1 Submersible Motor Pump maporter Lenntech Tel Fax Type Series ooklet
2 Legal information/opyright Type Series ooklet maporter ll rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KS ktiengesellschaft, Frankenthal
3 ontents ontents uilding Services: Drainage maporter...5 Main applications... 5 Fluids handled... 5 Operating data...5 Designation... 5 Design details... 5 oating and preservation...6 Materials...6 Product benefits... 6 ertifications... 6 Overview of range... 7 Technical data... 8 maporter 5, F impeller... 8 maporter 6, F impeller... 8 maporter S 545, S impeller...9 haracteristic curves...10 maporter 5 ; n = 2900 rpm; F impeller maporter 6 ; n = 2900 rpm; F impeller maporter S 545; n = 2900 rpm; S impeller... Dimensions maporter 5, F impeller, transportable wetinstalled model maporter 6, F impeller, transportable wetinstalled model maporter S 545, S impeller, transportable wetinstalled model maporter 5, F impeller, stationary wetinstalled model with guide wire/guide hoop, duckfoot bend DN /...15 maporter 6, F impeller, stationary wetinstalled model with guide wire/guide hoop, duckfoot bend DN 65/ maporter S 545, S impeller, stationary wetinstalled model with guide wire/guide hoop, duckfoot bend DN /...16 maporter 5, F impeller, stationary wetinstalled model with guide wire/guide hoop, straight pump foot G 2" maporter 6, F impeller, stationary wetinstalled model with guide wire/guide hoop, straight pump foot G 2½" maporter S 545, S impeller, stationary wetinstalled model with guide wire/guide hoop, straight pump foot G 2" maporter 5, F impeller, stationary wetinstalled model with single guide rail, duckfoot bend DN / maporter 6, F impeller, stationary wetinstalled model with single guide rail, duckfoot bend DN 65/ maporter S 545, S impeller, stationary wetinstalled model with single guide rail, duckfoot bend DN / maporter 5, F impeller, stationary wetinstalled model with single guide rail, straight pump foot G 2" maporter 6, F impeller, stationary wetinstalled model with single guide rail, straight pump foot G 2 ½"... 3
4 ontents maporter S 545, S impeller, stationary wetinstalled model with single guide rail, straight pump foot G 2"... maporter 5, F impeller, stationary wetinstalled model with twin guide rails, duckfoot bend DN / maporter 6, F impeller, stationary wetinstalled model with twin guide rails, duckfoot bend DN 65/ maporter S 545, S impeller, stationary wetinstalled model with twin guide rails, duckfoot bend DN / Sump maporter 5 /6, F impeller / maporter S 545, S impeller Information on installation Suggested electrical installation layouts...23 Scope of supply ccessories Installation parts for stationary and transportable pump sets...25 hain for stationary and transportable pump sets Pump accessories ontrol units and switchgear larm switchgears for pumps without TEX...29 ontrol unit/switchgear accessories larm switchgear models
5 uilding Services: Drainage uilding Services: Drainage ode Description Starting aid 1) Without start capacitor With start capacitor Size 5 DN 6 DN 65 Impeller size Motor version SE Singlephase motor with float switch NE Singlephase motor without float switch ND Threephase asynchronous motor without float switch 5 maporter 01 SE Design details Design Fully floodable submersible motor pump losecoupled design Vertical installation Singlestage Installation types Wetinstalled stationary pump sets Wetinstalled transportable pump sets Shaft seal Drive end Main applications Drainage systems Water extraction Drainage Shaft seal ring Pump end 1 bidirectional mechanical seal with liquid reservoir Impeller type Fluids handled Freeflow impeller (impeller type F) Suitable for the following fluids: fluids containing solids and stringy material as well as fluids with entrapped air or gas Impeller with cutter (impeller type S) Suitable for the following fluids: faeces, domestic sewage and waste water containing long fibres Grey water Waste water containing long fibres and solid substances Gascontaining fluids Operating data Operating properties haracteristic Flow rate Head Fluid temperature maporter maporter S Q 40 m3/h (11 l/s) 17 m3/h (4.7 l/s) H 16 m 21 m t max. +40 (+70 for short periods) Drive Singlephase motor Hz: 230 V With integrated temperature switch Designation Example: maporter S 545 SE Key to the designation ode Description maporter Type series S Impeller 1) F impeller S S impeller 1) Threephase asynchronous motor Hz: 400 V DOL starting Enclosure: IP68 (permanently submerged) to EN / IE 529 Thermal class of winding insulation: F earings Greaselubricated bearings sealed for life lank maporter 5
6 uilding Services: Drainage oating and preservation Primer and top coat Surface treatment: Top coat: Special coating lasted to S 2 1 / 2 to DIN EN ISO 944 Twocomponent highsolid epoxy resin finish (RL 02), min. layer thickness = 75 µm vailable on request (extra charge and a longer delivery period apply). Materials Overview of available materials omponent maporter 5 / 6 maporter S 545 asing JL 1030 F impeller JL 1030 JL 1040 utter 1.80 (K) Shaft Shaft seal Drive end Shaft seal ring olts and nuts Joint rings Float switch Pump end Product benefits Mechanical seal Si / L 2 O 3 2 Nitrile Polypropylene Mechanical seal Si / Si Easy and fast installation/removal with polarised, absolutely watertight cable and KS plug connection ensuring correct installation Motor absolutely watertight, also in the event of damage to the cable sheath and core insulation, with individually stripped, tinned and resinsealed conductors High operating reliability due to dry, pressuretight and encapsulated squirrelcage motor, thermal class F Threephase motor: protected against overheating even under tough operating conditions due to generously sized motor. motor: protected against overheating by thermal switches in the windings Long service life with shaft made of corrosionresistant stainless steel Increased reliability due to bidirectional mechanical seal Ease of service with wetted bolts made of stainless steel, which are easy to undo even after years of operation Troublefree operation: clogging by coarse particles is prevented by large free passage (freeflow impeller) or by cutter with high mechanical resistance for waste water Stationary pump sets easy to install and remove with automatic, boltfree connection; leakage prevented by elastic sealing elements ertifications Label Valid in: omment Europe Suitable for plants to Standard EN 01 Europe MW (test report) Nos.: to 05 6 maporter
7 uilding Services: Drainage Overview of range Standard variants Size F impeller S impeller maporter 5 / 6 maporter S 545 Motor version SE NE ND SE NE ND Number of motor poles 2pole Explosion protection Motor versions SE, NE, ND Not explosionproof Motor With start capacitor Starting method DOL 2) Voltage 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ ooling ooled by surrounding fluid Mode of operation S1 submerged (max. 10 m) Level measurement: with float switch Power cable Type Rubbersheathed cable H07RN8F 3x1² H07RN8F 4x1² Length 10 m 3) able entry bsolutely watertight Sealing elements Shaft seal Drive end: shaft seal ring Pump end: mechanical seal Elastomer seals NR Monitoring equipment Winding temperature Thermal motor protection Thermal motor protection oating Environmentally friendly KS top coat (twocomponent epoxy paint), colour RL 02, film thickness = 75 µm Installation Stationary, with guide hoop Installation depths 1.5 m/1.8 m/2.1 m Stationary, with single guide rail Installation depth 4.5 m Stationary, with twin guide rail Installation depth 4.5 m Stationary, with guide wire Installation depth 4.5 m Transportable Installation depth 4.5 m Maximum temperature of fluid handled Motor versions SE, NE, ND 40 2) Maximum switching frequency: 15 starts per hour 3) Optional: m maporter 7
8 uilding Services: Drainage Technical data maporter 5, F impeller Hz 1 ~ 230 V, 10 m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 0 SE 45 1,00 0,55 5,00 18,2 3 x 1, SE ,25 0,75 6,00 18,2 3 x 1, SE ,80 1,10 8, 18,2 3 x 1, SE ,80 1,10 8, 18,2 3 x 1, NE 45 1,00 0,55 5,00 18,2 3 x 1, NE ,25 0,75 6,00 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, Hz 1~ 230 V, m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 0 NE 45 1,00 0,55 5,00 18,2 3 x 1, NE ,25 0,75 6,00 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, Hz 3 ~ 400 V, 10 m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 0 ND 45 0,90 0,55 2,30 18,3 4 x 1, ND ,10 0,75 2,80 18,3 4 x 1, ND , 1,10 3,00 18,3 4 x 1, ND ,05 1, 3, 18,3 4 x 1, Hz 3 ~ 400 V, m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 0 ND 45 0,90 0,55 2,30 18,3 4 x 1, ND ,10 0,75 2,80 18,3 4 x 1, ND , 1,10 3,00 18,3 4 x 1, ND ,05 1, 3, 18,3 4 x 1, maporter 6, F impeller Hz 1 ~ 230 V, 10 m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 601 SE ,25 0,75 6,00 18,2 3 x 1, SE ,80 1,10 8, 18,2 3 x 1, SE ,80 1,10 8, 18,2 3 x 1, NE ,25 0,75 6,00 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, Hz 1 ~ 230 V, m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 601 NE ,25 0,75 6, 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, NE ,80 1,10 8, 18,2 3 x 1, maporter
9 uilding Services: Drainage Hz 3 ~ 400 V, 10 m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 601 ND ,10 0,75 2,80 18,3 4 x 1, ND , 1,10 3,00 18,3 4 x 1, ND ,05 1, 3, 18,3 4 x 1, Hz 3 ~ 400 V, m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] 601 ND ,10 0,75 2,80 18,3 4 x 1, ND , 1,10 3,00 18,3 4 x 1, ND ,05 1, 3, 18,3 4 x 1, maporter S 545, S impeller Hz 1 ~ 230 V, 10 m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] S 545 SE ,80 1,10 8, 18,2 4 x 1, S 545 NE ,80 1,10 8, 18,2 4 x 1, Hz 3 ~ 400 V, 10 m power cable Size Impeller Ø Free passage P 1 P 2 I N I Mains connection Mat. No. [kg] [mm] [mm] [kw] [kw] [] [] [mm 2 ] S 545 ND ,05 1, 3, 18,3 4 x 1, maporter 9
10 uilding Services: Drainage haracteristic curves maporter 5 ; n = 2900 rpm; F impeller haracteristic curves to ISO 9906 lass 2 / 3, below 10 kw to The curves refer to the effective motor speed Q [US.gpm] Q [IM.gpm] H [ft] 6 H [m] Q [m³/h] Q [l/s] KM05xx/0 Free passage: 0/1 = 45 mm, 2 = 43 mm, 3 = 41 mm 10 maporter
11 uilding Services: Drainage maporter 6 ; n = 2900 rpm; F impeller haracteristic curves to ISO 9906 lass 2 / 3, below 10 kw to The curves refer to the effective motor speed. 0 1 Q [US.gpm] 0 1 Q [IM.gpm] H [ft] 3 10 H [m] Q [m³/h] Q [l/s] KM6006xx/0 Free passage: 601 = 60 mm, 602 = 58 mm, 603 = 56 mm maporter 11
12 uilding Services: Drainage maporter S 545; n = 2900 rpm; S impeller haracteristic curves to ISO 9906 lass 2 / 3, below 10 kw to The curves refer to the effective motor speed Q [US.gpm] Q [IM.gpm] H [ft] 10 S 545 1~ H [m] S 545 3~ 0 2 Q [m³/h] Q [l/s] KS_545/0 Free passage = 7 mm maporter
13 uilding Services: Drainage Dimensions maporter 5, F impeller, transportable wetinstalled model Ø63 (2) (1) 60 R=160 R DNPN6 (1) Lowest switchoff point (2) Hose inner diameter: 63 mm maporter 6, F impeller, transportable wetinstalled model 8 1 Ø80 (2) (1) 408 R= Ø Ø18 DN65PN16 (1) Lowest switchoff point (2) Hose inner diameter: 80 mm maporter 13
14 uilding Services: Drainage maporter S 545, S impeller, transportable wetinstalled model (2) R = 160 (1) G R DNPN6 (1) Lowest switchoff point (2) Hose inner diameter: 63 mm 14 maporter
15 uilding Services: Drainage maporter 5, F impeller, stationary wetinstalled model with guide wire/guide hoop, duckfoot bend DN / ISO 7005 PN 16 DN PN 16 SME (3) (1) D DN PN (a) (b) (2) 80 D (1) Lowest switchoff point (a) Minimum (2) Guide hoop (b) Maximum (3) Flange of duckfoot bend maporter 6, F impeller, stationary wetinstalled model with guide wire/guide hoop, duckfoot bend DN 65/ ISO 7005 PN 16 DN 65 PN 16 SME 2 1 / (1) 74 D DN65 PN (a) (b) (2) 79 D (3) (1) Lowest switchoff point (a) Minimum (2) Guide hoop (b) Maximum (3) Flange of duckfoot bend maporter 15
16 uilding Services: Drainage maporter S 545, S impeller, stationary wetinstalled model with guide wire/guide hoop, duckfoot bend DN / ø10 (2) ISO 7005 PN 16 DN PN 16 SME (3) 138 (1) D 148 ø DN PN 16 SME (a) (b) 79 D (1) Lowest switchoff point (a) Minimum (2) Guide hoop (b) Maximum (3) Flange of duckfoot bend maporter 5, F impeller, stationary wetinstalled model with guide wire/guide hoop, straight pump foot G 2" (2) 400 D (1) DN G 2 (a) (b) D (1) Lowest switchoff point (a) Minimum (2) Guide hoop (b) Maximum 16 maporter
17 15 5 uilding Services: Drainage maporter 6, F impeller, stationary wetinstalled model with guide wire/guide hoop, straight pump foot G 2½" (1) D DN G2 1 / 2 (a) (b) (2) 79 D (1) Lowest switchoff point (a) Minimum (2) Guide hoop (b) Maximum maporter S 545, S impeller, stationary wetinstalled model with guide wire/guide hoop, straight pump foot G 2" ø (2) 400 (1) D DN G2 D (a) (b) (1) Lowest switchoff point (a) Minimum (2) Guide hoop (b) Maximum maporter 17
18 uilding Services: Drainage maporter 5, F impeller, stationary wetinstalled model with single guide rail, duckfoot bend DN / ISO 7005 PN 16 DN PN 16 SME Ø33,5 x2 130 (2) DN PN (1) (1) Lowest switchoff point (2) Flange of duckfoot bend maporter 6, F impeller, stationary wetinstalled model with single guide rail, duckfoot bend DN 65/ ISO 7005 PN 16 DN 65 PN 16 SME 2 1 / Ø33,7 x 2 1 (2) DN65 PN (1) (1) Lowest switchoff point (2) Flange of duckfoot bend 18 maporter
19 uilding Services: Drainage maporter S 545, S impeller, stationary wetinstalled model with single guide rail, duckfoot bend DN / ø10 ISO 7005 PN 16 DN PN 16 SME Ø 33.7 x (2) (1) ø DN PN 16 SME (1) Lowest switchoff point (2) Flange of duckfoot bend maporter 5, F impeller, stationary wetinstalled model with single guide rail, straight pump foot G 2" Ø33,7 x (1) DN G (1) Lowest switchoff point maporter 19
20 uilding Services: Drainage maporter 6, F impeller, stationary wetinstalled model with single guide rail, straight pump foot G 2 ½" Ø33,7 x (1) DN G 2 1 / (1) Lowest switchoff point maporter S 545, S impeller, stationary wetinstalled model with single guide rail, straight pump foot G 2" Ø33,7 x (1) DN G (1) Lowest switchoff point maporter
21 uilding Services: Drainage maporter 5, F impeller, stationary wetinstalled model with twin guide rails, duckfoot bend DN / E E Ø 33,7 x 2 D (a) D (a) Ø480 (a) (1) DN 0 Ø5 DN PN10PN16 Ø0,5 SME 1 2 ISO 7005 PN10PN16 DIN 21 PN10PN16 SME DN (2) 0 (1) Lowest switchoff point (a) Minimum (2) Flange of duckfoot bend maporter 6, F impeller, stationary wetinstalled model with twin guide rails, duckfoot bend DN 65/65 E E 76 D 530 (a) 8 Ø530 (a) D Ø 33,7 x (a) (1) DN ISO 7005 PN10PN16 DIN 21 PN10PN16 DN 65/65 Ø (2) SME / 2 DN 65/65 Ø (1) Lowest switchoff point (a) Minimum (2) Flange of duckfoot bend maporter 21
22 uilding Services: Drainage maporter S 545, S impeller, stationary wetinstalled model with twin guide rails, duckfoot bend DN / E E ø10 D (a) ø 480 (a) 5 D 431 Ø 33.7 x (a) (1) ø DN 0 ø5 DN PN10PN16 ø0.5 SME 1 2 ISO 7005 PN10PN16 DIN 21 PN10PN16 SME (2) (1) Lowest switchoff point (a) Minimum (2) Flange of duckfoot bend Sump maporter 5 /6, F impeller / maporter S 545, S impeller (1) Minimum (2) ON (3) OFF Size D maporter x maporter x maporter S x (2) D (1) (3) x (1) 22 maporter
23 uilding Services: Drainage Information on installation Suggested electrical installation layouts maporter is available in nonexplosionproof design. maporter 5 / 6 E E51 E52 E53 E4 E10, E11 E13, E14 E16, E17 E18, E19 E60 E60 Suggested installation layout No. 1 Suggested installation layout No. 2 maporter S 545 E E51 E52 E53 E E10, E11 E13, E14 E16, E17 E18, E19 E60 E60 Suggested installation layout No. 1 Suggested installation layout No. 2 maporter 23
24 uilding Services: Drainage Scope of supply Depending on the model, the following items are included in the scope of supply: Duckfoot bend with mounting elements Guiding accessories (guide rails are not included in KS's scope of supply) Stationary wetinstalled model (installation type S) Pump set, complete with power cable law with sealing element (Oring) and mounting elements Lifting chain 4) Mounting bracket with mounting elements Transportable wetinstalled model (installation type P) Pump set, complete with power cable Installation parts for transportable version, comprising: three feet, connection elbow, connection piece and clamp Lifting chain 5) 4) Optional 5) Optional 24 maporter
25 uilding Services: Drainage ccessories Installation parts for stationary and transportable pump sets Overview of installation parts for stationary and transportable pump sets Item Description onnection Installation depth P2 + P5 P2 + P5 P2 + P5 P2 + P5 P4 + P5 P4 + P5 P4 + P5 P4 + P5 P4 + P5 Installation parts for stationary wet installation (guide hoop arrangement) onsisting of: DN flanged duckfoot bend, guide hoop, anchor bolts, claw with stainless steel screws/bolts Installation parts for stationary wet installation (guide hoop arrangement) onsisting of: DN 65 flanged duckfoot bend, stainless steel anchor bolts, guide hoop, claw with stainless steel screws/bolts Installation parts for stationary wet installation (guide hoop installation) onsisting of: DN /2" flanged duckfoot bend, guide hoop, claw with stainless steel screws/bolts Installation parts for stationary wet installation (guide hoop installation) onsisting of: DN 65/2½" flanged duckfoot bend, guide hoop, claw with stainless steel screws/bolts Installation parts for stationary wet installation (guide wire installation) onsisting of: flanged duckfoot bend, suspension bracket, mounting bracket, 10 m guide wire, screws, bolts, anchor bolts, claw with stainless steel screws/bolts Installation parts for stationary wet installation (guide wire installation) onsisting of: flanged duckfoot bend, suspension bracket, mounting bracket, 10 m guide wire, claw with stainless steel screws/ bolts Installation parts for stationary wet installation (single guide rail arrangement) onsisting of: flanged duckfoot bend, mounting bracket, claw with stainless steel screws/bolts (guide rails not included in KS's scope of supply) Installation parts for stationary wet installation (guide rail installation) onsisting of: flanged duckfoot bend, mounting bracket, claw with stainless steel screws/bolts (guide rails not included in KS's scope of supply) Installation parts for stationary wet installation (twin guide rail arrangement) onsisting of: flanged duckfoot bend, stainless steel anchor bolts, mounting bracket, adapter, claw with stainless steel screws/bolts (guide rails not included in KS's scope of supply) maporter Mat. No. [kg] 5 6 S 545 DN 1,5 m DN 1,8 m DN 2,1 m DN 65 1,5 m DN 65 1,8 m DN 65 2,1 m DN /2" 1,5 m DN /2" 1,8 m DN /2" 2,1 m DN 65/2½" 1,5 m DN 65/2½" 1,8 m DN 65/2½" 2,1 m DN 4,5 m DN 65 4,5 m DN / 2" 4,5 m DN 65 / 2½" 4,5 m DN 4,5 m DN 65 4,5 m DN / 2" 4,5 m DN 65 / 2½" 4,5 m DN, DN 3: DIN ISO SME DN 65, DN 3: DIN ISO SME 4,5 m ,5 m P6 Kit for transportable models Includes: adapter for hose connection, connection elbow, three feet, hose clip including bolts DN (plastic hose inner ø 63 P19) maporter 25
26 uilding Services: Drainage Item Description onnection Installation depth Only for S 545 P5 law JL1040 with stainless steel bolts Guide wire, single guide rail, guide hoop arrangement law JL1040 with stainless steel bolts Twin guide rail arrangement Mat. No. [kg] DN DN DN 65 P5 (plastic hose inner ø 63 P19) (plastic hose inner ø 80 P19) maporter 5 6 S Parts for conversion to twin guide rail DN /DN arrangement, consisting of: mounting bracket, 65 stainless steel screws/bolts, adapter, anchor bolts hain for stationary and transportable pump sets Overview of chains for stationary and transportable pump sets Item Description P7 Length hain (1.4404) shortlinked, tested and duly labelled to Directive 06/42/E (Machinery Directive), hook (1.4301), shackle (1.4404) Maximum load: 160 kg 2m 3m 5m 10 m maporter 5 6 S 545 Mat. No. [kg] Pump accessories Overview of accessories Item Description P8 DN /R2" pipe DN 65/R2½" pipe DN /Rp 2 maporter Mat. No. [kg] 5 6 S P10 Threaded flange PN 6, DIN 2558 with screws/ bolts for pump discharge nozzle P14 Elbow with internal/external thread (to be used for G 2" flange connections with item 27), galvanised grey G 2½" cast iron Storz rigid coupling with flange, to DIN 21, DN 65/ 75 drilled to PN 16 (to be used for flange connections item 25), aluminium/steel 2 hose clips, item, are required for hose 75 (DIN mounting (for plastic hoses 75, item 19) 14322) Storz rigid coupling with external thread, DIN ISO 228/1 52/G G 2½ P15 P16 P17 26 Flange for pipe coupling PN 10, at the flanged elbow, mating dimensions to PN 16 onnection Length maporter
27 uilding Services: Drainage Item Description P18 Plastic hose DN, DIN 14811, with integrated couplings P19 Plastic hose Without coupling, DIN P Hose clip DIN 3017, chrome steel onnection Length 525 m maporter Mat. No. [kg] 5 6 S m m Inside 5m diameter m m 75 5m 10 m m 30 m P21 RK swing check valve Rp 2 P22 Plastic, EN 04, with internal thread ISO 7/1, full port and drain plug; cannot be used for pumped drainage Socket gate valve uzn PN 10 DIN 3352 Rp Rp 2½ P23 KS check valve, grey cast iron With full port, backwash device, flanges drilled to DIN 21, PN 16 (not for lifting units) DN P24 EOLINE GTR16P gate valve, grey cast iron, PN 16, DN 65 flanges drilled to ISO 7005/DIN P25 Set of installation accessories for a flange connection, discharge nozzle; items 14 or 15 onsisting of: 4 hexagon head bolts with nuts and 1 sealing element Threaded flange PN 16/2", threaded connection DN /Rp 2 DIN 2566 with screws/bolts, sealing element DN 65/Rp and nuts for flanged bend 2½ P27 P28 onsisting of: flange, 4 hexagon head bolts with nuts and discs, and 1 sealing element Suction strainer maporter 27
28 uilding Services: Drainage ontrol units and switchgear Valid for all countries except France Overview of control units and switchgear Item Description Type maporter Mat. No. [kg] E1 E2 E4 E10 E11 E 13 E 14 E 16 E 17 E 18 E 19 E30 E 33 E 34 E 36 E 37 E 38 E 39 Motor protection switchgear MSE 230 V 400 V Float switch MSE MSE MSE Motor protection switchgear Float switch MSD MSD MSD Multifunctional plug, type Hyper, with motor Hyper protection relay Hyper Levelontrol asic 2 control unit for singlepump station, IP54 For float switch or 4... m sensor, optional master switch, 400 x 278 x 0 mm Pneumatic, optionally with 400 x 278 x 0 mm master switch ubbler control, with 400 x 300 x 155 mm master switch ubbler control for version Only to be used for connections with neutral conductor! Installation option O1 (master switch) not possible! 400 x 281 x 0 Levelontrol asic 2 control unit for dualpump station, IP 54 For float switch or 4... m sensor, optional master switch, 400 x 278 x 0 mm Pneumatic, optionally with 400 x 278 x 0 mm master switch ubbler control, with 400 x 300 x 155 mm master switch ubbler control for version Only to be used for connections with neutral conductor! Installation option O1 (master switch) not possible! 400 x 281 x 0 mm DFNO DFNO DFNO DPNO DPNO DPNO S1 230 DLNO S1 400 DLNO S1 400 DLNO DLNO DLNO DLNO DFNO DFNO DFNO DPNO DPNO DPNO S2 230 DLNO S2 400 DLNO S2 400 DLNO DLNO DLNO DLNO S 545 Valid for France! Overview of control units and switchgear Item Description Type maporter Mat. No. [kg] 230 V 400 V E1 Motor protection switchgear MSE Float switch MSE MSE MSE E2 Motor protection switchgear MSD Float switch MSD MSD E4 E10 E11 E30 Multifunctional plug, type Hyper, with motor Hyper protection relay Hyper Levelontrol asic 2 control unit for singlepump station, IP 54 For float switch or 4... m sensor, optional DFNM master switch, 400 x 278 x 0 mm, DFNM For float switch or 4... m sensor, optional DFNO master switch, 400 x 278 x 0 mm, DFNO Levelontrol asic 2 control unit for dualpump station, IP 54 For float switch or 4... m sensor, optional master switch, 400 x 278 x 0 mm DFNM DFNM S maporter
29 uilding Services: Drainage Item Description Type maporter Mat. No. [kg] E31 For float switch or 4... m sensor, optional master switch, 400 x 278 x 0 mm 230 V 400 V DFNO DFNO S 545 Levelontrol asic 2 installation options (processed via KS EasySelect) 6) Item Description maporter Mat. No. [kg] O1 Master switch for Levelontrol asic 2, installed for type O2 ontrol cabinet heating, installed for type S O10 Outdoor cabinet type 142 with integrated base for control unit Dimensions W x H x D [mm]: 3 x 14 x 225 O11 Outdoor cabinet type 0/845 for control units S1 (up to 25 ) and S2 (up to 10 ) Dimensions W x H x D [mm]: 585 x 845 x O0 Signalling module for type O1 Signalling module for type, With pressure sensor 3 mlc for redundant pneumatic level measurement or redundant bubbler system O3 Signalling module for type S O4 Signalling module for type S..., With pressure sensor 3 mlc for redundant pneumatic level measurement or redundant bubbler system S 545 larm switchgears for pumps without TEX S 0/S 1/S 2/S 4/S 5 Item Description Mat. No. [kg] E larm switchgear S 0 with circuit breaker, piezoceramic signal transmitter, 85 d() at a distance of 1 m and 4.1 khz, green equipmenton lamp Plastic housing IP, 140 x 80 x 57 mm. Use float switch, F1 moisture sensor (item E64), M1 alarm contactor or signal relay of control unit as contactor. E51 larm switchgear S 2 with circuit breaker, piezoceramic signal transmitter, 85 d() at a distance of 1 m and 4.1 khz, green equipmenton lamp, voltfree contact for hookup to a control station. Plastic housing IP, 140 x 80 x 57 mm. Use float switch, F1 moisture sensor (item E 64) or signal relay of control unit as contactor. E52 larm switchgear S 4 with circuit breaker, piezoceramic signal transmitter, 85 d() at a distance of 1 m and 4.1 khz, green equipmenton lamp, voltfree contact for hookup to a control station, selfcharging power supply unit for 5 hours' operation in the event of power failure Plastic housing IP, 140 x 80 x 57 mm. Use float switch (E60), F1 moisture sensor (item E64) or signal relay of control unit as contactor ) Installation options must be processed via KS EasySelect, otherwise they will be supplied with the unit but not fitted. maporter 29
30 uilding Services: Drainage Item Description Mat. No. [kg] E53 larm switchgear S 5 Mainsindependent, with selfcharging power supply unit for 10 hours' operation in the event of power failure, mains pilot LED, fault indicator light, hornoff push button, voltfree contact for hookup to a control station, ready for connection with 1.8 m connection cable and plug. In ISO plug housing IP30, mainsindependent, with selfcharging power supply unit for 5 hours operation in the event of a power failure, acoustic signal 70 d() with circuit breaker and integrated signal transmitter with 3metre connection cable, max. 60, not suitable for steam and condensate. 1. High water alert by suspending the moisture sensor in a (pump) sump above the pump startup point. 2. Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in the kitchen or bathroom ISO housing IP41, 190 x 165 x 75 mm. Use float switch (E60) or signal relay of control unit as contactor. E55 larm switchgear S ontrol unit/switchgear accessories Item Description maporter Mat. No. [kg] S 545 E60 Float switch with free cable end (NO contact) 3 m m m m m m m E62 Float switch with free cable end (N contact) 5 m m m E64 Leakage sensor F 1 3 m E65 E66 Open pressure bell set pneumatic and bubbler control with polyamide tube 8 x 1 mm losed pressure bell set pneumatic with polyamide tube 8 x 3 mm Tube length 10 m Tube length m Tube length m Tube length 10 m Tube length > 10 m E70 Horn, V D, 105 d, 1 m, IP54, 2 strands of 0.45 m length E71 larm combination, V D E72 Yellow alarm strobe light, V D, 195 m, IP E73 P service tool E90 Rechargeable battery retrofit kit for Levelontrol asic 2, for powering the electronics, the float switches of the level sensors or the internal pressure sensor and the alarm equipment (buzzer, horn, alarm combination), for singlepump and dualpump stations For type, includes 2 rechargeable batteries 6 V, 1.3 h and charging unit For type S, consisting of 1 rechargeable battery V, 1.2 h and charging unit maporter
31 uilding Services: Drainage larm switchgear models larm switchgear models for singlepump stations Feature Design Float switch Pneumatic ubbler control bubbler control 230 V: 6,0 10, DFNO DPNO S1 230 DLNO DLNO 400 V: 2,5 4, DFNO DPNO 040 S1 400 DLNO DLNO V: 4,0 6, DFNO DPNO 063 S1 400 DLNO DLNO 063 Functions Tank drainage Tank filling via float switch Peak load operation function Standby pump: 1 pump redundant utomatic pump changeover after every start utomatic pump changeover in the case of a pump fault Runtime limitation OFF via afterrun time OFF via level Operation check run after idle period lert memory Display and operation 7segment display Indication of water level Switching points For each pump: operation/fault/pump Multicolour LED Multicolour LED Multicolour LED Multicolour LED running General fault (traffic light) LED LED LED LED High water LED LED LED LED Mains voltage Mains frequency Motor current per pump Operating hours of each pump Operating hours of the system Starts per pump Effective power per pump Rotary field recognition of mains power supply Phase monitoring hange of switching level via control panel Housing H x W x D, IP 54 Plastic 400 x 278 x 0 Sheet steel 400 x 300 x 155 uiltin components Master switch (lockable) o o Manual0automatic selector switch per pump DOL starting Shockproof socket 230 V t 230 V t 230 V t 230 V t 230 V Motor protection Fuse per pump t 230 V t 230 V t 230 V t 230 V Motor protection switch per pump t 400 V t 400 V t 400 V t 400 V (overcurrent and shortcircuit protection) Motor temperature warning input selfacknowledging Motor temperature alert input manual acknowledgement Pump Thermal circuit breaker (T) / bimetal switch 7) 7) 7) 7) per pump Installation options Rechargeable battery for powering the o o o o electronics, sensors, alarm equipment ontrol cabinet heating, type S o at 400 V larm equipment 7) maporter NE 1 ~ 230 V: bimetal switch in the motor; maporter ND 3 ~ 400 V: no bimetal switch maporter 31
32 uilding Services: Drainage Feature Design Float switch Pneumatic ubbler control bubbler control 1 free alarm input 1 digital high water alert input (e.g. for float switch) Voltfree contact (changeover contact) for general fault/operation message Piezo buzzer 85 d() Horn 105 d() / alarm combination / alarm o o o o strobe light V D Inputs/outputs Inputs for float switches m analog input Integrated pneumatic pressure sensor up to 3 metres of water up to 10 metres on request ubbler system with compressor up to 2 metres of water Remote acknowledgement V D connection for horn, alarm combination, alarm strobe light Sensors Float switch (NO contact) o Redundant float switch (NO contact) for high o o o water Pressure bell (open system) for pneumatic and o o o bubbler control system Pressure bell (closed system) for pneumatic o system F1 moisture sensor o o o Tools KS Service Tool for Windows XP o o o o Key to the symbols Symbol Description o Optional vailable Not available 32 maporter
33 uilding Services: Drainage larm switchgear models for dualpump stations Feature Design Float switch Pneumatic ubbler control bubbler control 230 V: 6,0 10, DFNO DPNO S2 230 DLNO DLNO 400 V: 2,5 4, DFNO DPNO 040 S2 400 DLNO DLNO V: 4,0 6, DFNO DPNO 063 S2 400 DLNO DLNO 063 Functions Tank drainage Tank filling via float switch Peak load operation function Standby pump: 1 pump redundant utomatic pump changeover after every start utomatic pump changeover in the case of a pump fault Runtime limitation OFF via afterrun time OFF via level Operation check run after idle period lert memory Display and operation 7segment display Indication of water level Switching points For each pump: operation/fault/pump Multicolour LED Multicolour LED Multicolour LED Multicolour LED running General fault (traffic light) LED LED LED LED High water LED LED LED LED Mains voltage Mains frequency Motor current per pump Operating hours of each pump Operating hours of the system Starts per pump Effective power per pump Rotary field recognition of mains power supply Phase monitoring hange of switching level via control panel Housing H x W x D, IP 54 Plastic 400 x 278 x 0 Sheet steel 400 x 300 x 155 uiltin components Master switch (lockable) o o Manual0automatic selector switch per pump DOL starting Shockproof socket 230 V t 230 V t 230 V t 230 V t 230 V Motor protection Fuse per pump t 230 V t 230 V t 230 V t 230 V Motor protection switch per pump t 400 V t 400 V t 400 V t 400 V (overcurrent and shortcircuit protection) Motor temperature warning input selfacknowledging Motor temperature alert input manual acknowledgement Pump Thermal circuit breaker (T) / bimetal switch 8) 8) 8) 8) per pump Installation options Rechargeable battery for powering the o o o o electronics, sensors, alarm equipment ontrol cabinet heating, type S o at 400 V larm equipment 1 free alarm input 8) maporter NE 1 ~ 230 V: bimetal switch in the motor; maporter ND 3 ~ 400 V: no bimetal switch maporter 33
34 uilding Services: Drainage Feature Design Float switch Pneumatic ubbler control bubbler control 1 digital high water alert input (e.g. for float switch) Voltfree contact (changeover contact) for general fault/operation message Piezo buzzer 85 d() Horn 105 d() / alarm combination / alarm o o o o strobe light V D Inputs/outputs Inputs for float switches m analog input Integrated pneumatic pressure sensor up to 3 metres of water up to 10 metres on request ubbler system with compressor up to 2 metres of water Remote acknowledgement V D connection for horn, alarm combination, alarm strobe light Sensors Float switch (NO contact) o Redundant float switch (NO contact) for high o o o water Pressure bell (open system) for pneumatic and o o o bubbler control system Pressure bell (closed system) for pneumatic o system F1 moisture sensor o o o o Tools KS ServiceTool for Windows XP o o o o Key to the symbols Symbol Description o Optional vailable Not available 34 maporter
35
36 Lenntech Tel Fax /10EN
Design details Design. Installation types. Shaft seal. Impeller type. Drive. Bearings
ma-porter ode Description Starting aid 1) Without start capacitor With start capacitor 5 Size 5 DN 6 DN 65 01 Impeller size SE Motor version SE Single-phase motor with float switch NE Single-phase motor
More informationPump Station. Ama-Porter CK Pump Station. Type Series Booklet
Pump Station Ama-Porter CK Pump Station Type Series Booklet Legal information/copyright Type Series Booklet Ama-Porter CK Pump Station All rights reserved. The contents provided herein must neither be
More informationAutomatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet
Automatic Waste Water Pump Station Evamatic-Box N Type Series Booklet Legal information/copyright Type Series Booklet Evamatic-Box N All rights reserved. The contents provided herein must neither be distributed,
More informationWaste Water, Condensate and Heat Transfer Liquid Pump. Type Series Booklet
Waste Water, Condensate and Heat Transfer Liquid Pump MK Type Series Booklet Legal information/copyright Type Series Booklet MK All rights reserved. The contents provided herein must neither be distributed,
More informationWaste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet
Waste Water, Condensate and Heat Transfer Fluid Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied,
More informationGrey Water and Condensate Pump. Rotex. Type Series Booklet
Rotex Type Series Booklet Legal information/copyright Type Series Booklet Rotex Original operating manual All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationAma-Porter S. Cutter device S 50 Hz. Submersible motor pumps. Designation
Type series booklet 2541.51/7--10 Submersible motor pumps Cutter device S 50 Hz Fields of Application Pumping of waste water containing solid matter or domestic sewage such as waste from toilets, washing
More informationSubmersible motor pumps DN Hz
Type series booklet 2563.51/3-10 Amarex NS32 Submersible motor pumps DN 32 50 Hz Applications Amarex N S 32-160 submersible motor pumps are used for pumping waste water in intermittent operation, e.g.
More informationAma-Porter. Submersible motor pumps 50 Hz. Designation
Type series booklet 2539.51/09-EN Ama-Porter Submersible motor pumps 50 Hz ields of Application Pumping of waste water containing solid matter or domestic sewage such as waste from toilets, washing machines,
More informationAma-Drainer-Box Type Series Booklet
Automatic Waste Water Lifting Unit Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationSubmersible Motor Pump. Amarex N. 60 Hz. Type Series Booklet
Amarex N 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet Amarex N All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or
More informationCompacta r. Floodable sewage lifting units. Bearings Maintenance-free greased-for-life deep-groove ball bearings.
Type series booklet 2317.55/4EN r Floodable sewage lifting units EN 12 0501 U3.0 U3.150 U3.450 Applications units are used for the disposal of sewage from toilets, washing and shower facilities as well
More informationSubmersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet
Submersible Borehole Pump UPAchrom 4", UPAchrom 1 CC + DN 1 Type Series Booklet Legal information/copyright Type Series Booklet UPAchrom All rights reserved. The contents provided herein must neither be
More informationFloodable Sewage Lifting Unit. mini-compacta. Type Series Booklet
Floodable Sewage Lifting Unit mini-compacta Type Series Booklet Legal information/copyright Type Series Booklet mini-compacta All rights reserved. The contents provided herein must neither be distributed,
More informationAma Porter. 50 Hz. Submersible motor pumps
Type series booklet 2539.51 10 Ama Porter Submersible motor pumps 50 Hz Fields of Application Pumping of waste water containing solid matter or domestic sewage such as waste from toilets, washing machines,
More informationSewage transport Submersible pumps
Series description Wilo-Rexa FIT Available from January 2012 Construction Submersible sewage pump with cast iron hydraulics and stainless steel motor Type key Example: Wilo Rexa FIT V06DA-110/EAD1-2-T0015-540-A
More informationSubmersible motor pumps DN 50 to Hz
Type Series Booklet 2563.5/6-10 Amarex N Submersible motor pumps DN to 100 Hz Fields of Application Amarex N pumps are used for handling all types of waste water, e.g.: waste water / sewage, waste water
More informationSeries description: Wilo-Drain MTC
H/m Series description: Wilo-Drain MTC Wilo-Drain MTC 50 40 30 20 10 0 Design Submersible sewage pump with external macerator for intermittent and permanent operation, made of grey cast iron for stationary
More informationSubmersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet
Submersible Borehole Pump UPAchrom 4", UPAchrom 1 CC + DN 1 Type Series Booklet Legal information/copyright Type Series Booklet UPAchrom All rights reserved. The contents provided herein must neither be
More informationAma -Porter. Submersible motor pumps 50 Hz. Designation
Type series booklet 2539.51/4--10 Submersible motor pumps 50 Hz ields of Application Pumping of waste water containing solid matter or domestic sewage such as waste from toilets, washing machines, dishwashers,
More informationSeries description: Wilo-Drain STS 40
Series description: Wilo-Drain STS H/m 12 Wilo-Drain STS 1 8 6 2 2 6 8 1 12 1 16 Q/m³/h Design Submersible sewage pump Application Pumping of heavily contaminated fluids for: Domestic and site drainage
More informationSubmersible Mixer. Amamix. 60 Hz. Type Series Booklet
Amamix 60 Hz Type Series Booklet egal information/copyright Type Series Booklet Amamix All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationLenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.
Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Circulator Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents
More informationLenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump
Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Drinking Water Pump Calio-Therm S Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S
More informationJUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS
APPLICATION The centrifugal submersible drainage pumps US 62-251 can be used wherever sewage water with solids up to 10 mm particle size occurs, e.g. in collecting sumps for ground water, or in permanent
More information10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage
Submersible drainage pumps US 6-5 0 mm free passage Application The submersible drainage pumps US 6-5 can be used wherever sewage water with solids up to 0 mm particle size occurs, e.g. in collection sumps
More informationDewatering Submersible sewage pumps
Series description Wilo-Drain TP 80/TP 100 Equipment/function Thermal motor monitoring Leakage detection in the motor ATEX-certified Sheath current cooling Materials Pump housing: PUR Impeller: PUR Shaft:
More informationData sheet. KRTF /24XEG-S IE3 Version no.: 3. Operating data. Design. Driver, accessories
Data sheet Item no.: 100 Page: 1 / 5 Operating data Requested flow rate 178.00 US GPM Requested developed head 14.40 ft Pumped medium Water Clean water Not containing chemical and mechanical substances
More informationBoiler Feed Booster Pump YNK. Type Series Booklet
YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any
More informationHigh-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet
High-efficiency Drinking Water Pump Rio-Eco Therm N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco Therm N All rights reserved. The contents provided herein must neither be
More informationABS submersible sewage pump AFP
BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance
More informationHeat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet
Heat Transfer Fluid / Hot Water Pump HPK-L Type Series Booklet Legal information/copyright Type Series Booklet HPK-L All rights reserved. The contents provided herein must neither be distributed, copied,
More informationwaste water and sewage pumps
waste water and sewage pumps dp pumps technical data INDEX General information 02 Selection charts 04 Pump characteristics 06 Model identification 07 DVV 3 / DVV 4 08 DVV 7 DVV 7 VD 12 DVV 7 K 14 DVV 16
More informationJUNG PUMPEN MULTICUT SEWAGE PUMPS
APPLICATION Centrifugal submersible sewage pumps fitted with the MultiCut cutting system are used as stationary appliances for backpressure protection of detached houses. They are suitable for pumping
More informationEtanorm SYT Type Series Booklet
Thermal Oil / Hot Water Pump Etanorm SYT Type Series Booklet Legal information/copyright Type Series Booklet Etanorm SYT All rights reserved. The contents provided herein must neither be distributed, copied,
More informationJUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS
APPLICATION The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationJUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS
APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In
More informationEtaline MN. In-line Pumps
Type Series Booklet 1146.51/05--EN Etaline In-line Pumps Automation products available: Hyamaster hyatronic Fields of Application F Heating systems F Air-conditioning systems F Cooling circuits F Service
More informationDP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET DP10.65.26.A.2.50B Grundfos pump 96106544 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/dpfam/96106544/dp10-65-26-a-2-50b.html
More informationJUNG PUMPEN compli 100 MC Sewage lifting stations
Application The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationBOAX-B Mat E. Type Series Booklet
Butterfly Valve with Electric Actuator BOAX-B Mat E PS 16 bar: DN 40 to 200 PS 10 bar: DN 250 and 300 Design to EN 593 and ISO 10631 Type Series Booklet Legal information/copyright Type Series Booklet
More informationHOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400
The source for world wide pump technology HOMA Product Range Electric Submersible Sewage Pumps Ranges K, KX Submersible drainage pumps Contractor pumps Drainage pumps for emergency application Deepwell
More informationCONDA-VLC Type Series Booklet
Level Control Valve PN 16 DN 25-300 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationSE M.C.N.51D
GRUNDFOS DATA BOOKLET SE1.110.200.200.4.52M.C.N.51D Grundfos pump 98179813 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/98179813/se1-110-200-200-4-52m-c-n-51d.html
More informationELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Ranges MX, V, K Discharge Size DN 80 - DN 150
ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS Ranges MX, V, K Discharge Size DN 80 - DN 150 T h e s o u r c e f o r h i g h e f f i c i e n c y High Performance in Waste Water Pumping HOMA submersible waste
More informationMultilift M, MD, MDV, and MD1 ranges
Multilift_front.qxd 19-05-2006 13:32 Side 1 GRUNDFOS WASTEWATER Multilift M, MD, MDV, and MD1 ranges 303_616_br_lifting_uk.qxd 22/02/05 8:46 Side 2 Grundfos Lifting Stations Reduced costs and optimised
More informationCOLLECTION STATIONS AND WASTE WATER LIFTING DESIGN SPECIFICATIONS
Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 VACUSYSTEM 2 is an automatic pumping station, pre-assembled and ready to use. The ideal solution when waste water is collected
More informationElectric submersible pumps SEMISOM for sewage water
40 SEMISOM Electric submersible pumps SEMISOM pplication - To convey waste and sewage water from septic tanks; - To drain rain water; - To pump liquids containing solids and filaments; - To pump sewage
More informationGrease Lubrication Pump FK
1-3033-EN 1-0358-US for use in progressive, single-line and dual-line centralized lubrication systems pplication he FK pump unit is a multi-function piston pump whose modular structure makes it very versatile.
More informationSL B. Grundfos pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET SL1.50.65.09.2.50B Grundfos pump 96106566 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1000/96106566/sl1-50-65-09-2-50b.html
More informationTechnical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.
Technical Data DML Submersible Sewage s with Single Channel Impeller AUSTRALIA PTY. LTD. DML_Techdata_SS_V Contents -SPECIFICATIONS FEATURES & APPLICATIONS TYPICAL EXPLODED VIEW SPECIFICATIONS SELECTION
More informationELECTRIC SUBMERSIBLE PUMPS SEMISOM/80
Electric pumps for professional applications to convey sewage water, entirely designed and manufactured in our Italian facility. APPLICATION PERFORMANCE RANGE To convey waste and sewage water from septic
More informationCONDA-VRC Type Series Booklet
Pressure Reducing Valve PN 16/25/40/63 DN 15-150 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied,
More informationDGN. Set-back vortex impeller. electrical submersible pumps. General characteristics
electrical submersible pumps www.ipspumps.be Set-back vortex impeller General characteristics Set-back vortex impeller motor power,, kw poles / / 6 delivery port GAS / vertical DN65 DN50 horizontal free
More informationSEV D. Grundfos Pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET SEV.6.6...1D Grundfos Pump 96779 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sev/96779/sev-6-6---1d.html
More informationabc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.
CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage
More informationPriox. The new range NOCCHI. Lenntech NOCCHI. Tel Fax waste water treatment
NOCCHI Lenntech info@lenntech.com Tel. +31-152-1-9 www.lenntech.com Fax. +31-152-1-289 The new range NOCCHI Priox waste water treatment submersible vortex pumps for waste water Nocchi Priox Submersible
More informationCR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz
GRUNDFOS DATA BOOKLET CR15-1 A-F-A-E-HQQE 11kW 3x4D 5Hz Grundfos Pump 965191 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965191/cr-15-1-a-f-a-e-hqqe.html
More informationDWK.E D.R
GRUNDFOS DATA BOOKLET DWK.E.1.15.55.5.1D.R Grundfos Pump 96922755 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/dwk/96922755/dwk-e-1-15-55-5-1d-r.html
More informationElectric submersible pumps SEMISOM for sewage water
pplication - To convey waste and sewage water from septic tanks; - To drain rain water; - To pump liquids containing solids and filaments; - To pump sewage water even through pipes with reduced diameter
More informationManual Actuator. MA Manual Gearbox Force Transmission via Planetary Gear Torque Range up to 250 Nm. Type Series Booklet
Manual Actuator MA MA Manual Gearbox Force Transmission via Planetary Gear Torque Range up to 250 Nm Type Series Booklet Legal information/copyright Type Series Booklet MA All rights reserved. The contents
More informationCRE15-01 A-F-A-E-HQQE 1x HZ
GRUNDFOS DATA BOOKLET CRE15-1 A-F-A-E-HQQE 1x22-24 5 HZ Grundfos Pump 96512684 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre15/96512684/cre-15-1-a-f-a-e-hqqe.html
More informationblue series bluepro series
5Hz water solutions blue series bluepro series DG blue DR blue DG bluepro DR bluepro GR bluepro AP bluepro D a t a b o o k l e t EN water solutions blue series bluepro series DG blue DR blue DG bluepro
More informationCR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ
GRUNDFOS DATA BOOKLET CR5-26 A-FGJ-A-E-HQQE 3x4D 5HZ Grundfos Pump 96513391 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96513391/cr-5-26-a-fgj-a-e-hqqe.html
More informationSDL i MACERATING SUBMERSIBLE PUMPS
OPERATING LIMITS Flow up to: 6 m 3 /h Head up to: 36 m Max. particle size: 6 mm DN of discharge port: Protection index: 68 SDL i MACERATING SUBMERSIBLE PUMPS Lifting of waste water Commercial pole - 5
More informationData sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)
Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 14.5 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H
More informationEBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model
Contents Model A0553 C1125 V0494 A0713 C1285 V0554 A0843 C1455 V0754 A03 C15 V0854 C1915 V0974 C2185 V1154 C2905 Section Page Specifications 3-3 Model Designation 3-6 Impeller Data 3-8 Material Specifications
More informationVERTICAL IN-LINE PUMP
VERTICAL IN-LINE PUMP TECHNICAL FEATURES ELINE: Vertical centrifugal pumps, single impeller, volute casing, non-self priming pump, in-line executive, with mechanical seal. Hydraulically designed in line
More informationGRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz
GRUNDFOS DATA BOOKLET AP, KP Wastwater pumps 5 z Contents General data Performance range Page 3 Applications Page 5 Examples of application Page 5 Pump overview Page 6 Type key for AP pumps Page 6 Type
More informationInstruction Manual. Sewage lifting station compli 300
Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803
More informationTRITUS. Submersible pumps with grinder
TRITUS Submersible pumps with grinder Filthy water Domestic use Civil use PERFORMANCE RANGE Flow rate up to 26 l/min (5.6 m³/h) Head up to 3 m APPLICATION LIMITS m maximum immersion depth (with a sufficiently
More informationGRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions
GRUNDFOS WASTEWATER S range 1.65 5.0 kw 50 and 60 Hz versions Grundfos Powerful pumps for handling unscreened raw sewage Grundfos offers a complete range of highly dependable, powerful sewage pumps, designed
More informationELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Rangess AK, KXAKX Discharge Size DN 200 DN
ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS Rangess AK, KXAKX Discharge Size DN 200 DN 500 T h e s o u r c e f o r h i g h e f f i c i e n c y High Performance in Waste Water Pumping HOMA submersible waste
More informationDewatering pumps for raw water pumping. / / grundfos DW RANGE
grundfos DW RANGE Dewatering pump 0.7 - kw Dewatering pumps for raw water pumping efficient state-of-art dewatering pumps Unique user benefits The Grundfos DW pumps form part of a complete range of wastewater
More informationCR10-10 A-A-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR1-1 A-A-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651232 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651232/cr-1-1-a-a-a-e-hqqe.html
More information4 Specification Magneta Smedegaard twin pumps
4 Specification Magneta Smedegaard twin pumps 4.1 Variable Speed Circulator Pumps Designation: Example Magneta Smedegaard 30-60D Key to the designation Main applications Heating, ventilation, air-conditioning,
More informationStrainers BOA -S. PN 6/16/25 DN Flanged. Type Series Booklet
BOA -S PN 6/16/25 DN 15-300 Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA -S KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither
More informationCR A-F-A-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CR64-7-1 A-F-A-V-HQQV 3x4/69 5 HZ Grundfos Pump 96123566 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123566/cr-64-7-1-a-f-a-v-hqqv.html
More informationCR15-02 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR15-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651893 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651893/cr-15-2-a-f-a-e-hqqe.html
More informationCirculator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control
Type series booklet 1115.52/2-10 Riotec r /Riotec r Z Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control Riotec Riotec Z Energy efficiency class
More informationSwing Check Valve AKR/AKRS. PN DN 80/80 to 300/250. Type Series Booklet
Swing Check Valve AKR/AKRS PN 63-160 DN 80/80 to 300/250 Type Series Booklet Legal information/copyright Type Series Booklet AKR/AKRS All rights reserved. The contents provided herein must neither be distributed,
More informationSeries description: Wilo-Drain TM/TMW/TMR 32
Series description: Wilo-Drain TM/TMW/TMR 32 H[m] 10 Wilo-Drain TM /TMR /TMW 32 8 6 TM 32/7 4 TM 32/8 TMW 32/8 2 TMW 32/11 TMR 32/8 TMR 32/11 0 0 2 4 6 8 10 12 Q[m³/h] Design Basement drainage pump, water-cooled
More informationDML - DMLV. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron 3,7 5,5 7, LM 80 OUTPUT DIAMETER 80
Cast iron submersible electric pumps for sewage. APPLICATIONS Evacuation of civil and industrial waste waters Treating liquid manure Draining sublayer zones Generally moving foul waste liquids also containing
More informationCRE10-02 A-A-A-E-HQQE 1x HZ
GRUNDFOS DATA BOOKLET CRE1-2 A-A-A-E-HQQE 1x2-24 5 HZ Grundfos Pump 9651251 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre1/9651251/cre-1-2-a-a-a-e-hqqe.html
More informationCR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CR5-6 A-FGJ-A-E-HQQE 3x23/4 5HZ Grundfos Pump 9651741 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651741/cr-5-6-a-fgj-a-e-hqqe.html
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32-1-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 9612224 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612224/cr-32-1-2-a-f-a-e-hqqe.html
More informationCR45-5 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-5 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 9612285 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612285/cr-45-5-a-f-a-e-hqqe.html
More informationThermal Oil / Hot Water Pump. Etanorm SYT. General Arrangement Drawings
Thermal Oil / Hot Water Pump Etanorm SYT General Arrangement Drawings Legal information/copyright General Arrangement Drawings Etanorm SYT All rights reserved. The contents provided herein must neither
More informationCR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CR3-19 A-FGJ-A-E-HQQE 3x23/4 5HZ Grundfos Pump 96516663 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96516663/cr-3-19-a-fgj-a-e-hqqe.html
More informationCRE5-16 A-A-A-E-HQQE 3x400 50HZ
GRUNDFOS DATA BOOKLET CRE5-16 A-A-A-E-HQQE 3x4 5HZ Grundfos Pump 96518432 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre5/96518432/cre-5-16-a-a-a-e-hqqe.html
More informationMag-drive Pump. Magnochem-Bloc. Type Series Booklet
Mag-drive Pump Magnochem-Bloc Type Series Booklet Legal information/copyright Type Series Booklet Magnochem-Bloc All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR64-3-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96123531 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123531/cr-64-3-2-a-f-a-e-hqqe.html
More informationSTAAL 40 AKK/AKKS. Type Series Booklet
Swing Check Valve STAAL 40 AKK/AKKS PN 10-40 DN 80-400 Bolted cover Flanged/Butt Weld Ends Type Series Booklet Legal information/copyright Type Series Booklet STAAL 40 AKK/AKKS KSB Aktiengesellschaft Pegnitz
More informationCR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CR3-2 A-FGJ-A-E-HQQE 3x23/4 5HZ Grundfos Pump 96516649 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96516649/cr-3-2-a-fgj-a-e-hqqe.html
More informationSubmersible Mixer. Amaprop. 50 Hz For Biogas Plants. Type Series Booklet
Amaprop 50 Hz For Biogas Plants Type Series Booklet Legal information/copyright Type Series Booklet Amaprop All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationCR A-F-A-V-HBQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CR12-6-1 A-F-A-V-HBQV 3x4/69 5 HZ Grundfos Pump 95922172 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922172/cr-12-6-1-a-f-a-v-hbqv.html
More informationSelf-priming Pump. Etaprime B. Type Series Booklet
Self-priming Pump Etaprime B Type Series Booklet Legal information/copyright Type Series Booklet Etaprime B All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationCR45-10 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122815 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122815/cr-45-1-a-f-a-e-hqqe.html
More informationLIFTSON M-LIX L. LIFT-PUMP MODULES Domestic waste water 50 Hz Complies with standard EN RANGE OF APPLICATION APPLICATIONS ADVANTAGES
RANGE OF APPLICATION Flows up to: 40 m 3 /h Manometric head up to: 22 m Maximum water temperature: + 3 à 40 C Particle size: 45 mm Inlet pipe: DN 40/50/100/150 Outlet: DN 80 Vent: DN 70 LIFTSON M-LIX L
More informationCRN A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN64-7-2 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 96123813 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn64/96123813/crn-64-7-2-a-f-g-v-hqqv.html