Axial piston variable pump A10VSO Series 31

Size: px
Start display at page:

Download "Axial piston variable pump A10VSO Series 31"

Transcription

1 Axial piston variable pump A10VO eries 31 RE Edition: Replaces: All-purpose medium pressure pump izes 18 to 140 Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Features Variable pump with axial piston rotary group in swashplate design for hydrostatic drives in open circuit. The flow is proportional to the drive speed and displacement. The flow can be infinitely varied by adjusting the swashplate angle. 2 drain ports Excellent suction performance ow noise level ong service life Favorable power/weight ratio Versatile controller range hort control time The through drive is suitable for adding gear pumps and axial piston pumps up to the same size, i.e., 100% through drive. uitable for operation with mineral oil and HF hydraulic fluids Contents Type code 2 Hydraulic fluids 4 Working pressure range 6 Technical data, standard unit 7 Technical data, high-speed version 8 Technical data, HF hydraulic fluids 8 DG Two-point control, direct operated 10 DR Pressure controller 11 DRG Pressure controller, remote controlled 12 DFR/DFR1 Pressure flow controller 13 DFR Pressure, flow and power control 15 ED Electrohydraulic pressure control 16 ER Electrohydraulic pressure control 17 Dimensions, size 18 up to Dimensions, through drive 36 Overview of mounting options 42 Combination pumps A10VO + A10VO 43 Connector for solenoids 44 Installation instructions 45 Project planning notes 48 afety instructions 48 RE 92711/ , osch Rexroth AG

2 2 A10VO eries 31 Axial piston variable pump Type code Type code A10V O / 31 V Version tandard version (without code) HFA, HF, HFC hydraulic fluid (except for kydrol) E High-speed version (external dimensions are not affected by this option). H Axial piston unit 02 washplate design, variable, nominal pressure 280 bar, maximum pressure 350 bar A10V Operating mode 03 Pump, open circuit O ize (NG) 04 Geometric displacement, (see table of values on pages 6 and 7) Control device 05 Two-point control, direct operated DG Pressure controller hydraulic DR with flow controller hydraulic -T open DFR -T plugged with flushing function DFR1 with pressure cut-off hydraulic remote controlled DRG electrical negative control U = 12 V ED71 U = 24 V ED72 electrical positive control U = 12 V ER71 U = 24 V ER72 Pressure,flow and power controller DFR eries 06 eries 3, index 1 31 Direction of rotation 07 Viewed on drive shaft clockwise R counter-clockwise ealing material 08 FKM (fluoroelastomer) V NR (nitrile rubber) only if using HFA, HF and HFC hydraulic fluids (position 01; order code E ) P Drive shaft 09 plined shaft ANI 92.1a Parallel keyed shaft DIN 6885 standard shaft similar to shaft however for higher input torque R permissible through-drive torque (see page 9) P Mounting flange IO hole A 4-hole Working port 11 AE flange port fastening thread, metric at side, opposite osch Rexroth AG, RE 92711/

3 Axial piston variable pump A10VO eries 31 Type code A10V O / 31 V Through drive (for mounting options, see page 42) 12 Flange IO Hub for splined shaft 1) Diameter Diameter without through drive N (A) 5/8 in 9T 16/32DP K01 3/4 in 11T 16/32DP K () 7/8 in 13T 16/32DP K68 1 in 15T 16/32DP K (C) 1 1/4 in 14T 12/24DP K07 1 1/2 in 17T 12/24DP K (D) 1 3/4 in 13T 8/16DP K17 63, metric 4-hole haft key 25 K57 Flange IO Diameter 80, 2-hole 3/4 in 11T 16/32DP K2 100, 2-hole 7/8 in 13T 16/32DP K3 1 in 15T 16/32DP K4 125, 2-hole 1 1/4 in 14T 12/24DP K5 1 1/2 in 17T 12/24DP K6 180, 4-hole 1 3/4 in 13T 8/16DP K7 Connectors for solenoids 2) 13 Without connector (without solenoid, with hydraulic control only, without code) HIRCHMANN connector without suppressor diode H = Available = On request = Not available Notice Note the project planning notes on page 48. In addition to the type code, please specify the relevant technical data when placing your order. 1) Hub for splined shaft according to ANI 92.1a 2) Connectors for other electric components can deviate. RE 92711/ , osch Rexroth AG

4 4 A10VO eries 31 Axial piston variable pump Hydraulic fluids Hydraulic fluids The A10VO variable pump is designed for operation with HP mineral oil according to DIN Application instructions and requirements for hydraulic fluids should be taken from the following data sheets before the start project planning: 90220: Hydraulic fluids based on mineral oils and related hydrocarbons 90221: Environmentally acceptable hydraulic fluids 90222: Fire-resistant, water-free hydraulic fluids (HFDR/HFDU) (for permissible technical data, see data sheet 90255) 90223: Fire-resistant, water-containing hydraulic fluids (HFAE, HFA, HF, HFC) 90225: Restricted technical data only for operation with fire-resistant, water-free and water-containing hydraulic fluids (HFDR, HFDU, HF, HFC)- technical data Viscosity and temperature of hydraulic fluids Notes on selection of hydraulic fluid The hydraulic fluid should be selected so that the operating viscosity in the operating temperature range is within the optimum range (ν opt see selection diagram). Notice The axial piston unit is suitable for operation with watercontaining HF hydraulic fluid. ee version E Viscosity haft seal Temperature 3) Comment Cold start ν max 1600 mm²/s NR 2) θ t 40 C t 3 min, without load (p 50 bar), n 1000 min -1 FKM θ t -25 C Permissible temperature difference between axial piston unit and hydraulic fluid in the system maximum 25 K Warm-up phase ν = mm²/s t 15 min, p 0.7 p nom and n 0.5 n nom Continuous ν = mm²/s 1) NR 2) θ = +85 C measured at port, 1 operation FKM θ = +110 C ν opt = mm²/s Range of optimum operating viscosity and efficiency hort-term ν min = 10 7 mm²/s NR 2) θ = +85 C t 3 min, p 0.3 p nom, measured at port, 1 operation FKM θ = +110 C election diagram Maximum permissible viscosity for cold start Warm-up phase VG 22 VG 32 VG 68 VG 46 VG 100 Continuous operation ν opt Viscosity v [mm 2 /s] Minimum permissible viscosity for short-term operation Temperature θ [ C] 1) Corresponds e.g. for VG 46 to a temperature range of +4 C to +85 C (see selection diagram) 2) Version EA10VO...-P (if operating with HFA, HF and HFC hydraulic fluids 3) If the temperature at extreme operating parameters cannot be adhered to, please contact us. osch Rexroth AG, RE 92711/

5 Axial piston variable pump A10VO eries 31 Hydraulic fluids 5 Filtration of the hydraulic fluid Finer filtration improves the cleanliness level of the hydraulic fluid, which increases the service life of the axial piston unit. A cleanliness level of at least 20/18/15 is to be maintained according to IO At very high hydraulic fluid temperatures (maximum 110 C, measured at port, 1 ), at least a cleanliness level of 19/17/14 according to IO 4406 is necessary. Please contact us if the above classes cannot be observed. RE 92711/ , osch Rexroth AG

6 6 A10VO eries 31 Axial piston variable pump Working pressure range Working pressure range Pressure at working port Definition Nominal pressure p nom 280 bar The nominal pressure corresponds to the maximum design pressure. Maximum pressure p max 350 bar The maximum pressure corresponds to the maximum working pressure within the ingle operating period 2 ms single operating period. The sum of the single operating periods must not exceed Total operating period 300 h the total operating period. Minimum pressure p abs (high-pressure side) 10 bar 1) Minimum pressure on the high-pressure side () which is required in order to prevent damage to the axial piston unit. Rate of pressure change R A max bar/s Maximum permissible speed of pressure build-up and reduction during a pressure change across the entire pressure range. Pressure at suction port (inlet) Minimum pressure tandard 0.8 bar absolute Minimum pressure at suction port (inlet) that is required in order to avoid damage p min to the axial piston unit. The minimum pressure depends on the rotational speed and displacement of the axial piston unit. Maximum pressure p max 10 bar Case pressure at port, 1 Maximum pressure p max 2 bar 1) absolute Maximum 0.5 bar higher than inlet pressure at port, but not higher than p max. A case drain line to the reservoir is required. Rate of pressure change R A max Pressure p p nom p t Time t Notice Working pressure range valid when using hydraulic fluids based on mineral oils. Please contact us for values for other hydraulic fluids. Minimum permissible inlet pressure at suction port with speed increase In order to avoid damage to the pump (cavitation), a minimum inlet pressure must be guaranteed at suction port. The minimum inlet pressure level depends on the rotational speed and the displacement of the variable pump. Pressure definition 1.2 Pressure p ingle operating period t 1 t 2 t n Maximum pressure p max Nominal pressure p nom Minimum pressure (high-pressure side) Rotational speed n/nnom Displacement V g /V g max High speed version tandard version Inlet pressure p abs [bar] Time t Total operating period = t 1 + t t n 1) Other values on request During continuous operation in overspeed over n nom, a reduction in operational service life is to be expected due to cavitation erosion. osch Rexroth AG, RE 92711/

7 Axial piston variable pump A10VO eries 31 Technical data, standard unit 7 Technical data, standard unit ize NG Displacement, geometric, V g max cm per revolution Rotational speed at V g max n nom rpm maximum 1) 2) at V g <V g max rpm n max perm Flow at n nom and V g max q v max l/min at n E = 1500 rpm and V g max q ve max l/min Power at n nom, V g max P max kw at Δp = 280 bar at n E = 1500 rpm and V g max P E max kw Torque Δp = 280 bar T max Nm at V g max and Δp = 100 bar T Nm Rotary stiffness c Nm/rad of drive shaft R c Nm/rad P c Nm/rad Moment of inertia for rotary group J TW kgm Case volume V l Weight without through drive (approx.) m kg Weight with through drive (approx.) Determining the characteristics Flow q v = Torque T = Power P = Key V g n η v 1000 V g Δp 20 π η mh 2 π T n q v Δp = η t V g Displacement per revolution [cm 3 ] Δp Differential pressure [bar] n Rotational speed [rpm] η v Volumetric efficiency η hm Hydraulic-mechanical efficiency η t Total efficiency (η t = η v η hm ) [l/min] [Nm] [kw] Notice Theoretical values, without efficiency and tolerances; values rounded Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit. osch Rexroth recommends checking the load by means of test or calculation / simulation and comparison with the permissible values. 1) The values are applicable: For the optimum viscosity range from ν opt = 36 to 16 mm 2 /s For hydraulic fluid based on mineral oils For absolute pressure p abs = 1 bar at suction port 2) For a speed increase up to n max perm, please observe the diagram on page 6. RE 92711/ , osch Rexroth AG

8 8 A10VO eries 31 Axial piston variable pump Technical data, high-speed version (external dimensions are the same as the standard version) Technical data, high-speed version (external dimensions are the same as the standard version) ize NG Displacement, geometric, V g max cm per revolution Rotational speed at V g max n nom rpm maximum 1) 2) at V g <V g max rpm n max perm Flow at n nom and V g max q v max l/min Power at n nom, V g max and Δp = 280 bar P max kw Torque Δp = 280 bar T max Nm at V g max and Δp = 100 bar T Nm Rotary stiffness c Nm/rad drive shaft R c Nm/rad P c Nm/rad Moment of inertia for rotary group J TW kgm Case volume V l Weight without through drive (approx.) m kg Weight with through drive (approx.) Notice Theoretical values, without efficiency and tolerances; values rounded Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit. osch Rexroth recommends checking the load by means of test or calculation / simulation and comparison with the permissible values. Technical data, HF hydraulic fluids, maximum rotational speed Hydraulic fluid 3) E-version ize NG HFA at nominal pressure p N 140 bar at maximum pressure p max 160 bar n nom rpm HF at nominal pressure p N 140 bar at maximum pressure p max 160 bar n nom rpm HFC at nominal pressure p N 175 bar at maximum pressure p max 210 bar n nom rpm Technical data, HFD hydraulic fluids HFDR, HFDU polyalkylene at nominal pressure p N 280 bar glycol n nom rpm HFDU polyol ester at nominal pressure p N 280 bar ) The values are applicable: At absolute pressure p abs = 1 bar at suction port For the optimal viscosity range of ν opt = 36 to 16 mm 2 /s For hydraulic fluid based on mineral oils 2) For a speed increase up to n max perm, please observe the diagram on page 6. 3) For further information on HF hydraulic fluids, please see data sheets and osch Rexroth AG, RE 92711/

9 Axial piston variable pump A10VO eries 31 Technical data, high-speed version (external dimensions are the same as the standard version) 9 Permissible radial and axial forces of the drive shafts ize NG F q Maximum radial force at a/2 F q max N a/2 a/2 a Maximum axial force F ax + ± F ax max N Notice The values given are maximum values and do not apply to continuous operation. Drives with radial loading (pinion, V-belt drives) are not permissible! Permissible input and through-drive torques ize Torque at V g max and Δp = 280 bar 1) T max Nm Maximum input torque at drive shaft 2) T E max Nm Ø in 3 /4 7 / /4 1 1/4 1 1/2 1 3/4 R T E max Nm Ø in 3 /4 7 / /4 1 1/4 P T E max Nm Ø in Maximum through-drive torque T D max Nm R T D max Nm P T D max Nm Distribution of torques T1 T2 TE 1st pump 2nd pump T3 TD Torque at 1st pump T 1 Torque at 2nd pump T 2 Torque at 3rd pump T 3 Input torque T E = T 1 + T 2 + T 3 T E < T E max Through-drive torque T D = T 2 + T 3 T D < T D max 1) Efficiency not considered 2) For drive shafts with no radial force RE 92711/ , osch Rexroth AG

10 10 A10VO eries 31 Axial piston variable pump DG Two-point control, direct operated DG Two-point control, direct operated The variable pump can be set to a minimum swivel angle by Circuit diagram connecting an external switching pressure to port. This will supply control fluid directly to the stroking piston; M H 1) a minimum control pressure of p st 50 bar is required. The variable pump can only be switched between V g max or V g min. Please note that the required control pressure at port is directly dependent on the actual working pressure p in port. (ee control pressure characteristic curve). The maximum permissible switching pressure is 280 bar. witching pressure p st in = 0 bar witching pressure p st in 50 bar V g max V g min witching pressure characteristic curve Rec. switching pressure pst [bar] working pressure p [bar] 1 1) Only size 140 osch Rexroth AG, RE 92711/

11 Axial piston variable pump A10VO eries 31 DR Pressure controller 11 DR Pressure controller The pressure controller limits the maximum pressure at the pump outlet within the control range of the variable pump. The variable pump only supplies as much hydraulic fluid as is required by the consumers. If the working pressure exceeds the pressure command value at the pressure valve, the pump will regulate to a smaller displacement to reduce the control differential. Circuit diagram, sizes 18 to 100 Initial position in depressurized state: V g max. etting range 1) for infinitely variable 20 to 280 bar pressure control. tandard is 280 bar. Characteristic curve 280 Working pressure p [bar] Hysteresis/pressure rise Δp max 1 Circuit diagram, size Controller data q v min Flow q V q v max Characteristic curve valid at n 1 = 1500 rpm and θ fluid = 50 C. NG Pressure increase Δp [bar] Hysteresis and Δp [bar] maximum 3 repeatability Pilot fluid consumption [l/min] maximum approx. 3 1) In order to prevent damage to the pump and the system, the permissible setting range must not be exceeded. The range of possible settings at the valve is higher. RE 92711/ , osch Rexroth AG

12 12 A10VO eries 31 Axial piston variable pump DRG Pressure controller, remote controlled DRG Pressure controller, remote controlled For the remote controlled pressure controller, the pressure limitation is performed using a separately arranged pressure relief valve. Therefore any pressure control value under the pressure set on the pressure controller can be regulated. Pressure controller DR see page 11. A pressure relief valve is externally piped up to port for remote control. This relief valve is not included in the scope of delivery of the DRG control. When there is differential pressure of 20 bar Δp (standard setting), the quantity of control fluid at the port is approx. 1.5 l/min. If a different setting (range 10 to 22 bar) is required, please state in plain text. As a separate pressure relief valve (1) we recommend: a direct operated, hydraulic or electric proportional one, suitable for the control fluid mentioned above. The max. length of piping should not exceed 2 m. asic position in depressurized state:v g max. etting range 1) for pressure control 20 to 280 bar (3). tandard is 280 bar. etting range for differential pressure bar(2) tandard is 20 bar. Unloading port to the reservoir results in a zero stroke (standby) pressure which is approx. 1 to 2 bar higher than the defined differential pressure p, however system influences are not taken into account. Characteristic curve DRG Working pressure p [bar] 280 Hysteresis/pressure rise Δp max Circuit diagram DRG nominal size 18 to The separate pressure relief valve and the line are not included in the scope of delivery. 2 Remote controlled pressure cut-off (G). 3 Pressure controller (DR) Circuit diagram, size tand by 2) q v min Flow q V q v max Characteristic curve valid for n 1 = 1500 rpm and t fluid = 50 C. 1) In order to prevent damage to the pump and the system, the permissible setting range must not be exceeded. The range of possible settings at the valve is higher. 2) Zero stroke pressure from pressure setting p on controller (2) Controller data DRG NG Hysteresis and Δp [bar] maximum 4 repeatability Pilot fluid consumption [l/min] maximum approx. 4.5 osch Rexroth AG, RE 92711/

13 Axial piston variable pump A10VO eries 31 DFR/DFR1 Pressure flow controller 13 DFR/DFR1 Pressure flow controller In addition to the pressure controller function (see Circuit diagram DFR size 18 to 100 page 11), a variable orifice (e.g. directional valve) is used to adjust the differential pressure upstream and down- With DFR1 plugged stream of the orifice. This is used to control the pump flow. The pump flow is equal to the actual hydraulic fluid quantity required by the consumer. With all controller combinations, the V g reduction has priority. 2 1 asic position in depressurized state:v g max. etting range 1) to 280 bar. 3 For pressure controller data see page 11 Notice The DFR1 version has no unloading between and the reservoir. Unloading the -pilot line must be possible in the valve system. ecause of the flushing function of the flow controller in the DR control valve, sufficient unloading of the -line must also be provided. Characteristic curve Working pressure p [bar] 280 Hysteresis/pressure rise Δp max 1 Circuit diagram, size 140 With DFR1 plugged tand by 2) q v min Flow q V Characteristic curve at variable rotational speed q v max 3 Flow qv q V max q V min n 0 Rotational speed n n max Characteristic curve valid at n 1 = 1500 rpm and θ fluid = 50 C. Hysteresis / pressure increase ΔqVmax 1 The metering orifice (control block) and the line is not included in the scope of delivery. 2 Pressure and flow controller (FR). 3 Pressure controller (DR) For further information see page 14 1) In order to prevent damage to the pump and the system, the permissible setting range must not be exceeded. The range of possible settings at the valve is higher. 2) Zero stroke pressure from pressure setting p on controller (2) RE 92711/ , osch Rexroth AG

14 14 A10VO eries 31 Axial piston variable pump DFR/DFR1 Pressure flow controller Differential pressure p: tandard setting: 14 bar If another setting is required, please state in plain text. etting range: 14 bar to 22 bar Relieving the load on port to the reservoir results in a zero stroke ( standby ) pressure which lies about 1 to 2 bar higher than the defined differential pressure Δp, however, system influences are not taken into account. Controller data DR pressure controller data see page 11. Maximum flow deviation measured at drive speed n = 1500 rpm. NG Flow deviation Δq V max [l/min] Hysteresis and repeatability Δp [bar] maximum 4 Pilot fluid consumption [l/min] maximum approx. 3 to 4.5 (DFR) maximum approx. 3 (DFR1) osch Rexroth AG, RE 92711/

15 Axial piston variable pump A10VO eries 31 DFR Pressure, flow and power control 15 DFR Pressure, flow and power control Pressure controller equipped like DR, see page 11. Circuit diagram, sizes 28 to 100 Equipment of the flow controller like DFR1, see page 13 In order to achieve a constant drive torque with varying working pressures, the swivel angle and with it the output flow from the axial piston pump is varied so that the product of flow and pressure remains constant. Flow control is possible below the power control curve. 1 Characteristic curve and torque characteristic Maximum power curve Working pressure p [bar] Maximum power curve 1 0 Circuit diagram, size 140 qv (see table page 14) 1 Torque T 0 Flow q V [%] 100 Please contact us regarding beginning of control at < 50 bar When ordering please state the power characteristics to be set at the factory in plain text, e.g. 20 kw at 1500 rpm. 1 1 The metering orifice (control block) and the line is not included in the scope of delivery. Controller data For technical data of pressure controller DR see page 11. For technical data of flow controller FR see page 14. Control fluid consumption approx. 5.5 l/min max. RE 92711/ , osch Rexroth AG

16 16 A10VO eries 31 Axial piston variable pump ED Electrohydraulic pressure control ED Electrohydraulic pressure control The ED valve is set to a certain pressure by a specified variable solenoid current. With changes on the consumer (load pressure), this causes an increase or decrease in the pump swivel angle (flow) in order to maintain the electrically set pressure level. The pump thus only delivers as much hydraulic fluid as the consumers can take. The desired pressure level can be set steplessly by varying the solenoid current. As the solenoid current signal drops towards zero, the pressure will be limited to p max by an adjustable hydraulic pressure cut-off (secure fail safe function in case of power failure, e.g. for fan speed control). The swivel time characteristic of the ED control was optimized for the use as a fan drive system. When ordering, specify the type of application in plain text. Influence of the pressure setting on standby (maximally energized) tandby [bar] Maximum pressure setting [bar] tatic current-pressure characteristic curve ED (negative characteristic curve measured with pump in zero stroke) Circuit diagram ED71/ED72 Working pressure [bar] 280 ED deactivation of control Maximum 140 adjustable control pressure Minimum adjustable control pressure 0 0 Current I/I max 1 Hysteresis static current-pressure characteristic curve < 3 bar. Flow-pressure characteristic curve Maximum working pressure p [bar] (deenergized) 280 etting range 140 q v min Flow q V q v max Characteristic curves valid at n 1 = 1500 rpm and t fluid = 50 C. Control fluid consumption: 3 to 4.5 l/min. For standby standard setting, see diagram on right, other values on request. Hysteresis/pressure rise Δp max < 4 bar 1 Technical data, solenoid ED71 ED72 Voltage 12 V (±20%) 24 V (±20%) Control current tart of control at p max 0 ma 0 ma tart of control at p min 1200 ma 600 ma Current limit 1.54 A 0.77 A Nominal resistance (at 20 C) 5.5 Ω 22.7 Ω Dither frequency 100 to 200 Hz 100 to 200 Hz Duty cycle 100% 100% Electronic controls and type of protection, see page 44 Operating temperature range at valve -20 C to +115 C osch Rexroth AG, RE 92711/

17 Axial piston variable pump A10VO eries 31 ER Electrohydraulic pressure control 17 ER Electrohydraulic pressure control The ER valve is set to a certain pressure by a specified variable solenoid current. When changing the consumer (load pressure), this causes an increase or decrease in the pump swivel angle (flow) in order to maintain the electrically set pressure level. The pump thus only delivers as much hydraulic fluid as the consumers can take. The desired pressure level can be set steplessly by varying the solenoid current. If the solenoid current goes to zero, the pressure is limited to p min (standby) by the adjustable, hydraulic pressure cut-off. Circuit diagram Observe project planning note. Current-pressure characteristic curve (positive characteristic curve measured with pump in zero stroke) Working pressure [bar] Maximum adjustable control pressure Minimum 50 adjustable control pressure Current I/I max Hysteresis static < 3 bar. Flow-pressure characteristic curve Maximum working pressure p [bar] (deenergized) 280 etting range 140 q v min Flow q V q v max Characteristic curve valid at n 1 = 1500 rpm and θ fluid = 50 C. Control fluid consumption: 3 to 4.5 l/min. tandby standard setting 14 bar. Other values on request. Influence of pressure setting on stand by ±2 bar Hysteresis/pressure rise Δp max < 4 bar 1 Technical data, solenoid ER71 ER72 Voltage 12 V (±20%) 24 V (±20%) Control current tart of control at p min 100 ma 50 ma End of control at p max 1200 ma 600 ma Current limit 1.54 A 0.77 A Nominal resistance (at 20 C) 5.5 Ω 22.7 Ω Dither frequency 100 to 200 Hz 100 to 200 Hz Duty cycle 100% 100% Electronic controls and type of protection, see page 44 Operating temperature range at valve -20 C to +115 C Project planning note! Excessive current levels (I > 1200 ma at 12 V or I > 600 ma at 24 V) to the ER solenoid can result in undesired pressure increases which can lead to pump or system damage. Therefore: Use I max current limiter solenoids. An intermediate plate pressure controller can be used to protect the pump in the event of overflow. An accessory kit with intermediate plate pressure controller can be ordered from osch Rexroth under part number R RE 92711/ , osch Rexroth AG

18 18 A10VO eries 31 Axial piston variable pump Dimensions, size 18 Dimensions [mm] Dimensions, size 18 DFR/DFR1 Pressure flow controller, hydraulic, clockwise rotation V 6.3 Flange IO max ø W Detail V Detail W 22.2 ø ø osch Rexroth AG, RE 92711/

19 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size plined shaft 3/4 in (AE J744) plined shaft 3/4 in (AE J744) 11T 16/32DP 1) R 11T 16/32DP 1)2) P A Parallel keyed shaft, DIN ) 4) 1/4-20UNC ) 4) 1/4-20UNC ø Key width Usable spline length Centering 5) R DIN Ports tandard ize 4) p max abs [bar] 6) tate 10) Working port (standard pressure series) AE J518 7) 3/4 in 350 O Fastening thread DIN 13 M10 1.5; 17 deep uction port (standard pressure series) Fastening thread AE J518 7) DIN 13 1 in M10 1.5; 17 deep 10 O Drain port DIN ) M16 1.5; 12 deep 2 O 9) 1 Drain port DIN ) M16 1.5; 12 deep 2 9) Pilot pressure port DIN 3852 M14 1.5; 12 deep 350 O Pilot pressure port with DG-control DIN IO 228 G1/4 in; 12 deep 350 O 1) Involute spline according to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) plines according to ANI 92.1a, spline runout is a deviation from standard. 3) Thread according to AME 1.1 4) For notes on tightening torques, see the instruction manual 5) Coupling axially secured, e.g. with a clamp coupling or radially mounted clamping screw 6) Depending on the application, momentary pressure peaks can occur. Keep this in mind when selecting measuring devices and fittings. 7) Metric fastening thread is a deviation from standard. 8) The countersink can be deeper than as specified in the standard. 9) Depending on the installation position, or 1 must be connected (also see installation instructions starting on page 45). 10) O = Must be connected (plugged when delivered) = Plugged (in normal operation) RE 92711/ , osch Rexroth AG

20 20 A10VO eries 31 Axial piston variable pump Dimensions, size 18 Dimensions [mm] DG Two-point control, direct operated DR Pressure controller 148 1) 3 G 1/4 in max DRG Pressure controller, remote controlled ED7., ER7. Electrohydraulic pressure control 121 1) 108 1) 40 max ) 1) To flange surface 2) ER7.: 161 mm if using an intermediate plate pressure controller osch Rexroth AG, RE 92711/

21 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size Dimensions, size 28 DFR/DFR1 Pressure flow controller, hydraulic, clockwise rotation Flange IO V Detail V 22.2 Detail W max W 30.2 RE 92711/ , osch Rexroth AG

22 22 A10VO eries 31 Axial piston variable pump Dimensions, size 28 Dimensions [mm] plined shaft 7/8 in (AE J744) plined shaft 7/8 in (AE J744) Parallel keyed shaft, DIN T 16/32DP 1) R 13T 16/32DP 1)2) P A ) 4) 1/4-20UNC /4-20UNC-2 3)4) ø22 M6 4)5) Key width Usable spline length Ports tandard ize 4) p max abs [bar] 6) tate 10) Working port (standard pressure series) Fastening thread AE J518 7) DIN 13 3/4 in M10 1.5; 17 deep 350 O uction port (standard pressure series) Fastening thread AE J518 7) DIN /4 in M10 1.5; 17 deep 10 O Drain port DIN ) M18 1.5; 12 deep 2 O 9) 1 Drain port DIN ) M18 1.5; 12 deep 2 9) Pilot pressure port DIN 3852 M14 1.5; 12 deep 350 O Pilot pressure port with DG-control DIN IO 228 G1/4 in; 12 deep 350 O 1) Involute spline according to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) plines according to ANI 92.1a, spline runout is a deviation from standard. 3) Thread according to AME 1.1 4) For notes on tightening torques, see the instruction manual 5) Thread according to DIN 13, center bore according to DIN ) Depending on the application, momentary pressure peaks can occur. Keep this in mind when selecting measuring devices and fittings. 7) Metric fastening thread is a deviation from standard. 8) The countersink can be deeper than as specified in the standard. 9) Depending on the installation position, or 1 must be connected (also see installation instructions starting on page 45). 10) O = Must be connected (plugged when delivered) = Plugged (in normal operation) osch Rexroth AG, RE 92711/

23 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size DG Two-point control, direct operated DFR Pressure, flow and power controller 158 1) 198 1) G 1/4 in 3 40 max DR Pressure controller DRG Pressure controller, remote controlled 118 1) max max ED7., ER7. Electrohydraulic pressure control 130 1) ) 1) To flange surface 2) ER7.: mm if using an intermediate plate pressure controller RE 92711/ , osch Rexroth AG

24 24 A10VO eries 31 Axial piston variable pump Dimensions, size 45 Dimensions [mm] Dimensions, size 45 DFR/DFR1 Pressure flow controller, hydraulic, clockwise rotation V Flange IO W Detail V Detail W ø40 90 max ø ø osch Rexroth AG, RE 92711/

25 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size plined shaft 1 in (AE J744) plined shaft 1 in (AE J744) Parallel keyed shaft, DIN T 16/32DP 1) R 15T 16/32DP 1)2) P A ) 4) 1/4-20UNC ) 4) 1/4-20UNC ø25 M8 4)5) Key width Usable spline length Ports tandard ize 4) p max abs [bar] 6) tate 10) Working port (standard pressure series) Fastening thread AE J518 7) DIN 13 1 in M10 1.5; 17 deep 350 O uction port (standard pressure series) Fastening thread AE J518 7) DIN /2 in M ; 20 deep 10 O Drain port DIN ) M22 1.5; 14 deep 2 O 9) 1 Drain port DIN ) M22 1.5; 14 deep 2 9) Pilot pressure port DIN 3852 M14 1.5; 12 deep 350 O Pilot pressure port with DG-control DIN IO 228 G1/4 in; 12 deep 350 O 1) Involute spline according to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) plines according to ANI 92.1a, spline runout is a deviation from standard. 3) Thread according to AME 1.1 4) For notes on tightening torques, see the instruction manual 5) Thread according to DIN 13, center bore according to DIN ) Depending on the application, momentary pressure peaks can occur. Keep this in mind when selecting measuring devices and fittings. 7) Metric fastening thread is a deviation from standard. 8) The countersink can be deeper than as specified in the standard. 9) Depending on the installation position, or 1 must be connected (also see installation instructions starting on page 45). 10) O = Must be connected (plugged when delivered) = Plugged (in normal operation) RE 92711/ , osch Rexroth AG

26 26 A10VO eries 31 Axial piston variable pump Dimensions, size 45 Dimensions [mm] DG Two-point control, direct operated DFR Pressure, flow and power controller 173 1) 213 1) G 1/4 in DR Pressure controller DRG Pressure controller, remote controlled 133 1) max max ED7., ER7. Electrohydraulic pressure control 146 1) ) 1) To flange surface 2) ER7.: mm if using an intermediate plate pressure controller osch Rexroth AG, RE 92711/

27 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions sizes 71 and Dimensions sizes 71 and 88 DFR/DFR1 Pressure flow controller, hydraulic, clockwise rotation Flange IO V W Detail V Detail W 77.8 ø ø max ø RE 92711/ , osch Rexroth AG

28 28 A10VO eries 31 Axial piston variable pump Dimensions sizes 71 and 88 Dimensions [mm] plined shaft 1 1/4 in (AE J744) plined shaft 1 1/4 in (AE J744) Parallel keyed shaft, DIN T 12/24DP 1) R 14T 12/24DP 1)2) P A ) 4) 5/16-18UNC ) 4) 5/16-18UNC ø32 M10 4)5) Key width Usable spline length Ports tandard ize 4) p max abs [bar] 6) tate 10) Working port (standard pressure series) Fastening thread AE J518 7) DIN 13 1 in M10 1.5; 17 deep 350 O uction port (standard pressure series) Fastening thread AE J518 7) DIN 13 2 in M ; 20 deep 10 O Drain port DIN ) M22 1.5; 14 deep 2 O 9) 1 Drain port DIN ) M22 1.5; 14 deep 2 9) Pilot pressure port DIN 3852 M14 1.5; 12 deep 350 O Pilot pressure port with DG-control DIN IO 228 G1/4 in; 12 deep 350 O 1) Involute spline according to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) plines according to ANI 92.1a, spline runout is a deviation from standard. 3) Thread according to AME 1.1 4) For notes on tightening torques, see the instruction manual 5) Thread according to DIN 13, center bore according to DIN ) Depending on the application, momentary pressure peaks can occur. Keep this in mind when selecting measuring devices and fittings. 7) Metric fastening thread is a deviation from standard. 8) The countersink can be deeper than as specified in the standard. 9) Depending on the installation position, or 1 must be connected (also see installation instructions starting on page 45). 10) O = Must be connected (plugged when delivered) = Plugged (in normal operation) osch Rexroth AG, RE 92711/

29 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions sizes 71 and DG Two-point control, direct operated DFR Pressure, flow and power controller 201 1) 242 1) 3 G 1/4in ø DR Pressure controller DRG Pressure controller, remote controlled 161 1) max max ED7., ER7. Electrohydraulic pressure control 173 1) ) 1) To flange surface 2) ER7.: 195 mm if using an intermediate plate pressure controller RE 92711/ , osch Rexroth AG

30 30 A10VO eries 31 Axial piston variable pump Dimensions, size 100 Dimensions [mm] Dimensions, size 100 DFR/DFR1 Pressure flow controller, hydraulic, clockwise rotation Flange IO ø V W Detail V Detail W ø max ø osch Rexroth AG, RE 92711/

31 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size plined shaft 1 1/2 in (AE J744) Parallel keyed shaft, DIN T 12/24DP 1) P A ) 4) 7/16-14UNC ø ø M12 4)5) Key width Ports tandard ize 4) p max abs [bar] 6) tate 10) Working port (high-pressure series) Fastening thread AE J518 7) DIN /4 in M14 2; 19 deep 350 O uction port (standard pressure series) Fastening thread AE J518 7) DIN /2 in M ; 17 deep 10 O Drain port DIN ) M27 2; 16 deep 2 O 9) 1 Drain port DIN ) M27 2; 16 deep 2 9) Pilot pressure port DIN 3852 M14 1.5; 12 deep 350 O Pilot pressure port with DG-control DIN IO 228 G1/4 in; 12 deep 350 O 1) Involute spline according to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) plines according to ANI 92.1a, spline runout is a deviation from standard. 3) Thread according to AME 1.1 4) For notes on tightening torques, see the instruction manual 5) Thread according to DIN 13, center bore according to DIN ) Depending on the application, momentary pressure peaks can occur. Keep this in mind when selecting measuring devices and fittings. 7) Metric fastening thread is a deviation from standard. 8) The countersink can be deeper than as specified in the standard. 9) Depending on the installation position, or 1 must be connected (also see installation instructions starting on page 45). 10) O = Must be connected (plugged when delivered) = Plugged (in normal operation) RE 92711/ , osch Rexroth AG

32 32 A10VO eries 31 Axial piston variable pump Dimensions, size 100 Dimensions [mm] DG Two-point control, direct operated DFR Pressure, flow and power controller 268 1) 308 1) G 1/4in DR Pressure controller DRG Pressure controller, remote controlled 228 1) max max ED7., ER7. Electrohydraulic pressure control 241 1) ) 1) To flange surface 2) ER7.: 200 mm if using an intermediate plate pressure controller osch Rexroth AG, RE 92711/

33 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size Dimensions, size 140 DFR/DFR1 Pressure flow controller, hydraulic, clockwise rotation, mounting flange D Flange IO V ø W 66.7 ø ø ø Detail V Detail W RE 92711/ , osch Rexroth AG

34 34 A10VO eries 31 Axial piston variable pump Dimensions, size 140 Dimensions [mm] plined shaft 1 3/4 in (AE J744) Parallel keyed shaft, DIN T 8/16DP 1) P A ) 4) 1/2-13UNC ø ø45 M16 4)5) Key width Ports tandard ize 4) p max abs [bar] 6) tate 10) Working port (high-pressure series) Fastening thread AE J518 7) DIN /4 in M14 2; 19 deep 350 O uction port (standard pressure series) Fastening thread AE J518 7) DIN /2 in M ; 17 deep 10 O Drain port DIN ) M27 2; 16 deep 2 O 9) 1 Drain port DIN ) M27 2; 16 deep 2 9) Pilot pressure port DIN 3852 M14 1.5; 12 deep 350 O Pilot pressure port with DG-control DIN 3852 M14 1.5; 12 deep 350 O M H High pressure measurement (only with control DG) DIN 3852 M14 1.5; 12 deep 350 1) Involute spline according to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) plines according to ANI 92.1a, spline runout is a deviation from standard. 3) Thread according to AME 1.1 4) For notes on tightening torques, see the instruction manual 5) Thread according to DIN 13, center bore according to DIN ) Depending on the application, momentary pressure peaks can occur. Keep this in mind when selecting measuring devices and fittings. 7) Metric fastening thread is a deviation from standard. 8) The countersink can be deeper than as specified in the standard. 9) Depending on the installation position, or 1 must be connected (also see installation instructions starting on page 45). 10) O = Must be connected (plugged when delivered) = Plugged (in normal operation) osch Rexroth AG, RE 92711/

35 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, size DG Two-point control, direct operated DFR Pressure, flow and power controller 268 1) 314 1) M H DR Pressure controller DRG Pressure controller, remote controlled 244 1)3) 292 1) ED7., ER7. Electrohydraulic pressure control 241 1) ) 1) To flange surface 2) ER7.: 214 mm if using an intermediate plate pressure controller 3) For RE 92711/ , osch Rexroth AG

36 36 A10VO eries 31 Axial piston variable pump Dimensions, through drive Dimensions [mm] Dimensions, through drive Flange IO (AE) Hub for splined shaft 1) Availability over sizes Code Diameter ymbol Diameter (A),, 5/8 in 9T 16/32DP K01 3/4 in 11T 16/32DP K52 = Available = Not available A 45 ection A- A3 A2 A 45 ection A- A3 10 ø106.5 ø ø106.5 ø A4 A4 A1 (to mounting flange) 10 A1 (to mounting flange) A2 K01 (AE J (A)) NG A1 A2 A3 A4 2) K52 NG A1 A2 A3 A4 2) (AE J (A-)) M10 1.5; 14.5 deep M10 1.5; 14.5 deep M10 1.5; 16 deep M10 1.5; 16 deep M10 1.5; 16 deep M10 1.5; 16 deep M10 1.5; 20 deep M10 1.5; 20 deep M10 1.5; 20 deep M10 1.5; 20 deep M10 1.5; 16 deep M10 1.5; 16 deep M10 1.5; 16 deep M10 1.5; 16 deep 1) According to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) Thread according to DIN 13, see instruction manual for maximum tightening torques. osch Rexroth AG, RE 92711/

37 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, through drive 37 Flange IO (AE) Hub for splined shaft 1) Availability over sizes Code Diameter ymbol Diameter (A),, 7/8 in 13T 16/32DP K68 1 in 15T 16/32DP K04 = Available = Not available ection A- ection A- Omitte d for NG 28 A 45 A3 10 A 45 A3 10 ø146 ø ø146 ø A4 Omitted for NG 28 A1 (to mounting flange) A2 A4 A1 (to mounting flange) A2 K68 (AE J ()) NG A1 A2 A3 A4 2) K04 NG A1 A2 A3 A4 2) (AE J (-)) M ) M ; 18 deep M ; 18 deep M ; 20 deep M ; 20 deep M ; 20 deep M ; 20 deep M ; 20 deep M ; 20 deep M ; 20 deep M ; 20 deep 1) According to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) Thread according to DIN 13, see instruction manual for maximum tightening torques. 3) Continuous RE 92711/ , osch Rexroth AG

38 38 A10VO eries 31 Axial piston variable pump Dimensions, through drive Dimensions [mm] Flange IO (AE) Hub for splined shaft 1) Availability over sizes Code Diameter ymbol Diameter (C), 1 1/4 in 14T 12/24DP K07 1 1/2 in 17T 12/24DP K24 = Available = Not available omitted for NG 71 A 45 ection A- A3 omitted for NG A 45 ection A- A3 13 ø181 ø ø181 ø A4 A1 (to mounting flange) A2 A4 A1 (to mounting flange) A2 K07 (AE J (C)) NG A1 A2 A3 A4 2) K24 NG A1 A2 A3 A4 2) (AE J (C-C)) M16 2 3) M16 2 3) M16 2 3) M16 2; 32 deep M16 2 3) M16 2; 24 deep 1) According to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) Thread according to DIN 13, see instruction manual for maximum tightening torques. 3) Continuous osch Rexroth AG, RE 92711/

39 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, through drive 39 Flange IO (AE) Hub for splined shaft 1) Availability over sizes Code Diameter ymbol Diameter (A) 1 3/4 in 13T 8/16DP K Metric keyed shaft 25 K57 = Available = Not available metric 4) A ection A- A3 13 A ection A- A4 A ø ø80 ø A A1 (to mounting flange) A2 ø A5 A1 (to mounting flange) A2 K17 (AE J (D)) NG A1 A2 A3 A4 2) K57 NG A1 A2 A3 A4 A5 5) (4-hole flange) M16 2; 3) M M M M M M8 1) According to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) Thread according to DIN 13, see instruction manual for maximum tightening torques. 3) Continuous 4) For mounting an R4 radial piston pump (see data sheet 11263) 5) crews for mounting the radial piston motor are included in the scope of delivery RE 92711/ , osch Rexroth AG

40 40 A10VO eries 31 Axial piston variable pump Dimensions, through drive Dimensions [mm] Flange IO Hub for splined shaft 1) Availability over sizes Code Diameter ymbol Diameter , 2-hole,, 3/4 in 11T 16/32DP K2 100, 2-hole 7/8 in 13T 16/32DP K3 1 in 15T 16/32DP K4 = Available = Not available 80, 2-hole 100, 2-hole Omitted for NG140 A 45 ection A- A3 10 A 45 ection A- A3 10 ø109 ø ø140 ø A4 A4 omitted for NG100 A1 (to mounting flange) A2 A1 (to mounting flange) A2 K2 (AE J (A-)) NG A1 A2 A3 A4 2) K3 NG A1 A2 A3 A4 2) (AE J ()) M10 1.5; 14.5 deep M ) M10 1.5; 16 deep M ) M10 1.5; 16 deep M12 1.5; 20 deep M10 1.5; 20 deep M12 1.5; 20 deep M10 1.5; 20 deep M12 1.5; 20 deep M10 1.5; 20 deep M12 1.5; 20 deep M10 1.5; 20 deep 100, 2-hole ection A- A 45 A3 10 ø140 ø A4 A1 (to mounting flange) A2 1) According to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) Thread according to DIN 13, see instruction manual for maximum tightening torques. 3) Continuous osch Rexroth AG, RE 92711/ K4 (AE J (-)) NG A1 A2 A3 A4 2) M ) M ; 20 deep M ; 20 deep M ; 20 deep M ; 20 deep

41 Dimensions [mm] Axial piston variable pump A10VO eries 31 Dimensions, through drive 41 Flange IO Hub for splined shaft 1) Availability over sizes Code Diameter ymbol Diameter , 2-hole, 1 1/4 in 14T 12/24DP K5 1 1/2 in 17T 12/24DP K6 180, 2-hole 1 3/4 in 13T 8/32DP K7 = Available = Not available 125, 2-hole 125, 2-hole ection A- ection A- Omitted for NG71 A 45 Omitted for NG71 A3 10 A ø ø ø180 ø A4 A1 (to mounting flange) A2 A4 A2 A1 (to mounting flange) K5 (AE J (C)) NG A1 A2 A3 A4 2) K6 (AE J (C-C)) NG A1 A2 A3 A4 2) M16 2 3) M16 2 3) M16 2 3) M16 2; 32 deep M16 2 3) M16 2; 24 deep 180, 4-hole A ection A- A ø A4 A A1 (to mounting flange) K7 (AE J (D)) NG A1 A2 A3 A4 2) M16 2 3) 1) According to ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5 2) Thread according to DIN 13, see instruction manual for maximum tightening torques. 3) Continuous RE 92711/ , osch Rexroth AG

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces:

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces: Axial piston variable pump (A)A10VO eries 31 Americas RE-A 92711 Edition: 04.2017 Replaces: 04.2012 All-purpose medium pressure pump izes 18 to 140 Nominal pressure 4100 psi (280 bar) Maximum pressure

More information

Axial piston variable pump A10V(S)O Series 31

Axial piston variable pump A10V(S)O Series 31 Axial piston variable pump A10V()O eries 31 RE 92701 Edition: 06.2016 Replaces: 01.2012 ize 18 (A10VO) izes 28 to 1 (A10VO) Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Features Variable

More information

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces: Axial piston variable pump A10V()O eries 31 Americas RE-A 92701 Edition: 02.2017 Replaces: 03.2012 ize 18 (A10VO) izes 28 to 140 (A10VO) Nominal pressure 4100 psi (280 bar) Maximum pressure 5100 psi (350

More information

Axial piston variable pump A10VO Series 32

Axial piston variable pump A10VO Series 32 Axial piston variable pump A10VO eries 32 RE 92705 Edition: 06.2016 Replaces: 01.2012 Optimized medium pressure pump for powerful machines izes 45 to 180 Nominal pressure 280 bar Maximum pressure 350 bar

More information

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces: Axial piston variable pump A10VO series 32 Americas RE-A 92714 Issue: 02.15 Replaces: 06.11 izes 45 to 180 Nominal pressure 4100 psi (280 bar) Maximum pressure 5100 psi (350 bar) For industrial application

More information

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A10VSO Axial Piston Variable Pump A10VO RE 92711/01.12 1/48 Replaces: 06.09 and RE 92707/11.10 Data sheet eries 31 izes 18 to 1 Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Contents Type code

More information

Axial piston variable pump A10VSO series 32

Axial piston variable pump A10VSO series 32 xial piston variable pump 10VO series 32 RE 92714 Issue: 10.2014 Replaces: 06.2011 izes 45 to 180 Nominal pressure 280 bar Maximum pressure 350 bar For industrial application areas Open circuit Characteristics

More information

Axial piston variable pump A10VO series 52 and 53

Axial piston variable pump A10VO series 52 and 53 Axial piston variable pump A10VO series 52 and 53 RE 92703 Edition: 12.2015 Replaces: 10.2014 izes 10 to 100 Nominal pressure 250 bar Maximum pressure 315 bar Open circuit A10VO 63DR/53... Features Variable

More information

Axial piston variable pump A10VO series 52 and 53. Americas. RE-A Edition: Replaces:

Axial piston variable pump A10VO series 52 and 53. Americas. RE-A Edition: Replaces: Axial piston variable pump A10VO series 52 and 53 Americas RE-A 92703 Edition: 12.2016 Replaces: 03.2015 izes 10 to 100 Nominal pressure 3600 psi (250 bar) Maximum pressure 4550 psi (315 bar) Open circuit

More information

Axial piston variable pump A10VO series 52 and 53

Axial piston variable pump A10VO series 52 and 53 Axial piston variable pump A10VO series 52 and 53 RE 92703 Edition: 10.2014 Replaces: 08.2011 izes 10 to 100 Nominal pressure 250 bar Maximum pressure 315 bar Open circuit A10VO 63DR/53... Features Variable

More information

Axial piston variable pump A10VO series 52 and 53

Axial piston variable pump A10VO series 52 and 53 Axial piston variable pump A10VO series 52 and 53 RE 92703 Edition: 12.2015 Replaces: 10.2014 izes 10 to 100 Nominal pressure 250 bar Maximum pressure 315 bar Open circuit A10VO 63DR/53... Features Variable

More information

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO Axial Piston Variable Pump A10VO RE 92705/01.12 1/44 Replaces: 06.09 Data sheet eries 32 izes 71 to 180 Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Contents Type code for standard program

More information

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A10VSO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RE 92714/06.11 1/44 Replaces: 07.10 and RE 92707 Data sheet eries 32 ize

More information

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40 Axial piston variable pump A4VG eries 40 RE 92004 Edition: 07.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit up to 500 bar ize 110...280 Nominal pressure 450 bar Maximum

More information

Axial piston variable pump. A10VNO series 53. RE Edition: Replaces:

Axial piston variable pump. A10VNO series 53. RE Edition: Replaces: Axial piston variable pump A10VNO series 52 and 53 RE 92735 Edition: 04.2015 Replaces: 03.2012 ize 28 to 85 Nominal pressure 210 bar Maximum pressure 250 bar open circuit A10VNO series 52 A10VNO series

More information

Axial Piston Variable Pump A10VO (US-Version)

Axial Piston Variable Pump A10VO (US-Version) Axial Piston Variable Pump A1VO (U-Version) RA-A 9273/12.11 1/6 Replaces: 11.7 RE 9278/3.8 and RE 9277/11.1 Data sheet eries 52/53 ize NG1 to 1 Nominal pressure 36 psi (25 bar) Peak pressure 46 psi (315

More information

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40 Axial piston variable pump A4VG eries 40 RE 92004 Edition: 09.2017 Replaces: 02.2017 High-pressure pump for applications in a closed circuit up to 500 bar ize 110 280 Nominal pressure 450 bar Maximum pressure

More information

Axial piston variable pump A10VSO Series 31 for explosive areas ATEX II 3G ck IIB T4

Axial piston variable pump A10VSO Series 31 for explosive areas ATEX II 3G ck IIB T4 Axial piston variable pump A10VSO Series 31 for explosive areas ATE II 3G ck II T4 Part II of instruction manual according to ATE directive 94/9/EC data sheet RE 92711-01--2 Issue: 04.2015 Replaces:. Sizes

More information

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40 Axial piston variable pump A4VG eries 40 RE 92004 Edition: 02.2017 Replaces: 07.2016 High-pressure pump for applications in a closed circuit up to 500 bar ize 110...280 Nominal pressure 450 bar Maximum

More information

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives RE 91485 Edition: 10.2016 Replaces: 06.2011 For variable-speed operation with synchronous and asynchronous motors

More information

Axial piston variable pump. A10VNO series 53. Americas. RE-A Edition: Replaces:

Axial piston variable pump. A10VNO series 53. Americas. RE-A Edition: Replaces: Axial piston variable pump A10VNO series 52 and 53 Americas RE-A 92735 Edition: 24.04.2015 Replaces: 06.2012 ize 28 to 85 Nominal pressure 3050 psi (210 bar) Maximum pressure 3600 psi (250 bar) open circuit

More information

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces:

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces: Axial piston variable pump A4VG eries 40 Americas RE-A 92004 Edition: 09.2017 Replaces: 06.2012 High-pressure pump for applications in a closed circuit up to 7250 psi (500 bar) ize 110 280 Nominal pressure

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

Axial Piston Variable Pump A10VSNO

Axial Piston Variable Pump A10VSNO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VNO RE 92741/03.11 1/16 Data sheet eries 52 ize 15 Nominal pressure 210 bar

More information

Axial piston variable pump A1VO series 10

Axial piston variable pump A1VO series 10 Axial piston variable pump A1VO series 10 RE 92650 Edition: 09.2013 Replaces: 02.2013 izes 18, 35 Nominal pressure 250 bar Maximum pressure 280 bar Open circuit Features Variable axial piston pump of swashplate

More information

Axial Piston Variable Pump A1VO Series 10

Axial Piston Variable Pump A1VO Series 10 Features Axial Piston Variable Pump A1VO eries 10 Variable pump in axial piston swashplate design for hydrostatic drives in an open circuit The flow is proportional to the drive speed and displacement.

More information

Axial piston variable pump A1VO Series 10

Axial piston variable pump A1VO Series 10 Axial piston variable pump A1VO eries 10 RE 92650 Edition: 06.2016 Replaces: 08.2015 For load-sensing-systems in smaller working machines izes 18, 28, 35 Nominal pressure 250 bar Maximum pressure 280 bar

More information

Axial Piston Variable Pump A18VLO Series 11

Axial Piston Variable Pump A18VLO Series 11 Axial Piston Variable Pump A18VLO eries 11 RE 92280 Issue: 06.2012 Replaces: 06.2009 ize 80 Nominal pressure 350 bar Maximum pressure 400 bar For commercial vehicles Open circuit Features Variable pump

More information

Axial piston variable pump A11V(L)O series 40

Axial piston variable pump A11V(L)O series 40 xial piston variable pump 11V(L)O series 40 RE 92510 Issue: 10.2014 Replaces: 10.2013 izes 110 to 280 Nominal pressure 350 bar (5100 psi) Maximum pressure 420 bar (6100 psi) Open circuit Characteristics

More information

Axial Piston Variable Double Pump A8VO

Axial Piston Variable Double Pump A8VO Axial Piston Variable Double Pump A8VO RE 93010/03.09 1/40 Replaces: 11.07 Data sheet Series 61 / 63 Sizes 55...200 Nominal pressure 350 bar Peak pressure 400 bar for open circuit Contents Ordering Code

More information

Axial Piston Variable Pump A10VSNO

Axial Piston Variable Pump A10VSNO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VNO RE 92740/07.10 1/16 Data sheet eries 32 ize 63 Nominal pressure 210 bar

More information

Variable Axial Piston Pump A10V Series - 52/53

Variable Axial Piston Pump A10V Series - 52/53 Variable Axial Piston Pump A10V eries - 52/53 eries 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) izes 10cm 3 /rev - 63cm 3 /rev (0.64in 3 /rev-3.8in 3 /rev)

More information

Axial piston variable motor A6VM series 71

Axial piston variable motor A6VM series 71 xial piston variable motor 6VM series 71 RE 91610 Edition: 06.2014 Replaces: 04.2013 Sizes 60 to 215 Nominal pressure 450 bar Maximum pressure 500 bar Open and closed circuits Features Variable motor with

More information

Axial Piston Fixed Pump A2FO

Axial Piston Fixed Pump A2FO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Fixed Pump A2FO RE 91401/03.08 1/24 Replaces: 09.07 Technical data sheet eries 6 izes Nominal

More information

Axial piston variable motor A6VM Series 63. Europe. RE-E Edition: Replaces:

Axial piston variable motor A6VM Series 63. Europe. RE-E Edition: Replaces: xial piston variable motor 6V Series 63 Europe RE-E 91604 Edition: 05.2016 Replaces: 06.2012 ll-purpose high pressure motor Sizes 28: Nominal pressure 400 bar aximum pressure 450 bar Sizes 250 to 1000:

More information

Axial Piston Fixed Motor A2FM

Axial Piston Fixed Motor A2FM Axial Piston Fixed Motor A2FM RE 91001/06.2012 1/46 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 5 315/350 bar 10 to 200 400/450 bar 250 to 1000 350/400 bar Open and closed

More information

Axial Piston Fixed Pump A17FNO

Axial Piston Fixed Pump A17FNO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Fixed Pump A17FNO RE 91510/03.10 1/12 Data sheet eries 10 ize 125 Nominal pressure 250 bar

More information

Axial piston fixed pump AA2FO

Axial piston fixed pump AA2FO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial piston fixed pump AA2FO RA-A 91401/07.2014 1/32 Replaces: 03.08 Data sheet eries 6 izes Nominal pressure/maximum

More information

Axial piston fixed pump A17FO Series 10

Axial piston fixed pump A17FO Series 10 Axial piston fixed pump A17FO eries 10 E 91520 Issue: 11.2015 eplaces: 10.2014 High-pressure pump for use in commercial vehicles izes 23 to 107 Nominal pressure/maximum pressure 350/400 bar Bent-axis design

More information

Axial Piston Variable Pump A18VLO

Axial Piston Variable Pump A18VLO Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics ervice Axial Piston Variable Pump A18VLO RE 92280/06.09 1/12 Replaces: 02.09 Data sheet eries 10 ize NG80 Nominal

More information

Axial piston fixed pump A17FNO Series 10

Axial piston fixed pump A17FNO Series 10 Axial piston fixed pump A17FNO eries 10 E 91510 Issue: 11.2015 eplaces: 06.2012 Designed for use in commercial vehicles with standard pressure requirements ize 125 Nominal pressure/maximum pressure 250/300

More information

Axial piston variable pump A7VO

Axial piston variable pump A7VO Axial piston variable pump A7VO RE 92203/06.09 1/52 Replaces: 05.99 Data sheet Series 63 Sizes NG250 to 500 Nominal pressure 350 bar Peak pressure 400 bar Open circuit Contents Type code for Standard program

More information

2-Circuit Axial Piston Fixed Pump A18FDO

2-Circuit Axial Piston Fixed Pump A18FDO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice 2-Circuit Axial Piston Fixed Pump A18FDO E 91540/03.10 1/12 eplaces: 06.09 Data sheet eries 10 ize 63,

More information

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RA 92703/11.07 1/44 Replaces: 06.07 Data sheet eries 52/53 ize 10...85

More information

Axial piston variable pump A11V(L)O Series 40

Axial piston variable pump A11V(L)O Series 40 xial piston variable pump 11V(L)O eries 40 RE 92510 Edition: 05.2016 Replaces: 10.2014 izes 110 to 280 Nominal pressure 350 bar (5100 psi) Maximum pressure 420 bar (6100 psi) Open circuit Features Variable

More information

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Fixed Motor 2FNM for Fan Drives and Flywheel Mass RE 91007/02.11 1/16 Data sheet Series 61

More information

Axial Piston Variable Pump A4VTG

Axial Piston Variable Pump A4VTG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A4VTG RE 92013/04.08 1/20 Replaces: RE 92012 Data heet eries 33 izes NG71, 90

More information

Variable plug-in motor A6VE Series 71

Variable plug-in motor A6VE Series 71 Variable plug-in motor 6VE Series 71 RE 91616 Edition: 05.2016 Replaces: 08.2015 High pressure motor for integration in mechanical gearbox Sizes 60 to 215 Nominal pressure 450 bar Maximum pressure 500

More information

Axial piston variable motor A6VM series 65. Americas. RE-A Edition: Replaces:

Axial piston variable motor A6VM series 65. Americas. RE-A Edition: Replaces: xial piston variable motor 6VM series 65 mericas RE- 91607 Edition: 11.2015 Replaces: 01.2015 Sizes 55 to 200 Nominal pressure 5800 psi (400 bar) Maximum pressure 6500 psi (450 bar) Open and closed circuits

More information

ENGINEERING DATA. Variable Axial Piston Pump A10V Series - 52/53. w w w. F l u i D y n e F P. c o m E m a i l : F l u i D y n e F P.

ENGINEERING DATA. Variable Axial Piston Pump A10V Series - 52/53. w w w. F l u i D y n e F P. c o m E m a i l : F l u i D y n e F P. ENGINEERING DATA Variable Axial Piston Pump A10V eries - 52/53 eries 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) izes 10cm 3 /rev - 63cm 3 /rev (0.64in 3

More information

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version)

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version) xial piston variable pump 15VO, 15VLO series 10 (U-Version) R- 92800 Edition: 11.2013 Replaces:. izes 110 to 280 Nominal pressure 5100 psi (350 bar) Maximum pressure 6100 psi (420 bar) Open circuit Features

More information

Variable Plug-in Motor A6VE

Variable Plug-in Motor A6VE Variable Plug-in Motor 6VE RE 91616/01.12 1/52 Data sheet Series 71 Sizes 60 to 170 Nominal pressure 450 bar Maximum pressure 500 bar Open and closed circuits Contents Ordering code for standard program

More information

Axial Piston Variable Pump A18VO Series 11

Axial Piston Variable Pump A18VO Series 11 xial Piston Variable Pump 18VO eries 11 RE 92270 Issue: 06.2012 Replaces: 06.2009 izes 55 to 107 Nominal pressure 350 bar Maximum pressure 400 bar For commercial vehicles Open circuit Features Variable

More information

Axial piston variable motor A6VM series 71. Americas. RE-A Edition: Replaces:

Axial piston variable motor A6VM series 71. Americas. RE-A Edition: Replaces: xial piston variable motor 6VM series 71 mericas RE- 91610 Edition: 12.2015 Replaces: 04.2013 Sizes 60 to 215 Nominal pressure 6500 psi (450 bar) Maximum pressure 7250 psi (500 bar) Open and closed circuits

More information

Axial Piston Variable Pump A4VTG

Axial Piston Variable Pump A4VTG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A4VTG RE 92013/06.09 1/24 Replaces: 04.08 Data sheet eries 33 izes NG71, 90

More information

Axial piston fixed motor A2FM Series 70 A2FE Series 70

Axial piston fixed motor A2FM Series 70 A2FE Series 70 Axial piston fixed motor A2FM Series 70 A2FE Series 70 RE 91071 RE Edition: 910712.2015 Edition: Replaces 12.2015 03.2015 A2FMN, A2FEN (sizes 56 to 107): Nominal pressure 300 bar Maximum pressure 350 bar

More information

Axial Piston Fixed Pump A17FNO Series 10

Axial Piston Fixed Pump A17FNO Series 10 Axial Piston Fixed Pump A17FNO Series 10 RE 91510 Issue: 06.2012 Replaces: 03.2010 Size 125 Nominal pressure 250 bar Maximum pressure 300 bar For commercial vehicles Open circuit Features Fixed pump with

More information

Axial Piston Variable Pump A4VG

Axial Piston Variable Pump A4VG Axial Piston Variable Pump A4VG RE 92003/06.09 1/64 Replaces: 03.09 Data sheet Series 32 Sizes 28...250 Nominal 400 bar Peak 450 bar Closed circuit Contents Ordering Code / Standard Program 2 Technical

More information

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition: Axial piston fixed motor A2FM series 70 Americas RE-A 91071 Edition: 05.2015 A2FMN (Sizes 90 and 107): Nominal pressure 300 bar Maximum pressure 350 bar A2FMM (Sizes 80 and 90): Nominal pressure 400 bar

More information

Axial piston variable pump A4VSO for explosive areas ATEX II 3G c IIC T4

Axial piston variable pump A4VSO for explosive areas ATEX II 3G c IIC T4 Axial piston variable pump A4VSO for explosive areas ATEX II 3G c IIC T4 Part II of instruction manual according to ATEX directive 94/9/EC Data Sheet RE 92050-01-X-2 Edition: 04.2015 Replaces: 10.2014

More information

Axial piston variable pump (A)A4VSO

Axial piston variable pump (A)A4VSO Axial piston variable pump (A)A4VSO RA 92050-A/06.09 1/64 Replaces: 09.97 Data sheet Series 10, 11 and 30 Size 40...1000 Nominal pressure 5100 psi (350 bar) Peak pressure 5800 psi (400 bar) Open circuit

More information

Axial piston variable pump A4CSG Series 3x

Axial piston variable pump A4CSG Series 3x Axial piston variable pump A4CG eries 3x R 92105 dition: 12.2016 Replaces: 07.2016 izes 250 to 750 Nominal pressure 350 bar aximum pressure 400 bar Closed circuit Features Variable pump in axial piston

More information

Axial Piston Variable Motor A6VM

Axial Piston Variable Motor A6VM Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Variable Motor 6VM RE 91610/07.09 1/80 Replaces: 03.09 Data sheet Series 71 Sizes N60 to 280

More information

Axial Piston Variable Pump A15VSO

Axial Piston Variable Pump A15VSO Axial iston Variable ump A15VSO RE 928/5.12 1/4 Replaces: 3.1 Data sheet Series 1 Sizes 175 to 28 Nominal pressure 35 bar Maximum pressure 42 bar Open circuit Contents Ordering code for standard program

More information

Axial piston variable double pump A28VLO Series 10

Axial piston variable double pump A28VLO Series 10 Axial piston variable double pump A28VLO eries 10 RE 93110 Edition: 04.2016 Replaces: 12.2015 izes 280 Nominal pressure 350 bar Maximum pressure 420 bar Open circuit Features Variable axial piston double

More information

Axial Piston Variable Pump A4VG

Axial Piston Variable Pump A4VG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump A4VG RE 92003/03.09 1/64 Replaces: 09.07 Data sheet Series 32 Sizes 28...250

More information

Axial piston variable pump A4VSO for explosive areas ATEX II 3G ck IIC Tx

Axial piston variable pump A4VSO for explosive areas ATEX II 3G ck IIC Tx Axial piston variable pump A4VSO for explosive areas ATEX II 3G ck IIC Tx Part II of instruction manual according to ATEX directive 2014/34/EU Data Sheet RE 92050-01-X-2 Edition: 01.2017 Replaces: 04.2016

More information

Axial piston variable pump A18VO series 11

Axial piston variable pump A18VO series 11 xial piston variable pump 18VO series 11 E 92270 Edition: 06.2015 eplaces: 06.2012 High-pressure pump for use in commercial vehicles izes 55 to 107 Nominal pressure 350 bar Maximum pressure 400 bar Open

More information

Axial piston fixed motor A2FM for explosive areas II 2G ck IIB Tx

Axial piston fixed motor A2FM for explosive areas II 2G ck IIB Tx xial piston fixed motor 2FM for explosive areas II 2G ck II Tx Part II of instruction manual according to TEX directive 2014/34/EU data sheet RE 91001-01-X-2 Edition: 04.2016 Replaces: 01.2016 Series 61

More information

Axial Piston Variable Pump AA4VG

Axial Piston Variable Pump AA4VG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump AA4VG RA 92003-A/06.09 1/64 Replaces: 03.09 Data sheet Series 32 Size 28...

More information

Axial Piston Variable Pump A7VO

Axial Piston Variable Pump A7VO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A7VO E 92 202/03.06 1/32 eplaces: 07.95 Technical data sheet eries 6 izes 28...160

More information

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RA 92703/11.07 1/44 Replaces: 06.07 Data sheet eries 52/53 ize 10...85

More information

Axial Piston Variable Motor A6VM

Axial Piston Variable Motor A6VM xial Piston Variable Motor 6VM R- 91610/01.12 1/80 Data sheet Series 71 Sizes 60 to 280 Nominal pressure 6500 psi (450 bar) Maximum pressure 7250 psi (500 bar) Open and closed circuits Contents Ordering

More information

Axial Piston Variable Motor A6VM (US-Version)

Axial Piston Variable Motor A6VM (US-Version) xial Piston Variable Motor 6VM (US-Version) R- 91610/04.13 1/74 Replaces: 06.12 Data sheet Series 71 Sizes 60 to 215 Nominal pressure 6500 psi (450 bar) Maximum pressure 7250 psi (500 bar) Open and closed

More information

Axial Piston Variable Pump AA11VO

Axial Piston Variable Pump AA11VO Electric rives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics ervice xial Piston Variable Pump 11VO 92500-/10.09 1/68 eplaces: 06.09 ata sheet eries 1 ize N40 to 260 Nominal

More information

Axial Piston Variable Motor A6VM

Axial Piston Variable Motor A6VM Electric Drives and Controls Hydraulics Linear otion and ssembly Technologies Pneumatics Service xial Piston Variable otor 6V RE 91604/01.07 1/76 Replaces: 05.06 Technical data sheet Series 6 Sizes Nominal

More information

Axial Piston Fixed Motor A10FM / A10FE (US-Version)

Axial Piston Fixed Motor A10FM / A10FE (US-Version) xial Piston Fixed Motor 10FM / 10FE (US-Version) R- 91172/03.12 1/32 Replaces: 01.11 Data sheet Series 52 Sizes 10 to 63 Nominal pressure 4000 psi (280 bar) Maximum pressure 5100 psi (350 bar) Open and

More information

Variable Displacement Pumps

Variable Displacement Pumps variable displacement pumps variable displacement pumps Variable Displacement Pump Prices Seal Kits Prices Application & Features A10VSO Pumps Dimensions Technical Information Sec:2 Sec:2 Sec:3 Sec:4 Sec:8

More information

Fixed Displacement Pump A2FO

Fixed Displacement Pump A2FO RE 91401/01.97 Brueninghaus Hydromatik eries 6, for open circuits Axial tapered piston - bent axis design izes 5...1000 Nom. Pressure up to 400 bar Peak Pressure up to 4 bar RE 91401/01.97 replaces 11.95

More information

Fixed Displacement Motor A10FM A10FE

Fixed Displacement Motor A10FM A10FE Electric Drives and Controls Hydraulics inear Motion and ssembly Technologies Pneumatics Service Fixed Displacement Motor 10FM 10FE RE 91 172/06.06 1/24 Replaces: 01.03 Technical Data Sheet Size 10...63

More information

Fixed Plug-In Motor A2FE

Fixed Plug-In Motor A2FE Fixed Plug-In Motor 2FE RE 91008/06.2012 1/24 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 28 to 180 400/450 bar 250 to 355 350/400 bar Open and closed circuits Contents Ordering

More information

Axial piston variable motor AA6VM series 63. Americas. RE-A Edition: Replaces:

Axial piston variable motor AA6VM series 63. Americas. RE-A Edition: Replaces: Axial piston variable motor AA6V series 63 Americas RE-A 91604 Edition: 08.2016 Replaces: 03.2014 All-purpose high pressure motor Size 250 Nominal pressure 5100 psi (350 bar) aximum pressure 5800 psi (400

More information

Axial Piston Variable Motor AA6VM (A6VM)

Axial Piston Variable Motor AA6VM (A6VM) locked for new applications / Für Neuanwendung gesperrt Electric Drives and Controls Hydraulics Linear otion and ssembly Technologies Pneumatics Service xial Piston Variable otor 6V (6V) R 91604/09.07

More information

Axial Piston Variable Pump KVAA

Axial Piston Variable Pump KVAA Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics ervice Axial Piston Variable Pump KVAA A 92250/02.07 /16 eplaces: 02.04 echnical data sheet eries 6 izes 55...

More information

Axial Piston Variable Pump AA10VG

Axial Piston Variable Pump AA10VG Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics ervice xial Piston Variable Pump 10V 92750-/06.09 1/44 eplaces: 03.09 Data sheet eries 10 ize 18... 63 Nominal

More information

UŽSISAKYKITE internetu telefonu el. paštu

UŽSISAKYKITE internetu  telefonu el. paštu Features Axial piston pump MA10VO in swashplate design is used in open loop circuits. Flow is proportional to drive speed and displacement. By adjusting the position of the swashplate it is possible to

More information

Variable Displacement Pump A4VG for closed circuits

Variable Displacement Pump A4VG for closed circuits RE 92 003/05.99 RE 92 003/05.99 replaces: 02.98 Variable Displacement Pump A4VG for closed circuits Sizes 28...250 Series 3 Nominal pressure 400 bar Peak pressure 450 bar A4VG...EP Index Features 1 Ordering

More information

Variable Displacement Plug-In Motor A6VE

Variable Displacement Plug-In Motor A6VE Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics Service Variable Displacement Plug-In Motor A6VE RE 91 606/06.05 1/16 Replaces: 05.99 echnical data sheet Series

More information

Axial Piston Variable Pump A11VO

Axial Piston Variable Pump A11VO Electric rives and Controls Hydraulics Linear otion and ssembly Technologies Pneumatics ervice xial Piston Variable Pump 11VO E 92500/10.09 1/64 eplaces: 06.09 ata sheet eries 1 ize N40 to 260 Nominal

More information

Axial Piston Variable Pump A17VO

Axial Piston Variable Pump A17VO Electric Drives and Controls Hydraulics Linear Motion and ssembly echnologies Pneumatics ervice xial Piston Variable Pump 17VO E 92260/03.10 1/16 eplaces: E 92250 Data sheet eries 10 ize 55 to 107 Nominal

More information

Variable Axial Piston Pump (A)A10VSO

Variable Axial Piston Pump (A)A10VSO Industrial Hydraulics open circuit Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Variable Axial Piston Pump (A)A1VSO Size 18... 14 Series 31 Nominal pressure 4 psi (28

More information

Variable Plug-In Motor A6VE

Variable Plug-In Motor A6VE Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Variable Plug-In Motor A6VE RE 91 606/10.07 1/16 Replaces: 06.05 Technical data sheet Series 6 Size Nominal

More information

Axial Piston Variable Pump (A)A4VSG (US-Version)

Axial Piston Variable Pump (A)A4VSG (US-Version) Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Variable Pump ()4VSG (US-Version) R- 92100/12.12 1/72 Replaces: 10.97 Data sheet Series 10,

More information

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design Sizes 71 0 Nominal pressure 3 bar Peak pressure 400 bar RE 91455/01.94 RE 91455/01.94 Replaces 07.88 Other fixed displacement

More information

Fixed Plug-In Motor A2FE

Fixed Plug-In Motor A2FE Fixed Plug-In Motor 2FE RE 91 008/09.07 1/16 Replaces: 04.05 echnical data sheet Series 6 Sizes Nominal pressure/peak pressure 28 to 180 400/450 bar 250 and 355 350/400 bar Open and closed circuits Contents

More information

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RE 92 703/10.07 1/44 Replaces: 11.05 Technical data sheet eries 52/53 size

More information

Axial piston variable pump A4VSO Series 10, 11 and 30 for HFC hydraulic fluids

Axial piston variable pump A4VSO Series 10, 11 and 30 for HFC hydraulic fluids Axial piston variable pump A4VO eries 10, 11 and 30 for HFC hydraulic fluids RE 92053 Issue: 08.2015 Replaces: 03.2009 izes 71 to 355 Nominal pressure 350 bar Maximum pressure 400 bar Open circuit Features

More information

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model AA4VSE Plug-in dual displacement motor Series Axial piston swashplate design, SAE model RE 91808/09.90 RE 91808/09.90 Brueninghaus Hydromatik Size 250 Nominal pressure 350 bar Peak pressure 400 bar High

More information

Axial Piston Fixed Displacement Pump KFA

Axial Piston Fixed Displacement Pump KFA Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Axial Piston Fixed Displacement Pump KFA RE 91 501/06.03 1/12

More information

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A10VSO Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO RE 92714/09.07 1/28 Replaces 09.06 Technical Data heet ize 28... 180 eries

More information