1 FC Hydraulic Pumps T7 for variable speed drives Denison Vane Technology

2 Catalogue HY29-11/UK Content General Information Introduction and product key features 3 Main Technical Data Main table for single pumps 4 Main table for double pumps 5 Inlet pressure range 6 Outlet pressure range 7 Pump operating range 8-9 Control modes 1 Hydraulic fluids and seals 1 Ordering Codes and Dimension Drawings Technical Data Pumps T7A 11 T7A 12 T7AW 13 T7B 14 T7B 15 T7D 16 T7D 17 T7BB 18 T7BB 19 T7DB 2 T7DB 21 T7DD 22 T7DD 23 Porting diagrams for double pumps 24 Performance curves, maximum torque and loads on shaft T7A - T7A 25 T7AW 26 T7B - T7B 27 T7D - T7D 28 T7BB - T7BB 29 T7DB - T7DB 3 T7DD - T7DD 31 Pump election Pump selection example Time restriction principle 34 Time restriction tables Circuit Design Pressure holding 39 Decompression 4 Dynamic characteristics 4 Pump installation 41 tart-up instructions 42 Maintenance 42 Warning 43 2 Parker Hannifin Manufacturing France A

3 Catalogue HY29-11/UK Introduction Introduction T7 pumps for variable speed drives Parker Hannifin is proud to introduce in this catalogue its selection of hydraulic vane pumps especially dedicated to variable speed drive applications. The unique technology of theses hydraulic pumps is allowing a wide range of operating speeds, to take the maximum benefits of modern power transmissions. When driven with asynchronous or synchronous electric motors and piloted by frequency controllers, they operate in the most efficient and reliable ways, allowing maximum energy savings. Licensing for these images came with permission from the Parker Hannifin Media Manager collection. Main benefits of variable speed drives Energy savings Up to 7% less electric Energy for the E Motor and less or no cooling for the hydraulic equipement. Lower noise emissions. Lower total cost of the hydraulic system maller pump, less valves, less or no cooling, smaller fluid tank, increased lifetime for the components. Product key features Reliable performance These T7 hydraulic pumps have been designed especially for variable speed drives and are offering a wide speed range. Like all our T7 eries vane pumps, the performances do remain very stable over time, making these pumps an ideal solution for modern electro-hydraulically operated machines. Long lifetime The fully pressure balanced concept increases the pump lifetime over its full operating range while double lip vanes reduce the sensitivity to fluid pollution. Low noise The Denison Vane Technology allows very low noise levels over the entire operating range and during the whole life of the pump. Versatility and compactness With several displacements for the same installation size, the T7 are a very powerful and compact pumps. The various pumping units (cartridge kits) can also be combined with other pumping unit sizes in multiple pumps. This creates a wide range of multi flow pumps, very much adapted to the high power needs. 3 Parker Hannifin Manufacturing France A

4 Catalogue HY29-11/UK Main Technical Data ingle Pumps Type T7A T7A T7AW T7B T7B T7D T7D Theoretical Displacement Vi Maximum peed HF-, HF-1 HF-2 HF-4, HF-5 3) HF-, HF-2 Maximum Pressure HF-1, HF-4, HF-5 Ring size Int. Cont. Int. Cont. cm 3 /rev. rpm rpm bar bar bar bar E6 5,8 E1 9,8 E11 11, E13 12, E E2 19,8 E22 22,5 E25 24, E22 22, E26 26, 36 E28 28, E3 3, 31 E32 31, E34 34, 28 E36 36, E4 4, 23 E3 9,8 E4 12,8 E5 15,9 E6 19,8 E7 22, ) 29 E8 24,9 E9 28, E1 31,8 E11 35, 34 E12 41, E14 45, E15 5, 3 2) E14 44, E17 55, E2 66, E22 7,3 3 3 E24 81, E28 9, E31 99,2 E35 113,4 E38 12, E42 137, ) Please consult Parker for application over 3 bar. 2) 27 for pump with M ports. 3) with 1,2 m/s fluid velocity HF-, HF-2 = Antiwear Petroleum Base HF-4 = Water Glycols olutions HF-1 = Non Antiwear Petroleum Base HF-5 = ynthetic Fluids Note : For further information or if the performance characteristics outlined in the table do not meet your particular requirements, please consult your local Parker office. 4 Parker Hannifin Manufacturing France A

5 Catalogue HY29-11/UK Main Technical Data Maximum peed Maximum Pressure Double Pumps Theoretical Displacement HF-, HF-1 HF-4, HF-5 HF-, HF-2 HF-1, HF-4, HF-5 Vi 3) HF-2 Int. Cont. Int. Cont. Type Ring size cm 3 /rev. rpm rpm bar bar bar bar E3 9,8 E4 12,8 E5 15,9 E6 19,8 E7 22,5 E8 24, E9 28, E1 31,8 E11 35, E12 41, E14 45, E15 5, E14 44, E17 55, E2 66, E22 7,3 3 3 E24 81, E28 9, E31 99,2 E35 113,4 E38 12, E42 137, E14 44, E17 55, E2 66, E22 7,3 3 3 E24 81, E28 9, E31 99,2 E35 113,4 E38 12, E42 137, T7BB T7BB T7DB T7DB T7DB T7DB T7DD T7DD 3) with 1,2 m/s fluid velocity HF-, HF-2 = Antiwear Petroleum Base HF-1 = Non Antiwear Petroleum Base HF-4 = Water Glycols olutions HF-5 = ynthetic Fluids Note : For further information or if the performance characteristics outlined in the table do not meet your particular requirements, please consult your local Parker office. 5 Parker Hannifin Manufacturing France A

6 Catalogue HY29-11/UK Main Technical Data Inlet pressure range - Minimum inlet pressure : Read the minimum inlet pressure requirement in the below table, depending on the pump type, ring size and its maximum operating speed. Never go under,8 bar Absolute (11.6 psi Absolute). Cartridge peed rpm ize Ring E6 E1,8 E11,8 A E13,8,8,8,8,8,8,8,8,8,8,8,8 E17,88 A E2,94,88 E22 1, E25,85 E22 E26,82,85,92,98 AW E28,98,8,8,85,88 E3,8,8,8,8,8,8,8,8 E32,9 E34 E36 E4 E3 E4 E5,8,8,8,8 E6,82,85,92,98 E7 B,8,8,8,8 E8,8,8,8,8,8,8,85,88,98 1,5 E9 B E1,94 1,7 1,15 E11,9,96 1,15 E12 E14, ,84,84,92 E15 E14 E17,8,8 E2,82,86 E22,8,8,8,83,88 D E24,8,86,95,8,8,8,8,8 E28,88 1, D E31,9 1,5 E35,84,86,92,97 E38,86,86,94 1,1 E42,9 1, Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 1 and 65 ct. The difference between inlet pressure at the pump flange and atmospheric pressure must not exceed,2 bar to prevent aeration. Multiply absolute pressure by 1,25 for HF-4 fluid and by 1,35 for HF-5 fluid. For double pumps, take the value of the cartridge requiring the highest absolute pressure. - Maximum inlet pressure : Read the information on the product key sheet page. tandard shaft seals are limited to,7 bar (1 psig) but some allow 7 bar (1 psig). 6 Parker Hannifin Manufacturing France A

7 Catalogue HY29-11/UK Main Technical Data Outlet pressure range - Minimum outlet pressure : It is recommended to always keep at least 1,5 bar (22 psi) differential between inlet and outlet. - Maximum outlet pressure : Please read the charts in this catalogue for the Max continuous and the Max intermittent pressure ratings. Depending on the average pressure in cycle, either the continuous or the intermittent will be the limit. - Average pressure in cycle : These Pumps may be operated intermittently at pressures higher than the recommended continuous rating when the time weighted average of pressure is less than or equal to the continuous duty pressure rating. This intermittent pressure rating calculation is only valid when the other parameters : speed, fluid, viscosity and contamination level are respected. For total cycle time longer than 15 minutes, please consult your Parker representative. Pressure (bar) ,5 A verage Pressure Cycle Example :.T7B - E1 Duty cycle _ 4 min. at 32 bar 1 min. at 35 bar 5 min. at 16 bar (4 x 32) + (1 x 35) + (5 x 16) 1 = 211,5 bar 5 Time (minutes) 1 211,5 bar is lower than 29 bar allowed as continuous pressure for T7B - E1 with HF- fluid. How to read a pump operating range chart Intermittent operation zone (time restriction) Intermittent operation zone (intermittent pressure) Continuous operation zone peed [rpm) For double pumps, check the operating range of each pumping unit. Restrict the max. speed and max. pressure to the values indicated in the table page 5. 7 Parker Hannifin Manufacturing France A

8 Catalogue HY29-11/UK Main Technical Data T7A - T7A Operating Range E17 E13 E11 E1 E6 E25 E22 E2 HF-, HF-2 fluids peed [rpm) T7AW Operating Range E4 E36 E34 E32 HF-, HF-2 fluids E3 E28 E26 E peed [rpm) 8 Parker Hannifin Manufacturing France A

9 Catalogue HY29-11/UK Main Technical Data T7B - T7B Operating Range E15 E14 E12 E11 E1 HF-, HF-2 fluids E9 E8 E7 E6 5 E5 E4 25 E peed [rpm) T7D - T7D Operating Range E E E35 E31 E28 HF-, HF-2 fluids 1 E24 75 E22 E2 5 E17 25 E peed [rpm) 9 Parker Hannifin Manufacturing France A

10 Catalogue HY29-11/UK Main Technical Data Control modes Our fixed displacement pumps, when driven at variable speeds, may operate in hydraulic open loop circuits with various control modes. Flow control mode The pump flow is varied according to the speed command signal of the drive unit. The necessary pressure limitation is achieved by a pressure relief valve in a classic way. Pressure / Flow control mode The pump flow is varied according to the speed command signal of the drive unit which also offers the ability to switch in pressure control mode. This mode requires fast pressure sensors, a servomotor with high dynamics, as well as a fast drive unit. The necessary pressure limitation is achieved by the pump and motor unit that only deliver enough fluid to limit the pressure to the set value. A pressure relief valve remains necessary, but as a safety device only. This control mode may require a specific circuit design. Regenerative mode With a suitable hydraulic circuitry and when driven in its opposite rotation way, the pump may be used as a hydraulic motor, offering an energy recovery functionality. However, for this hydraulic motor function being limited, please consult your local Parker office. Hydraulic fluids Recommended fluids Petroleum base anti-wear, anti-rust and anti-oxydation fluids (covered by Parker Denison HF- and HF-2 specifications). Maximum catalogue ratings and performance data are based on operation with these fluids. Acceptable alternate fluids The use of fluids other than petroleum based antiwear R & O fluids requires the maximum ratings of the pumps to be reduced, when the minimum inlet pressures must be increased. Fluids viscosity The minimum Viscosity Index is 9. The kinematic viscosity range is as below. Over or under these values, please contact Parker. Max. (cold start, low speed & pressure) 2 ct Min. (full speed & pressure for HF-1, HF-4 & HF-5 fluids) 18 ct Max. (full speed & pressure) 18 ct Min. (full speed & pressure for HF- & HF-2 fluids) 1 ct Optimum (max. lifetime) 3 ct Fluids temperatures The usual limitating factor of temperature (low or high) comes from the obtained viscosity. The seals are sometimes the limit. Maximum fluid temperature (also depends on min. viscosity) Minimum fluid temperature (also depends on max. viscosity). C F C F HF-, HF-1, HF (+ 212) HF-, HF-1, HF-2, HF-5-18 (-.4) HF (+ 122) HF (+ 5) HF (+ 158) Filtration requirement The fluid must be cleaned before and during operation to maintain a contamination level of IO 19 / 17 / 14 or NA 1638 class 8 or better. No inlet strainer or inlet filter is allowed on the fixed displacement pumps for variable speed drives. Water contamination in the fluid The maximum acceptable content of water shall be limited to,1 % for mineral base fluids, and,5 %for synthetic fluids, crankcase oils, and biodegradable fluids. The eventual excess of water must be drained off the circuit. Types of seals NBR seals 1 : Use this seal type for standard applications : with mineral oil and fluid temperature less than + 9 C (+ 194 F). 1 seals temperature range : - 4 C to + 17 C (- 4 F to F). EPDM seals 4 : Use this seal type when recommended by the fluid manufacturer. 4 seals temperature range : - 54 C to C (- 65 F to + 25 F). FPM seals 5 : Use this seal type with some fire resistant fluids and/or fluid temperature higher than + 9 C (+194 F). 5 seal temperature range : - 29 C to + 24 C (- 2 F to + 4 F). 1 Parker Hannifin Manufacturing France A

11 Catalogue HY29-11/UK T7A - Ordering Code & Dimensions Model No. T7A - E17-2 R - A M T7A series - 8-A2-HW IO 2 bolts mounting flange Displacement Volumetric displacement (cm 3 /rev.) E6 = 5,8 E1 = 9,8 E11 = 11, E13 = 12,8 E17 = 17,2 E2 = 19,8 E22 = 22,5 E25 = 24,9 Type of shaft 2 = keyed IO R775 Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Modifications Ex : NOP = Not painted Ports 5 = BPP threads = 1.1/4 BPP P = 3/4 BPP eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard P P P P P = Pressure = uction ,5 44,5 8,5 95,3 78,1 38, (Threaded port connection) 68 (Threaded port connection) 28 KEY 6 x ,5 x ,4 MOUNTING TORQUE : 11 Nm 64 1,5 x45 haft Code 2 KEYED (IO R775) ,5 MAXI 11,2 P PREURE 3/4" BPP UCTION 1"1/4 BPP 11 Parker Hannifin Manufacturing France A

12 Catalogue HY29-11/UK T7A - Ordering Code & Dimensions Model No. T7A - E17-1 R - A M T7A series - AE A 2 bolts J744 mounting flange Displacement Volumetric displacement (cm 3 /rev.) E6 = 5,8 E1 = 9,8 E11 = 11, E13 = 12,8 E17 = 17,2 E2 = 19,8 E22 = 22,5 E25 = 24,9 Type of shaft 1 = keyed (non AE) 19,5 3 = splined 16/32 (AE B) 13 teeth 4 = splined 16/32 (AE A) 9 teeth Modifications Ex : NOP = Not painted Ports M6 = 4 bolts AE flanges J518 with Metric thread 6 = 4 bolts AE flanges J518 with UNC thread = 1.1/4 P = 3/4 eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise P P P P P = Pressure = uction ,5 44,4 7,4 95,3 78,1 38,2 6,4 KEY 4, 76 / 4, , , ,5 x ,4 64,8 x45 MOUNTING TORQUE : 11 Nm haft Code 1 KEYED (NON AE) ,5 21,12 MAXI 3/8"-16 UNC-2B x 19 DEEP - 4 HOLE - AE VERION M1 x 19 DEEP - 4 HOLE - METRIC VERION 39,4 7,4 6,4 3/8"-16 UNC-2B x 17 DEEP - 4 HOLE - AE VERION M1 x 19 DEEP - 4 HOLE - METRIC VERION 22,3 3,2 11,2 31,1 7,4 19,1 1,5 x45 47,6 P 58,7 15 1,5 x45 haft Code 3 AE-B INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 13 TEETH - 3 PREURE ANGLE PREURE 19,5 UCTION 31,75 haft Code 4 AE-A INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 9 TEETH - 3 PREURE ANGLE 12 Parker Hannifin Manufacturing France A

13 Catalogue HY29-11/UK T7AW - Ordering Code & Dimensions Model No. T7AW - E32-1 R - A M T7AW series - AE A 2 bolts J744 mounting flange Displacement Volumetric displacement (cm 3 /rev.) E22 = 22, E26 = 26, E28 = 28, E3 = 3, E32 = 31,8 E34 = 34, E36 = 36, E4 = 4, Type of shaft 1 = keyed (non AE) 19,5 3 = splined 16/32 (AE B) 13 teeth X = splined 16/32 (AE A) 9 teeth Modifications Ex : NOP = Not painted Ports M = 4 bolts AE flanges J518 with Metric threads = 4 bolts AE flanges J518 with UNC threads = 1.1/4 P = 3/4 eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise P P P = Pressure = uction P 1 16,8 44, ,3 99,7 38,2 7,4 6,4 KEY 4,76 / 4, ,4 1,5 x , ,4 31,4 7,4 6,4 16 MOUNTING TORQUE : 11 Nm 3/8"-16 UNC-2B x 17 DEEP - 4 HOLE - AE VERION M1 x 19 DEEP - 4 HOLE - METRIC VERION 74,6 7/16"-14 UNC-2B x 22 DEEP - 4 HOLE - AE VERION M1 x 19 DEEP - 4 HOLE - METRIC VERION 22,3 3,2,8 x45 11,2 4 7,4 24,5 19, ,12 MAXI haft code 1 (KEYED NO AE) 47,6 P 58,7 1,5 x 3 1,5 x45 haft Code X AE-A INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 9 TEETH - 3 PREURE ANGLE PREURE 19,5 UCTION 31,8 haft Code 3 AE-B INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 13 TEETH - 3 PREURE ANGLE 13 Parker Hannifin Manufacturing France A

14 Catalogue HY29-11/UK T7B - Ordering Code & Dimensions Model No. T7B - E1-2 R - A 1 - M - M T7B series - 1 A2 HW IO 2 bolts mounting flange Displacement Volumetric displacement (cm 3 rev.) E3 = 9,8 E9 = 28, E4 = 12,8 E1 = 31,8 E5 = 15,9 E11 = 35, E6 = 19,8 E12 = 41, E7 = 22,5 E14 = 45, E8 = 24,9 E15 = 5, Type of shaft 2 = keyed (IO R775) Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Modifications Ex : NOP = Not painted Ports MW = = pecific flange pattern P = 1 - AE flange J518 with Metric threads M = 4 bolts AE flanges J518 with Metric threads = 1.1/2 P = 1 eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM -,7 bar max. (for fire resistant fluids) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard P P P P P = Pressure = uction 7 174, ,5 82,3 38,1 7 6,35 MAXI KEY 8 x 7 (h11) 76, , , ,5 x 45 73,7 147,4 MOUNTING TORQUE : 187 Nm 12,6 2x ±.7 28 MAXI M12 x 22.4 DEEP - 4 HOLE M1 x 19 DEEP - 4 HOLE 2.1/2" inlet flange O ring M8 x 16 deep-4 holes MW 45, M 35,8 26,2 12,7 1 78, 7 52,3 P HAFT CODE 2 (KEYED IO R775) UCTION 48 UCTION 38.1 PREURE Parker Hannifin Manufacturing France A

15 Catalogue HY29-11/UK T7B - Ordering Code & Dimensions Model No. T7B - E1-1 R - A 1 - M - M T7B series - AE B 2 bolts J744 mounting flange Displacement Volumetric displacement (cm 3 rev.) E3 = 9,8 E9 = 28, E4 = 12,8 E1 = 31,8 E5 = 15,9 E11 = 35, E6 = 19,8 E12 = 41, E7 = 22,5 E14 = 45, E8 = 24,9 E15 = 5, Type of shaft 1 = keyed (AE B) 3 = splined 16/32 (AE B) 13 teeth 4 = splined 16/32 (AE BB) 15 teeth Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Modifications Ex : NOP = Not painted Ports MW = = pecific flange pattern P = 1 - AE flange J518 with Metric threads M = 4 bolts AE flange J518 with Metric threads = 4 bolts AE flange J518 with UNC threads = 1.1/2" P = 1" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM -,7 bar max. (for fire resistant fluids) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard P P P P P = Pressure = uction 174,5 45,4 7,9 6,35 MAXI ,5 82,3 38,1 71,6 7,9 6,35 MAXI 24,5 76,2 38,1 KEY 6,35 / 6,3 14,3 147,4 51,3 11, ,5 x45 73,7 1,5 x 45 HAFT CODE 4 AE BB INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 15 TEETH - 3 PREURE ANGLE 147,4 MOUNTING TORQUE : 187 Nm 12,6 9,7 1,3 x 45 22, ,94 MAXI HAFT CODE 1 (KEYED AE B) 1/2-13 UNC x 22,4 DEEP - 4 HOLE M12 x 22,4 DEEP - METRIC VERION 3/8-16 UNC x 19 DEEP - 4 HOLE M1 x 19 DEEP - METRIC VERION 2.1/2" inlet flange O ring M8 x 16 deep-4 holes MW 45, M 35,8 26,2 12,7 4,7 7,9 6,35 MAXI 24,5 1,5 x 45 78, 7 52,3 P UCTION 48 UCTION 38,1 PREURE 25,4 HAFT CODE 3 AE B INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 13 TEETH - 3 PREURE ANGLE 15 Parker Hannifin Manufacturing France A

16 Catalogue HY29-11/UK T7D - Ordering Code & Dimensions Model No T7D - E42-5 R - A 1 - MW - M T7D series A2 HW IO 2 bolts mounting flange Displacement Volumetric displacement (cm 3 /rev.) E14 = 44, E28 = 9, E17 = 55, E31 = 99,2 E2 = 66, E35 = 113,4 E22 = 7,3 E38 = 12,6 E24 = 81,1 E42 = 137,5 Type of shaft 5 = keyed (IO G32M) Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Modifications Ex : NOP = Not painted Ports MW = 4 bolts AE flange J518 with Metric threads = 2.1/2" P = 1.1/4" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM - 7 bar max. (for fire resistant fluids) 5 = 5 VITON - 7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard P P P P P = Pressure = uction 212, ,4 38,1 87,4 7,9 6,35 MAXI 9,6 82,6 KEY 1 x 8 (h11) M1 x 2 DEEP 5 173,1 64, ,63 73, ,5 2,3 x ,18 +,2 35,3 MAXI 2x ,5 MOUNTING TORQUE : 187 Nm 9,5 9,5 HAFT CODE 5 (KEYED IO R775 G32M) M12 x 24-4 HOLE M12 x HOLE 15,7 5,8 3,2 88,9 58,7 P UCTION 63,5 PREURE 31,8 16 Parker Hannifin Manufacturing France A

17 Catalogue HY29-11/UK T7D - Ordering Code & Dimensions Model No T7D - E42-1 R - A 1 - W - M T7D series - AE C 2 bolts J744 mounting flange Displacement Volumetric displacement (cm 3 /rev.) E14 = 44, E28 = 9, E17 = 55, E31 = 99,2 E2 = 66, E35 = 113,4 E22 = 7,3 E38 = 12,6 E24 = 81,1 E42 = 137,5 Type of shaft 1 = keyed (AE C) 31,7 3 = splined 12/24 (AE C) 14 teeth Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Modifications Ex : NOP = Not painted Ports MW = 4 bolts AE flange J518 with Metric threads W = 4 bolts AE flange J518 with UNC threads = 2.1/2" P = 1.1/4" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM - 7 bar max. (for fire resistant fluids) 5 = 5 VITON - 7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination = standard P P P P P = Pressure = uction 9,5 212, ,4 38,1 83,6 7,9 6,35 MAXI 9,6 82,6 KEY 7,94 / 7,89 M1 x 2 DEEP 49,3 173,1 64, ,5 73,75 17,5 82,5 1,3 x 45 1,5 x 45 31,75 -,5 35,3 MAXI 147,5 MOUNTING TORQUE : 187 Nm 9,5 12,7 HAFT CODE 1 (KEYED AE C) 1/2-13 UNC x 23,9 DEEP - 4 HOLE M12 x 23,9 DEEP - METRIC VERION 7/16-14 UNC x 22,3 DEEP - 4 HOLE M12 x 22,3 DEEP - METRIC VERION 15,7 55,2 5,8 3,2 7,9 6,35 MAXI 38 2,3 x 45 88,9 58,7 P UCTION 63,5 PREURE 31,8 HAFT CODE 3 AE C INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 12/24 14 TEETH - 3 PREURE ANGLE 17 Parker Hannifin Manufacturing France A

18 Catalogue HY29-11/UK T7BB - Ordering Code & Dimensions Model No. T7BB - E1 - E1-5 R - A 1 - MW - M T7BB series - 1 A2 HW IO 2 bolts mounting flange Displacement P1 & Volumetric displacement (cm 3 /rev.) E3 = 9,8 E9 = 28, E4 = 12,8 E1 = 31,8 E5 = 15,9 E11 = 35, E6 = 19,8 E12 = 41, E7 = 22,5 E14 = 45, E8 = 24,9 E15 = 5, Type of shaft 5 = keyed (IO R775) P1 Modifications Ex : NOP = Not painted Ports MW = 4 bolts AE flange J518 with Metric threads = 2.1/2" P1 = 1" = 1" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM -,7 bar max. (for fire resistant fluids) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Design letter Porting combination (see page 24) = standard 174,5 262, ,6 11,6 38, ,4 MAXI KEY 8 x 7 (h11) M8 x 16 DEEP 14 84,1 75,5 76,2 51,3 1 -,33 1,5 x ,1 9 2 x ±,7 28 MAXI MOUNTING TORQUE : 61 Nm MOUNTING TORQUE : 187 Nm HAFT CODE 5 (KEYED IO R775) M1 x 19 DEEP - 4 HOLE M12 x 22,4 DEEP - 4 HOLE M1 x 19 DEEP - 4 HOLE 26,2 5,8 26,2 12,7 52,4 88,9 52,3 P1 PREURE 25,4 UCTION 63,5 PREURE Parker Hannifin Manufacturing France A

19 Catalogue HY29-11/UK T7BB - Ordering Code & Dimensions Model No. T7BB - E1 - E1-2 R - A 1 - MW - M T7BB series - AE B 2 bolts J744 mounting flange P1 Modifications Ex : NOP = Not painted Displacement P1 & Volumetric displacement (cm 3 /rev.) E3 = 9,8 E9 = 28, E4 = 12,8 E1 = 31,8 E5 = 15,9 E11 = 35, E6 = 19,8 E12 = 41, E7 = 22,5 E14 = 45, E8 = 24,9 E15 = 5, Type of shaft 2 = keyed (AE BB) 3 = splined 12/24 (AE B) 13 teeth Ports MW = 4 bolts AE flange J518 with Metric threads W = 4 bolts AE flange J518 with UNC threads = 2.1/2" P1 = 1" = 1" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM -,7 bar max. (for fire resistant fluids) 5 = 5 VITON -,7 bar max. (for mineral oil and fire resistant fluids) Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise Design letter Porting combination (see page 24) = standard 262,4 71, , ,6 11,6 38,1 6,4 MAXI 9,7 7,9 38,1 KEY 6,35 / 6,3 M8 x 16 DEEP 14,3 84,1 75,5 76,2 51, ,6 -,5 1,5 x 45 MOUNTING TORQUE : 61 Nm MOUNTING TORQUE : 187 Nm 116,1 1,3 x 45 HAFT CODE 2 (KEYED AE BB) 25,4 -,3 28,22 MAXI 4,7 7,9 6,4 MAXI 3/8-16 UNC x 19, DEEP - 4 HOLE M1 x 19, DEEP - METRIC VERION 1/2-13 UNC x 22,4 DEEP - 4 HOLE 3/8-16 UNC x 19, DEEP - 4 HOLE M12 x 22,4 DEEP - METRIC VERION M1 x 19, DEEP - METRIC VERION 26,2 5,8 26,2 12,7 24,5 1,5 x 45 52,4 88,9 52,3 P1 HAFT CODE 3 AE B INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 12/24 13 TEETH - 3 PREURE ANGLE PREURE 25,4 UCTION 63,5 PREURE 25,4 19 Parker Hannifin Manufacturing France A

20 Catalogue HY29-11/UK T7DB - Ordering Code & Dimensions Model No. T7DB series A2 HW IO 2 bolts mounting flange Displacement P1 Volumetric displacement (cm 3 /rev.) E14 = 44, E28 = 9, E17 = 55, E31 = 99,2 E2 = 66, E35 = 113,4 E22 = 7,3 E38 = 12,6 E24 = 81,1 E42 = 137,5 Displacement Volumetric displacement (cm 3 /rev.) E3 = 9,8 E9 = 28, E4 = 12,8 E1 = 31,8 E5 = 15,9 E11 = 35, E6 = 19,8 E12 = 41, E7 = 22,5 E14 = 45, E8 = 24,9 E15 = 5, Type of shaft 5 = keyed (IO G32 M) T7DB - E42 - E1-5 R - A 1 M - M P1 Modifications Ex : NOP = Not painted Ports M = 4 bolts AE flanges J518 with Metric threads = 3" P1 = 1.1/4" = 1" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM - 7 bar max. (for fire resistant fluids) 5 = 5 VITON - 7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination (see page 24) = standard Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise 9 212, ,5 114,3 38,1 7,9 87,9 6,35 MAXI 18 88,9 75,5 82,6 M1 x 2 DEEP KEY 1 x 8 (h11) 5 1,7 64, ,63 2,3 x ,8 32 +,18 +,2 35,3 MAXI 2 x 45 MOUNTING TORQUE : 68 Nm MOUNTING TORQUE : 187 Nm 125,5 9,5 HAFT CODE 5 (KEYED IO R775 G32M) M1 x 19 DEEP - 4 HOLE M16 x 28,5 DEEP - 4 HOLE M12 x 22,3 DEEP - 4 HOLE 16,7 26,2 61,9 3,2 52,4 16,4 58,7 P1 PREURE 25,4 UCTION 76,2 PREURE 31,8 2 Parker Hannifin Manufacturing France A

21 Catalogue HY29-11/UK T7DB - Ordering Code & Dimensions Model No. T7DB series - AE C 2 bolts J744 mounting flange Displacement P1 Volumetric displacement (cm 3 /rev.) E14 = 44, E28 = 9, E17 = 55, E31 = 99,2 E2 = 66, E35 = 113,4 E22 = 7,3 E38 = 12,6 E24 = 81,1 E42 = 137,5 Displacement Volumetric displacement (cm 3 /rev.) E3 = 9,8 E9 = 28, E4 = 12,8 E1 = 31,8 E5 = 15,9 E11 = 35, E6 = 19,8 E12 = 41, E7 = 22,5 E14 = 45, E8 = 24,9 E15 = 5, Type of shaft 1 = keyed (AE C) 3 = splined 12/24 (AE C) 14 teeth T7DB - E42 - E1-1 R - A 1 M - M P1 Modifications Ex : NOP = Not painted Ports M = 4 bolts AE flange J518 with Metric threads = 4 bolts AE flange J518 with UNC threads = 3" P1 = 1.1/4" = 1" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM - 7 bar max. (for fire resistant fluids) 5 = 5 VITON - 7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination (see page 24) = standard Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise 9,5 212, ,5 114,3 38,1 83,6 12,7 7,9 6,35 MAXI 17,5 88,9 75,5 82,6 KEY 7,94 / 7,89 M1 x 2 DEEP 49,3 1,7 64, , ,8 1,5 x 45 31,75 -,5 35,27 MAXI MOUNTING TORQUE : 68 Nm MOUNTING TORQUE : 187 Nm 125,5 1,3 x 45 HAFT CODE 1 (KEYED AE C) 3/8 16 UNC 19 DEEP - 4 HOLE M1 x 19, DEEP - METRIC VERION 5/8 11 UNC 28,5 DE EP - 4 HOLE M16 x 28,4 DE EP - METRIC VERION 7/16 14 UNC 22,3 DEEP - 4 HOLE M12 x 22,3 DEEP - METRIC VE RION 15,7 55,2 26,2 61,9 3,2 7,9 6,35 MAXI 38 52,4 16,4 58,7 P1 2,3 x 45 HAFT CODE 3 AE C INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 12/24 14 TEETH - 3 PREURE ANGLE PREURE 25,4 UCTION 76,2 PREURE 31,8 21 Parker Hannifin Manufacturing France A

22 Catalogue HY29-11/UK T7DD - Ordering Code & Dimensions Model No. T7DD series B4 HW IO 4 bolts mounting flange Displacement P1 & Volumetric displacement (cm 3 /rev.) E14 = 44, E28 = 9, E17 = 55, E31 = 99,2 E2 = 66, E35 = 113,4 E22 = 7,3 E38 = 12,6 E24 = 81,1 E42 = 137,5 Type of shaft 5 = keyed (IO G32 M) Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise T7DD - E42 - E22-5 R - A 1 M - M P1 Modifications Ex : NOP = Not painted Ports M = 4 bolts AE flanges J518 with Metric threads = 4" P1 & = 1.1/4" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM - 7 bar max. (for fire resistant fluids) 5 = 5 VITON - 7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination (see page 24) = standard 213,2 35, ,9 148,9 38, ,35 MAXI ,6 11,6 M1 x 2 DEEP KEY 1 x 8 (h11) ,18 +,2 64, ,63 35,3 MAXI 1,5 x 45 9,6 8,8 2 x 45 9,5 MAXI 113,2 18 MOUNTING TORQUE : 19 Nm MOUNTING TORQUE : 19 Nm 171,6 HAFT CODE 5 (KEYED IO R775 G32M) M12 x 24 DEEP - 4 HOLE 3,2 M16 x 3 DEEP - 4 HOLE 77,8 M12 x 22.3 DEEP - 4 HOLE 3,2 19,7 58,7 13,2 58,7 P1 PREURE 29,5 UCTION 11,6 PREURE 31,8 22 Parker Hannifin Manufacturing France A

23 Catalogue HY29-11/UK T7DD - Ordering Code & Dimensions Model No. T7DD series - AE C 6 bolts J744 mounting flange Displacement P1 & Volumetric displacement (cm 3 /rev.) E14 = 44, E28 = 9, E17 = 55, E31 = 99,2 E2 = 66, E35 = 113,4 E22 = 7,3 E38 = 12,6 E24 = 81,1 E42 = 137,5 Type of shaft 1 = keyed (AE C) 2 = keyed (AE CC) 3 = splined 12/24 (AE C) 14 teeth 4 = splined 16/32 (AE BB) 15 teeth Direction of rotation (shaft end view) R = Clockwise L = Counter-clockwise T7DD - E42 - E22-1 R - A 1 M - M P1 Modifications Ex : NOP = Not painted Ports M = 4 bolts AE flanges J518 with Metric threads = 4 bolts AE flange J518 with UNC threads = 4" P1 & = 1.1/4" eal class 1 = 1 BUNA N -,7 bar max. (for mineral oil) 4 = 4 EPDM - 7 bar max. (for fire resistant fluids) 5 = 5 VITON - 7 bar max. (for mineral oil and fire resistant fluids) Design letter Porting combination (see page 24) = standard 213,2 35, ,3 133,9 148,9 38,1 12,7 7,9 6,35 MAXI ,6 11,6 M1 x 2 DEEP KEY 7.94 / ,5 49,3 5 64, ,5 9,6 8,8 31,75 -,5 1,5 x45 35,3 MAXI 1,3 x ,5 181 MOUNTING TORQUE : 19 Nm MOUNTING TORQUE : 19 Nm 171,6 HAFT CODE 1 (Keyed AE C) 7/16-14UNC x 24 DEEP M12 x 24 DEEP-METRIC VERION 5/8-11UNC x 3 DEEP M16 x 3 DEEP-METRIC VERION 7/16-14UNC x 22,3 DEEP M12 x 22,3 DEEP-METRIC VERION 19,7 7, ,9 7,9 3,2 77,8 3,2 6,35 MAXI 5,8 M1 x 2 DEEP KEY 9.52 / , ,7 13,2 58,7 P1 2,3 x 45 38,1 -,5 42,36 MAXI 1,5 x 45 2,3 x 45 HAFT CODE 2 (KEYED AE CC) HAFT CODE 4 AE BB INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 16/32 15 TEETH - 3 PREURE ANGLE PREURE 29,5 UCTION 11,6 PREURE 31,8 HAFT CODE 3 AE C INVOLUTE PLINE DATA CLA 1 - FLAT ROOT IDE FIT J498b - PITCH 12/24 14 TEETH - 3 PREURE ANGLE 23 Parker Hannifin Manufacturing France A

24 Catalogue HY29-11/UK Ordering Code Porting diagrams for double pumps Pump type T7BB T7BB T7DB T7DB Pump type P1- P1- -P1- P1- P1 P1 P1 P P1- P1- P1 P1 P1 P1 P1 P P1 P P1- P1- - P1 P1 P1 P1 P1 P1 P1- P1- P1 P1 P1 P P1- P1- -P1- P1- P1 P1 P1 P1- T7DD T7DD P1- P1- P1 P1 P1 P1 P1 P1-24 Parker Hannifin Manufacturing France A

25 Catalogue HY29-11/UK Technical Data T7A - T7A Internal leakage q Vs [l/min] ct 1 ct Internal leakage (Typical) Power loss hydromechanical (Typical) 2, 1,8 1,6 1,4 1,2 1,,8,6,4,2 5 RPM 1 RPM 2 RPM 3 RPM 26 ct Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Power loss Ps [kw], Torque loss [Nm] Lp. Noise level [db(a)] 1m IO RPM 1 RPM 2 RPM 3 RPM Noise level (Typical) T7A - T7A - E2 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) Torque loss hydromechanical (Typical) RPM 1 RPM 2 RPM 3 RPM 26 ct Permissible radial load Pump information Load F [N] 9 8 = = 7 F 6 Fa 5 haft keyed peed n [rpm] Maximum permissible axial load Fa = 6 N Pump type : T7A - T7A Weight : 9,5 kg Moment of inertia : 2,6 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm Parker Hannifin Manufacturing France A

26 Catalogue HY29-11/UK Technical Data T7AW Internal leakage q Vs [l/min] Power loss Ps [kw] ct 1 ct , 2,5 2, 1,5 1,,5 Internal leakage (Typical) Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Power loss hydromechanical (Typical) 5 RPM 1 RPM 2 RPM 3 RPM 26 ct, Torque loss [Nm] Lp. Noise level [db(a)] 1m IO RPM 1 RPM 2 RPM 3 RPM 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) RPM 1 RPM 2 RPM 3 RPM Noise level (Typical) T7AW - E4 Torque loss hydromechanical (Typical) 26 ct Permissible radial load Pump information Load F [N] = = F Fa haft keyed Pump type : T7AW Weight : 11,3 kg Moment of inertia : 3,2 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm X peed n [rpm] Maximum permissible axial load Fa = 8 N 26 Parker Hannifin Manufacturing France A

27 Catalogue HY29-11/UK Technical Data T7B - T7B Internal leakage (Typical) Noise level (Typical) T7B - T7B - E1 Internal leakage q Vs [l/min] ct 1 ct Lp. Noise level [db(a)] 1m IO RPM 1 RPM 2 RPM 3 RPM 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Power loss hydromechanical (Typical) Torque loss hydromechanical (Typical) Power loss Ps [kw] 2,6 2,4 5 RPM 2,2 1 RPM 26 ct 2 RPM 2, 3 RPM 1,8 1,6 1,4 1,2 1,,8,6,4,2, Torque loss [Nm] RPM 1 RPM 2 RPM 3 RPM 26 ct Permissible radial load Pump information 16 Load F [N] 14 = = 12 F 1 Fa haft keyed Pump type : T7B - T7B Weight : 23, kg Moment of inertia : 3,2 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm peed n [rpm] Maximum permissible axial load Fa = 8 N 27 Parker Hannifin Manufacturing France A

28 Catalogue HY29-11/UK Technical Data T7D - T7D Internal leakage q Vs [l/min] Internal leakage (Typical) 26 ct 1 ct Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Lp. Noise level [db(a)] 1m IO RPM 1 RPM 15 RPM 2 RPM Noise level (Typical) T7D - T7D - E38 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) Power loss hydromechanical (Typical) Torque loss hydromechanical (Typical) Power loss Ps [kw] 4, 3,5 3, 2,5 2, 1,5 1,,5 5 RPM 1 RPM 15 RPM 2 RPM 26 ct Torque loss [Nm] 25, 2, 15, 1, 5, 5 RPM 1 RPM 15 RPM 26 ct 2 RPM, , Permissible radial load Pump information Load F [N] 22 = = 18 F 14 Fa haft keyed peed n [rpm] Maximum permissible axial load Fa = 12 N Pump type : T7D - T7D Weight : 26, kg Moment of inertia : 19,6 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm Parker Hannifin Manufacturing France A

29 Catalogue HY29-11/UK Technical Data T7BB - T7BB Internal leakage (Typical) Noise level (Typical) T7BB - T7BB - E1 - E8 Internal leakage q Vs [l/min] ct 1 ct P Lp. Noise level [db(a)] 1m IO RPM 1 RPM 2 RPM 3 RPM 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Total leakage is the sum of each section loss under its respective operating conditions. Double pump noise level is given with both stages discharging at the pressure value indicated on the curve. Power loss hydromechanical (Typical) Torque loss hydromechanical (Typical) Power loss Ps [kw] 2,6 2,4 5 RPM 2,2 1 RPM 26 ct 2 RPM P1-2, 3 RPM 1,8 1,6 1,4 1,2 1,,8,6,4,2, Torque loss [Nm] RPM 1 RPM 2 RPM 3 RPM 26 ct P Total hydromechanical power loss is the sum of each section loss under its respective operating conditions. Load F [N] Permissible radial load = = F 95 Fa haft keyed peed n [rpm] Maximum permissible axial load Fa = 12 N Pump information Pump type : T7BB - T7BB Weight : 32,6 kg Moment of inertia : 6,7 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm Parker Hannifin Manufacturing France A

30 Catalogue HY29-11/UK Technical Data T7DB - T7DB Internal leakage q Vs [l/min] Internal leakage (Typical) 26 ct 1 ct Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Total leakage is the sum of each section loss under its respective operating conditions. P1 P1 Lp. Noise level [db(a)] 1m IO Noise level (Typical) T7DB - T7DB - E38 - E1 5 RPM 1 RPM 2 RPM 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) Double pump noise level is given with both stages discharging at the pressure value indicated on the curve. Power loss hydromechanical (Typical) Torque loss hydromechanical (Typical) Power loss Ps [kw] 3,6 3,2 2,8 2,4 2, 1,6 1,2,8,4 1 RPM 2 RPM 26 ct P1, Total hydromechanical power loss is the sum of each section loss under its respective operating conditions. P1 Torque loss [Nm] RPM 2 RPM 26 ct P1 P1 Permissible radial load Pump information Load F [N] = = 175 F 15 Fa haft keyed peed n [rpm] Maximum permissible axial load Fa = 12 N Pump type : T7DB - T7DB Weight : 38,6 kg Moment of inertia : 22,7 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm Parker Hannifin Manufacturing France A

31 Catalogue HY29-11/UK Technical Data T7DD - T7DD Internal leakage q Vs [l/min] Internal leakage (Typical) 26 ct 1 ct P1- P Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 5% of theoretical flow. Total leakage is the sum of each section loss under its respective operating conditions. Lp. Noise level [db(a)] 1m IO Noise level (Typical) T7DD - T7DD - E38 - E38 5 RPM 1 RPM 15 RPM 2 RPM 26 ct Pe =.9 bar abs Lw = Lp + 8 db(a) Double pump noise level is given with both stages discharging at the pressure value indicated on the curve. Power loss hydromechanical (Typical) Torque loss hydromechanical (Typical) Power loss Ps [kw] 4, 3, 2, 1, 5 RPM 1 RPM 15 RPM 2 RPM 26 ct P1- Torque loss [Nm] 25, 2, 15, 1, 5, 5 RPM 1 RPM 15 RPM 2 RPM 26 ct P1-, Total hydromechanical power loss is the sum of each section loss under its respective operating conditions., Load F [N] Permissible radial load = = 175 F 15 Fa haft keyed peed n [rpm] Maximum permissible axial load Fa = 12 N Pump information Pump type : T7DD - T7DD Weight : 56, kg Moment of inertia : 36,3 Kgm 2 x 1-4 Input torque limit : haft Vi [cm 3 /rev] x p max. [bar] Nm Parker Hannifin Manufacturing France A

32 Catalogue HY29-11/UK Pump election Pump selection example 1 The starting point is to collect the hydraulic parameters of the machine cycle : The fluid type. The duration, the pressure and the flow values. Example: The fluid is IO VG32 mineral oil, and the cycle described in a table. 2 Calculate the total time of the cycle and the average pressure of the cycle Total cycle time = NN =,6 +,3 + 1, ,5 +,3 +,6 + 1 = 11,8 seconds ii=1 tt ii Average pressure = NN / ii=1(pp ii tt ii ) NN ii=1 tt ii ((11 x,6) + (14 x,3) + (155 x 1,5) + (11 x 1) + (15 x 6,5) + (155 x,3) + (11 x,6) + (5 x 1)) / 11,8 = 11 bar 3 First estimation of the pump size based on the flow requirement and a median Max speed". Biggest flow requirement = 95 lpm Median Max speed = 25 rpm a 95/25 x 1 = 38 cm 3 /rev 4 From the catalogue tables, select a pump that can operate with the fluid type of the application at the max pressure and the Median Max speed. Fluid is HF- HF2 Mineral oil p max = 155 bar Median Max speed = 25 rpm ee speed and pressure ratings in the main technical data tables. a Let s try a T7B E11 pump with Vi = 35 cm 3 /rev which seems to be acceptable 5 Report the flow loss of this pump for each working pressure. Read T7B flow losses from graphs page 27 - Use 26 or 1 ct curve depending on the working conditions. - An average value of the two curves may also be selected 6 Calculate the real flows the pump has to supply for each step of the cycle. Q real. = Q + q vs 7 Calculate the pump rotation speed for each step of the cycle. n = Q real x (1 3 / Vi ) 8 Calculate the theoretical torque for each step of the cycle. T theo. = (Vi x p) / (2 x p) 9 Report the torque loss of this pump for each working pressure and operating speed. Read T7B torque losses from graph page 27 1 Calculate the real torque requirement for each step of the cycle. T real. = T theo. + T loss. 32 Parker Hannifin Manufacturing France A

33 Catalogue HY29-11/UK Pump election 11 Compare the torque requirements to the maximum input torque of the selected pump. Maximum input torque for T7B E11 pump with shaft type 2 : Read the technical data on page 27. Tmax = 327 Nm Tmax must be highest than the larger of T real. value. If not, select another pump with a stronger shaft and re start from point Compare the highest rotation speed of the pump during the cycle with the maximum speed rating of the selected pump. Maximum speed rating of the T7B E11 pump (read the main technical data on page 4) = 34 rpm. Maximum speed in cycle = 28 rpm. Maximum speed during cycle must be lower than the maximum speed rating of the pump. If not, select another pump with a higher speed rating or a bigger displacement and re start from point For each cycle step, identify the step operating mode in the pump operating range chart. Cross pump pressure and speed values on the T7B E11 "pump operating range" chart page 9 : Continuous or Intermittent. 14 For each Intermittent cycle step, verify that the flow requirement Q is acceptable for the respective step duration t. Read the max possible time duration value in "the time restriction at low flow" chart..in case the step is not Acceptable, correct the Q value to get an Acceptable cycle step Mineral oil IO VG32 2 T7B E11 vi = 35 cm 3 /rev Time t [sec] Pressure p [bar] Flow Q [l/min] Pump losses q vs [l/min] upply flow Q real. [l/min] Pump speed n [rpm] T theo. torque [Nm] T p & rpm [Nm] T real. torque [Nm] Operating mode Mould close, , 72, 25 61,3 3,5 65 C A Tonnage, ,2 52, , 4, 82 C A Injection 1, ,8 97, ,4 5, 92 C A Injection hold 1, , 18, 5 61,3 2,5 64 C A Curing 6, , 92, ,5 4, 63 C A Decompression, ,8 42, ,4 4, 91 C A Mould open, , 52, 15 61,3 3, 65 C A Ejection 1, 5 3 1, 31, 9 27,9 2, 3 C A Total cycle 11,8 Average cycle pressure Cycle step status The preselection of the pump is now complete. It is a preselection only as it is now time to find a suitable electric motor to match with the application parameters, and this may lead to reconsider this preselected pump. For the best choice being the best compromise, it may also happen to change the displacement of the preselected pump at the time to fine tune the new complete system. Parker is also offering a broad range of assembled Drive Controlled Pump systems. In order to easily select these Drive Controlled Pump packages, Parker offers a unique software tool : The DriveCreator. Please consult your local Parker office. 33 Parker Hannifin Manufacturing France A

34 Catalogue HY29-11/UK Pump election How to use the time restriction tables q vs - Graph for pump type 1 T7B E15 : Vi = 5 cm 3 /rev tep time duration : 3 sec Pressure : 16 bar Needed output flow : 4 l/mn Continuous Zone = No time restriction This cycle step is acceptable with Pump Min speed = (Q + q vs ) x (1 3 / Vi) - Graph for pump type 2 T7B E15 : Vi = 5 cm 3 /rev tep time duration : 18 sec Pressure : 2 bar Needed output flow : 3,5 l/mn Intermittent Zone = Time restriction Read time restriction value for 2 bar curve T Max = 325 > 18 sec This cycle step is acceptable with Pump Min speed = (Q + q vs )x(1 3 / Vi) - Graph for pump type 3 T7B E15 : Vi = 5 cm 3 /rev tep time duration : 4 sec Pressure : 2 bar Needed output flow : 3,5 l/mn Intermittent Zone = Time restriction Read time restriction value for 2 bar curve T Max = 325 < 4 sec This cycle step is not acceptable An additional flow amount must be added in order to perform this step INTERMITTENT 24 1 bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) INTERMITTENT 24 1 bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) INTERMITTENT 24 1 bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) Time limit [sec] Time limit [sec] Time limit [sec] - Graph for pump type 4 T7B E15 : Vi = 5 cm 3 /rev tep time duration : 4 sec Pressure : 2 bar Needed output flow :? Read on the 2 bar curve the needed flow value allowing more than 4 sec : 5 l/mn This cycle step is acceptable with Pump Min speed = (Q + q vs ) x (1 3 / Vi) INTERMITTENT 24 1 bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) Time limit [sec] 34 Parker Hannifin Manufacturing France A

35 Catalogue HY29-11/UK Pump election Time restriction at low flow T7A - T7A E6 - E1 - E11 - E13 T7A - T7A E17 - E2 - E22 T7A - T7A E INTERMITTENT 26 ct bar bar bar bar bar bar CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 Q = Needed output flow [l/min) 3 28 INTERMITTENT 26 ct bar bar bar bar bar bar 5 2 CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 Q = Needed output flow [l/min) INTERMITTENT 26 ct bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 Q = Needed output flow [l/min) Time limit [sec] Time limit [sec] Time limit [sec] 35 Parker Hannifin Manufacturing France A

36 Catalogue HY29-11/UK Pump election Time restriction at low flow T7AW E22 - E26 - E INTERMITTENT 26 ct bar bar bar bar bar bar CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 Q = Needed output flow [l/min) Time limit [sec] T7AW E3 - E32 T7AW E35 - E36 - E INTERMITTENT 26 ct bar bar bar bar bar bar CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 Q = Needed output flow [l/min) 28 5 INTERMITTENT 26 ct bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 Q = Needed output flow [l/min) Time limit [sec] Time limit [sec] 36 Parker Hannifin Manufacturing France A

37 Catalogue HY29-11/UK Pump election Time restriction at low flow T7B - T7B E3 - E4 - E5 - E INTERMITTENT 1 bar 16 bar 26 ct 2 bar 24bar 28 bar 32 bar CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) Time limit [sec] T7B - T7B E7 - E8 - E9 - E1 T7B - T7B E11 - E12 - E INTERMITTENT 26 ct 26 1 bar bar 2 2 bar bar bar bar CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) INTERMITTENT 26 ct bar bar 18 2 bar bar bar bar CONTINUOU,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) Time limit [sec] Time limit [sec] T7B - T7B E INTERMITTENT 26 ct bar bar bar bar bar CONTINUOU 5,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q = Needed output flow [l/min) Max time [sec] 37 Parker Hannifin Manufacturing France A

38 Catalogue HY29-11/UK Pump election Time restriction at low flow T7D - T7D E14 - E17 - E INTERMITTENT 1 bar 16 bar 2 bar 24 bar 26 ct 3 bar CONTINUOU Q = Needed output flow [l/min) Time limit [sec] T7D - T7D E22 - E24 - E28 - E31 T7D - T7D E35 - E INTERMITTENT 26 ct bar bar bar bar bar CONTINUOU Q = Needed output flow [l/min) 28 5 INTERMITTENT 26 ct bar bar bar bar bar CONTINUOU Q = Needed output flow [l/min) Time limit [sec] Time limit [sec] T7D - T7D E ct 24 INTERMITTENT bar bar 35 2 bar bar bar CONTINUOU Q = Needed output flow [l/min) Max time [sec] 38 Parker Hannifin Manufacturing France A

39 Catalogue HY29-11/UK Circuit Design Circuit design Holding the pressure When a high pressure has to be held over a long period of time, the design of the hydraulic circuit must be carefully considered. If the pressure has to be held more than 1 minutes, a hydraulic circuit with an accumulator may be energywiser. Pressure hold function in Flow control mode To improve the energy efficiency of the system, the rotation speed of the pump is usually reduced during the pressure holding steps. Depending on the pressure value that needs to be held, the rotation speed of the pump can be reduced down to its corresponding minimum. pecific Circuit design for operating in pressure control mode Operating a pump with a variable speed drive in pressure control mode requires the hydraulic circuit to be designed taking the following points into account. A pressure relief valve is still needed as a safety device. A bypass line must be included in the hydraulic circuit. It will provide the necessary cooling flow for the pump and help in stabilizing the fluid viscosity in order to achieve a stable pressure regulation. The bypass line can be activated by an on/off directional control valve when the system is above a certain pressure value and below a certain speed value. U P X Example of bypass line circuitry : The size of the orifice is depending on the maximum pressure value to be regulated, and the pump type. FCU Determination of the necessary bypass flow: Q Bypass@p = q vs + Q yst q vs : internal flow loss of the pump at the operating pressure p. Q yst : flow amount that is necessary to compensate the leakages of the actuators and valves, and to compress the oil volume. Internal leakage q Vs [l/min] Internal leakage (Typical) ct 1 ct Example: Pump T7B E9 operating at p = 24 bar IO VG32 mineral oil at approx 45 C Vi T7B E9 = 28 cm 3 /rev Estimation based on the circuit design, Q yst = 1 lpm Value Read from the T7B technical data page, q vs = 3 lpm Q Bypass@p = = 4 lpm Estimation of the orifice diameter to get at least 4 lpm at 24 bar a,7 mm (Values measured with mineral oil at a viscosity of 4 ct and 5 C) 39 Parker Hannifin Manufacturing France A

40 Catalogue HY29-11/UK Circuit Design Decompression : The T7 pumps for variable speed drives may be operated in a 2 quadrant mode: - Pump mode : flow is going from the "" to the "P" port - Motor mode : flow is going from the "P" to the "" port The Rotation way described in the pump model description is corresponding to the pump mode. Never install a check valve on the "P" discharge line of the pump when a reverse rotation way is enabled. pecial care has to be taken for the transition between cycle steps, in particular for the switch of the directional control valves. When operating the pump in pressure control mode, this is of the utmost importance. In this case, the pressure set value must be ramped down before switching to flow control mode and then energizing the directional control valve. The technology of the T7 pumps for variable speed drives is allowing a quick natural decompression of the pressure line without the need to reverse the rotation way of the E motor. Only very fast cycling machines may require to reverse the rotation way in order to decompress the presure line in a very short time. In such a case, care must be taken that the pressure line remains positive at all time as to avoid any cavitation noise and wear to occur. Negative speed values in the range of -5 rpm could be considered. Dynamic characteristics The dynamic characteristic of a hydraulic system is depending on many parameters, the hydraulic pump being only one of these. This is why it is not possible in a pump catalogue to indicate precise dynamic values. We would like however to point out the following : - The moment of inertia of the pump is mentioned on its data page of this catalogue. - In flow control mode, the pump response time will be depending on the dynamic performances of the electric motor used, its drive unit and the oil circuitry. Flow response times in the same range or shorter than variable displacement load sensing pumps are achievable. - When assembled to servo motors, fast drives and fast sensors, our pumps are allowing a closed loop pressure control suitable for many applications. Example : Fluid : 26 ct Mineral oil Pump : T7B E14 ervomotor : MH 265 eries Control loop system : - Closed loop pressure control - Closed loop speed control - Closed loop motor torque control Output Pressure [bar] Pump peed [rpm] Inlet Pressure [bar] UP Acceleration from1 to 25 rpm Pressure rise from 1 to 14 bar DOWN Depressurization from 14 to 1bar Deceleration from 25 to 1 rpm 1 1 Time [s] Inlet line : 1.1/2 Inlet line : 6 mm long and flooded Discharge line : 1 Discharge length : 12 mm T speed up : 65 ms T pressure up : 75 ms T pressure down : 75 ms T speed down : 6 ms 4 Parker Hannifin Manufacturing France A

41 Catalogue HY29-11/UK Circuit Design Pump installation Pump mounting The environment of the pump has to be taken into consideration as to avoid noise reflection, pollution and shocks. These pumps are designed to operate in any position. Always prefer an installation with a flooded inlet or with the pump inside the oil tank. The installation of the pump on the top of the tank should be restricted to the operation in Flow Mode with moderate dynamic requirements. In such a case the inlet pipe of the pump must be sized according to the max discharge flow in order to keep the inlet velocity below 1,5 m/s. d [mm] Inner diameter of the inlet pipe or hose v [m/s] Average velocity d = Q [L/min] Inlet flow 4 Q p v Q v haft and coupling data - haft loads : These products are primarily designed for coaxial drives which do not impose axial or side loading on the shaft. The max. permissible load values are indicated on the pump technical data page. Contact Parker for specific applications. - Keyed shafts : Parker supplies its keyed shaft pumps with high strength heat-treated keys. Therefore, when installing or replacing these pumps, the heat-treated keys must be used in order to ensure maximum life in the application. If the key is replaced, it must be a heat-treated key between 27 and 34 R.C. hardness. The corners of the keys must be chamfered by,76 mm to 1,2 mm (.3 to.4) at 45 to clear the radii in the key way. The alignment of the keyed shafts must be within the tolerances given for the splined shafts here below. - Couplings and female splines : The coupling must be selected to minimize the load on the shaft (weight, misalignment). The female spline must be made to conform to the Class 1 fit as described in AE-J498b (1971). This is described as a Flat Root ide Fit. The mating female spline should be free to float and find its own center. If both members are rigidly supported, they must be aligned within,15 TIR (.6 TIR) or less to reduce fretting. The angular alignment of two splines axes must be less than ±,5 per 25,4 radius (±.2 per 1 radius). The coupling must be hardened to a hardness between 29 and 45 HRC. The coupling spline must be lubricated with a lithium molydisulfide grease, disulfide of molybdenum or a similar lubricant. Fluid connections Keep a maximum distance between the suction pipe and the return lines in the tank. A bevel of min 45 on suction and return lines is recommended in order to lower the fluid velocity. Fluid lines must be adequate size and strength to assure free flow through the pump. An undersized inlet pipe will prevent the pump from operating properly at full rated speed. An undersized outlet line will cause back pressure, heat generation and noise increase. If the pump is inside the tank, use a short inlet pipe. Flexible hose lines are recommended. If rigid piping is used, the workmanship must be accurate to eliminate strain on the pump ports or to the fluid connections. harp bends in the lines must be eliminated wherever possible. All system piping must be cleaned and flushed before installing the pump. 41 Parker Hannifin Manufacturing France A

Industrial Hydraulic Pumps T7E, T7ES. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Industrial Hydraulic Pumps T7E, T7ES. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement Industrial T7E, T7E Denison Vane Technology, fixed displacement Hydraulic Motors Hydraulic Valves Hydraulic Cylinders Hydraulic Filtration Hydraulic Accumalators We are doing our parts to keep you moving!

More information

Industrial Hydraulic Pumps T7DBB, T7DBBS. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Industrial Hydraulic Pumps T7DBB, T7DBBS. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement Industrial T7DBB, T7DBBS Denison Vane Technology, fixed displacement Hydraulic Motors Hydraulic Valves Hydraulic Cylinders Hydraulic Filtration Hydraulic Accumalators We are doing our parts to keep you

More information

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement Mobile Hydraulic Pumps T6G, T67G, T6ZC Denison Vane Technology, fixed displacement aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing

More information

Hydraulic Pump T7AS/T7ASW Series Vane Pumps

Hydraulic Pump T7AS/T7ASW Series Vane Pumps Hydraulic ump T7A/T7AW eries Vane umps ressure up to 3 bar Fixed Displacement from 6 to 4 ml/rev. Catalogue HY29-8/UK April 26 Catalogue HY29-8/UK General Characteristics General T7A T7AW Vane umps T7A

More information

DENISON HYDRAULICS vane pumps - single, double, triple T6 mobile application.

DENISON HYDRAULICS vane pumps - single, double, triple T6 mobile application. DENISON HYDRAULICS vane pumps - single, double, triple T6 mobile application. Publ. 1 - AM0701 - A 11 / 98 / 2000 / FB Replaces : 1 - AM 075 - A CONTENTS - T6 SERIES MOBILE APPLICATION GENERAL Features...

More information

Vane motor high performance hydraulic series M5B - M5BS - M5BF

Vane motor high performance hydraulic series M5B - M5BS - M5BF Vane motor high performance hydraulic series M5B - M5BS - M5BF Publ. 2 - AM172 - B 1 / 25 / FB Replaces : 2 - AM172 - A L11-2172 - 2 CHARACTERISTICS - M5B* SERIES LOW NOISE MOTOR 12 vanes and a patented

More information

Vane pumps single, double & triple T6 mobile application zp20

Vane pumps single, double & triple T6 mobile application zp20 Vane pumps single, double & triple T6 mobile application zp20 Publ. 1 - AM0701 - A 11 / 98 / 2000 / FB Replaces : 1 - AM 075 - A FEATURES - T6 SERIES MOBILE APPLICATION GREATER FLOW HIGHER PRESSURE BETTER

More information

Mobile Hydraulic Pumps T6DCCM. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Mobile Hydraulic Pumps T6DCCM. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement Mobile Hydraulic Pumps T6DCCM Denison Vane Technology, fixed displacement Hydraulic Pumps Hydraulic Motors Hydraulic Valves Hydraulic Cylinders Hydraulic Filtration Hydraulic Accumalators We are doing

More information

Mobile Hydraulic Pumps T6DCM, T6DCP, T6DCMW. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Mobile Hydraulic Pumps T6DCM, T6DCP, T6DCMW. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement Mobile Hydraulic Pumps T6DCM, T6DCP, T6DCMW Denison Vane Technology, fixed displacement Hydraulic Pumps Hydraulic Motors Hydraulic Valves Hydraulic Cylinders Hydraulic Filtration Hydraulic Accumalators

More information

Vane pumps single, double & triple T6 mobile application zp20

Vane pumps single, double & triple T6 mobile application zp20 Vane pumps single, double & triple T6 mobile application zp20 Publ. 1 - AM0701 - A 11 / 98 / 2000 / FB Replaces : 1 - AM 075 - A FEATURES - T6 SERIES MOBILE APPLICATION GREATER FLOW HIGHER PRESSURE BETTER

More information

High Pressure Single Vane Pump T6C/T6D Series

High Pressure Single Vane Pump T6C/T6D Series High ingle Vane Pump T6C/T6D eries Features T6C and T6D eries are fixed displacement and balanced type single vane pumps. The pump is designed for higher operating pressure and greater flow at the same

More information

Mobile Hydraulic Pumps T6EM, T6EP. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Mobile Hydraulic Pumps T6EM, T6EP. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement Mobile Hydraulic Pumps T6EM, T6EP Denison Vane Technology, fixed displacement Hydraulic Pumps Hydraulic Motors Hydraulic Valves Hydraulic Cylinders Hydraulic Filtration Hydraulic Accumalators We are doing

More information

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40 Axial piston variable pump A4VG eries 40 RE 92004 Edition: 07.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit up to 500 bar ize 110...280 Nominal pressure 450 bar Maximum

More information

Fixed Displacement Pump A2FO

Fixed Displacement Pump A2FO RE 91401/01.97 Brueninghaus Hydromatik eries 6, for open circuits Axial tapered piston - bent axis design izes 5...1000 Nom. Pressure up to 400 bar Peak Pressure up to 4 bar RE 91401/01.97 replaces 11.95

More information

Axial Piston Fixed Pump A2FO

Axial Piston Fixed Pump A2FO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Fixed Pump A2FO RE 91401/03.08 1/24 Replaces: 09.07 Technical data sheet eries 6 izes Nominal

More information

Variable Axial Piston Pump A10V Series - 52/53

Variable Axial Piston Pump A10V Series - 52/53 Variable Axial Piston Pump A10V eries - 52/53 eries 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) izes 10cm 3 /rev - 63cm 3 /rev (0.64in 3 /rev-3.8in 3 /rev)

More information

P2060 P2075 P2105 P2145 P3105 P3145

P2060 P2075 P2105 P2145 P3105 P3145 Technical Information Technical Features P2 Series Compact design Low noise level Service friendly Reliable Long-lasting Flexible Easy to install High self-priming speed Technical Data P3 Series P2 Series

More information

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40 Axial piston variable pump A4VG eries 40 RE 92004 Edition: 02.2017 Replaces: 07.2016 High-pressure pump for applications in a closed circuit up to 500 bar ize 110...280 Nominal pressure 450 bar Maximum

More information

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40 Axial piston variable pump A4VG eries 40 RE 92004 Edition: 09.2017 Replaces: 02.2017 High-pressure pump for applications in a closed circuit up to 500 bar ize 110 280 Nominal pressure 450 bar Maximum pressure

More information

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces:

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces: Axial piston variable pump A4VG eries 40 Americas RE-A 92004 Edition: 09.2017 Replaces: 06.2012 High-pressure pump for applications in a closed circuit up to 7250 psi (500 bar) ize 110 280 Nominal pressure

More information

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) Vickers Vane Pumps VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) 5008.00/EN/0596/A A.25 Introduction From the

More information

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RA 92703/11.07 1/44 Replaces: 06.07 Data sheet eries 52/53 ize 10...85

More information

2-Circuit Axial Piston Fixed Pump A18FDO

2-Circuit Axial Piston Fixed Pump A18FDO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice 2-Circuit Axial Piston Fixed Pump A18FDO E 91540/03.10 1/12 eplaces: 06.09 Data sheet eries 10 ize 63,

More information

KT6 Series Variable Displacement Vane Pumps

KT6 Series Variable Displacement Vane Pumps Care in Application 1. Check speed range, pressure, temperature, fluid quality, viscosity and pump rotation. 2. Check inlet conditions of the pump, if it can accept application requirment. 3. Type of shaft

More information

Axial Piston Fixed Pump A17FNO

Axial Piston Fixed Pump A17FNO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Fixed Pump A17FNO RE 91510/03.10 1/12 Data sheet eries 10 ize 125 Nominal pressure 250 bar

More information

Axial piston variable pump A10V(S)O Series 31

Axial piston variable pump A10V(S)O Series 31 Axial piston variable pump A10V()O eries 31 RE 92701 Edition: 06.2016 Replaces: 01.2012 ize 18 (A10VO) izes 28 to 1 (A10VO) Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Features Variable

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, Variable displacement axial piston pumps, Edition: 04/04.2000 Replaces: 04/10.99 DISPLACEMENTS From To PRESSURE Max. continuous Max. intermittent Max. peak 29 cm 3 /rev 73 cm 3 /rev 280 bar 315 bar 350

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, ariable displacement axial piston pumps, for open circuit DISPLACEMENTS From To 2.75 in 3 /rev (45 cm 3 /rev) 5.12 in 3 /rev (84 cm 3 /rev) MAX SPEED 3000 min -1 PRESSURE Max. continuous Max. intermittent

More information

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW AXIAL PISTON PUMPS SHPV SECTIONAL VIEW 2 SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working loop (high pressure) working loop (low pressure) control fluid suction line case drain fluid Above figure shows schematically

More information

Axial piston fixed pump AA2FO

Axial piston fixed pump AA2FO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial piston fixed pump AA2FO RA-A 91401/07.2014 1/32 Replaces: 03.08 Data sheet eries 6 izes Nominal pressure/maximum

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, LVP 04 T E Variable displacement axial piston pumps, Edition: 04/04.2000 Replaces: 04/10.99 DISPLACEMENTS From To PRESSURE Max. continuous Max. intermittent Max. peak 29 cm 3 /rev 73 cm 3 /rev 280 bar

More information

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces: Axial piston variable pump A10V()O eries 31 Americas RE-A 92701 Edition: 02.2017 Replaces: 03.2012 ize 18 (A10VO) izes 28 to 140 (A10VO) Nominal pressure 4100 psi (280 bar) Maximum pressure 5100 psi (350

More information

Internal Gear Pumps. Series QX. Reference: 100-P E-10 1/32. Issue:

Internal Gear Pumps. Series QX. Reference: 100-P E-10 1/32. Issue: Internal Gear Pumps eries QX Reference: -P-000021-E-10 Issue: 11.2011 1/32 2/32 Contents Page 1 General... 5 1.1 Product description... 5 1.2 Advantages... 5 2 Technical data... 5 2.1 General (deviating

More information

Technical Information Series 45 H Frame powersolutions.danfoss.com

Technical Information Series 45 H Frame powersolutions.danfoss.com MAKING MODERN LIVING POILE Technical Information eries 45 H Frame powersolutions.danfoss.com Contents Frame H Design... 4 pecifications... 5 Performance H57... 6 Performance H75D... 7 Order code... 8 Controls...

More information

Vane motors Single & double M3B - M4 / M4S series

Vane motors Single & double M3B - M4 / M4S series Vane motors Single & double M3B - M4 / M4S series Publ. 2 - AM 157 - B 07 / 97 / FB Replaces : 2 - AM 157 - A CONTENTS - M3* AND M4* SERIES GENERAL General characteristics... 3 Technical data... 4 General

More information

DT6 TRIPLE VANE PUMPS DT6 TRIPLE VANE PUMPS ORDERING CODE DATA SHEET. 84 tdz.com bezares.com. Seal Class. Design letter

DT6 TRIPLE VANE PUMPS DT6 TRIPLE VANE PUMPS ORDERING CODE DATA SHEET. 84 tdz.com bezares.com. Seal Class. Design letter DT6 TRIPLE VANE PUMP DT6 TRIPLE VANE PUMP ORDERING CODE DATA HEET DT6-DCC-B- I 6/38/70-1-R-00-B-1-00 pecial threads(ask for available threads) UNC: 00, 01 Metric: M0, M1 eal Class Design letter 1:NBR 5:VITON

More information

Axial piston variable pump A10VSO series 32

Axial piston variable pump A10VSO series 32 xial piston variable pump 10VO series 32 RE 92714 Issue: 10.2014 Replaces: 06.2011 izes 45 to 180 Nominal pressure 280 bar Maximum pressure 350 bar For industrial application areas Open circuit Characteristics

More information

Axial piston variable pump A10VSO Series 31

Axial piston variable pump A10VSO Series 31 Axial piston variable pump A10VO eries 31 RE 92711 Edition: 10.2016 Replaces: 01.2012 All-purpose medium pressure pump izes 18 to 140 Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Features

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

ENGINEERING DATA. Variable Axial Piston Pump A10V Series - 52/53. w w w. F l u i D y n e F P. c o m E m a i l : F l u i D y n e F P.

ENGINEERING DATA. Variable Axial Piston Pump A10V Series - 52/53. w w w. F l u i D y n e F P. c o m E m a i l : F l u i D y n e F P. ENGINEERING DATA Variable Axial Piston Pump A10V eries - 52/53 eries 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) izes 10cm 3 /rev - 63cm 3 /rev (0.64in 3

More information

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces: Axial piston variable pump A10VO series 32 Americas RE-A 92714 Issue: 02.15 Replaces: 06.11 izes 45 to 180 Nominal pressure 4100 psi (280 bar) Maximum pressure 5100 psi (350 bar) For industrial application

More information

ORDERING CODE - SERIES DT DT6 DOUBLE VANE PUMPS ORDERING CODE DATA SHEET. 72 tdz.com bezares.com DT6* I - CC - * - B -17/14-1- R-00 -B- 1-00

ORDERING CODE - SERIES DT DT6 DOUBLE VANE PUMPS ORDERING CODE DATA SHEET. 72 tdz.com bezares.com DT6* I - CC - * - B -17/14-1- R-00 -B- 1-00 ORDERING CODE - ERIE DT DT6 DOUBLE VANE PUMP ORDERING CODE DATA HEET DT6* I - CC - * - B -17/14-1- R-00 -B- 1-00 pecial threads (ask for available threads) UNC: 00, 01, 10, 11 Metric: 0M, W0, 1M, W1 eal

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

Axial piston variable pump A10VO Series 32

Axial piston variable pump A10VO Series 32 Axial piston variable pump A10VO eries 32 RE 92705 Edition: 06.2016 Replaces: 01.2012 Optimized medium pressure pump for powerful machines izes 45 to 180 Nominal pressure 280 bar Maximum pressure 350 bar

More information

Vane motors Single & double zm21 M3B - M4 / M4S series

Vane motors Single & double zm21 M3B - M4 / M4S series Vane motors Single & double zm21 M3B - M4 / M4S series Publ. 2 - AM 157 - B 07 / 97 / FB Replaces : 2 - AM 157 - A CHARACTERISTICS - M3* AND M4* SERIES HIGH STARTING TORQUE EFFICIENCY HIGH VOLUMETRIC EFFICIENCY

More information

Variable Displacement Pump A4VG for closed circuits

Variable Displacement Pump A4VG for closed circuits RE 92 003/05.99 RE 92 003/05.99 replaces: 02.98 Variable Displacement Pump A4VG for closed circuits Sizes 28...250 Series 3 Nominal pressure 400 bar Peak pressure 450 bar A4VG...EP Index Features 1 Ordering

More information

SERIES HYDRAULIC MOTORS

SERIES HYDRAULIC MOTORS ERIE HYDRULIC MOTOR overview The eries motor is the leader in its class, offering high efficiency and durability. The three-zone orbiting valve, laminated manifold and Roller tator motor work harmoniously

More information

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces:

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces: Axial piston variable pump (A)A10VO eries 31 Americas RE-A 92711 Edition: 04.2017 Replaces: 04.2012 All-purpose medium pressure pump izes 18 to 140 Nominal pressure 4100 psi (280 bar) Maximum pressure

More information

UŽSISAKYKITE internetu telefonu el. paštu

UŽSISAKYKITE internetu  telefonu el. paštu Features Axial piston pump MA10VO in swashplate design is used in open loop circuits. Flow is proportional to drive speed and displacement. By adjusting the position of the swashplate it is possible to

More information

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A10VSO Axial Piston Variable Pump A10VO RE 92711/01.12 1/48 Replaces: 06.09 and RE 92707/11.10 Data sheet eries 31 izes 18 to 1 Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Contents Type code

More information

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series General Information General Information P2 Series The newly developed variable displacement piston pumps from Parker Hannifin, designated P2, are intended for mobile applications, featuring a very compact

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.

More information

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed

More information

Axial Piston Variable Pump A10VSNO

Axial Piston Variable Pump A10VSNO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VNO RE 92741/03.11 1/16 Data sheet eries 52 ize 15 Nominal pressure 210 bar

More information

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93 Vickers Vane Pumps Double Thru-drive Vane Pumps High speed, high pressure VQT Series for mobile equipment Released 7/93 612 Introduction Double VQT high performance pumps are fixed displacement units that

More information

Axial piston fixed pump A17FO Series 10

Axial piston fixed pump A17FO Series 10 Axial piston fixed pump A17FO eries 10 E 91520 Issue: 11.2015 eplaces: 10.2014 High-pressure pump for use in commercial vehicles izes 23 to 107 Nominal pressure/maximum pressure 350/400 bar Bent-axis design

More information

Axial piston fixed pump A17FNO Series 10

Axial piston fixed pump A17FNO Series 10 Axial piston fixed pump A17FNO eries 10 E 91510 Issue: 11.2015 eplaces: 06.2012 Designed for use in commercial vehicles with standard pressure requirements ize 125 Nominal pressure/maximum pressure 250/300

More information

Hydraulic Motor/Pump Series F11/F12 zp12

Hydraulic Motor/Pump Series F11/F12 zp12 Hydraulic Motor/Pump zp12 Fixed Displacement zp11 Catalogue HY17-8249/US March 2004 Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5 psi 1 l...0.264 US gallon 1 cm

More information

AXIAL PISTON MOTORS SHMF

AXIAL PISTON MOTORS SHMF SECTIONAL VIEW Purge relief valve High pressure relief valves (adjustable) Cylinder block assembly Shaft seal Output shaft Valve block Shuttle valve Swashplate 2 SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working

More information

VT6ED - VT6EDM - VT6EDP Double vane pump

VT6ED - VT6EDM - VT6EDP Double vane pump ervice Information 4-0007 - M - P Double vane pump. 3 4 Bold printed are recommended repair kits and assemblies 0r 0 9 9r 6 Mounting torque Item pos. 4 5 ft-lbs 38 38 N-m 87 87 7 7 8 b P 8b 8a 8d 5 0g

More information

Axial Piston Variable Pump A18VLO Series 11

Axial Piston Variable Pump A18VLO Series 11 Axial Piston Variable Pump A18VLO eries 11 RE 92280 Issue: 06.2012 Replaces: 06.2009 ize 80 Nominal pressure 350 bar Maximum pressure 400 bar For commercial vehicles Open circuit Features Variable pump

More information

Hydraulic Motor M5A*/M5B* Series Vane Motors

Hydraulic Motor M5A*/M5B* Series Vane Motors Hydraulic Motor M5*/M5* Series Pressure up to 32 bar Fixed Displacement from 6 to 45 ml/rev. Catalogue HY29-18/UK December 26 Catalogue HY29-18/UK Content General M5* / M5* Warning... 2 General characteristics...

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.

More information

VT67DB Double vane pump

VT67DB Double vane pump ervice Information 4-000 Double vane pump. 0 9 0q 9q 4 5 6 8 Mounting torque Item pos. N-m 68 8 ft-lbs 50 8 8b 8a 8d 8c ITEM 0q INCLUDED 0d 0h 0g 0f haft Code - 0e 0c 0b 0a haft Code - haft Code - haft

More information

Piston Pumps Series P2 / P3 Variable Displacement

Piston Pumps Series P2 / P3 Variable Displacement Piston Pumps Series P2 / P3 Variable Displacement Catalogue HY11-2600/UK July 2003 Contents Series P2/P3 Description Technical information 3 Ordering code 4 Control options LA and LB 6 Control options

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.

More information

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model AA4VSE Plug-in dual displacement motor Series Axial piston swashplate design, SAE model RE 91808/09.90 RE 91808/09.90 Brueninghaus Hydromatik Size 250 Nominal pressure 350 bar Peak pressure 400 bar High

More information

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO Axial Piston Variable Pump A10VO RE 92705/01.12 1/44 Replaces: 06.09 Data sheet eries 32 izes 71 to 180 Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Contents Type code for standard program

More information

Axial piston variable pump A1VO series 10

Axial piston variable pump A1VO series 10 Axial piston variable pump A1VO series 10 RE 92650 Edition: 09.2013 Replaces: 02.2013 izes 18, 35 Nominal pressure 250 bar Maximum pressure 280 bar Open circuit Features Variable axial piston pump of swashplate

More information

Axial piston variable pump A1VO Series 10

Axial piston variable pump A1VO Series 10 Axial piston variable pump A1VO eries 10 RE 92650 Edition: 06.2016 Replaces: 08.2015 For load-sensing-systems in smaller working machines izes 18, 28, 35 Nominal pressure 250 bar Maximum pressure 280 bar

More information

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW AXIAL PISTON PUMPS SHPV SECTIONAL VIEW 2 AXIAL PISTON PUMPS SHPV SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working loop (high pressure) working loop (low pressure) control fluid suction line case drain fluid

More information

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES TQ/TV THRU-DRIVE HYDRAULIC VANE PUMPS TQ/TV SERIES Thru-drive pumps save installation space and cost by eliminating double shaft extension electric motors or

More information

HPV-15 AXIAL PISTON PUMPS

HPV-15 AXIAL PISTON PUMPS SPECIFICATIONS Variable Displacement, Pressure Compensated OVERALL EFFICIENCY EFFICIENCY - % 1 9 8 7 6 bar 34 69 13 138 172 27 241 TYPICAL PERFORMANCE SPECIFICATIONS VOLUMETRIC cu. in./rev. 2.9 DISPLACEMENT

More information

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A10VSO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RE 92714/06.11 1/44 Replaces: 07.10 and RE 92707 Data sheet eries 32 ize

More information

Axial Piston Fixed Motor A2FM

Axial Piston Fixed Motor A2FM Axial Piston Fixed Motor A2FM RE 91001/06.2012 1/46 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 5 315/350 bar 10 to 200 400/450 bar 250 to 1000 350/400 bar Open and closed

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HM(HD)B 270 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3

More information

High Torque Low Speed Motors MR - MRE

High Torque Low Speed Motors MR - MRE High Torque Low Speed Motors MR - MRE Calzoni Radial Piston Technology aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007 Design 45 Variable Displacement February 2007 Introduction With thru drive for single and multiple pumps Swash plate type for open circuit Technical Features Low noise level Fast response (eg. PV046: upstroke

More information

HPVR-10 AXIAL PISTON PUMPS

HPVR-10 AXIAL PISTON PUMPS The HPVR series of inline axial piston variable displacement pumps, are available in five displacements and three compact frame sizes. These pumps feature medium-high working pressure capabilities that

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES HY-TRANS THE PRODUCTION LINE OF HANSA-TMP Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

Low Speed High Torque Motors

Low Speed High Torque Motors Low Speed High Torque Motors Catalogue HY29-0503/UK TABLE OF CONTENTS Table of contents Features General information Functional description Technical data 3 4 4 5 6 FRAME SIZE P Operating diagrams Overall

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement Hydraulic Motor/Pump Series F11/F12 Fixed Displacement Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5 psi 1 l...0.264

More information

Series 20 Axial Piston Motors. Technical Information

Series 20 Axial Piston Motors. Technical Information Series 20 xial Piston Motors Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston motors. DESCRIPTION Sauer-Danfoss

More information

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives RE 91485 Edition: 10.2016 Replaces: 06.2011 For variable-speed operation with synchronous and asynchronous motors

More information

HPV-15 AXIAL PISTON PUMPS

HPV-15 AXIAL PISTON PUMPS SPECIFICATIONS Variable Displacement, Pressure Compensated OVERALL EFFICIENCY EFFICIENCY - % 100 90 80 70 60 bar 0 34 69 103 138 172 207 241 TYPICAL PERFORMANCE SPECIFICATIONS VOLUMETRIC cu. in./rev. 2.09

More information

Variable displacement axial piston pumps

Variable displacement axial piston pumps Variable displacement axial piston pumps SVP series GENERAL INFORMATIONS Variable displacement axial piston pump swash plate design for open circuit-flow sharing control valve. The pump has been designed

More information

Axial Piston Variable Pump A18VLO

Axial Piston Variable Pump A18VLO Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics ervice Axial Piston Variable Pump A18VLO RE 92280/06.09 1/12 Replaces: 02.09 Data sheet eries 10 ize NG80 Nominal

More information

1. Axial Piston Pumps

1. Axial Piston Pumps Axial Piston Pumps 1. Axial Piston Pumps Series Model Maximum Operating Pressure Maximum Displacement Remarks Page PSI In 3 /rev PV & PVM & PVR Premier Worldcup Goldcup PV6 4500 0.88 PV10 4500 1.26 PV15

More information

Axial Piston Variable Pump A1VO Series 10

Axial Piston Variable Pump A1VO Series 10 Features Axial Piston Variable Pump A1VO eries 10 Variable pump in axial piston swashplate design for hydrostatic drives in an open circuit The flow is proportional to the drive speed and displacement.

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs Gear Pumps Series PGP Fixed Displacement Pumps, Cast-Iron Designs aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Table

More information

Vane pumps, direct controlled Type PV7...A

Vane pumps, direct controlled Type PV7...A Vane pumps, direct controlled Type PV7...A Nominal sizes 1 to 25 eries 1X Maximum operating pressure 1 bar Displacements from 1 to 25 cm 3 H/A 617/95 Type PV7-1X/..RA1MA-... H/A/D 56/97 Typ MPU1-V71-9L/...

More information

Fixed displacement radial piston pump

Fixed displacement radial piston pump Fixed displacement radial piston pump RE 11263/05.13 Replaces: 10.05 1/16 Type R4 izes 1.60 to 20.00 cm 3 Component series 3X Maximum operating pressure 700 bar H7322 2R4-3X/4,00-700RK01M01+AZF8 H7321

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

Axial piston variable pump A10VO series 52 and 53

Axial piston variable pump A10VO series 52 and 53 Axial piston variable pump A10VO series 52 and 53 RE 92703 Edition: 10.2014 Replaces: 08.2011 izes 10 to 100 Nominal pressure 250 bar Maximum pressure 315 bar Open circuit A10VO 63DR/53... Features Variable

More information