3/ ABB cable accessories for PILC kv General accessories and Tools

Size: px
Start display at page:

Download "3/ ABB cable accessories for PILC kv General accessories and Tools"

Transcription

1 / ABB cable accessories for PILC kv General accessories and Tools

2 Table of content General accessories and tools, kv General accessories and tools Other accessories, tapes / Other accessories /4 Tools /6 General accessories and Tools ABB cable accessories for PILC kv 2015 /2

3 Other accessories Tapes IA 2-28 Insulating vulcanizing tape. IA 29 Insulating vulcanizing tape. IA 242 Silicon rubber tape. IA 24 Silicon rubber tape. IA 252 Semiconducting tape. IA 262 Filling tape. IA Protective tape. RULLE Two-layer insulating tape made of EPDM and butyl rubber. IA 2421 Electrical tape. Designation Length Width Thickness Weight m mm mm kg/item IA IA IA IA IA IA IA IA IA IA IA IA RULLE RULLE / 2015 ABB cable accessories for PILC kv General accessories and Tools

4 Other accessories IK 1105, 1106, 1107, 1108, 1109 Abrasive cloth. IK 1405, IK 1406 Lashing wire (tin-coated copper wire). IK 1401, IK 1407 Lashing wire (tin-coated copper wire). IK 2221 Silicone grease, 25 g. IK 22 Grease, type AP paste, 10 g. IK 1502 Lashing wire (galvanized steel wire). Designation Length Diameter Coarseness Weight m mm kg/item IK IK IK IK IK IK IK IK IK IK IK IK General accessories and Tools ABB cable accessories for PILC kv 2015 /4

5 Other accessories IA 1701 Earthing braid, sold by the metre, 10 mm². IA 1706 Copper net for e.g. SMXB, sold by the metre, approx. 10 mm². IK 220 Washing cloth, alcohol-soaked paper cloths 200 x 00 mm. SKALUS Peeling string for XLPE-insulation. MBR 250 Stainless marking tape, 100 units/kit. Designation Length Width Thickness Weight m mm mm IA kg/m IA kg/m IK kg/unit SKALUS kg/unit MBR kg/kit / ABB cable accessories for PILC kv General accessories and Tools

6 Accessories Tools (all dimensions in mm) R Torque wrench for bolt connectors, bolt cable lugs, overhead line clamps, etc. Supplied with 7 mm socket head, extension and 8 mm internal hexagon head. Torque range 6-50 Nm. Intercable No. RKS Cable shears for cutting cable Ø max 54 mm RKM 1055 Splitting tool for longitudinal splitting off XLPE-insulation with Ø mm. RKM 670 Cable knife, 0 mm blade. 0 RKM 672 Sheath removing knife with two handles for plastic sheated cable. RKM 145 and RKM 2550 Brace for use in the assembly of the connectors and cable lugs with a torque or shear-off screw. Provides a secure and stable mounting. Adjustable between min and max diameter of the connector or cable lug. Available in two sizes according to the table. Meets the insulation requirements of EN/IEC RKM SB Cordless impact wrench set to fit connectors and cable lugs with shear-off bolts. Meets the insulation requirements of EN/IEC The kit includes: Impact wrench Battery: 18 V/.0Ah - 2 st Battery charger Allen nut: SW5, SW6, SW8 Designation Description 70 R Torque wrench RKS Cable shears RKM 1055 Splitting tool RKM 1055 K Spare blade for RKM 1055 RKM 672 Sheath removing knife RKM 145 Brace for bolted connector for outer diameter of 14 5 mm RKM 2550 Brace for bolted connector for outer diameter of mm RKM 670 Cable knife RKM SB Cordless impact wrench set General accessories and Tools ABB cable accessories for PILC kv 2015 /6

7 Accessories Tools (all dimensions in mm) Intercable No. AV 6220 Sheath removing tool for PE-sheathed cable Ø > 20 mm. Model 1700 Series Peeling tool for strippable outer conductive layer on XLPE-insulated cable Ø 1-51 mm Intercable No. FBS Stripping tool for the vulcanized, outer conducting layer of XLPE-insulated cable Ø mm. The tool is supplied in a rigid case with a tube of silicone grease. GB-M20 Cutting tool for cable sheath and XLPE-insulation: Diameter: Ø mm Cutting depth: 8 mm GB-M20 S8 Spare peeling blade to GB-M20. Delivered 1 per kit. Designation AV 6220 Model 1700 Series FBS GB-M20 GB-M20 S8 Description Sheath removing tool Peeling tool Stripping tool XLPE stripping tool Spare blade for GB-M20 S8 / ABB cable accessories for PILC kv General accessories and Tools

8 General accessories and Tools ABB cable accessories for PILC kv 2015 /8

Premolded cable joint with cold shrink outer jacket SOJ kv

Premolded cable joint with cold shrink outer jacket SOJ kv Premolded cable joint with cold shrink outer jacket SOJ 12 24 kv Premolded cable joint for XLPE- and EPR-insulated 1- or -core cables with l or u conductor, 12 24 kv. SOJ SS Standards ENELE, H 629.1 S1

More information

Catalog May Cable Accessories kv

Catalog May Cable Accessories kv Catalog May 015 Cable Accessories 5 40 kv Table of content Cable Accessories 1 Cable Accessories for XLPE-insulated cables 5 40 kv List of content Alphabetical order 3 List of content by Category 4 Data

More information

Catalog May Cable Accessories kv EPR- and XLPE-insulated cables

Catalog May Cable Accessories kv EPR- and XLPE-insulated cables Catalog May 015 Cable Accessories 7. 4 kv EPR- and XLPE-insulated cables Table of content Cable Accessories 1 Cable accessories, 7. 4 kv General accessories and tools 3 Universal clamps 4 List of content

More information

Installation instruction PEM1150ENG

Installation instruction PEM1150ENG Installation instruction PEM1150ENG 2008-08 USHJ630 SCREENED SEPARABLE BACK CONNECTOR 630 A FOR 1 CORE PLASTIC CABLES 12-24 kv ENGLISH 2/8 USHJ630 PEM1150ENG 2008-08 GENERAL INFORMAT ION - Check that the

More information

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K) IS94012-ENG - AFN 20-45 5 February 2013 - Revision 6 - Supersedes edition of 28 January 2013 Page 1 of 7 CAUTION: Read instructions thoroughly and completely prior to beginning installation. Installation

More information

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor

More information

(K),(M)430TB/G Up to 36 kv

(K),(M)430TB/G Up to 36 kv IS90722-ENG - 430TB/G-45 25 June 2009 - Revision 8A - Supersedes edition of 25 November 2008 Page 1 of 10 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation

More information

Catalog August 2013 Kabeldon cable accessories kv Product catalog 2013

Catalog August 2013 Kabeldon cable accessories kv Product catalog 2013 Catalog August 2013 Kabeldon cable accessories 1 420 kv Product catalog 2013 Table of contents Introduction 1 Cable accessories 1 kv 2 Cable accessories for XLPE-insulated cables 7.2 42 kv 3 Cable accessories

More information

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv EUROMOD NV 0/00 www.think-media.be Accessories for medium voltage power cables Terminations Cold-shrinkable Silicone kv - kv - 6 kv Catalogue 0/00 TERMINATIONS TABE OF CONTENTS COD-SHRINKABE SIICONE TERMINATIONS

More information

(K),(M),(P)489TB/G Up to 42 kv

(K),(M),(P)489TB/G Up to 42 kv IS91374-ENG - 489TB/G-45/S 22 October 2012 - Revision 1 - Supersedes edition of 4 May 2012 Page 1 of 9 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation

More information

power cable accessories

power cable accessories power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten

More information

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools Medium voltage - Cable accessories up to 36 kv Tapes Connection technique Tools TABLE OF CONTENTS General information... 6 7 CAST RESIN-TECHNIQUE...8 11 Straight-through joints for polymeric-insulated

More information

High Voltage Joints and Terminations up to 72,5 kv 145 kv

High Voltage Joints and Terminations up to 72,5 kv 145 kv High Voltage Joints and Terminations up to 72,5 kv 145 kv 3M Cold Shrink Termination Kits QT-III and Joint Kits are designed to provide high reliability and save you time and money. They install quickly

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

ELB ELB

ELB ELB ELB-35-600 ELB-35-610 600A T-Body Elbow Connectors for Copper Tape (CT), Jacketed Concentric Neutral (JCN), and Concentric Neutral (CN) cables up to 35kV class Safety Instructions When installing electrical

More information

USE-USU. Steel independent chucks. Steel independent chucks USE-USU

USE-USU. Steel independent chucks. Steel independent chucks USE-USU USE-USU The jaws can be centered approximately by adjusting them to the concentric grooves, accurate centering requires the use of a dial indicator. Independent 4-jaw chuck Technical features: - jaws individually

More information

a Nexans company Catalogue 2008

a Nexans company Catalogue 2008 a Nexans company Catalogue 2008 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium

More information

High Voltage Accessories up to 72.5 kv

High Voltage Accessories up to 72.5 kv High Voltage Accessories up to 72.5 kv Technical instructions and application information The data given were determined diligently, but do not release our customers of the duty to carry out tests themselves

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,417 35 41.0 2,865 50 44.0 3,391 70 48.0 4,272 95 51.5 5,266 120 55.5 6,232

More information

INSTALLATION INSTRUCTION PEM1121ENG ENGLISH

INSTALLATION INSTRUCTION PEM1121ENG ENGLISH INSTALLATION INSTRUCTION PEM1121ENG 2016-06 ENGLISH SJK JOINT KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv SJKR JOINT KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv 2/8 PEM1121ENG 2016-06 GENERAL INFORMAT ION

More information

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Class I Indoor Termination Voltage Designation: 12/20(24) kv Kit Contents: 1 HeatShrinkBreakoutBootAssembly 3 HeatShrinkBindingSleeves

More information

INSTALLATION INSTRUCTION PEM1093ENG ENGLISH

INSTALLATION INSTRUCTION PEM1093ENG ENGLISH INSTALLATION INSTRUCTION PEM1093ENG 2017-04 ENGLISH HEAT SHRINK TERMINATIONS FOR SINGLE CORE CABLES INDOOR TERMINATIONS HIT1.12, HIT1.24 AND HIT1.36 OUTDOOR TERMINATIONS HOT1.12, HOT1.24 AND HOT1.36 2/12

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION HEAT SHRINKABLE TERMINATION FOR 11kV, 3 CORE, XLPE/PVC COPPER WIRE SCREEN UNARMOURED CABLE. INDOOR & OUTDOOR. Cable Dielectric INDOOR INSTRUCTION No PJT001-14A XLPE/EPR OUTDOOR Tested to IEC60502-4 (TDT

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC For Tape Shield or Longitudinally Corrugated (LC) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

Insulation displacement terminals. OEC Product Catalogue

Insulation displacement terminals. OEC Product Catalogue Insulation displacement Terminals for Low Voltage cables Series CNT/PRF-1 UNIPOLAR INSULATION DISPLACEMENT BRANCH TERMINALS for SELF-SUPPORTING LOW VOLTAGE CABLES TYPE DM 6050/1 Article code: N0CE0031

More information

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254. 3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200

More information

Cold Shrink QS T Trifurcating Transition Splice Kit

Cold Shrink QS T Trifurcating Transition Splice Kit Cold Shrink QS2012-13-3T Trifurcating Transition Splice Kit Instructions IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice Cable Size Range Requirements PILC 500 kcmil Conductor Size (240 mm 2

More information

Cellplux Plug-in Technology

Cellplux Plug-in Technology simple, secure, quick to assemble solution for entire cross-section range only standard tool required unlimited shelf life type tested to CENELEC HD 629.1 D827 SAP-No. 206884 0313 Perfect connection Profit

More information

Rotary inlets for pressurised oil, compressed air

Rotary inlets for pressurised oil, compressed air Rotary inlets for pressurised oil, compressed air Product data sheets Rotary inlets for pressure oil, single channel 0086-010-size-160 9.03.00 Rotary inlets for pressure oil, two- channel 0088-226/326-size-010040

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

N2XSERY 3 x (25-300) mm² 3.6/6 kv

N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 41.0 3,102 35 43.5 3,587 50 48.0 4,576 70 52.0 5,579 95 55.5 6,642 120 59.5 7,711

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Termination 3M Cold Shrink QT-III Silicone Rubber Termination For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable 7673-S-8(S)-TOW/WOT Instructions IEEE Std. No. 48 Class 1 Termination 69 kv Class, 350

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

INSTALLATION INSTRUCTION PEM1367ENG ENGLISH

INSTALLATION INSTRUCTION PEM1367ENG ENGLISH INSTALLATION INSTRUCTION PEM1367ENG 2012-06 ENGLISH COLD SHRINK JOINT CJE11.42 FOR SINGLE CORE CABLES WITH Cu WIRE SHIELD Uo/U = 20.8/36 kv, Um = 42 kv 2/10 CJE11.42 PEM1367ENG 2012-06 GENERAL INFORMATION

More information

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) 3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) for Tape Over Wire and Wire Over Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325

More information

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions Raychem CSJA 1521 Cold-Shrinkable Splice for single core polymeric insulated (XLPE-EPR) cables up to 15kV for tape, wire, Unishield, LC shield, JCN, and flat strap neutral cable UniShield is a trademark

More information

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW) 3M Cold Shrink Skirted Termination Kit QT-III 7672-S-8-TS (RW) for Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325 kv BIL CAUTION Working around energized systems

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

High Voltage and Extra High Voltage Cables

High Voltage and Extra High Voltage Cables High Voltage and Extra High Voltage Cables GUIDE TO THE SELECTION OF EHV AND HV CABLES EHV and HV cables are specially designed on the basis of the project data. To determine appropriate design of a high

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

Silicone Push-on Accessories

Silicone Push-on Accessories Silicone Push-on Accessories RXS Kabelgarnituren GmbH & Co. KG 67 Push-on Straight Joint AMS 10, AMS 20 For 1-Conductor Polymer-Insulated Power Cables ) = 6 / 10 (12) kv; 12 / 20 (24) kv Design The AMS

More information

Installation Instructions

Installation Instructions 517 Lyons Ave, Irvington, NJ 07111 Phone: 973-371-1771 Fax: 973-371-4304 Installation Instructions Deadbreak Elbow Applicable Current Ratings 600A (Aluminum) 900A (Copper) Applicable Catalog Prefix 35kV

More information

PRODUCT CATALOGUE. Distributor: BODDINGTONS ELECTRICAL PRODUCT CATALOGUE EDITION 3

PRODUCT CATALOGUE. Distributor: BODDINGTONS ELECTRICAL PRODUCT CATALOGUE EDITION 3 BODDINGTONS ELECTRICAL PRODUCT CATALOGUE EDITION 3 PRODUCT CATALOGUE w w w. b o d d i n g t o n s - e l e c t r i c a l. c o m Distributor: Prospect House, Queenborough Lane Great Notley, Braintree, CM77

More information

LOCKN LOAD FIRST TIME INSTALLATION

LOCKN LOAD FIRST TIME INSTALLATION LOCKN LOAD TM TRACK MOUNTING KIT FORD RANGER PX / MAZDA BT-50 DUAL CAB 2011 + 2 BAR TRACK HEAVY DUTY ROOF RACK SYSTEM MAX VEHICLE ROOF LOAD RATING: 100KG TOTAL LOAD EQUALS WEIGHT OF ROOF RACKS + ACCESSORIES

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS MEDIUM VOLTAGE MV TERMINATIONS INDOOR SINGLE CORE TERMINATION - ELTI-1C APPLICATION Utilisation indoor. in boxes and compact switchgears. in terminal boxes located outdoor and subject to condensation.

More information

Quintas & Quintas Group

Quintas & Quintas Group Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors

More information

Medium voltage cables

Medium voltage cables Medium voltage cables Leading producer of cables and cable systems 2 The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years. A stable

More information

Completing the picture

Completing the picture HIGH VoltaGe cable accessories for 72 kv up to 170 kv Completing the picture based on experience is the future nkt cables GmbH nkt was established in 1891 as cable manufacturer. in 1999 nkt a/s denmark

More information

CONNECTORS AND FITTINGS

CONNECTORS AND FITTINGS Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.

More information

Global data. Electrical parameters

Global data. Electrical parameters ()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

Steel / Cast iron body Independent chucks

Steel / Cast iron body Independent chucks Independent chucks Steel / Cast iron body Independent chucks Independent 4-jaw chucks - Jaws individually adjustable through threaded adjusting spindle. RÖHM-Independent chucks in steel or cast iron design

More information

BWS/MSY-40 Cable stripping machine Operational Manual Bluedog Cable Strippers

BWS/MSY-40 Cable stripping machine Operational Manual Bluedog Cable Strippers BWS/MSY-40 Cable stripping machine Operational Manual Bluedog Cable Strippers www.copper-wire-stripper.com Content Part 1: Safety part 2 Part2: Specification and installation 3-8 Part 3: Operation 8 Part

More information

QT-III Cold Shrink Silicone Rubber

QT-III Cold Shrink Silicone Rubber QT-III Cold Shrink Silicone Rubber 7600-T-3RJS Series 3/C Cabinet Termination Instructions Kit Contents: 3ÑSilicone Rubber Phase Re-jacketing Sleeve Assembly 3ÑCold Shrink Silicone Rubber Termination Assembly

More information

Medium Voltage. Joints & Terminations

Medium Voltage. Joints & Terminations 57 - Cold Shrink Joints Supporting Core Radially shrinkable elastomeric splice Semi-conductive layer High permitivity insulation layer 6.6/11/(12) kv 3M QS1000 is a one-piece cold shrink joint body manufactured

More information

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series 3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Around the cable. Stripping.... convincing solutions

Around the cable. Stripping.... convincing solutions Around the cable Stripping... convincing solutions INFO Cable strippers How to use: For removing the exterior protective sleeve Junctions and distribution boxes For lengthwise and circular cuts Round PVC

More information

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1 Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation...

More information

BEST PRACTICE for the installation of medium voltage cable accessories

BEST PRACTICE for the installation of medium voltage cable accessories BEST PRACTICE for the installation of medium voltage cable accessories CONTENTS 1. INTRODUCTION...3 2. SCOPE...3 3. CABLES...4 3.1 Paper-insulated cables...4 3.2 Polymeric insulated (extruded) cables...5

More information

PSI Anti-Corrosion Tape

PSI Anti-Corrosion Tape General information Technical specifications Requirement evaluation Application instructions Certificates PSI Anti-Corrosion Tape 8 Pipeline Accessories 85 The Systems PSI anti-corrosion tapes have been

More information

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories

More information

MG 300. Spare parts list. Multi grapple Atlas Copco Construction Tools GmbH No

MG 300. Spare parts list. Multi grapple Atlas Copco Construction Tools GmbH No MG 300 Spare parts list Multi grapple 0 Atlas Copco Construction Tools GmbH No. 3390 7354 0 0046 MG 300 Contents Contents General information................................................................

More information

High Voltage Cable Accessories. Tool catalog

High Voltage Cable Accessories. Tool catalog High Voltage Cable Accessories Tool catalog Table of Contents page 1 Cable and screen preparation Cable bending device Cable band saw Cable sheath cutter Cable sheath dismantling fork Cutting and peeling

More information

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable ()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static

More information

DPX - DPAX butterfly valve technical description

DPX - DPAX butterfly valve technical description DPX - DPAX butterfly valve technical description DEFINOX butterfly valves have been made for several years using a choice of materials and machining conditions that guarantee top quality strength and surface

More information

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV * PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE PROCEEDING * INDOOR OUTDOOR Download free QR code scanning software

More information

DEFOGGER SYSTEM PARTS LOCATION

DEFOGGER SYSTEM PARTS LOCATION BE61 PARTS LOCATION TROUBLESHOOTING The table below will be useful for you in troubleshooting these electrical problems. The most likely causes of the malfunction are shown in the order of their probability.

More information

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E BILLET GRILLS IMPORTANT: PLEASE KEEP THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE! 2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete 5122-1900-11E TOOLS REQUIRED Automotive

More information

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS ) Screened Separable Connectors MN650023EN Effective October 2016 Supersedes March 2012 (IS550-60-1) COOPER POWER SERIES DTS1242 Deadbreak Bolted Tee Connector: Interface C for Single Core Cable with Copper

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN For Jacketed Concentric Neutral (JCN) Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350 kv BIL IEC 60840 72,5

More information

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH Nexans WINDLINK connection system Nexans Power Accessies Germany GmbH Technical instructions and application infmation Reprinting, even partial, only with special allowance. The data given were determined

More information

N C T (S) F. Insulation Rubber (EPR)

N C T (S) F. Insulation Rubber (EPR) Type Designation Cable H T P N C T (S) F Cable Type HT : High Tension Cable FC : Festoon Cable SC : Spreader Cable PNCTR : High Cable : NonShield (S) : Shield Cap Tire Rubber (CR) Rubber (EPR) F R : Flat

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS ) Screened Separable Connectors MN650024EN Effective October 2016 Supersedes March 2012 (IS550-61-1) COOPER POWER SERIES DTB1242 Deadbreak Bolted Companion Tee Connector: Interface C for Single Core Cable

More information

INSTALLATION INSTRUCTIONS Accessory Application Publications No. All 40290 BODY SIDE 2009 RIDGELINE Issue Date AUG 2008 PARTS LIST INSTALLATION NOTE: Be careful not to damage the body paint finish. Left

More information

ED 42. ENGINE HOOD / DOOR FRONT DOOR (w/o Power Window)

ED 42. ENGINE HOOD / DOOR FRONT DOOR (w/o Power Window) 42 ENGINE HOOD / DOOR FRONT DOOR (w/o Power Window) (g) (h) Horizontally and vertically adjust the door by loosening the door side hinge bolts. Tighten the door side hinge bolts after the adjustment. Torque:

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

Connecting globally. TFCrane

Connecting globally. TFCrane Connecting globally 1 Table of Contents TELE-FONIK Kable S.. 4 PPLICTION 6 dditional PramETErs 7 REELING CBLE - 0,6/1kV NSHTÖU -J/O 8 (N)SHTÖU -J + FO 15 2 3 REELING CBLE - 3,6/6kV, 6/10kV, 8,7/15kV, 12/20kV

More information

3M Cold Shrink Splice Kits, QS T Series

3M Cold Shrink Splice Kits, QS T Series 3M Cold Shrink Splice Kits, QS-2000-3T Series For 15 kv Trifurcating Transition Splice Kits Data Sheet October 2011 Description 3M Cold Shrink Splice Kits, QS-2000-3T Series for 15 kv Trifurcating Transition

More information

STANDARD FEATURES: Closed 9-1/4" Work Stations From Floor 42" Height w/o Die Block Hydraulics: Optional Lengths Available Weight (NET) lbs 2600

STANDARD FEATURES: Closed 9-1/4 Work Stations From Floor 42 Height w/o Die Block Hydraulics: Optional Lengths Available Weight (NET) lbs 2600 IRONWORKERS The Piranha Model P-50 features Automatic Urethane Hold Downs on the Punch Stripper and Bar, Plate and Angle Shear. This assures precise cuts and longer punch and blade life. Complete Punching

More information

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

a Nexans company Medium voltage symmetrical separable connectors - Interface C - a Nexans company Medium voltage symmetrical separable connectors - Interface C - Catalogue 2011 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised

More information

Medium Voltage Catalogue 2013

Medium Voltage Catalogue 2013 Medium Voltage Catalogue 2013 D813 SAP.Nr. 198693 1112 Medium Voltage 2013 Data, values and illustrations given in this documentation are correct and reliable according to the current state of our knowledge.

More information

PARAMOUNT COMMUNICATIONS LTD.

PARAMOUNT COMMUNICATIONS LTD. LT Power Cables - Aluminium conductor PARAMOUNT BRAND Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor,xlpe Insulated,cores laid up, PVC innersheathed,unarmoured/armoured

More information

General characteristics and technical data Series MCS

General characteristics and technical data Series MCS MOD M MC MCS VP 100 S Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and

More information

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999 STOCKPORT, ENGLAND, TEL: 0161-430 8333 POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS PLEASE READ THE INSTRUCTIONS BEFORE PROCEEDING Recommended Tools ANNEX B Ref TK/AHT Issue C Date 16 August 1999 Heavy

More information

BRACKETS, MOUNTS & HARDWARE

BRACKETS, MOUNTS & HARDWARE HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information