Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

Size: px
Start display at page:

Download "Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers"

Transcription

1 uick selector reference guide Pow-R-Stock panelboards, safety switches, and transformers

2 Table of contents Pow-R-Stock panelboards uestions to ask... 5 Catalog numbering... 6 Interiors, EZ boxes, and trims... 7 Branch and main circuit breakers... 8 Safety switches uestions to ask...11 Catalog numbering...1 General-duty safety switches...1 Heavy-duty safety switches...14 Transformers uestions to ask Catalog numbering General-purpose transformers Sizing chart eaton corporation

3 Product contact information Call 877-ETN-CRE ( ) uestions to ask Notes: 1 Select an Interior What is your voltage? Single-phase is -wire /40V Three-phase is 4-wire 08Y/V, -wire 40 or 4-wire 480Y/77 What is your busbar rating? 0 (aluminum or copper) 5 (aluminum or copper) 400 (aluminum or copper) What is the number of branch circuits/poles? Enclosure type Do you need NEMT 1 or R? Indoor or outdoor? If NEM 1, go to trim If NEM R, skip trim and go to main breaker 4 eaton corporation eaton corporation Trim What is the trim type? Main Device Main lug or MCB? Surface Flush mount Select main breaker amperage from options available Pow-R-Stock panelboards

4 Catalog numbering system Pow-R-Stock panelboard interiors PRL1 1 5 X 4 S Panel PRL1 = PRL = PRLa EZT 0 6 S Phase 1 = Single-phase = Three-phase EZB 0 6 R BS NEM 1 Pow-R-Stock Panelboard Trims EZT are available laser cut trims used on all, PRLa, and PRLa panels Width in inches = 0 Height in inches = 6, 48, 60, or 7 Mounting S = Surface F = Flush NEM 1 Pow-R-Stock Panelboard Boxes EZB are available boxes used for all 1, PRLa, and PRLa panels Width in inches = 0 Height in inches = 6, 48, 60, or 7 R = Right-hand flange BK ED 0 T Breaker kit Breaker frame ED or FD or KD Trip rating 0, , 175, 00, 5, 50, 00, 50, 400 Mounting T = Top B = Bottom Bus mps 0 = 0 5 = = 400 Main Device X indicates no main/ use main breaker or main lug kit Number of Circuits 18, 0, and 4 Bus = luminum bus C = Copper bus S = Short no TFL or SFB provisions Special note: This option applies only to 4 circuit 5 interiors. Unassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims Single-Phase, -Wire /40 Catalog Number Interiors (Less Main Device) mpere Max. No. of Poles luminum Bus Copper Bus 0 18 PRL110X18 PRL110X18C 0 0 PRL110X0 PRL110X0C 5 0 PRL115X0 PRL115X0C 5 4 PRL115X4S PRL115X4CS 5 4 PRL115X4 PRL115X4C PRL11400X4 PRL11400X4C Three-Phase, 4-Wire 08Y/ or Three-Phase, -Wire 40 Catalog Number Interiors (Less Main Device) mpere Max. No. of Poles luminum Bus Copper Bus 0 18 PRL10X18 PRL10X18C 0 0 PRL10X0 PRL10X0C 5 0 PRL15X0 PRL15X0C 5 4 PRL15X4S PRL15X4CS 5 4 PRL15X4 PRL15X4C PRL1400X4 PRL1400X4C Three-Phase, 4-Wire 480Y/77 Catalog Number Interiors (Less Main Device) mpere Max. No. of Poles luminum Bus Copper Bus 0 18 PRL0X18 PRL0X18C 0 0 PRL0X0 PRL0X0C 5 0 PRL5X0 PRL5X0C 5 4 PRL5X4S PRL5X4CS 5 4 PRL5X4 PRL5X4C PRL400X4 PRL400X4C Single-Phase, -Wire /40 ; Three-Phase, 4-Wire 08Y/ or Three-Phase, -Wire 40 ; Three-Phase, 4-Wire 480Y/77 Boxes and Trims Boxes Trims (NEMT 1) NEM 1 Surface Flush NEM R Enclosures EZB06R EZT06S EZT06F GWPB06PR EZB048R EZT048S EZT048F GWPB048PR EZB048R EZT048S EZT048F GWPB048PR EZB048R EZT048S EZT048F GWPB048PR EZB060R EZT060S EZT060F GWPB060PR EZB07R EZT07S EZT07F GWPBR07PR NNote:The colors shown in the tables correspond to the color coding on the trim, interior, and box product packaging labels. Be sure all three parts match when delivering to your customer. 6 eaton corporation eaton corporation 7

5 Unassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims Summary of Branch Breakers vailable Breaker Frame BB 1 BB H BGF 1 BHW 1 No. of Poles mpere Voltage / /40 / kic Example BB0 BB00 BB040H BB00H BGF0 BGF040 BHW0 BHW00 BHW040H BHW00H Panel GH GH0 PRLa GHB Y/77 480Y/ GHB0 GHB040 GHB060 Circuit breaker kits unassembled Pow-R-Stock panelboards Kits Main Circuit Breaker (Includes Circuit Breaker and Terminals) Max. Volt mpere Service 15 Single- or 150 Single- or 175 Single- or 00 Single- or 5 Single- or 15 Single- or 150 Single- or 175 Single- or 00 Single- or 5 Single- or Catalog Number Breaker Frame Mounting Location PRLa PRLa PRLa Wire Range I/Cu (in kcmil) BKED0T ED Top (1) #14 1/0 BKED15T ED Top (1) #4 4/0 BKED150T ED Top (1) #4 4/0 BKED175T ED Top (1) #4 4/0 1 BKED00T ED Top (1) #4 4/0 1 BKED5T ED Top (1) #4 4/0 1 BKED0B ED Bottom (1) #14 1/0 BKED15B ED Bottom (1) #4 4/0 BKED150B ED Bottom 1) #4 4/0 BKED175B ED Bottom (1) #4 4/0 1 BKED00B ED Bottom (1) #4 4/0 1 BKED5B ED Bottom (1) #4 4/0 1 Circuit breaker kits unassembled Pow-R-Stock panelboards Kits Main Circuit Breaker (Includes Circuit Breaker and Terminals) Max. Volt mpere Service 15 Single- or 150 Single- or 175 Single- or 00 Single- or 5 Single- or 15 Single- or 150 Single- or 175 Single- or 00 Single- or 5 Single- or 50 Single- or 00 Single- or 50 Single- or 400 Single- or 50 Single- or 00 Single- or 50 Single- or 400 Single- or Catalog Number Breaker Frame Mounting Location 1 Order optional lug kit catalog no. T5FDK for ED- and FD-Frame three-pole circuit breakers to provide terminations for (1) #6 00 kcmil. Wire Range I/Cu (in kcmil) BKFD0T FD Top 1) #14 1/0 BKFD15T FD Top (1) #4 4/0 BKFD150T FD Top (1) #4 4/0 BKFD175T FD Top (1) #4 4/0 1 BKFD00T FD Top (1) #4 4/0 1 BKFD5T FD Top (1) #4 4/0 1 BKFD0B FD Bottom (1) #14 1/0 BKFD15B FD Bottom (1) #4 4/0 BKFD150B FD Bottom (1) #4 4/0 BKFD175B FD Bottom (1) #4 4/0 1 BKFD00B FD Bottom (1) #4 4/0 1 BKFD5B FD Bottom (1) #4 4/0 1 BKKD50T KD Top (1) BKKD00T KD Top (1) BKKD50T KD Top (1) BKKD400T KD Top () /0 50 or (1) /0 500 BKKD50B KD Bottom (1) BKKD00B KD Bottom (1) BKKD50B KD Bottom (1) BKKD400B KD Bottom () /0 50 or (1) / Order optional lug kit catalog no. T5FDK for ED- and FD-Frame three-pole circuit breakers to provide terminations for (1) #6 00 kcmil. 8 eaton corporation eaton corporation 9

6 Circuit breaker kits unassembled Pow-R-Stock panelboards Kits Main Lugs or Through-Feed Lugs mpere Service Catalog Number Wire Range I/Cu 5 Single- or LUGKIT0 (1) #14 1/0 LUGKIT5 (1) #6 00 Kcmil Kits Main Lugs Only mpere Service Catalog Number Wire Range l/cu 400 Single- or LUGKIT400 () # 500 Kcmil Kits Service Entrance mpere Service Catalog Number Panel 0/5 Single- or 400 Single- or SEK1/ SEK4/6 or PRLa or PRLa uestions to ask 1 Which type of switch do you need? Heavy-duty (DH) General-duty (DG) Double-throw (DT) What current (amp) rating do you need? 0, 60, 0, 00, 400, 600, 800, 0 Should it be fused, non-fused, or fusible with neutral? F = Fusible without neutral U = Non-fusible N = Fusible with neutral Kits Insulated/Isolated Ground (Carton ty. of 5) mpere Service Catalog Number Panel 0/5/400 Single- or ISOGROUND or PRLa Kits 00% Neutral mpere Service Catalog Number Panel 5 Single- or NK0 NK5 or PRLa or PRLa How many poles? 1,,, 4, 6 What voltage do you need? What type of enclosure do you need? NEM 1 NEM R NEM 1 NEM 4 painted steel NEM 4x stainless steel NEM 4x non-metallic Safety switches /disconnects eaton corporation eaton corporation 11

7 Catalog numbering system safety switches Switch DG = General duty DH = Heavy duty DT = Double-throw Poles/Blades 1 = 1 pole = poles = poles 4 = 4 poles 6 = 6 poles Voltage 1 = = 40 6 = 600 DH 6 1 N D K mperes 1 = 0 = 60 = 0 4 = 00 5 = = = = 0 Fusible/Non-Fusible or Neutral F = Fusible without neutral U = Non-fusible N = Fusible with neutral NEM Enclosure s C = NEM 4x Non-metallic G = NEM 1 P = NEM 4 Painted steel R = NEM R W = NEM 4x Stainless steel Series K = Design all general-duty switches above 00 and all heavy-duty switches incorporate K-Series switch design B = Design general-duty 0 0 General-duty safety switches (disconnects) Three-Pole 40 (Suitable for Service Entrance Use with a Neutral or Ground Lug Kit) Mfr. s Neutral and Ground Lug Kits Mfr. s DG00NB DG0NB DG00GB Current () Description Enclosure Neutral kit for 0 switches Neutral kit for 60 0 switches Ground lug kit for 0 0 switches Max HP s Single- Phase Max HP s Three- Phase DG1NGB 0 Fusible with neutral NEM DG1UGB 0 Non-fusible NEM DG1NRB 0 Fusible with neutral NEM R DG1URB 0 Non-fusible NEM R 7.5 DGNGB 60 Fusible with neutral NEM DGUGB 60 Non-fusible NEM 1 15 DGNRB 60 Fusible with neutral NEM R DGURB 60 Non-fusible NEM R 15 DGNGB 0 Fusible with neutral NEM DGUGB 0 Non-fusible NEM DGNRB 0 Fusible with neutral NEM R DGURB 0 Non-fusible NEM R eaton corporation eaton corporation 1

8 Heavy-duty safety switches (disconnects) Three-Pole (Suitable for Service Entrance Use with a Neutral or Ground Lug Kit Below) Mfr. s Current () Enclosure Max. HP s Single-Phase Max. HP s Three-Phase 480V 600V 480V 600V DH61FGK 0 Fusible NEM DH61UGK 0 Non-fusible NEM DH61FRK 0 Fusible NEM R DH61URK 0 Non-fusible NEM R DH6FGK 60 Fusible NEM DH6UGK 60 Non-fusible NEM DH6FRK 60 Fusible NEM R DH6URK 60 Non-fusible NEM R DH6FGK 0 Fusible NEM DH6UGK 0 Non-fusible NEM DH6FRK 0 Fusible NEM R DH6URK 0 Non-fusible NEM R DH64FGK 00 Fusible NEM DH64UGK 00 Non-fusible NEM DH64FRK 00 Fusible NEM R DH64URK 00 Non-fusible NEM R Neutral and Ground Lug Kits Mfr. s DH00NK DH0NK DG00NK DS0GK DS00GK Description Neutral kit for 0 60 switches Neutral kit for 0 switches Neutral kit for 00 switches Ground lug kit for 0 0 switches Ground lug kit for 00 switches uestions to ask Transformers 1 How many phases? Single-phase Three-phase What type of enclosure is required? Ventilated Encapsulated What is the primary voltage? (input voltage) Single-phase is 40V x 480V Three-phase is 480V Delta (, -wire) What is the secondary voltage? (output voltage) Single-phase /40 Three-phase 08Y/ (, 4-wire) or 40V Delta What kv transformer is required? If single-phase encapsulated, kvs are: 0.05, 0.075, 0.1, 0.15, 0.5, 0.5, 0.75, 1, 1.5,,, 5, 7.5,, 15, 5, 7.5 If single-phase ventilated, kvs are: 15, 5, 7.5, 50, 75, 0 If encapsulated, kvs are:, 6, 9, 15, 0, 45, 75 If ventilated, kvs are: 15, 0, 45, 75, 11.5, 150, 5, 00, 500 If a ventilated transformer was selected Field kits: Lug kits or weathershields Select from selection tables Transformers 14 eaton corporation eaton corporation 15

9 Catalog numbering system transformers S = EP (single-phase encapsulated) T = DS- (single-phase ventilated) V = DT- ( ventilated) Y = EPT ( encapsulated) Primary Voltage 0 = 40 x = 480 Taps G 5% L 5% X 4@.5% M N = None P = T 0 N 11 S 05 Secondary Voltage 11 = /40 8 = 08Y/ = 40V Delta w/v lighting tap Phase S = Single T = Three 81 = = = 0. 8 = = = = = 1 16 = = 0 = 05 = 5 06 = 6 07 = = 9 kv = 15 = 15 5 = 5 0 = 0 7 = = = = = 0 1 = = = 167 = 5 = = 500 Suffix Options... Z = 1 EE = 1 Model number for encapsulated transformers. NEM TP-1 transformers. Valid only with ventilated transformers. General-purpose transformers Single-Phase Encapsulated 40x480 /40, 115C Rise kv Style Number Outline # 0.05 S0N11S81N S0N11S85N S0N11S8N S0N11S8N S0N11S6N S0N11S51N S0N11S76N 58 1 S0N11S01N S0N11S16N 67 S0N11S0N 68 S0N11S0N S0N11S05N S0N11S07N 178 S0N11SN S0N11S15N S0L11S5N 18 Wiring Diagram 7.5 S0L11S Single-Phase Ventilated, 40x480 /40, 150C Rise, luminum Windings, TP-1 kv Style Number Outline # Wiring Diagram Weathershield Typical Lug Kit 15 T0P11S15EE 816 X WS11 LKS1 5 T0P11S5EE 818 X WS11 LKS1 7.5 T0P11S7EE 818 X WS11 LKS1 50 T0P11S50EE 819 X WS16 LKS 75 T0P11S75EE 80 X WS16 LKS 0 T0P11S99EE 81 X WS1 LKS Three-Phase Encapsulated, Y/, 115C Rise kv Style Number Outline # Wiring Diagram Y48G8T0N Y48G8T06N Y48G8T09N Y48D8T15N 95 7B 0 Y48M8T0N Y48M8T45N Y48M8T75N eaton corporation eaton corporation 17

10 General-purpose transformers Three-Phase Ventilated, 480 Delta 08Y/, 150C Rise, luminum Windings, TP-1 kv Style Number Outline # Wiring Diagram Weathershield Typical Lug Kit 15 V48M8T15EE 91B 80B WS8 LKS1 0 V48M8T0EE 91B 80B WS8 LKS1 45 V48M8T45EE 91B 80B WS8 LKS1 75 V48M8T75EE 914D 80B WS9 LKS 11.5 V48M8T1EE B WS19 LKS 150 V48M8T49EE B WS19 LKS 5 V48M8TEE B WS4 LKS 00 V48M8TEE WS4 LKS 500 V48M8T55EE WS5 LKS4 Three-Phase Ventilated, 480 Delta 40 Delta/ Lighting Tap, 150C Rise, luminum Windings, TP-1 kv Style Number Outline # Wiring Diagram Weathershield Typical Lug Kit 15 V48MT15EE 91B 8B WS8 LKS1 0 V48MT0EE 91B 8B WS8 LKS1 45 V48MT45EE 91B 8B WS8 LKS1 75 V48MT75EE 914D 8B WS9 LKS 11.5 V48MT1EE 916 8B WS19 LKS 150 V48MT49EE 916 8B WS19 LKS 5 V48MTEE 917 8B WS4 LKS 00 V48MTEE 9 8B WS7 LKS 500 V48MT55EE WS5 LKS4 General-purpose transformers Single-Phase Transformer Sizing Chart Rated Line Line Voltage kv N Note: Line current = (kv x 00)/line voltage Three-Phase Transformer Sizing Chart Rated Line Line Voltage kv N Note: Line current = (kv x 00)/(line voltage x 1.7) 18 eaton corporation eaton corporation 19

11 Eaton s electrical business is a global leader in power distribution, power quality, control, and industrial automation products and services. Eaton s global electrical product lines, including Cutler-HammerT, MoellerT, PowerwareT, HolecT, MEMT, SantakT, and MGE Office Protection SystemsE, provide customer-driven PowerChain ManagementT solutions to serve the power system needs of the data center, industrial, institutional, government, utility, commercial, residential, and OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle. With Eaton s distribution, control, and power quality equipment; full-scale engineering services; and information management systems, the power system is positioned to deliver powerful results: greater reliability, operating cost efficiencies, effective use of capital, enhanced safety, and risk mitigation. Eaton Corporation Electrical Sector 1111 Superior ve. Cleveland, OH United States 877-ETN-CRE ( ) Eaton.com 009 Eaton Corporation ll Rights Reserved Printed in US Publication No. C E / Z8 July 009 PowerChain Management is a registered trademark of Eaton Corporation. ll other trademarks are property of their respective owners.

Unassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims

Unassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims Unassembled Pow-R-Stock EZE Boxes and EZ Trims Single-Phase, -Wire 10/40 Catalog Number Interiors (Less Main Device) mpere Max. No. of Poles luminum Bus Copper Bus 0 18 PRL110X18 PRL110X18C 0 0 PRL110X0

More information

Pow-R-Stock Plus quick selector reference guide. Frequently used distribution and control products available from distributor stock

Pow-R-Stock Plus quick selector reference guide. Frequently used distribution and control products available from distributor stock Pow-R-Stock Plus quick selector reference guide Frequently used distribution and control products available from distributor stock Table of contents Pow-R-Stock panelboards uestions to ask... 5 Catalog

More information

Wiring Diagram Number

Wiring Diagram Number General-Purpose Encapsulated Transformers.4 Single-Phase Encapsulated Type EP, 60 Hz 77 Volts to 10/40 Volts 1 Full Capacity Taps kva FCAN FCBN Type 40 x 40 Volts to 10/40 Volts Full Capacity Taps kva

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions Overview Brochure Integrated Power Distribution Medium Voltage Assembly Solutions Medium voltage assembly solutions Eaton, a premier leader in manufacturing power distribution and power protection equipment

More information

Submittal Transmittal

Submittal Transmittal Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/12/2011 Reference

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

EOEM panelboard and switchboard (OPS) Program

EOEM panelboard and switchboard (OPS) Program Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit

More information

Pow-R-Flex low ampere busway

Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway Commercial Industrial Telecommunications Data centers Research Light manufacturing Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway provides

More information

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard... .6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Panelboard Renewal Parts Supplement

Panelboard Renewal Parts Supplement Panelboard Renewal Parts Supplement Contents Page Page Contents Page PRL 1a and a Neutral Assemblies..................................................... 3 PRL 1a and a Ground Assemblies.......................................................

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K Bolted Contact Pringle Switch Cutler-Hammer Bolted Contact Pringle Switch Effective Date March 16, 2009 Replaces TD.02.56.01.T.K 12 Bolted Contact Switch Offering Features 600 volt CSA 480 volt UL DC ratings

More information

X1PB: Explosionproof Panelboards

X1PB: Explosionproof Panelboards X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel

More information

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

1.3 Enclosed Rotary Disconnects Product Overview... Product Selection... Dimensions...

1.3 Enclosed Rotary Disconnects Product Overview... Product Selection... Dimensions... DH362NRK Safety Switch. Product Overview........................................ Cross-Reference...................................... Selection............................... Options and Accessories................................

More information

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Get smart. Reduce energy consumption

Get smart. Reduce energy consumption MEM Electrical sub-distribution Lighting and power metering solutions L2 building regulations compliant Single phase MCB boards Three phase MCB boards MCCB panelboards Get smart. Reduce energy consumption

More information

Consumer Units and the 17th Edition Product Focus. Meet the new regulations How to avoid confusion

Consumer Units and the 17th Edition Product Focus. Meet the new regulations How to avoid confusion Consumer Units and the 17th Edition Product Focus Meet the new regulations How to avoid confusion How to Avoid the Confusion The Rules and Regulations Explained The advent of the New 17th Edition of the

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Panelboards and Lighting Controls

Panelboards and Lighting Controls Product Guide and Lighting Controls Assembled Unassembled and Lighting Controls and Lighting Control Contents 1.1 Introduction Product Selection... 1-2 1.1 EZ Box and EZ Trim Product Description... 1-4

More information

Switching Devices. 1.2 Enclosed Circuit Breakers. 1.3 Enclosed Rotary Disconnects

Switching Devices. 1.2 Enclosed Circuit Breakers. 1.3 Enclosed Rotary Disconnects Switching Devices DH362NRK Safety Switch. Product Overview......................................... V2-T-2 General Duty............................................. V2-T-24 Heavy-Duty..............................................

More information

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type XB IEC Terminal Blocks Screw Type Spring Cage Type Insulation Displacement Connection Type 2 XB IEC Terminal Blocks. Versatility, quality, and reliability. Sometimes it s the little things Eaton knows

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Quick selector reference guide. Motor Control Center Aftermarket Buckets Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

Contents. Product Overview

Contents. Product Overview .1 Switching Devices Rotary Disconnect F-Frame Fusible Product Overview Product Selection Guide Safety Switch Contents Description Page Product Overview Standards and Certifications.......................

More information

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Mining service breakers with true rms sensing designed specifically for trailing cable applications Eaton Mining Service Circuit Breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications E 2 mining service

More information

Panelboards. Panelboards Contents

Panelboards. Panelboards Contents -1 February 7 Contents Description Page EZ Box and EZ Trim.............................................. -2 Product Selection............................................... -4 Product Description.............................................

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits.

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits. Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Switchboards and Panelboards for the Waynetown Water

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

1.1. Switching Devices. Safety Switches

1.1. Switching Devices. Safety Switches . Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB

More information

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection...

1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection... OEM Loadcenters Contents s and Certiications................. Product Selection......................... Page V-T-83 V-T-83 Product s a leader in the electrical distribution equipment business, Eaton has

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards USSMNN Supersedes December 2015 SERIES Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications.... 2-3 Enclosure types and voltages/systems.... 4 using, main

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Safety Switch. Type VBII. cross-reference GUIDE

Safety Switch. Type VBII. cross-reference GUIDE Safety Switch Type VBII cross-reference GUIDE General Duty 240 Volt, Type 1 (Indoor) 2-Pole, 2-Wire, Fusible 2-Pole, 3-Wire, Fusible 3-Pole, 3-Wire, Fusible 3-Pole, 4-Wire, Fusible 30 Use 60 Use Use Use

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Factory Sealed Panelboards

Factory Sealed Panelboards FACTORY SEALED PAELBOARDS Factory Sealed Designed for use In Class I, Division 2 and Class I, Zone 2 areas such as petroleum refineries, chemical or petrochemical facilities, the factory sealed panelboards

More information

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r Generac offers more options for transfer switches than any other manufacturer. The LTS switch is designed to allow for the most efficient

More information

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating ing Devices. Modifications Flex Center Introduction The Safety Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized safety that meet

More information

Three Phase Transformers

Three Phase Transformers Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series

More information

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards Molded Case Selection Guide Replacement s for Eaton Panelboards Molded Case Selection Guide Product Range in Stock and Ready to Go Range KAIC @ 240Vac KAIC @ 277Vac KAIC @ 347Vac KAIC @ 600Vac Terminals

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8 Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical

More information

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards Panelboards Solar Applications.7 Contents Description Introduction.............................. Product Selection Guide.................. EZ Box and EZ Trim........................ Type PRL1a...........................

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Specialty Service Entrance Switchboards. Selection and Application Guide

Specialty Service Entrance Switchboards. Selection and Application Guide Specialty Service Entrance Switchboards Selection and Application Guide Power! As the heart of every business complex it has to be reliable. As part of your business, it has to be economical too.you get

More information

Vintage Westinghouse panelboards

Vintage Westinghouse panelboards Supersedes February 9 PRL1-LX PRL1 / PRL2 PRL CDP, HCDP FDP Contents Description Page Procedure for identifying renewal parts................................................... 2 Distributor ordering instructions.........................................................

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66 -2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 owerlex anelboards: Steel Enclosures Applications The owerlex anelboard provides indoor and

More information

PRODUCT LINE SHEET. Honesty. Integrity. Honor

PRODUCT LINE SHEET. Honesty. Integrity. Honor PRODUCT LINE SHEET Honesty. Integrity. Honor WHO WE ARE At HB, we are dedicated to serving the Electrical Community through the distribution of electrical supplies. We strive to offer the best customer

More information

W-VACi MV circuit breakers

W-VACi MV circuit breakers IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv W-VACi MV circuit breakers A safe choice from a reliable source High-performance Safe and reliable Compact and cost effective Environmentally

More information

Industry s most comprehensive medium voltage circuit protection

Industry s most comprehensive medium voltage circuit protection Medium voltage fuses BUSSMANN SERIES Industry s most comprehensive medium voltage circuit protection We have your solution For over 100 years, Bussmann TM series fuses have provided superior circuit protection,

More information

POWERPLEX PANELBOARD 1

POWERPLEX PANELBOARD 1 1 POWERPLEX PANELBOARD 2 ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Architecture - Engineering - Planning

Architecture - Engineering - Planning rchitecture - Engineering - Planning www.mkcinc.com Mansfield, Ohio New Philadelphia, Ohio Powell, Ohio 419-525-1102 - phone 330-364-8871 - phone 740-657-3202 - phone 419-525-1428 - fax 330-343-3075 -

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards type P Lighting and Power Distribution Panelboards Specifications Main Breaker: 400A Maximum Main Lugs only: 400A Maximum Voltages: 480Y/277V AC Maximum 250V DC Maximum 3Ø3W, 3Ø4W, Ø3W, Ø2W General P panelboards

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Pow-R-Way III Busway Service and Solutions

Pow-R-Way III Busway Service and Solutions Pow-R-Way III Busway Service and Solutions Capabilities Busway Field Measurement Services Final Field Fit Program Express Bus Program Busway Value Calculator Burj Dubai World's tallest building under construction,

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

30 Years of Innovative Solutions for Construction & Industry

30 Years of Innovative Solutions for Construction & Industry 30 Years of Innovative Solutions for Construction & Industry the POWER and light CONSTRUCTION INDUSTRY RENTAL GOVT/MILITARY ENTERTAINMENT 800-678-3470 CEPnow.com Single Phase Power Boxes 6 Outlet - 50

More information

2 SLR Series Line Reactors... 50

2 SLR Series Line Reactors... 50 Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...

More information

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton creates power-engineering

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Vintage Cutler-Hammer Panelboards and Switchboards

Vintage Cutler-Hammer Panelboards and Switchboards Vintage Cutler-Hammer Panelboards and Switchboards Price List PL01400003E Effective January 2008 Supersedes PL01400003E Pages 1 8, Dated February 2004 TABLE 1. CATALOG NUMBERS AND PRICING CATALOG/ STYLE

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

EBMC Combination Line Starters and Enclosures

EBMC Combination Line Starters and Enclosures EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,

More information