2 Bosch Rexroth AG Pneumatics Series 740 Accessories 5/2-way valve, Series 740 Qn = l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into blocks Manual override: without suitable for ATEX 5/2-way valve, Series 740 Qn = l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into blocks Manual override: with detent suitable for ATEX 5/2-way valve, Series 740 CP Qn = 950 l/min pipe connection compressed air connection output: Ø 10x1 Can be assembled into blocks corrosion-protected Manual override: without suitable for ATEX 5/2-way valve, Series 740 CP Qn = 950 l/min pipe connection compressed air connection output: Ø 10x1 Can be assembled into blocks corrosion-protected Manual override: with detent suitable for ATEX Subbases and accessories Fittings - Accessories, Series

3 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 Qn = l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into blocks Manual override: without suitable for ATEX Version Diaphragm poppet valve Pilot internal Sealing principle soft sealing Mounting on manifold strip PRS strip Working pressure min./max. 1.5 bar / 10 bar Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 50 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ Materials: Housing Seals Polyoxymethylene; Polyarylamide Acrylonitrile Butadiene Rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of air pressure must remain constant during the life cycle. Use only the approved oils from Bosch Rexroth, see chapter Technical information. Blocking principle Single base plate principle, Plate principle Nominal flow Qn at 6.3 bar and Δp = 1 bar. with throttle Pilot pressure range Compressed air connection x: Working pressure (bar) y: Pilot pressure (bar) a: Min. pilot pressure at port 14 (Z) depending on working pressure Input Output Exhaust Pilot connection Flow rate value Qn Weight Part No. [l/min] [kg] Ø 8x1 Ø 8x Ø 10x1 Ø 10x1 M14x1 Ø 8x D571_740_a

4 4 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 Qn = l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into blocks Manual override: without suitable for ATEX Dimensions 1) for pipe Ø 8 x 1 2) flow control screw for exhausts 5 (R) and 3 (S) D571_740

5 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 Qn = l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into blocks Manual override: with detent suitable for ATEX Version Diaphragm poppet valve Pilot internal Sealing principle soft sealing Mounting on manifold strip PRS strip Working pressure min./max. 1.5 bar / 10 bar Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 50 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ Materials: Housing Seals Polyoxymethylene Acrylonitrile Butadiene Rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of air pressure must remain constant during the life cycle. Use only the approved oils from Bosch Rexroth, see chapter Technical information. Blocking principle Single base plate principle, Plate 1) See diagram Nominal flow Qn at 6.3 bar and Δp = 1 bar. with throttle Pilot pressure range Compressed air connection x: operating pressure (bar) y: control pressure (bar) a: maximum control pressure depending on operating pressure b: minimum control pressure depending on operating pressure Input Output Exhaust Pilot connection Flow rate value Qn Weight Note Part No. [l/min] [kg] Ø 8x1 Ø 8x Ø 10x1 Ø 10x1 M14x1 Ø 8x ) D571_741_a 5

6 6 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 Qn = l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into blocks Manual override: with detent suitable for ATEX Dimensions 1) for pipe Ø 8 x 1 2) flow control screw for exhausts 5 (R) and 3 (S) 3) position indicator D571_746

7 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 CP Qn = 950 l/min pipe connection compressed air connection output: Ø 10x1 Can be assembled into blocks corrosion-protected Manual override: without suitable for ATEX Version Diaphragm poppet valve Pilot internal Sealing principle soft sealing Mounting on manifold strip PRS strip Working pressure min./max. 2 bar / 10 bar Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 50 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ Materials: Housing Seals Front plate Polyoxymethylene Acrylonitrile Butadiene Rubber Polyarylamide Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of air pressure must remain constant during the life cycle. Use only the approved oils from Bosch Rexroth, see chapter Technical information. Blocking principle Compressed air connection Input Output Exhaust Pilot connection Flow rate value Qn Weight Note Part No. [l/min] [kg] Single base plate principle, Plate principle Ø 10x1 Ø 10x1 M14x1 Ø 8x ) ) See diagram Nominal flow Qn at 6.3 bar and Δp = 1 bar. with throttle Pilot pressure range x: Working pressure (bar) y: Pilot pressure (bar) a: Min. pilot pressure at port 14 (Z) depending on working pressure D571_740_a 7

8 8 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 CP Qn = 950 l/min pipe connection compressed air connection output: Ø 10x1 Can be assembled into blocks corrosion-protected Manual override: without suitable for ATEX Dimensions 1) for pipe Ø 8 x 1 2) flow control screw for exhausts 5 (R) and 3 (S) D571_740

9 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 CP Qn = 950 l/min pipe connection compressed air connection output: Ø 10x1 Can be assembled into blocks corrosion-protected Manual override: with detent suitable for ATEX Version Diaphragm poppet valve Pilot internal Sealing principle soft sealing Mounting on manifold strip PRS strip Working pressure min./max. 2 bar / 10 bar Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 50 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ Materials: Housing Seals Front plate Polyoxymethylene Acrylonitrile Butadiene Rubber Polyarylamide Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of air pressure must remain constant during the life cycle. Use only the approved oils from Bosch Rexroth, see chapter Technical information. Blocking principle Compressed air connection Input Output Exhaust Pilot connection Flow rate value Qn Weight Note Part No. [l/min] [kg] Single base plate principle, Plate principle Ø 10x1 Ø 10x1 M14x1 Ø 8x ) ) See diagram Nominal flow Qn at 6.3 bar and Δp = 1 bar. with throttle Pilot pressure range x: operating pressure (bar) y: control pressure (bar) a: maximum control pressure depending on operating pressure b: minimum control pressure depending on operating pressure D571_746_a 9

10 10 Bosch Rexroth AG Pneumatics 5/2-way valve, Series 740 CP Qn = 950 l/min pipe connection compressed air connection output: Ø 10x1 Can be assembled into blocks corrosion-protected Manual override: with detent suitable for ATEX Dimensions 1) for pipe Ø 8 x 1 2) flow control screw for exhausts 5 (R) and 3 (S) 3) position indicator D571_746

11 Series 740 Accessories Subbases and accessories Ambient temperature min./max. Medium Working pressure min./max. Materials: Subbase Seals Bosch Rexroth AG Pneumatics -15 C / +50 C Compressed air See table below Polyoxymethylene Acrylonitrile Butadiene Rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of air pressure must remain constant during the life cycle. Use only the approved oils from Bosch Rexroth, see chapter Technical information. Type Working pressure min./max. Weight Part No. [kg] Supply plate, complete with O-rings 0 / Supply plate, corrosion-protected, complete with O-rings 0 / Sandwich plate 740, complete with O-rings. 0 / End plate 0 / Dummy flange for reserve places complete with seals 0 / Adapter for separate air supply

12 12 Bosch Rexroth AG Pneumatics Series 740 Accessories Dimensions Tightening torque for all screws max. 35 Nm 1) Inlet plate 2) Through plate 3) End plate 4) Dummy flange 5) Adapter for separate air supply D898_397

13 Series 740 Accessories Fittings - Accessories, Series 740 p893_900 Part No. Type Ø A B C Fig Reducing fitting Ø 8x1 to Ø 6x incl M12x1 Fig. 1 O-ring Reducing fitting Ø 10x1 to Ø 6x1 incl M14x1 Fig. 1 O-ring Reducing fitting Ø 10x1 to Ø 8x1 incl M14x1 Fig. 1 O-ring Reducing fitting Ø 8x1 to Ø 6x1, pushin Fig. 2 incl. O-ring Reducing fitting Ø 8x1 to Ø 8x1, pushin Fig. 2 incl. O-ring fitting, for port R and S for 8x M14x1 Fig Tubing connector for fabric-reinforced 8 33 M12x1 Fig. 3 tubing Ø 8x3, incl. O-Ring elbow fitting Ø 10x1 to Ø 6x1, incl. 4 Fig. 4 O-ring elbow fitting Ø 10x1 to Ø 8x1, incl. 6 Fig. 4 O-ring elbow fitting Ø 10x1 to Ø 10x1, incl. 8 Fig. 4 O-ring Tube nut for silencer Fig Silencers Fig Screw plug, Ø 8x1 M12x1 Fig Screw plug, Ø 10x1 M14x1 Fig Adapter, Ø 8x1, G 1/4, incl. O-ring 27 M12x1 Fig. 10 Bosch Rexroth AG Pneumatics D893_900 13

14 Your contact: Canada Bosch Rexroth Canada Corp Mainway Drive Burlington, Ontario L7M 1A8 Tel Fax Australia Bosch Rexroth Pty. Ltd. 3 Valediction Road Kings Park NSW 2148 Sydney Tel Fax Bosch Rexroth AG Pneumatics Ulmer Straße 4 D Laatzen Phone Fax sales-pneumatics@boschrexroth.de U.S.A. Bosch Rexroth Corp Mercer Road Lexington, KY Kentucky Tel Fax Great Britain Bosch Rexroth Ltd. Broadway Lane South Cerney Cirencester, GL7 5UH Gloucestershire Tel Fax further contacts: The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging. This document, as well as the data, specifi cations and other informations set forth in it, are the exclusive property of Bosch Rexroth AG. Without their consent it may not be reproduced or given to third parties. Subject to modifi cations. Online-PDF

Directional valves Mechanically operated Series AP. Brochure

Directional valves Mechanically operated Series AP. Brochure Series AP InduParts Pneumatics B.V.B.A. Sint-Jorisstraat 40 B-8800 ROESELARE BELGIUM Tel. +31 (0)51 22 58 88 Fax. +31 (0)51 22 58 98 info@induparts.com www.induparts.com Brochure Bosch Rexroth AG Pneumatics

More information

Directional valves Mechanically operated Series CD07. Brochure

Directional valves Mechanically operated Series CD07. Brochure Series CD07 InduParts Pneumatics B.V.B.A. Sint-Jorisstraat 40 B-8800 ROESELARE BELGIUM Tel. + (0)5 58 88 Fax. + (0)5 58 98 info@induparts.com www.induparts.com Brochure Bosch Rexroth AG Pneumatics Series

More information

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure Bellow actuator with mounting ring, series BCR Brochure 2 Bosch Rexroth AG Pneumatics Bellow actuator with mounting ring, series BCR Bellow actuator, BCR single Stroke: 94-135 mm 3 double Stroke: 185-233

More information

Pneumatic connection technologies Rotary joints Rotary joints. Brochure

Pneumatic connection technologies Rotary joints Rotary joints. Brochure Pneumatic connection technologies s s Brochure Bosch Rexroth AG Pneumatics Pneumatic connection technologies s s number of controlled lines: 2 3 4 6 8 Fett markierte Materialnummern sind ab Zentrallager

More information

Cylinder accessories Shock absorbers SA2 series. Brochure

Cylinder accessories Shock absorbers SA2 series. Brochure SA2 series Brochure 2 Bosch Rexroth AG Pneumatics SA2 series Industrial shock absorber, Series SA2-MS for MSC cushioning: self-compensating sealing for piston rod: Lip ring Mounting thread: M6x0,5 - M14x1,5

More information

Directional valves Electrically operated CL03 series-ev. Brochure

Directional valves Electrically operated CL03 series-ev. Brochure CL03 series-ev Brochure 2 Rexroth Pneumatics CL03 series-ev Qn = 700 l/min valve width: 16 mm NO/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 3 Qn = 700 l/min

More information

Valve terminal systems Valve terminal systems Series TC08. Brochure

Valve terminal systems Valve terminal systems Series TC08. Brochure Series TC08 Brochure Bosch Rexroth AG Pneumatics Series TC08 Valve terminal systems Valve terminal system, Series TC08 Qn max. = 800 l/min; single plug-in wiring; Electr. connection: Plug M8 / plug, form

More information

Valve terminal systems Valve terminal systems Series TC15. Brochure

Valve terminal systems Valve terminal systems Series TC15. Brochure Series TC15 Brochure Bosch Rexroth AG Pneumatics Series TC15 Valve terminal systems Valve terminal system, Series TC15 Qn max. = 1500 l/min; single plug-in wiring; Electr. connection: plug, form C / Plug

More information

Rotary actuators Rack-and-pinion gears series TRR. Brochure

Rotary actuators Rack-and-pinion gears series TRR. Brochure series TRR Brochure 2 Bosch Rexroth AG Pneumatics series TRR Rotary cylinder, Series TRR angle of rotation: 0-60 Ø2-00 mm with magnetic piston double piston with rack cushioning: pneumatically, adjustable

More information

SCU Stretching Cylinder Units for PET Blow Molding Machines

SCU Stretching Cylinder Units for PET Blow Molding Machines Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service SCU Stretching Units for PET Blow Molding Machines Pneumatic solutions from Rexroth 2 Machine-specific

More information

Flow and check valves Logic valves Logic valves (AND/OR) Brochure

Flow and check valves Logic valves Logic valves (AND/OR) Brochure Flow and check valves Logic valves Brochure 2 Flow and check valves Logic valves Shuttle valve (OR) Qn = 80 l/min Plate valve with pipe connection Compressed air connection input: Ø 4 compressed air connection

More information

5/2 Valve Series 585, G 1/8-G 1/4

5/2 Valve Series 585, G 1/8-G 1/4 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service 5/2 Valve Series 585, G 1/8-G 1/4 Technical data 5/2 Valve Series 585, G 1/8-G 1/4 Single valve, single

More information

The New Generation ISO Cylinders for a Dynamic Future

The New Generation ISO Cylinders for a Dynamic Future Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service The New Generation ISO Cylinders for a Dynamic Future Rexroth s new generation of ISO pneumatic cylinders

More information

Highly Varied and Energy Efficient The CVI Series of Cylinder Valve Units from Rexroth

Highly Varied and Energy Efficient The CVI Series of Cylinder Valve Units from Rexroth Highly Varied and Energy Efficient The CVI Series of Cylinder Valve Units from Rexroth 2 Cylinder valve units, CVI series Configurator Individual solutions made easy create working units at the click of

More information

Electric Drives. Linear Motion and Assembly Technologies Pneumatics Service. Valves, Series VP15. Technical data

Electric Drives. Linear Motion and Assembly Technologies Pneumatics Service. Valves, Series VP15. Technical data Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Valves, Series VP5 Technical data Completely mounted valve terminal system, BUSdirect (Profibus DP) Technical

More information

3/2 Dovetail Valves, ND 2, G 1/8

3/2 Dovetail Valves, ND 2, G 1/8 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Service 3/2 Dovetail Valves, ND 2, G /8 Technical data 3/2 Dovetail Valves, ND 2, G /8 Normally closed or open Technical Data

More information

Берг АБ Тел. (495) , факс (495) ITS Series Pneumatic Cylinders Extreme Resilience and Power

Берг АБ Тел. (495) , факс (495) ITS Series Pneumatic Cylinders Extreme Resilience and Power ITS Series Pneumatic Cylinders Extreme Resilience and Power 2 ITS Series Pneumatic Cylinders Applications Tough cylinders for real forces! Compressed air packs a punch, a powerful one: managing extreme

More information

Pressure regulators E/P pressure regulators Series EV07. Brochure

Pressure regulators E/P pressure regulators Series EV07. Brochure Pressure regulators E/P pressure regulators Series EV07 Brochure 2 Pressure regulators E/P pressure regulators Series EV07 Qn= 800 l/min Compressed air connection output: G 1/4 Electr. connection: Plug,

More information

Directional valves Mechanically operated Series AP - inch. Brochure

Directional valves Mechanically operated Series AP - inch. Brochure Directional valves Mechanically operated Brochure 2 Directional valves Mechanically operated Qn= 150-250 l/min pipe connection compressed air connection output: 1/8-27 NPTF 3 Actuating controls for AP/ST

More information

Directional valves Pneumatically operated, according to standard ISO , 18 mm, CD02-AL series. Brochure

Directional valves Pneumatically operated, according to standard ISO , 18 mm, CD02-AL series. Brochure Directional valves Pneumatically operated, according to standard Brochure 2 Directional valves Pneumatically operated, according to standard 5/2-directional valve, Series CD02-AL Qn = 450 l/min plate connection

More information

Pressure regulators E/P pressure regulators Series EV04. Brochure

Pressure regulators E/P pressure regulators Series EV04. Brochure Pressure regulators E/P pressure regulators Brochure Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN

More information

Pressure regulators E/P pressure regulators Series ED02. Brochure

Pressure regulators E/P pressure regulators Series ED02. Brochure Pressure regulators E/P pressure regulators Series ED0 Brochure Pressure regulators E/P pressure regulators Series ED0 E/P pressure regulator, Series ED0 Qn= 10 l/min compressed air connection output:

More information

Rodless cylinders Rodless cylinders Series RTC. Brochure

Rodless cylinders Rodless cylinders Series RTC. Brochure Series RTC Brochure Bosch Rexroth AG Pneumatics Series RTC Rodless cylinder, Series RTC-BV Ø 16-80 mm; double-acting; with magnetic piston; integrated guide; Basic Version; cushioning: pneumatic, adjustable

More information

5/2-way valve, Series ST Qn= 280 l/min pipe connection compressed air connection output: G 1/8 with spring return

5/2-way valve, Series ST Qn= 280 l/min pipe connection compressed air connection output: G 1/8 with spring return 00108065 Version Spool valve not lockable Sealing principle metal/metal sealing Working pressure min./max. -0.95 bar / 10 bar Ambient temperature min./max. -15 C / +80 C Medium temperature min./max. -15

More information

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217 1 00137795 Version Spool valve, zero overlap Sealing principle Soft sealing Mounting on manifold strip P-strip Working pressure min./max. See table below Control pressure See table below min./max. Ambient

More information

Pressure regulators E/P pressure regulators Series ED05. Brochure

Pressure regulators E/P pressure regulators Series ED05. Brochure Series ED05 Brochure Series ED05 Qn= 000 l/min Compressed air connection output: G /4 Electr. connection: via signal connection Signal connection: input and output, Plug, M, 5-pin 4 Qn= 000 l/min Compressed

More information

Flow and check valves Logic valves Pneumatic counters. Brochure

Flow and check valves Logic valves Pneumatic counters. Brochure Flow and check valves Logic valves Pneumatic counters Brochure 2 Flow and check valves Logic valves Pneumatic counters Pneumatic presetting counter (add) 5-digit, digits Compressed air connection input:

More information

E/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin

E/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Version Poppet valve Control

More information

Preparation of compressed air Supplementary products Pressure gauge. Brochure

Preparation of compressed air Supplementary products Pressure gauge. Brochure Preparation of compressed air Pressure gauge Brochure 2 Preparation of compressed air Pressure gauge Pressure gauge, Series P1-SNL Front port Background color: Scale color: reen / White Viewing window:

More information

Max. particle size 50 µm

Max. particle size 50 µm 00123883 Version Poppet ale Control Analog Certificates CE declaration of conformity Ambient temperature min./max. +0 C / +50 C Medium temperature min./max. +0 C / +50 C Medium Compressed air Max. particle

More information

Cylinder Accessories Piston rod mountings, series CM2 Rod clevises. Brochure

Cylinder Accessories Piston rod mountings, series CM2 Rod clevises. Brochure Cylinder Accessories Piston rod mountings, series 2 Rod clevises Brochure 2 Cylinder Accessories Piston rod mountings, series 2 Rod clevises Rod clevis with lock washer, Series AP2 Stainless steel 3 Rod

More information

Number of fingers 2. Max. particle size 5 µm. Pressure for determining forces

Number of fingers 2. Max. particle size 5 µm. Pressure for determining forces Bosch Rexroth AG Pneumatics Version Parallel Number of fingers 2 Grip tolerance 0,02 mm Lubrication gripping elements Lubricated for life 00117208 Ambient temperature min./max. +5 C / +60 C Medium Compressed

More information

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer Type Ejector Ambient temperature min./max. +0 C / + C Medium temperature min./max. +0 C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed

More information

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR Brochure 2 Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR single Stroke: 94-135 mm 3 double

More information

Max. particle size 50 µm Max. oil content of compressed air

Max. particle size 50 µm Max. oil content of compressed air 1 Version Poppet valve Control Analog Certificates CE declaration of conformity Ambient temperature min./max. +0 C / +70 C Medium temperature min./max. +0 C / +70 C Medium Compressed air Max. particle

More information

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer Type Ejector Ambient temperature min./max. + C / + C Medium temperature min./max. + C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed

More information

Sensor technologies Pressure sensors Series PE5. Brochure

Sensor technologies Pressure sensors Series PE5. Brochure Sensor technologies Pressure sensors Series PE5 Brochure 2 Sensor technologies Pressure sensors Series PE5 Operating pressure: -4.5-74 electronic Output signal digital: 2 outputs - output IO-Link electr.

More information

Cylinder Accessories Handling connection kits Easy2Combine. Brochure

Cylinder Accessories Handling connection kits Easy2Combine. Brochure Cylinder Accessories Handling connection kits Easy2Combine Brochure 2 Cylinder Accessories Handling connection kits Easy2Combine For combination: RTC-HD / RTC-CG 4 For combination: MSC / RCM 7 For combination:

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters 6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports

More information

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

6/2 ways/positions flow diverters L (VS151-VS152-VS155) 6/2 ways/positions flow diverters L721... (VS151-VS152-VS155) RE 1832-5 Edition: 2.216 Replaces: 5.214 Size 6 Series 1 Maximum operating pressure 31 bar (45 psi) Maximum flow 6 l/min (15.85 gpm) Ports

More information

Sensor technologies Proximity sensors Sensor mountings. Brochure

Sensor technologies Proximity sensors Sensor mountings. Brochure Sensor mountings Brochure 2 Sensor mountings for Series ST6, SM6 to mount on cylinder MNI, ICM 4 for Series ST6 to mount on cylinder CSL-RD, ICM, ICS-D1, ICS-D2, RPC 5 for Series ST6 to mount on cylinder

More information

Max. oil content of compressed air

Max. oil content of compressed air 1 Version Control Certificates Ambient temperature min./max. Medium temperature min./max. Medium Poppet valve Analog CE declaration of conformity +32 F / +15 F +32 F / +15 F Compressed air 0012533 Max.

More information

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

6/2 ways/positions flow diverters L (VS120-VS125-VS129) 6/2 ways/positions flow diverters L710... VS120-VS125-VS129) RE 18302-04 Edition: 05.2014 Replaces: 07.12 Size 4 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 25 l/min 6.6 gpm) Ports

More information

Series PRA and TRB ISO Pneumatic Cylinders from Rexroth

Series PRA and TRB ISO Pneumatic Cylinders from Rexroth Series PRA and TRB ISO 15552 Pneumatic Cylinders from Rexroth The next generation of ISO pneumatic cylinders Series PRA and TRB Pneumatic ISO 15552 Cylinders The next generation of ISO cylinders from Rexroth

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/07.12 Replaces: 12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F) Size 10 Series 00 Maximum operating pressure 310 bar [4500

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 18302-07/12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00

More information

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6 Check valve RE 2536/07.05 Replaces: 05.02 /6 ype ZS Size0 Component series 3X Maximum operating pressure 35 bar Maximum flow 00 l/min H5856 able of contents Contents Page Features Ordering code 2 Standard

More information

Nominal sizes 08 to 10, special cavities

Nominal sizes 08 to 10, special cavities Nominal sizes 08 to 10, special cavities RE 18301-91 Edition: 05.2016 Replaces: 07.2012 Contents Relief, direct acting guided poppet type Common cavity, Size 10 2 Relief, direct acting guided poppet type

More information

Standards ISO Max. particle size 50 µm. Pressure for determining piston forces 6 bar. Materials:

Standards ISO Max. particle size 50 µm. Pressure for determining piston forces 6 bar. Materials: Bosch Rexroth AG Pneumatics Ø - 100 mm Ports: M5 - double-acting with magnetic piston cushioning: elastic piston rod: Standards ISO 21287 Compressed air connection internal thread 00119673 Working pressure

More information

6 to 12/2 ways/positions bankable flow diverters flangeable

6 to 12/2 ways/positions bankable flow diverters flangeable 6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/07.12 Replaces: 12.09 1/8 L711... (VS120F-VS125F) Size 4 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 20

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 1832-5/12.9 1/8 L721... (VS151-VS152-VS155) Size 6 Series 1 Maximum

More information

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

3/2 ways/positions flow diverters L (VS91-VS92-VS95) 3/2 ways/positions flow diverters L706... (VS91-VS92-VS95) RE 18302-03 Edition: 04.2016 Replaces: 02.2016 Size 12 Series 00 Maximum operating pressure 310 bar (4500 psi) Maximum flow 140 l/min (36.98 gpm)

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4

CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4 CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4 42 AVENTICS The Ceramic Advantage Tough enough to survive, no matter where in the world you send it The secret s a ceramic seal. Inside the

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F)

More information

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections 4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RE 183-52/7.12 Replaces: 1.9 1/8 8_8 (EDZ) Size 4 Series Maximum operating pressure 31 bar

More information

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A)

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A) 4/3-4/2 Directional valve elements B8_A with or without (EDB-A) secondary relief valves, with or without LS connections B8_A (EDB-A) RE 183-56 Edition: 11.218 Replaces: 7.12 Size 4 Series Maximum operating

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-09/12.09 1/10 L732... (VS241F-VS245F-VS246F-VS247F)

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 685/.5 Replaces:. /6 Type DR K Size Component series X Maximum operating pressure 5 bar Maximum flow l/min K478/7 Table of contents Contents Page Features Ordering

More information

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL Breather filter RE 44/0.09 Replaces: 08.08 /6 Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL Nominal size: BF 7 SL 4/, 90, 0; BS 7 SL 4/, 90, 0; BE 7 SL 4/; B 7 SL 4/ Connections up to DN Operating temperature

More information

Supply pressure compensator, direct operated

Supply pressure compensator, direct operated Supply pressure compensator, direct operated RE 2923/09. /6 Type ZDC Size 6 Component series X Maximum operating pressure 250 bar Maximum flow 35 l/min H7870 Table of contents Contents Page Features Ordering

More information

Cylinder Accessories Cylinder mountings; series CM1 Trunnion mountings. Brochure

Cylinder Accessories Cylinder mountings; series CM1 Trunnion mountings. Brochure Cylinder Accessories Cylinder mountings; series CM1 Trunnion mountings Brochure 2 Cylinder Accessories Cylinder mountings; series CM1 Trunnion mountings Center trunnion mounting, Series MT4 for Series

More information

4/3 Proportional directional valve elements L85P5 with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING

4/3 Proportional directional valve elements L85P5 with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING / Proportional directional valve elements L8P with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING L8P (EDC-IP) RE 8- Edition:.6 Replaces: 7. Size 6 Series

More information

Throttle and throttle check valve

Throttle and throttle check valve Throttle and throttle check valve RE 79/0.09 Replaces: 0.06 /6 Types MG and MK Size 6 to 0 Component series X Maximum operating pressure 5 bar Maximum flow 400 l/min K564- Table of contents Contents Page

More information

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC) Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC) Model 4WRP..E.. /..W..

More information

Filter-cooler circulation circuit with in-line filter according to DIN 24550

Filter-cooler circulation circuit with in-line filter according to DIN 24550 Filter-cooler circulation circuit with in-line filter according to DIN 0 RE 01/0.0 1/10 Type ABUKG Component series 1X with: circulation pump type PGF or type PVV el. motor, frame sizes 0 to 13 low-pressure

More information

6 to 12/2 ways/positions bankable flow diverters flangeable

6 to 12/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/12.09 1/10 L711... (VS120F-VS125F)

More information

Profile cylinders Euromec, Series 168

Profile cylinders Euromec, Series 168 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Profile cylinders Euromec, Series 68 Technical data Profile cylinders Euromec, Series 68 Double-acting,

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 6 DP Nominal size 6 Series 5X Maximum operating pressure 315 bar (4600 PSI) Maximum flow 60 L/min

More information

ES05 THE ESSENTIAL valve SYSTEM

ES05 THE ESSENTIAL valve SYSTEM ES05 THE ESSENTIAL valve SYSTEM simple, flexible and efficient 41 AVENTICS ES05 Valve System ES05 the simple solution for elementary pneumatics from your idea to the finished product: The ES05 Essential

More information

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces: Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating

More information

3/2 ways/positions flow diverters

3/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 3/2 ways/positions flow diverters RE 18302-02/12.09 1/8 L705... (VS81-VS82-VS84-VS85) Size 6 Series 00

More information

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC Supply pressure compensator, direct operated ype ZDC Size 6 Component series X Maximum operating pressure 50 bar Maximum flow 35 l/min able of contents Contents Page Features Ordering code Function, section

More information

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RA 183-52/1.11 1/1 4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections B8_8 (EDBZ) Summary Description Page General specifications 1 Ordering

More information

Universal Through Drive

Universal Through Drive Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Universal Through Drive RE 95 581/12.05 1/8 Replaces: IP029 MH059 Technical Data Sheet For the variable

More information

The Short-Stroke Cylinder Standardized according to ISO 15524: The SSI Series, Small and Smooth

The Short-Stroke Cylinder Standardized according to ISO 15524: The SSI Series, Small and Smooth The Short-Stroke Cylinder Standardized according to ISO 15524: The SSI Series, Small and Smooth 2 SSI series pneumatic cylinders Properties Top quality on a standard basis ISO cylinder series SSI Compatibility

More information

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated Model 4 WRA(E)B Size 6 Series 1X

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2018 Replaces: 03.2016 Technical data Description

More information

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z) 4/3-4/2 Directional valve elements LF1_1 LC1F-Z) RE 18305-01 Edition: 02.2016 Replaces: 07.12 07.2012 Size 6 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 35 l/min 9.25 gpm) Ports

More information

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 426-548 www.cmafh.com Proportional pressure reducing valve, pilot operated Type DRE and ZDRE Size 6 Component

More information

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow A-VRFC3C-VEI-VS-LS 0M.43.21.80 - Y - Z RE 18309-63 Edition: 03.2018 Replaces: 03.2016 Technical

More information

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09 Pressure relief valve, direct operated ype ZDBY D, ZDBY D RE 5 Edition: -8 Replaces:.9 Size 6 Component series X Maximum operating pressure 35 bar Maximum flow 6 l/min tb3 Features Contents Sandwich plate

More information

Insert Valves Flow control

Insert Valves Flow control RE 90010-05/07.2012 Bosch Rexroth Oil Control S.p.A. Insert Valves Flow control Designation Description Cavity Code Data sheet Pages Insert valve flow control, 2-way pressure compensated partially adjustable

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Servo solenoid valves with on-board electronics (OBE) RA 29045/01.05 1/12 Model 5WRPE 10 Size 10 Unit

More information

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL Specifications and features 4 Way / 2 & 3 Position Solenoid & Air Pilot Operated Diaphragm-Poppet Valve TECHNICAL DATA: Port Sizes: Integrated Fittings for

More information

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING / and / Proportional directional valve elements L88 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING L88 (EDC-P) RE 181-9 Edition:.16 Replaces: 7.1 7.1 Size 6 Series Maximum operating pressure

More information

Stand alone 4/3, 4/2 solenoid operated directional valve

Stand alone 4/3, 4/2 solenoid operated directional valve Stand alone 4/3, 4/2 solenoid operated directional valve (LF ) FAN DRIVE (LF ) RE 1835-4 Edition: 2.216 Replaces: 7.12 7.212 LF1 Size 6 LF2 Size 1 Series LF1 Maximum operating pressure 31 (45 ) LF2 Maximum

More information

CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4

CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4 CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4 2 The Ceramic Advantage AVENTICS Ceram 4-way Pneumatic Directional Control Valve Tough enough to survive, no matter where in the world you

More information

Axial Piston Variable Pump A2VK

Axial Piston Variable Pump A2VK Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump A2VK RE 94001/06.10 1/12 Replaces: 07.04 Data sheet Size 12 to 107 Series 1

More information

LUDV control block in mono block/sandwich plate design M7-20

LUDV control block in mono block/sandwich plate design M7-20 LUDV control block in mono block/sandwich plate design M7-20 RE 64293 Edition: 06.2013 Replaces:. Size 20 Series 3X Maximum operating pressure On the pump side 380 bar On the actuator side 420 bar Maximum

More information

Check valve, pilot operated

Check valve, pilot operated Check valve, pilot operated RE 21460/07.05 Replaces: 06.02 1/8 Types SV and SL Size 6 Component series 6X Maximum operating pressure 315 bar Maximum flow 60 l/min H6090 Table of contents Contents Page

More information

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated Proportional cartridge throttle valve, with inductive position transducer, pilot operated RE 29215/09.05 1/18 Type FESX Nominal size 16, 25, 32, 40, 50 Unit series 1X Maximum working pressure A, B, X 315

More information

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company Electro-Pneumatic Devices Valves and Positioners The Drive & Control Company Electro-Pneumatic Devices Dynamic precision from Rexroth Why choose Rexroth E/P s? Rexroth electro-pneumatic pressure control

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2016 Replaces: 06.2010 Technical data Description

More information

Series 581 ISO Pneumatic Directional Control Valves

Series 581 ISO Pneumatic Directional Control Valves Series 581 ISO 5599-1 Pneumatic Directional Control Valves Series 581 Pneumatic Valves 01_1 st Headline_36 pt/14.4 mm 4-Way ISO Directional Control second line Series 581 - A complete series of standardized

More information

Max. particle size 5 µm. Pressure for determining piston forces Repetitive precision. Polyurethane

Max. particle size 5 µm. Pressure for determining piston forces Repetitive precision. Polyurethane Piston rod cylinders Guide cylinders 1 Ambient temperature min./max. +0 C / +60 C edium Compressed air ax. particle size 5 µm Oil content of compressed air 0 mg/m³ - 1 mg/m³ Pressure for determining piston

More information

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) RE 18305-03 Edition: 02.2016 Replaces: 07.12 07.2012 Size 10 Series 00 Maximum operating pressure 250 bar (3600 psi) Maximum flow 90

More information

THE SSI SERIES, SMALL AND SMOOTH THE SHORT-STROKE CYLINDER STANDARDIZED ACCORDING TO ISO 15524

THE SSI SERIES, SMALL AND SMOOTH THE SHORT-STROKE CYLINDER STANDARDIZED ACCORDING TO ISO 15524 THE SSI SERIES, SMALL AND SMOOTH THE SHORT-STROKE CYLINDER STANDARDIZED ACCORDING TO ISO 15524 2 SSI series pneumatic cylinders Properties Top quality on a standard basis ISO cylinder series SSI Compatibility

More information

Pipe burst safety valve

Pipe burst safety valve Pipe burst safety valve RE 6623/06.06 Replaces: 03.99 1/12 ype MHRB Nominal sizes 16 and 22 omponent series 3 Maximum operating pressure 350 bar Maximum flow NS 16 200 l/min NS 22 00 l/min H536 ype MHRB

More information

5-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow, for two pumps systems

5-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow, for two pumps systems 5-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow, for two pumps systems RE 18309-54/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC3C-VEI-VS 0M.43.12.80 - Y - Z

More information