CONDUCTOR WESTERN UNITED ELECTRIC SUPPLY
|
|
- Kory Small
- 5 years ago
- Views:
Transcription
1 WESTERN UNITED ELECTRIC SUPPLY
2 ACSR BARE ALUMINUM OVERHEAD CONDUCTOR SIZE AVE STRAND AL/STEEL per 1000 DIAMETER () RATED STRENGTH LBS AMPS (1) 240 LB COIL FT 600 LB REEL FT 885 LB REEL FE 1770 LB REEL FT 2080 LB REEL FT 3795 LB REEL FT 4160 LB REEL FT 7590 LB REEL FT SWANATE 4 7/ , ,880 8,955 SPARROW 2 6/ , ,695 19,390 SPARATE 2 7/ , ,625 RAVEN 1/0 6/ , ,090 12,180 QUAIL 2/0 6/ , ,830 9,600 PIGEON 3/0 6/ , ,835 7,670 PENQUIN 4/0 6/ , ,040 6,080 WAX WING / ,185 PARTRIDGE / , ,795 MERLIN / , ,695 11,390 LINNETT / , ,205 PELICAN / , ,015 8,030 HAWK / , ,785 11,570 OSPREY / , ,445 6,890 DOVE / , ,955 9,910 DRAKE /7 1, , ,470 6,940 (1) Ampacity for conductor temperature rise of 40 C over 40 2
3 COVERED OVERHEAD TRIPLEX 600 VOLT POLY ALUMINUM INSUL. THICK MILS BARE NEUTRAL MESSENGER RATED STRENGTH LB AMPS (1) per 1000 POLY POLY COILS FT REEL FT REEL SIZE ACSR FULL NEUTRAL MESSENGER VOLUTA / PERIWINKLE / CONCH / NERITINA 1/0 60 1/0-6/ RUNCINA 2/0 60 2/0-6/ MURSIA 3/0 60 3/Ø-6/ ZUZARA 4/0 60 4/0-6/ ACSR REDUCED NEUTRAL MESSENGER COCKLE / JANTHINA 1/ / CAVOLINIA 2/ / AEGA 3/0 60 1/0-6/ CERAPUS 4/0 60 2/0-6/ (1) Ampacity for conductor temperature rise of 35 C over 40 C ambient. COVERED OVERHEAD TRIPLEX 600 VOLT XLP ALUMINUM INSUL. THICK MILS BARE NEUTRAL MESSENGER RATED STRENGTH LB AMPS (1) per 1000 XLP XLP COILS FT REEL FT REEL SIZE ACSR FULL NEUTRAL MESSENGER VOLUTA-XLP / PERIWINKLE-XLP / CONCH-XLP / NERITINA-XLP 1/0 60 1/0-6/ RUNCINA-XLP 2/0 60 2/0-6/ MURSIA-XLP 3/0 60 3/Ø-6/ ZUZARA-XLP 4/0 60 4/0-6/ ACSR REDUCED NEUTRAL MESSENGER COCKLE-XLP / JANTHINA-XLP 1/ / CAVOLINIA-XLP 2/ / AEGA-XLP 3/0 60 1/0-6/ CERAPUS-XLP 4/0 60 2/0-6/ (1) Ampacity for conductor temperature rise of 35 C over 40 C ambient. 3
4 COVERED OVERHEAD QUADRUPLEX 600 VOLT POLY ALUMINUM INSUL. THICK MILS BARE NEUTRAL MESSENGER RATED STRENGTH LB AMPS (1) per 1000 POLY POLY COILS FT REEL FT REEL SIZE ACSR FULL NEUTRAL MESSENGER HACKNEY / PALOMINO / COSTENA 1/ /0-6/ GRULLO 2/ /0-6/ SUFFOLK 3/ /0-6/ APPALOOSA 4/ /0-6/ COVERED OVERHEAD DUPLEX 600 VOLT POLY ALUMINUM SHEPHERD / (1) Ampacity for conductor temperature rise of 35 C over 40 C ambient. COVERED OVERHEAD QUADRUPLEX 600 VOLT XLP ALUMINUM INSUL. THICK MILS BARE NEUTRAL MESSENGER RATED STRENGTH LB AMPS (1) per 1000 XLP XLP COILS FT REEL FT REEL SIZE ACSR FULL NEUTRAL MESSENGER HACKNEY-XLP / PALOMINO-XLP / COSTENA-XLP 1/ /0-6/ GRULLO-XLP 2/ /0-6/ SUFFOLK-XLP 3/ /0-6/ APPALOOSA-XLP 4/ /0-6/ COVERED OVERHEAD DUPLEX 600 VOLT XLP ALUMINUM SHEPHERD-XLP / (1) Ampacity for conductor temperature rise of 35 C over 40 C ambient. 4
5 URD 600 VOLT TRIPLEX XLP ALUMINUM NEUTRAL CONDUCTOR INSULATION THICKNESS IN. STRAND STRAND PHASE NEUTRAL per 1000 DIRECT BURIAL AMPACITY (1) IN CONDUCT FEET REEL SIZE OD REDUCED NEUTRAL STEPHENS BRENAU 1/ CONVERSE 2/ HOLLINS 3/0 19 1/ SWEETBRIAR 4/0 19 2/ PRATT / WESLEYAN / RIDER FULL NEUTRAL RAMAPO BERGEN 1/0 19 1/ HUNTER 2/0 19 2/ ROCKLAND 3/0 19 3/ MONMOUTH 4/0 19 4/ (1) Ampacities are based on 90 C conductor temperature, 20 C ambient earth, and 100% load factor, for Triplex cable buried 36 inches deep, with phase conductors only carrying current. URD 600 VOLT QUADRUPLEX XLP ALUMINUM NEUTRAL CONDUCTOR INSULATION THICKNESS IN. STRAND STRAND PHASE NEUTRAL per 1000 DIRECT BURIAL AMPACITY (1) IN CONDUCT FEET REEL SIZE OD REDUCED NEUTRAL DYKE NOTRE DAME 1/ SYRACUSE 2/ SWARTHMORE 3/0 19 1/ WAKE FOREST 4/0 19 2/ RUST / SLIPPERY ROCK / MORE HOUSE FULL NEUTRAL WITTENBURG PURDUE 1/0 19 1/ LAFAYETTE 2/0 19 2/ DAVIDSON 3/0 19 3/ EARLHAM 4/0 19 4/ (1) Ampacities are based on 90 C conductor temperature, 20 C ambient earth, and 100% load factor, for Triplex cable buried 36 inches deep, with phase conductors only carrying current. 5
6 BARE COPPER WIRE SIZE (AWG OR KCM) STRANDING per 1000 FT (LBS) INDIVIDUAL DIAMETER (MILS) COMPLETE HARD-DRAWN MIN. ULTIMATE STRENGTH (LBS) MEDIUM \HARD- DRAWN MIN ULTIMATE STRENGTH (LBS) SOFT-DRAWN (ANNEALED) MAX. ULTIMATE STRENGTH (LBS) AMPACITY (1) STRANDED / / / / / / (1) Ampacity based on 75 C ambient temperature; 25 C ambient temperature, 2ft/sec. Wind in sun. SIZE (AWG OR KCM) per 1000 FT (LBS) DIAMETER HARD-DRAWN MIN. ULTIMATE STRENGTH MED. HARD-DRAWN MIN. ULTIMATE STRENGTH SOFT-DRAWN (ANNEALED)MAX. ULTIMATE STRENGTH AMPACITY (1) SOLID (1) Ampacity based on 75 C ambient temperature; 25 C ambient temperature, 2ft/sec. Wind in sun. 6
7 UNDERGROUND DISTRIBUTION PRIMARY CABLE TR-XLP INSULATION (ALUMINUM) OR kcmil COPPER NEUTRAL NO. OF NO. OF WIRE INSUL. +/-.030 APPROXIMATE O.D. (CAN VARY BY MFR) INSUL. SHIELD +/-.050 NEUTRAL THICKNESS APPROX. LB per 1000 WITH INSUL..175 XLP INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - FULL NEUTRAL / / / / / XLP INSULATION-ED TYPE UD.P - 90 C - 133% INSULATION LEVEL - FULL NEUTRAL / / / / / XLP INSULATION-ED TYPE UD-P - 90 C - 100% INSULATION LEVEL - ONE THIRD NEUTRAL / / / / /
8 UNDERGROUND DISTRIBUTION PRIMARY CABLE TR-XLP INSULATION (ALUMINUM) OR kcmil COPPER NEUTRAL NO. OF NO. OF WIRE INSUL. +/-.030 APPROXIMATE O.D. (CAN VARY BY MFR) INSUL. SHIELD +/-.050 NEUTRAL THICKNESS APPROX. LB per 1000 WITH INSUL..220 XLP INSULATION-ED TYPE UD.P - 90 C - 133% INSULATION LEVEL - ONE THIRD NEUTRAL / / / / / kV CLASS CABLE:.260 XLP INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - FULL NEUTRAL / / / / / XLP INSULATION-ED TYPE UD-P - 90 C - 100% INSULATION LEVEL - ONE THIRD NEUTRAL / / / / /
9 UNDERGROUND DISTRIBUTION PRIMARY CABLE TR-XLP INSULATION (ALUMINUM) OR kcmil COPPER NEUTRAL NO. OF NO. OF WIRE INSUL. +/-.030 APPROXIMATE O.D. (CAN VARY BY MFR) INSUL. SHIELD +/-.050 NEUTRAL THICKNESS APPROX. LB per 1000 WITH INSUL..345 XLP INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - FULL NEUTRAL 1/ / / / / XLP INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - ONE THIRD NEUTRAL 1/ / / / /
10 UNDERGROUND DISTRIBUTION PRIMARY CABLE EPR INSULATION (ALUMINUM) OR kcmil COPPER NEUTRAL NO. OF NO. OF WIRE INSUL. +/-.030 APPROXIMATE O.D. (CAN VARY BY MFR) INSUL. SHIELD +/-.050 NEUTRAL THICKNESS APPROX. LB per 1000 WITH INSUL..175 INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - FULL NEUTRAL / / / / / INSULATION-ED TYPE UD.P - 90 C - 133% INSULATION LEVEL - FULL NEUTRAL / / / / / INSULATION-ED TYPE UD-P - 90 C - 100% INSULATION LEVEL - ONE THIRD NEUTRAL / / / / /
11 UNDERGROUND DISTRIBUTION PRIMARY CABLE EPR INSULATION (ALUMINUM) OR kcmil COPPER NEUTRAL NO. OF NO. OF WIRE INSUL. +/-.030 APPROXIMATE O.D. (CAN VARY BY MFR) INSUL. SHIELD +/-.050 NEUTRAL THICKNESS APPROX. LB per 1000 WITH INSUL..220 INSULATION-ED TYPE UD.P - 90 C - 133% INSULATION LEVEL - ONE THIRD NEUTRAL / / / / / kV CLASS CABLE:.260 INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - FULL NEUTRAL / / / / / INSULATION-ED TYPE UD-P - 90 C - 100% INSULATION LEVEL - ONE THIRD NEUTRAL / / / / /
12 UNDERGROUND DISTRIBUTION PRIMARY CABLE EPR INSULATION (ALUMINUM) OR kcmil COPPER NEUTRAL NO. OF NO. OF WIRE INSUL. +/-.030 APPROXIMATE O.D. (CAN VARY BY MFR) INSUL. SHIELD +/-.050 NEUTRAL THICKNESS APPROX. LB per 1000 WITH INSUL..345 INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - FULL NEUTRAL 1/ / / / / INSULATION-ED TYPE UD.P - 90 C - 100% INSULATION LEVEL - ONE THIRD NEUTRAL 1/ / / / /
13 COLORADO Office/ Warehouse 100 Bromley Business Parkway Brighton, CO NEW MEXICO Office/Warehouse 7311 La Morada Place NW Albuquerque, NM Sales Support: (800) Printed 07/14
ACSR BARE ALUMINUM OVERHEAD CONDUCTOR RATED STRENGTH LBS 240 LB COIL FT AMPS (1) PARTRIDGE / , ,795
CONDUCTOR CONDUCTOR ACSR BARE ALUMINUM OVERHEAD CONDUCTOR STANDARD PACKAGES CODE WORD SIZE AVE STRAND AL/STEEL per 1000 DIAMETER (INCHES) RATED STRENGTH LBS AMPS (1) 240 LB COIL FT 600 LB 30.22 REEL FT
More informationSECONDARY 600 VOLT CABLES
ALUMINUM UNDERGROUND SECONDARY 600 VOLT CABLES Black Crosslinked Polyethylene (XLPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum Underground Secondary 600 Volt Cables:
More informationMultiplex Overhead Aluminum Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006
Multiplex Overhead Service Cable Specification ICEA Standard S-76-474 General Cable Specification Sheet #AC-0004 and #AC-0006 Base Price Per MFT Approx. Net Weight Power Neutral Lbs. Per 1000 Feet Package
More informationSERVICE DROP CABLE APPLICATION: PRODUCT FEATURES: STANDARDS:
800-453-5464 sales@kingwireinc.com SERVICE DROP CABLE APPLICATION: DUPLEX: To supply 120 volts aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600
More informationSB ELECTRICAL WIRE
Addendum # 1 for SB-2012-30 ELECTRICAL WIRE Bid Due Date/Time: NOVEMBER 6 TH, 2012 By 2:00 p.m. Submitted By: Page 1 of 6 Advertised in the Claremore Progress October 14, 2012 and October 21, 2012 Invitation
More informationAdditional Information TRADE NAME PERIWINKLE; STRANDING 7 (PHASE), 6/1 (NEUTRAL); WEIGHT 272 LB PER 1000 FT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4TRIPLEX1500 4 Triplex Periwinkle XLP King Wire Inc. Catalog Number 4TRIPLEX1500 Manufacturer King Wire Inc. Description
More informationCategory # 1 - Overhead, Primary, & Secondary Conductors
City of Alexandria Bid Proposal # 2214 Open Date - November 27, 2018 Page BF1of BF7 Category # 1 - Overhead, Primary, & Secondary Conductors 1. 2801602110 17,100 LB. CABLE, 477 MCM AAC CONDUCTOR, $ - $
More informationTECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV
Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240
More informationALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.
ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES Black Crosslinked High-Density Polyethylene (XLHDPE) with and without TRISTRIPE grounded in service wired to innovate TM Alcan Aluminum
More informationQuadruplex Service Drop
Aluminum Cable Polyethylene or Cross-linked Polyethylene (XLPE) AAC Conductor Detail Description or Construction Conductor Concentric strand or compressed 1350-H19 conductors, Concentric strand AAC, ACSR
More informationLCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable
ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary
More informationPROTECTION ARRESTERS FUSES WILDLIFE
PROTECTION ARRESTERS FUSES WILDLIFE WESTERN UNITED ELECTRIC SUPPLY ARRESTERS IMAGE DESCRIPTION MFR MODEL # MANUFACTURER Arrester Normal Duty, 3kV, 2.55kV MCOV, XFMR Mounting Bracket PDV-65 Optima 217253-7324
More informationTC-RHH/RHW-2 USE-2 Copper
TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationIntroduction. Nexans wire and cable. Contact us for all your wire and cable needs
Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and
More informationMedium Voltage Cable. marmonutility.com
Medium Voltage marmonutility.com Table Contents Introduction... 2 Hendrix Product Information... 4 Distribution s (URD) 15kV...6 25kV... 10 35kV...12 28kV...14 Electrical Data...16 Kerite Product Information...
More informationHigh Voltage Copper, Smooth Aluminum Shield/Sheath
High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationLCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable
ed Primary UD TRXLP ed Primary UD TRXLP Cable Aluminum or Copper Conductor. TRXLP Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for
More informationTOOLS & MISCELLANEOUS
TOOLS & MISCELLANEOUS TABLE OF CONTENTS 2 Flashlights...4-5 Hand Tools...5-9 Cutters...9-10 Grips... 10 Hoists... 10 Tape... 10-12 Gloves... 12 Miscellaneous... 12-15 100 Bromley Business Parkway Brighton,
More informationMedium Voltage Power Cables
Medium Voltage Power s Distribution s (CN s) are suitable for use above ground in open air, in conduit in air, directly buried, in underground duct, or aerially when suspended on a messenger wire. CN cables
More informationgrounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2
grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and
More informationMecklenburg County Common Code Defects
Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,
More informationACSR - ASTM - B Aluminium Conductor Steel Reinforced
SR - ASTM - B Aluminium Conductor Reinforced Eland Product Group: A4A APPLICATION SR conductor consists of a solid or stranded steel core surrounded by strands of aluminium. SR conductor is available in
More informationTC-THHN/THWN-2 Copper, PVC/Nylon Insulated
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and
More informationManufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation
More informationUF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 UF103WG250 10/3 WG Uf Cable-250' Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category
More informationTC-THHN/THWN-2 Copper, PVC/Nylon Insulated
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets
More informationSouthwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SEU43500 4-4-4 Seu Cable-500' Southwire Company Catalog Number SEU43500 Manufacturer Southwire Company Description Copper
More informationDLO. Mining Cable. Mining Cable. 2 kv
11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power
More informationSection 11 Mining Cable
11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationHigh Voltage Aluminum, Smooth Aluminum Shield/Sheath
High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationELE CTR IC UT ILI TY
ELECTRIC UTILITY ENERGY WIRE AND CABLE FOR POWER GENERATION, TRANSMISSION AND DISTRIBUTION september 2012 Electric Utility This catalog contains in-depth information on the most comprehensive line of utility
More informationElectric Utility ENERGY PRODUCTS FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION
Electric Utility ENERGY PRODUCTS FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION MARCH 2014 Electric Utility This catalog contains in-depth information on the most comprehensive line of utility products
More informationMC or MV-105 Copper, TR-XLPE Insulated
MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationCorflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3
Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation
More informationE R C. R E R C ; ; W T E C
WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation
More informationArmorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION
Armorlite Type MC Lightweight Aluminum Interlocked Armor. 600 Volts. Copper Power Conductors. THHN/THWN Insulated Singles. Green Insulated Grounding Conductor. Sizes 14 AWG through 2 AWG. Rated VW-1. APPLICATIONS
More informationMetering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS
Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards
More informationPentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION
PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company
More informationIEEE 1580 TYPE T/N CABLE
1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR
More information11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company
More informationSUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L
SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).
More informationFROM B.C. HYDRO ENCLOSURE (SEE NOTE 4) RIGID CONDUITS (SEE NOTE 8) ALTERNATIVE TO LOAD BARRIER (SEE NOTE 7) SERVICE ENTRANCE ENCLOSURE
FROM B.C. HYDRO FOR OVERHEAD INSTALLATION ONLY DUCT SEAL (SEE NOTE 8) PULL BOX (SEE NOTE 5) PULL BOX (SEE NOTE 5) FROM B.C. HYDRO 7- REVISED NOTES & TABLES ON PAGES,3,4,5,.MARCH AJ - GENERAL REV.MA 08
More informationPRODUCTS COMMERCIAL BUILDING WIRE & CABLE
PRODUCTS COMMERCIAL BUILDING WIRE & CABLE Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored
More informationTHHN10STBRCP1250 THHN 10 STR Brown 1250 CP
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company
More informationVFD CABLES FOR MOTOR AND DRIVE APPLICATIONS
VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD Lean TR VFD Dual TR Servo VFD Combo DS VFD XLPE TR VFD XLPE 2KV TR SAB s VFD cable series has you covered from fractional to 2 HP drives suitable for industrial
More informationMC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category MC122IG 12/2
More informationRENEWABLE ENERGY. Alcan cable solutions
RENEWABLE ENERGY Alcan cable solutions Renewable Energy Broch_mech5.indd 1 5/23/11 11:02:2 AM Alcan Cable s Commitment: Cabling Solutions for Wind and Solar Farms As the demand for electrical power continues
More informationType MMV-WP Medium Voltage Wind Power Cable
WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationThe Reliable Choice. Field Pocket Guide
The Reliable Choice Field Pocket Guide Allowable Ampacities of STABILOY Brand XHHW-2 and Copper 75 C (167 F) 90 C (194 F) 75 C (167 F) 90 C (194 F) Conductor Size (AWG or kcmil) Types RHW, THHW, THW, THWN,
More informationCable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0.
Table 12-1: current rating Technical Tables T12 Current ratings basic table ÖLFLEX For cables with a nominal voltage of up to 1000 V and for heat-resistant cables at an ambient temperature of +30 C. You
More informationTable 1. Sample Identification and Comparison Connectors Used in Experiments Sample Conductor Size
Background Information and Purpose Underground cable electrical collection systems have become common in renewable generation system applications (wind farms and solar farms). However, the nature of these
More informationINSULATORS CATALOGUE 2016
INSULATORS CATALOGUE 201 SUSPENSION INSULATORS Porcelain Insulator ANSI 52.1 52.4 52.3 Catalog IL&C52-1 IL&C52-4 IL&C52-3 Dimensions (In.) Leakage Distance 7 11-1/2 11-1/2 Dry Among Distance 4.5 7.8 7.8
More information0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR
TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationDAÂY THEÙP MAÏ KEÕM XOAÉN (DAÂY CHOÁNG SEÙT)
DAÂY THEÙP MAÏ KEÕM XOAÉN (DAÂY CHOÁNG SEÙT) GROUND ZINC COATED STEEL WIRE (TK) JIS G 3537 : 1994 danh ñònh Nominal area Keát caáu ructure tính toaùn toång Troïng löôïng gaàn ñuùng Approx. weight nhoû
More informationMC, THHN/THWN-2 Copper
MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are
More informationNEC 2014 Code Changes
NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other
More informationGP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY
TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners
More informationMTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...
MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9
More information0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.
TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING
More informationQuintas & Quintas Group
Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors
More informationDRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.
DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,
More informationMedium Voltage Cables for PermaLife Nuclear Utility Applications
Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with
More informationOutdoor Power Transmission & Distribution
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:
More informationCONDUCTOR CONDUCTOR. Overhead Electric Distribution Standards INTRODUCTION
INTRODUCTION 1. In order to ensure safety, certain minimum clearances shall be maintained between various circuits of an overhead distribution system. Proper clearances from joint-use utilities, railroads,
More informationSuspension Clamps. performance
Suspension Clamps performance Suspension Clamps Index olted/aluminum CFS... Corona Free Clamp for Use With Armor Rods...-3 CFS (ONG)... Corona Free Clamp for Use Without Armor Rods...-4 CFSHT... Corona
More information4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60
4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)
More informationSlack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440)
NOMENCLATURE Material Helical Leg Section: Aluminum covered steel. An aluminum alloy version is available for corrosive environment. Contact PLP. Crossover Marks: Indicates starting point for application
More informationDIAMETER (PER ANSI/ICEA S )
HQ2000.175" TRXLP 15 KV CONCENTRIC COMPRESSED STRANDING AND SOLID S PHYSICAL DATA Min. Max. Insulation Insulation With 2 SOLID 10 14.258.610.695.978 61.1 130 356 477 2 7 10 14.283.635.720 1.003 62.3 130
More informationEasy-On II Terminations
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional
More information11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company
More informationPRODUCT CATALOGUE Volume 4
PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road
More informationLoadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.
3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200
More informationCORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...
w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC
More informationUNSHIELDED MULTI CONDUCTOR
PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,
More informationJumpers & Load Pickup Tools
Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV
More informationTHE RIGHT SOLUTION FOR EVERY APPLICATION
VFD ABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLIATION Products Added VFD Lean TR VFD Dual TR Servo VFD ombo DS VFD XLPE TR VFD XLPE 2KV TR Also Included! FLEXIBLE ONTROL ONTINUOUS FLEX SILIONE
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More informationSpring Test 10 due 05/11/2013
Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock
More informationELECTRICAL MATERIAL BID TABULATION for 2014 CITY OF ST. MARYS WESCO
(1) WATT-HOUR METERS PATH MASTER Item 1 Class 200,V120, Form 12S $59.00 $106.00 Item 2 Class 200, V240, Form 2S $28.00 $90.00 Manufacturer Landis & Gyr Elster (2) WATT-HOUR DEMAND METERS 30 min. demand
More informationGexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company
Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global
More information600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:
Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections
More informationWIRE & CABLE OVER A HALF CENTURY OF EXPERTISE
EXPERIENCED. RELIABLE. TRUSTED. QUALITY. WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE KalaS headquarters KalaS los angeles 28365 Constellation Road, Unit B KalaSwIRe.COM P 717.336.5575 RELIABLE DEPENDABLE
More informationQuick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description
Quick Splice II 5461 (CN) Cable (JCN) Cable 35 kv Molded Rubber Inline Splicing Kit Data Sheet Accessory Splice Jacket 1. Product Description The 3M 5461 Quick Splice II is a 35 kv class inline splice
More informationProduct Number
Sealing and Grounding Cold Shrink cable accessory sealing kits are designed to seal the end of JCN cable. Use these kits when installing elbows or other cable accessories that do not include a jacket seal.
More informationGQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY
TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged
More informationElectrical Tech Note 106
Electrical Tech Note 106 Biosystems & Agricultural Engineering Department Michigan State University Master Exam Study Guide and Sample Questions 1 Based on the 2014 NEC, Part 8 of PA 230, PA 407, and the
More informationUrgent Support to the Agriculture and Electricity Sector in the Gaza Strip
Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract
More informationDISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual
POWER PROTECTION Series 600 UPS Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz Installation Manual TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.............................................1 1.0
More informationPSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.
More informationJOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations
Underground Cable Accessories JOSLYN Table of Contents JPT/JIPT Polymer Terminations 15kV, 25kV & 35kV ShrinkTite Sealing Kits 1kV In-Line Splice Sealing Kit Cable Jacket Sealing Kit Easy-On II Terminations
More informationACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)
ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor) The steel reinforced aluminium conductor consists of seven or more aluminium wires applied in concentric layers over a steel core made of one
More informationCAAI-S 0,6/1 kv with Public Lighting
For overhead secundary distribution networks. Description Application: For urban and rural overhead secundary distribution networks, with voltages up to 1000 V. Construction: 1. Conductor: Aluminium 1350,
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More information