- Damian O’Connor’
- 5 years ago
- Views:
Transcription
1 analytical bulk flow distance FLOW level pressure temperature industrial communication
2 Miniature Metal - Tube VA Meter General Features Suitable for liquids and gases Suitable for installation in which flow direction is from bottom to top Tapered metering section of rugged all-metal construction Standard Features - MMT18 With horizontal connections A needle valve at the inlet or bottom front of connection block isolv MMT18 and MMT19 are known as Miniature Metal Tube Variable Area flowmeters. These flowmeters are of all-metal construction which consist of metal measuring cone, stainless steel connection blocks and a die-cast zinc housing. Option Can be supplied without valve, or with outlet needle valve at the top connection block (OutLet) A maximum of two adjustable limit switches (L1, L2). The set limits are indicated on the scale. Addition of a differential pressure regulator Standard Features - MMT19 With vertical connections Without needle valve Option A maximum of two adjustable limit switches (L1, L2). The set limits are indicated on the scale. 2
3 Specifications Full-scale range (100% values): Water at 20 C (68 F): Air at bar abs., 20 C (14.7 psia, 68 F): 3 to 100 l/h (0.013 to 0.44 US GPM) 50 to 3400 l/h (0.031 to 2.11 SCFM) Turn-down ratio 10:1 Accuracy class (to VDI/VDE Code 3513, Sh. 2): 4 E a = AC ( ) F E a=error (% actual) F=% Full scale flow AC=Accuracy Class Scale graduation: Max. allowable operating pressure: at 20 C (68 F). 130 bar (1885 psig) flow units Test pressure is 1.3 times the specified operating pressure. Information on higher pressure levels supplied on request Max. process temperature: Without limit switch option 80 C to +150 C ( 112 F to +302 F) With limit switch option Ta<40 C (<104 F) Ta<50 C (<122 F) Ta<60 C (<140 F) (Ambient temperature Ta) 145 C 293 F 135 C 275 F 125 C 257 F Connections: Standard 1 /4 NPT female thread Adapters Ermeto 6 or 8, Serto 6 or 8, Others upon request Materials: Connection blocks, valve, plug Housing Cone, float Gaskets CrNi steel (316Ti) die-cast zinc CrNi steel (316 Ti) PTFE, other upon request Limit switch: Type SJ2-SN Number, max. 2 Electrical connection Right-angle plug, style to DIN 43650/ISO 4400, with PG 11 cable gland Max. signal cable length 1.5 m (5 ft) non-detachable Protection category to EN 60529/IEC 529 IP 65, equivalent to NEMA 12 and 13 An isolation switching amplifier is required to operate the SJ2-SN 3
4 Flow table Reference conditions Water at 20 C (68 F) Air at 20 C, bar abs. (68 F, 14.7 psia) 100% Flow values, Turn-down ratio 10 : 1 Cone No. Valve spindle diameter Water Air max. pressure loss mm l/h l/h mbar psig K K K K K K K K K Dimensions and weights in mm ( inches) MMT19 MMT18 Weight: 0.6kg (1.3 Ibs) Weight: 0.7kg (1.5 Ibs) 4
5 Differential pressure regulators Differential pressure regulators are used to help maintain constant flow rates at fluctuating operating pressure. Minimum pressure levels are required to permit operation of the regulators (see regulator characteristics) Differential pressure regulators are not pressure reducing valves Max. flow rate: 4000 I/h air or 160 I/h water. Pressure levels: CrNi steel (316 Ti) up to max. 25 bar [option 64 bar] Brass up to max. 16 bar (232 psig) Temperatures up to max. 80 C (176 F) [option 100 C] Application ranges Inlet pressure regulators, S-type The S-type regulator help maintain a constant flowrate for gases and liquids at variable inlet pressure and constant outlet pressure. Outlet pressure regulators, T-type For gaseous products, the T-type regulators help maintain a constant flowrate at variable outlet pressure and constant inlet pressure. For liquids, the S-type inlet pressure regulators can also be used to help maintain a constant flowrate at variable outlet pressure and constant inlet pressure. In order to function, the outlet pressure regulator requires a specific minimum pressure difference between inlet and outlet pressures. Inlet pressure P 1 must always be greater than outlet pressure P. 2 Type Identification Material Max. measuring range Min. inlet Min. differential Water** Air** pressure P 1 pressure* l/h l/h P 1 in bar p in bar Inlet pressure stainless steel regulators S-type stainless steel brass stainless steel brass stainless steel Outlet pressure brass regulators stainless steel T-type brass stainless steel brass * Differential pressure between inlet and outlet pressures ** Reference conditions: 20 C (68 F), bar abs. (14.7 psia). 5
6 Regulator Characteristics Inlet pressure regulators, S-type Outlet pressure regulators, T-type l/h 4000 l/h q v 2000 q v p - inlet pressure in bar (psig) 1 p - inlet pressure in bar (psig) 2 Example: inlet pressure 5 bar Air at 20ºC, bar abs., (68ºF, 14.7 psia) q = flowrate v Example: inlet pressure 3 bar Air at 20ºC, bar abs., (68ºF, 14.7 psia) q = flowrate v Dimensions in mm (inches) (use dimensions for installation) S-type T-type Weight approx.1.5 (3.31 Ibs.) Weight approx.1.5 (3.31 Ibs.) 6
7 Limit switch SJ2-SN for MMT18 and MMT19 The SJ2-SN limit switch is a slot sensor with built-in preamplifier. The sensor is activated by the dipping action of an aluminium vane that is mounted on the pointer shaft of the flowmeter. The limit switches can be set over the full measuring range. The set limits are indicated on the scale. An isolation switching amplifier is required for operation of one limit switch. Technical data SJ2-SN Rated voltage 8 VDC Power consumption active area clear >3 ma active area obscured <1 ma Protection category EN 60529/lEC 529 IP 67 (NEMA 6) Ambient temperature 25 C to +65 C Electromagnetic compatibility (EMC) to EN , EN Electrical characteristics to DIN EN (NAMUR) Only relevant for use in hazardous areas Only for connection to intrinsically safe circuits with the following peak values: No-load voltage U O 8 VDC Short-circuit voltage I k 8 ma Self-inductance (Li) 3 μh Self-capacitance (Ci) 230nF Individual approval PTB-No. Ex-95.D.2195X 7
8 SALES AND SERVICE CENTRES REGIONAL NETWORK CHINA FLOTECH CONTROLS (SHANGHAI) CO., LTD B-C, Songhu Industrial Zone, No.3 Yanghebang Road, Songjiang High-tech Park, Shanghai, P.R.C (201615) Tel: (86) Fax: (86) 福德控制仪器 ( 上海 ) 有限公司地址 : 上海松江高科技园区洋河浜路 3 号松沪工业小区 B 区 C 栋邮政编码 : 电话 : (86) 传真 : (86) 电子邮件 : info@flotechshanghai.com INDONESIA PT FLOTECH CONTROLS INDONESIA Komplek Rukan Artha Gading Niaga Blok F/7, Jln. Boulevard Artha Gading Jakarta 14240, Indonesia Tel: (62) Fax: (62) salesjkt@flotech.co.id SINGAPORE - HEAD OFFICE FLOTECH CONTROLS PTE LTD 438 Tagore Industrial Avenue Singapore Tel: (65) Fax: (65) info@flotech.com.sg Website: Reg. No H Branch Office Pekanbaru Tel : (62) Fax : (62) Certificate SG95/04276 Certificate SG13/04547 MALAYSIA M - FLOTECH CONTROLS SDN BHD No. 20, Jalan TP 7/6 Taman Perindustrian UEP Subang Jaya Shah Alam Selangor Darul Ehsan Malaysia Tel: (60) /6 Fax: (60) sales@mflotech.com.my 24_0314
VLS SERIES Vibration Type Level Sensor
Vibration Type Level Sensor The VLS series is a piezoelectric driven vibration type level switch that detects the level in bins, silos and hoppers, filled with grained or powdered materials (bulk solids).
More informationGA 24 Heavy-duty variable area flowmeter
KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationVariable area flowmeter H 250
KROHNE 10/99 D 11 H250 01 E GR Variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments
More informationModel Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G
Data Sheet Field IT Variable Area Flowmeters Armored Purgemeter 10A3200 n n n Function - The armored variable area flowmeter offers new possibilities for metering small flowrates of liquids and gases.
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationVariable Area Flowmeters Armored Purgemeter
Data Sheet (US) Variable Area Flowmeters Armored Purgemeter 10A3200 Function - The armored variable area flowmeter offers new possibilities for metering small flowrates of liquids and gases. The instrument
More informationMetal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam
Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in
More informationAr-Mite TM Low Flow Armored Flowmeter
Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationSYNCHRON. Seating Products
SYNCHRON Seating Products Synchron Series Synchron series is an enlightened choice for executives, professionals and managers. Fine leather upholstery and majestic designs make it extraordinary and suitable
More informationI Ex-control stations I
Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More informationN485J-3 船用柴油机组零件图册. (East China Shipbuilding Institute Factory) 镇江四洋柴油机制造有限公司 ( 原华东船院工厂 )
四洋 R N485J-3 Marine Diesel Engine Set Parts Catalogue N485J-3 船用柴油机组零件图册 ZHENJIANG SIYANG DIESEL ENGINE MANUFACTURING CO.,LTD CHINA (East China Shipbuilding Institute Factory) 镇江四洋柴油机制造有限公司 ( 原华东船院工厂 )
More informationWAU. Seating Products
WAU Seating Products Sports Design Concept 02 Wau combines excellent ergonomics to extract human performance and trendy styling to elicit self confidence and satisfaction as you perform. 04 05 Wau Recline-Glide
More informationFlap-Type Flow Meter Prall
Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional
More informationBrooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008
Data Sheet GT1000 Series Brooks GT1000 Series Industrial Glass Tube Variable Area Flowmeters Model GT1020 Model GT1024 DESIGN FEATURES Brass or 316L SS (1.4404) end fittings Flanged or threaded connections
More informationRapier AX Air Break Switch Disconnector. providing intelligent solutions
Air Break Switch Disconnector providing intelligent solutions Air Break Switch Disconnector providing intelligent solutions Lucy Switchgear would like to present its Air Break Switch Disconnector. The
More informationFlow switches Series AD/VH
Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,
More informationOperating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content
1. bout this document EN Operating instructions............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationRapier AX Air break switch disconnector
Rapier AX Air break switch disconnector engineering intelligent solutions Air break switch disconnector Lucy Electric would like to present its Air break switch disconnector. The Rapier AX is compact and
More informationGeneral Specifications
General Specifications Model RAGG Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in
More informationAcuLok TMO. Transformer Mounted Distribution Cabinets
AcuLok TMO Transformer Mounted Distribution Cabinets AcuLok TMO Transformer Mounted Low Voltage Distribution Cabinets featuring AcuLok Fuse Handle technology AcuLok TMO is a ground breaking development
More informationDifferential pressure gauge with diaphragm
Differential pressure gauge with diaphragm and switch function,type series BG2 Features Differential pressure gauge with diaphragm and switch function Nominal range -40...0 mbar to -1...24 bar, 0 40 mbar
More informationDifferential Pressure and Flow meters Accessories for the Media Series
Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the
More informationGiving reliability and cost effectiveness a lift. EKKE-Bas single-girder and ZKKE-Bas double-girder overhead travelling cranes EKKE ZKKE.
Giving reliability and cost effectiveness a lift EKKE-Bas single-girder and ZKKE-Bas double-girder overhead travelling cranes EKKE ZKKE Innovation 2012 Demag Bas products robust, durable engineering Demag
More informationYOKOGAWA. General Specifications. Model RAKC Short-tube Rotameter. GS 1R1B3-E-H 4rd Edition
General Specifications Model RAKC Short-tube Rotameter A conical float is guided into a cylindrical metal tube provided with an orifice plate. The position of this float is magnetically transmitted to
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationDMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial
More informationGeneral Specifications
General Specifications Model RAGG Rotameter GS 01R01B06-00E-E This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float
More informationGeneral Specifications
General Specifications Model RAKD Small Metal Rotameter A float is guided concentrically in a conic metal tube. The position of this float is magnetically transmitted to the indicator. The shorttube Rotameter
More informationOPTIGAS 4010C Technical Datasheet
OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation
More informationJoinluck Electronic LED Lighting Products
苍乐 Joinluck Electronic E ighting Products THE JOINUCK E ighting Products INTROUCTION Established in 1988, JOINUCK has become a leading manufacturer of energy efficient lighting products. JOINUCK has two
More informationGeneral Specifications
General Specifications Model RAKD Small Metal Rotameter GS 01R01B30-00E-E A float is guided concentrically in a conic metal tube. The position of this float is magnetically transmitted to the indicator.
More informationOPTIGAS 4010C Technical Datasheet
OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation
More informationAlarm contacts for pressure gauges and thermometers
Alarm s for pressure gauges and thermometers Electrical alarm s with magnetic snap-action s or sliding s Operating principle: Magnetic snap-action or sliding s in pressure gauges resp. thermometers are
More informationLimit Switch Type 4747
Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical
More informationAbsolute pressure gauge with diaphragm
Absolute pressure gauge with diaphragm and switch function,type series BF2 Features Absolute pressure gauge with diaphragm and switch function Nominal ranges 0 60 mbar abs to 0 2500 mbar abs With integrated
More informationInductive Proximity Sensor
Inductive Proximity Sensor Square Proximity Sensor Limit switch styled housing models easy to install. Standard CENELEC models and miniature types. Terminal housing, M12 Plug--in connection and cable types.
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat. N/en
00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable
More informationSTADIUM. Seating Products
STADIUM Seating Products 02 Seating Excellence at Work Merryfair s outdoor stadium seating collection. Durable seating available in vibrant colours. Discover the Sporta, Ola, Oahu. 03 04 Comfort The tip-up
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve
More informationTHE JOINLUCK Compact Fluorescent Family
THE JOINUCK Compact Fluorescent Family JOINUCK JOINUCK CF - Spiral Series Tube iameter: 7.8mm. Ultra compact design enables them to fit almost anywhere incandescent bulbs fit. Minimal light trapping
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More informationPRODUCT IDENTIFICATION & COMPANY
TECHNICAL DATA SHEET PRODUCT NAME : FLOW METERS SECTION 1 PRODUCT IDENTIFICATION & COMPANY Product Name Flow Meters ( FLOWTECH & BLUE & WHITE) Supplier EZ Water Technology Address 1647 S, Main St. Suite
More informationAgilent 490 Micro GC Internal and External Mount Genie Filter Brackets
Agilent 490 Micro GC Internal and External Mount Genie Filter Brackets Installation The Genie Filter Bracket kits include mounting hardware to install a sample line filter on an Agilent 490 Micro GC. Agilent
More informationOrifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam
Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationDMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600
More informationFlowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.
Flowmeters with Float Series 6001/ 6002 Flow Measurement of Gases & Clear Liquids with Float Series 6001 & 6002. Measurement Principle Variable area obtained by the displacement of a float in a conical,
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationVariable Area Flowmeters Ori-Flowrator TM Meters
Data Sheet (US) Variable Area Flowmeters Ori-Flowrator TM Meters 10B4000 Low installation cost Linear indication over 12-1/2 to 1 flow range Inexpensive method of measuring large flow rates in direct flow
More informationStainless Steel Centrifugal Pump Type 3 SERIES
PUMP Stainless Steel Centrifugal Pump Type APPLICATIONS Water supply to civil, agricultural and industrial plants Pressure boosting Fire-fighting, heating systems and air-conditioning Moving industrial
More informationDMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up
More informationVA 40. Variable-area flowmeter. For explosion protected devices please refer to Supplementary Installation an Operating Instructions:
KROHNE 01/2005 7.02266.22.00 GR Installation and Operating Instructions VA 40 Variable-area flowmeter For explosion protected devices please refer to Supplementary Installation an Operating Instructions:
More informationXMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.
Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others
More informationPressure transmitter JUMO dtrans p02
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP
More informationDMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.
DMK P Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals
More informationGeneral Specifications
General Specifications Model RAGK Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in
More informationGlass Tube Flowmeter Model GT1000
Model GT1020 Model GT1024 Description DS-VA-GT1000-eng March, 2016 Data Sheet Glass Tube Flowmeter Model GT1000 Variable Area Industrial Glass Tube, Variable Area Flowmeters The Brooks GT 1000 combines
More informationGeneral Specifications
General Specifications Model RAKD Small Metal Rotameter GS 01R01B30-00E-E A float is guided concentrically in a conic metal tube. The position of this float is magnetically transmitted to the indicator.
More informationVariable-Area Flowmeter BGN. Device Description
Variable-Area Flowmeter BGN Device Description Contents 1 IDENTIFICATION... 4 1.1 Supplier/manufacturer... 4 1.2 Product type... 4 1.3 Product name... 4 1.4 Issue date... 4 1.5 Version no... 4 2 APPLICATIONS...
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationJUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb
sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure
More informationPlastic tube variable area flowmeter for liquids and gases
Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)
More informationMagnetic switch For bypass level indicators Model BGU for nuclear power plants
Level measurement Magnetic switch For bypass level indicators BGU for nuclear power plants KSR data sheet BGU for NPP Applications Magnetic switches for detecting the limits of filling levels in bypass
More informationNAMUR FLANGE: With integrated exhaust air recirculation Ordering information
00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationAM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationDMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm
Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals
More informationVariable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500
Data Sheet (US) Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500 Rugged body design with all type 300 stainless steel construction Metering tube can be removed for range change
More informationKDG/KDF - Flow Meter and Flow Switch
Integral Flow Control Valve Easy to Read Scale Brass, SS, or PVDF Process Connections Direct Reading Scales for Water and Air Compact Economical Design Optional Panel Mounting Kit Optional Flow Switch
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationIsabellenhütte Resistors Selection Guide
Precision and power resistors for current measurement Internationally, Isabellenhütte belongs to the leading manufacturers of low -impedance precision resistors. Regardless whether of simple design or
More informationPneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767
Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Application Single-acting or double-acting positioners for attachment to pneumatic control valves. Supplied with a pneumatic input signal
More informationENERGY SERVICES PTE LTD.
V-100 product information Variable area flowmeters for gases and liquids ESTERN ENERGY SERVICES PTE LT. 60 aki Bukit Place #02-19 Eunos Tech Park Singapore, SG 415979 Singapore Telephone: +65-6748 6911
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationGeneral Specifications
General Specifications Model RAKD Small Metal Rotameter GS 01R01B30-00E-E A float is guided concentrically in a conic metal tube. The position of this float is magnetically transmitted to the indicator.
More informationYOKOGAWA. General Specifications. Model RAMC-Series Metal Short-stroke Rotameter
General Specifications Model RAMC-Series Metal Short-stroke Rotameter Rotameters operate on the principle of generating a condition of dynamic balance within the flow meter in which a float is positioned
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationDifferential Pressure Sensors
1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and
More informationMEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP
MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP DESCRIPTION The MEMFlo MFTV Metal Bodied Flow Meters with Clear Top are simple, accurate, meters for use in a wide range of industrial liquid and gas
More informationk Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.
Pressure Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS23.100 and PGS23.160 k Applications for further approvals see page 7 WIKA data sheet PV 22.02
More information3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"
/2 Way Pilot Valve /2 Way Solenoid Valve 1 /" and 1 /2" 5/2 Way Solenoid Valve 1 /" 6/2 Way Solenoid Valve 1 /" 5/ Way Solenoid Valve 1 /" General The solenoid valves consist of one or two /2 way pilot
More informationThe New Filter Valve Technology
The New Filter Valve Technology HIGH FLOW, QUICK RESPONSE.. Connections Ports available in NPT, and BSPP G thread to international standards Response Minimized space above the diaphragm guarantees fast
More informationLimit Switches. Series NI700 Installation, Maintenance and Operating Instructions
Limit Switches Series NI700 Installation, Maintenance and Operating Instructions 7 NI 72 en 12/2008 2 7 NI 72 en Table of Contents 1 INTRODUCTION... 3 1.1 General description... 3 1.2 Markings... 3 1.3
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationSeating Excellence at Work
Products News Contact Seating Excellence at Work Merryfair was established in 1974 to manufacture component parts and sooner ventured into making office chairs in 1982. We soon became a leading office
More informationActuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage
Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact
More informationGeneral Specifications
eneral Specifications Model RAH Rotameter S 01R01B05-00E-E This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting
More informationDifferential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160
Pressure Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT43.100 and DPGT43.160 k Applications Acquisition and display of process values Output
More informationJUMO dtrans p20 DELTA
Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision
More informationComponents and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel
- 1 - Documentation about Ex i - 45 C 8 V DC limit switch boxes with Pepperl+Fuchs sensors for pneumatic rotary- and linear actuators acc. to guidline 2014/34/EU, IBExU 04 ATEX 1211 II 2G Ex ia/ib IIC/IIB
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20
More informationMETAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER
TECHNICAL INFORMATION METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER Electronic Transmitter INTRODUCING THE METAL TUBE VAREA-METER U.S. Filter/Wallace & Tiernan Products straight through metal tube
More informationDMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet