3 Price List Power Distribution Components Product Name Page No. Air Circuit Breaker - WiNmaster 9-0 ACB Order Form - WiNmaster Air Circuit Breaker - "AH" Series 2-9 ACB Order Form - "AH" Series 20 Power Capacitor 2 Maximum Retail Price Power Distribution Components Product Name Page No. New WiNbreak Moulded Case Circuit Breaker New WiNbreak Plug-in Moulded Case Circuit Breaker 29 WiNbreak Moulded Case Circuit Breaker 30-3 WiNbreak2 Moulded Case Circuit Breaker WiNbreak Moulded Case Circuit Breaker ACE 2 Moulded Case Circuit Breakers Switch Disconnector Fuse Unit Switch Disconnector 4 Moulded Switches with Plastic Enclosure 42 Changeover Switch Bypass, Side Handle Changeover & Re-wireable Switch 46 HRC Fuse and Fuse Base Holder Power Control Components Product Name Page No Motor Protection Circuit Breaker (MPCB) 50 Mini Control Relay, 3 P Power Contactor & Overload Relay robusta2 Contactor & Overload Relay robusta Control Relay 56 robusta Power Contactor, 3 Pole 56 robusta Hoisting Power Contactors, Telecom Power Contactor 57 robusta Power Contactor 4 Pole 58 robusta Capacitor Duty Contactors 3 Pole 59 robusta Thermal Overload Relays, Heavy Duty Overload Relays 60 robusta Accessories and Spares 6-63 D Range Control Relay, 3 Pole Contactor & Overload Relay & 4 Pole Contactor 64 D Range Accessories and Spares 65 4 Pole & 2 Pole Contactor & Overload Relay 66 Industrial Plugs & Sockets 67

4 Power Control Components Product Name Page No Push Button (Plastic Body/ Bezel Series) 69 Selectror Actuator (Plastic Body / Bezel Series) 70 Pilot Lamp (Plastic Body I Bezel Series) 70 Push Button (Metallic Body/ Bezel Series) 7 Selector Actuator (Metallic Body /Bezel Series) 72 Pilot Lamp (Metallic Body I Bezel Series), Integrated Dual Colour LED 73 Accessories for Push Button & Pilot Lamp (Metallic Body) Control Stations 76 Plastic/ Metallic Operating Head for Control Station Assembly 77 Anmol Single Phase DOL, Submersible Pump Starter, DOL Motor Starter Anmol Submersible Pump Starter, 3 Phase DOL & Star Delta, Anmol Motor Starter Spares Industrial Motor Starter: DOL, Star Delta, Reversing Starter Intelligent Auto Transformer & Star Delta Starter 85 Final Power Distribution Components Product Name Page No Miniature Circuit Breaker: B, C, D & DC Series Residual Current Circuit Breaker 96 Distribution Board, Plug & Socket (Metal Clad) 97-00

5

6

7

8

9 ACB WiNmaster WiNmaster Air Circuit Breaker Features : LSING Protection True RMS Sensing Thermal Memory Fault Indication LCD Display Current Measurement Voltage Measurement Zone Selectivity Communication through RS 485 Port Power Measurement Harmonics LT Air Circuit Breaker with Intelligent Release MicroPro 4. WiNmaster breakers fitted with standard accessories, tabulated below, are included in the Prices mentioned in the subsequent tables. Manual Fixed (MF) - Microprocessor Release - Auxiliary Switch 4NO+4NC - Main CTs for 3 phase only - Terminal Type-Horizontal # - Power Supply Module Electrical Fixed (EF) - Microprocessor Release - Auxiliary Switch 4NO+4NC - Main CTs for 3 phase only - AC/DC Charging Motor - Closing Coil - Shunt Trip - Micro Switches as required for electrical operation - Terminal Type - Horizontal# - Power Supply Module Manual Drawout (MDO) - Microprocessor Release - Auxiliary Switch 6NO+6NC - Main CTs for 3 phase only - Safety Shutter - 48 Way auxiliary isolating contacts - Terminal Type - Horizontal upto 600A & 2500A and vertical for 2000/3200/4000A - Power Supply Module Electrical Drawout (EDO) - Microprocessor Release - Auxiliary Switch 6NO+6NC - Main CTs for 3 phase only - Safety Shutter - 48 Way auxiliary isolating contacts - AC/DC Charging Motor - Closing Coil - Shunt Trip - Micro Switches as required for electrical operation - Terminal Type-Horizontal upto 600A & 2500A and vertical for 2000/3200/4000A - Power Supply Module Fixed 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF Fixed 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA WM06N3P*MP4.(S) kA WM06N4P*MP4.(S) kA WM08N3P*MP4.(S) kA WM08N4P*MP4.(S) kA WM0N3P*MP4.(S) kA WM0N4P*MP4.(S) kA WM2N3P*MP4.(S) kA WM2N4P*MP4.(S) kA WM6N3P*MP4.(S) kA WM6N4P*MP4.(S) kA WM20N3P*MP4.(S) kA WM20N4P*MP4.(S) kA WM06S3P*MP4.(S) kA WM06S4P*MP4.(S) kA WM08S3P*MP4.(S) POR POR kA WM08S4P*MP4.(S) POR POR kA WM0S3P*MP4.(S) kA WM0S4P*MP4.(S) kA WM2S3P*MP4.(S) kA WM2S4P*MP4.(S) kA WM6S3P*MP4.(S) kA WM6S4P*MP4.(S) kA WM20S3P*MP4.(S) kA WM20S4P*MP4.(S) kA WM25S3P*MP4.(S) kA WM25S4P*MP4.(S) kA WM30S3P*MP4.(S) kA WM30S4P*MP4.(S) kA WM40S3P*MP4.(S) kA WM40S4P*MP4.(S) Drawout 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA WM06N3P*MP4.(S) kA WM08N3P*MP4.(S) kA WM0N3P*MP4.(S) kA WM2N3P*MP4.(S) kA WM6N3P*MP4.(S) kA WM20N3P*MP4.(S) kA WM06S3P*MP4.(S) kA WM08S3P*MP4.(S) kA WM0S3P*MP4.(S) POR POR kA WM2S3P*MP4.(S) kA WM6S3P*MP4.(S) kA WM20S3P*MP4.(S) kA WM25S3P*MP4.(S) kA WM30S3P*MP4.(S) kA WM40S3P*MP4.(S) Drawout 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA WM06N4P*MP4.(S) kA WM08N4P*MP4.(S) kA WM0N4P*MP4.(S) kA WM2N4P*MP4.(S) kA WM6N4P*MP4.(S) kA WM20N4P*MP4.(S) kA WM06S4P*MP4.(S) kA WM08S4P*MP4.(S) kA WM0S4P*MP4.(S) POR POR kA WM2S4P*MP4.(S) kA WM6S4P*MP4.(S) kA WM20S4P*MP4.(S) kA WM25S4P*MP4.(S) kA WM30S4P*MP4.(S) kA WM40S4P*MP4.(S) For ACB communication through RS 485 Port, please refer item no. 55 on page 9. Notes : ) In TP ACB if Earth Fault facility is required, add price of Neutral CTs from item no. 2 on page 0. 2) If Under Voltage Release is required, add price of UVT Coil from item no. 3 on page 0. 3) While ordering an ACB, complete the catalogue reference by replacing '*' with ACB type: MF - Manual Fixed, EF-Electrical Fixed, MD-Manual Drawout, ED-Electrical Drawout 4) All configured ACBs are non stockable. For further details please contact nearest branch office. 5) ACBs with higher breaking capacities are also available on request. 6) ACB with other protection release are also available please refer item no. page 0 # ACB with Vertical terminal optional with adaptor are available on request. Other options of terminals are available on request.

10 ACB WiNmaster WiNmaster Air Circuit Breaker Main Accessories For WiNmaster Air Circuit Breakers (Please specify ACB rating & type while placing order). Micro Processor- ACB Protection Release Sl. No Description MicroProcessor Based Micropro 3. Release (LSIG, Thermal Memory, Fault Indication) MicroProcessor Based Micropro 4. Release (LSING, Thermal Memory, ZSI, Communication RS 485 Port, Current Metering) MicroProcessor Based Micropro 5. Release (LSING, Thermal Memory, ZSI, Communication RS 485 Port, Current Metering) WM-MicroPro 3. WM-MicroPro 4.-* WM-MicroPro 5.-* Unit Price POR 4. Shunt Trip and Closing Coil Sl. Description No. Sl. No. 4.3 Description Lifter with variable size Loader (for all sizes of ACBs) 4. Shunt Trip 630A-4000A WM-AVH-S-AB-** 4.2 Closing Coil 630A-4000A WM-AVH-C-AB-** **Please specify voltage while ordering Neutral CT LIFTER LIFTER-SPL Unit Price 2200 Unit Price Door Interlock DOOR-INT-AB MicroProcessor Based Micropro 6.Release (LSING, Earth Leakage Protection, Over and Under Protection for Voltage / Frequency, Voltage unbalance, ACB operation cycle counter, ACB contact indication wear) MicroProcessor Based Micropro 7.Release (all features as 6., harmonic measures and protection) WM-MicroPro 6.-* WM-MicroPro 7.-* * Code for ACB Rating A B C D E F G H I 400A 630A 800A 000A 250A 600A 2500A 3200A 4000A 2. Single Phase Polyester Resin Cast CTs - In TP ACB, one additional CT will be required if, Ground Fault Protection is selected. Sl. No. Description Neutral CT /0.2A WM-CT-04-N /0.2A WM-CT-06-N /0.2A WM-CT-08-N /0.2A WM-CT-0-N /0.2A WM-CT-2-N Unit Price /0.2A WM-CT-6-N /0.2A WM-CT-20-N /0.2A WM-CT-25-N /0.2A WM-CT-32-N /0.2A WM-CT-40-N Under Voltage Trip Device - consisting of UVT Coil & Control device fitted in the ACB Sl. No. 3. Description Compact UVT Coil Upto 630A-4000A Unit Price WM-AUH-V-AB-** 5260 Sl. No. Description Suitable for ACB frame size / rating 630A~4000A 4.5 OCR (Fault) Alarm Switch WM-ALA-AB 4.6 Trip Indication Switch (For manual tripping only) WM-TIS-AB Unit Price 4.7 'Spring Charged' Indication Switch WM-SCIS-AB Position Indication Switch WM-ALB-AB Mechanical Operation Counter WM-ASC-AB 4. Key Lock (One lock + One key) WM-AKI-AB Castle Key Lock WM-CKI-AB Key Interlock (Consisting of 3-Key Locks with 2 Keys (same No.) fitted on 3 ACBs) Key Interlock (Consisting of 2-Key Locks with Key (same No.) fitted on 2 ACBs) WM-AKI--AB 4000 WM-AKI-2-AB MAL Insertion Preventor WM-MIP-AB 550 **Code for Coils Voltage Description AC Control Voltage DC Control Voltage 0V 220~240V 45~440V 24V 48V 0V 220V UVT FA MA NA - - FD MD SHUNT FA MA NA BD ED FD MD Closing Coil FA MA NA BD ED FD MD

11 WiNmaster ACB Order Form CUSTOMER NAME ORDER NO. & DATE DELIVERY DATE END USER / PANEL BUILDER NAME & PHONE NO. RATING OF ACB REQUIRED 630 A 000 A 600 A 2500 A 4000 A 800 A 250 A 2000 A 3200 A QTY. (NOS.) NO. OF POLES 3 POLE 4 POLE AMBIENT TEMP C OPERATION MOUNTING FIXED MANUAL DRAWOUT ELECTRICAL 48 WAY AUX. ISOLATING CONTACT ASSLY. POSITION INDICATION SWITCH CLOSING COIL V AC / V DC SHUNT TRIP COIL V AC / V DC MOTOR 240V AC 220V DC 0V AC 0V DC WITHOUT RELEASES RELEASES MICROPROCESSOR RELEASE M.PRO 3. M.PRO 4. M.PRO 5. M.PRO 6. M.PRO 7. COMMUNICATION MODULE POWER SUPPLY MODULE BATTERY UNIT POWER SUPPLY & RELAY MODULE UNLESS & OTHERWISE SPECIFIED, ALL SETTINGS OF RELEASES WOULD BE SET AT MINIMUM VALUES. MAIN CT RATING A, NEUTRAL CT RATING A, SETTINGS : OVERLOAD A, SHORT CIRCUIT A, GROUND FAULT A INSTANTANEOUS A, NEUTRAL A, AUX. SW. 4 NO + 4 NC AUX. SW. 6 NO + 6 NC ACCESSORIES TRIP IND. SWITCH OCR ALARM SWITCH SPRING CHARGE IND. SWITCH POSITION IND. SWITCH CASTLE KEYLOCK KEY LOCK KEY INTERLOCK UVT V, DC AC 2 ACBs 3 ACBs CLOSE-OPEN CYCLE COUNTER DOOR INTERLOCK SPECIAL REQUIREMENT/ ACCESSORIES (IF ANY) Notes : () Please refer catalogue / Price-List, for further details of Micropro Release. (2) Neutral CT is required alongwith Microprocessor Release having Ground -Fault Protection. This has to be mounted on Earth / Neutral Busbar of Panel.

12 ACB "AH" Series Air Circuit Breaker "AH" Series (I) ACB with Intelligent Release MicroPro 4. Features: LSING Protection True RMS Sensing Zone Selectivity LCD Display Thermal Memory Fault Indication Current Measurement Communication through RS 485 Port "AH" Series breakers fitted with standard accessories, tabulated below, are included in the Prices mentioned in the subsequent tables. Manual Fixed (MF) - Microprocessor Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module Electrical Fixed (EF) - Microprocessor Release - Auxiliary Switch 5a 5b i.e. 5NO + 5NC - Main CTs for 3 Phase only - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module Manual Drawout (MDO) - Microprocessor Release - Auxiliary Switch 7a 7b i.e. 7NO + 7NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module Electrical Drawout (EDO) - Microprocessor Release - Auxiliary Switch 7a 7b i.e. 7 NO +7 NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module LT Air Circuit Breaker fitted with Intelligent Release MicroPro 4. Fixed 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH06DCSMP4.*(S) kA AH08DCSMP4.*(S) kA AHA-08N3P*MP4.(S) kA AHA-0N3P*MP4.(S) kA AH0DCSMP4.*(S) POR POR kA AH2DCSMP4.*(S) kA AH6DCSMP4.*(S) kA AHA-20N3P*MP4.(S) kA AH20DCSMP4.*(S) POR POR kA AH25DCSMP4.*(S) kA AHA-20S3P*MP4.(S) kA AH30DCSMP4.*(S) kA AH40DCSMP4.*(S) Fixed 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH06D4CSMP4.*(S) kA AH08D4CSMP4.*(S) kA AHA-08N4P*MP4.(S) kA AHA-0N4P*MP4.(S) kA AH0D4CSMP4.*(S) POR POR kA AH2D4CSMP4.*(S) kA AH6D4CSMP4.*(S) kA AHA-20N4P*MP4.(S) kA AH20D4CSMP4.*(S) POR POR kA AH25D4CSMP4.*(S) kA AHA-20S4P*MP4.(S) kA AH30D4CSMP4.*(S) kA AH40D4CSMP4.*(S) Drawout 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH06DCSMP4.*(S) kA AH08DCSMP4.*(S) kA AHA-08N3P*MP4.(S) kA AHA-0N3P*MP4.(S) kA AH0DCSMP4.*(S) POR POR kA AH2DCSMP4.*(S) kA AH6DCSMP4.*(S) kA AHA-20N3P*MP4.(S) kA AH20DCSMP4.*(S) POR POR kA AH25DCSMP4.*(S) kA AHA-20S3P*MP4.*(S) kA AHA-30S3P*MP4.*(S) kA AH30DCSMP4.*(S) POR POR kA AHA-40S3P*MP4.*(S) kA AH40DCSMP4.*(S) Drawout 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH06D4CSMP4.*(S) kA AH08D4CSMP4.*(S) kA AHA-08N4P*MP4. (S) kA AHA-0N4P*MP4. (S) kA AH0D4CSMP4.*(S) POR POR kA AH2D4CSMP4.*(S) kA AH6D4CSMP4.*(S) kA AHA-20N4P*MP4. (S) kA AH20D4CSMP4.*(S) POR POR kA AH25D4CSMP4.*(S) kA AHA-20S4P*MP4.*(S) kA AHA-30S4P*MP4.*(S) kA AH30D4CSMP4.*(S) POR POR kA AHA-40S4P*MP4.*(S) kA AH40D4CSMP4.*(S For ACB communication through RS 485 Port, please refer item no. 55 on page 9. Notes : ) In TP ACB if Earth Fault facility is required, add price of Neutral CTs from item no. 4. on page 6. 2) If Under Voltage Release is required, add price of UVT Coil from item no. 7 on page 7. 3) Prices of ACBs rating 5000 & 6300A available on request. 4) While ordering an ACB, complete the catalogue reference by replacing '*' with ACB type: MF-Manual Fixed, EF-Electrical Fixed, MD- Manual Drawout, ED-Electrical Drawout 5) All configured ACBs are non stockable. For further details please contact nearest branch office. 6) ACBs with higher breaking capacities are also available on request. 7) ACBs with vertical terminal are available in ratings 6D~6D/08N-20S(AHA) in drawout type only. ACB with Vertical terminal optional with adaptor are available on request.

13 Air Circuit Breaker "AH" Series (II) ACB with Intelligent Release MicroPro 3. Features: LSIG Protection True RMS Sensing Fault Indication "AH" Series breakers fitted with standard accessories, tabulated below, are included in the Prices mentioned in the subsequent tables. Manual Fixed (MF) - Microprocessor Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module Electrical Fixed (EF) - Microprocessor Release - Auxiliary Switch 5a 5b i.e. 5NO + 5NC - Main CTs for 3 Phase only - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module Manual Drawout (MDO) - Microprocessor Release - Auxiliary Switch 7a 7b i.e. 7NO + 7NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module Electrical Drawout (EDO) - Microprocessor Release - Auxiliary Switch 7a 7b i.e. 7 NO +7 NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Power Supply Module LT Air Circuit Breaker fitted with Intelligent Release MicroPro 3. Fixed 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH-06DCSMP3.*(S) kA AH-08DCSMP3.*(S) kA AHA-08N3P*MP3.(S) kA AHA-0N3P*MP3.(S) kA AH-0DCSMP3.*(S) POR POR kA AH-2DCSMP3.*(S) kA AH-6DCSMP3.*(S) kA AHA-20N3P*MP3.(S) kA AH-20DCSMP3.*(S) POR POR kA AH-25DCSMP3.*(S) kA AHA-20S3P*MP3.(S) kA AH-30DCSMP3.*(S) kA AH-40DCSMP3.*(S) Drawout 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH-06DCSMP3.*(S) kA AH-08DCSMP3.*(S) kA AHA-08N3P*MP3.(S) kA AHA-0N3P*MP3.(S) kA AH-0DCSMP3.*(S) POR POR kA AH-2DCSMP3.*(S) kA AH-6DCSMP3.*(S) kA AHA-20N3P*MP3.(S) kA AH20DCSMP3.*(S) POR POR kA AH25DCSMP3.*(S) kA AHA-20S3P*MP3.*(S) kA AHA-30S3P*MP3.*(S) kA AH30DCSMP3.*(S) POR POR kA AHA-40S3P*MP3.*(S) kA AH40DCSMP3.*(S) Fixed 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH06D4CSMP3.*(S) kA AH08D4CSMP3.*(S) kA AHA-08N4P*MP3.(S) kA AHA-0N4P*MP3.(S) kA AH0D4CSMP3.*(S) POR POR kA AH2D4CSMP3.*(S) kA AH6D4CSMP3.*(S) kA AHA-20N4P*MP3.(S) kA AH20D4CSMP3.*(S) POR POR kA AH25D4CSMP3.*(S) kA AHA-20S4P*MP3.(S) kA AH30D4CSMP3.*(S) kA AH40D4CSMP3.*(S) Drawout 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH06D4CSMP3.*(S) kA AH08D4CSMP3.*(S) kA AHA-08N4P*MP3. (S) kA AHA-0N4P*MP3. (S) kA AH0D4CSMP3.*(S) POR POR kA AH2D4CSMP3.*(S) kA AH6D4CSMP3.*(S) kA AHA-20N4P*MP3. (S) kA AH20D4CSMP3.*(S) POR POR kA AH25D4CSMP3.*(S) kA AHA-20S4P*MP3.*(S) kA AHA-30S4P*MP3.*(S) kA AH30D4CSMP3.*(S) POR POR kA AHA-40S4P*MP3.*(S) kA AH40D4CSMP3.*(S) Notes : ) In TP ACB if Earth Fault facility is required, add price of Neutral CTs from item no. 4. on page 6. 2) If Under Voltage Release is required, add price of UVT Coil from item no. 7 on page 7. 3) Prices of ACBs rating 5000 & 6300A available on request. 4) While ordering an ACB, complete the catalogue reference by replacing '*' with ACB type: MF-Manual Fixed, EF-Electrical Fixed, MD- Manual Drawout, ED-Electrical Drawout 5) All configured ACBs are non stockable. For further details please contact nearest branch office. 6) ACBs with higher breaking capacities are also available on request. 7) ACBs with vertical terminal are available in ratings 6D~6D/08N-20S(AHA) in drawout type only. ACB with Vertical terminal optional with adaptor are available on request.

14 ACB "AH" Series Air Circuit Breaker "AH" Series (III) ACB with Microprocessor Release µit-00 (Discontinued) LSIG Protection True RMS Sensing Fault Indication "AH" Series breakers fitted with standard accessories, tabulated below, are included in the Prices mentioned in the subsequent tables. Manual Fixed (MF) Electrical Fixed (EF) Manual Drawout (MDO) Electrical Drawout (EDO) - Microprocessor Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Microprocessor Release - Auxiliary Switch 5a 5b i.e. 5NO + 5NC - Main CTs for 3 Phase only - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Microprocessor Release - Auxiliary Switch 7a 7b i.e. 7NO + 7NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Microprocessor Release - Auxiliary Switch 7a 7b i.e. 7 NO +7 NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A LT Air Circuit Breaker fitted with Microprocessor Release type µit-00 / µit-g (Includes Rectifier Unit 220V AC / 24V DC type ARO - B in standard supply) Fixed 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH-6D-CS-MP-* kA AH-8D-CS-MP-* kA AHA-08N3P*MP kA AHA-0N3P*MP kA AH-0D-CS-MP-* POR POR kA AH-2D-CS-MP-* kA AH-6D-CS-MP-* kA AHA-20N3P*MP kA AH-20D-CS-MP-* POR POR kA AH-25D-CS-MP-* kA AHA-20S3P*MP kA AH-30D-CS-MP-* kA AH-40D-CS-MP-* Fixed 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH-6D-4CS-MP- * kA AH-8D-4CS-MP- * kA AHA-08N4P*MP kA AHA-0N4P*MP kA AH-0D-4CS-MP- * POR POR kA AH-2D-4CS-MP-* kA AH-6D-4CS-MP-* kA AHA-20N4P*MP kA AH-20D-4CS-MP-* POR POR kA AH-25D4CS-MP-* kA AHA-20S4CS*MP kA AH-30D-4CS-MP-* kA AH-40D-4CS-MP- * Drawout 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH-6D-CS-MP- * kA AH-8D-CS-MP- * kA AHA-08N3P*MP kA AHA-0N3P*MP kA AH-0D-CS-MP- * POR POR kA AH-2D-CS-MP- * kA AH-6D-CS-MP- * kA AHA-20N3P*MP kA AH-20D-CS-MP- * POR POR kA AH-25D-CS-MP- * kA AHA-20S3P*MP kA AHA-30S3P*MP kA AH-30D-CS-MP- * POR POR kA AHA-40S3P*MP kA AH-40D-CS-MP Drawout 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH-6D-4CS-MP- * kA AH-8D-4CS-MP- * kA AHA-08N4P*MP kA AHA-0N4P*MP kA AH-0D-4CS-MP- * POR POR kA AH-2D-4CS-MP- * kA AH-6D-4CS-MP- * kA AHA-20N4P*MP kA AH-20D-4CS-MP- * POR POR kA AH-25D-4CS-MP- * kA AHA-20S4P*MP kA AHA-30S4P*MP kA AH-30D-4CS-MP- * POR POR kA AHA-40S4P*MP kA AH-40D-4CS-MP Notes : ) In TP ACB if Earth Fault facility is required, add price of Neutral CTs from item no. 4.2 on page 6 2) If Under Voltage Release is required, add price of UVT Coil from item no. 7 on page 7 3) Prices of ACBs rating 5000 & 6300A available on request. 4) While ordering an ACB, the complete catalogue reference by replacing '*' with ACB type: MF-Manual Fixed, EF-Electrical Fixed, MD-Manual Drawout, ED-Electrical Drawout 5) All configured ACBs are non stockable. For further details please contact nearest branch office. 6) ACBs with higher breaking capacities are also available on request. 7) ACBs with vertical terminal are available in ratings 6D~6D/08N-20S(AHA) in drawout type only. ACB with Vertical terminal optional with adaptor are available on request.

15 ACB "AH" Series Air Circuit Breaker "AH" Series (IV) ACB with Thermal Magnetic Release "AH" Series breakers fitted with standard accessories, tabulated below, are included in the Prices mentioned in the subsequent tables. Manual Fixed (MF) Electrical Fixed (EF) Manual Drawout (MDO) Electrical Drawout (EDO) - Thermal Magnetic Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - Shunt Trip - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Thermal Magnetic Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for electrical operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Thermal Magnetic Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - Shunt Trip - Safety Shutter - 24 way Auxiliary Isolating contacts - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A - Thermal Magnetic Release - Auxiliary Switch 5a 5b i.e 5NO+5NC - Main CTs for 3 Phase only - Safety Shutter - 36 way Auxiliary Isolating contacts - AC/DC Charging Motor - Closing Coil - Shunt Trip - Anti-pumping Relay - Micro Switches as required for operation - Terminal Type - Horizontal upto 2500A & Vertical for 3200A/4000A LT Air Circuit Breaker fitted with Thermal Magnetic Release and Standard Accessories, as applicable. Fixed 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH-6D-CS-TM- * kA AH-8D-CS-TM- * kA AHA-08N3P*TM kA AHA-0N3P*TM kA AH-0D-CS-TM- * POR POR kA AH-2D-CS-TM- * kA AH-6D-CS-TM- * kA AHA-20N3P*TM kA AH-20D-CS-TM- * POR POR kA AH-25D-CS-TM- * kA AHA-20S3P*TM kA AH-30D-CS-TM- * kA AH-40D-CS-TM- * Fixed 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MF *EF kA AH-6D-4CS-TM- * kA AH-8D-4CS-TM- * kA AHA-08N4P*TM kA AHA-0N4P*TM kA AH-0D-4CS-TM- * POR POR kA AH-2D-4CS-TM- * kA AH-6D-4CS-TM- * kA AHA-20N4P*TM kA AH-20D-4CS-TM- * POR POR kA AH-25D-4CS-TM- * kA AHA-20S4P*TM kA AH-30D-4CS-TM- * kA AH-40D-4CS-TM- * Drawout 3 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH-6D-CS-TM- * kA AH-8D-CS-TM- * kA AHA-08N3P*TM kA AHA-0N3P*TM kA AH-0D-CS-TM- * POR POR kA AH-2D-CS-TM- * kA AH-6D-CS-TM- * kA AHA-20N3P*TM kA AH-20D-CS-TM- * POR POR kA AH-25D-CS-TM- * kA AHA-20S3P*TM kA AHA-30S3P*TM kA AH-30D-CS-TM- * POR POR kA AHA-40S3P*TM kA AH-40D-CS-TM- * Drawout 4 Pole Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price * MDO *EDO kA AH-6D-4CS-TM- * kA AH-8D-4CS-TM- * kA AHA-08N4P*TM kA AHA-0N4P*TM kA AH-0D-4CS-TM- * POR POR kA AH-2D-4CS-TM- * kA AH-6D-4CS-TM- * kA AHA-20N4P*TM kA AH-20D-4CS-TM- * POR POR kA AH-25D-4CS-TM- * kA AHA-20S4P*TM kA AHA-30S4P*TM kA AH-30D-4CS-TM- * POR POR kA AHA-40S4P*TM kA AH-40D-4CS-TM- * Notes : ) While ordering an ACB without Over Current Release, Shunt trip & Main CTs, please deduct 4500 for A; 6000 for 2000A; 7000 for A & 8000 for 4000A from the prices listed above. Shunt trip will be standard in electrical ACB without release as well. 2) In TP ACB if Earth Fault facility is required, add prices of Earth Fault Relay from item no. 2 on page 6 3) If Under Voltage Release is required, add price of UVT Coil from item no. 7 on page 7 4) Prices of ACBs rating 5000 & 6300A available on request. 5) While ordering an ACB, the complete catalogue reference by replacing '*' with ACB type: MF-Manual Fixed, EF-Electrical Fixed, MD-Manual Drawout, ED- Electrical Drawout 6) All configured ACBs are non stockable. For further details please contact nearest branch office. 7) ACBs with higher breaking capacities are also available on request. 8) ACBs with vertical terminal are available in ratings 6D~6D/08N-20S(AHA) in drawout type only. ACB with Vertical terminal optional with adaptor are available on request.

16 ACB "AH" Series Air Circuit Breaker "AH" Series "AH" Series breakers fitted with standard accessories, tabulated below, are included in the Prices mentioned in the subsequent tables. - Auxiliary Switch NO* - Main CTs for 3 Phase only - Shunt Trip for thermal magnetic *Auxiliary Switch with other combination is also available. See item No. 6 Manual Fixed, 3 Pole with Intelligent Release MicroPro 3. Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price *MF AH-6B-CS-MP3.- * AH-8B-CS-MP3.- * kA AH-0B-CS-MP3.- * AH-2B-CS-MP3.- * AH-6B-CS-MP3.- * Manual Fixed, 3 Pole with Thermal Magnetic Release Rating (Amps) Breaking Capacity Icu=Ics=Icw (sec) Unit Price *MF 630 AH-6B-CS-TM- * AH-8B-CS-TM- * kA AH-0B-CS-TM- * AH-2B-CS-TM- * AH-6B-CS-TM- * Main Accessories For D-type Air Circuit Breakers (Please specify ACB rating & type while placing order). ACB Protection Release (Micro Processor / Thermal) Sl. No.. Description MicroProcessor Based Micropro 3. Release (LSIG, Thermal Memory, Fault Indication) Unit Price AH-MICROPRO MicroProcessor Based Micropro 4..2 Release (LSING, Thermal Memory, ZSI, Communication RS 485 Port, AH-MICROPRO-4.-* Current Metering) MicroProcessor Based Micropro 5..3 Release (LSING, Thermal Memory, ZSI, Communication RS 485 Port, Current Metering) AH-MICROPRO-5.-* Thermal magnetic release CS-TOMCR 4500 *Code for ACB Rating A B C D E F G H I J K L M 00A 200A 250A 300A 400A 630A 800A 000A 250A 600A 2500A 3200A 4000A 2. Earth Fault Relay with NCT (Thermal Magnetic Release) Sl. No. Description Unit Price 2. For 6D-6D/08N-20S(AHA) EFR For 20D-25D/30S(AHA) EFR For 30D/40S(AHA) EFR For 40D EFR FRP Laminated Safety Shutter Assembly Sl. Description Unit Price No. 3. For 6D-6D/08N-20S(AHA) 3 Pole ASH- 790 For 6D-6D/08N-20S(AHA) 4 Pole ASH- (4P) For 20D-25D/30S(AHA) 3 Pole ASH For 20D-25D/30S(AHA) 4 Pole ASH-2 (4P) For 30D/40S(AHA) 3 Pole ASH For 30D/40S(AHA) 4 Pole ASH-3 (4P) For 40D 3 Pole ASH For 40D 4 Pole ASH-4 (4P) Single Phase Polyester Resin Cast CTs for D Series ACB for MicroPro 3., 4. & 5. Release - CT per pole is required. In TP ACB, one additional CT will be required if, Ground Fault Protection is selected. Sl. No. 5. Auxiliary Isolating Contact Assembly (set of one contact block on ACB side & two blocks on cradle side) Sl. No way 24 way 36 way Type Description Description 6D-6D/08N-20S(AHA), 3P 6D-6D/08N-20S(AHA), 4P 20D-25D/30S(AHA), 3P 20D-25D/30S(AHA), 4P 30D-40D/40S(AHA), 3P 30D-40D/40S(AHA), 4P 6D-6D/08N-20S(AHA), 3P 6D-6D/08N-20S(AHA), 4P 20D-25D/30S(AHA), 3P 20D-25D/30S(AHA), 4P 30D-40D/40S(AHA), 3P 30D-40D/40S(AHA), 4P 6D-6D/08N-20S(AHA), 3P 6D-6D/08N-20S(AHA), 4P 20D-25D/30S(AHA), 3P 20D-25D/30S(AHA), 4P 30D-40D/40S(AHA), 3P 30D-40D/40S(AHA), 4P Phase CT Neutral CT /0.2A WMCT /0.2A WMCT-02 ATB /0.2A WMCT /0.2A WMCT-034 ATB /0.2A WMCT-044 ATB D 630/0.2A WMCT-064 ATBWM D/08N(AHA) 800/0.2A WMCT-084 ATBWM D/0N(AHA) 000/0.2A WMCT-04 ATBWM D 250/0.2A WMCT-24 ATBWM D 600/0.2A WMCT-64 ATBWM N/20S(AHA) 2000/0.2A AHA-DO-WM-CT-20 ATBWM D 2000/0.2A ATBWM-220 ATBWM D 2500/0.2A ATBWM-225 ATBWM S(AHA) 3200/0.2A AHA-WM-CT-30 ATBWM D 3200/0.2A ATBWM-332 ATBWM S(AHA) 4000/0.2A AHA-WM-CT-40 ATBWM D 4000/0.2A ATBWM-440 ATBWM-440 AIH-2- AIH-2-(4P) AIH-2-2 AIH-2-2(4P) AIH-2-3 AIH-2-3(4P) CS-AIH-24- CS-AIH-24-(4P) CS-AIH-24-2 CS-AIH-24-2(4P) CS-AIH-24-3 CS-AIH-24-3(4P) CS-AIH-36- CS-AIH-36-4P) CS-AIH-36-2 CS-AIH-36-2 (4P) CS-AIH-36-3 CS-AIH-36-3 (4P) Unit Price Single Phase Polyester Resin Cast CTs for D Series ACB for Thermal release- CT per pole is required. In TP ACB, one additional CT will be required if, Ground Fault Protection is selected. Sl. No. Type Description Phase CT Neutral CT D 250/5A ATB-024 ATB D 400/5A ATB-044 ATB D 630/5A ATB-064 ATB D/08N(AHA) 800/5A ATB-084 ATB-080 Unit Price D/0N(AHA) 000/5A ATB-04 ATB D 250/5A ATB-34 ATB D 600/5A ATB-64 ATB N/20S(AHA) 2000/5A ATB-DO-CT-20 ATB D 2000/5A ATB-220 ATB D 2500/5A ATB-225 ATB S(AHA) 3200/5A AHA-CT-30 ATB D 3200/5A ATB-332 ATB S(AHA) 4000/5A AHA-CT-40 ATB D 4000/5A ATB-440 ATB Unit Price

17 Accessories - ACB Main Accessories For D-type Air Circuit Breakers (Please specify ACB rating & type while placing orders) 6. Auxiliary Switch Sl. No Description 5 way 6D-6D/08N-20S(AHA) (2NO+3NC) 20D-40D/30S-40S(AHA) 5 way 6D-6D/08N-20S(AHA) (3NO+2NC) 20D-40D/30S-40S(AHA) 0 way 6D-6D/08N-20S(AHA) (5NO+5NC) 20D-40D/30S-40S(AHA) 4 way 6D-6D/08N-20S(AHA) (7NO+7NC) 20D-40D/30S-40S(AHA) AXH-2A3B- AXH-2A3B-2 AXH-3A2B- AXH-3A2B-2 CS-AXH-5A5B- CS-AXH-5A5B-2 CS-AXH-7A7B- CS-AXH-7A7B-2 Unit Price 7. Under Voltage Trip Device (D Series ACB) consisting of UVT Coil & Control device fitted in the ACB Sl. No. Description 7. Compact UVT Coil6D-6D/08N-20S(AHA) CS-AUH-V-A-** D-40D/30S-40S(AHA) CS-AUH-V-B-** Unit Price 3680 Sl. No For Air Circuit Breaker Lifter with variable size Loader (for all sizes of ACBs) Door Interlock 6D-6D/08N-20S (AHA) Door Interlock (20D-40D)/ 30S-40S (AHA) Vertical Connection Copper Adapter (6D~8D) & 08N (AHA) (2 per pole required) Vertical Connection Copper Adapter (0D~2D) & 0N (AHA) (2 per pole required) LIFTER-SPL LIFTER DOOR-INT- DOOR-INT-2 Unit Price CUADPTR-VC(6D~8D) 4000 CUADPTR-VC(0 D~2D) Shunt Trip and Closing Coil Sl. Description No. Shunt Trip 6D-6D/08N-20S(AHA) 8. 20D-40D/30S-40S(AHA) Closing Coil 6D-6D/08N-20S(AHA) D-40D/30S-40S(AHA) CS-AVH-S--** CS-AVH-S-2-** CS-AVH-C--** CS-AVH-C-2-** Unit Price Vertical Connection Copper Adapter 6D & (20N-20S)AHA (2 per pole required) Vertical Connection Copper Adapter (20D~25D) (2 per pole required) CUADPTR-VC(6D) 5370 CUADPTR-VC(20 D~25D) 0840 **Please specify voltage while ordering **Code for Coils Voltage AC Control Voltage DC Control Voltage Description 0V 220~240V 45~440V 24V 48V 0V 220V UVT FA MA NA - - FD MD SHUNT FA MA NA BD ED FD MD Closing Coil FA MA NA BD ED FD MD Sl. No. Description 6D-6D/ 08N-20S(AHA) Suitable for ACB frame size / rating Unit Price 20D-40D/ 30S-40S(AHA) ALA-2 Unit Price 9 OCR (Fault) Alarm Switch (for ACB with MicroProcessor release only) ALA Trip Indication Switch (For manual and Fault tripping in ACB with TM release only) TIS - TIS 'Spring Charged' Indication Switch SCIS-M 790 SCIS-M Position Indication Switch ALB-4P- 950 ALB-IP Mechanical operation counter ASC- 80 ASC Key Lock (One lock + One key) AK-D 370 AKI-2D Castle Key Lock CKI CKI Key Interlock (Consisting of 3-Key Locks with 2 Keys (same No.) fitted on 3 ACBs) AKI AKI Key Interlock (Consisting of 2-Key Locks with Key (same No.) fitted on 2 ACBs) AKI AKI Short Circuit Contact for Shunting Auxiliary Isolating Contacts when ACB withdrawn SCC 330 scc 330 Rectifier Unit 240V AC / 24V DC, used for LED Indication or for function checking of 9 CS-ARO-BMA CS-ARO-BMA Microprocessor Release (Can Control Upto 5 no. of ACBs) Rectifier Unit 45V AC / 24V DC, used for LED Indication or for function checking of 20 CS-ARO-BNA CS-ARO-BNA Microprocessor Release (Can Control Upto 5 no. of ACBs) 2 Mal Insertion Preventor MIP6D-6D 480 MIP20-25D 480 Sl. No. Description Suitable for ACB frame size / rating 6D-6D/ 08N-20S(AHA) Unit Price 20C-25C Unit Price 2 Making Current Release / Instantaneous Trip CS-MCR CS-MCR Mechanical Interlock (Fixed Vertical) mil-6d-vf mil-20d-vf Mechanical Interlock (Fixed Horizontal) mil-6d-hf mil-20d-hf Mechanical Interlock (D/o Vertical) MIL-6d-VDO mil-20d-vdo Mechanical Interlock (D/o Horizontal) MIL-6D-HDO mil-20d-hdo 000 S. No. 22, 23, 24 & 25 will be supplied only factory fitted. These can not be fitted at site thus always order with ACB only.

18 Spares - ACB Spares For D-type Air Circuit Breakers (Please specify ACB rating & type while placing order for spares) 33. Drawout Mould Base (Cradle Side) For ACB Rating Qty. Required Per Pole* 6D-6D/08N-20S(AHA) DRMOULD-20S 2 20D DRMOULD-20D 2 Unit Price D/30S(AHA) DRMOULD-25D D/40S(AHA) DRMOULD-30D D DRMOULD-40D Arcing Contacts (Set of no. fixed & no. moving) For ACB Rating 35. Main Isolating Contacts (Jaw Contacts) For ACB Rating Qty. Required Per Pole* Qty. Required Per Pole* 6D-8D MIC-08D 2 08N(AHA)/0N(AHA) MIC-08D(50k) 2 Unit Price D/0N MIC-0D D MIC-2D 2 6D MIC-6D 2 20N(AHA)-F MIC-20N 2 20N(AHA)-DO /20S(AHA) MIC-20S 2 Unit Price 6D-8D/08N(AHA)/0N(AHA) ARCCONT-08D M / F D/0N ARCCONT-0D M / F 2D ARCCONT-2D M / F 400 6D ARCCONT-6D M / F N(AHA)-F ARCCONT-20N M / F 20N(AHA)-DO /20S(AHA) ARCCONT-20S M / F 20D ARCCONT-20D M / F D/30S(AHA) ARCCONT-25D M / F D/40S(AHA) ARCCONT-30D M / F D ARCCONT-40D M / F 2360 Note: *M - Moving, F - Fixed D MIC-20D D/30S(AHA) MIC-25D D/40S(AHA) MIC-30D D MIC-40D Moving Arcing Contact Main Moving Contact Assembly Lower Terminal Assembly Fixed Arcing Contact Main Fixed Contact (Upper Terminals) Main Isolating Contacts (Jaw Contacts) Drawout Mould Base Circuit (Drawout) Terminals ) Items for Drawout ACB. 2) Horizontal arrangement (as shown) upto 2500A & vertical for higher rating. 36. Main Fixed Contacts (Upper Terminals) For ACB Rating Qty. Required Per Pole* Unit Price 6D-8D FIXCONT-06D-08D N-0N(AHA) FIXCONT-08N D-2D FIXCONT-0D-2D D FIXCONT-6D N(AHA)-F FIXCONT-20N 20N(AHA)-DO /20S(AHA) FIXCONT-20S 20D FIXCONT-20D D/30S(AHA) FIXCONT-25D D/40S(AHA) FIXCONT-30D D FIXCONT-40D Lower Terminals with fitting plates For ACB Rating Qty. Required Per Pole* Unit Price 6D-8D/08N-0N(AHA) LWR-TRNL-8B-8D D-2D LWR-TRNL-2B-2D D LWR-TRNL-6B-6D N(AHA)-F LWR-TRNL-20N 20N(AHA)-DO /20S(AHA) LWR-TRNL-20S 20D LWR-TRNL-20C-20D D/30S(AHA) LWR-TRNL-25C-25D D/40S(AHA) LWR-TRNL-30C-30D D LWR-TRNL-40C-40D Circuit Terminals / Drawout Terminals For ACB Rating Qty. Required Per Pole* Unit Price 6D-8D/08N-0N(AHA) CKTTML-08N D-2D CKTTML-2D D CKTTML-6D 2 20N(AHA)-DO /20S(AHA) CKTTML-20S 2 20D CKTTML-20D D/30S(AHA) CKTTML-25D D/40S(AHA) CKTTML-30D D CKTTML-40D Main Moving Contacts Assembly For ACB Rating Qty. Required Per Pole* Unit Price 6D-8D MOVMAIN-06D-08D N-0N(AHA) MOVMAIN-08N D-20D MOVMAIN-0D-2D D MOVMAIN-6D N(AHA)-F MOVMAIN-20N N(AHA)-DO /20S(AHA) MOVMAIN-20S D MOVMAIN-20D D/30S(AHA) MOVMAIN-25D D/40S(AHA) MOVMAIN-30D D MOVMAIN-40D 3530 F-Fixed Type, DO-Drawout Type "*" To arrive at total quantity per ACB, multiply by 3 or 4 depending upon number of poles in the ACB.

19 Spares - ACB Spares For D-Type Air Circuit Breakers (Please specify ACB rating & type while placing order for spares) 40. Complete Pole Unit (Common for 3 & 4 Pole ACBs) Sl. No. For Air Circuit Breaker Unit Price 40. Single Pole unit for 6D CONDUNIT-6D Single Pole unit for 8D CONDUNIT-8D Single Pole unit for 08N-0N(AHA) CONDUNIT-8N Single Pole unit for 0D CONDUNIT-0D Single Pole unit for 2D CONDUNIT-2D Single Pole unit for 6D CONDUNIT-6D Single Pole unit for 20N(AHA)-F CONDUNIT-20N Single Pole unit for 20N(AHA)-DO /20S(AHA) CONDUNIT-20S Single Pole Unit for 20D CONDUNIT-20D Single Pole Unit for 25D/30S(AHA) CONDUNIT-25D Single Pole Unit for 30D/40S(AHA) CONDUNIT-30D Single Pole Unit for 40D CONDUNIT-40D 6560 F-Fixed Type, DO-Drawout Type Other Spares Sl. Description No. New Style Micro Switch for 43 Motor cut off 6D-40D/08N-40S(AHA) Anti Pumping Relay 6D-6D/08N-20S(AHA), 3P 6D-6D/08N-20S(AHA), 4P 44 20D-25D/30S(AHA), 3P 20D-25D/30S(AHA), 4P 30D-40D/40S(AHA), 3P 30D-40D/40S(AHA), 4P Manual Charging Handle 45 6D-6D/08N-20S(AHA) Manual Charging Handle 46 20D-40D/30S-40S(AHA) Drawout Handle 47 6D-6D/08N-20S(AHA) Drawout Handle 48 20D-40D/30S-40S(AHA) Magnet Hold Trigger 49 6D-6D/08N-20S(AHA), 3P 6D-6D/08N-20S(AHA), 4P Magnet Hold Trigger 20D-25D/30S(AHA), 3P 50 Magnet Hold Trigger 20D-25D/30S(AHA), 4P Magnet Hold Trigger 30D-40D/40S(AHA), 3P Magnet Hold Trigger 30D-40D/40S(AHA), 4P D/O Telescopic Rail (L) 6D-6D/08N-20S(AHA) 20D-25D/30S(AHA) 30D-40D/40S(AHA) D/O Telescopic Rail (R) 6D-6D/08N-20S(AHA) 20D-25D/30S(AHA) 30D-40D/40S(AHA) Unit Price MICROSW * 890 CS-ANTPUMPRLY-** 3050 CS-ANTPUMPRLY-2 ** 3570 CS-ANTPUMPRLY-3** 400 MCLHND-6D-6D 2420 MCLHND-20D-40D 2630 DRHND-6D-6D 2000 DRHND-20D-40D 2420 MHT-6D-3P MHT-6D-4P MHT-20D-25D3P 3420 MHT-20D-25D4P 3890 MHT-30D-3P MHT-40D-3P 3520 MHT-30D-40D4P 4000 DRTLRAIL (L) - DRTLRAIL (L)-2 DRTLRAIL (L)-3 DRTLRAIL (R)- DRTLRAIL (R)-2 DRTLRAIL (R) Pole Unit Arc Chutes Note: "*" New developed Microswitch "**" Please specify ACB rating & type while ordering for spares. 4. Arc Chutes For ACB Rating Qty. Required Per Pole* Unit Price 6D-6D/08N-20N(AHA) ARCCHT-06D-6D S(AHA) ARCCHT-20S 20D ARCCHT-20D D/30S(AHA) ARCCHT-25D D/40S(AHA) ARCCHT-30D D ARCCHT-40D 8790 **Voltage Code for Antipumping Relay 24/30V 48V 0V 220V 45V AC FA MA NA DC BD ED FD MD - 54 *Auxiliary Isolating Contact Blocks Description Unit Price Breaker & Cradle Side 2 Way AIH-BC 3680 *Auxiliary Isolating Contact Blocks has to be order together for Cradle & Breaker side. "*" To arrive at total quantity per ACB, multiply by 3 or 4 depending upon number of poles in the ACB. 42. Charging Motors (0V ac/dc) or (220V AC/DC) For ACB Rating Unit Price 6D-6D/08N-20S(AHA) AMH Communication Module Description Communication Module for Micropro 4. & 5. Release Power Supply Module Power Supply & Relay Module MicroPro 4. & 5. Release CSPSCM-MicroPro CSPSM-MicroPro CSPSRM-MicroPro Unit Price POR 20D-40D/30S-40S(AHA) AMH Battery Module for MicroPro 4. & 5. Release CS-MPBU4..

20 AH / AHA ACB Order Form

21 Capacitor Normal Duty Rating kvar Cylindrical Capacitor Rated Voltage LP / kvar Unit Price.0 CSPND V CSPND V CSPND V CSPND V CSPND V CSPND V CSPND V CSPND V CSPND V CSPND V CSPND V Heavy Duty Rating kvar Rated Voltage LP / kvar Unit Price.0 CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V CSPHD V Note: Capacitors are also available in 45/480/525V. For further details please contact nearest branch office. Normal Duty Rating kvar rectangular Capacitor Rated Voltage LP / kvar Unit Price.0 CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V CSSND V Extra Heavy Duty Rating kvar Rated Voltage LP / kvar Unit Price.0 CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V CSEHD V Super Heavy Duty Rating kvar Rated Voltage LP / kvar Unit Price.0 CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V CSSHD V

22

23 MRP w.e.f. 0 th June 203

24

25 MRP w.e.f. 0 th June 203

26

27 MCCB Moulded Case Circuit Breakers (Standard Packing includes insulating phase barrier and Hardware) Range 5A -200A, 690V Positive isolation Trip free mechanism Breaking capacity Ics=00% Icu Rated Current (Amps) 2 Pole MRP 3 Pole MRP 4 Pole MRP 4kA 5, 20, 30, 40, 50 CSCN2* 2350 CSCN3* 2650 CSCN4* kA 26kA 37kA 50kA 65kA 85kA 5, 20, 30, 40, 50 CSCS2* 2490 CSCS3* 3320 CSCS4* , 75, 00 CSC2N2* 2490 CSC2N3* 3320 CSC2N4* CSC4N2* CSC4N3* CSC4N4* POR POR POR 25 CSC4N2* CSC4N3* CSC4N4* 50, 75 CSC4N2* 6420 CSC4N3* 880 CSC4N4* CSC4N2* 8490 CSC4N3* 9320 CSC4N4* CSC4N2* 890 CSC4N3* 3460 CSC4N4* , 20, 30, 40, 50, 60 CSC3S2* 3540 CSC3S3* 4425 CSC3S4* , 00 CSC3S2* 3540 CSC3S3* 4425 CSC3S4* CSC3S2* 3620 CSC3S3* 4500 CSC3S4* , 75 - CSC4S3* 920 CSC4S4* CSC4S3* 0350 CSC4S4* CSC4S3* 3770 CSC4S4* u - CSC5N3* 280 CSC5N4* , 400 u - CSC5N3* CSC5N4* , CSC6N3* CSC6N4* , CSC6N3* 3200 CSC6N4* 440 5, 20, 30, 40, 50, 60 - CSC3H3* 7250 CSC3H4* , 00 - CSC3H3* 7350 CSC3H4* CSC3H3* 9320 CSC3H4* , 75 - CSC4H3* 2420 CSC4H4* CSC4H3* 500 CSC4H4* CSC4H3* 960 CSC4H4* u - CSC5S3* 2720 CSC5S4* , 400 u - CSC5S3* 2420 CSC5S4* , 300 u - CSC5H3* CSC5H4* , 400 u - CSC5H3* CSC5H4* , CSC6S3* CSC6S4* , CSC6S3* CSC6S4* u - CSC7S3* 9270 CSC7S4* u - CSC8S3* CSC8S4* , 300 u - CSC5L3* CSC5L4* , 400 u - CSC5L3* CSC5L4* , CSC6L3* 3330 CSC6L4* , CSC6L3* CSC6L4* u - CSC7L3* 0830 CSC7L4* u - CSC8L3* CSC8L4* Notes :. While Ordering, Replace "*" by Rated Current required. 2. u Spreader Terminals are included 3. For technical details please refer product catalogue

28 MCCB Moulded Case Circuit Breakers Accessories for MCCBs Suitable for use on New WB MCCBs Shunt Trip MRP Under Voltage Trip MRP Auxiliary Switch MRP Alarm Switch MRP CSCN2, CSCS2 STC-(...V) UVTC-(...V) AXWC-T ALWC-T CSCN3, CSCS3, CSCN4, CSCS4 STC-(...V) UVTC-(...V) AXWC-* ALWC-* CSC2N2 STC-(...V) UVTC-(...V) AXWC-T ALWC-T CSC2N3, CSC2N4 STC-(...V) 50 UVTC-(...V) 360 AXWC-* 780 ALWC-* CSC3S3, CSC3S4, CSC3H3, CSC3H4 STC-(...V) UVTC-(...V) AXWC-* ALWC-* CSC4N2 STC-(...V) UVTC-(...V) AXWC-T ALWC-T CSC4N3, CSC4N4, CSC4S3, CSC4S4, CSC4H3, CSC4H4 STC-(...V) UVTC-(...V) AXWC-* ALWC-* CSC5N3, CSC5N4, CSC5S3, CSC5S4, CSC5L3, CSC5L4 ST-6A(...V) UVT-6A(...V) ASW-6A ALSW-6A CSC6N3, CSC6N4, CSC6S3, CSC6S4, CSC6L3, CSC6L4 ST-6A(...V) UVT-6A(...V) ASW-6A ALSW-6A CSC7S3, CSC7S4, CSC7L3, CSC7L4 ST-7A(...V) UVT-7A(...V) ASW-7A ALSW-7A CSC8S3, CSC8S4, CSC8L3, CSC8L4 ST-7A(...V) UVT-7A(...V) ASW-7A ALSW-7A Suitable for use on New WB MCCBs Direct Rotary Handle MRP Direct Rotary Handle with Keylock MRP Extended Rotary Handle MRP CSCN3, CSCS3, CSCN4, CSCS4 DHC00 DHCK00 CSE-35S CSC2N3, CSC2N4 DHC00 DHCK00 CSE-35S CSC3S3, CSC3S4, CSC3H3, CSC3H4 DHC DHCK EHC CSC4N2 DHC250 DHCK250 EHC CSC4N3, CSC4N4, CSC4S3, CSC4S4, CSC4H3, CSC4H4 DHC250 DHCK250 EHC250 CSC5N3, CSC5N4, CSC5S3, CSC5S4, CSC5L3, CSC5L4 N-70S E-70U 2670 CSC6N3, CSC6N4, CSC6S3, CSC6S4, CSC6L3, CSC6L4 N-70M E-80U 2980 CSC7S3, CSC7S4, CSC7L3, CSC7L4 NA NA - CSC8S3, CSC8S4, CSC8L3, CSC8L4 NA NA - Notes:. Please replace "*" with R as MCCB left hand side position & T as MCCB right hand position 2. Left Hand Seat is not Available in 2Pole MCCBs. 3. For Frame Size upto 250AF, Shunt Trip available in 2VAC/DC, 24VAC/DC, 48VAC/DC, 60VAC/DC, 00-30VAC/DC, VAC/DC & VAC, VAC (Replace STC- (...V) by required voltage) 4. For Frame Size above than 250AF, Shunt Trip available in 24-48VAC/DC, VAC/DC, 0AC/DC, 220VAC/DC, 380~500VAC (Replace ST-6A (...V) by required voltage) 5. For Frame Size upto 250AF, Under Voltage Trip available in 24VAC/DC, 48VAC/DC, 00~0VAC/DC, 200~220VAC/DC & VAC, 440~480VAC (Replace UVTC-(...V) by required voltage) 6. For Frame Size above than 250AF, Under Voltage Trip available in 0VAC/DC, 220VAC/DC, 45VAC (Replace UVT-6A (...V) by required voltage) 7. Combination Switch with one Aux Switch+ One Alram Switch available upto 250AF. Order the same as follows: - Replace AXWC-T +ALWC-T with XLC-T (Combination Switch): MRP ` Replace AXWC-R +ALWC-R with XLC-R (Combination Switch): MRP ` Rotary Handle for Horizontal (Left & Right ) Mounting also available on request 9. Rotary Handle for 50AF & 00AF, 2Pole is not available 0. Metalic Extended Rotary Handle (Plastic Rotary Handle is also available (EHC00: MRP ` 940)) Plug-in devices For Rapid replacement of MCCB without opening terminal connection. The MCCB can be racked out by unscrewing top & bottom fixing screws. MCCB Plug in Base MRP CSC/CSC2 CSC3 CSC4 CSC5 CSC6 PB-A3-FR PB-C3-FR PB-D3-FR PB-I3-FR PB-J3-FR POR

29 MCCB Moulded Case Circuit Breakers *Enclosure for MCCBs (without MCCB) MCCB MODEL Rating (A) Suitable for use on MCCBs MRP New WinBreak / WiNbreak Upto 00A CSCN3 / CSCS3 / CSC2N3/CSCN4 / CSCS4 / CSC2N4 / CS2A3 / CS2A4 / CS2AA3 / CS2AA4 CS-CNM New WinBreak / WiNbreak 25A-250A CSC3S3 / CSC4N3 / CSC4S3 / CSC4H3/CSC3S4 / CSC4N4 / CSC4S4 / CSC4H4 / CS2B3 / CS3A3 / CS3B3 / CS2B4 / CS3A4 / CS3B4 CS-CNM New WinBreak / WiNbreak 250A-400A CSC5N3 / CSC5S3 / CSC5H3 / CSC5L3/CSC5N4 / CSC5S4 / CSC5H4 / CSC5L4 / CS4A3 / CS4A4 CS-ENCL AF 2850 New WinBreak 500A-800A CSC6N3 /CSC6S3/ CSC6L3/CSC6N4 /CSC6S4/ CSC6L4 CS-CNM New WinBreak 000A-200A CSC7S3 / CSC8S3 / CSC7L3 / CSC8L3/CSC7S4 / CSC8S4 / CSC7L4 / CSC8L4 CS-CNM Mechanical Interlock (Used to prevent mechanically closing together) Suitable for use on MCCBs Earth Fault Relay (with NCT) Suitable for 3 Phase 4 wire distribution network Rating (Amps) Earth Fault Relay Setting Range Applied between two MCCBs 40A 4~40A EFR25-AF-40(N) 00A 0~00A EFR25-AF-00(N) 25A 2.5~25A EFR25-AF-25(N) 200A 20~200A EFR250-AF A 25~250A EFR250-AF A 40~400A EFR400-AF A 63~630A EFR630-AF A 80~800A EFR800-AF A 00~000A EFR250-AF A 25~250A EFR250-AF-250 MRP CSC5N3, CSC5S3, CSC5H3,CSC5L3 MI-43S 3360 CSC5N4, CSC5S4, CSC5H4, CSC5L4 MI-44S 480 CSC6N3, CSC6S3, CSC6L3 MI-83S 480 CSC6N4, CSC6S4, CSC6L4 MI-84S 4940 MRP *Notes: ) code is for Enclosure only (without MCCB) 2) For placing an order for MCCB along with Enclosure, please apply Prefix E- before MCCB Code. For Price, please contact nearest Branch Office. Earth Fault Relay (Built in CBCT) Suitable for 3Phase 3 wire distribution network Rating (Amps) Earth Fault Relay Setting Range 32A 3.2~32A EFR-CBCT25-AF-32 40A 4~40A EFR-CBCT25-AF-40 63A 6.3~63A EFR-CBCT25-AF-63 80A 8~80A EFR-CBCT25-AF-80 00A 0~00A EFR-CBCT25-AF-00 25A 2.5~25A EFR-CBCT25-AF A 20~200A EFR-CBCT250-AF A 25~250A EFR-CBCT250-AF A 40~400A EFR-CBCT400-AF A 63~630A EFR-CBCT630-AF A 80~800A EFR-CBCT800-AF A 00~000A EFR-CBCT250-AF A 25~250A EFR-CBCT250-AF-250 MRP Terminal Covers Suitable for use on MCCBs For Line/Load Side 2Pole MRP 3Pole MRP 4Pole MRP CSCN, CSCS, CSC2N TCS2 TCS3 TCS4L (for Line) TCS4R(for Lord) 20 CSC3S,CSC3H - TCS23 TCS24L(for Line) TCS24R(for Lord) 370 CSC4N, CSC4S, CSC4H TCS33 TCS33 TCS34L(for Line) TCS34R(for Lord) 48 CSC5N, CSC53, CSC5H, CSC5L - - T-43A 050 T-44A 250 CSC6N, CSC6S, CSC6L - - T-63A 250 T-64A 570 Spreader Terminals for New WiNbreak MCCB Description MRP Std Pkg. (No's) For CSC/CSC2/CSC3-3 Pole CSET Set of 3 For CSC/CSC2/CSC3-4 Pole CSET Set of 4 For CSC4-3 Pole CSET Set of 3 For CSC4-4 Pole CSET Set of 4 For CSC5-3 Pole CSET Set of 3 For CSC5-4 Pole CSET Set of 4 For CSC6-3 Pole CSET Set of 3 For CSC6-4 Pole CSET Set of 4

30 MCCB WiNbreak Moulded Case Circuit Breakers (Standard packing includes extended terminals, insulating phase barrier and Hardware.) Positive isolation Trip free mechanism Range 5A - 200A, 600V Breaking capacity Icu at 45V AC Rated Current (Amps) 2 Pole MRP 3 Pole MRP 4 Pole MRP 0kA 4kA 5,0,5,20,30,40,50,60# CS2A2* 90 CS2A3* 20 CS2A4* ,00 CS2A2* 930 CS2A3* 260 CS2A4* 370 5,0,5,20,30,40,50,60# CS2AA2* 2050 CS2AA3* 2350 CS2AA4* ,00 CS2AA2* 200 CS2AA3* 2400 CS2AA4* , 75 CS3A2* 580 CS3A3* 6000 CS3A4* kA 200 CS3A2* 6830 CS3A3* 7950 CS3A4* CS3A2* 8760 CS3A3* 0430 CS3A4* ,20,30,40,50,60# CS2B2* 3470 CS2B3* 4360 CS2B4* ,00 CS2B2* 3520 CS2B3* 440 CS2B4* , 75 CS3B2* 6400 CS3B3* 7970 CS3B4* kA 200 CS3B2* 8450 CS3B3* 9030 CS3B4* CS3B2* 850 CS3B3* 350 CS3B4* CS4A3* CS4A4* POR 350, CS4A3* CS4A4* POR 5,20,30,40,50,60# - - CS2C3* CS2C4* 75, CS2C3* CS2C4* CS3C3* CS3C4* CS3C3* CS3C4* product discontinue - available till stock last 35kA 50kA 65kA 75, CS3C3* CS3C4* POR CS3C3* CS3C4* 250, CS4B3* CS4B4* 350, CS4B3* CS4B4* 500, CS5A3* CS5A4* 700, CS5A3* CS5A4* 250, CS4C3* CS4C4* 350, CS4C3* CS4C4* POR 500, CS5B3* CS5B4* 700, CS5B3* CS5B4* 25,50,75, CS3D3* CS3D4* CS6B3* POR CS6B4* CS7B3* CS7B4* POR POR POR 250, CS4D3* CS4D4* 85kA 350, CS4D3* CS4D4* POR 500, CS5D3* CS5D4* 700, CS5D3* CS5D4* POR Notes :. While Ordering, Replace "*" by Rated Current required. 2. # Spreader Terminals are not included.

31 MCCB WiNbreak Moulded Case Circuit Breakers - Accessories Electrical Auxiliaries Suitable for use on MCCBs For correct selection of ASW & ALSW, refer Picture CS Shunt & UVT are mounted on Right-hand Seat (T) Shunt Trip Under Voltage Trip Auxiliary Switch Alarm Switch Direct Rotary Handle MRP MRP MRP MRP MRP Extended Rotary Handle MRP CS2A3/CS2A4 ST-A(..V) UVT-A(..V) ASW-A(R)* ALSW-A(R) D-35S 050 CSE-35S 940 CS2A2 ST-A(..V) UVT-A(..V) ASW-A(T)* ALSW-A(T) - - CS2B3/B4,CS2C3/C4 ST-B(..V) UVT-B(..V) ASW-B(R)* ALSW-B(R) D-45S CSE CS2B2 ST-B(..V) UVT-B(..V) ASW-B(T)* ALSW-B(T) D-45S CSE CS3A3/A4,CS3B3/B4,CS3C3/C4 ST-C(..V) UVT-C(..V) ASW-C(R)* ALSW-C(R) D-55S CSE CS3A2,CS3B2 ST-C(..V) UVT-C(..V) ASW-C(T)* ALSW-C(T) D-55S NA CSD3,CS2D3 ST-4A(..V) UVT-4A(..V) ASW-4A(R)* ALSW-4A(R) N-55 NA CSD4,CS2D4 ST-4B(..V) UVT-4B(..V) ASW-4A(T)* ALSW-4A(T) N-55 NA CS3D3 ST-5A(..V) UVT-5A(..V) ASW-5A(R)* ALSW-5A(R) N-60 NA CS3D4 ST-5B(..V) UVT-5B(..V) ASW-5A(T)* ALSW-5A(T) N-60 NA CS4A3/A4,CS4B3/B4, ST-6A(..V) UVT-6A(...V) ASW-6A ALSW-6A N-70S E-70U CS4C3/C4,CS4D3/D4, ST-6A(..V) UVT-6A(...V) ASW-6A ALSW-6A N-70S E-70U CS5A3/A4,CS5B3/B4, ST-6A(..V) UVT-6A(...V) ASW-6A ALSW-6A N-70M E-80U CS5C3/C4,CS5D3/D4 ST-6A(..V) UVT-6A(...V) ASW-6A ALSW-6A N-70M E-80U 2980 CS6B3/B4,CS7B3/B4 ST-7A(..V) 5750 UVT-7A(...V) 5750 ASW-7A 300 ALSW-7A 300 NA - *Please read R as MCCB left hand side position & T as right hand position Notes :. While Ordering Replace "*" by Rated Current required. 2. Shunt Trip Coil & UVT available in 24, 48V,0V,220V & 45V AC/DC (Replace by required Voltage). 220V & 45V are standard stock items. UVT - 6A not available in 24V AC/DC. ( not available for 000A & 200A MCCBs) 3. Single block for one Aux. Sw +one Alarm Switch available upto 225AF. Order the same as follows: - Replace ASW-A+ALSW-A to XL-A(T) - Replace ASW-B+ALSW-B to XL-B(T) - Replace ASW-C+ALSW-C to XL-C(T) 4. Rotary handle for Horizontal (Left&Right) mounting also available on request. 5. Rotary Handle for 50AF & 00AF, 2Pole not available. 6. Metallic Extended rotary handle Left-hand Seat (R*) Right-hand Seat (T*) *Please read R as MCCB left hand side position & T as right hand position Please refer above auxiliary selection for 3 & 4 Pole WiNbreak MCCB Only

32 MCCB WiNbreak2 Moulded Case Circuit Breakers Exeptional current limiting device with double break contacts (Ics=Icu=00%) Positive isolation Double Break Trip free mechanism 00% Neutral Protection in 4 Pole Interchangeable Trip Unit FMU (Thermal Magnetic) Release Adjustable Overload 80-00% Fixed short circuit Breaking capacity Ics=00% Icu Rated Current (Amps) 3 Pole MRP 4 pole MCCBs are with Neutral protection against overload and shortcircuit 4 Pole MRP 6, 20, 25, 32, 40, 50, 63, 80, 00# CD00SFMU*3P CD00SFMU*4P 37kA 25A CD60SFMU*3P CD60SFMU*4P 60A CD60SFMU*3P POR CD60SFMU*4P 200A CS250SFMU*3P CS250SFMU*4P POR 250A CS250SFMU*3P CS250SFMU*4P 6, 20, 25, 32, 40, 50, 63, 80, 00 CD00NFMU*3P 8320 CD00NFMU*4P A CD60NFMU*3P 0900 CD60NFMU*4P A CD60NFMU*3P 3400 CD60NFMU*4P kA 25 CS60NFMU*3P CS60NFMU*4P POR 60 CS60NFMU*3P CS60NFMU*4P POR 200 CS250NFMU*3P 980 CS250NFMU*4P CS250NFMU*3P CS250NFMU*4P & 400 CS400NFMU*3P 2570 CS400NFMU*4P kA 500 & 630 CS630NFMU*3P CS630NFMU*4P CS800NFMU*3P CS800NFMU*4P 660 ATU (Thermal Magnetic) Release Adjustable Overload 80-00% Adjustable Short circuit 5-0 In Breaking capacity Ics=00% Icu Rated Current (Amps) 3 Pole MRP 4 pole MCCBs are with Neutral protection against overload and shortcircuit 4 Pole MRP 37kA 200A CS250SATU*3P CS250SATU*4P POR 250A CS250SATU*3P CS250SATU*4P POR 25 CS60NATU*3P 2080 CS60NATU*4P kA 60 CS60NATU*3P 5020 CS60NATU*4P CS250NATU*3P 9690 CS250NATU*4P CS250NATU*3P CS250NATU*4P & 400 CS400NATU*3P CS400NATU*4P kA 500 & 630 CS630NATU*3P 3060 CS630NATU*4P CS800NATU*3P CS800NATU*4P ETS (Microprocessor based) Release Adjustable Overload 40-00% Adjustable shortcircuit.5-0 In Breaking capacity Ics=00% Icu Rated Current (Amps) 3 Pole MRP 4 pole MCCBs are with Neutral protection against overload and shortcircuit 4 Pole MRP 50kA 40, 80, 60 CS60NETS*3P CS60NETS*4P CS250NETS*3P CS250NETS*4P , 250, 400 CS400NETS*3P CS400NETS*4P kA 60, 250, 400, 630 CS630NETS*3P CS630NETS*4P , 800 CS800NETS*3P CS800NETS*4P 86500

33 MCCB WiNbreak2 Moulded Case Circuit Breakers ETM (Microprocessor Release with in-built Earth fault Protection) Adjustable Overload 40-00% Adjustable shortcircuit.5-0 In Breaking capacity Ics=00% Icu Rated Current (Amps) 3 Pole MRP 4 pole MCCBs are with Neutral protection against overload and shortcircuit 4 Pole MRP 65kA 60 CS400NETM3360A3PE CS400NETM3360A4PE 250 CS400NETM33250A3PE CS400NETM33250A4PE 400 CS400NETM33400A3PE POR CS400NETM33400A4PE 400, 630 CS630NETM33*A3PE CS630NETM33*A4PE 630, 800 CS800NETM43*A3PE CS800NETM43*A4PE POR. Spreader Terminals are not included for MCCBs upto 63A 2. Replace "*" with required current range 3. MCCB with microprocessor release having Ammeter function, ZSI & communication port is also available. For prices contact nearest branch office. 4. MCCB for Motor Protection with Magnetic Trip release is also available. For prices contact nearest branch office. 5. WiNbreak2 MCCBs are available up to Icu=Ics=50kA for entire range for higher short circuit level, Price avialable on request. Moulded Case Circuit Breakers - Accessories Internal Accessories Description MRP Aux. Switch Alarm Switch Fault Alarm Switch AX-T AL-T FAL-T 00 Shunt trip coil ST-T* 2530 UVT coil UVT-T* 3430 Notes : ) The above accessories are common to entire WiNbreak2 MCCBs. 2) Shunt Trip available in 2V DC, 24V AC/DC, 48V AC/DC, 0-30V AC/DC, V AC, 250V DC & V AC 3) Under Voltage Trip available in 24V AC/DC, 48V AC/DC, 0-30V AC/DC, V AC, 250V DC, V AC & V AC Rotary Handle Suitable for MCCB Type Direct Direct Rotary Handle with Keylock Extended MRP MRP CD 00 & 60 DH-S 370 EH-S 2060 CS 60 & 250 DH2-S 490 EH2-S 2470 CS 400 & 630 DH3-S 2920 EH3-S 3840 CS 800 DH4-S 3490 EH4-S 4530 Description MRP CD 00 & 60 DHK-S 3900 CS 60 & 250 DHK2-S 400 CS 400 & 630 DHK3-S 4300 CS 800 DHK4-S 4480 Spreader Terminals Description MRP For CS400 & CS630, 3Pole CSCETSP Set of 3 For CS400 & CS630, 4Pole CSCETSP Set of 4 For CS800, 3Pole CSET Set of 3 For CS800, 4Pole CSET Set of 4 Padlocking Device Suitable for MCCB Type MRP CD 00 / 60 PHL 200 CS 60 / 250 PHL CS 400 / 630 PHL CS 800 PHL CD 00 / 60 PL 700 CS 60 / 250 PL CS 400 / 630 PL 3 00 CS 800 PL 4 50 PHL - Fixed Type PL - Removable Type Plug-in Base Description MRP CD 00 / 60 3P PB CS 60 / 250 3P PB CS 400 / 630 3P PB CS 800 3P PB Motor Operator - For remote "ON/OFF" operation only Suitable for MCCB Type Motor Type Control Voltage MRP Mechanical Interlock Device 3 Pole 4 Pole Suitable for MCCB Type MRP MRP CD00 & 60 CS60, 250 MOP MOP2 24V DC, V AC & V DC 24V DC, 0V AC/DC & 220V DC, 230V AC CD00 & 60 MIT MIT4 70 CS60 & 250 MIT MIT CS400, 630 MOP3 24V DC, 0V AC/DC & 220V DC, 230V AC CS 400 & 630 MIT MIT CS 800 MIT MIT CS800 MOP4 24V DC, 0V AC/DC & 220V DC, 230V AC 40060

34 MCCB WiNbreak Moulded Case Circuit Breakers (Standing Packing includes insulating phase barrier and Hardware) Range 6A -250A, 690V Positive Isolation Trip Free mechanism FMU (Thermal Magnetic) Release Adjustable Overload 80-00% Fixed short circuit Breaking capacity Ics = 00%Icu Rated Current (Amps) 3 Pole MRP 4 Pole MRP 25kA 6, 20, 25, 32, 40, 50 CSEM25FMU3P-* 4575 CSEM25FMU4P-* kA 6, 20, 25, 32, 40, 50 CSEN25FMU3P-* 5800 CSEN25FMU4P-* 7250 ATM (Thermal Magnetic)Release Adjustable Overload 80-00% Adjustable Short Circuit 5-0 In Breaking capacity Ics = 00%Icu Rated Current (Amps) 3 Pole MRP 4 Pole MRP 63, 80, 00 CSEM25ATM3P-* 4600 CSEM25ATM4P-* CSEM25ATM3P-* 6600 CSEM25ATM4P-* kA 60 CSE2M250ATM3P-* 9950 CSE2M250ATM4P-* CSE2M250ATM3P-* 250 CSE2M250ATM4P-* CSE2M250ATM3P-* 3850 CSE2M250ATM4P-* , 80, 00 CSEN25ATM3P-* 5900 CSEN25ATM4P-* CSEN25ATM3P-* 8050 CSEN25ATM4P-* kA 60 CSE2N250ATM3P-* 0300 CSE2N250ATM4P-* CSE2N250ATM3P-* 90 CSE2N250ATM4P-* CSE2N250ATM3P-* 4460 CSE2N250ATM4P-* 990 Notes :. While Ordering, Replace"*" by Rated Current required. 2. For technical details please refer product catalogue 3. Spreader Terminals are not included. For prices, please refer page no. 37 Accessories Description 4 MRP Aux Switch AXW-* 80 Alarm Switch ALW-* 80 Combined Switch(Aux+Alarm) XLW-* 050 Shunt trip Coil STW-(...) 600 Mechanical Interlock Frame Size 3 Pole 4 Pole MRP CSE MIW-25-3P MIW-25-4P 2550 CSE2 MIW-250-3P MIW-250-4P 2650 Locking Devices Frame Size Key Lock* MRP Padlock MRP CSE KLW PLW CSE2 KLW PLW *Will be supplied only Factory fitted. UVT Coil UVTW-(...) 2750 Extended Rotary Handle, CSE EHW Extended Rotary Handle, CSE2 EHW The internal accessories are common to entire WinBreak MCCBs. Please Replace "*" with L as MCCB Left hand side position & R as MCCB Right hand position. Shunt Trip available in 24VDC, 48VDC, 0VDC, 220VDC & 220VAC, 45VAC (Replace STW-(...) by required voltage) 2. Under Voltage Release in 24VDC, 48VDC, 0VDC, 220VDC & 220VAC, 45VAC (Replace UVTW-(...) by required voltage) 3. Maximum possibilities for internal accessories - Left Hand Seat: AXW or ALW or XLW or STW or UVTW - Right Hand Seat: AXW or ALW or XLW

35 MCCB WiNbreak MCCB with Microprocessor Release 'MicroPro WB' Conforms to IS/IEC Range : 40 to 250A, 3P & 4P Breaking Capacity : 25kA/ 35kA/50kA Ics = 00% Icu Suitable for Isolation Adjustable Over Load from In Adjustable Short Circuit from 2-2Ir Inbuilt Ground fault Protection available 20% to 00% of In Adjustable neutral overload protection available : 50% to 00% of Ir Adjustable Current imbalance protection available : (30% - 70%) of Ir Provision of Thermal Memory : ON/OFF Communication using RS485 through MODBUS Protocol View Last Trip information LCD : Indication of Measurement and information Wide Range of Internal and External Accessories ETM (Microprocessor Release with in-built Earth fault Protection) Adjustable Overload 40-00% Adjustable shortcircuit 2~2 Ir Release Range (A) Breaking Capacity Icu at 45V AC 3 Pole MRP 4 Pole MRP 6-40A CSEN25ETM3P-40A CSEN25ETM4P-40A 25-63A CSEN25ETM3P-63A CSEN25ETM4P-63A 40-00A CSEN25ETM3P-00A CSEN25ETM4P-00A 50-25A 35kA CSEN25ETM3P-25A CSEN25ETM4P-25A 63-60A CSE2N250ETM3P-60A CSE2N250ETM4P-60A A CSE2N250ETM3P-200A CSE2N250ETM4P-200A A CSE2N250ETM3P-250A CSE2N250ETM4P-250A POR 6-40A CSES25ETM3P-40A CSES25ETM4P-40A POR 25-63A CSES25ETM3P-63A CSES25ETM4P-63A 40-00A CSES25ETM3P-00A CSES25ETM4P-00A 50-25A 50kA CSES25ETM3P-25A CSES25ETM4P-25A 63-60A CSE2S250ETM3P-60A CSE2S250ETM4P-60A A CSE2S250ETM3P-200A CSE2S250ETM4P-200A A CSE2S250ETM3P-250A CSE2S250ETM4P-250A Notes: Spreader Terminals are not included. Single Pole - Moulded Case Circuit Breakers (Standing Packing includes insulating phase barrier and Hardware) Positive Isolation Trip Free mechanism FTM (Thermal Magnetic) Release Fixed Overload Fixed short circuit Breaking Capacity (Ics=00%Icu) at 240V AC Rating (A) MRP 6, 20, 25, 32, 40, 50, 63, 80, 00* CSE0K00FTMP-* 6, 20, 25, 32, 40, 50, 63* CSEK25FTMP-* 8kA 80, 00 CSEK25FTMP-* 25 CSEK25FTMP-* 60 CSEK25FTMP-* POR 6, 20, 25, 32, 40, 50, 63* CSEL25FTMP-* 25kA 80, 00 CSEL25FTMP-* 25 CSEL25FTMP-* 60 CSEL25FTMP-* Note:. While Ordering, Replace "*" by Rated Current required. 2. For technical details please refer product catalogue. 3. *Extended Terminals are not included 4. Also available in 36kA for further detail please contact Branch Office.

36 MCCB ACE 2 Moulded Case Circuit Breakers Positive isolation Double Break Trip free mechanism Thermal Magnetic Release (Adjustable Overload & Short Circuit setting) Breaking Capacity Ics=00% Icu at 45V AC (ka) Rated Current (Amps) 3 Pole MRP 4 Pole MRP 36kA 50kA Adjustable Overload Fixed Short Circuit Adjustable Overload Adjustable Short Circuit Adjustable Overload Fixed Short Circuit Adjustable Overload Adjustable Short Circuit 6, 20, 25, 32, 40, 50, 63 CSCN25TM*3P 740 CSCN25TM*4P ,00 CSCN25TM*3P 7350 CSCN25TM*4P CSCN25TM*3P 8420 CSCN25TM*4P , 80 CSCN250TM*3P 0970 CSCN250TM*4P CSCN250TM*3P 2580 CSCN250TM*4P CSCN250TM*3P 530 CSCN250TM*4P , 20, 25, 32, 40, 50, 63 CSCS25TM*3P 7360 CSCS25TM*4P , 00 CSCS25TM*3P 7570 CSCS25TM*4P CSCS25TM*3P 0870 CSCS25TM*4P CSCS250TM*3P 3320 CSCS250TM*4P CSCS250TM*3P 7800 CSCS250TM*4P CSCS250TM*3P 2200 CSCS250TM*4P Spreader Terminal are not included. Microprocessor Release LSIN - Adjustable Overload, Short Circuit, Instantaneous and Neutral Protection Breaking Capacity Ics=00% Icu at 45V AC (ka) Rated Current (Amps) 3 Pole MRP 4 Pole MRP 40,00,25 CSCN25EM*3P 300 CSCN25EM*4P kA 50kA 70kA 60 CSCN250EM*3P 4070 CSCN250EM*4P CSCN250EM*3P 7800 CSCN250EM*4P CSCN250EM*3P CSCN250EM*4P ,00 CSCS25EM*3P 3300 CSCS25EM*4P CSCS25EM*3P 400 CSCS25EM*4P CSCS250EM*3P 750 CSCS250EM*4P CSCS250EM*3P 2620 CSCS250EM*4P CSCS250EM*3P CSCS250EM*4P , 350, 400 CSCS400EM*3P CSCS400EM*4P 500, 630 CSCS630EM*3P CSCS630EM*4P 700, 800 CSCS800EM*3P CSCS800EM*4P 000 CSCS250EM*3P CSCS250EM*4P 250 CSCS250EM*3P CSCS250EM*4P 40,00 CSCH25EM*3P CSCH25EM*4P 25 CSCH25EM*3P CSCH25EM*4P 60 CSCH250EM*3P POR CSCH250EM*4P POR 200 CSCH250EM*3P CSCH250EM*4P 250 CSCH250EM*3P CSCH250EM*4P 35, 350, 400 CSCH400EM*3P CSCH400EM*4P 500, 630 CSCH630EM*3P CSCH630EM*4P 700, 800 CSCH800EM*3P CSCH800EM*4P 000 CSCH250EM*3P CSCH250EM*4P 250 CSCH250EM*3P CSCH250EM*4P Notes :. While Ordering, Replace "*" by Rated Current required. 2. Spreader Terminal are not included - Please refer table on page no For technical details please refer product catalogue

37 MCCB ACE 2 Moulded Case Circuit Breakers Accessories Internal Accessories Description Frame Voltage 220V AC 380/45V AC 24V DC 0V DC MRP Shunt Release U/V Release CSCN25TM STC92 STC95 STC CSC*25EM CSC*250EM CSCN250TM CSC*400EM CSC*630EM CSC*800EM STC93 STC96 STC CSC*250EM STC94 STC97 STC00 STC0 POR CSCN25TM UVTC02 UVTC CSC*25EM CSC*250EM CSCN250TM UVTC03 UVTC CSC*400EM CSC*630EM CSC*800EM CSC*250EM UVTC04 UVTC POR Motor Operator Aux/Alarm Contacts MCCB Type Voltage MRP CSC*25TM MOPC-88 24V DC, V AC, V DC 520 CSC*25/250EM 24V DC, V AC, MOPC-89 CSCN250TM V DC 9390 CSC*400/630EM MOPC-90 24V DC, 0V AC/DC 220V DC, 230V AC POR CSC*800/250EM MOPC-9 230V AC, 400V AC Spreader Terminals Description MRP For CSCS400/CSCH400, 3 Pole CSCETSP Set of 3 For CSCS400/CSCH400, 4 Pole CSCETSP Set of 4 For CSCS630/CSCH630, 3 Pole CSCETSP Set of 3 For CSCS630/CSCH630, 4 Pole CSCETSP Set of 4 Description MRP Auxiliary Contact(Left) AXC-L Auxiliary Contact(Middle) AXC-M 880 Auxiliary Contact(right) AXC-R Alarm Contact ALC 980 Extended Rotary Handle Description 3 Pole 4 Pole MRP CSCN25TM/CSCS25TM EC-55 EC CSC*25EM CSC*250EM CSCN250TM/CSCS250TM EC-56 EC For CSCS800/CSCH800, 3 Pole CSCET Set of 3 For CSCS800/CSCH800, 4 Pole CSCET Set of 4 For CSCS250/CSCH250, 3 Pole CSCET Set of 3 For CSCS250 / CSCH250, 4 Pole CSCET Set of 4 CSC*400EM CSC*630EM CSC*800EM CSC*250EM EC-57 EC-58 EC-2 EC-58 POR MCCB Spreaders (extended terminals) for use with MCCB type Description WiNbreak New WiNbreak WinBreak2 WinBreak ACE2 MRP CSET033 For 00AF, 3 Pole Upto 25AF, 3 Pole For CD00/60, 3 Pole For 25AF, 3 Pole For 25AF, 3Pole, TM Release 20 Set of 3 CSET044 For 00AF, 4 Pole Upto 25AF, 4 Pole For CD00/60, 4 Pole For 25AF, 4 Pole For 25AF, 4Pole, TM Release 200 Set of 4 CSET2533 For 250AF, 3 Pole For 250AF, 3 Pole For CS60/250AF 3 Pole For 250AF, 3 Pole For 250AF, 3Pole, TM Release & Upto 250AF, 3Pole, EM Release 320 Set of 3 CSET2544 For 250AF, 4 Pole For 250AF, 4 Pole For CS60/250AF 4Pole For 250AF, 4 Pole For 250AF, 4Pole, TM Release & Upto 250AF, 4Pole, EM Release 480 Set of 4

38 Switch Disconnector Fuse Unit New Test Position SDF Without Fuse Links Rating (A) Pole MRP MRP Recommended Fuse Link # 32 TPN CSCSDF32SN2CGF E-CSCSDF32SN2CGF CGF 63 TPN CSCSDF63SN2CHF E-CSCSDF63SN2CHF CHF Auxiliary Contacts Description MRP NO +NC for Comapct SDF CSDFAUX 425 2NO +2NC for Comapct SDF CSDFAUX Extension Shaft for Handle Rating MRP 32~63A CSP6X4 200 Spare Auxiliary TEST Block Description MRP 32~63A TSTAUX 630 Spare Handle Rating MRP 32~63A CSTH 80 S6 260

39 Switch Disconnector Fuse Unit Switch Disconnector Fuse Unit without Fuse Links LT Heavy Duty Switch Disconnector Fuse Unit CSSDF 32A - 800A, 45V, 50Hz complete with Handle Assembly having Door Interlock and Padlocking arrangement Rating Amps 32A 63A 00A 25A 60A 200A 250A 35A 400A 630A 800A Pole CSSDF in Open Execution CSSDF in Sheet Steel Enclosure Recommended Fuse Links Type (IEC Size) MRP MRP MRP MRP DIN BS DIN BS DIN BS 2P CSSDF32D2 CSSDF32B2 TP CSSDF32D3 370 CSSDF32B3 50 E-CSSDF32D3 POR E-CSSDF32B3 POR TPN CSSDF32D3N 480 CSSDF32B3N 560 E-CSSDF32D3N 3020 E-CSSDF32B3N P CSSDF32D4FN 2060 CSSDF32B4FN 230 E-CSSDF32D4FN 3350 E-CSSDF32B4FN P CSSDF63D2 CSSDF63B2 TP CSSDF63D3 970 CSSDF63B3 940 E-CSSDF63D3 POR E-CSSDF63B3 POR TPN CSSDF63D3N 2240 CSSDF63B3N 2050 E-CSSDF63D3N 3840 E-CSSDF63B3N P CSSDF63D4FN 2520 CSSDF63B4FN 2540 E-CSSDF63D4FN 3990 E-CSSDF63B4FN P CSSDF00D2 CSSDF00B2 TP CSSDF00D CSSDF00B3 40 E-CSSDF00D3 POR E-CSSDF00B3 POR TPN CSSDF00D3N 4700 CSSDF00B3N 4330 E-CSSDF00D3N 6550 E-CSSDF00B3N 620 4P CSSDF00D4FN 5680 CSSDF00B4FN 5820 E-CSSDF00D4FN 7320 E-CSSDF00B4FN 720 2P CSSDF25D2 CSSDF25B2 TP CSSDF25D CSSDF25B3 480 E-CSSDF25D3 POR E-CSSDF25B3 POR TPN CSSDF25D3N 5030 CSSDF25B3N 5080 E-CSSDF25D3N 7580 E-CSSDF25B3N 730 4P CSSDF25D4FN 6480 CSSDF25B4FN 6400 E-CSSDF25D4FN 7800 E-CSSDF25B4FN P CSSDF60D2 CSSDF60B2 TP CSSDF60D CSSDF60B3 570 E-CSSDF60D3 POR E-CSSDF60B3 POR TPN CSSDF60D3N 6020 CSSDF60B3N 5820 E-CSSDF60D3N 8290 E-CSSDF60B3N P CSSDF60D4FN 7330 CSSDF60B4FN 7380 E-CSSDF60D4FN 030 E-CSSDF60B4FN P CSSDF200D2 CSSDF200B2 TP CSSDF200D3 640 CSSDF200B E-CSSDF200D3 POR E-CSSDF200B3 POR TPN CSSDF200D3N 6900 CSSDF200B3N 6840 E-CSSDF200D3N 9480 E-CSSDF200B3N P CSSDF200D4FN 8390 CSSDF200B4FN 8305 E-CSSDF200D4FN 0930 E-CSSDF200B4FN 370 2P CSSDF250D2 CSSDF250B2 TP CSSDF250D CSSDF250B E-CSSDF250D3 POR E-CSSDF250B3 POR TPN CSSDF250D3N 8440 CSSDF250B3N 8480 E-CSSDF250D3N 370 E-CSSDF250B3N P CSSDF250D4FN 9830 CSSDF250B4FN 9840 E-CSSDF250D4FN 2490 E-CSSDF250B4FN 360 2P CSSDF35D2 CSSDF35B2 TP CSSDF35D CSSDF35B E-CSSDF35D3 POR E-CSSDF35B3 POR TPN CSSDF35D3N 320 CSSDF35B3N 0870 E-CSSDF35D3N 40 E-CSSDF35B3N P CSSDF35D4FN 490 CSSDF35B4FN 3750 E-CSSDF35D4FN 690 E-CSSDF35B4FN P CSSDF400D2 CSSDF400B2 TP CSSDF400D CSSDF400B E-CSSDF400D3 POR E-CSSDF400B3 POR TPN CSSDF400D3N 400 CSSDF400B3N 300 E-CSSDF400D3N 680 E-CSSDF400B3N P CSSDF400D4FN 6560 CSSDF400B4FN 6350 E-CSSDF400D4FN 7920 E-CSSDF400B4FN P CSSDF630D2 CSSDF630B2 TP CSSDF630D CSSDF630B E-CSSDF630D3 POR E-CSSDF630B3 POR TPN CSSDF630D3N CSSDF630B3N 2870 E-CSSDF630D3N E-CSSDF630B3N P CSSDF630D4FN CSSDF630B4FN 2380 E-CSSDF630D4FN 2900 E-CSSDF630B4FN P CSSDF800D2 CSSDF800B2 TP CSSDF800D CSSDF800B E-CSSDF800D3 POR E-CSSDF800B3 POR TPN CSSDF800D3N CSSDF800B3N 2760 E-CSSDF800D3N POR E-CSSDF800B3N P CSSDF800D4FN CSSDF800B4FN E-CSSDF800D4FN POR E-CSSDF800B4FN CDFL00 (32) CDFL00 (63) CDFL00 (00) CDFL00 (25) CDFL00 (60) CDFL--200 CDFL--250 CDFL-2-35 CDFL CDFL CTIA-32 (A2) CTIS-63 (A3) CTCP-00 (A4) CTCP-25 (A4) CTF-60 (B2) CTF-200 (B2) CTK F-250(B3) CTKF-35 (B3) CTMF-400 (B4) CTTM-630 (C2) - CTLM-800 (C3) Notes: * 2 Pole switch prices available on request.

40 Switch Disconnector Fuse Unit Accessories Switch Disconnector Fuse Unit Key Interlocks (3 Locks - 2 Keys) For Switch Type MRP CSSDF 32A - 60A CSSDFZW CSSDF 200A - 800A CSSDFZW Spare Poles ( Price per Pole ) Rating (Amps) DIN BS MRP 32 CSSDF-SP-32D CSSDF-SP-32B 80 Castle Key Locks 63 CSSDF-SP-63D CSSDF-SP-63B 040 CSSDF 32A - 60A CSSDF 200A - 800A CSSDFZW-5 CSSDFZW CSSDF-SP-00D CSSDF-SP-00B CSSDF-SP-25D CSSDF-SP-25B 250 Auxiliary Contacts NO + NC CSSDF 32A - 63A for 3P CSSDFZX NO + 2 NC CSSDF 32A - 63A for 3P CSSDFZX NO + NC CSSDF 32A - 63A for 2P & 4P CSSDFZX 46B NO + 2 NC CSSDF 32A - 63A for 2P & 4P CSSDFZX 32B 840 NO + NC CSSDF 00A - 60A CSSDFZX NO + 2 NC CSSDF 00A - 60A CSSDFZX NO + NC CSSDF 200A - 400A CSSDFZX NO + 2 NC CSSDF 200A - 400A CSSDFZX NO + NC CSSDF 630A - 800A CSSDFZX NO + 2 NC CSSDF 630A - 800A CSSDFZX CSSDF-SP-60D CSSDF-SP-60B CSSDF-SP-200D CSSDF-SP-200B CSSDF-SP-250D CSSDF-SP-250B CSSDF-SP-35D CSSDF-SP-35B CSSDF-SP-400D CSSDF-SP-400B CSSDF-SP-630D CSSDF-SP-630B CSSDF-SP-800B 9940 Spare Handle Shaft CSSDF 32A-60A CSP6x65 20 CSSDF 200A-800A CSP2x Handle Mounting Kit (for independent mounting of O/E Switches) CSSDF 200A - 400A HMK CSSDF 630A - 800A HMK Extended Terminals TPN ET A-63A 4P ET TPN ET A-60 4P ET TPN ET A-400A 4P ET Spare Spare Neutral Links For Switch Type CSSDF 32A-63A CSSDF ZX CSSDF 00A-60A CSSDF ZX CSSDF 200A-400A CSSDF ZX CSSDF 630A-800A CSSDF ZX Spare Handle For Switch Type CSSDF 32A-60A (Moulded) CSWH 80 S6 470 CSSDF 200A-400A (Moulded) CSWH 45 S2 80 CSSDF 630A-800A (Moulded) CSWH 220 S2 030 Switch Disconnector Fuse unit with various options Fuse Cover and Terminal Shroud are also on request 200A DIN/BS~630A DIN Centre Mechanism, Fuse Cover and Terminal Shroud are also on request 200A DIN/ BS~630A DIN

41 Switch Disconnector Switch Disconnectors (Load Break Switches) "*" Moulded Pole Construction LT Heavy Duty Load Break Switches CSSD 25A - 25A, 45V, 50Hz complete with Rotary Handle Assembly having door interlock and padlocking arrangement. Handle colour: Red Knob and Yellow Base (standard) Black Base and Knob on request. Rating Amps Pole CSSD In Open Execution In Sheet Steel Enclosure MRP MRP 3 CSSD25D3 80 E-CSSD25D CSSD25D4 500 E-CSSD25D CSSD40D3 500 E-CSSD40D CSSD40D E-CSSD40D CSSD63K3 830 E-CSSD63K CSSD63D E-CSSD63D CSSD25D E-CSSD25D CSSD25D E-CSSD25D "*" The above switches are available with door defeate Mechanism / Pistol grip handle. Modular Pole construction LT Heavy Duty Load Break Switches CSSD 25A - 350A, 45V, 50Hz complete with Handle Assembly having door interlock and padlocking arrangement. CSSD In Open Execution In Sheet Steel Enclosure Rating Amps Pole MRP MRP 2 CSSD25DM CSSD25DM E-CSSD25DM P Series K Series Refer Compact series for A (DM Series) 4 CSSD25DM E-CSSD25DM CSSD60DM CSSD60DM E-CSSD60DM CSSD60DM4 600 E-CSSD60DM CSSD200DM CSSD200DM E-CSSD200DM CSSD200DM E-CSSD200DM CSSD250DM CSSD250DM3 760 E-CSSD250DM CSSD250DM E-CSSD250DM CSSD35DM CSSD35DM E-CSSD35DM CSSD35DM4 360 E-CSSD35DM CSSD400DM CSSD400DM3 260 E-CSSD400DM CSSD400DM E-CSSD400DM CSSD630K CSSD630K E-CSSD630K CSSD630K E-CSSD630K CSSD800K CSSD800K E-CSSD800K CSSD800K E-CSSD800K CSSD000P CSSD000P E-CSSD000P CSSD000P E-CSSD000P CSSD250P CSSD250P E-CSSD250P CSSD250P E-CSSD250P CSSD600P CSSD600P E-CSSD600P CSSD600P E-CSSD600P CSSD2000P E-CSSD2000P CSSD2000P E-CSSD2000P CSSD2500P E-CSSD2500P CSSD2500P E-CSSD2500P CSSD350P E-CSSD350P CSSD350P E-CSSD350P Notes: 'K' series from 000A to 350A in open execution is also available on special request for retrofit jobs only. For price, please contact nearest Branch Office.

42 Switch Disconnector Moulded Switches Moulded in Plastic Enclosure Rating Amps Pole Colour Box Handle Grey Black EABW CSSD 25 D3 Yellow Red EACL CSSD 25 D3 Grey Black EABW CSSD 25 D4 Yellow Red EACL CSSD 25 D4 Grey Black EABW CSSD 40 D3 Yellow Red EACL CSSD 40 D3 Grey Black EABW CSSD 40 D4 Yellow Red EACL CSSD 40 D4 Grey Black EABW CSSD 63 K3 Yellow Red EACL CSSD 63 K3 MRP Moulded Switches In Aluminium Alloy Enclosure Rating Amps Pole MRP 6 3 CSSD6D CSSD6D CSSD25D CSSD25D CSSD30D CSSD30D CSSD40D CSSD40D CSSD63K CSSD80D CSSD00D CSSD25D3 680 Toggle Switches With Toggle type operating knob CSSD in Open Execution Rating Amps Pole MRP 25 3 CSSD25C CSSD25C CSSD40C3 4 CSSD40C CSSD63C CSSD63C4 370 Please replace with ELCL or ELBL ELCL - Rotary handle colour: Red Rotary Knob with Yellow base. ELBL - Rotary handle colour: Black Rotary Knob with Grey base.

43 Switch Disconnector Switch Disconnectors (Moulded construction) Accessories Auxiliary Contacts For Switch Type Pole MRP NO + NC CSSD 25A-40A 3 CSSDZX NO + 2 NC CSSD 25A-40A 3 CSSDZX NO + NC CSSD 25A-40A 4 CSSDZX NO + 2 NC CSSD 25A-40A 4 CSSDZX NO + NC CSSD 63A 3 CSSDZX NO + 2 NC CSSD 63A 3 CSSDZX NO + NC CSSD 25A 3 CSSDZX NO + 2 NC CSSD 25A 3 CSSDZX NO + NC CSSD 63A-25A 4 CSSDZX NO + 2 NC CSSD 63A-25A 4 CSSDZX Spares Extended Terminals Rating (Amps) Pole MRP TPN ET ET Rotary Knob Handles For Switch Type MRP CSSD 25A-25A (Moulded-Red/Yellow) CSSDZX CSSD 25A-25A (Moulded-Black) CSSDZXBL Spare Handle Shaft For Switch Type MRP CSSD 25A-25A CSP5X70 30 Door Mounting Kit (for mounting Switch on door instead of base plate) For Switch Type MRP CSSD 25A-25A DMK 30 Note: Key & Castle Locks are available on request. Switch Disconnectors (Moulded construction) Accessories Auxiliary Contacts For Switch Type Pole MRP NO + NC CSSD 25A-60A (Compact) 3/4 CSSDZX NO + 2 NC CSSD 25A-60A (Compact) 3/4 CSSDZX NO + NC CSSD 200A-35A (Compact) 3/4 CSSDZX NO + 2 NC CSSD 200A-35A (Compact) 3/4 CSSDZX NO + NC CSSD 200A-800A 3/4 CSSDZX NO + 2 NC CSSD 200A-800A 3/4 CSSDZX NO + NC CSSD 000A-350A 3/4 CSSDZX NO + 2 NC CSSD 000A-350A 3/4 CSSDZX Key Interlocks (3 Locks - 2 Keys) For Switch Type MRP CSSD 25A-60A CSSDZW - 6 CSSD 200A-350A CSSDZW Castle Key Locks For Switch Type MRP CSSD 25A-60A CSSDZW CSSD 200A-350A CSSDZW - 4 Handle Mounting Kit (for independent mounting of O/E Switches) For Switch Type MRP CSSD 200A-35A (Compact Series) HMK-2 40 CSSD 200A-800A HMK-- 50 CSSD 000A-800A HMK Spares Switch Handles For Switch Type MRP CSSD 200A-800A (Moulded) CSWH 45 S2 80 CSSD 000A-800A (Metallic) CSWH 220 S2 030 CSSD 2500A-350A (Metallic) CSDA8 20 CSSD 25A-60A (Compact) (Moulded) CSWH 80 S6 CSSD 200A-35A (Compact) (Moulded) CSWH80 S8 470 Switch Handle Shaft CSSD 25A-60A (Compact) CAP6x65 CSSD 200A-35A (Compact) CSP8x CSSD 200A-800A CSP2x CSSD 2500A-350A CSP2x Switch Poles ( Price per Pole ) 25A (Compact) CSSD-SP-25DM 00 60A (Compact) CSSD-SP-60DM A (Compact) CSSD-SP-200DM A (Compact) CSSD-SP-250DM A (Compact) CSSD-SP-35DM A CSSD-SP400K A CSSD-SP630K A CSSD-SP800K A CSSD-SP000P A CSSD-SP250P A CSSD-SP600P A CSSD-SP800P Extended Terminals for Switch Disconnectors For Switch Type Pole MRP 25~60 (Compact) TPN ET P ET ~400 TPN ET P ET Notes: 'K' series from 000A to 350A in open execution is also available on special request for retrofit jobs only. For price, please contact nearest Branch Office.

44 Changeover Switch On Load Changeover Switches (Back to Back Type) LT Heavy Duty 4 Pole On Load Changeover Load Break Switch, 45V, 50Hz complete with handle assembly having Door Interlock and Padlocking arrangement. In Open Execution Rating (Amps) Type Pole MRP 63 NM 4 CSCS63NM4CO NM 4 CSCS00NM4CO NM 4 CSCS25NM4CO NM 4 CSCS60NM4CO NM 4 CSCS200NM4CO NM 4 CSCS250NM4CO DM 4 CSCS35DM4CO DM 4 CSCS400DM4CO K 4 CSCS630K4CO K 4 CSCS800K4CO P 4 CSCS000P4CO P 4 CSCS250P4CO P 4 CSCS600P4CO P 4 CSCS800P4CO P 4 CSCS2000P4CO P 4 CSCS2500P4CO P 4 CSCS350P4CO In Sheet Steel Enclosure Rating (Amps) Type Pole MRP 63 NM 4 E-CSCS63NM4CO NM 4 E-CSCS00NM4CO NM 4 E-CSCS25NM4CO NM 4 E-CSCS60NM4CO NM 4 E-CSCS200NM4CO NM 4 E-CSCS250NM4CO DM 4 E-CSCS35DM4CO DM 4 E-CSCS400DM4CO K 4 E-CSCS630K4CO K 4 E-CSCS800K4CO P 4 E-CSCS000P4CO P 4 E-CSCS250P4CO P 4 E-CSCS600P4CO P 4 E-CSCS800P4CO P 4 E-CSCS2000P4CO P 4 E-CSCS2500P4CO P 4 E-CSCS350P4CO Notes: 'K' series from 000A to 350A in open execution is also available on special request for retrofit jobs only. For price, please contact nearest Branch Office. On Load Changeover Switches (Back to Back DM Type - Available for retrofit jobs only.) Rating (Amps) Type Pole MRP 63 DM 4 CSCS63DM4CO DM 4 CSCS80DM4CO DM 4 CSCS00DM4CO DM 4 CSCS25DM4CO DM 4 CSCS60DM4CO DM 4 CSCS200DM4CO DM 4 CSCS250DM4CO 6820 Rating (Amps) Type Pole MRP 63 DM 4 E-CSCS63DM4CO DM 4 E-CSCS80DM4CO DM 4 E-CSCS00DM4CO DM 4 E-CSCS25DM4CO DM 4 E-CSCS60DM4CO DM 4 E-CSCS200DM4CO DM 4 E-CSCS250DM4CO Accessories Auxiliary Contacts for NM Type Changeover Description MRP NO +NC for 63~00A# CSCONM AUX NO +NC for 25~250A CSCONM2 AUX 0 2NO +2NC for for 25~250A CSCONM2 AUX Switch Handle Shaft for NM Type Changeover Rating (Amps) MRP 63~00A CSPNM 8X ~250A CSPNM2 8X0 295 # Factory fitted only. Direct handle Mounting Kit for NM Type Changeover Rating (Amps) MRP 63~00A CSCONM HMB ~250A CSCONM2 HMB 400 Handle Sub Assembly for NM Type Changeover Rating (Amps) MRP 63~00A CSCONM H 80 S ~250A CSCONM2 H 45 S8 630 Accessories for DM/K/P Type Changeover, please refer page 45 Switch Disconnector Fuse Changeover LT Switch Disconnector Fuse Changeover complete with Handle Assembly having Door Interlock and Padlocking arrangement without fuses. 4 Pole in Open Execution 4 Pole in Sheet Steel Enclosure Rating (Amps) MRP Recommended Fuse Links Type (IEC Size) BS Rating (Amps) MRP Recommended Fuse Links Type (IEC Size) BS 25 CSCF25B4CO 2430 CTF-25(B2) 60 CSCF60B4CO 3290 CTF-60(B2) 200 CSCF200B4CO CTF-200(B2) 250 CSCF250B4CO CTKF-250(B3) 35 CSCF35B4CO CTKF-35(B3) 400 CSCF400B4CO CTMF-400(B4) 630 CSCF630B4CO CTTM-630(C2) 800 CSCF800B4CO CTLM-800(C3) 25 E-CSCF25B4CO 5970 CTF-25(B2) 60 E-CSCF60B4CO 7470 CTF-60(B2) 200 E-CSCF200B4CO CTF-200(B2) 250 E-CSCF250B4CO CTKF-250(B3) 35 E-CSCF35B4CO CTKF-35(B3) 400 E-CSCF400B4CO CTMF-400(B4) 630 E-CSCF630B4CO CTTM-630(C2) 800 E-CSCF800B4CO CTLM-800(C3)

45 Bypass Switch Bypass Switches LT By Pass Switch complete with Handle Assembly having Door Interlock and Padlocking arrangement. In Open Execution Rating (Amps) Pole MRP 63 4 CSBS63DM CSBS80DM CSBS00DM CSBS25DM CSBS60DM CSBS200DM CSBS250DM CSBS35DM CSBS400K CSBS630K CSBS800K CSBS000P CSBS250P CSBS600P CSBS800P In Sheet Steel Enclosure Rating (Amps) Pole MRP 63 4 E-CSBS63DM E-CSBS80DM E-CSBS00DM E-CSBS25DM E-CSBS60DM E-CSBS200DM E-CSBS250DM E-CSBS35DM E-CSBS400K E-CSBS630K E-CSBS800K E-CSBS000P E-CSBS250P E-CSBS600P E-CSBS800P Notes: 'K' series from 000A to 350A in open execution is also available on special request for retrofit jobs only. For price, please contact nearest Branch Office. Bypass Switch application Table of Operation Handle Switch-I Switch-II Switch-IIl Remarks Position-I ON OFF ON Regulated Supply to Load Position-O OFF OFF OFF Position-II OFF ON OFF Accessories for Changeover -Type DM/K/P Auxiliary Contacts Contacts Configuration NO + NC NO + NC 2 NO + 2 NC 2 NO + 2 NC NO + NC 2NO + 2 NC Spare Handle For Switch Type CSCS/SBS 63A-60A Upper CSCF 25A-60A CSCS/SBS 63A-60A Lower CSCF 25A-60A CSCS/SBS 63A-60A Upper CSCF 25A-60A CSCS/SBS 63A-60A Lower CSCF 25A-60A CSCS/BS 200A-800A CSCF 200A-800A CSCS/BS 200A-800A CSCF 200A-800A No Supply, Load as well as Regulator Isolated form incoming source Direct Supply, Regulator By-passed & Isolated Qty./ Switch MRP CSCSZX-U 430 CSCSZX-L 430 CSCSZX3-U 850 CSCSZX3-L CSCSZX CSCSZX4 690 Notes : If changeovers switch is required with Auxiliary contacts, please order the same separately. Prices listed are for the pair of auxiliary contacts, if applicable. Rating (Amps) MRP CSCS/CSBS 63-35A/CSCF25-35A CCOH 45 S8 680 CSCS/CSBS 400A-800A/CSCF A CCOH 220 S2 886 Spare Poles ( Price per Pole ) Rating (Amps) Type MRP 63 CSCS/CSBS CSSD-SP-63DM CSCS/CSBS CSSD-SP-80DM CSCS/CSBS CSSD-SP-00DM CSCS/CSBS/CSCF CSSD-SP-25DM CSCS/CSBS/CSCF CSSD-SP-60DM CSCS/CSBS/CSCF CSSD-SP200DM CSCS/CSBS/CSCF CSSD-SP250DM CSCS/CSBS/CSCF CSSD-SP35DM CSCS/CSBS/CSCF CSCS-SP400K CSCS/CSBS/CSCF CSCS-SP630K CSCS/CSBS/CSCF CSCS-SP800K CSCS/CSBS CSCS-SP000P CSCS/CSBS CSCS-SP250P CSCS/CSBS CSCS-SP600P CSCS/CSBS CSCS-SP800P Notes: for one changeover of 4 pole, 8 Nos of sparepoles are requied. Spare Handle Shaft Type MRP CSCS 63-35A CSBS 63-35A CSCF25-35A CSP8X CSCS 400A-800A CSP2X CSCS 2000A-350A (Metallic) CSDA6 000 CSCS 2000A-350A CSBS 400A-800A CSCF 400A-800A CSP2X

46 SDF Changeover Switch Disconnector Fuse Changeover - Conventional Type (Side-by-Side) LT Heavy Duty 4 Pole Changeover Switch Disconnector Fuse unit comprising of two Switches, 32A - 800A, 45V, 50Hz mounted on common chasis complete with Mechanical Interlock and Handle Assembly having Door Interlock & Padlocking arrangements (without Fuses) CSSDF in Open Execution, 4 Pole Rating (Amps) DIN BIS MRP 32 CSSDF32D4CO CSSDF32B4CO CSSDF63D4CO CSSDF63B4CO 8890 Accessories Changeover Switches (CSSDF) Spare Handles For Switch Type MRP CSSDF 32A - 60A (Moulded) CCOH 80 S CSSDF00D4CO CSSDF00B4CO CSSDF25D4CO CSSDF25B4CO 6090 CSSDF 200A - 400A (Moulded) CCOH 220 S2 875 CSSDF 630A - 800A (Metallic) CSDA CSSDF60D4CO CSSDF60B4CO CSSDF200D4CO CSSDF200B4CO CSSDF250D4CO CSSDF250B4CO CSSDF35D4CO CSSDF35B4CO CSSDF400D4CO CSSDF400B4CO CSSDF630D4CO CSSDF630B4CO NA CSSDF800B4CO Load Break Changeover- Conventional Type (Side-by-Side) LT Heavy Duty 4 Pole Changeover Load Break Switch comprising of two Switches 25A - 350A, 45V, 50Hz mounted on common chasis complete with Mechanical Interlock and Handle Assembly having Door Interlock and Padlocking arrangements. CSSD in Open Execution, 4 Pole Rating (Amps) MRP 25 CSSD25D4CO CSSD40D4CO CSSD63D4CO CSSD25DM4CO CSSD200DM4CO CSSD250DM4CO CSSD400K4CO CSSD630K4CO CSSD800K4CO CSSD000P4CO CSSD250P4CO CSSD600P4CO CSSD800P4CO CSSD2500P4CO CSSD350P4CO Note:. Shorting Links / Busbars NOT provides with open execution in conventional type Changeover Switchses Enclosure Prices on request. 2. 'K' series from 000A to 350A in open execution is also available on special request for retrofit jobs only. For price, please contact nearest Branch Office. Off-load Changeover Switch Rating (Amps) Pole Rated Voltage MRP CSCSOF32CO V 460 CSCSOF63CO V 2860 CSCSOF32CO V 2450 CSCSOF63CO V 5000 CSCSOF00CO V 9900 CSCSOF200CO V 500 Operating Mechanism - For CSSDF Changeover Switches For Switch Type MRP CSSDF 32A-60A CSSDFZW 2730 CSSDF 200A-400A CSSDZW2/ 7670 CSSDF 630A-800A CSSDZW Accessories - Changeover Switch (CSSD) Spare Handles For Switch Type MRP CSSD 25A-25A (Moulded) CCOH 00 S6 490 CSSD 200A-800A (Moulded) CCOH 220 S2 875 CSSD 000A-350A (Metallic) CSDA6 000 Operating Mechanism For Switch Type MRP CSSD 25A - 40A CSSDZW CSSD 63A - 25A (DM type) CSSDZW6/ 2700 CSSD 200A - 400A (DM type) CSSDZWA 2700 CSSD 400A - 800A (K type) CSSDZW 5600 CSSD 000A - 350A (P type) CSSDZW Switch Fuse Unit: Rewirable Switch Fuse Unit: Rewirable with Side Handle Rating (Amps) Pole Rated Voltage MRP CSRW6PNS 6 SPN 240 V 475 CSRW32PNS 32 SPN 240 V 75 CSRW6P2S 6 DP 240 V 493 CSRW32P2S 32 DP 240 V 265 CSRW32P3NS 32 TPN 45V 890 CSRW63P3NS 63 TPN 45V 3930 CSRW00P3NS 00 TPN 45V 7450 CSRW200P3NS 200 TPN 45V 800 Switch Fuse Unit: Rewirable with Front Handle Rating (Amps) Pole Rated Voltage MRP CSRW32P3NF 32 TPN 45V 290 CSRW63P3NF 63 TPN 45V 4230 CSRW00P3NF 00 TPN 45V 7750 CSCSOF35CO V 9300 CSCSOF400CO V POR Off Load Changeover Rewirable

47 HRC Fuse HRC Fuses HRC Fuse Bases & Fuse Holders Low watt losses & low let thru energy HRC Fuse Links tested for 80kA at 45V / 500V, as per IEC 269 (Pt.& 2), complete with Fuse indicators DIN Type Fuse Links with Blade Contacts In A IEC Size MRP 6 CDFL006 0 CDFL000 6 CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL HRC Fuse Bases & Fuse Holders are tested for 80 ka at 45V / 500V, as per IS :3703 (Pt. 2 / Sec.) and IEC 269 (Pt.& 2) Fuse Bases for DIN Type Fuse Links (with ISI mark) In A IEC Size MRP CDFB CDFB CDFB CDFB NOTE: 3- Phase version available on request. Solid Links IEC Size MRP CDSL CDSL CDSL CDSL Fuse Holders (Fuse Fittings) for British Pattern Fuses Links Rating (Amps) IEC Size MRP CNS20H* 20 F 0 22 CSM32H* 32 A CSM63H* 63 A Low watt loss & let thru energy HRC Fuse Links tested for 80kA at 45V / 500V with ISI mark as per IS :3703 (Pt.2 / Sec.) and IEC 269 (Pt.& 2), complete with Fuse indicators DIN Type Fuse Links with Blade Contacts In A IEC Size MRP 6 OFAA00H OFAA00H OFAA00H OFAA00H POR 25 OFAA00H OFAA00H CDFL CDFL CDFL CDFL CDFL CDFL CDFL CDFL32 50 CDFL50 63 CDFL63 80 CDFL80 3 POR 00 CDFL00 25 CDFL25 60 CDFL60 POR 200 CDFL CDFL CDFL CDFL CDFL POR 200 CDFL CDFL CDFL CDFL CSM00H 00 A CSM00B 00 A * "ISI" marked Fuse Holders (Fuse Fittings) for Cylinderical HBC Fuse Links Rating (Amps) IEC Size MRP CHO32R 32 4 x CHC63R 63 4 x Fuse Puller MRP CDFH NOTE : All orders will be accepted only in standard packaging qty.

48 HRC Fuse British Pattern HRC Fuse Links Low watt loss & let thru energy HRC Fuse Links tested for 80kA at 45V / 500V, as per IEC 269 (Pt.& 2), complete with Fuse indicators CNS (Off Set) clip in Type Rating (Amps) IEC Size MRP CNS 2, 4, 6, 8,0,2&6 F CNS 20, 25 & 32 F Off Set TAG Type Rating (Amps) IEC Size MRP CNIT 2, 4, 6, 8, 0, 2 & 6 A CNIT 20, 25, & 32 A CTIA* 4, 6,0,6, 20, 25 & 32 A CTIS* 32, 35, 40, 50 & 63 A CTCP A4 6 CTCP A4 6 Central TAG (4 hole fixing ) Type Rating (Amps) IEC Size MRP CTCP A4 6 CTCP A4 6 CTCP A4 6 CTFP CTFP CTFP * "ISI" marked CTM C 800 CTM C CTTM C2 995 CTTM C2 CTTM C2 500 CTLM C3 730 CTLM C3 Central TAG (2 hole fixing) Type Rating (Amps) IEC Size MRP CTC B 6 CTLM C3 CTLM C3 Cylindrical HrC/Fuse Links 730 CTC B 6 CTC B 6 CTF B2 3 CTF B2 3 CTF B2 3 CTKF B3 CTKF B3 CTKF B3 CTMF B4 CTMF B Rating (Amps) IEC Size MRP CHF 2, 4, 6, 8 & 0 (4*5) CHF 6, 20 & 25 (4*5) 20 CHF 32 & 40 (4*5) 20 8 CHF 50 (4*5) CHF 63 (4*5) CGF 2, 4, 6, 8,0 & 6 (0*38) 20 CGF 20 & 25 (0*38) CGF 32 (0*38) 20 Rewirable Fuse Holder (Kit-Kat) Rating (Amps) Fuse Wire Size (Max.) MRP CSKTRW SWG 200 CSKTRW SWG 320 CSKTRW SWG 590 CSKTRW X 4SWG 90 3

49 MRP w.e.f. 23 rd April 202

50 MPCB Motor Protection Circuit Breaker Conforming IS : IEC Global certification TCMS-Model - Thermal Magnetic Adjustable thermal release Magnetic release 3 X Ie Max. Trip class 0 Ambient temperature compensation Phase failure protection Type / Frame 32AF 63AF 00AF Power Rating 3-PhMotors AC3-duty 45V, 50Hz Adjustable range (Amp) Breaking Capacity 45V, 50Hz MRP Breaking Capacity 45V, 50Hz Kw HP Standard Model/ Toggle Switch High Breaking Capacity / Rotary Handle ~ TCMS-32S~ TCMS-32H~ ~ TCMS-32S~ TCMS-32H~ ~ TCMS-32S~ TCMS-32H~ ~ TCMS-32S~ TCMS-32H~ ~ 00 TCMS-32S~ TCMS-32H~ ~.6 00 TCMS-32S~ TCMS-32H~ ~ TCMS-32S~ TCMS-32H~ ~4 00 TCMS-32S~ TCMS-32H~ ~6 00 TCMS-32S~ TCMS-32H~ ~8 00 TCMS-32S~ TCMS-32H~ ~0 50 TCMS-32S~ TCMS-32H~ ~3 50 TCMS-32S~ TCMS-32H~ ~7 20 TCMS-32S~ TCMS-32H~ ~22 5 TCMS-32S~ TCMS-32H~ ~26 5 TCMS-32S~ TCMS-32H~ ~32 5 TCMS-32S~ TCMS-32H~ ~40 50 TCMS-63H~ ~50 50 TCMS-63H~ ~63 50 TCMS-63H~ ~75 75 QTCMS-00H~ ~90 75 QTCMS-00H~ ~00 75 QTCMS-00H~ MRP Std. Pkg. (No's) TCMS-Model - Magnetic (Short circuit protection only) Without thermal release Magnetic release 3 X Ie Max. Frame Breaking Capacity at 45V, 50Hz Power Rating 3-Ph Motors AC3 duty 45V, 50Hz KW HP Rated Operational Current Ie (A) MRP TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ AF TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-32HI~ TCMS-63HI~ AF TCMS-63HI~ TCMS-63HI~ QTCMS-00HI~ AF QTCMS-00HI~ QTCMS-00HI~ Non Stockable item

51 MPCB - Accessories Accessories for MPCBs Description Configuration Model MRP (No's) Auxiliary switch for front mounting Auxiliary switch for front side mounting on the left Any trip alarm switch for side mounting on the left NO+NC TFX 485 2NC TFX NO TFX NO+NC TLX 585 2NC TLX NO TLX NO+NC TLA 750 2NC TLA NO TLA Magnetic trip alarm switch for side mounting on the left TLAM 775 Shunt release for side mounting on the right Undervoltage release for side mounting on the right Undervoltage release with switch for side mounting on the right 0~27V50Hz TRS0~27V50Hz ~230V50Hz TRS220~230V50Hz ~440V50Hz TRS45~440V50Hz 240 0~27V50Hz TRU0~27V50Hz ~230V50Hz TRU220~230V50Hz ~440V50Hz TRU45~440V50Hz 240 0~27V50Hz TRUX0~27V50Hz ~230V50Hz TRUX220~230V50Hz ~440V50Hz TRUX45~440V50Hz 275 Insulation Barrier (for TCMS-00H/00HI only) TIB Adaptor kit for MPCB + Mini Contactors Busbar TCMS-32S+TCM06-6 TDA-6SA 375 TCMS-32S+TPM06-6 TDA-6SD 375 TCMS-32H/32HI+TCM06-6 TDA-6HA 375 TCMS-32H/32HI+TPM06-6 TDA-6HD Point 3 Point* MPCB Enclosure (IP 65 Category) For TCMS-32H/HI EPH32-65S 060 Extension Shaft 5mm TCMS-32H/HI MEH32-5 TCMS-63H/HI MEH Extended Handle (Door Mounting with TCMS-00H/HI MEH00-5 Door Interlock, Defeat Interlock & Padlock) Extension Shaft 35mm TCMS-32H/HI MEH32-35 TCMS-63H/HI MEH TCMS-00H/HI MEH00-35 PB322 PB632 PB323 PB Non Stockable item

52 Mini Contactor Mini Contactors Conforming IS/IEC & IEC Global certification Control Relays - 0 Amps Rated Current (Ith) Contact Configuration With AC Coil With DC Coil MRP MRP 2 NO+2NC TCA2-M22 TCA3-M22 0 Please specify Coil Voltage. 3 NO+NC TCA2-M3 TCA3-M3 4 NO TCA2-M TCA3-M40 NO + 3NC TCA2-M3 TCA3-M3 4NC TCA2-M04 TCA3-M Power Contactors - 3 Pole AC Duty A 20 AC3 45V Long Life With AC Coil Auxiliary Contacts KW HP A MRP Auxiliary Contacts NO - TC-M060 NO - TP-M NC TC-M060 - NC TP-M060 NO - TC-M090 NO - TP-M NC TC-M090 - NC TP-M090 0 NO - TC-M20 NO - TP-M NC TC-M20 - NC TP-M20 NO - TC-M60 NO - TP-M NC TC-M60 - NC TP-M60 With DC Coil MRP Please specify Coil Voltage. Coil Voltage Codes for Mini Contactors & Control Relays Contactor Voltage AC B E F M N DC BD ED FD MD - Overload Relays for Mini Contactors - Direct Mounting Relay Range (Amps) MRP Independent Mounting Kit TR2 - M0.4A TR2 - M0.2A TR2 - M0.33A TR2 - M0.52A TR2 - M0.82A -.6 TR2 - M.3A TR2 - M2.A TR2 - M3.3A 020 TA7-M0964 MRP TR2 - M5A 5-8 TR2 - M6.5A 6-9 TR2 - M7.5A 7-0 TR2 - M8.5A 9-3 TR2 - MA 2-6 TR2 - M4A 5 Non Stockable item

53 Mini Contactor Accessories for Mini Contactors Add-On-Block Contact Configuration MRP Front 2 NO TA-M20 (No's) Mounted NO+ NC TA-M 95 2 NC TA-M02 4 NO TA-M40 3 NO+ NC TA-M3 2 NO+2 NC TA-M22 NO+3 NC TA-M3 4 NC TA-M04 Side NC TA8-M0 Mounted NO TA8-M Mechanical Interlocks for Horizontally Mounted AC Use For Contactor DC MRP (No's) TC-MS06 TC-MS09 TC-MS2 TC-MS6 TP-MS06 TP-MS09 TP-MS2 TP-MS6 TA9-M Electronic Timer Description Delay Time Voltage MRP Front Mounting Electronic Timer ON Delay 0.~30sec AC/DC TA2-M/ N OFF Delay 0.~30sec 24~48V TA2-M/ F ON Delay 0.~30sec AC TA3-M/ 2N OFF Delay 0.~30sec 00~220V TA3-M/ 2F 080 Coil Suppressor Description Voltage MRP AC 24~ 48V TA9-M980/ AC 60~ 27V TA9-M980/2 AC 200~ 240V TA9-M980/3 Varistor DC 2~ 24V TA9-M980/4 335 DC 30 ~ 72V TA9-M980/5 DC 00 ~ 27 V TA9-M980/6 DC 200~ 250 V TA9-M980/7 Non Stockable item

54

55 Contactor robusta 2 Contactor Conforming IS/IEC & IEC Contactor AC Duty (A) AC3 45V Long life Auxilary Contacts MRP KW HP A NO+NC TCD07n NO+NC TCD09n NO+NC TCD2n NO+NC TCD8n NO+NC TCD25n NO+NC TCD32n NO+NC TCD38n 4420 Overload Relay fixing attachment Use for Contactor MRP TCD07-8 TA7D TCD25-38 TA7D Spare Top Housing for 3P Contactors For Contactor MRP Coil Surge Suppressor Description Voltage Ratings MRP Varistor (AC/DC) Clip on mounting 2~55V 50/60Hz TAD4VE 56~36V 50/60Hz TAD4VF 37~277V 50/60Hz TAD4VU 278~575V 50/60Hz TAD4VN TC-D07 TA5-D07 Spare AC Coils for Contactor TC-D09 TA5-D TC-D2 TA5-D2 TC-D8 TA5-D8 830 TC-D25 TA5-D Use for Contactor MRP TCD07 TCD09 TC-D32 TA5-D TCD2 TC-D38 TA5-D Mechanical Interlocks - Horizontal Mounted Use of Contactor MRP TCD07~TCD38 LA9-D TCD8 TCD25 TCD32 TCD38 TX-D3n 435 Thermal Overload Relay Relay setting range (A) Standard power ratings of 3-Phase Motors 50/60Hz, AC3 Category HP kw Suitable for Contactor Rating (Amps) MRP Independent Mounting Kit TR2DM TR2DM TA7D0964 MRP `90 Note: n n robusta Thermal Overload Relay TR2D0930~TR2D25322 can be mounted directly on robusta 2 Contactor with additional fixing attachment TA7D0765 (Contactor TCD07~8) or TA7D2565 (Contactor TCD25~38). robusta 2 Thermal Overload Relay reference TR2DM32353 ~TR2DM38355 can be mounted directly on robusta 2 Contactor without any additional fixing attachment. robusta2 Contactor Coils Contactor TC-D / TXD3 24V 48V 0V 220V 240V 45V 50 Hz B5 E5 F5 M5 U5 N5 How to order: i) Select applicable Coil Voltage required for Contactor. ii) Complete the code by replacing the nfom above. iii) For common accessories please refer page no. 6

56 Contactor robusta Power Contactors Conforming IS/IEC & IEC Control Relays - 0 Amps Rated Current(Ie) AC5 at 240V (Amps) Contact Configuration With AC Coil With DC Coil MRP MRP 2 NO + 2NC TCA2-DN22 TCA3-DN NO + NC TCA2-DN TCA3-DN3 4 NO TCA2-DN40 TCA3-DN To specify Coil Voltage, please refer page no. 59 Power Contactors 3 Pole : Rating 9A ~ 95A AC Duty A AC3 45 V Long Life With AC Coil With DC Coil Auxiliary Auxiliary Contacts Contacts KW HP A MRP MRP NO - TC-D090 NO - TP-D NC TC-D090 - NC TP-D090 NO - TC-D20 NO - TP-D NC TC-D20 - NC TP-D20 NO - TC-D80 NO - TP-D NC TC-D80 - NC TP-D80 NO - TC-D220 NO - TP-D NC TC-D220 - NC TP-D220 NO - TC-D250 NO - TP-D NC TC-D250 - NC TP-D250 NO - TC-D320 NO - TP-D NC TC-D320 - NC TP-D320 NO - TC-D380 NO - TP-D NC TC-D380 - NC TP-D NO NC TC-D NO NC TP-D NO NC TC-D NO NC TP-D NO NC TC-D NO NC TP-D NO NC TC-D NO NC TP-D NO NC TC-D NO NC TP-D NO NC TC-D NO NC TP-D NO NC TC-D To specify Coil Voltage, please refer page no. 59 Power Contactors 3 Pole 4NC : Rating 9A ~ 25A AC Duty A 25 AC3 45 V Long Life With AC Coil kw HP A MRP TC-D TC-D TC-D To specify Coil Voltage, please refer page no. 59

57 Contactor robusta Power Contactors Conforming IS/IEC & IEC Power Contactors With Dust Cover 3 Pole: Rating 5A ~ 800A AC Duty A AC3 45 V Long Life With AC Coil With DC Coil kw HP A MRP MRP LCFDP5A 2200 LCFDP5A LCFDP50A 6200 LCFDP50A LCFDP85A LCFDP85A LCFDP200A LCFDP200A LCFDP225A LCFDP225A LCFDP265A LCFDP265A LCFDP300A LCFDP300A LCFDP330A LCFDP330A LCFDP400A LCFDP400A LCFDP460A LCFDP500A LCFDP500A LCFDP580A LCFDP630A 8225 LCFDP630A QLCFDP780A QLCFDP780A QLCFDP800A To specify Coil Voltage, please refer page no. 59 Power Contactors with dust cover 2 Pole variants available on requests Power Contactors with dust cover rating 5~800A are supplied factory assembled complete with No-Volt Coil and auxiliary contact block 2NO+2NC. Hoisting Power Contactors with dust cover 3 Pole : Rating 5A ~ 630A AC3 45 V Long Life With AC Coil AC Duty A kw HP A MRP LCFDP5HCA LCFDP50HCA LCFDP85HCA LCFDP225HCA LCFDP265HCA LCFDP330HCA LCFDP400HCA LCFDP500HCA LCFDP630HCA To specify Coil Voltage, please refer page no. 59 Telecom Contactors 4Pole Rating AC 25 A~50A AC Duty A Main Pole Configuration With AC Coil MRP 25 4 NO TCDT254Ne NO TCDT324Ne NO TCDT404Ne NO TCDT504Ne 2340 Non Stockable item

58 Contactor Power Contactors 4 Pole : Rating AC 25A ~ 25A AC Duty A Main Pole Configuration With AC Coil With DC Coil MRP MRP 25 4NO -- TC-D TP-D NO 2NC QTC-D QTP-D NO -- QTC-D Not Available NO -- TC-D TP-D NO 2NC QTC-D QTP-D NO -- TC-D TP-D NO 2NC QTC-D QTP-D NO -- TC-D Not Available NO 2NC QTC-D Not Available - 4NO -- TC-D TP-D NO 2NC QTC-D QTP-D NO -- TC-D TP-D NO 2NC QTC-D QTP-D NO -- TC-D TP-D NO 2NC QTC-D QTP-D To specify Coil Voltage, please refer page no. 59 Power Contactors with dust cover 4 Pole : Rating AC 200A ~ 600A AC Duty A Main Pole Configuration With AC Coil With DC Coil Refrerence MRP Refrerence MRP NO LCFDP LCFDP NO LCFDP LCFDP NO LCFDP LCFDP NO LCFDP LCFDP NO QLCFDP QLCFDP NO QLCFDP QLCFDP NO QLCFDP QLCFDP NO QLCFDP QLCFDP NO QLCFDP QLCFDP NO QLCFDP QLCFDP To specify Coil Voltage, please refer page no. 59, 62 4 Pole Power Contactors with dust cover rating AC 200~600A are supplied factory assembled complete with No-Volt Coil and auxilary contact block 2NO+2NC. Non Stockable item

59 Contactor Capacitor Duty Contactors 3 Pole, AC kvar Rating Auxiliary Contacts Refrerence MRP 7 NO+NC 2NC TC-D07K TC-D07K NO+NC 2NC TC-D0K TC-D0K NO+NC 2NC TC-D2K TC-D2K NO+NC 2NC NO+NC 2NC TC-D6K TC-D6K02 TC-D20K TC-D20K NO+NC 2NC TC-D25K TC-D25K NO+2NC TC-D33K NO+2NC TC-D40K NO+2NC TCD50K NO+2NC TC-D60K2 00 robusta Contactors Coils AC Coil Voltage Codes for Contactors 9A~95A & Control Relays DC Coil Voltage Codes for Contactors 9A~95A & Control Relays Contactor Voltage Contactor Voltage TCA2-DN / TC-D Hz B5 E5 F5 M5 C5W* U5 N5 50/60Hz B7 E7 F7 M7 - U7 N7 Non-Standard coil Extra ` 00/- per contactor * Available from CR~38A Contactor only. AC Coil Voltage robusta Capacitor Duty Contactors Contactor Voltage TC-D**K Hz B5 F5 M5 C5W* U5 N5 50/60Hz B7 F7 M7 - U7 N7 * Available upto 25kVAR only. AC Coil for 4 Pole Telecom Contactor Contactor Voltage TC-DT**Ne Hz P C5W M N All coils codes applicable for extra wide band coils. How to order: I) Select applicable Coil Voltage required for Contactor. ii) Complete the code by replacing the iii) To order additional Auxiliary Block, Timers and other accessories, please refer page 6 Non-Standard coil available on request, Extra MRP@ ` 500 each per Contactor rating 5#780A TCA3-DN/ TP-D Normal Coil BD ED SD FD MD Wide band Coil# BW EW - FW - # Wide band Coil available in 50 Hz only AC Coil Voltage Codes for Contactors 5A~780A Voltage Contactor LCFDP5~225 50Hz F5 M5 U5 N5 LCFDP265~780 50/60Hz F7 M7 U7 N7 Not Available for LCFDP780 DC Coil Voltage Codes for Contactors 5A~780A Voltage Contactor 24# LCFDP BD ED FD MD # Not available for LCFDP630 & LCFDP780 Coil Voltage Codes for Contactor 800A Voltage Contactor 0/27 220/ /400 LC-FDP - AC FW* MW* QW** LC-FDP-DC FW MW QW *With rectifier DRTE4U **With rectifier DRTE4S Non Stockable item

60 Overload Relay robusta Overload Relay Thermal Overload Relays Direct Mounting Relay Setting Range (Amps) Standard Power Rating for 3 Ph. Motor at 45V HP kw Refrerence Suitable for Contactor Rating (Amps) MRP Indepen-dent Mounting Kit Direct Mounting 0.0 ~ 0.6 * * TR2-D ~ 0.25 * * TR2-D ~ 0.40 * * TR2-D ~ 0.63 * * TR2-D ~ TR2-D ~ TR2-D ~ TR2-D093X ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D236X ~ TR2-D ~ TR2-D832X ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D ~ TR2-D Independent Mounting 65 ~ LR-F05 80 ~ LR-F25 00 ~ LR-F ~ LR-F ~ LR-F ~ QLR-F ~ QLR-F ~ QLR-F ~ QLR-F ~ QLR-F ~ QLR-F TA7-D0964 MRP `90 TA7-D3264 ` 275 TA7-D4064 ` 920 Thermal Overload Relays Protective Shroud for LR-F05~630 Relay Type MRP LR-F(M)05 LR-F(M)25 LA9-F LR-F60 LR-F200 LR-F250 LR-F35 LA9-F LR-F400 LR-F500 LR-F630 LA9-F LR-F800 Non Stockable item Heavy Duty Overload Relays Independent Mounting Relay Setting Range (Amps) MRP TR6 - F TR6 - F TR6 - F TR6 - F TR6 - F TR6 - F QTR6 - F QTR6 - F QTR6 - F QTR6 - F QTR6 - F QTR6 - F QTR6 - F400

61 Contactor Accessories for robusta Contactors Add-On Block for Contactor Rating 9~800A Mechanical Interlocks - Horizontal Mounted Contact Configuration MRP NO TA-DN0* 5 0 NC TA-DN0 2 NO TA-DN20 NO+ NC TA-DN Front Mounted 2 NC TA-DN02 4 NO TA-DN40 3 NO+ NC TA-DN3 2 NO+2 NC TA-DN NO+3 NC TA-DN3 4 NC TA-DN04 Contact Configuration AC DC TC-D09 TP-D09 TC-D2 TP-D2 TC-D8 TP-D8 TC-D25 TP-D25 TC-D32 TP-D32 TC-D40 TP-D40 TC-D50 TP-D50 TC-D65 TP-D65 TC-D70 TP-D70 TC-D80 TP-D80 TC-D95 - MRP LA9-D LA9-D LA9-D Side Mounted NO+ NC TA8-DN** 2 NO TA8-DN20 * Suitable for robusta Contactor rating 25~95A only. ** Suitable for robusta Contactor rating 9~95A only. Spare AC Coils Control Relay & Contactor 9~95A Use for Contactor AC MRP TCA2-DN TC-D09 TC-D2 TX-D Pneumatic Timer Block - Front Mounted Contact Configuration MRP Std. Pkg. ON delay NO+ NC TA2-DT s ON delay NO+ NC TA2-DT s ON delay NO+ NC TA2-DT s OFF delay NO+ NC TA3-DR s OFF delay NO+ NC TA3-DR s OFF delay NO+ NC TA3-DR s Star Delta NO+ NC TA2-DS2...30s TC-D8 TC-D25 TC-D32 TC-D40 TC-D50 TC-D63 TC-D80 TC-D95 TX-D TX-D Coil Surge Suppressor for Contactor 9~95A Description Voltage Ratings MRP Varistor (AC/DC) Clip-on mounting RC Circuit (AC) Clip-on mounting 24~48VAC/DC TA9AMOV980E 0~240V AC/DC TA9AMOV980U 24~48V AC TA9RC980E 0~240V AC TA9RC980U 380~440V AC TA9RC980N Std. Pkg Spare DC Coils Control Relay & Contactor 9~80A Electrical & Mechanical Interlocks - Horizontal Mounted Use for Contactor DC MRP TCA3 - DN Use for Contactor AC DC * MRP TP - D09 TP - D2 TP - D8 TP - D25 TP - D32 TP - D40 TX4-D2 TX5-D2 580 TX4-D4 TX5-D4 75 TC-D09 TC-D2 TC-D8 TC-D25 TC-D32 TC-D40 TC-D50 TP-D09 TP-D2 TP-D8 TP-D25 TP-D32 TP-D40 TP-D50 ELA9-D ELA9-D TP - D50 TX4-D40 TX5-D TC-D65 TP-D65 TP - D65 TP - D80 TX4-D80 TX5-D TC-D80 TP-D80 TC-D95 - ELA9-D Complete the code for Spare Coil by indicating the Coil Voltage required after the reference *Please refer page no. 59 for Coil Voltage available Non Stockable item

62 Contactor Accessories Spare AC Coils for Hoisting Power Contactor Contactor 0V 220V 240V 45V MRP LC-FDP5HCA LC-FDP50HCA LC-FDP85HCA LX9FF0V LX9FF220V LX9FF240V LC-FDP225HCA LX9FG0V LX9FG220V LX9FG240V QLC-FDP265HCA LX9FH02V LX9FH2202V LX9FH2402V QLC-FDP330HCA QLC-FDP400HCA LX9FJ925 LX9FJ93 LX9FJ932 LX9FJ QLC-FDP500HCA LX9FK925 LX9FK93 LX9FK932 LX9FK QLC-FDP630HCA LX9FL924 LX9FL930 LX9FL93 LX9FL NOTE: The above Coil includes rectifier price. Standard Packing No. Spare AC Coils for Contactors Rating 5~800A Contactor 0V 220V 240V 45V MRP LC-FDP5 LC-FDP50 LC-FDP85 LXFF-0V LXFF-220V LXFF-240V LXFF-45V 900 LC-FDP200 LC-FDP225 LC-FDP265A LXFG-0V LXFG-220V LXFG-240V LXFG-45V 3500 LC-FDP300A LXFH-02V LXFH-2202V LXFH-2402V LXFH-452V 3950 LC-FDP330A LC-FDP400A LXFJ-0V LXFJ-220V LXFJ-240V LXFJ-45V 6090 LC-FDP500A LXFK-0V LXFK-220V LXFK-240V LXFK-45V 3500 LC-FDP630A LXFL-0V LXFL-220V LXFL-240V LXFL-45V 4300 LC-FDP780A LXFX-0V LXFX-220V LXFX-240V LXFX-45V LC-FDP800A LX4F8FW LX4F8MW LX4F8MW LX4F8QW* 5500 AC Coils will be suitable for 50Hz only. *Available in 380/400V only NOTE: The above Coil includes rectifier price. Std. Packing Nos. Mechanical Interlocks for Contactor 5~630A Vertically / Horizontally Mounted Contactor MRP Horizontally Mounted LC-FDP5A LC-FDP50A LC-FDP85A LA9-FF LC-FDP200A LC-FDP225A LC-FDP265A LA9-FG LC-FDP300A LC-FDP330A LC-FDP400A LC-FDP500A LC-FDP5004/LC-F630A QLA9-FJ970 QLA9-FL Vertically Mounted LC-FDP5A LC-FDP50A LC-FDP85A LA9-FF4F 2750 LC-FDP200A LC-FDP225A LC-FDP265A LA9-FG4G 2805 LC-FDP300A LA9-FH4H LC-FDP330A LC-FDP400A QLA9-FJ4J 3355 LC-FDP500A QLA9-FK4K LC-FDP5004/LC-F630A QLA9-FL4L LC-FDP780A QLA9-FX Non Stockable item Spare DC Coils for Contactors Rating 5~800A Contactor 0V 220V 24V 485V MRP LC-FDP5 LC-FDP50 LC-FDP85 LX4FF-0V LX4FF-220V LX4FF-24V LX4FF-48V 6500 LC-FDP225 LC-FDP265A LX4FG-0V LX4FG-220V LX4FG-24V LX4FG-48V 8500 LC-FDP330A LX4FH-0V LX4FH-220V LX4FH-24V LX4FH-48V 0700 QLC-FDP400A LX4FJ-0V LX4FJ-220V Not Available LX4FJ-48V 7000 QLC-FDP500A LX4FK-0V LX4FK-220V Not Available LX4FK-48V 7000 QLC-FDP630A LX4FL-0V LX4FL-220V Not Available LX4FL-48V 7500 QLC-FDP780A l LX4FX-220V l l 8000 QLC-FDP800A LX4F8FW LX4F8MW - LX4F8QW* 8500 NOTE: The above Coil includes rectifier price. Standard Packing No. lcontact Branch Office for product code. *Available in 380/400V only. Spare Top Housing for 3P/4P Contactors For Control Relay MRP Contactor AC DC For 3 Pole TCA2-DN40, TCA3-DN40 TA5-DN40 TA5-DN40 DC TCA2-DN3, TCA3-DN3 TA5-DN3 TA5-DN3 DC TCA2-DN22, TCA3-DN22 TA5-DN22 TA5-DN22 DC TC-D090, TP-D090 TA5-D090 TA5-D090 DC 730 TC-D090, TP-D090 TA5-D090 TA5-D090 DC TC-D20, TP-D20 TA5-D20 TA5-D20 DC TC-D20, TP-D20 TA5-D20 TA5-D20 DC TC-D80, TP-D80 TA5-D80 TA5-D80 DC 830 TC-D80, TP-D80 TA5-D80 TA5-D80 DC TC-D220, TP-D220 TA5-D220 TA5-D220 DC 020 TC-D220, TP-D220 TA5-D220 TA5-D220 DC TC-D250, TP-D250 TA5-D250 TA5-D250 DC 070 TC-D250, TP-D250 TA5-D250 TA5-D250 DC TC-D320, TP-D320 TA5-D320 TA5-D320 DC 2055 TC-D320, TP-D320 TA5-D320 TA5-D320 DC TC-D380, TP-D380 TA5-D380 TA5-D380 DC 305 TC-D380, TP-D380 TA5-D380 TA5-D380 DC TC-D40, TP-D40 TA5-D40 TA5-D40 DC 320 TC-D50, TP-D50 TA5-D50 TA5-D50 DC 3875 TC-D65, TP-D65 TA5-D65 TA5-D65 DC 525 TC-D70, TP-D70 TA5-D70 TA5-D65 DC 5700 TC-D80, TP-D80 TA5-D80 TA5-D80 DC 6345 TC-D95 TA5-D For 4 Pole TC-D09004, TP-D09004 TA5-D09004 TA5-D09004DC 90 TC-D09008, TP-D09008 TA5-D09008 TA5-D09008DC 05 TC-D2004, TP-D2004 TA5-D2004 TA5-D2004DC 040 TC-D2008, TP-D2008 TA5-D2008 TA5-D2008DC 20 TC-D25004, TP-D25004 TA5-D25004 TA5-D25004DC 620 TC-D25008, TP-D25008 TA5-D25008 TA5-D25008DC 870 TC-D40004, TP-D40004 TA5-D40004 TA5-D40004DC 350 TC-D40008, TP-D40008 TA5-D40008 TA5-D40008DC 4495 TC-D65004, TP-D65004 TA5-D65004 TA5-D65004DC 5990 TC-D65008, TP-D65008 TA5-D65008 TA5-D65008DC 7020 TC-D80004, TP-D80004 TA5-D80004 TA5-D80004DC 765

63 Contactor Accessories Spare Main Contact for 3P Contactors rating 5~800A Contactor MRP LC-FDP5A/HCA LA5-FF43 (F5) 6335 LC-FDP50A/HCA LA5-FF43 (F50) 6850 LC-FDP85A/HCA LA5-FG43 (F85) 350 LC-FDP200A/HCA LA5-FG43 (F200) 5450 LC-FDP225A/HCA LA5-FG43 (F225) 730 Spare Arc Chamber 3P Contactor MRP LC-FDP5A LA5-F LC-FDP50A LA5-F LC-FDP85A LA5-F LC-FDP200A LA5-F LC-FDP225A LA5-F LC-FDP265A/HCA LA5-FH43 (F265) 8450 LC-FDP300A/HCA LA5-FH43 (F300) 9270 LC-FDP265A LA5-F LC-FDP300A LA5-F LC-FDP330A/HCA LA5-F (F330) 2070 LC-FDP330A LA5-F LC-FDP400A/HCA LA5-F (F400) LC-FDP400A LA5-F LC-FDP500A/HCA LA5-F (F500) LC-FDP500A LA5-F LC-FDP630A/HCA LA5-F (F630) LC-FDP630A LA5-F LC-FDP780A/HCA LA5F78080(F7804)* LC-FDP780A LA5-F78050* 6950 LC-FDP800A/HCA LA5F800803(F800) Spare Arc Chamber 4P Spare Main Contact Sets for 4P Power Contactors rating 5~780A Contactor MRP LC-FDP54A LA5-FF44 (F54) 7940 LC-FDP504A LA5-FF44 (F504) 0965 LC-FDP854A LA5FG44(F854) 9340 Contactor MRP LC-FDP54A LA5-F LC-FDP5A LA5-F LC-FDP50A LA5-F LC-FDP85A LA5-F LC-FDP225A LA5-F LC-FDP2254A LA5FG44(F2254) 2025 LC-FDP265A LA5-F LC-FDP2654A LA5-FH44 (F2654) 2540 LC-FDP3304A LA5-F (F3304) 260 LC-FDP4004A LA5-F (F4004) LC-FDP5004A LA5-F (F5004) LC-FDP6304A LA5-F (F6304) LC-FDP7804A LA5-F78080 (F780)** LC-FDP330A LA5-F LC-FDP400A LA5-F LC-FDP500A LA5-F LC-FDP630A LA5-F LC-FDP780A LA5-F78050* 7350 LC-FDP800A LA5-F # Main Contacts set per pole includes (2 Fixed Contacts & Moving Contact, 2 Deflectors, Backplate, Fixing Screws and Washers). * Main Contacts are for one pole only. (Set of two) Order 3 Nos for 3 pole Contactors & 4 Nos for 4 pole Contactors. ** Set of Main Contacts provided is set of 2 blocks for one pole. # Main Contacts set per pole includes (2 Fixed Contacts & Moving Contact, 2 Deflectors, Backplate, Fixing Screws and Washers). * Main Contacts are for one pole only. (Set of two) Order 3 Nos for 3 pole Contactors & 4 Nos for 4 pole Contactors. ** Set of Main Contacts provided is set of 2 blocks for one pole. Electronic Timer Description MRP Star Delta Timer, Range 0 ~ 30 Sec,250~440V AC Tcet030sd45vac 60 Non Stockable item

64 D Range Contactor D Range Contactors & Overload Relays Control Relays 0 Amps Contact Arrangement 2 NO+ 2 NC CA2-DN229 A60 3 NO+ NC CA2-DN39 A60 4 NO CA2-DN40 A60 Please specify Coil Voltage. Power Contactors - 3 Pole, AC AC Duty A AC3 45V Long Life kw HP A A.C. MRP Auxiliary Contacts 830 MRP NO - LC-D093 A60 - NC LC-D099 A NO - LC-D23 A60 - NC LC-D29 A NO - LC-D73 A60 - NC LC-D79 A NO - LC-D253 A60 - NC LC-D259 A NO - LC-D323 A60 - NC LC-D329 A NO NC LC-D403 A NO NC LC-D503 A NO NC LC-D633 A NO NC LC-D803 A Thermal Overload Relays Type LR - Direct Mounting Relay Setting Range A Std. Power Rating for 3 Phase Motor at 45V HP kw MRP * * LR-D * * LR-D * * LR-D * * LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D LR-D Independent Mounting Kit LA7-D0964 MRP` 75 LA7-D3264 MRP `260 LA7-D4054 MRP ` 370 * There is no standard power rating for these motors. Select the overload relay in relation to the full load current. AC Coil Voltage Codes for D Range Contactors (Standard) Contactor Voltage * 220* 240* 45* LC-D B E F M U N * Wide band Coils Thermal Overload Relays Type LR - Independent Mounting Relay Setting Range A Std. Power Rating for 3 Phase Motor at 45V MRP HP kw 66.0 to LR-D AC Coil Voltage Codes for D Range Contactors (Non - Standard) Voltage Contactor LC-D D UW Q For Non-Standard Coil Voltage, please add ` 00/- in the list price. AC Coil Voltage Codes for Definite Purpose Contactors Voltage 24VAC 0VAC 240VAC 50Hz B5 G5 U5 60Hz B6 G6 U6 Definite Purpose Contactor FLA Resistive AMP Rating MRP Single Pole (Without Shunt) TCDP25* TCDP30* TCDP40* 530 Single Pole (With Shunt) TCDP25S* TCDP30S* TCDP40S* 600 Two Pole TCDP202* TCDP302* TCDP402* TCDP203* 775 Non Stockable item

65 Accessories - D Range Contactor ACCESSORIES for D Range Contactors Spares Add-on-Blocks for D Range Contactors Additional Instantaneous Aux.Contact Blocks Overlapping Aux. Contacts Contactor MRP Front Mounted Front Mounted 2 NO LA-D20 NO+ NC LA-D 2 NC LA-D02 4 NO LA-D40 3 NO+ NC LA-D3 2 NO+2 NC LA-D22 * NO+3 NC LA-D3 4 NC LA-D04 * This Auxiliary Contact can be used with Contactors. # Consisting of NO+ NC make before break contacts NO+2 NC LA-D# D Range Mechanical Interlocks Horizontally Mounted Use for Contactor AC MRP Spare AC Coil Voltage for D Range Contactors AC ( Standard ) Use for Contactor AC (Standard) CA2-DN LC-D09 LC-D2 LC-D7 LC-D25 LC-D32 LC-D40 LC-D50** LC-D63 LC-D80** MRP LX-D LX-D LX-D40 65 Please specify Coil Voltage by indicating the Coil Voltage required. ** Spare Moulded Base for these Coils has Product code LA7-D40 and unit price is ` 35 LC-D09 LC-D2 LC-D7 LC-D25 LC-D32 LC-D40 LC-D50 LC-D63 LA9-D LA9-D LC-D80 LA9-D Coil Suppressor Description For mounting across coil of contactor upto 80Amp, with RC network suitble for < 250VAC & <400V AC Mechanical Latching Blocks Description for Contractors / Control Relays Type MRP LA9-D MRP Spare Top Housing 3P For Control Relay/ Contactor AC MRP CA2-DN40 LA5-DN40 CA2-DN39 LA5-DN39 CA2-DN229 LA5-DN LC-D093 LA5-D093 LC-D099 LA5-D099 LC-D23 LA5-D LC-D29 LA5-D29 LC-D73 LA5-D LC-D79 LA5-D79 LC-D253 LA5-D LC-D259 LA5-D259 LC-D323 LA5-D LC-D329 LA5-D329 LC-D403 LA5-D LC-D503 LA5-D LC-D633 LA5-D LC-D803 LA5-D CA2-DN LC-D09, LC-D2 LC-D7, LC-D25,LC-D32 LA6-DK Replace by voltage code AC Not suitable for DC control relay & DC Contactor AC Coil Voltage Codes (Standard) For Mechanical Voltage Latching Block /440 LA6-DK0 B E F M U Q N DC Coil Voltage Codes (Standard) For Mechanical Voltage Latching Block LA6-DK0 B E EN F M Add-on Starting Switch Description NO starting Switch suitable for direct mounting on Control Relays & Contactors MRP LA9-D Non Stockable item

66 2 & 4 Pole Contactor Contactors - 4 Pole, AC Contactors - 2 Pole, AC AC3, 45V kw HP A Main Poles Configuration MRP AC Duty AC3 220V AC kw HP A MRP NO TCDX AC2-D NO TCDX AC2-D NO TCDX AC2-D Please specify Coil Voltage. AC Coil Voltage Codes (Standard) for 2 Pole Contactors AC Coil Voltage Codes (Standard) for 4 Pole Contactors Contactor 4P Voltage ~ ~450 TC-DX204/254 F M Q N Spare Coil for 4 Pole Contactors Coil Voltage MRP TXD20 0/220/90~400/250~ Spare Contact Kit for 4 Pole Contactor Description MRP TA5DX204 20A Contact Kit, 4-Pole 700 TA5DX254 25A Contact Kit, 4-Pole 50 TA5DX404 40A Contact Kit, 4-Pole 730 Add-on-Blocks for 4 Pole Contactors Contact Description MRP Configuration Front mounted Aux. contact Block NO+ NC TA-DNA 60 2 Mechanical Interlock for 4 Pole Contactors Description MRP Horizontal Mounted LA9-D Mechanical Interlock ELA9-D Contactor 2P Spare Coil for 2Pole Contactors Coil Voltage MRP AXD2 MU AXD2 M AXD2 QN AXD2 N 220/240V, 50Hz 220V, 50Hz 380/45V, 50Hz 45V, 50Hz Spare Contact Kit for 2 Pole Contactor Description MRP AC5D202 20A Contact Kit, 2-Pole 350 AC5D252 25A Contact Kit, 2-Pole 700 AC5D402 40A Contact Kit, 2-Pole 940 AC5D20 20A Contact Kit, NO+NC 355 Add-on-Blocks for 2 Pole Contactors Description Front mounted Aux. contact Block Contact Configuration 2 NO NO+ NC 2 NC LA-D20A LA-DA LA-D02A Voltage 220* 220/240* 380 / 45* AC2-D2/D3/D4 M5W MU QN * Wide band Coils Please specify Coil Voltage MRP Thermal Overload Relays 3 Pole type LR3D - Direct Mounting Relay Setting Range (A) MRP.60~2.50 LR3D09307 Thermal Overload Relays 2 Pole type LR7D - Direct Mounting Relay Setting Range (A) LR7-D0920 MRP Independent Mounting Kit 2.50~4.00 LR3D ~6.00 LR3D LR7-D LR7-D ~8.00 LR3D ~0.0 LR3D LR7-D226X 3-8 LR7-D622 LA7D0964 MRP `75 9.0~4.0 LR3D236X ~8.0 LR3D LR7-D622X 8-25 LR7-D ~22.0 LR3D632X 8.0~25.0 LR3D LR7-D

67 Industrial Plugs & Sockets IEC Series IP 44 & IP 67 Versions DESCRIPTION Rating (Amp) Protection Degree 3 PIN, 2P+E 240V AC 5 PIN, 3P+N+E 45V AC Code MRP h Code MRP h Panel Mounting Socket - Splash Proof 6 CS CS IP CS CS CS CS Panel Mounting Socket -Water Tight 32 IP 67 CS CS CS CS Surface Mounting Socket - Splash Proof 6 CS CS IP CS CS CS CS Surface Mounting Socket - Water Tight 32 IP 67 CS CS CS CS Plugs - Splash Proof 6 CS CS IP CS CS CS CS Plugs - Water Tight IP CS CS CS CS Surface Mounting Interlocked Switched Socket Outlet - Horizontal 6 CS66004(H) CS6609(H) IP CS6605(H) CS66020(H) Surface Mounting Interlocked Switched Socket Outlet - Vertical 6 CS CS IP CS CS Connector - Splash Proof 6 CS CS IP CS CS Note: Plugs & Sockets 3 PIN, 2P+E 240V AC are in Blue color, 5 PIN, 3P+N+E 45V AC are in Red color AC Distribution Box with Socket DESCRIPTION Rating (Amp) Protection Degree Code MRP h 6A 3P 240V CS AC Distribution Box (Includes Socket & Plug) 32A 3P 240V CS IP 40 32A 5P 45V CS A 5P 45V CS

68

69 Push Button Push Buttons: 22.5mm Without Contact Elements Push Button Actuators with Carrier - Non-Illuminated Std. Description MRP Pkg. (No.s) RCP2-BA RCP2-BA2 Push Spring Return Push RCP2-BA3 Button RCP2-BA RCP2-BA5 RCP2-BA6 Flush Spring Return Push RCP2BA33 Button with contact RCP2BA RCP2-BL RCP2-BL2 Projecting Push Button RCP2-BL RCP2-BL4 RCP2-BL5 RCP2-BL6 RCP2-BC2 RCP2-BC3 Mushroom Head Push Button, Spring Return RCP2-BC RCP2-BC5 RCP2-BC6 RCP2-BC2 RCP2-BC3 Mushroom Head Push Button, Spring Return with contact RCP2-BC RCP2-BC5 RCP2-BC6 Mushroom Head Push 40mm RCP2BS Button Stay Put (press to 60mm lock, turn to release) RCP2BS Mushroom Head Push Button, Push to Stay & Key to release Push Button Stay Put 30mm (Press to Lock turn to release RCP2BS RCP2BS Push Button Actuators with Carrier & Contact Element-Non-Illuminated Flush Spring Return Push Button with NO Block Push Button with NC Block Projecting Head Push Button with NO Block Projecting PB with NC Block RCP2-BA RCP2-BA2 RCP2-BA3 RCP2-BA5 RCP2-BA6 RCP2-BA4 RCP2-BA42 RCP2-BL RCP2-BL2 RCP2-BL3 RCP2-BL5 RCP2-BL6 RCP2-BL Product Picture Push Button Actuators - Illuminated Flush without Series Resistor Illuminated Actuator, Flush (With BA9 Filament Bulb) 2V, 24V, 48V, 0V AC / DC Illuminated Actuator, Flush (With BA9 Neon Bulb) 220V, 380V, 45V AC / DC RCP2-BW36p RCP2-BW336p RCP2-BW346p RCP2-BW356p RCP2-BW366p 28 0 RCP2-BW376p RCP2-WN336p RCP2-WN346p RCP2-WN356p + Push Button Actuators - Illuminated Flush with Series Resistor Description MRP Illuminated Actuator, Flush (with BA9S Filament Bulb, 30V) 220V AC/DC RCP2BW37p RCP2-BW337p RCP2-BW347p RCP2-BW357p RCP2-BW367p RCP2-BW377p Std. Pkg. (No.s) 38 0 Description MRP Std. Pkg. (No.s) LED Type Push Button Actuators - Illuminated Flush Flush Illuminated with RCP2-BWL337p Integral Circuit LED suitable RCP2-BWL347p for operationg at 240V V, 0V, 48V, 24V & 2V RCP2-BWL357p Flush Illuminated With Integral Circuit LED suitable for operationg at 240V RCP2-BWL367p V, 0V, 48V, 24V & 2V Push Button Actuator-Illuminated Projecting without Series Resistor RCP2-BW6p Illuminated Actuator, Flush (With BA9 Filament Bulb) RCP2-BW36p 2V, 24V, 48V, 0V AC / RCP2-BW46p DC RCP2-BW56p RCP2-BW66p RCP2-BW76p Illuminated Actuator, Flush (With BA9 Neon Bulb) 220V, RCP2-BWN36p 380V, 45V AC / DC RCP2-BWN46p RCP2-BWN56p 22 0 Product Picture Colour Code for Actuator / Lens Colour Code Colour of Actuator White Black Green Red Yellow Blue - Colour of Lens White - Green Red Amber Blue Clear Product Picture Push Button Actuator-Illuminated Projecting without Series Resistor Illuminated Actuator, Projecting (with BA9S Filament Bulb, 30V) 220V AC / DC RCP2-BW7p RCP2-BW37p RCP2-BW47p RCP2-BW57p RCP2-BW67p RCP2-BW77p 28 0 LED Type Push Button Actuators - Illuminated Projecting Type of voltage AC/DC to be specified Projecting Illuminated Actuator, with integral LED, suitable for operating at common Voltage AC/DC 0V, 48V, 24V &2V Also available at operational Voltage 240V AC, 220V DC 0V AC, 0V DC RCP2-BWL7p RCP2-BWL37p RCP2-BWL47p RCP2-BWL57p RCP2-BWL77p RCP2-BWL87p 68 0 RCP2-BWL67p padd Voltage Code, v Operating voltage available in 240V AC, 0V & 220V DC

70 Push Button Push Buttons: 22.5mm Without Contact Elements Selector Switch Actuators with Carrier Description MRP 2-Position Selector Switch (stay put) 3-Position Selector Switch,centre 'OFF' (stay put) 2-Position Selector Switch with extra long knob (stay put) 3-Position Selector Switch, with extra long knob centre 'OFF'(stay put) 3-Position Selector Switch (Spring Return) RCP2-BD2 RCP2-BD3 RCP2-BJ2 RCP2-BJ3 Std. Pkg. (No.s) RCP2-BDR Position Selector Switch extra RCP2-BJR long knob (Spring Return) Selector Switch Actuators with Carrier & Contact Element 2-Position Selector Switch (stay RCP2-BD2 206 put) with NO Block 2-Position Selector Switch, centre 'OFF' (stay put) with NO+NC Block 3-Position Selector Switch, centre 'OFF' (stay put) with NO+NC Block Key Actuators with Carrier 2-Position Key Switch, Key removable in unactuated position 2-Position Key Switch, Key removable in both position 2-Position Key Switch, Key removable in 'Right Hand' position 2-Position (Spring Return) Key Switch,Key, removable in 'Left Hand'position 3-Position Key Switch, Key removable in centre 'OFF' position 3-Position Key Switch, Key removable in all position RCP2-BD25 RCP2-BD35 RCP2-BG2 RCP2-BG4 RCP2-BG02 RCP2-BG6 RCP2-BG3 RCP2-BG0 3-Position Key Switch, Key removable in 'Left Hand & Right RCP2-BG5 Hand'position 3-Position Key Switch, Key removable in 'Left Hand' position 3-Position Key Switch, Key removable in 'Right Hand' position RCP2-BG9 RCP2-BG Product Picture + Push Buttons Extended Range Description MRP Std. Pkg. (No.s) Intermittent Sounding Flashing Buzzer 5 ~ 20 ma, sound level RB2-KS* 80 db.24v, 48V, 0V AC/DC V AC (* Add Voltage code) Pilot Lamps with Transformer RCP2-BV4p RCP2-BV43p Pilot Lamp (with BA9S Filament RCP2-BV44p Bulb) for Input Voltage:240V AC and output Voltage: 6VAC RCP2-BV45p RCP2-BV46p RCP2-BV47p RCP2-BV3p RCP2-BV33p Pilot Lamp (with BA9S Filament RCP2-BV34p Bulb) for input Voltage:0V AC and output Voltage: 6V AC RCP2-BV35p RCP2-BV36p RCP2-BV37p Pilot Lamps with Series Resistor RCP2-BV7p RCP2-BV73p Pilot Lamp (with BA9S Filament RCP2-BV74p Bulb 30V) 220V AC / DC 0 RCP2-BV75p RCP2-BV76p RCP2-BV77p Pilot Lamps with Series Resistor & Diode RCP2 BVD7p RCP2-BVD73p RCP2-BVD74p 7 0 RCP2-BVD75p RCP2-BVD76p RCP2-BVD77p Contact Elements - NO/NC Contact Element NO RB2- BE Contact Element NC RB2- BE-02 LED Type Pilot Lamp Type of voltage AC / DC to be specified RCP2-BVL73p Pilot Light with integral circuit RCP2-BVL74p LED, suitable for operating at common Voltage RCP2-BVL75p AC/DC 0V, 48V, 24V &2V 45 RCP2-BVL77p 0 Also available at operational RCP2-BWL37p Voltage 240V AC, 220V DC RCP2-BWL387p 0V AC, 0V DC RCP2-BWL367p 295 Product Picture Push Buttons Extended Range Reset Extended Actuator RCB2AL8R Pushbutton - Round Type Reset Extended Actuator Pushbutton - Hex Type Plastic Adopter for 30 mm hole to 22.5 mm. Metal Adopter for 30 mm hole to 22.5 mm Recess (Guarded) Push button - Plastic RCB2AL8H RP2-BZ4M RB2-BZ4M RP2-BA6 RP2-BA26 RP2-BA36 RP2-BA46 RP2-BA56 RP2-BA How to Order: Actuators, Contact Elements, Lens Assemblies can also be ordered separately or in combination, as required. Voltage Code for Pilot Lamps Voltage 2V 24V 48V 0V 220V 240V 380V 45V DC JD BD ED FD MD - QD ND AC JA BA EA FA MA UA QA NA Note: Please mention supply voltage of Pilot Lamps, Pilot Light Body Assemblies and Illuminated Push Buttons with product reference while ordering.

71 Push Button Push Buttons: 22.5mm Metallic Range (Without Contact Elements) Push Button Actuators with Carrier - Non-Illuminated Std. Description MRP Pkg. (No.s) RCB2-BA RCB2-BA2 Flush Spring Return RCB2-BA3 Push Button RCB2-BA RCB2-BA5 RCB2-BA6 RCB2-BL RCB2-BL2 Projecting Push Button RCB2-BL3 RCB2-BL RCB2-BL5 RCB2-BL6 RCB2-BP2 RCB2-BP3 Booted Push Button RCB2-BP RCB2-BP5 RCB2-BP6 RCB2-BC2 RCB2-BC3 Mushroom Head Push Button, Spring Return RCB2-BC4 90 RCB2-BC5 RCB2-BC6 Mushroom Head Push Button Stay Put (press to lock, turn to release) Mushroom Head Push Button, Push to Stay & Pull to release Mushroom Head Key Switch, StayPut, Key removable in both positions (press to lock and key to release) Push Button Stay Put (press to lock, turn to release) RCB2-BS RCB2-BS RCB2-BT RCB2-BSI RCB2-BS Push Button Actuators with Carrier & Contact Element-Non-Illuminated RCB2-BA RCB2-BA2 Flush Spring Return Push Button with NO Block RCB2-BA3 RCB2-BA5 RCB2-BA6 RCB2-BA Push Button with NC Block RCB2-BA42 Push Button with 2NO Block RCB2-BA RCB2-BL RCB2-BL2 Projecting Head Push Button RCB2-BL3 with NO Block 02 0 RCB2-BL5 Projecting PB with NC Block Mushroom Head Push Button Stay Put (press to lock, turn to release) with NC Block RCB2-BL6 RCB2-BL42 Mushroom Head Actuators - Illuminated Mushroom head push button illuminated (with BA9S Filament Bulb, 30V) 220V AC/DC - 2 position Momentary - 2 position Maintained RCB2-BS RCB2-BS RCB2-BW437 RCB2-BW447 RCB2-BW637 RCB2-BW Product Picture + Push Button Actuators-Illuminated Flush without Series Resistor Description MRP Illuminated Actuator, Flush (with BA9S Filament Bulb) 2V, 24V, 48V, 0V AC/DC Illuminated Actuator, Flush (with BA9S Neon Bulb) 220V, 380V, 45V AC/DC RCB2-BW36p RCB2-BW336p RCB2-BW346p RCB2-BW356p RCB2-BW366p RCB2-BW376sp RCB2-BWN336p RCB2-BWN346p Std. Pkg. (No.s) 40 0 RCB2-BWN356p Push Button Actuators-Illuminated Flush without Series Resistor Illuminated Actuator, Flush (with BA9S Filament Bulb, 30V) 220V AC/DC RCB2-BW37p RCB2-BW337p RCB2-BW347p RCB2-BW357p RCB2-BW367p 45 0 Product Picture RCB2-BW377p LED Type Push Button Actuators - Illuminated Flush Flush Illuminated Actuator, RCB2-BWL337p with integral circuit LED, RCB2-BWL347p suitable for operating at RCB2-BWL357p common voltage AC/DC 80 0 RCB2-BWL37p 220V, 0V, 48V, 24V & 2V Also available at operational RCB2-BWL377p voltage 240V AC, 220VDC, RCB2-BWL387p 0V AC, 0V DC RCB2-BWL367p Push Button Actuators - Illuminated Projecting without Series Resistor RCB2-BW6p Illuminated Actuator, Projecting (with BA9S Filament Bulb) 2V, 24V, 48V, 0V AC / DC Illuminated Actuator, Projecting (with BA9S Neon Bulb) 220V, 380V, 45V AC / DC RCB2-BW36p RCB2-BW46p RCB2-BW56p RCB2-BW66p RCB2-BW76p RCB2-BWN36p RCB2-BWN46p RCB2-BWN56p Push Button Actuators - Illuminated Projecting with Series Resistor Illuminated Actuator, Projecting (with BA9S Filament Bulb,30V) 220V AC / DC RCB2-BW7p RCB2-BW37p RCB2-BW47p RCB2-BW57p RCB2-BW67p RCB2-BW77p LED Type Push Button Actuators - Illuminated Projecting Type of voltage AC/DC to be specified Projecting Illuminated Actuator, with integral circuit LED, suitable for operating at 240V v, 220V v, 0V, 48V, 24V & 2V Projecting Illuminated Actuator, with integral circuit LED, suitable for operating at 240V v, 220V v, 0V, 48V, 24V & 2V RCB2-BWL37p RCB2-BWL47p RCB2-BWL57p 80 0 RCB2-BWL67p Double Push Button Actuators - Illuminated Flush without Series Resistor Illuminated Double Push Button, Flush Green & Red Knob marked I&O respectively (with BA9S Neon Bulb) 220V, 380V, 45V AC / DC RCB2-BWN96p 90 8 padd Voltage Code v Operating Voltage available in 240V AC & 220V DC

72 Push Button Push Buttons: 22.5mm Metallic Range (Without Contact Elements) Description MRP Push Button Actuators with Carrier - Non-Illuminated Std. Pkg. (No.s) Double Push Button,Flush Green & Red Knob marked I&O respectively RCB2-BA Selector Switch Actuators with Carrier 2-Position Selector Switch (stay put) 3-Position Selector Switch, centre 'OFF' (stay put) RCB2-BD2 RCB2-BD3 70 Product Picture RCB2-BJ2 2-Position Selector Switch with extra long knob (stay put) 3-Position Selector 75 Switch, with extra long knob RCB2-BJ3 centre 'OFF' (stay put) 0 2-Position Selector Switch RCB2-BDR2 (Spring Return) 95 3-Position Selector Switch (Spring Return) RCB2-BDR3 2-Position Selector Switch extra long knob (Spring RCB2-BJR2 Return) Position Selector Switch extra long knob (Spring RCB2-BJR3 Return) Selector Switch Actuators with Carrier & Contact Element 2-Position Selector Switch (stay put) with NO Block RCB2-BD Position Selector Switch, centre 'OFF' (stay put) with RCB2-BD25 NO+NC Block Position Selector Switch, centre 'OFF' (stay put) with RCB2-BD35 NO+NC Block Selector Switch Actuators - Illuminated with series resistor 2-Position Illuminated RCB2-BK237p Selector Switch (with BA9S Filament Bulb 30V) suitable RCB2-BK247p for operation at 220V AC / DC RCB2-BK257p Position Illuminated RCB2-BK337p Selector Switch (with BA9S Filament Bulb 30V) suitable RCB2-BK347p for operation at 220V AC / DC RCB2-BK357p Selector Switch Actuators-IIIuminated with integral circuit LED available on request Selector Switch Actuators - Illuminated without series resistor 3-Position Illuminated RCB2-BK336p Selector Switch (with BA9S Filament Bulb) 2V, 24V, RCB2-BK346p V, 0V AC/DC, 220V DC, 240V AC RCB2-BK356p + Description MRP Key Actuators with Carrier 2-Position Key Switch, Key removable in unactuated RCB2-BG2 position 2-Position Key Switch, Key removable in both position 2-Position Key Switch, Key removable in 'Right Hand' position 3-Position Key Switch, Key removable in centre 'OFF' position 3-Position Key Switch, Key removable in all position 3-Position Key Switch, Key removable in 'Left Hand & Right Hand ' position 3-Position Key Switch, Key removable in 'Left Hand' position 3-Position Key Switch, Key removable in 'Right Hand' position RCB2-BG4 RCB2-BG02 RCB2-BG3 RCB2-BG0 RCB2-BG5 RCB2-BG9 RCB2-BG09 3-Position (Spring Return) Key Switch, Key removable in RCB2-BG7 'Center' position Key Actuators with Carrier & Contact element 2-Position Key Switch with NO Block,Key removable in RCB2-BG2 unactuated position 2-Position Key Switch with NO Block, Key removable in both position RCB2-BG4 3-Position Key Switchwith NO+NC Block key removable in centre 'OFF' RCB2-BG3 position 3-Position Key Switch with NO+NC Block key removable in all position Contact Elements - NO/NC Contact Element NO Contact Element NC RCB2-BG04 RB2- BE-0 RB2- BE Std. Pkg. (No.s) Product Picture How to Order: Actuators, Contact Elements, Lens Assemblies can also be ordered separately or in combination, as required. Colour Code for Actuator / Lens Colour Code Colour of Actuator Colour of Lens White White Black - Green Green Red Red Yellow Amber Blue Blue + - Clear 2-Position Illuminated Selector Switch (with LED Bulb) suitable for operation at 2V, 24V, 48V, 0V AC/DC, 220V DC, 240V AC 3-Position Illuminated Selector Switch (with LED Bulb) suitable for operation at 2V, 24V, 48V, 0V AC/DC, 220V DC, 240V AC RCB2-BKL237p RCB2-BKL247p RCB2-BKL257p RCB2-BKL337p RCB2-BKL347p RCB2-BKL357p

73 Push Button Pilot Lamps: 22.5mm Metallic Range LED Type Pilot Lamp - Type of voltage AC / DC to be specified Description MRP Std. Pkg. (No.s) RCB2-BVL73p Pilot Light with integral circuit LED, suitable for operating at common voltage AC/DC 0V, 48V, 24V & 2V Also available at operational voltage 240V AC, 220V DC, 0V AC, 0V DC RCB2-BVL74p RCB2-BVL75p RCB-BVL77p RCB2-BVL78p RCB2-BVL76p Pilot Lamps with Transformer RCB2-BV4p RCB2-BV43p Pilot Lamp (with BA9S Filament RCB2-BV44p Bulb) for Input Voltage 240V AC and output Voltage 6V AC RCB2-BV45p RCB2-BV46p RCB2-BV47p RCB2-BV3p Product Picture Push Button Powder Coated Actuators with Carrier Description MRP Flush Spring Return Push Button powder coated Projecting Push Button RCB2-BA7 RCB2-BA27 RCB2-BA37 RCB2-BA47 RCB2-BA57 RCB2-BA67 RCB2-BL7 RCB2-BL27 RCB2-BL37 RCB2-BL47 RCB2-BL57 Std. Pkg. (No.s) RCB2-BL67 Integrated LED Pilot Lamp - Type of voltage AC/DC to be specified RCB7-IVL73p Product Picture RCB2-BV33p Pilot Lamp (with BA9S Filament RCB2-BV34p Bulb) for Input Voltage 0V AC and output Voltage 6V AC RCB2-BV35p RCB2-BV36p RCB2-BV37p Pilot Lamps with Series Resistor Pilot Lamp (with BA9S Filament bulb 30V) 220V AC / DC RCB2-BV7p RCB2-BV73p RCB2-BV74p RCB2-BV75p RCB2-BV76p RCB2-BV77p Pilot Lamps with Series Resistor & Diode Pilot Lamp (with BA9S Filament Bulb 30V) 240V AC RCB2-BVD7 RCB2-BVD73p RCB2-BVD74p RCB2-BVD75p RCB2-BVD76p RCB2-BVD77p Integral LED pilot Lamp suitable for operating at common voltage AC/DC 0V, 48V, 24V & 2V Also available at operational voltage 240V AC, 220V DC, 0V AC, 0V DC Wide range: 2V~240V AC/DC RCB7-IVL74p RCB7-IVL75p RCB7-IVL77p RCB7-IVL78p RCB7-IVL76p RCB7-IVL7p RCB7-IVL73p RCB7-IVL74p RCB7-IVL75p RCB7-IVL77p RCB7-IVL78p RCB7-IVL76p RCB7-IVL7p Voltage Code for Pilot Lamps Voltage Code 2V 24V 48V 0V 220V 240V 380V 45V AC JA BA EA FA MA UA QA NA DC JD BD ED FD MD - QD ND Note: Please mention supply voltage of Pilot Lamps, Pilot Light Body Assemblies and Illuminated Push Buttons with product reference while ordering.

74 Push Button Accessories Metallic Range (For Push Buttons & Pilot Lamps : 22.5mm) Operating Heads Without Contact Block and Carrier Description MRP Pilot Lamp Head Flush Push Button Projecting Push Button Mushroom Spring Return Mushroom Stay Put Mushroom illuminated - 2 position Momentary - 2 position Maintained Booted Push Button RB2-BV0 Std. Pkg. (No.s) RB2-BV03 RB2-BV RB2-BV05 RB2-BV06 RB2-BV07 RB2-BA RB2-BA2 RB2-BA3 RB2-BA RB2-BA5 RB2-BA6 RB2-BL RB2-BL2 RB2-BL RB2-BL4 RB2-BL5 RB2-BL6 RB2-BC2 RB2-BC3 RB2-BC4 85 RB2-BC5 RB2-BC6 RB2-BS RB2-BS RB2-BS RCB2-BW43 RCB2-BW44 RCB2-BW64 RCB2-BW63 RB2-BP2 RB2-BP3 RB2-BP4 RB2-BP5 RB2-BP Double Headed without Light RB2-BA Product Picture Operating Heads LED, Neon Pilot Lamp / Push Button Without Contact Block and Carrier Description RB2-BVLO3 RB2-BVLO4 LED Pilot Lamp Head RB2-BVLO5 RB2-BVLO6 RB2-BWL33 RB2-BWL34 LED Illuminating Flush Push Button RB2-BWL35 RB2-BWL36 RB2-BWL3 LED Illuminating Projecting RB2-BWL4 Push Button RB2-BWL5 RB2-BWL6 MRP Std. Pkg. (No.s) Product Picture Operating Heads LED, Neon Pilot Lamp / Push Button Without Contact Block and Carrier Description Selector 2-Position, Stay Put Selector 2-Position, Stay Put Selector 2- Position, Spring Return Selector 2-Position, Stay Put Selector 3-Position, Stay Put (Centre OFF) Selector 3-Position, Stay Put (Centre OFF) Selector 3-Position, Spring Return (Centre OFF) Selector 3-Position, Stay Put Key Selector 2 -Position, Stay Put Key Selector 2-Position, Stay Put Operating Handle MRP RB2-BD2 Standard 55 RB2-BJ2 Long 70 RB2-BDR2 Standard 55 RB2-BJR2 Long 70 RB2-BD3 Standard 55 RB2-BJ3 Long 70 RB2-BDR3 Standard 55 RB2-BJR3 Long 70 RB2-BG2 RB2-BG4 Key removable in L.H. position Key removable in both positions 230 Std. Pkg. (No.s) 0 Product Picture Double Headed Push Button with Light Illuminated Flush Push Button Illuminated Projecting Push Button RB2-BW9 0 0 RB2-BW33 RB2-BW34 RB2-BW RB2-BW36 RB2-BW37 RB2-BW3 RB2-BW4 RB2-BW Key Selector 2-Position, Stay Put Key Selector 2-Position, Spring Return Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put RB2-BG02 RB2-BG6 RB2-BG3 RB2-BG0 RB2-BG5 RB2-BG9 Key removable in R. H. position Key removable in L.H. position Key removable in centre position Key removable inall positions Key removable in L.. H. & R. H. position Key removable in L. H. position Illuminated Selector 2-Position Stay Put Illuminated Selector 3-Position Stay Put RB2-BW6 RB2-BW7 RB2-BK23 RB2-BK24 RB2-BK25 RB2-BK33 RB2-BK34 RB2-BK Key Selector 3-Position, Stay Put RB2-BG09 Key Selector 3-Position, Both Side Spring Return RB2-BG7 Mushroom Head RB2-BS4 with Key Stay Put Key removable in R. H. position Key removable in Centre position Key removable in both positions

75 Push Button Accessories Metallic Range (For Push Buttons & Pilot Lamps : 22.5mm) Body Assemblies with Contact Blocks, Screw & Captive Clamp Connection Description For Actuators,Push Buttons,Selectors & Key Switches RB2-BZ0 RB2-BZ02 RB2-BZ03 RB2-BZ04 RB2-BZ05 Contact Type NO NC NO+NO NC+NC NO+NC MRP Description MRP Filament Bulb (BA9S) 30V, 48V, 24V, 2V & 6V (2.6W max.) Neon Bulb (BA9S) 45V, 380V, 220V Set of Lens (one inner and one outer) for Pilot Lamp Head Lens for LED & Neon Type Pilot Lamp (w/o inner lens) Set of Lens (one inner and one outer) for Illuminating Actuator Lens for Illuminating LED & Neon actuator (w/o inner lens) Silicon Cap suitable for, - Booted Push Button - Push Buttons Flush - Push Buttons Illuminated Adopter for assembly of f30.5 mm in f22.5 mm Legend Plate with inscription (On, Off, Start, Stop, Slow, Fast, Forward, Reverse, Up, Down, Open, Close, Auto, Auto-o- Hand, Auto-Hand, Reset, Inch.) Body / Carrier with mounting screws (passivated) for making different assemblies RL-CF RL-CN RB2-BV00* 25 RB2-BVL00* 23 RB2-BW00* 25 RB2-BWL00* 25 RB2BP00 25 RC-S RC-L 32 Std. Pkg. (No.s) Std. Pkg. (No.s) RB2-BZ4 3 0 RB2-BYN 20 0 RB2-B* Yellow legend (PVC) f60mm RB2-PY Emergency Stop f90mm RB2-PY Product Picture Product Picture How to Order :. Actuators, switch elements, lens assemblies can be ordered separately or in combination. 2. Basic type designation for actuators is "RB2-B". Numerical colour code is added as a suffix to indicate the colour of the actuator or lens. Remove "*" and put numerical code as indicated below: Colour Code Colour of Actuator White Black Green Red Yellow Blue - Colour of Lens White - Green Red Amber Blue Clear 3. Different suffixes are assigned for flush, projecting, selector actuators etc. 4. The type designation for contact element is '' for NO and '2' for NC. 5. Basic type designation for legend plates is "RB2-BY". To complete code with type of inscription please remove "**" and put numerical code as indicated below. Standard Text Standard Text MRP (No's.) Start 2303 Stop 2304 Forward 2305 Reverse 2306 Up 2307 Down 2308 On 23 Off 232 Open 233 Close 234 Auto 235 Hand Reset 2323 Inch 232 Slow 2327 Fast 2328 Auto - Hand 2364 Auto-O-Hand 2385 Hand-O-Auto 2387 Important : ) Ordered quantities should be in multiple of standard packing. 2) Illuminated Push Buttons & Pilot Lamps will be supplied with bulb only. 3) N in product code stands for Neon Bulb. Control Stations (Assembled) Complete Control Stations - Start and Stop Functions Plastic, Spring Return Making Description Scheme Colour on legend MRP Flush Push Button Flush Push Button Latching Push Button Mushroom Head Key Switch 2 Flush Push Button 2 Flush Push Button NO 3 NC 4 NC NC NO+NC NO+NC 4 4 I START O STOP STOP STOP 3 I 4 O RC P 02 RC P 03 RC P 2 RC P 4 RC PBS542 RC PYBS542 RC PBS42 RC PYBS RC 2P START RC 2P STOP Complete Control Stations Directional/Movement Control Functions Plastic, Spring Return Marking Description Scheme Colour on legend 2 Flush Push Button 3 Flush Push Button NO + NO NO + NC + NO RC2P222 2 Up Down RC2P222A RC2P223 2 Right Left RC2P223A Open Close Forward Reverse Forward Stop Reverse Up Stop Down Right Stop Left Open Stop Close RC2P24 RC 2P 222B RC3P3 RC3P32 RC3P33 RC3P34 RC3P324 RC3P334 MRP Control Stations for Customer Assembly Empty Enclosure, Plastic Description Number MRP of Ways Top Base Yellow RC - PY RC - P 300 Bone Jet 2 RC - 2P 325 Grey Black 3 RC - 3P RC - 4P 425 Product Picture Product Picture Product Picture * Empty Enclosure's are available without contact blocks and push buttons and can be assembled with the accessories / spare parts as per specified requirements.

76 Push Button Control Stations (Assembled) Complete Control Stations - Start and Stop Functions Metal, Spring Return Description Flush Push Button Flush Push Button Latching Push Button Mushroom Head Key Switch 2 Flush Push Button 2 Flush Push Button Scheme Colour NO 3 NC 4 NC NC NO+NC NO+NC Marking on legend I START O STOP RC M 02 RC M 03 RC M 2 RC M 4 MRP STOP RC MBS STOP I O START STOP RC MBS RC 2M 23 RC 2M Complete Control Stations Directional/Movement Control Functions Metal, Spring Return Marking Description Scheme Colour on legend MRP 2 Flush Push Button 3 Flush Push Button NO + NO NO + NC + NO Up-Down RC 2M 222 RC 2M 222A Right-Left RC 2M 223A Open-Close RC 2M 24 Forward- Reverse Forward Stop Reverse Up Stop Down Right Stop Left Open Stop Close Control Stations for Customer Assembly Empty Enclosure, Metal Description Top Base Smoke Grey Dark Grey Number of Ways RC 2M 223 RC 2M 222B RC 3M 3 RC 3M 32 RC 3M 33 RC 3M 34 RC 3M 324 RC 3M MRP RC - M RC - 2M RC - 3M RC - 4M* 680 Product Picture Product Picture Product Picture * Empty Enclosure's are available without contact blocks and push buttons and can be assembled with the accessories / spare parts as per specified requirements. Operating Head for Control Stations For Customer assembly Plastic Operating Heads without contact Block use with RC.P & RC.M enclosures - IP65 Description MRP Flush Push Button Spring Return Projecting Push Button Mushroom Spring Return Mushroom Stay Put (No's) RP2-BA RP2-BA2 RP2-BA3 RP2-BA RP2-BA5 RP2-BA6 RP2-BA334 RP2-BA335 RP2-BL RP2-BL2 RP2-BL3 50 RP2-BL4 RP2-BL5 RP2-BL6 RP2-BC2 RP2-BC3 RP2-BC4 78 RP2-BC5 RP2-BC6 RP2-BS RP2-BS RP2-BS Product Picture Operating Heads for Control Stations Without Contact Block and Carrier Description Selector 2-Position, Stay Put Selector 3-Position, Stay Put (Centre OFF) Selector 3-Position, Spring Return (Centre OFF) Key Selector 2-Position, Stay Put Key Selector 2-Position, Stay Put Key Selector 2-Position, Stay Put Key Selector 2-Position, Spring Return Stay Put Key Selector 3-Position, Stay Put Key Selector3- Position, Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Both Side Spring Return Mushroom Head with Key Stay Put RP2-BD2 RP2-BD3 RP2-BDR3 RP2-BG2 RP2-BG4 RP2-BG02 RP2-BG6 RP2-BG3 RP2-BG0 RP2-BG5 RP2-BG9 RP2-BG09 RP2-BG7 RP2-BS4 Operating Handle Standard Standard Standard Key removable in L.H. position Key removable in both positions Key removable in R. H. position Key removable in L.H. position Key removable in centre position Key removable in all positions Key removable in L.. H. & R. H. position Key removable in L. H. position Key removable in R. H. position Key removable in Centreposition MRP Std. Pkg. (No's) 0 Key removable in both positions 27 8 Product Picture

77 Push Button Operating Head for Control Stations For Customer assembly Metallic Operating Heads without contact Block for RC.P & RC.M enclosures - IP65 Contact Blocks - Base Mounted For Control Stations Customer Assembly Description MRP (No's) Product Picture Description Contact Type MRP (No's) Product Picture Flush Push Button Spring Return Projecting Push Button Mushroom Spring Return Mushroom Stay Put Mushroom Push-Pull Type RM2-BA RM2-BA2 RM2-BA3 RM2-BA4 RM2-BA5 RM2-BA6 RM2-BA334 RM2-BA RM2-BL RM2-BL2 RM2-BL3 RM2-BL RM2-BL5 RM2-BL6 RM2-BC2 RM2-BC3 RM2-BC RM2-BC5 RM2-BC6 RM2-BS RM2-BS RM2-BS RM2-BT Contact Block RB2BE-0B M/P * NO Slow Break RB2BE-02B M/P * NC * Please specify 'M' if required for Metallic and 'P' if required for Plastic. Legends (Stickers) are supplied with the following standard texts, Plastic Description Start Forward Up On Open Auto Reset Slow RP2-BY2303 RP2-BY2305 RP2-BY2307 RP2-BY23 RP2-BY233 RP2-BY235 RP2-BY2323 RP2-BY2327 Standard Text Stop Reverse Down Off Close Hand Inch Fast RP2-BY2304 RP2-BY2306 RP2-BY2308 RP2-BY232 RP2-BY234 RP2-BY236 RP2-BY232 RP2-BY2328 MRP (No's.) 7 00 Operating Heads for Control Stations Without Contact Block and Carrier Description Selector 2-Position, Stay Put Selector 2- Position, Spring Return Selector 3-Position, Stay Put (Centre OFF) Selector 3-Position, Spring Return (Centre OFF) Key Selector 2-Position, Stay Put Key Selector 2-Position, Stay Put Key Selector 2-Position, Stay Put RM2-BD2 RM2-BDR2 RM2-BD3 RM2-BDR3 RM2-BG2 RM2-BG4 RM2-BG02 Key Selector 2-Position, RM2-BG6 Spring Return Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put Key Selector 3-Position, Stay Put RM2-BG3 RM2-BG0 RM2-BG5 Operating Handle Standard Standard Standard Standard Key removable in L.H. position Key removable in both positions Key removable in R. H. position Key removable in L.H. position Key removable in centre position Key removable inall positions Key removable in L.H. & R.H. position MRP Std. Pkg. (No's) Product Picture Power On Right O RP2-BY2326 RP2-BY2309 RP2-BY246 RP2-BY92 RP2-BY94 Note: Minimum order of #0 each. Emer. Stop RP2-BY2330 Left -- RP2-BY230 RP2-BY247 RP2-BY93 RP2-BY95 Legends (Stickers) are supplied with the following standard texts, Metal Description Start Forward Up On Open Auto Reset Slow RM2-BY2303 RM2-BY2305 RM2-BY2307 RM2-BY23 RM2-BY233 RM2-BY235 RM2-BY2323 RM2-BY2327 Standard Text Stop Reverse Down Off Close Hand Inch Fast RM2-BY2304 RM2-BY2306 RM2-BY2308 RM2-BY232 RM2-BY234 RM2-BY236 RM2-BY232 RM2-BY2328 Power On RM2-BY2326 Emer. Stop RM2-BY2330 MRP (No's.) 7 00 Key Selector 3-Position, Stay Put RM2-BG9 Key removable in L. H. position Right RM2-BY2309 Left RM2-BY230 Key Selector 3-Position, Stay Put Key Selector 3-Position, Both Side Spring Return RM2-BG09 RM2-BG7 Key removable in R. H. position Key removable in Centre position 250 O RM2-BY246 RM2-BY92 RM2-BY94 -- RM2-BY247 RM2-BY93 RM2-BY95 Mushroom Head with Key Stay Put RM2-BS4 Key removable in both positions Note: Minimum order of #0 each.

78 Anmol Motor Starter Anmol Motor Starters for Agri Segment Single Phase DOL Starter in S.S. Enclosure with 2P Contactor & 2P OLR type LR7D Relay Range (Amp) Std. Power Rating for Single Phase Motor at 220V AC KW HP MRP BE-ASA2025MU20 4.0~ BE-ASA2025MU22 5.5~ BE-ASA2025MU24 7.0~ BE-ASA2025MU26X 9.0~ BE-ASA2525MU22 3.0~ BE-ASA2525MU ~ Submersible Pump Starter Single Phase Submersible Pump Starter-Economical Standard Model in S.S. Enclosure incorporating Single Phase Submersible Pump Starter-Economical Model in S S Enclosure Incorporating 2 Pole Definite Purpose Contactor, Single Pole MCB, Ammeter, ON/OFF Push Button, Motor ON Indicator with provision of terminal for dry run relay Std. Power Rating for Single Phase Motor at 220V AC Capacitor Rating (MFD) MCB Rating 'C' Curve KW HP Run 0kA MRP (No's) BE-SSEDP202U5C BE-SSEDP202U5C BE-SSEDP202U5C BE-SSEDP202U5C BE-SSEDP202U5C Single Phase Submersible Pump Starter - Economical Deluxe Model in S.S. Enclosure incorporating Single Phase Submersible Pump Starter-Economical Model in S S Enclosure Incorporating 2 Pole Definite Purpose Contactor, 2 Pole Oveload relay type LR7D, Ammeter, Voltmeter ON/OFF Push Button, Motor ON Indicator with provision of terminal for dry run relay Relay Range (Amps) Std. Power Rating for Single Phase Motor at 220V AC Capacitor Rating (MFD) KW HP Run Start MRP (No's) BE-SDEDP202U ~ /00 BE-SDEDP202U ~ / BE-SDEDP202U ~ / BE-SDEDP202U526X 9.0~ / BE-SDEDP202U522X 4~ / Single Phase Submersible Pump Starter suitable for wide band operating range 60V~260V 50Hz AC

79 Anmol Motor Starter Single Phase Submersible Pump Starter-Deluxe Model in S.S. Enclosure-Heavy duty 2 Pole Contactor, 2P Overload Relay Type LR7D, Supressed scale Voltmeter & Ammeter with provisition of terminals for dryrun relay Relay Range (Amp) Std. Power Rating for Single Phase Motor at 220V AC Capacitor Rating (MFD) KW HP Run Start BE-SDA2025MU20 4.0~ /00 BE-SDA2025MU22 5.5~ / BE-SDA2025MU24 7.0~ /20 BE-SDA2025MU24H 7.0~ / BE-SDA2025MU26X 9.0~ /20 BE-SDA2025MU26XM 9.0~ /20 BE-SDA2025MU26XH 9.0~ / BE-SDA2025MU26XA 9.0~ / BE-SDA2025MU22H 3.0~8.0 20/50 BE-SDA2525MU ~ /50 BE-SDA2525MU22X 4.0~ / BE-SDA2525MU222M 8.0~ /200 BE-SDA2525MU222H 8.0~ / BE-SDA4025MU ~ / MRP (No's) 6 DOL in S.S. Enclosure incorporating - Heavy Duty 4 Pole Contactor type TC-DX with wide band operating coil, Overload relay type LR3D with manual re-set and yellow flag for trip indication Relay Range (Amp) MRP BE-DXM ~2.5 BE-DXM ~4.0 BE-DXM ~6.0 BE-DXM BE-DXM BE-DXM204 36X BE-DXM BE-DXM254 32X 4-22 BE-DXM BE-DXM Auto Start DOL Starter in SS Enclosure incorporating - Heavy Duty 4 Pole Contactor type TC-DX with wide band operating coil, Overload relay type LR3D with manual re-set and yellow flag for trip indication. Electronic Auto Switch for protection against Single Phase, phase reversal & phase unbalance and 3 position selector switch-spp Auto/SPP Manual/Manual having provision of 6 way terminal block for bottom cable entry Relay Range (Amp) MRP BE-DXSD ~2.5 BE-DXSD ~4.0 BE-DXSD ~6.0 BE-DXSD BE-DXSD BE-DXSD204 36X BE-DXSD BE-DXSD254 32X 4-22 BE-DXSD BE-DXSD Automatic Star Delta Starter in S.S Enclosure incorporating - Heavy Duty 4 Pole Contactor type TC-DX with wide band operating coil, Overload relay type LR3D for motor protection & Electronic Star Delta Timer Relay Range (Amp) Std. Power Rating for 3 P at 45V BE3-DXM ~ BE3-DXM ~ BE3-DXM ~ BE3-DXM ~0 9 2 BE3-DXM204 36X 9.0~4 5 KW HP MRP 6800 BE3-DXM ~ BE3-DXM254 32X 4.0~22 BE3-DXM ~ BE3-DXM ~

80 Anmol Motor Starter Semi Automatic Star Delta Starter in S.S Enclosure incorporating - Heavy Duty 4 Pole Contactor type TC-DX with wide band operating coil, Overload relay type LR3D for motor protection Relay Range (Amp) BE3-DXM204 34SA 7.0~0 9 2 BE3-DXM204 36XSA 9.0~4 5 Std. Power Rating for 3 Phase Motor at 45V MRP KW HP 6200 BE3-DXM204 32SA 3.0~ BE3-DXM254 32XSA 4.0~ BE3-DXM SA 8.0~25 2 BE3-DXM SA 23.0~ Submersible Pump Starter with 3 Position Selector Switch Submersible Pump Starter DOL - Deluxe Model incorporating - Heavy Duty 4 Pole Contactor type TC-DX, Overload relay type LR3D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection Relay Range (Amp) MRP BE-SPSDDX ~4.0 BE-SPSDDX ~6.0 BE-SPSDDX ~ BE-SPSDDX ~0 BE-SPSDDX204 36X 9.0~4 BE-SPSDDX ~ BE-SPSDDX254 32X 4~22 BE-SPSDDX ~25 BE-SPSDDX ~32 BE-SPSDDX ~ Submersible Pump Starter DOL - Standard Model incorporating - Heavy Duty 4 Pole Contactor type TC-DX, Overload relay type LR3D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual, Voltmeter, Suppressed scale Ammeter, Motor ON & Trip LED indicator Relay Range (Amp) MRP BE-SPSSDX ~4.0 BE-SPSSDX ~6.0 BE-SPSSDX ~ BE-SPSSDX ~0 BE-SPSSDX204 36X 9.0~4 BE-SPSSDX ~ BE-SPSSDX254 32X 4~22 BE-SPSSDX ~ BE-SPSSDX ~32 BE-SPSSDX ~ Submersible Pump Starter Automatic Star Delta - Deluxe Model incorporating - Heavy Duty 4 Pole Contactor type TC-DX, Overload relay type LR3D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, RYB LED Indicator Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection Relay Range (Amp) MRP BE3-SPSDDX ~4.0 BE3-SPSDDX ~6.0 BE3-SPSDDX ~ BE3-SPSDDX ~0 BE3-SPSDDX204 36X 9.0~4 BE3-SPSDDX ~ BE3-SPSDDX254 32X 4~22 BE3-SPSDDX ~ BE3-SPSDDX ~ BE3-SPSDDX ~ BE3-SPSDDX ~ BE3-SPSDD6335NW359* 48~ BE3-SPSDD8035NW36* 57~ *Wide band Coil NW has operating range 250~440V AC 6

81 Anmol Motor Starter Submersible Pump Starter Automatic Star Delta - Standard Model incorporating - Heavy Duty 4 Pole Contactor type TC-DX, Overload relay type LR3D, Auto Start Switch, 3 Position selector switch for SPP Auto/ SPP Manual / Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED indicator Relay Range (Amp) MRP BE3-SPSSDX ~4.0 BE3-SPSSDX ~6.0 BE3-SPSSDX ~ BE3-SPSSDX ~0 BE3-SPSSDX204 36X 9.0~4 BE3-SPSSDX ~ BE3-SPSSDX254 32X 4~22 BE3-SPSSDX ~ BE3-SPSSDX ~ BE3-SPSSDX ~ BE3-SPSSDX ~ BE3-SPSSD6335NW359* 48~ BE3-SPSSD8035NW36* 57~ *Wide band Coil NW has operating range 250~440V AC Thermal Overload Relays 3 Pole type LR3D-Direct Mounting Relay Range (Amp) MRP LR3D ~2.50 LR3D ~4.0 LR3D LR3D LR3D LR3D236X LR3D LR3D632X LR3D Thermal Overload Relays 2 Pole type LR7D - Direct Mounting Relay Range (Amp) MRP LR7-D ~2.50 LR7-D ~4.0 LR7-D LR7-D LR7-D LR7-D226X LR7-D LR7-D622X 4-22 LR7-D LR7-D ** Anmol Starters portfolio available in the above standard coil voltage only. # Wide operating band encapsulated coils with its operating range. How to order Starter n Complete the code by replacing the black square ( ) by the letter(s) corresponding to the Coil Voltage selected. n Starters / Submersible Pump Starter selection should be based on the FLC of Pump/Motor & Coil Voltage required as per installation. n Anmol Starters should be ordered in standard packing for each model. Coil Voltage Codes (Standard) for Submersible Pump Starter/DOL/Auto DOL Starter Voltage Coil Voltage (AC) 50Hz 90~ ~450 Coil Code** Q N

82 Anmol Motor Starter Anmol Motor Starter Spares Description MRP 2P Contactor NO Volt Coil 220/240V AX-D2 MU 220 Std. Pkg. (No's.) 4P Contactor NO Volt Coil 380V TX-D20 Q or N 230 Pneumatic SD Timer (-30 Sec) TA2-DS2 460 Electronic SD Timer (-30 Sec) TCET030SD45VAC 60 Start NO Block LA9-D Front mounted Aux. Contact block 2 NO for 2P Contactor Front mounted Aux. Contact block NO+NC for 4P Contactor ON Indicating Lamp (Green) TRIP Indicating Lamp (Red) LA-D20A 60 TA-DNA 60 RCB7IVL74-45V RCB7IVL73-45V R Phase LED indicating Lamp Y Phase LED indicating Lamp B Phase LED indicating Lamp RCB7IVL74-240V RCB7IVL78-240V RCB7IVL76-240V 20 0 Terminal Block, 2 way, 5A TB2W5A 70 Terminal Block, 3 way, 60A TB3W60A 20 0 Terminal Block, 6 way, 60A TB6W60A 230 Contactor Extension Block for SDS Relay Extension Block for SDS EXT0 EXT Stop Push button (Red) PBTL 0 0 Connector Assy. for Autoswitch (BE-DXS) CASPP 00 0 Voltage Selector Switch SPVSS0 70 Ammeter ( A) Ammeter ( A) Ammeter (0-75/5A) Ammeter (0-00/5A) AM20A AM50A AM755 AM Voltmeter (0-500V) VM Ammeter ( A) Ammeter ( A) Ammeter ( A) Voltmeter (0-300V) AM0A AM5A AM25A VM Terminal Block, 3 way, 30A TB3W30A 20 Single Phase Preventor TCAS

83 Industrial Motor Starter Motor Starters for Industrial Segment Conforming IS Industrial Motor starter - Type DX-P Heavy Duty DOL Starter Type DX-P with robust 4 Pole Contactor & LRD OLR in S.S. enclosure Std. Power Rating for 3 Ph. Motor at 45V HP KW Relay LRD Range Amps.5. BE-DXP ~ BE-DXP ~ BE-DXP ~ BE-DXP ~ BE-DXP ~ BE-DXP204 36X 9~4 MRP 950 (No's) BE-DXP ~ BE-DXP254 32XH 4~22 BE-DXP ~ BE-DXP ~ Heavy Duty Automatic Star Delta Starter Type DX-P with robust 4 Pole Contactor & LRD OLR, Electronic Star Delta Timer in S.S. enclosure Std. Power Rating for 3 Ph. Motor at 45V HP KW Relay LRD Range Amps BE3-DXP ~8.0 MRP (No's) 2 9 BE3-DXP ~ BE3-DXP204 36X 9~4 BE3-DXP ~ BE3-DXP254 32XH 4~ BE3-DXP ~ BE3-DXP ~ AC Coil Voltage Codes (Standard) for Heavy Duty Industrial Starter Type DX-P Industrial Starter Voltage BE-DXP ~400# 250~450# BE3-DXP - 90~400# 250~450# Coil Code M Q N # Industrial Starters are available in the above wide band operating range Standard coil voltages. Industrial Motor Starter with D range Contactor & LRD Overload Relay DOL Starter with D range Contactor & LRD OLR in Plastic Enclosure Std. Power Rating for 3 Ph. Motor at 45V Relay Range Amps MRP HP KW LE-D ~.00 (No's) LE-D ~ LE-D ~ LE-D ~ LE-D ~ LE-D ~ LE-D73 36X 9.0 ~ LE-D ~ LE-D ~

84 Industrial Motor Starter Motor Starters for Industrial Segment Conforming IS DOL Starter with D range Contactor & LRD OLR in S.S. Enclosure Std. Power Rating for 3 Ph. Motor at 45V Relay Range Amps MRP HP KW BE-D ~ BE-D ~ BE-D ~ BE-D ~ BE-D ~ BE-D ~ BE-D735 36X 9.0~ BE-D ~8.0 5 BE-D ~ BE-D ~ BE-D ~ BE-D ~ BE-D ~ (No's) Reversing Starter with D range Contactor & LRD OLR in S.S Enclosure Std. Power Rating for 3 Ph. Motor at 45V Relay Range Amps MRP HP KW BE2-D ~ BE2-D ~ BE2-D ~ BE2-D ~ BE2-D ~ BE2-D ~ BE2-D ~ BE2-D735 36X 9.0~ BE2-D ~ BE2-D ~ BE2-D ~ (No's) Non Stockable item Automatic Star Delta Starter with D range Contactor, LRD OLR & Electronic Star Delta Timer Std. Power Rating for 3 Ph. Motor at 45V Relay Range Amps MRP KW HP 3 4 BE3-D ~ BE3-D ~ BE3-D ~ BE3-D ~ BE3-D735 36X 9.0 ~ BE3-D ~ BE3-D ~ BE3-D ~ BE3-D ~ BE3-D ~ BE3-D ~ BE3-D ~ BE3-D8035N ~ BE3-F ~ BE3-F5N ~ BE3-F50N ~ BE3-F85N ~ BE3-F85N ~ BE3-F265N ~ BE3-F330N ~ BE3-F330S ~ (No's)

85 Industrial Motor Starter Motor Starters for Industrial Segment Conforming IS Semi-Automatic Star Delta Starter with D range Contactor, LRD OLR Std. Power Rating for 3 Ph. Motor at 45V Relay Range Amps MRP KW HP 3 4 BE3-D SA 2.5 ~ BE3-D735 30SA 4.0 ~ BE3-D735 32SA 5.5 ~ BE3-D735 34SA 7.0 ~ BE3-D735 36XSA 9.0 ~ BE3-D SA 3.0 ~ BE3-D SA 8.0 ~ (No's) Coil Voltage Codes (Standard) for DOL Starters with D range Contactor Motor Starter Voltage BE-D / LE-D 220V 45V Coil Code UW N ** DOL Motor Starter are available only in the above Standard Coil Voltages. Coil Voltage Codes (Standard) for DOL & Star Delta Starters with D range Contactor Motor Starter Voltage BE-D / BE2-D / BE3-D / BE3-F 380# 45 Coil Code NW N # Wide Band Coil available for Star Delta Starters upto 40 HP only. How to order Industrial Starter: (i) Complete the code by replacing the blue square ( ) by the letter(s) corresponding to the Coil Voltage selected. (ii) Industrial DOL Starters should be selected based on the FLC of Pump/Motor & Coil Voltage required. How to order Star Delta Starter: (I) Complete the code by replacing the blue square ( ) by the letter(s) corresponding to the Coil Voltage selected. (ii) Star Delta starters should be selected based on the FLC of the Pump/Motor phase current (Motor FLC X 0.58) & Coil Voltage required. Custom Built Motor Starters Solutions n Smart Start Delta Starter rating 40 HP to 50 HP 3 Phase 45V AC - Incomer 3 Pole MCCB, 0~25kA - Selection of liberal D range, air break Contactor Electronic motor protection relay with built-in MCU having D-time 0.30 sec for motor protection against single phasing - Electronic Star Delta Timer - Housed in free standing IP 54 sheet steel enclosure with bottom cable entry - Optional facility: Water Level Controller also available n Intellignet Star Delta Starter rating 40 HP to 350 HP 3 Phase 45V AC - Incomer 3 Pole MCCB, 0~25kA - Selection of liberal D range, air break Contactor - Digital motor protection Relay type mpro00 with 7 segment display to assure complete motor protection against overload, phase loss, under current, unbalance, motor stall, earth fault, lock rotar - Electronic Star Delta Timer - Housed in free standing IP 54 sheet steel enclosure with bottom cable entry n Intelligent Auto Transformer Starter rating 40 HP to 350 HP 3 Phase 45V AC - Incomer 3 Pole MCCB, 0~25kA - Selection of liberal D range, air break Contactor - Digital motor protection Relay type mpro00 with 7 segment display to assure complete motor protection against overload, phase loss, under current, unbalance, motor stall, earth fault, lock rotar - Auto Transformar, air cooled, 6 starts/hours with built-in thermister having tapping at 50%, 60% & 80% of the rated voltage - Electronic Timer for changeover function - Housed in free standing IP 54 sheet steel enclosure with bottom cable entry Non Stockable item

86

87 MRP w.e.f. 23 rd April 202

88 MCB WiNtrip2 Miniature Circuit Breaker Two stage easy snapping device for Din Rail Mounting Bi-connect terminals for Cable and Busbar B-Series Lighting & Distribution with no Surge Current Current rating (Amps.) Product Code MRP Pole 6 CSMBSB6 70 Current rating (Amps.) 3 Pole Product Code MRP 6 CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B CSMBSB CSMBS3B Pole + N 3 Pole + N 6 CSMBSB6N CSMBS3B6N 26 0 CSMBSB0N CSMBS3B0N 26 6 CSMBSB6N CSMBS3B6N CSMBSB20N CSMBS3B20N CSMBSB25N CSMBS3B25N CSMBSB32N CSMBS3B32N CSMBSB40N CSMBS3B40N CSMBSB50N CSMBS3B50N CSMBSB63N CSMBS3B63N Pole 4 Pole 6 CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B CSMBS2B CSMBS4B63 782

89 MCB WiNtrip2 Miniature Circuit Breaker C-Series Inductive load with surge current - Motor Circuit Applications Current rating (Amps.) Product Code MRP Current rating (Amps.) Product Code MRP Pole 0.5 CSMBSC Pole 0.5 CSMBS3C CSMBSC 277 CSMBS3C 98 2 CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C CSMBSC CSMBS3C Pole + N 3 Pole + N 0.5 CSMBSC0.5N CSMBS3C0.5N 32 CSMBSCN 630 CSMBS3CN 32 2 CSMBSC2N CSMBS3C2N 32 3 CSMBSC3N CSMBS3C3N 32 4 CSMBSC4N CSMBS3C4N 32 5 CSMBSC5N CSMBS3C5N 32 6 CSMBSC6N CSMBS3C6N 43 0 CSMBSC0N CSMBS3C0N CSMBSC6N CSMBS3C6N CSMBSC20N CSMBS3C20N CSMBSC25N CSMBS3C25N CSMBSC32N CSMBS3C32N CSMBSC40N CSMBS3C40N CSMBSC50N CSMBS3C50N CSMBSC63N CSMBS3C63N Pole 0.5 CSMBS2C Pole 0.5 CSMBS4C CSMBS2C 725 CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C CSMBS2C CSMBS4C63 850

90 MCB WiNtrip2 Miniature Circuit Breaker D-Series High Inductive Load & High Inrush Current Current rating (Amps.) Product Code MRP Current rating (Amps.) Product Code MRP Pole 0.5 QCSMBSD Pole 0.5 QCSMBS3D QCSMBSD 298 QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D QCSMBSD QCSMBS3D Pole + N 3 Pole + N 0.5 QCSMBSD0.5N QCSMBS3D0.5N 734 QCSMBSDN 880 QCSMBS3DN QCSMBSD2N QCSMBS3D2N QCSMBSD3N QCSMBS3D3N QCSMBSD4N QCSMBS3D4N QCSMBSD5N QCSMBS3D5N QCSMBSD6N QCSMBSD0N QCSMBS3D6N QCSMBS3D0N QCSMBSD6N QCSMBS3D6N QCSMBSD20N QCSMBS3D20N QCSMBSD25N QCSMBS3D25N QCSMBSD32N QCSMBS3D32N QCSMBSD40N QCSMBS3D40N QCSMBSD50N QCSMBS3D50N QCSMBSD63N QCSMBS3D63N Pole 0.5 QCSMBS2D Pole 0.5 QCSMBS4D QCSMBS2D 820 QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS2D QCSMBS4D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QCSMBS2D QCSMBS4D QNon Stockable item

91 MCB WiNtrip2 Miniature Circuit Breaker 2 DC-Series Current rating (Amps.) MRP Current rating (Amps.) MRP Pole 2 Pole 0.5 QCSMBSDC QCSMBS2DC QCSMBSDC 340 QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC QCSMBSDC QCSMBS2DC WiNtrip2 Isolator Current rating (Amps.) Pole MRP 25 CSMBSISO CSMBSISO Current rating (Amps.) 3 Pole MRP 25 CSMBS3ISO CSMBS3ISO IS/IEC CSMBSISO CSMBSISO CSMBS3ISO CSMBS3ISO CSMBSISO CSMBS3ISO CSMBSISO CSMBS3ISO Pole 4 Pole 25 CSMBS2ISO CSMBS4ISO CSMBS2ISO CSMBS4ISO CSMBS2ISO CSMBS2ISO CSMBS4ISO CSMBS4ISO CSMBS2ISO CSMBS4ISO CSMBS2ISO CSMBS4ISO25 65 QNon Stockable item

92 MCB WiNtrip Miniature Circuit Breaker Two stage easy snapping device for Din Rail Mounting Bi-connect terminals for Cable and Busbar B-Series Lighting & Distribution with no Surge Current Current rating (Amps.) Product Code MRP Current rating (Amps.) Product Code MRP Pole 3 Pole 6 CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B CSMBB CSMB3B Pole + N 3 Pole + N 6 CSMBB6N CSMB3B6N CSMBB0N CSMB3B0N CSMBB6N CSMB3B6N CSMBB20N CSMB3B20N CSMBB25N CSMB3B25N CSMBB32N CSMB3B32N CSMBB40N CSMB3B40N CSMBB50N CSMB3B50N CSMBB63N CSMB3B63N Pole 4 Pole 6 CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B CSMB2B CSMB4B63 920

93 MCB WiNtrip Miniature Circuit Breaker C-Series Inductive load with surge current - Motor Circuit Applications Current rating (Amps.) Product Code MRP Current rating (Amps.) Product Code MRP Pole 3 Pole 0.5 CSMBC CSMB3C CSMBC 290 CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C CSMBC CSMB3C Pole + N 3 Pole + N 0.5 CSMBC0.5N CSMB3C0.5N 400 CSMBCN 670 CSMB3CN CSMBC2N CSMB3C2N CSMBC3N CSMB3C3N CSMBC4N CSMB3C4N CSMBC5N CSMB3C5N CSMBC6N CSMB3C6N 20 0 CSMBC0N CSMB3C0N CSMBC6N CSMB3C6N CSMBC20N CSMB3C20N CSMBC25N CSMB3C25N CSMBC32N CSMB3C32N CSMBC40N CSMB3C40N CSMBC50N CSMB3C50N CSMBC63N CSMB3C63N Pole 0.5 CSMB2C Pole 0.5 CSMB4C CSMB2C 770 CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C CSMB2C CSMB4C Higher Rating Miniature Circuit Breakers Pole 80 CSMBC80 00 CSMBC00 POR 3 25 CSMBC25 2 Pole 80 CSMB2C80 00 CSMB2C00 POR 3 25 CSMB2C25 3 Pole 80 CSMB3C80 00 CSMB3C00 25 CSMB3C25 4 Pole 80 CSMB4C80 00 CSMB4C00 25 CSMB4C25 IEC: POR POR

94 MCB WiNtrip Miniature Circuit Breaker D-Series High Inductive Load & High Inrush Current Current rating (Amps.) Product Code MRP Current rating (Amps.) Product Code MRP Pole 3 Pole 0.5 QCSMBD QCSMB3D QCSMBD 30 QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D QCSMBD QCSMB3D63 60 Pole + N 3 Pole + N 0.5 QCSMBD0.5N QCSMB3D0.5N 755 QCSMBDN 925 QCSMB3DN QCSMBD2N QCSMB3D2N QCSMBD3N QCSMB3D3N QCSMBD4N QCSMB3D4N QCSMBD5N QCSMB3D5N QCSMBD6N 80 6 QCSMB3D6N QCSMBD0N QCSMB3D0N QCSMBD6N 80 6 QCSMB3D6N QCSMBD20N QCSMB3D20N QCSMBD25N QCSMB3D25N QCSMBD32N QCSMB3D32N QCSMBD40N QCSMB3D40N QCSMBD50N QCSMB3D50N QCSMBD63N QCSMB3D63N Pole 0.5 QCSMB2D Pole 0.5 QCSMB4D QCSMB2D 870 QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QCSMB2D QCSMB4D QNon Stockable item

95 MCB WiNtrip Miniature Circuit Breaker 2 DC-Series Current rating (Amps.) MRP Current rating (Amps.) MRP Pole 2 Pole 0.5 QCSMBDC QCSMB2DC QCSMBDC 360 QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC QCSMBDC QCSMB2DC WiNtrip MCB Type Changeover Switch IS/IEC Description Pole / Rating MRP Two way centre OFF Changeover Switch 2P/ 25A CSCOS2P25A 00 Two way centre OFF Changeover Switch 2P/ 40A CSCOS2P40A 650 Two way centre OFF Changeover Switch 4P/ 25A CSCOS4P25A 200 Two way centre OFF Changeover Switch 4P/ 40A CSCOS4P40A WiNtrip Isolator IS/IEC Current rating (Amps.) MRP Current rating (Amps.) MRP Pole 3 Pole 25 CSMBISO CSMB3ISO CSMBISO CSMB3ISO CSMBISO CSMBISO CSMB3ISO CSMB3ISO CSMBISO CSMB3ISO CSMBISO CSMB3ISO Pole 4 Pole 25 CSMB2ISO CSMB4ISO CSMB2ISO CSMB4ISO CSMB2ISO CSMB2ISO CSMB4ISO CSMB4ISO CSMB2ISO CSMB4ISO CSMB2ISO CSMB4ISO Accessories (Site fitted with MCB) Current rating (Amps.) Auxillary Contact MRP Current rating (Amps.) Shunt Trip MRP QNO+NC CSMBAXSF 500 Q2VDC - - Q2VDC Q24VDC CSMBS02SF CSMBS024SF 550 Q24VDC - - Q48VDC CSMBS048SF Q48VDC - - Q220VAC - - Q0VAC Q220VAC CSMBS0SF CSMBS220SF 500 QNon Stockable item

96 RCCB WiNtrip Residual Current Circuit Breaker Current rating (Amps.) 2 Pole 4 Pole Sensitivity MRP 6 CSRB2P6A CSRB2P6A CSRB2P6A CSRB2P20A CSRB2P20A CSRB2P20A CSRB2P25A CSRB2P25A CSRB2P25A CSRB2P32A CSRB2P32A CSRB2P32A CSRB2P40A CSRB2P40A CSRB2P40A CSRB2P63A CSRB2P63A CSRB2P63A CSRB2P80A CSRB2P80A CSRB2P80A CSRB2P00A CSRB2P00A CSRB2P00A CSRB4P6A CSRB4P6A CSRB4P6A CSRB4P20A CSRB4P20A CSRB4P20A CSRB4P25A CSRB4P25A CSRB4P25A CSRB4P32A CSRB4P32A CSRB4P32A CSRB4P40A CSRB4P40A CSRB4P40A CSRB4P63A CSRB4P63A CSRB4P63A CSRB4P80A CSRB4P80A CSRB4P80A CSRB4P00A CSRB4P00A CSRB4P00A Note: Rating from 6A to 63A conforms to IS and as ISI marked

97 Distribution Board WiNtrip Distribution Board Acrylic Cover Consumer Unit Description No. of Modules (Incomer+Outgoing) MRP SPN WC 04 WAY SD WITH ACRYLIC WINDOW CSDBSPNSDA SPN WC 06 WAY SD WITH ACRYLIC WINDOW CSDBSPNSDA SPN WC 08 WAY SD WITH ACRYLIC WINDOW CSDBSPNSDA SPN WC 0 WAY SD WITH ACRYLIC WINDOW CSDBSPNSDA SPN WC 2 WAY SD WITH ACRYLIC WINDOW CSDBSPNSDA SPN WC 6 WAY SD WITH ACRYLIC WINDOW CSDBSPNSDA SPN Distribution Board Description No. of Modules (Incomer+Outgoing) MRP 04 Way Single Door CSDBSPNSD Way Single Door CSDBSPNSD Way Single Door CSDBSPNSD Way Single Door CSDBSPNSD Way Double Door CSDBSPNDD Way Double Door CSDBSPNDD Way Double Door CSDBSPNDD Way Double Door CSDBSPNDD TPN Distribution Board - Horizontal Description No. of Modules (Incomer+Outgoing) MRP 04 Way Single Door CSDBTPNHSD Way Single Door CSDBTPNHSD Way Single Door CSDBTPNHSD Way Single Door CSDBTPNHSD Way Single Door CSDBTPNHSD Way Double Door CSDBTPNHDD Way Double Door CSDBTPNHDD Way Double Door CSDBTPNHDD Way Double Door CSDBTPNHDD Way Double Door CSDBTPNHDD SPN WiNclass Distribution Board Description No. of Modules (Incomer+Outgoing) MRP 2+04 Way Single Door CSDBSPNSD04S Way Single Door CSDBSPNSD08S Way Single Door CSDBSPNSD2S Way Single Door CSDBSPNSD6S Way Double Door CSDBSPNDD04S Way Double Door CSDBSPNDD08S Way Double Door CSDBSPNDD2S Way Double Door CSDBSPNDD6S TPN WiNclass Distribution Board Description No. of Modules (Incomer+Outgoing) MRP 04 Way Single Door DB CSDBTPNHSD04S Way Single Door DB CSDBTPNHSD06S Way Single Door DB CSDBTPNHSD08S Way Single Door DB CSDBTPNHSD2S Way Single Door DB CSDBTPNHSD6S Way Double Door DB CSDBTPNHDD04SN Way Double Door DB CSDBTPNHDD04S Way Double Door DB CSDBTPNHDD06S Way Double Door DB CSDBTPNHDD08S Way Double Door DB CSDBTPNHDD2S Way Double Door DB CSDBTPNHDD6S

98 Distribution Board WiNtrip Distribution Board PPI Distribution Board Description MRP 4 Way Double Door CSDBTPNPPIDD Way Double Door CSDBTPNPPIDD Way Double Door CSDBTPNPPIDD Way Double Door CSDBTPNPPIDD Phase Selector Distribution Board TPN Phase Selector DD DB for incorporating MCB / Isolator / RCCB, equipped with 3 Nos 63A Phase selector switches & 3 No Piano Switches Description MRP 4 Way DD with 63A R/S CSDBPHSDD04RS Way DD with 63A R/S CSDBPHSDD06RS Way DD with 63A R/S CSDBPHSDD08RS Way DD with 63A R/S CSDBPHSDD2RS Way DD with 40A R/S CSDBPHSDD04RS Way DD with 40A R/S CSDBPHSDD06RS Way DD with 40A R/S CSDBPHSDD08RS Way DD with 40A R/S CSDBPHSDD2RS Way DD without R/S CSDBPHSDD Way DD without R/S CSDBPHSDD Way DD without R/S CSDBPHSDD Way DD without R/S CSDBPHSDD2 930 VTPN Distribution Board (with provision for MCB as incomer) Description No. of Modules (Incomer+Outgoing) MRP 4 way Double Door CSDBTPNVDD way Double Door CSDBTPNVDD way Double Door CSDBTPNVDD way Double Door CSDBTPNVDD VTPN Distribution Board (with provision for MCCB as incomer) Description MRP MCCB as incomer 00A DD04 Way IP43 CSDBMCCB00DD04IP MCCB as incomer 00A DD08 Way IP43 CSDBMCCB00DD08IP MCCB as incomer 00A DD2 Way IP43 CSDBMCCB00DD2IP MCCB as incomer 225A DD04 Way IP43 CSDBMCCB225DD04IP MCCB as incomer 225A DD08 Way IP43 CSDBMCCB225DD08IP MCCB as incomer 225A DD2 Way IP43 CSDBMCCB225DD2IP MCCB Selection Guide Description 3 Pole & 4 Pole - CS2A3*/ CSCN3*/ CSCN4*/CSCS3*/ CSCS4* & CSC2N3*/CSC2N4 Type/ Breaking Capacity Ics=00%Icu MCCB Rating CSDBMCCB00DD04IP43 CS2A3=0kA 75,00A CSDBMCCB00DD08IP43 CSCN=4kA 5, 20, 30, 40 & 50A CSDBMCCB00DD2IP43 CSCS=8kA 5, 20, 30, 40 & 50A CSC2N=8kA 60, 75 & 00A CSDBMCCB225DD04IP43 00, 25, 50, 75 3POLE & 4POLE-CSC4N3*/ CSC4N4* CSC4N=26kA 200 & 250A /CSC4S3*/CSC4S4* CSDBMCCB225DD08IP43 CSDBMCCB225DD2IP43 CSC4S=37kA 50, 75, 200 & 250A Note: Replace *with MCCB code eg. MCCB 3Pole, 4kA, 50A~CSCN350

99 Distribution Board WiNtrip Distribution Board 7 Segment Distribution Board Description MRP CSDB7SEGDD Segment TPN DD DB With Provision for FP MCB/Isolator/RCCB as CSDB7SEGDD incomer, DP MCB/Isolator/RCCB as sub incomer and SP MCBs as outgoing CSDB7SEGDD CSDB7SEGDD Price on request : Prewired Distribution Board fitted with Busbar, Terminal Block for incoming/outgoing phase neutral & Earth duly wired with Provision for ISO/RCCB/MCB as incomer and SP outgoing (without MCBs) FLEXI (Tier) DBs (with Metal Door) Description MRP FLEXI DD DB 2 ROW 3MODULES CSDBFLDD2R3 34 FLEXI DD DB 3 ROW 3MODULES CSDBFLDD3R FLEXI DD DB 4 ROW 3MODULES CSDBFLDD4R Double Door DB (with Acrlic Window) Description MRP SPN Distribution Board Double Door 4 Way CSDBSPNDDA SPN Distribution Board Double Door 8 Way CSDBSPNDDA SPN Distribution Board Double Door 2 Way CSDBSPNDDA SPN Distribution Board Double Door 6 Way CSDBSPNDDA WiNtrip Cable End Box TPNH Cable End Box Double Door Distribution Board Description MRP TPNH 4 way CSDBCBTPNHDD TPNH 6 way CSDBCBTPNHDD TPNH 8 way CSDBCBTPNHDD TPNH 2 way CSDBCBTPNHDD2 545 TPNH 6 way CSDBCBTPNHDD6 605 TPNV Cable End Box Double Door Distribution Board Description MRP TPNV 4 way CSDBCBTPNVDD TPNV 8 way CSDBCBTPNVDD TPNV 2 way CSDBCBTPNVDD2 275 WiNtrip Telephone & Television Socket Distribution Board Box Double Door Distribution Board Description MRP SPN 04 way Tel & TV Socket DB (2+4) CSDBSPNDDTELTV SPN 06 way Tel & TV Socket DB (2+6) CSDBSPNDDTELTV SPN 08 way Tel & TV Socket DB (2+8) CSDBSPNDDTELTV SPN 0 way Tel & TV Socket DB (2+0) CSDBSPNDDTELTV SPN 2 way Tel & TV Socket DB (2+2) CSDBSPNDDTELTV SPN 4 way Tel & TV Socket DB (2+4) CSDBSPNDDTELTV TPN 04 way Tel & TV Socket DB (8+2) CSDBTPNDDTELTV TPN 06 way Tel & TV Socket DB (8+8) CSDBTPNDDTELTV TPN 08 way Tel & TV Socket DB (8+24) CSDBTPNDDTELTV TPN 2 way Tel & TV Socket DB (8+36) CSDBTPNDDTELTV2 6375

100 Plug and Socket DBs WiNtrip Plug and Socket DBs (without MCB) Powder Coated Sheet Metal Deep Drawn DBs with Plug & Socket including insulated Neutral link, adjustable Din Rail and connecting links. Description MRP (No.s) 0Amp SPN CSDBPSSPN Amp SPN CSDBPSSPN Amp SPN (SP Cutout) CSDBPSSPN020SP Amp TPN CSDBPSTPN Amp TPN CSDBPSTPN WiNtrip Plug and Sockets (Metal Clad) Description MRP (No.s) 0Amp SPN Plug CSDBPSPN Amp SPN Socket CSDBSSPN Amp SPN Plug CSDBPSPN Amp SPN Socket CSDBSSPN Amp TPN Plug CSDBPTPN Amp TPN Socket CSDBSTPN Amp TPN Plug CSDBPTPN Amp TPN Socket CSDBSTPN WiNtrip Metal Enclosures (with Din Rail) For Mounting WiNtrip MCBs / RCCBs / Isolators Description MRP (No.s) SP Enclosure CSDBMCBESP DP Enclosure CSDBMCBEDP TP Enclosure CSDBMCBETP FP Enclosure CSDBMCBEFP WiNtrip Plastic Enclosure without MCB Description MRP Plastic MCB Enclosure SP&DP/STD CSDBMCBEPDP 00 Plastic MCB Enclosure TP&FP/STD CSDBMCBEPFP 40 MCB Enclosure IP55 4 Pole Description MRP (No.s) MCB Enclosure IP55 04 Way CSDBEP04 00 MRP w.e.f. 6 th June 204

101

102

103

Maximum Retail Price

Maximum Retail Price Price List Power Distribution Components Product Name Page No. WiNmaster Air Circuit Breaker 9-0 WiNmaster ACB Order Form Air Circuit Breaker - "AH" Series 2-9 ACB Order Form - "AH" Series 20 Power Capacitor

More information

6 List Price w.e.f. 23 rd April 2012

6 List Price w.e.f. 23 rd April 2012 6 List Price w.e.f. 23 rd April 2012 List Price w.e.f. 10 23 th rd April 2009 2012 7 8 List Price w.e.f. 23 rd April 2012 ACB WiNmaster WiNmaster Air Circuit Breaker Features : LSING Protection True RMS

More information

C-POWER Spares & Accessories W.E.F Units per Cat

C-POWER Spares & Accessories W.E.F Units per Cat C-POWER Spares & Accessories W.E.F. 01-07-2017 Description Units per Cat ACB Product Management No. Pole Assy. Fix ACBs Pole Assy. 400-1250 S1 FIX SL95601OOOO 25,620 1 18% 8538 Pole Assy. 800/1000 C FIX

More information

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB 1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications

More information

Deepika Enterprises.

Deepika Enterprises. +91-8048572696 Deepika Enterprises https://www.deepikaenterprises.co.in/ We are prominent suppliers, traders, wholesalers and distributors of an extensive range of Electrical and Automation Products. Owing

More information

Siemens switchgear. Tried, tested, trusted. Circuit Breakers

Siemens switchgear. Tried, tested, trusted. Circuit Breakers * MP - Maximum etail Price Siemens Ltd. LV SG - Power Distribution Products MP Eff. 01-10-2014 13 MCCB: Sentron 3VT1...5 ated current - 16A to 1600A 3 and 4 pole versions Breaking capacity from 25kA to

More information

TECHNICAL SPECIFICATIONS OF PCC PANEL

TECHNICAL SPECIFICATIONS OF PCC PANEL S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational

More information

Product development is a continuous process. For Latest product related information kindly contact nearest branch office

Product development is a continuous process. For Latest product related information kindly contact nearest branch office C-Power Spares and accessories Cat Nos Description Image SL93881OOOO Pole Assy. 800/1000 C FIX SL93882OOOO Pole Assy. 1250/1600 C FIX SL93883OOOO Pole Assy. 2000 C FIX SL93884OOOO Pole Assy. 2500 C FIX

More information

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES price list THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2014 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 13 cat.a Ui690V Uimp6kV 50 60Hz

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2015 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC)

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MAY 2018 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES AUGUST 2017 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 12 cat.a Ui690V Uimp6kV 50 60Hz

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0 Controlgear Products +27 () 11 97 116 sales@controlgear.co.za Siemens stock items on hand as at Mon, 3/4/218, 14:4 GMT+2 3NA3824-6 LV HRC FUSE LINK S 8A 69AC 25DC 3 3NA3832 LV HRC FUSE LINK GL/GG S 125A

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Contents. We build a better future! MCC HCB

Contents. We build a better future! MCC HCB H8PU Low Voltage We build a better future! HYUNDAI s low voltage motor control center H8PU series with a withdrawable unit are of multi-tier, factory assembled and for rated voltage of up to 660V AC. Contents

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

Partnership that you can trust. LV Switchgear Motor Control Products.

Partnership that you can trust. LV Switchgear Motor Control Products. s Partnership that you can trust LV Switchgear Motor Control Products Maximum etail Price w.e.f. st October, 204 www.siemens.co.in s SIMOCODE pro S Get your motor control center s intelligent and compact

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

* With I-Option card only (C. T. connection) Basic connections with isolated contacts Typical Circuit Diagrams. Typical Circuit Diagrams Basic connections with isolated contacts F2 - Overload relay Q1 - MPCB / ACB / MCCB /K2 - Main isolating contactors (AC-3 rated) F3 - Semiconductor Fuses

More information

Control and protection of the electrical energy

Control and protection of the electrical energy Specialists in CONTROL & EFFICIENCY of electrical motors Automation and Industrial Control Control and protection of the electrical energy Efficiency in the most ambitious projects thanks to the confidence

More information

Technical Section: Miniature Circuit Breakers

Technical Section: Miniature Circuit Breakers MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs MARCH Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI 240 25 (HIC) 480 7.5 600 5 DRX100B P. 07 DMX³ ACB from 630 A to 6300 A Fixed version

More information

LG Moulded Case Circuit Breakers - 3P

LG Moulded Case Circuit Breakers - 3P Model Description ka at 415V GBN103/16 100AF/16AT 3P MCCB GBN103/20 100AF/20AT 3P MCCB GBN103/25 100AF/25AT 3P MCCB GBN103/32 100AF/32AT 3P MCCB GBN103/40 100AF/40AT 3P MCCB GBN103/50 100AF/50AT 3P MCCB

More information

U-POWER & OMEGA (Common) Spares & Accessories

U-POWER & OMEGA (Common) Spares & Accessories U-POWER & OMEGA (Common) Spares & Accessories Sr No. Description Cat Nos. MRP Cat No GST Rate HSN Code 1 Rating Error Preventor CL90926OOOO 710 1 18% 8538 2 Racking Handle CL90010OOOO 1,660 1 18% 8538

More information

Low Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd.

Low Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd. With effect from st March 205 Low Voltage Products Price list ABB low voltage products ABB is a global leader in power and automation technologies that enable utility and industry customers to improve

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Motor Circuit Breakers C3

Motor Circuit Breakers C3 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID S.NO. HEAD DESCRIPTION AMOUNT (Rs.) 1 A DG SETS & ACCESSORIES

More information

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR AN ISO 9001 & 14001 COMPANY TENDER DOCUMENT TENDER No: DLI/CON/696/411 FOR SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 11/0.433KV INDOOR/OUTDOOR ELECTRIC SUBSTATION AND OTHER ASSOCIATED EXTERNAL ELECTRICAL

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

Authorised Distributor

Authorised Distributor Authorised Distributor Email: Vishal@Sanghavi.co.in Vishal@Roopal.in www.sanghavi.co.in With effect from 6 th March 206 Electrification Products Price List (`) Electrification products ABB is a global

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

Vacuum Switchgear Type VMX Spares Manual

Vacuum Switchgear Type VMX Spares Manual Vacuum Switchgear Type VMX Spares Manual Vacuum Switchgear Type VMX Spares Manual Foreward This manual has been primarily designed for easy identification of components / sub-assembly. Ordering Components

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Electrification Products Price List (`) ABB Authorised Distributor Spot India Group Tel:

Electrification Products Price List (`) ABB Authorised Distributor Spot India Group Tel: With effect from 9 th December, 206 Electrification Products Price List (`) Electrification products ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits 7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:

More information

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers .1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

An electrical panel capable of evolving

An electrical panel capable of evolving An electrical panel capable of evolving Prisma TT Low voltage factory built assemblies Buildings Commercial & Industrial Make the most of your energy General For a dependable electrical installation Total

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

C1251N DC and C1251N 1000 V

C1251N DC and C1251N 1000 V T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P2 46034 P4 46036 C25N 000 V basic frame (separate components - fixed/fc)

More information

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge. Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR TENDER DOCUMENT (TENDER No: ) FOR BALANCE WORK OF SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF TWO NO. 11/0.433KV INDOOR ELECTRIC SUBSTATION (ESS-1 & 2), THREE NO. OUTDOOR TYPE 11/0.433KV COMPACT SUB-STATION

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Manufacturer Item Number Item Description QTY Available ABB 1SAM250000R1007 MS , THERMAL AND ELECTROMAGNETIC TRIP 5 ABB

Manufacturer Item Number Item Description QTY Available ABB 1SAM250000R1007 MS , THERMAL AND ELECTROMAGNETIC TRIP 5 ABB ABB 1SAM250000R1007 MS116-2.5, THERMAL AND ELECTROMAGNETIC TRIP 5 ABB 1SAZ211201R1043 TA25-DU-11A-THERMAL-OVERLOAD 0 ABB 1SAZ211201R1047 TA25-DU-19A-THERMAL-OVERLOAD 3 ABB 1SAZ211201R1051 TA25-DU-25A-THERMAL-OVERLOAD

More information

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures .2....6 special versions High performance range H for 000V/AC Circuit breaker for 7V/DC DC circuit breaker up to 0V/DC Miniature circuit breakers A.7.8.0 Technical data Economy range N, V/AC Standard range

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Intelligent Choice for Prestigious Buildings

Intelligent Choice for Prestigious Buildings Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug