CONDUIT BOXES AND ACCESSORIES
|
|
- Janis Wilkinson
- 5 years ago
- Views:
Transcription
1 CONDUIT BOXES AND ACCESSORIES
2
3 B1 : EExd IIB PULLING FITTINGS EKC B2 : EExd IIB PULLING ELBOWS LBH B3 : EExd IIC JUNCTION AND PULLING BOXES S. B4 : EExd IIC JUNCTION BOXES WITH SUSPENSION FLANGE SF. B5 : EExd IIC SUSPENSION BOXES FOR LIGHTING FIXTURES SSC B6 : EExe JUNCTION BOXES B7 : IP65 WATERPROOF BOXES Condulets B8 : B9 : B10 : B11 : B12 : B13 : B14 : B15 : B16 : B17 : B18 :
4
5 of protection: Class of temperature: Certificate: EEx d IIB T6 ISSEP 93C U Pulling fittings EKC Entries UNI 6125 D A B C EKC 1 1/ EKC 2 3/ EKC EKC 4 1.1/ EKC 5 1.1/ EKC EKC 7 2.1/ EKC EKC Description: The EKC fittings consist of a body having two threaded entries and of a cover, with flat joint, fixed by screws. Materials: Body and cover: aluminium alloy. Screws: galvanized steel. Application: The EKC fittings are used to facilitate the insertion of not very flexible cables or of big sections and to connect pipes. On request: Other types of thread. Rev. 0 on B 1
6 LBH Pulling elbows of protection: Class of temperature: Certificate: EEx d IIB T6 ISSEP 93C U Entries D A B C E LBH 1 1/ LBH 2 3/ LBH LBH 4 1.1/ LBH 5 1.1/ LBH LBH 7 2.1/ LBH LBHF 1 1/ LBHF 2 3/ LBHF LBHF 4 1.1/ LBHF 5 1.1/ LBHF LBHF 7 2.1/ LBHF LBHS 1 1/ LBHS 2 3/ LBHS LBHS 4 1.1/ LBHS 5 1.1/ LBHS LBHS 7 2.1/ LBHS Description: The LBH elbows have curvilinear body at 90 with two threaded entries and a cover, flat joint, fixed by screws. Materials: Body and cover: aluminium alloy. Screws: galvanized steel. Application: The LBH elbows are used to facilitate the insertion of not very flexible cables or of big sections and to vary the direction of ducts. On request: Other types of thread. B 2 Rev. 0 on 04.99
7 of protection: Class of temperature: Protection degree: Certificate: EEx d IIC T6 IP 65* INIEX 88B Junction and pulling boxes S. Draw. 1 Draw. 2 Entries ISO 7/1 n A B C D SB / SB / SB / SB SB / Draw. 1 SB SC / SC / SC / SC / SC SC / Draw. 2 SC SD / SD / SD / SD SD / Draw. 1 SD SL / SL / SL / SL / SL SL / Draw. 2 SL Description: The S. boxes are circular shaped and have screwed cover. Materials: Body and cover: aluminium alloy. Screws: stainless steel. Entries ISO 7/1 n A B C D SM / SM / SM / SM SM / Draw. 1 SM ST / ST / ST / ST / ST ST / Draw. 2 ST SW / SW / SW / SW SW / Draw. 1 SW SX / SX / SX / SX / SX SX / Draw. 2 SX Application: The S. boxes are used to pull and join conductors in lighting systems, motive power and instrumentation. On request: *Neoprene o ring (IP 65). Terminals. Rev. 0 on B 3
8 SF. Junction and pulling boxes with fixing flange of protection: Class of temperature: Protection degree: Certificate: EEx d IIC T6 IP 65* INIEX 88B Entries ISO 7/1 n A C D E SFC / SFC SFC / SFC SFL / SFL SFL / SFL SFT / SFT SFT / SFT SFX / SFX SFX / SFX Description: The SF. boxes are circular shaped and have screwed cover and backward fixing flange. Materials: Body and cover: aluminium alloy. Fixing flange: galvanized steel. Screws: stainless steel. Application: The SF. boxes are used to pull and joint conductors in lighting systems, motive power and instrumentation. On request: *Neoprene o ring (IP 65). Terminals. B 4 Rev. 0 on 04.99
9 of protection: Class of temperature: Protection degree: Certificate: EEx d IIC T6 IP 65* INIEX 88B Suspension boxes for lighting fixtures SSC Entries ISO 7/1 n A B C D E F G SSC / SSC Description: The SSC boxes are circular shaped and have screwed cover lateral fixing flange. Materials: Body and cover: aluminium alloy. Fixing flange: stainless steel. Screws: stainless steel. Application: The SSC boxes are used for fixing lighting fixtures on the ceiling. On request: *Neoprene o ring (IP 65). Terminals. Rev. 0 on B 5
10
11 Protection degree: IP 65 Waterproof pulling boxes CONDULETS 2 entries 2 entries 2 entries 2 entries 2 entries 3 entries 3 entries 4 entries Entries 1/2 C 17 LB 17 LU 17 LL 17 LR 17 T 17 TB 17 X 17 3/4 C 27 LB 27 LU 27 LL 27 LR 27 T 27 TB 27 X 27 1 C 37 LB 37 LU 37 LL 37 LR 37 T 37 TB 37 X /4 C 47 LB 47 LU 47 LL 47 LR 47 T 47 TB 47 X /2 C 57 LB 57 LU 57 LL 57 LR 57 T 57 TB 57 X 57 2 C 67 LB 67 LU 67 LL 67 LR 67 T 67 TB 67 X /2 C 77 LB 77 LU 77 LL 77 LR 77 T 77 TB 77 X 77 3 C 87 LB 87 LU 87 LL 87 LR 87 T 87 TB 87 X 87 4 C 107 LB 107 LU 107 LL 107 LR 107 T 107 TB 107 X 107 Entries D A A1 B B1 B2 C C1 E 1/ / / / / Description: The waterproof boxes called CONDULETS are rectangular shaped and their cover with gasket is fixed by two screws. Materials: Body and cover: aluminium alloy. Screws: galvanized steel. Gasket: rubber. Thread: UNI ISO 228. Application: The boxes CONDULETS are used for waterproof equipments to pull and join. On request: Other types of thread. Rev. 0 on B 7
12
Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series
Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes
More informationCONTROL STATIONS, CONTROL AND LIMIT SWITCHES
CONTROL STATIONS, CONTROL AND LIMIT SWITCHES C1 : EExd IIB PUSH BUTTON BOXES EFDC C2 : EExd IIB EMERGENCY PUSH BUTTON BOXES (MUSHROOM) EFD/EF C3 : EExd IIB EMERGENCY PUSH BUTTON BOXES (BREAKING GLASS)
More informationStainless steel product guide
Stainless steel product guide 2012 To be sure to be safe. INDEX Junction boxes EJBX series P. 4 Junction boxes CCAI series P. 6 Junction boxes S...S series P. 8 Junction boxes SF...S, SSC...S series P.
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More informationEJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...
EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)
More informationLB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationSTAINLESS STEEL CONDUIT SYSTEM WITH NPT THREADS
STAINLESS STEEL CONDUIT SYSTEM WITH NPT THREADS SILICONE GASKETS (FDA APPROVED) SMOOTH - EASY TO CLEAN (316) STAINLESS STEEL LID STAINLESS STEEL (316) BODY PATENTED 1 Stainless Steel NPT Conduit System
More informationFM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide
More informationFM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors
More informationFM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationSpec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch
More informationS and SF Series Cast Iron Inverted Bucket Steam Traps
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSafety Limit Switches
Safety Limit Switches with separate actuator Z02: Snap action 2NC Y+Y 3 Bent key 4 Flat key 5 Bent key 6 Flat key 7 Shock absorbing bent key 8 Shock absorbing flat key 9 Adjustable joint key Z11: Snap
More information6 Omnitrack 02_Omnit _15.indd 6 27/04/15 13:18
6 Omnitrack F Omnitrack - 3 circuits 16 7 POWERED TRACKS L2 L3 L1 N 1200/2000/3000/00 Housing: Three-phase track for 3 separate electrical circuits. Extruded aluminium rectangular section, containing an
More informationForm 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.
For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationSAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire
SAFR LED SERIES Hazardous Location LED Luminaire Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844
More informationForm 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationCondulet Conduit Bodies and Outlet Boxes Hazardous
Condulet Conduit Bodies and Outlet Boxes Hazardous 4F Description Page No. Application/Selection 48, 49 Lubricants HTL 59 STL 59 Conduit Bodies & Outlet Boxes Cylindrical EKC 57 90 Elbow LBH 58 LBY 58
More informationRosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries
Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering
More informationMHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT
MHD2/MHDO SERIES Marine Heavy Duty Outdoor Non-Metallic Fluorescent Non-metallic, glass reinforced polyester housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting
More informationINDEX. Chapter1 6. air master. Volume Control Dampers
Chapter1 6 INDEX 1 Volume control damper...:avcd...16.1 Standard sizes...16.2 Fixing details...16.2 How to order...16.2 Performance chart...16.3 2. Circular volume control damper....:avcd-c....16.4 Standard
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More informationMHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent
MHD2/MHDO SERIES Marine Heavy Duty Non-Metallic Fluorescent Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844 Hazardous Locations
More informationWaterproof Circular Connectors Conforming to European Safety Standards
Waterproof Circular Connectors Conforming to European Safety Standards CE05 Series Conforming Standard MIL-DTL-5015 Wa t e r p r o o f IP 67 OUTLINE The industrial machinery including the machine tools
More informationT38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationDuct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code
Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors
More informationBUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight
380 South Street 7596-763, TX Nacogdoches Phone: 936-569-79 Fax: 936-560-685 BUB00M -In Mog Cond Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationAccessories Cable glands
Accessories Cable glands 235 Technical data Cable glands Brass hexagon cable gland Brass sealing cable gland Material: Brass, nickel-plated Gasket: Soft rubber Protection type IP 54 Additional information:
More informationMHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations
MHDS SERIES Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 198A Marine
More informationRemote Sensor Kits. Installation Manual. Document No (Revision C)
Remote Sensor Kits Installation Manual Document No. 360-0127-01 (Revision C) Sensidyne, LP 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602 +1 727-539-0550
More informationCOMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications
Class I, Division per NEC 50.0(B)() Applications Larger body size facilitates pulling of large and heavy conductors. Specially designed raised cast covers provide additional wiring area. Mogul Unilets
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationBeacons/Strobes. 5 Joule Flashing Xenon Explosionproof. Certification ATEX GOST R & K, Chinese. ATEX Ex II 2G, EExd IIC T5/T6
SM87 HXB Voltage Lens Colour Ordering Code Ex II 2G 24V d.c. Red 813005 Ex II 2G 24V d.c. Amber 813006 Ex II 2G 240V a.c. Red 813007 Ex II 2G 240V a.c. Amber 813008 XB11 5 Joule Flashing Xenon 7 Standard
More informationAluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades. Allows connection of straight conduit runs, branch
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationBACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series
Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the
More informationNA2XSEKRY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95
More informationEWE. Ex de. Cooling fins
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More informationHOMA WELLHEAD FACILITY&PIPELINE (W027S)
DOC TITLE ELECTRICAL MATERIAL TAKE OFF PAGE NO. REV. 4 OF 10 00 Distribution Hermitically Sealed Transformer, 50 kva, 20/0.4 kv, ONAN, YZN5,+4*1% &-4*1% 1 TRANSFORMER TAP,With suitable Base and LV terminal
More informationSeismic Sensor Accessories SA, SV & ST 6000 Series
Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28
More informationUTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper
Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,
More informationTUNNEL LED LIGHTING. High power, low consumption public LED lighting
...Tunnel LED Lighting solutions... TUNNEL LED LIGHTING High power, low consumption public LED lighting Specially designed for tunnel and underground lighting applications, the Joliet tunnel lamp unit
More informationNA2XSEKY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5
More informationJunction box for EKL light
M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven
More informationMR - MEDIUM RATING A
88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationIt s time to get connected with
It s time to get connected with The essence of quality NEW See pag e6 PRATLEY products and P NUTS are distributed exclusively in the UK by: Cable Connectors Ltd Product Brochure Aluminium Alloy (Corrosion
More informationL I N K I N G T H E P R O C E S S W I T H T H E C O N T R O L R O O M CCOE
L I N K I N G T H E P R O C E S S W I T H T H E C O N T R O L R O O M VALVE CONTROLS CCOE LINE CARD ( IP65 WEATHER PROOF LIMIT SWITCH BOX ) The SOLDO IP65 limit switch box provides a compact design and
More informationAppleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.
ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range
More informationExplosion and flame-proof cast iron electric motors
Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting
More informationTubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22
Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation
More informationControl Panels, Distribution Panels and Components
11 Control Panels, Distribution Panels and Components EEx d Enclosures in Light Metal or stainless steel Flexible modular design for combining enclosures Can be used in Zone 1 and Zone 2 in Zone 21 and
More informationLocal Control Station
Local Control Station As per table given below Ex'd', IIC, IP-66, FLP/WP Local Control Station and Switch MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFRS/104/I/IIC-IEC MFRS/104/IIC-IEC A B C D
More informationMTD Silent Series MIXED FLOW IN-LINE DUCT FAN
MT Silent Series MIX LOW IN-LIN UT N Mixed low In-Line uct an MT Silent Series MT Silent 100/2~200/2 MT Silent 250~315 Low profile Mixed-flow fans with sound- absorbent insulation. xtreme ly quiet. General
More informationMagnaPro Hazardous Area Drop Lens Fluorescent
CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Type 3 UL 844 - Class I Div. 2 - Groups A, B, C, & D UL - Outdoor Marine
More informationRLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22
Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018
More informationLB - LIGHTING BUSWAY 25-40A
16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing
More informationOur policy is one of continued research and development. We therefore reserve the right
For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust
More informationMulberry Metal Products Seattle Stock Sheet
Weatherproof Lampholders (catalog page B23) 30001 Die Cast Lampholders Residential Grade Aluminum 36 39 lbs. 30002 Die Cast Lampholders Residential Grade Natural 36 39 lbs. 30003 Deluxe Lampholder Gray
More informationALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES
Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are
More informationActuated Valves. Product Information
Actuated Valves Product Information HQ4 & HQ6 HQ Electric Actuator for Albion Ball & Butterfly Valves Small, light and compact design High Output torque Alloy Gearing Multi Voltage Options Standard Specification
More informationSquare Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.
Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable
More informationEWE. Cooling fins. Ex de
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationMobrey MSM400 Ultrasonic sludge density measurement system
Technical specification sheet IP257 October 2008 Mobrey MSM400 Ultrasonic sludge density measurement system Level Features Measuring range up to 50% solids Simple keypad operation HMI menu based programming
More informationControl Stations CP.../EFDCN
CP.../EFDCN The CP EFDCN range of control stations are based on the features of our CP enclosure, which offers an Ex d IIC mode of protection with or without accessories (push buttons, selector switches,
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More informationExplosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS
Ex d Ring Enclosure Ex e Terminal Boxes Hollow Option Ambient Temperature Maximum Throughput Current Protection Mounting (increased range available) 20 rpm (higher on request) 770V ac 1166 Amps In any
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More information1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB57SA 1-1/2 Al LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More informationMaterial, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T37 1 T FM7 CND BD Appleton/Oz Gedney Catalog Number T37 Manufacturer Appleton/Oz Gedney Description FM7 Unilets Type
More informationSolutions Ex d IIB+H2, Aluminum and Stainless Steel
Features Assembly examples Enclosures manufactured from copper-free aluminum or AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 40 enclosure
More informationTRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Reduced-profile, single-circuit trac sections for surface or pendant mounting. Compatible with a full range of feed, connector
More informationN2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv
N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv Cu / XLPE / AWA / PVC (, XLPE Insuled, Aluminium Wire Armor, ed) 25 16.6 503 35 17.7 612 50 19.5 783 70 21.5 1,014 95 23.5 1,280
More informationSuspense System - Cable Kits
Suspense System - Cable Kits FLOOR-CEILING KIT provides the universal solution for display builders. Use either floor-ceiling application or as a shelving system inside cabinetry. 1.5mm Cable Kit Kit includes
More informationSmoke damper EKO-SRB1
Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation
More informationBFG range BFGC range BFN range
BFG range BFGC range BFN range LOW AND MEDIUM VOLTAGE FOR HAZARDOUS AREAS EEx d EEx de EEx na - Flameproof Motors - Flameproof Motors With Increased Safety Terminal Box - Non Sparking Motors 1. MARKING
More informationWaterproof Series Waterproof
Waterproof Series Waterproof Technical Data Panel connector Panel connector, cable connector and coupler connector circular housing Locking screw connection Protection IP 65 with flat-gasket for panel
More informationPART LIST P T O P T O S E R I E S S E R I E S
PART LIST P T O 1 0 0 0 S E R I E S P T O 2 0 0 0 S E R I E S Bezares U.S.A. PART LIST & TABLE 1 Nov. 2017 Bezares U.S.A. PART LIST & TABLE 2 Nov. 2017 PTO 1000 & 1010 Series SAE B 2/4 Bolt PART 1 4 Screw
More informationDescription Version Enclosure Supply Order No. Symbol SONO 3000 transmitter for compact and wall mounting IP67 (NEMA 4X/6)
Spare part SONO 3000 transmitter, available standard versions Description Version Enclosure Supply SONO 3000 transmitter for compact and wall mounting IP67 (NEMA 4X/6) Fibre glass reinforced polyamid 115
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationpressure gauges with electric contacts PBX100XA + KX.X [Built-In Type]
PBX00XA + KX.X [BuiltIn Type] They are used to control the electrical operation of compressors, pumps, presses, hydraulic and pneumatics equipment, chemical and petrochemical plant. The contacts open or
More informationJunction Boxes Hazardous and Non-Hazardous
Junction Boxes Hazardous and Non-Hazardous Description Page No. Application/Selection 112 Boxes Flush EGJ Series 19 WJBF Recessed Sidewalk Cover Series 116 Service Station EGJ Series 19 GUA Series 17 GUP
More informationMobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter
Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically
More informationJ-1. Explosion-Proof Junction Unilets. Features: Junction Boxes Outlet Boxes
Explosion-Proof Junction Unilets J-1 Features: Junction Boxes Outlet Boxes Compliance Data:, Groups B, C, D; Class I Zone 1 and 2, IIB + H 2 T6, Class III, Enclosure 3, weatherproof EEMAC Type 3R, 7BCD,
More information1SLC004001B0202. Enclosures and cable systems overview
1SLC004001B0202 Enclosures and cable systems overview Insulating enclosures and installation material IP40 flushmounting Estetica series IP40 flushmounting Europa series IP40 wallmounting Unibox series
More informationDimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,
Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully
More informationNIDEC-SHIMPO. Planetary Gearboxes - Flexwave
Near Zero backlash High efficiency ratings High reduction ratios in a compact footprint Exceptional repeatability and torsional stiffness Extremely light weight with superior torque density These characteristics
More informationCONDUIT BODIES CONDUIT BODIES. Phone:
i i Con it Bo ies allea le I on o i i I C con it cond ctors or p llin splicin Tapered threaded hu s - NPT Suita le or use in concrete Threaded LB Conduit Bodies MLB1 1/2 4-11/16 1-5/16 2-1/16 70 70.6 MLB2
More informationFM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationa Nexans company Catalogue 2012
a Nexans company Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationGENE RICH SPECIALTIES
All s Final - No Returns Allowed Attn: Plumbing Specialties Buyers Limited Time for Super Savings on Select Items: Faucets and Supplies Compression Tees and Couplings Dielectric Unions Red, Yellow and
More informationEDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories
More informationSquare Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.
Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors
More informationPROCESS INDUSTRY PNEUMATIC SOLUTIONS
PROCESS INDUSTRY PNEUMATIC SOLUTIONS Pneumatrol provide engineered pneumatic solutions for use within hazardous and non-hazardous area environments. For over 50 years Pneumatrol has developed the technical
More informationATEX CONNECTORS: PLUGS AND SOCKETS
: S AND S www.gruposiccis.com CONTENTS S AND S Page DXN1... 2 DXN3... 3 DXN6... 4 DX1... 5 DX3... 6 DX6... 7 DX9... 8 DX2... 9 PXN12C... 10 DXN25C... 11 DXN37C... 12 SPEX... 13 BOXES MXBS... 14 JUNCTION
More information