Multiplex Overhead Aluminum Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006
|
|
- Trevor Parsons
- 5 years ago
- Views:
Transcription
1 Multiplex Overhead Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006 Base Price Per MFT Approx. Net Weight Power Neutral Lbs. Per 1000 Feet Package Conductor Pounds Conductor Messenger Type/Size Footage CODE WORD Size -Stranding Type-Size Total (1) Total LDPE XLPE AWG/KCMIL Stranding LDPE XLPE LDPE XLPE Duplex SETTER $ $ ACSR 6-6/ NRC , Coil 1, COLLIE $ $ AAC NRC , Coil 1, CHIHUAHUA $ $ NRC , Coil 1, SHEPHERD * $ $ ACSR 6-6/ NRC * 3, Coil * TERRIER* $ $ ACSR 4-6/ NRC * 2, Coil * VIZSLA $ $ NRC , Coil 1, SPANIEL $ $ AAC NRC , Coil 1, Coil 1, WHIPPET $ $ NRC , Coil 1, CHOW $ $ ACSR 2-6/ NRC , Triplex Coil PATELLA $ $ AAC NRC , Coil 1, HIPPA $ $ NRC , Coil 1, VOLUTA * $ $ ACSR 6-6/ NRC * 2, Coil * OYSTER $ $ AAC NRC , Coil OHSDC-1 1 of 3
2 Base Price Per MFT Approx. Net Weight Power Neutral Lbs. Per 1000 Feet Package Conductor Pounds Conductor Messenger Type/Size Footage CODE WORD Size -Stranding Type-Size Total (1) Total LDPE XLPE AWG/KCMIL Stranding LDPE XLPE LDPE XLPE WHELK $ $ ACSR 4-6/ NRC , Coil PERIWINKLE * $ $ ACSR 4-6/ NRC * 1, NRC * 1, Coil * SCALLOP $ $ ACSR 6-6/ NRC , Coil BARNACLES * $ $ NRC * 1, Coil STROMBUS $ $ ACSR 6-6/ NRC , Coil ARTEMIA $ $ NRC , Coil 1, CRAB $ $ NRC , Coil 1, CLAM $1, $1, AAC NRC , Coil CONCH * $1, $1, ACSR 2-6/ NRC * 1, Coil * COCKLE * $1, $1, ACSR 4-6/ NRC * 1, Coil * SHRIMP * $1, $1, NRC * 1, Coil SOLASTER * $1, $1, NRC , Coil MUREX $1, $1, /0-7 AAC 1/ NRC , Coil NERITINA * $1, $1, /0-7 ACSR 1/0-6/ NRC * 1, Coil * JANTHINA * $1, $1, /0-7 ACSR 2-6/ NRC * 1, Coil * GAMMARUS * $1, $1, / / NRC * 1, Coil SANDCRAB $1, $1, / NRC , Coil PURPURA $1, $1, /0-19 AAC 1/ NRC , Coil CENIA $1, $1, /0-19 ACSR 1/0-6/ NRC , Coil OHSDC-1 2 of 3
3 Base Price Per MFT Approx. Net Weight Power Neutral Lbs. Per 1000 Feet Package Conductor Pounds Conductor Messenger Type/Size Footage CODE WORD Size -Stranding Type-Size Total (1) Total LDPE XLPE AWG/KCMIL Stranding LDPE XLPE LDPE XLPE RANELLA $1, $1, /0-19 ACSR 2-6/ NRC , Coil LEDA $1, $1, / / NRC , Coil ECHINUS $1, $1, / NRC , * Stock Products - XLPE Only Coil OHSDC-1 3 of 3
4 1.04 Multiplex Overhead Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006 CODE WORD Triplex (cont.) Approx. Net Weight Base Price Power Neutral Lbs. Per 1000 Feet Package Conductor Pounds Per MFT Conductor Messenger Type/Size Footage Size -Stranding Type-Size Total Total LDPE XLPE AWG/KCMIL Stranding LDPE XLPE LDPE XLPE CAVOLINIA $1, $1, /0-7 ACSR 1-6/ NRC , NASSA $1, $1, /0-7 AAC 2/ NRC , RUNCINA * $1, $1, /0-7 ACSR 2/0-6/ NRC * 1, DUNGENESE $1, $1, / / NRC , TROPHON $1, $1, /0-19 AAC 2/ NRC , TRITON $1, $1, /0-19 ACSR 2/0-6/ NRC , CYCLOPS $1, $1, / / NRC , FULGUR $1, $1, / / NRC , MURSIA $2, $2, /0-19 ACSR 3/0-6/ NRC , FLUSTRA $2, $2, / / NRC , KINGCRAB $2, $2, / / NRC , PORTUNUS $2, $2, /0-19 AAC 4/ NRC , ZUZARA * $2, $2, /0-19 ACSR 4/0-6/ NRC * 1, CERAPUS * $2, $2, /0-19 ACSR 2/0-6/ NRC * 1, LEPAS $2, $3, / / NRC , ARCA $2, $2, / / NRC , NANNYNOSE $5, $5, AAC NRC ,000 1,096 1,111 LIMPET $5, $6, ACSR / NRC ,000 1,147 1,161 * Stock Products - XLPE Only OHSDC-2
5 Multiplex Overhead Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006 Quadruplex Approx. Net Weight Base Price Power Neutral Lbs. Per 1000 Feet Package Conductor Pounds Per MFT Conductor Messenger Type/Size Footage CODE WORD Size -Stranding Type-Size Total (1) Total LDPE XLPE AWG/KCMIL Stranding LDPE XLPE LDPE XLPE CHOLA $ $ ACSR 6-6/ NRC , $ $ ACSR 6-6/ Coil FRENCH-COACH $ $ NRC , QUARTER $ $ AAC NRC , PINTO $1, $1, AAC NRC , HACKNEY $1, $1, ACSR 4-6/ NRC , $1, $1, ACSR 4-6/ Coil ARABIAN $1, $1, NRC , MUSTANG $1, $1, AAC NRC , PALOMINO * $1, $1, ACSR 2-6/ NRC * 1, $1, $1, ACSR 2-6/ Coil * BELGIAN $1, $1, NRC , CRIOLLO $2, $2, /0-19 AAC 1/ NRC , COSTENA $2, $2, /0-19 ACSR 1/0-6/ NRC , SHETLAND $2, $2, / / NRC , PERCHERON $2, $2, /0-19 AAC 2/ NRC , GRULLO $2, $2, /0-19 ACSR 2/0-6/ NRC , ,014 THOROUGHBRED $2, $3, / / NRC , HANOVERIAN $3, $3, /0-19 AAC 3/ NRC , SUFFOLK $3, $3, /0-19 ACSR 3/0-6/ NRC ,300 1,071 1,086 TROTTER $3, $3, / / NRC ,300 1,009 1,023 OLDENBURG $3, $3, /0-19 AAC 4/ NRC ,100 1,021 1,035 APPALOOSA * $3, $4, /0-19 ACSR 4/0-6/ ,021 1,034 NRC * 1,100 1,130 1,137 WALKING $4, $4, / / NRC ,100 1,057 1,070 SINGLEFOOT $4, $4, /0-7 AAC 4/ NRC ,100 1,040 1,056 STALLION $4, $4, /0-7 ACSR 4/0-6/ ,038 1,053 NRC ,100 1,142 1,158 LIPPIZANER $7, $7, AAC ,245 1,491 1,511 NRC ,100 1,491 1,511 BRONCO $7, $7, ACSR /1 1,245 1,539 1,560 NRC ,000 1,539 1,560 BRETON $7, $7, ,298 1,544 1,565 NRC ,000 1,544 1,565 * Stock Products - XLPE Only OHSDC-3
6 Reverse Twist Secondary Cables Specification ICEA #S Base Price Per MFT Three Conductor RTS Cables: 6201 Alloy Neutral Approx. Phase Conductor Neutral Conductor Net Weight, Package Size and Size and Lbs. Per Type/Size Footage CODE WORD Stranding Stranding Rated 1000 Feet (1) HDPE XLPE AWG/KCMIL AWG/KCMIL Strength Total POPE $1, $1, , NR ,000 AUBURN $2, $2, / , NR ,200 ROCKNE $2, $2, / , NR ,600 DURANT $3, $4, / , NR ,000 Three Conductor RTS Cables: ACSR Neutral EDSEL $1, $1, /6/2001 2, NR ,000 ESSEX $2, $2, /0-7 1/0-6/1 4, NR ,200 CORD $2, $2, /0-7 2/0-6/1 5, NR , Prices for other contructions available on inquiry. OHSDC-RTS
7 600 Volt Underground Single Conductor Distribution Cable Black Cross-Linked Polyethylene Insulated Phase Conductors 90 C Specification ICEA S Refer to Specification Sheet UDS for Product Specifications Conductor Net Weight, Package Base Price Size Lbs. Per Type/Size Footage CODE WORD Per MFT AWG/KCMIL 1000 Feet (1) PRINCETON/XLP $ NRC ,000 MERCER/XLP $ NRC ,000 CLEMSON/XLP $ NRC ,000 KENYON/XLP $ NRC ,000 HARVARD/XLP $ / NRC ,000 YALE/XLP $ / NRC ,000 TUFTS/XLP $ / NRC ,000 BELOIT/XLP $ / NRC ,000 HOFSTRA/XLP $1, NRC ,000 GONZAGA/XLP $1, NRC ,000 RUTGERS/XLP $1, NRC ,000 DARTMOUTH/XLP $2, NRC ,000 EMORY/XLP $2, NRC ,000 DUKE/XLP $3, NRC ,000 FURMAN/XLP $3, NRC ,000 SEWANEE/XLP $3, NRC ,000 FORDHAM/XLP $4, ,114 NRC , Prices for other constructions available on inquiry Single Conductor Approx. Total UDSC-1
8 600 Volt Underground Distribution Cable Black Cross-Linked Polyethylene Insulated Phase Conductors 90 C Extruded Yellow Stripes Specification ICEA S Refer to General Cable Specification #AC-001 for Product Specifications Duplex with a Tristripe Neutral (EYS) Phase Conductor Neutral Conductor Net Weight, Package Base Price Size Size Lbs. Per Type/Size Footage CODE WORD Per MFT AWG/KCMIL AWG/KCMIL 1000 Feet (1) CLAFLIN / XLP * $ NRC * 1,000 DELGADO / XLP $ NRC ,000 EVERETT / XLP $ NRC ,000 Triplex with a Tristripe Neutral (EYS) Approx. ERSKINE / XLP * $ NRC * 1,000 VASSAR / XLP * $1, NRC * 1,000 STEPHENS / XLP * $1, NRC * 1,000 RAMAPO / XLP * $1, NRC * 1,000 BRENAU / XLP * $1, / NRC * 1,000 BERGEN / XLP * $1, /0 1/ NRC * 1,000 FISK / XLP $1, / NRC ,000 CONVERSE / XLP * $1, / NRC * 1,000 HUNTER / XLP $2, /0 2/ NRC ,000 HOLLINS / XLP $2, /0 1/ NRC ,000 ROCKLAND / XLP $2, /0 3/ NRC ,000 SWEETBRIAR / XLP * $2, /0 2/ NRC * 1,000 MONMOUTH / XLP * $2, /0 4/ NRC * 1,000 AQUINAS / XLP $3, / NRC ,000 PRATT / XLP * $3, / NRC ,000 WESLEYAN / XLP * $4, / ,118 NRC * 1,000 NEWARK / XLP $5, ,278 NRC ,000 RIDER / XLP * $6, ,248 1,591 NRC * 1,000 WESTCHESTER / XLP $7, ,384 1,745 NRC ,000 FAIRFIELD / XLP $9, ,850 2,304 NRC ,000 * Stock Products Total UDCD-2
9 600 Volt Underground Distribution Cable Black Cross-Linked Polyethylene Insulated Phase Conductors 90 C Extruded Yellow Stripes Specification: ICEA S Refer to General Cable Specification Sheet #AC-0001 for Product Specifications Quadruplex with a Tristripe Neutral (EYS) Approx. Phase Conductor Neutral Conductor Net Weight, Package Base Price Size Size Lbs. Per Type/Size Footage CODE WORD Per MFT AWG/KCMIL AWG/KCMIL 1000 Feet (1) Total TULSA / XLP $1, NRC ,000 DYKE / XLP * $1, NRC * 1,000 NRC * 1,500 WITTENBERG / XLP $1, NRC ,000 NOTRE DAME / XLP * $2, / NRC * 1,000 PURDUE / XLP $2, /0 1/ NRC ,000 SYRACUSE / XLP $2, / NRC ,000 LAFAYETTE / XLP $2, /0 2/ NRC ,000 SWARTHMORE / XLP $3, /0 1/ NRC ,000 DAVIDSON / XLP $3, /0 3/ NRC ,000 WAKE FOREST / XLP * $3, /0 2/ NRC * 1,000 EARLHAM / XLP $4, /0 4/ ,066 NRC ,000 RUST / XLP $5, / ,176 NRC ,000 SLIPPERY ROCK / XLP * $5, /0 1,166 1,544 NRC * 1,000 NIAGARA / XLP $6, ,294 1,704 NRC ,000 WOFFORD / XLP $8, ,710 2,174 NRC ,000 MARSHALL / XLP $9, ,850 2,332 NRC ,000 WINDHAM / XLP $12, ,542 3,147 NRC ,000 TABOR / XLP $13, ,773 3,440 NRC ,000 * Stock Products UDCD-3
10 600 Volt Underground - Single Conductor Abuse Resistant Distribution Cable Ruggedized C High Density Crosslinked Polyethylene Specification ICEA S Conductor Net Weight, Package Base Price Size Lbs. Per Type/Size Footage CODE WORD Per MFT AWG/KCMIL 1000 Feet (1) PRINCETON-AR $ NRC ,000 MERCER-AR $ NRC ,000 CLEMSON-AR $ NRC ,000 KENYON-AR $ NRC ,000 HARVARD-AR $ / NRC ,000 YALE-AR $ / NRC ,000 TUFTS-AR $ / NRC ,000 BELOIT-AR $ / NRC ,000 HOFSTRA-AR $1, NRC ,000 GONZAGA-AR $1, NRC ,000 RUTGERS-AR $1, NRC ,000 DARTMOUTH-AR $2, NRC ,000 EMORY-AR $2, NRC ,000 DUKE-AR $3, NRC ,000 FURMAN-AR $3, NRC ,000 SEWANEE-AR $3, NRC ,000 FORDHAM-AR $4, ,117 NRC ,000 Single Conductor Approx. Total ALHSC-1
11 600 Volt Underground Abuse Resistant Distribution Cable Ruggedized C High Density Crosslinked Polyethylene Specification ICEA S Approx. Phase Conductor Neutral Conductor Net Weight, Package Base Price Size Size Lbs. Per Type/Size Footage CODE WORD Per MFT AWG/KCMIL AWG/KCMIL 1000 Feet (1) CLAFLIN-AR $ NRC ,000 DELGADO-AR $ NRC ,000 ERSKINE-AR * $ NRC * 1,000 VASSAR-AR $1, NRC ,000 STEPHENS-AR * $1, NRC * 1,000 RAMAPO-AR $1, NRC ,000 BRENAU-AR * $1, / NRC * 1,000 BERGEN-AR $1, /0 1/ NRC ,000 CONVERSE-AR * $1, / NRC * 1,000 HUNTER-AR $2, /0 2/ NRC ,000 HOLLINS-AR $2, /0 1/ NRC ,000 ROCKLAND-AR $2, /0 3/ NRC ,000 SWEETBRIAR-AR * $2, /0 2/ NRC * 1,000 MONMOUTH-AR $2, /0 4/ NRC ,000 PRATT-AR $3, / NRC ,000 WESLEYAN-AR * $4, / ,116 NRC * 1,000 NEWARK-AR $6, ,275 NRC ,000 RIDER-AR * $7, ,248 1,576 NRC * 1,000 WESTCHESTER-AR $7, ,384 1,727 NRC ,000 VILLANOVA-AR $9, ,706 2,140 NRC ,000 SETON HALL-AR $12, ,080 2,580 NRC ,000 * Stock Products Duplex with a Tristripe Neutral (EYS) Triplex with a Tristripe Neutral (EYS) Total ALHD-2
12 600 Volt Underground Distribution Cable Ruggedized C High Density Crosslinked Polyethylene Specification ICEA S Quadruplex with a Tristripe Neutral (EYS) Approx. Primary Pac Phase Conductor Neutral Conductor Net Weight, Package Base Price Size Size Lbs. Per Type/Size CODE WORD Per MFT AWG/KCMIL AWG/KCMIL 1000 Feet (1) TULSA-AR $1, NRC DYKE-AR $1, NRC WITTENBERG-AR $1, NRC NOTRE DAME-AR $2, / NRC PURDUE-AR $2, /0 1/ NRC SYRACUSE-AR $2, / NRC LAFAYETTE-AR $2, /0 2/ NRC SWARTHMORE-AR $3, /0 1/ NRC DAVIDSON-AR $3, /0 3/ NRC WAKE FOREST-AR * $3, /0 2/ NRC * Total NRC EARLHAM-AR $4, /0 4/ ,062 NRC RUST-AR $5, / ,171 NRC NRC SLIPPERY ROCK-AR $6, /0 1,166 1,538 NRC NIAGARA-AR $6, ,294 1,699 NRC WOFFORD-AR $8, ,710 2,156 NRC MARSHALL-AR $9, ,850 2,312 NRC * Stock Products ALHD-3
13 Service Cable Covered Line Wire Weatherproof Conductor Standards: Insulated Cable Engineers Association (ICEA) -- S Base Price Approx. Net Weight Package Conductor Pounds CODE Per MFT CONDUCTOR Size and Lbs. Per 1000 Feet Type/Size Footage WORD TYPE Stranding Total (1) Total LDPE XLPE AWG/KCMIL LDPE XLPE LDPE XLPE APRICOT $ $ AAC NRC , BUTTERNUT $ $ ACSR 4-6/ NRC , HICKORY $ $ ACSR 4-7/ NRC , PEACH $ $ AAC NRC , PIGNUT $ $ ACSR 2-6/ NRC , QUINCE $ $ AAC 1/ NRC , ALMOND $ $ ACSR 1/0-6/ NRC , OILNUT $ $ / NRC , ORANGE $ $ AAC 2/ NRC , PECAN $ $ ACSR 2/0-6/ NRC , WATERASH $ $ / NRC , FIG $1, $1, AAC 3/ NRC , FILBERT $1, $1, ACSR 3/0-6/ NRC ,900 1,131 1,186 OLIVE $1, $1, AAC 4/ NRC , BUCKEYE $1, $1, ACSR 4/0-6/ NRC ,000 1,080 1,125 PLANETREE $1, $1, / NRC , MULBERRY $1, $1, AAC NRC , ANONA $1, $1, AAC NRC , ,012 MOLLES $2, $2, AAC NRC , HUCKLEBERRY $2, $2, AAC NRC ,300 1,812 1,888 PAW PAW $3, $3, AAC NRC ,800 1,770 1,840 BREADFRUIT $3, $3, AAC NRC ,500 1,832 1,910 PERSIMMON $4, $4, AAC NRC ,200 1,980 2,570 GRAPEFRUIT $4, $4, AAC NRC ,700 1,950 2,018 CLW-1
14 600 Volt Underground Distribution Cable - Tri Rated Black Cross-Linked Polyethylene Insulated Phase Conductors 90 C Extruded Tristripe Neutral Specification ICEA S Refer to General Cable Specification #AC-001 for Product Specifications Triplex with a Tristripe Neutral (EYS) Approx. Phase Conductor Neutral Conductor Net Weight, Package Base Price Size Size Lbs. Per Type/Size Footage CODE WORD Per MFT AWG/KCMIL AWG/KCMIL 1000 Feet (1) Total VASSAR / USE-2/RHH/RHW-2 $1, NRC ,000 STEPHENS / USE-2/RHH/RHW-2 $1, NRC ,000 RAMAPO / USE-2/RHH/RHW-2 $1, NRC ,000 BRENAU / USE-2/RHH/RHW-2 $2, / NRC ,000 CONVERSE / USE-2/RHH/RHW-2 $2, / NRC ,000 SWEETBRIAR / USE-2/RHH/RHW-2 $3, /0 2/ NRC ,000 MONMOUTH / USE-2/RHH/RHW-2 $3, /0 4/ NRC ,000 PRATT / USE-2/RHH/RHW-2 $4, / NRC ,000 WESLEYAN / USE/2-RHH/RHW-2 $5, / ,118 NRC ,000 Quadruplex with a Tristripe Neutral (EYS) SLIPPERY ROCK / USE/RHH/RHW-2 $7, /0 1,166 1,544 NRC , Prices for other constructions available on inquiry TRIUDC-1
SERVICE DROP CABLE APPLICATION: PRODUCT FEATURES: STANDARDS:
800-453-5464 sales@kingwireinc.com SERVICE DROP CABLE APPLICATION: DUPLEX: To supply 120 volts aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600
More informationSECONDARY 600 VOLT CABLES
ALUMINUM UNDERGROUND SECONDARY 600 VOLT CABLES Black Crosslinked Polyethylene (XLPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum Underground Secondary 600 Volt Cables:
More informationAdditional Information TRADE NAME PERIWINKLE; STRANDING 7 (PHASE), 6/1 (NEUTRAL); WEIGHT 272 LB PER 1000 FT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4TRIPLEX1500 4 Triplex Periwinkle XLP King Wire Inc. Catalog Number 4TRIPLEX1500 Manufacturer King Wire Inc. Description
More informationCONDUCTOR WESTERN UNITED ELECTRIC SUPPLY
WESTERN UNITED ELECTRIC SUPPLY ACSR BARE ALUMINUM OVERHEAD CONDUCTOR SIZE AVE STRAND AL/STEEL per 1000 DIAMETER () RATED STRENGTH LBS AMPS (1) 240 LB COIL FT 600 LB 30.22 REEL FT 885 LB 36.22 REEL FE 1770
More informationACSR BARE ALUMINUM OVERHEAD CONDUCTOR RATED STRENGTH LBS 240 LB COIL FT AMPS (1) PARTRIDGE / , ,795
CONDUCTOR CONDUCTOR ACSR BARE ALUMINUM OVERHEAD CONDUCTOR STANDARD PACKAGES CODE WORD SIZE AVE STRAND AL/STEEL per 1000 DIAMETER (INCHES) RATED STRENGTH LBS AMPS (1) 240 LB COIL FT 600 LB 30.22 REEL FT
More informationQuadruplex Service Drop
Aluminum Cable Polyethylene or Cross-linked Polyethylene (XLPE) AAC Conductor Detail Description or Construction Conductor Concentric strand or compressed 1350-H19 conductors, Concentric strand AAC, ACSR
More informationALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.
ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES Black Crosslinked High-Density Polyethylene (XLHDPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum
More informationSB ELECTRICAL WIRE
Addendum # 1 for SB-2012-30 ELECTRICAL WIRE Bid Due Date/Time: NOVEMBER 6 TH, 2012 By 2:00 p.m. Submitted By: Page 1 of 6 Advertised in the Claremore Progress October 14, 2012 and October 21, 2012 Invitation
More informationCategory # 1 - Overhead, Primary, & Secondary Conductors
City of Alexandria Bid Proposal # 2214 Open Date - November 27, 2018 Page BF1of BF7 Category # 1 - Overhead, Primary, & Secondary Conductors 1. 2801602110 17,100 LB. CABLE, 477 MCM AAC CONDUCTOR, $ - $
More informationElectric Utility ENERGY PRODUCTS FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION
Electric Utility ENERGY PRODUCTS FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION MARCH 2014 Electric Utility This catalog contains in-depth information on the most comprehensive line of utility products
More informationELE CTR IC UT ILI TY
ELECTRIC UTILITY ENERGY WIRE AND CABLE FOR POWER GENERATION, TRANSMISSION AND DISTRIBUTION september 2012 Electric Utility This catalog contains in-depth information on the most comprehensive line of utility
More informationTop 240 Feeder Schools for ABA Applicants:
Top 240 Feeder Schools for ABA Applicants: 2015 2017 School Code 5812 4837 5219 6882 4833 5206 5233 4007 6003 1592 1839 2660 5813 1324 5828 5814 5816 School Name FLORIDA LOS ANGELES FLORIDA THE OF TEXAS
More informationTC-RHH/RHW-2 USE-2 Copper
TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationKPI // Road Adjustment.15 Neutral Adjustment (.04) Top 50 GP PPP) Conf + Conf Trn.
KPI Basketball Home Adjustment (.16) as of 3/8/14 9:55 AM @KPIsports // http://www.kpisports.wordpress.com Road Adjustment.15 Neutral Adjustment (.04) Top 50 Conf W L Conf + Conf Trn GP Total SOS (w/ Conf
More informationAll-Time Winningest Teams
Thru 2009 All-Time Winningest Teams Victories (Minimum 25 years in Division I) First No. School Season Yrs. Won Lost Tied Pct. 1. Kentucky...1903 106 1,988 635 1.758 2. North Carolina...1911 99 1,984 703
More informationAAC NON- UCF 27 3 Cincinnati 25 7 Tulane 25 8 Tulsa 19 11 Wichita St. 13 17 South Fla. 20 11 SMU 12 16 Houston 17 16 UConn 15 16 Temple 8 22 Memphis 11 19 East Carolina 1 0 12 16 AAC 12 1 0 204 162 8.9000
More informationgrounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2
grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and
More information(OFFICIAL) NITTY-GRITTY (THROUGH GAMES OF February 24, 2019) Men's Basketball. Road Record. Non-Conf. Record SOS
Gonzaga Virginia Duke Houston Kentucky Michigan St. Tennessee North Carolina Michigan Texas Tech Purdue Virginia Tech Wisconsin LSU Iowa St. Buffalo Marquette Nevada Wofford Kansas Maryland Louisville
More information(OFFICIAL) NITTY-GRITTY (THROUGH GAMES OF March 11, 2019) Men's Basketball. Road Record. Non-Conf. Record SOS
Gonzaga Virginia Duke Houston Kentucky Tennessee North Carolina Michigan St. Texas Tech Michigan Virginia Tech Purdue Wofford LSU Wisconsin Buffalo Auburn Nevada Florida St. Kansas Mississippi St. Louisville
More information(OFFICIAL) NITTY-GRITTY (THROUGH GAMES OF March 14, 2019) Men's Basketball. Road Record. Non-Conf. Record SOS
Virginia Gonzaga Duke Houston Kentucky Tennessee North Carolina Michigan St. Michigan Texas Tech Virginia Tech Purdue Wofford LSU Buffalo Wisconsin Auburn Nevada Florida St. Mississippi St. Kansas Louisville
More information(OFFICIAL) NITTY-GRITTY (THROUGH GAMES OF 2019 Final) Men's Basketball. Road Record. Non-Conf. Record SOS
Virginia Gonzaga Duke Kentucky Michigan St. Houston Texas Tech North Carolina Tennessee Michigan Purdue Virginia Tech Auburn Wofford Florida St. LSU Kansas Buffalo Iowa St. Wisconsin Mississippi St. Louisville
More information(OFFICIAL) NITTY-GRITTY (THROUGH GAMES OF January 25, 2019) Men's Basketball. Road Record. Non-Conf. Record SOS
Virginia Gonzaga Michigan St. Duke Michigan Tennessee Houston Kentucky North Carolina Purdue Virginia Tech Louisville LSU Kansas Wisconsin Texas Tech Iowa St. Nevada Marquette Maryland Nebraska Buffalo
More informationThree Year Average NCAA RPI
A&M Corpus Christi 151.3 77 260 136 166 281 319 323 248 210 85 159 Abilene Christian 311.7 325 321 289 Air Force 239.0 29 167 270 245 110 168 79 250 240 226 251 Akron 69.0 68 76 99 89 107 55 42 93 115
More informationHigh Voltage Copper, Smooth Aluminum Shield/Sheath
High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationIntroduction. Nexans wire and cable. Contact us for all your wire and cable needs
Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and
More informationHigh Voltage Aluminum, Smooth Aluminum Shield/Sheath
High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationDLO. Mining Cable. Mining Cable. 2 kv
11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power
More informationSection 11 Mining Cable
11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,
More informationQuintas & Quintas Group
Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors
More informationPRODUCTS COMMERCIAL BUILDING WIRE & CABLE
PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored
More informationCAAI-S 0,6/1 kv with Public Lighting
For overhead secundary distribution networks. Description Application: For urban and rural overhead secundary distribution networks, with voltages up to 1000 V. Construction: 1. Conductor: Aluminium 1350,
More informationFaculty (Full-time & Part-time) - Employed at NJ Institutions by Gender, Fall 2004
Faculty (Full-time & Part-time) - Employed at NJ Institutions by Gender, Fall 2004 Men Women Total N.J. INSTITUTIONS Full-Time Part-Time TOTAL Full-Time Part-Time TOTAL Full-Time Part-Time TOTAL NJ Institute
More informationMedium Voltage Cable. marmonutility.com
Medium Voltage marmonutility.com Table Contents Introduction... 2 Hendrix Product Information... 4 Distribution s (URD) 15kV...6 25kV... 10 35kV...12 28kV...14 Electrical Data...16 Kerite Product Information...
More informationMedium Voltage Cables for PermaLife Nuclear Utility Applications
Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with
More informationSECTION 300 OVERHEAD SERVICE
SECTION 300 OVERHEAD SERVICE 300.01 General Company provides, installs, and maintains service drop to point of delivery approved by Company. Customer provides point of attachment which is acceptable to
More informationMTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...
MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9
More informationVOLUME 27 ISSUE 9 NOVEMBER 17-23, 2015 THE MIDWEEK BEST BETS. MISSOURI over Tennessee by 6
VOLUME 27 ISSUE 9 NOVEMBER 17-23, 2015 College Football 11/21 College Football 11/21 Pro Football 11/22 MEMPHIS over Temple by 13 THE MIDWEEK BEST BETS MISSOURI over Tennessee by 6 MINNESOTA over Green
More informationManufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation
More informationLCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable
ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary
More informationLCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable
ed Primary UD TRXLP ed Primary UD TRXLP Cable Aluminum or Copper Conductor. TRXLP Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for
More informationCorflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3
Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation
More informationMedium Voltage Power Cables
Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables
More informationPOWER. Lengths (ft) Nominal Overall Diameter. Part Number. Gauge /strands
GPT HOOK-UP: round construction wire is made of one, stranded conductor insulated with polyvinyl chloride. Wire used for connecting low voltage power in vehicles, control equipment, RVs and other. Gauge
More informationDRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.
DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,
More informationMINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates
MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment
More informationDATE OPPONENT W/L ALL ALL % BIG 12 BIG
Texas 8/25 at Florida L 0-1 0 8/26 vs. Oregon W 1-1 50 9/01 vs. Villanova W 2-1 66 9/02 vs. Georgia Tech W 3-1 75 9/02 at San Diego W 4-1 80 9/07 TEXAS A&M - CORPUS CHRISTI W 5-1 83 9/07 DENVER W 6-1 85
More informationAFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
More informationis the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.
is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for
More informationTECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV
Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240
More informationHOISTS RATCHET LEVER HOISTS
Yale HOISTS RATCHET LEVER HOISTS Yale PE & RS Ratchet Lever Hoist / to ton capacities Link chain models Light and portable Weatherized load brake Requires less handle pull to lift full load Efficient Yale
More informationYear-by-Year Results. *Denotes home game
156 *Denotes home game 1900-01 Won 2, Lost 2 Head Coach: W.D. Weatherford Captain: Earnest Reese Nashville YMCA* L 19 22 Nashville YMCA* W 24 9 Nashville YMCA* W 14 12 Nashville A.C.* L 11 13 1901-02 Won
More informationBRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER
BRONCO Brand TM Premium Flexible Power Cable PHILATRON WIRE AND CABLE * USA MANUFACTURER WWW.PHILATRON.COM Table of Contents BRONCO-15 Cable & Cord Description To: Bronco-15 From: Bronco-66 History: To
More informationFR-3S Fire Resistant Cables
FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and
More informationElster Perfection Fitting Certification NPGA Southeastern Conference April Jim Hansen Elster Perfection
Elster Perfection Fitting Certification NPGA Southeastern Conference April 2015 Jim Hansen Elster Perfection Piping Materials used in LP Copper - Inexpensive refrigerant tubing is permitted as a piping
More informationELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables
ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable 0.6 / 1kV XLPE Insulated Unarmoured Cables 0.6 / 1kV XLPE Insulated Armoured Cables 1.8 / 3kV XLPE Insulated Armoured Cables 3.6 / 6kV
More informationARMOR-GRIP Suspension: Double
: Double For Line Angles Between 30 and 60 ACSR, All-Aluminum, Aluminum Alloy, AWAC Compacted All-Aluminum Compacted ACSR, ACSS, ACSS/TW Range AGS s AGS AGS s & Min. Max. Nominal Conductor Size s Per Set
More informationVillanova Men's Basketball Villanova Combined Team Statistics (as of Mar 18, 2017) All games
Villanova Combined Team Statistics (as of Mar 18, 2017) Overall record: 32-4 Conf: 15-3 Home: 14-1 Away: 11-2 Neutral: 7-1 Total 3-Point F-Throw Rebounds ## Player gp-gs min avg fg-fga fg% 3fg-fga 3fg%
More informationAAAC - ASTM - B All Aluminium Alloy Conductor
AAAC - ASTM - B All Aluminium Alloy Conductor Eland Product Group: A4A APPLICATION AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require
More informationYale HOISTS. 414 West Broadway Ave. P.O. Box 769 Muskegon, MI PH: FX:
Yale HOISTS! To Avoid Injury: Do not exceed working load limit, load rating, or capacity. Do not use to lift people or loads over people. Read and follow all instructions. 44 West Broadway Ave. P.O. Box
More informationAERIAL. a Nexans company. Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone Cable Sales Phone 1300 CABLES
Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone 613 9281 4444 Cable Sales Phone 1300 CABLES New Zealand Paraite Road Bell Block New Plymouth New Zealand Phone 646 755 9800
More informationSUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L
SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).
More informationWPS SERVICE MANUAL. Section 7 Clearances. 7-1 Basic Electric Clearances - Services Miscellaneous Clearances Antenna Clearances...
Revised 03/2016 Section 7 CLEARANCES Page 1 of 9 Section 7 Clearances 7-1 Basic Electric Clearances - Services... 2 7-2 Miscellaneous Clearances... 7 7-3 Antenna Clearances... 9 Revised 03/2016 Section
More informationWIRE & CABLE OVER A HALF CENTURY OF EXPERTISE
EXPERIENCED. RELIABLE. TRUSTED. QUALITY. WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE KalaS headquarters KalaS los angeles 28365 Constellation Road, Unit B KalaSwIRe.COM P 717.336.5575 RELIABLE DEPENDABLE
More informationINDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES
INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed
More informationPRODUCT CATALOGUE Volume 4
PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationSlack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440)
NOMENCLATURE Material Helical Leg Section: Aluminum covered steel. An aluminum alloy version is available for corrosive environment. Contact PLP. Crossover Marks: Indicates starting point for application
More informationACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)
ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor) The steel reinforced aluminium conductor consists of seven or more aluminium wires applied in concentric layers over a steel core made of one
More informationOFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets
OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationMICRODUCTS FUTUREPATH
FUTUREPATH FEATURES s factory bundled with a polyethylene oversheath: Configurations: 7-way, 4-way, 3-way or 2-way Cost-Effective multiple pathways for one installation cost Ships on a Standard Reel FuturePath
More informationKALAS ENTERTAINMENT CABLE
KALAS ENTERTAINMENT CABLE DELIVERING DEPENDABILITY FOR MORE THAN HALF A CENTURY Kalas is a full-service manufacturer with over 55 years of experience. We are strategically positioned to deliver quality
More informationULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable
ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable SERVING THE NUCLEAR POWER MARKETS power generating plants original equipment manufacturer storage and waste management facilities
More informationRENEWABLE ENERGY. Alcan cable solutions
RENEWABLE ENERGY Alcan cable solutions Renewable Energy Broch_mech5.indd 1 5/23/11 11:02:2 AM Alcan Cable s Commitment: Cabling Solutions for Wind and Solar Farms As the demand for electrical power continues
More informationUNSHIELDED MULTI CONDUCTOR
PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,
More informationVolume 2 Charts, Formulas, and Other Useful Information
Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase
More informationSuperwinch 12 Volt Smart Switch w/ Wireless Remote Kit Installation Instructions
1404 N. Marshall Ave. El Cajon CA. 92020 WLH 08/09/18 514-0141 607-0143 TABLE OF CONTENTS ***Assembly*** ***Parts & Tools*** Wiring the Motor... 1 Smart Switch Basic Kit - Wiring Diagram #514-0141... 5
More informationSPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number
SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS Made from high impact, UV resistant, polyvinyl chloride (PVC), they are non-corrosive and do not abrade the conductor or require
More informationinnerduct Innerduct INNERDUCT tidbit
innerduct Innerduct Innerduct is manufactured from High Density Polyethylene in accordance with the specifications of ASTM F-2160 and/or NEMA TC 7. Other dimensional requirements may be acceptable upon
More informationDIAMETER (PER ANSI/ICEA S )
HQ2000.175" TRXLP 15 KV CONCENTRIC COMPRESSED STRANDING AND SOLID S PHYSICAL DATA Min. Max. Insulation Insulation With 2 SOLID 10 14.258.610.695.978 61.1 130 356 477 2 7 10 14.283.635.720 1.003 62.3 130
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More informationUSA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands
USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands Lapp Kabel, power and control cable, PVC single core for field wiring, UL MTW VW-1, UL AWM style
More informationSection 4 - Protection
Transmission Catalogue : Section 4 Protection Section 4 - Protection Table of Contents Section/Page PREFORMED Armor Rods For AAC, AAAC and ACSR s... 4-3 For AAC, AAAC and ACSR s (Subset)... 4-3 For SC/GZ
More informationPRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH
GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation
More informationA. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.
SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems
More informationDistribution networks : Low Voltage Aerial Cables
Distribution networks : Low Voltage Aerial Cables Energy Infrastructures Generation Transmission - Distribution 050804 Nexans LV ABC & Accessories PK 2 Distribution networks : Low Voltage Aerial Bundled
More informationMaterials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)
XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test
More informationSmart Switch Basic Kit - 24 volt ( ) Wiring Instructions
Smart Switch Basic Kit - 4 volt (54-08) Wiring Instructions NB 8/0/ 6 ga. wire 6 ga. wire 6 ga. wire OUT IN 6 ga. wire Yellow Black Blue 50 AMP BREAKER MOTOR 6 ga. wire 6 ga. wire 6 ga. wire ROCKER SWITCH
More informationLIST OF PUBLISHED STANDARDS
Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for
More informationCORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...
w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths
More informationNew Commercial Service Request-Job Process
New Commercial Service Request-Job Process HILCO Electric Cooperative, Inc. thanks you for the opportunity to be your electric provider. We are committed in providing you the best electric service promptly
More informationChange the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat
Change the 2001.5 and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat This schematic and wiring diagram is to be used only for single stage heating and single
More informationTC-THHN/THWN-2 Copper, PVC/Nylon Insulated
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and
More informationWire Management Products Index
Section T Wire Management Products Index Product Page Number Kellems Wire Mesh Grips T-2 3 Pulling Grips T-4 16 DUA-PULL Grips T-6 DUA-PULL Feed Tube T-6 Overhead Multiple Strength T-7 Underground Pulling
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MM-338 FOOTBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give
More information11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company
More informationAssociated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches.
APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Assessor s Parcel Number (APN) Identifying number assigned by the county assessor s office to each taxable building lot in the
More information