1 Pow-R-Stock Plus quick selector reference guide Frequently used distribution and control products available from distributor stock
2 Table of contents Pow-R-Stock panelboards uestions to ask... 5 Catalog ing... 6 Interiors, EZ Boxes and EZ Trims... 8 Branch circuit breakers Universal main circuit breaker kits top or bottom mounting Lug kits and accessories Safety switches/ disconnects uestions to ask...14 Catalog ing...15 General-duty safety switches...16 Heavy-duty safety switches...17 Safety switch kits...18 Transformers uestions to ask Catalog ing General-purpose transformers Sizing tables ETON
3 Enclosed control uestions to ask Catalog ing NEM non-combination, non-reversing starters, Type NEM combination, non-reversing starters, non-fusible disconnect, Type NEM accessories Lighting contactors Pushbutton stations and pushbuttons uestions to ask mm pushbutton stations mm pushbutton stations Individually packaged 30 mm pushbuttons and operators ETON 3
4 Manual starters uestions to ask...32 Manual motor switches without overload...33 Single-phase manual starter with overload protection Single- and manual starters with overload protection ETON
5 uestions to ask 1 Select an interior 2 What is your voltage? 120/240 V single-phase, three-wire 208Y/120 V, four-wire 480Y/277 V, four-wire What is your busbar rating? 100 (aluminum or copper) 225 (aluminum or copper) 400 (aluminum or copper) 600 (aluminum or copper) What is the of branch circuits/poles? Enclosure type What enclosure is required? NEMT 1 indoor NEM 3R outdoor 3 Trim type 4 For NEM 1 indoor panels, will the panel be mounted recessed in the wall or mounted directly to the wall? Flush Surface What is the cable entry locations for the incoming feeder? Top Bottom 5 Main device Main lugs only (MLO) or main circuit breaker? MLO MCB (choose amperage and top or bottom) Pow-R-Stock panelboards (unassembled) ETON 5
6 Catalog ing system Pow-R-Stock panelboard interiors PRL X 42 S Panel type PRL1 = PRL1a PRL2 = PRL2a Phase 1 = Single-phase 3 = Three-phase Bus amperes 100 = = = = 600 Main device L = MLO provisions only, not applicable for main breaker (only applicable for 225 ) X = No main/use main breaker or main lug kit Number of circuits 18, 30 and 42 Bus type = luminum bus C = Copper bus Option S = Short no TFL or SFB provisions L = Long with TFL or SFB provisions, only applicable for 600 panels Special note: This option applies only to 42 circuit 225 interiors. Note: Top-feed provision for main lugs or main breaker, no provision for through-feed lugs or sub-feed breaker. 6 ETON
7 Catalog ing system EZ Panel factory-assembled stock panelboards P T E T 30 C S ssembled = ssembled completely by factory Trim type F = Flush S = Surface W = Weatherproof (NEM 3R) Panel type P1 = PRL1a P2 = PRL2a Bus type = luminum C = Copper Phase 3 = Three-phase Main lug/breaker amperes 100 = = = = = 400 Number of circuits 30 = 30 circuits 42 = 42 circuits Sub-feed device F = Sub-feed breaker provision T = Through-feed lugs Incoming location B = Bottom T = Top Main device E = Main breaker ED F = Main breaker FD H = Main breaker HFD H = Main breaker HKD at 400 K = Main breaker KD L = Main lug These items are not part of the initial launch. Please consult VIST or your Eaton sales engineer for product availability. NNotes: Not all combinations may be valid. Please verify availability of catalog created. Refer to P014007EN for more information on the EZ Panel. ETON 7
8 Pow-R-Stock panelboards EZE Boxes and EZ Trims mpere rating Max. of poles Capability Main lugs Main Throughbreaker feed lugs Sub-feed breaker (225 max.) Catalog s Interiors (less main device) luminum bus Single-phase, three-wire 120/240 Vac n n n N/ PRL11100X n n n 100 PRL11100X n n n N/ PRL11100X n n n 100, 125, 150, PRL11225X30 175, 200, n n N/ N/ PRL11225X42S n n n 100, 125, 150, PRL11225X42 175, 200, n n N/ N/ PRL11400X42S n n n 100, 125, 150, PRL11400X42 175, 200, n n n N/ n n n 100, 125, 150, 175, 200, 225, 250, 300, 350, 400 Three-phase, four-wire 208Y/120 Vac n n n N/ PRL13100X n n n 100 PRL13100X n n n N/ PRL13100X n n n 100, 125, 150, PRL13225X30 175, 200, n N/ N/ N/ PRL13225L42S n n N/ N/ PRL13225X42S n n n 100, 125, 150, PRL13225X42 175, 200, n n N/ N/ PRL13400X42S n n n 100, 125, 150, PRL13400X42 175, 200, n n n N/ n n n 100, 125, 150, 175, 200, 225, 250, 300, 350, 400 Three-phase, four-wire 480Y/277 Vac n n n N/ PRL23100X n n n 100 PRL23100X n n n N/ PRL23100X n n n 100, 125, 150, PRL23225X30 175, 200, n N/ N/ N/ PRL23225L42S n n N/ N/ PRL23225X42S n n n 100, 125, 150, PRL23225X42 175, 200, n n N/ N/ PRL23400X42S n n n 100, 125, 150, PRL23400X42 175, 200, n n n N/ n n n 100, 125, 150, 175, 200, 225, 250, 300, 350, 400 S = Short no TFL or SFB provisions. 8 ETON
9 Boxes Trims (NEM 1) Copper bus NEM 1 Surface Flush NEM 3R enclosures PRL11100X18C EZB2036R EZT2036S EZT2036F GWPB2036PR PRL11100X30C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL11100X42C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL11225X30C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL11225X42CS EZB2048R EZT2048S EZT2048F GWPB2048PR PRL11225X42C EZB2060R EZT2060S EZT2060F GWPB2060PR PRL11400X42CS EZB2060R EZT2060S EZT2060F GWPB2060PR PRL11400X42C EZB2072R EZT2072S EZT2072F GWPB2072PR PRL11600X42C EZB2072R EZT2072S EZT2072F GWPB2072PR PRL11600X42CL EZB2090R EZT2090S EZT2090F GWPB2090PR PRL13100X18C EZB2036R EZT2036S EZT2036F GWPB2036PR PRL13100X30C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL13100X42C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL13225X30C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL13225L42CS EZB2042R EZT2042S EZT2042F GWPB2042PR PRL13225X42CS EZB2048R EZT2048S EZT2048F GWPB2048PR PRL13225X42C EZB2060R EZT2060S EZT2060F GWPB2060PR PRL13400X42CS EZB2060R EZT2060S EZT2060F GWPB2060PR PRL13400X42C EZB2072R EZT2072S EZT2072F GWPB2072PR PRL13600X42C EZB2072R EZT2072S EZT2072F GWPB2072PR PRL13600X42CL EZB2090R EZT2090S EZT2090F GWPB2090PR PRL23100X18C EZB2036R EZT2036S EZT2036F GWPB2036PR PRL23100X30C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL23100X42C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL23225X30C EZB2048R EZT2048S EZT2048F GWPB2048PR PRL23225L42CS EZB2042R EZT2042S EZT2042F GWPB2042PR PRL23225X42CS EZB2048R EZT2048S EZT2048F GWPB2048PR PRL23225X42C EZB2060R EZT2060S EZT2060F GWPB2060PR PRL23400X42CS EZB2060R EZT2060S EZT2060F GWPB2060PR PRL23400X42C EZB2072R EZT2072S EZT2072F GWPB2072PR PRL23600X42C EZB2072R EZT2072S EZT2072F GWPB2072PR PRL23600X42CL EZB2090R EZT2090S EZT2090F GWPB2090PR NNote: The colors shown in the tables correspond to the color coding on the trim, interior and box product packaging labels. Be sure that all three parts match when delivering to your customer. NNote: Distributors can purchase boxes in quantities via the Distributor toolbox. ETON 9
10 Branch circuit breakers Summary of branch breakers available Breaker No. of poles mpere rating Voltage kic rating Example Panel type BB B BB1020 PRL1a / BB2020 PRL1a BB2040H PRL1a BB3030H PRL1a BF BF1020 PRL1a BHF BHF1020 PRL1a BCF BCF1020 PRL1a BHCF BHCF1020 PRL1a BGFT BGFT1020 PRL1a / BGFT2040 PRL1a BHGFT BHGFT1020 PRL1a / BHGFT2020 PRL1a BGFEP BGFEP1020 PRL1a / BGFEP2020 PRL1a BHGFEP BHGFEP1020 PRL1a / BHGFEP2020 PRL1a BHW BHW1020 PRL1a / BHW2020 PRL1a BHW2040H PRL1a BHW3030H PRL1a GH GH1020 PRL2a GHB B GHB1020 PRL2a Y/ GHB2040 PRL2a Y/ GHB3060 PRL2a BB, BHW, GH and GHB breakers installed in PRL1a and PRL2a are available with shunt trip, i.e., BB1020S. B BB-H and GHB available as chassis-mounted main device. 10 ETON
11 Universal main circuit breaker kits top or bottom mounting Kits main circuit breaker (includes circuit breaker and terminals) Max. mpere volt. rating Service 240 Vac 480 Vac 480 Vac 480 Vac Breaker frame Mounting location Wire range I/Cu (in kcmil) Catalog 100 Single- or ED Universal (1) #14 1/0 BKED Single- or ED Universal (1) #4 4/0 BKED Single- or ED Universal (1) #4 4/0 BKED Single- or ED Universal (1) #4 4/0 BKED Single- or ED Universal (1) #4 4/0 BKED Single- or ED Universal (1) #4 4/0 BKED Single- or FD Universal (1) #14 1/0 BKFD Single- or FD Universal (1) #4 4/0 BKFD Single- or FD Universal (1) #4 4/0 BKFD Single- or FD Universal (1) #4 4/0 BKFD Single- or FD Universal (1) #4 4/0 BKFD Single- or FD Universal (1) #4 4/0 BKFD Single- or FD Universal (1) #4 4/0 BKFD Single- or HFD Universal (1) #14 1/0 BKHFD Single- or HFD Universal (2) #4 4/0 BKHFD Single- or HFD Universal (2) #4 4/0 BKHFD Single- or HFD Universal (2) #4 4/0 BKHFD Single- or HFD Universal (2) #4 4/0 BKHFD Single- or HFD Universal (2) #4 4/0 BKHFD Single- or HFD Universal (2) #4 4/0 BKHFD Single- or KD Universal (1) BKKD Single- or KD Universal (1) BKKD Single- or KD Universal (1) BKKD Single- or KD Universal (2) 3/0 250 or (1) 3/0 500 BKKD400 Order optional lug kit catalog no. 3T225FDK for ED- and FD-Frame three-pole circuit breakers to provide terminations for (1) #6 300 kcmil. NNote: KD kits are to be used on 400 and 600 panels only. ETON 11
12 Universal main circuit breaker kits top or bottom mounting Kits main circuit breaker (includes circuit breaker and terminals) Max. mpere volt. rating Service 480 Vac 480 Vac Breaker frame Mounting location Wire range I/Cu (in kcmil) Catalog 250 Single- or HKD Universal (1) BKHKD Single- or HKD Universal (1) BKHKD Single- or HKD Universal (1) BKHKD Single- or HKD Universal (1) BKHKD Single- or LG Universal (1) #2 500 BKLGE Single- or LG Universal (2) #2 500 BKLGE Single- or LG Universal (2) #2 500 BKLGE ETON
13 Lug kits and accessories Standard main/sub-feed breaker lug capacities mpere rating Lug wire range l/cu 100 (1) #14 1/ (1) #4 4/ (1) kcmil 400 (2) 3/0 250 kcmil or (1) 3/0 500 kcmil Main/through-feed lug kits mpere rating Wire range l/cu Catalog 100 (1) #14 1/0 LUGKIT (1) #6 300 kcmil LUGKIT (2) #2 500 kcmil LUGKIT (2) #2 500 kcmil LUGKIT600 Kits Catalog Description /600 Service entrance kit MLO SEK1/2 SEK1/2 SEK4/6 Service entrance kit MCB SEKB BD SEKF DE SEKKL DF SEKG CD 200% neutral kit 2NK100 2NK225 1NK400 Sub-feed breaker adapter 225SFBKIT (used to mount 225 sub-feed breaker in 400 panels) Sub-feed breaker adapter 225BSFBKIT (used to mount 225 sub-feed breaker in 600 panels) Sub-feed breaker adapter 400SFBKIT (used to mount 400 sub-feed breaker in 600 panels) pplicable for use with MLO, SE panels only. B Only applicable for SE PRL1a with chassis-mounted BB, BH main breaker. C Only applicable for SE PRL2a with chassis-mounted GHB main breaker. D Main breaker panels only includes barrier kit and bonding jumper. E To be used with F-frame main breaker. F To be used with K- and L-frame main breaker. ccessories Description Catalog Isolated ground bar kit ISOGROUND Copper ground bar kit CUGROUND 1P filler plate 5155C62H01 Series rating kit B SRK Each PRS panel comes with 50% filler plates, e.g., 18 circuit interior contains 9 filler plates. B Series rating kit includes series rating book and adhesive sleeve and series rating sticker. If panelboard is being series rated higher than the base rating, an SRK is required. ETON 13
14 uestions to ask Which type of switch do you need? Heavy-duty (DH) General-duty (DG) Double-throw (DT) What current (ampere) rating do you need? 30, 60, 100, 200, 400, 600, 800, 1200 Should it be fused, non-fused or fusible with neutral? How many poles? F = Fusible without neutral U = Non-fusible N = Fusible with neutral 1, 2, 3, 4, 6 Choose the maximum circuit voltage. 240 Vac 600 Vac What type of enclosure do you need? NEM 1 NEM 3R NEM 12 NEM 4 painted steel NEM 4X stainless steel NEM 4X non-metallic 14 Safety switches/ disconnects ETON
15 Catalog ing system safety switches DH N D K Switch type DG = Generalduty DH = Heavy-duty DT = Double-throw Poles/blades 1 = 1 pole 2 = 2 poles 3 = 3 poles 4 = 4 poles 6 = 6 poles Voltage 1 = 120 Vac 2 = 240 Vac 6 = 600 Vac mperes 1 = 30 2 = 60 3 = = = = = = 1200 Fusible/non-fusible or neutral F = Fusible without neutral U = Non-fusible N = Fusible with neutral NEM enclosure ratings C = NEM 4X Non-metallic G = NEM 1 P = NEM 4 Painted steel R = NEM 3R W = NEM 4X Stainless steel Series K = Design all general-duty switches above 200 and all heavy-duty switches incorporate K-Series switch design B = Design general-duty ETON 15
16 General-duty safety switches (disconnects) Two-pole 240 Vac (suitable for service entrance use with a neutral or ground kit) Max. hp ratings Current rating Single-phase Enclosure Catalog (amps) Type type 120 Vac 240 Vac 30 Fusible with neutral NEM DG221NGB 30 Non-fusible NEM DG221UGB 30 Fusible with neutral NEM 3R DG221NRB 30 Non-fusible NEM 3R 2 3 DG221URB 60 Fusible with neutral NEM DG222NGB 60 Non-fusible NEM DG222UGB 60 Fusible with neutral NEM 3R 3 10 DG222NRB 60 Non-fusible NEM 3R 1 10 DG222URB 100 Fusible with neutral NEM DG223NGB 100 Non-fusible NEM 1 15 DG223UGB 100 Fusible with neutral NEM 3R DG223NRB 100 Non-fusible NEM 3R 15 DG223URB Three-pole 240 Vac (suitable for service entrance use with a neutral or ground lug kit) Current rating (amps) Type Enclosure type Max. hp ratings Singlephase Threephase 240 Vac 240 Vac Catalog 30 Fusible with neutral NEM DG321NGB 30 Non-fusible NEM DG321UGB 30 Fusible with neutral NEM 3R DG321NRB 30 Non-fusible NEM 3R DG321URB 60 Fusible with neutral NEM DG322NGB 60 Non-fusible NEM DG322UGB 60 Fusible with neutral NEM 3R DG322NRB 60 Non-fusible NEM 3R DG322URB 100 Fusible with neutral NEM DG323NGB 100 Non-fusible NEM DG323UGB 100 Fusible with neutral NEM 3R DG323NRB 100 Non-fusible NEM 3R DG323URB Maximum hp ratings for fusible units apply only when dual element time-delay fuses are used. Neutral and ground lug kits Description Neutral kit for 30 switches Neutral kit for switches Ground lug kit for switches Catalog DG030NB DG100NB DG030GB Class R fuse adapter kits mpere rating Type Voltage Catalog 30 General-duty 240 DG30RB 60 General-duty 240 DS16FK 100 General-duty 240 DG100RB 16 ETON
17 Heavy-duty safety switches (disconnects) Three-pole Vac (suitable for service entrance use with a neutral or ground lug kit below) Current rating (amps) Type Enclosure type Max. hp ratings Singlephase Threephase 480 V 600 V 480 V 600 V Catalog 30 Fusible NEM DH361FGK 30 Non-fusible NEM DH361UGK 30 Fusible NEM 3R DH361FRK 30 Non-fusible NEM 3R DH361URK 30 Fusible NEM 4X DH361FWK 30 Non-fusible NEM 4X DH361UWK 60 Fusible NEM DH362FGK 60 Non-fusible NEM DH362UGK 60 Fusible NEM 3R DH362FRK 60 Non-fusible NEM 3R DH362URK 60 Fusible NEM 4X DH362FWK 60 Non-fusible NEM 4X DH362UWK 100 Fusible NEM DH363FGK 100 Non-fusible NEM DH363UGK 100 Fusible NEM 3R DH363FRK 100 Non-fusible NEM 3R DH363URK 100 Fusible NEM 4X DH363FWK 100 Non-fusible NEM 4X DH363UWK 200 Fusible NEM DH364FGK 200 Non-fusible NEM DH364UGK 200 Fusible NEM 3R DH364FRK 200 Non-fusible NEM 3R DH364URK 200 Fusible NEM 4X DH364FWK 200 Non-fusible NEM 4X DH364UWK For 30 switches requiring Class J fusing, switch must be ordered with the Class J clips from the factory by adding a suffix J on the end. ETON 17
18 Safety switch kits Neutral and ground lug kits Description Neutral kit for switches Neutral kit for 100 switches Neutral kit for 200 switches Ground lug kit for switches Ground lug kit for 200 switches Catalog DH030NK DH100NK DG200NK DS100GK DS200GK factory-installed ground lug is supplied on all NEM 4, 4X and 12 safety switches, as well as all 400 and higher NEM 1 and 3R safety switches. factory-installed ground lug is also supplied on all heavy-duty NEM 1 and 3R switches that do not have a factory installed neutral. Class R fuse adapter kits mpere rating Type Voltage Catalog 30 Heavy-duty 600 DS16FK 60 Heavy-duty 600 DS26FK 100 Heavy-duty 600 DS36FK 200 Heavy-duty 600 DS346FK Class J fuse adapter kit mpere rating Type Voltage Catalog 60 Heavy-duty 600 DS26JK 30 switches must be ordered from the factory with Class J fuse provisions by adding suffix J at the end of the switch catalog. 100 and 200 switches can be field modified by moving the load side fuse base. 18 ETON
19 uestions to ask How many phases? Single-phase Three-phase What type of enclosure is required? Ventilated Encapsulated What is the primary voltage? (input voltage) Single-phase is 240 V x 480 V Three-phase is 480 V delta (, three-wire) What is the secondary voltage? (output voltage) Single-phase 120/240 Three-phase 208Y/120 (, four-wire) or 240 V delta What kv transformer is required? If single-phase encapsulated, kvs are: 0.05, 0.075, 0.1, 0.15, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 25, 37.5 If single-phase ventilated, kvs are: 15, 25, 37.5, 50, 75, 100, 167 If encapsulated, kvs are: 3, 6, 9, 15, 30, 45, 75 If ventilated, kvs are: 15, 30, 45, 75, 112.5, 150, 225, 300 If a ventilated transformer was selected Field kits: lug kits or weathershields Select from selection tables Transformers ETON 19
20 Catalog ing system DOE 2016 ventilated transformers V 48 M 28 T Type T = DS-3 (single-phase ventilated) V = DT-3 ( ventilated) Primary voltage 20 = 240 x = 480 Taps D = 2@+2.5%, 2@ 2.5% G = 2@ 5% L = 2@ 5%X 4@ 2.5% M = 2@+2.5%,4@ 2.5% N = None P = 1@+5%, 2@ 5%X 2@+2.5%,4@ 2.5% Secondary voltage 11 = 120/ = 208Y/ = 240 V delta with 120 V lighting tap 15 = = = = = 45 Phase S = Single-phase T = Three-phase kv 50 = = = = = = = = 300 DOE 10 CFR = DOE 2016 efficiency Suffix options Blank = luminum windings CU = Copper windings ES = Shielded Typically used with single-phase transformers. 20 ETON
21 Catalog ing system encapsulated transformers S 20 N 11 S 05 Type S = EP (single-phase encapsulated) Y = EPT ( encapsulated) Primary voltage 20 = 240 x = 480 Taps D = 2@+2.5%, 2@ 2.5% G = 2@ 5% L = 2@ 5%X 4@ 2.5% M = 2@+2.5%,4@ 2.5% N = None P = 1@+5%, 2@ 5%X 2@+2.5%,4@ 2.5% Secondary voltage 11 = 120/ = 208Y/ = 240 V delta with 120 V lighting tap Phase and shield S = Single-phase T = Three-phase P = Epoxy potted B E = Shielded 81 = = = = = = = = 1 16 = = 2 03 = 3 kv 05 = 5 06 = 6 07 = = 9 10 = = = = = = = 75 Model Model ( Z) omitted when additional suffixes are used Suffix options Blank = luminum windings B = 80 C temperature rise CU = Copper windings Typically used with single-phase transformers. B Single-phase kv encapsulated transformers only. ETON 21
22 General-purpose transformers Three-phase ventilated, 480 delta 208 Y/120, 150 C rise, aluminum windings, DOE 2016 kv Frame Wiring Typical diagram Weathershield lug kit Catalog B WS57 LKS1 V48M28T B WS58 LKS1 V48M28T B WS58 LKS1 V48M28T B WS59 LKS2 V48M28T7516 B B WS60 LKS2 V48M28T1216 B B WS60 LKS3 V48M28T4916 B B WS61 LKS3 V48M28T B WS62 LKS3 V48M28T3316 Suitable for use with wall-mounted bracket WMB05. B Suitable for use with wall-mounted bracket WMB04. Three-phase ventilated, 480 delta 240/120 lighting tap, 150 C rise, aluminum windings, DOE 2016 kv Frame Wiring Typical diagram Weathershield lug kit Catalog B WS57 LKS1 V48M22T B WS58 LKS1 V48M22T B WS58 LKS1 V48M22T B WS59 LKS2 V48M22T7516 B B WS60 LKS2 V48M22T1216 B B WS60 LKS3 V48M22T4916 B B WS61 LKS3 V48M22T B WS62 LKS3 V48M22T3316 Suitable for use with wall-mounted bracket WMB05. B Suitable for use with wall-mounted bracket WMB04. Three-phase encapsulated, 480 delta 208 Y/120, 115 C rise kv Frame Wiring diagram Catalog Y48G28T03N Y48G28T06N Y48G28T09N B Y48D28T15N Y48M28T30N Y48M28T45N Y48M28T75N NNote: For frame drawings and wiring diagrams, refer to 22 ETON
23 General-purpose transformers Single-phase ventilated, 240 x /240, 150 C rise, aluminum windings, DOE 2016 kv Frame Wiring Typical diagram Weathershield lug kit Catalog X WS45 LKS1 T20P11S X WS45 LKS1 T20P11S X WS43 LKS1 T20P11S X WS43 LKS2 T20P11S X WS44 LKS2 T20P11S X WS44 LKS3 T20P11S WS13 LKS3 T48P11S6716 B Suitable for use with wall-mounted bracket WMB01. B 480 V primary only. Single-phase encapsulated 240 x /240, 115 C rise kv Frame Wiring diagram Catalog S20N11S81N S20N11S85N S20N11S82N S20N11S83N P 3 S20N11P26P P 3 S20N11P51P P 3 S20N11P76P 1 67P 3 S20N11P01P P 3 S20N11P16P 2 68P 3 S20N11P02P S20N11S03N S20N11S05N S20N11S07N S20N11S10N S20N11S15N S20L11S25N S20L11S37 NNote: For frame drawings and wiring diagrams, refer to ETON 23
24 General-purpose transformers sizing tables Three-phase transformer full load current Rated line line voltage kv NNote: Line current = (kv x 1000) / (line voltage x 1.732). Single-phase transformer full load current Rated line line voltage kv NNote: Line current = (kv x 1000) / line voltage. 24 ETON
25 uestions to ask What type of enclosure do you need? NEM 1 (general-duty) NEM 3R (rain-tight) NEM 12 (dust-tight) NEM 4X (wash-down) What type of starter do you need? NEM non-combination NEM combination, non-fusible or fusible NEM combination, breaker Lighting contactor What is the horsepower and voltage of the motor? (Note: this will determine the NEM starter size) Horsepower: 1, 5, 10, 25 hp etc. Motor voltage: 200, 230, 460, 575 V What is the control voltage for the coil? 120 Vac 240 Vac 480 Vac What size overload relay is needed? 1 5 FL 4 20 FL 9 45 FL What additional accessories do you need? Cover control kits, such as HND/OFF/UTO selector switch or STOP/STRT pushbuttons CPT kits Fuse kits Enclosed control ETON 25
26 Catalog ing system non-combination and combination NEM enclosed starters ECN R63/C NEM size = = 0 9 Enclosure type 1 = Type 1 2 = Type 3R 4 = Type 4X 8 = Type 12 Coil voltage = 120 V B = 240 V C = 480 V Class 05 = Non-combination, non-reversing 16 = Combination, non-fusible or fusible, non-reversing 22 = Combination, breaker, non-reversing SSOL rating R63/B = 1 5 FL R63/C = 4 20 FL R63/D = 9 45 FL Disconnect fuse clip rating = None non-fusible B = 30 / 250 V C = 30 / 600 V D = 60 / 250 V E = 60 / 600 V Cover control = None B = Start/stop pushbuttons H = HO selector switch Starters NEM non-combination, non-reversing starters, Type 1 NEM size Motor voltage Maximum hp rating Magnet coil voltage SSOL range Catalog , / ECN051-R63/B ECN051-R63/B 0 200, ECN0501-R63/B ECN0501-R63/B 200, ECN0501-R63/C ECN0501-R63/C 1 200, / ECN0511-R63/C ECN0511-R63/C 2 200, ECN0521-R63/D ECN0521-R63/D NEM combination, non-reversing starters, non-fusible disconnect Type 1 NEM size Motor voltage Maximum hp rating Magnet coil voltage SSOL range Catalog , / ECN161-R63/B ECN161-R63/B 0 200, ECN1601-R63/B ECN1601-R63/B 200, ECN1601-R63/C ECN1601-R63/C 1 200, / ECN1611-R63/C ECN1611-R63/C 2 200, ECN1621-R63/D ECN1621-R63/D 26 ETON
27 Starters NEM enclosures with CPT modifications To order an enclosure with CPT: 1. Change ECN05 to ECN07 for non-combination units, and ECN16 to ECN18 for combination units. 2. Change the in the 7th catalog string to the correct letter based on the below table: Catalog string letter Primary Secondary E 208/60 120/60 B 240/ /440 wired for 240 V 120/60 110/50 C 240/ /440 wired for 480 V 120/60 110/50 NEM accessories CPT and fuse kits Description Catalog 100 V CPT kit (208/277 V primary, 120 V secondary) C341CE 100 V CPT kit (240/480 V primary, 120 V secondary) C341CC Fuse clip kit for combination starter 30 / 250 V C351KC21 Fuse clip kit for combination starter 30 / 600 V C351KD22-61 and 60 / 250 V NEM accessories cover control kits Description Catalog Noncombination Type 1, size 00 2 Noncombination Type 1, size 3 5 Combination Type 1 and all Type 3R, 12, 4X STOP/STRT pushbuttons C600M1 C400GK1 C400T1 STOP/STRT pushbuttons C600M101 C400GK12 with red RUN light ( Vac) HND/OFF/UTO C600M12 C400GK3 C400T12 selector switch HND/OFF/UTO selector switch with red RUN light ( Vac) C600M121 C400GK32 ETON 27
28 Catalog ing system enclosed lighting contactors ECL 03 C 1 2 Contactor type C = C30CN L = CN35 and 202 Class 03 = Non-combination, electrically held contactors 04 = Non-combination, mechanically held contactors mperes = 10 B = 20 C = 30 D = 60 E = 100 Enclosure type 1 = Type 1 2 = Type 3R 4 = Type 4X 8 = Type 12 Coil voltage = 120 V B = 240 V C = 480 V Poles 2 9 = 2 9 poles required = 10 poles required B = 12 poles required D = 20 poles required Disconnect ratings = None Lighting contactors Lighting non-combination contactors, Type 1 Contactor type Number of poles mpere rating Coil voltage Catalog C30CN, electrically held ECC03C12 C30CN, electrically held ECC03C14 C30CN, electrically held ECC03C16 CN35, electrically held ECL03B12 CN35, electrically held ECL03B14 CN35, electrically held ECL03B16 28 ETON
29 uestions to ask Do you need an assembled pushbutton station or loose components in clam-shell packaging? For pushbutton stations ssembled pushbutton station Loose components in clam-shell package What size of pushbutton station do you need? 22 mm 30 mm How many elements (operators) do you want? For loose components What type of operator do you need? Emergency stop operator Momentary pushbutton Indicating light Illuminated pushbutton Selector switches Pushbutton stations and pushbuttons ETON 29
30 Pushbutton stations 30 mm pushbutton stations Description Single-element Emergency Off break glass pushbutton station, NC Man-Off-uto selector switch pushbutton station, 2NO Stop mushroom head pushbutton station, 1NC Two-element Start-Stop pushbutton station, 1NO-2NC Start-Stop rectangular pushbutton station, 1NO-1NC Catalog 10250TGR 10250T T T H5200 Three-element Open-Close-Stop pushbutton station, 2NO-3NC 10250T3614 Up-Down-Stop rectangular pushbutton station, 2NO-1NC 10250H mm pushbutton stations Description Single-element 40 mm mushroom head push-pull emergency stop operator, NC 40 mm illuminated mushroom head push-pull emergency stop operator, Vac, NO-NC Two-element Flush pushbutton, Start-Stop, NO-NC Flush pushbutton, Forward-Reverse, 2NO Three-element Flush pushbutton, Open-Stop-Close, 2NO-1NC Flush pushbutton, Forward-Stop-Reverse, 2NO-1NC Flush pushbutton, Up-Stop-Down, 2NO-NC Catalog M22-C1-M1H M22-C1-M2H M22-C2-M2V M22-C2-M3V M22-C3-M4V M22-C3-M5V M22-C3-M6V 30 ETON
31 Pushbutton components Individually packaged 30 mm pushbuttons and operators NEM 4, 4X, Description Emergency stop operator Red non-illuminated push-pull, 1NO-1NC, includes 2 legend plates: EMERG. STOP and STOP Jumbo mushroom pushbutton, 1NO-1NC, button engraved EMERG. STOP (button is engraved no legend plate provided) Red mushroom pushbutton engraved EMERG. STOP, 1NO-1NC, includes 2 legend plates: EMERG. STOP and STOP Momentary pushbutton Black flush pushbutton, 1NO-1NC, includes 1 legend plate: STRT and JOG Red extended pushbutton, 1NO-1NC, includes 1 legend plate: STOP Indicating light Red indicating light transformer 120 Vac with two extra lenses (green and amber), 1NO-1NC, includes 2 legend plates: RUN and JOG Illuminated pushbutton Red illuminated pushbutton (120 Vac/Vdc),with 2 extra lenses (green and amber), 1NO-1NC, includes 1 legend plate: Power On Selector switches Two-position selector switch, 1NO-1NC, includes 3 legend plates: Off/On, Hand/uto and Run/Jog Three-position selector switch, 2NO-2NC, includes 1 legend plate: Hand/Off/uto Three-position selector switch, 1NO-1NC, includes 1 legend plate: Hand/Off/uto Catalog 10250T5B62-1-POP 10250T33-POP 10250T32R-POP 10250T30B-POP 10250T31R-POP 10250T34R-POP 10250T411C21-1-POP 10250T20KB-POP 10250T22KB-POP 10250T21KB-POP ETON 31
32 uestions to ask What is the motor nameplate information? System (C or DC) and voltage? If C, is the motor single-phase or? What is the motor horsepower? What type of enclosure is needed? No enclosure (will be mounted in separate enclosure) NEM 1 enclosure Is overload protection required? No Yes. If yes, what is the motor full load amperes (FL)? What type of operator does the customer want? Button Toggle 32 Manual starters ETON
33 Manual starters Manual motor switches without overload Type Pole config. Maximum motor (hp) Catalog 120 V 240 V 480 V 230 V Open Enclosed B230 Two-pole 2 5 B230N B230G B230B Two-pole B230BND B230BGD Three-pole B330ND B330GD Single-phase manual starters with overload protection Type MS series starters Maximum motor (hp) C voltage Catalog Pole config. 120 Vac 240 Vac 277 Vac Open Enclosed B Single-pole MST01 MST01SN1P Two-pole MST02 MST02SN1P Maximum motor (hp) DC voltage Catalog Pole config. 120 Vdc 240 Vdc 32 Vdc Open Enclosed B Single-pole ¼ ¼ ¼ MST01 MST01SN1P Two-pole ¼ ¼ ¼ MST02 MST02SN1P Use MSH heaters for MS series starters. B With pilot light. Single- and manual starters with overload protection Type B100 Pole config. NEM size Maximum motor (hp) C voltage Catalog Vac 240 Vac Vac Open Enclosed B Two-pole B100M0B B100S0B (single-phase) B100M1B B100S1B Three-pole () B100M0C B100S0C 1 3 7½ 10 B100M1C B100S1C Pole config. NEM size Maximum motor (hp) DC voltage Catalog 115 Vdc 230 Vdc Open Enclosed B Two-pole 0 1 1½ B100M0B B100S0B (single-phase) 1 1½ 2 B100M1B B100S1B Three-pole 0 B100M0C B100S0C () 1 B100M1C B100S1C Use FH heaters for Type B100 starters. B NEM 1. ETON 33
34 Product contact information Call 877-ETN-CRE ( ) Notes: 34 ETON
35 ETON 35
36 * t Eaton, we believe that power is a fundamental part of just about everything people do. Technology, transportation, energy and infrastructure these are things the world relies on every day. That s why Eaton is dedicated to helping our customers find new ways to manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. To improve people s lives, the communities where we live and work, and the planet our future generations depend upon. Because that s what really matters. nd we re here to make sure it works. See more at Eaton.com/whatmatters For more information, visit Eaton.com/powrstock Eaton is a registered trademark. ll other trademarks are property of their respective owners. Eaton 1000 Eaton Boulevard Cleveland, OH United States Eaton.com 2018 Eaton ll Rights Reserved Printed in US Publication No. C E / Z20429 February 2018
Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers
uick selector reference guide Pow-R-Stock panelboards, safety switches, and transformers Table of contents Pow-R-Stock panelboards uestions to ask... 5 Catalog numbering... 6 Interiors, EZ boxes, and trims...
More informationUnassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims
Unassembled Pow-R-Stock EZE Boxes and EZ Trims Single-Phase, -Wire 10/40 Catalog Number Interiors (Less Main Device) mpere Max. No. of Poles luminum Bus Copper Bus 0 18 PRL110X18 PRL110X18C 0 0 PRL110X0
More informationWiring Diagram Number
General-Purpose Encapsulated Transformers.4 Single-Phase Encapsulated Type EP, 60 Hz 77 Volts to 10/40 Volts 1 Full Capacity Taps kva FCAN FCBN Type 40 x 40 Volts to 10/40 Volts Full Capacity Taps kva
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationQuick selector reference guide. Motor Control Center Aftermarket Buckets
Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview
More informationPanelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description
.5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,
More informationEOEM panelboard and switchboard (OPS) Program
Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit
More informationSubmittal Transmittal
Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/12/2011 Reference
More informationPanelboard Renewal Parts Supplement
Panelboard Renewal Parts Supplement Contents Page Page Contents Page PRL 1a and a Neutral Assemblies..................................................... 3 PRL 1a and a Ground Assemblies.......................................................
More information3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...
.6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone
More information1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch
. Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A
More informationECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9
February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR
More informationSmall Project Product Selection Guide
Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationFeatures, Benefits and Functions
-8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor
More informationSUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM:
OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: SUBJECT: MOTOR CONTROL BUILDING REFERENCE: DATE RECIEVED: Oct 09, 204 DISCIPLINE: Electrical PRIORITY STATUS: 2-STANDARD SPECIFICATION REF: 26 29 REVIEWER DUE DATE:
More informationPANELBOARDS SECTION 1
SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector
More information1.3 Enclosed Rotary Disconnects Product Overview... Product Selection... Dimensions...
DH362NRK Safety Switch. Product Overview........................................ Cross-Reference...................................... Selection............................... Options and Accessories................................
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationSwitching Devices. 1.2 Enclosed Circuit Breakers. 1.3 Enclosed Rotary Disconnects
Switching Devices DH362NRK Safety Switch. Product Overview......................................... V2-T-2 General Duty............................................. V2-T-24 Heavy-Duty..............................................
More informationFor Options, Modifications and Accessories, see pages Discount Schedule A6
Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationPlug and Play Kit Installation and Wiring (Non-Combo and Combo)
General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationPanelboards Circuit Breaker / Lighting and Distribution
Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationContents. Product Overview
.1 Switching Devices Rotary Disconnect F-Frame Fusible Product Overview Product Selection Guide Safety Switch Contents Description Page Product Overview Standards and Certifications.......................
More information1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationOperation and Maintenance manual. fusible shunt trip switch
Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse
More information4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering
Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant
More information1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch
Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A
More information331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH
331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing
More information4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...
.5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,
More informationLaser Service Factory-assembled Panelboards
Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page
More informationAmpgard medium voltage motor control renewal parts
Technical Data TD020001EN Contents Description Page General information.... 2 3 400A starter design.... 4 9 800A starter design.... 10 15 Control and potential transformers.... 16 Current transformers....
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationNEMA Vacuum Break Contactors and Starters
NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More information4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection...
.1 Contents Description Catalog Number Selection................ Enclosures............................ Cover Control.......................... Product Selection.................... Operation Non-Combination
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More information6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum
.1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor
More informationQuik-Spec Coordination Panelboard A fusible panelboards
Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationSafety Switch. Type VBII. cross-reference GUIDE
Safety Switch Type VBII cross-reference GUIDE General Duty 240 Volt, Type 1 (Indoor) 2-Pole, 2-Wire, Fusible 2-Pole, 3-Wire, Fusible 3-Pole, 3-Wire, Fusible 3-Pole, 4-Wire, Fusible 30 Use 60 Use Use Use
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationPanelboards and Lighting Controls
Product Guide and Lighting Controls Assembled Unassembled and Lighting Controls and Lighting Control Contents 1.1 Introduction Product Selection... 1-2 1.1 EZ Box and EZ Trim Product Description... 1-4
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationQuik-Spec Coordination Panelboard Specifications
Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY
More informationElectrical Notes: For PDC-1 provide a minimum of 6 spare circuits.
Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Switchboards and Panelboards for the Waynetown Water
More informationSelection and application guide
Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure
More informationVacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components
Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationQuik-Spec Coordination Panelboard A fusible panelboards
USSMNN Supersedes December 2015 SERIES Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications.... 2-3 Enclosure types and voltages/systems.... 4 using, main
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationLighting Contactors. 6.1 Open Control. Product Overview...
Lighting Contactors C30CN Mechanically and Electrically Held.1 Product Overview........................................ C30CN Mechanically and Electrically Held Product Description....................................
More information6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum
. Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 =
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More information9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.
Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More information1.1. Switching Devices. Safety Switches
. Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB
More informationBolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More information6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions
.1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design
More informationPow-R-Line 3E Panelboard
This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided
More information2 SLR Series Line Reactors... 50
Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...
More informationPVGard 600 and 1000 Vdc solar photovoltaic circuit breakers
Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................
More information5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection
.11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box
More informationOverview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8
Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical
More informationLO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating
ing Devices. Modifications Flex Center Introduction The Safety Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized safety that meet
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationEvolution * Series E9000 Motor Control Center
GE Industrial Solutions Evolution * Series E9000 Motor Control Center Renewal Parts Bulletin Table of Contents Introduction The E9000-Line motor control center, a quality product of the General Electric
More informationWARREN COUNTY, N.Y. M/E REFERENCE
SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More information1.1. Switching Devices
. Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More informationDetail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order
Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationTABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:
3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4
More informationALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationCENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies
Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase