Full Voltage Starters NEMA Style
|
|
- Elisabeth Watson
- 6 years ago
- Views:
Transcription
1 Full Starters Style SO, -Pole Starter lass 86 / Refer to atalog 80T70 eneral Information S magnetic starters are used for full-voltage starting and stopping of squirrel cage motors. overload protection is provided via melting alloy type thermal overload relays. S starters are available in s 00 through 7, and are designed for operation at Vac, 0 to z. Solid State Overload Relay Protection ( Logic ) These ambient insensitive overload relays are available on s 00 through 6 and standard on size 7. They provide phase loss, phase unbalance protection. To order, add Form 0 (for selectable trip class or 0 protection). For more information about Logic, see pages 6-8 and 6-. dapted Bimetal ( s 00 ) The dapted Bimetal motor starter consists of a specially designed adapter that attaches with bus bars to the S contactor and holds the LRD or LRD (IE Style) bimetal overload relay. This starter configuration can be ordered by adding Form E (adapater only) to the standard catalog number. Once the FL of the motor has been determined, the LRD or LRD bimetal overload can be purchased separately and installed in the field at a later date. For more information see Table 6.6. TeSys T Management System ( s 6) TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T can predict what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. For additional information about TeSys T Management System, see pages 6-84 to 6-88 and page 6-. -Pole Polyphase Vac Maximum0 z Note that prices shown do not include thermal units. Devices require thermal units (s 00 6). Standard trip thermal units are $.0 each. See page 6-6 Table 6.: 00 -/ -/ Open 4 & 4X Brushed Stainless Steel ( 0-)a 4X, orrosion-resistant lass-polyester SOb Sb 4.00 Use 0 Use SBOb SBb 8.00 SBWb 7.00 SBWb 7.00 Schneider Electric offers express shipping for factory modified and /R Enclosed Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. sk for Laser Delivery, then select the product and the modifications you need when you place your order. It s as easy as that! / 7-/ SOb 7.00 Sb.00 SWb.00 SWb.00 SDOb.00 SDb.00 SDWb SDWb SEOb SEb.00 SEWb SEWb SFOb 7.00 SFb.00 SFWb SFWb 8.00 SOb.00 Sb 4.00 SWb SOb Sb SWb.00 6 /DEFINITE PURPOSE TYPE SJOb 6.00 SJb SJWb.00 a 6 and 7 are rated 4 only, painted sheet steel. b oil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. 6-8 Discount 0 Schneider Electric P
2 Full Starters Style lass 86 / Refer to atalog 80T70 Table 6.4: -Pole Polyphase Vac Maximum0 z Note that prices shown do not include thermal units. Devices require thermal units (s 00 6). Standard trip thermal units are $.0 each. See page 6-6 Ironb Bolted luminumd 7 & For azardous Locations Div. & lass I roups, D lass II roups E, F, & SPIN TOP /Ra Dusttight & Driptight Industrial Use 00 -/ -/ Use 0 Use 0 Use SBTc SBT4c 0.00 SBRc 6.00 SBc / 7-/ STc ST4c 4.00 SRc Sc SDTc SDT4c 6.00 SDRc.00 SDc SET4c 4.00 SERc SEc SFT4c SFRc 7.00 SFc ST4c SRc 6.00 Sc Sc SJc.00 a enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 6- for more information. b Limited to Pilot Light and Selector Switch or Start-Stop Push-Button. c oil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection Table 6.4 shown on page 6-8. d 7 and bolted cast aluminum are not UL listed. Table 6.4: oil odes z 0 z 4e 0f ode V0 V0 V08 V0 V04 V06 V07 V dder. Schneider Electric offers express shipping for factory modified and /R Enclosed Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. sk for Laser Delivery, then select the product and the modifications you need when you place your order. It s as easy as that! e 4 V coils are not available on s 4 7. On s 00-, where 4 V coils are available, Form S (separate control) must be specified (i.e., order as 86SBOV0S). f 0 Volt Polyphase contactors are wired for separate control. Form S (separate control) must be specified (i.e., order as 86SOV0S). Note: For voltage codes used with control transformers, see page 6-. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions page 6-4 Factory Modifications (Forms) page 6-0 Separate s (lass ) page 6- Replacement Parts (lass 8) page 6- S ccessories (lass ) page 6-8 For ow to Order Information, see page 6-. /DEFINITE PURPOSE TYPE 6 0 Schneider Electric P Discount 6-
3 Full Starters -Pole Vac Maximum0 z lass 86 / Refer to atalog 80T70 Table 6.4: Note that prices shown do not include thermal units. Devices require thermal unit. Standard trip thermal units are $.0 each. See page / Open 4 & 4X Brushed Stainless Steel 4X, orrosion-resistant lass-polyester SOa Sa 4.00 Use 0 Use SBOa 4.00 SBa SBWa SBWa SOa Sa.00 SWa.00 SWa.00 P 6 SOa Sa SWa 0.00 SWa / SDO6a 8.00 SD6a SDW6a 0.00 SDW6a Pole, - Vac Maximum0 z Table 6.44: Note that prices shown do not include thermal units. Devices require thermal units. Standard trip thermal units are $.0 each. See page 6-6 Open 4 & 4X Brushed Stainless Steel 4X, orrosion-resistant lass-polyester 0 8 SBOa 6.00 SBa SBWa.00 SBWa / 7-/ SO4a S4a SW4a.00 SW4a.00 4 SDOa 8.00 SDa.00 SDWa.00 SDWa SEOa SEa 7.00 SEWa 6.00 SFOa 4.00 SFa 7.00 SFWa.00 onsult Schneider Electric at ( ) a oil voltage code must be specified to order this product. Refer to standard coil voltage codes listed below. Table 6.4: oil odes z 0 z ode dder 6 /DEFINITE PURPOSE TYPE 4b 0c V0 V0 V08 V0 V04 V06 V07 V b 4 V coils are not available on s 4 7. On sizes 00, where 4 V coils are available, Form S (separate control) must be specified (i.e., order as 86SBOV0S). c 0 Volt Polyphase starters are wired for separate control. Form S (separate control) must be specified (i.e., order as 86SOV0S). Note: For voltage codes used with control transformers, see 6-. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions page 6-4 Factory Modifications (Forms) page 6-0 Separate s (lass ) page 6- Replacement Parts (lass 8) page 6- S ccessories (lass ) page 6-8 For ow to Order Information, see page Discount 0 Schneider Electric P
4 Full Starters -Pole Vac Maximum0 z lass 86 / Refer to atalog 80T70 Table 6.46: Note that prices shown do not include thermal units. Devices require thermal unit. Standard trip thermal units are $.0 each. See page / Ironc Bolted luminuma 7 & azardous Locations, Div. & lass I, roups & D lass II, roups E, F, & SPIN TOP /Rb Dusttight & Driptight Industrial Use Use 0 Use 0 Use SBTd SBT SBRd 6.00 SBd STd ST SRd 7.00 Sd 7.00 P 6 STd ST SRd.00 Sd / SDT6d SDT46.00 SDR6d SD6d a 7 and bolted cast aluminum are not UL listed. 4-Pole - Vac Maximum0 z Table 6.: Note that prices shown do not include thermal units. Devices require thermal units. Standard trip thermal units are $.0 each. See page 6-6 oil Ironc Bolted luminum 7 & azardous Locations lass I, roups & D lass II, roups E, F, & SPIN TOP /R b Dusttight & Driptight Industrial Use SBTd SBRd.00 SBd / 7-/ 08 ST4d 4.00 SR4d 0.00 S4d SDTd onsult Schneider Electric at ( ) 7.00 SDRd.00 SDd onsult Schneider Electric at ( ) SERd SEd SFd b enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 6- for more information. c Limited to Pilot Light and Selector Switch or Start-Stop Push-Button. d oil voltage code must be specified to order this product. Refer to standard coil voltage codes listed on page 6-0. Dimensions page 6-4 Factory Modifications (Forms) page 6-0 Separate s (lass ) page 6- Replacement Parts (lass 8) page 6- S ccessories (lass ) page 6-8 For ow to Order Information, see page /DEFINITE PURPOSE TYPE 0 Schneider Electric P Discount 6-
5 Full Starters Style lass 86 / Refer to atalog 80T70 s SB SD With uxiliary Load Terminals It is sometimes desirable to use capacitors in motor branch circuits to improve power factor. The 0 SB SD starters listed below include three auxiliary terminals to allow easy connection of power factor correction capacitors. When capacitors are connected using these terminals, no adjustment to the selection of thermal units is necessary. The auxiliary terminals accept # 6 solid or stranded wire. & 4 starters have provisions for auxiliary connections. User must supply lugs as necessary. The S starters with auxiliary load terminals may also be used to control two motors simultaneously from a single starter. owever, this application is tightly restricted by Section - of the National Electrical ode. Refer to the NE for restrictions regarding overload protection, size of controller and motor branch circuit protection. Table 6.48: -Pole Polyphase Vac Maximum0 z Note that prices shown do not include thermal units. Devices require thermal units. Standard trip thermal units are $.0 each. See page Open SBTOa / 7-/ STOa 7.00 SDTOa.00 Extra apacity Starters (Not Style) -Pole 0 Vac Maximum0 z Table 6.4: Note that prices shown do not include thermal unit. Devices require thermal unit. Standard trip thermal unit is $.0 each. See page 6-6 Open R Rainproof, Sleet Resistant, Outdoor Use 4 & 4X Brushed Stainless Steel 4X Watertight orrosion Resistant lass-polyester /R c Dusttight and Driptight Industrial Use SDO8ab 4.00 SD8ab /DEFINITE PURPOSE TYPE 7-/ SEO6a 4.00 SE6a 7.00 SE6a 0.00 SEW6a SEW6a 6.00 SE6a 0.00 a oil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. b Uses a overload relay. c enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 6- for more information. Table 6.0: oil odes z 0 z 4d 0e ode V0 V0 V08 V0 V04 V06 V07 V. d 4 V coils are not available on s 4 7. On s 00, where 4 V coils are available, Form S (separate control) must be specified. e 0 Volt Polyphase starters are wired for separate control and must be ordered with Form S (i.e., 86SOV0S). Note: For voltage codes used with control transformers, see page 6-. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions page 6-4 Factory Modifications (Forms) page 6-0 Separate s (lass ) page 6- Replacement Parts (lass 8) page 6- S ccessories (lass ) page 6-8 For ow to Order Information, see page 6-. dder 6- Discount 0 Schneider Electric P
6 pplication Data for Selection Table 6.: Load Maximum Rating Nonplugging and Nonjogging Duty Full ontactors and Starters Style Maximum Rating Plugging and Jogging Duty a Rating, () Volt Service Limit Rating, () b Tungsten and Infrared Lamp Load, () 0 Volts c Resistance eating Loads, KW other than Infrared Lamp Loads d lass 80, 86 / Refer to atalog 80T70 KV Rating for Switching Transformer Primaries at 0 or ycles Ø Inrush s (Worst ase Peak)? 0 Times Peak of Rating Inrush s (Worst ase Peak) > 0 Times Peak of Rating Rating for Switching apacitors e KVR / -/ -/ -/ 0 P 4 6f / 7-/ 7-/ / -/ 00 7f Tables and footnotes are taken from Standards. -/ -/ -/ a shown are for applications requiring repeated interruptions of stalled motor current or repeated closing of high transient currents encountered in rapid motor reversal, involving more than five openings or closings per minute and more than ten in a tenminute period, such as plug-stop, plug-reverse or jogging duty. apply to single speed and multi-speed controllers. b Per Standards paragraph IS -.0, the service-limit current represents the maximum rms current, in mperes, which the controller may be expected to carry for protracted periods in normal service. t service-limit current ratings, temperature rises may exceed those obtained by testing the controller at its continuous current rating. The ultimate trip current of over-current (overload) relays or other motor protective devices shall not exceed the service-limit current ratings of the controller. c FLUORESENT LMP LODS00 VOLTS ND LESSThe characteristics of fluorescent lamps are such that it is not necessary to derate lass 80 contactors below their normal continuous current rating. lass 8 contactors may also be used with fluorescent lamp loads. For controlling tungsten and infrared lamp loads, and resistance heating loads, lass 8 lighting contactors are recommended. These contactors are specifically designed for such loads and are applied at their full rating as listed in the lass 8 Section. d apply to contactors which are employed to switch the load at the utilization voltage of the heat producing element with a duty which requires continuous operation of not more than five openings per minute. lass 8 s L and S lighting contactors are rated for resistance heating loads. e When discharged, a capacitor has essentially zero impedance. For repetitive switching by a contactor, sufficient impedance should be connected in series to limit inrush current to not more than 6 times the contactor rated continuous current. In many installations, the impedance of connecting conductors may be sufficient for this purpose. When switching to connect additional banks, the banks already on the line may be charged and can supply additional available short-circuit current which should be considered when selecting the impedance to limit the current. 7-/ The ratings for capacitor switching above assume the following maximum available fault currents: 00 :,000 RMS Sym. 4 :,000 RMS Sym. 6: 8,000 RMS Sym. 7: 0,000 RMS Sym. Note: If available fault current is greater than these values, connect sufficient impedance in series as noted in the previous paragraph. f For 6 & 7, the operation rate is as follows: operation rate is operations per minute maximum; Jogging or Plugging Duty operation rate is operations per minute for a maximum of three minutes. The motor ratings in Table 6. are standard ratings and apply only when the code letter of the motor is the same as or occurs earlier in the alphabet than is shown in the Table 6.. s having code letters occurring later in the alphabet may require a larger controller. onsult Schneider Electric at ( ). Table 6.: Rating -/ 7-/ and above Maximum llowable ode Letter L K 6 /DEFINITE PURPOSE TYPE 0 Schneider Electric 6-
7 Full ontactors and Starters Style pproximate Dimensions Table 6.: Dimensions for lass 80 Open of Poles Fig. DimensionsInches (Refer to ppropriate Figure) B D E F I lass 80, 86 / Refer to atalog 80T70 IN IN IN IN IN IN IN IN IN (lb) 00 SO -7/ 4-/ 4-7/ -/8 -/8 7/ -/6 4 0 SBO -7/ 4-/ 4-7/ -/8 -/8 7/ -/6 4 SO 4 4-/4 4-/ 4-7/ -/8 -/8 7/ -/6 4-/ SDO SEO 4 SFO 4-/6 -/8 4-/6 -/ -/ 7/ 4-/ 7/ -/6 6-/4 4 -/8 -/8 4-/6 -/ -/ 7/ 4-/ 7/ -/6 8-/4 -/ 7-/ 6-/ -7/8-7/ /6 6-/ -/4 4-/ /4 7-7/8 6-/ -/6 -/6 / / -/6 6 8-/6 6-/ -/6 -/6 /6 7 -/ -/ /4 8-/6 6-/ -/6 -/6 / / -/6 SO 8-/ -/6 8-/4 -/4 -/6 /8 -/8 4-/4 7-/4 4 6 SO -/64 8-/6-7/ 7-/ -/6 8-/6 4-/4 7-/ SJO -/64 7-/4-7/8-7/ 7-/ 7-7/ -/8 4-/4 7-/4 Table 6.4: Dimensions for 86 Open 00, 0,, P 0, SO SO SBO SO SDO SEO 4 SFO of Poles Fig. DimensionsInches (Refer to ppropriate Figure) B D E F I IN IN IN IN IN IN IN IN IN (lb) -/ 6-4/64 4-7/ / -/64 /64 6-/4 -/ 4 4-7/ 6-4/64 4-7/ / -/ /64 6-/4 -/ -/ 4-/6 7-/6 4-/6 / -/ /64 7-/ 4-/6 7-/4 4 -/8 7-/6 4-/6 / -/ /64 7-/ 4-/6 -/4 -/ -/ 6-/ 7/8 -/4 -/ /6 -/6 -/ /4 -/8 6-/ -/6 -/4 -/6 /6 -/6 -/4 6-7/8 6-/ -/6 -/4 -/6 /6 -/6 -/4 4 -/4-7/8 6-/ -/6 -/4 -/ /6 -/6 -/4 SO 8-/6 7-/6 8-/4 4-/4 7-/4 -/ /8 6-/ SO -/ 8-/6 4-/4 7-/4 -/ -/6 8-/6 8-/6 8 7 SJO -/ 7-/4-7/8 4-/4 7-/4 -/ 7-7/ -/8 Table 6.: Dimensions for 00 0 S SB S of Poles ll ll ll Fig. B DimensionsInches D E F I J K L 6 -/ -/6 7/8 8-/8 /6 4-/8 SD ll 7-/6 -/6 6-/ 6-/6 -/ -/ -/ -/ -/8 -/4 -/ -/8 SE ll -7/6 -/6 8 8-/8-7/ 8-/4-7/ -7/ 8-/8 7-/4-7/ 8-/8 4 SF ll -/4 -/ 8-/ -/4 -/4 -/6-7/6 7/6 S ll 7-7/ 44-7/ -/6 -/6 -/8 -/8 -/8 /6 6 S ll 4 6-/4 0-7/ -/8 -/8 64-/ -/6 -/ 7 SJ ll 4 4-/ -/ -/ Floor Mounting Wt Wt D E I RESET D E F F B B Figure lass 80 D K L K E RESET I B E Figure lass 86 F B Figure Pilot Light I J () losing Plates F 6 Figure 4 /DEFINITE PURPOSE TYPE E RESET (4) I Dia. Mtg. oles B D F Figure Schneider Electric
Numbering System Contactors NEMA Rated. Duplex Motor Starters Class Enclosures Class
Table of Contents Section 6 Contactors and Starters Manual Starters and Switches (p. 6-) Definite Purpose Contactors and Starters (p. 6-76) Rated S Contactors and Starters (p. 6-) C Magnetic Contactors
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationType S Contactors and Starters
Type S Contactors and Starters Class 8536/8502/8736/8702/8810/8811/8812 CONTENTS Description Page Magnetic Contactors and Starters.......................................1 Reversing Magnetic Starters and
More information28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description
.1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is
More informationOpen, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts
0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationJune 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]
7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationWell-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940
Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................
More informationPump Panel Specifications
Technical Data Pump Panel Specifications Bulletin Numbers 13 and 133 Topic Page Specifications Electrical Ratings (Bulletins 13, 13X, 133, 133X) Mechanical Ratings (Bulletins 13, 13X, 133, 133X) 3 Construction
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationManual Starters and Switches Integral Horsepower Types M and T
CLASS 510, 511, 51 INTEGRAL HORSEPOWER STARTERS TYPES M AND T Application Data Types M and T integral horsepower manual starters provide convenient On-Off operation of small single phase, polyphase, or
More informationMAGNETIC MOTOR STARTERS
Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors
More informationTABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:
3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches
More information4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors
.2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in
More informationand Refrigeration Institute). CNX Special Purpose Contactors
Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationNEMA Contactors & Starters A200
March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product
More informationECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters
ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,
More informationTDX - Taco Duplex Starter with
Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload
More informationCerti cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic
Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationSTC Starting Torque Controller A Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3
7 Bulletin 150 Reduced Voltage Starters Section Overview STC Starting Torque Controller 11 22 Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3 SMC-2 Smart Motor
More informationMotor Protection. Voltage Unbalance & Single-Phasing
For Summary of Suggestions to Protect Three-Phase Motors Against Single-Phasing see the end of this section, page 137. Historically, the causes of motor failure can be attributed to: Overloads 30% Contaminants
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationOverview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8
Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical
More informationMini Contactors CI 4-
Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they
More informationMotor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors
Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationTechnical data OT16E3 OT160E3 UL & CSA
Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58
More informationTechnical Information
Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationE C N A A F -
33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40
More informationSprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures
Enclosed ontactors Sprecher + Schuh s popular contactor lines housed in a variety of enclosures Sprecher + Schuh s broad line of E/UL HP rated contactors can be purchased pre-installed in a variety of
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationContactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents
Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -
More informationMOTOR TERMINAL CONNECTIONS
MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors
More informationSeries CA5 Contactors
Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More informationNEMA Contactors and Starters
NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationVariable Frequency AC Motor Drive Units
14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationSoftstarters. Softstarters Power electronic brakes Type PEB
Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationNEMA Contactors and Starters
NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................
More information.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th
NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................
More informationDesigned for ease of integration with automation systems
BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from
More information209 Series. Magnetic Circuit Protectors
29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279
More informationA compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.
PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9
February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationMATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation
MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation
More informationAP/UP, AP/MIL Series Magnetic Circuit Protectors
AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables
More information48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp
48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp E13224 The 48 series is a contactor with a 4 normally open, double make contacts rated up to 3HP. It uses a solenoid type moving core design
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload
More informationGeneral + Definite Purpose Contactors
General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross
More informationSpecifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)
Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationCL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES
SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationNEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1
NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationPump Panels Type 3R Enclosure
Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationType E/F Simplex & Duplex Pump Controllers
Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping
More informationNQOD Circuit Breaker Panelboards
NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationDirect On Line (DOL) Motor Starter. Direct Online Motor Starter
Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.
More informationAir-insulated switchgear UniGear type ZS1
Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More information