Table of Contents Product Catalogue 4.0. Product Type Page Product Type Page
|
|
- Christal Hall
- 6 years ago
- Views:
Transcription
1 Table of Contents Product Catalogue 4.0. Product Type Page Product Type Page Ducts SPR Bends BPL BP BPN BPNR BPKL/BPKFL BPK, BPKF BSL BS BSKL BSK BSDL, BSD BPL, BP BSL, BS BSKL BSK BPL BP BPN BPNR BPKL, BPKFL BPK, BPKF BSL BS BSKL BSK BPL, BP BSL, BS BSKL BSK BPL, BP BSL, BS BSKL BSK Lateral SSCVL, SSCV collar saddles T-pieces TPCL, XPCL TPC, XPC TPCL-CP-R, TPC-CP-R TPC-CP-R-I, TPCL-CP-R-I TSCL, TSL, XSCL, XSL, TSC, TS, XSC, XS. 103 TPCL, XPCL, TPC, XPC COLL TSVL, TSV-45, XSVL, XSV Y-pieces YSVL YSV Couplings NSL NS SNSL MSF SMSFL Take-offs ILPRL ILPR ILSL ILS ILSF Take-offs ILSV-45, ILSVL Reducers RPCL RPC RPCN RPCNR RPCFL RPCF RPCL, RPCFL, RPC, RPCF RSCLL, RSLL, RSCLFL, RSLFL RSFC, RSFCF, RSFCL, RSFCFL Angle ASV take-offs with mesh Take-offs ILSN with mesh Collar SPL saddles SP SPSL SPS SSCL, SSL, SSC, SS SSCCB SSCCBL SSCFB SSCFBL Balancing ILA dampers ILA-K End caps CSL CS CP CPF CSN
2 Table of Contents Product Catalogue Product Type Page Product Type Page Offsets ODSOL, ODSO Collar with GALA EPDM Gasket Gaskets GASK Take-offs KILL with plate KIL Suspension CLRL-C rings CLRU CLR, CLRL Perforated PB suspension bands Duct FAA, FAAL, FAAT supports Foots ST-P Accessories LDB-BE mounting LDB-BE for profile LDB-BTRA LDB-BAN LDB-P LDB-P LDB-PC LDB-PT LDB-PK LDB-PTRA LDB-BE LDB-BTRA LDB-PBTR LDB-AN-TL LDB-B-O-CLAMP LDB-U-BCLAMP LDB-W-BCLAMP LDB-BAN LDB-Z LDB-U LDB-DCB LDB-STP-AN LDB-STP-41-4-TOP LDB-STP LDB-CHTB LDB-EXT-U LDB-WP LDB-BAN-R Z-LDB GPK Channel nut SNP, SNL, SNKL Rectangular EQVS duct EQRS suspensions EQZS EQLS AMORT Threaded rod PG Mounting LDB profile LDBST Beam clamp B-CLB Console W-LDB WK-LDB Anohor TK screws TK-MO
3 Table of Contents Product Catalogue Product Type Page Product Type Page Steel screws SRS SRS KROZ Steel nuts NKS NZO Steel washer PDS Balancing AMT tape Turning vane PRQ guides for PRQ-R rectangular ducts Duct baffles WKK, WKK-OCY RURA, WKD WKT G-Clamp KLQ Flanges FLS Slide duct PWQ Screws WGO Screws WGO WGO-KL-NK, WGO-KZ-NK, WGO-IB-NK. 207 Net SIA Band clips TKS for flexible TKS-A ducts TKS-N TKSE, TKSL Sealing bands MSFK Damper KIT-DSKS mechanism KIT-DSKS-0, KIT-DSKS KIT-DS KIT-DS-H KIT-DS-M KIT-DS-PVC KIT-DS-PVC KKS Rod PRET drawn Side corners NQ for rectangular NQ-SH ducts Rectangular PQ duct profile Prefabricated CSQ-PREF, WSQ-PREF air CSQ-A-PREF, WSQ-A-PREF intake CSQ-K-PREF, WSQ-K-PREF elements Prefabricated DSQW-PREF multi-blade DSQW-A-PREF damper DSQOW-A-PREF accessories 3
4 Table of Contents Product Catalogue Product Type Page Product Type Page Ventilation NI-AKB ducts devices Exhaust valves KW KWI KW-S KWO , 254 KW, KWI, KW-S Supply air KN valves KNI , 260 KN-S KNT , 261 KN, KN-S Mounting RMI frames RMLI RM RMDL Rosettes ROZ-H ROZ-P Grilles USSE Connectors USSE-B USSE-B USSE-B USAB Grilles ULMA Round duct SGR grills SGR-DA Rectangular SHR duct grills SHR-RM Chrome-nickel KCN ventilation cap supply Square intake NCD-S diffusers PRK Plastic KPP air valve Air Intake - UELA Air Ejector UVLA USLA USAV Rectangular NKSD-C swirl cassette NKSD-CB diffusers NK-SWB NK-SWA PRW PRR Round NCD-R swirl cassette PRR-SD-R diffusers External USUA flap valve USMS-P USMS Round intake NCD diffuser PRO PRR-CD RM-NCD External USUF Grille Long range KHA nozzle 4
5 Table of Contents Product Catalogue Product Type Page Product Type Page Round supply ACL diffusers ACP ITG DKF Square supply AKP diffusers Wall air CSQ intake grill CSQ-A CSQ-A Circular SIRL silencers SIBRL SIBROL Acoustic SQLL silencers SQLL SQQL SQQL-B Attenuating BSIL bends Wall exhaust WSQ grille WSQ-A WSQ-A Flexible round AF-AL ducts AF-SN AF-AL, AF-SN Flexible SLEFL silencers SLEAL SLESD SLEAF Noise silencer SLQ Flexible duct ALAD-L ALAD ALAD-L,ALAD POAD PVC-A COM-F PVC-R-DUCT, PVC-S-DUCT Insulated ALSD-L flexible ducts ALSD-L PE ALSD ALSDL-L ALSDL-PE-L POD Flexible ducts ALAD-HY ALAD-HY-L ALID-HY ALID-HY-L Insulated SLVD-25/SLVD ventilation duct sleeve Przepustnice DARL regulacyjne DAR DARH DARL, DAR, DARH Regulating DASL dampers DASL-CV DAS DAS-CV DAS-PVC DASH Airtight DATL/DAT shut-off dampers Shut-off DAP-CV dampers DAP-CV Circular SIL silencers SIBL SIBOL Non-return DAOSL dampers DAOS
6 Table of Contents Product Catalogue Product Type Page Product Type Page Sliding GKL/GK dampers Alternating DATVTL dampers DATASL DATATL Regulating DASML, DASM dampers for servomotor Sealing TAL tapes TALK TALE TLV DUCT MET TAPV Self-adhesive GWS nails Welding nails GWZ GWZ-PI Airtight DATML, DATM dampers for servomotor Duct seal USZ, USZ-CE Alternating DATVTML dampers DATATML for servomotor Acryl SIL-AKR sealants Iris damper GBL GBLM Sealants SIL-UNI..., SIL-DEK Foams PIA-MON Steel DASQ, DASQL, DASQM, DASQML multi-blade damper Rectangular DSQ single-blade damper Firefighting SIL-PPOZ silicones Pumps PIS-POMP Galvanised DSQW rectangular multi-blade damper Aluminium DSQW-A rectangular DSQOW-A multi-blade damper Sheet OCSP elements ESLA repair spray Pressed BPKCL, BPKC cleaning BPBKCL, BPBKC bend 6
7 Table of Contents Product Catalogue Product Type Page Access doors IPR IPR -RRD IPFQ IPFQ-RD Flanges FLT Clamps FLKT End caps CPFH CSHL CPFH Product Type Page Roof ejectors HAN, HAF Roof lead-ins PDQ-AI PDQ-AII Roof CDQ-A air intake CDQ-B Roof ejector WDQ-A WDQ-B WDQ-E Roof lead-ins PD-B PD-B PD-B TAGF Air intake and BFQN exhaust bend Roof sleeves PD-EPDM-R PD-EPDM-S PD-EPDM-SO Heat and HRU-ERGO energy HRU-ERGO recovery HRU-CONTR ventilators Roof pillars COKD CQKD Heat HRE-ERGO exchangers HRE-ECCO Roof ejectors WD-C WD-C WD-D WD-E WD-G WD-B Take-off band BSAVL-90, BSAV BSILNL-135, BSILN Roof air intake CD-C CD-C Ventilation RHA caps VHK Duct fans DV Servomotors TD-04, TD-06, TA-04, TA TD TD TA-04, TA CM, LMC, LM, NM, SM, LF, NF, SF BELIMO CM24-L, 230-L LMC24A, 230A LM24A, 230A NM24A, 230A SM24, LF24, NF24A, 230A SF24A, 230A
8 Table of Contents Product Catalogue Product Type Page Product Type Page Filters UFI UFI-W F-SRT FSBQL FSBQ-I FSBQ-W FSCQ FSQ Technical ARMAFLEX insulations Rectangular QDN ducts QD Rectangular QBF bends QBFR End cap QES Pre-insulated SPRI round ducts Pre-insulated BSLI bends BSLI BSLI BSLI BSLI Pre-insulated RSCLLI reducers Rectangular QB bends QBR QBR Pre-insulated TPCLI tee-pieces Rectangular QPR reducers PR7, PRL QPR PR1, PRL Rectangular QPR setoffs QPR Pre-insulated NSLI couplings MSFI Pre-insulated CPFI end caps CSLI Rectangular TR t-pieces TR and rectangular TR crossing t-pieces TR TR CZ TR CZ TR TR TR Pre-insulated DASLI damper Round duct TR take-off
9
10 SPIRAL System Round Ventilation Ducts and Fittings We reserve the right to make changes in the dimensions and technical data products due to their continuous improvement.
11 About the System Cost-Effective Ventilation Considering how high the cost of air processing can be and how rapidly markets are growing, ventilation systems are supposed to meet high requirements. It is necessary, therefore, that ducting systems be airtight enough to keep running costs at reasonable levels. To address this issue, ALNOR Systemy Wentylacji Sp. z o.o. has developed a new comprehensive SPIRAL system. Benefits of Use Quick and easy installation Factory-installed gasket, with no loose components, ensuring proper adherence to the duct after joining. With fittings fixed tightly, no risk of leakage. Environmentally friendly, no need for silicones, which contain toxic solvents that may penetrate the duct. Installable in any weather conditions. Resistant to temperatures from -30 C to +100 C Supports negative pressures of up to 3000Pa Supports overpressures of up to 5000Pa Internal and external production control. Attractive design, so important when ducts run uncovered Airtight Ducting System SPIRAL is a well-proven system of spiral-seam quick-connect ducts and fittings with factory-installed EPDM rubber gasket. The gasket ensures a tight and permanent connection between SPIRAL system components. The system is available in a full range of sizes, from Ø80 to the largest ones, such as Ø1250mm. The SPIRAL system meets the requirements of tightness class D (certificate No. 0103/07) as defined in the PN-EN standard. The high quality and efficient, factory-installed rubber gaskets make the installation of the system easy, and thus quick. When so installed, the SPIRAL system ensures longstanding air tightness, and requires no further sealing. Key Advantage The gasket adheres closely and tightly to the duct wall.
12 Rubber Gaskets and Product Quality Control Rubber Gaskets gasket duct The gasket applied is based on homogeneous EPDM rubber. It is attached to the end of the fitting, running reliably mounted along the turned-out edge of the fitting. Such a design ensures that the gasket always remains in its place, regardless of installation conditions. The rubber gasket needs to meet high quality requirements, and this is why we have chosen EPDM rubber. This material is very resistant to ozone and UV exposure as well as varying temperatures, thus contributing to extended durability. The gasket supports temperatures ranging from - 30 C to +100 C. For ventilation systems that need to be resistant to high temperatures, the SPIRAL system can be delivered with silicone gasket that supports continuous temperatures from -70 C to +150 C and temporary temperatures from -90 C to +200 C. SPIRAL system round ducts and fittings have the hygiene certificates: a) HK/B/1652/03/2007 for those made of aluminium sheet b) HK/B/1652/01/2007 for those made of galvanised or acid-proof sheet SPIRAL system round ducts and fittings with gaskets are certified by SITAC for tightness class D certificate No. 0103/07 Testing Air Tightness All SPIRAL system components are tested for their air tightness using the following diagram. EURO VENT 2.2 diagram used for testing the air tightness of the SPIRAL system. Leak factor (l/sm2) 1,25 1,00 0,75 0,50 0,25 0, Static pressure (Pa) ALNOR overpressure test result ALNOR negative pressure test result Tightness class B Tightness class C Tightness class D All SPIRAL system components are tested for gasket quality using the following procedure. Testing the SPIRAL system gasket: Visual inspection of surface quality. It is necessary to check the internal diameter of the gasket when various s of material are used. Examination of gasket profile dimensions and of dimensions against assumed tolerances. Deformation test for simulated joining using an appliance. Gasket flexibility test for ultimate and accurate sealing. with gasket SPIRAL system are approved by SITAC on tightness class D.
13 Installation Guide Before Installation The duct should be clean before installation. Duct Cutting Ducts should be cut carefully and at an appropriate angle, and then edges should be cleared of shavings (blunted). Installation of Fittings Make sure that the ducts and fittings are not damaged. Pay particular attention to the gasket. Slip the fitting into the duct until the end stop. By turning lightly the component you will have it easier to put it into place. Attach the fitting to the duct using sheet metal screws or aircraft rivets. Listed below are the recommended thicknesses of aircraft rivets and sheet metal screws: d min. diameter number of screws , , ,0 12 Place sheet metal screws evenly across the whole circumference, making sure that the gasket is not damaged, i.e. placing them 10mm from the duct edge and the component s end stop. If the installation is unsuccessful, any rivet or screw holes should be sealed.
14 Tolerances Tolerance for Ducts diameter d nom min. - max. diameter d nommin - d nommax thickness t nom 80 80,0-80,5 0, ,0-100,5 0, ,0-112,5 0, ,0-125,5 0, ,0-140,6 0, ,0-150,6 0, ,0-160,6 0, ,0-180,7 0, ,0-200,7 0, ,0-224,8 0, ,0-250,8 0, ,0-280,9 0, ,0-300,9 0, ,0-315,9 0, ,0-356,0 0, ,0-401,0 0, ,0-451,1 0, ,0-501,1 0, ,0-561,2 0, ,0-601,2 0, ,0-631,2 0, ,0-711,5 0, ,0-801,6 0, ,0-902,0 0, ,0-1002,0 0, ,0-1122,5 0, ,0-1252,5 0, ,0-1403,0 1, ,0-1503,0 1, ,0-1603,3 1, ,0-1803,6 1, ,0-2004,0 1, ,0-2205,0 1, ,0-2406,0 1,5 Tolerance for Fittings diameter d nom Also for diameters: d2, d3, d4 min. - max. diameter d nommin - d nommax thickness t nom 80 78,8-79,3 0, ,8-99,3 0, ,5-111,3 0, ,8-124,3 0, ,7-139,3 0, ,7-149,3 0, ,7-159,3 0, ,6-179,3 0, ,6-199,3 0, ,5-223,3 0, ,5-249,3 0, ,4-279,3 0, ,4-299,3 0, ,4-314,3 0, ,3-354,3 0, ,3-399,3 0, ,2-449,3 0, ,2-499,3 0, ,1-559,3 0, ,2-599,3 0, ,1-629,3 0, ,0-709,3 0, ,0-799,3 0, ,9-899,3 0, ,9-999,3 0, ,8-1119,3 0, ,8-1249,3 0, ,3-1299,2 1, ,0-1503,0 1, ,1-1599,1 1, ,0-1799,0 1, ,8-1998,8 1, ,7-2198,7 1, ,5-2398,5 1,0
15 Tolerances and Specifications Tolerance for Fittings The SPIRAL system is based on the duct tolerances specified below. Æd e tolerance rated Angle Tolerance Material Specifications Other materials are available upon request: Acid-proof steel Aluminium Aluzinc Labelling K A AC Specify the material code when ordering. If no code is provided, standard galvanised steel quality will be supplied. Product code: BPL - A material ALNOR products are furnished with the construction industry s B sign and product codes according to their technical specifications contained in this catalogue. length tolerances L, r, r m 15 ± 3 (15; 100 ± > L (kanały) ± 0,5%
16 Ducts SPR Round spiral ducts available in diameters from 80 to 1600mm; from diameter 250mm they are provided with external ribs to increase their stiffness and resistance to negative pressure. Product code: material SPR - aaa - bbb Æd π d 2 rated πd 4 [m] [m 2 ] 80 0,251 0, ,314 0, ,393 0, ,440 0, ,471 0, ,502 0, ,565 0, ,628 0, ,703 0, ,785 0, ,879 0, ,942 0, ,989 0, ,115 0, ,256 0, ,413 0, ,570 0, ,758 0, ,884 0, ,978 0, ,229 0, ,512 0, ,826 0, ,140 0, ,517 0, ,925 1, ,396 1, ,024 2,010 ribbed
17 Ducts SPR Technical Data Pa/m [Pa/m] Pressure drop D p t [Pa] [m/s] [l/s] l/s [m 3 /h] m 3 /h 20 Volumetric flow q Negative pressure In systems with high negative pressure in relation to atmospheric pressure there is a high risk of the ventilation duct becoming deformed. Deformations usually start from the weakest points of the duct, i.e. dents occurred e.g. during transport, handling or installation. It is important therefore that the ducts and their dimensions are carefully selected depending on what the working negative pressure is projected to be like. The table below presents the maximum negative pressures allowable for specific ducts (Pa). L [m] 6 3 d t=0, t=0,6 t=0,7 t=0,9 t=1,25 ribbed ribbed ribbed ribbed ribbed
18 Bends BPL-90 BPL pressed bend, seam-welded and calibrated, with double EPDM gasket. r m» 1 x d 1 Product code: BPL - aaa - 90 Technical Data r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , ,7 Pressure drop Dp t [Pa] Volumetric flow q
19 Bends BP-90 BP pressed bend, seam-welded and calibrated, without gasket. r m» 1 x d 1 Product code: BP - aaa - 90 Technical Data r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , ,7 Pressure drop Dp t [Pa] Volumetric flow q
20 Bends BPN-90 BPN - pressed bend, seam-welded, without roller finishing and safe edges. Product code: BPN - aaa - 90 d 1 Technical Data A B r m» 1 x d 1 d 1 nom A B weight [kg] , , , , , , , , ,4 Pressure drop Dp t [Pa] Volumetric flow q
21 Bends BPNR-90 BPNR - pressed bend, seam-welded, with roller finishing and without safe edges. Product code: BPNR - aaa - 90 d 1 Technical Data r m» 1 x d 1 A B d 1 nom A B weight [kg] , , , , , , , , ,4 Pressure drop Dp t [Pa] Volumetric flow q
22 Bends BPKL/BPKFL-90 BPKL - pressed short bend, seam-welded, with biddings, safe edges and EPDM gasket BPKFL pressed short bend female - male, seam-welded, with biddings, safe edges and EPDM gasket. Ideal for valve mounting frames RM and RML. Pressed bends requires less installation space. BPKL r m» 0,6 x d 1 BPKFL e L L Product code: BPKL - aaa - 90 d 1 r m» 0,6 x d 1 e d 1 nom L e weight [kg] Technical Data Pressure drop Dp t [Pa] , , , , , , [l/s] [m ³ /h]
23 Bends BPK/BPKF-90 BPK - pressed short bend, seam-welded, without biddings and safe edges BPKF pressed short bend female - male, seam-welded, with biddings and safe edges. Ideal for valve mounting frames RM and RML. Pressed bends requires less installation space. BPK r m» 0,6 x d 1 BPKF e L L Product code: BPK - aaa - 90 d 1 r m» 0,6 x d 1 e Technical Data Pressure drop Dp t [Pa] d 1 nom L e weight [kg] , , , , , , [l/s] [m ³ /h]
24 Bends BSL-90 BSL segmented bend with double EPDM gasket. r m» 1 x d 1 Product code: BSL - aaa - 90 Technical Data Pressure drop Dp t [Pa] Volumetric flow q r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,60
25 Bends BS-90 BS segmented bend without gasket. r m» 1 x d 1 Product code: BS - aaa - 90 Technical Data Pressure drop Dp t [Pa] Volumetric flow q r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,60
26 Bends BSKL-90 BSKL - short segmented bend with double EPDM gasket. r m» 0,6 x d 1 Product code: BSKL - aaa - 90 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , , , ,10
27 Bends BSK-90 r m» 0,6 x d 1 L weight nom [kg] , ,70 BSK short segmented bend without gasket ,90 r m» 0,6 x d 1 Product code: BSK - aaa , , , , , , , , , , , , , , , , , , , , ,10
28 Bends BSDL/BSD-90 BPDL segmented bend with double EPDM gasket. BSD segmented bend without gasket. Bends with elbow radius available upon request. r m ³ 2d 1 Product code: BSDL - aaa - 90 Technical Data Pressure drop Dp t [Pa] r m» 1,5 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , ,3 Volumetric flow q
29 Bends BPL/BP-60 BPL pressed bend, seam-welded and calibrated, with double EPDM gasket. BP pressed bend, seam-welded and calibrated, without gasket. Product code: BPL - aaa - 60 Technical Data r m» 1 x d 1 L weight rated [kg] , , , , , , , , , ,2 Pressure drop Dp t [Pa] Volumetric flow q
30 Bends BSL/BS-60 BSL segmented bend with double EPDM gasket. BS segmented bend without gasket. Product code: BSL - aaa - 60 Technical Data Pressure drop Dp t [Pa] Volumetric flow q r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,40
31 Bends BSKL-60 BSKL short segmented bend with double EPDM gasket. r m» 0,6 x d 1 Product code: BSKL - aaa - 60 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,40
32 Bends BSK-60 BSK short segmented bend without gasket. r m» 0,6 x d 1 Product code: BSK - aaa - 60 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,40
33 Bends BPL-45 BPL pressed bend. Seam-welded and calibrated with double EPDM gasket. Product code: BPL - aaa - 45 Technical Data r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , ,8 Pressure drop Dp t [Pa] Volumetric flow q
34 Bends BP-45 BP pressed bend, seam-welded and calibrated, without gasket. Product code: BP - aaa - 45 Technical Data r m» 1 x d 1 L weight rated , , , , , , , , , , ,8 Pressure drop Dp t [Pa] Volumetric flow q
35 Bends BPN-45 BPN pressed bend, seam-welded, without biddings and safe edges Product code: BPN - aaa - 45 d 1 Technical Data r m» 1 x d 1 d 1 nom B A B A weight [kg] , , , , , , , , ,3 Pressure drop Dp t [Pa] Volumetric flow q
36 Bends BPNR-45 BPNR pressed bend, seam-welded, without safe edges Product code: BPNR - aaa - 45 d 1 Technical Data r m» 1 x d 1 d 1 nom B A B A weight [kg] , , , , , , , , ,3 Pressure drop Dp t [Pa] Volumetric flow q
37 Bends BPKL/BPKFL-45 BPKL - pressed short bend, seam-welded, with biddings, safe edges and EPDM gasket BPKFL pressed short bend female - male, seam-welded, with biddings, safe edges and EPDM gasket. Ideal for valve mounting frames RM and RML. Pressed bends requires less installation space. BPKL r m» 0,6 x d 1 BPKFL e L L Product code: BPKL - aaa - 45 e d 1 r m» 0,6 x d 1 d 1 L e weight nom [kg] , , , , , ,5
38 Bends BPK/BPKF-45 BPK - pressed short bend, seam-welded, without biddings and safe edges BPKF pressed short bend female - male, seam-welded, with biddings and safe edges. Ideal for valve mounting frames RM and RML. Pressed bends requires less installation space. BPK r m» 0,6 x d 1 BPKF e L L Product code: BPK - aaa - 45 e d 1 r m» 0,6 x d 1 d 1 nom L e weight [kg] , , , , , ,5
39 Bends BSL-45 BSL segmented bend with double EPDM gasket. Product code: BSL - aaa - 45 Technical Data Pressure drop Dp t [Pa] Volumetric flow q r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,40
40 Bends BS-45 BS segmented bend without gasket. Product code: BS - aaa - 45 Technical Data Pressure drop Dp t [Pa] Volumetric flow q r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,40
41 Bends BSKL-45 BSKL short segmented bend with double EPDM gasket. r m» 0,6 x d 1 Product code: BSKL - aaa - 45 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,80
42 Bends BSK-45 BSK short segmented bend without gasket.. r m» 0,6 x d 1 Product code: BSK - aaa - 45 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,80
43 Bends BPL/BP-30 BPL pressed bend, seam-welded and calibrated, with double EPDM gasket. BP pressed bend, seam-welded and calibrated, without gasket. Product code: BPL - aaa - 30 Technical Data r m» 1 x d 1 L weight rated [kg] , , , , , , , , , ,4 Pressure drop Dp t [Pa] Volumetric flow q
44 Bends BSL/BS-30 BSL segmented bend with double EPDM gasket. BS segmented bend without gasket. Product code: BSL - aaa - 30 Technical Data Pressure drop Dp t [Pa] r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,30 Volumetric flow q
45 Bends BSKL-30 BSK L short segmented bend with double EPDM gasket. r m» 0,6 x d 1 r m» 0,6 x d 1 L weight nom [kg] , , , ,70 Product code: BSKL - aaa , , , , , , , , , , , , , , , , , ,90
46 Bends BSK-30 BSK short segmented bend without gasket. r m» 0,6 x d 1 Product code: BSK - aaa - 30 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,90
47 Bends BPL/BP-15 BPL pressed bend, seam-welded and calibrated, with double EPDM gasket. BP pressed bend, seam-welded and calibrated, without gasket. Product code: BPL - aaa - 15 r m» 1 x d 1 L weight rated [kg] , , , , , , , , ,6 Technical Data Pressure drop Dp t [Pa] Volumetric flow q
48 Bends BSL/BS-15 BSL segmented bend with double EPDM gasket. BS segmented bend without gasket. Assembled from segments Product code: BSL - aaa - 15 Technical Data Pressure drop Dp t [Pa] r m» 1 x d 1 L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , ,10 Volumetric flow q
49 Bends BSKL-15 BSKL short segmented bend with double EPDM gasket. r m» 0,6 x d 1 Product code: BSKL - aaa - 15 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,50
50 Bends BSK-15 BSK short segmented bend without gasket. r m» 0,6 x d 1 Product code: BSK - aaa - 15 r m» 0,6 x d 1 L weight nom [kg] , , , , , , , , , , , , , , , , , , , , , ,50
51 Pressed male reducers RPCL RPCL Pressed symmetric male-male reducer with EPDM gaskets. and Æd 2 fits SPR ducts. Product code: Æd 2 RPCL - aaa - bbb Æd 2 L weight rated rated [kg] , , , * 30 0,20 125* 30 0, , , , , , * 40 0,30 140* 30 0,30 150* 30 0,30 160* 30 0, , , , , , , * 50 0,40 160* 50 0,40 180* 30 0,40 200* 30 0, , , ,50 180* 50 0, ,60
52 Pressed male reducers RPCL Æd 2 L weight rated rated [kg] 224* 50 0, * 80 0,60 180* 70 0,60 200* 60 0,60 224* 40 0, * 70 0,70 224* 60 0,70 250* 30 0,60 280* 30 0, ,80 180* 90 0, ,70 224* 60 0, ,70 280* 40 0,70 300* 38 0, * 110 1,10 224* 90 1,00 250* 70 1,00 315* 30 0, * 140 1,50 224* 120 1,40 250* 100 1,30 315* 60 1,30 355* 30 1, * 140 2,00 280* 110 1,90 300* 100 1,90 315* 90 1,80 355* 60 1,70 400* 40 1, * 128 2,20 300* 140 2,40 315* 120 2,20 355* 100 2,20 400* 70 2,10 450* 40 2, * 170 2,90 355* 140 2,80 400* 110 2,70 * Fabricated, the remaining entirely pressed. Æd 2 L weight rated rated [kg] 450* 80 2,60 500* 75 2, * 130 3,10 450* 100 3,00 500* 70 2,70 560* 30 2, * 160 3,20 400* 140 3,30 450* 120 3,30 500* 80 3,00 560* 75 2,90 600* 30 2,50
53 Pressed male reducers RPC RPC Pressed symmetric male-male reducer without gasket. and Æd 2 fits SPR ducts. Product code: Æd 2 RPC - aaa - bbb Æd 2 L weight rated rated [kg] , , , * 30 0,20 125* 30 0, , , , , , * 40 0,30 140* 30 0,30 150* 30 0,30 160* 30 0, , , , , , , * 50 0,40 160* 50 0,40 180* 30 0,40 200* 30 0, , , ,50 180* 50 0,40
54 Pressed male reducers RPC Æd 2 L weight rated rated [kg] ,60 224* 50 0, * 80 0,60 180* 70 0,60 200* 60 0,60 224* 40 0, * 70 0,70 224* 60 0,70 250* 30 0,60 280* 30 0, ,80 180* 90 0, ,70 224* 60 0, ,70 280* 40 0,70 300* 38 0, * 110 1,10 224* 90 1,00 250* 70 1,00 315* 30 0, * 140 1,50 224* 120 1,40 250* 100 1,30 315* 60 1,30 355* 30 1, * 140 2,00 280* 110 1,90 300* 100 1,90 315* 90 1,80 355* 60 1,70 400* 40 1, * 128 2,20 300* 140 2,40 315* 120 2,20 355* 100 2,20 400* 70 2,10 450* 40 2, * 170 2,90 355* 140 2,80 400* 110 2,70 * Fabricated, the remaining entirely pressed. Æd 2 L weight rated rated [kg] 450* 80 2,60 500* 75 2, * 130 3,10 450* 100 3,00 500* 70 2,70 560* 30 2, * 160 3,20 400* 140 3,30 450* 120 3,30 500* 80 3,00 560* 75 2,90 600* 30 2,50
55 Pressed nipple reducers RPCN RPCN- symmetric pressed "nipple-nipple" reducer, without roller finishing and safe edges. Ød1 and Ød2 fits to the SPR duct Product code typ d 1 d 2 RPCN - aaa - bbb d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , ,6
56 Pressed nipple reducers RPCNR RPCNR - symmetric pressed "nipple-nipple" reducer, with roller finishing and whitout safe edges. Ød1 and Ød2 - fits to the SPR duct Product code typ d 1 d 2 RPCN R - aaa - bbb d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , ,6
57 Pressed female reducers RPCFL RPCFL Pressed symmetric female-male reducer with EPDM gasket. coupling slips directly over SPIRAL system fittings. Æd 2 fits SPR ducts. Product code: Æd 2 RCFPL - aaa - bbb Æ d 2 L weight rated rated [kg] , , , * 30 0,20 125* 30 0, , , , , , * 40 0,30 140* 30 0,30 150* 30 0,30 160* 30 0, , , , , , , * 50 0,40 160* 50 0,40 180* 30 0,40 200* 30 0, , , ,50 180* 50 0, ,60 224* 50 0,40
58 Pressed female reducers RPCFL Æd 2 L weight rated rated [kg] * 80 0,60 180* 70 0,60 200* 60 0,60 224* 40 0,60 250* 30 0, * 70 0,70 224* 60 0,70 250* 30 0,60 280* 30 0, ,80 180* 90 0, ,70 224* 60 0, ,70 280* 30 0,70 300* 30 0, * 110 1,10 224* 90 1,10 250* 70 1,00 315* 30 0, * 140 1,50 224* 120 1,40 250* 100 1,30 315* 60 1,30 355* 30 1, * 140 2,00 280* 110 1,90 300* 100 2,00 315* 90 2,00 355* 60 1,80 400* 40 0, * 208 2,20 300* 140 2,40 315* 120 2,30 355* 100 2,20 400* 70 2,20 450* 40 2, * 170 2,90 355* 140 2,80 400* 110 2,70 450* 80 2,60 Æd 2 L weight rated rated [kg] * Fabricated, the remaining entirely pressed. 500* 75 2, * 130 3,10 450* 100 3,00 500* 70 2,80 560* 30 2,40 400* 140 3,30 450* 120 3,30 500* 80 3,00 560* 75 2,90 600* 30 2,50
59 Pressed female reducers RPCF RPCF Pressed symmetric female-male reducer without gasket. coupling slips directly over SPIRAL system fittings. Æd 2 fits SPR ducts. Product code: Æd 2 RPCF - aaa - bbb Æd 2 L weight rated rated [kg] , , , * 30 0,20 125* 30 0, , , , , , * 40 0,30 140* 30 0,30 150* 30 0,30 160* 30 0, , , , , , , * 50 0,40 160* 50 0,40 180* 30 0,40 200* 30 0, , , ,50 180* 50 0, ,60 224* 50 0,40
60 Pressed female reducers RPCF Æd 2 L weight rated rated [kg] * 80 0,60 180* 70 0,60 200* 60 0,60 224* 40 0,60 250* 30 0, * 70 0,70 224* 60 0,70 250* 30 0,60 280* 30 0, ,80 180* 90 0, ,70 224* 60 0, ,70 280* 30 0,70 300* 30 0, * 110 1,10 224* 90 1,10 250* 70 1,00 315* 30 0, * 140 1,50 224* 120 1,40 250* 100 1,30 315* 60 1,30 355* 30 1, * 140 2,00 280* 110 1,90 300* 100 2,00 315* 90 2,00 355* 60 1,80 400* 40 0, * 208 2,20 300* 140 2,40 315* 120 2,30 355* 100 2,20 400* 70 2,20 450* 40 2, * 170 2,90 355* 140 2,80 400* 110 2,70 450* 80 2,60 Æd 2 L weight rated rated [kg] * Fabricated, the remaining entirely pressed. 500* 75 2, * 130 3,10 450* 100 3,00 500* 70 2,80 560* 30 2,40 400* 140 3,30 450* 120 3,30 500* 80 3,00 560* 75 2,90 600* 30 2,50
61 Pressed reducers RPCL/RPCFL/RPC/RPCF Technical Data Pressure drop Dp t [Pa] reduction stage , [l/s] l/s Volumetric flow q [m m 3 /h 3 /h] 2 reduction stage [Pa] Pressure drop Dp t [l/s] l/s Volumetric flow q [m m 3 3 /h] /h
62 Pressed reducers RPCL/RPCFL/RPC/RPCF/RPCN/RPCNR Technical Data Pressure drop Dp t [Pa] reduction stage [l/s] l/s Volumetric flow q [m 3 /h] m 3 /h 1 reduction stage [Pa] Pressure drop Dp t , [l/s] l/s Volumetric flow q [mm 3 /h] 3 /h
63 Pressed reducers RPCL/RPCFL/RPC/RPCF/RPCN/RPCNR Technical Data Pressure drop Dp t [Pa] reduction stage , [l/s] l/s [m 3 m/h] 3 /h Volumetric flow q 3 reduction stage [Pa] Pressure drop Dp t , [l/s] l/s [m 3 /h] m 3 /h Volumetric flow q
64 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF RSCLL symmetric reducer with male-male coupling and EPDM gaskets. RSLL asymmetric reducer with male-male coupling and EPDM gaskets. RSCFL symmetric reducer with female-male coupling and EPDM gasket. RSLFL asymmetric reducer with female-male coupling and EPDM gasket. RSCL symmetric reducer with male-male coupling, without gasket. RSL asymmetric reducer with male-male coupling, without gasket. RSCLF symmetric reducer with female-male coupling, without gasket. RSLF asymmetric reducer with female-male coupling, without gasket. Æd 2 fits SPR ducts. fits SPR ducts or slips directly over fittings. Technical Data Product code: RSLL - aaa - bbb Æd 2
65 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF Æd 2 L weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,65 Æd 2 L weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,00
66 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF Æd 2 L weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,70 Æd 2 L weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,70
67 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF Æd 2 L weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,1
68 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF Technical Data Pressure drop Dp t [Pa] Pa ,5 1 reduction stage [l/s] l/s [m 3 /h] m 3 /h Volumetric flow q 2 reduction stage Pa [Pa] Pressure drop Dp t , [l/s] l/s [m 3 /h] m 3 /h Volumetric flow q
69 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF Technical Data Pressure drop Dp t Pa [Pa] ,5 3 reduction stage [l/s] l/s [m 3 m/h] 3 /h Volumetric flow q 1 reduction stage [Pa] Pressure drop Dp t , [l/s] l/s [m 3 /h] m 3 /h Volumetric flow q
70 Fabricated reducers RSCLL/RSLL/RSCLFL/RSLFL/RSCL/RSL/RSCLF/RSLF Technical Data Pressure drop Dp t [Pa] ,5 2 reduction stage [l/s] l/s [m m 3 /h 3 /h] Volumetric flow q 3 reduction stage Pa [Pa] Pressure drop Dp t , [l/s] l/s [m m 3 3 /h] /h Volumetric flow q
71 Segment flat reductions RSFC/RSFCF/RSFCL/RSFCFL/RSF/RSFF/RSFL/RSFFL RSFC symetric flat segment reduction nipple-nipple, RSFCF symetric flat segment reduction muff-nipple, RSFCL symetric flat segment reduction nipple-nipple with the EPDM rubber gasket, RSFCFL flat symetric segment reduction muff-nipple with the EPDM rubber gasket, RSF flat asymetric segment reduction nipple-nipple, RSFF flat asymetric segment reduction muff-nipple, RSFL flat asymetric segment reduction nipple-nipple with the EPDM rubber gasket, RSFFL flat asymetric segment reduction muff-nipple with the EPDM rubber gasket, d 2 matches the SPR duct, d 1 Product code: d 1 d 2 RSFC - aaa - bbb d 1 nom c d 2 nom c L L weight [kg] , ,5 5 0, , , ,5 5 0, , , , ,5 5 0, ,5 5 0, ,5 5 0, ,5 5 0, ,5 5 0, ,5 5 0, ,5 5 0, ,5 5 0, , ,5 5 0, , , , , , , , , , , , ,6
72 Segment flat reductions RSFC/RSFCF/RSFCL/RSFCFL/RSF/RSFF/RSFL/RSFFL d 1 nom d 2 nom c L weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , ,1
73 Pressed pressed saddles SPL SPL pressed saddle with aerodynamic flow radius facing the branch, with EPDM gasket. Product code: Æd 3 SPL - aaa - bbb Æd 3 r H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , ,
74 Pressed collar saddles SPL Æd 3 r H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , ,7
75 Pressed collar saddles SP SP pressed saddle with aerodynamic flow radius facing the branch, without gasket. Product code: Æd 3 SP - aaa - bbb Æd 3 r H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , ,
76 Pressed collar saddles SP Æd 3 r H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , ,7
77 Pressed collar saddles SPSL SPSL segment saddle with EPDM gasket Product code: d 1 d 3 SPSL - aaa - bbb d 1 nom d 3 nom H weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,80
78 Pressed collar saddles SPSL d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,32 d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,70
79 Pressed collar saddles SPSL d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , , ,20
80 Pressed collar saddles SPS SPS segment saddle without EPDM gasket Product code: d 1 d 3 SPS - aaa - bbb d 1 nom d 3 nom H weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,80
81 Pressed collar saddles SPS d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,32 d 1 nom d 2 nom L weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,70
82 Pressed collar saddles SPS d 1 nom d 2 nom L weigth [kg] , , , , , , , , , , , , , , , , , , , , ,20
83 Pressed saddles SSCL/SSL/SSC/SS SSCL symmetric pressed saddles with EPDM gasket. SSL asymmetric pressed saddles with EPDM gasket. SSC symmetric pressed saddles without gasket. SS asymmetric pressed saddles without gasket. Angled at 90, designed for installation in the round duct. Product code: SSL - aaa - bbb Æd Æd 2 SSL SSCL Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , ,70
84 Pressed saddles SSCL/SSL/SSC/SS Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,00 Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,60
85 Pressed saddles SSCL/SSL/SSC/SS Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,40 Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,30
86 Pressed saddles SSCL/SSL/SSC/SS Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,7 Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,2
87 Pressed saddles SSCL/SSL/SSC/SS Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,7 Æd Æd 3 L H weight rated rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,2
88 Saddle tee SSCCB The SSCCB saddle tee. Asymmetric, shaped at 90 angle, designed for mounting on a round duct. Æd H nom nom Product code: SSCCB - aaa - bbb Æd
89 Saddle tee SSCCB Æd H nom nom Æd H nom nom
90 Saddle tee SSCCBL SSCCBL Saddle tee with the rubber gasket EPDM Asymmetric, shaped under 90 angle with a round outlet, designed for mounting on a rectangular duct. Product code: SSCCBL - aaa - bbb Æd 2 Æd H nom nom
91 Saddle tee SSCCBL Æd H nom nom Æd H nom nom
92 Saddle tee SSCFB SSCFB saddle tee Asymetric, shaped under 90 angle with a round outlet, designed for mounting on a rectangular ventilation duct. Æd H nom Product code: SSCFB - aaa - bbb Æd
93 Saddle tee SSCFBL SSCFBL Saddle tee with the rubber gasket EPDM Asymmetric, shaped under 90 angle with a round outlet, designed for mounting on a rectangular duct. Product code: SSCFBL - aaa - bbb Æd 2 Æd H nom
94 Lateral pressed saddles SSCVL/SSCV-45 SSCVL-45 lateral pressed saddles, with EPDM gasket. SSCV-45 - lateral pressed saddles, without gasket. Angled at 45, designed for installation in the round duct. Different angles from 30 to 80 available. Product code: SSCVL/SSCV-45 - aaa - bbb Æd Æd 2 o Æd 3 weight rated [kg] 80 0, , , , , , , , , , , , , , , , , , , , , , , , , ,0 3 * dimension L 2 as shown in the tables on pages page page 116 for the TSVL component
95 T-pieces TPCL/XPCL TPCL assembled T-pieces with pressed SPL saddle and EPDM gasket. T-pieces with diametres: 100x100, 125x125, 160x160, 200x200 are full pressed. XPCL assembled X-pieces with Pressed SPL saddle and EPDM gasket. TPCL XPCL Æd 4 cen be different from Æd 3 Product code: Æd 3 Æd 4 XPCL - aaa - bbb - ccc Æd 3 /Æd 4 L H TPCL XPCL weight [kg] ,30 0, ,33 0, ,45 0, ,40 0, ,50 0, ,63 0, ,43 0, ,60 0, ,70 1, ,45 0, ,64 0, ,74 1, ,75 1, ,75 1, ,50 0, ,63 0, ,75 1, ,75 1, ,77 1, ,85 1, ,66 0, ,78 0, ,85 1, ,90 1, ,98 1, ,00 1,30
96 T-pieces TPCL/XPCL Æd 3 /Æd 4 L H TPCL XPCL weight [kg] ,20 1, ,73 0, ,85 0, ,93 1, ,94 1, ,96 1, ,05 1, ,20 1, ,28 1, ,75 0, ,88 1, ,06 1, ,16 1, ,16 1, ,25 1, ,40 1, ,53 1, ,65 2, ,93 1, ,07 1, ,20 1, ,38 1, ,38 1, ,46 1, ,70 2, ,72 2, ,95 2, ,00 2, ,05 1, ,15 1, ,32 1, ,50 1, ,52 1, ,60 1, ,80 2, ,86 2, ,05 2, ,20 1, ,25 1, ,40 1, ,60 1,80 Æd 3 /Æd 4 L H TPCL XPCL weight [kg] ,60 1, ,62 2, ,96 2, ,98 2, ,05 2, ,20 2, ,25 1, ,30 1, ,46 1, ,65 1, ,68 1, ,70 2, ,05 2, ,08 2, ,20 2, ,30 2, ,80 3, ,70 1, ,90 2, ,15 2, ,55 2, ,82 3, ,90 3, ,40 4, ,15 2, ,40 2, ,70 2, ,00 3, ,40 3, ,50 3, ,95 4, ,00 6, ,30 3, ,70 3, ,10 4, ,50 4, ,10 5, ,20 6, ,80 3, ,10 4, ,50 4,70
97 T-pieces TPCL/XPCL Æd 3 /Æd 4 L H TPCL XPCL weight [kg] ,0 5, ,6 6, ,9 7, ,6 5, ,1 6, ,9 7, ,6 9, ,0 6, ,3 6, ,5 7, ,2 9, ,3 6, ,7 6, ,0 8, ,5 10, ,5 6, ,0 6, ,6 6, ,5 8, ,5 9, ,4 10, ,2 6, ,8 7, ,4 8, ,4 9, ,5 10, ,5 11, ,2 12, ,9 13,1 1 made of pressed saddles SPL 2 made of two parts fully pressed 3 made of pressed saddles SPPL 4 made of segment saddles SPSL
98 T-pieces TPC/XPC TPC t-piece built with SP saddle, without gasket. XPC x-piece built with SP saddles, without gasket Æd 4 may differ from Æd 3 Product code: Æd 2 Æd 3 TPC XPC TPC - aaa - bbb - ccc Æd 3 /Æd 4 L H TPC XPC weight [kg] ,25 0, ,30 0, ,40 0, ,36 0, ,46 0, ,58 0, ,38 0, ,50 0, ,65 0, ,42 0, ,55 0, ,68 0, ,70 0, ,70 1, ,44 0, ,55 0, ,68 1, ,75 1, ,75 1, ,80 1, ,50 0, ,65 0, ,77 1, ,80 1, ,80 1, ,92 1,14
99 T-pieces TPC/XPC Æd 3 /Æd 4 L H TPC XPC weight [kg] ,06 1, ,55 0, ,65 0, ,79 1, ,83 1, ,88 1, ,95 1, ,15 1, ,25 1, ,60 0, ,78 0, ,90 1, ,98 1, ,98 1, ,00 1, ,20 1, ,25 1, ,46 2, ,73 0, ,83 1, ,90 1, ,12 1, ,12 1, ,19 1, ,40 2, ,40 2, ,60 2, ,77 2, ,80 1, ,93 1, ,05 1, ,20 1, ,20 1, ,28 1, ,45 2, ,50 2, ,64 2, ,90 1, ,00 1, ,07 1, ,25 1,77 Æd 3 /Æd 4 L H TPCL XPCL weight [kg] ,25 1, ,35 1, ,55 2, ,58 2, ,73 2, ,94 2, ,00 1, ,02 1, ,10 1, ,35 1, ,35 1, ,35 2, ,62 2, ,65 2, ,80 2, ,95 2, ,80 3, ,32 2, ,45 2, ,70 2, ,10 2, ,36 3, ,45 3, ,10 4, ,80 2, ,90 2, ,20 2, ,60 3, ,80 3, ,00 3, ,55 4, ,60 5, ,65 3, ,00 3, ,50 4, ,00 4, ,50 5, ,60 6, ,00 3, ,30 4, ,80 4,60
100 T-pieces TPC/XPC Æd 3 /Æd 4 L H TPCL XPCL weight [kg] ,4 5, ,0 5, ,3 7, ,3 5, ,8 6, ,6 7, ,9 9, ,5 6, ,9 6, ,9 7, ,3 9, ,8 6, ,4 7, ,3 8, ,7 10, ,5 6, ,0 6, ,6 6, ,5 8, ,5 9, ,4 10, ,2 6, ,8 7, ,4 8, ,4 9, ,5 10, ,5 11, ,2 12, ,9 13,1 1 made of pressed saddles SP 2 made of two parts fully pressed 3 made of pressed saddles SPP 4 made of segment saddles SPS
101 Reducing t-pieces blinded TPCL-CP-R/TPC-CP-R TPC-CP-R reduce t-piece without EPDM TPCL-CP-R reduce t-piece with EPDM For d reduce t-piece with end cap CP. For d reduce t-piece with end cap CPF. Product code: TPCL-CP-R - aaa - bbb - ccc L d 1 TPCL-CP-R Ød2 Ød1 d 2 Ød3 L d 3 TPC-CP-R Ød2 Ød1 L weigth [kg] , , , , , ,35 Ød3 typ Æd 2 Æd 3
102 Reducing t-pieces blinded TPC-CP-R-I/TPCL-CP-R-I TPC-CP-R-I isolated reduce t-piece without EPDM TPCL-CP-R-I isolated reduce t-piece with EPDM For d reduce t-piece with end cap CP. For d reduce t-piece with end cap CPF. Product code TPC-CP-R - aaa - bbb - ccc L d 1 TPCL-CP-R-I Ød2 Ød1 d 2 Ød3 L d 3 TPC-CP-R-I Ød2 Ød1 L weight [kg] , , , , , ,45 Ød3 typ Æd 2 Æd 3
103 T-pieces TSCL/TSL/XSCL/XSL/TSC/TS/XSC/XS TSCL XSCL TSC XSC TSCL symmetric T-piece with EPDM gaskets. XSCL symmetric X-pieces with EPDM gasket. TSC symmetric T-piece without gasket. XSC symmetric X-pieces without gasket. TSL asymmetric T-piece with EPDM gaskets. XSL asymmetric X-pieces with EPDM gaskets. TS asymmetric T-piece without gasket. XS asymmetric X-pieces without gasket. XSCL/XSL Æd 4 may differ from Æd 3. To be installed with SSCL/SSL Product code: TSCL - aaa - bbb Æd 3
104 T-pieces TSCL/TSL/XSCL/XSL/TSC/TS/XSC/XS Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,70 0, ,80 0, ,85 1, ,90 1, ,95 1, ,95 1, ,15 1, ,25 1, ,40 2, ,80 0, ,90 1, ,95 1, ,00 1, ,05 1, ,10 1, ,25 1, ,35 1, ,50 2, ,70 2, ,90 1, ,95 1, ,00 1, ,00 1, ,10 1, ,15 1, ,35 1, ,45 1, ,60 2, ,80 2, ,90 2, ,00 2, ,00 1, ,05 1, ,15 1, ,20 1, ,25 1, ,30 1, ,50 1, ,60 1, ,80 2, ,00 2,60 Æd 3 /Æd 4 L H TSCL/TSL XSCL/XL weight [kg] ,10 2, ,20 3, ,90 4, ,20 1, ,30 1, ,40 1, ,40 1, ,50 1, ,50 1, ,70 2, ,85 2, ,00 2, ,30 2, ,40 3, ,50 3, ,20 4, ,60 5, ,30 1, ,40 1, ,50 1, ,55 1, ,60 1, ,70 1, ,90 2, ,00 2, ,20 2, ,50 2, ,55 3, ,65 3, ,50 4, ,90 5, ,10 8, ,40 1, ,50 1, ,60 1, ,70 1, ,75 1, ,80 2, ,00 2, ,20 2, ,30 2,70
105 T-pieces TSCL/TSL/XSCL/XSL/TSC/TS/XSC/XS Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,6 3, ,7 3, ,8 3, ,7 4, ,1 5, ,4 8, ,3 1, ,5 1, ,6 1, ,7 1, ,7 1, ,8 1, ,9 2, ,1 2, ,3 2, ,5 2, ,7 3, ,8 3, ,9 3, ,8 4, ,2 5, ,6 8, ,2 9, ,0 2, ,2 2, ,3 2, ,4 2, ,5 2, ,6 2, ,8 3, ,0 3, ,3 3, ,5 3, ,7 4, ,8 4, ,4 5, ,8 5, ,3 8, ,8 9, ,5 11, ,5 2,6 Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,7 2, ,8 2, ,9 3, ,0 3, ,1 3, ,4 3, ,6 3, ,8 4, ,2 4, ,4 4, ,5 4, ,0 5, ,5 6, ,1 8, ,6 9, ,3 11, ,7 12, ,0 13, ,7 3, ,9 4, ,0 4, ,1 4, ,3 4, ,7 4, ,0 5, ,3 5, ,7 6, ,0 6, ,1 6, ,8 7, ,4 8, ,0 9, ,7 10, ,4 11, ,8 13, ,1 13, ,5 17, ,1 4, ,4 4, ,5 4, ,55 4,7
106 T-pieces TSCL/TSL/XSCL/XSL/TSC/TS/XSC/XS Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,7 4, ,3 5, ,5 5, ,8 6, ,4 6, ,6 6, ,7 7, ,5 8, ,0 8, ,7 9, ,4 10, ,1 12, ,6 13, ,0 14, ,5 20, ,9 24, ,8 6, ,1 6, ,5 6, ,0 7, ,3 7, ,4 7, ,2 8, ,8 9, ,6 10, ,3 11, ,1 12, ,6 13, ,0 14, ,7 20, ,2 24, ,1 29, ,2 6, ,5 6, ,9 7, ,5 7, ,8 8, ,9 8, ,8 9, ,4 10, ,2 11,0 Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,9 11, ,7 12, ,3 13, ,6 14, ,5 20, ,0 24, ,0 28, ,5 6, ,8 7, ,2 7, ,8 8, ,1 8, ,3 8, ,2 9, ,8 10, ,6 11, ,4 12, ,3 13, ,7 14, ,2 14, ,2 20, ,8 24, ,7 28, ,0 34, ,6 10, ,1 11, ,8 12, ,0 12, ,1 13, ,0 14, ,0 15, ,0 16, ,0 18, ,7 18, ,2 19, ,3 22, ,0 25, ,1 30, ,4 36, ,7 47, ,9 12,2
107 T-pieces TSCL/TSL/XSCL/XSL/TSC/TS/XSC/XS Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,8 13, ,2 13, ,5 13, ,7 15, ,6 16, ,7 17, ,8 18, ,9 19, ,7 20, ,2 21, ,4 24, ,2 26, ,5 30, ,9 36, ,6 47, ,9 56, ,1 15, ,4 16, ,4 17, ,6 19, ,8 20, ,1 21, ,8 22, ,5 23, ,8 26, ,7 28, ,2 31, ,8 36, ,8 47, ,4 55, ,4 17, ,9 19, ,0 20, ,2 21, ,6 23, ,0 24, ,8 25, ,5 26, ,0 29, ,0 31, ,5 34,1 Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL - weight [kg] ,3 37, ,8 47, ,6 56, ,9 28, ,5 30, ,6 31, ,4 31, ,3 35, ,7 37, ,7 40, ,9 44, ,7 48, ,7 57, ,0 31, ,8 33, ,0 34, ,9 35, ,0 38, ,7 41, ,7 44, ,3 48, ,4 53, ,6 57, ,5 67, ,9 75, ,4 83, ,9 38, ,9 39, ,2 42, ,3 45, ,6 49, ,7 53, ,2 58, ,7 62, ,0 67, ,5 75, ,0 83, ,6 41, ,1 45, ,3 48, ,9 52,1
108 T-pieces TSCL/TSL/XSCL/XSL/TSC/TS/XSC/XS Æd 3 /Æd 4 L H TSCL/TSL XSCL/XSL weight [kg] ,2 56, ,9 61, ,6 66, ,1 71, ,8 75, ,7 83, ,0 48, ,4 51, ,2 55, ,8 59, ,5 65, ,6 69, ,4 75, ,3 79, ,3 83,1
109 T-pieces TPCL/XPCL/TPC/XPC Technical Data Æd 3 Pressure drop Dp t [Pa] Speed V 3 [m/s] Speed V 1 [m/s] [Pa] Æd 2 Pressure drop Dp t V 1 V 2 <1 6 8 V2 [m/s] V 1 V 2 > 1 4 V2 [m/s] The figure also applies to reducers with diameter Æd [m/s] Speed V 1 V 1 average speed in d 1 V 2 average speed in d 2 V 3 average speed in d 3
110 T-pieces TPCL/XPCL/TPC/XPC Technical Data Æd 3 Æd 2 Pressure drop Dp t [Pa] Speed V 2 = V 1 V 3 [m/s] [m/s] [Pa] 100 Æd 3 Æd 2 Pressure drop Dp t V 2 [m/s] [m/s] Speed V 3 V 1 average speed in d 1 V 2 average speed in d 2 V 3 average speed in d 3
111 T-pieces TPCL/XPCL/TPC/XPC Technical Data Æd 2 Pressure drop Dp t [Pa] V 1 V 2 <1 4 6 V 1 [m/s] V1 [m/s] 1 V 1 V 2 > [m/s] Speed 8 V The figure also applies to reducers with diameter Æd Pressure drop Dp t Velocity V 3 [m/s] [m/s] Speed V 1 V 1 average speed in d 1 V 2 average speed in d 2 V 3 average speed in d 3
112 Tees and four-ways pieces COLL COLL tees are always produced with 125 mm laterals. Maximal number of laterals in these tees is 3. COLL tee is made of galvanized sheet, nipple dimension d 1 place of laterals. Product code: COLL d 1 miejsce odejść miejsce odejść 1 90 Ød1 Ø H 2 H d 1 H 1 H
113 T-pieces TSVL/TSV-45 XSVL/XSV-45 TSVL-45 TSVL-45 - T-piece with EPDM gasket and 45 branch Available upon request: 15, 30, 60. e.g. TSVL 15 - d 1 - d 3 XSVL-45 TSV-45 TSV-45 T-piece without gasket, with 45 branch Available upon request: 15, 30, 60. e.g. TSV 15 - d 1 - d 3 XSVL-45 X-pieces with EPDM gasket and 45 branch Available upon request: 15, 30, 60. e.g. XSVL 15 - d 1 - d 3 - d 4 XSV-45 X-pieces without gasket, with 45 branch Available upon request: 15, 30, 60. e.g. XSV 15 - d 1 - d 3 - d 4 Product code: Æd 3 TSVL-45 - aaa - bbb XSVL-45
114 T-pieces TSVL/TSV-45 XSVL/XSV-45 Æd 3 L L 2 TSVL/TSV XSVL/XSV weight [kg] ,4 0, ,4 0, ,5 0, ,5 0, ,6 0, ,7 0, ,6 0, ,7 0, ,8 0, ,9 1, ,6 0, ,7 0, ,8 1, ,9 1, ,9 1, ,6 0, ,7 0, ,8 1, ,9 1, ,0 1, ,0 1, ,7 0, ,8 0, ,9 1, ,0 1, ,0 1, ,1 1, ,2 1, ,8 0, ,9 1, ,0 1, ,0 1, ,1 1, ,2 1, ,3 1, ,4 1, ,0 1, ,1 1, ,2 1, ,2 1, ,3 1,6 Æd 3 L L 2 TSVL/TSV XSVL/XSV weight [kg] ,4 1, ,5 1, ,7 2, ,2 1, ,3 1, ,4 1, ,5 1, ,5 1, ,7 2, ,8 2, ,0 2, ,3 2, ,5 1, ,6 1, ,6 1, ,7 2, ,8 2, ,0 2, ,2 2, ,5 3, ,7 3, ,6 1, ,6 1, ,7 2, ,8 2, ,9 2, ,1 2, ,3 2, ,6 3, ,8 3, ,1 3, ,7 1, ,8 2, ,9 2, ,0 2, ,2 2, ,4 2, ,7 3, ,0 3, ,2 3, ,3 4,1
115 T-pieces TSVL/TSV-45 XSVL/XSV-45 Æd 3 L L 2 TSVL/TSV XSVL/XSV weight [kg] ,4 2, ,5 2, ,7 3, ,9 3, ,1 3, ,5 4, ,9 4, ,1 5, ,3 5, ,8 6, ,0 3, ,2 3, ,4 3, ,7 4, ,2 4, ,5 5, ,8 5, ,0 5, ,5 6, ,3 7, ,2 4, ,5 4, ,8 5, ,4 6, ,8 6, ,1 7, ,4 7, ,0 8, ,0 9, ,0 11, ,9 5, ,3 5, ,9 6, ,4 7, ,7 7, ,9 7, ,6 8, ,6 10, ,7 11, ,8 14, ,9 6,4 Æd 3 L L 2 TSVL/TSV XSVL/XSV weight [kg] ,5 7, ,0 7, ,4 8, ,6 8, ,4 9, ,4 11, ,6 12, ,7 14, ,1 16, ,9 7, ,5 8, ,9 8, ,1 9, ,9 10, ,0 11, ,2 13, ,3 14, ,8 16, ,8 18, ,8 8, ,2 9, ,5 9, ,3 10, ,4 12, ,7 13, ,8 15, ,3 17, ,3 18, ,2 19, ,5 13, ,9 14, ,0 15, ,6 17, ,4 19, ,0 21, ,0 24, ,4 26, ,6 28, ,1 33, ,5 15, ,7 17,3
116 T-pieces TSVL/TSV-45 XSVL/XSV-45 Æd 3 L L 2 TSVL/TSV XSVL/XSV weight [kg] ,4 19, ,4 22, ,0 24, ,3 26, ,8 28, ,0 30, ,8 35, ,7 41, ,5 19, ,3 21, ,5 24, ,3 26, ,7 29, ,3 31, ,7 33, ,7 38, ,8 44, ,8 50, ,9 23, ,3 26, ,3 29, ,5 32, ,6 34, ,0 36, ,3 42, ,6 47, ,9 54, ,0 62, ,2 35, ,4 39, ,5 41, ,2 43, ,3 50, ,4 57, ,6 65, ,6 74, ,2 85, ,6 38, ,0 42, ,3 45, ,2 47,7 Æd 3 L L 2 TSVL/TSV XSVL/XSV weight [kg] ,6 54, ,1 61, ,8 70, ,2 80, ,0 90, ,5 103, ,7 49, ,8 52, ,7 59, ,6 67, ,8 75, ,7 86, ,9 97, ,9 110, ,7 126, ,8 53, ,0 60, ,4 67, ,9 77, ,2 87, ,7 98, ,0 111, ,2 128, ,9 140, ,5 63, ,2 71, ,2 81, ,8 92, ,7 103, ,3 117, ,9 133, ,8 146, ,0 158,7
117 Y-pieces YSVL-45 YSVL-45 Y-pieces with EPDM gasket and 45 branch Available upon request: 15, 30, 60. e.g. YSVL-15- d 1 - d 3 - d 4 Please specify two angles and all dimensions when ordering. Product code: Æd 3 Æd 4 YSVL-45 - aaa - bbb - ccc Æd 3 Æd 4 L 2 weight rated rated [kg] , , , , , , , , , , , , , ,0 Æd 3 Æd 4 L 2 weight rated rated [kg] , , , , , , , , , , , , , , , , , , ,0
118 Y-pieces YSV-45 YSV-45 Y-pieces without gasket, with 45 branch Available upon request: 15, 30, 60. e.g. YSV-15- d 1 - d 3 - d 4 Please specify two angles and all dimensions when ordering. Product code: Æd 3 Æd 4 YSV-45 - aaa - bbb - ccc Æd 3 Æd 4 L 2 weight rated rated [kg] , , , , , , , , , , , , , ,0 Æd 3 Æd 4 L 2 weight rated rated [kg] , , , , , , , , , , , , , , , , , , ,0
119 Male couplings NSL NSL coupling with EPDM gasket is used for joining SPR ducts. Product code: Æd NSL - aaa R Æd L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,40
120 Male couplings NS NS coupling without gasket, used for joining SPR ducts. Product code: Æd NS - aaa Æd L weight rated [kg] R , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,40
121 Male couplings with gasket SNSL The SNSL with EPDM rubber can be used as flexible connection or as duct length compensator. SNSL can also be used to connect a exchanged segments of ventilation system. Product code: d L SNSL - aaa - bbb d nom L nom 8 L L , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,80 1 weight [kg]
122 Male couplings with gasket SNSL d nom L nom L , , , , , , , , , , , , , , , , , , , , , , , , , , ,65 weight [kg]
123 Female couplings MSF MSF female coupling, designed for joining fittings directly. Product code: Æd MSF - aaa Æd L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,60
124 Male - Female couplings with gasket SMSFL The SMSFL with EPDM rubber can be used as flexible connection or as duct length compensator. SMSFL can also be used to connect a exchanged segments of ventilation system. Product code: d L SMSFL - aaa - bbb d nom L nom L1 L , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,80 weight [kg]
125 Male - Female couplings with gasket SMSFL d nom L nom L , , , , , , , , , , , , , , , , , , , ,35 weight [kg]
126 Take-offs ILPRL ILPRL take-off with radius and EPDM gasket. Designed for installation in the walls of rectangular ducts. Product code: Æd ILPRL - aaa Æd r weight rated [kg] , , , , , , , ,70
127 Take-offs ILPR ILPR take-off with radius, without gasket. Designed for installation in the walls of rectangular ducts. Product code: Æd ILPR - aaa Æd r weight rated [kg] , , , , , , , ,60
128 Take-offs ILSL ILSL take-off with radius and EPDM gasket. Designed for installation in the walls of rectangular ducts. Æd weight rated [kg] 80 0, , , , ,08 Product code: Æd ILSL - aaa 160 0, , , , , , , , , , , , , , , , , , , , , , , ,40
129 Take-offs ILS ILS take-off without radius and gaskets. Designed for installation in the walls of rectangular ducts. Æd weight rated [kg] 80 0, , , , ,08 Product code: Æd ILS - aaa 160 0, , , , , , , , , , , , , , , , , , , , , , , ,40
130 Take-offs ILSF ILSF take-off with designed for installation in the walls of rectangular ducts. Product code: Æd ILSF - aaa d nom weight [kg] 80 0, , , , , , , , , , , , , , , , , , , , , , , , , , , , ,40
131 Angle take-offs ILSV-45 / ILSVL-45 ILSV-45 angle take-off without gasket. ILSVL-45 angle take-off with EPDM gasket. The angle take-off is designed for connecting round ducts to the surface of rectangular ducts. Connection is made at an angle of 45. Different angles are available upon request. Product code: ILSV-45 - aaa L L weight [kg] , , , , , , , , , , , , , , , , , , , , , , , , , ,00
132 Angle take-offs with mesh ASV-45 Angle take-off with mesh 45 is designed for terminating round ducts. Product code: ASV-45 - aaa d1 L weight [kg] , , , , , , , , , , , , , , , , , , , ,95 * ASV typically terminated with a male flange without gasket
133 Take-offs with mesh ILSN/ILSNL ILSN connection with a mesh is used as the termination of ventilation ducts. It is equipped with a mesh made of galvanized wire of 1,05 mm diameter and mesh size 12,7 x 12,7 mm protecting against external contaminations. It is made of galvanized sheet. Optionally stainless or aluminium version is available. Product code: ILSN 160 wielkość ød kod Æd Ød L L ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN ILSN
134 Flexible connectors ILA ILA Damper made of AMT balancing tape, with the part made of galvanised sheet metal being male. Product code: ILA - aaa L 1 L L weight rated [kg] Lengths available upon request: 130, 150 mm
135 Flexible connectors ILA-K ILA-K Damper made of AMT 45/75/45 balancing tape, with FLS flanges installed on both sides. Product code: ILA-K - aaa Æd ÆD Ød ØD Ød2 Ød3 n , , , , , , , , , , , , , , , , , , , , , ,5 16 L 1 L
136 End caps CSL CSL end cap with EPDM gasket for duct termination. Product code: CSL - aaa Æd weight rated [kg] 80* 0,10 100* 0,10 125* 0, , ,20 Æd 160 0, , , , , , , , , , , , , , , , , , , , , , ,70
137 End caps CS CSL end cap without gasket for duct termination. Æd weight rated [kg] 80* 0,10 100* 0,10 125* 0,10 Product code: Æd CS - aaa 140 0, , , , , , , , , , , , , , , , , , , , , , , , , ,80
138 Pressed multipurpose end cap CP CP multipurpose end cap for duct or fitting termination. Product code: Æd CP - aaa Æd H R weight rated [kg] , , , , , , , ,51
139 Fitting end cap CPF CPF end cap for fitting termination. Product code: Æd CPF - aaa Æd L weight rated [kg] , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,5
140 End caps CSN CSN end cap for fittings without EPDM gasket and no roller finishing and flanged edges. Product code: Æd CSN - aaa d nom weight [kg] 80 0, , , , , , , ,9
141 Setoffs ODSOL/ODSO ODSOL round setoff with EPDM gasket. ODSO round setoff without gasket. The ODSOL setoff is used to bypass obstructions to the air flow. L and H can be modified as required, depending on design needs. Product code: Æd ODSOL - aaa Æd e Æd L H weight rated [kg] L e Æd , , , , , , , , , , , , , , , , , , , , , , , , ,0 H
Access Products. Download Wentyle Download AlnorCAM Buy via B2B
Access Products We reserve the right to make changes in the dimensions and technical data products due to their continuous improvement About the System About the System Access products, such as access
More informationFlexible Ducts. Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie
Flexible Ducts Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie About the System About the System The flexible ducts
More informationIllustration no. 1 Dampers available in Alnor product offer
Dampers Illustration no. 1 Dampers available in Alnor product offer Air dampers are an important component of ventilation systems. Depending on their actual function, dampers are divided into: regulating
More informationVentilation duct prefabricated components
Download Wentyle Download AlnorCAM B2B ordering Ventilation duct prefabricated components ALNOR reserves the right to modify technical specifications in line with the policy of continuous product improvement.
More informationPrefabricated Ducts. Download Wentyle Download AlnorCAM Buy via B2B
Prefabricate Ducts We reserve the right to make changes in the imensions an technical ata proucts ue to their continuous improvement About the System About the System The prefabricate components help install
More informationPTS - Single-Blade Damper. Halton PTS. Single-Blade Damper
Halton PTS Single-Blade Damper Shut-off, adjustment, balancing or control damper Casing leakage classification: EN 1751, Class C Casing and damper blade made of galvanised steel Tightness classification
More informationUTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper
Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,
More information1mm GALVANIZED PIPE SYSTEM
1mm GALVANIZED PIPE SYSTEM Product group 1 A modular pipe system Download catalogue 1mm GALVANIZED PIPE SYSTEM Product group 1 v.en.04/2013 Content Assembly methods... 1-8 Pipes... 9-12 Bends... 13-14
More informationVentilation systems made of plastics
Download Wentyle Download AlnorCAM Buy via B2B Ventilation systems made of plastics The manufacturer reserves the right to make changes in the dimension measurements and technical specification of products
More informationCONTENTS ROUND FITTINGS AIR DIFFUSION PRODUCTS DAMPERS FLEXIBLE DUCTS
Product Catalogue CONTENTS ROUND FITTINGS 6 90 pressed bend B / BL 7 60 pressed bend B / BL 8 45 pressed bend B / BL 9 30 pressed bend B / BL 10 15 pressed bend B / BL 11 90 short pressed bend BKL 90 12
More informationACCESSORIES FOR DUCT FANS
FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.
More informationVOLUME CONTROL / REGULATING DAMPERS
VOLUME CONTROL / REGULATING S PRODUCT RANGE Model Range Includes A - Multi-Leaf. (Flanged - Rectangular Duct) B - Multi-Leaf. (Slip joint / Spigot - Rectangular Duct) C - Multi-Leaf. (Slip joint / Spigot
More informationNEW PRODUCTS HRANEC SHEET METAL INTRODUCES. FOR 2015! Call for. Pricing S P I R A L & O V A L M A N
HRANEC 724-437-2211 SHEET METAL INTRODUCES 2 NEW PRODUCTS Roof Ports systems are stocked for same day shipping, see page 4. FOR 2015! Call for Pricing O V A L M A N 724-437-2211 Made to order single wall
More informationSilencers. ALNOR systemy wentylacji. Download Wentyle Download AlnorCAM B2B ordering
Download Wentyle Download AlnorCAM B2B ordering 410 ANOR reserves the right to modify technical specifications in line with the policy of continuous product improvement. http://www.alnor.com.pl/produkty_pl/kanaly-i-ksztaltki-okragle.html
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationVolume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating
Volume Control Dampers Incorporating Series LF upvc-vcd 2.76 m 3 /hr/m 2 leakage at 50 Pa, over 70% better than required by Part L of Building Regulations Corrosion resistant, perfect for chlorinated atmospheres
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationProduct & Description Order Code Dimensions (mm)
1RD 100 X 350MM Ø100 L 350 1RD 100 X 1M Ø100 L 1000 Rigid Ducting PVC 1RD 100 X 2M Ø100 L 2000 1.0 2.8 6.2 1RD 100 X 3M Ø100 L 3000 1RD 125 X 350MM Ø125 L 350 1RD 125 X 2M Ø125 L 2000 0.4 1.4 3.8 1RD 150
More informationNORDFAB DUCTING CATALOGUE
NORDFAB DUCTING CATALOGUE C l i p p e d D u c t i n g THE WORLD S FASTEST DUCTING & FLANGED DUCTWORK Nordfab QF Clipped and FL Flanged ducting QF clipped and FL flanged ducting offers a complete range
More informationAFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)
AFA TS GmbH - Werner von Siemens Str.3 - D-72661 Grafenberg Copyright 2009 Tel.: +49(0)7123-97382-0 - Fax: +49(0)7123-97382-90 - E-Mail: mail@afa-ts.de Page 1-15 www.afa-ts.com Exhaust Extraction Systems
More informationRegulation and shut-off damper SPB and SPC
SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are
More informationMULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue
MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue 2 Table of contents Introduction 05 Square shut-off damper Product description: square shut-off damper Price list Test report according to DIN EN 1751 06
More informationUNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features
GE Sensing & Inspection Technologies UNIK 5000 Pressure Sensing Platform The UNIK 5000 is a high performance configurable solution to pressure measurement. The use of Druck silicon technology and analogue
More informationceiling swirl diffuser DQJ
ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...
More informationC O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S PERFORATED FACE DIFFUSERS P SERIES P SERIES PERFORATED FACE DIFFUSERS P SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application:
More informationTHE WORLD S FASTEST DUCTING
NORDFAB DUCTING CATALOGUE Quick-Fit C l i p p e d D u c t i n g THE WORLD S FASTEST DUCTING & FLANGED DUCTWORK Nordfab QF Clipped and FL Flanged ducting QF clipped and FL flanged ducting offers a complete
More informationTRANS-Quick System. ALNOR ventilation systems. Download Wentyle Download AlnorCAM Order via B2B platform
Download Wentyle Download AlnorCAM Order via B2B platform 914 The manufacturer reserves the right to amend product dimensions and technical data given the ongoing product http://www.alnor.com.pl/produkty_pl/kanaly-i-ksztaltki-okragle.html
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationDiffusion grilles for installation in ducts
L-02-1-09e Diffusion grilles for installation in ducts Type / Content Application Safety instructions Content Application Safety instructions 2 Realisation 3 Dimensions Installation Dimensioning 4 Quick
More informationSYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT
136 SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT Extraction kits for testing centres for cars, light commercial vehicles and heavy vehicles with manual or automatic return system Equipments
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More informationCONTROLS & ANCILLARIES ANCILLARIES COMMERCIAL & DOMESTIC TECHNIC AL INFORMATION ANCILLARIES ALL YOUR REQUIREMENTS FROM A SINGLE SUPPLIER.
ANCILLARIES COMMERCIAL & DOMESTIC ANCILLARIES ALL YOUR REQUIREMENTS FROM A SINGLE SUPPLIER. 424 029 2085 8200 ANCILLARIES COMMERCIAL & DOMESTIC BENEFITS EXTRACT GRILLES DIFFUSERS LOUVRES VOLUME & CONTROL
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationMechanical mixing box MBM
Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationAIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS
AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationVAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING
VAV/CAV BOXES COMMERCIAL BUILDINGS A guide to VAV/CAV, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk At Price TWA we believe
More informationFire/combustion gas damper EKO-JBL
Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationC O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CE SERIES CE SERIES LINEAR SLOT DIFFUSERS CE SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationDCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description
DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF
More informationFire/smoke damper EKO-JBG2
Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More informationExternal grilles USAV, USVN, USSV and SVN TECHNICAL DATA
External grilles, U, and TECHNICAL DATA 2 External grilles, U, and U External grilles are used as covering grilles in air supply and exhaust openings. and U are moulded of aluminium. and are deep drawn
More informationRound duct diffuser DBB-RR
Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationSINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationCombustion gas damper EKO-SRB
Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment
More informationChapter 1 Pipes and fittings PVC - PE
Chapter 1 Pipes and fittings PVC - PE Solvent weld fittings Threaded connections Ball valves & butterfly valves Page 1-20 Page 21-33 Page 34-37 Slide valves & check valves Solvents & sealants Tools Page
More informationSEMI RIGID THE PROFESSIONALS CHOICE
SEMI RIGID THE PROFESSIONALS CHOICE for efficient, high performance MVHR ductwork installations. SAP APPENDIX Q LISTED brookvent.co.uk FITTING OUTLINE THE PROFESSIONALS CHOICE for efficient, high performance
More informationContent - Silencers. Silencers for spiral systems. Silencers for rectangular systems
Silencer Catalog Content - Silencers General information on noise... 3 General information on sound attenuation... 4 Silencer specification... 7 2 Silencers for spiral systems Silencers for rectangular
More informationFire/combustion gas damper EKO-JBG
Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.
More informationAL-Maraj Central A/C Systems Accessories Mfg Co.
AL-Maraj is one of the renowned Manufacturer, Stockist and Supplier of all kinds of HVAC products, Ducting accessories, Pipe support system, Electro-mechanical and A/C Accessories in U.A.E since 2000.
More informationTechnical documentation
VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list
More informationNEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance
March 29 Iris Control Damper (ICD) NEW Iris Control Damper (ICD) For adjustment and measuring of airflow Features Quick and simple installation and maintenance Extended spigot connections 1% opening capacity
More informationParticle Filter Box FKU
Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air
More informationPRIMEX VENTING PRODUCTS AND ACCESSORIES
Index ACCESS PANELS... 14-15 DIFFUSERS CEILING AND SIDEWALL WG Series ADJUST-A-VENT... 14-2 WGX Series TRUE-FLOW VENT... 14-2 SQUEEZE ELBOW 90 EB4X90... 14-5 termination diffuser collars... 14-3 TRIM PLATEs
More informationTPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD
FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers
More informationC O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel
More informationCustom Metal Fabrication - HVAC Air Duct and Fittings
Custom Sheet Metal Metal Forming Accessories Hardware Supplies Custom Metal Fabrication - HVAC Air Duct and Fittings 4120 Ridgeway Drive - Unit 28 Mississauga - Ontario - L5L 5S9 Tel 905-624-3854 / 905-290-2334
More informationAccessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound
Halton TSR/TSS Swirl Diffuser Radial horizontal air supply Air velocity is effectively reduced due to high mixing effect Circular duct connection with gasket All sizes available as an adapted version for
More informationMarine Catalogue 2014
Photo copyright STX Finland Marine Catalogue Marine Catalogue 14 1 05.08.14 Fläkt Woods EN 14.05 All rights reserved. www.flaktwoods.com Marine Catalogue Content 3 Components Type BDE Uninsulated Type
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationVAV controller. TROX Auranor Norge AS. Telephone Fax
GB0814 11.18 LØV-R VAV controller New regulator handles larger working area Low noise level Pressure independent Short overall length High measurement accuracy Can be installed directly in bend Flexible
More informationVolume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper
Volume Control Dampers Incorporating Series HVC-VCD Excellent general purpose volume control damper Lightweight aluminium construction Fully protected linkage system positioned outside of airstream Very
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More information1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...
1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.
More informationFALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationFire/smoke damper EKO-SRBG1
Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More informationLinear Slot Diffusers Model Slot 20 & Model Slot 25
Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page
More informationIrisControlDamper. For Adjustment and Measuring of Airflow.
IrisControlDamper For Adjustment and Measuring of Airflow www.actionair.co.uk sales@actionair.co.uk Iris Control Damper (ICD) Quick, silent and efficient is the simple summary of the features of the Actionair
More informationAir distribution product
Air distribution product The company C.L.A. was established in 1975 as a manufacturer company of air conditioning system components. Among its customers: dealers, air handling units producers and fans
More informationCRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic
Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Provision for motorised regulation Quick connection
More informationClimate Recovery Duct System Technical Specifications
Climate Recovery Duct System Technical Specifications Climate Recovery (CR) Duct System Climate Recovery (CR) Duct System Overview The CR Duct System offers a complete, pre-insulated system for heating,
More informationPlenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.
About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV Constant- / variable
More informationDHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser
DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser
More informationEnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited
April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.
More informationTPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB
Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationLong Throw Nozzle WDA
Long Throw Nozzle WDA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationRound Duct System Model RR-Complete
Round Duct System Model RR-Complete Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...4
More informationEAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS
Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Rotatable discs % flexible distribution pattern Cleanable Adjustable slot for enhanced capacity Simple adjustment Used together
More informationApartment ventilation
GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationCustom Metal Fabrication - HVAC Air Duct and Fittings
Custom Sheet Metal Metal Forming Accessories Hardware Supplies Custom Metal Fabrication - HVAC Air Duct and Fittings 4120 Ridgeway Drive - Unit 28 Mississauga - Ontario - L5L 5S9 Tel 905-624-3854 / 905-290-2334
More informationFire Dampers Catalogue
Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in
More informationSDV Vane Swirl Diffusers
SDV Vane Swirl Diffusers SDVSA Square plate vane swirl diffuser (angled slot) SDVCA Circular plate vane swirl diffuser (angled slot) SDVSB Square plate vane swirl diffuser (normal slot) SDVCB Circular
More informationVAV Terminal Units SDS
VAV Terminal Units SDS VAV Terminal Units SDS STEKON SDS; controls the volume of conditioned air into an occupied space in response to a thermostat or Building Management System control signal with minimal
More informationInstallation: 4.b. Using Armaflex sheet insulation on pipes. Application to pipes. Application to fittings
4.b. Using Armaflex sheet insulation on pipes Application to pipes 1. Apply Armaflex Sheet Insulation on pipes larger than 5 IPS. Cut the sheet insulation to proper width, permitting it to fit loosely
More informationto obtain the specified voids due
ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311
More informationSelf Cleaning Suction Screen
Effective 1/1/09 WATERMASTER Self Cleaning Suction Screen All galvanized construction with a heavy duty steel body with #3 expanded metal steel lid covered by #8 mesh, 20 gauge stainless cloth screen.
More informationAir Handling Piping Systems
Air Handling Piping Systems ProVent - Compressed Air System - PP Vent Duct System www.asahi-america.com Table of Contents Table of Contents Product Specification... Page 350 SOCKET PIPE AND FITTINGS Pipe,
More informationDistributed by: BEST MATERIALS Ph: , Fax:
Distributed by: BEST MATERIALS Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.bestmaterials.com Email: Sales@BestMaterials.com Dektite Product Guide Flashings for Metal Roofs Dektite Original The
More informationEnergy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)
Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units
More informationHEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES
HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L HD SERIES MANUFACTURERS OF AIR/FIRE/SMOKE CONTROL PRODUCTS Product Description and Features Introduction The HD Series Multi-Leaf Volume
More informationSTRAW MULCHERS WITH BLOWER MOD: GA-110 SLS / GA-130 SLS
STRAW MULCHERS WITH BLOWER MOD: GA-110 SLS / GA-130 SLS 1 03-55-0129 MOTOR,S HOODS ASSY.. "STICKER INCLUDED" 1 2 03-55-0050 MUFFLEUR HOODS ASSY. 1 3 01-55-0056 ROUND TUB "STICKER INCLUDED" 1 4 NC01-65-0076
More information