCM 46150GEL010M72 1x300 32, MCM 32

42 LOW VOLTAGE CABLES FG7(O)M1 0,6/1 kv 46150GE3020M15 2x1,5 12,0 28, GE3020M25 2x2,5 13, GE3020M40 2x4 14,2 76, GE3020M60 2x6 15,4 115, GE3020M61 2x10 17, GE3020M62 2x16 19,4 307, GE3020M63 2x25 23, GE3020M64 2x35 25, GE3020M65 2x50 29, GE3020M66 2x70 33, / GE3020M67 2x95 37, / GE3020M68 2x120 41, / GE3020M69 2x150 46, MCM 46150GE2031M15 3G1,5 12,5 43, GE2031M25 3G2,5 13, GE2031M40 3G4 14,9 115, GE2031M60 3G6 16,2 172, GE2031M61 3G10 18, GE2031M62 3G16 20,6 460, GE2031M63 3G25 24, GE2031M64 3G35 27, GE2031M65 3G50 31, GE2031M66 3G70 35, / GE2031M67 3G95 40, / GE2031M68 3G120 44, / GE2031M69 3G150 49, MCM 46150GE2031M70 3G185 55, MCM 46150GE2031M71 3G240 61, MCM 46150GE2031M72 3G300 68, MCM 46150GE2041M15 4G1,5 13,4 57, GE2041M25 4G2,5 14, GE2041M40 4G4 16,0 153, GE2041M60 4G6 17,5 230, GE2041M61 4G10 19, GE2041M62 4G16 22,4 614, GE2041M63 4G25 26, GE2035M64 3x , GE2035M65 3x , GE2035M66 3x , / GE2035M67 3x , / GE2035M68 3x , / GE2035M69 3x , MCM 46150GE2035M70 3x , MCM 46150GE2035M71 3x , MCM 46150GE2035M72 3x , MCM 46150GE2051M15 5G1,5 14, GE2051M25 5G2,5 15, GE2051M40 5G4 17, GE2051M60 5G6 18, GE2051M61 5G10 21, GE2051M62 5G16 24, GE2051M63 5G25 29, GE2051M64 5G35 32, GE2051M65 5G50 38, Other dimensions and colours available on request. CONTROL Part no, No,of cores ca,mm approx, no,*) Part no, No,of cores ca,mm approx, no,*) 46150GE0071M15 7G1,5 15,4 100, GE0101M15 10G1,5 18, GE0121M15 12G1,5 19,3 172, GE0161M15 16G1,5 21,1 230, GE0191M15 19G1,5 22,1 273, GE0241M15 24G1,5 25,4 345, GE0071M25 7G2,5 16, GE0101M25 10G2,5 20, GE0121M25 12G2,5 21, GE0161M25 16G2,5 23, GE0191M25 19G2,5 24, GE0241M25 24G2,5 28, Other dimensions and colours available on request. 33

43 LOW VOLTAGE CABLES FG7(O)H2M1 0,6/1kV Conductor: Insulation: flexible red copper conductor Cl.5, acc.to IEC rubber,type G7 Nominal voltage: Test voltage: 600/1000 V 3,5 kv Colour core: Inner sheath: Screen: Outer sheat: 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores: Y/G-black-light blue-brown-black Thermoplastic,halogen free compound red copper braid green (RAL 6018),thermoplastic,halogen-free,type M1 Features: According to IEC Min. bending radius: Temperature range: fixed laying: flexible application: Temperature range: Fixed installation Flexible installation: Max. tensile stress: Resistance: 8 x d - 40 o C / +90 o C - 15 o C / +90 o C + 90 o C o C 5 kg x mm 2 Flame retardant and self-extinguishin acc. to: DIN VDE 0482 part , EN , IEC Halogen free acc. to: EN ,IEC DIN VDE 0482 part POWER 46160GE3020M15 2x1,5 12,7 28, GE3020M25 2x2,5 13,7 47, GE3020M40 2x4 14,9 76, GE3020M60 2x6 16,1 115, GE3020M61 2x10 18, GE3020M62 2x16 20,4 307, GE3020M63 2x25 24, GE3020M64 2x35 26, GE3020M65 2x50 30, GE3020M66 2x70 34,3 43, / GE3020M67 2x95 38, / GE3020M68 2x120 43,0 115, / GE3020M69 2x150 47,5 172, MCM 46160GE2031M15 3G1,5 13, GE2031M25 3G2,5 14,3 43, GE2031M40 3G4 15, GE2031M60 3G6 16,9 115, GE2031M61 3G10 19,2 172, GE2031M62 3G16 21, GE2031M63 3G25 25, GE2031M64 3G35 28, GE2031M65 3G50 32, GE2031M66 3G70 36, / GE2031M67 3G95 41, / GE2031M68 3G120 45, / GE2031M69 3G150 50, MCM 46160GE2031M70 3G185 56, MCM 34

44 LOW VOLTAGE CABLES FG7(O)H2M1 0,6/1kV No,of cores ca,mm approx, no,*) 46160GE2031M71 3G240 63, MCM 46160GE2031M72 3G300 69, MCM 46160GE2041M15 4G1,5 14,1 57, GE2041M25 4G2,5 15, GE2041M40 4G4 16,7 153, GE2041M60 4G6 18,4 230, GE2041M61 4G10 20, GE2041M62 4G16 23,4 614, GE2041M63 4G25 27, GE2035M64 3x , GE2035M65 3x , GE2035M66 3x , / GE2035M67 3x , / GE2035M68 3x , / GE2035M69 3x , MCM 46160GE2035M70 3x , MCM 46160GE2035M71 3x , MCM 46160GE2035M72 3x , MCM 46160GE2051M15 5G1,5 15, GE2051M25 5G2,5 16, GE2051M40 5G4 18, GE2051M60 5G6 19, GE2051M61 5G10 22, GE2051M62 5G16 25, GE2051M63 5G25 30, GE2051M64 5G35 34, GE2051M65 5G50 39, Other dimensions and colours available on request. CONTROL 46160GE0071M15 7G1,5 16,1 100, GE0101M15 10G1,5 19, GE0121M15 12G1,5 20,2 172, GE0161M15 16G1,5 22,0 230, GE0191M15 19G1,5 23,0 273, GE0241M15 24G1,5 26,4 345, GE0071M25 7G2,5 17, GE0101M25 10G2,5 21, GE0121M25 12G2,5 22, GE0161M25 16G2,5 24, GE0191M25 19G2,5 25, GE0241M25 24G2,5 29, Other dimensions and colours available on request. 35

45 LOW VOLTAGE CABLES FG7(O)AM1 0,6/1kV Conductor: Insulation: Inner sheath: Armour: Outer sheat: flexible red copper conductor Cl.5, acc.to IEC rubber,type G7 Thermoplastic,halogen free compound braid of galvanized steel wires green (RAL 6018),thermoplastic,halogen-free,type M1 Nominal voltage: Test voltage: Min. bending radius: Temperature range: fixed laying: flexible application: 600/1000 V 3,5 kv 8 x d - 40 o C / +90 o C - 15 o C / +90 o C Features: Temperature at conductor: in service: in short circuit: + 90 o C o C according to IEC Max. tensile stress: 5 kg x mm 2 Resistance: Flame retardant and self-extinguishin acc. to: DIN VDE 0482 part , EN , IEC Halogen free acc. to: EN ,IEC DIN VDE 0482 part POWER Part no, No,of cores ca,mm approx, no,*) 46170GE3020M15 2x1,5 12,7 28, GE3020M25 2x2,5 13, GE3020M40 2x4 14,9 76, GE3020M60 2x6 16,1 115, GE3020M61 2x10 18, GE3020M62 2x16 20,4 307, GE3020M63 2x25 24, GE3020M64 2x35 26, GE3020M65 2x50 30, GE3020M66 2x70 34, / GE3020M67 2x95 38, / GE3020M68 2x120 43, / GE3020M69 2x150 47, MCM 46170GE2031M15 3G1,5 13,3 43, GE2031M25 3G2,5 14, GE2031M40 3G4 15,6 115, GE2031M60 3G6 16,9 172, GE2031M61 3G10 19, GE2031M62 3G16 21,5 460, GE2031M63 3G25 25, GE2031M64 3G35 28, GE2031M65 3G50 32, GE2031M66 3G70 36, / GE2031M67 3G95 41, / GE2031M68 3G120 45, / GE2031M69 3G150 50, MCM 46170GE2031M70 3G185 56, MCM 36

46 LOW VOLTAGE CABLES FG7(O)AM1 0,6/1kV Part no, No,of cores ca,mm approx, no,*) 46170GE2031M71 3G240 63, MCM 46170GE2031M72 3G300 69, MCM 46170GE2041M15 4G1,5 14,1 57, GE2041M25 4G2,5 15,3 57, GE2041M40 4G4 16,7 153, GE2041M60 4G6 18, GE2041M61 4G10 20, GE2041M62 4G16 23,4 614, GE2041M63 4G25 27, GE2035M64 3x , GE2035M65 3x , GE2035M66 3x , / GE2035M67 3x , / GE2035M68 3x , / GE2035M69 3x , MCM 46170GE2035M70 3x , MCM 46170GE2035M71 3x , MCM 46170GE2035M72 3x , MCM 46170GE2051M15 5G1,5 15, GE2051M25 5G2,5 16, GE2051M40 5G4 18, GE2051M60 5G6 19, GE2051M61 5G10 22, GE2051M62 5G16 25, GE2051M63 5G25 30, GE2051M64 5G35 34, GE2051M65 5G50 39, Other dimensions and colours available on request. CONTROL 46170GE0071M15 7G1,5 16,1 100, GE0101M15 10G1,5 19, GE0121M15 12G1,5 20,2 172, GE0161M15 16G1,5 22,0 230, GE0191M15 19G1,5 23,0 273, GE0241M15 24G1,5 26,4 345, GE0071M25 7G2,5 17, GE0101M25 10G2,5 21, GE0121M25 12G2,5 22, GE0161M25 16G2,5 24, GE0191M25 19G2,5 25, GE0241M25 24G2,5 29, Other dimensions and colours available on request. 37

47 LOW VOLTAGE CABLES NYY-J/O power cable 0,6/1 kv Conductor: solid or stranded red copper conductor Conductor: Insulation: Cl.1 or 2,acc. to IEC DIN VDE 0295 PVC,type DIV4 Sheath Colour core: material: acc. to DIN VDE 0293 part. 308 Stranding: Sheath colour: cores stranded concentrically Outer sheath: black (RAL 9005),PVC,type DMV5 Features: Ozone resistance UV resistance acc to IEC Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: 600/1000 V 4 kv -40 C / +70 C -5 C / +50 C Max permessible: 50 N/mm 2 Min.Bending Radius: Single core: 12 x d Multi core: 15 x d Higtest permessible voltage: - Direct current system 1,8 Kv - Alternating current system 1,4 Kv single-phase system - Both conductor insulated, 0,7 Kv sigle-phase system - One conductor earthed, 1,2 Kv three phase system - With concentric conductor 3,6 Kv and a cross-section of 240 mm 2 and above Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC j -type O-type No.of cores x cross section j -type O-type x cross section 46180G7P011M G7L010M40 1 x 4 re 9, G7P011M G7L010M60 1 x 6 re 9, G7P011M G7L010M61 1 x 10 re 10, G7P011M G7L010M62 1 x 16 re 11, G7P011M G7L010M63 1 x 25 rm 12, G7P011M G7L010M64 1 x 35 rm 13, G7P011M G7L010M65 1 x 50 rm 15, G7P011M G7L010M66 1 x 70 rm 16, / G7P011M G7L010M67 1 x 95 rm 19, / G7P011M G7L010M68 1 x 120 rm 20, / G7P011M G7L010M69 1 x 150 rm 22, MCM 46180G7P011M G7L010M70 1 x 185 rm 25, MCM 46180G7P011M G7L010M71 1 x 240 rm 28, MCM 46180G7P011M G7L010M72 1 x 300 rm 30, MCM 46180G7P011M G7L010M73 1 x 400 rm 34, MCM 46180G7P011M G7L010M74 1 x 500 rm 38, MCM 46180G7P011M G7L010M75 1 x 630 rm 43, MCM G73020M15 2 x 1,5 re 11, G73020M25 2 x 2,5 re 12, G73020M40 2 x 4 re 14, G73020M60 2 x 6 re 15, G73020M61 2 x 10 re 16, G73020M62 2 x 16 re 18, G73020M63 2 x 25 rm 23, G72031M G73030M15 3 x 1,5 re 11, G72031M G73030M25 3 x 2,5 re 12, G72031M G73030M40 3 x 4 re 14, G72031M G73030M60 3 x 6 re 15, G72031M G73030M61 3 x 10 re 17, G72031M G73030M62 3 x 16 re 19, G72031M G73030M63 3 x 25 rm 24, G72031M G73030M64 3 x 35 sm 25, G72031M G73030M65 3 x 50 sm 26, G72031M G73030M66 3 x 70 sm 30, / G72031M G73030M67 3x95 sm 34, / G72031M G73030M68 3x120 sm 37, / G72031M G73030M69 3x150 sm 40, MCM 46180G72031M G73030M70 3x185 sm 46, MCM 46180G72031M G73030M71 3x240 sm 51, MCM 38

48 LOW VOLTAGE CABLES NYY-J/O power cable 0,6/1 kv j -type Part no, O-type Part no, No,of cores ca,mm Alu approx, no,*) 46180G72035M G73035M63 3X25/16 rm/re 24, G72035M G73035M64 3x35/16 sm/re 26, G72035M G73035M65 3x50/25 sm/rm 29, G72035M G73035M66 3x70/35 sm/rm 32, / G72035M G73035M67 3x95/50 sm 38, / G72035M G73035M68 3x120/70 sm 41, / G72035M G73035M69 3x150/70 sm 46, MCM 46180G72035M G73035M70 3x185/95 sm 51, MCM 46180G72035M G73035M71 3x240/120 sm 58, MCM 46180G72035M G73035M72 3x300/150 sm 64, MCM 46180G72041M G73040M15 4x1,5 re 12, G72041M G73040M25 4x2,5 re 13, G72041M G73040M40 4x4 re 15, G72041M G73040M60 4x6 re 16, G72041M G73040M61 4x10 re 18, G72041M G73040M62 4x16 re 21, G72041M G73040M63 4x25 rm 26, G72041M G73040M64 4x35 sm 27, G72041M G73040M65 4x50 sm 30, G72041M G73040M66 4x70 sm 34, / G72041M G73040M67 4x95 sm 39, / G72041M G73040M68 4x120 sm 42, / G72041M G73040M69 4x150 sm 47, MCM 46180G72041M G73040M70 4x185 sm 52, MCM 46180G72041M G73040M71 4x240 sm 58, MCM 46180G72051M G73050M15 5x1,5 re 13, G72051M G73050M25 5x2,5 re 14, G72051M G73050M40 5x4 re 16, G72051M G73050M60 5x6 re 18, G72051M G73050M61 5x10 re 20, re: round conductor, single-wire rm: round conductor, multi-wire sm: stranded, sectional wire Other dimensions and colours available on request. 39

49 LOW VOLTAGE CABLES (N)AYY-J/O Aluminium power cable 0,6/1 kv Conductor: solid or stranded plain aluminium conductor Cl. 1 or 2, acc. to IEC 60228, DIN VDE 0295 Insulation: PVC,type DIV4 Colour core: acc. to DIN VDE 0293 part. 308 Stranding: cores stranded concentrically Outer sheath: black (RAL 9005),PVC,type DMV5 Applications: Power cables for energy supply are installed in open air, in underground, in water, indoors and in cable ducts, power station, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not to be expected. Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: fixed laying: -30 /+70 C flexible application: -5 /+70 C Max. permessible: 50 N/mm 2 Min. bending radius: 12 x d Highest permessible voltage: - Direct current system 1,8 kv - Alternating current systems single-phase system 1,4 kv - Both conductor insulated, single-phase system 0,7 kv - One conductor earthed, three phase systems 1,2 kv - With concentric conductor and a cross-section of 240 mm 2 and above 3,6 kv Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC j -type O-type Outer Ø Alu j -type O-type x cross section Outer Ø Alu 46190G7P011M G7L010M40 1x4 Re 9, G7P011M G7L010M60 1x6 Re 9, G7P011M G7L010M61 1x10 Re 10, G7P011M G7L010M62 1x16 Re 11,0 46, G7P011M G7L010M63 1x25 Rm 12,0 72, G7P011M G7L010M64 1x35 Rm 13,0 101, G7P011M G7L010M65 1x50 Rm 15, G7P011M G7L010M66 1x70 Rm 16, / G7P011M G7L010M67 1x95 Rm 19, / G7P011M G7L010M68 1x120 Rm 20, / G7P011M G7L010M69 1x150 Rm 22, MCM 46190G7P011M G7L010M70 1x185 Rm 25, MCM 46190G7P011M G7L010M71 1x240 Rm 28, MCM 46190G7P011M G7L010M72 1x300 Rm 30, MCM 46190G7P011M G7L010M73 1x400 Rm 34, MCM 46190G7P011M G7L010M74 1x500 Rm 38, MCM 46190G7P011M G7L010M75 1x630 Rm 43, MCM G73020M15 2x1,5 Re 11, G73020M25 2x2,5 Re 12, G73020M40 2x4 Re 14, G73020M60 2x6 Re 15, G73020M61 2x10 Re 16, G73020M62 2x16 Re 18, G73020M63 2x25 Rm 23, G72031M G73030M15 3x1,5 Re 11, G72031M G73030M25 3x2,5 Re 12, G72031M G73030M40 3x4 Re 14, G72031M G73030M60 3x6 Re 15, G72031M G73030M61 3x10 Re 17, G72031M G73030M62 3x16 Re 19, G72031M G73030M64 3x35 Sm 25, G72031M G73030M65 3x50 Sm 26, G72031M G73030M66 3x70 Sm 30, / G72031M G73030M67 3x95 Sm 34, / G72031M G73030M68 3x120 Sm 37, / G72031M G73030M69 3x150 Sm 40, MCM 46190G72031M G73030M70 3x185 Sm 46, MCM 46190G72031M G73030M71 3x240 Sm 51, MCM 46190G72035M G73035M63 3x25/16 Rm/Re 24, G72035M G73035M64 3x35/16 Rm/Re 26, G72035M G73035M65 3x50/25 Rm/Re 29,

50 LOW VOLTAGE CABLES (N)AYY-J/O Aluminium power cable 0,6/1 kv j -type O-type Outer Alu j -type O-type Outer Alu 46190G72035M G73035M66 3x70/35 Sm/Rm 32, / G72035M G73035M67 3x95/50 Sm 38, / G72035M G73035M68 3x120/70 Sm 41, / G72035M G73035M69 3x150/70 Sm 46, MCM 46190G72035M G73035M70 3x185/95 Sm 51, MCM 46190G72035M G73035M71 3x240/120 Sm 58, MCM 46190G72035M G73035M72 3x300/150 Sm 64, MCM 46190G72041M G73040M15 4x1.5 Re 12, G72041M G73040M25 4x2,5 Re 13, G72041M G73040M40 4x4 Re 15, G72041M G73040M60 4x6 Re 16, G72041M G73040M61 4x10 Re 18, G72041M G73040M62 4x16 Rm 21, G72041M G73040M63 4x25 Sm 26, G72041M G73040M64 4x35 Sm 27, G72041M G73040M65 4x50 Sm 30, G72041M G73040M66 4x70 Sm 34, / G72041M G73040M67 4x95 Sm 39, / G72041M G73040M68 4x120 Sm 42, / G72041M G73040M69 4x150 Sm 47, MCM 46190G72041M G73040M70 4x185 Sm 52, MCM 46190G72041M G73040M71 4x240 Re 58, MCM 46190G72051M G73050M15 5x1,5 RE 13, G72051M G73050M25 5x2,5 RE 14, G72051M G73050M40 5x4 RE 16, G72051M G73050M60 5x6 RE 18, G72051M G73050M61 5x10 RE 20, G72051M G73050M62 5x16 RE 22, G72051M G73050M63 5x25 RM 28, G72051M G73050M64 5x35 RM 34, G72051M G73050M65 5x50 RM 40, G70071M G71070M15 7x1,5 RE 15, G70071M G71070M25 7x2,5 RE 16, G70071M G71070M40 7x4 RE 18, G70071M G71070M60 7x6 RE 20, G70071M G71070M61 7x10 RE 23, G70101M G71100M15 10x1,5 RE 18, G70101M G71100M25 10x2,5 RE 19, G70121M G71120M15 12x1,5 RE 19, G70121M G71120M25 12x2,5 RE 20, G70141M G71140M15 14x1,5 RE 20, G70141M G71140M25 14x2,5 RE 21, G70161M G71160M15 16x1,5 RE 21, G70161M G71160M25 16x2,5 RE 22, G70191M G71190M15 19x1,5 RE 22, G70191M G71190M25 19x2,5 RE 23, G70211M G71210M15 21x1,5 RE 23, G70211M G71210M25 21x2,5 RE 24, G70241M G71240M15 24x1,5 RE 25, G70241M G71240M25 24x2,5 RE 27, G70301M G71300M15 30x1,5 RE 26, G70301M G71300M25 30x2,5 RE 28, G70401M G71400M15 40x1,5 RE 29, G70401M G71400M25 40x2,5 RE 31, G70521M G71520M25 52x2,5 RE 35, G70611M G71610M25 61x1,5 RE 34, Other dimensions and colours available on request. SOLID VERSION j-type O-type Alu 46191G72035M G73035M71 3x240/120 SE MCM 46191G72041M G73040M62 4x16 SE 23,0 186,0 750, G72041M G73040M63 4x25 SE 26,0GYU 290,0 950, G72041M G73040M64 4x35 SE 28,5 406,0 1120, G72041M G73040M65 4x50 SE 30,0 580,0 1151, G72041M G73040M66 4x70 SE 35,0 812,0 1549,0 2/ G72041M G73040M67 4x95 SE 39,5 1102,0 2030,0 3/ G72041M G73040M68 4x120 SE 44,0 1392,0 2400,0 4/ G72041M G73040M69 4x150 SE 46,0 1740,0 3030,0 250 MCM 46191G72041M G73040M70 4x185 SE 51,0 2146,0 3650,0 350 MCM 46191G72041M G73040M71 4x240 SE 56,0 2784,0 4800,0 450 MCM Other dimensions and colours available on request. 41

51 LOW VOLTAGE CABLES GAALFLEX NYCY Power cable with concentric copper conductor, 0.6/1 kv Conductor: solid red copper conductor Cl. 1 acc. to IEC 60228, DIN VDE 0295 Insulation: PVC,type DIV4 Colour core: acc. to DIN VDE 0293 part. 308 Stranding: cores stranded concentrically Inner sheath: filler compound Screen: red copper braid + red copper tape Outer sheath: black (RAL 9005),PVC,type DMV5 Features: Acc. to DIN VDE 0276 part 603.1, HD 603 S1 and IEC cores and above cc. to DIN VDE 0276 part 627, HD 627 S1and IEC Applications: Suitable for industry and distribution boards, power station, house connecting boxes and street lighting also as control cable for trasmission of control impulses and test datas Nominal voltage: Test voltage: Hightest voltage: Direct current system: Alternating current systems, single-phase system: 600/1000 V 4 kv 1800 V 1400 V Both conductor insulated. single-phase system: 700 V One conductor earthed three phase systems 1200 V With concentric conductor and a cross-section of 240 mm 2 and above: 3600 V Min. Bending Radius: Single core: 15 x d Multi cores: 12 x d Max tensile stress: 50 N/mm 2 Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC No, of cores Ca. mm No. of cores Ca. mm 46200G7L010M61 1 x 10 / G7L010M62 1 x 16 / G73020M15 2 x 1,5 / 1, G73020M25 2 x 2,5 / 2,5 13, G73020M40 2 x 4 / 4 15, G73020M60 2 x 6 / G73020M61 2 x 10 / 10 19, G73020M16 2 x 16 /16 20, G72031M15 3 G 1,5 /1,5 13, G72031M25 3 G 2,5 /2,5 14, G72031M40 3 G 4 / 4 16, G72031M60 3 G 6 / 6 17, G72031M61 3 G 10 / G72031M62 3 G 16 / G72041M15 4 G 1,5 /1,5 14, G72041M25 4 G 2,5 / 2,5 15, G72041M40 4 G 4 / G72041M60 4 G 6 / 6 18, G72041M61 4 G 10 / G72041M62 4 G 16 / G72051M15 5 G 1,5 / 1, G72051M25 5 G 2,5 / 2, G72051M40 5 G 4 / G72051M60 5 G 6 / G72051M61 5 G 10 / G70071M15 7 G 1,5 / 1,5 15, G70071M40 7 G 4 / G70071M60 7 G 6 / G70071M15 7 G 1,5 / 2, G70081M15 8 G 1,5 / 1, G70081M15 8 G 1,5 /2, G70101M15 10 G 1,5 / 2, G70121M15 12 G 1,5 / 2, G70141M15 14 G 1,5 / 2,5 20, G70161M15 16 G 1,5 / G70191M15 19 G 1,5 / G70211M15 21 G 1,5 / G70241M15 24 G 1,5 / G70301M15 30 G 1,5 / G70401M15 40 G 1,5 / G70521M15 52 G 1,5 / G70611M15 61 G 1,5 / G70071M25 7 G 2,5 / 2,5 17, G70081M25 8 G 2,5 / 2, G70101M25 10 G 2,5 / 4 20, G70121M25 12 G 2,5 / G70141M25 14 G 2,5 / G70141M25 14 G 2,5 / 6 22, G70161M25 16 G 2,5 / G70191M25 19 G 2,5 / 6 23, G70211M25 21 G 2,5 / G70241M25 24 G 2,5 / G70301M25 30 G 2,5 / G70401M25 40 G 2,5 / G70521M25 52 G 2,5 / G70611M25 61 G 2,5 / Other dimensions and colours available on request. 42

52 LOW VOLTAGE CABLES GAALFLEX VFD NYCWY Power cable with concentric copper conductor, connection to frequency converters, 0,6/1 kv Conductor: solid or stranded red copper conductor Cl. 1 or 2, acc. to IEC 60228, DIN VDE mm2 - round solid cores mm2 - stranded conductor Insulation: PVC,type DIV4 Colour core: acc. to DIN VDE 0293 part. 308 Stranding: cores stranded concentrically Inner sheath: filler compound Screen: concentric conductor of corrugated copper wires + copper tape Outer sheath: black (RAL 9005),PVC,type DMV5 Features: Acc. to DIN VDE 0276 part 603, HD 603 S1 and IEC Applications: Suitable especially for underground laying, for example in subscriber networks, power stations also as control cable for trasmission of control impulses and test datas Nominal voltage: 600/1000 V Test voltage: 4 kv Hightest voltage: Direct current system: 1800 V Alternating current systems, single-phase system: 1400 V Both conductor insulated. single-phase system: 700 V One conductor earthed three phase systems 1200 V With concentric conductor and a cross-section of 240 mm 2 and above: 3600 V Temperature range: Fixed installation: - 30 C up to + 70 C Flexible application: - 5 C up to + 50 C Min. Bending Radius: Single core: 15 x d Multi cores: 12 x d Max tensile stress: 50 N/mm 2 Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC No, of cores Ca. mm No, of cores Ca. mm 33250G73020M61 2 x 10 / G73020M62 2 x 16 / G73020M63 2 x 25 / G73030M61 3 x 10 / 10 19, G73030M62 3 x 16 / G73030M63 3 x 25 / G73030M64 3 x 35 / G73030M65 3 x 50 / G73030M66 3 x 70 / / G73030M67 3 x 95 / / G73030M68 3 x 120 / / G73030M69 3 x 150 / MCM 33250G73030M70 3 x 185 / MCM 33250G73030M71 3 x 240 / MCM 33251G73030M63 3 x 25 / G73030M64 3 x 35 / 35 27, G73030M65 3 x 50 / 50 29, G73030M66 3 x 70 / / G73030M67 3 x 95 / 95 38, / G73030M68 3 x 120 / / G73030M69 3 x 150 / MCM 33251G73030M70 3 x 185 / MCM 33250G73040M61 4 x 10 / 10 20, G73040M62 4 x 16 / 16 23, G73040M63 4 x 25 / G73040M64 4 x 35 / G73040M65 4 x 50 / G73040M66 4 x 70 / / G73040M67 4 x 95 / 50 43, / G73040M68 4x120 / 70 47, / G73040M69 4 x 150 / MCM 33250G73040M70 4 x 185 / MCM 33250G73040M71 4 x 240 / , MCM Other dimensions and colours available on request. 43

53 LOW VOLTAGE CABLES (N)AYCWY Power cable 0,6/1 kv with concentric aluminium conductor, connection to frequency converters Conductor: solid or stranded plain aluminium conductor Cl. 1 or 2, acc. to IEC 60228, DIN VDE mm2 - round solid cores mm2 - stranded conductor Insulation: PVC,type DIV4 Colour core: acc. to DIN VDE 0293 part. 308 Stranding: cores stranded concentriacally Screen: concentric conductor of corrugated copper wires + copper tape Outer sheath: black (RAL 9005),PVC,type DMV5 Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: fixed laying: -30 / +70 C flexible application: - 5 / +50 C Min. bending radius: 12 x d Max. permessible: 50 N/mm 2 Current carrying capacity: as for DIN VDE 0276 part. 603 Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN ,IEC Applications: Power cables for energy supply, preferibly used for underground laying, especially in subscriber networks, power station as well as control impulses and test datas. Overall, where increased electrical and also mechanical protection are required. Thosecables are installed in open air, in underground, in water, indoors and in cable ducts. Alu Alu 46210G73020M61 2x10 re/ G73020M62 2x16 re/ G73020M63 2x25 rm/ G73030M61 3x10 re/10 19, G73030M62 3x16 re/ G73030M63 3x25 rm/ G73030M64 3x35 sm/ G73030M65 3x50 sm/ G73030M66 3x70 sm/ / G73030M67 3x95 sm/ / G73030M68 3x120 sm/ / G73030M69 3x150 sm/ MCM 46210G73030M70 3x185 sm/ MCM 46210G73030M71 3x240 sm/ MCM 46210G73030M72 3x300 sm/ MCM 46210G73030M73 3x400 sm/ MCM 46211G73030M63 3x25 rm/ G73030M64 3x35 sm/35 27, G73030M65 3x50 sm/50 29, G73030M66 3x70 sm/ / G73030M67 3x95 sm/95 38, / G73030M68 3x120 sm/ / G73030M69 3x150 sm/ MCM 46211G73030M70 3x185 sm/ MCM 46210G73040M61 4x10 re/10 20, G73040M62 4x16 re/16 23, G73040M63 4x25 rm/ G73040M64 4x35 sm/ G73040M65 4x50 sm/ G73040M66 4x70 sm/ / G73040M67 4x95 sm/50 43, / G73040M68 4x120 sm/ / G73040M69 4x150 sm/ MCM 46210G73040M70 4x185 sm/ MCM 46210G73040M71 4x240 sm/120 62, MCM Other dimensions and colours available on request. 44

54 LOW VOLTAGE CABLES (N)2XY-J/O Power 0,6/1 kv acc. to VDE Conductor: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 Insulation: XLPE compound Colour core: 1 core: Y/G 3 cores: blue-brown-y/g 4 cores: Y/G, brown,black, grey 5 cores: Y/G-blue-brown-black-gray Outer sheath: black(ral 9005),PVC,type ST2 Features: sunlight resistant UV resistant Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: - 5 C / + 70 C Max. operating temp. on conductor: + 90 C Max. permitted operating voltage in 3 phase system: 1,2 kv Resistance: Flame retardant acc. to: PVC sel-extinguishing and flame retardant acc.to DIN VDE 0482 part /EN /IEC Halogen free acc. to: IEC EN DIN VDE 0482 part Oil resistant acc. to IEC , DIN VDE 0473 part (N)2XY-J 46220G72031M15 3G1.5 SW RE 12,5 43, G72031M25 3G2.5 SW RE 13,0 72, G72031M40 3G4 SW RE 15,0 115, G72031M60 3G6 SW RE 16,0 173, G72031M61 3G10 SW RE 18,0 288, G72031M62 3G16 SW RE 22,0 461, G72031M63 3G25 SW RM 25,0 720, G72031M64 3G35 SW SM 25,0 1008, G72031M65 3G50 SW SM 26,3 1440, G72031M66 3G70 SW SM 30,7 2016, / G72031M67 3G95 SW SM 34,3 2736, / G72035M63 3G25/16 SW SM 26,0 874, G72035M64 3G35/16 SW SM 26,3 1162, G72035M65 3G50/25 SW SM 30,3 1680, G72035M66 3G70/35 SW SM 33,3 2352, / G72035M67 3G95/50 SW SM 39,3 3216, / G72035M68 3G120/70 SW SM 42,7 4128, / G72035M69 3G150/70 SW SM 46,7 4992, MCM 46220G72035M70 3G185/95 SW SM 51,7 6240, MCM 46220G72035M71 3G240/120 SW SM 58,7 8064, MCM 46220G72035M72 3G300/150 SW SM 66, , MCM 46220G72041M15 4G1.5 SW RE 13,3 58, G72041M25 4G2.5 SW RE 14,3 96, G72041M40 4G4 SW RE 16,3 154, G72041M60 4G6 SW RE 16,3 230, G72041M61 4G10 SW RE 21,0 384, G72041M62 4G16 SW RE 22,3 614, G72041M63 4G25 SW RM 27,3 960, G72041M64 4G35 SW RM 29,3 1344, G72041M65 4G50 SW SM 31,3 1920, G72041M66 4G70 SW SM 35,3 2688, / G72041M67 4G95 SW SM 40,3 3648, / G72041M68 4G120 SW SM 43,7 4608, / G72041M69 4G150 SW SM 48,7 5760, MCM 46220G72041M70 4G185 SW SM 53,7 7104, MCM 46220G72051M15 5G1.5 SW RE 14,0 72, G72051M25 5G2.5 SW RE 15,0 120, G72051M40 5G4 SW RE 17,0 192, G72051M60 5G6 SW RE 19,0 288, G72051M61 5G10 SW RE 21,0 480, G72051M62 5G16 SW RE 23,0 768, G72051M63 5G25 SW RM 29,0 1200, G72051M65 5G50 SW RM 43,0 2400, G72051M69 5G150 SW RM 49,0 7200, MCM 46220G70071M15 7G1.5 SW RE 15,0 101, G70071M25 7G2.5 SW RE 17,0 168, G70071M40 7G4 SW RE 18,0 269, G70121M15 12G1.5 SW RE 20,0 173, G70121M25 12G2.5 SW RE 23,0 288, G70241M15 24G1.5 SW RE 23,5 346, G70241M25 24G2.5 SW RE 31,0 576,

55 LOW VOLTAGE CABLES (N)2XY-J/O Power 0,6/1 kv acc. to VDE (N)2XY-O Part no, No,of cores ca,mm approx, no,*) Part no, No,of cores ca,mm approx, no,*) 46220G7L010M62 1x16 SW RE 11,7 154, G7L010M63 1x25 SW RM 13,0 240, G7L010M64 1x35 SW RM 14,0 336, G7L010M65 1x50 SW RM 15,5 480, G7L010M66 1x70 SW RM 17,0 672, / G7L010M67 1x95 SW RM 19,0 912, / G7L010M68 1x120 SW RM 21,0 1152, / G7L010M69 1x150 SW RM 23,3 1440, MCM 46220G7L010M70 1x185 SW RM 25,3 1776, MCM 46220G7L010M71 1x240 SW RM 28,3 2304, MCM 46220G7L010M72 1x300 SW RM 30,3 2880, MCM 46220G7L010M73 1x400 SW RM 34,7 3840, MCM 46220G7L010M74 1x500 SW RM 38,0 4800, MCM 46220G73020M15 2x1,5 SW RE 11,5 29, G73020M40 2x4 SW RE 13,5 77, G73020M60 2x6 SW RE 15,5 115, G73020M61 2x10 SW RE 17,0 192, G73020M62 2x16 SW RE 17,5 307, G73020M63 2x25 SW RM 22,0 480, G73020M64 2x35 SW RM - 672, G73020M65 2x50 SW RM - 960, G73020M66 2x70 SW RM 30,7 1344, /0 Other dimensions and colours available on request. 46

56 LOW VOLTAGE CABLES U-1000 R2V Conductor: Insulation: Colour core: Wrapping: Outer sheath: solid or stranded red copper conductor Cl. 1 or 2, acc. to IEC XLPE compound 2 cores: blue-brown 3 cores: brown-black-blue(1,2/2,5 mm 2 ) 3G cores: brown,black, grey (4 mm 2 ) 4 cores: blue-brown-black-gray 4G cores: brown-black-gray-y/g 5 cores: brown-blue-grey-black 5 G cores: blue-brown-black-gray-y/g non fibrous and not hygroscopic filler black(ral 9005),PVC compound Nominal voltage: 600/1000 V Test voltage: 3,5 V Temperature range: -10 C / +90 C Max. short circuit temp. on conductor: C Min. bending radius: 6 x d Max. pulling stress: 5 kg/mm 2 Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC Oil resistant acc. to: IEC , DIN VDE 0473 part Features: Acc. to NFC C32-321/A1 acc. to IEC Applications: For use in industrial sites and the upright columns of buildings. particulary suited in cases of high resistance to solar radiation and athmospheric agents is required good resistance to low temperatures and chemical agents. Can be used without additional mechanical protection in the open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general. can be laid underground with mechanical protection constucted from slab, tiles, or bricks. It is no racomended to lay this cable in ground flooded for more than two months for year. With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15% It can be used in ambient temperatures down to G7L010M15 1x1.5 6,6 14, G7L010M25 1x2.5 7,0 24, G7L010M40 1x4 7,6 38, G7L010M60 1x6 8,2 37, G7L010M61 1x10 9,2 96, G7L010M62 1x16 10,5 153, G7L010M63 1x25 12,5 240, G7L010M64 1x35 13,5 336, G7L010M65 1x50 15,0 480, G7L010M66 1x70 17,0 672, / G7L010M67 1x95 19,0 912, / G7L010M68 1x120 21,0 1152, / G7L010M69 1x150 23,0 1440, MCM 46230G7L010M70 1x185 25,5 1776, MCM 46230G7L010M71 1x240 28,5 2304, MCM 46230G7L010M72 1x300 31,0 2880, MCM 46230G73020M15 2x1.5 10,5 28, G73020M25 2x2.5 11,5 48,

57 LOW VOLTAGE CABLES U-1000 R2V 46230G73020M40 2x4 13,0 76, G73020M60 2x6 14,0 115, G73020M61 2x10 16,0 192, G73020M62 2x16 18,5 307, G73020M63 2x25 22,0 480, G73020M64 2x35 24,5 672, G73030M15 3x1,5 11,0 43, G73030M25 3x2,5 12,5 72, G73030M40 3x4 13,5 115, G73030M60 3x6 15,0 172, G73030M61 3x10 17,0 288, G73030M62 3x16 19,5 460, G73030M63 3x25 23,5 720, G73030M64 3x35 26,0 1008, G73030M65 3x50 29,0 1440, G73030M66 3x70 34,0 2016, / G73030M67 3x95 38,5 2736, / G73030M68 3x120 42,5 3456, / G73030M69 3x150 47,5 4320, MCM 46230G73030M70 3x185 53,0 5328, MCM 46230G73030M71 3x240 59,5 6912, MCM 46230G73030M72 3x300 66,0 8640, MCM 46230G72041M15 4G1,5 12,0 59, G72041M25 4G2,5 13,0 96, G72041M40 4G4 14,5 153, G72041M60 4G6 16,0 230, G72041M61 4G10 18,5 384, G72041M62 4G16 21,0 614, G72041M63 4G25 25,5 960, G72041M64 4G35 28,5 1344, G73035M65 3x50+1x35 31,1 1776, G73035M66 3x70+1x50 36,2 2496, / G73035M67 3x95+1x50 40,6 3216, / G73035M68 3x120+1x70 45,4 4128, / G73035M69 3x150+1x70 49,5 4992, MCM 46230G73035M70 3x185+1x70 54,4 6000, MCM 46230G73035M71 3x240+1x95 61,5 7824, MCM 46230G73050M15 5x1,5 13,0 72, G73050M25 5x2,5 14,5 120, G73050M40 5x4 16,0 192, G73050M60 5x6 17,5 288, G73050M61 5x10 20,0 480, G73050M62 5x16 23,0 768, G73050M63 5x25 28,0 1200, G70071M15 7x1,5 13,5 100, G70071M25 7x2,5 15,0 168, G70101M15 10x2,5 19,0 240, G70101M25 10x1,5 16,5 144, G70121M15 12x1,5 17,0 172, G70121M25 12x2,5 19,5 240, G70141M15 14x1,5 18,0 201, G70141M25 14x2,5 20,5 336, G70191M15 19x1,5 19,5 273, G70191M25 19x2,5 22,5 456, G70241M15 24x1,5 22,5 345, G70241M25 24x2,5 25,5 576, Other dimensions and colours available on request. 48

58 LOW VOLTAGE CABLES U-1000 RV FV Conductor: Insulation: Cores colour: Wrapping: Armouring: Outer sheath: solid or stranded red copper conductor Cl. 1 or 2, acc. to IEC XLPE compound 2 cores: blue-brown 3 cores: brown-black-blue(1,2/2,5 mm 2 ) 3G cores: brown,black, grey (4 mm 2 ) 4 cores: blue-brown-black-gray 4G cores: brown-black-gray-y/g 5 cores: brown-blue-grey-black 5 G cores: blue-brown-black-gray-y/g non fibrous and not hygroscopic filler two steel tape black(ral 9005),PVC compound Features: Acc. to NFC C32-321/A1 acc. to IEC Applications: For use in industrial sites and the upright columns of buildings. particulary suited in cases of high resistance to solar radiation and athmospheric agents is required good resistance to low temperatures and chemical agents. Can be used without additional mechanical protection in the open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general. can be laid underground with mechanical protection constucted from slab, tiles, or bricks. It is no racomended to lay this cable in ground flooded for more than two months for year. With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15% It can be used in ambient temperatures down to Nominal voltage: 300/500 V Test voltage: 1,2 V Min. bending radius: 6 x d Temperature range: - 10 C / + 90 C Max. short circuit temp. on conductor: C Nominal voltage: 0,6/1 kv Max. pulling stress: 5 kg/mm 2 Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC No flame propagation acc. to: I EN EN acc. to part 2 EN and G7L010M15 1x1,5 6,6 14, G7L010M25 1x2,5 7,0 24, G7L010M40 1x4 7,6 38, G7L010M60 1x6 8,2 37, G7L010M61 1x10 9,2 96, G7L010M62 1x16 10,5 153, G7L010M63 1x25 12,5 240, G7L010M64 1x35 13,5 336, G7L010M65 1x50 15,0 480, G7L010M66 1x70 17,0 672, / G7L010M67 1x95 19,0 912, / G7L010M68 1x120 21,0 1152, / G7L010M69 1x150 23,0 1440, MCM 46240G7L010M70 1x185 25,5 1776, MCM 46240G7L010M71 1x240 28,5 2304, MCM 46240G7L010M72 1x300 31,0 2880,0-550 MCM 46240G73020M15 2x1,5 10,5 28,

59 LOW VOLTAGE CABLES U-1000 RV FV 46240G73020M25 2x2,5 11,5 48, G73020M40 2x4 13,0 76, G73020M60 2x6 14,0 115, G73020M61 2x10 16,0 192, G73020M62 2x16 18,5 307, G73020M63 2x25 22,0 480, G73020M64 2x35 24,5 672, G73030M15 3x1,5 11,0 43, G73030M25 3x2,5 12,5 72, G72031M40 3G4 13,5 115, G72031M60 3x6 15,0 172, G72031M61 3G10 17,0 288, G72031M62 3G16 19,5 460, G72031M63 3G25 23,5 720, G72031M64 3G35 26,0 1008, G72031M65 3G50 29,0 1440, G72031M66 3G70 34,0 2016, / G72031M67 3G95 38,5 2736, / G72031M68 3G120 42,5 3456, / G72031M69 3G150 47,5 4320, MCM 46240G72031M70 3G185 53,0 5328, MCM 46240G72031M71 3G240 59,5 6912, MCM 46240G72031M72 3G300 66,0 8640, MCM 46240G72041M15 4G1,5 12,0 59, G72041M25 4G2,5 13,0 96, G72041M40 4G4 14,5 153, G72041M60 4G6 16,0 230, G72041M61 4G10 18,5 384, G72041M62 4G16 21,0 614, G72041M63 4G25 25,5 960, G72041M64 4G35 28,5 1344, G72035M64 3x35+1x25 28, G72035M65 3x50+1x35 31,1 1776, G72035M66 3x70+1x50 36,2 2496, / G72035M67 3x95+1x50 40,6 3216, / G72035M68 3x120+1x70 45,4 4128, / G72035M69 3x150+1x70 49,5 4992, MCM 46240G72035M70 3x185+1x70 54,4 6000, MCM 46240G72035M71 3x240+1x95 61,5 7824, MCM 46240G72051M15 5G1,5 13,0 72, G72051M25 5G2,5 14,5 120, G72051M40 5G4 16,0 192, G72051M60 5G6 17,5 288, G72051M61 5G10 20,0 480, G72051M62 5G16 23,0 768, G72051M63 5G25 28,0 1200, G70071M15 7x1,5 13,5 100, G70071M25 7x2,5 15,0 168, G70101M15 10x1,5 16,5 144, G70121M15 12x1,5 17,0 172, G70101M25 10x2,5 19,0 240, G70121M25 12x2,5 19,5 240, G70141M15 14x1,5 18,0 201, G70141M25 14x2,5 20,5 336, G70191M15 19x1,5 19,5 273, G70191M25 19x2,5 22,5 456, G70241M15 24x1,5 22,5 345, G70241M25 24x2,5 25,5 576, Other dimensions and colours available on request. 50

60 LOW VOLTAGE CABLES RV-K Conductor: Insulation: Cores colour: Outer sheath: ffexible red copper conductor Cl. 5, acc to IEC XLPE compound 1 cores: black 2 cores: blue-brown, 3 cores: brown-black-gray 4 cores: blue-brown-black-gray black(ral 9005),PVC compound Application: This cable for energy distribution is suitable for all types of low voltage industrial-type connections. Its high flexibility makes the installation process substantially easier and as a result is particularly suitable for use in difficult layouts. It can be buried or installed in a tube as well as outdoors without requiring additional protection. Lastly, RV-K cable can withstand damp conditions. Features: acc.to HD603-1 Nominal voltage: 600/1000 kv Test voltage: 4 kv Temperature range: Fixed installation: -50 C / +80 C Flexible installation: -35 C / +80 C Temperaure at conductor: in service: + 90 C in short circuit: C Min. bending radius: 5 x d 46250G7L010M40 1x4 re 9, G7L010M60 1x6 re 9, G7L010M61 1x10 re 10, G7L010M62 1x16 re 11, G7L010M63 1x25 rm 12, G7L010M64 1x35 rm 13, G7L010M65 1x50 rm 15, G7L010M66 1x70 rm 16, / G7L010M67 1x95 rm 19, / G7L010M68 1x120 rm 20, / G7L010M69 1x150 rm 22, MCM 46250G7L010M70 1x185 rm 25, MCM 46250G7L010M71 1x240 rm 28, MCM 46250G7L010M72 1x300 rm 30, MCM 46250G7L010M73 1x400 rm 34, MCM 46250G7L010M74 1x500 rm 38, MCM 46250G7L010M75 1x630 rm 43, MCM 46250G73020M15 2x1,5 re 11, G73020M25 2x2,5 re 12, G73020M40 2x4 re 14, G73020M60 2x6 re 5, G73020M61 2x10 re 16, G73020M62 2x16 re 18, G73020M63 2x25 rm 23, G73030M15 3x1.5 re 11, G73030M25 3x2.5 re 12, G73030M40 3x4 re 14, G73030M60 3x6 re 15, G73030M61 3x10 re 17, G73030M62 3x16 re 19, G73030M63 3x25 rm 24, G73030M64 3x35 sm 25, G73030M65 3x50 sm 26, G73030M66 3x70 sm 30, / G73030M67 3x95 sm 34, / G73030M68 3x120 sm 37, / G73030M69 3x150 sm 40, MCM 46250G73030M70 3x185 sm 46, MCM 46250G73030M71 3x240 sm 51, MCM 46250G73040M15 4x1.5 re 9,7 57, G73040M25 4x2.5 rm 10,7 96, G73040M40 4x4 re 12,0 153, G73040M60 4x6 re 13,4 230, G73040M61 4x10 re 15, G73040M62 4x16 re 18,2 614, G73040M63 4x25 rm 24, G73040M64 4x35 sm 26, G73040M65 4x50 sm 31, G73040M66 4x70 sm 36, / G73040M67 4x95 sm 40, /0 Other dimensions and colours available on request. 51

61 LOW VOLTAGE CABLES RE4(O)R (XLPE/PVC) Conductor: Insulation: Cores colour: Outer sheath : stranded red copper conductor Cl. 2, acc to IEC XLPE compound 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light-blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores: Y/G-black-light blue-brown-black black(ral 9005),PVC compound Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: Min. Bending Radius: 600/1000 V 4 kv - 25 o C / + 90 o C 0 o C / + 90 o C + 90 o C o C 12 x d Features: Construction according to IEC Max tensile stress: Resistance: 5 kg x mm 2 Flame retardant acc. to: PVC sel-extinguishing and flame retardant acc.to DIN VDE 0482 part /EN /IEC On request: DIN VDE 0482 part , EN IEC C POWER Part no, No,of cores ca,mm approx, no,*) 46260G7L010M15 1x1,5 5,5 4, G7L010M25 1x2, G7L010M40 1x4 6,5 38, G7L010M60 1x6 7 57, G7L010M61 1x G7L010M62 1x G7L010M63 1x G7L010M64 1x G7L010M65 1x50 13, G7L010M66 1x70 15, / G7L010M67 1x95 17, / G7L010M68 1x120 19, / G7L010M69 1x150 21, MCM 46260G7L010M70 1x MCM 46260G7L010M71 1x240 26, MCM 46260G7L010M72 1x MCM 46260G7L010M73 1x MCM 46260G7L010M74 1x MCM 46260G7L010M75 1x630 43, MCM 52

62 LOW VOLTAGE CABLES RE4(O)R (XLPE/PVC) Part no, No,of cores ca,mm approx, no,*) 46260G73020M15 2x1,5 8,5 28, G73020M25 2x2,5 9, G73020M40 2x4 10,5 76, G73020M60 2x6 11,5 115, G73020M61 2x10 13, G73020M62 2x16 15,5 307, G73020M63 2x G73020M64 2x G73020M65 2x G73020M66 2x / G73020M67 2x / G73020M68 2x / G73020M69 2x MCM 46260G73020M70 2x MCM 46260G72031M15 3G1,5 9 43, G72031M25 3G2, G72031M40 3G , G72031M60 3G , G72031M61 3G G72031M62 3G16 16, G72031M63 3G G72031M64 3G35 22, G72031M65 3G G72031M66 3G / G72031M67 3G / G72031M68 3G / G72031M69 3G MCM 46260G72031M70 3G MCM 46260G72041M15 4G1, , G72041M25 4G2, G72041M40 4G , G72041M60 4G6 13,5 230, G72041M61 4G G72041M62 4G16 18,5 614, G72041M63 4G25 22, G72041M64 4G G72041M65 4G G72041M66 4G / G72041M67 4G / G72041M68 4G / G72041M69 4G MCM 46260G72041M70 4G MCM 46260G72035M64 3x35+1x G72035M65 3x50+1x G72035M66 3x70+1x G72035M67 3x95+1x G72035M68 3x120+1x G72035M69 3x150+1x / G72035M70 3x185+1x / G72035M71 3x240+1x / G72035M72 3x300+1x /0 CONTROL 46260G73050M15 5x1,5 12, G71070M15 7x1,5 13,1 100, G71100M15 10x1,5 13, G71120M15 12x1,5 15,2 172, G71160M15 16x1,5-230, G71190M15 19x1,5 17,3 273, G71240M15 24x1,5 20,2 345, G71070M25 7x2,5 13, G71100M25 10x2,5 15, G71120M25 12x2,5 17, , G71160M25 16x2, G71190M25 19x2,5 21, G71240M25 24x2,5 24, Other dimensions and colours available on request. 53

63 LOW VOLTAGE CABLES FE4(O)CR inverter, connection to frequency converters Conductor: flexible red copper conductor Cl.5, acc.to IEC Insulation: XLPE compound Cores colour: brown - grey - black Stranding: cores laying to concentric crowns to ensure roundness to the cable. Inner sheath: PVC,type R2 Screen: red copper braid of the same section as the phase conductor (for sections up to 16 mm 2 ) or equal to half phase conductor, with a minimum of 16 mm2 (for section greater than 25 mm 2 ) Outer sheath: grey (RAL 7001),PVC,type Rz Features: according to IEC and I 20-13, I-UNEL Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: Fixed installation: -50 C / + 80 C Flexible installation: -35 C /+ 80 C Temperaure at conductor: in service: + 90 C in short circuit: C Min. bending radius: 8 x d Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC Current capacity at 30 C 33200G83030M25 3x2,5+SH 14, G83030M40 3x4+SH 15, G83030M60 3x6 +SH 18, G83030M61 3x10+SH 21, G83030M62 3x16+SH 25, G83030M63 3x25+SH 28, G83030M64 3x35+SH 32, G83030M65 3x50+SH 36, G83030M66 3x70+SH 40, / G83030M67 3x95+SH 47, / G83030M68 3x120+SH 52, / G83030M69 3x150+SH 56, MCM 33200G83030M70 3x185+SH 64, MCM 33200G83030M71 3x240+SH 74, MCM 33200G83030M72 3x300+SH 85, MCM Temperature C: K Factor: ,17 1,12 1,06 0,94 0,87 0,79 0,71 0,61 0,50 Other dimension and colours available on request. 54

64 LOW VOLTAGE CABLES RE4(O)FR (XLPE/PVC/SWA/PVC) Construction acc. to IEC Conductor: Insulation: Colour core: Inner sheath: Armour: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC XLPE compound 2 cores: brown-blue 3 cores: brown-black-gray (or brown-blue-y/g) 4 cores: brown-black-gray-blue (or brown-blue-grey-y/g) 5 cores: numbered cores (or brown-blue-grey-blue-y/g) 6 cores and above: numbered cores (or numbered cores +Y/G) PVC compound Steel wires black(ral 9005),PVC compound Features: according to IEC on request 300/500 V Nominal voltage: Test voltage: Temperature range: Temperature at conductor: in service: in short circuit: Min. Bending Radius: Max tensile stress: Resistance: 600/1000 V 4 kv - 0 o C / + 90 o C + 90 o C o C 1,5 up to 16 mm 2 : 8 x d 25 mm 2 and above: 8 x d 5 kg x mm 2 Flame retardant and self extinguishing: acc. to IEC , DIN VDE 0482 part , EN acc. to IEC , EN , DIN VDE 0482 part POWER 46270G73020M15 2 x 1,5 12,3 28, G73020M25 2 x 2,5 13, G73020M40 2 x 4 14,7 76, G73020M60 2 x 6 15,9 115, G73020M61 2 x G73020M62 2 x , G73020M63 2 x 25 24, G73020M64 2 x 35 27, G73020M65 2 x 50 25, G73020M66 2 x / G73020M67 2 x 95 33, / G73020M68 2 x , / G73020M69 2 x , MCM 46270G73020M70 2 x , MCM 46270G73020M71 2 x MCM 46270G73020M72 2 x , MCM 46270G73020M73 2 x MCM 46270G72031M15 3 G 1,5 12,8 43, G72031M25 3 G 2,5 14, G72031M40 3 G 4 15,3 115, G72031M60 3 G 6 16,6 172, G72031M61 3 G 10 19, G72031M62 3 G 16 21,2 460, G72031M63 3 G 25 26, G72031M64 3 G 35 29, G72031M65 3 G 50 28, G72031M66 3 G 70 32, / G72031M67 3 G / G72031M68 3 G , / G72031M69 3G , MCM 46270G72031M70 3 G , MCM 46270G72031M71 3 G , MCM 46270G72031M72 3 G , MCM 46270G72031M73 3 G , MCM 46270G72041M15 4 G 1,5 13,5 57, G72041M25 4 G 2, G72041M40 4 G 4 16,4 153, G72041M60 4 G 6 18,7 230, G72041M61 4 G 10 21, G72041M62 4 G 16 22,9 614, G72041M63 4 G 25 28, G72041M64 4 G 35 32, G72041M65 4 G G72041M66 4 G 70 37, / G72041M67 4 G 95 41, / G72041M68 4 G , / G72041M69 4 G , MCM 46270G72041M70 4 G , MCM 46270G72041M71 4 G MCM 46270G72041M72 4 G , MCM 46270G72041M73 4 G , MCM 55

65 LOW VOLTAGE CABLES RE4(O)FR (XLPE/PVC/SWA/PVC) Construction acc. to IEC CONTROL 46270G73050M15 5 x 1,5 14, G73050M25 5 x 2, G73050M40 5 x 4 18, G73050M60 5 x 6 19, G73050M61 5 x 10 23, G73050M62 5 x 16 26, G73050M63 5 x 25 31, G73050M64 5 x G73050M65 5 x G73050M66 5 x / G73050M67 5 x / G71060M15 6 x 1,5 15,2 86, G71060M25 6 x 2,5 17, G71060M40 6 x 4 19,7 230, G71060M60 6 x 6 21,3 345, G71060M61 6 x 10 25, G71060M62 6 x 16 28,8 921, G71060M63 6 x 25 34, G71070M15 7 x 1,5 15,2 100, G71070M25 7 x 2,5 17, G71070M40 7 x 4 19,7 268, G71070M60 7 x 6 21,3 403, G71070M61 7 x 10 25, G71070M62 7 x 16 28,8 1075, G71070M63 7 x 25 38, G71080M15 8 x 1,5 17,6 115, G71080M25 8 x 2,5 18, G71080M40 8 x 4 21,2 396, G71080M60 8 x 6 24,1 460, G71080M61 8 x 10 27, G71100M15 10 x 1,5 19, G71100M25 10 x 2,5 21, G71100M40 10 x 4 25, G71100M60 10 x 6 27, G71100M61 10 x 10 31, G71120M15 12 x 1,5 19,4 172, G71120M25 12 x 2,5 22, G71120M40 12 x 4 27,7 460, G71120M60 12 x , G71120M61 12 x 10 32, G71160M15 16 x 1,5 21,9 230, G71160M25 16 x 2, G71160M40 16 x 4 29,1 614, G71160M60 16 x 6 30,4 921, G71190M15 19 x 1,5 23,2 273, G71190M25 19 x 2,5 26, G71190M40 19 x 4 29,3 729, G71220M15 22 x 1,5 27,3 316, G71220M25 22 x 2,5 29, G71220M40 22 x 4 33,5 844, G71270M15 27 x 1,5 27,9 388, G71270M25 27 x 2,5 30, G71270M40 27 x 4 34,2 1036, G71300M15 30 x 1,5 28, G71300M25 30 x 2,5 31, G71370M15 37 x 1,5 30,6 532, G71370M25 37 x 2,5 33, G71370M40 37 x 4 39,6 1420, G71400M15 40 x 1,5 31, G71400M25 40 x 2,5 35, G71480M15 48 x 1,5 33,9 691, G71480M25 48 x 2,5 38, G71480M40 48 x 4 44,6 1843,2-12 Other dimensions and colours available on request. 56

66 LOW VOLTAGE CABLES RE4(O)FR (XLPE/PVC/SWA/PVC) BS 5467 Conductor: Insulation: Colour core: Inner sheath: Armour: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC XLPE compound 2 cores: brown-blue 3 cores: brown-black-gray (or brown-blue-y/g) 4 cores: brown-black-gray-blue (or brown-blue-grey-y/g) 5 cores: numbered cores (or brown-blue-grey-blue-y/g) 6 cores and above: numbered cores (or numbered cores +Y/G) PVC compound steel wires black(ral 9005),PVC compound Features: acc. to IEC BS 5467 on request 300/500 V Nominal voltage: Test voltage: Temperature range: Temperature at conductor: in service: in short circuit: Min. Bending Radius: Max tensile stress: Resistance: 600/1000 V 4 kv - 0 o C / + 90 o C + 90 o C o C 1,5 up to 16 mm 2 : 8 x d 25 mm 2 and above: 8 x d 5 kg x mm 2 Flame retardant and self extinguishing: acc. to IEC , DIN VDE 0482 part , EN acc. to IEC , EN , DIN VDE 0482 part POWER 46280G73020M15 2 x 1,5 12,3 28, G73020M25 2 x 2,5 13, G73020M40 2 x 4 14,7 76, G73020M60 2 x 6 15,9 115, G73020M61 2 x G73020M62 2 x , G73020M63 2 x 25 24, G73020M64 2 x 35 27, G73020M65 2 x 50 25, G73020M66 2 x / G73020M67 2 x 95 33, / G73020M68 2 x , / G73020M69 2 x , MCM 46280G73020M70 2 x , MCM 46280G73020M71 2 x MCM 46280G73020M72 2 x , MCM 46280G73020M73 2 x MCM 46280G72031M15 3 G 1,5 12,8 43, G72031M25 3 G 2,5 14, G72031M40 3 G 4 15,3 115, G72031M60 3 G 6 16,6 172, G72031M61 3 G 10 19, G72031M62 3 G 16 21,2 460, G72031M63 3 G 25 26, G72031M64 3 G 35 29, G72031M65 3 G 50 28, G72031M66 3 G 70 32, / G72031M67 3 G / G72031M68 3 G , / G72031M69 3G , MCM 46280G72031M70 3 G , MCM 46280G72031M71 3 G , MCM 46280G72031M72 3 G , MCM 46280G72031M73 3 G , MCM 46280G72041M15 4 G 1,5 13,5 57, G72041M25 4 G 2, G72041M40 4 G 4 16,4 153, G72041M60 4 G 6 18,7 230, G72041M61 4 G 10 21, G72041M62 4 G 16 22,9 614, G72041M63 4 G 25 28, G72041M64 4 G 35 32, G72041M65 4 G G72041M66 4 G 70 37, / G72041M67 4 G 95 41, / G72041M68 4 G , / G72041M69 4 G , MCM 46280G72041M70 4 G , MCM 46280G72041M71 4 G MCM 46280G72041M72 4 G , MCM 46280G72041M73 4 G , MCM 57

67 LOW VOLTAGE CABLES RE4(O)FR (XLPE/PVC/SWA/PVC) 0,6/1 kv according to BS 5467 CONTROL 46280G73050M15 5 x 1,5 14, G73050M25 5 x 2, G73050M40 5 x 4 18, G73050M60 5 x 6 19, G73050M61 5 x 10 23, G73050M62 5 x 16 26, G73050M63 5 x 25 31, G73050M64 5 x G73050M65 5 x G73050M66 5 x / G73050M67 5 x / G71060M15 6 x 1,5 15,2 86, G71060M25 6 x 2,5 17, G71060M40 6 x 4 19,7 230, G71060M60 6 x 6 21,3 345, G71060M61 6 x 10 25, G71060M62 6 x 16 28,8 921, G71060M63 6 x 25 34, G71070M15 7 x 1,5 15,2 100, G71070M25 7 x 2,5 17, G71070M40 7 x 4 19,7 268, G71070M60 7 x 6 21,3 403, G71070M61 7 x 10 25, G71070M62 7 x 16 28,8 1075, G71070M63 7 x 25 38, G71080M15 8 x 1,5 17,6 115, G71080M25 8 x 2,5 18, G71080M40 8 x 4 21,2 396, G71080M60 8 x 6 24,1 460, G71080M61 8 x 10 27, G71100M15 10 x 1,5 19, G71100M25 10 x 2,5 21, G71100M40 10 x 4 25, G71100M60 10 x 6 27, G71100M61 10 x 10 31, G71120M15 12 x 1,5 19,4 172, G71120M25 12 x 2,5 22, G71120M40 12 x 4 27,7 460, G71120M60 12 x , G71120M61 12 x 10 32, G71160M15 16 x 1,5 21,9 230, G71160M25 16 x 2, G71160M40 16 x 4 29,1 614, G71160M60 16 x 6 30,4 921, G71190M15 19 x 1,5 23,2 273, G71190M25 19 x 2,5 26, G71190M40 19 x 4 29,3 729, G71220M15 22 x 1,5 27,3 316, G71220M25 22 x 2,5 29, G71220M40 22 x 4 33,5 844, G71270M15 27 x 1,5 27,9 388, G71270M25 27 x 2,5 30, G71270M40 27 x 4 34,2 1036, G71300M15 30 x 1,5 28, G71300M25 30 x 2,5 31, G71370M15 37 x 1,5 30,6 532, G71370M25 37 x 2,5 33, G71370M40 37 x 4 39,6 1420, G71400M15 40 x 1,5 31, G71400M25 40 x 2,5 35, G71480M15 48 x 1,5 33,9 691, G71480M25 48 x 2,5 38, G71480M40 48 x 4 44,6 1843,2-12 Other dimensions and colours available on request. 58

68 LOW VOLTAGE CABLES RE4(O)M1 (XLPE/LS0H)(RE4(O)H) Conductor: Insulation: Cores colour : stranded red copper conductor Cl. 2, acc to IEC XLPE compound 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light-blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores:y/g-black-light blue-brown-black Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: 600/1000 V 4 kv - 25 o C / + 90 o C - 5 o C / + 90 o C + 90 o C o C Outer sheath: black (RAL 9005), halogen-free compound Min. Bending Radius: 12 x d Max tensile stress: 5 kg x mm 2 Features: according to IEC Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Halogen free acc. to: EN , IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part POWER 46290G7L010M15 1x1,5 9,6 4, G7L010M25 1x2,5 10, G7L010M40 1x4 11,5 38, G7L010M60 1x6 12,6 57, G7L010M61 1x10 15, G7L010M62 1x16 17,0 153, G7L010M63 1x25 20, G7L010M64 1x35 22, G7L010M65 1x50 24, G7L010M66 1x70 28, / G7L010M67 1x95 32, / G7L010M68 1x120 36, / G7L010M69 1x150 40, MCM 46290G7L010M70 1x185 44, MCM 46290G7L010M71 1x240 10, MCM 46290G7L010M72 1x300 10, MCM 46290G7L010M73 1x400 12, MCM 46290G7L010M74 1x500 13, MCM 46290G7L010M75 1x630 15, MCM 46290G73020M15 2x1,5 17,9 28, G73020M25 2x2,5 21, G73020M40 2x4 23,7 76, G73020M60 2x6 26,4 115,

69 LOW VOLTAGE CABLES RE4(O)M1 (XLPE/LS0H)(RE4(O)H) 46290G73020M61 2x10 30, G73020M62 2x16 34,3 307, G73020M63 2x25 39, G73020M64 2x35 43, G73020M65 2x50 47, G73020M66 2x70 10, / G73020M67 2x95 11, / G73020M68 2x120 13, / G73020M69 2x150 14, MCM 46290G73020M70 2x185 17, MCM 46290G72031M15 3G1,5 19,5 43, G72031M25 3G2,5 23, G72031M40 3G4 26,0 115, G72031M60 3G6 29,2 172, G72031M61 3G10 34, G72031M62 3G16 38,7 460, G72031M63 3G25 43, G72031M64 3G35 47, G72031M65 3G50 53, G72031M66 3G70 25, / G72031M67 3G95 27, / G72031M68 3G120 32, / G72031M69 3G150 36, MCM 46290G72031M70 3G185 41, MCM 46290G72041M15 4G1,5 46,1 57, G72041M25 4G2,5 49, G72041M40 4G4 58,2 153, G72041M60 4G6 62,9 230, G72041M61 4G10 5, G72041M62 4G16 6,2 614, G72041M63 4G25 6, G72041M64 4G35 7, G72041M65 4G50 8, G72041M66 4G70 9, / G72041M67 4G95 10, / G72041M68 4G120 11, / G72041M69 4G150 13, MCM 46290G72041M70 4G185 14, MCM 46290G72035M64 3x35+1x25 16, G72035M65 3x50+1x25 18, G72035M66 3x70+1x35 20, G72035M67 3x95+1x70 22, G72035M68 3x120+1x70 25, G72035M69 3x150+1x95 27, / G72035M70 3x185+1x95 31, / G72035M71 3x240+1x150 34, / G72035M72 3x300+1x150 39, /0 Other dimensions and colours available on request. CONTROL 46290G73050M15 5x1,5 12, G71070M15 7x1,5 13,1 100, G71100M15 10x1,5 13, G71120M15 12x1,5 15,2 172, G71160M15 16x1,5-230, G71190M15 19x1,5 17,3 273, G71240M15 24x1,5 20,2 345, G71070M25 7x2,5 13, G71100M25 10x2,5 15, G71120M25 12x2,5 17, G71160M25 16x2, G71190M25 19x2,5 21, G71240M25 24x2,5 24, Other dimensions and colours available on request. 60

70 LOW VOLTAGE CABLES RE4(O)FM1 (XLPE/LS0H/SWA/LS0H) Conductor: Insulation: Cores colour: Inner sheath: Armour: stranded red copper conductor Cl. 2, acc to IEC XLPE compound 1 core: black 2 cores: light blue-black 3 cores: light blue-brown-black, (or Y/G-black-light-blue) 4 cores: light blue-brown-black-black, (or Y/G-black-light blue-brown) 5 cores:y/g-black-light blue-brown-black Thermoplastic,halogen free compound steel wires Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: Min. Bending Radius: 600/1000 V 4 kv - 25 o C / + 90 o C 0 o C / + 90 o C + 90 o C o C 14 x d Outer sheath: black (RAL 9005), halogen-free compound Max tensile stress: 5 kg x mm 2 Features: according to IEC Resistance: Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: IEC , EN , DIN VDE 0482 part G7L010M15 1x1,5-14, G7L010M25 1x2, G7L010M40 1x4-38, G7L010M60 1x6-57, G7L010M61 1x G7L010M62 1x16-153, G7L010M63 1x G7L010M64 1x G7L010M65 1x50 19, G7L010M66 1x70 21, / G7L010M67 1x95 23, / G7L010M68 1x120 25, / G7L010M69 1x150 26, MCM 46300G7L010M70 1x185 28, MCM 46300G7L010M71 1x240 31, MCM 46300G7L010M72 1x300 34, MCM 46300G7L010M73 1x400 37, MCM 46300G7L010M74 1x500 41, MCM 46300G7L010M75 1x630 45, MCM 61

71 LOW VOLTAGE CABLES RE4(O)FM1 (XLPE/LS0H/SWA/LS0H) POWER 46300G73020M15 2x1,5 13,3 28, G73020M25 2x2,5 14, G73020M40 2x4 15,1 76, G73020M60 2x6 16,2 115, G73020M61 2x10 18, G73020M62 2x16 20,4 307, G73020M63 2x25 24, G73020M64 2x35 26, G73020M65 2x50 28, G73020M66 2x70 33, / G73020M67 2x95 37, / G73020M68 2x120 41, / G73020M69 2x150 45, MCM 46300G73020M70 2x185 50, MCM 46300G72031M15 3G1,5 13,7 43, G72031M25 3G2,5 14, G72031M40 3G4 15,7 115, G72031M60 3G6 16,9 172, G72031M61 3G10 19, G72031M62 3G16 21,3 460, G72031M63 3G25 25, G72031M64 3G35 27, G72031M65 3G50 30, G72031M66 3G70 36, / G72031M67 3G95 40, / G72031M68 3G120 44, / G72031M69 3G150 49, MCM 46300G72031M70 3G185 54, MCM 46300G72041M15 4G1.5 14,5 57, G72041M25 4G2.5 15, G72041M40 4G4 16,8 153, G72041M60 4G6 19,0 230, G72041M61 4G10 20, G72041M62 4G16 23,6 614, G72041M63 4G25 27, G72041M64 4G35 30, G72041M65 4G50 33, G72041M66 4G70 39, / G72041M67 4G95 43, / G72041M68 4G120 49, / G72041M69 4G150 54, MCM 46300G72041M70 4G185 59, MCM 46300G72035M64 3x35+1x25 29, G72035M65 3x50+1x25 32, G72035M66 3x70+1x35 37, G72035M67 3x95+1x70 41, G72035M68 3x120+1x70 46, G72035M69 3x150+1x95 52, / G72035M70 3x185+1x95 56, / G72035M71 3x240+1x150 64, / G72035M72 3x300+1x150 69, /0 CONTROL 46300G73050M15 5x1,5 12, G71070M15 7x1,5 13,1 100, G71100M15 10x1,5 13, G71120M15 12x1,5 15,2 172, G71160M15 16x1,5-230, G71190M15 19x1,5 17,3 273, G71240M15 24x1,5 20,2 345, G71070M25 7x2,5 13, G71100M25 10x2,5 15, G71120M25 12x2,5 17, G71160M25 16x2, G71190M25 19x2,5 21, G71240M25 24x2,5 24, Other dimensions and colours available on request. 62

72 LOW VOLTAGE CABLES N2XH Conductor: Insulation: Colour code: Stranding: Wrapping: Outer sheath: plain Cu wire conductor,single or multiple-wire, according to DIN VDE 0295 cl.1 and IEC cl. 1 or 2, HD 383 Halogen-free core insulation,cross-linked polyethylene compound 2XI1,to HD 604 S1 colour coding of cores according to DIN VDE and HD 186 cores stranded in layers. filling compound or wrapped tape. black,thermoplastic polyolefine compound HM4 to HD 604 S1 Features: Power cable 0,6/1 kv Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range fixed laying: flexible application: Resistance: 600/1000 V 4 kv 15 x d 12 x d up to 100x10 6 cj/kg - 30 o C to + 90 o C - 5 o C to + 50 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part rm=round conductor multiple wire, re= round conductor single wire Outer-Ø ± 10% Outer-Ø ± 10% 46310G7L010M40 1x4 re G7L010M60 1x6 re G7L010M61 1x10 re G7L010M62 1x16 rm G7L010M63 1x25 rm G7L010M64 1x35 rm G7L010M65 1x50 rm G7L010M66 1x70 rm / G7L010M67 1x95 rm / G7L010M68 1x120 rm / G7L010M69 1x150 rm MCM 46310G7L010M70 1x185 rm MCM 46310G7L010M71 1x240 rm MCM 46310G7L010M72 1x300 rm MCM 46310G73020M15 2x1,5 re G73020M25 2x2,5 re 12, G73020M40 2x4 re 13, G73020M60 2x6 re 14, G73020M61 2x10 re 16, G73020M62 2x16 re 17, G73020M63 2x25 rm G72031M15 3G1,5 re G72031M25 3G2,5 re G72031M40 3G4 re G72031M60 3G6 re G72031M61 3G10 re G72031M62 3G16 re G72031M63 3G25 rm 21, G72031M64 3G35 rm 24, G72031M65 3G50 rm 25, G72031M66 3G70 rm 29, / G72031M67 3G95 rm / G72031M68 3G120 rm 34, / G72031M69 3G150 rm 39, MCM 46310G72031M70 3G185 rm 44, MCM 46310G72031M71 3G240 rm 49, MCM 46310G72041M15 4G1,5 re G72041M25 4G2,5 re G72041M40 4G4 re G72041M60 4G6 re G72041M61 4G10 re G72041M62 4G16 re G72041M63 4G25 rm G72041M64 4G35 rm G72041M65 4G50 rm G72041M66 4G70 rm / G72041M67 4G95 rm / G72041M68 4G120 rm 40, / G72041M69 4G150 rm 45, MCM 46310G72041M70 4G185 rm 49, MCM 46310G72041M71 4G240 rm MCM 46310G72051M15 5G1,5 re 14, G72051M25 5G2,5 re G72051M40 5G4 re G72051M60 5G6 re 18, G72051M61 5G10 re G72051M62 5G16 re G70071M15 7G1,5 re 15, G70071M25 7G2,5 re G70071M40 7G4 re 17, G70101M15 10G1,5 re 18, G70101M25 10G2,5 re G70121M15 12G1,5 re G70121M25 12G2,5 re G70121M40 12G4 re 21, G70141M15 14G1,5 re G70141M25 14G2,5 re G70191M15 19G1,5 re G70191M25 19G2,5 re G70241M15 24G1,5 re G70241M25 24G2,5 re G70301M15 30G1,5 re G70301M25 30G2,5 re

73 LOW VOLTAGE CABLES N2XH 3+1/2 conductors Outer-Ø ± 10% 46310G72035M65 3X50/25 rm 28, G72035M66 3X70/35 rm 31, / G72035M67 3X59/50 rm 34, / G72035M68 3X120/70 rm / G72035M69 3X150/70 43, MCM 46310G72035M70 3X185/95 47, MCM 46310G72035M71 3X240/120 53, MCM Other dimensions and colours available on request. 64

74 LOW VOLTAGE CABLES N2XCH Conductor: Insulation: Colour code: Stranding: Wrapping: Screen: Outer sheath: plain Cu wire conductor,single or multiple-wire, according to DIN VDE 0295 cl.1 and IEC cl. 1 or 2, HD 383 Halogen-free core insulation,cross-linked polyethylene compound 2XI1,to HD 604 S1 colour coding of cores according to DIN VDE and HD 186 cores stranded in layers. filling compound or wrapped tape. concentric conductor of plain Cu wires. black,thermoplastic polyolefine compound HM4 to HD 604 S1 Features: Power cable 0,6/1 kv Nominal voltage: Test voltage: Min.bending radius: fixed laying: flexible application: Radiation resistance: Temperature range fixed laying: flexible application: Resistance: 600/1000 V 4 kv 15 x d 12 x d up to 100x10 6 cj/kg - 30 o C to + 90 o C - 5 o C to + 50 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 46320G73020M15 2x1,5/1,5 re G73020M25 2x2,5/2,5 re 15 81, G73020M40 2x4/4 re G73020M60 2x6/6 re G73020M61 2x10/10 re G73020M62 2x16/16 re 19, G73030M15 3x1,5/1,5 re 14, G73030M25 3x2,5/2,5 re 15, G73030M40 3x4/4 re 16, G73030M60 3x6/6 re G73030M61 3x10/10 re G73030M62 3x16/16 re 22, G73030M63 3x25/16 re G73030M64 3x35/16 re 27, G73030M65 3x50/25 re 32, G73030M66 3x70/35 re 35, / G73030M67 3x95/50 re / G73030M68 3x120/70 re / G73030M69 3x150/70 re 43, MCM 46320G73030M70 3x185/95 re 47, MCM 46320G73030M71 3x240/120 re 53, MCM 46320G73040M15 4x1,5/1,5 re 15, G73040M25 4x2,5/2,5 re 16, G73040M40 4x4/4 re 17, Other dimensions and colours available on request. 65

75 LOW VOLTAGE CABLES N2XCH Outer-Ø ± 10% 46320G73040M60 4X6/6 re G73040M61 4X10/10 re 21, G73040M62 4X16/16 re 24, G73040M63 4X25/16 rm G73040M64 4X35/16 rm 29, G73040M65 4X50/25 rm 32, G73040M66 4X70/35 rm / G73040M67 4X95/50 rm 43, / G73040M68 4X120/70 rm 50, / G73040M69 4X150/70 rm 52, MCM 46320G73040M70 4X185/95 rm 57, MCM 46320G73040M71 4X240/120 re 62, MCM 46320G70070M15 7X1,5/2,5 re 14, G70070M25 7X2,5/2,5 re 15, G70070M40 7X4/4 re 18, G70100M15 10X1,5/2,5 re 17, G70100M25 10X2,5/4 re 18, G70120M15 12X1,5/2,5 re 18, G70120M25 12X2,5/4 re 19, G70120M40 12X4/6 re 22, G70160M15 16X1,5/4 re G70160M25 16X2,5/6 re 20, G70210M15 21X1,5/6 re 22, G70210M25 21X2,5/6 re 25, G70240M15 24X1,5/6 re 23, G70240M25 24X2,5/10 re 26, G70300M15 30X1,5/6 re 24, G70300M25 30X2,5/10 re Other dimensions and colours available on request. 66

76 LOW VOLTAGE CABLES GAALFLEX CONTROL 07BQ-F PUR power cable. single core, 450/750 V Conductor: flexible red copper conductor Cl. 5, acc to IEC 60228, DIN VDE 0295 Insulation: rubber compound Core colour: acc. to DIN VDE NELEC HD 308 S2* Stranding: in layer Outer sheath: orange (RAL 2003),PUR Features: Chemical resistant Uv resistant Abrasion resistant Applications: Connecting cable used in hand-held electric tools, for flexible and fixed installation. Suitable in dry, humid or wet rooms. Outdoor use within temperature range, no laying underground Nominal voltage: 450/750 V Test voltage: 2,5 kv Temperature range: Fixed laying: -40 up to +90 C Flexible installation: -40 up to +90 C Min. bending radius: 10 x d Insulation resistance: min. 20 MΩ x km Current carrying capacity: acc. to DIN VDE 07BQ-F single core 31310EGL010M62 1x16 10,8 153, EGL010M63 1x25 12,8 240, EGL010M64 1x35 15,3 336, EGL010M65 1x50 16,8 480, EGL010M66 1x70 19,0 672, / EGL010M67 1x95 21,8 912, / EGL010M68 1x120 24,3 1152, / EGL010M69 1x150 26,6 1440, MCM 31310EGL010M70 1x185 29,2 1776, MCM 31310EGL010M71 1x240 33,0 2304, MCM 31310EGL010M72 1x300 35,0 2880, MCM Other dimensions and colours available on request. Other dimensions and colours available on request. * Black or green/yellow insulation L: black PE: green/yellow. 67

77 LOW VOLTAGE CABLES GAALFLEX CONTROL (H)07BQ-F PUR power cable, multi core, 450/750 V Conductor: Insulation: Core colours: Stranding: Outer sheath: flexible red copper conductor Cl. 5, acc to IEC 60228, DIN VDE 0295 rubber compound up to 5 cores coloured. Y/G from 3 cores acc. to DIN VDE NELEC HD 308* in layer orange (RAL 2003),PUR Nominal voltage: Test voltage: Temperature range: Fixed laying: Flexible installation: Min. bending radius: Insulation resistance: 450/750 V 2,5 kv -40 up to +90 C -40 up to +90 C 4 x d min. 20 MΩ x km Features: Current carrying capacity: acc. to DIN VDE Chemical resistant Uv resistant Abrasion resistant acc. to standard HD S1 and DIN VDE 0282 T10 acc. to HAR HD S1 (H07BQ-F) Applications: Connecting cable used in hand-held electric tools. for flexible and fixed installation. Suitable in dry. humid or wet rooms. Outdoor use within temperature range. no laying underground No. of cores Ca. mm 31310EG3020M15 2 x 1, , EG2031M15 3 G 1,5 9,3 43, EG2041M15 4 G 1,5 10,5 57, EG2051M15 5 G 1,5 11, EG2031M25 3 G 2,5 11, EG2041M25 4 G 2,5 12, EG2051M25 5 G 2,5 13, EG2041M40 4 G 4 14,7 153, EG2051M40 5 G 4 16, EG2041M60 4 G 6 16,4 230, EG2051M60 5 G 6 18, EG2041M61 4 G 10 21, EG2051M61 5 G 10 23, EG2041M62 4 G16 24,4 614, EG2051M62 5 G16 27, EG2041M63 4G25 29, EG2051M63 5G EG2041M64 4G35 33, EG2051M64 5G EG2041M65 4G50 39, EG2051M65 5G EG2041M66 4G / EG2051M66 5G / EG2051M67 5G /0 Other dimensions and colours available on request. 68

78 MEDIUM VOLTAGE CABLES RG7H1R Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape red(ral 3000),PVC,type RZ Features: according to IEC Nominal voltage: Test voltage: Temperature during installation: Temperature at conductor: in service: in short circuit: Min. bending radius: Max. tensile stress: Resistance: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 0 o C to + 90 o C + 90 C C 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv 12 x d 6 kg x mm 2 Flame retardant and sel-extinguishing: acc.to DIN VDE 0482 part /EN / IEC ,8/3 kv 6/10 kv 48010KRL010M61 1x10 14, KRL010M62 1x16 15,2 153, KRL010M63 1x25 16, KRL010M64 1x35 17, KRL010M65 1x50 18, KRL010M66 1x / KRL010M67 1x / KRL010M68 1x120 23, / KRL010M69 1x150 24, MCM 48010KRL010M70 1x185 26, MCM 48010KRL010M71 1x MCM 48010KRL010M72 1x300 31, MCM 48010KRL010M73 1x400 34, MCM 48010KRL010M74 1x500 38, MCM 48010KRL010M75 1x630 43, MCM 48010QRL010M61 1x10 19, QRL010M62 1x16 20,4 153, QRL010M63 1x25 21, QRL010M64 1x35 23, QRL010M65 1x50 24, QRL010M66 1x70 26, / QRL010M67 1x95 27, / QRL010M68 1x120 29, / QRL010M69 1x150 30, MCM 48010QRL010M70 1x185 32, MCM 48010QRL010M71 1x240 35, MCM 48010QRL010M72 1x300 37, MCM 48010QRL010M73 1x400 40, MCM 48010QRL010M74 1x500 44, MCM 48010QRL010M75 1x630 54, MCM 3,6/6 kv 8,7/15 kv 48010MRL010M61 1x MRL010M62 1x16 17,5 153, MRL010M63 1x25 18, MRL010M64 1x35 19, MRL010M65 1x50 21, MRL010M66 1x70 23, / MRL010M67 1x95 24, / MRL010M68 1x120 26, / MRL010M69 1x150 27, MCM 48010MRL010M70 1x185 29, MCM 48010MRL010M71 1x240 32, MCM 48010MRL010M72 1x300 34, MCM 48010MRL010M73 1x400 37, MCM 48010MRL010M74 1x500 41, MCM 48010MRL010M75 1x630 45, MCM 48010SRL010M61 1x , SRL010M62 1x25 24, SRL010M63 1x35 25, SRL010M64 1x50 26, SRL010M65 1x70 28, / SRL010M66 1x95 30, / SRL010M67 1x120 31, / SRL010M68 1x150 33, MCM 48010SRL010M69 1x185 35, MCM 48010SRL010M70 1x240 38, MCM 48010SRL010M71 1x300 40, MCM 48010SRL010M72 1x400 43, MCM 48010SRL010M73 1x500 47, MCM 48010SRL010M74 1x630 52, MCM 69

79 MEDIUM VOLTAGE CABLES RG7H1R 12/20 kv 26/45 kv 48010URL010M64 1x35 27, URL010M65 1x50 28, URL010M66 1x70 30, / URL010M67 1x95 32, / URL010M68 1x120 33, / URL010M69 1x150 35, MCM 48010URL010M70 1x MCM 48010URL010M71 1x240 39, MCM 48010URL010M72 1x MCM 48010URL010M73 1x400 45, MCM 48010URL010M74 1x MCM 48010URL010M75 1x630 53, MCM 48010ZRL010M66 1x / ZRL010M67 1x / ZRL010M68 1x120 45, / ZRL010M69 1x MCM 48010ZRL010M70 1x MCM 48010ZRL010M71 1x240 49, MCM 48010ZRL010M72 1x MCM 48010ZRL010M73 1x MCM 48010ZRL010M74 1x MCM 48010ZRL010M75 1x MCM Other dimensions and colours available on request. 18/30 kv 48010XRL010M65 1x50 35, XRL010M66 1x70 36, / XRL010M67 1x95 37, / XRL010M68 1x120 39, / XRL010M69 1x150 40, MCM 48010XRL010M70 1x185 42, MCM 48010XRL010M71 1x240 45, MCM 48010XRL010M72 1x300 47, MCM 48010XRL010M73 1x400 51, MCM 48010XRL010M74 1x MCM 48010XRL010M75 1x630 61, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 70

80 MEDIUM VOLTAGE CABLES RG7H1(O)R Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape red(ral 3000),PVC,type RZ Nominal voltage: Test voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv 26/45 kv = 63 kv Features: Temperature range: in service: in short circuit: + 90 C C according to IEC Min. bending radius: 12 x d Resistance: Flame retardant and sel-extinguishing: acc.to DIN VDE 0482 part / EN /IEC ,8/3 kv 6/10 kv 48010KR1030M61 3x10 27, KR1030M62 3x16 29,5 460, KR1030M63 3x25 32, KR1030M64 3x35 34, KR1030M65 3x50 37, KR1030M66 3x70 41, / KR1030M67 3x / KR1030M68 3x120 48, / KR1030M69 3x150 52, MCM 48010KR1030M70 3x185 56, MCM 48010KR1030M71 3x MCM 48010KR1030M72 3x300 67, MCM 48010KR1030M73 3x400 74, MCM 48010QR1030M61 3x10 36, QR1030M62 3x , QR1030M63 3x QR1030M64 3x QR1030M65 3x QR1030M66 3x / QR1030M67 3x / QR1030M68 3x120 57, / QR1030M69 3x MCM 48010QR1030M70 3x MCM 48010QR1030M71 3x240 72, MCM 48010QR1030M72 3x300 77, MCM 48010QR1030M73 3x MCM 3,6/6 kv 8,7/15 kv 48010MR1030M61 3x10 31, MR1030M62 3x16 34,4 460, MR1030M63 3x25 37, MR1030M64 3x35 39, MR1030M65 3x50 42, MR1030M66 3x70 46, / MR1030M67 3x / MR1030M68 3x120 54, / MR1030M69 3x150 57, MCM 48010MR1030M70 3x185 61, MCM 48010MR1030M71 3x240 66, MCM 48010MR1030M72 3x300 72, MCM 48010MR1030M73 3x400 78, MCM 48010SR1030M62 3x16 45,5 460, SR1030M63 3x SR1030M64 3x35 51, SR1030M65 3x50 53, SR1030M66 3x / SR1030M67 3x95 61, / SR1030M68 3x / SR1030M69 3x150 68, MCM 48010SR1030M70 3x185 72, MCM 48010SR1030M71 3x240 78, MCM 48010SR1030M72 3x300 78, MCM 71

81 MEDIUM VOLTAGE CABLES RG7H1(O)R 12/20 kv 18/30 kv * For cables laying in earth a screen-cross section of 16 mm is permitted UR1030M64 3x35 57, UR1030M65 3x50 60, UR1030M66 3x70 64, / UR1030M67 3x95 69, / UR1030M68 3x120 74, / UR1030M69 3x MCM 48010UR1030M70 3x185 80, MCM 48010UR1030M71 3x MCM 48010UR1030M72 3x300 91, MCM 48010XR1030M65 3x XR1030M66 3x70 75, / XR1030M67 3x95 80, / XR1030M68 3x120 83, / XR1030M69 3x150 86, MCM 48010XR1030M70 3x MCM 48010XR1030M71 3x240 96, MCM Other dimensions and colours available on request. 72

82 MEDIUM VOLTAGE CABLES RG7H1NR Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper wires and one or two copper tape(s) applied helically. aluminium tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Nominal voltage: Test voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: according to IEC Temperature range: in service: in short circuit: Resistance: + 90 C C Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv 48020KRL010M61 1x KRL010M62 1x KRL010M63 1x KRL010M64 1x KRL010M65 1x KRL010M66 1x / KRL010M67 1x / KRL010M68 1x / KRL010M69 1x MCM 48020KRL010M70 1x MCM 48020KRL010M71 1x MCM 48020KRL010M72 1x MCM 48020KRL010M73 1x MCM 3,6/6 kv 8,7/15 kv 48020QRL010M61 1x QRL010M62 1x QRL010M63 1x QRL010M64 1x QRL010M65 1x QRL010M66 1x / QRL010M67 1x / QRL010M68 1x / QRL010M69 1x MCM 48020QRL010M70 1x MCM 48020QRL010M71 1x MCM 48020QRL010M72 1x MCM 48020QRL010M73 1x MCM 48020MRL010M61 1x MRL010M62 1x MRL010M63 1x MRL010M64 1x MRL010M65 1x MRL010M66 1x / MRL010M67 1x / MRL010M68 1x / MRL010M69 1x MCM 48020MRL010M70 1x MCM 48020MRL010M71 1x MCM 48020MRL010M72 1x MCM 48020MRL010M73 1x MCM 48020SRL010M62 1x SRL010M63 1x SRL010M64 1x SRL010M65 1x SRL010M66 1x / SRL010M67 1x / SRL010M68 1x / SRL010M69 1x MCM 48020SRL010M70 1x MCM 48020SRL010M71 1x MCM 48020SRL010M72 1x MCM 73

83 MEDIUM VOLTAGE CABLES RG7H1NR 12/20 kv 18/30 kv 48020URL010M64 1x URL010M65 1x URL010M66 1x / URL010M67 1x / URL010M68 1x / URL010M69 1x MCM 48020URL010M70 1x MCM 48020URL010M71 1x MCM 48020URL010M72 1x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XRL010M65 1x XRL010M66 1x / XRL010M67 1x / XRL010M68 1x / XRL010M69 1x MCM 48020XRL010M70 1x MCM 48020XRL010M71 1x MCM Other dimensions and colours available on request. 74

84 MEDIUM VOLTAGE CABLES RG7H1(O)NR Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape steel tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Min. bending radius: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = V 6/10 kv = V + 90 C C 12 x d 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv according to IEC Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv 48020KR1030M61 3x10 29, KR1030M62 3x16 31, KR1030M63 3x25 34, KR1030M64 3x35 36, KR1030M65 3x50 39, KR1030M66 3x70 43, / KR1030M67 3x95 47, / KR1030M68 3x120 51, / KR1030M69 3x150 54, MCM 48020KR1030M70 3x185 58, MCM 48020KR1030M71 3x240 64, MCM 48020KR1030M72 3x300 77, MCM 48020KR1030M73 3x400 78, MCM 3,6/6 kv 8,7/15 kv 48020QR1030M61 3x10 41, QR1030M62 3x16 44, QR1030M63 3x25 47, QR1030M64 3x35 50, QR1030M65 3x50 53, QR1030M66 3x70 57, / QR1030M67 3x95 60, / QR1030M68 3x120 65, / QR1030M69 3x150 68, MCM 48020QR1030M70 3x185 72, MCM 48020QR1030M71 3x240 78, MCM 48020QR1030M72 3x300 84, MCM 48020QR1030M73 3x400 90, MCM 48020MR1030M61 3x10 33, MR1030M62 3x16 36, MR1030M63 3x25 39, MR1030M64 3x35 41, MR1030M65 3x50 44, MR1030M66 3x70 48, / MR1030M67 3x95 52, / MR1030M68 3x120 56, / MR1030M69 3x150 59, MCM 48020MR1030M70 3x185 64, MCM 48020MR1030M71 3x240 69, MCM 48020MR1030M72 3x300 76, MCM 48020MR1030M73 3x400 83, MCM 48020SR1030M62 3x16 49, SR1030M63 3x25 52, SR1030M64 3x35 55, SR1030M65 3x50 57, SR1030M66 3x70 61, / SR1030M67 3x95 65, / SR1030M68 3x120 69, / SR1030M69 3x150 72, MCM 48020SR1030M70 3x185 76, MCM 48020SR1030M71 3x240 82, MCM 48020SR1030M72 3x300 88, MCM 75

85 MEDIUM VOLTAGE CABLES RG7H1(O)NR 12/20 kv 18/30 kv 48020UR1030M64 3x UR1030M65 3x UR1030M66 3x / UR1030M67 3x / UR1030M68 3x / UR1030M69 3x MCM 48020UR1030M70 3x MCM 48020UR1030M71 3x MCM 48020UR1030M72 3x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XR1030M65 3x XR1030M66 3x / XR1030M67 3x / XR1030M68 3x / XR1030M69 3x MCM 48020XR1030M70 3x MCM 48020XR1030M71 3x MCM Other dimensions and colours available on request. 76

86 MEDIUM VOLTAGE CABLES RG7H1ZR Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber, type G7 red copper wires and one or two copper tape(s) applied helically steel tape red(ral 3000),PVC,type RZ Nominal voltage: Test voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = V 6/10 kv = V Features: Temperature range: in service: in short circuit: + 90 C C according to IEC Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv 48030KRL010M61 1x KRL010M62 1x KRL010M63 1x KRL010M64 1x KRL010M65 1x KRL010M66 1x / KRL010M67 1x / KRL010M68 1x / KRL010M69 1x MCM 48030KRL010M70 1x MCM 48030KRL010M71 1x MCM 48030KRL010M72 1x MCM 48030KRL010M73 1x MCM 48030QRL010M61 1x QRL010M62 1x QRL010M63 1x QRL010M64 1x QRL010M65 1x QRL010M66 1x / QRL010M67 1x / QRL010M68 1x / QRL010M69 1x MCM 48030QRL010M70 1x MCM 48030QRL010M71 1x MCM 48030QRL010M72 1x MCM 48030QRL010M73 1x MCM 3,6/6 kv 8,7/15 kv 48030MRL010M61 1x MRL010M62 1x MRL010M63 1x MRL010M64 1x MRL010M65 1x MRL010M66 1x / MRL010M67 1x / MRL010M68 1x / MRL010M69 1x MCM 48030MRL010M70 1x MCM 48030MRL010M71 1x MCM 48030MRL010M72 1x MCM 48030MRL010M73 1x MCM 48030SRL010M62 1x SRL010M63 1x SRL010M64 1x SRL010M65 1x SRL010M66 1x / SRL010M67 1x / SRL010M68 1x / SRL010M69 1x MCM 48030SRL010M70 1x MCM 48030SRL010M71 1x MCM 48030SRL010M72 1x MCM 77

87 MEDIUM VOLTAGE CABLES RG7H1ZR 12/20 kv 18/30 kv * For cables laying in earth a screen-cross section of 16 mm is permitted URL010M64 1x URL010M65 1x URL010M66 1x / URL010M67 1x / URL010M68 1x / URL010M69 1x MCM 48030URL010M70 1x MCM 48030URL010M71 1x MCM 48030URL010M72 1x MCM Other dimensions and colours available on request XRL010M65 1x XRL010M66 1x / XRL010M67 1x / XRL010M68 1x / XRL010M69 1x MCM 48030XRL010M70 1x MCM 48030XRL010M71 1x MCM 78

88 MEDIUM VOLTAGE CABLES RG7H1(O)ZR Conductor: Insulation: Screen: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape Nominal voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv Armouring: Outer sheat: steel tape red(ral 3000),PVC,type RZ Test voltage: 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: according to IEC Temperature range: in service: in short circuit: Resistance: + 90 C C Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 8,7/15 kv 48030KR1030M61 3x KR1030M62 3x KR1030M63 3x KR1030M64 3x KR1030M65 3x KR1030M66 3x / KR1030M67 3x / KR1030M68 3x / KR1030M69 3x MCM 48030KR1030M70 3x MCM 48030KR1030M71 3x MCM 48030KR1030M72 3x MCM 48030KR1030M73 3x MCM 3,6/6 kv 48030QR1030M61 3x QR1030M62 3x QR1030M63 3x QR1030M64 3x QR1030M65 3x / QR1030M66 3x / QR1030M67 3x / QR1030M68 3x MCM 48030QR1030M69 3x MCM 48030QR1030M70 3x MCM 48030QR1030M71 3x MCM 12/20 kv 48030MR1030M61 3x MR1030M62 3x MR1030M63 3x MR1030M64 3x MR1030M65 3x MR1030M66 3x / MR1030M67 3x / MR1030M68 3x / MR1030M69 3x MCM 48030MR1030M70 3x MCM 48030MR1030M71 3x MCM 48030MR1030M72 3x MCM 48030MR1030M73 3x MCM 48030SR1030M63 3x SR1030M64 3x SR1030M65 3x / SR1030M66 3x / SR1030M67 3x / SR1030M68 3x MCM 48030SR1030M69 3x MCM 48030SR1030M70 3x MCM 48030SR1030M71 3x MCM 79

89 MEDIUM VOLTAGE CABLES RG7H1(O)ZR 6/10 kv 18/30 kv 48030UR1030M61 3x UR1030M62 3x UR1030M63 3x UR1030M64 3x UR1030M65 3x UR1030M66 3x / UR1030M67 3x / UR1030M68 3x / UR1030M69 3x MCM 48030UR1030M70 3x MCM 48030UR1030M71 3x MCM 48030UR1030M72 3x MCM 48030UR1030M73 3x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XR1030M65 3x XR1030M66 3x / XR1030M67 3x / XR1030M68 3x / XR1030M69 3x MCM 48030XR1030M70 3x MCM 48030XR1030M71 3x MCM Other dimensions and colours available on request. 80

90 MEDIUM VOLTAGE CABLES ARG7H1E Single-core, overall copper wires + tape screen 12/20 kv up to 18/30 kv Conductor: Inner semi-conductive layer: Insulation: Outer semi-conductive layer: Screen: Outer sheath: stranded plain aluminium conductor Cl.2, acc. to IEC extruded compound special EPR type DIH2 strippable cold extruded compound red copper wires and one or two copper tape(s) applied helically. red(ral 3000),PE type DMZ1 Nominal voltage: Test voltage: Temperature range: 12/20 kv up to 18/30 kv 12/20 kv = 29 kv 18/30 kv = 43 kv -25 C up to +105 C Max. short circuit temp: C Min. bending radius: 13 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC Features: According to IEC /20 kv 18/30 kv No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps Alu 48040URL010M63 1 x 35 26, URL010M64 1 x 50 26, URL010M65 1 x 70 28, / URL010M66 1 x 95 29, / URL010M67 1 x , / URL010M68 1 x , MCM 48040URL010M69 1 x MCM 48040URL010M70 1 x , MCM 48040URL010M71 1 x , MCM 48040URL010M72 1 x , MCM 48040URL010M73 1 x , MCM 48040URL010M75 1 x , MCM No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps Alu 48040XRL010M64 1 x 50 34, XRL010M65 1 x 70 34, / XRL010M66 1 x 95 35, / XRL010M67 1x , / XRL010M68 1 x , MCM 48040XRL010M69 1 x , MCM 48040XRL010M70 1 x , MCM 48040XRL010M71 1 x , MCM 48040XRL010M72 1 x , MCM 48040XRL010M73 1 x , MCM 48040XRL010M75 1 x , MCM Other dimension and colors available on request. 81

91 MEDIUM VOLTAGE CABLES ARG7H1EX Three-cores, overall copper wires + tape screen 12/20 kv up to 18/30 kv Conductor: Inner semi-conductive layer: Insulation: Outer semi-conductive layer: Screen: Outer sheath: stranded plain aluminium conductor Cl.2, acc. to IEC extruded compound special EPR type DIH2 strippable cold extruded compound red copper wires and one or two copper tape(s) applied helically. red(ral 3000),PE type DMZ1 Nominal voltage: Test voltage: Temperature range: 12/20 kv up to 18/30 kv 12/20 kv = 29 kv 18/30 kv = 43 kv -25 C up to +105 C Max. short circuit temp: C Min. bending radius: 13 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC Features: According to IEC /20 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground P=1 C m/w - P=2 C m/w Amps Alu 48050URL030M63 3 x 1 x 35 26, URL030M64 3 x 1 x 50 26, URL030M65 3 x 1 x 70 28, / URL030M66 3 x 1x 95 29, / URL030M67 3 x 1x , / URL030M68 3 x 1 x , MCM 48050URL030M69 3 x 1 x MCM 48050URL030M70 3 x 1 x , MCM 48050URL030M71 3 x 1 x , MCM 48050URL030M72 3 x 1 x , MCM 18/30 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground P=1 C m/w - P=2 C m/w Amps Alu 48050XRL030M64 3 x 1 x 50 34, XRL030M65 3 x 1 x 70 34, / XRL030M66 3 x 1 x 95 35, / XRL030M67 3 x 1x , / XRL030M68 3 x 1 x , MCM 48050XRL030M69 3 x 1 x , MCM 48050XRL030M70 3 x 1 x , MCM 48050XRL030M71 3 x 1 x , MCM 48050XRL030M72 3 x 1 x , MCM Other dimension and colors available on request. 82

92 MEDIUM VOLTAGE CABLES RG7H1M1 Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Min. bending radius: Resistance: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: Acc. to normatives DIN VDE and IEC standards C C 12 x d Flame retardant: acc.to IEC DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 6/10 kv 48060KRL010M61 1x10 14, KRL010M62 1x16 15,0 153, KRL010M63 1x25 16, KRL010M64 1x35 17, KRL010M65 1x50 18, KRL010M66 1x70 20, / KRL010M67 1x95 22, / KRL010M68 1x120 24, / KRL010M69 1x150 26, MCM 48060KRL010M70 1x185 27, MCM 48060KRL010M71 1x240 30, MCM 48060KRL010M72 1x300 32, MCM 48060KRL010M73 1x400 35, MCM 48060KRL010M74 1x500 40, MCM 48060KRL010M75 1x630 44, MCM 48060QRL010M61 1x10 19, QRL010M62 1x16 21,0 153, QRL010M63 1x25 22, QRL010M64 1x35 23, QRL010M65 1x50 24, QRL010M66 1x70 26, / QRL010M67 1x95 28, / QRL010M68 1x120 29, / QRL010M69 1x150 31, MCM 48060QRL010M70 1x185 33, MCM 48060QRL010M71 1x240 35, MCM 48060QRL010M72 1x300 38, MCM 48060QRL010M73 1x400 41, MCM 48060QRL010M74 1x500 45, MCM 48060QRL0107M5 1x630 48, MCM 3,6/6 kv 8,7/15 kv 48060MRL010M61 1x10 16, MRL010M62 1x16 17,0 153, MRL010M63 1x25 18, MRL010M64 1x35 20, MRL010M65 1x50 21, MRL010M66 1x70 23, / MRL010M67 1x95 25, / MRL010M68 1x120 26, / MRL010M69 1x150 28, MCM 48060MRL010M70 1x185 30, MCM 48060MRL010M71 1x240 32, MCM 48060MRL010M72 1x300 35, MCM 48060MRL010M73 1x400 37, MCM 48060MRL010M74 1x500 41, MCM 48060MRL010M75 1x630 46, MCM 48060SRL010M62 1x16 23,3 153, SRL010M63 1x25 24, SRL010M64 1x35 25, SRL010M65 1x50 27, SRL010M66 1x70 28, / SRL010M67 1x95 30, / SRL010M68 1x120 32, / SRL010M69 1x150 33, MCM 48060SRL010M70 1x185 35, MCM 48060SRL010M71 1x240 38, MCM 48060SRL010M72 1x300 41, MCM 48060SRL010M73 1x400 43, MCM 48060SRL010M74 1x500 47, MCM 48060SRL010M75 1x630 52, MCM 83

93 MEDIUM VOLTAGE CABLES RG7H1M1 12/20 kv 26/45 kv part no, No,of cores ca,mm approx, no,*) 48060URL010M64 1x35 27, URL010M65 1x50 29, URL010M66 1x70 30, / URL010M67 1x95 33, / URL010M68 1x120 34, / URL010M69 1x150 36, MCM 48060URL010M70 1x185 37, MCM 48060URL010M71 1x240 40, MCM 48060URL010M72 1x300 43, MCM 48060URL010M73 1x400 45, MCM 48060URL010M74 1x500 50, MCM 48060URL010M75 1x630 54, MCM 48060ZRL010M66 1x70 41, / ZRL010M67 1x95 43, / ZRL010M68 1x120 44, / ZRL010M69 1x150 45, MCM 48060ZRL010M70 1x185 47, MCM 48060ZRL010M71 1x240 49, MCM 48060ZRL010M72 1x300 52, MCM 48060ZRL010M73 1x400 54, MCM 48060ZRL010M74 1x500 58, MCM 48060ZRL010M75 1x630 62, MCM Other dimensions and colours available on request. 18/30 kv 48060XRL010M65 1x50 34, XRL010M66 1x70 36, / XRL010M67 1x95 38, / XRL010M68 1x120 40, / XRL010M69 1x150 41, MCM 48060XRL010M70 1x185 43, MCM 48060XRL010M71 1x240 45, MCM 48060XRL010M72 1x300 47, MCM 48060XRL010M73 1x400 51, MCM 48060XRL010M74 1x500 53, MCM 48060XRL010M75 1x630 60, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 84

94 MEDIUM VOLTAGE CABLES RG7H1(O)M1 Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Nominal voltage: Test voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: according to IEC Temperature range: in service: in short circuit: Resistence: + 90 C C Flame retardant acc.to: IEC DIN VDE 0482 part MEDIUM corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 6/10 kv 48060KR1030M61 3x10 23, KR1030M62 3x16 28,0 460, KR1030M63 3x25 30, KR1030M64 3x35 34, KR1030M65 3x50 36, KR1030M66 3x70 40, / KR1030M67 3x95 43, / KR1030M68 3x120 48, / KR1030M69 3x150 52, MCM 48060KR1030M70 3x185 55, MCM 48060KR1030M71 3x240 62, MCM 48060KR1030M72 3x300 68, MCM 48060KR1030M73 3x400 75, MCM 48060QR1030M61 3x10 37, QR1030M62 3x16 40,0 460, QR1030M63 3x25 42, QR1030M64 3x35 45, QR1030M65 3x50 48, QR1030M66 3x70 52, / QR1030M67 3x95 56, / QR1030M68 3x120 60, / QR1030M69 3x150 63, MCM 48060QR1030M70 3x185 68, MCM 48060QR1030M71 3x240 74, MCM 48060QR1030M72 3x300 79, MCM 48060QR1030M73 3x400 85, MCM 3,6/6 kv 8,7/15 kv 48060MR1030M61 3x10 30, MR1030M62 3x16 32,5 460, MR1030M63 3x25 35, MR1030M64 3x35 37, MR1030M65 3x50 40, MR1030M66 3x70 44, / MR1030M67 3x95 48, / MR1030M68 3x120 52, / MR1030M69 3x150 55, MCM 48060MR1030M70 3x185 59, MCM 48060MR1030M71 3x240 65, MCM 48060MR1030M72 3x300 70, MCM 48060MR1030M73 3x400 77, MCM 48060SR1030M62 3x16 46,0 460, SR1030M63 3x25 50, SR1030M64 3x35 52, SR1030M65 3x50 54, SR1030M66 3x70 58, / SR1030M67 3x95 62, / SR1030M68 3x120 66, / SR1030M69 3x150 70, MCM 48060SR1030M70 3x185 74, MCM 48060SR1030M71 3x240 78, MCM 48060SR1030M72 3x300 85, MCM 85

95 MEDIUM VOLTAGE CABLES RG7H1(O)M1 12/20 kv 18/30 kv 48060UR1030M64 3x35 56, UR1030M65 3x50 58, UR1030M66 3x70 64, / UR1030M67 3x95 67, / UR1030M68 3x120 70, / UR1030M69 3x150 73, MCM 48060UR1030M70 3x185 78, MCM 48060UR1030M71 3x240 84, MCM 48060UR1030M72 3x300 90, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XR1030M65 3x50 73, XR1030M66 3x70 76, / XR1030M67 3x95 81, / XR1030M68 3x120 84, / XR1030M69 3x150 86, MCM 48060XR1030M70 3x185 90, MCM 48060XR1030M71 3x240 96, MCM Other dimensions and colours available on request. 86

96 MEDIUM VOLTAGE CABLES RG7H1NM1 Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper wires and one or two copper tape(s) applied helically aluminium tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: according to IEC Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Resistence: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv + 90 C C Flame retardant acc.to: IEC DIN VDE 0482 part MEDIUM corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 6/10 kv 48070KRL010M61 1x KRL010M62 1x KRL010M63 1x KRL010M64 1x KRL010M65 1x KRL010M66 1x / KRL010M67 1x / KRL010M68 1x / KRL010M69 1x MCM 48070KRL010M70 1x MCM 48070KRL010M71 1x MCM 48070KRL010M72 1x MCM 48070KRL010M73 1x MCM 3,6/6 kv 8,7/15 kv 48070QRL010M61 1x QRL010M62 1x QRL010M63 1x QRL010M64 1x QRL010M65 1x QRL010M66 1x / QRL010M67 1x / QRL010M68 1x / QRL010M69 1x MCM 48070QRL010M70 1x MCM 48070QRL010M71 1x MCM 48070QRL010M72 1x MCM 48070QRL010M73 1x MCM 48070MRL010M61 1x MRL010M62 1x MRL010M63 1x MRL010M64 1x MRL010M65 1x MRL010M66 1x / MRL010M67 1x / MRL010M68 1x / MRL010M69 1x MCM 48070MRL010M70 1x MCM 48070MRL010M71 1x MCM 48070MRL010M72 1x MCM 48070MRL010M73 1x MCM 48070SRL010M62 1x SRL010M63 1x SRL010M64 1x SRL010M65 1x SRL010M66 1x / SRL010M67 1x / SRL010M68 1x / SRL010M69 1x MCM 48070SRL010M70 1x MCM 48070SRL010M71 1x MCM 48070SRL010M72 1x MCM 87

97 MEDIUM VOLTAGE CABLES RG7H1NM1 12/20 kv 18/30 kv 48070URL010M64 1x URL010M65 1x URL010M66 1x / URL010M67 1x / URL010M68 1x / URL010M69 1x MCM 48070URL010M70 1x MCM 48070URL010M71 1x MCM 48070URL010M72 1x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XRL010M65 1x XRL010M66 1x / XRL010M67 1x / XRL010M68 1x / XRL010M69 1x MCM 48070XRL010M70 1x MCM 48070XRL010M71 1x MCM Other dimensions and colours available on request. 88

98 MEDIUM VOLTAGE CABLES RG7H1(O)NM1 Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape steel tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: according to IEC Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Resistence: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv + 90 C C Flame retardant acc.to: IEC DIN VDE 0482 part MEDIUM corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 8,7/15 kv 48070KR1030M61 3x10 29, KR1030M62 3x16 31,0 460, KR1030M63 3x25 34, KR1030M64 3x35 36, KR1030M65 3x50 39, KR1030M66 3x70 43, / KR1030M67 3x95 47, / KR1030M68 3x120 51, / KR1030M69 3x150 54, MCM 48070KR1030M70 3x185 58, MCM 48070KR1030M71 3x240 64, MCM 48070KR1030M72 3x300 77, MCM 48070KR1030M73 3x400 78, MCM 3,6/6 kv 48070QR1030M62 3x16 49,5 460, QR1030M63 3x25 52, QR1030M64 3x35 55, QR1030M65 3x50 57, QR1030M66 3x70 61, / QR1030M67 3x95 65, / QR1030M68 3x120 69, / QR1030M69 3x150 72, MCM 48070QR1030M70 3x185 76, MCM 48070QR1030M71 3x240 82, MCM 48070QR1030M72 3x300 88, MCM 12/20 kv 48070MR1030M61 3x10 33, MR1030M62 3x16 36,5 460, MR1030M63 3x25 39, MR1030M64 3x35 41, MR1030M65 3x50 44, MR1030M66 3x70 48, / MR1030M67 3x95 52, / MR1030M68 3x120 56, / MR1030M69 3x150 59, MCM 48070MR1030M70 3x185 64, MCM 48070MR1030M71 3x240 69, MCM 48070MR1030M72 3x300 76, MCM 48070MR1030M73 3x400 83, MCM 48070SR1030M64 3x35 59, SR1030M65 3x50 62, SR1030M66 3x70 67, / SR1030M67 3x95 70, / SR1030M68 3x120 75, / SR1030M69 3x150 78, MCM 48070SR1030M70 3x185 81, MCM 48070SR1030M71 3x240 88, MCM 48070SR1030M72 3x300 94, MCM 89

99 MEDIUM VOLTAGE CABLES RG7H1(O)NM1 6/10 kv 18/30 kv part no, No,of cores ca,mm approx, no,*) 48070UR1030M61 3x10 41, UR1030M62 3x16 44,0 460, UR1030M63 3x25 47, UR1030M64 3x35 50, UR1030M65 3x50 53, UR1030M66 3x70 57, / UR1030M67 3x95 60, / UR1030M68 3x120 65, / UR1030M69 3x150 68, MCM 48070UR1030M70 3x185 72, MCM 48070UR1030M71 3x240 78, MCM 48070UR1030M72 3x300 84, MCM 48070UR1030M73 3x400 90, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XR1030M65 3x50 76, XR1030M66 3x70 79, / XR1030M67 3x95 83, / XR1030M68 3x120 88, / XR1030M69 3x150 90, MCM 48070XR1030M70 3x185 95, MCM 48070XR1030M71 3x , MCM Other dimensions and colours available on request. 90

100 MEDIUM VOLTAGE CABLES RG7H1ZM1 Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper wires and one or two copper tape(s) applied helically. steel tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: according to IEC Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Resistance: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 8,7/15 kv = 24 kv 3,6/6 kv = 11 kv 12/20 kv= 29 kv 6/10 kv = 17 kv 18/30 kv = 45 kv + 90 C C Flame retardant: acc.to IEC DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 8,7/15 kv 48080KRL010M61 1x KRL010M62 1x KRL010M63 1x KRL010M64 1x KRL010M65 1x KRL010M66 1x / KRL010M67 1x / KRL010M68 1x / KRL010M69 1x MCM 48080KRL010M70 1x MCM 48080KRL010M71 1x MCM 48080KRL010M72 1x MCM 48080KRL010M73 1x MCM 3,6/6 kv 48080QRL010M62 1x QRL010M63 1x QRL010M64 1x QRL010M65 1x QRL010M66 1x / QRL010M67 1x / QRL010M68 1x / QRL010M69 1x MCM 48080QRL010M70 1x MCM 48080QRL010M71 1x MCM 48080QRL010M72 1x MCM 12/20 kv 48080MRL010M61 1x MRL010M62 1x MRL010M63 1x MRL010M64 1x MRL010M65 1x MRL010M66 1x / MRL010M67 1x / MRL010M68 1x / MRL010M69 1x MCM 48080MRL010M70 1x MCM 48080MRL010M71 1x MCM 48080MRL010M72 1x MCM 48080MRL010M73 1x MCM 48080SRL010M64 1x SRL010M65 1x SRL010M66 1x / SRL010M67 1x / SRL010M68 1x / SRL010M69 1x MCM 48080SRL010M70 1x MCM 48080SRL010M71 1x MCM 48080SRL010M72 1x MCM 91

101 MEDIUM VOLTAGE CABLES RG7H1ZM1 6/10 kv 18/30 kv 48080URL010M61 1x URL010M62 1x URL010M63 1x URL010M64 1x URL010M65 1x URL010M66 1x / URL010M67 1x / URL010M68 1x / URL010M69 1x MCM 48080URL010M70 1x MCM 48080URL010M71 1x MCM 48080URL010M72 1x MCM 48080URL010M73 1x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XRL010M65 1x XRL010M66 1x / XRL010M67 1x / XRL010M68 1x / XRL010M69 1x MCM 48080XRL010M70 1x MCM 48080XRL010M71 1x MCM Other dimensions and colours available on request. 92

102 MEDIUM VOLTAGE CABLES RG7H1(O)ZM1 Conductor: Insulation: Screen: Armouring: Outer sheat: stranded red copper conductor Cl. 2, acc to IEC rubber type G7 red copper tape steel tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: according to IEC Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Resistance: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv + 90 C C 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Flame retardant: acc.to IEC DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 8,7/15 kv 48080KR1030M61 3x KR1030M62 3x KR1030M63 3x KR1030M64 3x KR1030M65 3x KR1030M66 3x / KR1030M67 3x / KR1030M68 3x / KR1030M69 3x MCM 48080KR1030M70 3x MCM 48080KR1030M71 3x MCM 48080KR1030M72 3x MCM 48080KR1030M73 3x MCM 3,6/6 kv 48080QR1030M62 3x QR1030M63 3x QR1030M64 3x QR1030M65 3x QR1030M66 3x / QR1030M67 3x / QR1030M68 3x / QR1030M69 3x MCM 48080QR1030M70 3x MCM 48080QR1030M71 3x MCM 48080QR1030M72 3x MCM 12/20 kv 48080MR1030M61 3x MR1030M62 3x MR1030M63 3x MR1030M64 3x MR1030M65 3x MR1030M66 3x / MR1030M67 3x / MR1030M68 3x / MR1030M69 3x MCM 48080MR1030M70 3x MCM 48080MR1030M71 3x MCM 48080MR1030M72 3x MCM 48080MR1030M73 3x MCM 48080SR1030M64 3x SR1030M65 3x SR1030M66 3x / SR1030M67 3x / SR1030M68 3x / SR1030M69 3x MCM 48080SR1030M70 3x MCM 48080SR1030M71 3x MCM 48080SR1030M72 3x MCM 93

103 MEDIUM VOLTAGE CABLES RG7H1(O)ZM1 6/10 kv 18/30 kv 48080UR1030M61 3x UR1030M62 3x UR1030M63 3x UR1030M64 3x UR1030M65 3x UR1030M66 3x / UR1030M67 3x / UR1030M68 3x / UR1030M69 3x MCM 48080UR1030M70 3x MCM 48080UR1030M71 3x MCM 48080UR1030M72 3x MCM 48080UR1030M73 3x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XR1030M65 3x XR1030M66 3x / XR1030M67 3x / XR1030M68 3x / XR1030M69 3x MCM 48080XR1030M70 3x MCM 48080XR1030M71 3x MCM Other dimensions and colours available on request. 94

104 MEDIUM VOLTAGE CABLES RG7H1O(GS)M1 Three-cores, copper tape screen,gaalshock inner sheath,12/20 kv up to 18/30 kv Special GAALSHOCK protection Conductor: Inner semi-conductive layer: Insulation: Outer semi-conductive layer: Screen: Armour: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC extruded compound rubber type G7 strippable cold extruded compound red copper tape GAALTHERM 600 (GAALSHOCK technology) red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: According to IEC Nominal voltage: Test voltage: 12/20 kv up to 18/30 kv 29 kv 43 kv Temperature range: -25 C up to 90 C Max. short circuit temp: C Min. Bending Radius: 12 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC acc. to DIN VDE 0482 part / EN / IEC C Halogen-free: acc. to DIN VDE 0482 part 267, EN / IEC Low smoke density: acc. to IEC , DIN VDE 0482 part , EN /20 kv No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps 48090UR1030M64 3 x 35 58, UR1030M65 3 x 50 61, UR1030M66 3 x 70 63, / UR1030M67 3 x 95 70, / UR1030M68 3 x , / UR1030M69 3 x , MCM 48090UR1030M70 3 x , MCM 48090UR1030M71 3 x , MCM 18/30 kv No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps 48090XR1030M65 3 x 50 74, XR1030M66 3 x 70 78, / XR1030M67 3 x / XR1030M68 3 x , / XR1030M69 3 x , MCM 48090XR1030M70 3 x , MCM 48090XR1030M71 3 x , MCM Other dimension and colors available on request. GAALSHOCK PROTECTION! 1 Excellent mechanical protection than steel 2 Reduced 3 Installation, storage, and transport reduced costs *For GAALSHOCK quality see technical info pag

105 MEDIUM VOLTAGE CABLES RE4H1R (XLPE/CTS/PVC) Conductor: Insulation: Screen: stranded red copper conductor Cl. 2, acc to IEC XLPE compound red copper wires and one or two copper tape(s) applied helically red (RAL 3000),PVC type Rz Nominal voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv Outer sheath: Features: according to IEC Test voltage: Temperature range: in service: in short circuit: Min. bending radius: Resistance: 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv + 90 C C 12 x d 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv 48100KRL010M61 1x10 14, KRL010M62 1x16 15,0 153, KRL010M63 1x25 16, KRL010M64 1x35 17, KRL010M65 1x50 18, KRL010M66 1x70 20, / KRL010M67 1x95 22, / KRL010M68 1x120 24, / KRL010M69 1x150 26, MCM 48100KRL010M70 1x185 27, MCM 48100KRL010M71 1x240 30, MCM 48100KRL010M72 1x300 32, MCM 48100KRL010M73 1x400 35, MCM 48100KRL010M74 1x500 40, MCM 48100KRL010M75 1x630 44, MCM 48100QRL010M61 1x10 19, QRL010M62 1x16 21,0 153, QRL010M63 1x25 22, QRL010M64 1x35 23, QRL010M65 1x50 24, QRL010M66 1x70 26, / QRL010M67 1x95 28, / QRL010M68 1x120 29, / QRL010M69 1x150 31, MCM 48100QRL010M70 1x185 33, MCM 48100QRL010M71 1x240 35, MCM 48100QRL010M72 1x300 38, MCM 48100QRL010M73 1x400 41, MCM 48100QRL010M74 1x500 45, MCM 48100QRL010M75 1x630 48, MCM 3,6/6 kv 8,7/15 kv 48100MRL010M61 1x10 16, MRL010M62 1x16 17,0 153, MRL010M63 1x25 18, MRL010M64 1x35 20, MRL010M65 1x50 21, MRL010M66 1x70 23, / MRL010M67 1x95 25, / MRL010M68 1x120 26, / MRL010M69 1x150 28, MCM 48100MRL010M70 1x185 30, MCM 48100MRL010M71 1x240 32, MCM 48100MRL010M72 1x300 35, MCM 48100MRL010M73 1x400 37, MCM 48100MRL010M74 1x500 41, MCM 48100MRL010M75 1x630 46, MCM 48100SRL010M62 1x16 23,3 153, SRL010M63 1x25 24, SRL010M64 1x35 25, SRL010M65 1x50 27, SRL010M66 1x70 28, / SRL010M67 1x95 30, / SRL010M68 1x120 32, / SRL010M69 1x150 33, MCM 48100SRL010M70 1x185 35, MCM 48100SRL010M71 1x240 38, MCM 48100SRL010M72 1x300 41, MCM 48100SRL010M73 1x400 43, MCM 48100SRL010M74 1x500 47, MCM 48100SRL010M75 1x630 52, MCM 96

106 MEDIUM VOLTAGE CABLES RE4H1R (XLPE/CTS/PVC) 12/20 kv 26/45 kv 48100URL010M64 1x35 27, URL010M65 1x50 29, URL010M66 1x70 30, / URL010M67 1x95 33, / URL010M68 1x120 34, / URL010M69 1x150 36, MCM 48100URL010M70 1x185 37, MCM 48100URL010M71 1x240 40, MCM 48100URL010M72 1x300 43, MCM 48100URL010M73 1x400 45, MCM 48100URL010M74 1x500 50, MCM 48100URL010M75 1x630 54, MCM 48100ZRL010M66 1x70 41, / ZRL010M67 1x95 43, / ZRL010M68 1x120 44, / ZRL010M69 1x150 45, MCM 48100ZRL010M70 1x185 47, MCM 48100ZRL010M71 1x240 49, MCM 48100ZRL010M72 1x300 52, MCM 48100ZRL010M73 1x400 54, MCM 48100ZRL010M74 1x500 58, MCM 48100ZRL010M75 1x630 62, MCM Other dimensions and colours available on request. 18/30 kv 48100XRL010M65 1x50 34, XRL010M66 1x70 36, / XRL010M67 1x95 38, / XRL010M68 1x120 40, / XRL010M69 1x150 41, MCM 48100XRL010M70 1x185 43, MCM 48100XRL010M71 1x240 45, MCM 48100XRL010M72 1x300 47, MCM 48100XRL010M73 1x400 51, MCM 48100XRL010M74 1x500 53, MCM 48100XRL010M75 1x630 60, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 97

107 MEDIUM VOLTAGE CABLES RE4H1(O)R (XLPE/CTS/PVC) Conductor: Insulation: stranded red copper conductor Cl. 2, acc to IEC XLPE compound Nominal voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv Screen: Outer sheath: red copper tape red (RAL 3000),PVC type Rz Test voltage: 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: according to IEC Temperature range: in service: in short circuit: Resistance: + 90 C C Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv 48100KR1030M61 3x10 23, KR1030M62 3x16 28,0 460, KR1030M63 3x25 30, KR1030M64 3x35 34, KR1030M65 3x50 36, KR1030M66 3x70 40, / KR1030M67 3x95 43, / KR1030M68 3x120 48, / KR1030M69 3x150 52, MCM 48100KR1030M70 3x185 55, MCM 48100KR1030M71 3x240 62, MCM 48100KR1030M72 3x300 68, MCM 48100KR1030M73 3x400 75, MCM 3,6/6 kv 48100QR1030M61 3x10 37, QR1030M62 3x16 40,0 460, QR1030M63 3x25 42, QR1030M64 3x35 45, QR1030M65 3x50 48, QR1030M66 3x70 52, / QR1030M67 3x95 56, / QR1030M68 3x120 60, / QR1030M69 3x150 63, MCM 48100QR1030M70 3x185 68, MCM 48100QR1030M71 3x240 74, MCM 48100QR1030M72 3x300 79, MCM 48100QR1030M73 3x400 85, MCM 8,7/15 kv 48100MR1030M61 3x10 30, MR1030M62 3x16 32,5 460, MR1030M63 3x25 35, MR1030M64 3x35 37, MR1030M65 3x50 40, MR1030M66 3x70 44, / MR1030M67 3x95 48, / MR1030M68 3x120 52, / MR1030M69 3x150 55, MCM 48100MR1030M70 3x185 59, MCM 48100MR1030M71 3x240 65, MCM 48100MR1030M72 3x300 70, MCM 48100MR1030M73 3x400 77, MCM 48100SR1030M62 3x16 46,0 460, SR1030M63 3x25 50, SR1030M64 3x35 52, SR1030M65 3x50 54, SR1030M66 3x70 58, / SR1030M67 3x95 62, / SR1030M68 3x120 66, / SR1030M69 3x150 70, MCM 48100SR1030M70 3x185 74, MCM 48100SR1030M71 3x240 78, MCM 48100SR1030M72 3x300 85, MCM 98

108 MEDIUM VOLTAGE CABLES RE4H1(O)R (XLPE/CTS/PVC) 12/20 kv 18/30 kv 48100UR1030M64 3x35 56, UR1030M65 3x50 58, UR1030M66 3x70 64, / UR1030M67 3x95 67, / UR1030M68 3x120 70, / UR1030M69 3x150 73, MCM 48100UR1030M70 3x185 78, MCM 48100UR1030M71 3x240 84, MCM 48100UR1030M72 3x300 90, MCM 48100XR1030M65 3x50 73, XR1030M66 3x70 76, / XR1030M67 3x95 81, / XR1030M68 3x120 84, / XR1030M69 3x150 86, MCM 48100XR1030M70 3x185 90, MCM 48100XR1030M71 3x240 96, MCM Other dimensions and colours available on request. * For cables laying in earth a screen-cross section of 16 mm is permitted. 99

109 MEDIUM VOLTAGE CABLES RE4H1RFR (XLPE/CTS/PVC/AWA/PVC) Conductor: Insulation: Screen: stranded red copper conductor Cl. 2, acc to IEC XLPE compound red copper tape Nominal voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv Inner sheath: Armouring: Outer sheath: PVC compound aluminium wires red(ral 3000),PVC,type RZ Test voltage: Temperature range: in service: in short circuit: 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv + 90 C C 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: according to IEC Min. bending radius: Resistance: 12 x d Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv 48110KRL010M61 1x KRL010M62 1x KRL010M63 1x KRL010M64 1x KRL010M65 1x KRL010M66 1x / KRL010M67 1x / KRL010M68 1x / KRL010M69 1x MCM 48110KRL010M70 1x MCM 48110KRL010M71 1x MCM 48110KRL010M72 1x MCM 48110KRL010M73 1x MCM 48110KRL010M74 1x MCM 48110KRL010M75 1x MCM 48110QRL010M61 1x QRL010M62 1x QRL010M63 1x QRL010M64 1x QRL010M65 1x50 28, QRL010M66 1x / QRL010M67 1x95 31, / QRL010M68 1x120 33, / QRL010M69 1x150 35, MCM 48110QRL010M70 1x185 37, MCM 48110QRL010M71 1x MCM 48110QRL010M72 1x MCM 48110QRL010M73 1x400 45, MCM 48110QRL010M74 1x500 50, MCM 48110QRL010M75 1x630 54, MCM 3,6/6 kv 8,7/15 kv 48110MRL010M61 1x MRL010M62 1x MRL010M63 1x MRL010M64 1x MRL010M65 1x MRL010M66 1x / MRL010M67 1x / MRL010M68 1x / MRL010M69 1x MCM 48110MRL010M70 1x ,7 350 MCM 48110MRL010M71 1x240 37, MCM 48110MRL010M72 1x300 40, ,4 550 MCM 48110MRL010M73 1x400 44, ,8 750 MCM 48110MRL010M74 1x ,4 900 MCM 48110MRL010M75 1x630 53,3-4, MCM 48110SRL010M62 1x SRL010M63 1x SRL010M64 1x SRL010M65 1x50 29, SRL010M66 1x70 32, / SRL010M67 1x95 34, / SRL010M68 1x120 35, / SRL010M69 1x150 37, MCM 48110SRL010M70 1x MCM 48110SRL010M71 1x240 42, MCM 48110SRL010M72 1x300 44, MCM 48110SRL010M73 1x MCM 48110SRL010M74 1x500 52, MCM 48110SRL010M75 1x630 55, MCM 100

110 MEDIUM VOLTAGE CABLES RE4H1RFR (XLPE/CTS/PVC/AWA/PVC) 12/20 kv 26/45 kv 48110URL010M64 1x URL010M65 1x URL010M66 1x70 34, / URL010M67 1x95 36, / URL010M68 1x120 37, / URL010M69 1x150 39, MCM 48110URL010M70 1x MCM 48110URL010M71 1x240 43, MCM 48110URL010M72 1x300 47, MCM 48110URL010M73 1x400 50, MCM 48110URL010M74 1x500 53, MCM 48110URL010M75 1x MCM 48110ZRL010M66 1x / ZRL010M67 1x / ZRL010M68 1x / ZRL010M69 1x MCM 48110ZRL010M70 1x MCM 48110ZRL010M71 1x MCM 48110ZRL010M72 1x MCM 48110ZRL010M73 1x MCM 48110ZRL010M74 1x MCM 48110ZRL010M75 1x MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 18/30 kv 48110XRL010M65 1x50 38, XRL010M66 1x70 39, / XRL010M67 1x95 41, / XRL010M68 1x120 43, / XRL010M69 1x MCM 48110XRL010M70 1x185 47, MCM 48110XRL010M71 1x240 50, MCM 48110XRL010M72 1x300 52, MCM 48110XRL010M73 1x400 56, MCM 48110XRL010M74 1x500 60, MCM 48110XRL010M75 1x MCM Other dimensions and colours available on request. 101

111 MEDIUM VOLTAGE CABLES RE4H1(O)RFR (XLPE/CTS/PVC/SWA/PVC) Conductor: Insulation: Screen: stranded red copper conductor Cl. 2, acc to IEC XLPE compound red copper tape Nominal voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv Inner sheath: Armouring: Outer sheath: PVC compound aluminium wires red(ral 3000),PVC,type RZ Test voltage: 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv Features: according to IEC Temperature range: in service: in short circuit: Resistance: + 90 C C Flame retardant acc. to: DIN VDE 0482 part /EN /IEC ,8/3 kv 6/10 kv part no, No,of cores ca,mm approx, no,*) 48110KR1030M61 3x10 23, KR1030M62 3x16 28, KR1030M63 3x25 30, KR1030M64 3x35 34, KR1030M65 3x50 36, KR1030M66 3x70 40, / KR1030M67 3x95 43, / KR1030M68 3x120 48, / KR1030M69 3x150 52, MCM 48110KR1030M70 3x185 55, MCM 48110KR1030M71 3x240 62, MCM 48110KR1030M72 3x300 68, MCM 48110KR1030M73 3x400 75, MCM 48110QR1030M61 3x10 37, QR1030M62 3x16 40, QR1030M63 3x25 42, QR1030M64 3x35 45, QR1030M65 3x50 48, QR1030M66 3x70 52, / QR1030M67 3x95 56, / QR1030M68 3x120 60, / QR1030M69 3x150 63, MCM 48110QR1030M70 3x185 68, MCM 48110QR1030M71 3x240 74, MCM 48110QR1030M72 3x300 79, MCM 48110QR1030M73 3x400 85, MCM 3,6/6 kv 8,7/15 kv part no, No,of cores ca,mm approx, no,*) part no, No,of cores ca,mm approx, no,*) 48110MR1030M61 3x10 30, MR1030M62 3x16 32, MR1030M63 3x25 35, MR1030M64 3x35 37, MR1030M65 3x50 40, MR1030M66 3x70 44, / MR1030M67 3x95 48, / MR1030M68 3x120 52, / MR1030M69 3x150 55, MCM 48110MR1030M70 3x185 59, MCM 48110MR1030M71 3x240 65, MCM 48110MR1030M72 3x300 70, MCM 48110MR1030M73 3x400 77, MCM 48110SR1030M62 3x16 46, SR1030M63 3x25 50, SR1030M64 3x35 52, SR1030M65 3x50 54, SR1030M66 3x70 58, / SR1030M67 3x95 62, / SR1030M68 3x120 66, / SR1030M69 3x150 70, MCM 48110SR1030M70 3x185 74, MCM 48110SR1030M71 3x240 78, MCM 48110SR1030M72 3x300 85, MCM 102

112 MEDIUM VOLTAGE CABLES RE4H1(O)RFR (XLPE/CTS/PVC/SWA/PVC) 12/20 kv 18/30 kv 48110UR1030M64 3x35 56, UR1030M65 3x50 58, UR1030M66 3x70 64, / UR1030M67 3x95 67, / UR1030M68 3x120 70, / UR1030M69 3x150 73, MCM 48110UR1030M70 3x185 78, MCM 48110UR1030M71 3x240 84, MCM 48110UR1030M72 3x300 90, MCM Other dimensions and colours available on request XR1030M65 3x50 73, XR1030M66 3x70 76, / XR1030M67 3x95 81, / XR1030M68 3x120 84, / XR1030M69 3x150 86, MCM 48110XR1030M70 3x185 90, MCM 48110XR1030M71 3x240 96, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 103

113 MEDIUM VOLTAGE CABLES ARE4H1R Single-core, overall copper wires + tape screen 12/20 kv up to 18/30 kv Conductor: Inner semi-conductive layer: Insulation: Outer semi-conductive layer: Screen: Outer sheath: stranded plain aluminium conductor Cl.2, acc. to IEC extruded compound XLPE compound extruded compound red copper wires and one or two copper tape(s) applied helically. red(ral 3000),PVC,type RZ Nominal voltage: Test voltage: 12/20 kv up to 18/30 kv 12/20 kv = 29 kv 18/30 kv = 43 kv Temperature range: -25 C up to 90 C Max. short circuit temp: C Min. bending radius: 13 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC Features: According to IEC /20 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps Alu 48120URL010M64 1 x 35 26, URL010M65 1 x 50 27, URL010M66 1 x 70 29, / URL010M67 1 x 95 31, / URL010M68 1 x / URL010M69 1 x , MCM 48120URL010M70 1 x , MCM 48120URL010M71 1 x , MCM 48120URL010M72 1 x , MCM 48120URL010M73 1 x , MCM 48120URL010M74 1 x , MCM 48120URL010M75 1 x , MCM 18/30 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps Alu 48120XRL010M65 1 x XRL010M66 1 x 70 34, / XRL010M67 1 x 95 36, / XRL010M68 1x , / XRL010M69 1 x , MCM 48120XRL010M70 1 x , MCM 48120XRL010M71 1 x , MCM 48120XRL010M72 1 x , MCM 48120XRL010M73 1 x , MCM 48120XRL010M74 1 x , MCM 48120XRL010M75 1 x , MCM Other dimension and colors available on request. 104

114 MEDIUM VOLTAGE CABLES ARE4H1RX Three-cores, overall copper wires + tape screen 12/20 kv up to 18/30 kv Conductor: Inner semi-conductive layer: Insulation: Outer semi-conductive layer: Screen: Outer sheath: stranded plain aluminium conductor Cl.2, acc. to IEC extruded compound XLPE compound extruded compound red copper wires and one or two copper tape(s) applied helically. red(ral 3000),PVC,type RZ Nominal voltage: Test voltage: 12/20 kv up to 18/30 kv 12/20 kv = 29 kv 18/30 kv = 43 kv Temperature range: -25 C up to 90 C Max. short circuit temp: C Min. bending radius: 20 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC Features: According to IEC /20 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground P=1 C m/w - P=2 C m/w Amps Alu 48130URL030M64 3 x 1 x 35 56, URL030M65 3 x 1 x 50 58, URL030M66 3 x 1 x 70 62, / URL030M67 3 x 1x 95 66, / URL030M68 3 x 1x , / URL030M69 3 x 1 x , MCM 48130URL030M70 3 x 1 x , MCM 48130URL030M71 3 x 1 x , MCM 48130URL030M72 3 x 1 x , MCM 18/30 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground P=1 C m/w - P=2 C m/w Amps Alu 48130XRL030M65 3 x 1 x 50 70, XRL030M66 3 x 1 x 70 73, / XRL030M67 3 x 1 x 95 77, / XRL030M68 3 x 1x , / XRL030M69 3 x 1 x , MCM 48130XRL030M70 3 x 1 x , MCM 48130XRL030M71 3 x 1 x , MCM 48130XRL030M72 3 x 1 x , MCM Other dimension and colors available on request. 105

115 MEDIUM VOLTAGE CABLES ARE4H5(GS)E Single-core, overall aluminium screen, GAALSHOCK inner sheath 12/20 kv up to 18/30 kv Special GAALSHOCK protection Conductor: stranded plain aluminium conductor Cl.2, acc. to IEC Inner semi-conductive layer: extruded compound Insulation: XLPE type DIX8 Outer semi-conductive layer: extruded compound Wrapping: semi-conductive watertight tape Screen: aluminium tape Armour: GAALTHERM 600 (GAALSHOCK technology) Outer sheath: red(ral 3000),PE type DMP 2 Nominal voltage: Test voltage: Temperature range: 12/20 kv up to 18/30 kv 12/20 kv = 29 kv 18/30 kv = 43 kv -25 C up to +90 C Max. short circuit temp: C Min. bending radius: 13 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC Features: According to IEC and HD /20 kv 18/30 kv No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps Alu 48140URL010M65 1 x 50 34, URL010M66 1 x 70 35, / URL010M67 1 x / URL010M68 1x , / URL010M69 1 x , MCM 48140URL010M70 1 x , MCM 48140URL010M71 1 x MCM 48140URL010M72 1 x , MCM 48140URL010M73 1 x , MCM 48140URL010M74 1 x , MCM 48140URL010M75 1 x , MCM No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground trefoil P=1 C m/w - P=2 C m/w Amps Alu 48140XRL010M65 1 x 50 40, XRL010M66 1 x 70 40, / XRL010M67 1 x 95 41, / XRL010M68 1x , / XRL010M69 1 x , MCM 48140XRL010M70 1 x , MCM 48140XRL010M71 1 x , MCM 48140XRL010M72 1 x , MCM 48140XRL010M73 1 x , MCM 48140XRL010M74 1 x , MCM 48140XRL010M75 1 x MCM Other dimension and colors available on request. 106 GAALSHOCK PROTECTION! 1 Excellent mechanical protection than steel 2 Reduced 3 Installation, storage, and transport reduced costs

116 MEDIUM VOLTAGE CABLES ARE4H5(GS)EX Three-cores, overall aluminium screen, GAALSHOCK inner sheath 12/20 kv up to 18/30 kv Special GAALSHOCK protection Conductor: stranded plain aluminium conductor Cl. 2, acc. to IEC Inner semi-conductive layer: extruded compound Insulation: XLPE type DIX8 Outer semi-conductive layer: extruded compound Wrapping: semi-conductive watertight tape Screen: aluminium tape Inner sheath: GAALTHERM 600 (GAALSHOCK technology) Outer sheath: red(ral 3000),PE type DMP 2 Nominal voltage: Test voltage: 12/20 kv up to 18/30 kv 12/20 kv = 29 kv 18/30 kv = 43 kv Temperature range: -25 C up to 90 C Max. short circuit temp: C Min. bending radius: 20 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC Features: According to IEC and HD /20 kv No. of cores Ca. mm Current capacity in air Amps Current capacity underground P=1 C m/w - P=2 C m/w Amps Alu 48150UR1030M65 3 x 1 x 50 34, UR1030M66 3 x 1 x 70 35, / UR1030M67 3 x 1 x / UR1030M68 3 x 1x , / UR1030M69 3 x 1 x , MCM 48150UR1030M70 3 x 1 x , MCM 48150UR1030M71 3 x 1 x MCM 48150UR1030M72 3 x 1 x , MCM 18/30 kv No. of cores Ca. mm Current capacity in air trefoil Amps Current capacity underground P=1 C m/w - P=2 C m/w Amps Alu 48150XR1030M65 3 x 1 x 50 40, XR1030M66 3 x 1 x 70 40, / XR1030M67 3 x 1 x 95 41, / XR1030M68 3 x 1x , / XR1030M69 3 x 1 x , MCM 48150XR1030M70 3 x 1 x , MCM 48150XR1030M71 3 x 1 x , MCM 48150XR1030M72 3 x 1 x , MCM Other dimension and colors available on request. GAALSHOCK PROTECTION! 1 Excellent mechanical protection than steel 2 Reduced 3 Installation, storage, and transport reduced costs 107

117 MEDIUM VOLTAGE CABLES RE4H1M1 (XLPE/CTS/LS0H) Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC XLPE compound red copper wires and one or two copper tape(s) applied helically. red (RAL 3000),PVC type Rz Nominal voltage: Test voltage: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv 1,8/3 kv Features: according to IEC Temperature range: in service: in short circuit: Resistance: 6/10 kv + 90 C C Flame retardant acc. to: DIN VDE 0482 part /EN /IEC corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part KRL010M61 1x10 14, KRL010M62 1x16 15,0 153, KRL010M63 1x25 16, KRL010M64 1x35 17, KRL010M65 1x50 18, KRL010M66 1x70 20, / KRL010M67 1x95 22, / KRL010M68 1x120 24, / KRL010M69 1x150 26, MCM 48160KRL010M70 1x185 27, MCM 48160KRL010M71 1x240 30, MCM 48160KRL010M72 1x300 32, MCM 48160KRL010M73 1x400 35, MCM 48160KRL010M74 1x500 40, MCM 48160KRL010M75 1x630 44, MCM 3,6/6 kv 8,7/15 kv 48160QRL010M61 1x10 19, QRL010M62 1x16 21,0 153, QRL010M63 1x25 22, QRL010M64 1x35 23, QRL010M65 1x50 24, QRL010M66 1x70 26, / QRL010M67 1x95 28, / QRL010M68 1x120 29, / QRL010M69 1x150 31, MCM 48160QRL010M70 1x185 33, MCM 48160QRL010M71 1x240 35, MCM 48160QRL010M72 1x300 38, MCM 48160QRL010M73 1x400 41, MCM 48160QRL010M74 1x500 45, MCM 48160QRL010M75 1x630 48, MCM MRL010M61 1x10 16, MRL010M62 1x16 17,0 153, MRL010M63 1x25 18, MRL010M64 1x35 20, MRL010M65 1x50 21, MRL010M66 1x70 23, / MRL010M67 1x95 25, / MRL010M68 1x120 26, / MRL010M69 1x150 28, MCM 48160MRL010M70 1x185 30, MCM 48160MRL010M71 1x240 32, MCM 48160MRL010M72 1x300 35, MCM 48160MRL010M73 1x400 37, MCM 48160MRL010M74 1x500 41, MCM 48160MRL010M75 1x630 46, MCM 48160SRL010M62 1x16 23,3 153, SRL010M63 1x25 24, SRL010M64 1x35 25, SRL010M65 1x50 27, SRL010M66 1x70 28, / SRL010M67 1x95 30, / SRL010M68 1x120 32, / SRL010M69 1x150 33, MCM 48160SRL010M70 1x185 35, MCM 48160SRL010M71 1x240 38, MCM 48160SRL010M72 1x300 41, MCM 48160SRL010M73 1x400 43, MCM 48160SRL010M74 1x500 47, MCM 48160SRL010M75 1x630 52, MCM

118 MEDIUM VOLTAGE CABLES RE4H1M1 (XLPE/CTS/LS0H) 12/20 kv 26/45 kv 48160URL010M64 1x35 27, URL010M65 1x50 29, URL010M66 1x70 30, / URL010M67 1x95 33, / URL010M68 1x120 34, / URL010M69 1x150 36, MCM 48160URL010M70 1x185 37, MCM 48160URL010M71 1x240 40, MCM 48160URL010M72 1x300 43, MCM 48160URL010M73 1x400 45, MCM 48160URL010M74 1x500 50, MCM 48160URL010M75 1x630 54, MCM 48160ZRL010M66 1x70 41, / ZRL010M67 1x95 43, / ZRL010M68 1x120 44, / ZRL010M69 1x150 45, MCM 48160ZRL010M70 1x185 47, MCM 48160ZRL010M71 1x240 49, MCM 48160ZRL010M72 1x300 52, MCM 48160ZRL010M73 1x400 54, MCM 48160ZRL010M74 1x500 58, MCM 48160ZRL010M75 1x630 62, MCM Other dimensions and colours available on request. 18/30 kv 48160XRL010M65 1x50 34, XRL010M66 1x70 36, / XRL010M67 1x95 38, / XRL010M68 1x120 40, / XRL010M69 1x150 41, MCM 48160XRL010M70 1x185 43, MCM 48160XRL010M71 1x240 45, MCM 48160XRL010M72 1x300 47, MCM 48160XRL010M73 1x400 51, MCM 48160XRL010M74 1x500 53, MCM 48160XRL010M75 1x630 60, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 109

119 MEDIUM VOLTAGE CABLES RE4H1(O)M1 (XLPE/CTS/LS0H) Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC XLPE compound red copper tape red (RAL 3000),thermoplastic polyolefine, halogen-free,type M1 Features: according to IEC Nominal voltage: Test voltage: Temperature range: in service: in short circuit: Resistance: 1,8/3 kv, 3,6/6 kv, 6/10 kv 8,7/15 kv, 12/20 kv 18/30 kv, 26/45 kv 1,8/3 kv = 6 kv 3,6/6 kv = 11 kv 6/10 kv = 17 kv 8,7/15 kv = 24 kv 12/20 kv= 29 kv 18/30 kv = 45 kv + 90 C C Flame retardant: acc.to IEC DIN VDE 0482 part Halogen free: I EN , IEC DIN VDE 0482 part ,8/3 kv 6/10 kv 48160KR1030M61 3x10 23, KR1030M62 3x16 28,0 460, KR1030M63 3x25 30, KR1030M64 3x35 34, KR1030M65 3x50 36, KR1030M66 3x70 40, / KR1030M67 3x95 43, / KR1030M68 3x120 48, / KR1030M69 3x150 52, MCM 48160KR1030M70 3x185 55, MCM 48160KR1030M71 3x240 62, MCM 48160KR1030M72 3x300 68, MCM 48160KR1030M73 3x400 75, MCM 3,6/6 kv 48160QR1030M61 3x10 37, QR1030M62 3x16 40,0 460, QR1030M63 3x25 42, QR1030M64 3x35 45, QR1030M65 3x50 48, QR1030M66 3x70 52, / QR1030M67 3x95 56, / QR1030M68 3x120 60, / QR1030M69 3x150 63, MCM 48160QR1030M70 3x185 68, MCM 48160QR1030M71 3x240 74, MCM 48160QR1030M72 3x300 79, MCM 48160QR1030M73 3x400 85, MCM 8,7/15 kv 48160MR1030M61 3x10 30, MR1030M62 3x16 32,5 460, MR1030M63 3x25 35, MR1030M64 3x35 37, MR1030M65 3x50 40, MR1030M66 3x70 44, / MR1030M67 3x95 48, / MR1030M68 3x120 52, / MR1030M69 3x150 55, MCM 48160MR1030M70 3x185 59, MCM 48160MR1030M71 3x240 65, MCM 48160MR1030M72 3x300 70, MCM 48160MR1030M73 3x400 77, MCM 48160SR1030M62 3x16 46,0 460, SR1030M63 3x25 50, SR1030M64 3x35 52, SR1030M65 3x50 54, SR1030M66 3x70 58, / SR1030M67 3x95 62, / SR1030M68 3x120 66, / SR1030M69 3x150 70, MCM 48160SR1030M70 3x185 74, MCM 48160SR1030M71 3x240 78, MCM 48160SR1030M72 3x300 85, MCM 110

120 MEDIUM VOLTAGE CABLES RE4H1(O)M1 (XLPE/CTS/LS0H) 12/20 kv 18/30 kv 48160UR1030M64 3x35 56, UR1030M65 3x50 58, UR1030M66 3x70 64, / UR1030M67 3x95 67, / UR1030M68 3x120 70, / UR1030M69 3x150 73, MCM 48160UR1030M70 3x185 78, MCM 48160UR1030M71 3x240 84, MCM 48160UR1030M72 3x300 90, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted XR1030M65 3x50 73, XR1030M66 3x70 76, / XR1030M67 3x95 81, / XR1030M68 3x120 84, / XR1030M69 3x150 86, MCM 48160XR1030M70 3x185 90, MCM 48160XR1030M71 3x240 96, MCM Other dimensions and colours available on request. 111

121 MEDIUM VOLTAGE CABLES NSGAFÖU 3 kv Special rubber insulated cable Conductor: Insulation: Outer sheath: flexible tinned copper conductor Cl. 5, acc to IEC 60228, DIN VDE 0295 rubber type 3GI3, halogen free black(ral 9005),rubber type,5gm3 Features: Ozone resistance UV resistance Applications: This insulated wire is designed for application busses and railborn veichles. if used in distribution or switching appliances the wire is considered to be short circuit proof. the cable is halogen-free, flame retardant and resistant against moist oils and grease. Nominal voltage: 1,8/3,6 kv Test voltage: 6 kv Temperature range: fixed laying: -40 / +90 C flexible application: -25 / +90 C max. temp on conductor : +90 C Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN ,IEC copper 48170K7L010M15 1x1,5 SW 5,5 14, K7L010M25 1x2,5 SW 5,9 24, K7L010M40 1x4 SW 6,4 38, K7L010M60 1x6 SW 7,0 58, K7L010M61 1x10 SW 8,4 96, K7L010M62 1x16 SW 9,2 154, K7L010M63 1x25 SW 11,5 240, K7L010M64 1x35 SW 12,8 336, K7L010M65 1x50 SW 14,3 480,0 1 copper 48170K7L010M66 1x70 SW 16,0 672, / K7L010M67 1x95 SW 18,2 912, / K7L010M68 1x120 SW 19,9 1152, / K7L010M69 1x150 SW 21,8 1440, MCM 48170K7L010M70 1x185 SW 23,8 1776, MCM 48170K7L010M71 1x240 SW 26,7 2304, MCM 48170K7L010M72 1x300 SW 38,0 2880, MCM 48170K7L010M73 1x400 SW 40,5 3840, MCM 48170K7L010M74 1x500 SW 42,0 4800, MCM Other dimensions and colours available on request. 112

122 MEDIUM VOLTAGE CABLES NSHXAFÖ 3 kv Special rubber insulated cable Conductor: Insulation: Outer sheath: flexible tinned copper conductor Cl. 5, acc to IEC 60228, DIN VDE 0295 rubber type 3GI3, halogen free black(ral 9005),rubber type,5gm3 Nominal voltage: Test voltage: Temperature range: fixed laying: flexible application: 1,8/3,6 kv 6 kv -40 / -70 C -25 / -70 C Applications: This insulated wire is designed for application busses and railborn veichles. if used in distribution or switching appliances up to 1000 V, it is considered to be short circuit proof. the cable is halogen-free, flame retardant and resistant against moist oils and grease. Resistance: Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN , IEC Halogen free acc. to: IEC , EN DIN VDE 0482 part Oil resistant acc. to: IEC , DIN VDE 0473 part Alu 48180K7L010M15 1x1.5 7,0 14, K7L010M25 1x2.5 7,5 24, K7L010M40 1x4 9,0 38, K7L010M60 1x6 9,5 58, K7L010M61 1x10 11,0 96, K7L010M62 1x16 13,0 154, K7L010M63 1x25 15,0 240, K7L010M64 1x35 16,5 336, K7L010M65 1x50 18,0 480, Alu 48180K7L010M66 1x70 20,5 672, / K7L010M67 1x95 24,0 912, / K7L010M68 1x120 25,1 1152, / K7L010M69 1x150 28,0 1440, MCM 48180K7L010M70 1x185 31,0 1776, MCM 48180K7L010M71 1x240 34,5 2304, MCM 48180K7L010M72 1x300 38,0 2880, MCM 48180K7L010M73 1x400 40,1 3840, MCM 48180K7L010M74 1x500 42,1 4800, MCM Other dimensions and colours available on request. 113

123 MEDIUM VOLTAGE CABLES N2XSY 6/10 kv, 12/20 kv, 18/30 kv PVC- jacket Conductor: Insulation: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC DIN VDE 0295 XLPE compound red copper wires and one or two copper tape(s) applied helically red(ral 3000),PVC compound Applications: Nominal voltage: Test voltage: Temperature range: Resistance: 6/10 kv, 12/20 kv, 18/30 kv 6/10 kv = 15 kv 12/20 kv = 30 kv 18/30 kv = 45 kv - 5 C +70 C Flame retardant: and sel-extinguishing acc.to: DIN VDE 0482 part /EN /IEC Suitable for installation mostly for power supply stations, in indoors and in cable ducts, outdoors, underground, and in water as well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristics, this can also be laid easily in difficult line guideways. See DIN VDE 0298 part 1. 6/10 kv 18/30 kv 48190QRL010M64 1x35 rm/16 25, QRL010M65 1x50 rm/16 26, QRL010M66 1x70 rm/16 28, / QRL010M67 1x95 rm/16 29, / QRL010M68 1x120 rm/16 31, / QRL010M69 1x150 rm/16* 32, MCM 48190QRL010M69 1x150 rm/25 32, MCM 48191QRL011M70 1x185 rm/16* 36, MCM 48190QRL010M70 1x185 rm/25 36, MCM 48191QRL011M71 1x240 rm/16* 38, MCM 48190QRL010M71 1x240 rm/25 38, MCM 48190QRL010M72 1x300 rm/25 38, MCM 48190QRL010M73 1x400 rm/35 42, MCM 48190QRL010M74 1x500 rm/ MCM 48190XRL010M65 1x50 rm/16 35, XRL010M66 1x70 rm/16 37, / XRL010M67 1x95 rm/16 38, / XRL010M68 1x120 rm/16 40, / XRL010M69 1x150 rm/25 41, MCM 48190XRL010M70 1x185 rm/25 43, MCM 48190XRL010M71 1x240 rm/25 45, MCM 48190XRL010M72 1x300 rm/25 48, MCM 48190XRL010M73 1x400 rm/35 51, MCM 48190XRL010M74 1x500 rm/35 54, MCM Other dimensions and colours available on request. 12/20 kv 48190URL010M64 1x35 rm/16 29, URL010M65 1x50 rm/16 20, URL010M66 1x70 rm/16 32, / URL010M67 1x95 rm/16 33, / URL010M68 1x120 rm/16 35, / URL011M69 1x150 rm/16* 36, MCM 48190URL010M69 1x150 rm/25 36, MCM 48191URL011M70 1x185 rm/16* 38, MCM 48190URL010M70 1x185 rm/25 38, MCM 48191URL011M71 1x240 rm/16* 41, MCM 48190URL010M71 1x240 rm/25 41, MCM 48190URL010M72 1x300 rm/25 43, MCM 48190URL010M73 1x400 rm/35 46, MCM 48190URL010M74 1x500 rm/35 49, MCM 114 * For cables laying in earth a screen-cross section of 16 mm is permitted.

124 MEDIUM VOLTAGE CABLES N2XS2Y 6/10 kv, 12/20 kv, 18/30 kv PE- jacket Conductor: Conductor screen: Insulation: stranded red copper conductor Cl. 2, acc to IEC DIN VDE 0295 semi-conductive compound XLPE,type DIX 8 Nominal voltage: Nominal voltage: Test Testing voltage: voltage: 6/10 kv, 12/20 kv, 18/30 kv 6/10 kv = 15 kv 12/20 kv = 30 kv 18/30 kv = 45 kv Core screen: Screen: Outher sheath: semi-conductive compound red copper wires and one or two copper tape(s) applied helically black (RAL 9005),PE Applications: Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installations in cable trays for industries, switchboards and power station. The PE outer jacket is resistant to high mechanical stress for laying the cables. This PE jacket is not flame-resistant (does not conform the test method B, as per VDE 0472 part 804). Temperature range: Min. Temperature bending radius: range: Resistance: fixed laying: flexible application: max. temp on conductor: Flame retardant: - 20 C +70 C 15 x d Flame retardant: acc.to IEC DIN VDE 0482 part /10 kv 12/20 kv 48200Q7L010M64 1x35 rm/16 25, Q7L010M65 1x50 rm/16 26, Q7L010M66 1x70 rm/16 28, / Q7L010M67 1x95 rm/16 29, / Q7L010M68 1x120 rm/16 31, / Q7L010M69 1x150 rm/16* 32, MCM 48200Q7L010M69 1x150 rm/25 32, MCM 48201Q7L011M70 1x185 rm/16* 34, MCM 48200Q7L010M70 1x185 rm/25 34, MCM 48201Q7L011M71 1x240 rm/16* 36, MCM 48200Q7L010M71 1x240 rm/25 36, MCM 48200Q7L010M72 1x300 rm/25 38, MCM 48200Q7L010M73 1x400 rm/35 42, MCM 48200Q7L010M74 1x500 rm/35 45, MCM 48200U7L010M64 1x35 rm/16 29, U7L010M65 1x50 rm/16 30, U7L010M66 1x70 rm/16 32, / U7L010M67 1x95 rm/16 33, / U7L010M68 1x120 rm/16 35, / U7L011M69 1x150 rm/16* 36, MCM 48200U7L010M69 1x150 rm/25 36, MCM 48201U7L011M70 1x185 rm/16* 38, MCM 48200U7L010M70 1x185 rm/25 38, MCM 48201U7L011M71 1x240 rm/16* 41, MCM 48200U7L010M71 1x240 rm/25 41, MCM 48200U7L010M72 1x300 rm/25 43, MCM 48200U7L010M73 1x400 rm/35 46, MCM 48200U7L010M74 1x500 rm/35 49, MCM 115

125 MEDIUM VOLTAGE CABLES N2XS2Y 6/10 kv, 12/20 kv, 18/30 kv PE- jacket 18/30 kv 48200X7L010M65 1x50 rm/16 35, X7L010M66 1x70 rm/16 37, / X7L010M67 1x95 rm/16 38, / X7L010M68 1x120 rm/16 40, / X7L010M69 1x150 rm/25 41, MCM 48200X7L010M70 1x185 rm/25 43, MCM 48200X7L010M71 1x240 rm/25 45, MCM 48200X7L010M72 1x300 rm/25 48, MCM 48200X7L010M73 1x400 rm/35 51, MCM 48200X7L010M74 1x500 rm/35 54, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. 116

126 MEDIUM VOLTAGE CABLES N2XS(F)2Y 6/10 kv, 12/20 kv, 18/30 kv.pe- jacket and WATER TIGHT Conductor: Insulation: Insulation: stranded red copper conductor Cl. 2, acc to IEC DIN VDE 0295 XLPE compound Nominal voltage: Nominal voltage: Test Testing voltage: voltage: 6/10 kv, 12/20 kv, 18/30 kv 6/10 kv = 15 kv 12/20 kv = 30 kv 18/30 kv = 45 kv Outher Screen: sheath: Wrapping: Outer sheath: red copper wires and one or two copper tape(s) applied helically. semi-conductive watertight tape black (RAL 9005),PE type DMP2 Applications: Temperature range: Temperature range: Max. operating temp. on fixed conductor: laying: flexible application: max. temp on conductor: Resistance: Flame retardant: - 20 C/+70 C +90 C Flame retardant: acc.to IEC DIN VDE 0482 part Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installations in cable trays for industries, switchboards and power station. 6/10 kv 18/30 kv Cab1e 48210Q7L010M64 1x35 rm/ Q7L010M65 1x50 rm/ Q7L010M66 1x70 rm/ / Q7L010M67 1x95 rm/ / Q7L010M68 1x120 rm/ / Q7L010M69 1x150 rm/ MCM 48210Q7L010M70 1x185 rm/ MCM 48210Q7L010M71 1x240 rm/ MCM 48210Q7L010M72 1x300 rm/ MCM 48210Q7L010M73 1x400 rm/ MCM 48210Q7L010M74 1x500 rm/ MCM 12/20 kv 48210X7L010M64 1x35 rm/ X7L010M65 1x50 rm/ X7L010M66 1x70 rm/ / X7L010M67 1x95 rm/ / X7L010M68 1x120 rm/ / X7L010M69 1x150 rm/ MCM 48210X7L010M70 1x185 rm/ MCM 48210X7L010M71 1x240 rm/ MCM 48210X7L010M72 1x300 rm/ MCM 48210X7L010M73 1x400 rm/ MCM 48210X7L010M74 1x500 rm/ MCM Other dimensions and colours available on request U7L010M64 1x35 rm/ U7L010M65 1x50 rm/ U7L010M66 1x70 rm/ / U7L010M67 1x95 rm/ / U7L010M68 1x120 rm/ / U7L010M69 1x150 rm/ MCM 48210U7L010M70 1x185 rm/ MCM 48210U7L010M71 1x240 rm/ MCM 48210U7L010M72 1x300 rm/ MCM 48210U7L010M73 1x400 rm/ MCM 48210U7L010M74 1x500 rm/ MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 117

127 MEDIUM VOLTAGE CABLES N2XSEY 6/10, 12/20 and 18/30 kv XLPE-Insulated,PVC Jacket Conductor : Insulation: screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC DIN VDE 0295 XLPE compound red copper wires and one or two copper tape(s) applied helically. red(ral 3000),PVC,type YM5 Nominal voltage: Test voltage: Temperature range: Resistance: 6/10 kv 15 kv during installation up to - 5 C Flame retardant: acc.to IEC DIN VDE 0482 part Applications: High operational reliability is assured by the combination of both conducting layers in combination with the insulation. Suitable for installation in indoors and in cable ducts,outdoor as well as for laying on racks for industry and switching systems and power plants. 6/10 kv 18/30 kv 48220QR1030M61 3x10 rm/10 36, QR1030M62 3x16 rm 16 39, QR1030M63 3x25 rm/16 43, QR1030M64 3x35 rm/16 48, QR1030M65 3x50 rm/16 50, QR1030M66 3x70 rm/16 54, / QR1030M67 3x95 rm/16 58, / QR1030M68 3x120 rm/16 61, / QR1030M69 3x150 rm/25 65, MCM 48220QR1030M70 3x185 rm/25 68, MCM 48220QR1030M71 3x240 rm/25 74, MCM 48220QR1030M72 3x300 rm/25 79, MCM 48220QR1030M73 3x400 rm/35 83, MCM 48220QR1030M74 3x500 rm/35 91, MCM 12/20 kv 48220XR1030M64 3x35 rm/16 65, XR1030M65 3x50 rm/16 69, XR1030M66 3x70 rm/16 72, / XR1030M67 3x95 rm/16 76, / XR1030M68 3x120 rm/16 79, / XR1030M69 3x150 rm/25 82, MCM 48220XR1030M70 3x185 rm/25 87, MCM 48220XR1030M71 3x240 rm/25 91, MCM 48220XR1030M72 3x300 rm/25 98, MCM Other dimensions and colours available on request UR1030M63 3x25 rm/16 51, UR1030M64 3x35 rm/16 54, UR1030M65 3x50 rm/16 57, UR1030M66 3x70 rm/16 61, / UR1030M67 3x95 rm/16 64, / UR1030M68 3x120 rm/16 68, / UR1030M69 3x150 rm/25 71, MCM 48220UR1030M70 3x185 rm/25 75, MCM 48220UR1030M71 3x240 rm/25 80, MCM 48220UR1030M72 3x300 rm/25 87, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 118

128 MEDIUM VOLTAGE CABLES NF2XSE(GS)Y Three-cores, copper wires screen, GAALSHOCK inner sheath, 3,6/6 kv up to 18/30 kv Special GAALSHOCK protection Conductor: Inner semi-conductive layer: Insulation: Outer semi-conductive layer: Screen: Inner sheath: Outer sheath: copper or aluminium strands conductor Cl. 2, acc. to IEC on request water blocked conductor extruded compound XLPE compound or HEPR compound extruded compound copper wires, on request water blocking screen GAALTHERM 600 (GAALSHOCK technology) red(ral 3000),PVC compound Features: According to IEC UV, weather, chemical and water resistance on request acc. to SPLN, IA/NEMA on request PVC-FR compound (flame retardant), LS0H or PE compound, other colors on request Nominal voltage: Test voltage: 3,6/6 kv (7200)V up to 1,8/3 kv (3600)V 3,6/6 (7200)V = 6000 V 6/10 (12000)V =11000 V 8,7/15(1750)V = V 12/20 (24000)V = V 18/30 (36000)V = V Temperature range: -25 C up to 90 C Max. short circuit temp: C Min. Bending Radius: during installation: 20 x d in operation: 15 x d Resistance: Self-extinguishing and flame retardant: acc. to DIN VDE 0482 part / EN / IEC acc. to DIN VDE 0482 part / EN / IEC C 3,6/6 (7,2) kv COPPER CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores Ca. mm Current capacity in ground Amps Current capacity in ducts Amps Current capacity in air Amps 48230MR1030M65 3 x 1 x MR1030M66 3 x 1 x / MR1030M67 3 x 1 x / MR1030M68 3 x 1 x / MR1030M69 3 x 1 x MCM 48230MR1030M70 3 x 1 x MCM 48230MR1030M71 3 x1 x MCM 48230MR1030M72 3 x 1 x MCM 48230MR1030M73 3 x 1 x MCM 6/10 (12) kv COPPER CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores Ca. mm Current capacity in ground Amps Current capacity in ducts Amps Current capacity in air Amps 48230QR1030M65 3 x 1 x QR1030M66 3 x 1 x / QR1030M67 3 x 1 x / QR1030M68 3 x 1 x / QR1030M69 3 x 1 x MCM 48230QR1030M70 3 x 1 x MCM 48230QR1030M71 3 x1 x MCM 48230QR1030M72 3 x 1 x MCM 48230QR1030M73 3 x 1 x MCM 119

129 MEDIUM VOLTAGE CABLES NF2XSE(GS)Y Three-cores, copper wires screen, GAALSHOCK inner sheath, 3,6/6 kv up to 18/30 kv Special GAALSHOCK protection 8,7/15 (17,5) kv COPPER CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores Ca. mm Current capacity in ground Amps Current capacity in ducts Amps Current capacity in air Amps 48230SR1030M65 3 x 1 x SR1030M66 3 x 1 x / SR1030M67 3 x 1 x / SR1030M68 3 x 1 x / SR1030M69 3 x 1 x MCM 48230SR1030M70 3 x 1 x MCM 48230SR1030M71 3 x1 x MCM 48230SR1030M72 3 x 1 x MCM 48230SR1030M73 3 x 1 x MCM 12/20 (24) kv COPPER CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH 18/30 (36) kv COPPER CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores No. of cores Ca. mm Ca. mm Current capacity in ground Amps Current capacity in ground Amps Current capacity in ducts Amps Current capacity in ducts Amps Current capacity in air Amps Current capacity in air Amps 48230UR1030M65 3 x 1 x UR1030M66 3 x 1 x / UR1030M67 3 x 1 x / UR1030M68 3 x 1 x / UR1030M69 3 x 1 x MCM 48230UR1030M70 3 x 1 x MCM 48230UR1030M71 3 x1 x MCM 48230UR1030M72 3 x 1 x MCM 48230UR1030M73 3 x 1 x MCM 48230XR1030M65 3 x 1 x XR1030M66 3 x 1 x / XR1030M67 3 x 1 x / XR1030M68 3 x 1 x / XR1030M69 3 x 1 x MCM 48230XR1030M70 3 x 1 x MCM 48230XR1030M71 3 x1 x MCM 48230XR1030M72 3 x 1 x MCM 48230XR1030M73 3 x 1 x MCM 120

130 MEDIUM VOLTAGE CABLES NF2XSE(GS)Y Three-cores, copper wires screen, GAALSHOCK inner sheath, 3,6/6 kv up to 18/30 kv Special GAALSHOCK protection 3,6/6 (7,2) kv ALUMINIUM CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH 6/10 (12) kv ALUMINIUM CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores Ca. mm Current capacity in ground Amps Current capacity in ducts Amps Current capacity in air Amps Amps Amps Amps 48231SR1030M65 3 x 1 x SR1030M66 3 x 1 x / SR1030M67 3 x 1 x / SR1030M68 3 x 1 x / SR1030M69 3 x 1 x MCM 48231SR1030M70 3 x 1 x MCM 48231SR1030M71 3 x1 x MCM 48231SR1030M72 3 x 1 x MCM 48231SR1030M73 3 x 1 x MCM 12/20 (24) kv ALUMINIUM CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH 48231QR1030M65 3 x 1 x QR1030M66 3 x 1 x / QR1030M67 3 x 1 x / QR1030M68 3 x 1 x / QR1030M69 3 x 1 x MCM 48231QR1030M70 3 x 1 x MCM 48231QR1030M71 3 x1 x MCM 48231QR1030M72 3 x 1 x MCM 48231QR1030M73 3 x 1 x MCM 8,7/15 (17,5) kv ALUMINIUM CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores No. of cores Ca. mm Ca. mm Current capacity in ground Amps Current capacity in ground Amps Current capacity in ducts Amps Current capacity in ducts Amps Current capacity in air Amps Current capacity in air Amps 48231UR1030M65 3 x 1 x UR1030M66 3 x 1 x / UR1030M67 3 x 1 x / UR1030M68 3 x 1 x / UR1030M69 3 x 1 x MCM 48231UR1030M70 3 x 1 x MCM 48231UR1030M71 3 x1 x MCM 48231UR1030M72 3 x 1 x MCM 48231UR1030M73 3 x 1 x MCM 48231MR1030M65 3 x 1 x MR1030M66 3 x 1 x / MR1030M67 3 x 1 x / MR1030M68 3 x 1 x / MR1030M69 3 x 1 x MCM 48231MR1030M70 3 x 1 x MCM 48231MR1030M71 3 x1 x MCM 48231MR1030M72 3 x 1 x MCM 48231MR1030M73 3 x 1 x MCM No. of cores Ca. mm Current capacity in ground Current capacity in ducts Current capacity in air 121

131 MEDIUM VOLTAGE CABLES NF2XSE(GS)Y Three-cores, copper wires screen, GAALSHOCK inner sheath, 3,6/6 kv up to 18/30 kv Special GAALSHOCK protection 18/30 (36) kv ALUMINIUM CONDUCTOR, XLPE INSULATION, COPPER WIRES SCREEN, GAALSHOCK INNER SHEATH, PVC OUTER SHEATH No. of cores Ca. mm Current capacity in ground Amps Current capacity in ducts Amps Current capacity in air Amps 48231XR1030M65 3 x 1 x XR1030M66 3 x 1 x / XR1030M67 3 x 1 x / XR1030M68 3 x 1 x / XR1030M69 3 x 1 x MCM 48231XR1030M70 3 x 1 x MCM 48231XR1030M71 3 x1 x MCM 48231XR1030M72 3 x 1 x MCM 48231XR1030M73 3 x 1 x MCM Other dimension and colors available on request. GAALSHOCK PROTECTION! 1 Excellent mechanical protection than steel 2 Reduced 3 Installation, storage, and transport reduced costs 122

132 MEDIUM VOLTAGE CABLES NA2XSY 6/10 kv, 12/20 kv, 18/30 kv PVC power cable, Alu conductor Conductor: Conductor: Insulation: Screen: Insulation: Outher sheath: Outer sheath: stranded plain aluminium conductor Cl.2, acc. to IEC 60228, DIN VDE 0295 XLPE compound red copper wires and one or two copper tape(s) applied helically. red (RAL 3000),PVC compound Applications: Suitable for installation mostly for power supply stations, in indoors and in cable ducts, outdoors, underground, and in water as well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristics, thiscan also be laid easily in difficult line guideways. See DIN VDE 0298 part 1. Nominal voltage: Nominal voltage: Test Testing voltage: voltage: Temperature range: 6/10 kv,12/20 kv,18/30 kv 6/10 kv = V 12/20 kv = V 18/30 kv = V - 5 C +70 C Temperature range: Max. operating temp. on fixed conductor: laying: +90 C flexible application: max. temp on conductor: Resistance: Flame retardant: Flame retardant: acc.to IEC DIN VDE 0482 part /10 kv 18/30 kv 48240QRL010M64 1x35 rm/16 25, QRL010M65 1x50 rm/16 26, QRL010M66 1x70 rm/16 28, / QRL010M67 1x95 rm/16 29, / QRL010M68 1x120 rm/16 31, / QRL010M69 1x150 rm/16* 32, MCM 48240QRL010M69 1x150 rm/25 32, MCM 48241QRL011M70 1x185 rm/16* 34, MCM 48240QRL010M70 1x185 rm/25 34, MCM 48241QRL011M71 1x240 rm/16* 36, MCM 48240QRL010M71 1x240 rm/25 36, MCM 48240QRL010M72 1x300 rm/25 38, MCM 48240QRL010M73 1x400 rm/35 42, MCM 48240QRL010M74 1x500 rm/35 45, MCM 12/20 kv 48240XRL010M65 1x50 rm/16 35, XRL010M66 1x70 rm/16 37, / XRL010M67 1x95 rm/16 38, / XRL010M68 1x120 rm/16 40, / XRL010M69 1x150 rm/25 41, MCM 48240XRL010M70 1x185 rm/25 43, MCM 48240XRL010M71 1x240 rm/25 45, MCM 48240XRL010M72 1x300 rm/25 48, MCM 48240XRL010M73 1x400 rm/35 51, MCM 48240XRL010M74 1x500 rm/35 54, MCM Other dimensions and colours available on request URL010M64 1x35 rm/16 29, URL010M65 1x50 rm/16 30, URL010M66 1x70 rm/16 32, / URL010M67 1x95 rm/16 33, / URL010M68 1x120 rm/16 35, / URL010M69 1x150 rm/16* 36, MCM 48240URL010M69 1x150 rm/25 36, MCM 48241URL011M70 1x185 rm/16* 38, MCM 48240URL010M70 1x185 rm/25 38, MCM 48241URL011M71 1x240 rm/16* 41, MCM 48240URL010M71 1x240 rm/25 41, MCM 48240URL010M72 1x300 rm/25 43, MCM 48240URL010M73 1x400 rm/35 46, MCM 48240URL010M74 1x500 rm/35 49, MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 123

133 MEDIUM VOLTAGE CABLES NA2XS(F)2Y 6/10 kv, 12/20 kv, 18/30 kv Pe-jacket and WATER TIGHT, Alu conductor Conductor: Insulation: Screen: Wrapping: Outer sheath: stranded plain aluminium conductor Cl.2, acc. to IEC 60228, DIN VDE 0295 XLPE,type DIX 8 red copper wires and one or two copper tape(s) applied helically. semi-conductive watertight tape black (RAL 9005),PE,type DMP 2 Nominal voltage: Nominal voltage: Test Testing voltage: voltage: Temperature range: Temperature range: Max. operating temp. 6/10 kv,12/20 kv,18/30 kv 6/10 kv = V 12/20 kv = V 18/30 kv = V - 20 C/+70 Applications: Suitable for indoor installation and in cable ducts,outdoors, underground and in water as well as for installations in cable trays for industries, switchboard sand power station. The PE outer jacket is resistant to high mechanical stress for laying the cables. on fixed conductor: laying: flexible application: Resistance: max. temp on conductor: Flame retardant: +90 C Flame retardant: acc.to IEC DIN VDE 0482 part /10 kv 18/30 kv 48250Q7L010M64 1x35 rm/ Q7L010M65 1x50 rm/ Q7L010M66 1x70 rm/ / Q7L010M67 1x95 rm/ / Q7L010M68 1x120 rm/ / Q7L010M69 1x150 rm/ MCM 48250Q7L010M70 1x185 rm/ MCM 48250Q7L010M71 1x240 rm/ MCM 48250Q7L010M72 1x300 rm/ MCM 48250Q7L010M73 1x400 rm/ MCM 48250Q7L010M74 1x500 rm/ MCM 48250X7L010M65 1x50 rm/ X7L010M66 1x70 rm/ / X7L010M67 1x95 rm/ / X7L010M68 1x120 rm/ / X7L010M69 1x150 rm/ MCM 48250X7L010M70 1x185 rm/ MCM 48250X7L010M71 1x240 rm/ MCM 48250X7L010M72 1x300 rm/ MCM 48250X7L010M73 1x400 rm/ MCM 48250X7L010M74 1x500 rm/ MCM Other dimensions and colours available on request. 12/20 kv 48250U7L010M64 1x35 rm/ U7L010M65 1x50 rm/ U7L010M66 1x70 rm/ / U7L010M67 1x95 rm/ / U7L010M68 1x120 rm/ / U7L010M69 1x150 rm/ MCM 48250U7L010M70 1x185 rm/ MCM 48250U7L010M71 1x240 rm/ MCM 48250U7L010M72 1x300 rm/ MCM 48250U7L010M73 1x400 rm/ MCM 48250U7L010M74 1x500 rm/ MCM * For cables laying in earth a screen-cross section of 16 mm is permitted. 124

134 MEDIUM VOLTAGE CABLES NA2XS(FL)2Y 6/10 kv, 12/20 kv, 18/30 kv Pe-jacket and WATER TIGHT, Alu conductor Conductor: stranded plain aluminium conductor Cl.2, acc. to IEC 60228, DIN VDE 0295 Insulation: XLPE,type DIX 8 Screen: red copper wires and one or two copper tape(s) applied helically. Wrapping: semi-conductive watertight tape Armour: aluminium tape Outer sheath: black (RAL 9005),PE,type DMP 2 Applications: Heavy duty rubber cable are suited as a connecting cable for very high mechanical stress in underground mining and tools for use in industries and outdoor use. They are also Nominal voltage: Test voltage: Temperature range: Max. operating temp. on conductor: Resistance: 6/10 kv,12/20 kv,18/30 kv 6/10 kv = V 12/20 kv = V 18/30 kv = V - 20 C/ C Flame retardant: acc.to IEC DIN VDE 0482 part /10 kv 18/30 kv 48260Q7L010M64 1 X 35 rm / 16 27,0 182,0 780, Q7L010M65 1 X 50 rm / 16 29,0 182,0 850, Q7L010M66 1 X 70 rm / 16 31,0 182,0 980, Q7L010M67 1 X 95 rm / 16 32,0 182,0 1080, Q7L010M68 1 X 120 rm / 16 33,0 182,0 1150, Q7L010M69 1 x 150 rm / 25 35,0 283,0 1280, Q7L010M70 1 x 185 rm / 25 35,0 283,0 1420, Q7L010M71 1 x 240 rm / 25 40,0 283,0 1630, Q7L010M72 1 x 300 rm / 25 41,0 283,0 1950, Q7L010M73 1 x 400 rm / 35 45,0 394,0 2350,0 2/ Q7L010M74 1 x 500 rm / 35 50,0 394,0 2780,0 2/ X7L010M65 1 X 50 rm / 16 38,0 182,0 1251, X7L010M66 1 X 70 rm / 16 39,0 182,0 1505, X7L010M67 1 X 95 rm / 16 41,0 182,0 1705, X7L010M68 1 X 120 rm / 16 43,0 182,0 1800, X7L010M69 1 x 150 rm / 25 44,0 283,0 1285, X7L010M70 1 x 185 rm / 25 45,0 283,0 1425, X7L010M71 1 x 240 rm / 25 47,0 283,0 1635, X7L010M72 1 x 300 rm / 25 48,0 283,0 1955, X7L010M73 1 x 400 rm / 35 49,0 394,0 2352,0 2/ X7L010M74 1 x 500 rm / 35 50,0 394,0 2782,0 2/0 Other dimensions and colours available on request. 12/20 kv 48260U7L010M65 1 X 50 rm / 16 34,0 182,0 920, U7L010M66 1 X 70 rm / 16 35,0 182,0 1030, U7L010M67 1 X 95 rm / 16 35,0 182,0 1140, U7L010M68 1 X 120 rm / 16 36,0 182,0 1250, U7L010M69 1 x 150 rm / 25 40,0 283,0 1320, U7L010M70 1 x 185 rm / 25 40,0 283,0 1570, U7L010M71 1 x 240 rm / 25 45,0 283,0 1780, U7L010M72 1 x 300 rm / 25 45,0 283,0 2100, U7L010M73 1 x 400 rm / 35 49,0 394,0 2480,0 2/ U7L010M74 1 x 500 rm / 35 50,0 394,0 2900,0 2/0 * For cables laying in earth a screen-cross section of 16 mm is permitted. 125

135

136 INSTRUMENTATION CABLES FR2XOHR 300/500 and 450/750 V Conductor: flexible red or tinned copper conductor Cl. 5, acc to IEC Insulation: PVC,type R2 Colour core: blue-black, with black progressively numbered Stranding: cores twisted in pairs in concentric layers Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: black(ral 9005),blue(RAL 5015) or grey (RAL 7001),PVC,type RZ Nominal voltage: Test voltage: up to 0,75 mm 2 : Uo/U 300/500 V from 1 mm 2 : Uo/U 450/750 V 2/2,5 kv Temperature range: -10 C / + 70 C Min. bending radius: 10 x d Resistence: Flame retardant acc. to: I 20-35,IEC low smoke emission: I 20-37,IEC /500 V 450/750 V Cap. max C c C S (pf/m) Inductance L (μh/m) 47010D.X022M05 2x2x0, , D.X032M05 3x2x0,50 7,5 33, , D.X042M05 4x2x0, , , D0.X052M05 5x2x0, , , D0.X062M05 6x2x0, , , D0.X082M05 8x2x0, , , D0.X102M05 10x2x0,50 12,5 100, , D0.X122M05 12x2x0, , D0.X162M05 16x2x0,50 14,5 158, , D0.X202M05 20x2x0,50 16,5 196, , D0.X242M05 24x2x0,50 17,5 234, , D0.X022M07 2x2x0, , , D0.X032M07 3x2x0,75 8, , D0.X042M07 4x2x0,75 9,6 62, , D0.X052M07 5x2x0,75 10,5 76, , D0.X062M07 6x2x0,75 11,5 91, , D0.X082M07 8x2x0,75 12, , D0.X102M07 10x2x0,75 14,5 148, , D0.X122M07 12x2x0, , , D0.X162M07 16x2x0, , , D0.X202M07 20x2x0, , , D0.X242M07 24x2x0,75 20,5 350, ,85 * For cables laying in earth a screen-cross section of 16 mm is permitted. Cap. max C c C S (pf/m) Inductance L (μh/m) 47010E.X022M10 2x2x1 9 43, , E.X032M10 3x2x1 9,5 62, , E.X042M10 4x2x1 10,5 81, , E.X052M10 5x2x1 11,5 100, , E.X062M10 6x2x , E.X082M10 8x2x , , E.X102M10 10x2x1 15,5 196, , E.X122M10 12x2x1 16,5 235, , E.X162M10 16x2x1 18, , E.X202M10 20x2x1 20,5 388, , E.X242M10 24x2x1 22,5 464, , E.X022M15 2x2x1, , , E.X032M15 3x2x1,50 11,5 91, , E.X042M15 4x2x1,50 12, , E.X052M15 5x2x1, , , E.X062M15 6x2x1,50 15,5 177, , E.X082M15 8x2x1,50 16,5 235, , E.X102M15 10x2x1, , , E.X122M15 12x2x1, , , E.X162M15 16x2x1,50 22,5 464, , E.X202M15 20x2x1, , , E.X242M15 24x2x1, ,85 Other dimensions and colours available on request. C : Capacitance core / core maximum, measured at a frequency of 800 khz, between two conductors c C S :Conductor / shield capacitance maximum, measured at a frequency of 800 khz, between conductor and screen *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 127

137 INSTRUMENTATION CABLES FR2XHOHR 300/500 and 450/750 V Conductor: Insulation: Colour core: Stranding: Screen: Individual: Overall: Outer sheath: flexible red or tinned copper conductor Cl. 5, acc to IEC PVC, type R2 PAIR: blue-black, with black progressively numbered. TRIAD: blue-brown-black, with black progressively numbered cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic screen of plastic and aluminium tape + tinned drain-wire electrostatic screen of plastic and aluminium tape + tinned drain-wire black(ral 9005),blue(RAL 5015) or grey (RAL 7001),PVC,type RZ Nominal voltage: Test voltage: up to 0,75 mm 2 : Uo/U 300/500 V from 1 mm 2 : Uo/U 450/750 V 2/2,5 kv Temperature range: -10 C / + 70 C Min. bending radius: 10 x d Resistence: Flame retardant acc. to: I 20-35,IEC low smoke emission: I 20-37,IEC /500 V 450/750 V Cap. max C c C S (pf/m) Inductance L (μh/m) 47020D.X022M05 2x2x0,50 7,5 33, , E.X022M10 2x2x1 9,5 52, , D.X032M05 3x2x0, , E.X032M10 3x2x , , D.X042M05 4x2x0,50 8,5 62, , E.X042M10 4x2x , , D.X052M05 5x2x0,50 9,5 76, , E.X052M10 5x2x1 12,5 124, , D.X062M05 6x2x0,50 10,5 91, , E.X062M10 6x2x1 13,7 148, , D.X082M05 8x2x0,50 11, , E.X082M10 8x2x1 14,5 196, , D.X102M05 10x2x0, , , E.X102M10 10x2x1 16,9 244, , D.X122M05 12x2x0, , , E.X122M10 12x2x1 17,6 292, , D.X162M05 16x2x0,50 15,5 235, , E.X162M10 16x2x , , D.X202M05 20x2x0,50 17,5 292, , E.X202M10 20x2x , , D.X242M05 24x2x0,50 18, , E.X242M10 24x2x , , D.X022M07 2x2x0,75 8,5 43, , E.X022M15 2x2x1,50 11, , D.X032M07 3x2x0,75 9,3 62, , E.X032M15 3x2x1,50 12,5 105, , D.X042M07 4x2x0, , , E.X042M15 4x2x1,50 13,5 139, , D.X052M07 5x2x0,75 11, , E.X052M15 5x2x1, , , D.X062M07 6x2x0,75 12, , E.X062M15 6x2x1,50 16,5 206, , D.X082M07 8x2x0,75 13,5 158, , E.X082M15 8x2x1, , , D.X102M07 10x2x0,75 15,5 196, , E.X102M15 10x2x1,50 20,5 340, , D.X122M07 12x2x0, , , E.X122M15 12x2x1, , D.X162M07 16x2x0,75 18, , E.X162M15 16x2x1, , , D.X202M07 20x2x0, , , E.X202M15 20x2x1,50 26,5 676, , D.X242M07 24x2x0, , , E.X242M15 24x2x1, , ,85 * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. Cap. max C c C S (pf/m) Inductance L (μh/m) C : Capacitance core / core maximum, measured at a frequency of 800 khz, between two conductors c C S :Conductor / shield capacitance maximum, measured at a frequency of 800 khz, between conductor and screen *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 128

138 INSTRUMENTATION CABLES FR2XOHRAR 450/750 V Conductor: flexible red or tinned copper conductor Cl. 5, acc to IEC Insulation: PVC,type R2 Colour core: blue-black, with black progressively numbered Stranding: cores twisted in pairs in concentric layers Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: black(ral 9005),blue(RAL 5015) or grey (RAL 7001),PVC,type RZ Nominal voltage: Test voltage: up to 0,75 mm 2 : Uo/U 300/500 V from 1 mm 2 : Uo/U 450/750 V 2/2,5 kv Temperature range: -10 C / + 70 C Min. bending radius: 10 x d Resistence: Flame retardant acc. to: I 20-35,IEC low smoke emission: I 20-37,IEC /500 V 450/750 V Cap. max C c C S (pf/m) Inductance L (μh/m) 47030D.X022M05 2x2x0,50 9, , E.X022M10 2x2x , , D.X032M05 3x2x0, , , E.X032M10 3x2x , , D.X042M05 4x2x0, , , E.X042M10 4x2x1 13,5 81, , D.X052M05 5x2x0,50 11,5 52, , E.X052M10 5x2x1 14,5 100, , D.X062M05 6x2x0,50 12,5 62, , E.X062M10 6x2x1 15, , D.X082M05 8x2x0,50 13,5 81, , E.X082M10 8x2x1 16,5 158, , D.X102M05 10x2x0, , , E.X102M10 10x2x1 18,5 196, , D.X122M05 12x2x0,50 15, , E.X122M10 12x2x1 19,5 235, , D.X162M05 16x2x0, , , E.X162M10 16x2x , D.X202M05 20x2x0,50 19,5 196, , E.X202M10 20x2x1 22,5 388, , D.X242M05 24x2x0, , , E.X242M10 24x2x , , D.X022M07 2x2x0,75 10,5 33, , E.X022M15 2x2x1,50 13,5 62, , D.X032M07 3x2x0, , E.X032M15 3x2x1, , , D.X042M07 4x2x0,75 12,5 62, , E.X042M15 4x2x1,50 15, , D.X052M07 5x2x0,75 13,5 76, , E.X052M15 5x2x1, , , D.X062M07 6x2x0,75 14,5 91, , E.X062M15 6x2x1,50 18,5 177, , D.X082M07 8x2x0,75 15, , E.X082M15 8x2x1, , , D.X102M07 10x2x0,75 17,5 148, , E.X102M15 10x2x1,50 22,5 292, , D.X122M07 12x2x0, , , E.X122M15 12x2x1, , , D.X162M07 16x2x0,75 20,5 235, , E.X162M15 16x2x1, , , D.X202M07 20x2x0, , , E.X202M15 20x2x1,50 26,5 580, , D.X242M07 24x2x0, , , E.X242M15 24x2x1,50 30, ,85 * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. Cap. max C c C S (pf/m) Inductance L (μh/m) C : Capacitance core / core maximum, measured at a frequency of 800 khz, between two conductors c C S :Conductor / shield capacitance maximum, measured at a frequency of 800 khz, between conductor and screen *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 129

139 INSTRUMENTATION CABLES FR2XHOHRAR 300/500 V Conductor: Insulation: Colour core: Stranding: Screen: Individual: Overall: Armour: Outer sheath: flexible red or tinned copper conductor Cl. 5, acc to IEC PVC, type R2 PAIR: blue-black, with black progressively numbered. TRIAD: blue-brown-black, with black progressively numbered cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic screen of plastic and aluminium tape + tinned drain-wire electrostatic screen of plastic and aluminium tape + tinned drain-wire braid of galvanized steel wires black(ral 9005),blue(RAL 5015) or grey (RAL 7001),PVC,type RZ Nominal voltage: Test voltage: up to 0,75 mm 2 : Uo/U 300/500 V from 1 mm 2 : Uo/U 450/750 V 2/2,5 kv Temperature range: -10 C / + 70 C Min. bending radius: 10 x d Resistence: Flame retardant acc. to: I 20-35,IEC low smoke emission: I 20-37,IEC /500 V 450/750 V Cap. max C c C S (pf/m) Inductance L (μh/m) Cap. max C c C S (pf/m) Inductance L (μh/m) 47040D.X022M05 2x2x0,50 7,5 33, , D.X032M05 3x2x0, , D.X042M05 4x2x0,50 8,5 62, , D.X052M05 5x2x0,50 9,5 76, , D.X062M05 6x2x0,50 10,5 91, , D.X082M05 8x2x0,50 11, , D.X102M05 10x2x0, , , D.X122M05 12x2x0, , , D.X162M05 16x2x0,50 15,5 235, , D.X202M05 20x2x0,50 17,5 292, , D.X242M05 24x2x0,50 18, , D.X022M07 2x2x0,75 8,5 43, , D.X032M07 3x2x0,75 9,5 62, , D.X042M07 4x2x0, , , D.X052M07 5x2x0,75 11, , D.X062M07 6x2x0,75 12, , D.X082M07 8x2x0,75 13,5 158, , D.X102M07 10x2x0,75 15,5 196, , D.X122M07 12x2x0, , , D.X162M07 16x2x0,75 18, , D.X202M07 20x2x0, , , D.X242M07 24x2x0, , ,85 * For cables laying in earth a screen-cross section of 16 mm is permitted E.X022M10 2x2x1 9,5 52, , E.X032M10 3x2x , , E.X042M10 4x2x , , E.X052M10 5x2x1 12,5 124, , E.X062M10 6x2x1 13,5 148, , E.X082M10 8x2x1 14,5 196, , E.X102M10 10x2x , , E.X122M10 12x2x1 17,5 292, , E.X162M10 16x2x , , E.X202M10 20x2x , , E.X242M10 24x2x , , E.X022M15 2x2x1,50 11, , E.X032M15 3x2x1,50 12,5 105, , E.X042M15 4x2x1,50 13,5 139, , E.X052M15 5x2x1, , , E.X062M15 6x2x1,50 16,5 206, , E.X082M15 8x2x1, , , E.X102M15 10x2x1,50 20,5 340, , E.X122M15 12x2x1, , E.X162M15 16x2x1, , , E.X202M15 20x2x1,50 26,5 676, , E.X242M15 24x2x1, , ,85 Other dimensions and colours available on request. C : Capacitance core / core maximum, measured at a frequency of 800 khz, between two conductors c C S :Conductor / shield capacitance maximum, measured at a frequency of 800 khz, between conductor and screen *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 130

140 INSTRUMENTATION CABLES RD-Y(st)Y Conductor: Insulation: Colour core: Stranding: Screen: Outer sheath: stranded tinned copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 PVC compound PAIR 1: blue, red PAIR 2: grey, yellow PAIR 3: green, brown PAIR 4: white, black cores twisted in pairs, 4 pairs stranded to a unit, unit stranded in concentric layers Electrostatic screen of plastic and aluminium tape + tinned drain-wire grey (RAL 7000) or blue (RAL5015) PVC Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistence: 300 V 2/2,5 kv -30 O C / 70 O C - 5 O C / 50 O C +110 O C Flame retardant acc. to: DIN VDE 0482 part /EN / IEC EN EC C low corrosive combustion gas: IEC DIN VDE 0482 part EN Applications: Features: Suitable for-maxi-term-point-connection the pairs are twisted with short pitches and different lay-lenghts wich lead to good cross talk attenuation values in a unit the static screen protects the transmission circuits against outer electrical the material used in manifacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers Conductor resistence: max. 73,6 Ohm/km Insulation resistence: core/core min. 100 MOhm x km core/screen min. 100 MOhm x km Mutual capacitance: at 800 Hz max.100 nf/km (this value may be exceeded by 20% with a make-up to 4 pairs) The data transmission cable RD-Y(St) Y are used in measurament and control technology such as in control rooms of industrial plants and power stations. The cables serves for transmission of analog and digital signals up to frequencies of 10 khmz. These cables offer considerable advantages by using the quick and economial connecting possibilities in Maxi-Termi-point technique. This solderless connecting tecnique is defined by a compression termination that employs a spring-clip for the connection of the cable to a square rigid post without pre-stripping. For this technique it is necessary to have an exact 7 - core stranded conductor and semi-rigid-pvc. Suitable for fixed installation only inside of buildings. with a blue outer sheath is used for intrinsic safe installation. Cross-talk attenuation: at 10 khz and cable lenght of 500 m min. 60 db 47050C.X022M05 2x2x0,5 7,0 29, C.X042M05 4x2x0,5 9,0 49, C.X082M05 8x2x0,5 12,0 89, C.X122M05 12x2x0,5 12,5 129, C.X162M05 16x2x0,5 14,0 169, C.X242M05 24x2x0,5 17,5 249, C.X322M05 32x2x0,5 21,5 329, C.X482M05 48x2x0,5 24,0 489, * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 131

141 INSTRUMENTATION CABLES REXOHR (PE/PVC) Conductor: Insulation: Colour core: Stranding: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC BS 6360 PE compound acc.to BS 6234 blue-black, with black progressively numbered. cores twisted in pairs-triads. pairs-triads twisted in layers electrostatic screen of plastic and aluminium tape + tinned drain-wire blue (RAL 5015) or black (RAL 9005),PVC type TM1 acc. to BS 7655 Nominal voltage: 300/500 V Test voltage: 2 kv Temperature range: Fixed installation: - 30 o C / C Flexible application: C / + 70 o C Max short circuit temperature: o C Resistence: Flame retardant acc. to: BS 4066 IEC Features: according to BS PAIRS: TRIADS: 47060D.X012M05 1x2x0, , D.X022M05 2x2x0, D.X052M05 5x2x0, , D.X102M05 10x2x0, , D.X202M05 20x2x0,50 22,3 196, D.X012M07 1x2x0,75 7,5 19, D.X022M07 2x2x0,75 8,3 33, D.X052M07 5x2x0,75 14,3 76, D.X102M07 10x2x0,75 18,7 148, D.X202M07 20x2x0,75 24, D.X012M10 1x2x1 7, D.X022M10 2x2x1 8,5 43, D.X052M10 5x2x , D.X102M10 10x2x1 18,5 196, D.X202M10 20x2x1 24,5 388, E.X012M15 1x2x1,5 8,3 33, E.X022M15 2x2x1, , E.X052M15 5x2x1,5 16,5 148, E.X102M15 10x2x1,5 21,5 292, E.X202M15 20x2x1,5 28,5 580, D.X013M05 1x3x0,50 7,3 19, D.X013M07 1x3x0,75 7,7 26, D.X013M10 1x3x1 7,7 33, D.X013M15 1x3x1,5 8, Other dimensions and colours available on request. * For cables laying in earth a screen-cross section of 16 mm is permitted. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 132

142 INSTRUMENTATION CABLES REXHOHR (PE/PVC) Conductor: Insulation: Colour core: Stranding: Screen Individual: Overall: stranded red copper conductor Cl. 2, acc to IEC BS 6360 PE compound acc.to BS 6234 blue-black, with black progressively numbered. cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic screen of plastic and aluminium tape + tinned drain-wire electrostatic screen of plastic and aluminium tape + tinned drain-wire Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistence: 300/500 V 2 kv - 30 o C / + 70 o C - 0 o C / + 70 o C 160 o C Flame retardant acc. to: BS 4066 IEC Outer sheath: blue (RAL 5015) or black (RAL 9005),PVC type TM1 acc. to BS 7655 Features: according to BS Possible variation/alternative performance: - PE insulation or elastomeric compound G10 - G7 insulation - Hydrocarbons resistant (ENI 0181) or halogen free thermoplastic compound HF M1 outher sheath - U /U 300/500 0,6/1 kv (with loading of outside diameter) 47070D.X022M05 2x2x0,50 9, D.X042M05 4x2x0,50 11, D.X062M05 6x2x0,50 13, D.X082M05 8x2x0,50 14, D.X102M05 10x2x0,50 17, D.X122M05 12x2x0,50 17, D.X162M05 16x2x0,50 20, D.X202M05 20x2x0,50 22, D.X242M05 24x2x0,50 25, D.X022M07 2x2x0,75 10,4 43, D.X042M07 4x2x0, , D.X062M07 6x2x0, D.X082M07 8x2x0,50 15,5 158, D.X102M07 10x2x0, , D.X122M07 12x2x0,75 16,5 235, D.X162M07 16x2x0,75 21, D.X202M07 20x2x0,75 24,5 388, D.X242M07 24x2x0, , D.X022M10 2x2x1 11,2 52, D.X042M10 4x2x , D.X062M10 6x2x1 15,3 148, D.X082M10 8x2x1 17,3 196, D.X102M10 10x2x1 20,6 244, D.X202M10 20x2x1 26,5 448, D.X022M15 2x2x1, D.X042M15 4x2x1, , D.X062M15 6x2x1,5 19,2 206, D.X082M15 8x2x1, , D.X102M15 10x2x1,5 24,8 340, D.X202M15 20x2x1, , * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 133

143 INSTRUMENTATION CABLES RE-2Y(St)Yv Conductor: Insulation: Colour core: Stranding: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 PE compound PAIR: black, white TRIAD: black, white, red cores twisted in pairs-triads. pairs-triads twisted in layers with a communication core electrostatic screen of plastic and aluminium tape + tinned drain-wire blue (RAL 5015) or black (RAL 9005) PVC type YM1,outer sheath reinforced Features: Reinforced outer sheath the electrostatic screen protect the screened pairs against outer electrostatic interference fields low level of fine attenuation and low mutual capacitance enable long transmission distances and fast pulse acceleration Conductor resistance: 0,5 mm 2 : max. 39,0 0hm/km 0,75 mm 2 : max. 24,6 0hm/km 1,3 mm 2 : max. 14,2 0hm/km Insulation resistance: min. 5 G0hm x km Mutual capacitance: at 800 Hz core/core 0,5 mm 2 : max. 60 nf/km for 1 and 2 pairs: 75 nf/km core/core 0,75 mm 2 : 65 nf/km for 1 and 2 pairs: 110 nf/km core/core 1,3 mm 2 : 75 nf/km for 1 and 2 pairs: 100 nf/km Inductance: max. 0,75 mh/km Nominal voltage: 300/500 V Test voltage: core/core 2 kv core/screen 2 kv Temperature range: - 30 C / + 70 C Max. short circuit temperature: C cross-talk attenuation: min. 0,88 db/km at 60 khz Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN / IEC Applications: Instrumentation cables are used in data processing and process control and are suitable for fixed instalations in damp locations, in open locations, in open spaces and for underground laying. BLACK: BLUE: 47080D7X012M05 1x2x0,5 7,5 15, D7X022M05 2x2x0,5 10,2 30, D7X042M05 4x2x0,5 11,0 50, D7X062M05 6x2x0,5 12,6 70, D7X082M05 8x2x0,5 13,8 90, D7X102M05 10x2x0,5 14,6 110, D7X122M05 12x2x0,5 15,7 130, D7X162M05 16x2x0,5 17,5 170, D7X202M05 20x2x0,5 18,5 210, D7X242M05 24x2x0,5 20,2 270, D7X362M05 36x2x0,5 24,0 370, D7X482M05 48x2x0,5 27,4 490, D7X012M07 1x2x0,75 7,9 20, D7X022M07 2x2x0,75 10,6 35, D7X042M07 4x2x0,75 11,7 65, D7X082M07 8x2x0,75 14,6 125, D7X102M07 10x2x0,75 15,8 154, DBX012M05 1x2x0,5 7,5 15, DBX022M05 2x2x0,5 10,2 30, DBX042M05 4x2x0,5 11,0 50, DBX062M05 6x2x0,5 12,6 70, DBX082M05 8x2x0,5 13,8 90, DBX102M05 10x2x0,5 14,6 110, DBX122M05 12x2x0,5 15,7 130, DBX162M05 16x2x0,5 17,5 170, DBX202M05 20x2x0,5 18,5 210, DBX242M05 24x2x0,5 20,2 270, DBX362M05 36x2x0,5 24,0 370, DBX482M05 48x2x0,5 27,4 490, DBX012M07 1x2x0,75 7,9 20, DBX022M07 2x2x0,75 10,6 35, DBX042M07 4x2x0,75 11,7 65, DBX082M07 8x2x0,75 14,6 125, DBX102M07 10x2x0,75 15,8 154,

144 INSTRUMENTATION CABLES RE-2Y(St)Yv BLACK: BLUE: 47080D7X162M07 16x2x0,75 19,0 245, D7X202M07 20x2x0,75 21,5 298, D7X242M07 24x2x0,75 23,2 365, D7X362M07 36x2x0,75 28,2 532, D7X482M07 48x2x0,75 32,0 708, D7X012M13 1x2x1,3 8,8 31, D7X022M13 2x2x1,3 11,7 62, D7X042M13 4x2x1,3 13,5 114, D7X062M13 6x2x1,3 16,0 168, D7X08M13 8x2x1,3 16,8 218, D7X122M13 12x2x1,3 19,3 322, D7X162M13 16x2x1,3 22,0 426, D7X242M13 24x2x1,3 26,5 684, * For cables laying in earth a screen-cross section of 16 mm is permitted DBX122M07 12x2x0,75 17,0 185, DBX162M07 16x2x0,75 19,0 245, DBX202M07 20x2x0,75 21,5 298, DBX242M07 24x2x0,75 23,2 365, DBX362M07 36x2x0,75 28,2 532, DBX482M07 48x2x0,75 32,0 708, DBX012M13 1x2x1,3 8,8 31, DBX022M13 2x2x1,3 11,7 62, DBX042M13 4x2x1,3 13,5 114, DBX062M13 6x2x1,3 16,0 168, DBX08M13 8x2x1,3 16,8 218, DBX122M13 12x2x1,3 19,3 322, DBX162M13 16x2x1,3 22,0 426, DBX242M13 24x2x1,3 26,5 684, Other dimensions and colours available on request. 135

145 INSTRUMENTATION CABLES RE-2Y(St)Yv-fl Conductor: Insulation: Colour core: Stranding: Screen: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC 6360, DIN VDE 0295 PE compound PAIR: black, white TRIAD: black, white, red cores twisted in pairs-triads. pairs-triads twisted in layers with a communication core electrostatic screen of plastic and aluminium tape + tinned drain-wire blue (RAL 5015) or black (RAL 9005) PVC type YM1,low smoke,low halogen compound Features: the electrostatic screen protect the screened pairs against outer electrostatic interference fields low level of fine attenuation and low mutual capacitance enable long transmission distances and fast pulse acceleration Conductor resistance: 0,5 mm 2 : max. 39,0 0hm/km 0,75 mm 2 : max. 24,6 0hm/km 1,3 mm 2 : max. 14,2 0hm/km Insulation resistance: min. 5 G0hm x km Mutual capacitance: at 800 Hz core/core 0,5 mm 2 : max. 60 nf/km for 1 and 2 pairs: 75 nf/km core/core 0,75 mm 2 : 65 nf/ km for 1 and 2 pairs: 110 nf/km core/core 1,3 mm 2 : 75 nf/km for 1 and 2 pairs: 100 nf/km Inductance: max. 0,75 mh/km cross-talk attenuation: min. 0,88 db/km at 60 khz Nominal voltage: 300/500 V Test voltage: core/core 2 kv core/screen 2 kv Temperature range: - 30 C / + 70 C Max. short circuit temperature: C Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN / IEC Applications: Instrumentation cables are used in data processing and process control and are suitable for fixed instalations in damp locations, in open locations, in open spaces and for underground laying. 136

146 INSTRUMENTATION CABLES RE-2Y(St)Yv-fl BLUE: BLACK: 47090DBX022M05 2x2x0,5 10, DBX042M05 4x2x0,5 11, DBX062M05 6x2x0,5 12, DBX082M05 8x2x0,5 13, DBX102M05 10x2x0,5 14, DBX122M05 12x2x0,5 15, DBX162M05 16x2x0,5 17, DBX202M05 20x2x0,5 18, DBX242M05 24x2x0,5 20, DBX362M05 36x2x0,5 24, DBX482M05 48x2x0,5 27, DBX012M07 1x2x0,75 7, DBX022M07 2x2x0,75 10, DBX042M07 4x2x0,75 11, DBX082M07 8x2x0,75 14, DBX102M07 10x2x0,75 15, DBX122M07 12x2x0,75 17, DBX162M07 16x2x0,75 19, DBX202M07 20x2x0,75 21, DBX242M07 24x2x0,75 23, DBX362M07 36x2x0,75 28, DBX482M07 48x2x0,75 32, DBX012M13 1x2x1,3 8, DBX022M13 2x2x1,3 11, DBX042M13 4x2x1,3 13, DBX062M13 6x2x1,3 16, DBX08M13 8x2x1,3 16, DBX122M13 12x2x1,3 19, DBX162M13 16x2x1,3 22, DBX242M13 24x2x1,3 26, Other dimensions and colours available on request D7X012M05 1x2x0,5 7, D7X022M05 2x2x0,5 10, D7X042M05 4x2x0,5 11, D7X062M05 6x2x0,5 12, D7X082M05 8x2x0,5 13, D7X102M05 10x2x0,5 14, D7X122M05 12x2x0,5 15, D7X162M05 16x2x0,5 17, D7X202M05 20x2x0,5 18, D7X242M05 24x2x0,5 20, D7X362M05 36x2x0,5 24, D7X482M05 48x2x0,5 27, D7X012M07 1x2x0,75 7, D7X022M07 2x2x0,75 10, D7X042M07 4x2x0,75 11, D7X082M07 8x2x0,75 14, D7X102M07 10x2x0,75 15, D7X122M07 12x2x0,75 17, D7X162M07 16x2x0,75 19, D7X202M07 20x2x0,75 21, D7X242M07 24x2x0,75 23, D7X362M07 36x2x0,75 28, D7X482M07 48x2x0,75 32, D7X012M13 1x2x1,3 8, D7X022M13 2x2x1,3 11, D7X042M13 4x2x1,3 13, D7X062M13 6x2x1,3 16, D7X08M13 8x2x1,3 16, D7X122M13 12x2x1,3 19, D7X162M13 16x2x1,3 22, * For cables laying in earth a screen-cross section of 16 mm is permitted. 137

147 INSTRUMENTATION CABLES RE-2Y(St)Y PiMF Screened multi pair, PE insulated, PVC sheath Conductor: Insulation: Colour core: Stranding: Screen Individual: Overall: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 PE type 2YI1 white-black, with black progressively numbered. cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic screen of plastic and aluminium tape + tinned drain-wire electrostatic screen of plastic and aluminium tape + tinned drain-wire Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistence: 300/500 V 2 kv - 30 o C / + 70 o C 0 o C / + 70 o C 160 o C Flame retardant acc. to: DIN VDE 0482 part / IEC Outer sheath: blue (RAL 5015) or black (RAL 9005),PVC type TM1 Applications: Features: standard TS/DIN EN Insulation thickness: mm 2 0,50 0, ,3 1,5 mm 0,40 0,40 0,40 0,45 0,45 Conductor resistance: mm 2 0,50 0, ,3 1,5 Ω/km 36,7 25,0 18,5 14,2 12,3 Insulation resistance: min MΩ.km Mutual capacitance: 4 pairs all other pairs 0,50 mm 2 : max. 115 pf/m max. 90 pf/m 0,75 mm 2 : max. 115 pf/m max. 90 pf/m 1,0 mm 2 : max. 115 pf/m max. 90 pf/m 1,3 mm 2 : max. 120 pf/m max. 105 pf/m 1,5 mm 2 : max. 120 pf/m max. 105 pf/m Capacitance unbalance: (1 khz): max. 500 pf/500 m L/R (oran-ratio) (max.): mm 2 0,50 0, ,3 1,5 µh/ω These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation,in dry and wet locations,on rack trays, in conduits. 138

148 INSTRUMENTATION CABLES RE-2Y(St)Y PiMF Screened multi pair, PE insulated, PVC sheath 47100D.X022M05 2x2x0,50 9, D.X042M05 4x2x0,50 11, D.X062M05 6x2x0,50 13, D.X082M05 8x2x0,50 14, D.X102M05 10x2x0,50 17, D.X122M05 12x2x0,50 17, D.X162M05 16x2x0,50 20, D.X202M05 20x2x0,50 22, D.X242M05 24x2x0,50 25, D.X022M07 2x2x0,75 10,4 43, D.X042M07 4x2x0, , D.X062M07 6x2x0, D.X082M07 8x2x0,50 15,5 158, D.X102M07 10x2x0, , D.X122M07 12x2x0,75 16,5 235, D.X162M07 16x2x0,75 21, D.X202M07 20x2x0,75 24,5 388, D.X242M07 24x2x0, , D.X022M10 2x2x1 11,2 52, D.X042M10 4x2x , D.X062M10 6x2x1 15,3 148, D.X082M10 8x2x1 17,3 196, D.X102M10 10x2x1 20,6 244, D.X202M10 20x2x1 26,5 448, D.X022M15 2x2x1, D.X042M15 4x2x1, , D.X062M15 6x2x1,5 19,2 206, D.X082M15 8x2x1, , D.X102M15 10x2x1,5 24,8 340, D.X202M15 20x2x1, , * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 139

149 INSTRUMENTATION CABLES RE-2Y(St)Yv PiMF Conductor: Insulation: Colour core: Stranding: Screen: Individual: Overall: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 PE compound core cores with numbering 1st core : black 2nd core : white with number print 1/1, 2/2 etc. cores twisted in pairs, PiMF (pair in metal foil), foil taping, drain-wire, Cu-bare 0,6 mm,plastic coated alu-foil and plastic foil, PiMF stranded in layer, 1 communication core PE-insulation orange electrostatic screen of plastic and aluminium tape + tinned drain-wire electrostatic screen of plastic and aluminium tape + tinned drain-wire blue (RAL 5015) or black (RAL 9005) PVC compound,low smoke and low halogen compound Features: Conductor resistence: Insulation resistence: 0,5 mm : max. 0,39 0hm/km 1,3 mm : max. 14,2 0hm/km min. 5 G0hm x km Nominal voltage: Test voltage: core/core: core /screen: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistance: 300 V 2 kv 2 kv - 40 o C / + 70 o C - 5 o C / + 70 o C +160 o C Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC Applications: Instrumentation cables are used in data processing and process control. in damp locations, in open space and in underground laying. Mutual capacitance: Inductance: Cross-talk: at 800 Hz core/core 0,5 mm : 75 nf/km core/core 1,3 mm : 100 nf/km max. 0,75 mh/km min 1,02 db/kmat 60 khz BLACK: BLUE: 47110C7X022M05 2x2x0,5 12, C7X042M05 4x2x0,5 12, C7X062M05 6x2x0,5 14, C7X082M05 8x2x0,5 14, C7X102M05 10x2x0,5 16, C7X122M05 12x2x0,5 17, C7X162M05 16x2x0,5 19, C7X202M05 20x2x0,5 21, C7X242M05 24x2x0,5 23, C7X362M05 36x2x0,5 26, C7X482M05 48x2x0,5 32, C7X022M13 2x2x1,3 12, C7X042M13 4x2x1,3 15, C7X062M13 6x2x1,3 16, C7X082M13 8x2x1,3 18, C7X122M13 12x2x1,3 21, C7X162M13 16x2x1,3 24, C7X242M13 24x2x1,3 29, CBX022M05 2x2x0,5 12, CBX042M05 4x2x0,5 12, CBX062M05 6x2x0,5 14, CBX082M05 8x2x0,5 14, CBX102M05 10x2x0,5 16, CBX122M05 12x2x0,5 17, CBX162M05 16x2x0,5 19, CBX202M05 20x2x0,5 21, CBX242M05 24x2x0,5 23, CBX362M05 36x2x0,5 26, CBX482M05 48x2x0,5 32, CBX022M13 2x2x1,3 12, CBX042M13 4x2x1,3 15, CBX062M13 6x2x1,3 16, CBX082M13 8x2x1,3 18, CBX122M13 12x2x1,3 21, CBX162M13 16x2x1,3 24, CBX242M13 24x2x1,3 29, * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. 140

150 INSTRUMENTATION CABLES RE-2Y(St)YRY Screened/armouring single and multi pair, PE insulated, PVC sheath Conductor: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 Insulation: PE type 2YI1 Colour core: black/white, cores numbered Stranding: two conductors twisted to pair Wrapping: Polyester tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Armour: braid of galvanized steel wires Inner sheath: PVC type YM1, Outer sheath: black (RAL 9005), or blue (RAL 5015) PVC type YM1 Features: standard TS/DIN EN Min. bending radius: 10 x d Insulation thickness: mm 2 0,50 0, ,3 1,5 mm 0,40 0,40 0,40 0,45 0,45 Conductor resistance: mm 2 0,50 0, ,3 1,5 Ω/km 36,7 25,0 18,5 14,2 12,3 Insulation resistance: min MΩ.km Mutual capacitance: 4 pairs all other pairs 0,50 mm 2 : max. 115 pf/m max. 90 pf/m 0,75 mm 2 : max. 115 pf/m max. 90 pf/m 1,0 mm 2 : max. 115 pf/m max. 90 pf/m 1,3 mm 2 : max. 120 pf/m max. 105 pf/m 1,5 mm 2 : max. 120 pf/m max. 105 pf/m Capacitance unbalance: (1 khz): max. 500 pf/500 m L/R (oran-ratio) (max.): mm 2 0,50 0, ,3 1,5 µh/ω Nominal voltage: 300/500 V Test voltage: 1,5 kv Temperature range: Fixed installation: - 30 C / + 70 C Flexible application: - 5 C / + 50 C Min. bending radius: 7,5 x d Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC Applications: These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation, in dry and wet locations, on rack trays, in conduits. 141

151 INSTRUMENTATION CABLES RE-2Y(St)YRY Screened/armouring single and multi pair, PE insulated, PVC sheath 47120D.X022M05 2x2x0,50 12, D.X042M05 4x2x0,50 13, D.X082M05 8x2x0, D.X122M05 12x2x0,50 20, D.X162M05 16x2x0, D.X242M05 24x2x0,50 27, D.X022M07 2x2x0, D.X042M07 4x2x0,75 14, D.X082M07 8x2x0,75 19, D.X122M07 12x2x0, D.X162M07 16x2x0,75 25, D.X242M07 24x2x0,75 30, D.X022M10 2x2x1 13,5 43, D.X042M10 4x2x1 16,5 81, D.X082M10 8x2x , D.X122M10 12x2x1 25,5 235, D.X162M10 16x2x1 27, D.X242M10 24x2x , D.X022M15 2x2x1,5 16,5 62, D.X042M15 4x2x1,5 19, D.X082M15 8x2x1,5 21,5 235, D.X122M15 12x2x1,5 28,7 350, D.X162M15 16x2x1,5 32,1 464, D.X242M15 24x2x1,5 41, * For cables laying in earth a screen-cross section of 16 mm is permitted. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors Other dimensions and colours available on request. 142

152 INSTRUMENTATION CABLES RE-2Y(St)YRY Screened/armouring multi core, PE insulated, PVC sheath Conductor: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 Insulation: PE type 2YI1 Colour core: black cores numbered Stranding: PiMF laid up in layers of optimum pitch Wrapping: Polyester tape over solid tinned copper drain wire, 0,60 mm Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Armour: braid of galvanized steel wires Inner sheath: PVC type YM1 Outer sheath: black (RAL 9005), or blue (RAL 5015) PVC type YM1 Features: standard TS/DIN EN Mutual capacitance: max. 120 pf/m Conductor resistance: mm 2 0,50 0,75 1,0 1,3 1,5 2,5 Ω/km 36,7 24,5 18,1 13,9 12,1 7,4 Insulation resistance: min MΩ.km L/R (oran-ratio) (max.): mm 2 0,50 0, ,3 1,5 2,5 µh/ω Nominal voltage: 300/500 V Test voltage: 1,5 kv Temperature range: Fixed installation: - 30 C / + 70 C Flexible application: - 5 C / + 50 C Min. bending radius: 7,5 x d Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC Applications: These cables are used for control purposes, (controlling of pumps valves or engines) at chemistry and petrochemistry industry plants, power plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. These cables are for indoor/outdoor installation, in dry and wet locations, on rack, trays, in conduits D.1020M05 2x0,50 10,8 14, D.1030M05 3x0,50 11,3 19, D.1040M05 4x0,50 11,8 24, D.1050M05 5x0,50 12,4 29, D.1060M05 6x0,50 13,0 34, D.1080M05 8x0,50 13,9 43, D.1100M05 10x0,50 15,2 53, D.1120M05 12x0,50 15,5 62, D.1140M05 14x0,50 16,0 72, D.1160M05 16x0,50 16,6 82, D.1200M05 20x0,50 17,9 101, D.1240M05 24x0,50 19,4 120, D.1270M05 27x0,50 19,7 134, D.1300M05 30x0,50 20,9 149, D.1370M05 37x0,50 22,1 182, D.1400M05 40x0,50 23,0 197, D.1020M07 2x0,75 11,4 19, D.1030M07 3x0,75 11,8 26, D.1040M07 4x0,75 12,3 34, D.1050M07 5x0,75 12,9 41, D.1020M13 2x1,3 12,3 30, D.1030M13 3x1,3 12,7 42, D.1030M13 4x1,3 13,4 55, D.1050M13 5x1,3 14,2 67, D.1060M13 6x1,3 15,2 80, D.1080M13 8x1,3 16,3 105, D.1100M13 10x1,3 17,8 130, D.1120M13 12x1,3 18,2 155, D.1140M13 14x1,3 19,1 180, D.1160M13 16x1,3 20,6 204, D.1200M13 20x1,3 22,2 254, D.1240M13 24x1,3 24,2 304, D.1270M13 27x1,3 24,6 342, D.1300M13 30x1,3 25,3 379, D.1370M13 37x1,3 27,1 467, D.1400M13 40x1,3 27,9 504, D.1020M15 2x1,5 12,6 34, D.1030M15 3x1,5 13,0 48, D.1030M15 4x1,5 13,8 62, D.1050M15 5x1,5 14,6 77, Other dimensions and colours available on request. 143

153 INSTRUMENTATION CABLES RE-2Y(St)YRY Screened/armouring multi core, PE insulated, PVC sheath 47120D.1060M07 6x0,75 13,4 48, D.1080M07 8x0,75 14,8 62, D.1100M07 10x0,75 16,0 77, D.1120M07 12x0,75 16,4 91, D.1140M07 14x0,75 16,9 106, D.1160M07 16x0,75 17,5 120, D.1060M07 20x0,75 19,1 149, D.1240M07 24x0,75 21,3 178, D.1270M07 27x0,75 21,6 199, D.1300M07 30x0,75 22,2 221, D.1370M07 37x0,75 23,7 271, D.1400M07 40x0,75 24,4 293, D.1020M10 2x1 11,8 24, D.1030M10 3x1 12,2 34, D.1040M10 4x1 12,8 43, D.1050M10 5x1 13,5 53, D.1060M10 6x1 14,2 62, D.1080M10 8x1 15,5 82, D.1100M10 10x1 16,8 101, D.1120M10 12x1 17,2 120, D.1140M10 14x1 17,8 139, D.1160M10 16x1 18,5 158, D.1200M10 20x1 20,9 197, D.1240M10 24x1 22,7 235, D.1270M10 27x1 23,1 264, D.1300M10 30x1 23,7 293, D.1370M10 37x1 25,1 360, D.1400M10 40x1 26,1 388, * For cables laying in earth a screen-cross section of 16 mm is permitted D.1060M15 6x1,5 15,6 91, D.1080M15 8x1,5 16,9 120, D.1100M15 10x1,5 18,4 149, D.1120M15 12x1,5 19,0 178, D.1130M15 14x1,5 19,7 206, D.1160M15 16x1,5 21,3 235, D.1200M15 20x1,5 23,2 293, D.1240M15 24x1,5 25,1 350, D.1270M15 27x1,5 25,5 394, D.1300M15 30x1,5 26,4 437, D.1370M15 37x1,5 28,1 538, D.1400M15 40x1,5 29,0 581, D.1020M25 2x2,5 13,8 34, D.1030M25 3x2,5 14,3 48, D.1040M25 4x2,5 15,4 62, D.1050M25 5x2,5 16,4 77, D.1060M25 6x2,5 17,4 91, D.1080M25 8x2,5 19,1 120, D.1100M25 10x2,5 21,7 149, D.1120M25 12x2,5 22,2 178, D.1140M25 14x2,5 23,3 206, D.1160M25 16x2,5 24,3 235, D.1200M25 20x2,5 26,4 293, D.1240M25 24x2,5 28,9 350, D.1270M25 27x2,5 29,4 394, D.1300M25 30x2,5 30,5 437, D.1370M25 37x2,5 33,2 538, D.1400M25 40x2,5 34,9 581, Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 144

154 INSTRUMENTATION CABLES RE-2Y(St)YRY PiMF Screened/armouring multi pair, PE insulated, PVC sheath Conductor: stranded red copper conductor Cl. 2, acc to IEC 60228, DIN VDE 0295 Insulation: PE type 2YI1 Colour core: black/white, cores numbered Stranding: two conductors twisted to pair, PiMF laid up in layers of optimum pitch Wrapping: (PiMF) Polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm Screen: Individual: Overall: Armour: Inner sheath: Outer sheath: electrostatic, made up of an aluminium tape/polymer + drain-wire tinned electrostatic, made up of an aluminium tape/polymer + drain-wire tinned braid of galvanized steel wires PVC compound black (RAL 9005), or blue (RAL 5015) PVC type YM1 Nominal voltage: 300/500 V Test voltage: 2 kv Temperature range: Fixed installation: - 30 C / + 90 C Flexible application: - 5 C / + 50 C Min. bending radius: 10 x d Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC Applications: These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation, in dry and wet locations, on rack trays, in conduits.. Features: standard TS/DIN EN Mutual capacitance: max. 120 pf/m Insulation thickness: mm 2 0,50 0, ,3 1,5 mm 0,40 0,40 0,40 0,45 0,45 Conductor resistance: mm 2 0,50 0, ,3 1,5 Ω/km 36,7 25,0 18,5 14,2 12,3 Insulation resistance: min MΩ.km Capacitance unbalance: (1 khz): max. 500 pf/500 m L/R (oran-ratio) (max.): mm 2 0,50 0, ,3 1,5 µh/ω

155 INSTRUMENTATION CABLES RE-2Y(St)YRY PiMF Screened/armouring multi pair, PE insulated, PVC sheath 47130D.X022M05 2x2x0,50 13,1 33, D.X042M05 4x2x0,50 15,3 57, D.X082M05 8x2x0,50 20, D.X122M05 12x2x0,50 23, D.X162M05 16x2x0,50 26, D.X242M05 24x2x0,50 31, D.X022M07 2x2x0,75 13,8 43, D.X042M07 4x2x0,75 16,6 81, D.X082M07 8x2x0,75 21,1 158, D.X122M07 12x2x0,75 25,8 230, D.X162M07 16x2x0,75 27, D.X242M07 24x2x0,75 36,0 465, D.X022M10 2x2x1 15,3 52, D.X042M10 4x2x , D.X082M10 8x2x , D.X122M10 12x2x1 27,4 292, D.X162M10 16x2x1 30,3 388, D.X242M10 24x2x1 38,8 580, D.X022M15 2x2x1, D.X042M15 4x2x1,5 20,8 134, D.X082M15 8x2x1,5 27,2 273, D.X122M15 12x2x1,5 32, D.X162M15 16x2x1,5 37,3 527, D.X242M15 24x2x1,5 45,5 763, * For cables laying in earth a screen-cross section of 16 mm is permitted. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors Other dimensions and colours available on request. 146

156 INSTRUMENTATION CABLES RE-2Y(St)YSWAY Screened/armouring single and multi pair,pe insulated, PVC sheath Conductor: stranded red copper conductor Cl. 2, acc to IEC 60228,DIN VDE 0295 Insulation: PE compound Colour core: black/white,cores numbered Stranding: two conductors twisted to pair Wrapping: Polyester tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Inner sheath: PVC compound Armour: braid of galvanized steel wires Outer sheath: black (RAL 9005), or blue (RAL 5015) PVC compound Features: standard TS/DIN EN Insulation thickness: mm 2 0,50 0, ,3 1,5 mm 0,40 0,40 0,40 0,45 0,45 Conductor resistance: mm 2 0,50 0, ,3 1,5 Ω/km 36,7 25,0 18,5 14,2 12,3 Insulation resistance: min MΩ.km Mutual capacitance: 4 pairs all other pairs 0,50 mm 2 : max. 115 pf/m max. 90 pf/m 0,75 mm 2 : max. 115 pf/m max. 90 pf/m 1,0 mm 2 : max. 115 pf/m max. 90 pf/m 1,3 mm 2 : max. 120 pf/m max. 105 pf/m 1,5 mm 2 : max. 120 pf/m max. 105 pf/m Capacitance unbalance: (1 khz): max. 500 pf/500 m L/R (ratio) (max.): mm 2 0,50 0, ,3 1,5 µh/ω Nominal voltage: 300 V Test voltage: 1,5 kv Temperature range: Fixed installation: - 30 C / 70 C Flexible application: - 5 C /+ 50 C Min. bending radius: 10 x d Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC C Applications: These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation, in dry and wet locations, on rack trays, in conduits C.X012M05 1x2x0,50 10,2 14, C.X022M05 2x2x0,50 12,7 24, C.X042M05 4x2x0,50 14,0 43, C.X052M05 5x2x0,50 14,5 53, C.X062M05 6x2x0,50 15,4 62, C.X082M05 8x2x0,50 16,6 82, C.X102M05 10x2x0,50 17,7 101, C.X122M05 12x2x0,50 18,7 120, C.X162M05 16x2x0,50 21,4 158, C.X202M05 20x2x0,50 23,2 197, C.X242M05 24x2x0,50 24,6 235, C.X012M07 1x2x0,75 10,6 19, C.X022M07 2x2x0,75 13,4 34, C.X042M07 4x2x0,75 14,8 62, C.X072M07 5x2x0,75 15,5 77, C.X062M07 6x2x0,75 16,3 91, C.X082M07 8x2x0,75 17,7 120, C.X042M10 4x2x1 15,9 82, C.X052M10 5x2x1 16,4 101, C.X062M10 6x2x1 17,3 120, C.X082M10 8x2x1 18,8 158, C.X102M10 10x2x1 21,1 197, C.X122M10 12x2x1 22,4 235, C.X162M10 16x2x1 24,8 312, C.X202M10 20x2x1 26,9 389, C.X242M10 24x2x1 28,7 466, C.X012M13 1x2x1.3 11,8 30, C.X022M13 2x2x1.3 15,1 55, C.X042M13 4x2x1.3 17,1 105, C.X052M13 5x2x1.3 17,7 130, C.X062M13 6x2x1.3 18,7 155, C.X082M13 8x2x1.3 21,4 204, C.X102M13 10x2x1.3 23,0 254, C.X122M13 12x2x1.3 24,6 304,

157 INSTRUMENTATION CABLES RE-2Y(St)YSWAY Screened/armouring single and multi pair,pe insulated, PVC sheath 47140C.X102M07 10x2x0,75 19,0 149, C.X122M07 12x2x0,75 21,0 178, C.X162M07 16x2x0,75 23,2 235, C.X202M07 20x2x0,75 25,0 293, C.X242M07 24x2x0,75 26,7 350, C.X012M10 1x2x1 11,0 24, C.X022M10 2x2x1 14,1 43, C.X082M10 8x2x1 16,7 197, * For cables laying in earth a screen-cross section of 16 mm is permitted. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 47140C.X162M13 16x2x1,3 27,3 404, C.X202M13 20x2x1,3 29,5 504, C.X242M13 24x2x1,3 32,8 604, C.X012M15 1x2x1,5 12,0 34, C.X022M15 2x2x1,5 15,6 62, C.X042M15 4x2x1,5 17,5 120, C.X052M15 5x2x1,5 18,2 149, C.X062M15 6x2x1,5 20,1 178, C.X082M15 8x2x1,5 22,0 235, C.X102M15 10x2x1,5 23,8 293, C.X122M15 12x2x1,5 25,3 350, C.X162M15 16x2x1,5 28,1 466, C.X202M15 20x2x1,5 30,6 581, C.X242M15 24x2x1,5 33,8 696, Other dimensions and colours available on request. 148

158 INSTRUMENTATION CABLES RE-2X(St)Y Fl Screened single and multi pair, XLPE insulated, PVC sheath Conductor: stranded red copper conductor Cl. 2, acc to IEC 60228,DIN VDE 0295 Insulation: XLPE compound Colour core: black/white,cores numbered Stranding: two conductors twisted to pair Wrapping: Polyester tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: black (RAL 9005), or blue (RAL 5015) PVC compound Features: Insulation thickness: mm 2 0,50 0, ,3 1,5 mm 0,40 0,40 0,40 0,45 0,45 Conductor resistance: mm 2 0,50 0, ,3 1,5 Ω/km 36,7 25,0 18,5 14,2 12,3 Insulation resistance: min MΩ.km Mutual capacitance: max. 120 pf/m Capacitance unbalance: (1 khz): max. 500 pf/500 m L/R (oran-ratio) (max.): mm 2 0,50 0, ,3 1,5 µh/ω Nominal voltage: 300 V Test voltage: 1,5 kv Temperature range: Fixed installation: - 30 C / + 70 C Flexible application: - 5 C / + 50 C Min. bending radius: 7,5 x d Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN / IEC Applications: These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation, in dry and wet locations, on rack trays, in conduits C.X012M05 1x2x0,50 6, C.X022M05 2x2x0,50 8, C.X042M05 4x2x0, C.X082M05 8x2x0,50 11, C.X122M05 12x2x0,50 13, C.X162M05 16x2x0,50 15, C.X242M05 24x2x0,50 18, C.X012M07 1x2x0,75 6, C.X022M07 2x2x0,75 9, C.X042M07 4x2x0, C.X082M07 8x2x0,75 12, C.X122M07 12x2x0,75 15, C.X162M07 16x2x0,75 17, C.X242M07 24x2x0, * For cables laying in earth a screen-cross section of 16 mm is permitted C.X012M10 1x2x1 7, C.X022M10 2x2x C.X042M10 4x2x C.X082M10 8x2x1 14, C.X122M10 12x2x C.X162M10 16x2x1 19, C.X242M10 24x2x1 23, C.X012M13 1x2x1,3 7, C.X022M13 2x2x1, C.X042M13 4x2x1,3 12, C.X082M13 8x2x1,3 15, C.X122M13 12x2x1,3 19, C.X162M13 16x2x1,3 21, C.X242M13 24x2x1,3 26, Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 149

159 INSTRUMENTATION CABLES RE-2X(St)Yv PiMF Conductor: Insulation: stranded red copper conductor Cl. 2, acc to IEC 60228,DIN VDE 0295 XLPE compound Nominal voltage: Test voltage: 300 V 1,5 kv Colour core: Stranding: Screen: Individual: Overall: Outer sheath: blue,black with progressively numbered pairs stranded to layers, multi-pair versions with communication core (XLPE-orange) electrostatic, made up of an aluminium tape/polymer + drain-wire tinned electrostatic, made up of an aluminium tape/polymer + drain-wire tinned black (RAL 9005), or blue (RAL 5015) PVC compound Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Inductance: Resistance: - 30 o C / + 70 o C - 5 o C / + 50 o C +160 o C max. 0,65 mh/km Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC Features: Reinforced outer sheath more steady at higher frequences and temperature by XLPE core insulation (cross-linked PE) three-coat shield high cross-talk and low cable attenuation largely resistant to acids, bases and usual oils robust version (generally with strengthened black or blue outer sheath) IEC 189and IEC 502, HD 34, KEMA k102 and draft NELEC specifications for computer cables Conductor resistence: 0,5 : max. 39,2 Ohm/km 0,75 : max. 24,6 Ohm/km 1,3 : 14,2 Ohm /km Insulation resistence: min. 5 G0hm x km Applications: computer cable for optimal data transmission at medium data transfer rates up to 200 kbits/s in process control and IT-systems for lossless data and signal transmission. Suitable for dry and humid rooms, outdoor use and laying underground. BLACK: BLUE: 47160C7X022M05 2x2x0,5 10, C7X042M05 4x2x0,5 12, C7X122M05 12x2x0,5 17, C7X242M05 24x2x0, C7X022M07 2x2x0,75 11, C7X042M07 4x2x0, C7X062M07 6x2x0,75 15, C7X082M07 8x2x0,75 16, C7X122M07 12x2x0,75 18, C7X242M07 24x2x0,75 25, C7X022M07 2x2x1,3 12, C7X042M07 4x2x1,3 14, C7X062M07 6x2x1, C7X082M07 8x2x1, C7X122M07 12x2x1,3 21, C7X242M07 24x2x1, * For cables laying in earth a screen-cross section of 16 mm is permitted CBX022M05 2x2x0,5 10, CBX042M05 4x2x0,5 12, CBX062M05 6x2x0,5 14, CBX122M05 12x2x0,5 17, CBX242M05 24x2x0, CBX022M07 2x2x0,75 11, CBX042M07 4x2x0, CBX062M07 6x2x0,75 15, CBX082M07 8x2x0,75 16, CBX122M07 12x2x0,75 18, CBX242M07 24x2x0,75 25, CBX022M13 2x2x1,3 12, CBX042M13 4x2x1,3 14, CBX062M13 6x2x1, CBX082M13 8x2x1, CBX122M13 12x2x1,3 21, CBX242M13 24x2x1, Other dimensions and colours available on request. 150

160 INSTRUMENTATION CABLES RE-2X(St)YSWAY Screened/armouring single and multi pair, XLPE insulated, PVC sheath Conductor: Insulation: Colour core: Stranding: Wrapping: Screen: Inner sheath: Armour: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC 60228,DIN VDE 0295 XLPE compound blue,black with progressively numbered two conductors twisted to pair, pair laid up in layers with optimum pitch Polyester tape electrostatic, made up of an aluminium tape/polymer + drain-wire tinned PVC compound braid of galvanized steel wires black (RAL 9005), or blue (RAL 5015) PVC compound Features: standard TS/DIN EN Insulation thickness: mm 2 0,50 0, ,3 1,5 mm 0,40 0,40 0,40 0,45 0,45 Conductor resistance: mm 2 0,50 0, ,3 1,5 Ω/km 36,7 25,0 18,5 14,2 12,3 Insulation resistance: min MΩ.km Mutual capacitance: 4 pairs all other pairs 0,50 mm 2 : max. 115 pf/m max. 90 pf/m 0,75 mm 2 : max. 115 pf/m max. 90 pf/m 1,0 mm 2 : max. 115 pf/m max. 90 pf/m 1,3 mm 2 : max. 120 pf/m max. 105 pf/m 1,5 mm 2 : max. 120 pf/m max. 105 pf/m Capacitance unbalance: (1 khz): max. 500 pf/500 m L/R (ratio) (max.): mm 2 0,50 0, ,3 1,5 µh/ω Nominal voltage: Uo/U 300/500 V Test voltage: 2 kv Temperature range: Fixed installation: - 30 C / 90 C Flexible application: - 5 C /+ 50 C Min. bending radius: 10 x d Resistance: Flame retardant acc. to: DIN VDE 0482 part /EN /IEC Applications: These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation, in dry and wet locations, on rack trays, in conduits D.X012M05 1x2x0,50 10,2 14, D.X022M05 2x2x0,50 12,7 24, D.X042M05 4x2x0,50 14,0 43, D.X052M05 5x2x0,50 14,5 53, D.X062M05 6x2x0,50 15,4 62, D.X082M05 8x2x0,50 16,6 82, D.X102M05 10x2x0,50 17,7 101, D.X122M05 12x2x0,50 18,7 120, D.X162M05 16x2x0,50 21,4 158, D.X202M05 20x2x0,50 23,2 197, D.X242M05 24x2x0,50 24,6 235, DBX012M07 1x2x0,75 10,6 19, D.X022M07 2x2x0,75 13,4 34, D.X042M07 4x2x0,75 14,8 62, D.X052M07 5x2x0,75 15,5 77, D.X062M07 6x2x0,75 16,3 91, D.X082M07 8x2x0,75 17,7 120, D.X042M10 4x2x1 15,9 82, D.X102M10 5x2x1 16,4 101, D.X062M10 6x2x1 17,3 120, D.X082M10 8x2x1 18,8 158, D.X102M10 10x2x1 21,1 197, D.X122M10 12x2x1 22,4 235, D.X162M10 16x2x1 24,8 312, D.X202M10 20x2x1 26,9 389, D.X242M10 24x2x1 28,7 466, D.X012M13 1x2x1.3 11,8 30, D.X022M13 2x2x1.3 15,1 55, D.X042M13 4x2x1.3 17,1 105, D.X052M13 5x2x1.3 17,7 130, D.X062M13 6x2x1.3 18,7 155, D.X082M13 8x2x1.3 21,4 204, D.X102M13 10x2x1.3 23,0 254, D.X122M13 12x2x1.3 24,6 304, * For cables laying in earth a screen-cross section of 16 mm is permitted. Other dimensions and colours available on request. 151

161 INSTRUMENTATION CABLES RE-2X(St)YSWAY Screened/armouring single and multi pair, XLPE insulated, PVC sheath 47170D.X102M07 10x2x0,75 19,0 149, D.X122M07 12x2x0,75 21,0 178, D.X162M07 16x2x0,75 23,2 235, D.X202M07 20x2x0,75 25,0 293, D.X242M07 24x2x0,75 26,7 350, D.X012M10 1x2x1 11,0 24, D.X022M10 2x2x1 14,1 43, * For cables laying in earth a screen-cross section of 16 mm is permitted. *the point of the code in the location of the coloring of the. outer sheath gives tells us that this can be of different colors 47170D.X162M13 16x2x1,3 27,3 404, D.X202M13 20x2x1,3 29,5 504, D.X242M13 24x2x1,3 32,8 604, D.X012M15 1x2x1,5 12,0 34, D.X022M15 2x2x1,5 15,6 62, D.X042M15 4x2x1,5 17,5 120, D.X052M15 5x2x1,5 18,2 149, D.X062M15 6x2x1,5 20,1 178, D.X082M15 8x2x1,5 22,0 235, D.X102M15 10x2x1,5 23,8 293, D.X12M15 12x2x1,5 25,3 350, D.X162M15 16x2x1,5 28,1 466, D.X202M15 20x2x1,5 30,6 581, D.X242M15 24x2x1,5 33,8 696, Other dimensions and colours available on request. 152

162 INSTRUMENTATION CABLES RE4XOHM1 (XLPE/LS0H) Conductor: Insulation: Colour core: Stranding: Screen Outer sheath: Flexible red copper conductor Cl. 5, acc to IEC XLPE compound blue,black with progressively numbered cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic, made up of an aluminium tape/polymer + tinned copper drain wire black (RAL 9005),or blue (RAL 5015) PVC, Halogen free compound Features: Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistence: 300/500 V 2 kv - 20 o C / + 90 o C - 5 o C / + 70 o C +160 o C Flame retardant acc. to: part /EN IEC low smoke emission: EN IEC Halogen free: acc.to IEC EN according to BS D.X022M05 2x2x0,50 10, D.X032M05 3x2x0,50 10, D.X042M05 4x2x0,50 11, D.X062M05 6x2x0,50 14, D.X122M05 12x2x0,50 15, D.X242M05 24x2x0,50 26, D.X022M07 2x2x0,75 10, D.X032M07 3x2x0,75 11, D.X042M07 4x2x0,75 12, D.X062M07 6x2x0,75 15, D.X122M07 12x2x0,75 20, D.X242M07 24x2x0,75 28, D.X022M10 2x2x1 11, D.X032M10 3x2x1 12, D.X042M10 4x2x1 13, D.X062M10 6x2x1 16, D.X122M10 12x2x1 22, D.X242M10 24x2x1 30, D.X022M15 2x2x1,5 13, D.X032M15 3x2x1,5 15, D.X042M15 4x2x1,5 15, D.X062M15 6x2x1,5 19, D.X122M15 12x2x1,5 25, D.X242M15 24x2x * For cables laying in earth a screen-cross section of 16 mm is permitted D.X023M05 2x3x0,50 10, D.X033M05 3x3x0,50 11, D.X043M05 4x3x0,50 12, D.X063M05 6x3x0,50 15, D.X123M05 12x3x0,50 20, D.X243M05 24x3x0,50 28, D.X023M07 2x3x0,75 11, D.X033M07 3x3x0,75 12, D.X043M07 4x3x0,75 13, D.X063M07 6x3x0,75 16, D.X123M07 12x3x0,75 21, D.X243M07 24x3x0,75 30, D.X023M10 2x3x1 12, D.X033M10 3x3x1 13, D.X043M10 4x3x1 14, D.X063M10 6x3x1 17, D.X123M10 12x3x1 23, D.X243M10 24x3x1 32, D.X023M15 2x3x1,5 14, D.X033M15 3x3x1,5 15, D.X043M15 4x3x1,5 18, D.X063M15 6x3x1,5 20, D.X123M15 12x3x1,5 27, D.X243M15 24x3x1,5 38, Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 153

163 INSTRUMENTATION CABLES RE4XHOHM1 (XLPE/LS0H) Conductor: Insulation: Colour core:: Stranding: Screen Individual: Overall: Outer sheath: Flexible red copper conductor Cl. 5, acc to IEC XLPE compound blue,black with progressively numbered cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic, made up of an aluminium tape/ polymer + tinned copper drain wire electrostatic, made up of an aluminium tape/ polymer+ tinned copper drain wire black (RAL 9005),or blue (RAL 5015) PVC, Halogen free compound Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistence: 300/500 V 2 kv - 30 o C / + 70 o C - 5 o C / + 70 o C +160 o C Flame retardant acc. to: EN IEC low smoke emission: EN IEC Halogen free: acc.to IEC EN Features: according to BS D.X022M05 2x2x0,50 10, D.X032M05 3x2x0,50 10, D.X042M05 4x2x0,50 11, D.X062M05 6x2x0,50 14, D.X122M05 12x2x0,50 15, D.X242M05 24x2x0,50 26, D.X022M07 2x2x0,75 10, D.X032M07 3x2x0,75 11, D.X042M07 4x2x0,75 12, D.X062M07 6x2x0,75 15, D.X122M07 12x2x0,75 20, D.X242M07 24x2x0,75 28, D.X022M10 2x2x1 11, D.X032M10 3x2x1 12, D.X042M10 4x2x1 13, D.X062M10 6x2x1 16, D.X122M10 12x2x1 22, D.X242M10 24x2x1 30, D.X022M15 2x2x1,5 13, D.X032M15 3x2x1,5 15, D.X042M15 4x2x1,5 15, D.X062M15 6x2x1,5 19, D.X122M15 12x2x1,5 25, D.X242M15 24x2x1,5 36, * For cables laying in earth a screen-cross section of 16 mm is permitted. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 47190D.X023M05 2x3x0,50 10, D.X033M05 3x3x0,50 11, D.X043M05 4x3x0,50 12, D.X063M05 6x3x0,50 15, D.X123M05 12x3x0,50 20, D.X243M05 24x3x0,50 28, D.X023M07 2x3x0,75 11, D.X033M07 3x3x0,75 12, D.X043M07 4x3x0,75 13, D.X063M07 6x3x0,75 16, D.X123M07 12x3x0,75 21, D.X243M07 24x3x0,75 30, D.X023M10 2x3x1 12, D.X033M10 3x3x1 13, D.X043M10 4x3x1 14, D.X063M10 6x3x1 17, D.X123M10 12x3x1 23, D.X243M10 24x3x1 32, D.X023M15 2x3x1,5 14, D.X033M15 3x3x1,5 15, D.X043M15 4x3x1,5 18, D.X063M15 6x3x1,5 20, D.X123M15 12x3x1,5 27, D.X243M15 24x3x1,5 38, Other dimensions and colours available on request. 154

164 INSTRUMENTATION CABLES RE4XOHEFR (XLPE/CAM/PE/SWA/PVC) Conductor: Insulation: Colour core: Stranding: Screen Inner sheath: Armouring: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC XLPE compound black/ gray cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic, made up of an aluminium tape/ polymer + tinned copper drain wire PE compound braid of galvanized steel wires black (RAL 9005), or blue (RAL 5015) PVC compound Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Min. bending radius: 300/500 V 2 kv - 30 o C / + 70 o C 0 o C / + 70 o C +160 o C 6 x d Resistance: Flame retardant acc. to: EN IEC Features: according to BS D.X022M05 2x2x0,50 12, D.X032M05 3x2x0, D.X042M05 4x2x0, D.X062M05 6x2x0, D.X122M05 12x2x0, D.X242M05 24x2x0, D.X022M07 2x2x0,75 12, D.X032M07 3x2x0, D.X042M07 4x2x0, D.X062M07 6x2x0, D.X122M07 12x2x0, D.X242M07 24x2x0, D.X022M10 2x2x D.X032M10 3x2x D.X042M10 4x2x D.X062M10 6x2x D.X122M10 12x2x D.X242M10 24x2x D.X022M15 2x2x1,5 14, D.X032M15 3x2x1, D.X042M15 4x2x1, D.X062M15 6x2x1, D.X122M15 12x2x1, D.X242M15 24x2x1, D.X023M05 2x3x0, D.X033M05 3x3x0, D.X043M05 4x3x0, D.X063M05 6x3x0, D.X123M05 12x3x0, D.X243M05 24x3x0, D.X023M07 2x3x0, D.X033M07 3x3x0, D.X043M07 4x3x0, D.X063M07 6x3x0, D.X123M07 12x3x0, D.X243M07 24x3x0, D.X023M10 2x3x D.X033M10 3x3x D.X043M10 4x3x D.X063M10 6x3x D.X123M10 12x3x D.X243M10 24x3x D.X023M15 2x3x1, D.X033M15 3x3x1, D.X043M15 4x3x1, D.X063M15 6x3x1, D.X123M15 12x3x1, D.X243M15 24x3x1, *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors Other dimensions and colours available on request. 155

165 INSTRUMENTATION CABLES RE4XHOHM1FM1 (XLPE/IAM/CAM/LS0H/SWA/LS0H) Conductor: Insulation: Colour core: Stranding: Screen: Individual: Overall: Inner sheath: Armouring: Outer sheath: stranded red copper conductor Cl. 2, acc to IEC XLPE compound /black/white cores twisted in pairs-triads. pairs-triads twisted in concentric layers electrostatic, made up of an aluminium tape/polymer + tinned copper drain wire electrostatic, made up of an aluminium tape/polymer + tinned copper drain wire halogen free compound braid of galvanized steel wires black (RAL 9005),or blue (RAL 5015), Halogen free compound Nominal voltage: Test voltage: Temperature range: Fixed installation: Flexible application: Max short circuit temperature: Resistance: 300/500 V 2 kv - 20 o C / + 90 o C 0 o C / + 70 o C 160 o C Flame retardant acc. to: EN / IEC low smoke emission: EN IEC Halogen free: acc.to IEC EN Features: according to BS D.X022M05 2x2x0,50 16, D.X023M05 2x3x0, D.X032M05 3x2x0, D.X033M05 3x3x0,50 17, D.X042M05 4x2x0, D.X043M05 4x3x0, D.X062M05 6x2x0, D.X063M05 6x3x0, D.X122M05 12x2x0, D.X123M05 12x3x0, D.X242M05 24x2x0, D.X243M05 24x3x0, D.X022M07 2x2x0,75 17, D.X023M07 2x3x0, D.X032M07 3x2x0, D.X033M07 3x3x0,75 17, D.X042M07 4x2x0, D.X043M07 4x3x0, D.X062M07 6x2x0, D.X063M07 6x3x0, D.X122M07 12x2x0, D.X123M07 12x3x0, D.X242M07 24x2x0, D.X243M07 24x3x0, D.X022M10 2x2x1 17, D.X023M10 2x3x D.X032M10 3x2x D.X033M10 3x3x1 17, D.X042M10 4x2x D.X043M10 4x3x D.X062M10 6x2x D.X063M10 6x3x D.X122M10 12x2x D.X123M10 12x3x D.X242M10 24x2x D.X243M10 24x3x D.X022M15 2x2x1,5 20, D.X023M15 2x3x1, D.X032M15 3x2x1, D.X033M15 3x3x1, D.X042M15 4x2x1, D.X043M15 4x3x1, D.X062M15 6x2x1, D.X063M15 6x3x1, D.X122M15 12x2x1, D.X123M15 12x3x1, D.X242M15 24x2x1, D.X243M15 24x3x1, Other dimensions and colours available on request. *the point of the code in the location of the coloring of the outer sheath gives tells us that this can be of different colors 156

166 SECURITY CABLES J-Y(St)Y Lg fire warning installation cable Conductor: solid red copper conductor 0,8 mmø Cl. 1, acc to IEC Insulation: PVC type YI1 Colour core: DIN VDE 0815 Stranding: cores twisted in pairs,pairs stranded in layers Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: red (RAL3000) with imprint BRANDMELDE KABLE,PVC type YM1 Features: Fire warning installation cable Nominal voltage: Testing voltage: Radiation resistance: Temperature range: fixed laying: flexible application: Loop resistance at 20 C: Min. bending radius: to DIN VDE 0891 part 5 during delivery: single bending without tension: repeated bending without tension: Insulation resistance: Mutual capacitance at 800 Hz: Capacitance unbalances at 800 Hz: Line attenuation: at 800 Hz: Resistance: max.300 V core/core U eff. 800 V core/screen 800 V up to 80x10 6 cj/kg (up to 80 Mrad) -30 C +70 C - 5 C to +50 C 0,6 mm-max. 73,2 Ohm/km 7,5 xd 2,5 xd 7,5 xd min.100 MOhmx/km max. 100 nf/km k 1 max.300 pf/100 m 1,48 db/km Flame retardant and self-extinguishing acc. to:din VDE 0482 part , EN IEC Outer-Ø ± 10% 49010CRW012M08 1x2x0,8 4, CRW022M08 2x2x0, CRW032M08 3x2x0,8 8, CRW042M08 4x2x0, CRW052M08 5x2x0,8 9, CRW062M08 6x2x0, CRW082M08 8x2x0,8 11, CRW102M08 10x2x0,8 13, CRW122M08 12x2x0,8 14, CRW142M08 14x2x0,8 14, CRW162M08 16x2x0, CRW202M08 20x2x0, CRW242M08 24x2x0, CRW302M08 30x2x0,8 20, CRW402M08 40x2x0, CRW502M08 50x2x0, CRW602M08 60x2x0, CRW802M08 80x2x0,8 31, CRWAA2M08 100x2x0, Other dimensions and colours available on request. 157

167 SECURITY CABLES J-H(St)H fire warning installation cable Conductor: solid red copper conductor 0,8 mmø Cl. 1, acc to IEC Insulation: Halogen-free compound type HI2 Colour core: DIN VDE 0815 Stranding: cores twisted in quads,quads stranded to units Wrapping: plastic tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: red (RAL3000) with imprint BRANDMELDE KABLE, Halogen-free compound type HM2 Features: Bd fire warning installaion cable Nominal voltage: 300 V Test voltage: 800 V Min.Bending radius: fixed laying: 2,5 x d flexible application: 7,5 x d Radiation resistance: up to 100x10 6 cj/kg Temperature range: - 30 C / + 70 C - 5 C / + 70 C Resistance: Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Outer-Ø ± 10% 49020CRW022M08 2x2x0,8 6, CRW042M08 4x2x0,8 10, CRW062M08 6x2x0,8 10, CRW102M08 10x2x0,8 13, CRW202M08 20x2x0,8 20, CRW302M08 30x2x0,8 21, CRW402M08 40x2x0,8 24, CRW502M08 50x2x0,8 27, CRW602M08 60x2x0,8 29, CRW802M08 80x2x0,8 33, CRWAA2M08 100x2x0,8 37, Other dimensions and colours available on request. 158

168 SECURITY CABLES JE-H(St)H Bd fire warning cable,fe 180/E 30 to E 90 (red),halogen-free Conductor: solid red copper conductor 0,8 mmø Cl. 1, acc to IEC Insulation: Halogen-free compound type HI2 Colour core: DIN VDE 0815 Stranding: cores twisted in quads,quads stranded to units Wrapping: plastic tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: red (RAL3000) with imprint BRANDMELDE KABLE, Halogen-free compound type HM2 Features: Bd fire warning installaion cable Nominal voltage: 300 V Test voltage: 800 V Min.Bending radius: fixed laying: 2,5 x d flexible application: 7,5 x d Radiation resistance: up to 100x10 6 cj/kg Temperature range: - 30 C / + 70 C - 5 C / + 70 C Resistance: Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Outer-Ø ± 10% 49030CRW022M08 2x2x0,8 7, CRW042M08 4x2x0,8 10, CRW082M08 8x2x0,8 16, CRW122M08 12x2x0,8 18, CRW162M08 16x2x0, CRW202M08 20x2x0,8 22, CRW322M08 32x2x0, CRW402M08 40x2x0,8 34, CRW522M08 52x2x0,8 37, Other dimensions and colours available on request. 159

169 SECURITY CABLES JE-H(St)HRH Bd fire warning cable,fe 180/E 30 to E 90,Halogen-free Conductor: solid red copper conductor 0,8 mmø Cl. 1, acc to IEC Insulation: Halogen-free compound type HI1 to DIN VDE 0207 part 23 flame retardant (E90 with special foil wrapping over conductor) Colour core: DIN VDE 0815 Stranding: 2 cores twisted to pair and each 4 pairs layed up in bunches,the bunches stranded in layers Wrapping: glass fibre tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Inner sheath: Armouring: flame retardant polyolefin compound to DIN VDE 0207 type HM3 Braid of galvanized steel wires Nominal voltage: Test voltage: Min.bending radius: Resistance: 300 V 800 V 6 x d Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer sheath: red (RAL3000) with imprint BRANDMELDE KABLE, Halogen-free compound type HM2 Features: FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 30: functionall for 30 min.test to DIN 4102 part.12 E 90: functionally for 90 min. Test to DIN 4102 part.12 Outer-Ø ± 10% 49040CRW022M08 2x2x0,8 10, CRW042M08 4x2x0,8 14, CRW082M08 8x2x0,8 21, CRW122M08 12x2x0,8 22, CRW162M08 16x2x0, CRW202M08 20x2x0,8 26, CRW322M08 32x2x0, CRW402M08 40x2x0, CRW522M08 52x2x0, Other dimensions and colours available on request. 160

170 SECURITY CABLES JE-H(St)H Orange Bd FE 180/E 30 to E 90 (orange),halogen-free Conductor: solid red copper conductor 0,8 mmø Cl. 1, acc to IEC Insulation: Halogen-free compound type HI1 to DIN VDE 0207 part.23 flame retardant (E90 with special foil wrapping over conductor) Colour core: DIN VDE 0815, (with ring colours and ring groups) Stranding: cores twisted in pair, 4 pairs to a unit and several units stranded to layers. Wrapping: special polyester tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: orange (RAL2003),flame retardant to DIN VDE 0207 part 24,Halogen free type HM2 Functionally E 30 to E 90 Features: FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 30: functionall for 30 min.test to DIN 4102 part.12 E 90: functionally for 90 min. Test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range fixed laying: flexible application: Resistance: 300 V 800 V 6 x d up to 100x10 6 cj/kg - 30 C to + 70 C - 5 C to + 50 C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Outer-Ø ± 10% 49050CGW012M08 1x2x0, CGW022M08 2x2x0,8 7, CGW042M08 4x2x0,8 10, CGW082M08 8x2x0,8 16, CGW122M08 12x2x0,8 18, CGW162M08 16x2x0,8 20, CGW202M08 20x2x0,8 22, CGW322M08 32x2x0,8 29, CGW402M08 40x2x0,8 34, CGW522M08 52x2x0,8 37, Functionally E 30 Outer-Ø ± 10% 49051CGW012M08 1x2x0, CGW022M08 2x2x0,8 7, CGW042M08 4x2x0,8 9, CGW082M08 8x2x0,8 11, CGW122M08 12x2x0, CGW162M08 16x2x0,8 15, CGW202M08 20x2x0,8 16, CGW322M08 32x2x0,8 20, CGW402M08 40x2x0,8 23, CGW522M08 52x2x0,8 25, Other dimensions and colours available on request. 161

171 SECURITY CABLES FTG10(O)M1 0,6/1 kv Conductor: Wrapping: Insulation: Outer sheat: flexible red copper conductor Cl. 5, acc to IEC glass/mica tape, wrapped to helix rubber type G10 blue (RAL 5012), halogen-free compound type M1 Features: Halogen-free Nominal voltage: Test voltage: Min. bending radius: Temperature range: fixed laying: flexible application: Temperature at conductor: in service: in short circuit: Resistance: 600/1000 V 1,2 kv 12 x d - 25 o C / +90 o C - 5 o C / +90 o C + 90 o C o C Fire resistaint acc. to: IEC 60331, EN Flame retardant and self-extinguishing acc. to: DIN VDE 0482 part , EN IEC Halogen free acc. to: IEC , EN DIN VDE 0482 part POWER 49060GBL010M15 1x1,5 7,2 14, GBL010M25 1x2,5 7, GBL010M40 1x4 8,2 38, GBL010M60 1x6 9 57, GBL010M61 1x10 10, GBL010M62 1x16 11,8 153, GBL010M63 1x25 12, GBL010M64 1x35 15, GBL010M65 1x50 16, GBL010M66 1x70 19, / GBL010M67 1x / GBL010M68 1x / GBL010M69 1x150 25, MCM 49060GBL010M70 1x185 27, MCM 49060GBL010M71 1x240 32, MCM 49060GBL010M72 1x300 34, MCM 49060GB3020M15 2x1,5 12,7 28, GB3020M25 2x2,5 14, GB3020M40 2x4 14,9 76, GB3020M60 2x6 16,1 115, GB3020M61 2x10 18, GB3020M62 2x , GB3020M63 2x GB3020M64 2x GB3030M15 3x1,5 13,4 43, GB3030M25 3x2,5 14, GB3030M40 3x4 15,6 115, GB3030M60 3x , GB3030M61 3x GB3030M62 3x16 21,8 460, GB3030M63 3x25 25, GB3030M64 3x35 28, GB3040M15 4x1, , GB3040M25 4x2,5 16, GB3040M40 4x4 17,1 153, GB3040M60 4x6 18,1 230, GB3040M61 4x10 21, GB3040M62 4x16 25,2 614, GB3040M63 4x25 29, GB3035M64 3x , GB3050M15 5x1,5 16, GB3050M25 5x2,5 17, GB3050M40 5x4 18, GB3050M60 5x6 19, GB3050M61 5x10 24, GB3050M62 5x16 28, GB3050M63 5x25 32, GB3050M64 5x35 36, Other dimensions and colours available on request. 162

172 SECURITY CABLES FTG10(O)M1 0,6/1 kv CONTROL Part no, No,of cores ca,mm approx, no,*) Part no, No,of cores ca,mm approx, no,*) 49060GB1071M15 7G1,5 17,5 100, GB1101M15 10G1,5 19, GB1121M15 12G1,5 21,9 172, GB1161M15 16G1,5 24,3 230, GB1191M15 19G1,5 27,5 273, GB1241M15 24G1,5 29,8 345, GB1071M25 7G2,5 18, GB1101M25 10G2,5 21, GB1121M25 12G2,5 23, GB1161M25 16G2,5 27, GB1191M25 19G2,5 28, GB1241M25 24G2,5 33, Other dimensions and colours available on request. 163

173 SECURITY CABLES FTG10(O)HM1 06/1 kv Conductor: flexible red copper conductor Cl. 5, acc to IEC Wrapping: glass/mica tape, wrapped to helix Insulation: rubber,type G10 Stranding: wires twisted together in concentric layers, wrapping overlapped polyester tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: red (RAL 3000),thermoplastic polyolefine, halogen-free compound,type M1 Features: Acc. to I UNEL conductor acc. to I 20-29, IEC insulation and sheath acc. to I compound lead-free acc. to I insulated cables fire resistant with elastometric compound with nominal voltage Uo/U 0,6/1 kv acc. to I Applications: screened cable for power, signaling and control elastometric isolated compound fire retardant, LS0H, with flexible wires protected by fire resistant barrier suitable for the power users emergency areas with danger of explosion or fire (exits and emergency lighting, Alarm signals, warning of smoke or gases, escalators, pumps, fire protection, fire curtains, etc.). Nominal voltage: 600/1000 V Test voltage: 4 kv Temperature range: -40/+90 C Min. bending radius: 10 x d Max. pulling installation: 50 N/mm 2 Resistance: Flame retardant and sel-extinguishing acc.to: PVC DIN VDE 0482 part /EN /IEC low corrisivenes gases and smoke opacity emissions during combustion acc. to: I 20-37, IEC 60754, IEC 61034, I Note: NoBurn cables with IMQ are marked: - I PH 90 (outer diameter up to 20 mm) they are fire-resistant complying with I 20-36/4-0 (EN50200) regulation, wich requires a minimum working time of the cables during the test, that is the cable has to be exposed to direct fire and mechanic shock for 120 minutes at 842 C. NoBurn are also no flame propagation on the single vertical element cables, compliyng with I (EN and IEC ) test. Moreover, the cables are made with special without halogen blends complying with I and NELEC regulation, in order to prevent any risk coming from any toxic substance issued during the combustion. That characteristic is verifed by many laboratory tests at IMQ and it limits the issue of corrosive, acid and toxic gas and the formation of murky smoke in the surrounding ambient in case of fire. NoBurn cables are made complying with I regulation and they are not included in I However, they have equivalent prescriptions about the test regarding the formation of toxic and corrosive smoke and gas 49070GR3020M10 2x1 7, GR3030M10 3x1 8, GR3040M10 4x1 9, GR3020M15 2x1,5 8, GR3030M15 3x1,5 9, GR3040M15 4x1,5 10, GR3020M25 2x2,5 10, GR3030M25 3x2,5 10, GR3040M25 4x2,5 12, GR1071M10 7G1 11, GR1071M15 7G1,5 12, Other dimension and colours available on request. 164

174 SECURITY CABLES N2XH-FE 180/E 30 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: core with double insulation: Flame retardant MICA-tape over conductor Core insulation with cross-linked polyethylene compound type 2XI1 to DIN VDE 0276 PART 604 Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers. Wrapping: halogen-free fillng compound,pressed Outer sheath: orange (RAL 2003),thermoplastic halogen-free polyolefine, flame retardant, type HM4 to DIN VDE 0276 part 604 Features: Security cable,0.6/1 kv,with improved fire characteristics Halogen-free acc.to DIN VDE 0482 part 267/EN /IEC (equivalent DIN VDE 0472 part 815) Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 30:functionally for 30 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 15 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part Outer-Ø ± 10% 49080GGL010M40 1x4 re GGL010M60 1x6 re GGL010M61 1x10 re GGL010M62 1x16 re 10, GGL010M63 1x25 rm GGL010M64 1x35 rm GGL010M65 1x50 rm 15, GGL010M66 1x70 rm 17, / GGL010M67 1x95 rm 19, / GGL010M68 1x120 rm / GGL010M69 1x150 rm MCM 49080GGL010M70 1x185 rm MCM 49080GGL010M71 1x240 rm MCM 49080GG3020M15 2x1,5 re 11, GG3020M25 2x2,5 re GG3020M40 2x4 re GG3020M60 2x6 re GG3020M61 2x10 re 15, GG3020M62 2x16 re 17, GG3020M63 2x25 rm GG3031M15 3G1,5 re GG3031M25 3G2,5 re 12, GG3031M40 3G4 re 13, GG3031M60 3G6 re 14, GG3031M61 3G10 re 16, GG3031M62 3G16 re 18, GG3031M63 3G25 rm 23, GG3035M63 3G25/16 rm 22, GG3031M64 3G35 rm GG3035M64 3G35/16 rm

175 SECURITY CABLES N2XH-FE 180/E 30 Outer-Ø ± 10% 49080GG3031M65 3G50 rm GG3035M65 3G50/25 rm GG3031M66 3G70 rm / GG3035M66 3G70/35 rm / GG3035M67 3G95/50 rm / GG3035M68 3G120/70 rm / GG3035M69 3G150/70 rm 48, MCM 49080GG3035M70 3G185/95 rm MCM 49080GG3041M15 4G1,5 re 12, GG3041M25 4G2,5 re GG3041M40 4G4 re GG3041M60 4G6 re 14, GG3041M61 4G10 re GG3041M62 4G16 re GG3040M63 4X25 re 23, GG3040M64 4X35 re 26, GG3040M65 4X50 re 29, GG3040M66 4X70 re 34, / GG3040M67 4X95 re / GG3040M68 4X120 re 43, / GG3051M15 5G1,5 re GG3051M25 5G2,5 re GG3051M40 5G4 re 14, GG3051M60 5G6 re 15, GG3051M61 5G10 re GG3051M62 5G16 re GG3050M63 5x25 re 24, GG3050M64 5x35 re 33, GG1071M15 7G1,5 re GG1121M15 12G1,5 re 16, Other dimensions and colours available on request. 166

176 SECURITY CABLES N2XCH-FE 180/E 30 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: core with double insulation: Flame retardant MICA-tape over conductor Core insulation with cross-linked polyethylene compound type 2XI1 to DIN VDE 0276 PART 604 Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers. Wrapping: halogen-free fillng compound,pressed Screen: concentric conductor of corrugated copper wires + copper tape Outer sheath: orange(ral 2003),thermoplastic halogen-free polyolefine, flame retardant, type HM4 to DIN VDE 0276 part 604 Features: Security cable,0.6/1 kv,with improved fire characteristics Halogen-free acc.to DIN VDE 0482 part 267/EN /IEC (equivalent DIN VDE 0472 part 815) Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 30:functionally for 30 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 15 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49090GG3020M15 2x1,5/1,5 re GG3020M25 2x2,5/2,5 re GG3020M40 2x4/4 re GG3020M60 2x6/6 re GG3020M61 2x10/10 re 17, GG3030M15 3x1,5/1,5 re GG3030M25 3x2,5/2,5 re GG3030M40 3x4/4 re 15, GG3030M60 3x6/6 re 16, GG3030M61 3x10/10 rm 18, GG3030M62 3x16/16 rm GG3030M63 3x25/16 rm 25, GG3030M64 3x35/16 rm GG3030M65 3x50/25 rm 31, GG3030M66 3x70/35 rm 36, / GG3030M67 3x95/50 rm / GG3030M68 3x120/70 rm / GG3030M69 3x150/70 rm

177 SECURITY CABLES N2XCH-FE 180/E 30 Outer-Ø ± 10% 49090GG3030M70 3x185/95 rm GG3030M71 3x240/120 rm 61, MCM 49090GG3040M15 4x1,5/1,5 re GG3040M25 4x2,5/2,5 re GG3040M40 4x4/4 re GG3040M60 4x6/6 re GG3040M61 4x10/10 re GG3040M62 4x16/16 re 22, GG3040M63 4x25/16 rm GG3040M64 4x35/16 rm 30, GG3040M65 4x50/25 rm GG3040M66 4x70/35 rm 39, / GG3040M67 4x95/50 rm 43, / GG3040M68 4x120/70 rm 49, / GG3040M69 4x150/70 rm 55, MCM 49090GG3040M70 4x185/95 rm MCM 49090GG3040M71 4x240/120 rm MCM 49090GG1070M15 7x1,5/2,5 re 16, GG1300M15 30x1,5/6 re Other dimensions and colours available on request. 168

178 SECURITY CABLES NHXH-FE 180/E 30 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: double core insulation of mica tape and cross-linked polymer type HI1,to DIN VDE 0207 part 23 Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers Wrapping: glass-fibre. Outer sheath: orange (RAL 2003),polymer compound DIN VDE 0207 part 24, flame retardant Features: Security cable,0.6/1 kv,with improved fire characteristics Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 30:functionally for 30 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 15 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49100GGL010M40 1x4 re GGL010M60 1x6 re 7, GGL010M61 1x GGL010M62 1x GGL010M63 1x25 10, GGL010M64 1x35 11, GGL010M65 1x GGL010M66 1x / GGL010M67 1x95 16, / GGL010M68 1x120 18, / GGL010M69 1x150 20, MCM 49100GGL010M70 1x MCM 49100GGL010M71 1x240 25, MCM 49100GGL010M72 1x300 31, MCM 49090GG3020M25 2x2,5 12, GG3020M40 2x4 13, GG3020M60 2x6 14, GG3020M61 2x GG3020M62 2x GG3020M63 2x GG3020M64 2x GG3030M15 3G1,5 12, GG3030M25 3G2,5 13, GG3030M40 3G4 14, GG3030M60 3G6 15, GG3030M61 3G GG3030M62 3G GG3030M63 3G25 22, GG3030M64 3G35 24, GG3030M65 3G50 27,

179 SECURITY CABLES NHXH-FE 180/E 30 Outer-Ø ± 10% 49100GG3030M66 3G70 rm / GG3030M67 3G95 rm 35, / GG3030M68 3G120 rm 39, / GG3030M69 3G150 rm MCM 49100GG3030M67 3G185 rm 49, MCM 49100GG3030M71 3G240 rm MCM 49100GG3040M15 4G1,5 re 13, GG3040M25 4G2,5 re GG3040M40 4G4 re 15, GG3040M60 4G6 re 16, GG3040M61 4G10 re 18, GG3040M62 4G16 rm 20, GG3040M63 4G25 rm 24, GG3040M64 4G35 rm GG3040M65 4G50 rm GG3040M66 4G70 rm / GG3040M67 4G95 rm 39, / GG3040M68 4G120 rm 43, / GG3040M69 4G150 rm MCM 49100GG3050M15 5G1,5 re GG3050M25 5G2,5 re GG3050M40 5G4 re 16, GG3050M60 5G6 re GG3050M61 5G10 re GG3050M62 5G16 rm 22, GG3050M63 5G25 rm 26, GG3050M64 5G35 rm GG1070M15 7G1,5 re GG1070M25 7G2,5 re 16, GG1100M15 10G1,5 re GG1100M25 10G2,5 re GG1120M15 12G1,5 re GG1120M25 12G2,5 re 20, GG1140M15 14G1,5 re GG1140M25 14G2,5 re 21, GG1190M15 19G1,5 re 21, GG1190M25 19G2,5 re 23, GG1240M15 24G1,5 re GG1240M25 24G2,5 re GG1300M25 30G1,5 re GG1300M25 30G2,5 re 28, Other dimensions and colours available on request. 170

180 SECURITY CABLES NHXCH-FE 180/E 30 Conductor: solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: special core insulation of mica tape and cross-linked polymer type HI1,acc.to DIN VDE 0207 part 23 Colour core: DIN VDE Stranding: cores stranded in layers Wrapping: glass-fibre Screen: red copper wires and one or two copper tape(s) applied helically Outer sheath: orange (RAL 2003),polymer compound DIN VDE 0207 part 24, flame retardant Features: Security cable,0.6/1 kv,with improved fire characteristics Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 30:functionally for 30 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 15 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49110GG3020M15 2x1,5/1,5 re GG3020M25 2x2,5/2,5 re 13, GG3020M40 2x4/4 re 14, GG3020M60 2x6/6 re GG3020M61 2x10/10 re GG3030M15 3x1,5/1,5 re 13, GG3030M25 3x2,5/2,5 re 14, GG3030M40 3x4/4 re 15, GG3030M60 3x6/6 re 16, GG3030M61 3x10/10 re 18, GG3030M62 3x16/16 rm 20, GG3030M63 3x25/16 rm GG3030M64 3x35/16 rm 26, GG3030M65 3x50/25 rm 29, GG3030M66 3x70/35 rm / GG3030M67 3x95/50 rm 37, / GG3030M68 3x120/70 rm 42, / GG3030M69 3x150/70 rm GG3030M70 3x185/95 rm 52, GG3030M71 3x240/120 rm 58, MCM 49110GG3040M15 4x1,5/1,5 re 14, GG3040M25 4x2,5/2,5 re 15, GG3040M40 4x4/4 re 16, GG3040M60 4x6/6 re 17,

181 SECURITY CABLES NHXCH-FE 180/E 30 Outer-Ø ± 10% 49110GG3040M61 4x10/10 re GG3040M62 4x16/16 re GG3040M63 4x25/16 rm GG3040M64 4x35/16 rm 28, GG3040M65 4x50/25 rm GG3040M66 4x70/35 rm / GG3040M67 4x95/50 rm 41, / GG3040M68 4x120/70 rm / GG3040M69 4x150/70 rm MCM 49110GG3040M70 4x185/95 rm MCM 49110GG3040M71 4x240/120 rm MCM 49110GG1070M15 7x1,5/2,5 re 16, GG1070M25 7x2,5/2,5 re 17, GG1100M15 10x1,5/2,5 re 19, GG1100M25 10x2,5/4 re GG1120M15 12x1,5/2,5 re GG1120M25 12x2,5/4 re 21, GG1240M15 24x1,5/6 re GG1240M25 24x2,5/6 re 28, GG1300M15 30x1,5/6 re GG1300M25 30x2,5/10 re Other dimensions and colours available on request. 172

182 SECURITY CABLES N2XH-FE 180/E 90 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: core insulation with cross-linked polyethylene. type 2XI1 to DIN VDE 0276 PART 604. core with double insulation.flame retardant MICA-tapeover conductor. Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers. Wrapping: halogen-free fillng compound,pressed. Outer sheath: orange (RAL 2003),thermoplastic halogen-free polyolefine compound,type HM4 to DIN VDE 0276 part 604, flame retardant. Features: Security cable,0.6/1 kv,with improved fire characteristics Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 90:functionally for 90 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 12 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49120GGL010M62 1x16 rm 11, GGL010M63 1x25 rm GGL010M64 1x35 rm GGL010M65 1x50 rm 15, GGL010M66 1x70 rm 17, / GGL010M67 1x95 rm 19, / GGL010M68 1x120 rm 21, / GGL010M69 1x150 rm 23, MCM 49120GGL010M70 1x185 rm 25, MCM 49120GGL010M71 1x240 rm 28, MCM 49120GGL010M72 1x300 rm MCM 49120GGL010M73 1x400 rm 34, MCM 49120GG3020M15 2x1,5 re 14, GG3020M25 2x2,5 re 15, GG3020M40 2x4 re 16, GG3020M60 2x6 re 17, GG3020M61 2x10 rm 19, GG3020M62 2x16 rm GG3020M63 2x25 rm 23, GG3020M64 2x35 rm 26, GG3020M65 2x50 rm GG3020M66 2x70 rm / GG3020M67 2x95 rm 37, / GG3020M68 2x120 rm 41, / GG3030M15 3x1,5 re GG3030M25 3x2,5 re GG3030M40 3x4 re GG3030M60 3x6 re

183 SECURITY CABLES N2XH-FE 180/E 90 Outer-Ø ± 10% 49120GG3030M61 3x10 rm 20, GG3030M62 3x16 rm 22, GG3030M63 3x25 rm GG3035M64 3x35/16 rm 29, GG3030M64 3x35 rm GG3035M65 3x50/25 rm 33, GG3030M65 3x50 rm GG3030M66 3x70 rm 35, / GG3035M66 3x70/35 rm / GG3035M67 3x95/50 rm / GG3030M67 3x95 rm 40, / GG3035M68 3x120/70 rm 46, / GG3030M68 3x120 rm / GG3030M69 3x150 rm 48, MCM 49120GG3035M69 3x150/70 rm MCM 49120GG3035M70 3x185/95 rm 55, MCM 49120GG3030M70 3x185 rm MCM 49120GG3035M71 3x240/120 rm 61, MCM 49120GG3030M71 3x240 rm 59, MCM 49120GG3040M15 4x1,5 re 16, GG3040M25 4x2,5 re 17, GG3040M40 4x4 re 18, GG3040M60 4x6 re 19, GG3040M61 4x10 rm 22, GG3040M62 4x16 rm 24, GG3040M63 4x25 rm 28, GG3040M64 4x35 rm GG3040M65 4x50 rm GG3040M66 4x70 rm / GG3040M67 4x95 rm / GG3040M68 4x120 rm 48, / GG3040M69 4x150 rm MCM 49120GG3040M70 4x185 rm MCM 49120GG3040M71 4x240 rm MCM 49120GG3050M15 5x1,5 re GG3050M25 5x2,5 re GG3050M40 5x4 re GG3050M60 5x6 re 21, GG3050M61 5x10 rm 24, GG3050M62 5x16 rm GG3050M63 5x25 rm GG3050M64 5x35 rm GG3050M65 5x50 rm 38, GG3050M66 5x70 rm 43, / GG1070M15 7x1,5 re 19, GG1070M25 7x2,5 re 20, GG1070M40 7x4 re GG1100M15 10x1,5 re GG1100M25 10x2,5 re 25, GG1120M15 12x1,5 re 24, GG1120M25 12x2,5 re GG1240M15 24x1,5 re Other dimensions and colours available on request. 174

184 SECURITY CABLES N2XCH-FE 180/E 90 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: core insulation with cross-linked polyethylene. type 2XI1 to DIN VDE 0276 PART 604. core with double insulation.flame retardant MICA-tapeover conductor. Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers. Wrapping: halogen-free fillng compound,pressed. Screen: concentric conductor of corrugated copper wires + copper tape Outer sheath: orange (RAL 2003),thermoplastic halogen-free polyolefine compound,type HM4 to DIN VDE 0276 part 604, flame retardant. Features: Security cable,0.6/1 kv,with improved fire characteristics Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 90:functionally for 90 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 12 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49130GG3030M15 3x1,5/1,5 re 16, GG3030M25 3x2,5/2,5 re 17, GG3030M40 3x4/4 re 18, GG3030M60 3x6/6 re GG3030M61 3x10/10 re GG3030M62 3x16/16 rm 24, GG3030M63 3x25/16 rm GG3030M64 3x35/16 rm 30, GG3030M65 3x50/25 rm GG3030M66 3x70/35 rm 37, / GG3030M67 3x95/50 rm / GG3030M68 3x120/70 rm / GG3030M69 3x150/70 rm MCM 49130GG3030M70 3x185/95 rm 57, MCM 49130GG3030M71 3x240/120 rm 63, MCM 49130GG3040M15 4x1,5/1,5 re 17, GG3040M25 4x2,5/2,5 re GG3040M40 4x4/4 re

185 SECURITY CABLES N2XCH-FE 180/E 90 Outer-Ø ± 10% 49130GG3040M60 4x6/6 re 21, GG3040M61 4x10/10 rm GG3040M62 4x16/16 rm 26, GG3040M63 4x25/16 rm 30, GG3040M64 4x35/16 rm GG3040M65 4x50/25 rm 37, GG3040M66 4x70/35 rm 41, / GG3040M67 4x95/50 rm 47, / GG3040M68 4x120/70 rm 52, / GG3040M69 4x150/70 rm 57, MCM 49130GG3040M70 4x185/95 rm 63, MCM 49130GG3040M71 4x240/120 rm MCM 49130GG1070M15 7x1,5/2,5 re 20, GG1070M25 7x2,5/2,5 re GG1120M15 12x1,5/2,5 re GG1120M25 12x2,5/2,5 re GG1240M15 24x1,5/6 re GG1240M25 24x2,5/10 re 37, GG1300M15 30x1,5/6 re GG1300M25 30x2,5/10 re 39, Other dimensions and colours available on request. 176

186 SECURITY CABLES NHXH-FE 180/E 90 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: double core insulation of mica tape and cross-linked polymer type HI1,to DIN VDE 0207 part 23 Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers. Wrapping: halogen-free fillng compound,pressed. Outer sheath: orange (RAL 2003),thermoplastic,polyolefine compound, type HM4 to DIN VDE 0276 part 604,flame retardant. Features: Security cable,0.6/1 kv,with improved fire characteristics Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 90:functionally for 90 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 12 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49140GG3030M15 3x1,5 re GG3030M25 3x2,5 re GG3030M40 3x4 re GG3030M60 3x6 re GG3030M61 3x10 re GG3030M62 3x16 re GG3030M63 3x25 re GG3030M64 3x35 re GG3035M64 3x35/16 re GG3035M65 3x50/25 rm GG3035M66 3x70/35 rm / GG3035M67 3x95/50 rm / GG3035M68 3x120/70 rm / GG3035M69 3x150/70 rm MCM 49140GG3035M70 3x185/95 rm MCM 49140GG3035M71 3x240/120 rm MCM 49140GG3040M15 4x1,5 re GG3040M25 4x2,5 re GG3040M40 4x4 re GG3040M60 4x6 re GG3040M61 4x10 re GG3040M62 4x16 re GG3040M63 4x25 re GG3040M64 4x35 re

187 SECURITY CABLES NHXH-FE 180/E 90 Outer-Ø ± 10% 49140GG3040M65 4x GG3040M66 4x / GG3040M67 4x / GG3040M68 4x / GG3050M15 5x1, GG3050M25 5x2, GG3050M40 5x GG3050M60 5x GG3050M61 5x GG3050M62 5x GG3050M63 5x GG3050M64 5x GG3050M65 5x GG1070M15 7x1, GG1070M25 7x2, GG1100M15 10x1, GG1100M25 10x2, GG1120M15 12x1, GG1120M25 12x2, Other dimensions and colours available on request. 178

188 SECURITY CABLES NHXCH-FE 180/E 90 Conductor: Solid or stranded red copper conductor Cl. 1 or 2,acc. to IEC DIN VDE 0259 Insulation: double core insulation of mica tape and cross-linked polymer type HI1,to DIN VDE 0207 part 23 Colour core: DIN VDE and 0276 part 604 Stranding: cores stranded in layers. Wrapping: glass-fibre. (also for each single core). Screen: red copper wires and one or two copper tape(s) applied helically Outer sheath: orange (RAL 2003),polyolefin compound type HM4 DIN VDE 0207 part 24 Features: Security cable,0.6/1 kv,with improved fire characteristics Insulation integrity under flame propagation to VDE 0472 part 814 IEC Burning behavior in fire(funtionality) of the complete cable system to DIN 4102 part 12 (30 min.) FE 180: insulation integrity for 180 min. Test to DIN VDE 0472 part.814 IEC E 90:functionally for 90 min.test to DIN 4102 part.12 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range: Resistance: 600/1000 V 4 kv 12 x d up to 200x10 6 cj/kg - 30 o C to + 70 o C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC , DIN VDE 0482 part Outer-Ø ± 10% 49150GG3030M15 3x1,5/1,5 re 16,9 66,0 380, GG3030M25 3x2,5/2,5 re 18,0 104,0 430, GG3030M40 3x4/4 re 19,0 161,0 530, GG3030M60 3x6/6 re 20,1 240,0 640, GG3030M61 3/10/10 re 22,0 408,0 850, GG3030M62 3x16/16 rm 24,0 643,0 1150, GG3030M63 3x25/16 rm 28,0 902,0 1700, GG3030M64 3x35/16 rm 30,0 1190,0 2150, GG3030M65 3x50/25 rm 34,0 1723,0 2800, GG3030M66 3x70/35 rm 38,0 2410,0 3800,0 2/ GG3030M67 3x95/50 rm 44,0 3296,0 5100,0 3/ GG3030M68 3x120/70 rm 47,0 4236,0 6250,0 4/ GG3030M69 3x150/70 rm 51,0 4992,0 6900,0 250 MCM 49150GG3030M70 3x185/95 rm 56,0 6383,0 8550,0 350 MCM 49150GG3030M71 3x240/120 rm 65,0 8242, ,0 450 MCM 49150GG3040M15 4x1,5/1,5 re 18,0 81,0 435, GG3040M25 4x2,5/2,5 re 18,9 128,0 500, GG3040M40 4x4/4 re 20,0 200,0 610, GG3040M60 4x6/6 re 21,0 297,0 740, GG3040M61 4x10/10 re 23,0 504,0 1050, GG3040M62 4x16/16 re 25,0 796,0 1350, GG3040M63 4x25/16 re 30,0 1142,0 1950, GG3040M64 4x35/16 re 33,0 1526,0 2400,0 2 Other dimensions and colours available on request. 179

189 SECURITY CABLES NHXCH-FE 180/E 90 Outer-Ø ± 10% 49150GG3040M65 4X50/25 rm 37,0 2203,0 3200, GG3040M66 4X70/35 rm 42,0 3082,0 4300,0 2/ GG3040M67 4X95/50 rm 47,0 4208,0 5750,0 3/ GG3040M68 4X120/70 rm 51,0 5388,0 7100,0 4/ GG3040M69 4X150/70 rm 56,0 6540,0 8550,0 250 MCM 49150GG3040M70 4X185/95 rm 68,0 8159, ,0 350 MCM 49150GG3040M71 4X240/120 rm 70, , ,0 450 MCM 49150GG3050M25 5X2,5/2,5 re - 152,0 480, GG1070M15 7X1,5/2,5 re 21,0 133,0 520, GG1070M25 7X2,5/2,5 re 21,0 200,0 630, GG1120M15 12X1,5/2,5 re 27,0 205,0 770, GG1120M25 12X2,5/4 re 28,0 334,0 950, GG1240M15 24X1,5/6 re 37,0 413,0 1380, GG1240M25 24X2,5/10 re 37,5 696,0 1750, GG1300M15 30X1,5/6 re 39,0 499,0 1360, GG1300M25 30X2,5/10 re 39,5 840,0 2080,0 14 Other dimensions and colours available on request. 180

190 SECURITY CABLES FG4OHM1 PH /100 V Conductor: flexible red copper conductor Cl. 5, acc to IEC Insulation: Colour core: Screen: Outer sheath: silicon,type EI2 red/black electrostatic screen of plastic and aluminium tape + tinned drain-wire red (RAL 3000),thermoplastic polyolefine, halogen-free compound,type M1 Features: Fire warning installation cable PH30: at 830 C flame and shock for 30 minutes Nominal voltage: Test voltage: Temperature at conductor: in service: in short circuit: Min. bending radius: Resistance: 100/100 V 2 kv + 90 o C o C 14 x d Fire resistant acc. to: IEC , I EN Halogen free acc. to: IEC ,I EN /2 Outer-Ø ± 10% 49160BRM020M05 2X0,5 6,1 14, BRM020M07 2X0,75 6,4 19, BRM020M10 2X1 7, BRM020M15 2X1,5 8,1 33, BRM020M25 2X2,5 9,3 52, Other dimensions and colours available on request. 181

191 SECURITY CABLES FG4OHM1 PH /750 V Conductor: stranded red copper conductor Cl. 2, acc to IEC Insulation: high performance silicon Colour core: HD 308 Outer sheath: red (RAL 3000),thermoplastic halogen-free compound Nominal voltage: Temperature range: Min. bending radius: Resistance: 450/750 V - 40 o C to + 90 o C 10 x d Fire resistant acc. to: IEC , I EN Halogen free acc. to: IEC ,I EN /2 Features: Fire warning installation cable PH90: at 830 C flame and shock for 90 minutes Outer-Ø ± 10% 49170ER3020M15 2x1,5 7, ER3030M15 3x1,5 8,3 43, ER3040M15 4x1,5 9,3 57, ER3050M15 5x1,5 10, ER3020M25 2x2,5 9,2 52, ER3030M25 3x2,5 9, ER3040M25 4x2,5 11, ER3050M25 5x2,5 12, ER3020M40 2x4 10,5 76, ER3030M40 3x4 11,6 115, ER3040M40 4x4 12,5 153, ER3050M40 5x Other dimensions and colours available on request. 182

192 SECURITY CABLES FG4OHM1 PH /750 V Conductor: stranded red copper conductor Cl. 5, acc to IEC Insulation: high performance silicon Colour core: HD 308 Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: red (RAL 3000),thermoplastic halogen-free compound Nominal voltage: Temperature range: Min. bending radius: Resistance: 450/750 V - 40 o C to + 90 o C 8 x d Fire resistant acc. to: IEC , I EN Halogen free acc. to: IEC ,I EN /2 Features: Fire warning installation cable PH120: at 830 C flame and shock for 120 minutes Outer-Ø ± 10% 49180ER3020M07 2X0,75 7,6 19, ER3030M07 3X0, , ER3040M07 4X0,75 8,7 33, ER3020M10 2X ER3030M10 3X1 8,2 33, ER3040M10 4X1 8,9 43, ER3070M10 7X1 70, ER3120M10 12X1 13, ER3190M10 19X1 16,4 187, ER3020M15 2X1,5 8,3 33, ER3030M15 3X1,5 8, ER3040M15 4X1,5 9,8 62, ER3070M15 7X1,5 11,7 105, ER3120M15 12X1,5 15,3 177, ER3190M15 19X1,5 18,2 278, ER3020M25 2X2,5 9,8 52, ER3030M25 3X2,5 10,4 76, ER3040M25 4X2,5 11,4 100, ER3070M25 7X2,5 13,4 172, ER3120M25 12X2,5 17,9 292, ER3190M25 19X2,5 21,1 460, Other dimensions and colours available on request. 183

193

194 TELEPHONE AND ELECTRONIC CABLES A-2Y(L)2Y Conductor: solid red copper conductor 0,6 and 0,8 mmø Cl. 1, acc to IEC Insulation: PE,type 2YI1 Stranding: 4 cores twisted to a star quad,5 star quads stranded to sub-units,each 5 or 10 sub units stranded to main units stranded to cable core. Colour core: DIN VDE 0816 Wrapping: plastic foil Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: black(ral 9005),PE type 2Y Nominal voltage: Testing voltage: Temperature range: fixed laying: flexible application: Loop resistance at 20 C: Min. bending radius: Radiation resistance: max 300 V core/core U eff. 500 V core/screen U eff V max +70 C - 20 C to +50 C 0,6 mm=130 Ohm/km 0,6 mm=1,04 Ohm/km 10 x d up to 80x10 6 cj/kg (up to 80 Mrad) Insulation resistance: min.5 GOhmx/km Features: Bd telephone-outdoor cable Line attenuation: of side circuites at 800 Hz: 0,6 mm=1,04 db/km 0,8 mm=0,78 db/km according to VDE 0816 Laminated sheath Unfilled Impedance of side circuites: 0,6 mm=720 Ohm 0,8 mm=520 Ohm Vart no. No.of Vairs x Ø Outer-Ø ± 10% CoVVer 50010C7V022M06 2x2x0, C7V042M06 4x2x0, C7V062M06 6x2x0,6 11, C7V102M06 10x2x0,6 12, C7V202M06 20x2x0,6 15, C7V302M06 30x2x0,6 17, C7V402M06 40x2x0,6 19, C7V502M06 50x2x0, C7V702M06 70x2x0,6 24, C7VAA2M06 100x2x0, C7VAB2M06 150x2x0, C7VAC2M06 200x2x0, C7VAD2M06 250x2x0,6 40, C7VAE2M06 300x2x0, C7VAF2M06 350x2x0,6 47, C7VAG2M06 400x2x0,

195 TELEPHONE TELEPHONE AND ELECTRONIC CABLES CABLES A-2Y(L)2Y No.of pairs x Ø Outer-Ø ± 10% 50010C7V022M08 2x2x0, C7V042M08 4x2x0, C7V062M08 6x2x0, C7V102M08 10x2x0,8 14, C7V202M08 20x2x0, C7V302M08 30x2x0, C7V402M08 40x2x0, C7V502M08 50x2x0,8 25, C7V702M08 70x2x0, C7VAA2M08 100x2x0, C7VAB2M08 150x2x0, C7VAC2M08 200x2x0,8 46, C7VAD2M08 250x2x0, C7VAE2M08 300x2x0, C7VAF2M08 350x2x0,8 56, C7VAG2M08 400x2x0, C7VAH2M08 500x2x0, C7VAI2M08 600x2x0, Other dimensions and colours available on request. Mutual capacitance: at 800 Hz Capacitance unbalances at 800 Hz of all values 100% of all values k 1 100%-max.800 pf/300 m 0.6 mm-max.52 nf/km of all values k 1 98%-max.400 pf/300 m 0.8 mm-max.55 nf/km of all values k %-max.300 pf/300 m of all values 95% of all values k %-max.100 pf/300 m 0.6 mm-max.50 nf/km 0.8 mm-max.53 nf/km of all values 80% 0.6 mm-max.48 nf/km 0.8 mm-max.50 nf/km 186

196 TELEPHONE AND ELECTRONIC CABLES A-2YF(L)2Y Conductor: solid red copper conductor 0,6 and 0,8 mmø Cl. 1, acc to IEC Insulation: PE,type 2Y Stranding: 4 cores twisted to a star quad,5 star quads stranded to sub-units,each 5 or 10 sub units stranded to main units stranded to cable core. Colour core: DIN VDE 0816 Wrapping: paper tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: black(ral 9005),PE type 2Y Nominal voltage: Testing voltage: Radiation resistance: Temperature range: fixed laying: flexible application: Loop resistance at 20 C: Min. bending radius: max 300 V core/core U eff. 500 V core/screen U eff V up to 80x10 6 cj/kg (up to 80 Mrad) max +70 C - 20 C to +50 C 0,6 mm=130 Ohm/km 0,6 mm=1,04 Ohm/km 10 x d Insulation resistance: min.1,5 GOhmx/km Features: Bd telephone-outdoor cable according to VDE 0816 Laminated sheath Filled cable core Line attenuation: of side circuites at 800 Hz: Impedance of side circuites: 0,6 mm=1,04 db/km 0,8 mm=0,78 db/km 0,6 mm=720 Ohm 0,8 mm=520 Ohm longitudinally water proof Vart no. No.of Vairs x Ø Outer-Ø ± 10% CoVVer 50020C7V022M06 2x2x0,6 7, C7V042M06 4x2x0, C7V062M06 6x2x0, C7V102M06 10x2x0,6 13, C7V202M06 20x2x0, C7V302M06 30x2x0, C7V402M06 40x2x0,6 20, C7V502M06 50x2x0, C7V702M06 70x2x0, C7VAA2M06 100x2x0,6 31, C7VAB2M06 150x2x0,6 37, C7VAC2M06 200x2x0,6 42, C7VAD2M06 250x2x0,6 47, C7VAE2M06 300x2x0,6 51, C7VAF2M06 350x2x0, C7VAG2M06 400x2x0,6 60, C7VAH2M06 500x2x0,6 60,

197 TELEPHONE TELEPHONE AND ELECTRONIC CABLES CABLES A-2YF(L)2Y Vart no. No.of Vairs x Ø Outer-Ø ± 10% CoVVer 50020C7V022M08 2x2x0,8 8,5 20, C7V042M08 4x2x0, , C7V062M08 6x2x0,8 12,5 60, C7V102M08 10x2x0, , C7V202M08 20x2x0, , C7V302M08 30x2x0, , C7V402M08 40x2x0, , C7V502M08 50x2x0, , C7V702M08 70x2x0, , C7VAA2M08 100x2x0, , C7VAB2M08 150x2x0, , C7VAC2M08 200x2x0, , C7VAD2M08 250x2x0, , C7VAE2M08 300x2x0,8 62,5 3016, C7VAF2M08 350x2x0, , C7VAG2M08 400x2x0, , C7VAH2M08 500x2x0,8 81,5 5027, Other dimensions and colours available on request. Mutual capacitance: at 800 Hz Capacitance unbalances at 800 Hz of all values 100% of all values k 1 100%-max.800 pf/300 m 0.6 mm-max.52 nf/km of all values k 1 98%-max.400 pf/300 m 0.8 mm-max.55 nf/km of all values k %-max.300 pf/300 m of all values 95% of all values k %-max.100 pf/300 m 0.6 mm-max.50 nf/km 0.8 mm-max.53 nf/km of all values 80% 0.6 mm-max.48 nf/km 0.8 mm-max.50 nf/km 188

198 TELEPHONE AND ELECTRONIC CABLES A-Y(St)YSYv Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: PVC,type YI1 Stranding: cores twisted into pairs, 4 pairs layed up into sub-units (2-pairs cable stranded as one star quad), sub-units layed up in layers. Cores colour: blue, red, grey, yellow,green, brown, white, black (in sequence) DIN VDE 0816 Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Wrapping: plastic foil Nominal voltage: Testing voltage: Temperature range: fixed laying: flexible application: Min. bending radius: Operating capacity: Insulation resistance: Loop resistance: 300 V 500 V -30/+70 C - 5/+50 C 10 x Ø 120 nf/km 100 MOhmx/km 73,2 Ohm/km Inner sheath: PVC,type YM1 Armouring: braid of galvanized steel wires Outer sheath: black (RAL 9005),PVC type YM1 Features: Acc. to VDE 0815 UV resistant underground use rodent protection Applications: For fixed installation, indoors, outdoors. in ground, as well as in concrete. Vart no. No.of Vairs x Ø Outer-Ø ± 10% CoVVer 50030C7V022M08 2x2x0,8 SW 11, C7V042M08 4x2x0,8 SW 12, C7V082M08 8x2x0,8 SW 15, C7V122M08 12x2x0,8 SW 16, C7V202M08 20x2x0,8 SW 19, C7V402M08 40x2x0,8 SW 26, Other dimensions and colours available on request. 189

199 TELEPHONE AND ELECTRONIC CABLES J-YY Bd Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: PVC core insulation,compound type YI1 to DIN VDE 0207,insulation wall-thickness 0,2 mm to table 7 Colour core: DIN VDE 0815 Stranding: the cores to a quad each 5 quads to a unit and several units are stranded in layer Wrapping: plastic tape Outer sheath: grey (RAL 7032),PVC,type YM1 Features: Telephone installation cable According to VDE 0815 Nominal voltage: Testing voltage: (50 Hz) Radiation resistance: Temperature range: fixed laying: flexible application: Loop resistance at 20 C: Min. bending radius: to DIN VDE 0891 part 5 during delivery: single bending without tension: repeated bending without tension: Insulation resistance: Mutual capacitance at 800 Hz: Capacitance unbalances at 800 Hz: Line attenuation: at 800 Hz: Resistance: max 300 V core/core U eff. 800 V up to 80x10 6 cj/kg (up to 80 Mrad) -30 C +70 C - 5 C to +50 C max. 130 Ohm/km 7,5 xd 2,5 xd 7,5 xd min.100 MOhmx/km max. 100 nf/km k 1 max.300 pf/100 m k 9 k pf/100 m 1,48 db/km Flame retardant and self-extinguishing acc. to:din VDE 0482 part , EN IEC No.of pairs x Ø Outer-Ø ± 10% 50040C6W022M06 2x2x0,6 4, C6W042M06 4x2x0,6 6, C6W062M06 6x2x0, C6W102M06 10x2x0,6 8, C6W162M06 16x2x0, C6W202M06 20x2x0, C6W242M06 24x2x0,6 11, C6W302M06 30x2x0, C6W402M06 40x2x0, C6W502M06 50x2x0,6 16, C6W602M06 60x2x0,6 17, C6W802M06 80x2x0,6 20, C6WAA2M06 100x2x0,6 22, Other dimensions and colours available on request. 190

200 TELEPHONE AND ELECTRONIC CABLES J-Y(St)Y Lg Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: PVC core insulation,compound type YI1 to DIN VDE 0207,insulation wall-thickness 0,2 mm to table 7 Colour core: DIN VDE 0816 Stranding: the cores to a quad each 5 quads to a unit and several units are stranded in layer Wrapping: tinned copper drain wire,plastic coated Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: grey (RAL 7032),PVC type YM1 Features: Telephone installation cable According to VDE 0815 Nominal voltage: Testing voltage: Radiation resistance: Temperature range: fixed laying: flexible application: Loop resistance at 20 C: Min. bending radius: to DIN VDE 0891 part 5 during delivery: single bending without tension: repeated bending without tension: Insulation resistance: Mutual capacitance at 800 Hz: Capacitance unbalances at 800 Hz: Line attenuation: at 800 Hz: Resistance: 0,6 mm-300 V 0,8 mm-300 V core/core U eff. 800 V core/screen 800 V up to 80x10 6 cj/kg (up to 80 Mrad) -30 C +70 C - 5 C to +50 C 0,6 mm-max. 130 Ohm/km 0,6 mm-max. 73,2 Ohm/km 7,5 xd 2,5 xd 7,5 xd min.100 MOhmx/km max. 100 nf/km k 1 max.300 pf/100 m k 9 k pf/100 m 1,48 db/km Flame retardant and self-extinguishing acc. to:din VDE 0482 part , EN IEC No.of pairs x Ø Outer-Ø ± 10% 50050C6W022M06 2x2x0, C6W032M06 3x2x0,6 6, C6W042M06 4x2x0,6 6, C6W052M06 5x2x0,6 7, C6W062M06 6x2x0,6 7, C6W082M06 8x2x0, C6W102M06 10x2x0, C6W122M06 12x2x0,6 10, C6W162M06 16x2x0, C6W202M06 20x2x0, C6W242M06 24x2x0, C6W302M06 30x2x0, C6W402M06 40x2x0, C6W502M06 50x2x0, C6W602M06 60x2x0, C6W802M06 80x2x0, C6WAA2M06 100x2x0,

201 TELEPHONE AND ELECTRONIC CABLES J-Y(St)Y Lg No.of pairs x Ø Outer-Ø ± 10% 50050C6W022M08 2x2x0, C6W032M08 3x2x0,8 8, C6W042M08 4x2x0, C6W052M08 5x2x0,8 9, C6W062M08 6x2x0, C6W082M08 8x2x0,8 11, C6W102M08 10x2x0,8 13, C6W122M08 12x2x0,8 14, C6W162M08 16x2x0, C6W202M08 20x2x0, C6W242M08 24x2x0, C6W302M08 30x2x0,8 20, C6W402M08 40x2x0, C6W502M08 50x2x0, C6W602M08 60x2x0, C6W802M08 80x2x0,8 31, C6WAA2M08 100x2x0, Other dimensions and colours available on request. 192

202 TELEPHONE AND ELECTRONIC CABLES J-2Y(St)H Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: PE,type2Y Colour code: DIN VDE 0815 Stranding: conductors twisted to 5 quads,twisted to units Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: grey (RAL...), polymer compound flame retardant,halogen free, Features: St III Bd 16 Mbits/s (Kat.3) ISDN/EDV (Z = 100 Ohm) Nominal voltage: 300 V Test voltage: 800 V Min.Bending radius: fixed laying: 10 x d Temperature range: - 30 C / + 70 C - 5 C / + 70 C Resistance: Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part No.of pairs x Ø Outer-Ø ± 10% 50060C6W022M06 2x2x0,6 5, C6W042M06 4x2x0,6 9, C6W062M06 6x2x0,6 9, C6W082M06 8x2x0,6 9, C6W102M06 10x2x0,6 9, C6W202M06 20x2x0,6 12, C6W302M06 30x2x0, C6W402M06 40x2x0,6 16, C6W502M06 50x2x0,6 18, C6W602M06 60x2x0,6 20, C6W802M06 80x2x0, C6WAA2M06 100x2x0,6 25, Other dimensions and colours available on request. 193

203 TELEPHONE AND ELECTRONIC CABLES J-H(St)H installation cable Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: halogen-free compound type HI2,to DIN VDE part 23 Colour code: DIN VDE 0815 Stranding: cores twisted in quads, quads stranded to units. Wrapping: plastic tape Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: grey (RAL...),halogen free,type HM2 Features: Bd installation cable Nominal voltage: 300 V Test voltage: 800 V Min.Bending radius: fixed laying: 2,5 x d flexible application: 7,5 x d Radiation resistance: up to 100x10 6 cj/kg Temperature range: - 30 C / + 70 C - 5 C / + 70 C Resistance: Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part No.of pairs x Ø Outer-Ø ± 10% 50070C6W022M06 2x2x0,6 5, C6W042M06 4x2x0,6 8, C6W062M06 6x2x0, C6W102M06 10x2x0,6 10, C6W202M06 20x2x0,6 15, C6W302M06 30x2x0,6 16, C6W402M06 40x2x0,6 18, C6W502M06 50x2x0,6 20, C6W602M06 60x2x0,6 22, C6W802M06 80x2x0,6 26, C6WAA2M06 100x2x0,6 28, C6W022M08 2x2x0,8 6, C6W042M08 4x2x0,8 10, C6W062M08 6x2x0,8 10, C6W102M08 10x2x0,8 13, C6W202M08 20x2x0,8 20, C6W302M08 30x2x0,8 21, C6W402M08 40x2x0,8 24, C6W502M08 50x2x0,8 27, C6W602M08 60x2x0,8 29, C6W802M08 80x2x0,8 33, C6WAA2M08 100x2x0,8 37, Other dimensions and colours available on request. 194

204 TELEPHONE AND ELECTRONIC CABLES JE-Y(St)Y Bd Si industry-electronic cable acc.to DIN VDE 0815 Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: Special PVC,type YI3, to DIN VDE 0207 part.4 Colour code: DIN VDE 0815,(with ring colours and ring groups) Stranding: 2 core twisted in pair,4 pairs to a unit and several units stranded in layers (for 2 pairs cable,4 cores stranded to a quad) Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range fixed laying: flexible application: 300 V 2000 V 5 x d (fixed installation) up to 80x10 6 cj/kg - 30 o C to + 70 o C - 5 o C to + 50 o C Wrapping: Screen: plastic tape electrostatic screen of plastic and aluminium tape + tinned drain-wire Outer sheath: grey (RAL 7032) or blue (RAL 5015) special PVC type YM1 Features: Bd industry-electronic cable GREY: No.of pairs x Ø Outer-Ø ± 10% 50080C6W012M08 1x2x0, C6W022M08 2x2x0, C6W042M08 4x2x0, C6W082M08 8x2x0, C6W122M08 12x2x0, C6W162M08 16x2x0, C6W202M08 20x2x0, C6W322M08 32x2x0, C6W402M08 40x2x0, BLUE: No.of pairs x Ø Outer-Ø ± 10% 50080CBW012M08 1x2x0, CBW022M08 2x2x0, CBW042M08 4x2x0, CBW082M08 8x2x0, CBW122M08 12x2x0, CBW162M08 16x2x0, CBW202M08 20x2x0, CBW322M08 32x2x0, CBW402M08 40x2x0, Other dimensions and colours available on request. 195

205 TELEPHONE AND ELECTRONIC CABLES JE-LiYCY Bd Si industry-electronic cable acc.to DIN VDE 0815 Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: PVC,type YI3 Colour code: DIN VDE 0815,(with ring colours and ring groups) Stranding: 2 core twisted in pair,4 pairs to a unit and several units stranded in layers (for 2 pairs cable,4 cores stranded to a quad) Wrapping: plastic tape Screen: tinned copper braid coverage 85% Outer sheath: grey (RAL 7032) or blue (RAL 5015) special PVC type YM1 Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range fixed laying: flexible application: 300 V 2000 V 5 x d (fixed installlation) up to 80x10 6 cj/kg - 30 o C to + 70 o C - 5 o C to + 50 o C Features: Bd industry-electronic cable BLUE: No.of pairs x Ø Outer-Ø ± 10% 50090CBW022M05 2x2x0, CBW042M05 4x2x0, CBW082M05 8x2x0, CBW122M05 12x2x0, CBW202M05 20x2x0, CBW322M05 32x2x0, CBW402M05 40x2x0, GREY: No.of pairs x Ø Outer-Ø ± 10% 50090C6W022M05 2x2x0, C6W042M05 4x2x0, C6W082M05 8x2x0, C6W122M05 12x2x0, C6W202M05 20x2x0, C6W322M05 32x2x0, C6W402M05 40x2x0, Other dimensions and colours available on request. 196

206 TELEPHONE AND ELECTRONIC CABLES JE-LiHCH Conductor: Solid red copper conductor Cl. 1, acc to IEC Insulation: Halogen-free core insulation,type HI1 or HI2 to DIN VDE part 23, insulation wall thickness 0,3 mm. Colour code: DIN VDE 0815, (with ring colours and ring groups) Stranding: 2 core twisted in pair, 4 pairs to a unit and several units stranded in layers (for 2 pairs cable, 4 cores stranded to a quad). Wrapping: plastic tape. Screen: tinned copper braid coverage 85% Outer sheath: grey (RAL 7032) halogen-free, compound type HM1 or HM2 Features: Bd industry electronic cable Nominal voltage: Test voltage: Min.bending radius: Radiation resistance: Temperature range fixed laying: flexible application: Resistance: 300 V 2000 V 7,5 x d up to 100x10 cj/kg - 30 C to + 70 C - 5 C to + 50 C Flame retardant acc. to: IEC , EN , DIN VDE 0482 part Halogen free acc. to: EN ,IEC , DIN VDE 0482 part Low smoke emission acc. to: EN IEC , DIN VDE 0482 part Low corrosiveness combustion gases: EN , IEC ,DIN VDE 0482 part No.of pairs x Ø 2 Outer-Ø ± 10% 50100C6W022M05 2x2x0, C6W042M05 4x2x0, C6W082M05 8x2x0, C6W122M05 12x2x0, C6W202M05 20x2x0, C6W322M05 32x2x0, C6W402M05 40x2x0, Other dimensions and colours available on request. 197

207

208 INDUSTRIAL PLANT TECHNICAL DATA ELECTRIC RESISTAN SINGLE-CORE THREE-CORES nominal conductor 1.8/3 kv-3.6/6 kv 6/10 kv-8.7/15 kv mm 2 12/20 kv-15/20 kv-18/30 kv 26/45 kv 1.8/3 kv-6/10 kv-8.7/15 kv 12/20 kv-15/20 kv-18/30 kv 26/45 kv nominal conductor mm 2 1.8/3 kv-6/10 kv-8.7/15 kv 12/20 kv-15/20 kv-18/30 kv 26/45 kv CAPACITY VALUES AT 50 Hz nominal conductor screened armoured 6/10 kv 8.7/15 kv 12/20 kv 15/20 kv 15/20 kv 15/20 kv mm PHASE REACTAN VALUES AT 50 Hz SINGLE-CORE nominal conductor 1.8/3 kv 3.6/6 kv 6/10 kv 8.7/15 kv 12/20 kv 15/20 kv 18/30 kv 26/45 kv mm

209 INDUSTRIAL PLANT TECHNICAL DATA PHASE REACTAN VALUES AT 50 Hz SINGLE-CORE nominal conductor 1.8/3 kv 3.6/6 kv 6/10 kv 8.7/15 kv 12/20 kv 15/20 kv 18/30 kv 26/45 kv mm THREE-CORES PHASE REACTAN VALUES AT 50 Hz nominal conductor 1.8/3 kv 3.6/6 kv 6/10 kv 8,7/15 kv 12/20 kv 15/20 kv 18/30 kv 26/45 kv mm

210 INDUSTRIAL PLANT TECHNICAL DATA GROUP RATING FACTORS AMBIENT TEMPERATURE DIFFERENT FROM STANDARD CONDITIONS Ambient temperature C Ground laying cables Air cables THREE-CORE CABLES GROUNDED LAYING or single-core cables enclosed in trefoil Number of cables or trefoil-set (horizontally) Space between cables or trefoil-set cm cm THREE-CORE CABLES GROUNDED PIPE LAYING Number of cables (horizontally) THREE-CORE CABLES GROUNDED PIPE Number of cables (horizontally) Number of cables (vertically) Number of cables (horizontally) number of layer (vertically) Number of cables (vertically)

211 INDUSTRIAL PLANT TECHNICAL DATA SINGLE-CORE CABLE TREFOIL AIR LAYING Number of trefoil sets (horizontally) SINGLE-CORE CABLE TREFOIL AIR LAYING HORIZONTALLY AND VERTICALLY SPAD OUT Number of trefoil sets (horizontally) Number of cables (horizontally) Number of trefoil sets (horizontally) 1 2 number of layer (vertically) number of layer (vertically) PHASE LAY-OUT FOR SINGLE-CORE CABLES CONNECTED IN PARALLEL TO PROVIDE CORRECT CURRENT SPLITTING Trefoil laying cables Number of trefoil sets in the same layer Number of trefoil sets (vertically) 1 2 T RS T SR T T T RS SR SR T T T T RS SR RS SR Horizontally or vertically spaced out cables Number of trefoil sets in the same layer* 2 4 Number of trefoil sets (vertically) RST TSR RST TSR RST TSR When cables are installed on several layers their lay-out must be repeted for each year. SHORT CIRCUIT RATING The maximum short circuit current allowed for short period of time(few seconds) for copper or aluminium conductors can be calculated by the following formula: Where: Icc=short circuit current (A) K=factor of the conducting material which obtained from the difference between starting and final temperatur of short circuit; K copper= 143 K aluminium=92 S=area conductor (mm 2 ) t=duration of short circuit (sec) Material Conductor copper aluminium Icc= K.S (A) t To calculate the current allowed in the screen you can use the same formula indicated above for the conductor with the factor K = 180 C Starting material The following table reports the values in KA of the current calculated for the starting temperature of 90 C and for the duration of 1 second Area conductor mm 2 copper

212 INDUSTRIAL PLANT TECHNICAL DATA SHORT CIRCUIT RATING The voltage drop can be calculated by the following formula for connections in alternating current: Where: = voltage drop (V) K = 1,73 for three-phase system K = 2 for single phase system L = connecting lenght (km) I = current rating (A) R = conductor resistance at using temperature (Ohm/km) X = phase reactance (Ohm/km) cos = power factor For direct in current cos =1 Insulation rate Comparsion between rated voltages and insulation rate Nominal voltage kv Uo/U 1.8/3 3.6/6 6/10 8.7/15 12/20 15/20 18/30 26/45 Maximum voltage kv Um INSTALLATION Surveys show that all types of cables are damaged during installation because of carelessness, inexperience and lack of simple precautions. for the benefit of the many new workers, involved in electrical work and in the interesting of eliminating such preventable causes of electrical shutdown and loss of production, we suggest the following norms which govern the installation I Generation, transmission and distribuition systems of electric power cable i n stallation. We summarize some rules to be observed during the installation of cables for fixed l aying. Installation minimum temperature: 0 C referred to the cables so it s necessary to begin and finish the installation in suitable environmental conditions so that the cable temperature does not go below 0. radius: please see the values listed in range and dimension calculated according to I standards. Installation: it s advisable to apply the pool force, which is necessary to the installation, only to the conductors being careful not to exceeded kg/mm of total area conductor for copper cables and 5 kg/mm for aluminium cables. WOODEN DRUMS HANDLING NO YES NO YES Uo = relates to the nominal tension between a conductor on earth U = relates to the nominal tension between the conductors of the cable Um = maximum tension for which the cable is suitable FINAL TEST The final test to wich the Medium Voltage cables are subjected in compliance with I standards. Electrical test on: - high-voltage test - power factor measurement - electrical resistance of conductor and screen - insulation resistance measurement - partial decharge test (for tension Uo 6kV) Test on cable samples: - check of dimension - bending test - life test - impulsive withstand test - moisture resistance test Test on material samples: - tests for determining the mechanical properties of insulation before and after ageing - test for determining the mechanical the mechanical properties of sheaths before and after ageing - sheaths thermoplastic characteristics - charachteristics of wires, tapes, and steal flat wires of armouring (if possible) Electrical test after installations: before the final connection of equipments we recommende to carry out an high-voltage test to verify if the cables have benn damaged during the installation, in compliance with Insulation rated voltage Uo kv Electrical test after installations in c.c. for 15 kv

213 INDUSTRIAL PLANT TECHNICAL DATA Max. DC resistance at 20 C acc. to IEC Tinned conductors Cross-sectio Cl. 2 Ohm/km Cl. 5 Ohm/km Cross section mm 2 Cl. 2 Ohm/km Cl. 5 Ohm/km Plain conductor 1 18,2 20,0 70 0,270 0,277 1,5 12,2 13,7 95 0,195 0,210 2,5 7,56 8, ,154 0, ,70 5, ,126 0, ,11 3, ,100 0, ,84 1, ,0762 0, ,16 1, ,0607 0, ,734 0, ,0475 0, ,529 0, ,0396 0, ,391 0, ,0286 0,0292 Cross-sectio Cl. 2 Ohm/km Cl. 5 Ohm/km Cross section mm 2 Cl. 2 Ohm/km Cl. 5 Ohm/km 1 18,1 19,5 70 0,268 0,272 1,5 12,1 13,3 95 0,193 0,206 2,5 7,41 7, ,153 0, ,61 4, ,124 0, ,08 3, ,0991 0, ,83 1, ,0754 0, ,15 1, ,0601 0, ,727 0, ,0470 0, ,524 0, ,0366 0, ,387 0, ,0283 0,0287 Derating factors for various ambient air temperature acc. to IEC Temp cf. 1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,67 0,58 0,47 Short circuit current starting temperature 90 C, final temperature 250 C Cross-section x mm 2 1 sec. A 0,5 sec. A 0,2 sec. A Cross-section x mm 2 1 sec. A 0,5 sec. A 0,2 sec. A , ,

214 INDUSTRIAL PLANT TECHNICAL DATA Voltage drop (s up to 1 kv) 3x1 cores (trefoil formation) 2 cores 3-4 cores cross-section x mm2 C.d.T. c.a. Cosfi 1 mv/am C.d.T. c.a. Codfi 0,8 mv/am Instrumentation cables Max DC resistance 20 C acc. To IEC C.d.T. c.a. Cosfi 1 mv/am C.d.T. c.a. Codfi 0,8 mv/am C.d.T. c.a. Cosfi 1 mv/a m C.d.T. c.a. Codfi 0,8 mv/am 1 46,4 37,3 40,1 32,3 1,5 31,1 25,0 26,9 21,7 2,5 19,3 15,6 16,7 13,5 4 12,0 9,73 10,4 8,41 6 7,93 6,48 6,86 5,6 10 3,51 2,90 4,69 2,9 4,69 3, ,21 1,86 2,96 1,86 2,96 2, ,40 1,21 1,87 1,21 1,87 1, ,01 0,891 1,35 0,891 1,35 1, ,747 0,681 0,998 0,681 0,998 0, ,517 0,494 0,690 0,494 0,69 0, ,374 0,379 0,500 0,379 0,5 0, ,296 0,316 0,396 0,316 0,396 0, ,244 0,273 0,282 0, ,195 0,234 0,225 0, ,151 0,198 0,174 0, ,122 0,175 0,142 0,203 Tinned conductor Plain conductor cross-section x mm2 cl. 2 Ohm/km cl. 5 Ohm/km cl. 2 Ohm/km cl. 5 Ohm/km 0,75 26,3 28, ,6 1 19,3 21,2 19,2 20,7 1,5 12,9 14,5 12,8 14,1 2,5 8,02 8,71 7,56 8,47 205

215 INDUSTRIAL PLANT TECHNICAL DATA DIN DIN VDE NUMBER COLOR NUMBER COLOR 1 WHITE 32 YELLOW - blue 2 BROWN 33 GREEN - red 3 GREEN 34 YELLOW - red 4 YELLOW 35 GREEN - black 5 GRAY 36 YELLOW - black 6 PINK 37 GRAY - blue 7 BLUE 38 PINK - blue 8 RED 39 GRAY - red 9 BLACK 40 PINK - red 10 VIOLET 41 GRAY - black 11 GRAY - red 42 PINK - black 12 RED - blue 43 BLUE - black 13 WHITE - green 44 RED - black 14 BROWN - green 45 WHITE - brown - black 15 WHITE - yellow 46 YELLOW - green - black 16 YELLOW - brown 47 GRAY - pink - black 17 WHITE - gray 48 RED - blue - black 18 GRAY - brown 49 WHITE - green - black 19 WHITE - pink 50 BROWN - green- black 20 PINK - brown 51 WHITE - yellow - black 21 WHITE - blue 52 YELLOW - brown - black 22 BROWN - blue 53 WHITE - gray - black 23 WHITE - red 54 GRAY - brown - black 24 BROWN - red 55 WHITE - pink - black 25 WHITE - black 56 PINK - brown - black 26 BROWN - black 57 WHITE - blue - black 27 GRAY - green 58 BROWN - blue - black 28 YELLOW - gray 59 WHITE - red - black 29 PINK - green 60 BROWN- red - black 30 YELLOW - pink 31 GREEN - blue 61 BLACK - white Multicore flexible cables Number of cores Cores with green-yellow protective conductor (-J) Cores without green-yellow protective conductor (-O) 2 - blue-brown 3 green/yellow-blue-brown brown-black-grey 4 green/yellow-brown-black-grey blue-brown-black-grey 5 green/yellow-blue-brown-black-grey blue-brown-black-grey-black 6 green-yellow/black + white printed numbers black + white printed numbers Core identification with numbers acc. to EN Marking inscription for identification of cores of electric cables (number printing). Other core colours are allowed exept green and yellow. 206

216 INDUSTRIAL PLANT TECHNICAL DATA SINGLE WIRES COLOR IDENTIFICATION Core. no Basic color RAL 01 BLACK / NERO DARK BLUE / BLU SCURO (RAL 5010) BROWN / MARRONE GREY / GRIGIO YELLOW / GIALLO GREEN / VERDE VIOLET/ VIOLA WHITE / BIANCO ORANGE / ARANCIONE RED / ROSSO LIGHT BLUE / BLU CHIARO (RAL 5015) LIGHT BLUE / BLU CHIARO (RAL 5012) PINK / ROSA SKY BLUE/BLU SKY YELLOW-GREEN / GIALLO-VERDE 1021/ WHITE-DARK BLUE / BIANCO-BLU SCURO 9003/ DARK BLUE-WHITE / BLU-BIANCO 5010/ WHITE-GREY / BIANCO-GRIGIO 9003/ BLACK-GREEN / NERO-VERDE 9005/ BLACK-DARK BLUE / NERO-BLU SCURO 9005/ BLACK-WHITE / NERO-BIANCO 9005/ BLACK-VIOLET / NERO-VIOLA 9005/ BLACK-RED / NERO-ROSSO 9005/ WHITE-RED / BIANCO-ROSSO 9003/ WHITE-BROWN / BIANCO- MARRONE 9003/ DARK BLUE-RED / BLU SCURO-ROSSO 5010/ WHITE-VIOLET / BIANCO-VIOLA 9003/ WHITE-YELLOW / BIANCO-GIALLO 9003/ WHITE-GREEN / BIANCO-VERDE 9003/ WHITE-ORANGE / BIANCO-ARANCIONE 9003/ OFF WHITE GREY REDDISH BROWN BEIGE

217 INDUSTRIAL PLANT TECHNICAL DATA STRAND MAKE-UP ACCORDING TO DIN VDE 0295 and IEC Cross section mm 2 Stranded wires Class 2 DIN VDE 0295 Multi-stranded wires Fine wires Class 5 DIN VDE 0295 Class 6 DIN VDE 0295 Extra-fine wires Number of single wires x wire Ø mm Number of single wires x wire Ø mm Number of single wires x wire Ø mm Number of single wires x wire Ø mm Number of single wires x wire Ø mm Number of single wires x wire Ø mm Number of single wires x wire Ø mm 0,05 ~14x0,07 ~26x0,05 0,08 ~40x0,05 0,09 ~24x0,07 0,14 ~18x0,1 ~18x0,1 ~18x0,1 ~36x0,07 ~72x0,05 0,25 ~14x0,15 ~32x0,1 ~32x0,1 ~65x0,07 ~128x0,05 0,34 7x0,25 ~19x0,15 ~42x0,1 ~42x0,1 ~88x0,07 ~174x0,05 0,38 7x0,27 ~12x0,2 ~21x0,15 ~48x0,1 ~100x0,07 ~194x0,05 0,5 7x0,30 7x0,30 ~16x0,2 ~28x0,15 ~64x0,1 ~131x0,07 ~256x0,05 0,75 7x0,37 7x0,37 ~24x0,2 ~42x0,15 ~96x0,1 ~195x0,07 ~384x0,05 1,0 7x0,43 7x0,43 ~32x0,2 ~56x0,15 ~128x0,1 ~260x0,07 ~512x0,05 1,5 7x0,52 7x0,52 ~30x0,25 ~84x0,15 ~192x0,1 ~392x0,07 ~768x0,05 2,5 7x0,67 19x0,41 ~50x0,25 ~140x0,15 ~320x0,1 ~651x0,07 ~1280x0,05 4 7x0,85 19x0,52 ~56x0,3 ~224x0,15 ~512x0,1 ~1040x0,07 6 7x1,05 19x0,64 ~84x0,3 ~192x0,2 ~768x0,1 ~1560x0, x1,35 49x0,51 ~80x0,4 ~320x0,2 ~1280x0,1 ~2600x0, x1,70 49x0,65 ~128X0,4 ~512x0,2 ~2048x0,1 25 7x2,13 84x0,62 ~200x0,4 ~800x0,2 ~3200x0,1 35 7x2,52 133x0,58 ~280x0,4 ~1120x0, x1,83 133x0,69 ~400x0,4 ~705x0, x2,17 189x0,69 ~356x0,5 ~990x0, x2,52 259x0,69 ~485x0,5 ~1340x0, x2,03 336x0,67 ~614x0,5 ~1690x0, x2,27 392x0,69 ~765x0,5 ~2123x0, x2,52 494x0,69 ~944x0,5 1470x0, x2,24 627x0,70 ~1225x0,5 ~1905x0, x2,50 790x0,70 ~1530x0,5 ~2385x0, x2,89 ~2035x0, x3,23 ~1768x0, x2,97 ~2228x0,6 Permissible maximal diameter of single vires Nominal value Maximal value mm mm 0,2 0,21 0,25 0,26 0,3 0,31 0,4 0,41 0,5 0,51 0,6 0,61 208

218 INDUSTRIAL PLANT TECHNICAL DATA Conversion to mm 2 mm 2 mm 2 mm 2 mm , , kcmil , kcmil , , kcmil , , kcmil , / kcmil , / kcmil , /0 120 Units of Measurement Equivalence between metric size and -kcmil The US American standardization extracts several standardized section from 0,324 to 253 mm 2. Sections are designed by a gauge-number or a section in MCM (Mil Circular Mil). numbers are identical with the British Brown and Sharpe (B&S) numbers. 1 Mil = 0,0254 mm = 1/100 inch 1 MCM = 0,5067 mmq mm 2 mm 2 mm , , , , , , , , , , , , , , ,17 1/0 53, /0 67, /0 85, /0 107,2 Conversion from non-metric system - Measures of length Unit mils inch foot yard cm m 1 mils 1 0,001 0, , ,0025 0, inch ,0833 0, , foot , , yard , cm 393,7 0,3937 0,0328 0, ,01 1 m 39,37 39,37 3,281 1, ,

219 INDUSTRIAL PLANT TECHNICAL DATA FLAMABILITY TESTS FOR ELECTRICAL CABLES Examination of the vertical flame lenght, test method 1 kv - flame with gas/air mixture Description VDE 0482 part , EN and IEC Length of speciment 600 mm VDE 0482 part , EN and IEC mm Burner Test temperature Position of specimen Acc. to EN kw flame Vertical Acc. to VDE 0482 part and EN Defined by the stipulated setting of the Flame length Vertical Position of flame 45 to vertical specimen 45 to vertical specimen Duration of flame See table 1 20 seconds Conditions must be self-extinguishing. Thedamage or carbonization may only reach max. 50 mm under the upper fixing clamp. must be self-extinguishing. The damage or carbonization may only reach max. 10 mm under the upper fixing clamp. outer diameter *) of specimen in mm Nominal value outer diameter *) of specimen in mm D < D < D 240 D > *) If cables or insulated cables are tested that are not round (e.g. flat twin cables) their dimensions are to be measured and an equivalent diameter must be calculated from this. 210

220 INDUSTRIAL PLANT TECHNICAL DATA FLAMABILITY TESTS FOR ELECTRICAL CABLES Description UL 1581 section 1080 (VW-1 Flame test) Length of specimen Burner Test temperature Position of specimen Position of flame Duration of flame Conditions 455 mm Bunsen burner with additional air supply (Tirril-Gasburner) Ø 9,5 mm 500 W flame Vertical 20 to vertical specimen 5 x 15 seconds with 15 seconds between each flaming Paper max. 25% carbonized. The specimen may keep on burning for max. 1 minute after any application. Material dropping must not ignite the cotton (B) lying under the specimen. 211

221 INDUSTRIAL PLANT TECHNICAL DATA FLAMABILITY TESTS FOR ELECTRICAL CABLES Description UL 1581 section 1061 ( flame test) Length of specimen Burner Test temperature Position of specimen Position of flame Duration of flame Conditions 455 mm Bunsen burner with additional air supply (Tirril-Gasburner) Ø 9,5 mm 500 W flame Vertical 20 to vertical specimen 3 x 60 seconds with 30 seconds between each flaming Paper max. 25% carbonized. The specimen may keep on burning for max. 1 minute after any application. Material dropping must not ignite the cotton (B) lying under the specimen. 212

222 INDUSTRIAL PLANT TECHNICAL DATA FLAMABILITY TESTS FOR ELECTRICAL CABLES Description UL 1581 section 1060 (Vertical Flame and FT1 Test) Length of specimen Burner Test temperature Position of specimen Position of flame Duration of flame Conditions 455 mm Bunsen burner with additional air supply (Tirril-Gasburner) Ø 9,5 mm 500 W flame Vertical 20 to vertical specimen 5 x 15 seconds with 15 seconds between each flaming Paper max. 25% carbonized. The specimen may keep on burning for max. 1 minute after any application. 213

223 INDUSTRIAL PLANT TECHNICAL DATA FLAMABILITY TESTS FOR ELECTRICAL CABLES Description NF C C1 Length of specimen Test temperature Position of specimen Duration of test Conditions 455 mm 500 W flame Vertical 20 to vertical specimen 3 x 60 seconds with 30 seconds between each flaming 214

224 INDUSTRIAL PLANT TECHNICAL DATA Examination of the vertical flame length of vertical extended bundle of wires and insulated cables Description IEC , EN 50226, DIN VDE 0482 part. 266 Length of specimen Burner Test temperature Position of specimen Position of flame Duration of flame Conditions 3500 mm Flat burner (Ribbon gus burner of American Gas Furnace Co.) Defined by stipulated flow of gas and air Vertical Horizontal Category A, B: 40 minutes Category C, D: 20 minutes The burned portion of the sample must not be longer than 2,5 m measured from the bottom edge of the burner, as far as not otherwise specified in the relevant standards. EN IEC Category A-7 l/m 3/22 3/22 Category B-3,5 l/m 3/23 3/23 Category C-1,5 l/m > 12 mm cable-ø 3/24 3/24 Category D-0,5 l/m 12 mm cable-ø 3/25 3/25 Volume percent of non metallic material per meter 215

225 GAALSHOCK Technology TECHNICAL DATA GAALSHOCK Technology (GAALTHERM 600) CABLE SYSTEM GAALSHOCK Technology provides better mechanical protection than traditional metal armoured cable but almost the same of nonarmoured one. It is a complete new design with a layer of extruded plastic material, placed under the outer sheath, which absorbs the kinetic energy of an impact through plastic deformation. So the residual energy does not damage the sensitives parts of the cable, as insulation and screens. In fact metal armouring does not behave in the most efficient way, because part of the energy of a shock is transmitted to the inner layers of the cable, compromising the integrity of the insulation. In this way the level of protection achieved and the reliability are meaningful. In addition, the cable is lighter, more flexible and easier to be installed than of a traditional armoured cable. GAALSHOCK Technology can be applied to any type of cable, giving same advantages in terms of reliability and reduction of. PROTECTION AGAINST MECHANICAL DAMAGE The cables can be damaged in many different circumstances and in all operating environments. In civil works. During installation and excavation. In industrial sector Often mechanical abuse can damage the insulation and protective shields of the cable leading to a premature and unexpected failure and, in any case, to a dramatic decrease in long-term reliability. The Economic Consequences are inevitable, as well as the interruption in the continuity of Service. Normally the solution offered is to protect cables with a reinforced metal (applied in strips, wires, etc.) or to install cable in a protect environment, such as trays, tubes, etc. Both solutions involve significant cost and more time spent for the Installation. In detail, the classical metal armour offers a good protection, but, however, shows a significant disadvantage in terms of, flexibility and difficulties in junction compared to a standard not armoured cable. WORKING PRINCIPLE: GAALSHOCK Technology acts as a shock absorber. The plastic deformation of GAALTHERM 600 allows the dissipation of the impact energy through a greater deformation (i.e. more time), so with a specific low Strength (mv = Ft); in this way the potential damage to the inner layers of the cable is greatly reduced. In fact the metal armoured has a higher modulus, so the impact energy is dissipated with a low deformation and a high specific strength, and this is dangerous for the inner layers of the cable. ACSSORIES GAALSHOCK Technology is totally compatible with traditional junctions termination. The installation procedures are the same as for the traditional accessories. Standard Metal Armouring GAALSHOCK VERSION ADVANTAGES ARMOURING VERSION IN COMPARISON WHIT AN ARMOURED CABLE Better impact performance: +10% Lower diameter: -5% Lower : -30% length longer than the standard drums, more flexibility Same resistance to oils and chemicals Same resistance to the effects of water Installation and connection easier Low sensitivity to stray ground currents Replaces the traditional metal armour, with better performance on impact, and ease of installation. IN COMPARISON WHIT AN UNARMOURED CABLE Better impact performance: +100% Slightly larger diameter: +5% Slightly higher : +5% same flexibility Same fire performance Same resistance to oils and chemicals Same resistance to the effects of water same installation Provides a considerable improvement in the mechanical strength, with a slight increase in and rigidity. GAALSHOCK Technology SHEATH STEEL ARMOURING SHEATH GAALSHOCK Technology 216

226 GAALSHOCK Technology TECHNICAL DATA ADVANTAGES OF LAYING 1. Possibility to lay cables at about 90 cm depth (instead of 110 cm) in ground directly without using mechanical protection (as standards for armoured cables required), consequently saving work, saving of purchase and installation concerning the absence of external protection. 2. Possibility to fill the trench with the excavation material instead of sand, as normally prescribed. Sparing in this way transport, material and work costs. 3. Protection and preservation of integrity of the cable in the case of mechanical stress by absorbing the kinetic energy produced by the impact. 4. Save 15% on total average cost (Installation + cable) compared to standard cable. COMPARISON BETWEEN TWO SYSTEM INSTALLATION GAALSHOCK Technology system: Standard method: 1 excavator sand 3 workers resulting material 1 truck for laying the sand 2 excavators 1 truck 7 workers Trench with GAALSHOCK Technology: Standard Trench: 90 cm Resulting material 110 cm Resulting material Absence of external protection (acc. to I 20-17) External protection (acc. to I 20-17) Direct laying of the cable on the bottom of trench Sand 15 cm 30 cm 217

227 INDUSTRIAL PLANT TECHNICAL DATA Core identification for outdoor telephone cables according to VDE 0815 Type of stranding F star quad St star quad with phantom circuit St I star quad St III star quad TF star quad for carrier frequency PiMF pair in metal foil DIMF triple in metal foil VIMF quad in metal foil Stranding layout Lg stranding in layer Bd stranding in unit star quad 1)Colour coding for installation cables: J-Y(St)Y...Lg 2 pair cable: pair 1: a-red,b-black pair 2: a-white,b-yellow cables with more than 2 pairs Colour of the a-core in the first pair of each layer is red,in all other pairs it is white. The colour of the b-core is blue,yellow,green,brown, black in repeating order as follow: colour of b-core Number of pair blue yellow green brown black colour of b-core Number of pair blue yellow green brown black

228 INDUSTRIAL PLANT TECHNICAL DATA 2)Colour coding for installation cables: JE-Y(St)Y...Bd,JE-LiYCY...Bd JE-H(St)H...Bd,JE-LIHCH...Bd,RD-Y(St)Y,AJ-Y(St)YDY Bd Si 2 pair cable: pair 1: a-blue,b-red pair 2: a-grey,b-yellow cables with more than 2 pairs Colour of basic insulation of pairs in one bunch: pair core a b a b a b a b colour blue red grey yellow green brown white black For identification of bunches,cores are marked with black rings and bunches are wrapped by a colored tape. ring group 1 ring group 2 ring group 3 ring group 4 219

229 INDUSTRIAL PLANT TECHNICAL DATA Core identification for outdoor telephone cables according to VDE 0816 Five star-quads of each basic unit identification: Quad 1: basic insulation of all cores red Quad 2: basic insulation of all cores green Quad 3: basic insulation of all cores grey Quad 4: basic insulation of all cores yellow Quad 5: basic insulation of all cores white Single core are marked by rings: Identification of bunches: Bunch-N Colour rings for bunches of tape 4 cores 8 cores resp 4 pairs pink I I II II I II III IV orange I II III IV violet I II III IV pink I II III IV blue orange I II III IV red 220

230 INDUSTRIAL PLANT TECHNICAL DATA KTG Standard wooden/steel tyred wooden drums Drum Type Flange diameter D1 (mm) Barrel diameter D2 (mm) Overall width L1 (mm) Winding width L2 (mm) Maximum carrying capacity (kg) Standard wooden drum (kg) Steel-tyred wooden drum (kg)

231 222 Drum size and Drum type diameter mm diameter mm INDUSTRIAL PLANT TECHNICAL DATA drum barrel Ø 40 x D drum barrel Ø 25 x D drum barrel Ø 15 x D drum barrel Ø 15 x D drum barrel Ø 50 x D

232 Note:

233 224

Industrial Oil And Gas

Industrial Oil And Gas Industrial Oil And Gas Elettrotek Kabel was born in Italy at the end of 2001 with the aim of supply electrical cables for special applications in various sectors, particularly for industrial automation.

More information

Kabel CONNECTION. A partnership to your advantage.

Kabel CONNECTION. A partnership to your advantage. Kabel THE CABLE CONNECTION catalogue www.boehm-kabel.de A partnership to your advantage Four reasons......to choose Kabel We can supply to final consumers if you express the wish. Fast and reliable supply

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

FTG10M1-0,6/1 kv FTG10OM1-0,6/1 kv

FTG10M1-0,6/1 kv FTG10OM1-0,6/1 kv Low voltage - Energy, signalling and control FTG10M1-0,6/1 kv FTG10OM1-0,6/1 kv Fire Structure and, physical, mechanical requirements: CEI 20-45 Fire propagion: EN 60332-3-24 (CEI 20-22 III) Flame propagion:

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

Who we are. Elettrotek Kabel was founded in 2001 in Bagnolo in Piano, Italy.

Who we are. Elettrotek Kabel was founded in 2001 in Bagnolo in Piano, Italy. Port & Cranes Elettrotek Kabel was founded in 2001 in Bagnolo in Piano, Italy. We are able to supply our products and our attention on different sectors, such as automation, port, steel, mining, marine

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

WHO WE ARE. We are able to supply our products and our attention on different sectors, such as automation, port, steel, mining, marine and oil & gas

WHO WE ARE. We are able to supply our products and our attention on different sectors, such as automation, port, steel, mining, marine and oil & gas Port & Cranes Elettrotek Kabel was founded in 2001 in Bagnolo in Piano, Italy. We are able to supply our products and our attention on different sectors, such as automation, port, steel, mining, marine

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Approvals (Norm references)

Approvals (Norm references) ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

CATALOGUE CATALOGUE WE ALWAYS HAVE SOMETHING IN STORE.

CATALOGUE CATALOGUE WE ALWAYS HAVE SOMETHING IN STORE. CATALOGUE CATALOGUE WE ALWAYS HAVE SOMETHING IN STORE. YOUR CONTACT WITH US: Phone +49 681 9711-0 Fax +49 681 9711-289 info@faberkabel.de You can find further useful information such as, for example, our

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

THERMOCOUPLE CABLES THERMOELECTRICITY

THERMOCOUPLE CABLES THERMOELECTRICITY THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Solar Cable www.bericacavi.com www.fctsecuritycables.com SOLAR CABLE TINNED COPPER Outer sheath Insulation Conductor Conductors: fine wires stranded of tinned copper Cl. 5 CEI EN 60228 Insulation: 2Pfg

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

Industrial Ethernet Cables

Industrial Ethernet Cables Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Medium voltage - Energy RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Structure and electrical, physical, mechanical requirements: CEI 20-13 IEC 60502 Flame propagation: EN 60332-1-2 Measurement of partial

More information

Cable systems We offer you the essential components for a future-oriented e-mobility.

Cable systems We offer you the essential components for a future-oriented e-mobility. Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation

More information

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for

More information

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description. H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod

Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod Z V ET L I Т Traditional reliability Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod www.zvetlit.ru Contents 1 About company 2 Analogues (according to IEC, VDE, PN, HD, BS) 4 Power

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable ()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr For

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

Industrial Cables and Wires

Industrial Cables and Wires HELUKABEL Products are available from MARYLAND METRICS P.O. Box Owings Mills, MD USA web: http://mdmetric.com ph: ()35-330 (00)3-30 fx: ()35-3 (00)7-939 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

Technical attributes

Technical attributes Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Single Core Cables 51

Single Core Cables 51 Single Core Cables 51 Single Core Cables PVC PVC Single Core Cables H05V-K /H07V-K Conductors: Flexible copper (class 5) Insulation: PVC Standards: HAR CENELEC Fire Performance: Flame retardant to IEC

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 REELING CABLE RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 Contents: Letter code Construction details and voltage-classes Technical data 2016 RHEYFIRM(RTS)

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

Our annual production capacity is 3000 tons for copper and 4000 tons for PVC.

Our annual production capacity is 3000 tons for copper and 4000 tons for PVC. Elki Cable is one of Turkey's leading companies in its sector and produces cables in accordance with international quality standards. Elki Cable has been founded in 983 and since 986, it has been producing

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

Data sheet chainflex CF6

Data sheet chainflex CF6 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture

More information

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to

More information

H05 V-K PVC-Single Cores, fine wire stranded

H05 V-K PVC-Single Cores, fine wire stranded H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation

More information

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands Lapp Kabel, power and control cable, PVC single core for field wiring, UL MTW VW-1, UL AWM style

More information

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics ENERGY TECSUN(PV) PV1-F Cables for Photovoltaics Technical Data Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / Germany TECSUN (PV) PV1-F Approvals

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date Last Amended on - Page 1 of 6 I. CABLES AND ACCESSORIES 1. PVC Insulated Cables Tests on Conductor: Annealing Test (copper) IS 10810 (Part 1):1984 (RA 2011) 0 to 50 % Tensile Test (Aluminium) IS 10810

More information

Industry Cables Special cables for industrial applications General Catalogue

Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General catalogue Linking the Future As the worldwide leader in the

More information

Item Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE...

Item Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE... Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter Halogen-free single A A 146 FRN A A 156 FRN Halogen-free single conductor with improved fire performance and extended

More information

Caledonian Flame Retardant RS485 Databus Cables

Caledonian Flame Retardant RS485 Databus Cables Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire PVC

More information

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics ENERGY TECSUN(PV) PV1 F Cables for Photovoltaics Technical Data Electrical Thermal Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / DE TECSUN (PV)

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

H07RN-F TITANEX PREMIUM

H07RN-F TITANEX PREMIUM New generation of flexible cables elastomer H07RN-F, born to release you from all the constraints. Thanks to its specific technology, it includes the properties of H07RN8-F; H07BN4-F; H07BB-F. Description

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

Cables for Airport Equipment

Cables for Airport Equipment Cables for Airport Euipment BB 380 Boarding Bridge www.sab-worldwide.com Content The Company............................................................................................................

More information