found in the chemical industry, in offshore installations, in the automobile sector, in the aircraft industry and in shipyards.
|
|
- Eugene Neal
- 5 years ago
- Views:
Transcription
1 x-hand-maschienenleuch_gb.qxd H X N D P :15 Uhr L O S N D I Seite U1 C T O N - M C L P H O R I N G O U T C T D L M P S
2 x-hand-maschienenleuch_gb.qxd X - H N D :15 Uhr N D Seite 2 M C H I N L M P S Description These explosion-protected fluorescent lamps were designed especially for inspection and maintenance work in potentially explosive atmospheres, such as are found in the chemical industry, in offshore installations, in the automobile sector, in the aircraft industry and in shipyards. Due to the small dimensions combined with a high light output, these robust lamps are particularly well suited for use in confined spaces, inside machines and in silos, etc., as well as anywhere where a reliable, portable light source is needed. Together with the appropriate accessories (optional), these lamps can also, for example, be used at sampling openings or as level gauges, or they can be fitted to railings. When working in confined spaces, containers and silos with metallic materials, special attention shall be paid to the protection of persons in accordance with the installation requirements. Lamps for low-voltage operation (24V) or with an isolating transformer (TR version) are available for such applications. lternatively, earth-leakage circuit breakers with a rated tripping current of 10 m can also be used. The explosionprotected versions of these protection devices can be positioned in the immediate vicinity of the lamps. Due to the low surface temperatures, they may also be mounted Luminous intensity distribution curve d 2GD 1... (single lamp) in the immediate vicinity of combustible materials C 0 C90 l/cd/klm Luminous intensity distribution curve d 2GD 2... (twin lamp) Single and twin-lamp versions from 6 W to 13 W Rated voltage ranges 24/230 V lso available with transformer Robust protective tube made of polycarbonate Suited for use in gas and dust x-atmospheres With electronic ballast C 0 C l/cd/klm
3 XPLOSION-PROTCTD HND ND MCHIN LMPS pplication range The powerful, explosion-protected hand and machine lamps with bi-pin fluorescent lamps fulfil the requirements of TX directive 94/9/C. They are generally suited for use in potentially explosive gas atmospheres in Zones 1 and 2, as well as in potentially explosive dust atmospheres in Zones 21 and 22, and are approved for temperature class T6/T5 or surface temperatures up to 80 C. Machine lamps (marking M) are used for the local illumination of machines and parts thereof. They are also ideally suited for use Constructional features The explosion-protected hand and machine lamps feature an integrated electronic ballast (VG) and are available with one or two built-in fluorescent lamps. Depending upon the type, they are approved for various supply voltages. The light-transmitting, protective tube is made of impact-resistant polycarbonate and features a built-in reflector. The lamp caps are made of robust neoprene rubber. Versions Hand lamps (marking ) feature a grooved grip made of neoprene rubber with a metal, trumpet-shaped gland and a neoprene rubber end cap with hook for hanging up the lamp at the workplace. as level gauges. They feature a metal trumpet-shaped gland and two neoprene rubber caps. They can be mounted directly onto the machines with suitable clamps. Lamps with isolating transformer (marking TR) are particularly suited for the safe protection of persons. For this purpose there is a completely potted isolating transformer for the galvanic isolation of the lamp from the supply voltage in the power supply cable. 3 Type code d 2G/D 206 TR With optional isolating transformer for the protection of persons. Lamp output Number of illuminants M Hand lamp with electronic ballast Machine lamp electronic ballast 2G/D Category 2G/D: for potenially gasand dust atmospheres in Zone 1 and 2, 21 and 22 d Flameproof enclosure dm Flameproof enclosure with accessories in encapsulation COOPR CROUS-HINDS GMBH 3
4 ZON 1 ZON 2 ZON 21 ZON 22 XPLOSION-PROTCTD HND ND MCHIN LMPS d 2GD 208 d 2GD M 208 X-LMPS WITH LCTRONIC BLLSTS (VG) I 24 V C/DC I 4 B C Technical data 24 V C/DC Marking to 94/9/C II 2 G/D xplosion protection x d IIB Temperature class Surface temperature C-Type xamination Certificate SV 04 TX 0101 nclosure material Polycarbonate/luminium Rated voltage 24 V C/DC Ballast VG, integrated Degree of protection to N 529 IP 67 Insulation class II Permissible ambient temperature 20 C to +50 C Standard cable length 5 m cable 3 x 1 mm 2 without plug** Ordering details 24 V C/DC Type With fluor- Temp. Surface Lum. Dimensions Weight Order No. escent class temp. flux B C compl. lamps ca. lm in mm ca. kg d 2GD 106 1x6 W T6 80 C d 2GD 108 1x8 W T6 80 C d 2GD 206 2x6 W T6 80 C d 2GD 208 2x8 W T6 80 C d 2GD M 106 1x6 W T6 80 C d 2GD M 108 1x8 W T6 80 C d 2GD M 118 1x18 W T6 80 C d 2GD M 130 1x30 W T5 95 C d 2GD M 136 1x36 W T4 130 C d 2GD M 158 1x58 W T4 130 C d 2GD M 206 2x6 W T6 80 C d 2GD M 208 2x8 W T6 80 C **Optional: Other cable length, other cable quality, x-plug incl. mounting Dimensions in mm COOPR CROUS-HINDS GMBH 4
5 ZON 1 ZON 2 ZON 21 ZON 22 XPLOSION-PROTCTD HND ND MCHIN LMPS d 2GD 208 d 2GD M 208 X-LMPS WITH LCTRONIC BLLSTS (VG) I 230 V C/DC I 5 B C Technical data 230 V C/DC Marking to 94/9/C II 2 G/D xplosion protection x d IIB x dm IIB (TR) Temperature class Surface temperature C-Type xamination Certificate SV 04 TX 0101 nclosure material Polycarbonate/luminium Rated voltage 230 V C/DC Ballast VG, integrated Degree of protection to N 529 IP 67 Insulation class II Permissible ambient temperature 20 C bis +50 C Standard cable length 5 m cable 3 x 1 mm 2 without plug** Ordering details 230 V C/DC with isolating transformer Type With fluor- Temp. Surface Lum. Dimensions Weight Order No. escent class temp. flux B C compl. lamps ca. lm in mm ca. kg dm 2GD 106 TR* 1x6 W T6 80 C dm 2GD 108 TR* 1x8 W T6 80 C dm 2GD 113 TR* 1x13 W T5 95 C dm 2GD 206 TR* 2x6 W T6 80 C dm 2GD 208 TR* 2x8 W T6 80 C dm 2GD M 106 TR* 1x6 W T6 80 C dm 2GD M 108 TR* 1x8 W T6 80 C dm 2GD M 113 TR* 1x13 W T5 95 C dm 2GD M 206 TR* 2x6 W T6 80 C dm 2GD M 208 TR* 2x8 W T6 80 C dm 2GD M 213 TR* 2x13 W T5 95 C *...TR: Version with isolating transformer, potted, integrated in power supply cable **Optional: Other cable length, other cable quality, x-plug incl. mounting Dimensions in mm COOPR CROUS-HINDS GMBH 5
6 ZON 1 ZON 2 ZON 21 ZON 22 XPLOSION-PROTCTD HND ND MCHIN LMPS d 2GD 208 d 2GD M 208 X-LMPS WITH LCTRONIC BLLSTS (VG) I 230 V C/DC I 6 B C Technical data 230 V C/DC Marking to 94/9/C II 2 G/D xplosion protection x d IIB x dm IIB (TR) Temperature class Surface temperature C-Type xamination Certificate SV 04 TX 0101 nclosure material Polycarbonate/luminium Rated voltage 230 V C/DC Ballast VG, integrated Degree of protection to N 529 IP 67 Insulation class II Permissible ambient temperature 20 C bis +50 C Standard cable length 5 m cable 3 x 1 mm 2 without plug** Ordering details 230 V C/DC Type With fluor- Temp. Surface Lum. Dimensions Weight Order No. escent class temp. flux B C compl. lamps ca. lm in mm ca. kg d 2GD 106 1x6 W T6 80 C d 2GD 108 1x8 W T6 80 C d 2GD 113 1x13 W T5 95 C d 2GD 206 2x6 W T6 80 C d 2GD 208 2x8 W T6 80 C d 2GD M 106 1x6 W T6 80 C d 2GD M 108 1x8 W T6 80 C d 2GD M 113 1x13 W T5 95 C d 2GD M 118 1x18 W T6 80 C d 2GD M 130 1x18 W T5 95 C d 2GD M 136 1x36 W T4 130 C d 2GD M 158 1x58 W T4 130 C d 2GD M 206 2x6 W T6 80 C d 2GD M 208 2x8 W T6 80 C d 2GD M 213 2x13 W T5 95 C **Optional: Other cable length, other cable quality, x-plug incl. mounting Other voltage on request. Dimensions in mm COOPR CROUS-HINDS GMBH 6
7 ZON 1 ZON 2 ZON 21 ZON 22 XPLOSION-PROTCTD HND ND MCHIN LMPS F I X I N G - C C S S O R I S 7 KF Ordering details clamp with ball joint KF Type for Dimensions Weight Order No. KF 3 ca. 40 mm ca. 245 ca KF 4 ca. 50 mm ca. 250 ca KFV Ordering details double-clamp jaw isolated KFV Type for Dimensions Weight Order No. KFV 3 ca. 40 mm ca. 265 ca KFV 4 ca. 50 mm ca. 280 ca Ordering details permanent magnet PM 1 (adhesion 10 kg) Typ for Dimensions Weight Order No. PM 1 ca. 50 mm ca. 130 ca PM1 Ordering details permanent magnet PM 2 (adhesion 50 kg) Type for Dimensions Weight Order No. PM 2 ca. 40 mm ca. 190 ca PM 2 ca. 50 mm ca. 205 ca PM2 Ordering details suspension hook with ball joint KH Type for Dimensions Weight Order No. KH 3 ca. 40 mm ca. 172 ca KH 4 ca. 50 mm ca. 183 ca KH Ordering details spring clip F Type for Dimensions Weight Order No. F 3 ca. 40 mm ca. 62 ca F 4 ca. 50 mm ca. 78 ca F Ordering details special key for opening lamps Type for Dimensions Weight Order No. SCH mm ca. 115 ca SCH Dimensions in mm COOPR CROUS-HINDS GMBH 7
8 :15 Uhr Seite U /x/10.05/SL We reserve the right to make technical changes. Valid from October 2005 x-hand-maschienenleuch_gb.qxd Cooper Crouse-Hinds GmbH Neuer Weg Nord 49 D berbach Phone +49 (0) 62 71/ Fax +49 (0) 62 71/ Internet
Ordering details HL 43 d / ML 43 d / ML 50/60/70 d / ML 43/60 LED
.6 Ordering details HL 43 d / ML 43 d / ML 50//70 d / ML 43/ LED Ordering details Hand lamps Dimensions Type Lamp power Voltage Lamp cap Luminous flux Ø B Ø C Weight Order No. HL43d LED6 4 6 W LED 85-264
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationEV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology
LED technology for hazardous areas EV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology LED Technology for Zone 1/2 and 21/22 The efficient solution for your illumination
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationCEAG Products Main Catalogue Part 1 Chapter 1. Portable Ex-lighting
CEAG Products Main Catalogue Part Chapter Portable Ex-lighting ..2 EATON www.crouse-hinds.de Portable Ex-lighting Table of contents. General information on portable Ex-lighting.....4.2 Ex-torchlight Series
More informationOperating Instructions
Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationFHL. Ex d. Body in aluminium
Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More informationCROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights
CEAG Products Explosion protected floodlights CROUSE-HINDS SERIES PXLED - Power Floodlight Series for Hazardous Areas Explosion-protected LED floodlight series for Zone 1, 2, 21 and 22 Ex-Floodlight PXLED
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationCEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1
CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationEX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS
EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS 4 5 6 8 EX-CEILING LIGHT FITTINGS EX-PENDANT LIGHT FITTINGS 4.4 4.0 EX-FLOODLIGHTS EX-VESSEL LIGHT FITTING 4.8 4.46 0 ZONE / EX-PENDANT LIGHT FITTINGS
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationATEX. Pneumatic chain hoists. Pneumatic chain hoist model CPA ATEX INFO. Capacity kg. Features. Options. Applications
Pneumatic chain hoist model CPA ATEX 125-980 are characterized by high durability in a great industrial applications. The robust housing allows an easy transport. Features Working pressures 5-7 bar Rotating
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationEX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS
1 EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 2 ouse se-hin inds 20 08 - all righ ghts re serv rved C ou Co oper Cr 3 4 5 6 7 EX-CEILING LIGHT FITTINGS 5.41 8 EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationTable of contents INFO. Page. General information ATEX Pneumatic chain hoists ATEX Hand chain hoists ATEX Trolleys
ATEX 427 Table of contents Page General information on explosion protection. Some products from our standard range have been modified for use in potentially explosive atmospheres (areas). The products
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationSicherheit, auf die Sie sich verlassen können
Industrial light fittings Sicherheit, auf die Sie sich verlassen können Catalogue LED High Bay Light Fittings and Floodlights for Industrial Applications EATON 1 LED Lighting Solutions for Industrial Applications
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationellk 92 LED Light Fittings
CEAG Products Ex-Solutions LED Lighting ellk 92 LED Light Fittings Linear light fitting series with new LED module for hazardous areas Zone 1, 2, 21 and 22 www.crouse-hinds.de EATON 1.2.1 Ex-LED-Linear
More informationEX-FLUORESCENT LIGHT FITTINGS
1 EX-FLUORESCENT LIGHT FITTINGS 2 3 5 6 EX-LIGHT FITTING ellk 92... MAIN FEATURES EX-LIGHT FITTING ellk 92... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 92... EX-EMERGENCY LIGHT FITTING ellk 92...
More informationellk/m 92 LED 400/800
Explosion-protected Linear LED Light Fitting for Zone 1 and 21 1.1 ellk/m 92 LED 400/800 Linear LED Ex-light fittings ellk/m 92 LED 400/800 / ellk 92 LED 400/800 CG-S/NIB (Zone 1, 2, 21, 22) The efficient
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationCEAG Products Portable Ex-Solutions. Facilitate your Maintenance in Hazardous Areas. en-lighting portable solutions EATON 1
CEAG Products Portable Ex-Solutions Facilitate your Maintenance in Hazardous Areas en-lighting portable solutions EATON 1 Powering Business Worldwide You are challenged with increasing efficiency and flexibility,
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationEX-FLUORESCENT LIGHT FITTINGS
1 EX-FLUORESCENT LIGHT FITTINGS 2 Co oper Cr ouse se-hinds 200 - all righ ghts rese serv rved EX-LIGHT FITTING ellk 2... MAIN FEATURES 2.20 3 4 6 7 EX-LIGHT FITTING ellk 2... EX-POLE MOUNTED LIGHT FITTING
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationIHB Series High Bay LEDs
IHB Series High Bay LEDs (for light industrial applications indoor) The powerful moisture-proof series of high bay light fittings The energy saving IHB series high bay LED is resistant against humid environments
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected switchgear CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können GHG 981 Ex-Safety switch for zone 22 GRP, Stainless steel, and painted steel enclosures for harsh environments
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationST8V 21.5 W/ mm EM
ST8V 21.5 W/840 1500 mm EM SubstiTUBE Value Economic LED tubes for electromagnetic control gears Areas of application _ General illumination within ambient temperatures from 20 +45 C _ Corridors, stairways,
More informationLeading the way in hazardous areas Features EATON
.2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected
More informationStyle luminaires for the next generation
Style LED CG-S Headline Style luminaires for the next generation Greater efficiency and less maintenance than ever before: LED technology for upgrading Style LED CG-S The Style series: a reliable concept
More informationWolflite XT Rechargeable LED Handlamp
Wolflite XT Rechargeable LED Handlamp Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Wolflite XT Rechargeable Handlamp exploits advanced technology to deliver excellent performance,
More informationAVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips
AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationSubstiTUBE Advanced ST8-HA4
www.osram.com SubstiTUBE Advanced ST8-HA4 Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 54% by replacing 1.2 m T8 fluorescent
More informationDuraPro Hazardous Area Fluorescent
CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Type 3 UL 844 - Class I Div. 2 - Groups A, B, C, & D UL - Outdoor Marine
More informationExplosion-protected surface-mounting Thermostat ATH-Ex Series
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationControl Panels, Distribution Panels and Components
11 Control Panels, Distribution Panels and Components EEx d Enclosures in Light Metal or stainless steel Flexible modular design for combining enclosures Can be used in Zone 1 and Zone 2 in Zone 21 and
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationInternationally approved.
E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure
More informationFlameproof Alternator
Flameproof Alternator Models ASX-400, ASX-401 Application l For use in hazardous areas classified as Zone 1, Group IIB, T4 l Suitable for local ambient temperature range -30 C to +50 C l Designed as a
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationApparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components
E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More informationExplosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo
Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationControl and Terminal Box Type A21-**-*****
e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de
More informationTank Inspection Lights Series 6122
> For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de
More information1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light
.4 Ex-Searchlight series SEB 8.., SEB 9.. and SEB 0 (Zone, 2, 2, 22) Portable searchlights for harsh conditions The explosion-protected portable searchlight series SEB 8/9/0 provides a strong and reliable
More informationAPPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.
Haz HazMax Pinnacle/al APPLICATIONS Hazardous locations Watertight requirements Dusttight requirements Oil and gas exploration and production Waste water treatment plants Pipeline compressor / pumping
More informationFlameproof Alternators
Overview Standard automotive type alternators are a continuous potential source of ignition when operated in hazardous atmospheres where combustible concentrations of gas, vapor or dusts may exist. To
More informationFlameproof Enclosures
Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical
More informationBeam lights & conversion kits
.0 Overview... 81.1 Planete 2000... 82.2 Beamlite... 83.3 Gemini Junior... 84.4 EL40... 8. Conversion Kit... 86 Emergency lighting design handbook revision 4 dh_el_rev.4_eng July 2014 79 80 Emergency lighting
More informationSEALA. Dust & Moisture Proof Luminaire
SAA Dust & Moisture Proof uminaire SAA Dust & Moisture Proof SAA dust & moisture proof luminaire is Megalite state of the art design, for various indoor dusty and humid area lighting applications. High
More informationXPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS
XPF XPFMax Performer/al APPLICATIONS, II & III Division 1 explosive atmospheres High, mid & low bay Fuel dispensing facilities Paint booths Marine and watertight requirements Paint & formulation facilities
More informationSynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
SynergEX Panelboards Panelboards for Hazardous Locations Installation & Maintenance Information IF 1659 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION Read these operating instructions and all other
More informationFlameproof Alternator
Flameproof Alternator Installation, Operation and Maintenance Alternator Types ASX-400 ASX-401 CE242 (6) ASX_0210 DESCRIPTION Twelve pole rotating field coil type externally excited alternators designed
More informationLinear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationEXPLOSION-PROOF ELECTRIC WIRE ROPE HOIST BWX
The BWX electric wire rope hoists are the best as versatility and features, matching requirements of hazardous area. One single lifting speed or two lifting speeds are got with the application of inverter
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationTHE PERFECT REPLACEMENT
THE PERFECT REPLACEMENT CONVENIENT LED TECHNOLOGY FOR EASY REPLACEMENT OF HALOGEN LAMPS WITH REFLECTORS LEDSpot XT4 modules with heat sink and lens As the perfect replacement for halogen lamps,the new
More informationCirculation pumps BFP-ATEX-T3/T4
Circulation pumps BFP-ATEX-T3/T F ATEX - range of use: to zone 1 and zone 1 T3 to zone 1 and zone 1 T Low noise emission High vol. efficiency Optimum suction Gerotor principle Resistant to contamination
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationWith magnetic fixing With ON/OFF switch
7L Series - LED lamps 7L LED lamps for the cabinet Energy-saving (LED technology) Power consumption 5 W Luminous flux equivalent to a 95 W incandescent bulb Magnetic, screw or clip fixing With ON/OFF switch
More informationEVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More informationATX DPD Series Distribution Panelboards Flameproof
ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation
More informationThe Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.
E X - T E R M I N A L E N C L O S U R E S Stainless Steel Version for Zone and Zone 2 The enclosure range is an ATEX certified enclosure / termination solution for category 2 (Zone) application with an
More information