Flexible Ducts. Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie
|
|
- Edith Summers
- 6 years ago
- Views:
Transcription
1 Flexible Ducts Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie
2 About the System About the System The flexible ducts serve as a complement to ventilation ductwork. They are used for joining a series of rigid sheet metal ducts air valves or plenum boxes. They are also used for distribution of warm air from the ventilation cap and in heat recovery systems. The ducts are suited for greater dimensions of the round components to make their installation easier. When completely stretched, the ducts are 3.5 or 10m long. Installation Guide Duct clipping should be started from cutting the protection casing with a knife or scissors. After drawing apart, the duct should be cut along the internal spiral, and then split up with combination pliers. Once pulled onto a fitting or an air diffuser, the duct should be fastened with a TKS tightening band, and then the outer casing is to be wrapped up in aluminium tape. Labelling ALNOR products are furnished with the construction industry s B sign and product codes according to their technical specifications contained in this catalogue. Benefits of Use Due to their flexibility, the ducts can be deployed in hardly accessible places of the building and when it is difficult to plan how to connect boxes to the suspended ceiling. With 10-metre sections you can save time, as you do not have to work with short sections, and 120cm large cartons make their handling and storage quite easy. With its 25mm thick mineral wool insulation and a perforated tube inside, the duct also serves as a silencer. Flexible ventilation ducts ALUDUCT AD-L, ALUDUCT AD-3, SONODUCT AD-L, SONODUCT PE AD-L and IZODUCT AD-3 have hygiene certificate HK/B/0100/01/2009
3 ALNOR FLEX AF-AL d 1 L rated [mm] ext [mm] length L [mm] weight [kg/pcs] The flexible round ducts are a result of spiralling profiled aluminium tape which is joined using a triple overlap lock. Packaging: 3rm sections, squeezed to mm. Flexibility rate:minimum duct bend radius is one and half diameters or so (R=1.5D) Temperature range: 30 C to +250 C Maximum humidity: 95 % Allowable static pressure: 2000 Pa Allowable static negative pressure: 1000 Pa Flow rates: Recommended operating speed: Maximum flow rate: Fire resistance: non-combustible do 7 m/s do 25 m/s Product code: AF-AL - aaa , , , , , , , , , , , , , , , , , , , , , , ,25
4 STAL FLEX AF-SN d 1 L rated [mm] ext [mm] length L [mm] The flexible round ducts are a result of spiralling profiled aluminium tape which is joined using a triple overlap lock. Packaging: 3rm sections Flexibility rate: Minimum duct bend radius is one and half diameters or so (R=2,5 D) Temperature range: 30 C to +500 C Maximum humidity: 95% Allowable static pressure: 2000 Pa Allowable static negative pressure: 1000 Pa Flow rates: Recommended operating speed: Maximum flow rate: Fire resistance: non-combustible to 7 m/s to 25 m/s Product code: AF-SN - aaa
5 ALNOR FLEX/STAL FLEX AF-AL, AF-SN Technical Data Pressure drop chart for straight sections Speed ducts m/s Losses depending on wire resistance R w diameter Volume V w m3/h
6 ALNOR FLEX/STAL FLEX AF-AL, AF-SN Technical Data Pressure drop chart for sections angled 90 and 45 flexion - 90 flexion - 45 Losses depending on direction change Losses depending on direction change Speed ducts W w m/s Speed ducts W w m/s Noise level in ALNOR FLEX i STAL FLEX ducts with standard diameters of 100mm to 300mm Speed ducts noise level db Noise level in db Speed ducts frequency in Hz Figure 1: Noise level in ALNOR FLEX and STAL FLEX ducts straight section frequency in Hz Figure 1: Noise level in ALNOR FLEX and STAL FLEX ducts section angled at 90 r = d
7 ALUDUCT AD-L ALAD-L d The ALUDUCT flexible duct is made of aluminium-polyester casing, reinforced with spirally wound steel wire. Packaging: 10rm sections, squeezed to 600mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.6 x diameter in mm. Temperature range: 20 C to C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Fire classification - E.g /A/06/MŻ The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-L Name: ALUDUCT-G AD-L Æd out allowable tolerance [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0 Product code: ALAD-L - aaa
8 ALUDUCT AD-3 ALAD-3 d The ALUDUCT flexible duct is made of aluminium casing, reinforced with spirally wound steel wire. Packaging: 10rm sections, squeezed to 800mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.6 x diameter in mm. Temperature range: 30 C to C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-3 Name: ALUDUCT-G AD-3 Product code: ALAD-3 - aaa Æd out allowable tolerance [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0
9 ALUDUCT ALAD-L, ALAD-3 Technical Data Pressure drop chart for straight sections Losses depending on wire resistance R w Pa/m Speed ducts m/s Volume V w m3/h
10 Flexible duct ALAD-HY-3 The ALAD-HY-3 flexible duct is made of multilayer aluminium and polyester. Additionally its inner surface is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALAD-HY-3 duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts.the ALA- D-HY-3 ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. circa 0,6 x diameter in mm). Range of temperature: from - 30 o C up to o C. Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Æd allowable tolerance [mm] out [mm] pressure [Pa] [mm] , , , , , , , , , , , , , , , , , , , , , ,0 Product code: ALAD-HY-3 - aaa
11 Flexible duct ALAD-HY-L Æd The ALAD-HY-L flexible duct is made of multilayer aluminium and polyester. Additionally its inner surface is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALAD-HY-L duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts.the ALAD-HY-L ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box. Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. circa 0,6 x diameter in mm). Range of temperature: from - 30 o C up to o C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Æd 1 Æd allowable tolerance [mm] out [mm] pressure [Pa] [mm] , , , , , , , , , , , , , , , , , , , , , ,0 Product code: ALAD-HY-L - aaa
12 SONODUCT AD-L ALSD-L d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-L insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx x diameter Temperature range: 30 C to C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Noise insulation: See the attached diagram. The duct is also available without perforation IZODUCT AD-L ALID-L Fire classification - E.g /A/07/MŻ The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-L Name: ALUDUCT-G AD-L Code: ALID-G-L Name: IZODUCT-G AD-L Æd ext allowable tolerance [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0 Product code: ALSD-L - aaa
13 SONODUCT PE AD-L ALSD-L PE d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-L insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. In addition, steam-tight polyester film is placed between the inner casing and the insulation. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx x diameter in mm. Temperature range: 20 C to C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Product code: ALSD-L PE - aaa Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0
14 SONODUCT AD-3 ALSD-3 d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-3 insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes, and 5rm sections, squeezed to 600mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx x diameter in mm.. Temperature range: 30 C to C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Noise insulation: See the attached diagram. The duct is also available without perforation. IZODUCT AD-3 ALID-3 Fire classification - E.g /A/06/MŻ The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-3 Name: ALUDUCT-G AD-3 Code: ALID-G-3 Name: IZODUCT-G AD-3 Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0 Product code: ALSD-3 - aaa
15 SONOLIGHT AD-L ALSDL-L d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-L insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific external diameter, i.e. approx x diameter in mm. Temperature range: 30 C to C Allowable negative pressure: Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Noise insulation: See the attached diagram. The duct is also available without perforation. IZOLIGHT AD-L ALIDL-L Fire classification - E.g /A/07/MŻ Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0 Product code: ALSDL-L - aaa
16 SONOLIGHT PE AD-L ALSDL-PE-L d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. In addition, steam-tight polyester film is placed between the inner casing and the insulation. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx x diameter in mm. Temperature range: 30 C to C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Product code: ALSDL-PE-L - aaa d 1 Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0
17 SONODUCT/SONOLIGHT Technical Data Noise attenuation curves The charts show noise levels for noise and heat insulated SONODUCT and SONOLIGHT ducts, depending on the section length: 500mm, 1000mm and 1500mm at a noise insulation thickness of approx. 25mm. Noise level db Noise level db Frequency en Frequency en Figure 1: noise level for SONODUCT/SONOLIGHT Noise insulation thickness Duct section length 25 mm 500 mm Figure 2: noise level for SONODUCT/SONOLIGHT Noise insulation thickness Duct section length 25 mm 1000 mm Noise level db Frequency en Figure 3: noise level for SONODUCT/SONOLIGHT Noise insulation thickness Duct section length 25 mm 1500 mm
18 IZODUCT/IZOLIGHT Technical Data Flow resistance chart for IZODUCT/IZOLIGHT ducts [Pa/m] [m] flow rate [m/s] diameter [mm] output [m3/h]
19 POLYDUCT POAD Æd Flexible duct POLYDUCT is made of 30 µm thick multilayer polyester.the whole duct is reinforced with spirally coiled steel spring wire. Flexible ducts POLYDUCT are recommended for ventilation and air-condition systems as well as for heating systems. Packing: 10 m long sections are packed in carton boxes. Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. from 0,6 x diameter in mm. Range of temperature: from - 30 C up to C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter.external diameter admissilble pressure allowance Product code: POAD - aaa typ Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,5
20 POLYIZODUCT POD d 1 Flexible duct thermally insulated with 25 or 50 mm thick mineral wool. Its internal jacket is made of 30 µm thick double-layer polyester. External jacket is made of 30 µm thick double-layer metalized polyester. Additionally between the internal jacket and the insulation there is steamproof foil. External jacket is reinforced with spirally coiled steel spring wire. Packing: 10 m long sections are packed in carton boxes. Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. from 0,8 x diameter in mm. Range of temperature: from - 30 C up to C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter.external diameter admissilble pressure allowance Product code: POD - aaa typ d 1 Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0
21 Flexible duct ALID-HY-3 Æd The ALID-HY-3 duct is thermally insulated with 25 mm thick mineral wool. Its external and internal jackets are made of multilayer aluminium and polyester. Additionally the internal jacket is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALID-HY-3 insulated duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts. The ALID-HY-3 insulation ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box. Flexibility degree (diameter of winding): Realtively to a given diameter, e.g. from 0,8 up to 1,1 x diameter in mm. Æd Æd allowable tolerance nom [mm] out [mm] pressure [Pa] [mm] , , , , , , , , , , , , , , , , , , , , , ,0 Range of temperature: from - 30 o C up to o C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Product code: ALID-HY-3 - aaa
22 Flexible duct ALID-HY-L Æd The ALID-HY-L duct is thermally insulated with 25 mm thick mineral wool. Its external and internal jackets are made of multilayer aluminium and polyester. Additionally the internal jacket is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALID-HY-L insulated duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts. The ALID-HY-L insulation ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box. Flexibility degree (diameter of winding): Realtively to a given diameter, e.g. from 0,8 up to 1,1 x diameter in mm. Æd Æd allowable tolerance nom [mm] out [mm] pressure [Pa] [mm] , , , , , , , , , , , , , , , , , , , , , ,0 Range of temperature: from - 30 o C up to o C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Product code: ALID-HY-L - aaa
23 Flexible duct PVC-A Æd COMBIAFS is produced from multi aluminium layer covered with a nonflammable and airtight PVC jacket, made of a 45 micron thickness. COMBIAFS is reinforced with high tension steel spring wire. Produced for discharging welding fumes and dense chemical gases where high mechanical resistance is required. COM-F flexible air ducts are recommended for ventilation, air-conditioning and heating systems. Packing: 10rm sections, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.6 x diameter in mm. Temperature range: 30 C C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Product code: PVC-A - aaa Æd Æd dozwolone tolerancja nom [mm] zew [mm] ciśnienie [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0
24 COMBIFLEX COM-F Æd The COMBIFLEX flexible duct is made of multilayer aluminium, tightly covered with non-flammable 110 micron PVC jacket. It s construction is reinforced with spiral steel spring wire. No vapour condensation is an advantage of this of ducts. Moreover the COMBIFLEX duct can be cleaned easily, is resistant to chemicals and UV radiation. The COMBIFLEX flexible ducts are recommended for ventilation and air-conditioning systems as well as for heating installations. Packaging: 10 m sections packed in cardboard boxes Degree of flexibility (winding diameter): relative to a specific diameter i.e. ca. 0,6 x diameter in mm. Temperature range: from 30 C to C Allowable negative pressure: depending on duct position. In straight sections 1/3 of transmitted pressure per the specific diameter can be assumed. Æd allowable tolerance nom [mm] out [mm] pressure [Pa] [mm] 80 82, , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,0 Product code: COM-F - aaa
25 PVC ducts PVC-R-DUCT, PVC-S-DUCT Æd typ A x B A zew x B zew length allowable [mm] [mm] [m] pressure [Pa] Round and rectangular PVC ducts are made of PVC plastics of 60 micron thickness, reinforced with steel wire. They are used in heating, cooling, ventilation and air-conditioning installations. Suitable for low and medium pressures. Due to high flexibility they are suitable for installations subject to continuous vibrations. PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT PVC-R-DUCT Packaging: 1m, 3m or 6 m sections, squeezed and packed in foil. Degree of flexibility (winding diameter): Relatively to a specific diameter i.e. ca. 0,6 x diameter in mm. A x B Temperature range: from 20 C to + 70 C Allowable pressure: Maximum allowed working pressure amounts to 2000 Pa Product code: PVC-R-DUCT - aaa - bbb dimension length typ A x B A zew x B zew length allowable [mm] [mm] [m] pressure [Pa] PVC-S-DUCT x110 57x PVC-S-DUCT x110 57x PVC-S-DUCT x110 57x PVC-S-DUCT x150 77x PVC-S-DUCT x150 77x PVC-S-DUCT x150 77x
26 Insulated ventilation duct sleeve SLVD-25/SLVD-50 d 1 SLVD flexible duct sleeve insulated with 25 mm or 50 mm glass mineral wool, coated with aluminum and polyester sleeve. SLVD sleeve is used for insulating round or oval ducts. SLVD sleeves are highly wear-resistant, do not transmit UV radiation and are resistant to chemicals. Packaging: 5rm sections in foil-wrapped rolls, packed in a cardboard box. Temperature range: From 30 C to C The product is also available in the GREEN variant for low organic compound emission Code: SLVD-G Product code: SLVD - aaa - bbb thickness insulation d 1 d 1 nom [mm] 80 82,0 d out [mm] , , , , , , , , , , , , , , , , , , , ,0
SEMI RIGID THE PROFESSIONALS CHOICE
SEMI RIGID THE PROFESSIONALS CHOICE for efficient, high performance MVHR ductwork installations. SAP APPENDIX Q LISTED brookvent.co.uk FITTING OUTLINE THE PROFESSIONALS CHOICE for efficient, high performance
More informationSilencers. ALNOR systemy wentylacji. Download Wentyle Download AlnorCAM B2B ordering
Download Wentyle Download AlnorCAM B2B ordering 410 ANOR reserves the right to modify technical specifications in line with the policy of continuous product improvement. http://www.alnor.com.pl/produkty_pl/kanaly-i-ksztaltki-okragle.html
More informationAccess Products. Download Wentyle Download AlnorCAM Buy via B2B
Access Products We reserve the right to make changes in the dimensions and technical data products due to their continuous improvement About the System About the System Access products, such as access
More informationCADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS
Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS Rectangular sound attenuator with connection to the outer casing, which also enables flange connection Excellent aerodynamic
More informationAir Excellent semi-circular semi-rigid ductwork. Technical data
Air Excellent semi-circular semi-rigid ductwork Technical data TABLE OF CONTENTS 1 INTRODUCTION... 3 2 SYSTEM OVERVIEW... 3 3 MATERIALS... 4 4 SEMI-CIRCULAR (SC) DUCTWORK... 5 4.1 AIR VELOCITY (m/s vs
More informationF LEXIBLE DUCT VERSIONS
Ref. no.: 2-16 F LEXIBLE DUCT VERSIONS fo r a ll n e e d s o f t h e v en ti t la i n o y g lo o n h c te Aero - ALUFLEX duct Aero - ALUSTRETCH duct Aero - ALUFLEX isolated duct Aero - ALUFLEX attenuator
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationSINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationDHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser
DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationHeat recovery units type GTDHR
GTDHR Double flux - 4 m3/h AC 23V type GTDHR Double flux heat recovery unit high efficiency 9%. The range consists of 5 sizes and 6 types for air flow from up to 4 m³/h. Application Ventilation and heat
More informationseries Silencers
series SK Silencers www.koolair.com Series SK 1 Silencers CONTENTS ASK-1 and ASK-2 Round Silencers Description 4 ASK-1 Overall Dimensions 5 ASK-2 Overall Dimensions 6 Selection Table and Weights 7 ASK-1
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationCircular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, aluminium construction Circular silencers, in rigid aluminium construction, for the reduction of noise in the
More informationNOVELIS OHLER Flexrohre For safety, comfort and flexibility...
Brighter ideas with aluminum NOVELIS OHLER Flexrohre For safety, comfort and flexibility...... our solutions travel throughout the world Table of contents TABLE OF CONTENTS 1 INTRODUCTION / PRODUCT OVERVIEW
More informationVAV Terminal Units SDS
VAV Terminal Units SDS VAV Terminal Units SDS STEKON SDS; controls the volume of conditioned air into an occupied space in response to a thermostat or Building Management System control signal with minimal
More informationFALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable
More informationto obtain the specified voids due
ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311
More informationRockLap H&V Pipe Sections
CONSTRUCTION TYPE: HVAC PIPEWORK JANUARY 2017 RockLap H&V Pipe Sections For rapid, efficient pipework insulation are strong lengths of pre-formed insulation with a one piece, factory applied foil facing
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationCircular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More informationATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.
ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationType CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION
Homepage > Products > Sound attenuators > Circular silencers > Type CS Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Circular silencers, in rigid aluminium construction,
More information1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...
1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.
More informationHigh Performance Fan Coils FCHG Genesis Series Horizontal
Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct
More informationCONTENTS ROUND FITTINGS AIR DIFFUSION PRODUCTS DAMPERS FLEXIBLE DUCTS
Product Catalogue CONTENTS ROUND FITTINGS 6 90 pressed bend B / BL 7 60 pressed bend B / BL 8 45 pressed bend B / BL 9 30 pressed bend B / BL 10 15 pressed bend B / BL 11 90 short pressed bend BKL 90 12
More informationAHF - Exhaust Grille. Halton AHF. Exhaust Grille
Halton AHF Exhaust Grille Large free area, high airflow rates with minimal pressure drop Integrated filter of class EU3 Reduced visibility through grille due to shaped horizontal vanes Sizes adapted to
More informationCircular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/
6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn
More informationBRC
------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationClimate Recovery Duct System Technical Specifications
Climate Recovery Duct System Technical Specifications Climate Recovery (CR) Duct System Climate Recovery (CR) Duct System Overview The CR Duct System offers a complete, pre-insulated system for heating,
More informationREK, LEK, ROK and LOK
REK, LEK, ROK and LOK Elegant and clear lined supply air diffusers for suspended ceilings. 06.6 REK, LEK, ROK and LOK Stylish supply air diffusers REK, LEK, ROK and LOK are designed for suspended ceilings
More informationMarine Catalogue 2014
Photo copyright STX Finland Marine Catalogue Marine Catalogue 14 1 05.08.14 Fläkt Woods EN 14.05 All rights reserved. www.flaktwoods.com Marine Catalogue Content 3 Components Type BDE Uninsulated Type
More informationTelephone Cables Fire Warning Cables
Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free
More informationPH SERIES SINGLE DUCT ATU PERFORMANCE DATA
PH SERIES SINGLE DUCT ATU PERFORMAE DATA The Performance Aire PH Series is the simplest and most widely used VAV terminal unit. Its basic components are an insulated sheet metal box, round inlet damper,
More informationACCESSORIES FOR DUCT FANS
FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.
More informationToppTube PA11 (Polyamide) page 4. ToppTube PA12 (Polyamide) page 5. ToppTube PA12HIPHL (Polyamide) page 6. ToppTube PUR 98A (Polyurethane) page 7
ToppTube PA11 (Polyamide) page 4 ToppTube PA12 (Polyamide) page 5 ToppTube PA12HIPHL (Polyamide) page 6 ToppTube PUR 98A (Polyurethane) page 7 ToppTube PE-LD (Polyethylene) page 8 ToppTube PE-LLD (Polyethylene)
More informationTPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD
FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers
More informationApartment ventilation
GB1250 04.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationType MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE
Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE
More informationAir diffuser system Model AUDIX -AW
Air diffuser system Model AUDIX -AW Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationFIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS
FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages
More informationMODULAR AIR HANDLING UNITS GAH SERIES
MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various
More informationNR series. Circular CAV air volume control terminals with system powered mechanical regulator
series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationVAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1
X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser
More informationIN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems
IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range
More informationDFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser
Halton DFA Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket Openable
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationTHE PRE-INSULATED COPPER PIPES FOR DURABLE AND EASY CONNECTION OF AIR CONDITIONING UNITS
THE PRE-INSULATED COPPER PIPES FOR DURABLE AND EASY CONNECTION OF AIR CONDITIONING UNITS Powered by TCPDF (www.tcpdf.org) Easy to install Compliant with common refrigerants like R410A & R407C Ensures aesthetical
More informationMechanical mixing box MBM
Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationSRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS
Ceiling mounted linear disc diffuser for supply air QUICK FACTS flexible spread pattern Facility for vertical spread Facility for simultaneous vertical/horizontal spread Large induction effect Suitable
More informationtechnical catalogue Revision 30/4/13 1
technical catalogue Revision 30/4/13 1 Index FLEXIBLE DUCT Page No. Metalised flexible duct 4 Metalised acoustic flexible duct 5 Flexible duct pressure drop table 6 PLASTIC GRILLES AND DIFFUSERS Plastic
More informationApartment ventilation
GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to
More informationDetailed Specifications & Technical Data
Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical
More informationDFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser
Halton DFB Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket All sizes
More informationTechnical documentation
VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list
More informationPSI Anti-Corrosion Tape
General information Technical specifications Requirement evaluation Application instructions Certificates PSI Anti-Corrosion Tape 8 Pipeline Accessories 85 The Systems PSI anti-corrosion tapes have been
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for applications where small, flexible and easy-touse arms are required. Nederman FX2 arms are made of lightweight anodized aluminium sections, with three adjustable,
More informationROOF FAN ROOFMASTER STEC
AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...
More information0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table
Type overview FSR with guide cables or rods Type key FSR P S 0 0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Cover panel without back-fold: S = small,
More informationTPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB
Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,
More informationProduct catalogue 2006
Product catalogue 006 welding, cutting and more www.kemper.de Protective welding equipment Welding curtains... 107-109 Welding strip curtains... 110-111 Welding protection strips... 11 Lateral sliding
More informationCompact Grille Model KG
Compact grille KG Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...3
More informationDCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser
Halton DCS Ceiling Diffuser DCS/C DCS/A DCS/N DCS/J DCS/P Horizontal air supply, suitable also for exhaust Modular construction with five different, interchangeable front panel options suited for modular
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationExhaust air diffuser HPKH + Plenum box ATTS
Exhaust air diffuser HPKH + Plenum box ATTS The HPKH is a quiet, ceiling-mounted exhaust air diffuser. The diffuser has an almost completely perforated diffuser plate. The slot height of the diffuser can
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More informationCONSTANTFLOW Volume Flow Controllers
5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationTD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans
IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester
More informationC2-2. Table of Contents DUAL DUCT TERMINAL UNITS
C2 UA UCT TERINA UNITS Table of Contents UA UCT TERINA UNITS This unit features a compact design for variable volume applications where blending of hot and cold air is not required. T This unit features
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationJVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6
1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators
More informationAir displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225
0,5 0,4 0,3 0,25 0,2 0,16 0,12 0,1 0,08 0,06 0,05 0,04 0,03 0,025 0,02 0,3 0,4 0,5 0,6 1 1,5 2 2,5 3 4 5 125 2 315 ir displacement diffusers - p 202 Diffusers with rotating nozzle - p 215 lum jet diffusers
More informationParts and characteristics
Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly
More informationHigh-speed roll-up doors. R Series
High-speed roll-up doors R Series R Series High speed roll-up doors are extremely economical door systems for interiors. The EFAFLEX high-speed doors differ from other doors through their enormously high
More informationTBV - Terminal Unit. Halton TBV. Terminal Unit
Halton TBV Terminal Unit Horizontal air supply, suitable also for exhaust Integrated rectangular balancing plenum with measurement and adjustment functions Effective sound attenuation Circular duct connection
More informationDOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug
DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant
More informationBenchTop Extraction Arm FX2
The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight
More information500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)
500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage
More informationFan - Powered Terminal Unit Series Flow
5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone
More informationRegulation and shut-off damper SPB and SPC
SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are
More informationAccess Door General Characteristics. RD Access Doors. GX Access Doors. LX Access Doors. RRD Access Doors for Round Ducts
Access Doors 58 61 64 67 70 74 77 78 79 80 81 82 83 84 85 Access Door General Characteristics RD Access Doors GX Access Doors LX Access Doors RRD Access Doors for Round Ducts IRD Insulated Access Doors
More informationPressure control damper ERPA
Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for
More informationVAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K
. X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for
More informationTRH - Plenum for diffusers. Halton TRH. Plenum for diffusers
Plenum for diffusers Halton reserves the right to alter products without notice 07/15 Plenum ensuring proper function of supply air ceiling diffuser and connecting to ductwork Flexibility for levelling
More informationPre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL
Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL Technical Data Power supply 230 VAC Power (@+10 C) 12 W/m Min. fuse (type C) 10 A
More informationTubing and Accessories
Section 7 Tubing and Accessories Inch Industrial Tubing...............................FIT-7-2 Metric Industrial Tubing.............................FIT-7-3 Inch D.O.T. Tubing.................................FIT-7-3
More information