HARMONIC FILTER REACTOR
|
|
- Alexander Craig
- 6 years ago
- Views:
Transcription
1 380V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.13 x l N 10 MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH
2 380V 50Hz Series Resonance Frequency : 189Hz or p = 7% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.11 x l N 10 MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH
3 Filtering with Holly harmonic circuit filter reactor provides the 400V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 440V capacitor only Design : According VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.11 x l N 10 MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH
4 Filtering with Holly harmonic circuit filter reactor provides the 400V 50Hz Series Resonance Frequency : 189Hz or p = 7% To be used with 440V capacitor only Design : According VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.11 x l N 10 MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH
5 415V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 525V capacitor only Rated Voltage : 600V Load Carrying Capacity : Insulation Class : 155 C or Class F l N = Current from Q LC without harmonic load Thermo-protection : Fitted with 135 C thermostat l 250 = 0.31 x l N Design : According to VDE 0550/0532 & IEC 76 l 350 = 0.11 x l N Ambient Temperature : 60 C, maximum ambient temperature l TH = 1.22 x l N = Max. permissible effective value of Linearity Characteristics : 1.50 x 1 N at no change of inductivity the current considering 10% over 1.75 x 1 N at reduction of the inductivity voltage and the permissible harmonic currents 10 MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH
6 415V 50Hz Series Resonance Frequency : 189Hz or p = 7% To be used with 525V capacitor only Rated Voltage : 600V Load Carrying Capacity : Insulation Class : 155 C or Class F l N = Current from Q LC without harmonic load Thermo-protection : Fitted with 135 C thermostat l 250 = 0.31 x l N Design : According to VDE 0550/0532 & IEC 76 l 350 = 0.11 x l N Ambient Temperature : 60 C, maximum ambient temperature l TH = 1.22 x l N = Max. permissible effective value of Linearity Characteristics : 1.50 x 1 N at no change of inductivity the current considering 10% over 1.75 x 1 N at reduction of the inductivity voltage and the permissible harmonic currents 10 MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH MH-GH
Power Factor Correction Capacitors in sheet steel cases
Power Factor Correction Capacitors in sheet steel cases Power Capacitors type LKN and LKSLT for fixed compensation of, for example, motors and transformers LKN LKSLT Sheet steel case With terminal block
More informationMODVAR Low voltage reactive power compensation modules Installation manual
MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Before installation, read this manual carefully and keep at the disposal
More informationChapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design
Dynamic power factor correction systems (real time PFC) Optimised, thermal design Long service life De-tuned version Minimised grid distortion Dynamic power factor correction systems (real time PFC) Hardly
More informationLV Capacitor CLMD03 Power Module Instruction manual
LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...
More informationHigh Reliable Components for Power Factor Correction and Power Quality
High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Contents Power Factor Correction Capacitors Page 3 Basic Harmonic Filter Reactors Page 11 Standard
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationCTU 02. Thyristor switching module for fast PF compensation. User manual
CTU 02 Thyristor switching module for fast PF compensation User manual version 1.3 Czech Republic Czech Republic 1 Content 1. Function description... 3 2. Device description and indication features...
More informationHigh Reliable Components for Power Factor Correction and Power Quality
High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Power Factor Correction Capacitors Type LKT Features that matter: Overcurrent up to 2.2 times rated
More informationLCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.
LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2
More informationLINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)
LINEAR LED DRIVERS ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186443, 186444, 186486, 186487, 186488, 186491, 186492, 186737 Typical Applications Built-in in linear luminaires for Office lighting
More informationAIR CORE REACTORS. Phoenix Electric Corporation
AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed
More informationTransforming Energy.. For Advanced Technology
Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial
More informationMedium Voltage Capacitors
Type MSCE and MSCD Features that matter: Single and Three-Phase Capacitors Up to 22 kv (50 / 60 Hz) Up to 1000 kvar For indoor and outdoor installation 1 Type MSCE and MSCD Application Product Scope The
More informationThree Phase Capacitors KNK
Three Phase Capacitors KNK Features Connection profile Φ 90 and 116 mm 2-16 mm 2, Φ 136 mm 2-25 mm 2 *Use of flexible conductors only with ferrules Capacitors equipped with discharge resistors Rated power
More informationTechnical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction
Technical brochure The Vector series The ABB comprehensive solution for automatic power factor correction 2 Applications The Vector series The Vector series The Vector series is a powerful and compact
More informationProduct Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A
Proficient. Innovative. Customer-orientated Transformers up to 8MVA AC/DC Reactors up to 3000A Power Transformers Cast Resin Transformers High-Current Transformers AC/DC Reactors Variable Transformers
More informationmulticond Power capacitors Data sheet: multicond
Power capacitors multicond Monitoring Optimizing Recording multicond are one-phase and three-phase power capacitors for reactive current compensation, developed for networks with many harmonics. Apart
More informationLV Capacitor CLMD Reliability for Power Factor Correction
LV Capacitor CLMD Reliability for Power Factor Correction Reliability for power factor correction CLMD construction The CLMD capacitor consists of a number of wound elements made with a dielectric of metallized
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationVW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive
Characteristics line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive Main Range of product Product or component type Product compatibility Mar 30, 2019 Altivar Line/motor choke ATV31CU22N4
More informationLow voltage capacitors CLMD Improving power factor and enhancing power quality of your network
PRODUCT BROCHURE Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network s.a. ABB n.v. Power Quality Products Allée Centrale 10 Z.I. Jumet B-6040 Charleroi (Jumet)
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationCONVERTER-FED MOTOR LOSSES
CONVERTER-FED MOTOR LOSSES - AN IMPROVED MEASUREMENT METHOD Andrew H. Baghurst CalTest - Port Elliot, South Australia Motor Summit, Zurich, Switzerland 11/12 October 2016 INTRODUCTION The undoubted advantages
More informationVW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive
Characteristics line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive The information provided in this documentation contains general descriptions and/or technical characteristics
More informationAutomatic COSYS PFC. Automatic power factor correction system NEW
Automatic COSYS PFC Automatic power factor correction system NEW cosys_178_a_1_x_cat cosys_178_a_1_x_cat appli_xxx_a  Function Your reactive energy consumption vary depending on the type and using conditions
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationVW3A4552. Product datasheet Characteristics. Main 1 / 5
Product datasheet Characteristics VW3A4552 Main Range of product Product or component type Product compatibility Altivar Line/motor choke ATV31CU22N4 - line choke - 1 per ATV31CU22N4 - motor choke - 1
More informationEasy Choice for Energy Efficiency
Easy Choice for Energy Efficiency EasyCan The new generation LV power factor correction capacitors EasyCan The new generation LV power factor correction capacitors What is power factor correction? In electrical
More information2 SLR Series Line Reactors... 50
Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...
More informationABB n.v Power Quality in LV installations
ABB n.v. - 1 - Power Quality in LV installations PQ problems in LV installations 750 500 250 Volts 0-250 -500 Amps -750 3000 2000 1000 0-1000 -2000-3000 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75
More informationPower factor correction and harmonic filtering. Power capacitors Low Voltage
Power factor correction and harmonic filtering Power capacitors Low Voltage R.2 - Low voltage power capacitors CLZ-FPT Tubular capacitor, Faston terminal R2-7 CLZ-FP Tubular capacitor with terminal connection
More informationLED control gear Compact fixed output
Driver LCI 65 W 1400/1750 ma TEC SR TEC series Product description Independent fixed output LED Driver Constant current LED Driver Output current 1,400 or 1,750 ma Max. output power 65 W Nominal life-time
More informationROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,
ROBUST LED DRIVERS EasyLine INDUSTRY 186452, 186453, 186454, 186455, 186456, 186477, 186510, 186617 Typical Applications Built-in in compact luminaires for Industrial lighting EasyLine Industry ENCAPSULATED
More informationBraking Devices BR 230/ Assembly- and Commissioning Instructions
electronic Braking Devices BR 230/400-10...400 Assembly- and Commissioning Instructions Quality is our Drive. BR 230/400-10...400 1 as per 04/10 11600.10001 Table of Contents Page 1. Safety notes 3 2.
More informationMains Filters. IEC Connectors. IEC Connectors 292
IEC Connectors Mains Filters Designed to reduce conducted mains borne EMI, this extensive range provides many solutions to EMI problems. To meet individual design requirements the filters are available
More informationThis instruction manual must be read carefully and should be always given to the end user of the device.
Product Manual Input reactor Motor reactor for TOSHIBA Inverter This instruction manual must be read carefully and should be always given to the end user of the device. Possible subject to modifications
More informationAC/DC Arc Furnace and Ladle Furnace Transformers
AC/DC Arc Furnace and Ladle Furnace Transformers Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard
More informationPower Factor Correction Capacitors Harmonic Filter Reactors
CONSISTENT QUALITY SUPERIOR TECHNOLOGY ENERGY EFFICIENT Harmonic Filter Reactors Tibrewala Electronics Limited About Us As one of the most renowned manufacturers of Capacitors and MPP Film in India, Tibrewala
More information100V 160V 200V 250V 400V
CL12 Polyester Film Capacitors Structures: Polypropylene film, non- inductive, phenolic resin coating Features: Excellent frequency and temperature characteristics, Very small loss even at high frequency.
More informationTachogenerators Solid shaft ø11 to ø14 mm with flange
Features Low response time Open circuit voltage 40...175 mv per rpm Redundant output () Solid shaft ø1114 mm High signal quality due to patented LongLife technology Optional Second shaft end (B14) Technical
More information1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN
APPLICATION The KNK capacitors are used for power - factor correction of inductive consumers (transformers, electric motors, rectifiers) in industrial networks for voltages of up to 660 V. DESIGN Cylindrical
More informationPOWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager
POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar Abel-Zhang,Power Quality Center Manager Contents Capacitor Unit Capacitor Shunt Bank Type Solution of Filter March 7, 2017 Slide 2 Contents
More informationDouble insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators
Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)
More informationUnrestricted. Air Core Reactor Applications Current Limiting Reactors
Unrestricted Air Core Reactor Applications Current Limiting Reactors Faults on Electrical System - Basic Concepts Three major concerns arise from this scenario: 1- The mechanical stresses on the transformer
More informationR.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :
R.4 Power factor correction and harmonic filtering Automatic capacitor banks with static system Mail: Hberk@circutor-nrw.de Homepage : www.berk-iv.de Kontakt: Berk Industrievertretung 51103 Köln Erna Schaeffler
More informationAutomatic capacitor banks
NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Automatic
More informationCheck points for the connection of Capacitor&Reactor
Application Reactor is used in conjuction with capacitor banks in series. Its main function is to compensative or produce reactive power. According to the purpose of use, reactor helps to limit inrush
More informationFUJI Magnetic Contactors and Motor Starters
FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...
More informationRasuunDrive. HighVac 10mm - Type 3. Technical Supply Specifications: RasuunDrive HighVac 10mm - Type 3. Attributes. Highlights.
RasuunDrive HighVac 10mm - Type 3 Attributes Highlights Description Wide travel range Vacuum suitable lubrication Zero backlash at optimised fit between speed and resolution Integrated limit switches Easy
More informationGlobal data. Electrical parameters
()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into
More informationINSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.
INSTITUTE OF TESTING AND CERTIFICATION (INDIA) VT. LTD. 25 6 Classification A control is classified 6. According to nature of supply 6.. Control for a.c. only 6..2 Control for d.c. only 6..3 Control for
More informationPSB / RSB - (Expanded range)
Main applications Snubber capacitor for energy conversion and control in power semiconductor circuits, resonant circuits, protection circuits in SMPSs, induction heaters, high voltage, high current and
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationYN018GMFI16M2D-V V~ 60Hz 1Phase Serials: PRE
Sale model: ProdCode: YN018GMFI16M2D-V1 220057000460 208-230V~ 60Hz 1Phase PRE 50130047 No. Part Name Quantity BOM code Bin Code Remark 1 Rear net 1 2011481G0001 8 2 Ambient temperature sensor assembly
More informationDimensional Drawing 48ZJ94. Lake Forest, IL USA. Dayton Electric Mfg. Co. REV. - DRAWING NO. PAGE OF REV. 48ZJ94
imensional rawing V G G V ayton lectric fg o Lake orest, L 64 4 Grainger, nc his design may not be reproduced, modified or redistributed without written permission from Grainger, nc otor erformance V L
More informationPower Factor Correction
Power Factor Correction It's all about saving your money! Features that matter n Overcurrent up to 2.2 times rated current n Inrush current up to 300 times rated current n Self-healing type, segmented
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More information2-position electric actuators with Ball valves VBZ ½...11/4
4 831.2 & VBZ ½...11/4 2-position electric actuators with Ball valves VBZ ½ 11/4 90 angle - Unidirectional rotation VBZ ½ 11/4 Electric rotary actuators for two-port ball valves Operating voltage AC 230
More informationG7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press
Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/
More informationIEC Connectors Mains Filters
IEC Connectors Mains Filters Designed to reduce conducted mains borne EMI, this extensive range provides many solutions to EMI problems. To meet individual design requirements the ilters are available
More informationCOMPONENT Type SS21-UL Type
SPEED CONTROL MOTORS COMPONENT Type Type A tachogenerator built into induction motors, in combination with the specially designed control pack, allows multi-functional operation such as speed control,
More informationPower Factor Correction Capacitors Type LKT
Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Self-healing type,
More informationSINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options
/2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions
More informationSINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions
More informationPower factor solutions for electric switchboards
Power factor solutions for electric switchboards DO IT YOURSELF Tecnología par la eficiencia energética Your global partner Viladecavalls (Barcelona - Spain) Alcobendas (Madrid - Spain) Viladecavalls (Barcelona
More informationDX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationPower Factor Correction Equipment
Power Factor Correction Equipment Content KNK Power Capacitors for Low Voltage GENERAL 4 KNK5015 - Cylindrical Aluminium Housing 6 KNK5065 - Cylindrical Aluminium Housing (delta connection) 8 KNK1053
More informationINTERROLL DRUM MOTOR 113S
DRUM MOTOR Product Description Material Versions Applications Characteristics The drum motor is a perfect drive station for small and medium-duty conveyor systems. Light-duty conveyors Packaging equipment
More informationSharda Electronics & Co. An ISO 9001:2015 Certified Company
Sharda Electronics & Co. An ISO 9001:2015 Certified Company Business Profile We have been witnessing to change all our life and change continues to happen all around us every moment. Change is happening
More informationNEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:
LKT Heavy Duty s NEW Overcurrent up to 2.7 times rated current Inrush current up to 450 times rated current Mean Life expectancy: 200,000 h. Up to 100,000 annual switching operations Features that matter:
More informationFilm Capacitors Power Factor Correction
Series/Type: PhiCap series with fast-on terminals Ordering code: Date: November 2009 Version: 1 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please
More informationSeries A DC Link Chokes
Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS
More informationLow Voltage Power Factor Corrections
Low Voltage Power Factor Corrections Capacitors Contents General information on Iskra Capacitors Type Page Introduction 4 1. Single-phase capacitor type KNK5015 230 550 V, 1,67.5 kvar 2. Three-phase capacitors
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationAC centrifugal fan with housing (small flange)
DE-HT- ebm-papst Mulfingen GmbH & Co. KG Bachmühle Mulfingen Phone: + - Fax: + - www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor DE-HT- ME-EC Phase ~ ~ Nominal voltage [V] Frequency [Hz]
More informationApplication Note. Dynamic PFC: Power Quality at the Docks (China State Shipbuilding Corporation)
Dynamic PFC: Power Quality at the Docks (China State Shipbuilding Corporation) P o w e r Q u a l i t y S o l u t i o n s www.epcos.com/pfc s The collection of PQS s is a library with in-depth information
More informationAC Line / Load Reactors
AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100
More informationMODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)
MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference
More informationPhiCap Capacitors for Power Factor Correction
PhiCap Capacitors for Power Factor Correction Product Profile 2000 http://www.epcos.com PhiCap AC Capacitors for Power Factor Correction General The PhiCap series, is a well approved and reliable EPCOS
More informationMedium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB
Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...
More informationACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]
ACME SCREW LINEAR ACTUATOR ATL 02 Stroke Actuator with DC motor La =Lc + Stroke Lc T OVERALL DIMENSIONS Rear bracket SP Pin Actuator with or 3-phase motor Capacitor Stroke end reed switches FCM Motor cable
More informationAC Motor Systems US Series
US Series The US Series combines a control unit and an AC speed control motor. Connection between the motor and control unit is simplified by an easy-to-use connector. The US Series is designed for applications
More informationNH DIN Dual Indication Fuse Links
Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide
More informationThermal Overload Relays - WEG RW Series, 2 Pole
International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be
More informationThe information in this chapter will enable you to: 90VAC to 50/60 Hz
C H A P T E R ➃ Hardware Reference The information in this chapter will enable you to: Use this chapter as a quick-reference tool for most system specifications (dimensions and performance) Use this chapter
More informationPower conversion systems for energy storage. Engineering that stores
Power conversion systems for energy storage Engineering that stores INDRIVETEC Innovative Drive Technologies AG The Company Indrivetec specialises in development and manufacture of high-performance storage
More informationMADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers
Product English Power Quality Components for reactive power compensation MADE IN GERMANY Components for reactive power compensation. Reactive power controllers Filter circuit reactors Capacitor contactors
More informationPower capacitors Low Voltage
NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Power
More informationSelective main circuit breakers S 750 series Technical Data
Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.
More informationItem: Type: SAW Resonator TO39, F11, F12. Optional
SPECIFICATION Item: Type: TO39, F11, F12 Optional Scope This specification shall cover the characteristics of 1-port SAW resonator. TO39 F11 F12 The 1-port is designed to be the frequency control element
More informationCLMD Low-voltage capacitors for reliable power factor correction
CLMD Low-voltage capacitors for reliable power factor correction Reliability for power factor correction CLMD construction The CLMD capacitor consists of a number of wound elements made with a dielectric
More informationMotor Valve GS 1 series, DN 15 up to DN 150
Motor Valve 8036 GS 1 series, DN 15 up to DN 150 Motor valve for control and switching of neutral through to highly aggressive media in process engineering, chemical industries and for plant equipment.
More informationACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke
ACME SCREW LINEAR ACTUATOR CLA 20 OVERALL DIMENSIONS Stroke La =Lc + Stroke Lc T La =Lc + Stroke Lc T Rear bracket SP Pin FC switches and potentiometer Attachment A1 Attachment A2 Motor cable length 0.3
More informationBraking Devices VB 230/ Assembly- and Commissioning Instructions
electronic Braking Devices VB 230/400-40... 600 Assembly- and Commissioning Instructions Quality is our Drive. VB 230/400-40... 600 1 as per 05/15 19700.10001 Table of Contents Page 1. Safety notes 3 2.
More informationGENERAL CATALOG. Group of Companies
GENERAL CATALOG 2019 Group of Companies Our Trademarks by Aktif Where we are? Switchgears & Substations Air Insulated Metal Enclosed Switchgears...8 Air Insulated Metal Clad Switchgears...10 Switching
More informationMedium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks
Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks Product Selection & Application Guide Product Description GE's Thyristor Switched Harmonic Filter Banks (TSC), are custom designed
More informationAssembly- and Commissioning Instructions Braking Devices VB 230/
electronic Assembly- and Commissioning Instructions Braking Devices VB 230/400-40... 600 Qualität ist unser Antrieb. VB 230/400-40... 600 1 as per 04/10 19700.10001 Table of Contents Page 1. Safety notes
More informationEPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015
e EPRLAB FAQ v1.0 Page 1 / 8 e EPRLAB Electric Power Research Laboratory, EPRLAB is a high-tech power electronics company that has been specialized on design, manufacturing and implementation of industrial
More information