* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Size: px
Start display at page:

Download "* With I-Option card only (C. T. connection) Basic connections with isolated contacts"

Transcription

1 Typical Circuit Diagrams. Typical Circuit Diagrams Basic connections with isolated contacts F2 - Overload relay Q1 - MPCB / ACB / MCCB /K2 - Main isolating contactors (AC-3 rated) F3 - Semiconductor Fuses (Optional) BH - Command "Ramp-up" BF - Command "Enable" ME - Monitoring signal "In operation" MH - Monitoring signal "End of ramp" Only with I-Option card MU - Monitoring signal "Overload". * With I-Option card only (C. T. connection) 230 V AC external power supply *** Thermistor or thermostat motor protection.1

2 Typical Circuit Diagrams Control through PLC Basic connections for PLC with 24 V = industry logic Q1- MPCB / ACB / MCCB - Main isolating contactor (AC-3 rated) F3 - Semiconductor Fuses (Optional) F2 - Overload relay L - is preferably to be earthed. Remove link 49-0 if there is a potential difference between L - and PE (max. permissible voltage 60 V) * With I-Option card only (C. T. connection) *** Thermistor or thermostat motor protection.2

3 Typical Circuit Diagrams Recommended connection : 3RW24 Line Connection for Soft Start (also with I-OPTION card) = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button (Momentary command) S2 = ON push button (Momentary command) * With I-Option only (C. T. connection).3

4 Typical Circuit Diagrams Recommended connection : 3RW24, Delta Connection for Soft Start (also with I-Option card) = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button S2 = ON push button *MU - only with I-Option card * With I-Option only (C. T. connection).4

5 Typical Circuit Diagrams Recommended connection : 3RW24, Line Connection Soft Start and Soft Stop (also with I-Option card) = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button S2 = ON push button K2 = Auxiliary contactor (4 NO) * With I-Option only (C. T. connection).

6 Typical Circuit Diagrams Recommended connection : 3RW24, Line connection as a Soft Start and Soft Stop for reversing application F3 = Semiconductor fuses (Optional) f = Main isolating contactor in forward direction R = Main isolating contactor in reverse direction ON1 = Forward direction ON2 = Reverse direction K3 = Bypass contactor (Optional) K2f = Auxiliary contactor (4NO + 4NC) K2R = Auxiliary contactor (4NO + 4NC) S1 = OFF push button (Momentary Contact) S2.0 = ON push button S2.1 (Momentary Contact) * With I-Option only (C. T. connection) 230 VAC, external power supply.6

7 Typical Circuit Diagrams Recommended connection : 3RW24, Line connection (also with I-Option) for soft start and speed change of motors in the pole-change Dahlander connection. This connection provides for zero-current contactor switching F3 = Semiconductor fuses (Optional) = Main isolating contactor (AC-3 rated) K3 = Bypass contactor (Optional) K4 = Auxiliary contactor (3NO + 1NC) K = Auxiliary contactor (4NO) K21 = Contactor - Slow speed 1 = Aux. Contactor (4NO) 2 = Aux. Contacor (4NO) K22-1= Star contactor (Dahlander wdg. only) S2 = ON slow speed S3 = ON high speed S1 = Off command F4 = Overload relay * With I-Option card only (C.T. Connection).7

8 Typical Circuit Diagrams Recommended connection : 3RW24, Line connection I-Option card combined with a star/delta starter for starting with low starting currents (e.g. screw compressors in bypass). PE L1 L2 L3 2 ~ V F1 K MU * F2 S1 OFF F2 S2 ON K6 F3 ** G1 k PE L1 L2 L3 F k4 k4 K2 k3 k4 ME MH BH 6 7 P10 3RW24 O PE 49 0 K2 k3 8BF 9 SW 10 K6 K3 K2 k4 T1 T2 * T3 H K2 K3 W1 V1 U1 M 3 ~ W2 V2 U2 F3 = Semiconductor fuses = Bypass contactor K2 = Delta contactor K3 = Star contactor K4 = ON -delay timers S1 = OFF Push button S2 = ON Push button K6 = Line contactor * With I-Option card only (C.T. Connection).8

9 Typical Circuit Diagrams Recommended connection : 3RW24, Delta connection combined with a star/ delta starter for emergency starting) F1 = Semiconductor fuses F3 = Motor feeder HRC fuses = Bypass contactor K2 = Delta contactor K3 = Star contactor K = Auxiliary contactor (3NO + 1NC) K4 = 7PU60 star-delta timer S1 = OFF push button S2 = ON push button S3 = Star-delta change over switch K6 = Line contactor * With I-Option card only (C. T. connection) Rapid push button start is not possible. Push button must be pressed for sufficient time..9

10 Typical Circuit Diagrams Recommended connection : 3RW24, Line connection as a voltage controller (e.g. for running the motor at lower speed, special motor, control of electric heating) F1 = Motor feeder fuses = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses US -11 = 10kΩ potentiometer * With I-Option card only *** Thermistor or thermostat motor protection.10

2. SIKOSTART 3RW24 Principle of Operation 2.1 Starting & Stopping Continuous Operation Protection and Control... 2.

2. SIKOSTART 3RW24 Principle of Operation 2.1 Starting & Stopping Continuous Operation Protection and Control... 2. CONTENTS Page No. 1. Introduction 1.1 Motor Transmission System... 1.1 1.2 Conventional Starting Methods... 1.4 1.3 Why use 3RW24 Controllers... 1.6 1.4 Features of 3RW24... 1.7 2. 3RW24 Principle of Operation

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3) Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3) 1 Model Wise Descriptions: Sr. No Model Product Description 21.3.1 POW-1 Single Phase SCR Power Controller for single phase

More information

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible

More information

3RW Soft Starters. General data. 6/4 Siemens LV

3RW Soft Starters. General data. 6/4 Siemens LV General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of peaks Avoidance of mains voltage fluctuations during starting

More information

An Engineering Guide to. Soft Starters

An Engineering Guide to. Soft Starters An Engineering Guide to Soft Starters Contents 1 Introduction 5 1.1 General 5 1.2 Benefits of soft starters 5 1.3 Typical Applications 6 1.4 Different motor starting methods 7 1.5 What is the minimum

More information

For Operation in the Control Cabinet 3RW Soft Starters

For Operation in the Control Cabinet 3RW Soft Starters General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008 Siemens AG 2008 General data The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft

More information

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0

More information

Dimensions WxHxD [mm] Weight [kg]

Dimensions WxHxD [mm] Weight [kg] SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly

More information

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS MCD 3000 Soft starter THE PERFECT SOFTENER OF ROUGH STARTS The MCD Soft starter ranging from 7.5 to 800 kw is the optimum solution to a range of

More information

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase Siemens AG 2008 3RW Soft Starters Selection and ordering data 28-1BB14 38-1BB14 47-1BB14 Ambient temperature 40 C Ambient temperature 50 C Size DT Order No. Price Rated Rated power of Rated Rated power

More information

Price List July 2017

Price List July 2017 Price List July 2017 CONTENTS S. No Item Page No. 1 MCCB and Adjustable MCCB 3 2 MCB, MEM DOL STARTERS, AUX BLOCK, WATER PUMP PRESSURE SWITCHES 3 Motor Protection Breakers, Enclosure, Auxiliary Blocks

More information

4491 en / c. D IGISTART et. Reference guide

4491 en / c. D IGISTART et. Reference guide 449 en - 0.06 / c 4 5 6 D IGISTART et Reference guide Contents Page Introduction 5. General 5. Benefits of soft starters 5. Typical Applications 6.4 Different motor starting methods 7.5 What is the minimum

More information

Pocket Guide VLT Soft Starter the single speed drive

Pocket Guide VLT Soft Starter the single speed drive MAKING MODERN LIVING POSSIBLE Pocket Guide VLT Soft Starter the single speed drive Contents Soft Starter Selection Guide Warnings... 5 Common Applications... 6 MCD Soft Starter Features and Specifications...

More information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / / Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.

More information

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10 Contents Contents 1 Safety 5 Safety 5 Warnings 5 2 Introduction 7 Feature List 7 Type Code 8 3 Installation 9 Mechanical Installation 9 Dimensions and Weights 10 4 Electrical Installation 11 Control Wiring

More information

Low cost, internally bypassed non optimizing soft starter

Low cost, internally bypassed non optimizing soft starter Robust General Purpose Low Voltage Soft Starters Low cost, internally bypassed non optimizing soft starter 15.5 500 A Robust General Purpose Simplified Installation Internally Bypassed Competitive with

More information

Open Chassis Star-Delta Starter User Guide

Open Chassis Star-Delta Starter User Guide Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...

More information

FAN-STOP INSTRUCTION MANUAL

FAN-STOP INSTRUCTION MANUAL Form 1289 FAN-STOP INSTRUCTION MANUAL IMPORTANT Read these instructions fully BEFORE INSTALLING. Equipment damage and personal injury may result from improper installation and/or use. 1. Instructions 1.

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Soft starters SIRIUS 3RW30 / 3RW40. Manual 01/2010. Industrial Controls. Answers for industry.

Soft starters SIRIUS 3RW30 / 3RW40. Manual 01/2010. Industrial Controls. Answers for industry. Soft starters Manual 01/2010 Industrial Controls Answers for industry. Introduction 1 Safety information 2 Industrial Controls Soft starters Manual Product description 3 Product combinations 4 Functions

More information

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections. F A I R F O R D E L E C T R O N I C S Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to Basic Guide to the Installation and Operation Of the Soft Starter 5MC software

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443 CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters

More information

ABB s new control and protection devices

ABB s new control and protection devices ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for

More information

Fairford Electronics Product Selector

Fairford Electronics Product Selector Fairford Electronics Product Selector Step 1 - Select Product. XFE PFE QFE DFE HFE Example Step 1 - An XFE has been chosen because of its features and value for money. Step 2 - The application is selected

More information

SOLSTART Instruction Manual

SOLSTART Instruction Manual Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Programmable Logic Controller. Mat Nor Mohamad

Programmable Logic Controller. Mat Nor Mohamad Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors

More information

Pocket Guide VLT Soft Starter the single speed drive

Pocket Guide VLT Soft Starter the single speed drive MAKING MODERN LIVING POSSIBLE Pocket Guide VLT Soft Starter the single speed drive Contents Soft Starter Selection Guide Warnings... 5 Common Applications... 6 MCD Soft Starter Features and Specifications...

More information

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0) This is Crompton Controls Installation and Maintenance Instructions S0 & Smooth-BRAKE DC Injection Brake Modules LT0 Issue Tel: + (0)9 8 DC Injection Brake Module Installation and Maintenance Document

More information

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Operating Instructions VLT Soft Starter - MCD 500 Contents Contents 1 Safety 5 1.1 Safety 5 2 Introduction 7 2.1.1 Feature List 7 2.1.2 Type Code 8 3 Installation 9 3.1 Mechanical

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44 RW40/44 Catalog Supplement July 2005 sirius RW40 RW44 Reduced Voltage Electronic Soft Starts Catalog Technical information SIRIUS soft starters /2 Introduction / General data For standard applications

More information

Technical specifications

Technical specifications Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith

More information

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500 MAKING MODERN LIVING POSSIBLE Operating Instructions VLT Soft Starter - MCD500 Contents Contents 1 Safety 5 1.1 Safety 5 2 Introduction 6 2.1.1 Feature List 6 2.1.2 Type Code 7 3 Installation 8 3.1 Mechanical

More information

For Operation in the Control Cabinet

For Operation in the Control Cabinet As an option the thyristors can also be protected by SITOR semiconductor fuses from short-circuiting so that the soft starter is still functional after a short-circuit (type of coordination ). Three LEDs

More information

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION 1-3 MANUAL STARTERS EXERCISE OBJECTIVE Examine and describe the operation of manual motor starters. DISCUSSION Motor starters are made out of power switches and overload protection devices. They can be

More information

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter DFE Fairford low cost, internally bypassed non-optimizing Soft Starter DFE Internally Bypassed Soft Starter 22-500 Amps The DFE is Fairford s internally bypassed, nonoptimizing Soft Starter which is perfect

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006 General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

Contactor Relays 3TH30

Contactor Relays 3TH30 Contactor Relays 3TH30 Reliability and safety are pre-requisites in the choice of the control contactor. Siemens 3TH30 contactor relays satisfy these criteria and thus offer the right choice to the customer.

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Fincor Series 2230 MKII/2240

Fincor Series 2230 MKII/2240 Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new

More information

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000 .5 00 (mm)hxwxd (Amps) 0x,5x, CSA, A: :0 (AC5b) 5A: 8:0000 0xx8 5A: 65:0080 0xx8 0 T C V Remote operation Series + protection Remote operation of 0, 0 and 00 is facilitated by the dedicated remote operator

More information

Guide to contents - applicable to

Guide to contents - applicable to FAIRFORD ELECTRONICS Basic Guide to the Installation and Operation Of the QFE Soft Starter Guide to contents - applicable to 5MC software V55 Mechanical Outlines Referring to the appropriate size of QFE,

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to

Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to 5MC software V56 Basic Guide to the Installation and Operation Of the Soft Starter 1 Mechanical Outlines Referring to

More information

Panorama. Softstarters The complete range

Panorama. Softstarters The complete range Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated

More information

RVS-DN Digital Soft Starter A, V Instruction Manual

RVS-DN Digital Soft Starter A, V Instruction Manual RVS-DN Digital Soft Starter 8-2700A, 220-1000V Instruction Manual Ver. 171001 Table of Contents Page Subject Appendix Page Subject 2 Starter Selection 41 Table of content 3 Installation 42 UL and cul instructions,

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1... 100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes

More information

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs Why soft start a motor? The most significant benefits of soft starting a motor come from reduced mechanical and electrical stress. This not only translates to lower maintenance costs, but significantly

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries Product Brochure AC motor speed control products and peripherals for the motion and automation control industries The motor speed control experts www.motorcontrolwarehouse.co.uk Rev 1 The Motor Control

More information

Motor Starters, Soft Starters and Load Feeders

Motor Starters, Soft Starters and Load Feeders Motor Starters, Soft Starters and Load Feeders Contents Pages Introduction............................................................6/2 For Operation in the Control Cabinet General data........................................................6/3

More information

Metering Products Protection Units Current Transformers. April 1, 2015

Metering Products Protection Units Current Transformers. April 1, 2015 Metering Products Protection Units Current Transformers April, 0 With Effect From April, 0 Sr.No Description Model No. Multifunction LED Meters POWER ANALYZER - LED VIPS 80P 00 POWER ANALYZER - LED 0-

More information

Electronic timers CT-S range Function diagrams

Electronic timers CT-S range Function diagrams CT-S range Function diagrams - X1-Z2 = ON- delay CT-ERS, CT-MBS, CT-MFS t = set delay time / ts = storing time; t = t1 + t2 = OFF-delay CT-AHS, CT-MBS, CT-MFS X1-Z2 t = set delay time / ts = storing time;

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

Exercise 1-3. Manual Starters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Direct-on-line (DOL) starters. Reversing starters

Exercise 1-3. Manual Starters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Direct-on-line (DOL) starters. Reversing starters Exercise 1-3 Manual Starters EXERCISE OBJECTIVE Examine and describe the operation of manual motor starters. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Direct-on-line

More information

RVS-DN Instruction Manual

RVS-DN Instruction Manual RVS-DN Digital Soft Starter 8-3000A, 220-1000V Instruction Manual Ver. 27/02/2009 2 Table of content RVS-DN Instruction Manual 1. TABLE OF CONTENT 1. Table of content...2 2. Safety & Warnings...5 2.1 Safety...5

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET Candidate Code No. ET49 For Board Use Only Result Date Int Result Date Int ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three hours

More information

Pressure Makeup Jockey Pump Controller

Pressure Makeup Jockey Pump Controller Hubbell Industrial Controls, Inc. A subsidiary of Hubbell Incorporated 4301 Cheyenne Dr. Archdale, NC 27263 Telephone (336) 434-2800 FAX (336) 434-2803 Instruction Manual Pressure Makeup Jockey Pump Controller

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0 Controlgear Products +27 () 11 97 116 sales@controlgear.co.za Siemens stock items on hand as at Mon, 3/4/218, 14:4 GMT+2 3NA3824-6 LV HRC FUSE LINK S 8A 69AC 25DC 3 3NA3832 LV HRC FUSE LINK GL/GG S 125A

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Low-Voltage Controls and Distribution

Low-Voltage Controls and Distribution Motor Starters, Soft Starters and Load Feeders 3RW30 / 3RW40 Soft Starters Reference Manual April 2009 Low-Voltage Controls and Distribution Motor Starters, Soft Starters and Load Feeders 4 Introduction

More information

HIB Enclosed Inverter User Guide

HIB Enclosed Inverter User Guide HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit

More information

Operating Instructions VLT Soft Starter MCD 500

Operating Instructions VLT Soft Starter MCD 500 MAKING MODERN LIVING POSSIBLE Operating Instructions VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Operating Instructions Contents 1 Safety 6 1.1 Warnings 6 2 Introduction 8 3 Installation

More information

SCR POWER REGULATORS & HEATING CONTROL PANELS. 1/2/3-Phase 15 ~ 750+ Amps 220 ~ 480 V AC.

SCR POWER REGULATORS & HEATING CONTROL PANELS. 1/2/3-Phase 15 ~ 750+ Amps 220 ~ 480 V AC. SCR POWER REGLATORS & 1/2/3-Phase 15 ~ 750+ Amps 220 ~ 480 V AC SCR POWER REGLATORS & Radix SCR Power Regulators Radix offers a full range of SCR Power Regulators as well as SCR Heating Control Panels.

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral

More information

Deepika Enterprises.

Deepika Enterprises. +91-8048572696 Deepika Enterprises https://www.deepikaenterprises.co.in/ We are prominent suppliers, traders, wholesalers and distributors of an extensive range of Electrical and Automation Products. Owing

More information

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008 General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents Section 1.0 Warnings... 2 Section 2.0 Description 2.1 Overview... 3 2.2 Inside delta ratings... 3 2.3 Isolation... 3 2.4 Supply voltage... 3 Contents Section 3.0 Section 4.0 Kit Installation 3.1 Overview...

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive.  For any soft start situation MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple start-stop operation to high end performance.

More information

For Operation in the Control Cabinet

For Operation in the Control Cabinet For Operation in the Cabinet 3RW30 for standard applications Overview The SIRIUS 3RW30 soft starters reduce the motor voltage through variable phase control and increase it in ramp-like mode from a selectable

More information

MCD Pump Application Module

MCD Pump Application Module Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

Aldi V4 & V V1.1 5/23/2014

Aldi V4 & V V1.1 5/23/2014 Aldi V4 & V5 2012 2013 V1.1 5/23/2014 Aldi Control Techniques SK Series VFD & Hussmann MX Series MicroChannel Condenser Equipment Operation Component Orientation Control Wiring Programming and Start Up

More information

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 SECTION 1. 600V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 Soft Starters SECTION 2. LIQUID COOLED VFD I 3 Liquid Cooled

More information

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 Soft starts Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal

More information

SIRIUS Soft Starters Introduction

SIRIUS Soft Starters Introduction Introduction Overview Products at a glance 3RW30/3RW31 3RW40 3RW44 Class 73/74 Enclosed 16 CONTROL SIRIUS soft starters for standard applications SIRIUS 3RW30 soft starters SIRIUS 3RW40 soft starters for

More information

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device Modular Application (AC Motors) Engineering and Technical Teaching Equipment AEL-AI12 INTRODUCTION An electrical motor is such an electromechanical device which converts electrical energy into a mechanical

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

J TS 7090 Thyristor power switch

J TS 7090 Thyristor power switch M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Thyristor Power Regulators

Thyristor Power Regulators READY TO USE SCR-BASED HIGH PERFORMANCE & ENERGY EFFICIENT 1-PHASE, 2-PHASE AND 3-PHASE POWER REGULATORS SCR POWER REGULATORS FROM 15 AMPS TO 750 AMPS AND HIGHER Description RADIX brings you a full range

More information

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Application example of a motor controlled by MCD100 and protected by a circuit breaker VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.

More information

Motor Starters, Soft Starters and Load Feeders

Motor Starters, Soft Starters and Load Feeders Motor Starters, Soft Starters and Load Feeders Contents Pages Introduction................................... 7/2 For Operation in the Control Cabinet General data.................................. 7/3

More information