CATALOGUE CATALOGUE WE ALWAYS HAVE SOMETHING IN STORE.

Size: px
Start display at page:

Download "CATALOGUE CATALOGUE WE ALWAYS HAVE SOMETHING IN STORE."

Transcription

1 CATALOGUE CATALOGUE WE ALWAYS HAVE SOMETHING IN STORE.

2 YOUR CONTACT WITH US: Phone Fax You can find further useful information such as, for example, our image film, a metal course archive or our download area at Klaus Faber AG 2017 Please note: Not all the products and designs listed in this catalogue are in stock at all times. Subject to modifications in the sense of technical progress, and errors excepted. We assume no liability for printing errors. All the product images included here serve for illustration only and may not correspond to the actual products. The contributions and pictures may only be reused with the explicit approval of Klaus Faber AG. Version: 11/2017

3 POWER LOW VOLTAGE / MEDIUM VOLTAGE / OVERHEAD LINES 15 POWER SHEATHED 63 SINGLE CORES / INSULATED CORDS / SPEAKER / RUBBER INSULATED / PUR-INSULATED / SILICONE INSULATED / SPECIAL / TRAILING 69 S INSTALLATION / SUBSCRIBER LINE / INSTRUMENTATION / INDUSTRIAL ELECTRONICS / PVC-INSULATED 117 CONTENT ELECTRONIC CONTROL / ELECTRONIC / BUS / DRAG CHAIN / SPECIAL E30 OR E90 POWER WITH / COMMUNICATION WITH LAN 100-MHZ / 200-MHZ / 1000-MHZ ELECTRONIC LAN COAXIAL RG-TYPES / SAT / CATV 217 COAXIAL - OUTDOOR / - INDOOR / MULTI-PURPOSE 221 COPPER CONDUCTORS / COMPENSATION 229 TYPE DESIGNATION CODE FOR / CORE IDENTIFICATION / COLOUR CODING OF CORES / SELECTION HELP FOR DRAG CHAIN / PROPERTIES OF INSULATING & SHEATH MATERIALS / SIZES OF CABLE DRUMS / LEGEND OF ICONS / ABBREVIATIONS FOR COLOURS / TYPE INDEX / ARTICLE INDEX / PAYMENT AND DELIVERY CONDITIONS 235

4 HIGH PRODUCT AVAILABILITY MEETS STRONG RANGE. Product availability and product variety are the foundations of our business concept. Our product portfolio with up to items makes our cable and wire range one of the largest in Europe. We keep a goods volume of approximately 100 million euros available in 148,000 m2. This way we can considerably minimize the risk for our clients because our just-in-time delivery offers the best protection from theft. Plus the fact that our business partners don t need to coit any capital, thanks to our inventory. Our performance spectrum meanwhile ranges from high voltage cables via data lines through to special cables. We deliver our products around the world from two logistics locations in Germany, in the cross-sections and lengths you require. up to 17,000 ITEMS in our product portfolio We combine internationality in an ideal manner with the flat hierarchies and short distances of a dynamic and personally managed medium-size company the best conditions for constant top performance. We garner top marks in the supplier ratings of our clients for our on-time delivery and adherence to schedules, and are regarded as an A-supplier in the industry.

5 100 MIO Volume of goods m 2 area You can meanwhile not only rely on ourselves, but also on our products. Our brand FABER not only stands for an unfailingly good product quality, but also for excellent service. Which, besides the product availability, also includes a steady delivery performance as well as competent and comprehensive advice. We ensure our high quality standard by way of regular and intensive quality controls. Our own companies and partner factories are all ISO 9001-certified. The standard models for the German market are VDE-approved, of course. In addition to this, many of our products have been internationally certified as per UL, CSA or EAC. We hope you will enjoy browsing through this. And please get in touch with any questions you may have. We would be delighted to help you. YOUR FABER-TEAM

6 MANY INDUSTRIES. ONE MISSION. A great number of renowned companies in a broad variety of industries put their trust in us around the world. Rely on us. We know the ropes. ELECTRICAL WHOLESALERS MECHANICAL AND PLANT ENGINEERING ENERGY INDUSTRY We have been successfully established in the market for almost 50 years now, and know that every industry has its own unique characteristics and individual requirements. We have been able to prove our know-how and skills in a great number of projects already.

7 CONSTRUCTION INDUSTRY TRANSPORT AND TRAFFIC COMPUTING SPECIAL We will always find a custom-fit solution for our customers. These can be tried-and-tested solutions, but also concepts you might not have even thought of. The possibilities are virtually unlimited, thanks to our comprehensive product portfolio. On top of that we also offer you on-time delivery, competitive prices and an outstanding customer service also in technical matters. You can find a selection of our reference clients on our website.

8 WE HAVE THE BEST CONNECTIONS. OUR PREASSEMBLED. Be it for cranes, concrete mixers or construction machinery you can have cables with a wire cross-section of 16 to 240 ² (and up to 300 ² with single-core cables) preassembled by us in small batches, using high-quality cable lugs, ferrules, couplings and plugs from renowned manufacturers. The type of preassembly is meanwhile individually tailored to the customer s wishes. A final inspection of the preassembled cables guarantees consistent quality.

9 OUR CABLE PRINTING SERVICE. Are you in need of individual labelling for your products that is wind- and weatherproof and offers effective protection from theft or mix-ups? No problem. We will turn your cables and wires into unique specimens with our printing service. Printable are all cables and wires from a cross-section of 3 x 1.5 2, and that from a minimum purchase volume of no more than 5 meters. YOU ARE UNIQUE.

10 STRONG TEAM. STRONG SERVICE. Service means seeing the business with the eyes of the customer. Which is why our entire company and every one of its employees strive to consistently align our proposals and services with the customers wishes. We therefore consider it meaningful for you to have a dedicated consultant in our company who knows you and is aware of your priorities in orders and deliveries. Because we want satisfied customers who, in a best-case scenario, will also become ambassadors of their and our favourite brand: FABER.

11 ACTIONS SPEAK LOUDER THAN WORDS. We will supply you from stock with cables and wires in nearly all cross-sections and individual lengths virtually anywhere in the world. We will take care of your concerns regardless of whether you need special air freight packaging, ISPM 15 heat treatment or export management in the Atlas process. We can offer you a great variety of transport solutions all according to your needs. We are there when time is of the essence. We stick to exact delivery dates or enable collection by you as the customer. We do our utmost to satisfy you in every case.

12 DIGITAL THROUGH AND THROUGH. OUR E-SERVICES. Benefit from our digital services. Our company is networked with various online information and data exchange systems that will conveniently and comprehensively provide you with information on prices, availabilities and a lot more besides. Our web services ELGATE and GeDa-X enable you to access inventory information online. Our product master data and latest price information are available in different standard formats. Catalogues and brochures can be found at our OXOMI platform for browsing or download. Our range of e-services is rounded off by the data provision at EPLAN. We not only set new standards, but also consistently increase our service quality. If you are interested in our e-services, please get in touch with your contact person for internal and external field service or directly with our master data management.

13 WE GO STRICTLY NEW WAYS AND PROTECT TO OURSELVES WITH IT OUR SERVICE STRENGTH. ALWAYS IN THE INTEREST OF OR CUSTOMERS.

14 NOTES COAXIAL LAN ELECTRONIC POWER 14

15 LOW VOLTAGE 16 NYY-J 16 NYY-O 18 NYY-JZ 19 NYY-OZ 20 NAYY-J 21 NAYY-O 22 NYCWY 23 NYCY 24 NAYCWY 25 (N)Y(Zg)2Y 26 NYFGY 3.6/6 kv 27 N2XH-J 28 POWER POWER N2XH-O 30 N2XCH 31 N2XH-J (B2ca) 32 N2XH-O (B2ca) 34 N2XCH (B2ca) 35 (N)YYoek-J 36 NA2X2Y-J 36 NA2XY-J 37 NAY2Y-J 38 ELECTRONIC MEDIUM VOLTAGE 39 N2XSY 6/10 kv 39 N2XSY 12/20 kv 40 N2XSY 18/30 kv 41 NA2XSY 6/10 kv 42 NA2XSY 12/20 kv 43 NA2XSY 18/30 kv 44 N2XS2Y 6/10 kv 45 N2XS2Y 12/20 kv 46 N2XS2Y 18/30 kv 47 NA2XS2Y 6/10 kv 48 NA2XS2Y 12/20 kv 49 NA2XS2Y 18/30 kv 50 N2XS(F)2Y 6/10 kv 51 N2XS(F)2Y 12/20 kv 52 N2XS(F)2Y 18/30 kv 53 NA2XS(F)2Y 6/10 kv 54 NA2XS(F)2Y 12/20 kv 55 NA2XS(F)2Y 18/30 kv 56 N2XS(FL)2Y 6/10 kv 57 N2XS(FL)2Y 12/20 kv 57 NA2XS(FL)2Y 6/10 kv 58 NA2XS(FL)2Y 12/20 kv 59 NA2XS(FL)2Y 18/30 kv 59 N2XSEY 6/10 kv 60 LAN COAXIAL OVERHEAD LINES 61 NFA2X 61

16 POWER / LOW VOLTAGE POWER NYY-J ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca Standard VDE bare copper class 1, from 25 sq class 2 PVC DIV 4 PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X300 RMv SW X400 RMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW X400 SMv SW X16/10 RE SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW

17 NYY-J LOW VOLTAGE / POWER X300/150 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X10 RM SW X16 RE SW X16 RM SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW X300 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X10 RM SW X16 RE SW X16 RM SW X25 RM SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW ELECTRONIC COAXIAL LAN POWER 17

18 POWER / LOW VOLTAGE POWER NYY-O ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca Standard VDE bare copper class 1, from 25 sq class 2 PVC DIV 4 PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X300 RMv SW X400 RMv SW X500 RMv SW X630 RMv SW X800 RMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW

19 NYY-O LOW VOLTAGE / POWER POWER NYY-JZ X185 SMv SW X240 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW CPR-performance acc. to EN Eca Standard VDE bare copper class 1 = solid PVC DIV 4 PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW ELECTRONIC LAN COAXIAL

20 POWER POWER / LOW VOLTAGE NYY-JZ NYY-OZ X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X6 RE SW X6 RE SW X10 RE SW ELECTRONIC LAN CPR-performance acc. to EN Eca Standard VDE bare copper class 1 = solid PVC DIV 4 PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete. COAXIAL X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW

21 NYY-OZ LOW VOLTAGE / POWER POWER X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW X4 RE SW NAYY-J CPR-performance acc. to EN Eca Standard VDE aluminium PVC DIV 4 PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Nominal voltage Uo 600 V Item number Item name Colour Al. weight Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete X16 RE SW X25 RE SW X35 RE SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X300 RMv SW X400 RMv SW X500 RMv SW X630 RMv SW X800 RMv SW X16 RE SW X25 RE SW X35 RE SW X50 SE SW X70 SE SW X95 SE SW X120 SE SW X150 SE SW X185 SE SW X240 SE SW ELECTRONIC LAN COAXIAL

22 POWER POWER / LOW VOLTAGE NAYY-J Item number Item name Colour Al. weight X300 SE SW X10 RE SW X16 RE SW X25 RE SW X25 RM SW X35 RE SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW X300 SMv SW ELECTRONIC NAYY-O LAN COAXIAL CPR-performance acc. to EN Eca Standard VDE aluminium PVC DIV 4 PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Nominal voltage Uo 600 V Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete. Item number Item name Colour Al. weight X16 RE SW X25 RE SW X35 RE SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X300 RMv SW X400 RMv SW X500 RMv SW

23 NAYY-O LOW VOLTAGE / POWER Item number Item name Colour Al. weight POWER X630 RMv SW X800 RMv SW X16 RE SW X25 RE SW X35 RE SW X50 SE SW X70 SE SW X95 SE SW X120 SE SW X150 SE SW X185 SE SW X240 SE SW NYCWY CPR-performance acc. to EN Eca Standard VDE bare copper class 1, from 25 sq class 2 PVC DIV 4 Concentric conductor Cu PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete X95/50 RM SW X240/120 RM SW X10/10 RE SW X16/16 RE SW X25/16 RM SW X25/25 RM SW X50/25 RM SW X10/10 RE SW X16/16 RE SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X25/25 RM SW X35/35 SM SW X50/50 SMv SW X70/70 SMv SW X95/95 SMv SW X120/120 SMv SW X150/150 SMv SW ELECTRONIC LAN COAXIAL

24 POWER POWER / LOW VOLTAGE NYCWY X300/150 SMv SW X10/10 RE SW X16/16 RE SW X16/16 RM SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X300/150 SMv SW NYCY ELECTRONIC LAN CPR-performance acc. to EN Eca Standard VDE bare copper class 1, from 25 sq class 2 PVC DIV 4 Concentric conductor Cu PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete. COAXIAL X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X1.5/1.5 RE SW X2.5/2.5 RE SW X2.5/10 RE SW X4/4 RE SW X6/6 RE SW X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X1.5/2.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X1.5/2.5 RE SW X2.5/4 RE SW

25 NYCY LOW VOLTAGE / POWER POWER NAYCWY X4/6 RE SW X1.5/2.5 RE SW X2.5/4 RE SW X4/6 RE SW X1.5/2.5 RE SW X2.5/6 RE SW X1.5/4 RE SW X2.5/6 RE SW X1.5/4 RE SW X2.5/6 RE SW X1.5/6 RE SW X1.5/6 RE SW X2.5/10 RE SW X1.5/6 RE SW X2.5/10 RE SW X1.5/10 RE SW X2.5/10 RE SW X1.5/10 RE SW CPR-performance acc. to EN Eca Standard VDE aluminium PVC DIV 4 Concentric conductor Cu PVC DMV 5 Colour outer sheath black VDE /IEC UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Item number Item name Colour Cop. weight Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete. Al. weight X16/16 RE SW X25/16 RE SW X35/16 RE SW X50/25 RE SW X50/25 SE SW X70/35 SE SW X95/50 SE SW X120/70 SE SW X150/70 SE SW X185/95 SE SW X240/120 SMv SW X300/150 SMv SW ELECTRONIC LAN COAXIAL 25

26 POWER POWER / LOW VOLTAGE (N)Y(Zg)2Y COAXIAL ELECTRONIC LAN bare copper Application: class 1 = solid PVC DIV 4 Strength member Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo Nominal voltage U Core identification in outer sheath embedded glass yarns polyethylene 2YM1 70 C C 5-70 C 10 x DA 600 V 1000 V colours acc. to VDE 0293 (HD308) The cable is designed for selfsupporting aerial outdoor installation to support distances of up to 50 m. Suitable for supplying thinly populated or hard-to-reach areas, provisional building sites or for bridging difficult terrain. The hightensile cable sheath can be regarded as a pulling aid so that the cable can also be pulled into pipes over long distances (gas and water pipelines) X1.5 RE SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X10 RE SW X16 RE SW X16 RE SW

27 NYFGY 3.6/6 kv LOW VOLTAGE / POWER ELECTRONIC COAXIAL LAN POWER Standard VDE 0271 Application: bare copper class 1, from 25 sq class 2 PVC YI4 Material inner sheath PVC Armour flat steel wire, galvanized PVC YM3 VDE /IEC Maximum permitted conductor temperature 70 C C Bending radius, fixed installation 15 x DA Nominal voltage Uo 3600 V As distribution cable for industrial plants and switching boxes. For fixed installation indoors, direct burial in the ground, in water as well as in concrete and for heavy duty mechanical load X35 SM RT X50 SMv RT X70 SMv RT X95 SMv RT X120 SMv RT X150 SMv RT X185 SMv RT X240 SMv RT

28 POWER / LOW VOLTAGE POWER N2XH-J ELECTRONIC LAN COAXIAL CPR-performance acc. to EN on request Standard VDE bare copper class 1, from 25 sq class 2 XLPE 2XI1 FRNC-compound HM4 DIN EN /VDE /IEC (cat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Application: Zero-halogen, low-smoke power cable with improved flame-retardance. For fixed installation indoors, in air as well as in concrete, but not for direct burial in the ground or application in water /en/ X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW X300 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW

29 N2XH-J LOW VOLTAGE / POWER X25 RM SW X35 RM SW X50 RMv SW X1.5 RE SW X6 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X4 RE SW X4 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RMv SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW ELECTRONIC COAXIAL LAN POWER 29

30 POWER / LOW VOLTAGE POWER N2XH-O ELECTRONIC LAN COAXIAL CPR-performance acc. to EN on request Standard VDE bare copper class 1, from 25 sq class 2 XLPE 2XI1 FRNC-compound HM4 DIN EN /VDE /IEC (cat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Application: Zero-halogen, low-smoke power cable with improved flame-retardance. For fixed installation indoors, in air as well as in concrete, but not for direct burial in the ground or application in water X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X300 RMv SW X400 RMv SW X500 RMv SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW

31 N2XCH LOW VOLTAGE / POWER POWER CPR-performance acc. to EN on request Standard VDE bare copper class 1, from 25 sq class 2 XLPE 2XI1 Concentric conductor Cu FRNC-compound HM4 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C C Application: Zero-halogen, low-smoke power cable with improved flame-retardance. For fixed installation indoors, in air as well as in concrete, but not for direct burial in the ground or application in water X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X10/10 RE SW X16/16 RE SW X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X10/10 RE SW X16/16 RE SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X10/10 RE SW X16/16 RE SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X1.5/1.5 RE SW X1.5/2.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X2.5/4 RE SW ELECTRONIC LAN COAXIAL

32 POWER POWER / LOW VOLTAGE N2XCH X1.5/2.5 RE SW X2.5/4 RE SW X4/6 RE SW X1.5/2.5 RE SW X2.5/6 RE SW X2.5/10 RE SW X1.5/6 RE SW X2.5/10 RE SW X1.5/6 RE SW X2.5/6 RE SW X2.5/10 RE SW N2XH-J (B2ca) ELECTRONIC LAN COAXIAL CPR-performance acc. to EN B2ca Standard VDE bare copper class 1, from 25 sq class 2 XLPE 2XI1 FRNC-compound HM4 DIN EN /VDE /IEC (cat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C temperature, in motion/ C during installation Bending radius, fixed installation 15 x DA Application: Low-smoke, zero-halogen, flameretardant power cable. For fixed indoor installation as well as in concrete, but not for direct burial in ground or application in water /en/ X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X35 SM SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW

33 N2XH-J (B2ca) LOW VOLTAGE / POWER POWER X70 SMv SW X95 SMv SW X120 SMv SW X150 SMv SW X185 SMv SW X240 SMv SW X1.5 RE SW X2.5 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X1.5 RE SW X6 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X2.5 RE SW X4 RE SW X4 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW ELECTRONIC LAN COAXIAL 33

34 POWER POWER / LOW VOLTAGE N2XH-O (B2ca) ELECTRONIC LAN COAXIAL CPR-performance acc. to EN B2ca Standard VDE bare copper class 1, from 25 sq class 2 XLPE 2XI1 FRNC-compound HM4 DIN EN /VDE /IEC (cat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C temperature, in motion/ C during installation Bending radius, fixed installation 15 x DA Application: Low-smoke, zero-halogen, flameretardant power cable. For fixed indoor installation as well as in concrete, but not for direct burial in ground or application in water X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 RM SW X50 RMv SW X70 RMv SW X95 RMv SW X120 RMv SW X150 RMv SW X185 RMv SW X240 RMv SW X300 RMv SW X400 RMv SW X500 RMv SW X1.5 RE SW X1.5 RE SW X2.5 RE SW X4 RE SW X10 RE SW X4 RE SW X6 RE SW X10 RE SW X16 RE SW X25 RM SW X35 SM SW X50 SMv SW X70 SMv SW X95 SMv SW

35 N2XCH (B2ca) LOW VOLTAGE / POWER POWER CPR-performance acc. to EN B2ca Standard VDE bare copper class 1, from 25 sq class 2 XLPE 2XI1 Concentric conductor Cu FRNC-compound HM4 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C C ELECTRONIC LAN COAXIAL Application: Low-smoke, zero-halogen, flameretardant power cable. For fixed indoor installation as well as in concrete, but not for direct burial in ground or application in water X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X10/10 RE SW X16/16 RE SW X25/16 RM SW X50/25 SMv SW X185/95 SMv SW X1.5/1.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X10/10 RE SW X16/16 RE SW X25/16 RM SW X35/16 SM SW X50/25 SMv SW X70/35 SMv SW X95/50 SMv SW X120/70 SMv SW X150/70 SMv SW X185/95 SMv SW X240/120 SMv SW X1.5/2.5 RE SW X2.5/2.5 RE SW X4/4 RE SW X6/6 RE SW X1.5/2.5 RE SW X2.5/4 RE SW X1.5/6 RE SW

36 POWER POWER / LOW VOLTAGE (N)YYoek-J bare copper Application: PVC YI4 PVC YM3 Maximum permitted conductor temperature temperature, in motion/ during installation Nominal voltage Uo Nominal voltage U VDE /IEC C 70 C C 600 V 1000 V For fixed installation indoors and outdoors, also for direct burial in the the ground. Preferably for power supply and control of oil and fuel pumps, dispensing pumps and similar systems. The resistance to oil and fuel is proofed by BAM-test report VI. 34/10389/96 and tests according to VDE 0472 p. 803, test B. (BAM = Federal Institute for Materials Research and Testing) ELECTRONIC X1.5 RE SW X1.5 RE SW X1.5 RE SW NA2X2Y-J LAN COAXIAL Standard VDE Application: aluminium For fixed installation indoors, outdoors, in the ground, in water and XLPE in conrete. polyethylene Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature 90 C C Bending radius, fixed installation 15 x DA Nominal voltage Uo 600 V Nominal voltage U 1000 V Item number Item name Colour Al. weight X16 RE SW X25 RE SW X35 RE SW X50 SE SW X70 SE SW

37 NA2X2Y-J LOW VOLTAGE / POWER Item number Item name Colour Al. weight POWER X95 SE SW X120 SE SW X150 SE SW X185 SE SW X240 SE SW NA2XY-J CPR-performance acc. to EN Eca Standard VDE aluminium XLPE DIX3 PVC DMV6 Colour outer sheath black VDE /IEC Maximum permitted conductor temperature 90 C 90 C temperature, in motion/ C during installation Bending radius, fixed installation 15 x DA Nominal voltage Uo 600 V ELECTRONIC LAN COAXIAL Application: For fixed installation indoors, outdoors, in the ground, in water and in conrete. Item number Item name Colour Al. weight X16 RE SW X25 RE SW X35 RE SW X50 SE SW X70 SE SW X95 SE SW X120 SE SW X150 SE SW X185 SE SW X240 SE SW X300 SMv SW

38 POWER POWER / LOW VOLTAGE NAY2Y-J ELECTRONIC COAXIAL LAN Standard VDE Application: aluminium For fixed installation indoors, outdoors, in the ground, in water and PVC in conrete. polyethylene DMP2 Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature 70 C 70 C temperature, in motion/ C during installation Bending radius, fixed installation 12 x DA Nominal voltage Uo 600 V Item number Item name Colour Al. weight X35 RE SW X50 SE SW X70 SE SW X95 SE SW X120 SE SW X150 SE SW X185 SE SW X240 SE SW

39 N2XSY 6/10 kv MEDIUM VOLTAGE / POWER POWER COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo ELECTRONIC LAN VDE /IEC C 70 C C 15 x DA 6000 V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE cables must be protected from sunlight X35/16 RM RT X50/16 RMv RT X70/16 RMv RT X95/16 RMv RT X120/16 RMv RT X150/16 RMv RT X150/25 RMv RT X185/16 RMv RT X185/25 RMv RT X240/16 RMv RT X240/25 RMv RT X300/25 RMv RT X400/35 RMv RT X500/35 RMv RT X630/35 RMv RT

40 POWER POWER / MEDIUM VOLTAGE N2XSY 12/20 kv ELECTRONIC LAN COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo VDE /IEC C 70 C C 15 x DA V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE cables must be protected from sunlight X35/16 RM RT X50/16 RMv RT X70/16 RMv RT X95/16 RMv RT X120/16 RMv RT X150/16 RMv RT X150/25 RMv RT X185/16 RMv RT X185/25 RMv RT X240/16 RMv RT X240/25 RMv RT X300/25 RMv RT X400/35 RMv RT X500/35 RMv RT X630/35 RMv RT X800/50 RMv RT X800/35 RMv RT

41 N2XSY 18/30 kv MEDIUM VOLTAGE / POWER POWER COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo ELECTRONIC LAN VDE /IEC C 70 C C 15 x DA V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE cables must be protected from sunlight X35/16 RM RT X50/16 RMv RT X70/16 RMv RT X95/16 RMv RT X120/16 RMv RT X150/25 RMv RT X185/25 RMv RT X240/25 RMv RT X300/25 RMv RT X400/35 RMv RT X500/35 RMv RT X630/35 RMv RT X800/35 RMv RT

42 POWER POWER / MEDIUM VOLTAGE NA2XSY 6/10 kv ELECTRONIC LAN COAXIAL Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo VDE /IEC C 70 C C 15 x DA 6000 V Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE cables must be protected from sunlight. Al. weight X50/16 RMv RT X70/16 RMv RT X70/25 RMv RT X95/16 RMv RT X120/16 RMv RT X120/50 RMv RT X150/16 RMv RT X150/25 RMv RT X185/16 RMv RT X185/25 RMv RT X240/16 RMv RT X240/25 RMv RT X300/25 RMv RT X400/35 RMv RT X500/35 RMv RT X630/35 RMv RT X800/35 RMv RT

43 NA2XSY 12/20 kv MEDIUM VOLTAGE / POWER POWER COAXIAL Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo VDE /IEC ELECTRONIC LAN 90 C 70 C C 15 x DA V Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE cables must be protected from sunlight. Al. weight X50/16 RMv RT X70/16 RMv RT X95/16 RMv RT X120/16 RMv RT X150/16 RMv RT X150/25 RMv RT X185/16 RMv RT X185/25 RMv RT X240/16 RMv RT X240/25 RMv RT X300/25 RMv RT X400/35 RMv RT X500/35 RMv RT X630/35 RMv RT X800/35 RMv RT

44 POWER POWER / MEDIUM VOLTAGE NA2XSY 18/30 kv ELECTRONIC LAN COAXIAL Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo VDE /IEC C 70 C C 15 x DA V Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE cables must be protected from sunlight. Al. weight X50/16 RMv RT X70/16 RMv RT X70/25 RMv RT X95/16 RMv RT X120/16 RMv RT X150/16 RMv RT X150/25 RMv RT X185/16 RMv RT X185/25 RMv RT X240/16 RMv RT X240/25 RMv RT X300/25 RMv RT X400/35 RMv RT X500/35 RMv RT X630/35 RMv RT X1000/35 RMv RT

45 N2XS2Y 6/10 kv MEDIUM VOLTAGE / POWER POWER COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Colour outer sheath black no ELECTRONIC LAN Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo 90 C 70 C C 15 x DA 6000 V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation X35/16 RM SW X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/16 RMv SW X150/25 RMv SW X185/16 RMv SW X185/25 RMv SW X240/16 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW

46 POWER POWER / MEDIUM VOLTAGE N2XS2Y 12/20 kv ELECTRONIC LAN COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Colour outer sheath black no Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo 90 C 70 C C 15 x DA V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation X35/16 RM SW X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/16 RMv SW X150/25 RMv SW X185/16 RMv SW X185/25 RMv SW X240/16 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW

47 N2XS2Y 18/30 kv MEDIUM VOLTAGE / POWER POWER COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Colour outer sheath black no ELECTRONIC LAN Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo 90 C 70 C C 15 x DA V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X240/70 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW

48 POWER POWER / MEDIUM VOLTAGE NA2XS2Y 6/10 kv COAXIAL ELECTRONIC LAN Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Colour outer sheath black no Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo 90 C 70 C C 15 x DA 6000 V Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. Al. weight X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW

49 NA2XS2Y 12/20 kv MEDIUM VOLTAGE / POWER POWER COAXIAL Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Colour outer sheath black no Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo ELECTRONIC LAN 90 C 70 C C 15 x DA V Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. Al. weight X35/16 RM SW X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW

50 POWER POWER / MEDIUM VOLTAGE NA2XS2Y 18/30 kv ELECTRONIC LAN COAXIAL Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Colour outer sheath black no Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo 90 C 70 C C 15 x DA V Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. Al. weight X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW

51 N2XS(F)2Y 6/10 kv MEDIUM VOLTAGE / POWER POWER ELECTRONIC LAN COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature temperature, in motion/ during installation 90 C 70 C C For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage X35/16 RM SW X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW

52 POWER POWER / MEDIUM VOLTAGE N2XS(F)2Y 12/20 kv ELECTRONIC COAXIAL LAN Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature temperature, in motion/ during installation 90 C 70 C C For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage X35/16 RM SW X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW X1000/35 RMv SW

53 N2XS(F)2Y 18/30 kv MEDIUM VOLTAGE / POWER POWER ELECTRONIC LAN COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature temperature, in motion/ during installation 90 C 70 C C For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zerohalogen, yet not flame-retardant as defined under DIN VDE This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW X1000/35 RMv SW

54 POWER POWER / MEDIUM VOLTAGE NA2XS(F)2Y 6/10 kv ELECTRONIC COAXIAL LAN Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature temperature, in motion/ during installation 90 C 70 C C Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage. Al. weight X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW X1000/35 RMv SW

55 NA2XS(F)2Y 12/20 kv MEDIUM VOLTAGE / POWER POWER COAXIAL ELECTRONIC LAN Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature temperature, in motion/ during installation 90 C 70 C C Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage. Al. weight X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW X1000/35 RMv SW

56 POWER POWER / MEDIUM VOLTAGE NA2XS(F)2Y 18/30 kv ELECTRONIC COAXIAL LAN Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature temperature, in motion/ during installation 90 C 70 C C Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage. Al. weight X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW X1000/35 RMv SW

57 N2XS(FL)2Y 6/10 kv MEDIUM VOLTAGE / POWER POWER Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black UV-resistant yes Maximum permitted conductor temperature 90 C 70 C For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration both crosswise and lengthwise following mechanical damage X35/16 RM SW X50/16 RMv SW X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW ELECTRONIC N2XS(FL)2Y 12/20 kv LAN Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 polyethylene DMP2 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black UV-resistant yes Maximum permitted conductor temperature 90 C 70 C For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration both crosswise and lengthwise following mechanical damage X35/16 RM SW X50/16 RMv SW X70/16 RMv SW COAXIAL

58 POWER POWER / MEDIUM VOLTAGE N2XS(FL)2Y 12/20 kv X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW NA2XS(FL)2Y 6/10 kv ELECTRONIC LAN COAXIAL Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature 90 C Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration both crosswise and lengthwise following mechanical damage. Al. weight X120/16 RMv SW X150/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/50 RMv SW X800/35 RMv SW

59 NA2XS(FL)2Y 12/20 kv MEDIUM VOLTAGE / POWER POWER Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature 90 C Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration both crosswise and lengthwise following mechanical damage. Al. weight X70/16 RMv SW X120/16 RMv SW X150/25 RMv SW X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW X630/35 RMv SW X800/35 RMv SW NA2XS(FL)2Y 18/30 kv ELECTRONIC LAN Standard VDE Application: aluminium class 2 = stranded XLPE DIX8 polyethylene DMP2 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black no UV-resistant yes Maximum permitted conductor temperature 90 C Item number Item name Colour Cop. weight For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration both crosswise and lengthwise following mechanical damage. Al. weight X70/16 RMv SW X95/16 RMv SW X120/16 RMv SW X150/25 RMv SW COAXIAL 59

60 POWER POWER / MEDIUM VOLTAGE NA2XS(FL)2Y 18/30 kv Item number Item name Colour Cop. weight Al. weight X185/25 RMv SW X240/25 RMv SW X300/25 RMv SW X400/35 RMv SW X500/35 RMv SW N2XSEY 6/10 kv ELECTRONIC LAN COAXIAL Standard VDE Application: bare copper class 2 = stranded XLPE DIX8 PVC DMV6 Colour outer sheath red Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo VDE /IEC C 70 C C 15 x DA 6000 V For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable allow an easy installation, even on difficult routes. According to VDE cables must be protected from sunlight X35/16 RM RT X50/16 RM RT X70/16 RM RT X95/16 RM RT X120/16 RM RT X150/25 RM RT X185/25 RM RT X240/25 RM RT X300/25 RM RT

61 NFA2X OVERHEAD LINES / POWER POWER Standard VDE 0274 (Z) Application: aluminium For aboveground distribution grids, primarily for public distribution grids class 2 = stranded with a highest mains voltage not XLPE above 1,2 kv. UV-resistant yes C Nominal voltage Uo 600 V Nominal voltage U 1000 V Item number Item name Colour Al. weight ELECTRONIC COAXIAL LAN X25 RM SW X16 RM SW X25 RM SW X35 RM SW X50 RM SW X70 RM SW X16 RM SW X35 RM SW X50 RM SW X70 RM SW X70 + 1X25 RM SW X70 + 1X35 RM SW X70 + 2X25 RM SW X70 + 2X35 RM SW X95 RM SW X95 + 1X35 RM SW

62 NOTES COAXIAL LAN ELECTRONIC POWER 62

63 POWER ELECTRONIC COAXIAL LAN SHEATHED 64 NYM-J 64 NYM-O 65 (N)YM(St)-J 66 NYIF-J 67 NHXMH-J 67 (N)HXMH(St)-J 68

64 POWER / SHEATHED NYM-J ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca Standard VDE bare copper class 1, up from 16 sq class 2 PVC TI1 PVC TM1 Colour outer sheath grey RAL 7035 VDE /IEC C temperature, in motion/ 5-70 C during installation Nominal voltage Uo 300 V Nominal voltage U 500 V Application: For installation in, on or under plaster, in dry, damp or wet rooms as well as in walls and concrete (except for shaken, jolted, tamped concrete). Also suitable for installation outdoors if protected from sunlight X2.5 RE GR X4 RE GR X6 RE GR X10 RE GR X16 RM GR X25 RM GR X1.5 RE GR X1.5/TR RE GR X1.5/KTR RE GR X2.5 RE GR X2.5/TR RE GR X2.5/KTR RE GR X4 RE GR X6 RE GR X10 RE GR X1.5 RE GR X1.5/TR RE GR X1.5/KTR RE GR X2.5 RE GR X2.5/TR RE GR X4 RE GR X6 RE GR X10 RE GR X16 RM GR X25 RM GR X35 RM GR X1.5 RE GR X1.5/TR RE GR X1.5/KTR RE GR X2.5 RE GR X2.5/TR RE GR X4 RE GR X6 RE GR X10 RE GR X16 RM GR X25 RM GR X35 RM GR X1.5 RE GR

65 NYM-J SHEATHED / POWER X2.5 RE GR X1.5 RE GR X1.5 RE GR X1.5 RE GR X2.5 RE GR NYM-O CPR-performance acc. to EN Eca Standard VDE bare copper class 1, up from 16 sq class 2 PVC TI1 PVC TM1 Colour outer sheath grey RAL 7035 VDE /IEC C temperature, in motion/ 5-70 C during installation Nominal voltage Uo 300 V Nominal voltage U 500 V ELECTRONIC LAN COAXIAL Application: For installation in, on or under plaster, in dry, damp or wet rooms as well as in walls and concrete (except for shaken, jolted, tamped concrete). Also suitable for installation outdoors if protected from sunlight X1.5 RE GR X2.5 RE GR X4 RE GR X6 RE GR X10 RE GR X16 RM GR X1.5 RE GR X1.5/TR RE GR X2.5 RE GR X2.5/TR RE GR X1.5 RE GR X1.5/TR RE GR X1.5 RE GR X1.5/TR RE GR X6 RE GR X10 RE GR X16 RM GR X25 RM GR X35 RM GR X1.5 RE GR X1.5 RE GR

66 POWER / SHEATHED (N)YM(St)-J CPR-performance acc. to EN Eca bare copper PVC TI1 Screen foil Drain wire yes PVC TM1 Colour outer sheath grey RAL 7035 VDE /IEC C temperature, in motion/ 5-70 C during installation Nominal voltage Uo 300 V Nominal voltage U 500 V Application: This installation cable is statically shielded for limiting the electromagnetic fields of currentcarrying conductors in sensitive environments such as IT, hospitals, but also for installation in homes where a particular sensitivity to electromagnetic fields is provided. For installation on, over, in and under plaster in dry, humid and wet rooms as well as in masonry and concrete (except for shaken, jolted, tamped concrete). Also for use outdoors if protected from direct sunlight. ELECTRONIC LAN COAXIAL X1.5 RE GR X1.5 RE GR X1.5 RE GR X1.5 RE GR X2.5 RE GR X2.5 RE GR X2.5 RE GR X4 RE GR X4 RE GR X6 RE GR X6 RE GR X10 RE GR X16 RM GR

67 NYIF-J SHEATHED / LAN POWER NHXMH-J CPR-performance acc. to EN Fca Standard VDE bare copper PVC TI1 cross-linked rubber blend VDE /IEC C temperature, in motion/ 5-60 C during installation Nominal voltage Uo 230 V Nominal voltage U 400 V Core identification colours acc. to VDE 0293 (HD308) VDE yes ELECTRONIC Application: For fixed installation in dry rooms, on and under plaster. Without plaster sheet in cavities of ceilings and walls of not combustible building materials. W x H X1.5 RE NT x X1.5 RE NT x X1.5 RE NT x X2.5 RE NT x X2.5 RE NT x CPR-performance acc. to EN on request Standard VDE 0250 T. 214 bare copper XLPE 2XI1 FRNC-compound HM2 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C temperature, in motion/ 5-70 C during installation Nominal voltage Uo 300 V Nominal voltage U 500 V Application: Low-smoke, zero-halogen, flameretardant building wire, for installation on and under plaster in dry and wet rooms, as well as in concrete (except for shaken, jolted, tamped concrete). For indoor use only, primarily in buildings with a high concentration of people and material assets X1.5 RE GR X2.5 RE GR X4 RE GR X6 RE GR COAXIAL

68 POWER / SHEATHED NHXMH-J ELECTRONIC X10 RE GR X16 RM GR X25 RM GR X1.5 RE GR X2.5 RE GR X4 RE GR X6 RE GR X10 RE GR X1.5 RE GR X2.5 RE GR X4 RE GR X6 RE GR X10 RE GR X16 RM GR X25 RM GR X35 RM GR X1.5 RE GR X2.5 RE GR X4 RE GR X6 RE GR X10 RE GR X16 RM GR X25 RM GR X1.5 RE GR X2.5 RE GR X1.5 RE GR X1.5 RE GR X1.5 RE GR X2.5 RE GR LAN (N)HXMH(St)-J COAXIAL CPR-performance acc. to EN on request bare copper XLPE 2XI1 Screen foil Drain wire yes FRNC-compound HM2 Colour outer sheath grey RAL 7035 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Nominal voltage Uo 300 V Nominal voltage U 500 V Application: Low-smoke, zero-halogen, flameretardant building wire, for installation on and under plaster in dry and wet rooms, as well as in concrete (except for shaken, jolted, tamped concrete). For indoor use only, primarily in buildings with a high concentration of people and material assets. The cable is screened to limit propagation of electromagnetic field of the conductors. It is designed for application in EMC-sensitive environments as hospitals, data processing facilities, laboratories but also in living rooms X1.5/1.5 RE GR X2.5/1.5 RE GR X1.5/1.5 RE GR X1.5/1.5 RE GR X2.5/1.5 RE GR X1.5/1.5 RE GR

69 POWER ELECTRONIC LAN COAXIAL SINGLE CORES 70 H05V-U 70 H05V-K 71 H07V-U 72 H07V-R 73 H07V-K 74 H05Z-K 76 H07Z-K 77 NSHXAFOE 1.8/3 kv 78 INSULATED CORDS 79 H03VV-F 79 H05VV-F 79 H05Z1Z1-F 80 SPEAKER 82 YFAZ 82 RUBBER INSULATED 83 H05RN-F 83 H05RR-F 83 H07RN-F 84 H07ZZ-F 86 H01N2-D - Cable with normal flexibility 87 H1Z2Z2-K 87 NSSHOEU-J 88 NSSHOEU-O 89 NSSHOEU /3E 90 NSHTOEU 91 Submersible pump cable (-J) 92 H05RNH2-F 93 GGSG 93 NGFLGOEU 94 NGFLCGOEU 95 A05RN-F 95 FABER Jalousie FRNC 96 NSGAFOEU 1.8/3 kv 96 PUR-INSULATED 98 H05BQ-F 98 H07BQ-F (without filler) 98 X07BQ-F (without filler) 99 X07BQ-F (with filler) 100 SILICONE INSULATED 101 SiD 101 SiF 102 H05SJ-K 103 SiF/GL 104 FZLSi 105 2GTL 13.8/15 kv 105 SiHF-J 106 SiHF-O 107 SiHFC-Si-J/-O 108 SiHF/GLS-P 109 H05SS-F 110 H05SS-F (UL) 111 SPECIAL 112 Livz6YYw 112 Li2GYw (SiHYw PV/P) 112 NYL 113 FABER THERM 145 (Single core) 113 FABER THERM TRAILING 115 (N)TMCGCWOEU 12/20 kv 115 (N)TSCGEWOEU MT PLUS 12/20 kv 115

70 POWER / SINGLE CORES H05V-U CPR-performance acc. to EN on request Standard EN bare copper class 1 = solid PVC TI1 VDE /IEC Maximum permitted conductor temperature 70 C 70 C Bending radius, fixed installation 4 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V HAR yes Application: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster. ELECTRONIC LAN COAXIAL X0.75 SW X0.75 HB X0.75 WS X0.75 GG X0.75 BR X0.75 GR X0.75 RT X1 SW X1 GG X1 BL X1 HB X1 GR X1 RT X1 WS X1 BR X1 VL

71 H05V-K SINGLE CORES / POWER CPR-performance acc. to EN on request Standard EN bare copper class 5 = fine stranded PVC TI1 VDE /IEC Maximum permitted conductor temperature 70 C 70 C Bending radius, fixed installation 4 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V HAR yes Application: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster X0.5 SW X0.5 (barrel pack) SW X0.5 WS X0.5 VL X0.5 GG X0.5 RT X0.5 (barrel pack) RT X0.5 BR X0.5 (barrel pack) BR X0.5 HB X0.5 GR X0.5 DB X0.5 (barrel pack) DB X0.5 OR X0.75 SW X0.75 (barrel pack) SW X0.75 HB X0.75 (barrel pack) HB X0.75 GG X0.75 (barrel pack) GG X0.75 (barrel pack) WS X0.75 GR X0.75 RT X0.75 (barrel pack) RT X0.75 BR X0.75 (barrel pack) BR X0.75 VL X0.75 (barrel pack) VL X0.75 (barrel pack) OR X0.75 DB X0.75 (barrel pack) DB X1 SW X1 (barrel pack) SW X1 GG X1 (barrel pack) GG X1 WS X1 (barrel pack) WS X1 GR X1 (barrel pack) GR X1 RT X1 (barrel pack) RT X1 HB ELECTRONIC LAN COAXIAL

72 POWER / SINGLE CORES H05V-K X1 (barrel pack) HB X1 BR X1 (barrel pack) BR X1 VL X1 (barrel pack) VL X1 OR X1 (barrel pack) OR X1 DB X1 (barrel pack) DB H07V-U ELECTRONIC CPR-performance acc. to EN Eca Standard EN bare copper class 1 = solid PVC TI1 VDE /IEC Maximum permitted conductor temperature 70 C temperature, in motion/ 5-70 C during installation Bending radius, fixed installation 4 x DA Nominal voltage Uo 450 V Nominal voltage U 750 V HAR yes Application: For laying in pipes on top of or under plaster and in closed installation ducts and for internal wiring of machinery, switchgear and distributor systems. The cable is not suitable for direct laying under plaster. LAN COAXIAL X1.5 SW X1.5 GG X1.5 HB X1.5 BR X1.5 GR X1.5 VL X1.5 RT X1.5 WS X1.5 DB X2.5 SW X2.5 GG X2.5 HB X2.5 BR X2.5 GR X2.5 VL X2.5 RT X2.5 DB X4 SW X4 GG X4 HB X4 BR X4 GR X6 SW X6 GG

73 H07V-U SINGLE CORES / POWER X6 HB X6 BR X10 SW X10 GG X10 HB H07V-R CPR-performance acc. to EN Eca Standard EN bare copper class 2 = stranded PVC TI1 VDE /IEC Maximum permitted conductor temperature 70 C temperature, in motion/ 5-70 C during installation Bending radius, fixed installation 6 x DA Nominal voltage Uo 450 V Nominal voltage U 750 V HAR yes ELECTRONIC LAN COAXIAL Application: For laying in pipes on top of or under plaster and in closed installation ducts and for internal wiring of machinery, switchgear and distributor systems. The cable is not suitable for direct laying under plaster X16 SW X16 GG X25 SW X25 GG X35 SW X35 GG X50 SW X50 GG X70 SW X70 GG X95 SW X95 GG X120 SW X120 GG X150 GG X185 SW

74 POWER / SINGLE CORES H07V-K ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca Standard EN bare copper class 5 = fine stranded PVC TI1 VDE /IEC Maximum permitted conductor temperature 70 C temperature, in motion/ 5-70 C during installation Bending radius, fixed installation 4 x DA Nominal voltage Uo 450 V Nominal voltage U 750 V HAR yes Application: For laying in pipes on top of or under plaster and in closed installation ducts and for internal wiring of machinery, switchgear and distributor systems. The cable is not suitable for direct laying under plaster X1.5 SW X1.5 (barrel pack) SW X1.5 GG X1.5 (barrel pack) GG X1.5 HB X1.5 (barrel pack) HB X1.5 BR X1.5 (barrel pack) BR X1.5 GR X1.5 (barrel pack) GR X1.5 VL X1.5 RT X1.5 (barrel pack) RT X1.5 WS X1.5 (barrel pack) WS X1.5 OR X1.5 (barrel pack) OR X1.5 DB X1.5 (barrel pack) DB X2.5 SW X2.5 (barrel pack) SW X2.5 GG X2.5 (barrel pack) GG X2.5 HB X2.5 (barrel pack) HB X2.5 BR X2.5 (barrel pack) BR X2.5 GR X2.5 VL X2.5 RT X2.5 (barrel pack) RT X2.5 WS X2.5 DB X4 SW X4 (barrel pack) SW X4 GG X4 (barrel pack) GG X4 HB X4 (barrel pack) HB X4 BR X4 (barrel pack) BR

75 H07V-K SINGLE CORES / X4 RT X4 GR X4 DB X6 SW X6 (barrel pack) SW X6 GG X6 (barrel pack) GG X6 HB X6 (barrel pack) HB X6 BR X6 (barrel pack) BR X6 RT X6 GR X6 DB X10 SW X10 GG X10 HB X10 BR X10 RT X10 DB X16 SW X16 GG X16 HB X16 DB X16 BR X16 RT X16 GR X25 SW X25 GG X25 HB X25 BR X35 SW X35 GG X35 HB X35 WS X50 SW X50 GG X70 SW X70 GG X95 SW X95 GG X120 SW X120 GG X150 SW X150 GG X185 SW X185 GG X240 SW X240 GG POWER ELECTRONIC LAN COAXIAL 75

76 POWER / SINGLE CORES H05Z-K CPR-performance acc. to EN Eca Standard EN bare copper class 5 = fine stranded polyolefin EI5, halogen-free, cross-linked VDE /IEC Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C 70 C Nominal voltage Uo 300 V Nominal voltage U 500 V Application: For installation in pipes and ducts on and under plaster, in closed installation ducts and for the internal wiring of electrical appliances, switching and distribution tools. Primarily in buildings with a high concentration of people and material assets as well as in buses and railborne vehicles. ELECTRONIC LAN COAXIAL X0.5 SW X0.5 GG X0.5 GR X0.5 HB X0.5 BR X0.5 DB X0.5 RT X0.75 SW X0.75 GG X0.75 HB X0.75 BR X0.75 DB X0.75 RT X1 SW X1 GG X1 GR X1 HB X1 BR X1 DB X1 RT

77 H07Z-K SINGLE CORES / POWER CPR-performance acc. to EN Eca Standard EN bare copper class 5 = fine stranded polyolefin EI5, halogen-free, cross-linked VDE /IEC Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C 70 C Nominal voltage Uo 450 V Nominal voltage U 750 V Application: For installation in pipes and ducts on and under plaster, in closed installation ducts and for the internal wiring of electrical appliances, switching and distribution tools. Primarily in buildings with a high concentration of people and material assets as well as in buses and railborne vehicles X1.5 SW X1.5 GG X1.5 HB X1.5 BR X1.5 DB X1.5 RT X2.5 SW X2.5 GG X2.5 HB X2.5 BR X2.5 RT X4 SW X4 GG X4 HB X4 BR X4 DB X4 RT X6 SW X6 GG X6 HB X6 BR X6 DB X6 RT X10 SW X10 GG X10 DB X16 SW X16 GG X16 DB X16 RT X25 SW X25 GG X25 RT X35 SW X35 GG X50 SW X50 GG X70 SW X70 GG X95 SW X95 GG ELECTRONIC LAN COAXIAL 77

78 POWER / SINGLE CORES H07Z-K X120 SW X120 GG X150 SW X150 GG X185 SW NSHXAFOE 1.8/3 kv ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca Standard VDE 0250 T. 606 tinned copper class 5 = fine stranded rubber (EPR) 3GI3, halogenfree FRNC compound HM3 VDE /IEC Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN Maximum permitted conductor temperature 90 C C Application: This insulated wire is designed for application in buses and rail-borne vehicles. If used in distribution or switching appliances up to 1000 V, it is considered to be short circuit-proof and earth leakage-proof. The cable is halogen-free, flame-retardant and resistant to most oils and grease X1.5 SW X2.5 SW X4 SW X6 SW X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW X120 SW X150 SW X185 SW X240 SW X300 SW X500 SW

79 H03VV-F INSULATED CORDS / POWER H05VV-F Standard EN Application: bare copper class 5 = fine stranded PVC YI2 PVC TM2 Maximum permitted conductor temperature Bending radius, fixed installation Bending radius, moving application Nominal voltage Uo Nominal voltage U VDE /IEC C 50 C 3 x DA 5 x DA 300 V 300 V For the connection of small electrical appliances (table and standard lamps, kitchen appliances, domestic vacuum cleaners, office appliances, radios etc.) at low mechanical stress in household, kitchen and office. Not for the connection of cooking and heating appliances or coercial electric tools. Not for outdoor use, in agricultural or coercial businesses X0.75 SW X0.75 WS G0.75 WS G0.75 SW G0.75 SW G0.75 WS LAN ELECTRONIC Standard EN Application: bare copper class 5 = fine stranded PVC YI2 PVC TM2 Maximum permitted conductor temperature Bending radius, fixed installation Bending radius, moving application Nominal voltage Uo Nominal voltage U VDE /IEC C 50 C 3 x DA 5 x DA 300 V 500 V Suitable for medium mechanical stress in household, kitchen and office rooms. For household appliances even in damp rooms. Suitable for cooking and heating devices if provided that the cable is not in contact with hot parts or is exposed to heat radiation. Not for permanent outdoor use X0.75 WS X1 SW X1 WS X1.5 SW COAXIAL

80 POWER ELECTRONIC / INSULATED CORDS H05VV-F X1.5 WS X2.5 SW X2.5 WS G0.75 SW G0.75 WS G1 WS G1 SW G1.5 WS G1.5 SW G1.5 GR G2.5 WS G2.5 SW G0.75 SW G0.75 WS G1 SW G1 WS G1.5 SW G1.5 WS G2.5 WS G2.5 SW G0.75 SW G0.75 WS G1 SW G1 WS G1.5 WS G1.5 SW G2.5 SW H05Z1Z1-F LAN COAXIAL Standard EN Application: bare copper For connecting of electrical appliances under low mechanical class 5 = fine stranded stress in household, kitchen and FRNC compound TI6 office. FRNC compound TM7 VDE /IEC (Kat. C) Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 3 x DA Bending radius, moving application 5 x DA X0.75 WS G0.75 WS G0.75 SW G0.75 WS G1 WS G1 WS

81 H05Z1Z1-F INSULATED CORDS / X1.5 WS G1.5 WS G1.5 SW G1.5 WS G2.5 WS POWER COAXIAL LAN ELECTRONIC 81

82 POWER / SPEAKER YFAZ ELECTRONIC oxygen-free copper (OFC) Application: class 6 = extra finely stranded PVC temperature, in motion/ during installation resistance Nominal voltage Uo Nominal voltage U VDE /IEC C C COAXIAL LAN 20 MOhmxkm 50 V 75 V Universally applicable: High-quality speaker cable for home application as well as for use in cinemas, theatres and other public buildings. The special construction of copper conductor ensures a long-life flexibility of the cable. W x H X0.75/0.2 SW x X0.75/0.2 TR x X1.5/0.15 TR x X2.5/0.15 TR x X4/0.15 TR x X6/0.15 TR x X10/0.15 TR x

83 H05RN-F RUBBER INSULATED / POWER H05RR-F Standard EN Application: bare copper class 5 = fine stranded rubber (EPR) EI4 rubber (CR) EM2 Maximum permitted conductor temperature Nominal voltage Uo Nominal voltage U Core identification HAR VDE /IEC C C 300 V 500 V colours acc. to VDE 0293 (HD308) yes For the connection of electrical appliances (vacuum cleaners, kitchen appliances, soldering iron etc.) with low mechanical stress in household, kitchen, office. Not for permanent outdoor use X0.75 SW X1 SW G0.75 SW G1 SW X0.75 SW G0.75 SW LAN ELECTRONIC Standard EN Application: bare copper class 5 = fine stranded rubber (EPR) EI4 rubber EM3 Maximum permitted conductor temperature Nominal voltage Uo Nominal voltage U Core identification HAR 60 C C 300 V 500 V colours acc. to VDE 0293 (HD308) yes For the connection of electrical appliances (vacuum cleaners, kitchen appliances, soldering iron etc.) with low mechanical stress in household, kitchen, office. Not for permanent outdoor use. COAXIAL X0.75 SW X1 SW X1.5 SW X2.5 SW G1 SW G1.5 SW G2.5 SW

84 POWER / RUBBER INSULATED H05RR-F G0.75 SW G1 SW G1.5 SW G2.5 SW G0.75 SW G1.5 SW G2.5 SW H07RN-F ELECTRONIC CPR-performance acc. to EN Eca Standard EN bare copper class 5 = fine stranded rubber (EPR) EI4 rubber (CR) EM2 VDE /IEC Oil-resistant EN Ozone-resistant yes Maximum permitted conductor temperature 80 C C temperature, in motion/ C during installation Application: For use at medium mechanical stress in dry, wet and damp locations, as well as outdoors. Also for fixed installation on plaster or machines. The cable is oil-, UV- and ozoneresistant. LAN COAXIAL X1.5 SW X2.5 SW X4 SW X6 SW X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW X120 SW X150 SW X185 SW X240 SW X300 SW X400 SW X1 SW X1.5 SW X2.5 SW X4 SW X6 SW X1 SW G1 SW X1.5 SW G1.5 SW G2.5 SW G4 SW G6 SW

85 H07RN-F RUBBER INSULATED / G10 SW G16 SW G25 SW G35 SW G50 SW G1 SW G1.5 SW G2.5 SW G4 SW G6 SW G10 SW G16 SW G25 SW G35 SW G50 SW G70 SW G95 SW G120 SW G150 SW G185 SW G240 SW G1.5 SW G2.5 SW G4 SW G6 SW G10 SW G16 SW G25 SW G35 SW G50 SW G70 SW G95 SW G120 SW G150 SW G1.5 SW G2.5 SW G1.5 SW G2.5 SW G1.5 SW G2.5 SW G1.5 SW G2.5 SW G1.5 SW POWER ELECTRONIC LAN COAXIAL 85

86 POWER / RUBBER INSULATED H07ZZ-F Standard EN Application: bare copper class 5 = fine stranded rubber EI8 rubber (EPR) EM8 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Nominal voltage Uo 450 V These cables are designed for indoor and outdoor installation, particularly for applications where only small quantities of smoke and corrosive gases may be emitted in the event of a fire. ELECTRONIC LAN COAXIAL X1 SW X1.5 SW X2.5 SW G1 SW G1.5 SW G2.5 SW G4 SW G1 SW G1.5 SW G2.5 SW G4 SW G6 SW G10 SW G16 SW G25 SW G35 SW G50 SW G70 SW G95 SW G120 SW G150 SW G1 SW G1.5 SW G2.5 SW G4 SW G6 SW G10 SW G16 SW G25 SW G35 SW G1.5 SW G2.5 SW G1.5 SW G2.5 SW G2.5 SW G1.5 SW G2.5 SW G1.5 SW G2.5 SW G1.5 SW G1.5 SW

87 H01N2-D - Cable with normal flexibility RUBBER INSULATED / POWER H1Z2Z2-K Standard EN Application: copper, bare or tinned In dry, damp and wet rooms as welding cable for machine or hand class 6 = extra finely stranded operation. rubber (CR) EM5 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 85 C C Nominal voltage Uo 100 V Nominal voltage U 100 V HAR yes X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW X120 SW X150 SW ELECTRONIC LAN CPR-performance acc. to EN Eca Standard VDE tinned copper class 5 = fine stranded cross-linked polyolefincopolymer cross-linked polyolefincopolymer VDE /IEC Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN Ozone-resistant yes Maximum permitted conductor temperature 120 C Application: Solar line for freely movable use or fixed installation in photovoltaic systems as per EN The cable may be used indoors, outdoors, in explosive areas, in industrial or agricultural operations and is approved for direct laying in the ground. The cable is regarded as short-circuit-proof and earth leakageproof. It meets the VDE application regulation VDE-AR-E The cable has been subjected to the following additional tests: - abrasion as per EN water AD 7 as per HD oil-resistance as per NEK 606/ EN Please note the applicable installation instructions on our website X4 SW X4 BL X4 RT X6 SW COAXIAL

88 POWER / RUBBER INSULATED H1Z2Z2-K X6 BL X6 RT X10 SW X10 BL X10 RT X16 SW X16 BL X16 RT X25 SW X25 BL X25 RT X35 SW X35 BL X35 RT NSSHOEU-J ELECTRONIC LAN Standard VDE 0250 T. 812 Application: tinned copper class 5 = fine stranded rubber (EPR) 3GI3, halogenfree rubber (CR) 5GM5 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Nominal voltage Uo 600 V Nominal voltage U 1000 V Designed to withstand high mechanical stress. For the connection of heavy duty underground mining, industrial and construction equipment, in dry and damp areas and outdoors. The cable is largely flameand oil-resistant. COAXIAL X1.5 GE X2.5 GE X70/35 GE X95/50 GE X120/70 GE X150/70 GE X1.5 GE X2.5 GE X4 GE X6 GE X10 GE X16 GE X25 GE X35 GE X50 GE X70 GE X95 GE X120 GE X150 GE X1.5 GE X2.5 GE X4 GE

89 NSSHOEU-J RUBBER INSULATED / X6 GE X10 GE X16 GE X25 GE X35 GE X1.5 GE X2.5 GE X1.5 GE X1.5 GE X2.5 GE X2.5 GE X1.5 GE POWER NSSHOEU-O Standard VDE 0250 T. 812 Application: tinned copper class 5 = fine stranded rubber (EPR) 3GI3, halogenfree rubber (CR) 5GM5 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Nominal voltage Uo 600 V Nominal voltage U 1000 V ELECTRONIC LAN COAXIAL Designed to withstand high mechanical stress. For the connection of heavy duty underground mining, industrial and construction equipment, in dry and damp areas and outdoors. The cable is largely flameand oil-resistant X16 GE X25 GE X35 GE X50 GE X70 GE X95 GE X120 GE X150 GE X185 GE X240 GE X300 GE X1.5 GE /en/ 89

90 POWER / RUBBER INSULATED NSSHOEU /3E ELECTRONIC LAN Standard VDE 0250 T. 812 Application: tinned copper class 5 = fine stranded rubber (EPR) 3GI3, halogenfree rubber (CR) 5GM5 VDE /IEC Oil-resistant EN Ozone-resistant yes Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Nominal voltage Uo 600 V COAXIAL Designed to withstand high mechanical stress. For the connection of heavy duty underground mining, industrial and construction equipment, in dry and damp areas and outdoors. The cable is largely flameand oil-resistant. For applications with specific requirements to EMC X X2.5/3E + 3X1.5 St GE X6 + 3X6/3E + 3X1.5 St GE X10 + 3X10/3E + 3X2.5 St GE X16 + 3X16/3E + 3X2.5 St GE X25 + 3X16/3E + 3X2.5 St GE X35 + 3X16/3E + 3X2.5 St GE X50 + 3X25/3E + 3X2.5 St GE X70 + 3X35/3E + 3X2.5 St GE X95 + 3X50/3E + 3X2.5 St GE X X70/3E + 3X2.5 St GE X X95/3E + 3X2.5 St GE

91 NSHTOEU RUBBER INSULATED / POWER Standard VDE 0250 T. 814 Application: tinned copper class 5 = fine stranded Material inner sheath Torsion protection Torsion Colour outer sheath Oil-resistant Maximum permitted conductor temperature rubber (EPR) 3GI3, halogenfree rubber GM1b polyester braid +/- 25 /m rubber (CR) 5GM3 black VDE /IEC yes 90 C As connection and reelable control cable in lifting devices, hoisting plants and transporting machines for heavy mechanical load, and as drum and drag cable or hawser in dry, damp or wet rooms and in wet industrial conditions. The cable is resistant to acids, lyes, and oils. Please refer to the relevant installation guidelines on our website X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X4 SW X6 SW X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW X120 SW X150 SW X185 SW X4 SW X6 SW X10 SW X16 SW ELECTRONIC LAN COAXIAL 91

92 POWER / RUBBER INSULATED Submersible pump cable (-J) ELECTRONIC LAN COAXIAL tinned copper Application: class 5 = fine stranded rubber EI7 rubber (CR) 5GM3 Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Bending radius, moving application Nominal voltage Uo Nominal voltage U Core identification 90 C C C 3 x DA 5 x DA 450 V 750 V colours acc. to VDE 0293 (HD 308); more than 5 cores: gn-ye + numbers As connection cable for submersible electric motors (pumps) for the permanent use in potable water up to temperature of 70 C and to a depth of 600 m. The cable is resistant to chlorine, sea water and liquid manure. It is suitable for use in dry, damp and wet rooms with medium mechanical stress. Test certificates of different national and international institutes are available on request X1.5 BL X2.5 BL X1.5 BL X2.5 BL X4 BL X6 BL X10 BL X16 BL X25 BL X35 BL X50 BL X70 BL X95 BL X1.5 BL X1.5 BL X2.5 BL X2.5 BL

93 H05RNH2-F RUBBER INSULATED / POWER Standard EN Application: bare copper The cable is suitable for dry and wet rooms as well as outdoors for class 5 = fine stranded temporary installation of fairy lights. rubber (EPR) EI4 rubber (CR) EM2 VDE /IEC Maximum permitted conductor temperature 60 C C Nominal voltage Uo 300 V Nominal voltage U 500 V Core identification colours acc. to VDE 0293 (HD308) HAR yes W x H X1.5 GN x X2.5 SW x ELECTRONIC GGSG bare copper Application: class 5 = fine stranded The cable is designed for use in the rail sector, where narrow bending rubber EI7 radii and vibrations may occur. The Material inner sheath rubber EM7 product approval of Deutsche Bahn Screen copper wires AG can be provided on request. rubber EM7 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Bending radius, fixed installation 6 x DA LAN COAXIAL X300/95 RT

94 POWER / RUBBER INSULATED NGFLGOEU ELECTRONIC LAN COAXIAL Standard VDE 0250 T. 809 Application: bare copper class 6 = extra finely stranded, up from 35 sq class 5 rubber (EPR) 3GI3, halogenfree rubber (CR) 5GM3 VDE /IEC Oil-resistant EN Ozone-resistant yes Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Bending radius, fixed installation 5 x DA For the connection of mobile parts of machine tools, conveyor plants and large-scale equipment, if the cable is exposed to bends in only one level (cable trolley). In dry, damp and wet rooms as well as outdoors. W x H X1.5 SW x X1.5 SW x X1.5 SW x X1.5 SW x X1.5 SW x X1.5 SW x X1.5 SW x X2.5 SW x X2.5 SW x X2.5 SW x X2.5 SW x X2.5 SW x X2.5 SW x X2.5 SW x X4 SW x X4 SW x X4 SW x X6 SW x X6 SW x X6 SW x X10 SW x X16 SW x X10 SW x X16 SW x X25 SW x X35 SW x X35 SW x X50 SW x X70 SW x X95 SW x X120 SW x

95 NGFLCGOEU RUBBER INSULATED / POWER Standard VDE 0250 T. 809 (with reference to) bare copper class 6 = extra finely stranded, up from 35 sq class 5 rubber (EPR) 3GI3, halogenfree Screen copper braid, tinned Screen coverage 80 % rubber (CR) 5GM3 VDE /IEC Oil-resistant EN Ozone-resistant yes Maximum permitted conductor temperature 90 C C Application: For the connection of mobile parts of machine tools, conveyor plants and major items of equipment, if the cables is exposed to bends in only one level. For installation in dry, damp and wet areas as well as outdoors. Due to the screening of each single core the cable provides enhanced EMC properties. W x H X1.5 SW x X1.5 SW x X2.5 SW x X4 SW x X6 SW x X10 SW x ELECTRONIC A05RN-F LAN bare copper Application: class 5 = fine stranded rubber EI3 rubber 5GM2 Ozone-resistant Maximum permitted conductor temperature Bending radius, fixed installation Bending radius, moving application Nominal voltage Uo Nominal voltage U VDE /IEC yes 60 C C 4 x DA 5 x DA 300 V 500 V For fixed and flexible connection of electrical appliances at low mechanical stress in dry, damp and wet areas and outdoors. Thanks to the wire designation and the UV- and ozone-resistant outer sheath, the cables are particularly suitable for the connection of roller blind and Venetian blind drives G0.75 SW G0.75 GR COAXIAL

96 POWER / RUBBER INSULATED FABER Jalousie FRNC ELECTRONIC bare copper Application: class 5 = fine stranded FRNC-compound HI1 Material inner sheath halogen-free polyurethan Colour outer sheath black UV-resistant Ozone-resistant Maximum permitted conductor temperature Bending radius, fixed installation VDE /IEC yes yes 70 C C 5 x DA For the fixed and flexible connection of electrical appliances at low mechanical stress in dry, damp and wet areas and outdoors. Thanks to the wire designation and the UV-and ozone-resistant outer sheath, the cables are particularly suitable for the connection of roller blind and Venetian blind drives G0.75 SW NSGAFOEU 1.8/3 kv LAN COAXIAL CPR-performance acc. to EN Eca Standard VDE 0250 T. 602 tinned copper class 5 = fine stranded rubber (EPR) 3GI3, halogenfree rubber (CR) 5GM5 VDE /IEC Ozone-resistant yes Maximum permitted conductor temperature 90 C C temperature, in motion/ C during installation Nominal voltage Uo 1800 V Application: This wire is designed for use in dry rooms, buses and rail-borne vehicles. It is considered to be short circuitproof and earth leakage-proof when used in switching appliances and distributors of up to 1 kv. It is flameretardant and resistant to most oils X1.5 SW X2.5 SW X4 SW X6 SW X10 SW X16 SW X25 SW X35 SW

97 NSGAFOEU 1.8/3 kv RUBBER INSULATED / POWER X50 SW X70 SW X95 SW X120 SW X150 SW X185 SW X240 SW X300 SW X500 SW COAXIAL LAN ELECTRONIC 97

98 POWER / PUR-INSULATED H05BQ-F ELECTRONIC Standard EN Application: bare copper In dry and wet environments as well as outdoors under medium class 5 = fine stranded mechanical stress. For connection of rubber (EPR) EI4 electrical tools on building sites or in polyurethan cold environments. The cable is highly no oil-, abrasion- and impact resistant. Maximum permitted conductor temperature 90 C C Nominal voltage Uo 300 V Nominal voltage U 500 V Core identification colours acc. to VDE 0293 (HD308) HAR yes X0.75 OR X0.75 OR G0.75 OR G0.75 OR G0.75 OR X1 OR G1 OR G1 OR G1 OR LAN H07BQ-F (without filler) COAXIAL Standard EN Application: copper, bare or tinned In dry and wet environments as well as outdoors under medium class 5 = fine stranded mechanical stress. For connection of rubber (EPR) EI4 electrical tools on building sites or in polyurethan cold environments. The cable is highly no oil-, abrasion- and impact resistant. Maximum permitted conductor temperature 90 C C Nominal voltage Uo 450 V Nominal voltage U 750 V Core identification colours acc. to VDE 0293 (HD308) HAR yes X1.5 OR G1.5 OR G1.5 OR G1.5 OR

99 H07BQ-F (without filler) PUR-INSULATED / POWER X2.5 OR G2.5 OR G2.5 OR G2.5 OR G4 OR G4 OR G4 OR G6 OR G6 OR G10 OR G10 OR G16 OR G16 OR X07BQ-F (without filler) Standard EN Application: copper, bare or tinned In dry and wet environments as well as outdoors under medium class 5 = fine stranded mechanical stress. For connection of rubber (EPR) EI4 electrical tools on building sites or in polyurethan cold environments. The cable is highly no oil-, abrasion- and impact resistant. Maximum permitted conductor temperature 90 C C Nominal voltage Uo 450 V Nominal voltage U 750 V Core identification colours acc. to VDE 0293 (HD 308); more than 5 cores: gn-ye + numbers HAR yes ELECTRONIC LAN COAXIAL G1.5 OR G1.5 OR G2.5 OR G2.5 OR /en/ 99

100 POWER / PUR-INSULATED X07BQ-F (with filler) ELECTRONIC Standard EN Application: copper, bare or tinned In dry and wet environments as well as outdoors under medium class 5 = fine stranded mechanical stress. For connection of rubber (EPR) EI4 electrical tools on building sites or in polyurethan cold environments. The cable is highly no oil-, abrasion- and impact resistant. Maximum permitted conductor temperature 90 C C Nominal voltage Uo 450 V Nominal voltage U 750 V Core identification colours acc. to VDE 0293 (HD308) HAR yes COAXIAL LAN G25 OR G35 OR G50 OR G70 OR G95 OR G25 OR G35 OR G50 OR G70 OR G95 OR G2.5 OR /en/

101 SiD SILICONE INSULATED / POWER CPR-performance acc. to EN Eca tinned copper class 1 = solid silicone rubber VDE /IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 180 C C Bending radius, moving application 6 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V Application: For operation in ambient temperatures above 55 C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distribution boards. ELECTRONIC COAXIAL LAN X0.75 WS X1 SW X1 WS X1.5 BL X1.5 BR X1.5 GG X1.5 SW X1.5 WS X2.5 BL X2.5 BR X2.5 SW

102 POWER / SILICONE INSULATED SiF ELECTRONIC LAN COAXIAL CPR-performance acc. to EN on request tinned copper class 5 = fine stranded silicone rubber VDE /IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 6 x DA Bending radius, moving application 15 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V Application: For operation in ambient temperatures above 55 C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distribution boards X0.5 BL X0.5 SW X0.5 BR X0.5 GR X0.5 WS X0.5 RT X0.75 GR X0.75 WS X0.75 RT X0.75 SW X0.75 BR X0.75 BL X0.75 GG X1 GG X1 SW X1 BR X1 BL X1 GR X1 WS X1 RT X1.5 BL X1.5 GG X1.5 RT X1.5 BR X1.5 SW X1.5 GR X1.5 WS X2.5 GG X2.5 BL X2.5 SW X2.5 RT X2.5 BR X2.5 GR X2.5 WS X4 GG X4 BL X4 SW X4 BR X4 GR X4 WS X4 RT

103 SiF H05SJ-K SILICONE INSULATED / X6 GG X6 BL X6 SW X6 BR X6 GR X6 WS X6 RT X10 BL X10 BR X10 SW X10 GG X16 SW X16 GG X25 SW X25 GG X35 SW X35 GG X50 SW X70 SW X95 SW X120 SW X150 SW X185 SW X240 SW X300 SW POWER ELECTRONIC Standard EN Application: tinned copper class 5 = fine stranded silicone EI2 Covering braided glass fibres Maximum permitted conductor temperature Bending radius, fixed installation Bending radius, single bend Nominal voltage Uo Nominal voltage U VDE /IEC C C 6 x DA 3 x DA 300 V 500 V For operation in ambient temperatures above 55 C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distribution boards X1.5 WS X2.5 WS X4 WS LAN COAXIAL 103

104 POWER / SILICONE INSULATED SiF/GL ELECTRONIC tinned copper Application: class 5 = fine stranded silicone rubber Covering laquered/impregnated glass fibre braid Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 15 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V COAXIAL LAN For operation in ambient temperatures above 55 C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distribution boards X4 WS X6 WS X10 WS X16 WS X25 WS X35 WS X50 WS X70 WS X95 WS X120 WS X150 WS X185 WS X240 WS X300 WS

105 FZLSi SILICONE INSULATED / POWER tinned copper Application: class 5 = fine stranded silicone rubber Halogen-free DIN EN 50267/IEC C Ignition wire for use under heavy transient ambient temperatures. For fixed installation or flexible use in the thermo- and process technology, refrigeration- and air conditioningtechnology X1 RT X1.5 RT X1.5 BL ELECTRONIC 2GTL 13.8/15 kv tinned copper Application: class 5 = fine stranded silicone rubber Covering synthetic yarn, varnish coating with PUR VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC UV-resistant yes Ozone-resistant yes Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 6 x DA This connection cable is primarily used where great flexibility is required and a great thermal stress provided, e.g. transformers, generators, engines etc. For installation indoors and in cable ducts for power plant, industry and distribution networks. The halogenfree coating lends the cable good non-slip properties and abrasionresistance as well as a very good resistance to transformer oil and light fuel oil X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW LAN COAXIAL 105

106 POWER / SILICONE INSULATED 2GTL 13.8/15 kv X95 SW X120 SW X150 SW X185 SW X240 SW SiHF-J ELECTRONIC tinned copper Application: class 5 = fine stranded silicone rubber silicone rubber VDE /IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 5 x DA Bending radius, moving application 15 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V For connection of mobile electrical appliances without mechanical stress at increased ambient temperatures, for example in steelworks, but also at low temperatures. and sheath are resistant to most oils, greases, acids, lyes and oxidants. For fixed installation in mechanically protected conduits. For indoor and outdoor use. LAN COAXIAL X0.75 RT X0.75 RT X0.75 RT X0.75 RT X0.75 RT X0.75 RT X0.75 RT X1 RT X1 RT X1 RT X1 RT X1 RT X1 RT X1 RT X1.5 RT X1.5 RT X1.5 RT X1.5 RT X1.5 RT X1.5 RT X1.5 RT X2.5 RT X2.5 RT X2.5 RT X2.5 RT X2.5 RT X2.5 RT X4 RT X4 RT

107 SiHF-J SiHF-O SILICONE INSULATED / X4 RT X4 RT X6 RT X6 RT X6 RT X6 RT X10 RT X16 RT X25 RT X35 RT X50 RT X70 RT X95 RT X10 RT X16 RT POWER tinned copper Application: class 5 = fine stranded silicone rubber silicone rubber VDE /IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 5 x DA Bending radius, moving application 15 x DA Nominal voltage Uo 300 V Nominal voltage U 500 V ELECTRONIC LAN COAXIAL For connection of mobile electrical appliances without mechanical stress at increased ambient temperatures, for example in steelworks, but also at low temperatures. and sheath are resistant to most oils, greases, acids, lyes and oxidants. For fixed installation in mechanically protected conduits. For indoor and outdoor use X0.75 RT X1 RT X1.5 RT X2.5 RT X4 RT X6 RT

108 POWER / SILICONE INSULATED SiHFC-Si-J/-O ELECTRONIC LAN COAXIAL tinned copper Application: class 5 = fine stranded silicone rubber Material inner sheath silicone rubber Screen copper braid, tinned Screen coverage 85 % silicone rubber VDE /IEC Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 5 x DA Bending radius, moving application 10 x DA For connection of electrical appliances without mechanical stress at increased environmental temperatures, for example in steelworks, but also at low temperatures. and sheath are resistant to most oils, acids, lyes and oxidants. For indoor and outdoor use. The cable is designed for use in EMC-sensitive applications X0.75 RT G0.75 RT G0.75 RT G0.75 RT G0.75 RT G0.75 RT G0.75 RT G0.75 RT X1 RT G1 RT G1 RT G1 RT G1 RT G1 RT G1 RT G1 RT G1 RT X1.5 RT G1.5 RT G1.5 RT G1.5 RT G1.5 RT G1.5 RT G1.5 RT G1.5 RT X2.5 RT G2.5 RT G2.5 RT G2.5 RT G4 RT G4 RT G6 RT G6 RT G10 RT G16 RT G25 RT G35 RT

109 SiHF/GLS-P SILICONE INSULATED / POWER tinned copper Application: class 5 = fine stranded silicone rubber Covering braided glass fibres Armour Radiation resistance Maximum permitted conductor temperature Bending radius, fixed installation Nominal voltage Uo round or flat steel wires, galvanized silicone rubber VDE /IEC x 10exp6 cj/kg 180 C C 10 x DA 300 V For the connection of electrical appliances at high mechanical stress at increased environmental temperatures, for example in steelworks, but also at low temperatures. and sheath are resistant to most oils, greases, acids, lyes and oxidants X0.75 SD G0.75 SD G0.75 SD G0.75 SD G0.75 SD X1 SD G1 SD G1 SD G1 SD G1 SD X1.5 SD G1.5 SD G1.5 SD G1.5 SD G1.5 SD G1.5 SD G1.5 SD G1.5 SD X2.5 SD G2.5 SD G2.5 SD G2.5 SD G2.5 SD G4 SD G4 SD G4 SD G6 SD G6 SD G10 SD G16 SD G25 SD ELECTRONIC LAN COAXIAL 109

110 POWER / SILICONE INSULATED H05SS-F ELECTRONIC Standard EN Application: tinned copper class 5 = fine stranded silicone rubber silicone rubber Colour outer sheath black Maximum permitted conductor temperature Bending radius, fixed installation Nominal voltage Uo Nominal voltage U VDE /IEC C C 4 x DA 300 V 500 V COAXIAL LAN For connection of mobile electrical appliances with low mechanical stress at increased ambient temperatures, for example in steelworks or sauna, but also at low temperatures. and sheath are resistant to most oils, greases, acids, lyes and oxidants. For fixed installation in mechanically protected conduits. For indoor and outdoor use. The sheath has enhanced performance in terms of tearing, breaking and notch strength (EWKF) X0.75 SW G0.75 SW G0.75 SW G0.75 SW X1 SW G1 SW G1 SW G1 SW G1.5 SW X2.5 SW G2.5 SW G2.5 SW

111 H05SS-F (UL) SILICONE INSULATED / POWER Standard EN Application: Specification/Standard HD 525/UL 4476 tinned copper class 5 = fine stranded silicone rubber silicone rubber Colour outer sheath black VDE /IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 180 C C Bending radius, fixed installation 5 x DA For connection of mobile electrical appliances with low mechanical stress at increased ambient temperatures, for example in steelworks or sauna, but also at low temperatures. and sheath are resistant to most oils, greases, acids, lyes and oxidants. For fixed installation in mechanically protected conduits. For indoor and outdoor use. The sheath has enhanced performance in terms of tearing, breaking and notch strength (EWKF) X AWG 16 (02X1.5) SW G AWG 16 (03G1.5) SW G AWG 16 (04G1.5) SW G AWG 16 (05G1.5) SW G AWG 14 (03G2.5) SW G AWG 14 (04G2.5) SW G AWG 14 (05G2.5) SW ELECTRONIC COAXIAL LAN 111

112 POWER / SPECIAL Livz6YYw ELECTRONIC tinned copper Application: class 5 = fine stranded FEP special PVC-compound Maximum permitted conductor temperature Bending radius, fixed installation Nominal voltage Uo Nominal voltage U VDE /IEC C C 7.5 x DA 300 V 500 V Universally applicable: Cable with wide range of applications in electronics, nuclear engineering, aviation, marine and military, heating devices and lighting. The insulation is flame-retardant and heat-resistant. For heavy duty use X0.75 FL TR G0.75 TR G0.75 TR G1.5 TR G1.5 TR G1.5 T TR Li2GYw (SiHYw PV/P) LAN COAXIAL bare copper Application: class 5 = fine stranded As connecting cable between transformer and halogen lamps in low silicone rubber voltage lightning systems. PVC VDE /IEC Maximum permitted conductor temperature 180 C C temperature, in motion/ 5-90 C during installation Bending radius, fixed installation 7.5 x DA Nominal voltage U 24 V Core identification red, blue X1.5 SW X2.5 SW

113 NYL SPECIAL / POWER Standard VDE Application: tinned copper class 5 = fine stranded PVC Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Nominal voltage Uo Nominal voltage U VDE /IEC C C C 4 x DA 5000 V V PVC fluorescent tube cables are suitable for protected laying on plaster, in luminaire housings, relief fittings and in cable ducts of metal to VDE X1.5 GE ELECTRONIC FABER THERM 145 (Single core) tinned copper Application: class 5 = fine stranded cross-linked polyolefincopolymer VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Ozone-resistant yes Maximum permitted conductor temperature 145 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Bending radius, moving application 6 x DA This electron beam cross-linked, halogen-free, insulated wire is used for the connection of lights, heating units and machines in environments with increased temperatures. In addition to a long working life and a high permissible conductor temperature it also ensures an increased current carrying capacity in comparison to conventional cables. Not for installation on ladders or trays. Ship approvals (GL, DNV, LRS, BV) can be provided on request. LAN COAXIAL X0.75 SW X1 SW X1.5 SW X2.5 SW X4 SW

114 POWER / SPECIAL FABER THERM 145 (Single core) ELECTRONIC LAN COAXIAL X6 SW X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW X120 SW FABER THERM 145 tinned copper Application: class 5 = fine stranded cross-linked polyolefincopolymer cross-linked polyolefincopolymer VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Ozone-resistant yes For outdoor use yes Maximum permitted conductor temperature 145 C C temperature, in motion/ C during installation This electron beam cross-linked, halogen-free, insulated wire is used for the connection of lights, heating units and machines in environments with increased temperatures. In addition to a long working life and a high permissible conductor temperature it also ensures an increased current carrying capacity in comparison to conventional cables. Ship approvals (GL, DNV, LRS, BV) can be provided on request X1.5 SW G1.5 SW G1.5 SW G2.5 SW G2.5 SW

115 (N)TMCGCWOEU 12/20 kv TRAILING / POWER Standard VDE (with ref. to) Application: tinned copper class 5 = fine stranded rubber 3GI3 Electrical field control Arrangement of protective conductors Torsion Colour outer sheath UV-resistant Oil-resistant EN inner and outer semiconducting rubber layer copper spiral shield on each core +/- 25 /m rubber (CR) 5GM3 red VDE /IEC yes Single core cables are used in short lengths, e.g. for the connection of switchgear cubicles and for the connection of mobile transformer substations. When laying and during operation, care should be taken to protect them from excessive mechanical stress. The outer semiconducting layer must not be heated before removal X50/16 RT X95/16 RT X150/25 RT X240/25 RT ELECTRONIC (N)TSCGEWOEU MT PLUS 12/20 kv Standard VDE Application: tinned copper class 5 = fine stranded rubber 3GI3 Electrical field control Central filler Core wrapping Arrangement of protective conductors Material inner sheath Torsion protection Torsion inner and outer semiconducting rubber layer semiconductive compound on polyester support semiconductive tape split into three elements in outer interstices rubber GM1b polyester braid +/- 25 /m rubber (CR) 5GM3 Flexible medium voltage reeling cable for high and extreme mechanical stress, e.g. torsional stress, deflection and high reeling speed. Other applications have to be agreed with Faber otherwise warranty may become void X35 + 3X25/3 RT X50 + 3X25/3 RT X95 + 3X50/3 RT X X70/3 RT LAN COAXIAL 115

116 NOTES COAXIAL LAN ELECTRONIC POWER 116

117 POWER ELECTRONIC S INSTALLATION 118 I-YY 118 I-Y(St)Y... Lg 118 Fire signalisation cable 119 J-H(ST)H 120 J-H(St)H Fire signalisation cable 121 J-2Y(St)Y... St III Bd 121 J-2Y(St)H... St III Bd 122 SUBSCRIBER LINE 123 A-2Y(L)2Y A-2Y(L)2Y A-2YF(L)2Y A-2YF(L)2Y A-02YSF(L)2Y... St III Bd 127 A-2YF(L)2YB2Y... St III Bd 127 A-02YS(St)(Zg)2Y A-02YSOF(L)2Y AJ-Y(St)YDY Bd 129 A-Y(St)Yoe 129 LAN INSTRUMENTATION 130 RD-Y(St)Y 130 RD-H(St)H 131 RD-Y(St)Yv 131 R E -2 X ( S t ) Y v - fl 132 RE-2X(St)Yv-fl PiMF 133 RE-2Y(St)Yv 0.5 sq 134 RE-2Y(St)Yv 0.75 sq 135 RE-2Y(St)Yv 1.3 sq 136 RD-YwCYw 137 INDUSTRIAL ELECTRONICS 138 JE-Y(St)Y 138 JE-Y(St)Yv 139 JE-Y(St)Y... FR 140 JE-LiYCY 141 JE-LiHCH 142 COAXIAL PVC-INSULATED 143 YR 143

118 POWER / S INSTALLATION I-YY CPR-performance acc. to EN Eca Standard VDE 0815 bare copper class 1 = solid PVC TI1 Stranding unit quads Stranding bunches PVC TM1 Colour outer sheath grey RAL 7032 VDE /IEC C temperature, in motion/ C during installation Application: Preferably for telecounication installations inside buildings in dry and humid rooms, but also for permanent installation at external walls if protected from sunlight. These cables are not approved for high-voltage applications. ELECTRONIC X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR LAN I-Y(St)Y... Lg COAXIAL CPR-performance acc. to EN Eca Standard VDE 0815 bare copper class 1 = solid PVC TI1 Stranding unit pair Stranding layers Screen over strand foil Drain wire yes PVC TM1 Colour outer sheath grey RAL 7032 VDE /IEC Application: Preferably for telecounication installations inside buildings in dry and humid rooms, but also for permanent installation at external walls if protected from sunlight. These cables are not approved for high-voltage applications X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR

119 I-Y(St)Y... Lg S INSTALLATION / POWER X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR ELECTRONIC Fire signalisation cable LAN CPR-performance acc. to EN Stranding unit Stranding Screen over strand Drain wire Colour outer sheath on request bare copper class 1 = solid PVC TI1 pair layers foil yes PVC TM1 red VDE /IEC C Application: For the connection of telecounication units inside buildings in and under plaster in dry and wet rooms. Also suitable for installation outdoors if the cable is protected from sunlight. By the special sheath imprint -Brandmeldekabel- this cable is particularly designed for the use in fire signalisation systems X2X0.8 RT X2X0.8 RT X2X0.8 RT COAXIAL

120 POWER / S INSTALLATION Fire signalisation cable X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT J-H(ST)H ELECTRONIC CPR-performance acc. to EN Cca Standard VDE 0815 bare copper FRNC-compound HI1 Screen plastic coated aluminium foil + solid copper drain wire FRNC-compound HM1 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C Bending radius, fixed installation 7.5 x DA Coupling K1 300 pf Application: Low-smoke, zero-halogen counication cable with improved flame-retardance. Primarily for use in buildings with a high concentration of people or material assets. For the connection of counication units indoors in wet and dry rooms on and under plaster. For outdoor installation the cable must be protected from sunlight. LAN COAXIAL X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR

121 S INSTALLATION / J-H(St)H Fire signalisation cable POWER CPR-performance acc. to EN Standard Screen Drain wire Cca VDE 0815 (with ref. to) bare copper FRNC-compound HI1 foil yes FRNC-compound HM1 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C Bending radius, fixed installation 7.5 x DA Application: Low-smoke, zero-halogen counication cable with improved flame-retardance. Primarily for use in buildings with a high concentration of people or material assets. For connection of counication units indoors, in wet and dry rooms on and under plaster. By the special sheath printing -Brandmeldekabel- this cable is particularly designed for the use in fire signalisation systems X2X0.8 RT X2X0.8 RT ELECTRONIC J-2Y(St)Y... St III Bd bare copper Application: class 1 = solid For connection of computer units, ISDN-sub-units and -devices and polyethylene for data transmission. Suitable Stranding unit quads for transmission of analogue and Stranding bunches digital signals up to 16 Mbit/s. For Screen over strand foil installation in dry and wet rooms, on Drain wire yes and under plaster. PVC Colour outer sheath grey RAL 7032 VDE /IEC C temperature, in motion/ during installation C X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR LAN COAXIAL 121

122 POWER / S INSTALLATION J-2Y(St)Y... St III Bd X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR J-2Y(St)H... St III Bd ELECTRONIC LAN COAXIAL bare copper Application: polyethylene Halogen-free and flame-retardant ISDN-system cable, for connection of Stranding bunched star-quads telecounication an IT-components Screen foil up to 16 Mbit/s (cat. 3). For installation Drain wire yes indoors, in and under plaster, in dry FRNC-compound HM2 and wet rooms. VDE /IEC Smoke density DIN EN 61034/IEC C Impedance 100 Ohm resistance 5000 MOhmxkm Transfer impedance 200 Ohm/km X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR X2X0.6 GR

123 A-2Y(L)2Y 0.6 SUBSCRIBER LINE / POWER Standard VDE 0816 Application: bare copper For fixed installation indoors, outdoors, in the ground, in water and solid in conrete. polyethylene 2YI1 Stranding unit quads Stranding bunched star-quads Screen over strand foil polyethylene 2YM1 Bonded sheath yes Transversely watertight yes Longitudinally watertight no Colour outer sheath black X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW ELECTRONIC COAXIAL LAN 123

124 POWER / SUBSCRIBER LINE A-2Y(L)2Y 0.8 ELECTRONIC Standard VDE 0816 Application: bare copper For fixed installation indoors, outdoors, in the ground, in water and solid in conrete. polyethylene 2YI1 Stranding unit quads Stranding bunched star-quads Screen over strand foil polyethylene 2YM1 Bonded sheath yes Transversely watertight yes Longitudinally watertight no Colour outer sheath black COAXIAL LAN X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW

125 A-2YF(L)2Y 0.6 SUBSCRIBER LINE / POWER Standard VDE 0816 Application: bare copper For fixed installation indoors, outdoors, in the ground, in water and solid in conrete. polyethylene 2YI1 Stranding unit quads Stranding bunched star-quads Screen over stranding unit foil polyethylene 2YM1 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW X2X0.6 SW ELECTRONIC COAXIAL LAN 125

126 POWER / SUBSCRIBER LINE A-2YF(L)2Y 0.8 ELECTRONIC LAN Standard VDE 0816 Application: bare copper For fixed installation indoors, outdoors, in the ground, in water and solid in conrete. polyethylene 2YI1 Stranding unit quads Stranding bunched star-quads Screen over stranding unit foil polyethylene 2YM1 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes Colour outer sheath black COAXIAL X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW

127 A-02YSF(L)2Y... St III Bd SUBSCRIBER LINE / POWER Standard VDE 0816 Application: bare copper Subscriber line cable in local networks, for data and voice class 1 = solid transmission. For installation foam skin outdoors, in the ground and in ducts. polyethylene Bonded sheath yes UV-resistant yes C Bending radius, fixed installation 7.5 x DA resistance 5000 MOhmxkm Coupling K1 400 pf Coupling K pf X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW ELECTRONIC A-2YF(L)2YB2Y... St III Bd LAN Standard VDE 0816 (with ref. to) Application: bare copper For fixed installation indoors, outdoors, in the ground, in water and solid in conrete. polyethylene 2YI1 Armour steel tape, galvanized polyethylene 2YM2 Bonded sheath yes Transversely watertight yes Longitudinally watertight yes UV-resistant yes C temperature, in motion/ C during installation X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW COAXIAL

128 POWER / SUBSCRIBER LINE A-02YS(St)(Zg)2Y 0.5 ELECTRONIC bare copper Application: solid foam skin Stranding bunched star-quads Screen foil Strength member temperature, in motion/ during installation Bending radius, fixed installation resistance in outer sheath embedded glass yarns polyethylene no C C 5 x DA 1000 MOhmxkm Self-supporting cables are preferably used for telecounication installations. They are designed for self-supporting aerial outdoor installations up to a support distance of 50 m, but, as an exception, they may be buried in ground over short distances. If necessary, they have to be protected mechanically X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW LAN A-02YSOF(L)2Y 0.8 COAXIAL Standard VDE 0816 Application: bare copper For use as a connection cable in local voice and data transmission solid networks. For installation outdoors, in foam-pe the ground, in cable ducts and cable polyethylene pipes. Bonded sheath yes Transversely watertight yes Longitudinally watertight yes UV-resistant yes C Bending radius, fixed installation 7.5 x DA resistance 5000 MOhmxkm X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW

129 AJ-Y(St)YDY Bd SUBSCRIBER LINE / POWER Standard VDE 0816 Application: bare copper solid PVC Stranding unit pair Stranding bunches Screen copper wires Screen over strand Colour outer sheath plastic coated Al-foil + solid copper drain wire, tinned PVC black VDE /IEC C For signal transmission in telecounication systems or measurement, control and data systems where interference or disruption from high-voltage systems is to be expected. For permanent installation indoors and outdoors as well as in the ground. The instructions in VDE 0891 T. 6 and VDE 0845 T. 1 must be complied with X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW ELECTRONIC A-Y(St)Yoe LAN Standard VDE 0816 Application: tinned copper class 1 = solid PVC Stranding unit core Stranding layers Screen over stranding unit plastic coated Al-foil + copper drain wire, tinned Drain wire yes special PVC-compound Colour outer sheath black UV-resistant yes Oil-resistant EN These data transmission cables are used for connections between petrol pumps and the cash register respective price display. The cable is largely oil- and fuel-resistant. For fixed installation in buildings, outdoors as well as in ground without mechanical stress. COAXIAL X0.75 SW X0.75 SW

130 POWER / INSTRUMENTATION RD-Y(St)Y ELECTRONIC LAN CPR-performance acc. to EN Suitable for Maxi-Termi- Point applications Screen over strand Drain wire Colour outer sheath temperature, in motion/ during installation Eca bare copper class 2, 7-wired construction PVC yes COAXIAL foil yes PVC grey VDE /IEC C C Application: In measuring and control circuits of industrial installations for transfer of analogue and digital data up to 10 khz. For fixed installation inside buildings. The version with blue outer sheath is suitable for application in intrinsically safe circuits X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL

131 RD-H(St)H INSTRUMENTATION / POWER bare copper Application: class 2 = stranded In measuring and control circuits of industrial installations for transfer FRNC-compound HI1 of analogue and digital data up to Screen foil 10 khz. For fixed installation inside Drain wire yes buildings. FRNC-compound HM1 Colour outer sheath grey VDE /IEC (Kat. C) Halogen-free DIN EN 50267/IEC C Bending radius, fixed installation 7.5 x DA Nominal voltage U 225 V X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR ELECTRONIC RD-Y(St)Yv LAN bare copper Application: class 2, 7-wired construction PVC Screen plastic coated aluminium foil + solid copper drain wire Drain wire yes PVC, enforced Colour outer sheath grey RAL 7032 VDE /IEC C temperature, in motion/ C during installation Bending radius, fixed installation 7.5 x DA resistance 100 MOhmxkm In measuring and control circuits of industrial installations for transfer of analogue and digital data up to 10 khz. For fixed installation inside buildings, outdoors and for direct burial. The cable may be used for Maxi-Termi-Point connections X2X0.5 GR X2X0.5 GR COAXIAL

132 POWER / INSTRUMENTATION RE-2X(St)Yv-fl ELECTRONIC LAN COAXIAL Standard EN Application: bare copper For data counication with transmission rates up to 200 kbit/s in class 2, 7-wired construction MSR- and EDP systems. Transmission XLPE characteristics are guaranteed by Stranding unit pair high-quality stranding and screening. Stranding pairs in layers For fixed installation in dry and damp Screen over strand foil areas as well as in the ground. Drain wire yes PVC VDE /IEC (Kat. C) C Bending radius, fixed installation 7.5 x DA X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X1.3 BL X3X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X1.3 SW X3X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW

133 RE-2X(St)Yv-fl PiMF INSTRUMENTATION / POWER Standard EN Application: bare copper For data counication with transmission rates up to 200 kbit/s in strand, 7-wired construction MSR- and EDP systems. Transmission XLPE characteristics are guaranteed by Screen over stranding unit foil high-quality stranding and screening. Screen over strand foil For fixed installation in dry and damp Drain wire yes areas, outdoors and direct burial in the ground. PVC, enforced VDE /IEC (Kat. C) C temperature, in motion/ C during installation Bending radius, fixed installation 7.5 x DA X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL ELECTRONIC LAN COAXIAL 133

134 POWER / INSTRUMENTATION RE-2Y(St)Yv 0.5 sq ELECTRONIC LAN CPR-performance acc. to EN Suitable for Maxi-Termi- Point applications Screen temperature, in motion/ during installation Bending radius, fixed installation resistance on request bare copper class 2, 7-wired construction polyethylene yes plastic coated aluminium foil + solid copper drain wire PVC TM1 VDE /IEC C C 7.5 x DA COAXIAL 5 MOhmxkm Application: For data counication with transmission rates up to 200 kbit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in the ground X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL

135 RE-2Y(St)Yv 0.75 sq INSTRUMENTATION / POWER CPR-performance acc. to EN Suitable for Maxi-Termi- Point applications Screen temperature, in motion/ during installation Bending radius, fixed installation resistance on request bare copper class 2, 7-wired construction polyethylene yes plastic coated aluminium foil + solid copper drain wire PVC TM1 VDE /IEC C C 7.5 x DA 5 MOhmxkm Application: For data counication with transmission rates up to 200 kbit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in the ground X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 SW X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL X2X0.75 BL ELECTRONIC LAN COAXIAL 135

136 POWER / INSTRUMENTATION RE-2Y(St)Yv 1.3 sq ELECTRONIC LAN CPR-performance acc. to EN Suitable for Maxi-Termi- Point applications Screen temperature, in motion/ during installation Bending radius, fixed installation resistance on request bare copper class 2, 7-wired construction polyethylene yes plastic coated aluminium foil + solid copper drain wire PVC TM1 VDE /IEC C C 7.5 x DA COAXIAL 5 MOhmxkm Application: For data counication with transmission rates up to 200 kbit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in the ground X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 SW X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL X2X1.3 BL

137 RD-YwCYw INSTRUMENTATION / POWER bare copper Application: class 2, 7-wired construction PVC YI 8 Screen copper braid Screen coverage 80 % PVC YM 4 Colour outer sheath grey VDE /IEC C temperature, in motion/ C during installation Bending radius, fixed installation 7.5 x DA resistance 100 MOhmxkm For data counication with transmission rates up to 200 kbit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas with high environmental temperatures X2X0.5 GR X2X0.5 GR ELECTRONIC COAXIAL LAN 137

138 POWER / INDUSTRIAL ELECTRONICS JE-Y(St)Y ELECTRONIC LAN CPR-performance acc. to EN Eca Standard VDE 0815 bare copper solid PVC YI3 Core wrapping plastic foil Screen plastic coated aluminium foil + solid copper drain wire PVC TM1 Colour outer sheath grey RAL 7032, alternatively blue RAL 5015 VDE /IEC C Bending radius, fixed installation 7.5 x DA COAXIAL Application: For signal transmission between electronic devices, in computer systems, process control units office equipment. For installation in dry and wet rooms X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL

139 JE-Y(St)Yv INDUSTRIAL ELECTRONICS / POWER bare copper Application: class 1 = solid PVC YI3 Screen Colour outer sheath Bending radius, fixed installation Nominal voltage U Core identification plastic coated aluminium foil + solid copper drain wire PVC, enforced grey VDE /IEC C 7.5 x DA 225 V colours + rings For signal transmission between electronic devices, in computer systems, process control units or office equipment. For installation in dry and wet rooms. The sheath is resistant to most frequently used oils X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 SW X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL ELECTRONIC COAXIAL LAN 139

140 POWER / INDUSTRIAL ELECTRONICS JE-Y(St)Y... FR ELECTRONIC LAN bare copper Application: class 1 = solid For signal transmission between electronic devices, in computer PVC YI1 systems, process control units office Screen foil equipment. For installation in dry and special PVC-compound wet rooms. Colour outer sheath grey VDE /IEC (Kat. C) C temperature, in motion/ C during installation Bending radius, fixed installation 7.5 x DA Bending radius, moving application 15 x DA resistance 100 MOhmxkm COAXIAL X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 GR X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL X2X0.8 BL

141 JE-LiYCY INDUSTRIAL ELECTRONICS / POWER Standard VDE 0815 Application: bare copper For signal transmission between electronic devices, in computer strand, 7-wired construction systems, process control or office PVC equipment units with increased Screen copper braid electromagnetic compatibility PVC requirements. For installation in dry Colour outer sheath grey and wet rooms. VDE /IEC C Bending radius, fixed installation 7.5 x DA resistance 20 MOhmxkm Specific inductivity 0.65 mh/km X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL X2X0.5 BL ELECTRONIC LAN COAXIAL 141

142 POWER / INDUSTRIAL ELECTRONICS JE-LiHCH ELECTRONIC bare copper Application: strand, 7-wired construction FRNC-compound HI1 Screen copper braid Screen coverage 70 % FRNC-compound HM2 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C temperature, in motion/ C during installation Bending radius, fixed installation 7.5 x DA COAXIAL LAN For signal transmission between electronic devices, in computer systems, process control units or office equipment with increased electromagnetic compatibility requirements X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR

143 YR PVC-INSULATED / POWER bare copper Application: class 1 = solid For fixed installation on or under plaster. Core identification: bk, bu, bn, PVC ye, gn, vt, wh, tr, gy PVC VDE /IEC C Bending radius, fixed installation 7.5 x DA Nominal voltage U 100 V X0.8 WS X0.8 WS X0.8 WS X0.8 WS X0.8 WS X0.8 WS X0.8 WS X0.8 WS X0.8 WS ELECTRONIC COAXIAL LAN 143

144 NOTES COAXIAL LAN ELECTRONIC POWER 144

145 POWER ELECTRONIC ELECTRONIC CONTROL 146 YSLY-JZ 146 YSLY-OZ 148 YSLY-JB 149 YSLY-OB 150 YSLYCY-JZ 151 YSLYCY-OZ 152 YSLYCY-JB 153 YSLCY-JZ 154 YSLCY-OZ 155 H05VV5-F 155 H05VVC4V5-K 156 YSLY-JZ YSLY-OZ YSLYCY-JZ YSLYCY-OZ YSL(St)CYv 161 HSLH-JZ 162 HSLH-OZ 163 HSLCH-JZ 164 HSLCH-OZ 165 YSLYSY-JZ 165 YSLYSY-OZ 166 FABER 100 P 167 FABER 100 F-CP 168 H07VVH6-F 169 ELECTRONIC 170 LiYY 170 LiYY/EB 171 LiYCY 172 LiYCY/EB 174 LiYCY/EB TP 175 LiHCH 175 Li2YCYv 176 BUS 178 DRAG CHAIN 181 FABER EFK Li9YC11Y (Drag chain cable) 181 FABER EFK Single core 12Y11Y (Drag chain cable) 182 FABER EFK Single core 12YC11Y (Drag chain cable) 183 FABER EFK 300 P (Drag chain cable) 184 FABER EFK 300 CP (Drag chain cable) 185 FABER EFK 310 Y (Drag chain cable) 186 FABER EFK 310 CY (Drag chain cable) 188 FABER EFK Feedback-CP Indramat (Drag chain cable) 189 FABER EFK Feedback-CP Siemens (Drag chain cable) 190 FABER EFK Servo-CP Indramat (Drag chain cable) 191 FABER EFK Servo-CP Siemens (Drag chain cable) 192 LAN COAXIAL SPECIAL 193 Li2YCY PiMF 193

146 POWER ELECTRONIC / CONTROL YSLY-JZ ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC TI1 Stranding unit core PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Application: Universally applicable: Flexible power, process control and instrumentation cable for industrial applications and mechanical engineering for indoor applications. For installation in dry and damp rooms. The cable is resistant to most usual chemicals, oil and grease. Not suitable for constant motion X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR

147 YSLY-JZ CONTROL / ELECTRONIC X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X4 GR X4 GR X4 GR X4 GR X6 GR X6 GR X6 GR X6 GR X10 GR X10 GR X10 GR X10 GR X16 GR X16 GR X16 GR X16 GR X25 GR X25 GR X35 GR X35 GR X50 GR X50 GR POWER LAN COAXIAL ELECTRONIC 147

148 POWER ELECTRONIC / CONTROL YSLY-OZ ELECTRONIC LAN COAXIAL CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC TI1 Stranding unit core PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Application: Universally applicable: Flexible power, process control and instrumentation cable for industrial applications and mechanical engineering for indoor applications. For installation in dry and damp rooms. The cable is resistant to most usual chemicals, oil and grease. Not suitable for constant motion X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR

149 YSLY-JB CONTROL / ELECTRONIC POWER CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC TI1 Stranding unit core PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Application: Universally applicable: Flexible power, process control and instrumentation cable for industrial applications and mechanical engineering for indoor applications. For installation in dry and damp rooms. The cable is resistant to most usual chemicals, oil and grease. Not suitable for constant motion X0.5 GR X0.5 GR X0.5 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR X2.5 GR X4 GR X4 GR X6 GR X6 GR X10 GR X10 GR X16 GR X16 GR X25 GR X25 GR X25 GR X35 GR X35 GR X35 GR X50 GR X50 GR X70 GR X95 GR X120 GR ELECTRONIC LAN COAXIAL 149

150 POWER ELECTRONIC / CONTROL YSLY-OB ELECTRONIC CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC TI1 Stranding unit core PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA COAXIAL LAN Application: Universally applicable: Flexible power, process control and instrumentation cable for industrial applications and mechanical engineering for indoor applications. For installation in dry and damp rooms. The cable is resistant to most usual chemicals, oil and grease. Not suitable for constant motion X0.5 GR X0.5 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1.5 GR X1.5 GR

151 YSLYCY-JZ CONTROL / ELECTRONIC POWER CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC YI2 Material inner sheath PVC Screen copper braid, tinned Screen coverage 70 % PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C Application: Universally applicable: Flexible power, process control and instrumentation cable for industry and machinery environment with increased electromagnetic compatibility requirements for indoor applications. For installation in dry and damp rooms. The cable is oil-resistant X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X4 GR X4 GR X6 GR X6 GR X10 GR X10 GR X10 GR X16 GR X16 GR X25 GR X25 GR ELECTRONIC LAN COAXIAL

152 POWER ELECTRONIC / CONTROL YSLYCY-OZ CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC YI2 Material inner sheath PVC Screen copper braid, tinned Screen coverage 70 % PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C Application: Universally applicable: Flexible power, process control and instrumentation cable for industry and machinery environment with increased electromagnetic compatibility requirements for indoor applications. For installation in dry and damp rooms. The cable is oil-resistant. ELECTRONIC COAXIAL LAN X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR

153 YSLYCY-JB CONTROL / ELECTRONIC POWER CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC YI2 Material inner sheath PVC Screen copper braid, tinned Screen coverage 70 % PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Maximum permitted conductor temperature 70 C C Application: Universally applicable: Flexible power, process control and instrumentation cable for industry and machinery environment with increased electromagnetic compatibility requirements for indoor applications. For installation in dry and damp rooms. The cable is oil-resistant X4 GR X6 GR X10 GR X16 GR X25 GR X35 GR X50 GR X70 GR X95 GR X120 GR COAXIAL LAN ELECTRONIC 153

154 POWER ELECTRONIC / CONTROL YSLCY-JZ CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC Screen copper braid, tinned Screen coverage 70 % PVC Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C C Application: Optimized control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements for indoor applications. The inner sheath has been replaced by a separating foil, hence diameter, bending radius and weight are less. For installation in dry and damp rooms. The cable is resistant to most coonly used chemicals, oil and grease. ELECTRONIC LAN COAXIAL X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X4 GR X6 GR X10 GR X16 GR X25 GR X35 GR X50 GR

155 YSLCY-OZ CONTROL / ELECTRONIC POWER CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC Screen copper braid, tinned Screen coverage 70 % PVC Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C C Application: Optimized control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements for indoor applications. The inner sheath has been replaced by a separating foil, hence diameter, bending radius and weight are less. For installation in dry and damp rooms. The cable is resistant to most coonly used chemicals, oil and grease. H05VV5-F X0.75 GR X0.75 GR X0.75 GR X1 GR X1.5 GR X2.5 GR ELECTRONIC LAN CPR-performance acc. to EN Eca Standard EN bare copper class 5 = fine stranded PVC TI2 PVC TM5 Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 60 C C temperature, in motion/ 5-50 C during installation Application: Flexible power, process control and instrumentation cable for industry and machinery environment for indoor applications. The cable is resistant to most coonly used chemicals, oil and grease. /en/ G0.5 GR G0.5 GR G0.5 GR G0.5 GR COAXIAL

156 POWER ELECTRONIC / CONTROL H05VV5-F ELECTRONIC H05VVC4V5-K G0.5 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR LAN COAXIAL CPR-performance acc. to EN Eca Standard EN bare copper class 5 = fine stranded PVC YI2 Material inner sheath PVC Screen copper braid, tinned Screen coverage 70 % PVC TM2 Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN Application: Universally applicable: Flexible power, process control and instrumentation cable for industry and machinery environment with increased electromagnetic compatibility requirements for indoor applications. The cable is oil-resistant G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G1 GR

157 H05VVC4V5-K CONTROL / ELECTRONIC POWER G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR YSLY-JZ 600 ELECTRONIC CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC special PVC-compound Colour outer sheath black VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Application: Flexible power, process control and instrumentation cable for industry, machinery and outdoor environment. The cable is resistant to UVirradiation, to most coonly used chemicals and to oil and grease. Not suitable for constant motion. LAN COAXIAL X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X1 SW X1 SW

158 POWER ELECTRONIC LAN ELECTRONIC / CONTROL YSLY-JZ X1 SW X1 SW X1 SW X1 SW X1 SW X1 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X4 SW X4 SW X4 SW X6 SW X6 SW X6 SW X10 SW X10 SW X10 SW X16 SW X16 SW X16 SW X25 SW X35 SW X50 SW X50 SW X70 SW X95 SW X95 SW X120 SW COAXIAL 158

159 YSLY-OZ 600 CONTROL / ELECTRONIC POWER YSLYCY-JZ 600 CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC special PVC-compound Colour outer sheath black VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Application: Flexible power, process control and instrumentation cable for industry, machinery and outdoor environment. The cable is resistant to UVirradiation, to most coonly used chemicals and to oil and grease. Not suitable for constant motion X0.75 SW X1 SW X1.5 SW X2.5 SW ELECTRONIC LAN CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC Material inner sheath PVC Screen copper braid, tinned Screen coverage 70 % special PVC-compound Colour outer sheath black VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C Application: Flexible power, process control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements. The cable is resistant to UV-irradiation, to most coonly used chemicals and to oil and grease. For indoor and outdoor application. COAXIAL /en/ X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW X0.75 SW

160 POWER ELECTRONIC / CONTROL YSLYCY-JZ 600 ELECTRONIC LAN COAXIAL X0.75 SW X1 SW X1 SW X1 SW X1 SW X1 SW X1 SW X1 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X1.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X2.5 SW X4 SW X4 SW X6 SW X6 SW X6 SW X10 SW X10 SW X16 SW X16 SW X25 SW X35 SW X50 SW X70 SW

161 YSLYCY-OZ 600 CONTROL / ELECTRONIC POWER CPR-performance acc. to EN Eca bare copper class 5 = fine stranded PVC Material inner sheath PVC Screen copper braid, tinned Screen coverage 70 % special PVC-compound Colour outer sheath black VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C Application: Flexible power, process control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements. The cable is resistant to UV-irradiation, to most coonly used chemicals and to oil and grease. For indoor and outdoor application. 2YSL(St)CYv X0.75 SW X1 SW X1.5 SW ELECTRONIC bare copper Application: class 5 = fine stranded polyethylene Screen aluminium foil + copper braid, tinned Screen coverage 75 % PVC, enforced Colour outer sheath black VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation This cable was specifically developed for the EMC-compliant connection of frequency converters. For uses with medium mechanical strain with permanent installation and occasional motion indoors and outdoors, but not in the ground. The version with the three-stranded protective conductor is thinner, lighter and distinguished by improved EMC-properties. The cable is largely oil-resistant. LAN COAXIAL /en/ X X0.25 SW X X0.5 SW X4 + 3X0.75 SW X6 + 3X1 SW X10 + 3X1.5 SW X16 + 3X2.5 SW

162 POWER ELECTRONIC / CONTROL 2YSL(St)CYv ELECTRONIC X25 + 3X4 SW X35 + 3X6 SW X50 + 3X10 SW X70 + 3X10 SW X95 + 3X16 SW X X16 SW X X25 SW X X35 SW X X50 SW X1.5 SW X2.5 SW X4 SW X6 SW X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW X120 SW X150 SW X185 SW X240 SW HSLH-JZ LAN COAXIAL bare copper Application: class 5 = fine stranded Halogen-free and LSOH control cable for multiple purposes in control and FRNC-compound HI2 measurement circuits indoors. The FRNC-compound HM2 cable is to a large extent resistant to Colour outer sheath grey RAL 7001 oil and grease. VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 15 x DA X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR

163 HSLH-JZ CONTROL / ELECTRONIC X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X4 GR X4 GR X6 GR X10 GR X16 GR X25 GR X35 GR POWER ELECTRONIC HSLH-OZ bare copper Application: class 5 = fine stranded Halogen-free and LSOH control cable for multiple purposes in control and FRNC-compound HI2 measurement circuits indoors. The FRNC-compound HM2 cable is to a large extent resistant to Colour outer sheath grey RAL 7001 oil and grease. VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 15 x DA X0.75 GR X1 GR X1.5 GR X2.5 GR LAN COAXIAL 163

164 POWER ELECTRONIC / CONTROL HSLCH-JZ ELECTRONIC LAN COAXIAL bare copper strand Application: class 5 = fine stranded FRNC-compound HI2 Core wrapping plastic foil Screen copper braid, tinned Screen coverage 70 % FRNC-compound HM2 Colour outer sheath grey RAL 7001 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Oil-resistant yes LSOH control cable for multiple purposes in control and measurement circuits with specific EMC (electromagnetic compatibility) requirements. For indoor use only. The cable is to a large extent resistant to oil and grease X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X2.5 GR X4 GR X4 GR X6 GR X6 GR X10 GR X10 GR X16 GR X25 GR X35 GR X50 GR X70 GR X95 GR

165 HSLCH-OZ CONTROL / ELECTRONIC POWER bare copper strand Application: class 5 = fine stranded FRNC-compound HI2 Core wrapping plastic foil Screen copper braid, tinned Screen coverage 70 % FRNC-compound HM2 Colour outer sheath grey RAL 7001 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Oil-resistant yes LSOH control cable for multiple purposes in control and measurement circuits with specific EMC (electromagnetic compatibility) requirements. For indoor use only. The cable is to a large extent resistant to oil and grease. YSLYSY-JZ X0.75 GR X1 GR X1.5 GR ELECTRONIC CPR-performance acc. to EN Material inner sheath Colour outer sheath Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Eca bare copper class 5 = fine stranded PVC YI2 PVC TM2 PVC TM2 transparent VDE /IEC C C C 6 x DA Application: Steel wire-reinforced, universal measurement and control cable in mechanical and plant engineering indoors. The cable is largely oilresistant. Not suitable for constant motion. LAN COAXIAL /en/ X0.75 TR X0.75 TR X0.75 TR X0.75 TR X0.75 TR

166 POWER ELECTRONIC / CONTROL YSLYSY-JZ ELECTRONIC YSLYSY-OZ X0.75 TR X0.75 TR X1 TR X1 TR X1 TR X1 TR X1 TR X1 TR X1 TR X1.5 TR X1.5 TR X1.5 TR X1.5 TR X1.5 TR X1.5 TR X1.5 TR X2.5 TR X2.5 TR X2.5 TR X2.5 TR X4 TR X4 TR X4 TR X6 TR X6 TR X6 TR X10 TR X10 TR X16 TR X16 TR LAN COAXIAL CPR-performance acc. to EN Material inner sheath Colour outer sheath Maximum permitted conductor temperature temperature, in motion/ during installation Bending radius, fixed installation Eca bare copper class 5 = fine stranded PVC YI2 PVC TM2 PVC TM2 transparent VDE /IEC C C C 6 x DA Application: Steel wire-reinforced, universal measurement and control cable in mechanical and plant engineering indoors. The cable is largely oilresistant. Not suitable for constant motion X0.5 TR X0.75 TR X1 TR X1.5 TR X2.5 TR

167 FABER 100 P CONTROL / ELECTRONIC POWER bare copper Application: class 5 = fine stranded In dry and wet environment as well as outdoors under medium special PVC-compound mechanical stress. For the connection polyurethan of electrical tools with improved oil-, Colour outer sheath grey RAL 7001 abrasion- and impact-resistance. VDE /IEC Oil-resistant EN Ozone-resistant DIN EN (A) Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA X0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR X1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR X1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR X2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G4 GR G4 GR LAN COAXIAL ELECTRONIC 167

168 ELECTRONIC / CONTROL POWER FABER 100 F-CP ELECTRONIC LAN COAXIAL bare copper Application: class 5 = fine stranded special PVC-compound Screen copper braid Screen coverage 85 % polyurethan Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN Ozone-resistant yes Maximum permitted conductor temperature 70 C C Robust PUR control cable distinguished by high abrasionresistance and notch-tensile strength. The high resistance to oil and coolants enables applications in mechanical and plant engineering, mills and steelworks. For medium mechanical strain without tensile stress or forced guidance. The structure without inner jacket ensures space-saving installation indoors and outdoors X0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR X1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR X1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR X2.5 GR G2.5 GR G2.5 GR G2.5 GR

169 H07VVH6-F CONTROL / ELECTRONIC POWER Standard VDE Application: bare copper PVC-insulated flat cables are used as trailing cable for crane installations, class 5 = fine stranded floor conveyer systems and shelf PVC YI2 control units. Max. suspension length PVC TM2 35 m. VDE /IEC Oil-resistant EN Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Nominal voltage Uo 450 V Nominal voltage U 750 V W x H G1.5 SW x G1.5 SW x G1.5 SW x G1.5 SW x G1.5 SW x G1.5 SW x G1.5 SW x G1.5 SW x G1.5 SW x G2.5 SW x G2.5 SW x G2.5 SW x G2.5 SW x G2.5 SW x G2.5 SW x G4 SW x G6 SW x G10 SW x G16 SW x G25 SW x G35 SW x G50 SW x G70 SW x G4 SW x G6 SW x G10 SW x G16 SW x G4 SW x G6 SW x LAN COAXIAL ELECTRONIC 169

170 POWER ELECTRONIC / ELECTRONIC LiYY ELECTRONIC LAN COAXIAL bare copper Application: class 5 = fine stranded For signal transmission between electronic devices, in computer PVC systems, process control units or Stranding unit core office equipment. PVC VDE /IEC Oil-resistant EN C temperature, in motion/ C during installation resistance 100 MOhmxkm Specific inductivity 0.7 mh/km Nominal voltage Uo 250 V X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.75 GR X0.75 GR X1 GR

171 LiYY/EB ELECTRONIC / ELECTRONIC POWER bare copper Application: class 5 = fine stranded PVC PVC Colour outer sheath blue VDE /IEC Oil-resistant EN C temperature, in motion/ C during installation resistance 100 MOhmxkm Specific inductivity 0.7 mh/km Nominal voltage Uo 250 V For signal transmission between electronic devices, in computer systems, process control units or office equipment. Due to the blue outer sheath the cable is suitable for application in intrinsically safe circuits X0.75 BL X0.75 BL X0.75 BL X0.75 BL X1 BL X1 BL X1 BL X1 BL X1.5 BL X1.5 BL X1.5 BL COAXIAL LAN ELECTRONIC 171

172 POWER ELECTRONIC / ELECTRONIC LiYCY bare copper Application: class 5 = fine stranded PVC Screen copper braid, tinned Screen coverage 70 % PVC VDE /IEC Oil-resistant EN C temperature, in motion/ C during installation Nominal voltage Uo 250 V Nominal voltage U 250 V For signal transmission between electronic devices, in computer systems, process control units or office equipment with increased electromagnetic compatibility requirements. ELECTRONIC LAN COAXIAL X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.75 GR X0.75 GR X0.75 GR

173 LiYCY ELECTRONIC / ELECTRONIC X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.34 GR X2X0.34 GR X2X0.34 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X1 GR X2X1 GR X2X1 GR POWER LAN COAXIAL ELECTRONIC 173

174 POWER ELECTRONIC / ELECTRONIC LiYCY/EB ELECTRONIC LAN COAXIAL bare copper Application: class 5 = fine stranded PVC Screen copper braid Screen coverage 85 % PVC VDE /IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 10 x DA resistance 100 MOhmxkm For signal transmission between electronic devices, in computer systems, process control units or office equipment with increased electromagnetic compatibility requirements. Due to the blue outer sheath the cable is suitable for application in intrinsically safe circuits X0.5 BL X0.5 BL X0.5 BL X0.75 BL X0.75 BL X0.75 BL X0.75 BL X0.75 BL X0.75 BL X0.75 BL X0.75 BL X1 BL X1 BL X1 BL X1 BL X1 BL X1 BL X1 BL X1 BL X1.5 BL X1.5 BL X1.5 BL X1.5 BL X1.5 BL X1.5 BL X1.5 BL X1.5 BL

175 LiYCY/EB TP ELECTRONIC / ELECTRONIC POWER LiHCH bare copper Application: class 5 = fine stranded PVC Screen copper braid Screen coverage 85 % PVC VDE /IEC Maximum permitted conductor temperature 70 C C temperature, in motion/ C during installation Bending radius, fixed installation 10 x DA resistance 100 MOhmxkm For signal transmission between electronic devices, in computer systems, process control units or office equipment with increased electromagnetic compatibility requirements. Due to the blue outer sheath the cable is suitable for application in intrinsically safe circuits X2X0.75 BL X2X0.75 BL ELECTRONIC bare copper Application: class 5 = fine stranded Halogen-free data cable for marange signal transmission between FRNC-compound HI1 electronic devices, in computer Screen copper braid systems, process control units, office FRNC-compound HM1 equipment etc. VDE /IEC Halogen-free DIN EN 50267/IEC C Bending radius, fixed installation 7.5 x DA Bending radius, moving application 15 x DA Nominal voltage Uo 250 V Core identification colours acc. to DIN LAN COAXIAL /en/ X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.5 GR X0.75 GR

176 POWER ELECTRONIC ELECTRONIC / ELECTRONIC LiHCH X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X0.75 GR X1 GR X1 GR X1 GR X1 GR X1 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X1.5 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X1 GR X2X1 GR Li2YCYv LAN COAXIAL bare copper Application: class 2, 7-wired construction polyethylene Screen copper braid Screen coverage 75 % PVC, enforced Colour outer sheath black UV-resistant yes For outdoor use yes C temperature, in motion/ 0-60 C during installation Bending radius, fixed installation 15 x DA Low-capacitance cable for signal transmission in the ma-range under heavy environmental influences, outdoors and for direct burial. The cable is suitable for Maxi-Termi-Point contacting X2X0.22 SW X2X0.22 SW X2X0.34 SW X2X0.34 SW X2X0.34 SW X2X0.34 SW X2X0.5 SW X2X0.5 SW

177 Li2YCYv ELECTRONIC / ELECTRONIC X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X0.5 SW X2X1 SW X2X1 SW X2X1 SW POWER COAXIAL LAN ELECTRONIC 177

178 POWER ELECTRONIC BUS INSTALLATION Item number Item name Colour Cop. weight FABER EIB-bus cable 02X2X0,8 GN 21,0 6,3 55, FABER EIB-bus cable 04X2X0,8 GN 41,0 8,8 92, FABER EIB-bus cable halogen-free 02X2X0,8 GN 21,0 6,3 55, FABER EIB-bus cable direct burial 02X2 X0,8 SW 21,0 8,0 75,0 ELECTRONIC Intercounication bus cable LiY 02X1,5 sq + L-2Y 02X2X0,6 GN 57,0 8,5 90, Intercounication bus cable FRNC 02X1,5 sq + L-2Y 02X2X0,6 GR 57,0 8,5 90,0 UNSHIELDED INDUSTRY TYPES PROFILED FLAT Item number Item name Colour Cop. weight B x H ca FABER AS-Interface BUS Rubber 02X1,5 SW 29,0 4 x 10 57, FABER AS-Interface BUS Rubber 02X1,5 GE 29,0 4 x 10 57, FABER AS-Interface BUS TPE 02X1,5 SW 29,0 4 x 10 57, FABER AS-Interface BUS PUR 02X1,5 GE 29,0 4 x 10 57, FABER AS-Interface BUS PUR 02X2,5 GE 48,0 4 x 10 84, FABER EFK AS-Interface BUS PUR 02X1,5 GE 30,0 4 x 10 57,0 LAN FABER EFK AS-Interface BUS PUR 02X1,5 SW 30,0 4 x 10 57,0 PROFIBUS 150 OHM COAXIAL Item number Item name Colour Cop. weight Profibus PVC L2/FIP/DP/FMS 2Y(St)CY 01X2X0,64 VL 29,0 7,8 57, Profibus Fast Connect L2/FIP/DP/FMS 2YY(St)CY 01X2X0,64 VL 29,0 7,8 60, Profibus UL/CSA L2 FIP/DP/FMS 2Y(St)CY 01X2X0,64 VL 29,0 7,8 57, Profibus Fast Connect L2/FIP/DP/FMS 2YY(St)CY 01X2X0,64 BL 29,0 8,2 70, Profibus PVC L2/FIP/DP/FMS Fast Connect, cul 01X2X0,64/7 VL 29,0 7,9 73, Profibus PVC L2/FIP/DP/FMS Fast Connect, cul 01X2X0,64 VL 29,0 8,0 82, Profibus FRNC L2/FIP/DP/FMS 2Y(St)CH 01X2X0,64 GN 29,0 7,8 55, Profibus FRNC L2/FIP/DP/FMS 2Y(St)CH 01X2X0,64 VL 29,0 7,8 55, Profibus direct burial L2/FIP/DP/FMS 2Y(St)CY2Y 01X2X0,64 SW 29,0 10,0 87, Profibus EFK PUR L2/FIP/DP/FMS - 19 Strand 01X2X0,64 VL 29,0 8,1 64, Profibus EFK PUR FC L2/FIP/DP/FMS - 19 Strand 01X2X0,64 VL 29,0 8,0 83, Profibus Festoon PVC L2/FIP/DP/FMS - 19 Strand 01X2X0,64 PT 29,0 8,3 63,

179 ELECTRONIC POWER PROFIBUS FOR PROCESS AUTOMATION Item number Item name Colour Z Ohm Cop. weight Profibus PA UL/CSA FR 01X2XAWG 18/7 SW ,0 7,9 73, Profibus PA UL/CSA FR 01X2XAWG 18/7 BL ,0 7,9 73, FOUNDATION FIELDBUS 01X2XAWG 18/7 OR ,0 7,3 73,0 CAN-BUS 120 OHM ELECTRONIC Item number Item name Colour Cop. weight CAN-Bus-FIX PVC UL/CSA 01X2X0,22 VL 17,0 6,0 38, CAN-Bus-FIX PVC UL/CSA 02X2X0,22 VL 36,0 7,5 70, CAN-Bus-FIX PVC UL/CSA 01X2X0,34 VL 23,0 6,6 55, CAN-Bus-FIX PVC UL/CSA 02X2X0,34 VL 46,4 8,0 88, CAN-Bus-FIX PVC UL/CSA 01X2X0,5 VL 42,0 7,3 83, CAN-Bus-FIX PVC UL/CSA 02X2X0,5 VL 59,4 9,0 106,0 LAN CAN-Bus-FIX PVC UL/CSA 01X2X0,75 VL 53,0 8,9 108, CAN-Bus-FIX PVC UL/CSA 02X2X0,75 VL 81,0 12,4 141, CAN-Bus BURIAL YY CUL CMX UV-BEST. 02X2X0,75 SW 81,0 13,6 217, CAN-Bus-EFK PUR UL/CSA 02X2X0,25 VL 33,0 8,4 68,0 COAXIAL CAN-Bus-EFK PUR UL/CSA 02X2X0,34 VL 52,4 9,6 88, CAN-Bus-EFK PUR UL/CSA 01X2X0,5 VL 42,0 8,2 72, CAN-Bus-EFK PUR UL/CSA 02X2X0,5 VL 59,4 10,8 106, DeviceNet (TM) Bus FRNC 01X2X AWG X2X AWG 15 EFK UL VL 94,0 12,3 197, DeviceNet (TM) Bus FRNC 01X2X AWG X2X AWG 22 EFK UL VL 36,0 7,3 65,0 BUS SYSTEMS FOR BROADCAST, TELEVISION, STUDIO / STAGE Item number Item name Colour Cop. weight AES/EBU & DMX STDY 02X0,34 SW 10,2 6,6 50, AES/EBU & DMX STCY 04X0,34 SW 33,0 7,2 65,0 /en/ 179

180 POWER ELECTRONIC SERIAL DATA BUSES The use of sensors, actuators and processing electronics has been part and parcel of the standard toolbox in industrial measurement and control technologies for decades. ELECTRONIC In this regard, systems with distributed intelligence are competing with centrally organized systems. The data still need to be transported to and from the information sources, users or processors in any case. In the vast majority of cases, this is still done using copper data lines, even if wireless radio or IR solutions and/or optical fibre cables are increasingly also gaining ground. In combination with the corresponding send and receive blocks, these data lines form a so-called bus system. Although the data lines of most systems look quite similar inside (one or two twisted pairs of cores for serial data transmission), all the various system providers have still developed a series of more or less proprietary cables that are specifically tailored to the application areas of their bus system. Many bus systems can meanwhile have their components certified by the panel that defines the bus specification. This manifests the differences between the individual cables of various bus systems or also within a system, not so much in their electrical or transmission-related qualities as in their suitability for often very narrowly defined application cases, e.g. use in cable carriers, direct underground installation, or resistance to different environmental factors. In some systems, the bus line not only carries the actual data, but also the power supply for the individual components, sometimes even by the same pair of conductors. In addition to this, most cable types are also available in a conventional (usually PVC-sheathed) and a halogen-free version. Bus system Standard Network topology Data rate LAN EIB/KNX EN 50090, ISO/IEC linear AS-I (Actor-Sensor Interface) EN 50295, IEC any 167 kbit/s SINEG L2 Profibus FIP DP IEC linear 500 kbit/s COAXIAL INDUSTRIAL ETHERNET (Profinet) ISO/ IEC Profibus PA (Process automation) Chemical industry FOUNDATION FIELDBUS Chemical industry CAN (Controller Area Network) ISO linear/star 100 kbit/s DeviceNetTM ODVA linear/star 100 kbit/s LON (Local Operating Network) EN any 78,1 kbit/s DESINA VDW AES / EBU / DMX EIA kbit/s 180

181 DRAG CHAIN / ELECTRONIC FABER EFK Li9YC11Y (Drag chain cable) POWER bare copper Application: class 6 = extra finely stranded polypropylene Screen copper braid, tinned Screen coverage 85 % polyurethan Colour outer sheath grey RAL 7001 VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN C temperature, in motion/ C during installation Highly flexible and low-capacitance data cable for constant movement under extreme conditions with specific EMC (electromagnetic compatibility) requirements. The cable is halogen-free, flameretardant, hydrolysis- and microberesistant and largely oil-resistant. Please note our instructions for the use of drag chain cables on our website X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.14 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.25 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X0.34 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.14 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.25 GR X2X0.34 GR X2X0.34 GR X2X0.34 GR X2X0.34 GR X2X0.34 GR ELECTRONIC LAN COAXIAL

182 POWER ELECTRONIC / DRAG CHAIN FABER EFK Li9YC11Y (Drag chain cable) ELECTRONIC X2X0.34 GR X2X0.34 GR X2X0.34 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.5 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X0.75 GR X2X1 GR X2X1 GR X2X1 GR X2X1 GR X2X1 GR FABER EFK Single core 12Y11Y (Drag chain cable) LAN COAXIAL Specification/Standard UL/CSA Application: bare copper class 6 = extra finely stranded TPE polyurethan Colour outer sheath black VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Highly flexible control cable for constant moving applications under heavy duty conditions. The cable is halogen-free, flame-retardant and resistant to most chemicals used in industrial environment. Please pay attention to our installation instructions for drag chain cables on our website X6 SW X10 SW X16 SW X25 SW X35 SW X50 SW X70 SW X95 SW

183 FABER EFK Single core 12Y11Y (Drag chain cable) DRAG CHAIN / ELECTRONIC POWER X120 SW X150 SW X185 SW X240 SW G6 GG G10 GG G16 GG G25 GG G35 GG G50 GG G70 GG G95 GG G120 GG G150 GG G185 GG FABER EFK Single core 12YC11Y (Drag chain cable) Specification/Standard UL/CSA Application: bare copper class 6 = extra finely stranded TPE Screen copper braid, tinned Screen coverage 85 % polyurethan Colour outer sheath orange RAL 2003 (DESINA) VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN C Highly flexible data cable for constant movement under extreme conditions with specific EMC (electromagnetic compatibility) requirements. It is applicable in standard drag chains without tensile load. The cable is flame-retardant, and largely resistant to many chemicals used in industrial environment. Please pay attention to our instructions for the use of drag chain cables on our website X6 OR X10 OR X16 OR X25 OR X35 OR X50 OR X70 OR X95 OR X120 OR X150 OR X185 OR X240 OR LAN COAXIAL ELECTRONIC 183

184 POWER ELECTRONIC / DRAG CHAIN FABER EFK 300 P (Drag chain cable) bare copper Application: class 6 = extra finely stranded TPE/PP polyurethan Colour outer sheath grey RAL 7001 VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN C temperature, in motion/ C during installation Bending radius, fixed installation 4 x DA Bending cycles, max. 5 Mio. Highly flexible control cable for constant moving applications under heavy duty conditions. The cable is halogen-free, flame-retardant and resistant to most chemicals used in industrial environment. Please pay attention to our installation instructions for drag chain cables on our website. ELECTRONIC LAN COAXIAL X0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR X0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR X1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR X1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR X2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G4 GR G6 GR G10 GR

185 FABER EFK 300 P (Drag chain cable) DRAG CHAIN / ELECTRONIC POWER G16 GR G4 GR G6 GR G10 GR G16 GR G4 GR G6 GR G10 GR G16 GR FABER EFK 300 CP (Drag chain cable) bare copper Application: class 6 = extra finely stranded TPE/PP Material inner sheath polyurethan Screen copper braid, tinned Screen coverage 85 % polyurethan Colour outer sheath grey RAL 7001 VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN C Highly flexible control cable for the constantly moving equipment under extreme conditions for indoor and outdoor use combined with specific EMC (electromagnetic compatibility) requirements. The cable is halogenfree, flame-retardant and resistant to most chemicals occurirng in industry environment. Please pay attention to our instructions for the use of drag chain cables on our website. ELECTRONIC X0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR X0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR X1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR X1.5 GR G1.5 GR G1.5 GR LAN COAXIAL

186 POWER ELECTRONIC / DRAG CHAIN FABER EFK 300 CP (Drag chain cable) ELECTRONIC G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR X2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G4 GR G6 GR G10 GR G16 GR G4 GR G6 GR G10 GR G16 GR G4 GR G6 GR G10 GR G16 GR FABER EFK 310 Y (Drag chain cable) LAN COAXIAL Specification/Standard UL/CSA Application: bare copper class 6 = extra finely stranded PVC PVC Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN C temperature, in motion/ C during installation Bending radius, fixed installation 5 x DA Bending cycles, max. 3 Mio. Highly flexible control cable for application in permanently moving machine parts or in power chains (indoor). For use in free movement without tensile stress application and in drag chains. The cable is flame-retardant and resistant to most chemicals occurring in industry environment. Please pay attention to our instructions for the use of drag chain cables on our website X0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR X0.75 GR

187 FABER EFK 310 Y (Drag chain cable) DRAG CHAIN / ELECTRONIC POWER G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR X1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR X1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR X2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G4 GR G4 GR G4 GR G6 GR G6 GR G6 GR LAN COAXIAL ELECTRONIC 187

188 POWER ELECTRONIC / DRAG CHAIN FABER EFK 310 CY (Drag chain cable) ELECTRONIC LAN COAXIAL Specification/Standard UL/CSA Application: bare copper class 6 = extra finely stranded PVC Material inner sheath PVC Screen copper braid, tinned Screen coverage 85 % PVC Colour outer sheath grey RAL 7001 VDE /IEC Oil-resistant EN C Highly flexible data cable for use in moving applications under extreme conditions with specific EMC (electromagnetic compatibility) requirements. It is applicable in standard drag chains without tensile load. The cable is flameretardant, and largely resistant to most chemicals used in industrial environment. Please pay attention to our instructions for the use of drag chain cables on our website X0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR G0.5 GR X0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR G0.75 GR X1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR G1 GR X1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR G1.5 GR X2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G2.5 GR G4 GR

189 FABER EFK 310 CY (Drag chain cable) DRAG CHAIN / ELECTRONIC POWER G4 GR G4 GR G6 GR G6 GR G6 GR FABER EFK Feedback-CP Indramat (Drag chain cable) Standard Indramat Standard INK Application: Specification/Standard UL/CSA bare copper class 6 = extra finely stranded TPE Screen copper braid, tinned Screen coverage 85 % polyurethan Colour outer sheath orange RAL 2003 VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN Connection cable between encoder/ resolver and servo controller. For application in machine tools and drag chains with medium mechanical stress. Please pay attention to our instructions for the use of drag chain cables on our website [04X2X X0.5] cul - OR INK [04X2X X1] cul - OR INK [09X0.5] cul - INK-0208 OR [04X1 + 4X2X (4X0.14)] OR cul - INK [03X X(2X0.25)D + OR X1] cul - INK [02X2X X0.5] cul - INK-0750 OR LAN COAXIAL ELECTRONIC 189

190 POWER ELECTRONIC / DRAG CHAIN FABER EFK Feedback-CP Siemens (Drag chain cable) ELECTRONIC LAN Standard Siemens Standard 6FX8008+ Application: Specification/Standard UL/CSA bare copper class 6 = extra finely stranded polypropylene Screen copper braid, tinned Screen coverage 85 % polyurethan Colour outer sheath green RAL 6018 (DESINA) VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN [08X2X0.18] cul - 6FX8008-1BD [04X2X X0.5] cul - 6FX8008-1BD [03X(2X0.14) + 2X(0.5)] cul - 6FX8008-1BD [03X(2X0.14) + 4X X0.5] cul - 6FX8008-1BD [03X(2X0.14) + 4X X X0.25] cul - 6FX8008-1BD [02X2X0.18] cul - 6FX8008-1BD [04X2X0.18] cul - 6FX8008-1BD [12X0.25] cul - 6FX8008-1BD81 COAXIAL Connection cable between encoder/ resolver and servo controller. For application in machine tools and drag chains with medium mechanical stress. Please pay attention to our instructions for the use of drag chain cables on our website. GN GN GN GN GN GN GN GN

191 DRAG CHAIN / ELECTRONIC FABER EFK Servo-CP Indramat (Drag chain cable) POWER Standard Indramat Standard INK Application: Specification/Standard UL/CSA bare copper class 6 = extra finely stranded TPE Screen coverage 85 % polyurethan Colour outer sheath orange RAL 2003 (DESINA) VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN C [04G (2X0.5)StD] cul - INK [04G1 + 2x(2x0.75)StC] cul - INK [04G x(2x0.75)StC] cul - INK [04G x(2x1)StC] cul - INK [04G4 + (2x1.5)StC + (2x1.0) StC] cul - INK [04G6 + (2x1.5)StC + (2x1.0) StC] cul - INK [04G10 + (2x1.5)StC + (2x1.0) StC] cul - INK [04G16 + 2x(2x1.5)StC] cul - INK [04G25 + 2x(2x1.5)StC] cul - INK [04G35 + 2x(2x1.5)StC] cul - INK-0667 Connection cable between servo controller and frequency driven motor. For application in machine tools and drag chains with medium mechanical stress. Please pay attention to our instructions for the use of drag chain cables on our website. OR OR OR OR OR OR OR OR OR OR LAN COAXIAL ELECTRONIC 191

192 POWER ELECTRONIC / DRAG CHAIN FABER EFK Servo-CP Siemens (Drag chain cable) LAN COAXIAL ELECTRONIC Standard Siemens Standard 6FX8008+ Application: Specification/Standard UL/CSA bare copper class 6 = extra finely stranded polypropylene Screen copper braid, tinned Screen coverage 85 % polyurethan Colour outer sheath orange RAL 2003 (DESINA) VDE /IEC Halogen-free DIN EN 50267/IEC Oil-resistant EN Low-capacitance connection cable between servo controller and frequency driven motor. For application in machine tools and drag chains with medium mechanical stress. Please pay attention to our instructions for the use of drag chain cables on our website [04G1.5] cul - OR FX8008-1BB [04G2.5] cul - OR FX8008-1BB [04G4] cul - 6FX8008-1BB31 OR [04G6] cul - 6FX8008-1BB41 OR [04G10] cul - OR FX8008-1BB [04G16] cul - OR FX8008-1BB [04G25] cul - OR FX8008-1BB [04G35] cul - OR FX8008-1BB [04G50] cul - OR FX8008-1BB [04G70] cul - OR FX8008-1BB [04G1.5 + (2X1.5)] cul - OR FX8008-1BA [04G2.5 + (2X1.5)] cul - OR FX8008-1BA [04G4 + (2X1.5)] cul - OR FX8008-1BA [04G6 + (2X1.5)] cul - OR FX8008-1BA [04G10 + (2X1.5)] cul - OR FX8008-1BA [04G16 + (2X1.5)] cul - OR FX8008-1BA [04G25 + (2X1.5)] cul - OR FX8008-1BA [04G35 + (2X1.5)] cul - OR FX8008-1BA [04G50 + (2X1.5)] cul - 6FX8008-1BA50 OR

193 Li2YCY PiMF SPECIAL / ELECTRONIC POWER bare copper Application: class 5 = fine stranded polyethylene Stranding unit pair Stranding pairs in layers Screen over stranding unit foil Screen over strand Cu-braid, tinned Screen coverage 80 % PVC Colour outer sheath grey VDE /IEC For outdoor use yes Data cable with low operating capacity, pair shielding and overall shielding. Suitable for connecting process measurement and control components in environments with high interference levels. The combination of film pair shielding and mesh overall shielding ensures optimal protection from high- and low-frequency interference. For permanent installation in dry and humid rooms X2X0.5 GR X2X0.5 GR X2X0.75 GR X2X0.75 GR X2X1 GR X2X1 GR COAXIAL LAN ELECTRONIC 193

194 NOTES COAXIAL LAN ELECTRONIC POWER 194

195 POWER ELECTRONIC POWER WITH 196 (N)HXH-O E (N)HXH-J E (N)HXCH E (N)HXH-O Plus 200 (N)HXH-J Plus 201 (N)HXCH Plus 202 (N)HXH-O E (N)HXH-J E (N)HXCH E LAN COAXIAL COMMUNICATION WITH 207 JE-H(St)H FE180/E JE-H(St)H FE180/E30-E JE-H(St)H FE180/E30 Fire signalisation cable 208 JE-H(St)H FE180/E30-E90 Fire signalisation cable 209 JE-H(St)HRH FE180/E30-E90 Fire signalisation cable 209

196 POWER WITH E30 OR E90 / POWER WITH (N)HXH-O E30 ELECTRONIC LAN COAXIAL Standard VDE 0266 Application: bare copper class 1, from 25 sq class 2 FRNC-compound HI1 FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30 Maximum permitted conductor temperature 90 C For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogenfree, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 C is approximately four times higher than at 20 C and the current carrying capacity is reduced respectively X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR X35 RM OR X50 RM OR X70 RM OR X95 RM OR X120 RM OR X150 RM OR X185 RM OR X240 RM OR X300 RM OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR /en/

197 POWER WITH / WITH E30 OR E90 (N)HXH-J E30 POWER Standard VDE 0266 Application: bare copper class 1, from 25 sq class 2 FRNC-compound HI1 FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30 Maximum permitted conductor temperature 90 C For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogenfree, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 C is approximately four times higher than at 20 C and the current carrying capacity is reduced respectively. ELECTRONIC X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR X35 RM OR X50 RM OR X70 RM OR X25/16 RM OR X35/16 RM OR X50/25 RM OR X70/35 RM OR X95/50 RM OR X120/70 RM OR X150/70 RM OR X185/95 RM OR X240/120 RM OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR X35 RM OR X50 RM OR X70 RM OR X95 RM OR LAN COAXIAL

198 POWER WITH E30 OR E90 / POWER WITH (N)HXH-J E30 ELECTRONIC X120 RM OR X150 RM OR X185 RM OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR X35 RM OR X1.5 RE OR X1.5 RE OR X1.5 RE OR X1.5 RE OR X1.5 RE OR X1.5 RE OR X2.5 RE OR X2.5 RE OR X2.5 RE OR X2.5 RE OR X2.5 RE OR X2.5 RE OR COAXIAL LAN 198

199 POWER WITH / WITH E30 OR E90 (N)HXCH E30 POWER Standard VDE 0266 Application: bare copper class 1, from 25 sq class 2 FRNC-compound HI1 Concentric conductor Cu FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30 For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogenfree, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min.= IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 C is approximately four times higher than at 20 C and the current carrying capacity is reduced respectively. ELECTRONIC X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X16/16 RE OR X25/16 RM OR X50/25 RM OR X70/35 RM OR X95/50 RM OR X120/70 RM OR X150/70 RM OR X185/95 RM OR X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X16/16 RE OR X25/16 RM OR X35/16 RM OR X50/25 RM OR X70/35 RM OR X95/50 RM OR X120/70 RM OR X150/70 RM OR LAN COAXIAL

200 POWER WITH E30 OR E90 / POWER WITH (N)HXCH E X185/95 RM OR X240/120 RM OR X1.5/2.5 RE OR X2.5/2.5 RE OR X1.5/2.5 RE OR X2.5/4 RE OR X1.5/2.5 RE OR X1.5/2.5 RE OR ELECTRONIC LAN COAXIAL (N)HXH-O Plus Standard VDE 0266 Application: bare copper class 1 = solid FRNC-compound HI1 FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30 Maximum permitted conductor temperature 90 C For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR

201 POWER WITH / WITH E30 OR E90 (N)HXH-J Plus POWER Standard VDE 0266 Application: bare copper class 1 = solid FRNC-compound HI1 FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30 Maximum permitted conductor temperature 90 C For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X1.5 RE OR X2.5 RE OR X6 RE OR X10 RE OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X1.5 RE OR X2.5 RE OR ELECTRONIC LAN COAXIAL 201

202 POWER WITH E30 OR E90 / POWER WITH (N)HXCH Plus ELECTRONIC LAN COAXIAL Standard VDE 0266 Application: bare copper class 1 = solid FRNC-compound HI1 Concentric conductor Cu FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30 Cable with concentric conductor for installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X1.5/2.5 RE OR X2.5/2.5 RE OR

203 POWER WITH / WITH E30 OR E90 (N)HXH-O E90 POWER Standard VDE 0266 Application: bare copper class 1, from 25 sq class 2 FRNC-compound HI1 FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E90 Maximum permitted conductor temperature 90 C For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogenfree, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331), EN and EN Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling). A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 C is approximately 4,5 times higher than at 20 C and the current carrying capacity has to be reduced respectively X16 RE OR X25 RM OR X35 RM OR X50 RM OR X70 RM OR X95 RM OR X120 RM OR X150 RM OR X185 RM OR X240 RM OR X300 RM OR X400 RM OR X1.5 RE OR X95 RM OR X120 RM OR ELECTRONIC LAN COAXIAL /en/ 203

204 POWER WITH E30 OR E90 / POWER WITH (N)HXH-J E90 ELECTRONIC LAN COAXIAL Standard VDE 0266 Application: bare copper class 1, from 25 sq class 2 FRNC-compound HI1 FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E90 Maximum permitted conductor temperature 90 C For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogenfree, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331), EN and EN Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling). A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 C is approximately 4,5 times higher than at 20 C and the current carrying capacity has to be reduced respectively X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR X35 RM OR X50 RM OR X70 RM OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR X35 RM OR X50 RM OR X70 RM OR X95 RM OR X120 RM OR X150 RM OR X185 RM OR X240 RM OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR X10 RE OR X16 RE OR X25 RM OR

205 (N)HXH-J E90 POWER WITH / WITH E30 OR E90 POWER (N)HXCH E X35 RM OR X70 RM OR X95 RM OR X120 RM OR X150 RM OR X185 RM OR X1.5 RE OR X1.5 RE OR X1.5 RE OR X2.5 RE OR X1.5 RE OR X2.5 RE OR X4 RE OR X6 RE OR Standard VDE 0266 Application: bare copper class 1, from 25 sq class 2 FRNC-compound HI1 Concentric conductor Cu FRNC-compound HM1 Colour outer sheath orange VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E90 For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogenfree, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 331). Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 C is approximately 4,5 times higher than at 20 C and the current carrying capacity has to be reduced respectively. ELECTRONIC LAN COAXIAL X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X16/16 RE OR X25/16 RM OR X35/16 RM OR

206 POWER WITH E30 OR E90 / POWER WITH (N)HXCH E90 ELECTRONIC COAXIAL LAN X50/25 RM OR X70/35 RM OR X95/50 RM OR X120/70 RM OR X150/70 RM OR X185/95 RM OR X240/120 RM OR X1.5/1.5 RE OR X2.5/2.5 RE OR X4/4 RE OR X6/6 RE OR X10/10 RE OR X16/16 RE OR X25/16 RM OR X35/16 RM OR X50/25 RM OR X70/35 RM OR X95/50 RM OR X120/70 RM OR X150/70 RM OR X185/95 RM OR X240/120 RM OR X2.5/2.5 RE OR X4/4 RE OR X1.5/2.5 RE OR X2.5/2.5 RE OR X1.5/2.5 RE OR X1.5/2.5 RE OR X2.5/4 RE OR X4/6 RE OR X1.5/6 RE OR X2.5/10 RE OR X1.5/6 RE OR X2.5/10 RE OR

207 COMMUNICATION WITH / WITH E30 OR E90 JE-H(St)H FE180/E30 POWER Standard VDE 0815 Application: tinned copper class 1 = solid FRNC-compound HI1 FRNC-compound HM2 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E C Bending radius, fixed installation 7.5 x DA For signal transmission within systems for measuring-, control-, data- and regulation technology and for use as an installation cable in fire hazard rooms with a high concentration of people or material assets and for installation of fire survival cable systems according to DIN 4102 part 12. For fixed installation in dry and wet rooms X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR JE-H(St)H FE180/E30-E90 LAN ELECTRONIC Standard VDE 0815 Application: bare copper FRNC-compound HI1 FRNC-compound HM2 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30-E C Bending radius, fixed installation 7.5 x DA Core identification colours + rings For signal transmission within systems for measuring-, control-, data- and regulation technology and for use as an installation cablefire hazard rooms with a high concentration of people and material assets and for installation of fire survival cable systems according to DIN 4102 part 12. For fixed installation in dry and wet rooms X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR COAXIAL 207

208 POWER WITH E30 OR E90 / COMMUNICATION C ABLES WITH JE-H(St)H FE180/E30-E X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR X2X0.8 OR JE-H(St)H FE180/E30 Fire signalisation cable ELECTRONIC LAN COAXIAL bare copper Application: FRNC-compound HI1 FRNC-compound HM2 VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E C Bending radius, fixed installation 7.5 x DA Nominal voltage U 225 V Core identification colours + rings For signal transmission between electronic devices, in computer systems of process control units in fire hazard rooms with a high concentration of people or material assets and for installation of circuits with circuit integrity E30/ E90 according to DIN 4102 part 12, with tested cable systems. For fixed installation in dry and damp areas on certified carrier systems. By the special sheath printing -Brandmeldekabel- this cable is particularly designed for the use in fire signalisation systems X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT

209 COMMUNICATION WITH / WITH E30 OR E90 JE-H(St)H FE180/E30-E90 Fire signalisation cable POWER Standard VDE 0815 Application: bare copper FRNC-compound HI1 FRNC-compound HM2 Colour outer sheath red VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30-E C Bending radius, fixed installation 7.5 x DA For signal transmission between electronic devices, in computer systems of process control units in fire hazard rooms with a high concentration of people or material assets and for installation of circuits with circuit integrity E30/ E90 according to DIN 4102 part 12, with tested cable systems. For fixed installation in dry and damp areas on certified carrier systems. By the special sheath printing -Brandmeldekabel- this cable is particularly designed for the use in fire signalisation systems X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT X2X0.8 RT ELECTRONIC JE-H(St)HRH FE180/E30-E90 Fire signalisation cable LAN Standard VDE 0815 Application: tinned copper class 1 = solid FRNC-compound HI1 Armour round or flat steel wires, galvanized FRNC-compound HM2 Colour outer sheath red VDE /IEC (Kat. C) Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC Fire-resistant FE 180 Circuit integrity E30-E90 For signal transmission within systems for measuring-, control-, data- and regulation technology and as installation cable fire hazard rooms with a high concentration of people or material assets and for installation of fire survival cable systems according to DIN 4102 part 12. For fixed installation in dry and wet rooms X2X0.8 RT X2X0.8 RT COAXIAL

210 NOTES COAXIAL LAN ELECTRONIC POWER 210

211 POWER LAN LAN COAXIAL ELECTRONIC 100-MHZ 212 FABER dataline MHZ 213 FABER dataline MHZ 214 FABER dataline FABER dataline 1000 duplex 214 FABER dataline 1000 outdoor 215

212 POWER LAN / 100-MHZ FABER dataline 100 Standard Stranding Screen ISO/IEC 11801, EN 50173, EN 55022, E DIN bare copper polyolefin pairs in layers plastic coated aluminium foil + solid copper drain wire polyolefin Bending radius, fixed installation 4 x DA Bending radius, moving application 8 x DA Impedance 100 Ohm resistance MOhmxkm Velocity factor (NVP) 0.66 v/c Category 5 Application: For the connection of IT system units in the desktop area (tertiary sector), e.g. between floor distributors and workstation up to 100 Mbit/s (Category 5). It fully complies with the electromagnetic compatibility requirements (EMC) of European Standard EN and the guidelines of the European Postal Administration. ELECTRONIC X2XAWG26 GR X2XAWG24 OR COAXIAL LAN 212

213 FABER dataline MHZ / LAN POWER ISO/IEC 11801, EN 50173, EN Specification/Standard 55022, complies with EN und EN bare copper class 1 = solid cross-linked polyolefincopolymer Stranding pairs in layers Screen aluminium foil + copper braid, tinned polyolefin-compound HM4, FRNC Colour outer sheath orange RAL 2004 VDE /IEC Halogen-free DIN EN 50267/IEC C Bending radius, fixed installation 8 x DA Item number Item name Colour Cop. weight Application: For the connection of IT system units in the desktop area (tertiary sector), e.g. between floor distributors and workstation up to 100 Mbit/s (Category 5). It fully complies with the electromagnetic compatibility requirements (EMC) of European Standard EN and the guidelines of the European Postal Administration. Furthermore, the copper braiding ensures perfect matching with screened connectors. W x H X2XAWG24 (simplex) OR X2XAWG24 (duplex) OR x ELECTRONIC COAXIAL LAN 213

214 POWER LAN / 1000-MHZ FABER dataline 1000 CPR-performance acc. to EN on request ISO/IEC 11801, EN 50173, Specification/Standard EN 55022, EN , EN 50167, EN bare copper foam-pe Screen over stranding unit foil Screen over strand Cu-braid, tinned FRNC-compound HM2 Colour outer sheath orange RAL 2004 VDE /IEC Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C Application: For the connection of IT system units in the desktop area (tertiary sector), e.g. between floor distributors and workstation up to 1000 Mbit/s (category 7+). It fully complies with the electromagnetic compatibility requirements (EMC) of European Standard EN and the guidelines of the European Postal Administration. Furthermore, the copper braiding ensures perfect matching with screened connectors. ELECTRONIC X2XAWG23 OR X2XAWG23 (reel-in-box) OR X2XAWG23 (coil 100) OR FABER dataline 1000 duplex LAN COAXIAL CPR-performance acc. to EN on request ISO/IEC 11801, EN 50173, Specification/Standard EN 55022, EN , EN 50167, EN bare copper foam-pe Screen over stranding unit foil Screen over strand Cu-braid, tinned FRNC-compound HM2 Colour outer sheath orange RAL 2004 VDE /IEC Smoke density DIN EN 61034/IEC Halogen-free DIN EN 50267/IEC C Application: For the connection of IT system units in the desktop area (tertiary sector), e.g. between floor distributors and workstation up to 1000 Mbit/s (category 7+). It fully complies with the electromagnetic compatibility requirements (EMC) of European Standard EN and the guidelines of the European Postal Administration. Furthermore, the copper braiding ensures perfect matching with screened connectors. W x H X2XAWG23 OR x X2XAWG23 (reel-in-box) OR x /en/

215 FABER dataline 1000 outdoor 1000-MHZ / LAN POWER Specification/Standard Screen over stranding unit Screen over strand Colour outer sheath UV-resistant temperature, in motion/ during installation Bending radius, fixed installation Bending radius, moving application EN 50173, EN , ISO/ IEC 11801, IEC bare copper foam-pe foil Cu-braid, tinned polyethylene black yes C C 4 x DA 8 x DA Application: For the connection of IT system units in the desktop area (tertiary sector), e.g. between floor distributors and workstation up to 1000 Mbit/s (category 7+). It fully complies with the electromagnetic compatibility requirements (EMC) of European Standard EN and the guidelines of the European Postal Administration. Furthermore, the copper braiding ensures perfect matching with screened connectors X2XAWG23 SW ELECTRONIC COAXIAL LAN 215

216 NOTES COAXIAL ELECTRONIC LAN POWER 216

217 POWER COAXIAL COAXIAL LAN ELECTRONIC RG-TYPES 218 SAT / CATV 219

218 POWER COAXIAL LAN COAXIAL ELECTRONIC COAXIAL CABLE / RG-TYPES Use: For data and signal transmission across a broad range of frequencies and distances, for connecting antennae, measuring equipment, transmission or reception systems, and other high-frequency appliances. Item number Item name Z Ohm Cop. weight RG 11 A/U 75 56,0 10,2 144, RG 58 C/U 50 20,0 5,0 38, RG 58 C/U FRNC 50 20,0 5,0 38, RG 59 B/U 75 24,0 6,1 57, RG 59 B/U FRNC 75 24,0 6,1 57, RG 62 A/U 93 25,0 6,2 52, RG 174 A/U 50 6,0 2,8 11, RG 179 B/U 75 7,5 2,5 16, RG ,0 10,3 155, RG 214 /U ,0 10,8 205,

219 COAXIAL CABLE / SAT / CATV COAXIAL POWER Use: For connecting satellite reception systems and antennae, video and broadband TV systems, but also for terrestrial radio and television reception antennae. Item number Item name Colour Z Ohm Cop. weight FABER SAT 1,1/5,0 DIGITAL 3 GHz WS 75 25,0 6,8 55, FABER SAT 1,1/5,0 halogen-free DIGITAL 3 GHz WS 75 25,0 6,8 55, FABER HD-SAT 1,0/4,6 DIGITAL 3-S > 115 db WS 75 17,0 7,0 46, FABER HD-SAT 1,0/4,6 DIGITAL 3-S > 115 db halogen-free HD-SAT+BK PE direct burial 1,6/7,3 DIGITAL 3-S >100 db SW 75 17,0 7,0 46,0 SW 75 39,0 10,3 107,0 ELECTRONIC FABER VIDEO 0,6/3,7 GN 75 24,0 6,2 45, FABER VIDEO flexible 0,6L/3,7 GN 75 24,0 6,2 45, FABER VIDEO halogen-free 0,6/3,7 GN 75 24,0 6,2 45,0 LAN FABER VIDEO Outdoor cable 1,0/6,6 SW 75 39,0 9,1 108, Video SDI/HD 0,8/3,7 + 02X0,75 SW 75 35,0 6,1 x 12,6 108,0 COAXIAL A-2YK2Y1 ikx 1,1/7,3 SW 75 69,0 11,0 142, A-2YOK2Y1 nkx 2,2/8,8 SW ,0 12,5 183, A-2YOK2Y1 qkx 3,3/13,5 SW ,0 17,0 347, A-2YOK2Y1 skx 4,9/19,4 SW ,0 24,4 500,

220 NOTES LAN ELECTRONIC COAXIAL POWER 220

221 POWER LAN COAXIAL ELECTRONIC - OUTDOOR 222 A-DQ(ZN)B2Y 2.2 kn (Central core) 222 A-DQ(ZN)B2Y Plus 3.0 kn (Central core) 223 A-DQ(ZN)B2Y 1.2 kn (Central core) 223 A-DQ(ZN)B2Y (Stranded cores) INDOOR 225 I-D(ZN)H 225 I-V(ZN)H 226 MULTI-PURPOSE CABLE 227 U-DQ(ZN)BH 227

222 POWER / - OUTDOOR A-DQ(ZN)B2Y 2.2 kn (Central core) ELECTRONIC LAN COAXIAL Standard ISO/IEC 794, DIN VDE 0888 Application: Fibre quality Type of tube Armour Colour outer sheath UV-resistant For outdoor use Cable metal-free temperature, in motion/ during installation see data sheet for fibres on our website gel-filled loose tube glass yarns polyethylene black no yes yes yes C 0-50 C Fibre optic cable with central tubes and non-metallic armour, strain relief and rodent protection. Swelling elements within the strand ensure longitudinally watertightness of the cable. The rugged and abrasionresistant PE-sheath enables easy installation in tubes and ducts. The sheath is halogen-free, but not flameretardant. Item number Item name Colour X4G50/ kn standard SW X6G50/ kn standard SW X8G50/ kn standard SW X12G50/ kn SW standard X16G50/ kn SW standard X24G50/ kn SW standard X4G62.5/ kn SW standard X6G62.5/ kn SW standard X8G62.5/ kn SW standard X12G62.5/ kn SW standard X16G62.5/ kn SW standard X24G62.5/ kn SW standard X4G50/ kn SW high grade (OM3) X6G50/ kn SW high grade (OM3) X8G50/ kn SW high grade (OM3) X12G50/ kn SW high grade (OM3) X16G50/ kn SW high grade (OM3) X24G50/ kn SW high grade (OM3) X12G50/ kn (OM4) SW

223 - OUTDOOR / A-DQ(ZN)B2Y Plus 3.0 kn (Central core) POWER Fibre quality Type of tube Armour Colour outer sheath temperature, in motion/ during installation see data sheet for fibres on our website gel-filled loose tube glass yarns polyethylene black no C C Application: Fibre optic cable with central tubes with non-metallic armour and rodent protection. Swelling elements within the strand ensure longitudinally watertightness of the cable. The rugged and abrasion-resistant PEsheath enables easy installation in tubes and ducts. The sheath is halogen-free, but not flame-retardant. Item number Item name Colour X24G50/ kn (OM4) SW X12G50/ kn SW standard X4E9/ kn SW X8E9/ kn SW X12E9/ kn SW X24E9/ kn SW ELECTRONIC A-DQ(ZN)B2Y 1.2 kn (Central core) Standard ISO/IEC 794, DIN VDE 0888 Application: Fibre quality Type of tube For outdoor use Cable metal-free temperature, in motion/ during installation see data sheet for fibres on our website gel-filled loose tube polyethylene no yes yes C C Fibre optic cable with central tubes and non-metallic armour, strain relief and rodent protection. Swelling elements within the strand ensure longitudinally watertightness of the cable. The rugged and abrasionresistant PE-sheath enables easy installation in tubes and ducts. The sheath is halogen-free, but not flameretardant. Item number Item name Colour X12E9/ kn SW X12G50/ kn SW standard LAN COAXIAL 223

224 POWER / - OUTDOOR A-DQ(ZN)B2Y (Stranded cores) ELECTRONIC Standard ISO/IEC 794, DIN VDE 0888 Application: Fibre quality Type of tube Armour Colour outer sheath UV-resistant For outdoor use Cable metal-free temperature, in motion/ during installation see data sheet for fibres on our website gel-filled loose tube glass yarns polyethylene black no yes yes yes C C Fibre optic cable with central tubes and non-metallic armour, strain relief and rodent protection. Swelling elements within the strand ensure longitudinally watertightness of the cable. The rugged and abrasionresistant PE-sheath enables easy installation in tubes and ducts. The sheath is halogen-free, but not flameretardant. Item number Item name Colour X12G50/125 standard SW X12G50/125 standard SW X12G62.5/125 standard SW X12G50/125 high grade SW X12G62.5/125 standard SW X12G50/125 high grade SW X12E9/125 SW X12E9/125 SW X12E9/125 SW X12E9/125 SW COAXIAL LAN 224

225 I-D(ZN)H - INDOOR / POWER Standard ISO/IEC 794, DIN VDE 0888 Application: Fibre quality see data sheet for fibres on our website Type of tube gel-filled loose tube FRNC-compound HM1 VDE /IEC Halogen-free DIN EN 50267/IEC Cable metal-free yes C temperature, in motion/ C during installation Optical indoor cable with central multifibre loose buffer and halogenfree outer sheath. For installation inside buildings on cable trays and in cable ducts. The cable must be terminated with a cable termination or in a cable splitter, direct mounting of fibre-connectors is not possible. Item number Item name Colour X4G50/125 standard OR X4G50/125 OR high grade (OM3) X4G62.5/125 standard OR X8G50/125 standard OR X8G50/125 OR high grade (OM3) X8G62.5/125 standard OR X12G50/125 standard OR X12G50/125 OR high grade (OM3) X12G62.5//125 standard OR X24G50/125 standard OR X24G50/125 high grade (OM3) OR ELECTRONIC COAXIAL LAN 225

226 POWER / - INDOOR I-V(ZN)H ELECTRONIC Standard ISO/IEC 794, DIN VDE 0888 Application: Fibre quality Type of tube Cable metal-free temperature, in motion/ during installation see data sheet for fibres on our website tight buffer FRNC-compound HM1 VDE /IEC yes C C Item number Item name Colour Indoor distribution cable with tight buffers and LSOH jacket. For installation in cable trays and ducts. The cable contains up to 24 fibres, which may be fitted directly to connectors and are suitable for fieldassembly. W x H X1G50/125 standard OR 10.0 x X1G62.5/125 standard OR 10.0 x X4G50/125 standard OR 5.1 x X4G62.5/125 standard OR 5.1 x 32.0 COAXIAL LAN 226

227 U-DQ(ZN)BH MULTI-PURPOSE CABLE / POWER CPR-performance acc. to EN on request Standard ISO/IEC 794, DIN VDE 0888 Fibre quality on request Type of tube gel-filled loose tube polyolefin VDE /IEC Halogen-free DIN EN 50267/IEC For outdoor use yes Cable metal-free yes C temperature, in motion/ C during installation Application: Installation-friendly universal optical fibre cable in a multifibre loose buffer design. The special jacket material allows installation outdoors, directly in the ground and use indoors where halogen-free, non-flaable and smoke-free cables are required. This makes it ideal for connections between buildings. Item number Item name Colour X12G50/ kn standard X12G50/ kn high grade (OM3) X24G50/ kn standard X24G50/ kn high grade (OM3) X12G62.5/ kn standard SW SW SW SW SW ELECTRONIC COAXIAL LAN 227

228 NOTES COAXIAL LAN ELECTRONIC POWER 228

229 POWER ELECTRONIC COPPER CONDUCTORS 230 Copper conductor, soft annealed, tinned 230 Copper conductor, soft annealed, bare, compacted 230 ESUY 231 COMPENSATION 232 COAXIAL LAN

230 POWER / COPPER CONDUCTORS Copper conductor, soft annealed, tinned Standard DIN 48201/1 and DIN VDE 0295 Application: copper, bare or tinned Annealed cables are used for earthing purposes in electrical installations. class 2 = stranded They have a mathematical tensile strength of 200 N/sq. Hard-drawn conductors are used primarily as overhead lines. Their mathematical tensile strength is 400 N/sq. ELECTRONIC X10 (7X1.35 ) VZ X16 (7X1.7 ) VZ X25 (7X2.1 ) VZ X35 (7X2.5 ) VZ X50 (19X1.8 ) VZ X70 (19X2.1 ) VZ X95 (19X2.5 ) VZ X120 (37X1.99 ) VZ X120 (19X2.8 ) VZ X150 RMv (37X2.32 ) VZ X240 RMv (61X2.32 ) VZ LAN Copper conductor, soft annealed, bare, compacted Standard DIN 48201/1 and DIN VDE 0295 Application: copper, bare or tinned Annealed cables are used for earthing purposes in electrical installations. class 2 = stranded They have a mathematical tensile strength of 200 N/sq. Hard-drawn conductors are used primarily as overhead lines. Their mathematical tensile strength is 400 N/sq. CONDUCTOR ROPES COAXIAL X35 RMv (7X2.6 ) BK X50 RMv (19X1.86 ) BK X70 RMv (19X2.2 ) BK X95 RMv (19X2.65 ) BK X120 RMv (19X3.05 ) BK

231 ESUY COPPER CONDUCTORS / POWER bare copper Application: temperature, in motion/ during installation Bending radius, moving application fine stranded acc. to VDE 0283 T.3 PVC VDE /IEC C 12 x DA Earthing cable with braided fine-wire conductor core for use in portable earthing and short circuit-devices, particularly for repair work on highvoltage systems for the safety of technical personnel X16 TR X25 TR X35 TR X50 TR X70 TR X95 TR X120 TR X150 TR X185 TR X240 TR ELECTRONIC CONDUCTOR ROPES COAXIAL LAN 231

232 POWER THERMAL AND COMPENSATION CONDUCTORS Thermal and compensation conductors are used in measurement and control technologies to connect temperature sensors with measurement devices. Item nr. Type Code letter Material combination / sheath material LiY(St)Y 02X1,5 K NiCr/Ni PVC/PVC Li2G2G 02X1,5 K NiCr/Ni Silicone, Silicone Li7YC7Y 01X2X0,75 K SoNiCr/SoNi ETFE/ETFE Li7YC7Y 02X2X0,75 K SoNiCr/SoNi ETFE/ETFE LiYYSY 24X1,5 L Fe/CuNi PVC/PVC ELECTRONIC Li2G2G 02X1,5 L Fe/CuNi Silicone, Silicone Li7YC7Y 01X2X0,75 L Fe/CuNi ETFE/ETFE Li7YC7Y 02X2X0,75 L Fe/CuNi ETFE/ETFE LiY(St)Y 02X1,5 J Fe/CuNi PVC/PVC Li2G2G 02X1,5 J Fe/CuNi Silicone, Silicone Li2G2G 02X1,5 RCB/SCB PtRh10/Pt Silicone, Silicone LAN Li2G2G 04X1,5 K NiGr/Ni Silicone, Silicone CONDUCTOR ROPES COAXIAL 232

233 POWER DIN DIN IEC 584 Temperature range Wire colour +/- Sheath colour X C WS/GN GN 7,3 76,0 X C WS/GN GN 7,0 76,0 X C WS/GN GN 6,4 110,0 X C WS/GN GN 7,3 130,0 X C RT/BL BL 25,0 893,0 X C RT/BL BL 7,1 76,0 X C RT/BL BL 6,4 110,0 ELECTRONIC X C RT/BL BL 7,0 130,0 X C WS/SW SW 7,5 76,0 X C WS/SW SW 7,2 76,0 X C OR/WS OR 7,1 76,0 X C WS/GN GN 8,7 152,0 LAN CONDUCTOR ROPES COAXIAL 233

234 NOTES COAXIAL LAN ELECTRONIC CONDUCTOR ROPES POWER 234

235 POWER ELECTRONIC TYPE DESIGNATION CODE FOR 236 CORE IDENTIFICATION ACCORDING TO VDE CORE IDENTIFICATION ACCORDING TO VDE COLOUR CODING OF CORES ACCORDING TO DIN AND DIN IEC COLOUR CODING OF CORES ACCORDING TO VDE SELECTION GUIDE FOR DRAG CHAIN 243 PROPERTIES OF INSULATING AND SHEATH MATERIALS 244 SIZES OF CABLE DRUMS 246 LEGEND OF ICONS USED IN CATALOGUE 247 ABBREVIATIONS FOR COLOURS USED IN CATALOGUE 249 TYPE INDEX 250 ARTICLE INDEX 255 TERMS OF DELIVERY AND PAYMENT 272 LAN COAXIAL

236 POWER TYPE DESIGNATION CODE FOR Power cables acc. to VDE 0250 Harmonized cables acc. to VDE 0281/ ELECTRONIC LAN COAXIAL 1. RELATIONSHIP TO STANDARDS N... VDE-type (N)/X... Based on VDE 2. INSULATING MATERIALS Y... PVC 4Y... Polyamide 5Y... PTFE 6Y... FEP 9Y... Polypropylene 11Y... Polyurethane (PUR) 2X... XLPE G... Elastomer 2G... Silicone 3G... EPR-rubber 4G... EVA 5G... Polychloroprene HX... LSOH 3. CABLE DESCRIPTION A... Single core D... Solid wire AF... Single core, fine stranded F... Copper conductor L... Fluorescent tube cable LH... Connecting cable for low mechanical stress MH... Connecting cable for medium mechanical stess SH... Connecting cable for high mechanical stress SSH... Connecting cable for special mechanical stress SL... Control/welding cable S... Control cable LS... Light control cable FL... Flat cable Si... Silicone cable Z... Twin cable GL... Glass fibre Li... Stranded wires acc to. VDE 812 LiF... Fine stranded wires acc. to VDE SPECIAL CONSTRUCTIONS T... Supporting element ö... Oil-resistant u... Flame-resistant w... Heat-/weather-resistant FE... Fire-resistant C... Screen S... Steel armoured 5. SHEATHING MATERIALS See 2. materials P... Polyurethane 6. PROTECTIVE CONDUCTOR -O... Without green/yellow core -J... With green/yellow core 7. NUMBER OF CORES 1. RELATIONSHIP TO STANDARDS H... Harmonized type (HAR) A... Authorised national standards 2. NOMINAL VOLTAGE V /300 V /500 V /750 V /1000 V 3. INSULATING MATERIALS V... PVC V2... PVC (90 C) V3... PVC, cold-resistant B... EPR-rubber (90 C) G... EVA E... PE R... Natural or synthetic rubber S... Silicone rubber X... XLPE Z... LSOH compound zz... Halogen-free compound (solar cable) 4. SHEATHING MATERIALS V... PVC V2... PVC (90 C) V3... PVC, cold-resistant V4... PVC, cross-linked V5... PVC, oil-resistant R... Natural or synthetic rubber N... Chloroprene rubber N2... Chloroprene rubber for welding cables N4... Chloroprene rubber, heat-resistant N8... Chloroprene rubber, water-resistant J... Glass fibre braid T... Textile braid Q... Polyethurane (PUR) Q4... Polyamide Z... LSOH compound 5. SPECIAL CONSTRUCTIONS C... Concentric copper conductor C4... Copper braided screen H... Flat, divisible cords H2... Flat cable, non divisible cords H6... Flat cable, non divisible cords for elevators H8... Spiral cable 6. CONDUCTOR FORM U... Round, solid R... Round, stranded K... Fine stranded, fixed installation F... Fine stranded, flexible cords H... Extra finely stranded, highly fexible Y... Tensile conductor D... Fine stranded for welding cables E... Extra finely stranded for welding cables, highly fexible 7. NUMBER OF CORES 8. PROTECTIVE CONDUCTOR X... Without green/yellow core G... With green/yellow core 8. CROSS-SECTION OF CONDUCTOR 9. CROSS-SECTION OF CONDUCTOR 236

237 POWER Telecounication cables acc. to VDE 0815/16 Power cables acc. to VDE RELATIONSHIP TO STANDARDS A... Outdoor cable G... Mining cable J... Installation cable L... Insulated cord S... Patchcord Li... Equipment wire with fine stranded conductor RD... Rhenomatic cable RE... Instrumentation cable 2. ADDITIONAL SPECIFICATIONS B... Lightning protection J... Induction protection E... Industry electronics 3. INSULATING MATERIALS Y... PVC 2Y... Polyethylen 02Y... Cell-PE 02YS... Foam-Skin 5Y... PTFE (Teflon ) 6Y... FEP (Teflon ) 7Y... ETFE (Teflon ) P... Paper 4. SPECIAL CONSTRUCTION F... Petroleum jelly filler L... Aluminium sheath LD... Corrugated aluminium sheath (L)... Laminated aluminium sheath C... Copper braided screen (St)... Screen of plastic coated aluminium foil (K)... Copper tape screen (B)... Armouring (Z)... Steel wire armouring (Zg)... Strain bearing element with glass yarn bundles (ZN)... Strain bearing element nonmetallic W... Corrugated steel sheath M... Lead sheath b... Armouring c... Jute jacket+ bituminous compound E...Compound with embedded tape 5. SHEATHING MATERIALS See 3. materials 6. NUMBER OF ELEMENTS Number of stranding elements 7. STRANDING ELEMENTS 1... Single core 2... Pair 4... Quad 8. CONDUCTOR DIAMETER 9. TYPE OF STRANDING F... Star-quad (railway) St... Star-quad (phantom circuit, long distance) St I... Star-quad (long distcance) St III... Star-quad (subscriber lane) TF... Star-quad for carrier frequency PiMF... Pair in metal foil DIMF... Triple in metal foil ViMF... Quad in metal foil 1. RELATIONSHIP TO STANDARDS N... VDE-type 2. CONDUCTOR -... Copper A... Aluminium 3. INSULATING MATERIALS Y... PVC 2Y... PE 2X... XLPE H... LSOH compound 4. CONCENTRIC CONDUCTOR C... Longitudinal lay CW... Undulated 5. SCREEN S... Joint copper shield SE... Individually screened cores 6. METAL SHEATH K... Lead 7. PLASTIC SHEATH OR INNER PROTECTION 8. ARMOURING See 3. materials F... Flat steel wire R... Round steel wire G... Steel tape 9. OUTER SHEATH See 3. materials 10. PROTECTIVE CONDUCTOR -J... With green/yellow core -O... Without green/yellow core 11. NUMBER OF CORES 12. CONDUCTOR FORM RE... Round, solid RM... Round, stranded SE... Sector shaped, solid SM... Sector shaped, stranded ELECTRONIC LAN COAXIAL 10. STRANDING LAYOUT Lg... Stranding in layers Bd... Stranding in bundles 237

238 POWER CORE IDENTIFICATION ACCORDING TO VDE COLOUR CODING FOR INSTALLATION ELECTRONIC J-Y(St)Y... Lg For single-paired cables a-core red, b-core blue For double-paired cables Pair 1: a-core red, b-core black Pair 2: a-core white, b-core yellow For cables with more than 2 pairs The colour of the a-core in the first pair of each layer is red ( counting pair), in all other pairs it is white. The colour of the b-core is blue, yellow, green, brown, black in repeating order as follows: Colour of b-core No. of pair blue yellow green brown black blue yellow green brown black COLOUR CODING FOR INSTALLATION JE-Y(St)Y... Bd / JE-LiYCY... Bd / JE-H(St)H... Bd / JE-LIHCH... Bd / RD-Y(St)Y / AJ-Y(St)YDY Bd Si LAN COAXIAL For double-paired cables Pair 1: a-core blue, b-core red Pair 2: a-core grey, b-core yellow For cables with more than 2 pairs Colour of basic insulation of pairs in one bunch: Pair Core a b a b a b a b Basic colour blue red grey yellow green brown white black For identification of bunches, cores are marked with black rings and bunches are wrapped by a coloured tape. Ring group I Ring group II Ring group III Ring group IV 238

239 CORE IDENTIFICATION ACCORDING TO VDE 0815 POWER IDENTIFICATION OF BUNCHES Bunch-No. Colour of rings Rings of bunches of Tape 4 cores 8 cores resp. 4 pairs pink I I II II I II III IV orange violet I II III IV I II III IV pink orange I II III IV I II III IV blue red ELECTRONIC 3. COLOUR CODING FOR INSTALLATION J-YY... Bd / J-H(St)H... Bd / J-2Y(St)Y St III Bd LAN The five star-quads of each bunch have the following identification: 1. Basic insulation of all cores red 2. Basic insulation of all cores green 3. Basic insulation of all cores grey 4. Basic insulation of all cores yellow 5. Basic insulation of all cores white The cores within one star-quad are marked by rings: a - c o r e b - c o r e a - c o r e b - c o r e side circuit 1 side circuit 2 COAXIAL The counting bunch is marked by a red tape in each layer. All other bunches have a white or a natural-coloured tape

240 POWER CORE IDENTIFICATION ACCORDING TO VDE CORE IDENTIFICATION FOR OUTDOOR TELEPHONE The five star-quads of each basic unit have the following identification: Quad 1. Basic insulation of all cores red Quad 2. Basic insulation of all cores green Quad 3. Basic insulation of all cores grey Quad 4. Basic insulation of all cores yellow Quad 5. Basic insulation of all cores white ELECTRONIC The basic insulation of spare quads is red. The cores within one star-quad are marked by rings: a - c o r e b - c o r e a - c o r e b - c o r e side circuit 1 side circuit 2 The first basic or main unit in each layer is to be marked by an open helix of plastic tape of red (marker). All other basic or main units must be wrapped with an open helix of white or uncoloured plastic tape. The quads of a basic unit are to be counted according to the sequence of basic colours. In cables with more than 5 star-quads, the basic and main units must be counted continuously beginning with marker unit at inner layer towards outside. LAN EXAMPLE FOR UNIT STRANDING COAXIAL 1 star-quad 1 star-quad 1 basic unit 5 star-quads stranded into basic unit 5 basic units each stranded into one main unit =

241 COLOUR CODING OF CORES ACCORDING TO DIN AND DIN IEC POWER The colour code according to table 1 without repeating colours from core 46 resp. pair 23 is used for electronic cables LiYY, LiYCY and similar types. Counting of cores starts in the outer layer of the strand and is continued through all layers in the same direction. The first colour in the table is the colour of insulation, the second and third ones are printed rings. Table 1 Table 2 contains German and English abbreviations for colours acc. to IEC (The table does not correspond to any order of colours/cores in a cable!) Colour Stranded cores Twisted pairs Core-No. Core Pair-No. white 1 a brown 2 b green 3 a yellow 4 b grey 5 a pink 6 b blue 7 a red 8 b black 9 a violet 10 b grey/pink 11 a red/blue 12 b white/green 13 a brown/green 14 b white/yellow 15 a yellow/brown 16 b white/grey 17 a grey/brown 18 b white/pink 19 a pink/brown 20 b white/blue 21 a brown/blue 22 b white/red 23 a brown/red 24 b white/black 25 a brown/black 26 b grey/green 27 a yellow/grey 28 b pink/green 29 a yellow/pink 30 b green/blue 31 a yellow/blue 32 b green/red 33 a yellow/red 34 b green/black 35 a yellow/black 36 b grey/blue 37 a pink/blue 38 b grey/red 39 a pink/red 40 b grey/black 41 a pink/black 42 b Colour Stranded cores Twisted pairs Core-No. Core Pair-No. blue/black 43 a red/black 44 b white/brown/black 45 a yellow/green/black 46 b grey/pink/black 47 a red/blue/black 48 b white/green/black 49 a brown/green/black 50 b white/yellow/black 51 a yellow/brown/black 52 b white/grey/black 53 a grey/brown/black 54 b white/pink/black 55 a pink/brown/black 56 b white/blue/black 57 a brown/blue/black 58 b white/red/black 59 a brown/red/black 60 b black/white 61 Table 2 Colour German abbreviation Colour black SW black BK brown BR brown BN red RT red RD orange OR orange OG yellow GE yellow YE green GN green GN blue BL blue BU violet VI violet VT grey GR grey GY white WS white WH pink RS pink PK gold gold GD turquoise TK turquoise TQ silver silver SR green/yellow GG green-yellow GNYE English abbreviation ELECTRONIC LAN COAXIAL 241

242 POWER COLOUR CODING OF CORES ACCORDING TO VDE /CORDS WITH GN-YE PROTECTIVE CONDUCTOR Version No. of cores DIN VDE :2003 Fixed and flexible gn-ye, bu, bn 3 ELECTRONIC with gn-ye (-J) or G 4 5 gn-ye, bn, bk, gy gn-ye, bu, bn, bk, gy bu = blue, bn = brown, gn-ye = green-yellow, gy = grey. bk = black 2. /CORDS WITHOUT GN-YE PROTECTIVE CONDUCTOR LAN Version No. of cores DIN VDE :2003 Fixed and flexible bu, bn 2 COAXIAL without gn-ye 3 bn, bk, gy 3 ½ bu, bn, bk, gy (-O) or X 4 5 bu, bn, bk, gy bu, bn, bk, gy, bk bu = blue, bn = brown, gn-ye = green/yellow, gy = grey. bk = black 242

243 POWER SELECTION GUIDE FOR DRAG CHAIN Isulation/sheath Screen Page 1. ELECTRONIC FABER EFK Li9YC11Y PP/PUR BUS CAN-Bus EFK Profibus EFK DeviceNet EFK Interbus EFK ELECTRONIC 3. FEEDBACK CABLE FABER EFK Feedback-CP INDRAMAT TPE/PUR FABER EFK Feedback-CP Siemens PP/PUR NETWORK CABLE FABER Industrial dataline + 5. CONTROL LAN FABER EFK 250 P PVC/PUR - FABER EFK 300 P PP/PUR FABER EFK 300 CP PP/PUR FABER EFK 310 Y PVC/PVC COAXIAL FABER EFK 310 CY PVC/PVC SERVO FABER EFK SERVO-CP INDRAMAT TPE/PUR FABER EFK SERVO-CP Siemens PP/PUR SINGLE CORES FABER EFK SC 12Y11Y TPE/PUR FABER EFK SC 12YC11Y TPE/PUR Legend: PVC Polyvinylchloride, TPE Thermoplastic elastomer, PP Polypropylene, PUR Polyurethane 243

244 POWER PROPERTIES* OF INSULATING AND SHEATH MATERIALS VDE des. Designation Electrical Thermal Code Material Density g/cm³ Electr. Strength kv/ Specific insulation resistance Ω cm 20 C Dielectr. Coeffi cient 50 Hz/ 20 C Tangent of loss angle tan Service temperature Melting point Burning behaviour contin. C Oxygen LOI Heating value Ho short C + C (% O 2 ) MJ kg -1 THERMOPLASTICS ELECTRONIC Y Yw Yw PVC PVC PVC Polyvinylchloride mixture Temperatureresistance 90 C Temperatureresistance 105 C Yk PVC Cold-resistance x10-2 up to 1x Y LDPE PE (low density) x Y HDPE PE (high density) x X VPE Cross-linked polyethylene 0, x O2Y Polyethylene foam ~ ~1.55 5x Y PS Polystyrene x Y PA Polyamide x10-2 bis 1x Y PP Polypropylene x Y PUR Polyurethane x TPE-E (12Y/ 13Y) TPE-O (18Y) Polyester elastomer > x Polyolefin elastomer ,0 30 > x > > 140 self ex tin > 140 g uishing > > combus tible ELASTOMERS LAN COAXIAL G NR SBR Natural rubber styrene-butadiene rubber mixture x G SIR Silicone rubber x G 4G 5G EPR EVA CR Ethylene propylene mixture Ethylene vinyl acetate copolymer mixture Polychloroprene mixture 6G CSM Chlorosulfunated polyethylene mixture HIGH-TEMPERATURE MATERIALS 10Y 7Y 6Y PVDF ETFE FEP Polyvinylidene fluoride Kynar / Dyflor Ethylen tetrafluorethylene Tefzel Perfluorethylenpropylene Teflon ,8 3.4x ,5 2x ,5 5x x x x x YX PFA Perfluoralkoxy Teflon x Y PTFE Polytetrafluorethylene Teflon HALOGEN-FREE MIXTURES H HX Crosslinked Crosslinked Halogen-free polymer mixture Halogen-free polymer mixture x ~ combus tible low flaability combus tible self ex tin g uishing > > > 225 non combustible > > > 130 self ex tin g uishing * Properties apply to unprocessed material 244

245 POWER VDE des. Designation Thermal Mechanical Code Material Thermal conductivity W K -1 -m -1 Corrosive gases in case of fire Radiationresistance max. Mrad Tensile strength N/² Breaking strain % Shore- Hardness Water absorp tion % Halogen- Free Halogenfree Wheatering Abrasion performance Weatheringresistance Low temper. performance THERMOPLASTICS Y PVC Polyvinyl chloride mixture Yw Yw Yk 2Y 2Y PVC PVC PVC LDPE HDPE Temperatureresistance 90 C Temperatureresistance 105 C Low temperatureresistance PE (low density) PE (high density) Hydrogen chloride (A) average 0.4 no (D) average (D) good yes 2X VPE Cross-linked polyethylene (D) average good O2Y Polyethylene foam restrict 1) 3Y PS Polystyrene (D) good 0.4 mod. good in black mod. good no 4Y PA Polyamide very good good 10 9Y PP Polypropylene (D) average 0.1 mod. good mod. good very good good mod. good good ELECTRONIC 11Y PUR Polyurethane (500) TPE-E (12Y/13Y) TPE-O (18Y) Polyester elastomer 0.5 Polyolefin elastomer > (A) 85 (A) 70 (D) 55 (A) 70 (D) very good good yes 1.5 very good very good ELASTOMERS G NR SBR Natural rubber styrenebutadiene rubber mixture 2G SIR Silicone rubber (A) 3G 4G 5G EPR EVA CR Ethylene propylene mixed polymer mixture Ethylene vinyl acetate copolymer mixture Polychloroprene mixture 6G CSM Chlorosulfunated polyethylene mixture no (A) mod. 1.0 no mod. good (A) yes very good (A) good Hydrogen chloride (A) average 1.0 no good very good very good good mod. good (A) 1.5 mod. good LAN COAXIAL HIGH-TEMPERATURE MATERIALS 10Y 7Y 6Y PVDF ETFE FEP Polyvinyl Fluoride Kynar /Dyflor Ethylen tetra fluorethylene Tefzel Perfluorethylen propylene Teflon 0.17 Hydrogen fluoride (D) 0.24 ja (D) ja (D) very good 0.01 no very good very good 5YX PFA Perfluoralkoxy Teflon 0.21 ja (D) 5Y PTFE Polytetrafluorethylene Teflon HALOGEN-FREE MIXTURES H HX Crosslinked Crosslinked Halogen-free polymer mixture Halogen-free polymer mixture 0.26 ja (D) 0.17 no no (A) average yes * Properties apply to unprocessed material / 1) Propellants, for example, may consist of or contain fluorinated hydrocarbons (HCDCs) mod., good in black average

246 POWER SIZES OF CABLE DRUMS PLASTIC DRUMS In addition to the below-listed drums (according to DIN ) we may also use drums made to various manufacturer standards, with dimensions in between the listed values. In such case our calculation of the deposit value will be based on the next DIN size up. Nominal size Flange diameter () Barrel diameter () Overall width () Drum weight (kg) , WOODEN STANDARD DRUMS ELECTRONIC LAN Nominal size Flange diameter () Barrel diameter () Overall width () Drum weight (kg) , , , , , ,800 1,000 1, ,000 1,250 1, ,240 1,400 1, ,400 1,400 1, ,500 1,600 1, ,600 1,600 1, ,800 1,800 1,635 1,175 COAXIAL WOODEN DRUMS WITH ARMOURED FLANGES Nominal size Flange diameter () Barrel diameter () Overall width () Drum weight (kg) , , , , , ,800 1,000 1, ,000 1,000 1, ,000 1,250 1, ,240 1,120 1, ,240 1,400 1, ,500 1,400 1, ,500 1,250 1, ,800 1,800 1,635 1,

247 LEGEND OF ICONS USED IN CATALOGUE POWER Min. installation temperature -30 C Cable with VDE-certification Min. installation temperature -35 C Harmonised cable/wire Min. installation temperature -40 C Cable with UL/CSA-certification Cable with TÜV-approval Cable with VdS-approval Max. permitted temperature at conductor 60 C Max. permitted temperature at conductor 70 C Max. permitted temperature at conductor 80 C ELECTRONIC Cable with EAC-approval Cable with CCC-approval Max. permitted temperature at conductor 85 C Max. permitted temperature at conductor 90 C Cable conform to Low-Voltage Directive Cable is conform with DESINA standard Min. installation temperature +5 C Max. permitted temperature at conductor 110 C Max. permitted temperature at conductor 120 C Max. permitted temperature at conductor 125 C LAN COAXIAL Min. installation temperature 0 C Min. installation temperature -5 C Max. permitted temperature at conductor 145 C Max. permitted temperature at conductor 180 C Min. installation temperature -20 C Max. permitted temperature at conductor 200 C Min. installation temperature -25 C Self-supporting cable 247

248 POWER LEGEND OF ICONS USED IN CATALOGUE Cable suitable for direct burial Cable tender system Installation outdoors only with UV-protection (cable not UVresistant) Cylindric drum Installation outdoors without protection (cable UV-resistant) Guide pulley system Cable for use in water Cable to a large extent oil-resistant Festoon cable Monospiral reeling ELECTRONIC Not for application in power circuits Multispiral reeling Screened cable Cable halogen-free Cable suitable for drag chains Reelable cable LAN acc. to IEC Vertical reeling COAXIAL acc. to IEC Low smoke cable Cable category 5 Cable category 5e Cable with isolation integrity 180 min. Cable with circuit integrity 30 min. Cable category 7 Cable category 7+ Cable with circuit integrity min. Cable metal-free (optical fibre) Cable with circuit integrity 90 min. Cable with rodent protection (optical fibre) 248

249 ABBREVIATIONS FOR COLOURS USED IN CATALOGUE POWER B1 dark blue/white BE beige BL blue BR brown BT brown/transparent BW blue/white DB dark blue DG dark green DH dark blue/high grade DW dark blue/white GE yellow GG green/yellow GN green GR grey HB light blue KG pine-green MG pink NT natural ELECTRONIC OB ocean-blue OF without colour OH orange/high grade OR orange LAN PT petrol PW white R1 red/white RS pink COAXIAL RT red SG grey SH black/high grade SW black TB turquoise TR clear transparent VI violet VL violet WO white/orange WS white 249

250 POWER TYPE INDEX ELECTRONIC LAN COAXIAL 2 A C 2GTL 13.8/15 kv 105 2YSL(St)CYv 161 A-2YF(L)2Y A-2YF(L)2Y A-2YF(L)2YB2Y... St III Bd 127 A-2YK2Y1 ikx 1,1/7,3 219 A-2Y(L)2Y A-2Y(L)2Y A-2YOK2Y1 nkx 2,2/8,8 219 A-2YOK2Y1 qkx 3,3/13,5 219 A-2YOK2Y1 skx 4,9/19,4 219 A-02YSF(L)2Y... St III Bd 127 A-02YSOF(L)2Y A-02YS(St)(Zg)2Y A05RN-F 95 A-DQ(ZN)B2Y 1.2 kn (Central core) 223 A-DQ(ZN)B2Y 2.2 kn (Central core) 222 A-DQ(ZN)B2Y Plus 3.0 kn (Central core) 223 A-DQ(ZN)B2Y (Stranded cores) 224 AES/EBU & DMX STCY 04X0, AES/EBU & DMX STDY 02X0, AJ-Y(St)YDY Bd 129 A-Y(St)Yoe 129 CAN-Bus BURIAL YY CUL CMX UV- BEST. 02X2X0,75 CAN-Bus-EFK PUR UL/CSA 01X2X0,5 CAN-Bus-EFK PUR UL/CSA 02X2X0,5 CAN-Bus-EFK PUR UL/CSA 02X2X0,25 CAN-Bus-EFK PUR UL/CSA 02X2X0, CAN-Bus-FIX PVC UL/CSA 01X2X0,5 179 CAN-Bus-FIX PVC UL/CSA 01X2X0,22 CAN-Bus-FIX PVC UL/CSA 01X2X0,34 CAN-Bus-FIX PVC UL/CSA 01X2X0, CAN-Bus-FIX PVC UL/CSA 02X2X0,5 179 CAN-Bus-FIX PVC UL/CSA 02X2X0,22 CAN-Bus-FIX PVC UL/CSA 02X2X0,34 CAN-Bus-FIX PVC UL/CSA 02X2X0,75 Copper conductor, soft annealed, bare, compacted Copper conductor, soft annealed, tinned D E F DeviceNet (TM) Bus FRNC 01X2X AWG X2X AWG 15 EFK UL DeviceNet (TM) Bus FRNC 01X2X AWG X2X AWG 22 EFK UL ESUY 231 FABER 100 F-CP 168 FABER 100 P 167 FABER AS-Interface BUS PUR 02X1,5 FABER AS-Interface BUS PUR 02X2,5 FABER AS-Interface BUS Rubber 02X1,5 FABER AS-Interface BUS Rubber 02X1,5 FABER AS-Interface BUS TPE 02X1, FABER dataline FABER dataline FABER dataline FABER dataline 1000 duplex 214 FABER dataline 1000 outdoor 215 FABER EFK 300 CP (Drag chain cable) FABER EFK 300 P (Drag chain cable) FABER EFK 310 CY (Drag chain cable) FABER EFK 310 Y (Drag chain cable) FABER EFK AS-Interface BUS PUR 02X1,5 FABER EFK AS-Interface BUS PUR 02X1,5 FABER EFK Feedback-CP Indramat (Drag chain cable)

251 TYPE INDEX POWER G H FABER EFK Feedback-CP Siemens (Drag chain cable) FABER EFK Li9YC11Y (Drag chain cable) FABER EFK Servo-CP Indramat (Drag chain cable) FABER EFK Servo-CP Siemens (Drag chain cable) FABER EFK Single core 12Y11Y (Drag chain cable) FABER EFK Single core 12YC11Y (Drag chain cable) FABER EIB-bus cable 02X2X0,8 178 FABER EIB-bus cable 04X2X0,8 178 FABER EIB-bus cable direct burial 02X2 X0,8 FABER EIB-bus cable halogen-free 02X2X0,8 FABER HD-SAT 1,0/4,6 DIGITAL 3-S > 115 db FABER HD-SAT 1,0/4,6 DIGITAL 3-S > 115 db halogen-free FABER Jalousie FRNC 96 FABER SAT 1,1/5,0 DIGITAL 3 GHz 219 FABER SAT 1,1/5,0 halogen-free DIGITAL 3 GHz 219 FABER THERM FABER THERM 145 (Single core) 113 FABER VIDEO 0,6/3,7 219 FABER VIDEO flexible 0,6L/3,7 219 FABER VIDEO halogen-free 0,6/3,7 219 FABER VIDEO Outdoor cable 1,0/6,6 219 Fire signalisation cable 119 FOUNDATION FIELDBUS 01X2XAWG 18/7 179 FZLSi 105 GGSG 93 H01N2-D - Cable with normal flexibility 87 H1Z2Z2-K 87 H03VV-F 79 H05BQ-F 98 H05RN-F 83 H05RNH2-F 93 H05RR-F 83 I J H05SJ-K 103 H05SS-F 110 H05SS-F (UL) 111 H05V-K 71 H05V-U 70 H05VV5-F 155 H05VVC4V5-K 156 H05VV-F 79 H05Z1Z1-F 80 H05Z-K 76 H07BQ-F (without filler) 98 H07RN-F 84 H07V-K 74 H07V-R 73 H07V-U 72 H07VVH6-F 169 H07Z-K 77 H07ZZ-F 86 HD-SAT+BK PE direct burial 1,6/7,3 DIGITAL 3-S >100 db 219 HSLCH-JZ 164 HSLCH-OZ 165 HSLH-JZ 162 HSLH-OZ 163 I-D(ZN)H 225 Intercounication bus cable FRNC 02X1,5 sq + L-2Y 02X2X0,6 Intercounication bus cable LiY 02X1,5 sq + L-2Y 02X2X0, I-V(ZN)H 226 I-Y(St)Y... Lg 118 I-YY 118 J-2Y(St)H... St III Bd 122 J-2Y(St)Y... St III Bd 121 JE-H(St)H FE180/E JE-H(St)H FE180/E30-E JE-H(St)H FE180/E30-E90 Fire signalisation cable JE-H(St)H FE180/E30 Fire signalisation cable ELECTRONIC LAN COAXIAL 251

252 POWER TYPE INDEX ELECTRONIC LAN COAXIAL L N JE-H(St)HRH FE180/E30-E90 Fire signalisation cable 209 JE-LiHCH 142 JE-LiYCY 141 JE-Y(St)Y 138 JE-Y(St)Y... FR 140 JE-Y(St)Yv 139 J-H(ST)H 120 J-H(St)H Fire signalisation cable 121 Li2G2G 02X1,5 233 Li2G2G 02X1,5 233 Li2G2G 02X1,5 233 Li2G2G 02X1,5 233 Li2G2G 04X1,5 233 Li2GYw (SiHYw PV/P) 112 Li2YCY PiMF 193 Li2YCYv 176 Li7YC7Y 01X2X0, Li7YC7Y 01X2X0, Li7YC7Y 02X2X0, Li7YC7Y 02X2X0, LiHCH 175 Livz6YYw 112 LiYCY 172 LiYCY/EB 174 LiYCY/EB TP 175 LiY(St)Y 02X1,5 233 LiY(St)Y 02X1,5 233 LiYY 170 LiYY/EB 171 LiYYSY 24X1,5 233 N2XCH 31 N2XCH (B2ca) 35 N2XH-J 28 N2XH-J (B2ca) 32 N2XH-O 30 N2XH-O (B2ca) 34 N2XS2Y 6/10 kv 45 N2XS2Y 12/20 kv 46 N2XS2Y 18/30 kv 47 N2XSEY 6/10 kv 60 N2XS(F)2Y 6/10 kv 51 N2XS(F)2Y 12/20 kv 52 N2XS(F)2Y 18/30 kv 53 N2XS(FL)2Y 6/10 kv 57 N2XS(FL)2Y 12/20 kv 57 N2XSY 6/10 kv 39 N2XSY 12/20 kv 40 N2XSY 18/30 kv 41 NA2X2Y-J 36 NA2XS2Y 6/10 kv 48 NA2XS2Y 12/20 kv 49 NA2XS2Y 18/30 kv 50 NA2XS(F)2Y 6/10 kv 54 NA2XS(F)2Y 12/20 kv 55 NA2XS(F)2Y 18/30 kv 56 NA2XS(FL)2Y 6/10 kv 58 NA2XS(FL)2Y 12/20 kv 59 NA2XS(FL)2Y 18/30 kv 59 NA2XSY 6/10 kv 42 NA2XSY 12/20 kv 43 NA2XSY 18/30 kv 44 NA2XY-J 37 NAY2Y-J 38 NAYCWY 25 NAYY-J 21 NAYY-O 22 NFA2X 61 NGFLCGOEU 95 NGFLGOEU 94 (N)HXCH E (N)HXCH E (N)HXCH Plus 202 (N)HXH-J E (N)HXH-J E (N)HXH-J Plus 201 (N)HXH-O E (N)HXH-O E (N)HXH-O Plus

253 TYPE INDEX POWER P NHXMH-J 67 (N)HXMH(St)-J 68 NSGAFOEU 1.8/3 kv 96 NSHTOEU 91 NSHXAFOE 1.8/3 kv 78 NSSHOEU /3E 90 NSSHOEU-J 88 NSSHOEU-O 89 (N)TMCGCWOEU 12/20 kv 115 (N)TSCGEWOEU MT PLUS 12/20 kv 115 NYCWY 23 NYCY 24 NYFGY 3.6/6 kv 27 NYIF-J 67 NYL 113 NYM-J 64 NYM-O 65 (N)YM(St)-J 66 NYY-J 16 NYY-JZ 19 NYY-O 18 (N)YYoek-J 36 NYY-OZ 20 (N)Y(Zg)2Y 26 Profibus direct burial L2/FIP/DP/ FMS 2Y(St)CY2Y 01X2X0,64 Profibus EFK PUR FC L2/FIP/DP/ FMS - 19 Strand 01X2X0,64 Profibus EFK PUR L2/FIP/DP/FMS - 19 Strand 01X2X0,64 Profibus Fast Connect L2/FIP/DP/ FMS 2YY(St)CY 01X2X0,64 Profibus Fast Connect L2/FIP/DP/ FMS 2YY(St)CY 01X2X0,64 Profibus Festoon PVC L2/FIP/DP/ FMS - 19 Strand 01X2X0,64 Profibus FRNC L2/FIP/DP/FMS 2Y(St)CH 01X2X0,64 Profibus FRNC L2/FIP/DP/FMS 2Y(St)CH 01X2X0,64 Profibus PA UL/CSA FR 01X2XAWG 18/7 Profibus PA UL/CSA FR 01X2XAWG 18/7 Profibus PVC L2/FIP/DP/FMS 2Y(St) CY 01X2X0, R S U V Profibus PVC L2/FIP/DP/FMS Fast Connect, cul 01X2X0,64 Profibus PVC L2/FIP/DP/FMS Fast Connect, cul 01X2X0,64/7 Profibus UL/CSA L2 FIP/DP/FMS 2Y(St)CY 01X2X0, RD-H(St)H 131 RD-Y(St)Y 130 RD-Y(St)Yv 131 RD-YwCYw 137 RE-2X(St)Yv-fl 132 RE-2X(St)Yv-fl PiMF 133 RE-2Y(St)Yv 0.5 sq 134 RE-2Y(St)Yv 0.75 sq 135 RE-2Y(St)Yv 1.3 sq 136 RG 11 A/U 218 RG 58 C/U 218 RG 58 C/U FRNC 218 RG 59 B/U 218 RG 59 B/U FRNC 218 RG 62 A/U 218 RG 174 A/U 218 RG 179 B/U 218 RG RG 214 /U 218 SiD 101 SiF 102 SiF/GL 104 SiHFC-Si-J/-O 108 SiHF/GLS-P 109 SiHF-J 106 SiHF-O 107 Submersible pump cable (-J) 92 U-DQ(ZN)BH 227 Video SDI/HD 0,8/3,7 + 02X0, ELECTRONIC LAN COAXIAL

254 POWER TYPE INDEX X X07BQ-F (with filler) 100 X07BQ-F (without filler) 99 ELECTRONIC LAN Y YFAZ 82 YR 143 YSLCY-JZ 154 YSLCY-OZ 155 YSLYCY-JB 153 YSLYCY-JZ 151 YSLYCY-JZ YSLYCY-OZ 152 YSLYCY-OZ YSLY-JB 149 YSLY-JZ 146 YSLY-JZ YSLY-OB 150 YSLY-OZ 148 YSLY-OZ YSLYSY-JZ 165 YSLYSY-OZ 166 COAXIAL 254

255 ARTICLE INDEX POWER p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

256 POWER ARTICLE INDEX p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

257 ARTICLE INDEX POWER p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

258 POWER ARTICLE INDEX p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

259 ARTICLE INDEX POWER p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

260 POWER ARTICLE INDEX p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

261 ARTICLE INDEX POWER p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

262 POWER ARTICLE INDEX p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

263 ARTICLE INDEX POWER p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

264 POWER ARTICLE INDEX p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

265 ARTICLE INDEX POWER p/n page p/n page p/n page p/n page p/n page p/n page p/n page ELECTRONIC LAN COAXIAL

266 NOTES COAXIAL LAN ELECTRONIC POWER 266

267 NOTES COAXIAL LAN ELECTRONIC POWER 267

268 NOTES COAXIAL LAN ELECTRONIC POWER 268

269 NOTES COAXIAL LAN ELECTRONIC POWER 269

270 NOTES COAXIAL LAN ELECTRONIC POWER 270

271 NOTES COAXIAL LAN ELECTRONIC POWER 271

272 POWER ELECTRONIC THE CURRENT TERMS OF DELIVERY AND PAYMENT CAN BE FOUNT COAXIAL LAN 272

273 REEL-IN-BOX THE BEST SOLUTION FOR DATA. The box for our product line FABER dataline is available in two designs: As a Simplex version with a cable length of 200 m and in the Duplex version with 100 m. For an easy and knot-free unreeling without an additional unreeling device. Side view Plastic reel that is fixed inside a reinforced cardboard box Box size 30 x 36 x 40 cm Total weight of around 12 kg.

274 Klaus Faber AG Headquarters Lebacher Straße Saarbrücken Germany Phone Fax Klaus Faber AG Export and logistics centre Hedemünden Kirchweg Hann. Münden Germany Klaus Faber AG Export and logistics centre Fichtenau Gärtnerstraße Fichtenau Germany Find out more:

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

Kabel CONNECTION. A partnership to your advantage.

Kabel CONNECTION. A partnership to your advantage. Kabel THE CABLE CONNECTION catalogue www.boehm-kabel.de A partnership to your advantage Four reasons......to choose Kabel We can supply to final consumers if you express the wish. Fast and reliable supply

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr For

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Silicone Push-on Accessories

Silicone Push-on Accessories Silicone Push-on Accessories RXS Kabelgarnituren GmbH & Co. KG 67 Push-on Straight Joint AMS 10, AMS 20 For 1-Conductor Polymer-Insulated Power Cables ) = 6 / 10 (12) kv; 12 / 20 (24) kv Design The AMS

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm Overview Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF898.001 CF898.045 CF898.080 & CF898.081 Example drawing 34 mm Core design: Conductor: Core insulation: Core identification:

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable According to VDE 0250 part 204 Characteristics Properties Unit Group Power cables < 1 kv Class House wiring cable Type material Cu, bare minal cross section conductor mm² Low smoke (acc. EN 61034-2) Diameter

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath Spiral cable with outer PUR sheath for exact impulse transmission, unshielded - PUR spiral cable, abrasion-resistant data and control cable for use in data processing, measurement and control engineering

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022

More information

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

CRANES & MATERIAL HANDLING CRANES & MATERIAL HANDLING WE LIFT YOUR WORLD.

CRANES & MATERIAL HANDLING CRANES & MATERIAL HANDLING WE LIFT YOUR WORLD. CRANES & MATERIAL HANDLING CRANES & MATERIAL HANDLING WE LIFT YOUR WORLD. FABER THE CABLE PROFESSIONALS. As a specialist wholesaler for cables and wires, the product portfolio we can offer our customers

More information

Technical attributes

Technical attributes Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Elettrotek Kabel Group was established in 2001 in Bagnolo. Italy,

Elettrotek Kabel Group was established in 2001 in Bagnolo. Italy, Elettrotek Kabel Group was established in 2001 in Bagnolo. Italy, born from the desire to supply specific cables to the local market, with the aim to expand worldwide. Expansion which was made possible

More information

CF11.LC / CF11.LC.D CF14.CAT5

CF11.LC / CF11.LC.D CF14.CAT5 TPE - e-chain - Bus cable for maximum load requirements (Class 6.6.4): shielded, oil- and biooil-resistant, PVC- and halogen-free as well as hydrolysis- and microbe-resistant. Overview Example drawing

More information

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

Cable systems We offer you the essential components for a future-oriented e-mobility.

Cable systems We offer you the essential components for a future-oriented e-mobility. Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

INFORMATION. Hybrid cables. Description

INFORMATION. Hybrid cables. Description Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description

More information

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools Medium voltage - Cable accessories up to 36 kv Tapes Connection technique Tools TABLE OF CONTENTS General information... 6 7 CAST RESIN-TECHNIQUE...8 11 Straight-through joints for polymeric-insulated

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation

More information

Wires that don t catch fire

Wires that don t catch fire Wires that don t catch fire Havells range of heat resistant & flame retardant wires w.e.f. 1st July, 2017 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial

More information

MOTOR, SERVO, & FEEDBACK CABLES

MOTOR, SERVO, & FEEDBACK CABLES MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

P High Voltage Catalogue Cables Australia Powering your Project

P High Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated

More information

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant. Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see the

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION fire protection halogen-free flexibility oil resistance These are the characteristics united

More information

Data sheet chainflex CF330.D

Data sheet chainflex CF330.D 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Core insulation: Mechanically high-quality TPE mixture 3. Conductor: Conductor rope in especially bending-stable version consisting of bare

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

CONTROL CABLES CABLES FZE.

CONTROL CABLES CABLES FZE. CONTROL CABLES CABLES FZE www.markcables.com Index Introduction 03 Particulars & Guarantees 05 Copper Conductor, PVC Insulated, PVC Sheathed Cables 08 Copper Conductor, XLPE Insulated, PVC Sheathed Cables

More information

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12 to RJ45 Ethernet connection line Cat.5, 4-pole, D-coded (IEC 61076-2-101) M12

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Data sheet chainflex CF340

Data sheet chainflex CF340 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Core insulation: Mechanically

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044 for medium to high load requirements. Overview Class.PVC.PUR (3D-e-chain - cable) CAT5 (4x0,25)C (4x(2x0,25))C.PVC.040.PUR.040.040 CF14.02.02.02.CAT5 34 mm.041 CF14.02.04.02.CAT5 (5x(2x0,25))C 34 mm igus

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod

Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod Z V ET L I Т Traditional reliability Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod www.zvetlit.ru Contents 1 About company 2 Analogues (according to IEC, VDE, PN, HD, BS) 4 Power

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table) Outer jacket: Pressure extruded, gusset filling PVC mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand consisting of bare copper wires Core insulation:

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

Data sheet chainflex CF5

Data sheet chainflex CF5 1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:

More information

Industrial Ethernet Cables

Industrial Ethernet Cables Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................

More information

Data sheet chainflex CF300.UL.D

Data sheet chainflex CF300.UL.D 1. Outer jacket: Pressure extruded, flame-retardant TPE mixture 2. Core insulation: Mechanically high-quality TPE mixture 3. Conductor: Conductor rope in especially bending-stable version consisting of

More information

Data sheet chainflex CF6

Data sheet chainflex CF6 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture

More information

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table) Outer jacket: Pressure extruded PVC mixture Inner jacket: Pressure extruded, gusset filling PVC mixture Conductor: Fine-wire strand consisting of bare copper wires 6 1 Core insulation: Mechanically highquality

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF270.UL.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core

More information

Data sheet chainflex CF881

Data sheet chainflex CF881 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Stranded

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

CFRIP - tear strip for faster stripping

CFRIP - tear strip for faster stripping Outer jacket: Pressure extruded, gusset filling, flame-retardant TPE mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand in especially bendingstable

More information

THERMOCOUPLE CABLES THERMOELECTRICITY

THERMOCOUPLE CABLES THERMOELECTRICITY THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,

More information